WorldWideScience

Sample records for disposable hypodermic needles

  1. Experiments with Disposable Hypodermic Syringes.

    Science.gov (United States)

    Clayton, G. T.; And Others

    1988-01-01

    Lists five experiments or demonstrations involving hypodermic syringes. The titles of experiments are Boyle's Law, Charles' Law, Atmospheric Pressure, Expansion of Gases, and Boiling at Reduced Pressure. Provides a list of materials, the typical data, and graphs where appropriate. (YP)

  2. Evaluating the advances and use of hypodermic needles in dentistry.

    Science.gov (United States)

    Boynes, Sean G

    2014-10-01

    Different injection techniques and patient management methodologies have been proposed to decrease the fear patients may have concerning dental needles. Dental providers should have an understanding of the technological advances, changes in techniques, and patient perceptions associated with the hypodermic needle. This article provides an overview of the pain perception process associated with dental injections. It reviews the two main sensory nerve fibers associated with injection pain and discusses needle properties as well as complications and adverse occurrences.

  3. Removal of Separated Endodontic K-File with the Aid of Hypodermic Needle and Cyanoacrylate

    Directory of Open Access Journals (Sweden)

    Luciana Maria Arcanjo Frota

    2016-01-01

    Full Text Available A wide range of accidents might happen during the treatment of the root canal system, where the instrument separation is one of the most unpleasant occurrences. Several techniques have been developed to facilitate the removal of the fragments; however, they generally require specific devices that not always are available to the clinician. The aim of this case report is to present a simple alternative technique to remove from the root canals manual instruments fractured during the treatment. The case has its outline based on a 31-year-old patient who sought the clinic to have her maxillary first left premolar rehabilitated. The clinic and radiographic examinations revealed the need of endodontic retreatment and the presence of a fragment of a K-file instrument localized at the apical third of the palatine canal. The retreatment was initiated by the removal of the obturation materials followed by several unsuccessful attempts to take out the fractured instrument. Hence, it was chosen to perform the fragment removal using a hypodermic needle and cyanoacrylate adhesive. The fragment easily came out, which reinforces the technique adopted as a safe, simple, and low cost mean to solve the problem of fractured instruments using only items already present in the endodontic arsenal.

  4. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  5. Influence of hypodermic needle dimensions on subcutaneous injection delivery - a pig study of injection deposition evaluated by CT scanning, histology, and backflow

    DEFF Research Database (Denmark)

    Ann Praestmark Juul, Kezia; Bengtsson, Henrik; Eyving, Bente

    2012-01-01

    BACKGROUND: Thinner and shorter needles for subcutaneous administration are continuously developed. Previous studies have shown that a thinner needle causes fewer occurrences of painful needle insertions and that a shorter needle decreases the occurrence of painful intramuscular injections. However......, little is known about local drug delivery in relation to needle length and thickness. This study aimed to compare deposition depth and backflow from three hypodermic needles of 3 mm 34G (0.19 mm), 5 mm 32G (0.23 mm), and 8 mm 30G (0.30 mm) in length and thickness. METHODS: Ex vivo experiments were...... depth, the bulk of the injection was in the subcutaneous tissue and did not propagate from subcutis into dermis. With the 8 mm 30G needle all injections apart from one intramuscular injection were located in the subcutaneous layer. The volume depositions peaked in 4-5 mm depth for the 3 mm 34G needle...

  6. The ergonomics of safe needle disposal following venous cannula ...

    African Journals Online (AJOL)

    QuickSilver

    PRIZE SUBMISSION. Southern African Journal of Anaesthesia & Analgesia - July 2003. 15. The ergonomics of safe needle disposal following venous cannula insertion ... jury per year. Again two studies have demonstrated that 40% of needlesticks occur during the actual procedure and almost 40% of injuries oc- cur during ...

  7. Patients’ Knowledge of and Practices Relating to the Disposal of Used Insulin Needles

    Directory of Open Access Journals (Sweden)

    Kerri T. Musselman, PharmD

    2010-01-01

    Full Text Available Objective: To determine (1 how patients currently dispose of used insulin needles, (2 whether patients were educated about disposal of their used insulin needles, and (3 who educated patients about the disposal of their used insulin needles.Methods: A self-administered questionnaire was designed for this study. The survey assessed patient knowledge about disposal of used insulin needles and the patient-reported source and location of education about disposal techniques. The questionnaire was administered to a convenience sample of patients from four locations in Richmond, Virginia. Any patient who used insulin, was at least 18 years old, and was willing to complete the survey was eligible for inclusion.Results: Fifty responses were received with 40% indicating that education had been received on the disposal of used needles. From that 40%, nurses were identified as the source of education 60% of the time and pharmacists 25% of the time. Approximately 50% of the respondents reported disposing of used needles directly in the trash when at home. While away from home, 22% reported placing used needles in the trash, and 38% took them home for disposal.Conclusion: Patients are not consistently educated regarding the proper disposal of used needles. Health care practitioners should play a larger role in educating patients about the potential risks of inappropriate needle disposal and appropriate disposal methods. Future research is still needed to understand fully the magnitude of the problems associated with inappropriate needle disposal by patients.

  8. Effect of needle brand, needle bevel grind, and silicone lubrication on contamination of joints with tissue and hair debris after arthrocentesis.

    Science.gov (United States)

    Waxman, Sarah J; Adams, Stephen B; Moore, George E

    2015-04-01

    To assess contamination of joints with tissue and hair debris after arthrocentesis. Experimental. Fetlock joint tissues (n = 6 horses). Soft tissue flaps including joint capsule were dissected from the dorsal aspect of fetlock joints of 6 anesthetized horses leaving an intact proximal base ("live" model) or with complete excision and immediate mounting to a wooden frame ("fresh" model). Needles were inserted through joint tissues and saline solution was flushed through them into tissue culture plate wells, and then examined for tissue and hair debris. Nine needle types were assessed; variables included needle brand, needle bevel grind, needle size, and silicone lubrication. No significant difference was detected between "live" and "fresh" models for hair or tissue contamination. Compared to 20 g hypodermic needles, 19 g lubricated and 19 g non-lubricated needles had a significantly greater odds ratio (OR) for hair contamination. Nineteen-gauge non-lubricated needles had a significantly greater OR for hair contamination than 19 g lubricated needles. No significant differences in ORs were identified between type of needle bevel grind, brands of disposable hypodermic needles, or brands of spinal needles for hair or tissue contamination. Nineteen-gauge needles significantly increase the risk of joint contamination with hair compared to 20 g needles; non-lubricated 19 g needles have the greatest risk. All other needle types tested in this study have similar risks for tissue and hair contamination after arthrocentesis. © Copyright 2014 by The American College of Veterinary Surgeons.

  9. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Lamb shank, which has complexity of tendon, fascia, and bone , was used to mimic human tissue. The needles (n=10) were stressed in the tissue substitute...Synthetic tissues have been used in other studies11 but are too simplistic and do not mimic human tissue since they do not have muscle, fascia or bone ...They also deposit a sticky , oily residue on the acupuncture needles that is difficult to remove before viewing under a microscope11. Due to lack

  10. Utilization of No-Kor needles for slit-micrografting.

    Science.gov (United States)

    Brandy, D A; Meshkin, M

    1994-05-01

    This article introduces the No-Kor vented needle as an excellent tool for micrograft recipient site development. To show that No-Kor vented needles are better than conventional hypodermic needles (with and without dilators) and Bard Parker blades for micrograft recipient site development. Comparisons with hypodermic needles (with and without dilators) and Bard Parker blade incisions are made. When compared with hypodermic needles (with and without dilators, the No-Kor needles show less scarring, allow easier placement, take less surgical time, and are less expensive. When compared with Bard Parker blade incisions, the No-Kor needles demonstrate less scarring, more precision, and less expense. The No-Kor vented needle is an excellent tool for the development of micrograft recipient sites. It demonstrates advantages over both hypodermic needles and Bard Parker blades.

  11. Development of a three-microneedle device for hypodermic drug delivery and clinical application.

    Science.gov (United States)

    Fukamizu, Hidekazu; Fujiwara, Masao; Kim, Taishi; Matsushita, Yuki; Tokura, Yoshiki

    2012-08-01

    There is a potential use for intradermic or hypodermic drug delivery in skin surgery or aesthetic surgery. Hypodermic delivery with the use of a noninvasive device can be a more useful, reliable, and effective administration route to obtain higher compliance. The authors developed a microneedle device composed of three fine needles (three-microneedle device). The tip of each needle was fabricated with a bevel angle to release a drug broadly into the tissue in a horizontal fashion. In this study, the authors investigated the usefulness of this newly developed three-microneedle device for hypodermic liquid injection, focusing on the optimum insertion depth and the diffusion of injected materials to the tissue. The authors also assessed the efficacy of and patient satisfaction with three-microneedle device injections of botulinum toxin type A for wrinkle reduction in patients with glabellar rhytides. The three-microneedle device yielded consistent results in hypodermal diffusion. On India ink diffusion test and ultrasonographic imaging, three-microneedle device injection showed a broad diffusion in horizontal extension, as compared with usual 31-gauge needle injection. The efficiency and satisfaction of the patients receiving botulinum toxin type A with the three-microneedle device were highly rated. Three-microneedle device delivery enables accurate and broad diffusion of injected substances, thus reducing the total dose and/or injection number of drugs. Therapeutic, IV.

  12. Hypodermic self-insemination as a reproductive assurance strategy.

    Science.gov (United States)

    Ramm, Steven A; Schlatter, Aline; Poirier, Maude; Schärer, Lukas

    2015-07-22

    Self-fertilization occurs in a broad range of hermaphroditic plants and animals, and is often thought to evolve as a reproductive assurance strategy under ecological conditions that disfavour or prevent outcrossing. Nevertheless,selfing ability is far from ubiquitous among hermaphrodites, and may be constrained in taxa where the male and female gametes of the same individual cannot easily meet. Here, we report an extraordinary selfing mechanism in one such species, the free-living flatworm Macrostomum hystrix. To test the hypothesis that adaptations to hypodermic insemination of the mating partner under outcrossing also facilitate selfing, we experimentally manipulated the social environment of these transparent flatworms and then observed the spatial distribution of received sperm in vivo. We find that this distribution differs radically between conditions allowing or preventing outcrossing, implying that isolated individuals use their needle-like stylet (male copulatory organ) to inject own sperm into their anterior body region, including into their own head, from where they then apparently migrate to the site of (self-)fertilization. Conferring the ability to self could thus be an additional consequence of hypodermic insemination, a widespread fertilization mode that is especially prevalent among simultaneously hermaphroditic animals and probably evolves due to sexual conflict over the transfer and subsequent fate of sperm.

  13. 21 CFR 880.5570 - Hypodermic single lumen needle.

    Science.gov (United States)

    2010-04-01

    ... 880.5570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use... an intravascular administration set. (b) Classification. Class II (performance standards). ...

  14. Needles and Other Sharps (Safe Disposal Outside of Health Care Settings)

    Science.gov (United States)

    ... sharps disposal container) in the household or public trash cans or recycling bins, and never flush them down the toilet. This puts trash and sewage workers, janitors, housekeepers, household members, and ...

  15. The Hydrodynamics of Needle-Free Intradermal Jet Injection

    Science.gov (United States)

    Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate

    2017-11-01

    Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.

  16. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  17. Migration pathways of hypodermically injected technetium-99 m in dogs

    International Nuclear Information System (INIS)

    Kovacs, F.M.; Mufraggi, N.; Garcia, A.; Pavia, J.; Giralt, I.; Piera, C.; Setoain, J.; Garcia, F.; Prandi, D.; Gotzens, V.

    2000-01-01

    Hypodermic injection of technetium-99 m ( 99 m TC-pertechnetate) at points of low electrical resistance give rise to rapid, longitudinal, and progressive diffusion of the radioactive tracer. We assessed the effect of cutaneous incisions that did not intersect the migration trajectory of 99 m Tc-pertechnetate and the re-establishment of pathways after the suture of incisions that intersected the migration trajectory. Linear and rapid migration of 99 m Tc-pertechnetate was not altered or prevented by incisions that did not intersect the migration pathway. Different patterns of 99 m Tc-pertechnetate spread were found when incisions intersected the radioactive pathways until restoration of the normal migration pathway observed in undamaged skin occurred. In all experiments in which migration of 99 m Tc-pertechnetate was observed, lavage of surgical wounds was followed by disappearance of the 99 m Tc-pertechnetate migration observed around the suture. Linear migration of the tracer was not observed when the incision was left uncovered, filled with petroleum jelly, or with a solid silicone sheet, but it was seen when non-sutured incisions were filled with transonic or silicone gel or covered with a solid silicone sheet parallel to the cutaneous plane. These data show that after a cutaneous incision that intersected the diffusion trajectory of the radioactive tracer, linear migration of 99 m Tc-pertechnetate hypodermically injected at points of low electrical resistance was restored before healing of the cutaneous incision and was independent of incisions made on the skin not overlying the radioactive pathway. A mechanism similar to that of capillary electrophoresis is suggested to explain the hypodermic diffusion of inert particles through specific and constant linear pathways. (orig.)

  18. Spread of fluid: Role of tip configurations in needles

    DEFF Research Database (Denmark)

    Gomes, Silvana; Drakidis, Alexandros Dimitrios; Silva, Patricia

    2017-01-01

    data were obtained after injecting 0.3 mL of fluid into a foamed polymer model with a velocity of 2 mm/s. The spread area and the depth were determined for 3 different types of hypodermic needles: Single channel needles with bevel tip and blunt tip and a needle with conical tip and 3 internal channels......During the injection of a fluid in a tissue model, the fluid might be affected by the needle tip configuration and the number of channels. Thus, the objective of the present work is to observe the influence of different needle tips and number of channels on the spread of a fluid. Fluid distribution...

  19. The mystery of the occluded port that allowed blood withdrawal: is it safe to use standard needles to access ports? A case report and literature review.

    Science.gov (United States)

    Cataldo, Rita; Costa, Fabio; Vitiello, Michelangelo; Brescia, Fabrizio; Proscia, Paola; Falco, Clementina; Carassiti, Massimiliano

    2014-04-01

    A frequent complication of totally implantable central venous access devices (TIVADs) is withdrawal occlusion. We describe a case of rare dysfunction of TIVADs: blood withdrawal was possible, whereas infusion was not. A further investigation demonstrated that during infusion, a silicone core, probably produced by hypodermic needle puncture, occluded the reservoir outlet hole. The silicone septum puncture by standard needles instead of non-coring ones may reduce the device effectiveness and expose patients to serious complications. © 2013 Wiley Periodicals, Inc.

  20. Complete prevention of blood loss with self-sealing haemostatic needles

    Science.gov (United States)

    Shin, Mikyung; Park, Sung-Gurl; Oh, Byung-Chang; Kim, Keumyeon; Jo, Seongyeon; Lee, Moon Sue; Oh, Seok Song; Hong, Seon-Hui; Shin, Eui-Cheol; Kim, Ki-Suk; Kang, Sun-Woong; Lee, Haeshin

    2017-01-01

    Bleeding is largely unavoidable following syringe needle puncture of biological tissues and, while inconvenient, this typically causes little or no harm in healthy individuals. However, there are certain circumstances where syringe injections can have more significant side effects, such as uncontrolled bleeding in those with haemophilia, coagulopathy, or the transmission of infectious diseases through contaminated blood. Herein, we present a haemostatic hypodermic needle able to prevent bleeding following tissue puncture. The surface of the needle is coated with partially crosslinked catechol-functionalized chitosan that undergoes a solid-to-gel phase transition in situ to seal punctured tissues. Testing the capabilities of these haemostatic needles, we report complete prevention of blood loss following intravenous and intramuscular injections in animal models, and 100% survival in haemophiliac mice following syringe puncture of the jugular vein. Such self-sealing haemostatic needles and adhesive coatings may therefore help to prevent complications associated with bleeding in more clinical settings.

  1. Needle autopsy

    OpenAIRE

    Philip Davis Marsden

    1997-01-01

    Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsi...

  2. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  3. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  4. Observation of the hypodermic fatty layer of the human torso by computed tomography method

    International Nuclear Information System (INIS)

    Matsuyama, Yoko; Inokuchi, Seiichiro; Suzuki, Masataka

    1984-01-01

    CT images were taken at 7 different longitudinal levels of the torso, and three different body types, which were defined by the Rohrer Index, were discussed. Differences between the sexes were also discussed. 1) Total cross-sectional area: In males, values showed maximum at 2 levels (mid-point of sternum, xiphoid) among 7 levels; and, for females, 2 maximal values appeared at the mid-point of the sternum level and the level of the pubic symphysis. Values at the umbilicus level were smallest in both sexes. 2) Areas of hypodermic fatty layer: Here, the values for males were maximal at the umbilicus level, next largest were found at the lower abdominal level. For females, however, the maximal values appeared at the pubic symphysis and lower abdominal levels and values for the umbilicus level followed in magnitude. 3) Hypodermic fatty layer area ratios to those of the total cross-sectional area: Values here were largest at the umbilicus level in both sexes. For males, the ratio at the lower abdominal level and at the pubic symphysis level followed in this order: For females, the order of magnitude of values was reversed between those two ratios. The most minimal ratio appeared at the level of the xiphoid in both sexes. A tendency towards higher ratios in females than in males was seen at all 7 levels for bodies of the A-type. This was seen, however, only at levels below the upper abdomen for bodies of the C-type, and at all levels, except the umbilicus and lower abdomen, for bodies of the D-type. 4) Thickness of the hypodermic fatty layer: The maximal values in this layer appeared at point F for the superior border, mid-point and xiphoid of sternum levels. For the upper abdominal level, maximal values appeared at point A, and for the umbilicus level, at point D. They were all found at point C for the lower abdominal level and at point A for the pubic symphysis level. (J.P.N.)

  5. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  6. Preventing the dental needle prick injury (DNPI) : a new approach to ...

    African Journals Online (AJOL)

    ... used dental needles. This paper introduces a technique of discarding the used dental needle in a safe manner which can reduce the risk of percutaneous injuries to dentists and their support staff and health care workers involved in medical waste disposal leading to safe incineration. Keywords: dental needle, prick, injury ...

  7. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  8. Cadmium induces hypodermal periderm formation in the roots of the monocotyledonous medicinal plant Merwilla plumbea.

    Science.gov (United States)

    Lux, Alexander; Vaculík, Marek; Martinka, Michal; Lisková, Desana; Kulkarni, Manoj G; Stirk, Wendy A; Van Staden, Johannes

    2011-02-01

    Merwilla plumbea is an important African medicinal plant. As the plants grow in soils contaminated with metals from mining activities, the danger of human intoxication exists. An experiment with plants exposed to cadmium (Cd) was performed to investigate the response of M. plumbea to this heavy metal, its uptake and translocation to plant organs and reaction of root tissues. Plants grown from seeds were cultivated in controlled conditions. Hydroponic cultivation is not suitable for this species as roots do not tolerate aquatic conditions, and additional stress by Cd treatment results in total root growth inhibition and death. After cultivation in perlite the plants exposed to 1 and 5 mg Cd L(-1) in half-strength Hoagland's solution were compared with control plants. Growth parameters were evaluated, Cd content was determined by inductively coupled plasma mass spectroscopy (ICP-MS) and root structure was investigated using various staining procedures, including the fluorescent stain Fluorol yellow 088 to detect suberin deposition in cell walls. The plants exposed to Cd were significantly reduced in growth. Most of the Cd taken up by plants after 4 weeks cultivation was retained in roots, and only a small amount was translocated to bulbs and leaves. In reaction to higher Cd concentrations, roots developed a hypodermal periderm close to the root tip. Cells produced by cork cambium impregnate their cell walls by suberin. It is suggested that the hypodermal periderm is developed in young root parts in reaction to Cd toxicity to protect the root from radial uptake of Cd ions. Secondary meristems are usually not present in monocotyledonous species. Another interpretation explaining formation of protective suberized layers as a result of periclinal divisions of the hypodermis is discussed. This process may represent an as yet unknown defence reaction of roots when exposed to elemental stress.

  9. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    Science.gov (United States)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  10. Dynamic control of needle-free jet injection.

    Science.gov (United States)

    Stachowiak, Jeanne C; Li, Thomas H; Arora, Anubhav; Mitragotri, Samir; Fletcher, Daniel A

    2009-04-17

    Many modern pharmaceutical therapies such as vaccines and macromolecular drugs benefit from transdermal delivery. Conventional transdermal drug delivery via hypodermic needles causes pain, non-compliance, and potential contamination. Alternative transdermal strategies that deliver drugs in a quick, reliable, painless, and inexpensive way are needed. Jet injectors, which deliver drugs through the skin using a high-speed stream of liquid propelled by compressed springs or gasses, provide a needle-free method of trandermal drug delivery. However, poor reliability as well as painful bruising and bleeding characterize these devices, due in part to the high and constant jet velocity with which drugs are delivered. Toward improved reliability and reduced pain, we have developed a jet injector capable of dynamic control of jet velocity during a single injection pulse. Using this device, we demonstrate that temporal control of jet velocity leads to independent control of penetration depth, by adjusting time at high velocity, and delivered dose, by adjusting time at low velocity, in model materials. This dynamic control of jet velocity creates the potential for better control of needle-free injections, as demonstrated through injection studies on whole ex vivo human skin samples.

  11. Efficacy of Tuohy Needle in Oocytes Collection from Excised Mare Ovaries

    Directory of Open Access Journals (Sweden)

    F. Cremonesi

    2010-01-01

    Full Text Available Two methods have been described to recover oocytes from equine follicles in excised ovaries: aspiration and scraping. Aim of this work was to develop an effective method for collecting equine oocytes using Tuohy needle and comparing this technique to aspiration and scraping, with or without tunica albuginea removal. This hollow hypodermic needle, usually employed for inserting epidural catheters, is designed with a slightly curved tip, shaped similar to a small curette. In unpeeled ovaries, the recovery rates of Tuohy needle group was higher (<.05 than in the 16 g needle aspiration and in the scraped ovaries (57% versus 36% and 47% while the rate of cumulus-intact oocytes was higher than aspiration (46.9% versus 39.36% but lower than scraping (46.97% (<.001. In unpeeled ovaries there was significant difference in maturation rate of oocytes recovered by Tuohy needle in respect to peeled ovaries (58.54% versus 50.17%, resp.. Combination of aspiration and scraping by Tuohy needle allows a faster and reliable collection of oocytes suitable for horse IVM.

  12. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  13. Evidence for costs of mating and self-fertilization in a simultaneous hermaphrodite with hypodermic insemination, the Opisthobranch Alderia willowi.

    Science.gov (United States)

    Smolensky, Nicole; Romero, Melissa R; Krug, Patrick J

    2009-04-01

    Simultaneous hermaphrodites offer the chance to study antagonistic coevolution between the sexes when individuals function in both roles. Traumatic mating by hypodermic insemination has repeatedly evolved in hermaphroditic taxa, but evidence for the fitness costs of such male-advantage traits is lacking. When reared in isolation, specimens of the sea slug Alderia willowi (Opisthobranchia: Sacoglossa) initially laid clutches of unfertilized eggs but 4 days later began self-fertilizing; this is only the third report of selfing in an opisthobranch. Hypodermic insemination may allow selfing in Alderia if penetration of the body wall bypasses internal mechanisms that promote outcrossing. Selfing specimens and slugs reared in pairs had reduced fecundity compared to isolated slugs laying unfertilized clutches, suggesting that hypodermic insemination imposes a cost of mating. Egg production increased for field-caught slugs separated after mating compared to slugs held in pairs, a further indication that accessibility to mates imposes a fitness cost to the female function. Such antagonism can confer a competitive advantage to slugs mating in the male role but diminish reproduction in the female role among hermaphrodites capable of long-term sperm storage. Alderia willowi is also a rare case of poecilogony, with adults producing either planktotrophic or lecithotrophic larvae. Our rearing studies revealed that most slugs switched between expressed development modes at some point; such reproductive flexibility within individuals is unprecedented, even among poecilogonous species.

  14. Self-fertilization, sex allocation and spermatogenesis kinetics in the hypodermically inseminating flatwormMacrostomum pusillum.

    Science.gov (United States)

    Giannakara, Athina; Ramm, Steven A

    2017-05-01

    The free-living flatworm genus Macrostomum is an emerging model system for studying the links between sex allocation, sexual selection and mating system evolution, as well as the underlying developmental and physiological mechanisms responsible for wide intra- and inter-specific variability in reproductive phenotypes. Despite compelling comparative morphological evidence of sexual diversity, detailed experimental work on reproductive behaviour and physiology in Macrostomum has so far been largely limited to just two species, M. lignano and M. hystrix , an obligate and a preferential outcrosser, respectively. In this study, we establish that a third species, M. pusillum , exhibits a combination of reproductive traits strikingly different from both of its congeners. Unlike M. lignano , we demonstrate that M. pusillum does not adjust sex allocation or the speed of spermatogenesis to the prevailing social group size. M acrostomum pusillum 's relatively simple sperm morphology likely explains the short spermatogenesis duration we report, and is linked to a hypodermically inseminating mode of fertilization, which we show also means that these worms are capable of self-fertilization. Surprisingly, and unlike M. hystrix , selfing in isolated worms commences after only a short (if any) delay compared with the onset of reproduction in grouped individuals, with little evidence of differential inbreeding depression in 'isolated' progeny. These combined results suggest that, in nature, M. pusillum may be regularly selfing, in contrast to the congeners studied to date. Our findings highlight the rapid and correlated evolution of reproductive traits, and reinforce the utility of the genus Macrostomum for understanding the evolutionary and developmental mechanisms responsible for this diversity. © 2017. Published by The Company of Biologists Ltd.

  15. Temno biopsy needle

    International Nuclear Information System (INIS)

    Quinn, S.F.; Demlow, T.; Dunkley, B.

    1991-01-01

    This paper reports on the Temno needle which is spring-activated biopsy needle that is being marketed to radiologists as a needle that can obtain histologic cores. One hundred fifteen biopsy procedures were performed; biopsy sites included liver; retroperitoneum; lung, mediastinum, and pleura; musculoskeletal structures; thyroid; abdominal and pelvic masses; and pancreas. The needle sizes included 21-gauge, 18-gauge, 16-gauge, and 14-gauge needles. The biopsy procedures were diagnostic in 87.8D% of cases, and the average biopsy specimen measured 1.0-40.0 mm. The biopsy diagnoses included both malignant and benign processes. The Temno needle has a lightweight, nonattenuating handle that makes it especially useful for CT-guided procedures

  16. [Intrapulmonary Sewing Needle].

    Science.gov (United States)

    Hisama, Naoya; Tsunemitsu, Nobumasa; Yasumasu, Tetsuo; Yamasaki, Takashi; Uchida, Takahisa

    2016-06-01

    Intrapulmonary aberrant needles are rarely encountered in clinical practice. A 82-year-old woman, though she was asymptomatic, was referred to our department due to an abnormal shadow on a chest X-ray. Chest X-ray and chest computed tomography showed a foreign body suspected to be a sewing needle in the left upper lobe. The needle was successfully removed by video-assisted thoracoscopic surgery.

  17. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Sayani, R.; Rajani, A.

    2012-01-01

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  18. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  19. Robotically steering flexible needles

    NARCIS (Netherlands)

    Abayazid, Momen

    2015-01-01

    Needle insertion into soft tissue is one of the common minimally invasive surgical procedures. Many diagnostic and therapeutic clinical procedures require insertion of a needle to a specific location in soft-tissue, including biopsy or radioactive seed implantation for cancer treatment

  20. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  1. Waste disposal

    International Nuclear Information System (INIS)

    Neerdael, B.; Marivoet, J.; Put, M.; Verstricht, J.; Van Iseghem, P.; Buyens, M.

    1998-01-01

    The primary mission of the Waste Disposal programme at the Belgian Nuclear Research Centre SCK/CEN is to propose, develop, and assess solutions for the safe disposal of radioactive waste. In Belgium, deep geological burial in clay is the primary option for the disposal of High-Level Waste and spent nuclear fuel. The main achievements during 1997 in the following domains are described: performance assessment, characterization of the geosphere, characterization of the waste, migration processes, underground infrastructure

  2. Experiments with needle bearings

    Science.gov (United States)

    Ferretti, Pericle

    1933-01-01

    Experiments and results are presented in testing needle bearings, especially in comparison with roller bearings. Reduction in coefficient of friction is discussed as well as experimental methods and recording devices.

  3. Body Disposal.

    Science.gov (United States)

    Sea, Jonghan; Beauregard, Eric

    2017-02-01

    This study explores the body disposal patterns in a sample of 54 Korean homicides that occurred between 2006 and 2012. Based on information collected by the police during their investigation, factors that could influence body disposal patterns were examined, such as homicide classification, intention, whether an accomplice was present, and offender mental disorder. Bivariate analyses showed that the majority of the victims who were disposed of were acquaintances of the offenders. Moreover, several offenders were more likely to dispose of the dead body "within hours" of killing the victim. Dead bodies were usually recovered in agricultural areas, forest/wooded areas, as well as residential areas. It was also noteworthy that, in 47 cases, the offender had knowledge of the geographic area where the body was dumped. In cases of "expressive" homicide, victims were more likely to be disposed of somewhere far away (e.g., over 40 km) from the crime scene, whereas "instrumental" homicide victims appeared to be disposed of somewhere closer (e.g., within 30 km) to the crime scene. Results are discussed in light of their practical implications for homicide investigations.

  4. Trigger Point Dry Needling.

    Science.gov (United States)

    2017-03-01

    Increasingly, physical therapists in the United States and throughout the world are using dry needling to treat musculoskeletal pain, even though this treatment has been a controversial addition to practice. To better generalize to physical therapy practice the findings about dry needling thus far, the authors of a study published in the March 2017 issue of JOSPT identified the need for a systematic review examining the effectiveness of dry needling performed by physical therapists on people with musculoskeletal pain. Their review offers a meta-analysis of data from several included studies and assesses the evidence for risks of bias. J Orthop Sports Phys Ther 2017;47(3):150. doi:10.2519/jospt.2017.0502.

  5. [Bone biopsy needles: mechanical properties, needle design and specimen quality].

    Science.gov (United States)

    Keulers, A; Cunha-Cruz, V C; Bruners, P; Penzkofer, T; Braunschweig, T; Schmitz-Rode, T; Mahnken, A

    2011-03-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Mosquito inspired medical needles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Hesselberg, Thomas; Drakidis, Alexandros Dimitrios

    2017-01-01

    The stinging proboscis in mosquitos have diameters of only 40-100 μm which is much less than the thinnest medical needles and the mechanics of these natural stinging mechanisms have therefore attracted attention amongst developers of injection devises. The mosquito use a range of different...

  7. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  8. The effect of needle gauge, needle type, and needle orientation on the volume of a drop.

    Science.gov (United States)

    Tripp, Geneva K; Good, Kathryn L; Motta, Monica J; Kass, Philip H; Murphy, Christopher J

    2016-01-01

    The purpose of this study was to determine impact of needle gauge, type, and orientation on average volume of drop dispensed. Five needle gauges (22G, 23G, 25G, 27G, and 30G) were examined. For each gauge, volume of drop delivered was determined for standard sharp beveled tip, blunt tip, and after breaking off of the sharp needle from the hub. Vertical and horizontal orientation of the needle was tested for effect on drop volume for 22-G and 30-G sharp beveled needles. Mean drop volume was affected by needle gauge, needle orientation, and whether the needle had been broken off from its hub. Mean drop volume scaled directly with needle diameter with drop volumes of 25.0 μL (±20.2) and 83.9 μL (±16.5) being found for 30-gauge and 22-gauge needles, respectively. Intermediate gauges (27, 25, 23G) yielded intermediate drop volumes. Blunt needles tended to produce larger drop volumes compared to sharp beveled needles, but these differences did not reach statistical significance. Breaking off of the needle from the hub produced substantially larger drop volumes with little difference being found between needle gauges. Average volumes of 1 drop from a 22-G vertical, 22-G horizontal, 30-G vertical, and 30-G horizontal sharp beveled needle were 20.2, 9.1, 10.1, and 3.3 μL, respectively. These findings have relevance for controlled delivery of topical ophthalmic medications to patients. © 2015 American College of Veterinary Ophthalmologists.

  9. Gamma-ray-induced changes in hypodermal mesocarp tissue plasma membrane of pre- and post-storage muskmelon

    International Nuclear Information System (INIS)

    Lester, G.E.; Whitaker, B.D.

    1996-01-01

    Gamma irradiation (1.0 kGy) of intact, newly harvested, mature muskmelon fruit (Cucumis melo L. var. reticulatus Naud.) appears to have an immediate deleterious effect, but also a long-term beneficial effect, on the integrity and function of the plasma membrane (PM) of hypodermal mesocarp tissue. The initial consequences of gamma irradiation included an increase in the free sterol:phospholipid ratio, resulting at least in part from deglycosylation of steryl glycosides, a decrease in the spinasterol:7-stigmastenol ratio in each of the PM steryl lipids (free sterols, steryl glycosides, and acylated steryl glycosides), and a decrease in H+-ATPase activity. Irradiation did not increase protein loss, suggesting that the decrease in H+-ATPase activity resulted from either direct inactivation of the enzyme or altered PM ordering caused by the steryl lipid modifications. The long-term beneficial effects of irradiation, observed following 10 days of commercial storage, included greater retention of total PM protein, a diminished decline in total PM phospholipids (PL) and in the PL:protein ratio, and maintenance of greater overall H-ATPase activity (activity was the same as in controls on a per mg protein basis, but there was gt 30% more protein in the PM of stored irradiated fruit). These results indicate that 1 kGy gamma irradiation administered prior to storage slowes the progression of two key parameters of senescence, PM protein loss and PL catabolism

  10. Waste disposal

    CERN Multimedia

    2006-01-01

    We should like to remind you that you can have all commonplace, conventional waste (combustible, inert, wood, etc.) disposed of by the TS-FM Group. Requests for the removal of such waste should be made by contacting FM Support on tel. 77777 or by e-mail (Fm.Support@cern.ch). For requests to be acted upon, the following information must be communicated to FM Support: budget code to be debited for the provision and removal of the skip / container. type of skip required (1m3, 4 m3, 7 m3, 15 m3, 20 m3, 30 m3). nature of the waste to be disposed of (bulky objects, cardboard boxes, etc.). building concerned. details of requestor (name, phone number, department, group, etc.). We should also like to inform you that the TS-FM Group can arrange for waste to be removed from work-sites for firms under contract to CERN, provided that the prior authorisation of the CERN Staff Member in charge of the contract is obtained and the relevant disposal/handling charges are paid. You are reminded that the selective sorting o...

  11. Waste disposal

    CERN Multimedia

    2006-01-01

    We should like to remind you that you can have all commonplace, conventional waste (combustible, inert, wood, etc.) disposed of by the TS-FM Group. Requests for the removal of such waste should be made by contacting FM Support on tel. 77777 or by e-mail (Fm.Support@cern.ch). For requests to be acted upon, the following information must be communicated to FM Support: budget code to be debited for the provision and removal of the skip / container; type of skip required (1m3, 4 m3, 7 m3, 15 m3, 20 m3, 30 m3); nature of the waste to be disposed of (bulky objects, cardboard boxes, etc.); building concerned; details of requestor (name, phone number, department, group, etc.). We should also like to inform you that the TS-FM Group can arrange for waste to be removed from work-sites for firms under contract to CERN, provided that the prior authorisation of the CERN Staff Member in charge of the contract is obtained and the relevant disposal/handling charges are paid. You are reminded that the selective sorting...

  12. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  13. Needling the early universe

    International Nuclear Information System (INIS)

    Hawkins, I.; Wright, E.L.

    1988-01-01

    The possibility that the whole microwave background can be produced by a bright population of pregalactic stars at a redshift of a few hundred is explored. The radiation is thermalized by a combination of amorphous silicate, amorphous carbon, graphite, and needle-shaped conducting grains which give rise to the opacity needed at wavelengths greater than 3 cm. The occurrence of distortion in a primordial microwave background spectrum due to its interaction with Population III stars and dust is investigated. The possibility of producing deviations small enough to be consistent with the best available observations, but still detectable by COBE, is considered. 65 references

  14. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Gleasons grade was (3+3. AMACR showed a sensitivity of 93% and a specificity of 97%. It had a positive predictive value of 0.97 and a negative predictive value of 0.94. Basal cell marker, p63 showed absent staining in all the 74 cases. CONCLUSIONS With the advent of prostate specific antigen serum screening and routine use of transrectal ultrasonography, there is a manifold increase in early detection of prostate adenocarcinomas. 18-gauge needle prostate biopsy under transrectal ultrasound guidance is a preferred method for detection of adenocarcinoma because it is associated with low morbidity and it provides information regarding the grade and extent of carcinoma. However, prostate adenocarcinoma has a number of morphological mimics with various architectural patterns. Immunohistochemistry plays a major role in overcoming diagnostic dilemmas encountered due to the presence of morphological and cytological equivocal features in small volume biopsies. To conclude, in morphologically equivocal glandular architectural patterns and cytological features, combination of immunostains highlighting the basal cells and prostate cancer associated marker can help the pathologist to arrive to a diagnosis on the limited amount of tissue available at his disposal. However, applications of both the immunostains have their inherent limitations.

  15. Waste disposal: preliminary studies

    International Nuclear Information System (INIS)

    Carvalho, J.F. de.

    1983-01-01

    The problem of high level radioactive waste disposal is analyzed, suggesting an alternative for the final waste disposal from irradiated fuel elements. A methodology for determining the temperature field around an underground disposal facility is presented. (E.G.) [pt

  16. Ocean Disposal Site Monitoring

    Science.gov (United States)

    EPA is responsible for managing all designated ocean disposal sites. Surveys are conducted to identify appropriate locations for ocean disposal sites and to monitor the impacts of regulated dumping at the disposal sites.

  17. Radioactive waste disposal in Greece

    International Nuclear Information System (INIS)

    Radioactive waste is any material which contains or is contaminated by radionuclides and for which no use is foreseen. According to this definition, a large number of sources, solid, liquid and gaseous, within the Greek territory can be - and, actually, is - declared as waste. The types of such solid sources are presented. It is estimated that these solid sources represent above 90% of all disused sources in Greece. The medical sources of Co-60 and Cs-137 were used in Teletherapy units, while the Ra-226 ones are in the form of needles or tubes used in Brachytherapy. All the industrial sources had been used for measuring moisture, density, thickness, elementary composition, etc. The small sources used by research labs are mainly in the form of discs. The above sources had been imported a long time ago (even 3 decades ago), had been used, and then stored as useless inside the user's premises. Since 1990 all the users of radioactive sources are obliged to return them back to the suppliers when they are no longer in use. In fact, no source is imported unless there is a written declaration of acceptance by its producer. A project concerning the export of all disused sealed sources is in progress. For every source a certificate will be issued, proper container will be purchased and all the necessary documents will be prepared so that it can be transported for final disposal or reuse in a foreign repository facility. Apart from this 'old generated' waste, unsealed radionuclides have always been used in nuclear medicine producing waste. The above radionuclides are used either in vivo (injected or ingested by patients) or in vitro (labeling of blood and other cells). Both uses leave some radioactive waste inside the needles, the tubes, or other material. Since 1991, Greece has a well-established regulatory system for controlling waste from nuclear medicine labs, so that disposing such solid or liquid waste does no harm to the environment. A revision of these regulations has

  18. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  19. [Dissemination of medical information in Europe, the USA and Japan, 1850-1870: focusing on information concerning the hypodermic injection method].

    Science.gov (United States)

    Tsukisawa, Miyoko

    2011-12-01

    Modern medicine was introduced in Japan in the second half of the nineteenth century. In order to investigate this historical process, this paper focuses on the dissemination of information of a new medical technology developed in the mid-nineteenth century; it does so by making comparisons of the access to medical information between Europe, the USA and Japan. The hypodermic injection method was introduced in the clinical field in Europe and the USA as a newly developed therapeutic method during the 1850s and 1870s. This study analyzed information on the medical assessments of this method by clinicians of these periods. The crucial factor in accumulating this information was to develop a worldwide inter-medical communication circle with the aid of the medical journals. Information on the hypodermic injection method was introduced in Japan almost simultaneously with its introduction in Europe and the USA. However, because of the geographical distance and the language barrier, Japanese clinicians lacked access to this worldwide communication circle, and they accepted this new method without adequate medical technology assessments.

  20. The Caenorhabditis elegans GATA factor elt-1 is essential for differentiation and maintenance of hypodermal seam cells and for normal locomotion.

    Science.gov (United States)

    Smith, Judith A; McGarr, Pamela; Gilleard, John S

    2005-12-15

    The Caenorhabditis elegans GATA transcription factor elt-1 has previously been shown to have a central role in the specification of hypodermal (epidermal) cell fates and acts several cell divisions before the birth of hypodermal cells. Here we report that elt-1 also has essential functions during subsequent development. Reporter gene studies show that elt-1 expression is maintained in lateral seam cells throughout development and elt-1 RNA interference experiments support an essential role for elt-1 in the differentiation of lateral seam cells in the embryo. The maintenance of seam-cell fates in all larval stages including L2d and dauer also requires elt-1. The elt-1 RNAi phenotype shows that seam cells are essential for the structural integrity of adult hermaphrodites in the vulval region and for diametric shrinkage during dauer larval formation. By contrast, severe seam-cell loss in the larval stages has little effect on moulting, indicating that the presence of these cells is not essential for this process. The elt-1 reporter gene is also expressed in neurones of the locomotory circuit. Loss of elt-1 function during postembryonic development results in a hypermotility phenotype whereas overexpression of elt-1 leads to a reciprocal phenotype of reduced motility and paralysis. These results suggest that elt-1 is a key regulator of neuronal function in larvae and adult worms.

  1. Missing needle during episiotomy repair

    Directory of Open Access Journals (Sweden)

    Joydeb Roychowdhury

    2008-01-01

    Full Text Available Breakage and missing of the episiotomy needle is not uncommon occurrence at the hands of the junior doctors. Retrieving it from deeper tissue planes following its migration can be a challenging task.

  2. A spatial analysis of the physical and social environmental correlates of discarded needles.

    Science.gov (United States)

    de Montigny, Luc; Moudon, Anne Vernez; Leigh, Barbara C; Kim, Sun-Young

    2011-05-01

    The role that the urban environment plays in influencing drug users' injection and needle disposal decisions is poorly understood. We identified potential attractors and deterrents of needle discarding, and then used a geographic information system (GIS) to quantify these factors for a neighborhood in Montréal, Canada. In multivariate logistic regression, discarded needles were found to have more associations with physical factors than with social factors. Visual exposure and proximity to a single-room occupancy hotel, a pay phone, an adult service or a pawnshop were important physical environmental predictors. These findings are discussed in relation to developing public health and urban design-based harm reduction approaches to needle discarding in public space. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Flexible needle steering for percutaneous therapies.

    Science.gov (United States)

    Glozman, Daniel; Shoham, Moshe

    2006-07-01

    A robotic system is presented for flexible needle steering and control in soft tissue. Flexible needle insertion into a deformable tissue is modeled as a linear beam supported by virtual springs, where the stiffness coefficients of the springs can vary along the needle. Using this simplified model, the forward and inverse kinematics of the needle are solved analytically, thus enabling both path planning and path correction in real time. Given target and obstacle locations, the computer calculates the needle tip trajectory that will avoid the obstacle and hit the target. Using the inverse kinematics algorithm, the corresponding needle base maneuver needed to follow this trajectory is calculated. It is demonstrated that the needle tip path is not unique and can be optimized to minimize lateral pressure of the needle body on the tissue. Needle steering, i.e., the needle base movements that steer the needle tip, is not intuitive. Therefore, the needle insertion procedure is best performed by a robot. The model was verified experimentally on muscle and liver tissues by robotically assisted insertion of a flexible spinal needle. During insertion, the position and shape of the needle were recorded by X-ray. This study demonstrates the ability to curve a flexible needle by its base motion in order to achieve a planned tip trajectory.

  4. Ultrasonic Needles for Bone Biopsy.

    Science.gov (United States)

    Mathieson, Andrew; Wallace, Robert; Cleary, Rebecca; Li Li; Simpson, Hamish; Lucas, Margaret

    2017-02-01

    Bone biopsy is an invasive clinical procedure, where a bone sample is recovered for analysis during the diagnosis of a medical condition. When the architecture of the bone tissue is required to be preserved, a core-needle biopsy is taken. Although this procedure is performed while the patient is under local anaesthesia, the patient can still experience significant discomfort. Additionally, large haematoma can be induced in the soft tissue surrounding the biopsy site due to the large axial and rotational forces, which are applied through the needle to penetrate bone. It is well documented that power ultrasonic surgical devices offer the advantages of low cutting force, high accuracy, and preservation of soft tissues. This paper reports a study of the design, analysis, and test of two novel power ultrasonic needles for bone biopsy that operate using different configurations to penetrate bone. The first utilizes micrometric vibrations generated at the distil tip of a full-wavelength resonant ultrasonic device, while the second utilizes an ultrasonic-sonic approach, where vibrational energy generated by a resonant ultrasonic horn is transferred to a needle via the chaotic motion of a free-mass. It is shown that the dynamic behavior of the devices identified through experimental techniques closely match the behavior calculated through numerical and finite-element analysis methods, demonstrating that they are effective design tools for these devices. Both devices were able to recover trabecular bone from the metaphysis of an ovine femur, and the biopsy samples were found to be comparable to a sample extracted using a conventional biopsy needle. Furthermore, the resonant needle device was also able to extract a cortical bone sample from the central diaphysis, which is the strongest part of the bone, and the biopsy was found to be superior to the sample recovered by a conventional bone biopsy needle.

  5. Elucidation of Arctigenin Pharmacokinetics and Tissue Distribution after Intravenous, Oral, Hypodermic and Sublingual Administration in Rats and Beagle Dogs: Integration of In Vitro and In Vivo Findings.

    Science.gov (United States)

    Li, Jie; Li, Xin; Ren, Yu-Shan; Lv, Yuan-Yuan; Zhang, Jun-Sheng; Xu, Xiao-Li; Wang, Xian-Zhen; Yao, Jing-Chun; Zhang, Gui-Min; Liu, Zhong

    2017-01-01

    Although arctigenin ( AG ) has diverse bioactivities, such as anti-oxidant, anti-inflammatory, anti-cancer, immunoregulatory and neuroprotective activities, its pharmacokinetics have not been systematically evaluated. The purpose of this work was to identify the pharmacokinetic properties of AG via various experiments in vivo and in vitro . In this research, rats and beagle dogs were used to investigate the PK (pharmacokinetics, PK) profiles of AG with different drug-delivery manners, including intravenous (i.v), hypodermic injection (i.h), and sublingual (s.l) administration. The data shows that AG exhibited a strong absorption capacity in both rats and beagle dogs (absorption rate 100%), and a strong elimination ability ( t 1/2 beagle dog (25.9 ± 3.24%) > rat (15.7 ± 9%) > monkey (3.69 ± 0.12%). This systematic investigation of pharmacokinetic profiles of arctigenin (AG) in vivo and in vitro is worthy of further exploration.

  6. Improvement of Depth Profiling into Biotissues Using Micro Electrical Impedance Spectroscopy on a Needle with Selective Passivation

    Directory of Open Access Journals (Sweden)

    Joho Yun

    2016-12-01

    Full Text Available A micro electrical impedance spectroscopy (EIS-on-a-needle for depth profiling (μEoN-DP with a selective passivation layer (SPL on a hypodermic needle was recently fabricated to measure the electrical impedance of biotissues along with the penetration depths. The SPL of the μEoN-DP enabled the sensing interdigitated electrodes (IDEs to contribute predominantly to the measurement by reducing the relative influence of the connection lines on the sensor output. The discrimination capability of the μEoN-DP was verified using phosphate-buffered saline (PBS at various concentration levels. The resistance and capacitance extracted through curve fitting were similar to those theoretically estimated based on the mixing ratio of PBS and deionized water; the maximum discrepancies were 8.02% and 1.85%, respectively. Depth profiling was conducted using four-layered porcine tissue to verify the effectiveness of the discrimination capability of the μEoN-DP. The magnitude and phase between dissimilar porcine tissues (fat and muscle were clearly discriminated at the optimal frequency of 1 MHz. Two kinds of simulations, one with SPL and the other with complete passivation layer (CPL, were performed, and it was verified that the SPL was advantageous over CPL in the discrimination of biotissues in terms of sensor output.

  7. Comparision of Fine Needle Aspiration Cytology and Fine Needle ...

    African Journals Online (AJOL)

    Background: Open biopsy of the breast used to be the main traditional method of diagnosis of breast lumps. Fine Needle Aspiration Cytology (FNAC) was later introduced which depends on suction and thus yields hemorrhagic material for cytological study.This study was undertaken to find out if there is a difference in ...

  8. Histological observation for needle-tissue interactions.

    Science.gov (United States)

    Nakagawa, Yoshiyuki; Koseki, Yoshihiko

    2013-01-01

    We histologically investigated tissue fractures and deformations caused by ex vivo needle insertions. The tissue was formalin-fixed while the needle remained in the tissue. Following removal of the needle, the tissue was microtomed, stained, and observed microscopically. This method enabled observations of cellular and tissular conditions where deformations caused by needle insertions were approximately preserved. For this study, our novel method presents preliminary findings related with tissue fractures and the orientation of needle blade relative to muscle fibers. When the needle blade was perpendicular to the muscle fiber, transfiber fractures and relatively large longitudinal deformations occurred. When the needle blade was parallel to the muscle fiber, interfiber fractures and relatively small longitudinal deformations occurred. This made a significant difference in the resistance force of the needle insertions.

  9. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various ...

  10. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  11. Dry needling — peripheral and central considerations

    OpenAIRE

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects...

  12. KINEMATICS FRICTION PAIR FOR EXAMPLE NEEDLE BEARINGS

    OpenAIRE

    Jerzy NACHIMOWICZ; Robert KORBUT

    2014-01-01

    The present study concerns certain phenomena that take place in the needle roller bearing. The friction that generates the anti-torque of a friction pair is the major factor that influences the needle bearing’s wear. In the needle bearing there occur two predominant types of friction: the rolling friction and the sliding friction, and both are subject to examination. The study presents recordings and analysis of the movements of all needle bearing’s rolling elements. The examination was carri...

  13. Autosizing Control Panel for Needle Bearing

    OpenAIRE

    Prof.A.R.Wadhekar,; Ms Jyoti R. Rajput

    2016-01-01

    A needle roller bearing is a bearing which uses small cylindrical rollers. Bearings are used to reduce friction of any rotating surface. Needle bearings have a large surface in contact with the bearing outer surfaces as compared to ball bearings. There is less added clearance(Diameter of the shaft and the diameter of the bearing are different) so they are much compact. The structure consists of a needle cage which contains the needle rollersthemselves and an outer race (The housin...

  14. The borehole disposal of spent sources (BOSS)

    International Nuclear Information System (INIS)

    Heard, R.G.

    2002-01-01

    During the International Atomic Energy Agency (IAEA) Regional Training Course on 'The Management of Low-Level Radioactive Waste from Hospitals and Other Nuclear Applications' hosted by the Atomic Energy Corporation of SA Ltd. (AEC), now NECSA, during July/August 1995, the African delegates reviewed their national radioactive waste programmes. Among the issues raised, which are common to most African countries, were the lack of adequate storage facilities, lack of disposal solutions and a lack of equipment to implement widely used disposal concepts to dispose of their spent sources. As a result of this meeting, a Technical Co-operation (TC) project was launched to look at the technical feasibility and economic viability of such a concept. Phase I and II of the project have been completed and the results can be seen in three reports produced by NECSA. The Safety Assessment methodology used in the evaluation of the concept was that developed during the ISAM programme and detailed in Van Blerk's PhD thesis. This methodology is specifically developed for shallow land repositories, but was used in this case as the borehole need not be more than 100m deep and could fit into the definition of a shallow land disposal system. The studies found that the BOSS concept would be suitable for implementation in African countries as the borehole has a large capacity for sources and it is possible that an entire country's disused sources can be placed in a single borehole. The costs are a lot lower than for a shallow land trench, and the concept was evaluated using radium (226) sources as the most limiting inventory. The conclusion of the initial safety assessment was that the BOSS concept is robust, and provides a viable alternative for the disposal of radium needles. The concept is expected to provide good assurance of safety at real sites. The extension of the safety assessment to other types of spent sources is expected to be relatively straightforward. Disposal of radium needles

  15. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  16. Rhizosphaera Needle Disease of Fir

    Science.gov (United States)

    Mike Albers; Jana Albers; Jane Cummings-Carlson; Linda Haugen; Nancy Wenner

    1996-01-01

    Rhizosphaera pini is a common plant pathogen in the Lake States, Northeastern States and Canada. A closely related pathogen, Rhizosphaera kalkhoffii, causes a common needle blight on spruce and other conifers. R. pini is often considered to be a weak pathogen, occurring on stressed foliage or foliage killed by other causes. However, it has been observed causing...

  17. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  18. A study of needle stick injuries among non-consultant hospital doctors in Ireland.

    LENUS (Irish Health Repository)

    O'Connor, M B

    2012-02-01

    INTRODUCTION: NCHDs are exposed to a great number of blood-borne infections. Needle stick injuries are possibly the main route of acquiring such infections from a non-consultant hospital doctors (NCHDs) perspective. This study examines NCHDs experiences surrounding needle stick injuries. METHODS: A cross-sectional self-administered anonymous questionnaire survey was conducted on 185 NCHDs working in a clinical setting among seven teaching hospitals in Ireland. Implied consent was obtained. The data was analysed using Excel spreadsheets. Ethical approval was received. RESULTS: A response rate of 85.4% (158\\/185) was achieved. Findings of the study are shown in the manuscript table. CONCLUSIONS: A needle stick injury (NI) history is greater among surgical NCHDs than medical NCHDs. The level of disposable glove usage is worryingly poor. Training in sharps handling and dealing with a NI needs to be addressed. HIV is the blood-borne infection most fear of being contracting as a consequence of a NI.

  19. 29 gauge needles improve patient satisfaction over 27 gauge needles for daily glatiramer acetate injections

    Directory of Open Access Journals (Sweden)

    Stephen Glenski

    2009-12-01

    Full Text Available Stephen Glenski, Jill ConnerMedical Affairs – Teva Neuroscience, Kansas City, MO, USAAbstract: Using three surveys, a comparative assessment of needle performance and patient preference for 27-gauge (G and 29G needles for glatiramer acetate administration for multiple sclerosis therapy was performed. Eligible patients participated in a specialty pharmacy program and administered glatiramer acetate for ≥1 month. In Survey 1 on the 27G needle, 545 (82.70% patients reported no needle problems, 106 (16.09% cited one type (dull, bent, or broken, five (0.76% cited two types, and three (0.46% cited all three types. In Survey 2 on the 29G needle, 553 (98.05% indicated no problems, two (0.35% cited dull needles, and nine (1.60% cited bent needles. On the 29G needles versus 27G needles pain comparison, 219 (38.83% reported the 29G needle was a little better, and 155 (27.48% reported it was a lot better than the 27G. For injection-site experiences, 515 patients (91.31% reported no, very slight, or mild reactions with the 29G needle. In Survey 3, over 76% of patients preferred the 29G to the 27G needle and significantly fewer patients reported one or more problems with the 29G needle compared to patients reporting problems with the 27G needle (P < 0.00001. In conclusion, significantly fewer patients reported problems after 30 days of use of the 29G than the 27G needle. Fewer injectionsite experiences occurred with the 29G needle and the 29G needle was preferred overall.Keywords: 29 gauge needle, subcutaneous injection, glatiramer acetate

  20. Radioactive waste disposal policy

    International Nuclear Information System (INIS)

    Neilson, H.R.

    1982-01-01

    The responsibilities of the Minister of Agriculture, Fisheries and Food and Ministry policy on radioactive waste disposal are described. The disposal of solid radioactive waste at sea is subject to detailed safeguards developed within two international agreements to which the United Kingdom is a contracting party. The agreements are discussed together with a research and monitoring programme to provide scientific data for informed decisions on waste disposal authorisations and dumping licences. (U.K.)

  1. [From manual workshop to international standard maker: exploration on production standard of acupuncture needle by Chengjiang acupuncture school].

    Science.gov (United States)

    Cheng, Jie; Cao, Yang; Xia, Youbing

    2015-02-01

    ABSTRACT The exploration course on production standard of acupuncture needle by Chengjiang acupuncture school is reviewed in this paper. After new China was established, acupuncture needle standard was unified by Mr. CHENG Dan-an, which guided Suzhou Hua Erfang (predecessor of Suzhou Medical Supplies Factory) to make the quality standards and testing methods of acupuncture needle and improved the production process to make the modern acupuncture needle. Based on this, Suzhou Medical Supplies Factory followed the time development pace, ac tively introduced new technology, carried out technological innovation, and constantly improved the level of production technology, as a result, it gradually developed into one of the world's largest acupuncture needle production suppliers. Meanwhile, after establishing China's first national standard on acupuncture needle (GB 2024-1980), the Suzhou Medical Supplies Factory took the lead to draft "ISO) 17218:2014 the disposable use asepsis acupuncture needle", which was officially published as an international standard. The Suzhou Medical Supplies Factory developed from a manual workshop to an international standard maker.

  2. Proteomic analysis of differentially expressed protein in hemocytes of wild giant freshwater prawn Macrobrachium rosenbergii infected with infectious hypodermal and hematopoietic necrosis virus (IHHNV).

    Science.gov (United States)

    Alinejad, T; Bin, Kwong Q; Vejayan, J; Othman, R Y; Bhassu, S

    2015-09-01

    Epizootic diseases cause huge mortality and economical loses at post larvae stages in freshwater prawn aquaculture industry. These prawns seem less susceptible to viral diseases except for infectious hypodermal and hematopoietic necrosis virus (IHHNV). During viral infection in prawns, hemocytes are the primary organ that shows immunological response within the early stages of infection. We applied proteomic approaches to understand differential expression of the proteins in hemocytes during the viral disease outbreak. To aid the goal, we collected Macrobrachium rosenbergii broodstocks from the local grow out hatchery which reported the first incidence of IHHNV viral outbreak during larvae stage. Primarily, application of the OIE primer targeting 389 bp fragments of IHHNV virus was used in identification of the infected and non-infected samples of the prawn breeding line. Analysis of two-dimensional gel electrophoresis showed specific down-regulation of Arginine kinase and Sarcoplasmic calcium-binding protein and up/down-regulation of Prophenoloxidase1 and hemocyanin isoforms. These proteins were validated using semi quantitative RT-PCR and gene transcripts at mRNA level. These identified proteins can be used as biomarkers, providing a powerful approach to better understanding of the immunity pathway of viral disease with applications in analytic and observational epidemiology diagnosis. Proteomic profiling allows deep insight into the pathogenesis of IHHNV molecular regulation and mechanism of hemocyte in freshwater prawns.

  3. Susceptibility to an inoculum of infectious hypodermal and haematopoietic necrosis virus (IHHNV) in three batches of whiteleg shrimp Litopenaeus vannamei (Boone, 1931)

    Science.gov (United States)

    Escobedo-Bonilla, César Marcial; Rangel, José Luis Ibarra

    2014-01-01

    Abstract The present study evaluated the susceptibility of three different batches of whiteleg shrimp Litopenaeus vannamei from Mexico to an inoculum of infectious hypodermal and haematopoietic necrosis virus (IHHNV). Each of the three shrimp batches came from a different hatchery. Because of their origin, it was possible that the genetic makeup of these batches was different among each other. The three batches tested showed differences in IHHNV susceptibility. Here, susceptibility is defined as the capacity of the host to become infected, and it can be measured by the infectivity titer. Susceptibility to IHHNV was observed in decreasing order in shrimp from batch 1 (hatchery from El Rosario, Sinaloa), batch 3 (hatchery from Nayarit) and batch 2 (hatchery from El Walamo, Sinaloa), respectively. The largest susceptibility difference between batches was 5012 times, and that between early and late juveniles from the same batch was 25 times. These results indicate that within a species, susceptibility to a pathogen such as IHHNV can have large differences. Susceptibility to pathogens is an important trait to consider before performing studies on pathogenesis. It may influence virological parameters such as speed of replication, pathogenicity and virus titer. In order to evaluate the potential use of IHHNV as a natural control agent against white spot syndrome virus (WSSV), it is necessary to know host susceptibility and the kinetics of IHHNV infection. These features can help to determine the conditions in which IHHNV could be used as antagonist in a WSSV infection. PMID:25561847

  4. Susceptibility to an inoculum of infectious hypodermal and haematopoietic necrosis virus (IHHNV) in three batches of whiteleg shrimp Litopenaeusvannamei (Boone, 1931).

    Science.gov (United States)

    Escobedo-Bonilla, César Marcial; Rangel, José Luis Ibarra

    2014-01-01

    The present study evaluated the susceptibility of three different batches of whiteleg shrimp Litopenaeusvannamei from Mexico to an inoculum of infectious hypodermal and haematopoietic necrosis virus (IHHNV). Each of the three shrimp batches came from a different hatchery. Because of their origin, it was possible that the genetic makeup of these batches was different among each other. The three batches tested showed differences in IHHNV susceptibility. Here, susceptibility is defined as the capacity of the host to become infected, and it can be measured by the infectivity titer. Susceptibility to IHHNV was observed in decreasing order in shrimp from batch 1 (hatchery from El Rosario, Sinaloa), batch 3 (hatchery from Nayarit) and batch 2 (hatchery from El Walamo, Sinaloa), respectively. The largest susceptibility difference between batches was 5012 times, and that between early and late juveniles from the same batch was 25 times. These results indicate that within a species, susceptibility to a pathogen such as IHHNV can have large differences. Susceptibility to pathogens is an important trait to consider before performing studies on pathogenesis. It may influence virological parameters such as speed of replication, pathogenicity and virus titer. In order to evaluate the potential use of IHHNV as a natural control agent against white spot syndrome virus (WSSV), it is necessary to know host susceptibility and the kinetics of IHHNV infection. These features can help to determine the conditions in which IHHNV could be used as antagonist in a WSSV infection.

  5. Dry needling — peripheral and central considerations

    Science.gov (United States)

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture. PMID:23115475

  6. Dry needling - peripheral and central considerations.

    Science.gov (United States)

    Dommerholt, Jan

    2011-11-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture.

  7. hydrolysis rates of domestic wastewater sludge using biochemical

    African Journals Online (AJOL)

    eobe

    biodegradable organic matter into more readily soluble biodegradable matter which can then serve as ... fh is the biodegradable fraction of substrate, kh is the hydrolysis rate constant (day-1), t is the time (day) and e is the ... septum cap using Plastipak® 2 mL disposable plastic hypodermic syringes and 21-guage needles ( ...

  8. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  9. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    are found in the literature of needled/felted carbon-carbon (C/C) composites for high temperature applications such as ablative aerospace heat shields...carbon fibers themselves. Reductions in tensile strength of up to 25% for stitched carbon/ epoxy composites have been reported, as have drops in elastic...laminate plane. Previous work with needled glass/ epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  10. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  11. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  12. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  13. How needless are Buffon's needles?

    International Nuclear Information System (INIS)

    Babović, Miloš; Babović, Vukota

    2013-01-01

    The study of statistical physics requires introductory preparation regarding probability theory. Understanding its fundamental concepts (randomness, distributions, fluctuations), and some experience in application of the basic concepts of statistics can be obtained in several ways. We found that the basic training in probability and statistics needed for physics and engineering study can be achieved by focusing on Buffon's needle problem. We believe this approach could help university specialists make study more efficient when probability and statistics play an important role. Buffon's experiment, with its convincing simplicity and flexibility, as well as its attractiveness, is in our opinion a useful tool in physics education at university level. (paper)

  14. Disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Blomeke, J.O.

    1979-01-01

    Radioactive waste management and disposal requirements options available are discussed. The possibility of beneficial utilization of radioactive wastes is covered. Methods of interim storage of transuranium wastes are listed. Methods of shipment of low-level and high-level radioactive wastes are presented. Various methods of radioactive waste disposal are discussed

  15. Disposable Diapers Are OK.

    Science.gov (United States)

    Poore, Patricia

    1992-01-01

    A personal account of measuring the pros and cons of disposable diaper usage leads the author to differentiate between a garbage problem and environmental problem. Concludes the disposable diaper issue is a political and economic issue with a local environmental impact and well within our abilities to manage. (MCO)

  16. Geographical and climatic limits of needle types of one- and two-needled pinyon pines.

    Science.gov (United States)

    Cole, Kenneth L; Fisher, Jessica; Arundel, Samantha T; Cannella, John; Swift, Sandra

    2008-02-01

    AIM: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. LOCATION: Western North America. METHODS: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. RESULTS: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  17. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  18. Intervention study of needle stick injury in Iran

    International Nuclear Information System (INIS)

    Mobasherizadeh, Sina; Abne-Shahidi, Sayed A.; Mohammadi, Nazafarin A.; Abazari, Fereshteh

    2005-01-01

    Injury resulting from contaminated sharp devices among health care workers (HCWs) is one of the most important concerns in medical centers. This can lead to dangerous infections such as human immunodeficiency virus, hepatitis B virus and hepatitis C virus among such people. The documentation of needle stick injuries started in Sadi Hospital, Isfahan, Iran in 2003, and our objective was to study cases of injuries by sharp devices before and after the implementation of intervention methods. In an intervention survey of the type of before and after study, we studied injuries by needle and other sharp devices among 87 HCWs in Sadi Hospital, a private hospital in Isfahan, Iran, during the years 2003-2004. The groups under study were workers and paramedical staff; and the wards under study included surgery, internal, lab, x-ray and laundry. We entered and evaluated the data in SPSS software. In the first phase of the study in 2003, 55.2% of those injured had been injured by sharp devices. After intervention in 2004, this percentage was reduced to 19.5% (p < 0.05). At the beginning of the study, 26.4% of the injured had been injured by sharp devices more than twice, and at the end of the study this number was reduced to 2.3% (p < 0.05). Also, injuries resulting from recapping were 45.8% at the beginning of the study, which was reduced to 5.9% at the end (p < 0.05). With regard to this study and other studies carried out in other countries, a large number of injuries by contaminated sharp devices can be prevented by implementing suitable educational programs regarding disposal of sharp devices, and by using safe needle devices. (author)

  19. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  20. Sugar export limits size of conifer needles

    DEFF Research Database (Denmark)

    Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas

    2017-01-01

    produced near the tip of long needles cannot be exported efficiently, because the pressure required to drive vascular flow would exceed the greatest available pressure (the osmotic pressure). This basic constraint leads to the formation of an inactive region of stagnant fluid near the needle tip, which...

  1. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Directory of Open Access Journals (Sweden)

    Bertrand Y. K. Loyeung

    2013-01-01

    Full Text Available Introduction. In traditional Chinese acupuncture, needle sensation (deqi is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site.

  2. RCN1/OsABCG5, an ATP-binding cassette (ABC) transporter, is required for hypodermal suberization of roots in rice (Oryza sativa).

    Science.gov (United States)

    Shiono, Katsuhiro; Ando, Miho; Nishiuchi, Shunsaku; Takahashi, Hirokazu; Watanabe, Kohtaro; Nakamura, Motoaki; Matsuo, Yuichi; Yasuno, Naoko; Yamanouchi, Utako; Fujimoto, Masaru; Takanashi, Hideki; Ranathunge, Kosala; Franke, Rochus B; Shitan, Nobukazu; Nishizawa, Naoko K; Takamure, Itsuro; Yano, Masahiro; Tsutsumi, Nobuhiro; Schreiber, Lukas; Yazaki, Kazufumi; Nakazono, Mikio; Kato, Kiyoaki

    2014-10-01

    Suberin is a complex polymer composed of aliphatic and phenolic compounds. It is a constituent of apoplastic plant interfaces. In many plant species, including rice (Oryza sativa), the hypodermis in the outer part of roots forms a suberized cell wall (the Casparian strip and/or suberin lamellae), which inhibits the flow of water and ions and protects against pathogens. To date, there is no genetic evidence that suberin forms an apoplastic transport barrier in the hypodermis. We discovered that a rice reduced culm number1 (rcn1) mutant could not develop roots longer than 100 mm in waterlogged soil. The mutated gene encoded an ATP-binding cassette (ABC) transporter named RCN1/OsABCG5. RCN1/OsABCG5 gene expression in the wild type was increased in most hypodermal and some endodermal roots cells under stagnant deoxygenated conditions. A GFP-RCN1/OsABCG5 fusion protein localized at the plasma membrane of the wild type. Under stagnant deoxygenated conditions, well suberized hypodermis developed in wild types but not in rcn1 mutants. Under stagnant deoxygenated conditions, apoplastic tracers (periodic acid and berberine) were blocked at the hypodermis in the wild type but not in rcn1, indicating that the apoplastic barrier in the mutant was impaired. The amount of the major aliphatic suberin monomers originating from C(28) and C(30) fatty acids or ω-OH fatty acids was much lower in rcn1 than in the wild type. These findings suggest that RCN1/OsABCG5 has a role in the suberization of the hypodermis of rice roots, which contributes to formation of the apoplastic barrier. © 2014 The Authors The Plant Journal © 2014 John Wiley & Sons Ltd.

  3. Elucidation of Arctigenin Pharmacokinetics and Tissue Distribution after Intravenous, Oral, Hypodermic and Sublingual Administration in Rats and Beagle Dogs: Integration of In Vitro and In Vivo Findings

    Directory of Open Access Journals (Sweden)

    Jie Li

    2017-06-01

    Full Text Available Although arctigenin (AG has diverse bioactivities, such as anti-oxidant, anti-inflammatory, anti-cancer, immunoregulatory and neuroprotective activities, its pharmacokinetics have not been systematically evaluated. The purpose of this work was to identify the pharmacokinetic properties of AG via various experiments in vivo and in vitro. In this research, rats and beagle dogs were used to investigate the PK (pharmacokinetics, PK profiles of AG with different drug-delivery manners, including intravenous (i.v, hypodermic injection (i.h, and sublingual (s.l administration. The data shows that AG exhibited a strong absorption capacity in both rats and beagle dogs (absorption rate < 1 h, a high absorption degree (absolute bioavailability > 100%, and a strong elimination ability (t1/2 < 2 h. The tissue distributions of AG at different time points after i.h showed that the distribution of AG in rat tissues is rapid (2.5 h to reach the peak and wide (detectable in almost all tissues and organs. The AG concentration in the intestine was the highest, followed by that in the heart, liver, pancreas, and kidney. In vitro, AG were incubated with human, monkey, beagle dog and rat liver microsomes. The concentrations of AG were detected by UPLC-MS/MS at different time points (from 0 min to 90 min. The percentages of AG remaining in four species’ liver microsomes were human (62 ± 6.36% > beagle dog (25.9 ± 3.24% > rat (15.7 ± 9% > monkey (3.69 ± 0.12%. This systematic investigation of pharmacokinetic profiles of arctigenin (AG in vivo and in vitro is worthy of further exploration.

  4. KINEMATICS FRICTION PAIR FOR EXAMPLE NEEDLE BEARINGS

    Directory of Open Access Journals (Sweden)

    Jerzy NACHIMOWICZ

    2014-06-01

    Full Text Available The present study concerns certain phenomena that take place in the needle roller bearing. The friction that generates the anti-torque of a friction pair is the major factor that influences the needle bearing’s wear. In the needle bearing there occur two predominant types of friction: the rolling friction and the sliding friction, and both are subject to examination. The study presents recordings and analysis of the movements of all needle bearing’s rolling elements. The examination was carried out on a special examination stand that precisely emulates the real conditions of the needle bearing’s work. Carefully prepared examination methods enable recording and analyzing frictions in the bearing, estimating a sphere within which the load is shifted, and calculating the coefficient of friction.

  5. Integrated Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the center of the 586-square-mile Hanford Site is the Integrated Disposal Facility, also known as the IDF.This facility is a landfill similar in concept...

  6. Nuclear fuel waste disposal

    International Nuclear Information System (INIS)

    Merrett, G.J.; Gillespie, P.A.

    1983-07-01

    This report discusses events and processes that could adversely affect the long-term stability of a nuclear fuel waste disposal vault or the regions of the geosphere and the biosphere to which radionuclides might migrate from such a vault

  7. Disposable Visual Sensor

    National Research Council Canada - National Science Library

    Amidon, Charles P

    2005-01-01

    A disposable visual sensor includes a body defining an enclosed chamber, a power source mounted in the camber, an on-off switch mounted on the body and accessible from outside the body, a processor...

  8. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Shallow land disposal technology

    Energy Technology Data Exchange (ETDEWEB)

    Pillette-Cousin, L. [Nuclear Environment Technology Insitute, Taejon (Korea, Republic of Korea )

    1997-12-31

    This paper covers the radioactive waste management policy and regulatory framework, the characteristics of low and intermediate level radioactive waste, the characteristics of waste package, the waste acceptance criteria, the waste acceptance and related activities, the design of the disposal system, the organization of waste transportation, the operation feature, the safety assessment of the Centre de L`Aube, the post closure measures, the closure of the Centre de la Mache disposal facility, the licensing issues. 3 tabs., 7 figs.

  10. Shallow land disposal technology

    International Nuclear Information System (INIS)

    Pillette-Cousin, L.

    1997-01-01

    This paper covers the radioactive waste management policy and regulatory framework, the characteristics of low and intermediate level radioactive waste, the characteristics of waste package, the waste acceptance criteria, the waste acceptance and related activities, the design of the disposal system, the organization of waste transportation, the operation feature, the safety assessment of the Centre de L'Aube, the post closure measures, the closure of the Centre de la Mache disposal facility, the licensing issues. 3 tabs., 7 figs

  11. The Biological Safety of Stainless Steel Needles Used in Warm-Needling

    Directory of Open Access Journals (Sweden)

    Sabina Lim

    2010-01-01

    Full Text Available Warm-needling (also called thermo-acupuncture is a combination of acupuncture and moxibustion. Due to the intense heat involved, there have been concerns over the biological safety of the acuneedles used in the treatment. This paper reports two phases of a safety test. For a preliminary test, we compared the temperature change patterns of stainless steel (SS304 needles and traditional gold alloy needles, which have been increasingly replaced by the former. To verify the effects of the presence of coating materials, the main test involved three different kinds of SS304: silicone-coated, salicylic acid-coated and non-coated needles. Each group of needles was tested for pH level, heavy metals and UV absorbance spectrum along with biological tests on the cytotoxicity and hemolysis of the needle. All the tests on the extractants from the needles were negative. In the biological tests, each test result showed a significant difference from the positive control samples, while no significant difference was observed compared with the negative control samples. In the hemolysis tests, all samples satisfied the Korean Government Standards. All the results suggest that SS304 needles are biologically safe to be used in warm-needling, though they can be improved to perform as well as the gold alloy needles in terms of temperature fluctuations.

  12. Complications of transradial coronary angiography: a comparative study between using trocar needle and using bare needle

    International Nuclear Information System (INIS)

    Huang Chunyan; Wang Zhongjie; Chen Liyuan

    2010-01-01

    Objective: To analyze the advantages and disadvantages of trocar needle puncturing and bare needle puncturing in performing transradial coronary angiography through comparing the surgical successful rate and the occurrence of complications between two techniques. Methods: A total of 450 patients, who were scheduled to receive transradial coronary angiography, were enrolled in this study. The patients were randomly and equally divided into trocar needle group (n=225) and bare needle group (n=225). Transradial coronary angiography was performed in all patients, the technical success and the puncture-related complications were observed. The differences between two groups were compared and the results were statistically analyzed. Results: The successful rate of placing sheath pipe in trocar needle group and bare needle group was 98.22% (221/225) and 90.22% (203/225) respectively, the difference between two groups was statistically significant (P < 0.01). The mean time spent in puncturing in trocar needle group and bare needle group was (3.98 ± 0.54) min. and (6.13 ± 0.61) min. respectively (P < 0.01). In bare needle group the complications included radial artery spasm (4.89%, n=11), subcutaneous ecchymosis (6.67%, n=15) and local hematoma (3.56%, n=8), while in trocar group the complications included radial artery spasm (1.33%, n=3), subcutaneous ecchymosis (2.67%, n=6) and local hematoma (0.44%, n=1). Conclusion: In performing percutaneous coronary arteriography via radial arterial access the use of trocar needle is superior to the use of bare needle. Using trocar needle can reduce the operative time,increase the technical successful rate and lower the occurrence of complications. Therefore, using trocar needle to perform puncturing should be the technique of first choice. (authors)

  13. [Comparison of analgesic effects between subcutaneous penetration needling and straight needling of otopoints in the treatment of scapulohumeral periarthritis].

    Science.gov (United States)

    Jia, Chun-Sheng; Li, Xiao-Feng; Ma, Xiao-Shun; Shi, Jing; Liu, Er-Jun

    2008-10-01

    To confirm the better analgesic effect of subcutaneous penetration needling of otopoints for treatment of scapulohumeral periarthritis (SHPA) patients. Sixty-six SHPA patients were randomized into penetration-needling group (n = 33) and straight needling group (n = 33) by using pairing principle according to the sex and state of disease. Penetration needling was adopted for patients of penetration-needling group, while straight needling was used for those of straight needling group. Simplified McGill Scale was used to evaluate the patients' pain reactions. The pain integral scores were analyzed by using sequential test and pairing t test. Sequential test showed that the analgesic effect of penetration needling was significantly superior to that of straight needling 30 min after the treatment (P straight needling (P straight needling in the treatment of scapulohumeral periarthritis.

  14. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  15. [Design thinking and clinical basic operation rules of the needling instrument for Shu-needle therapy].

    Science.gov (United States)

    Bao, Shou-qian

    2009-03-01

    Shu-needle therapy is a transcutaneous, close and micro-traumatic treatment technique founded on the basis of the theoretical system and the treatment thought of TCM acupuncture eye surgery. This therapy uses the needling instrument for Shu-needle therapy of original creation to relieve pressure, relieve tension, relieve spasm, relieve rigid, etc. for chronic pain, and achieves unique clinical therapeutic effects, and it originally creates the diagnostic and therapeutic system of special acupoint selection for human chronic pain and difficult diseases of the vegetable nerves and important treatment rules, in combination with modern medicine. Shu-needle therapy mixes TCM surgery with the cream of other special acupuncture therapies, and it is a new development and supplement of special needling therapies such as small needle knife, etc. and traditional acupuncture treatment.

  16. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  17. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  18. Intracranial sewing needles in an adult patient.

    Science.gov (United States)

    Kazanci, Atilla; Ozdemir, Halil Ibrahim; Kazanci, Burak; Kazanci, Dilek Ozturk; Er, Uygur

    2012-01-01

    A 37-year-old patient is reported with intracranial sewing needles, which were located in the right frontal lobe. Both clinical and radiological findings suggested that these needles must have been introduced in infancy before the closure of anterior fontanelle during an unsuccessful homicide. Usually intracranial foreign objects are placed due to penetrating trauma or surgical procedures. Child abuse has been known for centuries. Many types of physical traumas have been reported, especially in Western countries. In Iran, insertion of sewing needles into the brain aiming to kill the infant have been seen in a lot of cases. This situation takes part in a lot of Persian stories. We reported a 37-year-old man who had 2 intracranial sewing needles with unknown etiology.

  19. Inverse Kinematics of Concentric Tube Steerable Needles.

    Science.gov (United States)

    Sears, Patrick; Dupont, Pierre E

    2007-01-01

    Prior papers have introduced steerable needles composed of precurved concentric tubes. The curvature and extent of these needles can be controlled by the relative rotation and translation of the individual tubes. Under certain assumptions on the geometry and design of these needles, the forward kinematics problem can be solved in closed form by means of algebraic equations. The inverse kinematics problem, however, is not as straightforward owing to the nonlinear map between relative tube displacements and needle tip configuration as well as to the multiplicity of solutions as the number of tubes increases. This paper presents a general approach to solving the inverse kinematics problem using a pseudoinverse solution together with gradients of nullspace potential functions to enforce geometric and mechanical constraints.

  20. Root canal obturation of primary teeth: Disposable injection technique

    Directory of Open Access Journals (Sweden)

    S K Bhandari

    2012-01-01

    Full Text Available The aim of the study was to outline a simple, cost-effective technique for obturation of primary tooth root canals. A total of 75 primary teeth were treated in 52 subjects by the technique discussed, i.e. injecting plastic flowable material into the root canals after desired preparation, using disposable needle and syringe. All the patients were followed up for 3 years and 6 months, with no clinical or radiologic evidence of pathology or need for untimely extraction. In conclusion, the technique described is simple, economical, can be used with almost all filling materials used for the purpose, and is easy to master with minimal chances of failure.

  1. Disposal of hazardous wastes

    International Nuclear Information System (INIS)

    Barnhart, B.J.

    1978-01-01

    The Fifth Life Sciences Symposium entitled Hazardous Solid Wastes and Their Disposal on October 12 through 14, 1977 was summarized. The topic was the passage of the National Resources Conservation and Recovery Act of 1976 will force some type of action on all hazardous solid wastes. Some major points covered were: the formulation of a definition of a hazardous solid waste, assessment of long-term risk, list of specific materials or general criteria to specify the wastes of concern, Bioethics, sources of hazardous waste, industrial and agricultural wastes, coal wastes, radioactive wastes, and disposal of wastes

  2. Plumbing and Sewage Disposal.

    Science.gov (United States)

    Sutliff, Ronald D.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the principles of plumbing and sewage disposal used by Marine Hygiene Equipment Operators to perform their mission. The course contains three study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the…

  3. Waste disposal package

    Science.gov (United States)

    Smith, M.J.

    1985-06-19

    This is a claim for a waste disposal package including an inner or primary canister for containing hazardous and/or radioactive wastes. The primary canister is encapsulated by an outer or secondary barrier formed of a porous ceramic material to control ingress of water to the canister and the release rate of wastes upon breach on the canister. 4 figs.

  4. Radwaste treatment and disposal

    International Nuclear Information System (INIS)

    Ehn, L.; Breza, M.; Pekar, A.

    2000-01-01

    In this lecture is given the basic information, that is concerning on the RAW treatment and long term disposal of the treated RAW in repository at Mochovce. Then here is given the basic technical and technological information, that is concerning bituminization, plant, the vitrification unit, center for the RAW-treatment (BSC) and repository at Mochovce. (authors)

  5. Needle stick injuries among dental students: risk factors and recommendations for prevention

    Science.gov (United States)

    Gaballah, Kamis; Warbuton, Dorothy; Sihmbly, Kamal; Renton, Tara

    2012-01-01

    Aim To evaluate the risk factors of needle stick injuries (NSIs) sustained by undergraduate dental students and nurse students at the King's College London (KCL) Dental Institute. Materials and methods A retrospective study evaluated the incident reports relating to NSIs reported over a period of 2 years. Factors including the dental department, study year, and when the injury took place during administration of local anaesthesia (LA) and recapping conventional syringe or clearing work surface or during disposal. Results This report showed that students are at the highest risk of NSIs at the fourth year of their 5-year BDS course. About one-third of injuries were reported among this group of students followed by year 5 students (25%). Oral surgery clinics were the major source of incident reporting when compared with other specialised dental clinics within the institute. The left hands of the students were the most frequently affected by such injuries and then the right hands of student dental nurses. The attempt of needle recapping of conventional syringes was the least reported mechanism of injuries and constituted only 15% of the total injuries and mainly occurred in third year students. The most frequent injuries among student nurses were during disposal of the needle. Conclusion Less NSIs occur when using safety syringes. A non-recapping policy with immediate disposal of either the conventional or safety syringe systems after injection would prevent all clearance-related NSIs sustained by nurses. To avoid NSIs, education plays a vital role particularly with effective implementation of the change to safety syringes with appropriate training. PMID:22741025

  6. Needle stick injuries among dental students: risk factors and recommendations for prevention

    Directory of Open Access Journals (Sweden)

    Kamis Gaballah

    2012-06-01

    Full Text Available Aim: To evaluate the risk factors of needle stick injuries (NSIs sustained by undergraduate dental students and nurse students at the King's College London (KCL Dental Institute. Materials and methods: A retrospective study evaluated the incident reports relating to NSIs reported over a period of 2 years. Factors including the dental department, study year, and when the injury took place during administration of local anaesthesia (LA and recapping conventional syringe or clearing work surface or during disposal. Results: This report showed that students are at the highest risk of NSIs at the fourth year of their 5-year BDS course. About one-third of injuries were reported among this group of students followed by year 5 students (25%. Oral surgery clinics were the major source of incident reporting when compared with other specialised dental clinics within the institute. The left hands of the students were the most frequently affected by such injuries and then the right hands of student dental nurses. The attempt of needle recapping of conventional syringes was the least reported mechanism of injuries and constituted only 15% of the total injuries and mainly occurred in third year students. The most frequent injuries among student nurses were during disposal of the needle. Conclusion: Less NSIs occur when using safety syringes. A non-recapping policy with immediate disposal of either the conventional or safety syringe systems after injection would prevent all clearance-related NSIs sustained by nurses. To avoid NSIs, education plays a vital role particularly with effective implementation of the change to safety syringes with appropriate training.

  7. Comparison of design features and mechanical properties of commercially available Veress needles.

    Science.gov (United States)

    Schramel, Johannes P; Kindslehner, Angelika; Bockstahler, Barbara A; Dupré, Gilles P

    2017-10-01

    To compare design features and mechanical properties of 13 commercially available Veress needles (VN). In vitro biomechanical study. Veress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. Veress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as mean ± SD or median (range). Physical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20° and 40° were identified. Reusable VN weigh more (24.9 ± 2.2 g) than disposable designs (6.0 ± 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 ± 0.08 Nmm -1 and 0.94 ± 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 ± 0.29 N and 2.77 ± 0.54 N to move to the proximal end of the bevel. Commercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used. © 2017 The American College of Veterinary Surgeons.

  8. The cellularity yield of three different 22-gauge endoscopic ultrasound fine needle aspiration needles.

    Science.gov (United States)

    Othman, Mohamed O; Abdelfatah, Mohamed M; Padilla, Osvaldo; Hussinat, Maha; Elhanafi, Sherif; Eloliby, Mohamed; Torabi, Alireza; Hakim, Nawar; Boman, Darius A

    2017-05-01

    Endoscopic ultrasound (EUS) fine needle aspiration (FNA) is an integral part in the diagnosis of pancreatic, intestinal and extra-intestinal masses or lesions. There is no clear data on the superiority of the core biopsy needle over standard 22-gauge needles. The aim of this study is to prospectively compare the cellularity yield of three commonly used 22-gauge FNA needles available in the US market. This is a prospective, randomized study comparing the cellularity yield of three commercially available EUS needles (two standard FNA needles and core biopsy needle). Two blinded pathologists evaluated the cytology specimens based on an already agreed upon cytology score. We included adult patients (18-80 years old) who presented to our endoscopy unit for FNA of pancreatic or extrapancreatic masses. 109 patients (57 F, 52 M) were recruited to the study, 88 lesions were pancreatic lesions. 39 patients were recruited in the EZ Shot 2™ group, 36 in the Procore ® group and 34 in the Expect™ group. The average cellularity score and the mean number of passes (SD) were not different between the three needles; P = 0.91 and P = 0.16, respectively. There was no difference between the three needles in obtaining an onsite diagnosis (P = 0.627) and no difference in reported adverse events between the three groups. The cellularity yields, the mean number of passes and reported adverse events were similar in the three compared 22-gauge needles. Diagn. Cytopathol. 2017;45:426-432. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. HLW disposal dilemma

    International Nuclear Information System (INIS)

    Andrei, V.; Glodeanu, F.

    2003-01-01

    The radioactive waste is an inevitable residue from the use of radioactive materials in industry, research and medicine, and from the operation of generating electricity nuclear power stations. The management and disposal of such waste is therefore an issue relevant to almost all countries. Undoubtedly the biggest issue concerning radioactive waste management is that of high level waste. The long-lived nature of some types of radioactive wastes and the associated safety implications of disposal plans have raised concern amongst those who may be affected by such facilities. For these reasons the subject of radioactive waste management has taken on a high profile in many countries. Not one Member State in the European Union can say that their high level waste will be disposed of at a specific site. Nobody can say 'that is where it is going to go'. Now, there is a very broad consensus on the concept of geological disposal. The experts have little, if any doubt that we could safely dispose of the high level wastes. Large sectors of the public continue to oppose to most proposals concerning the siting of repositories. Given this, it is increasingly difficult to get political support, or even political decisions, on such sites. The failure to advance to the next step in the waste management process reinforces the public's initial suspicion and resistance. In turn, this makes the political decisions even harder. In turn, this makes the political decisions even harder. The management of spent fuel from nuclear power plant became a crucial issue, as the cooling pond of the Romanian NPP is reaching saturation. During the autumn of 2000, the plant owner proceeded with an international tendering process for the supply of a dry storage system to be implemented at the Cernavoda station to store the spent fuel from Unit 1 and eventually from Unit 2 for a minimum period of 50 years. The facility is now in operation. As concern the disposal of the spent fuel, the 'wait and see

  10. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  11. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  12. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  13. Geological disposal of nuclear waste

    International Nuclear Information System (INIS)

    1979-01-01

    Fourteen papers dealing with disposal of high-level radioactive wastes are presented. These cover disposal in salt deposits, geologic deposits and marine disposal. Also included are papers on nuclear waste characterization, transport, waste processing technology, and safety analysis. All of these papers have been abstracted and indexed

  14. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  15. Preliminary disposal limits, plume interaction factors, and final disposal limits

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-01-11

    In the 2008 E-Area Performance Assessment (PA), each final disposal limit was constructed as the product of a preliminary disposal limit and a plume interaction factor. The following mathematical development demonstrates that performance objectives are generally expected to be satisfied with high confidence under practical PA scenarios using this method. However, radionuclides that experience significant decay between a disposal unit and the 100-meter boundary, such as H-3 and Sr-90, can challenge performance objectives, depending on the disposed-of waste composition, facility geometry, and the significance of the plume interaction factor. Pros and cons of analyzing single disposal units or multiple disposal units as a group in the preliminary disposal limits analysis are also identified.

  16. Radium bearing waste disposal

    International Nuclear Information System (INIS)

    Tope, W.G.; Nixon, D.A.; Smith, M.L.; Stone, T.J.; Vogel, R.A.; Schofield, W.D.

    1995-01-01

    Fernald radium bearing ore residue waste, stored within Silos 1 and 2 (K-65) and Silo 3, will be vitrified for disposal at the Nevada Test Site (NTS). A comprehensive, parametric evaluation of waste form, packaging, and transportation alternatives was completed to identify the most cost-effective approach. The impacts of waste loading, waste form, regulatory requirements, NTS waste acceptance criteria, as-low-as-reasonably-achievable principles, and material handling costs were factored into the recommended approach

  17. Whither nuclear waste disposal?

    International Nuclear Information System (INIS)

    Cotton, T.A.

    1990-01-01

    With respect to the argument that geologic disposal has failed, I do not believe that the evidence is yet sufficient to support that conclusion. It is certainly true that the repository program is not progressing as hoped when the Nuclear Waste Policy Act of 1982 established a 1998 deadline for initial operation of the first repository. The Department of Energy (DOE) now expects the repository to be available by 2010, and tat date depends upon a finding that the Yucca Mountain site - the only site that DOE is allowed by law to evaluate - is in fact suitable for use. Furthermore, scientific evaluation of the site to determine its suitability is stopped pending resolution of two lawsuits. However, I believe it is premature to conclude that the legal obstacles are insuperable, since DOE just won the first of the two lawsuits, and chances are good it will win the second. The concept of geologic disposal is still broadly supported. A recent report by the Board on Radioactive Waste Management of the National Research Council noted that 'There is a worldwide scientific consensus that deep geological disposal, the approach being followed in the United States, is the best option for disposing of high-level radioactive waste'. The U.S. Nuclear Regulatory Commission (USNRC) recently implicitly endorsed this view in adopting an updated Waste Confidence position that found confidence that a repository could be available in the first quarter of the next century - sufficient time to allow for rejection of Yucca Mountain and evaluation of a new site

  18. Unconsciously penetrated foreign body (sewing needle injury

    Directory of Open Access Journals (Sweden)

    Musa Zorlu

    2015-12-01

    Full Text Available The injuries of foreign body in work accidents are often seen in adults. It could be diagnosed in different parts of the body. In this study, a twenty year old woman who had a pain in the left axillary region of the body, a constraint on joint movement coordination center and high fever is not aware of the needle in her body was examined. There was a sewing needle penetrates to pectoralis major muscle at the left axillary region of the body seen in her anterior posterior chest x ray. It was removed under general anesthesia using fluoroscopy. Patients could have different clinical complaints due to the mobile sewing needle in different parts of the body. The questioning of her profession history and physical examination would help for diagnosis of the complaints in the evaluation of patients. [J Contemp Med 2015; 5(4.000: 265-268

  19. Waste and Disposal: Demonstration

    International Nuclear Information System (INIS)

    Neerdael, B.; Buyens, M.; De Bruyn, D.; Volckaert, G.

    2002-01-01

    Within the Belgian R and D programme on geological disposal, demonstration experiments have become increasingly important. In this contribution to the scientific report 2001, an overview is given of SCK-CEN's activities and achievements in the field of large-scale demonstration experiments. In 2001, main emphasis was on the PRACLAY project, which is a large-scale experiment to demonstrate the construction and the operation of a gallery for the disposal of HLW in a clay formation. The PRACLAY experiment will contribute to enhance understanding of water flow and mass transport in dense clay-based materials as well as to improve the design of the reference disposal concept. In the context of PRACLAY, a surface experiment (OPHELIE) has been developed to prepare and to complement PRACLAY-related experimental work in the HADES Underground Research Laboratory. In 2001, efforts were focussed on the operation of the OPHELIE mock-up. SCK-CEN also contributed to the SELFRAC roject which studies the self-healing of fractures in a clay formation

  20. Disposal of spent fuel

    International Nuclear Information System (INIS)

    Blomeke, J.O.; Ferguson, D.E.; Croff, A.G.

    1978-01-01

    Based on preliminary analyses, spent fuel assemblies are an acceptable form for waste disposal. The following studies appear necessary to bring our knowledge of spent fuel as a final disposal form to a level comparable with that of the solidified wastes from reprocessing: 1. A complete systems analysis is needed of spent fuel disposition from reactor discharge to final isolation in a repository. 2. Since it appears desirable to encase the spent fuel assembly in a metal canister, candidate materials for this container need to be studied. 3. It is highly likely that some ''filler'' material will be needed between the fuel elements and the can. 4. Leachability, stability, and waste-rock interaction studies should be carried out on the fuels. The major disadvantages of spent fuel as a disposal form are the lower maximum heat loading, 60 kW/acre versus 150 kW/acre for high-level waste from a reprocessing plant; the greater long-term potential hazard due to the larger quantities of plutonium and uranium introduced into a repository; and the possibility of criticality in case the repository is breached. The major advantages are the lower cost and increased near-term safety resulting from eliminating reprocessing and the treatment and handling of the wastes therefrom

  1. Greater-confinement disposal

    International Nuclear Information System (INIS)

    Trevorrow, L.E.; Schubert, J.P.

    1989-01-01

    Greater-confinement disposal (GCD) is a general term for low-level waste (LLW) disposal technologies that employ natural and/or engineered barriers and provide a degree of confinement greater than that of shallow-land burial (SLB) but possibly less than that of a geologic repository. Thus GCD is associated with lower risk/hazard ratios than SLB. Although any number of disposal technologies might satisfy the definition of GCD, eight have been selected for consideration in this discussion. These technologies include: (1) earth-covered tumuli, (2) concrete structures, both above and below grade, (3) deep trenches, (4) augered shafts, (5) rock cavities, (6) abandoned mines, (7) high-integrity containers, and (8) hydrofracture. Each of these technologies employ several operations that are mature,however, some are at more advanced stages of development and demonstration than others. Each is defined and further described by information on design, advantages and disadvantages, special equipment requirements, and characteristic operations such as construction, waste emplacement, and closure

  2. Dry needling versus acupuncture: the ongoing debate.

    Science.gov (United States)

    Zhou, Kehua; Ma, Yan; Brogan, Michael S

    2015-12-01

    Although Western medical acupuncture (WMA) is commonly practised in the UK, a particular approach called dry needling (DN) is becoming increasingly popular in other countries. The legitimacy of the use of DN by conventional non-physician healthcare professionals is questioned by acupuncturists. This article describes the ongoing debate over the practice of DN between physical therapists and acupuncturists, with a particular emphasis on the USA. DN and acupuncture share many similarities but may differ in certain aspects. Currently, little information is available from the literature regarding the relationship between the two needling techniques. Through reviewing their origins, theory, and practice, we found that DN and acupuncture overlap in terms of needling technique with solid filiform needles as well as some fundamental theories. Both WMA and DN are based on modern biomedical understandings of the human body, although DN arguably represents only one subcategory of WMA. The increasing volume of research into needling therapy explains its growing popularity in the musculoskeletal field including sports medicine. To resolve the debate over DN practice, we call for the establishment of a regulatory body to accredit DN courses and a formal, comprehensive educational component and training for healthcare professionals who are not physicians or acupuncturists. Because of the close relationship between DN and acupuncture, collaboration rather than dispute between acupuncturists and other healthcare professionals should be encouraged with respect to education, research, and practice for the benefit of patients with musculoskeletal conditions who require needling therapy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Space disposal of nuclear wastes

    Science.gov (United States)

    Priest, C. C.; Nixon, R. F.; Rice, E. E.

    1980-01-01

    The DOE has been studying several options for nuclear waste disposal, among them space disposal, which NASA has been assessing. Attention is given to space disposal destinations noting that a circular heliocentric orbit about halfway between Earth and Venus is the reference option in space disposal studies. Discussion also covers the waste form, showing that parameters to be considered include high waste loading, high thermal conductivity, thermochemical stability, resistance to leaching, fabrication, resistance to oxidation and to thermal shock. Finally, the Space Shuttle nuclear waste disposal mission profile is presented.

  4. Penetrating cardiac injury following sewing needle ingestion.

    Science.gov (United States)

    Sobnach, Sanju; Castillo, Franco; Blanco Vinent, René; Kahn, Delawir; Bhyat, Ahmed

    2011-07-01

    Penetrating cardiac injuries are common in South Africa. Reports describing traumatic lesions to the heart caused by caudo-cranial migration of ingested foreign bodies are however extremely rare. Delayed presentation and intervention are associated with poor outcome in these patients; cardiac tamponade remains the most serious complication. We present the case of a 19 year-old man who sustained a left ventricular injury after intentionally swallowing eight sewing needles. The impacted needle was removed through a median sternotomy and the patient recovered uneventfully. Copyright © 2011 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier B.V. All rights reserved.

  5. [King Injo's disease and burnt needle therapy].

    Science.gov (United States)

    Kim, In-Sook

    2004-12-01

    This paper investigates an interrelationship between burnt needle therapy and King Injo's disease. From 1633 (Year 11 in King Injo's reign) to May 5, 1649 (Year 27 in King Injo's reign), right before his death, King Injo was treated with burnt needles by Yi Hyeongik, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have?Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon ear, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease. The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong derived from her mother, Queen Mother Inmok. Moral justification for King Injo's coup was Gwanghaegun or Prince Gwanghae's immoral conduct toward Queen Mothe Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant rebellions and treasons threatened King Injo. The king suspected that Queen Mother

  6. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  7. Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures

    International Nuclear Information System (INIS)

    Haseler, Luke J.; Sibbitt, Randy R.; Sibbitt, Wilmer L.; Michael, Adrian A.; Gasparovic, Charles M.; Bankhurst, Arthur D.

    2011-01-01

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm 2 ), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.

  8. Etiological studies on needle fungi associated with semimature-tissue needle blight of eastern white pine

    Energy Technology Data Exchange (ETDEWEB)

    Linzon, S.N.

    1968-01-01

    The results of etiological studies on semimature-tissue needle blight (SNB) of eastern white pine (Pinus strobus L.) deny any role to needle fungi as the primary cause. No mycelium was found in newly blighted semimature tissue by either cultural or histological methods. Mycelia of several saprophytic fungi were isolated from the blighted portions of current year needles about 2 weeks after the onset of SNB, and fruit-bodies of different organisms were found to occur both in the interior and on the exterior of blighted needles about 4 weeks after the first occurrence of disease symptoms. The morphological development of apothecia of C. acuum was studied. Hysterothecia of Lophodermium spp. (L. pinastri (Schrad. ex Fr.) Chev. and L. nitens Darker) occurred ubiquitously on fallen white pine needles. Aerial spore trapping showed that ascospores of C. acuum were abundant, those of Lophodermium spp. were prevalent, and those of H. desmazierii were practically non-existent in the area investigated. There was little coincidence between the occurrence of SNB outbreaks and peak populations of air-borne ascospores of these fungi. Ascospore suspensions and needles bearing fructifications of C. acuum and Lophodermium spp. were used to inoculate the newly developing needles of SNB-susceptible and non-susceptible field trees and potted seedlings, but the typical symptoms of SNB did not develop as a result of these inoculations. Two fungicides, captan and Bordeaux mixture, were applied to SNB-susceptible and non-susceptible field trees throughout the growing season, but neither fungicide prevented the symptoms of SNB from appearing on the new needles of susceptible trees at the same time as they appeared on untreated susceptible trees in the area. The fungicidal sprays, however, did prevent saprophyttic fungi from invading blighted portions of the needles. It is concluded from this investigation that SNB is not a disease of fungal origin. 19 references, 17 figures, 3 tables.

  9. Effect of ponderosa pine needle litter on grass seedling survival.

    Science.gov (United States)

    Burt R. McConnell; Justin G. Smith

    1971-01-01

    Hard fescue survival rates were followed for 6 years on four different pine needle treatment plots. Needle litter had a significant effect on initial survival of fescue seedlings, but subsequent losses undoubtedly resulted from the interaction of many factors.

  10. Morphology of jack pine and tamarack needles in dense stands.

    Science.gov (United States)

    Terry F. Strong; J. Zavitkovski

    1978-01-01

    Effects of position in the crown on needle morphology and surface area were studied. Needle length, surface area, and dry weight increased and specific needs area decreased from the lower to the upper third of the crown.

  11. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  12. [Thinking and status of research on acupoint temperature sensor needle].

    Science.gov (United States)

    Xu, Gang; Yang, Hua-yuan; Liu, Tang-yi; Gao, Ming; Hu, Yin-e

    2010-09-01

    ABSTRACT Based on acupoint temperature sensor needle related literatures, the development and the applications of temperature sensor needle and the measuring instrument which is used for measuring the temperature of acupoints are introduced in the present paper. This paper summarizes the basic structure and measuring principle of temperature sensor needle; it also summarizes the hardware and measuring procedures of the measuring instrument. According to the characteristics of the temperature sensor needle, this paper states its broad applications and development trend.

  13. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  14. Atypical chest pain: Needles in a haystack

    African Journals Online (AJOL)

    be needles of the type used for sewing. An electrocardiogram showed a minor interference pattern but no ischaemic changes, and the results of blood tests were all within normal limits. An echocardiogram confirmed the presence of foreign bodies in the myocardium (Fig. 2). There was no evidence of valvular defects.

  15. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  16. Genetics studies involving Swiss needle cast.

    Science.gov (United States)

    R. Johnson; F. Temel; K. Jayawickrama

    2002-01-01

    Three studies were analyzed this year that examined genetic aspects of Swiss needle cast (SNC) tolerance . Families sampled across the Siuslaw National forest showed differences in foliage health traits, but very little of the variation could be explained by environmental or climatic conditions at the parent tree location. Five test sites of the Nehalem series of...

  17. Acylated flavonol glycosides from Larix needles

    NARCIS (Netherlands)

    Niemann, Gerard J.

    2006-01-01

    Kaempferol-3-p-coumarylglucoside (KCG) was isolated from ether fractions of acetone-extracted freeze-dried needles of all larch species investigated. In each case, KCG was found as one of the main flavonoids, whereas often a variety of closely related, acylated flavonoids was present in either

  18. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Background: The increasing prevalence of extrapulmonary manifestation of tuberculosis with the HIV scourge is a cause for concern. Objective: To determine the role of fine needle aspiration cytology (FNAC) in the diagnosis of extrapulmonary tuberculosis. Patients and Methods: This is a consecutive 9-year analysis of ...

  19. The Single Needle Lockstitch Machine. Module 1.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  20. Relationship between needle phobia and dental anxiety

    NARCIS (Netherlands)

    Majstorovic, M.; Veerkamp, J.S.J.

    2004-01-01

    Purpose: This cross-sectional study aimed to explain the nature of needle phobia and its relationship in dental phobic children with evidence on age-related differences. Methods: The study used 2,865 patients (52% boys, 48% girls), 4 to 11 years old (mean=7.18 years). The patient sample included

  1. Nuclear waste disposal site

    International Nuclear Information System (INIS)

    Mallory, C.W.; Watts, R.E.; Sanner, W.S. Jr.; Paladino, J.B.; Lilley, A.W.; Winston, S.J.; Stricklin, B.C.; Razor, J.E.

    1988-01-01

    This patent describes a disposal site for the disposal of toxic or radioactive waste, comprising: (a) a trench in the earth having a substantially flat bottom lined with a layer of solid, fluent, coarse, granular material having a high hydraulic conductivity for obstructing any capillary-type flow of ground water to the interior of the trench; (b) a non-rigid, radiation-blocking cap formed from a first layer of alluvium, a second layer of solid, fluent, coarse, granular material having a high hydraulic conductivity for blocking any capillary-type flow of water between the layer of alluvium and the rest of the cap, a layer of water-shedding silt for directing surface water away from the trench, and a layer of rip-rap over the silt layer for protecting the silt layer from erosion and for providing a radiation barrier; (c) a solidly-packed array of abutting modules of uniform size and shape disposed in the trench and under the cap for both encapsulating the wastes from water and for structurally supporting the cap, wherein each module in the array is slidable movable in the vertical direction in order to allow the array of modules to flexibly conform to variations in the shape of the flat trench bottom caused by seismic disturbances and to facilitate the recoverability of the modules; (d) a layer of solid, fluent, coarse, granular materials having a high hydraulic conductivity in the space between the side of the modules and the walls of the trench for obstructing any capillary-type flow of ground water to the interior of the trench; and (e) a drain and wherein the layer of silt is sloped to direct surface water flowing over the cap into the drain

  2. Radioactive waste disposal

    International Nuclear Information System (INIS)

    Petit, J.C.

    1998-04-01

    A deep gap, reflecting a persisting fear, separates the viewpoints of the experts and that of the public on the issue of the disposal of nuclear WASTES. The history of this field is that of the proliferation with time of spokesmen who pretend to speak in the name of the both humans and non humans involved. Three periods can be distinguished: 1940-1970, an era of contestation and confusion when the experts alone represents the interest of all; 1970-1990, an era of contestation and confusion when spokespersons multiply themselves, generating the controversy and the slowing down of most technological projects; 1990-, an era of negotiation, when viewpoints, both technical and non technical, tend to get closer and, let us be optimistic, leading to the overcome of the crisis. We show that, despite major differences, the options and concepts developed by the different actors are base on two categories of resources, namely Nature and Society, and that the consensus is built up through their 'hydridation'. we show in this part that the perception of nuclear power and, in particular of the underground disposal of nuclear wastes, involves a very deep psychological substrate. Trying to change mentalities in the domain by purely scientific and technical arguments is thus in vain. The practically instinctive fear of radioactivity, far from being due only to lack of information (and education), as often postulated by scientists and engineers, is rooted in archetypical structures. These were, without doubt, reactivated in the 40 s by the traumatizing experience of the atomic bomb. In addition, anthropological-linked considerations allow us to conclude that he underground disposal of wastes is seen as a 'rape' and soiling of Mother Earth. This contributes to explaining, beyond any rationality, the refusal of this technical option by some persons. However, it would naturally be simplistic and counter-productive to limit all controversy in this domain to these psychological aspects

  3. Intracranially Retained Sewing Needle in a Child: Does the Rust on the Needle Have any Implication?

    Science.gov (United States)

    Balak, Naci; Güçlü, Güçlühan; Karaca, Ismail; Aksoy, Sema

    2008-04-01

    A penetrating injury with a sewing needle is a rare phenomenon. The pathophysiological mechanism of late epilepsy after penetrating injuries is not clear. A 10-year-old female child had a seizure. An X-ray study of the skull and the cranial computed tomography scans showed a foreign object retained in the skull cavity. She was intact on neurological examination. Electroencephalogram (EEG) showed that there was bioelectrical disorganization in both hemispheres, being more prominent on the left side. A right posterior frontal median craniotomy was performed in order not to retract the left hemisphere within the interhemispheric fissure and the sewing needle was removed successfully. The sewing needle was rusted. The reason for the patient's seizure, 10 years after the injury, may be the corrosion of the sewing needle and rust formation in this case.

  4. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  5. 21 CFR 884.6100 - Assisted reproduction needles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in in...

  6. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  7. Diversity and identification of fungi associated with needles of Pinus ...

    African Journals Online (AJOL)

    Diversity and identification of fungi associated with needles of Pinus radiata in Tasmania. ... Previous studies of P. radiata have been based on fungal isolation and not direct PCR detection from needles. This research was a component ... Keywords: endophyte, environmental PCR, fungal isolation, MOTU, needle fungi, OTU ...

  8. Hollow needle used to cut metal honeycomb structures

    Science.gov (United States)

    Gregg, E. A.

    1966-01-01

    Hollow needle tool cuts metal honeycomb structures without damaging adjacent material. The hollow needle combines an electrostatic discharge and a stream of oxygen at a common point to effect rapid, accurate metal cutting. The tool design can be varied to use the hollow needle principle for cutting a variety of shapes.

  9. Percutaneous core needle biopsies: The yield in spinal tuberculosis ...

    African Journals Online (AJOL)

    Background. Current recommendations for spinal tuberculosis (TB) not requiring open surgery include core needle biopsy to confirm TB and determine drug sensitivity. International figures show the positive culture yield from core needle biopsies is 50 - 83%. Objectives. To (i) assess the yield of percutaneous needle ...

  10. Conditioning radium needles for long term storage : Sri Lankan experience

    International Nuclear Information System (INIS)

    Ranjith, H.L.A.; Shantha, T.H.S.; Gunaratne, M.G.J.; De Silva, U.W.K.H.; Perera, H.P.H.

    2000-01-01

    Radium the first radioisotope invented by Madame Curie was used for cancer therapy for the intracavitory treatment of cervical cancers and as oral implants etc. Radium needles and other geometries were made in standard strengths and Radium therapy enjoyed a heyday during the 1st half of the 20th century. Radium-226 is a long-lived radioactive material with a half-life of 1600 years. The use of radium was abandoned in the world in 1980s with the invention of short lived radioactive materials offering remote after loading systems which minimise radiation protection and waste disposal problems associated with long lived radioactive materials. This paper reports the conditioning procedure of the spent radium sources for long term storage (less than 20 years) and transport to national/ international stores if needed. The dose received by those involved in this exercise is also discussed in terms of radiation protection. The Ra was contained for long term storage according to international radiation safety regulations with a surface dose of less than 2 mSv per hour in a conditioned package having 17.5 GBq activity and can be transported to national/international stores if needed. The highest dose received during the exercise is well within the recommended dose limits for occupational exposures (20 and 500 mSv per year) for whole body and extremities respectively

  11. Patterns of lymphadenopathy on fine needle aspiration cytology in eastern Nepal

    Directory of Open Access Journals (Sweden)

    N Mainali

    2015-09-01

    Full Text Available BACKGROUND: Lymphadenopathy is a commonly encountered clinical problem. Fine needle aspiration cytology offers the alternative of an immediate, preliminary, although not always specific diagnosis with little trauma and cost, thus providing ample information for further management and reduce the amount of open biopsy.MATERIAL AND METHODS:  FNAC was performed using 21 gauge needle attached with 10ml disposable needle. Slides were prepared, two were air dried and stained with field stain where as two were fixed in ethanol and was stained with PAP stain. One slide was stained with Ziehl-Neelson stain. Field and PAP stained slide were reviewed and diagnosed by Pathologist.RESULT: Out of the 225 patients, reactive lymphadenitis was the most common diagnosis (54.2%, followed by tubercular lymphadenitis (33.44%. Among the age group percentage of tubercular lymphadenitis was more in 210-30 years of age.  Majority of the metastatic carcinoma was in cervical region, comprising mainly squamous cell carcinoma.CONCLUSION: Reactive lymphadenitis was the most common cause of lymphadenopathy especially in case of children. In case of older population, definite pathology for lymph node enlargement was found in most of the cases. Hence FNAC is warranted in lymphadenopathy, as it is simple yet of great diagnostic value.

  12. Disposal - practical problems

    International Nuclear Information System (INIS)

    Hycnar, J.; Pinko, L.

    1995-01-01

    Most Polish power plants have stockyards for storage of fly ash and slag. This paper describes the: methods of fly ash and slag storage used, methods of conveying the waste to the stockpiles (by railway cars, trucks, belt conveyors or hydraulically); construction of wet stockyards and dry stockyards and comparison of the ash dumped, development of methods of ash disposal in mine workings; composition and properties of fly ash and slag from hard coal; and the effects of ash storage yards on the environment (by leaching of trace elements, dust, effect on soils, and noise of machinery). 16 refs., 3 figs., 6 tabs

  13. HLW Disposal System Development

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J. W.; Choi, H. J.; Lee, J. Y. (and others)

    2007-06-15

    A KRS is suggested through design requirement analysis of the buffer and the canister which are the constituent of disposal system engineered barrier and HLW management plans are proposed. In the aspect of radionuclide retention capacity, the thickness of the buffer is determined 0.5m, the shape to be disc and ring and the dry density to be 1.6 g/cm{sup 3}. The maximum temperature of the buffer is below 100 .deg. which meets the design requirement. And bentonite blocks with 5 wt% of graphite showed more than 1.0 W/mK of thermal conductivity without the addition of sand. The result of the thermal analysis for proposed double-layered buffer shows that decrease of 7 .deg. C in maximum temperature of the buffer. For the disposal canister, the copper for the outer shell material and cast iron for the inner structure material is recommended considering the results analyzed in terms of performance of the canisters and manufacturability and the geochemical properties of deep groundwater sampled from the research area with granite, salt water intrusion, and the heavy weight of the canister. The results of safety analysis for the canister shows that the criticality for the normal case including uncertainty is the value of 0.816 which meets subcritical condition. Considering nation's 'Basic Plan for Electric Power Demand and Supply' and based on the scenario of disposing CANDU spent fuels in the first phase, the disposal system that the repository will be excavated in eight phases with the construction of the Underground Research Laboratory (URL) beginning in 2020 and commissioning in 2040 until the closure of the repository is proposed. Since there is close correlation between domestic HLW management plans and front-end/back-end fuel cycle plans causing such a great sensitivity of international environment factor, items related to assuring the non-proliferation and observing the international standard are showed to be the influential factor and acceptability

  14. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  15. Mine tailings disposal

    International Nuclear Information System (INIS)

    Gonzales, P.A.; Adams, B.J.

    1980-06-01

    The hydrologic evaluation of mine tailings disposal sites after they are abandoned is considered in relation to their potential environmental impact on a long term basis. There is a direct relation between the amounts and types of water leaving a disposal site and the severity of the potential damage to the environment. The evaluation of the relative distribution of the precipitation reaching the ground into evaporation, runoff and infiltration is obtained for a selected site and type of tailings material whose characteristics and physical properties were determined in the soils laboratory. A conceptual model of the hydrologic processes involved and the corresponding mathematical model were developed to simulate the physical system. A computer program was written to solve the set of equations forming the mathematical model, considering the physical properties of the tailings and the rainfall data selected. The results indicate that the relative distribution of the precipitation depends on the surface and upper layer of the tailings and that the position of the groundwater table is governed by the flow through the bottom of the profile considered. The slope of the surface of the mass of tailings was found to be one of the principal factors affecting the relative distribution of precipitation and, therefore, the potential pollution of the environment

  16. Geoenvironment and waste disposal

    International Nuclear Information System (INIS)

    1983-07-01

    Within the activities planned by UNESCO in its Water and Earth Science programme, an interdisciplinary meeting on geology and environment was scheduled by this organization to be held by the beginning of 1983. At this meeting it was intended to consider geological processes in the light of their interaction and influence on the environment with special emphasis on the impact of various means of waste disposal on geological environment and on man-induced changes in the geological environment by mining, human settlements, etc. Considering the increasing interest shown by the IAEA in the field, through environmental studies, site studies, and impact studies for nuclear facilities and particularly nuclear waste disposal, UNESCO expressed the wish to organize the meeting jointly so as to take into account the experience gained by the Agency, and in order to avoid any duplication in the activities of the two organizations. This request was agreed to by the IAEA Secretariat and as a result, the meeting was organized by both organizations and held at IAEA Headquarters in Vienna from 21-23 March 1983. The report of this meeting is herewith presented

  17. Disposal of radioactive waste material

    International Nuclear Information System (INIS)

    Cairns, W.J.; Burton, W.R.

    1984-01-01

    A method of disposal of radioactive waste consists in disposing the waste in trenches dredged in the sea bed beneath shallow coastal waters. Advantageously selection of the sites for the trenches is governed by the ability of the trenches naturally to fill with silt after disposal. Furthermore, this natural filling can be supplemented by physical filling of the trenches with a blend of absorber for radionuclides and natural boulders. (author)

  18. Diaper area and disposable diapers.

    Science.gov (United States)

    Erasala, G N; Romain, C; Merlay, I

    2011-01-01

    Since the 1960s, cloth diapers have been replaced by disposable diapers. The evolution of healthier skin in the diaper area has been demonstrated in parallel to that of disposable diapers. The improvements of disposable diapers--fit, dryness, comfort--have been based on the understanding of factors playing a role in the development of diaper dermatitis. Copyright © 2011 S. Karger AG, Basel.

  19. Dual mode fuel injector with one piece needle valve member

    Science.gov (United States)

    Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby

    2005-01-18

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.

  20. Report on radioactive waste disposal

    International Nuclear Information System (INIS)

    1993-01-01

    The safe management of radioactive wastes constitutes an essential part of the IAEA programme. A large number of reports and conference proceedings covering various aspects of the subject have been issued. The Technical Review Committee on Underground Disposal (February 1988) recommended that the Secretariat issue a report on the state of the art of underground disposal of radioactive wastes. The Committee recommended the need for a report that provided an overview of the present knowledge in the field. This report covers the basic principles associated with the state of the art of near surface and deep geological radioactive waste disposal, including examples of prudent practice, and basic information on performance assessment methods. It does not include a comprehensive description of the waste management programmes in different countries nor provide a textbook on waste disposal. Such books are available elsewhere. Reviewing all the concepts and practices of safe radioactive waste disposal in a document of reasonable size is not possible; therefore, the scope of this report has been limited to cover essential parts of the subject. Exotic disposal techniques and techniques for disposing of uranium mill tailings are not covered, and only brief coverage is provided for disposal at sea and in the sea-bed. The present report provides a list of references to more specialized reports on disposal published by the IAEA as well as by other bodies, which may be consulted if additional information is sought. 108 refs, 22 figs, 2 tabs

  1. Lakeview, Oregon, Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management (LM), Washington, DC (United States); Hall, Steve [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-03-01

    9.1 Compliance Summary The Lakeview, Oregon, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site was inspected September 16 and 17, 2015. Other than some ongoing concern with erosion-control rock riprap degradation, the disposal cell was in good condition. Some minor fence repairs and vegetation removal, and minor erosion repair work along the west site fence is planned. Inspectors identified no other maintenance needs or cause for a follow-up or contingency inspection. Disposal cell riprap is evaluated annually to ensure continued long-term protection of the cell from erosion during a severe precipitation event. Degradation of the rock riprap was first observed at the site in the mid-1990s. Rock gradation monitoring of the riprap on the west side slope has been performed as part of the annual inspection since 1997 to determine the mean diameter (D50) value. As prescribed by the monitoring procedure, the rock monitoring is routinely conducted at random locations. However, at the U.S. Nuclear Regulatory Commission’s (NRC’s) request, the 2015 rock monitoring approach deviated from the normal procedure by using a pre-established monitoring grid in a subset area of the west side slope. This changed the monitoring approach from random sampling to biased sampling. The D50 value measured during the 2015 gradation monitoring is 2.39 inches, which falls below the original D50 design size range of 2.7–3.9 inches for the Type B size side slope riprap. At NRC’s request, rock durability monitoring was added to the gradation monitoring in 2009 to monitor durability by rock type. Results of the 2015 durability monitoring showed that74 percent of the total rock sampled is durability class code A rock with an assigned durability class of “highly durable” or durability class code B “durable” rock, and that over 90 percent of the 3-inch or larger rock is durability class code A or B. The rock durability

  2. NUTRIENTS CONCENTRATION AND RETRANSLOCATION IN THE Pinus taeda L. NEEDLES

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-03-01

    Full Text Available Aiming at evaluating nutrients concentration and retranslocation in the Pinus taeda L. needles, this study was developed in two stands, in native grass area and in second rotation area, with same species and same age (7.5 years old in Cambará do Sul, RS. The needles were collected in plants in four orthogonal points (South, North, East and West, sampled new needles, mature needles and old needles. The material was dried in a stove, milled and chemically analyzed (macro and micronutrients. The concentrations of N, P, K, B, Cu and Zn had decreased, of Ca, Fe and Mn increased, and the Mg and S have remained constant with the age of the needles. The retranslocation rate (old-new needles was more than 50% for most nutrients, except for Mn and Fe, showed that cumulative effect and the Ca reference element.

  3. Needle phobia: etiology, adverse consequences, and patient management.

    Science.gov (United States)

    Sokolowski, Chester J; Giovannitti, Joseph A; Boynes, Sean G

    2010-10-01

    Needle phobia has profound health, dental, societal, and legal implications, and severe psychological, social, and physiologic consequences. There is genetic evidence for the physiologic response to needle puncture, and a significant familial psychological component, showing evidence of inheritance. Needle phobia is also a learned behavior. The dental practitioner must recognize patients with needle phobia before the administration of local anesthetics to identify patients who are potentially reactive and to prevent untoward sequelae. Needle phobia is highly associated with avoidance behavior, and the dentist must exhibit compassion and respect. To avoid bradycardia, hypotension, unconsciousness, convulsions, and possibly asystole, oral premedication with benzodiazepines or other antianxiety agents must be considered for patients who are needle phobic. Management of needle phobiaeinduced syncope includes perioperative monitoring, oxygen administration, positioning, atropine, and vasopressors. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Toxic waste liquor disposal

    International Nuclear Information System (INIS)

    Burton, W.R.

    1985-01-01

    Toxic waste liquors, especially radio active liquors, are disposed in a sub-zone by feeding down a bore hole a first liquid, then a buffer liquid (e.g. water), then the toxic liquors. Pressure variations are applied to the sub-zone to mix the first liquid and liquors to form gels or solids which inhibit further mixing and form a barrier between the sub-zone and the natural waters in the environment of the sub-zone. In another example the location of the sub-zone is selected so that the environement reacts with the liquors to produce a barrier around the zone. Blind bore holes are used to monitor the sub-zone profile. Materials may be added to the liquor to enhance barrier formation. (author)

  5. Radwaste Disposal Safety Analysis

    International Nuclear Information System (INIS)

    Hwang, Yong Soo; Kang, C. H.; Lee, Y. M.; Lee, S. H.; Jeong, J. T.; Choi, J. W.; Park, S. W.; Lee, H. S.; Kim, J. H.; Jeong, M. S.

    2010-02-01

    For the purpose of evaluating annual individual doses from a potential repository disposing of radioactive wastes from the operation of the prospective advanced nuclear fuel cycle facilities in Korea, the new safety assessment approaches are developed such as PID methods. The existing KAERI FEP list was reviewed. Based on these new reference and alternative scenarios are developed along with a new code based on the Goldsim. The code based on the compartment theory can be applied to assess both normal and what if scenarios. In addition detailed studies on THRC coupling is studied. The oriental biosphere study ends with great success over the completion of code V and V with JAEA. The further development of quality assurance, in the form of the CYPRUS+ enables handy use of it for information management

  6. Radioactive mixed waste disposal

    International Nuclear Information System (INIS)

    Jasen, W.G.; Erpenbeck, E.G.

    1993-02-01

    Various types of waste have been generated during the 50-year history of the Hanford Site. Regulatory changes in the last 20 years have provided the emphasis for better management of these wastes. Interpretations of the Atomic Energy Act of 1954 (AEA), the Resource Conservation and Recovery Act of 1976 (RCRA), and the Hazardous and Solid Waste Amendments (HSWA) have led to the definition of radioactive mixed wastes (RMW). The radioactive and hazardous properties of these wastes have resulted in the initiation of special projects for the management of these wastes. Other solid wastes at the Hanford Site include low-level wastes, transuranic (TRU), and nonradioactive hazardous wastes. This paper describes a system for the treatment, storage, and disposal (TSD) of solid radioactive waste

  7. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  8. A plasma needle generates nitric oxide

    International Nuclear Information System (INIS)

    Stoffels, E; Gonzalvo, Y Aranda; Whitmore, T D; Seymour, D L; Rees, J A

    2006-01-01

    Generation of nitric oxide (NO) by a plasma needle is studied by means of mass spectrometry. The plasma needle is an atmospheric glow generated by a radio-frequency excitation in a mixture of helium and air. This source is used for the treatment of living tissues, and nitric oxide may be one of the most important active agents in plasma therapy. Efficient NO generation is of particular importance in the treatment of cardiovascular diseases. Mass spectrometric measurements have been performed under various plasma conditions; gas composition in the plasma and conversion of feed gases (nitrogen and oxygen) into other species has been studied. Up to 30% of the N 2 and O 2 input is consumed in the discharge, and NO has been identified as the main conversion product

  9. A simultaneous comparison of acupuncture needle and insulated needle sphenoidal electrodes for detection of anterior temporal spikes.

    Science.gov (United States)

    Chu, N S

    1992-01-01

    Uninsulated acupuncture needles have been used as sphenoidal electrodes, but the issue of insulation has not been adequately addressed. In this report, acupuncture needles and insulated needle sphenoidal electrodes were simultaneously used to compare the rate of spike detection, spike amplitude and distribution of maximal spikes from eight spike foci in seven patients with temporal lobe epilepsy. When compared to the insulated needle electrode, the acupuncture needle electrode was equally effective in spike detection, but spike amplitudes tended to be smaller and maximal spikes were less frequently encountered. Thus, insulation has an influence on the spikes recorded by the acupuncture needle sphenoidal electrode. However, the overall effect appears to be not sufficiently different from the insulated needle electrode for the purpose of detecting anterior temporal spikes in outpatient EEG recordings for the diagnosis of temporal lobe epilepsy.

  10. A retractable barb needle for drug darts

    Directory of Open Access Journals (Sweden)

    G.L. van Rooyen

    1973-07-01

    Full Text Available The mechanism and action of a new retractable barbneedle for drug darts are described. This dart needle is particularly successful in obviating unnecessary flight reactions andtrauma in darted animals, and facilitates the complete injection of the drug dose before the barb is retracted and the dart is dislogded from the animal. The whole process is completed within a few seconds and the expended dart can usually be retrieved in the immediate vicinity where the animal was darted.

  11. Argentina's radioactive waste disposal policy

    International Nuclear Information System (INIS)

    Palacios, E.

    1986-01-01

    The Argentina policy for radioactive waste disposal from nuclear facilities is presented. The radioactive wastes are treated and disposed in confinement systems which ensure the isolation of the radionucles for an appropriate period. The safety criteria adopted by Argentina Authorities in case of the release of radioactive materials under normal conditions and in case of accidents are analysed. (M.C.K.) [pt

  12. Nuclear waste disposal in space

    Science.gov (United States)

    Burns, R. E.; Causey, W. E.; Galloway, W. E.; Nelson, R. W.

    1978-01-01

    Work on nuclear waste disposal in space conducted by the George C. Marshall Space Flight Center, National Aeronautics and Space Administration, and contractors are reported. From the aggregate studies, it is concluded that space disposal of nuclear waste is technically feasible.

  13. Chemical Waste Management and Disposal.

    Science.gov (United States)

    Armour, Margaret-Ann

    1988-01-01

    Describes simple, efficient techniques for treating hazardous chemicals so that nontoxic and nonhazardous residues are formed. Discusses general rules for management of waste chemicals from school laboratories and general techniques for the disposal of waste or surplus chemicals. Lists specific disposal reactions. (CW)

  14. Underground disposal of radioactive wastes

    International Nuclear Information System (INIS)

    1981-01-01

    This report is an overview document for the series of IAEA reports dealing with underground waste disposal to be prepared in the next few years. It provides an introduction to the general considerations involved in implementing underground disposal of radioactive wastes. It suggests factors to be taken into account for developing and assessing waste disposal concepts, including the conditioned waste form, the geological containment and possible additional engineered barriers. These guidelines are general so as to cover a broad range of conditions. They are generally applicable to all types of underground disposal, but the emphasis is on disposal in deep geological formations. Some information presented here may require slight modifications when applied to shallow ground disposal or other types of underground disposal. Modifications may also be needed to reflect local conditions. In some specific cases it may be that not all the considerations dealt with in this book are necessary; on the other hand, while most major considerations are believed to be included, they are not meant to be all-inclusive. The book primarily concerns only underground disposal of the wastes from nuclear fuel cycle operations and those which arise from the use of isotopes for medical and research activities

  15. Disposal of Old Printed Journals

    Indian Academy of Sciences (India)

    2018-02-28

    Feb 28, 2018 ... Indian Academy of Sciences intends to dispose of old journals, on “as is and where is" basis. Interested parties may submit their price quotations in the prescribed format on or before. 28 February 2018 indicating rate per kilogram for each category of the item, proposed for disposal. The cost of application is ...

  16. Korean Reference HLW Disposal System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heui Joo; Lee, J. Y.; Kim, S. S. (and others)

    2008-03-15

    This report outlines the results related to the development of Korean Reference Disposal System for High-level radioactive wastes. The research has been supported around for 10 years through a long-term research plan by MOST. The reference disposal method was selected via the first stage of the research during which the technical guidelines for the geological disposal of HLW were determined too. At the second stage of the research, the conceptual design of the reference disposal system was made. For this purpose the characteristics of the reference spent fuels from PWR and CANDU reactors were specified, and the material and specifications of the canisters were determined in term of structural analysis and manufacturing capability in Korea. Also, the mechanical and chemical characteristics of the domestic Ca-bentonite were analyzed in order to supply the basic design parameters of the buffer. Based on these parameters the thermal and mechanical analysis of the near-field was carried out. Thermal-Hydraulic-Mechanical behavior of the disposal system was analyzed. The reference disposal system was proposed through the second year research. At the final third stage of the research, the Korean Reference disposal System including the engineered barrier, surface facilities, and underground facilities was proposed through the performance analysis of the disposal system.

  17. Safe disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Hooker, P.; Metcalfe, R.; Milodowski, T.; Holliday, D.

    1997-01-01

    A high degree of international cooperation has characterized the two studies reported here which aim to address whether radioactive waste can be disposed of safely. Using hydrogeochemical and mineralogical surveying techniques earth scientists from the British Geological Survey have sought to identify and characterise suitable disposal sites. Aspects of the studies are explored emphasising their cooperative nature. (UK)

  18. Melter Disposal Strategic Planning Document

    Energy Technology Data Exchange (ETDEWEB)

    BURBANK, D.A.

    2000-09-25

    This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.

  19. Disposable diapers: safe and effective.

    Science.gov (United States)

    Singh, Namita; Purthi, P K; Sachdev, Anupam; Gupta, Suresh

    2003-09-01

    Nappy rash is a common problem in infants due to their thinner skin, wetness, heat and friction under cloth nappy, fecal enzymes and alkaline urine. The disposable diapers containing Super Absorbent Material (SAM) reduce the incidence of nappy rash. SAM quickly absorbs urine and keeps the skin dry. Also disposable diapers prevent fecal contamination by absorbing the urine and containing stools.

  20. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  1. Pulsed photoelectric field emission from needle cathodes

    CERN Document Server

    Hernandez-Garcia, C

    2002-01-01

    Experiments have been carried out to measure the current emitted by tungsten needles with 1-mu m tip radius operated up to 50 kV. This corresponds to electric fields in the order of 10 sup 9 to 10 sup 1 sup 0 V/m. The needles were illuminated with 10-ns laser pulses at 532, 355 and 266 nm. The laser intensity was varied from 10 sup 1 sup 0 to 10 sup 1 sup 2 W/m sup 2 , limited by damage to the needle tip. The observed quantum efficiency depends on the wavelength and the electric field, approaching unity at the highest electric fields when illuminated at 266 nm. Peak currents up to 100 mA were observed in nanosecond pulses, corresponding to an estimated brightness of 10 sup 1 sup 6 A/m sup 2 sr. Since the current is controlled by the laser intensity, with only a weak voltage dependence, these cathodes can be used for infrared and ultraviolet tabletop free-electron lasers and other applications that demand short electron-beam pulses with high brightness.

  2. Liver abscess due to sewing needle perforation.

    Science.gov (United States)

    Jutte, Ewoud; Cense, Huib

    2010-08-03

    A 45-year-old female was admitted to the hospital with a 1-week history of right upper abdominal pain and nausea. Ultrasonography showed a thickened duodenum with infiltration. Subsequent gastroscopy did not reveal any abnormalities. CT scan showed a foreign body perforation at the duodenum and a liver abscess (Fig. 1A,B). A diagnostic laparoscopy was performed. During the operation, the abscess was drained (Fig. 2A,B) and a sewing needle was removed (Fig. 3A,B). The patient claimed to have no recollection of swallowing the needle and made a quick recovery. Although rare, gastrointestinal perforations due to ingested foreign bodies most frequently occur at ileocecal, rectosigmoid, and duodenal regions[1]. Sewing needle perforations into the liver have been reported in children, adults, and psychiatric cases. Symptoms can vary from mild gastric pain to signs of peritonitis[2]. "Wait and see" is recommended for asymptomatic patients with no complications. Symptomatic patients (e.g., liver abscess) need surgical intervention[1,2,3].

  3. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  4. Operating needle exchange programmes in the hills of Thailand.

    Science.gov (United States)

    Gray, J

    1995-01-01

    Injecting drug use is increasingly markedly amongst the ethnically distinct Hilltribe peoples of northern Thailand in the notorious 'Golden Triangle'. This paper reports on the establishing of needle exchanges in three remote Hilltribe villages, examining the success and the failure. Up to 60% of adult males and a smaller percentage of adult females in these villages are habitual users of opium and/or heroin. Overcoming initial concern that needle distribution would encourage increased use, the villagers themselves have assumed responsibility for much of the needle exchange operation. Prior to the introduction of the needle exchanges all the injecting drug users were sharing needles. This behaviour changed significantly with the introduction of the exchanges. Reluctance on the part of locally-based government officials to participate fully in the programme created difficulties in maintaining needle supplies which saw some resumption in needle sharing. HIV seroprevalence rates amongst the tested injecting drug users remained fairly stable at 33% in February 1993 and 32% in February 1994. The conclusion can be drawn that needle exchange programmes are operable in the Hilltribe context and that they are the best means of limiting HIV/AIDS transmission amongst injecting drug users and the wider community. The success of needle exchange programmes, however, is dependent upon co-operation from various government agencies and non-government agencies, in addition to the local communities. To this end mechanisms ensuring co-operation, training, monitoring and evaluation need to be developed alongside the introduction of needle exchanges.

  5. Initial experience using a radiofrequency powered transseptal needle.

    Science.gov (United States)

    Smelley, Matthew P; Shah, Dipak P; Weisberg, Ian; Kim, Susan S; Lin, Albert C; Beshai, John F; Burke, Martin C; Knight, Bradley P

    2010-04-01

    The purpose of this study was to determine the safety and efficacy of using a novel radiofrequency (RF) powered transseptal needle to perform transseptal puncture (TSP). TSP was performed in 35 consecutive patients undergoing left-sided catheter ablation (mean age = 51 years; male = 71%) using a RF powered transseptal needle (NRG, Adult Large and Standard Curve C1, 71 cm, Baylis Medical Company, Inc.). Prior TSP had been performed in 34% of patients. The transseptal apparatus was positioned with the tip of the dilator engaged in the fossa ovalis. RF energy was delivered to the tip of the transseptal needle using a proprietary RF generator at 10 W for 2 seconds as gentle pressure was applied to the needle. In 5 of the 41 TSPs, the needle crossed into the left atrium before RF energy was delivered. In 35 of the remaining 36 punctures, the needle was successfully advanced into the left atrium after application of RF current. In 1 patient, the TSP with the powered needle was unsuccessful but was accomplished using a standard needle. The only complication was a transient right atrial thrombus, which occurred in 2 patients. A radiofrequency powered transseptal needle can be used to perform TSP safely and successfully without the need for significant mechanical force, even in patients who have undergone TSP previously. Additional studies are needed to determine whether a powered transseptal needle should be used routinely.

  6. Tendon needling for treatment of tendinopathy: A systematic review.

    Science.gov (United States)

    Krey, David; Borchers, James; McCamey, Kendra

    2015-02-01

    To summarize the best available evidence to determine if tendon needling is an effective treatment for tendinopathy. Data source. Medline and Cochrane Databases through November 2013. Utilizing the search terms tendinopathy, needle, needling, tenotomy, dry needling, needling tendon, needle fenestration, and tendon fenestration, 17 articles were identified through our systematic literature search. Of these, 4 studies met the inclusion criteria. Four independent reviewers reviewed the articles. The study results and generated conclusions were agreed upon. The studies that were included in this review suggest that tendon needling improves patient reported outcomes in patients with tendinopathy. In 2 studies evaluating tendon needling in lateral epicondylosis, one showed an improvement in a subjective visual analogue scale score of 34% (significant change > 25%) from baseline at 6 months. The other showed an improvement of 56.1% in a visual analogue scale score from baseline. In 1 study evaluating tendon needling in addition to eccentric therapy for Achilles tendinosis, the subjective Victorian Institute of Sport Assessment-Achilles (VISA-A) score improved by 19.9 (significant change > 10) (95% CI, 13.6-26.2) from baseline. In 1 study evaluating tendon needling in rotator cuff tendinosis, the subjective shoulder pain and disability index showed statistical significant improvement from baseline at 6 months (P tendinopathy. There is a trend that shows that the addition of autologous blood products may further improve theses outcomes.

  7. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  8. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  9. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  10. Unreviewed Disposal Question Evaluation: Waste Disposal In Engineered Trench #3

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, L. L.; Smith, F. G. III; Flach, G. P.; Hiergesell, R. A.; Butcher, B. T.

    2013-07-29

    Because Engineered Trench #3 (ET#3) will be placed in the location previously designated for Slit Trench #12 (ST#12), Solid Waste Management (SWM) requested that the Savannah River National Laboratory (SRNL) determine if the ST#12 limits could be employed as surrogate disposal limits for ET#3 operations. SRNL documented in this Unreviewed Disposal Question Evaluation (UDQE) that the use of ST#12 limits as surrogates for the new ET#3 disposal unit will provide reasonable assurance that Department of Energy (DOE) 435.1 performance objectives and measures (USDOE, 1999) will be protected. Therefore new ET#3 inventory limits as determined by a Special Analysis (SA) are not required.

  11. Fluoroscopically guided transforaminal epidural dry needling for lumbar spinal stenosis using a specially designed needle

    Directory of Open Access Journals (Sweden)

    Ahn Kang

    2010-08-01

    Full Text Available Abstract Background This report describes the methodological approach and clinical application of a minimally invasive intervention to treat lumbar spinal stenosis (LSS. Methods Thirty-four patients with LSS underwent fluoroscopically guided transforaminal epidural dry needling using a specially designed flexed Round Needle. The needle was inserted 8-12 cm lateral to the midline at the level of the stenosis and advanced to a position between the anterior side of the facet joint and pedicle up to the outer-third of the pedicle. The needle was advanced medially and backed laterally within a few millimetres along the canal side of the inferior articular process between the facet joint and pedicle. The procedure was completed when a marked reduction in resistance was felt at the tip of the needle. The procedure was performed bilaterally at the level of the stenosis. Results The average follow-up period was 12.9 ± 1.1 months. The visual analogue scale (VAS pain score was reduced from 7.3 ± 2.0 to 4.6 ± 2.5 points, the Oswestry Disability Index (ODI score decreased from 41.4 ± 17.2 to 25.5 ± 12.6% and the average self-rated improvement was 52.6 ± 33.1%. The VAS scores indicated that 14 (41.2% patients reported a "good" to "excellent" treatment response, while 11 (32.4% had a "good" to "excellent" treatment response on the ODI and 22 (64.7% had a "good" to "excellent" treatment response on the self-rated improvement scale. Conclusions These results suggest that fluoroscopically guided transforaminal epidural dry needling is effective for managing LSS.

  12. Radwaste disposal drum centrifuge

    International Nuclear Information System (INIS)

    Rubin, L.S.; Deltete, C.P.; Crook, M.R.

    1988-01-01

    The drum or processing bowl of the DDC becomes the disposal container when the filling operation is completed. Rehandling of the processed resin is eliminated. By allowing the centrifugally compacted resin to remain in the processing container, extremely efficient waste packaging can be achieved. The dewatering results and volume reductions reported during 1986 were based upon laboratory scale testing sponsored by the Electric Power Research Institute (EPRI) and the Department of Energy (DOE). Since the publication of these preliminary results, additional testing using a full-scale prototype DDC has been completed, again under the auspices of the DOE. Full-scale testing has substantiated the results of earlier testing and has formed the basis for preliminary discussions with the U.S. Nuclear Regulatory Commission (NRC) regarding DDC licensing for radioactive applications. A comprehensive Topical Report and Process Control Program is currently being prepared for submittal to the NRC for review under a utility licensing action. Detailed cost-benefit analyses for actual plant operations have been prepared to substantiate the attractiveness of the DDC. Several methods to physically integrate a DDC into a nuclear power plant have also been developed

  13. Geological disposal system development

    International Nuclear Information System (INIS)

    Kang, Chul Hyung; Kuh, J. E.; Kim, S. K. and others

    2000-04-01

    Spent fuel inventories to be disposed of finally and design base spent fuel were determined. Technical and safety criteria for a geological repository system in Korea were established. Based on the properties of spent PWR and CANDU fuels, seven repository alternatives were developed and the most promising repository option was selected by the pair-wise comparison method from the technology point of view. With this option preliminary conceptual design studies were carried out. Several module, e.g., gap module, congruent release module were developed for the overall assessment code MASCOT-K. The prominent overseas databases such as OECD/NEA FEP list were are fully reviewed and then screened to identify the feasible ones to reflect the Korean geo-hydrological conditions. In addition to this the well known scenario development methods such as PID, RES were reviewed. To confirm the radiological safety of the proposed KAERI repository concept the preliminary PA was pursued. Thermo-hydro-mechanical analysis for the near field of repository were performed to verify thermal and mechanical stability for KAERI repository system. The requirements of buffer material were analyzed, and based on the results, the quantitative functional criteria for buffer material were established. The hydraulic and swelling property, mechanical properties, and thermal conductivity, the organic carbon content, and the evolution of pore water chemistry were investigated. Based on the results, the candidate buffer material was selected

  14. Researching radioactive waste disposal

    International Nuclear Information System (INIS)

    Feates, F.; Keen, N.

    1976-01-01

    At present it is planned to use the vitrification process to convert highly radioactive liquid wastes, arising from nuclear power programme, into glass which will be contained in steel cylinders for storage. The UKAEA in collaboration with other European countries is currently assessing the relative suitability of various natural geological structures as final repositories for the vitrified material. The Institute of Geological Sciences has been commissioned to specify the geological criteria that should be met by a rock structure if it is to be used for the construction of a repository though at this stage disposal sites are not being sought. The current research programme aims to obtain basic geological data about the structure of the rocks well below the surface and is expected to continue for at least three years. The results in all the European countries will then be considered so that the United Kingdom can choose a preferred method for isolating their wastes. It is only at that stage that a firm commitment may be made to select a site for a potential repository, when a far more detailed scientific research study will be instituted. Heat transfer problems and chemical effects which may occur within and around repositories are being investigated and a conceptual design study for an underground repository is being prepared. (U.K.)

  15. Geological disposal system development

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chul Hyung; Kuh, J. E.; Kim, S. K. and others

    2000-04-01

    Spent fuel inventories to be disposed of finally and design base spent fuel were determined. Technical and safety criteria for a geological repository system in Korea were established. Based on the properties of spent PWR and CANDU fuels, seven repository alternatives were developed and the most promising repository option was selected by the pair-wise comparison method from the technology point of view. With this option preliminary conceptual design studies were carried out. Several module, e.g., gap module, congruent release module were developed for the overall assessment code MASCOT-K. The prominent overseas databases such as OECD/NEA FEP list were are fully reviewed and then screened to identify the feasible ones to reflect the Korean geo-hydrological conditions. In addition to this the well known scenario development methods such as PID, RES were reviewed. To confirm the radiological safety of the proposed KAERI repository concept the preliminary PA was pursued. Thermo-hydro-mechanical analysis for the near field of repository were performed to verify thermal and mechanical stability for KAERI repository system. The requirements of buffer material were analyzed, and based on the results, the quantitative functional criteria for buffer material were established. The hydraulic and swelling property, mechanical properties, and thermal conductivity, the organic carbon content, and the evolution of pore water chemistry were investigated. Based on the results, the candidate buffer material was selected.

  16. Disposable diapers and infant skin.

    Science.gov (United States)

    Ueda, H; Takase, M

    1987-01-01

    In an experiment on skin rash caused by diapers, adult skin was used to compare the effects of disposable diapers (A; Pampers), conventional disposable diapers (B), and cotton diapers. Pieces of each type of diaper measuring 2 X 2 cm and containing 0.2 ml saline solution were pasted on forearm skin for 5 h. Water content of the corneum was measured with an impedance meter 1 h after the pieces were removed. Results were excellent for diapers A and B: there were no significant differences observed in water content of the corneum when A and B were compared with conventional cotton diapers. The advantages of disposable diapers were confirmed in infants.

  17. FFTF disposable solid waste cask

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J. D.; Goetsch, S. D.

    1983-01-01

    Disposal of radioactive waste from the Fast Flux Test Facility (FFTF) will utilize a Disposable Solid Waste Cask (DSWC) for the transport and burial of irradiated stainless steel and inconel materials. Retrievability coupled with the desire for minimal facilities and labor costs at the disposal site identified the need for the DSWC. Design requirements for this system were patterned after Type B packages as outlined in 10 CFR 71 with a few exceptions based on site and payload requirements. A summary of the design basis, supporting analytical methods and fabrication practices developed to deploy the DSWC is provided in this paper.

  18. FFTF disposable solid waste cask

    International Nuclear Information System (INIS)

    Thomson, J.D.; Goetsch, S.D.

    1983-01-01

    Disposal of radioactive waste from the Fast Flux Test Facility (FFTF) will utilize a Disposable Solid Waste Cask (DSWC) for the transport and burial of irradiated stainless steel and inconel materials. Retrievability coupled with the desire for minimal facilities and labor costs at the disposal site identified the need for the DSWC. Design requirements for this system were patterned after Type B packages as outlined in 10 CFR 71 with a few exceptions based on site and payload requirements. A summary of the design basis, supporting analytical methods and fabrication practices developed to deploy the DSWC is provided in this paper

  19. Disposable diapers: a hygienic alternative.

    Science.gov (United States)

    Kamat, Maithili; Malkani, Ram

    2003-11-01

    The use of disposable diapers has offered improved health care benefits. Urine and fecal matter leakage from the cloth nappies and the hand-to-mouth behavior in infants leads to many illnesses with a feco-oral mode of transmission. Also, the tender skin of the infant is more prone to nappy rash. The modern age disposable diapers, when compared to cloth nappy, have displayed a superior ability in containment of urine and feces, thereby reducing contamination and transmission of infection. Also disposable diapers contain Super Absorbent Material (SAM) that successfully reduces the incidence of nappy rash.

  20. A simple percutaneous inserter for radiopaque gold seeds used in radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Hay, K.D.; Hindley, A.; Sharp, I.

    1998-01-01

    Percutaneous insertion of a radiopaque marker is an important technique used in radiotherapy planning for both external-beam and brachytherapy. It is of particular importance in the oral cavity. We describe the construction and use of a simple inserter for 'cold' gold seeds manufactured from a commercialiy available Becton Dickinson Brand 5-mL disposable syrinqe and a Becton Dickinson Brand 18 G 11/2 TW (1.25 x 38 mm) hypodermic needle. Copyright (1998) Blackwell Science Pty Ltd

  1. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  2. Needle-Stick Injury among Health Care Workers in Hemodialysis Units in Nigeria: A Multi-Center Study

    Directory of Open Access Journals (Sweden)

    CO Amira

    2014-01-01

    Full Text Available Background: Needle-stick and sharps injuries carry the risk of infection and are occupational hazards for all health care professionals involved in clinical care. Objective: To determine the frequency and factors contributing to needle-stick injury (NSI among health care workers of dialysis units in Lagos, Nigeria. Methods: Data were obtained by anonymous, self-reporting questionnaire from staff of 4 hemodialysis units between October and December 2011. Information on demographics, job category and duration, details of NSI in the past, kind of activity and procedure under which the NSI occurred, if injury was reported, vaccination status of staff, and post-exposure treatment received were obtained. Results: The study population included 38 (37.3% doctors, 42 nurses (41.2%, 14 (13.7% dialysis technicians and 8 (7.8% ancillary staff. There were 39 (38.2% males. The mean±SD age of the study population was 34.4±8.3 years. 25 (24.5% staff had suffered NSI in the last 12 months and 41 (40.2% in their entire working career. The most common activity leading to NSI was recapping of needles (45%, improper disposal of needles (30%, and venous cannulation and setting of drips (27.5%. NSI was significantly (p=0.016 higher among those with work experience between 6 and 10 years than others. Hollow bore needles were responsible for 82.9% of the NSIs. Only 15 (37% respondents reported their NSI to their unit head or designated officer in order to get medical advice. Conclusion: In Lagos, Nigeria, NSI is common among hemodialysis staff and is under-reported. Many NSIs can be prevented by adhering to the practice of universal precautions as well as education of staff on such precautionary methods.

  3. Transbronchial needle aspiration "by the books"

    Directory of Open Access Journals (Sweden)

    Kupeli Elif

    2011-01-01

    Full Text Available Background : Training for advanced bronchoscopic procedures is acquired during the interventional pulmonology (IP Fellowship. Unfortunately a number of such programs are small, limiting dissemination of formal training. Objective : We studied success of conventional transbronchial needle aspiration (C-TBNA in the hands of physicians without formal IP training. Methods : A technique of C-TBNA was learned solely from the literature, videos and practicing on inanimate models at "Hands-On" courses. Conventional TBNA with 21 and/or 19 gauge Smooth Shot Needles (Olympus® , Japan was performed on consecutive patients with undiagnosed mediastinal lymphadenopathy. Results : Thirty-four patients (male 23, mean age 54.9 ± 11.8 years underwent C-TBNA. Twenty-two patients had nodes larger than 20 mms. Suspected diagnoses were malignancy in 20 and nonmalignant conditions in 14. Final diagnoses were malignancy 17, sarcoidosis 4, reactive lymph nodes 12, and tuberculosis 1. Final diagnosis was established by C-TBNA in 14 (11 malignancy, 3 sarcoidosis; yield 41.1%, mediastinoscopy in 14, transthoracic needle aspiration in 3, peripheral lymph node biopsies in 2 and by endobronchial biopsy in 1. Nodal size had an impact on outcome (P = 0.000 while location did not (P = 0.33. C-TBNA was positive in 11/20 when malignancy was suspected (yield 55%, while 3/14 when benign diagnosis was suspected (yield 21.4% (P = 0.05. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 66.6%, 100%, 100%, 65%, and 79.4%, respectively. There were no complications or scope damage. Conclusion : Conventional-TBNA can be learned by the books and by practicing on inanimate models without formal training and results similar to those published in the literature could be achieved.

  4. Radioactive waste processing and disposal

    International Nuclear Information System (INIS)

    1980-01-01

    This compilation contains 4144 citations of foreign and domestic reports, journal articles, patents, conference proceedings, and books pertaining to radioactive waste processing and disposal. Five indexes are provided: Corporate Author, Personal Author, Subject, Contract Number, and Report Number

  5. Foreign Body in the Liver: Sewing Needle

    Directory of Open Access Journals (Sweden)

    Yeliz Akturk

    2013-10-01

    Full Text Available Foreign body ingestion is a frequent clinical problem. Many foreign bodies go through the alimentary system without causing any damage. Incisory and penetrative foreign bodies may migrate and stay in the neighboring organs after perforation. Nevertheless this is an unusual case. The foreign bodies may be found outside of the gastrointestinal system and computed tomography is helpfull for localization and to identify their relationship between surrounding tissues. Here we report of a case in which a swallowed needle perforates duodenum and penetrates the liver.

  6. Evaluation of waste disposal safety

    International Nuclear Information System (INIS)

    Pedersen, A.

    1982-01-01

    Requirements of the Environmental Agency for high-radioactive waste disposal are, that natural transport mechanisms must not contribute to biospheric pollution, that violent natural phenomena cannot release any biospheric pollution and that human activities will be very limited and health hazard insignificant compared to other man-created risks. Investigation of radioaactive waste disposal in Mors salt deposits has proved these requirements to be satisfied. (EG)

  7. Financing of radioactive waste disposal

    International Nuclear Information System (INIS)

    Reich, J.

    1989-01-01

    Waste disposal is modelled as a financial calculus. In this connection the particularity is not primarily the dimension to be expected of financial requirement but above all the uncertainty of financial requirement as well as the ecological, socio-economic and especially also the temporal dimension of the Nuclear Waste Disposal project (disposal of spent fuel elements from light-water reactors with and without reprocessing, decommissioning = safe containment and disposal of nuclear power plants, permanent isolation of radioactive waste from the biosphere, intermediate storage). Based on the above mentioned factors the author analyses alternative approaches of financing or financial planning. He points out the decisive significance of the perception of risks or the evaluation of risks by involved or affected persons - i.e. the social acceptance of planned and designed waste disposal concepts - for the achievement and assessment of alternative solutions. With the help of an acceptance-specific risk measure developed on the basis of a mathematical chaos theory he illustrates, in a model, the social influence on the financing of nuclear waste disposal. (orig./HP) [de

  8. Space disposal of nuclear wastes

    International Nuclear Information System (INIS)

    Priest, C.C.; Nixon, R.F.; Rice, E.E.

    1980-01-01

    It is proposed that certain types of high-level nuclear wastes obtained from the Purex process be injected into space with the aid of Space Shuttles uprated with liquid rocket boosters able to deliver about 45,000 kg to low Earth orbit, a reusable cryogenic orbit-transfer vehicle (OTV) for Earth escape, and an expendable storable-propellant vehicle for the solar-orbit insertion maneuver. It appears feasible to employ the space option for disposing of Purex wastes, but the mass of waste for space disposal is still large and thus consideration needs to be given to additional processes that will selectively separate only the most hazardous radionuclides for disposal in space. Space disposal should present a lower long-term risk to human health than options calling for disposal on Earth. But short-term risks may not be lower than for terrestrial disposal. They must be acceptable for policy-makers to act on the space option. 37 refs

  9. Near-surface land disposal

    International Nuclear Information System (INIS)

    Kittel, J.H.

    1989-01-01

    The Radioactive Waste Management Handbook provides a comprehensive, systematic treatment of nuclear waste management. Near-Surface Land Disposal, the first volume, is a primary and secondary reference for the technical community. To those unfamiliar with the field, it provides a bridge to a wealth of technical information, presenting the technology associated with the near-surface disposal of low or intermediate level wastes. Coverage ranges from incipient planning to site closure and subsequent monitoring. The book discusses the importance of a systems approach during the design of new disposal facilities so that performance objectives can be achieved; gives an overview of the radioactive wastes cosigned to near-surface disposal; addresses procedures for screening and selecting sites; and emphasizes the importance of characterizing sites and obtaining reliable geologic and hydrologic data. The planning essential to the development of particular sites (land acquisition, access, layout, surface water management, capital costs, etc.) is considered, and site operations (waste receiving, inspection, emplacement, closure, stabilization, etc.) are reviewed. In addition, the book presents concepts for improved confinement of waste, important aspects of establishing a monitoring program at the disposal facility, and corrective actions available after closure to minimize release. Two analytical techniques for evaluating alternative technologies are presented. Nontechnical issues surrounding disposal, including the difficulties of public acceptance are discussed. A glossary of technical terms is included

  10. Relationship between buckling of acupuncture needles and the handle type.

    Science.gov (United States)

    Zhang, Claire Shuiqing; Pannirselvan, Muthu; Xue, Charlie Changli; Xie, Yi Min

    2014-10-01

    Most popular single-use acupuncture needles consist of a stainless steel shaft with a handle made of copper coil or plastic stick. To determine the strengths and weaknesses of these two handle types for needle buckling. The buckling load for acupuncture needles with these two different handle types was determined using a digital scale, and the stiffness of stainless steel wires used in different types of acupuncture needles was measured using a Dynamic Mechanical Analysis machine. This study showed that an acupuncture needle with a copper coil handle was far more susceptible to buckling than a needle with a plastic stick handle. The average buckling force of acupuncture needles with plastic stick handles was 46.7% higher than that with copper coil handles for needles of 0.25 mm×30 mm, and 30.8% higher for needles of 0.25 mm×60 mm. Replacing a copper coil handle with a plastic stick handle could save about 100 tonnes of copper wires and 20 million metres of medical grade stainless steel wire a year worldwide. The results from this study suggest that the common practice of using coiled copper for handles on acupuncture needles should be re-evaluated. Replacing a copper coil handle with a plastic stick handle would significantly reduce needle buckling and improve patient comfort and safety. This would also reduce the consumption of copper and medical grade stainless steel wire considerably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Artifact-reduced imaging of biopsy needles with 2D multispectral imaging.

    Science.gov (United States)

    Weber, Hans; Hargreaves, Brian A; Daniel, Bruce L

    2017-12-29

    Magnetic resonance (MR) guidance for biopsy procedures requires high intrinsic soft-tissue contrast. However, artifacts induced by the metallic needle can reduce its localization and require low-susceptibility needle materials with poorer cutting performance. In a proof of concept, we demonstrate the feasibility of 2D multispectral imaging (2DMSI) for both needle tracking and for needle artifact reduction for more precise needle localization and to enable the usage of needle materials with higher susceptibility. We applied 2DMSI for imaging of MR-compatible biopsy needles, conventional stainless-steel needles, and mixed-material needles and compared it to conventional techniques. In addition, we exploited intrinsic off-resonance information for passive needle tracking. 2DMSI achieved a stronger reduction of the needle artifact compared to conventional techniques. For the mixed-material needles, the artifact was reduced to a level below that for MR-compatible needles with conventional imaging. The passive tracking also improved the ability to pinpoint the needle. 2DMSI is promising for both needle tracking and artifact-reduced imaging of biopsy needles for a more precise needle localization. 2DMSI may be particularly promising for needles inducing large distortions or for targeting of small lesions. In addition, it may enable the use of needle materials with higher susceptibility and potentially better sampling performance. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Preschool Needle Pain Responding: Establishing 'Normal'.

    Science.gov (United States)

    Waxman, Jordana A; DiLorenzo, Miranda G; Pillai Riddell, Rebecca R; Flora, David B; Greenberg, Saul; Garfield, Hartley

    2017-06-01

    The current study sets forth to provide descriptive data for preschool vaccination pain responding as well as examine longitudinal relationships over early childhood. Growth mixture modeling was first used to describe stable subgroups of preschoolers on the basis of their pain response patterns over 2-minutes post-needle. Secondly, a parallel-process growth curve model was used to assess the stability of acute pain responding from 12 months of age to preschool age. Specifically, we examined whether preschool pain-related distress or regulation could be predicted from 12-month acute pain responding. Preschool participants were part of a Canadian longitudinal cohort (The Opportunities to Understand Childhood Hurt [OUCH] cohort; N = 302). Growth mixture modeling analyses discerned 3 distinct groups of preschoolers, with an important minority not regulating to low-no pain by 2 minutes post-needle. There were no significant associations between 12-month and preschool pain responding. These results highlight the steep trajectory of development between these different stages of early childhood and the variability of pain responding at the preschool vaccination. This study provides descriptive data for preschool vaccination pain responding as well as examines longitudinal relationships over early childhood. Demonstrating significantly different pain patterns from infancy, 25% of preschoolers are displaying suboptimal regulation trajectories. This considerable minority poses a significant concern because of the established trajectory of phobia onset in middle childhood. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.

  13. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  14. Sub-seabed disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Sivintsaev, Yu.V.

    1990-01-01

    The first stage of investigations of possibility of sub-seabed disposal of long-living intermediate-level radioactive wastes carried out by NIREX (UK) is described. Advantages and disadvantages of sub-seabed disposal of radioactive wastes are considered; regions suitable for disposal, transport means for marine disposal are described. Three types of sub-seabed burials are characterized

  15. Needle Tip Visibility in 3D Ultrasound Images

    NARCIS (Netherlands)

    M. Arif (Muhammad); A. Moelker (Adriaan); T.W. van Walsum (Theo)

    2017-01-01

    textabstractAim: Needle visibility is crucial for effective and safe ultrasound-guided interventional procedures. Several studies have investigated needle visibility in 2D ultrasound imaging, but less information is available for 3D ultrasound imaging, a modality that has great potential for image

  16. Local variations in microfungal populations on Pinus sylvestris needles.

    Science.gov (United States)

    Gourbière, François; Debouzie, Domitien

    2003-10-01

    We studied the fungal colonization of Pinus sylvestris needles in two neighbouring sites, comparing stands of isolated and grouped trees. We observed large variations among the proportions of needles bearing fruit bodies of Cyclaneusma minus, Lophodermium pinastri, Verticicladium trifidum and black lines characteristic of L. pinastri colonization. Variations between sites and within trees were greater than that between stands or between trees. The frequency of L. pinastri colonization was negatively correlated with C. minus fruit body frequency, while the frequency of V. trifidum conidiophores was positively correlated with L. pinastri colonization frequency without fruiting, and negatively correlated with C. minus apothecia frequency. Although L. pinastri black lines and C. minus apothecia were nearly randomly associated on individual needles in each sample, the two fungi occupied different segments when they occupied the same needle. These patterns at needle and sample scales do not explain the negative correlation between the frequencies of these two species observed at larger scales. In each sample, frequency of V. trifidum conidiophores was highest on needles colonized by L. pinastri without fruiting. On individual needles, V. trifidum conidiophores developed on segments colonized by L. pinastri without fruiting, but not on segments bearing fruit bodies of L. pinastri or C. minus. These patterns at needle and sample scales were consistent with the correlations between frequencies observed at larger scales. These results were compared to variations observed with stand age and climate in others studies. The observed variations might result from both microclimate variations and fungal interactions.

  17. Effect of dietary mugwort ( Artemisia vulgaris L.) and pine needle ...

    African Journals Online (AJOL)

    The effects of dietary mugwort and pine needle powder supplementation on growth performance, serum cholesterol, and meat quality of broilers were evaluated in a 35 days feed trial. 200 one day old broilers were randomly allocated to five dietary treatments (0, 1 and 2% mugwort or 1 and 2% pine needle powder) with ...

  18. Effect of vibration frequency on biopsy needle insertion force.

    Science.gov (United States)

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  20. Needle-shaped and platelet growth of borax crystals

    International Nuclear Information System (INIS)

    Takoo, R.K.; Patel, B.R.; Joshi, M.S.

    1983-01-01

    Needle-shaped and platelet growth of borax crystals from solutions is reported. Results of microtopographical studies on both the varieties are discussed. It is suggested that a slow rate of evaporation favours needle growth and a faster rate is conducive to the growth of platelets. (author)

  1. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  2. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  3. Prevalence of needle-stick injuries, blood and body fluids ...

    African Journals Online (AJOL)

    Background: Health care workers are frequently exposed to needle-stick injuries, blood and body fluids in the performance of their duties. Aims and objectives: This study sought to determine the prevalence and pattern of occupational exposure to needle-stick injuries, blood and body fluid contamination among clinical and ...

  4. Prevalence of Needle Stick Injuries among Healthcare Workers in ...

    African Journals Online (AJOL)

    Background: Needle stick injuries represent one of the most important occupational hazards to which health workers are exposed. These injuries result from accidental piercing of the skin and or mucous membranes by sharp objects. Needle stick injuries carry the risk of exposure to blood-borne pathogens, especially ...

  5. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  6. PVA matches human liver in needle-tissue interaction

    NARCIS (Netherlands)

    de Jong, T.L.; Pluymen, L.H.; van Gerwen, D.J.; Kleinrensink, GJ; Dankelman, J.; van den Dobbelsteen, J.J.

    2017-01-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were

  7. ORIGINAL ARTICLES Door-to-needle time for administration of ...

    African Journals Online (AJOL)

    infarction (STEMI) were identified; 161 patients were eligible for the study. The median door-to-needle time achieved was 54 minutes (range 13 - 553 mins). A door-to-needle time of 30 minutes or less was achieved in 33 (20.5%) patients; 51.3% of the patients arrived by ambulance; 34% of patients had a pre-hospital 12- ...

  8. Darning Needle Impacted in the Male Urethra | Singla | African ...

    African Journals Online (AJOL)

    Foreign bodies of varied nature have been introduced into the urethra to achieve sexual stimulation. We report the case of a long (9.5 cm) darning needle impacted in the urethra of a male patient following urethral masturbation. After a failed trial at endoscopic extraction the needle had to be removed via open surgery.

  9. Importance of Fine Needle Aspiration in Evaluation of Single ...

    African Journals Online (AJOL)

    Background: Improvements in the sensitivity and specificity of biochemical thyroid tests, as well as the development of fine needle aspiration biopsy (FNA) and improved cytological techniques, have dramatically impacted clinical strategies for detecting and treating thyroid disorders. Fine needle aspiration is a safe and ...

  10. Environmental effects of reactor waste disposal alternatives

    International Nuclear Information System (INIS)

    Unruh, C.M.

    1980-05-01

    This present document, Environmental Impact Statement on Management of Commercially Generated Radioactive Waste, describes ten alternative methods for disposal of nuclear wastes and evaluates their anticipated environmental impacts. The ten alternatives are: (1) geologic disposal using conventional mining techniques; (2) chemical resynthesis; (3) very deep hole concept; (4) rock melting concept; (5) island disposal; (6) sub-seabed geologic disposal; (7) ice sheet disposal; (8) reverse-well disposal; (9) partitioning and transmutation; and (10) space disposal. In evaluating the various technical strategies, issues and environmental impacts have been analyzed as best understood currently. Based on the analysis presented here, and in the light of the greater depth of knowledge on geologic disposal, DOE proposes that: (1) the disposal of radioactive wastes in geologic formations can likely be developed and applied with minimal environmental consequences; and (2) therefore the program emphasis should be on the establishment of mined repositories as the operative disposal technology

  11. CT-guided needle puncture for diagnosis and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Takashi; Kaji, Tatsumi; Ashida, Hiroshi; Nakajima, Yasuo; Nosaka, Shunsuke; Kuroki, Kazunori; Kurihara, Yasuyuki; Hara, Akihiko; Ishikawa, Tohru

    1987-12-01

    CT-guided needle puncture was performed in 16 aspiration biopsies, 12 nerve neurolysis, 6 percutaneous treatment such as abscess drainage. CT-guidance was better than fluoroscopic or sonographic control, in dealing with small, deeply-located lesions where precise location of needle is inevitable. We used the slotted 20 gauge thin-walled needle for biopsy, 21 or 22-gauge chiba-needle for other purposes. Over-all accuracy was 93.3 % in aspiration biopsies and technical successful rate in nerve neurolysis was 100 %. Only one pneumothorax was noted as a complication. CT-guided needle puncture was safe and exact, especially when fluoroscopic or sonographic guidance was not possible.

  12. A training system for ultrasound-guided needle insertion procedures.

    Science.gov (United States)

    Zhu, Yanong; Magee, Derek; Ratnalingam, Rish; Kessel, David

    2007-01-01

    Needle placement into a patient body under guidance of ultrasound is a frequently performed procedure in clinical practice. Safe and successful performance of such procedure requires a high level of spatial reasoning and hand-eye co-ordination skills, which must be developed through intensive practice. In this paper we present a training system designed to improve the skills of interventional radiology trainees in ultrasound-guided needle placement procedures. Key issues involved in the system include surface and volumetric registration, solid texture modelling, spatial calibration, and real-time synthesis and rendering of ultrasound images. Moreover, soft tissue deformation caused by the needle movement and needle cutting is realised using a mass-spring-model approach. These have led to a realistic ultrasound simulation system, which has been shown to be a useful tool for the training of needle insertion procedures. Preliminary results of a construct evaluation study indicate the effectiveness and usefulness of the developed training system.

  13. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  14. Waste Water Disposal Design And Management I

    International Nuclear Information System (INIS)

    Yang, Sang Hyeon; Lee, Jung Su

    2004-04-01

    This book gives descriptions of waste water disposal, design and management, which includes design of waterworks and sewerage facility such as preparatory work and building plan, used waste water disposal facilities, waste water disposal plant and industrial waste water disposal facilities, water use of waste water disposal plant and design of pump and pump facilities such as type and characteristic, selection and plan, screening and grit.

  15. 10 CFR 61.51 - Disposal site design for land disposal.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Disposal site design for land disposal. 61.51 Section 61.51 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.51 Disposal site design for land...

  16. 10 CFR 61.52 - Land disposal facility operation and disposal site closure.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Land disposal facility operation and disposal site closure. 61.52 Section 61.52 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.52 Land disposal...

  17. 10 CFR 61.50 - Disposal site suitability requirements for land disposal.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Disposal site suitability requirements for land disposal. 61.50 Section 61.50 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.50 Disposal site...

  18. Tank Waste Disposal Program redefinition

    Energy Technology Data Exchange (ETDEWEB)

    Grygiel, M.L.; Augustine, C.A.; Cahill, M.A.; Garfield, J.S.; Johnson, M.E.; Kupfer, M.J.; Meyer, G.A.; Roecker, J.H. [Westinghouse Hanford Co., Richland, WA (United States); Holton, L.K.; Hunter, V.L.; Triplett, M.B. [Pacific Northwest Lab., Richland, WA (United States)

    1991-10-01

    The record of decision (ROD) (DOE 1988) on the Final Environmental Impact Statement, Hanford Defense High-Level, Transuranic and Tank Wastes, Hanford Site, Richland Washington identifies the method for disposal of double-shell tank waste and cesium and strontium capsules at the Hanford Site. The ROD also identifies the need for additional evaluations before a final decision is made on the disposal of single-shell tank waste. This document presents the results of systematic evaluation of the present technical circumstances, alternatives, and regulatory requirements in light of the values of the leaders and constitutents of the program. It recommends a three-phased approach for disposing of tank wastes. This approach allows mature technologies to be applied to the treatment of well-understood waste forms in the near term, while providing time for the development and deployment of successively more advanced pretreatment technologies. The advanced technologies will accelerate disposal by reducing the volume of waste to be vitrified. This document also recommends integration of the double-and single-shell tank waste disposal programs, provides a target schedule for implementation of the selected approach, and describes the essential elements of a program to be baselined in 1992.

  19. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis.

    Science.gov (United States)

    Facciorusso, Antonio; Stasi, Elisa; Di Maso, Marianna; Serviddio, Gaetano; Ali Hussein, Mohammed Salah; Muscatiello, Nicola

    2017-10-01

    Robust data in favour of a clear superiority of 22 versus 25 Gauge needles for endoscopic ultrasound-guided fine needle aspiration are still lacking. We aimed to compare the diagnostic sensitivity, specificity and safety of these two needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions. A computerized bibliographic search was restricted to randomized controlled trials only. Pooled effects were calculated using a random-effects model and expressed in terms of risk ratio and 95% confidence interval. We analysed seven trials with 689 patients and 732 lesions (295 sampled with 22 Gauge needle, 309 with 25 Gauge needle, and 128 with both needles). A non-significant superiority of 25 Gauge in terms of pooled sensitivity (risk ratio: 0.93, 0.91-0.95 versus 0.89, 0.85-0.94 of 22 Gauge needle; p  = 0.13) and no difference in terms of specificity (1.00, 0.98-1.00 in both groups; p  = 0.85) were observed. Sample adequacy was similar between the two devices (risk ratio: 1.03, 0.99-1.06; p  = 0.15). Very few adverse events were observed and did not impact on patient outcomes. Our meta-analysis reveals non-superiority of 25 Gauge over 22 Gauge; hence no definitive recommendations over the use of one particular device can be made.

  20. Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.

    Science.gov (United States)

    Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert

    2015-10-01

    Many common needle intervention procedures are performed with ultrasound guidance because it is a flexible, cost-effective and widely available intra-operative imaging modality. In a needle insertion procedure with ultrasound guidance, real-time calculation and visualization of the needle trajectory can help to guide the choice of puncture site and needle angle to reach the target depicted in the ultrasound image. We found that it is feasible to calculate the needle trajectory with a single camera mounted directly on the ultrasound transducer by using the needle markings. Higher accuracy is achieved compared with other similar transducer-mounted needle trackers. We used an inexpensive, real-time and easy-to-use tracking method based on an automatic feature extraction algorithm and a closed-form method for pose estimation of the needle. The overall accuracy was 0.94 ± 0.46 mm. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  2. Underground radioactive waste disposal concept

    International Nuclear Information System (INIS)

    Frgic, L.; Tor, K.; Hudec, M.

    2002-01-01

    The paper presents some solutions for radioactive waste disposal. An underground disposal of radioactive waste is proposed in deep boreholes of greater diameter, fitted with containers. In northern part of Croatia, the geological data are available on numerous boreholes. The boreholes were drilled during investigations and prospecting of petroleum and gas fields. The available data may prove useful in defining safe deep layers suitable for waste repositories. The paper describes a Russian disposal design, execution and verification procedure. The aim of the paper is to discuss some earlier proposed solutions, and present a solution that has not yet been considered - lowering of containers with high level radioactive waste (HLW) to at least 500 m under the ground surface.(author)

  3. Depleted uranium disposal options evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hertzler, T.J.; Nishimoto, D.D.; Otis, M.D. [Science Applications International Corp., Idaho Falls, ID (United States). Waste Management Technology Div.

    1994-05-01

    The Department of Energy (DOE), Office of Environmental Restoration and Waste Management, has chartered a study to evaluate alternative management strategies for depleted uranium (DU) currently stored throughout the DOE complex. Historically, DU has been maintained as a strategic resource because of uses for DU metal and potential uses for further enrichment or for uranium oxide as breeder reactor blanket fuel. This study has focused on evaluating the disposal options for DU if it were considered a waste. This report is in no way declaring these DU reserves a ``waste,`` but is intended to provide baseline data for comparison with other management options for use of DU. To PICS considered in this report include: Retrievable disposal; permanent disposal; health hazards; radiation toxicity and chemical toxicity.

  4. Deep borehole disposal of plutonium

    International Nuclear Information System (INIS)

    Gibb, F. G. F.; Taylor, K. J.; Burakov, B. E.

    2008-01-01

    Excess plutonium not destined for burning as MOX or in Generation IV reactors is both a long-term waste management problem and a security threat. Immobilisation in mineral and ceramic-based waste forms for interim safe storage and eventual disposal is a widely proposed first step. The safest and most secure form of geological disposal for Pu yet suggested is in very deep boreholes and we propose here that the key to successful combination of these immobilisation and disposal concepts is the encapsulation of the waste form in small cylinders of recrystallized granite. The underlying science is discussed and the results of high pressure and temperature experiments on zircon, depleted UO 2 and Ce-doped cubic zirconia enclosed in granitic melts are presented. The outcomes of these experiments demonstrate the viability of the proposed solution and that Pu could be successfully isolated from its environment for many millions of years. (authors)

  5. Depleted uranium disposal options evaluation

    International Nuclear Information System (INIS)

    Hertzler, T.J.; Nishimoto, D.D.; Otis, M.D.

    1994-05-01

    The Department of Energy (DOE), Office of Environmental Restoration and Waste Management, has chartered a study to evaluate alternative management strategies for depleted uranium (DU) currently stored throughout the DOE complex. Historically, DU has been maintained as a strategic resource because of uses for DU metal and potential uses for further enrichment or for uranium oxide as breeder reactor blanket fuel. This study has focused on evaluating the disposal options for DU if it were considered a waste. This report is in no way declaring these DU reserves a ''waste,'' but is intended to provide baseline data for comparison with other management options for use of DU. To PICS considered in this report include: Retrievable disposal; permanent disposal; health hazards; radiation toxicity and chemical toxicity

  6. Hip Pain: Dry Needling Versus Cortisone Injections.

    Science.gov (United States)

    2017-04-01

    Greater trochanteric pain syndrome (GTPS) is chronic, intermittent pain and tenderness on the outside of the hip. The medical community once thought that a swollen hip bursa was the source of such pain, which led to the use of corticosteroid injections to the bursa to help decrease swelling and pain. However, researchers now believe that injuries to the muscles and tendons around the hip are the actual cause of this pain, and that inflammation is often not involved. A study published in the April 2017 issue of JOSPT explores dry needling as an alternative to cortisone injections to reduce pain and improve function in patients with GTPS. J Orthop Sports Phys Ther 2017;47(4):240. doi:10.2519/jospt.2017.0504.

  7. [Improvement of sonographic visualization of cannula needle tips by alignment of the needle lumen : In vitro investigation of established needle tip forms].

    Science.gov (United States)

    Schwemmer, U; Geppert, T; Steinfeldt, T; Wunder, C

    2015-10-13

    In the context of ultrasound-guided peripheral nerve blocks (regional anesthesia), clear visualization of the needle tip and the target structure are mandatory for the performance of a safe puncture and injection. The purpose of this in vitro study was to analyze the visualization of different forms of needle tips and calibers of cannulas in a phantom simulating human tissue, with the help of a standardized image analysis system. Different depths and angles of the puncture needle in relation to the ultrasound probe were tested. Cannula needles established for use in regional anesthesia with different surfaces, diameters and needle tip form in 23 different combinations were analyzed. A gelatine-based phantom was used to simulate human tissue. The standardized visualization of the needle tip with the ultrasound probe was performed in plane at different angles (30°, 45° and 60°), depths of penetration (1 cm, 2 cm and 3 cm) and two different alignments of the cannula needle lumen to the ultrasound probe (0° and 180°). The screenshots of the ultrasound pictures were analyzed by quantifying the pixel brightness around the needle tip (region of interest) with a standardized software (score 0-255). In this study 1104 ultrasound images of cannula needles were analyzed. Diminished scores (reduced pixel brightness) of the needle tips were documented with increasing distance from the ultrasound probe. Comparison of punctures at angles of 30° and 45° showed no differences in needle tip visibility (same scores) but punctures at an angle of 60° were poorly visualized compared with 30° and 45° (mean scores 87.90 ± 11.60 vs. 78.40 ± 12.07, p cannula lumen towards the ultrasound probe (0°) was significantly more easily visualized when compared with the reverse alignment of 180° (mean scores 86.90 ± 12.74 vs. 84.80 ± 11.66, p = 0.003, respectively). No differences in visibility were detected between the different cannula needle diameters

  8. Knowledge and Self-Reported Practice of Insulin Injection Device Disposal among Diabetes Patients in Gondar Town, Ethiopia: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Abebe Basazn Mekuria

    2016-01-01

    Full Text Available Background. Incorrect sharp disposal practices may expose the public to needle-stick injuries. The present study aimed at assessing the knowledge and practice of diabetic patients towards insulin injection device disposal in Gondar town, Ethiopia. Methods. A cross-sectional study was employed on insulin requiring diabetes patients who visited the diabetes clinic at Gondar University Referral Hospital (GURH from February 1 to March 28, 2016. Frequencies, percentages, and ANOVA (analysis of variance and Student’s t-test were used to analyze variables. Results. About half of the participants (49.5% had poor knowledge towards safe insulin injection waste disposal. More than two-thirds (80.7% of respondents had poor practice and 64.3% of respondents did not put insulin needle and lancets into the household garbage. 31% of respondents threw sharps on street when they travel outside. Respondents living in urban areas had a higher mean of knowledge and practice score than those who live in rural area. Conclusions. This study revealed that knowledge and practice of diabetic patients were low towards safe insulin injection waste disposal in study area. Healthcare providers should also be aware of safe disposing system and counsel patients on appropriate disposal of used syringes.

  9. Needle-free delivery of measles virus vaccine to the lower respiratory tract of non-human primates elicits optimal immunity and protection.

    Science.gov (United States)

    de Swart, Rik L; de Vries, Rory D; Rennick, Linda J; van Amerongen, Geert; McQuaid, Stephen; Verburgh, R Joyce; Yüksel, Selma; de Jong, Alwin; Lemon, Ken; Nguyen, D Tien; Ludlow, Martin; Osterhaus, Albert D M E; Duprex, W Paul

    2017-01-01

    Needle-free measles virus vaccination by aerosol inhalation has many potential benefits. The current standard route of vaccination is subcutaneous injection, whereas measles virus is an airborne pathogen. However, the target cells that support replication of live-attenuated measles virus vaccines in the respiratory tract are largely unknown. The aims of this study were to assess the in vivo tropism of live-attenuated measles virus and determine whether respiratory measles virus vaccination should target the upper or lower respiratory tract. Four groups of twelve cynomolgus macaques were immunized with 10 4 TCID 50 of recombinant measles virus vaccine strain Edmonston-Zagreb expressing enhanced green fluorescent protein. The vaccine virus was grown in MRC-5 cells and formulated with identical stabilizers and excipients as used in the commercial MV EZ vaccine produced by the Serum Institute of India. Animals were immunized by hypodermic injection, intra-tracheal inoculation, intra-nasal instillation, or aerosol inhalation. In each group six animals were euthanized at early time points post-vaccination, whereas the other six were followed for 14 months to assess immunogenicity and protection from challenge infection with wild-type measles virus. At early time-points, enhanced green fluorescent protein-positive measles virus-infected cells were detected locally in the muscle, nasal tissues, lungs, and draining lymph nodes. Systemic vaccine virus replication and viremia were virtually absent. Infected macrophages, dendritic cells and tissue-resident lymphocytes predominated. Exclusive delivery of vaccine virus to the lower respiratory tract resulted in highest immunogenicity and protection. This study sheds light on the tropism of a live-attenuated measles virus vaccine and identifies the alveolar spaces as the optimal site for respiratory delivery of measles virus vaccine.

  10. TMI abnormal wastes disposal options

    International Nuclear Information System (INIS)

    Ayers, A.L. Jr.

    1984-03-01

    A substantial quantity of high beta-gamma/high-TRU contaminated wastes are expected from cleanup activities of Unit 2 of the Three Mile Island Nuclear Power Station. Those wastes are not disposable because of present regulatory constraints. Therefore, they must be stored temporarily. This paper discusses three options for storage of those wastes at the Idaho National Engineering Laboratory: (1) storage in temporary storage casks; (2) underground storage in vaults; and (3) storage in silos at a hot shop. Each option is analyzed and evaluated. Also included is a discussion of future disposal strategies, which might be pursued when a suitable federal or commercial repository is built

  11. Salt formations offer disposal alternative

    International Nuclear Information System (INIS)

    Funderburk, R.

    1990-01-01

    This paper discusses how three U.S. firms are spending millions to permit and build underground disposal sites in salt formations. These companies claim salt is the ideal geological medium for holding hazardous wastes. Two Texas locations and one in Michigan have been targeted as future sites for hazardous waste disposal. The Michigan site, outside Detroit, is a former salt mine 2,000 feet beneath the Ford Motor Co. (Detroit) assembly works in Dearborn. Both Texas sites are atop salt domes---one east and one west of Houston

  12. Sewage sludge disposal in Austria

    International Nuclear Information System (INIS)

    Koch, F.

    1997-01-01

    Sewage systems serve about 70% of the Austrian population, producing 6 million m 3 of sewage sludge per year with a dry matter content of 4-5%. At present about 52% of this sludge is disposed of in land fills, 33% is incinerated, and only about 15 % is used in agriculture. Although agricultural utilization is becoming increasingly important, several problems, especially those related to public opinion, need to be resolved before increased use will be possible. In this paper, wastewater treatment and sewage-sludge production in Austria, and problems associated with sludge disposal are discussed. (author)

  13. Waste disposal developments within BNFL

    International Nuclear Information System (INIS)

    Johnson, L.F.

    1989-01-01

    British Nuclear Fuels plc has broad involvement in topics of radioactive waste generation, treatment, storage and disposal. The Company's site at Drigg has been used since 1959 for the disposal of low level waste and its facilities are now being upgraded and extended for that purpose. Since September 1987, BNFL on behalf of UK Nirex Limited has been managing an investigation of the Sellafield area to assess its suitability for deep underground emplacement of low and intermediate level radioactive wastes. An approach will be described to establish a partnership with the local community to work towards a concept of monitored, underground emplacement appropriate for each waste category. (author)

  14. Development of automatic blood extraction device with a micro-needle for blood-sugar level measurement

    Science.gov (United States)

    Kawanaka, Kaichiro; Uetsuji, Yasutomo; Tsuchiya, Kazuyoshi; Nakamachi, Eiji

    2008-12-01

    In this study, a portable type HMS (Health Monitoring System) device is newly developed. It has features 1) puncturing a blood vessel by using a minimally invasive micro-needle, 2) extracting and transferring human blood and 3) measuring blood glucose level. This miniature SMBG (Self-Monitoring of Blood Glucose) device employs a syringe reciprocal blood extraction system equipped with an electro-mechanical control unit for accurate and steady operations. The device consists of a) a disposable syringe unit, b) a non-disposable body unit, and c) a glucose enzyme sensor. The syringe unit consists of a syringe itself, its cover, a piston and a titanium alloy micro-needle, whose inner diameter is about 100µm. The body unit consists of a linear driven-type stepping motor, a piston jig, which connects directly to the shaft of the stepping motor, and a syringe jig, which is driven by combining with the piston jig and slider, which fixes the syringe jig. The required thrust to drive the slider is designed to be greater than the value of the blood extraction force. Because of this driving mechanism, the automatic blood extraction and discharging processes are completed by only one linear driven-type stepping motor. The experimental results using our miniature SMBG device was confirmed to output more than 90% volumetric efficiency under the driving speed of the piston, 1.0mm/s. Further, the blood sugar level was measured successfully by using the glucose enzyme sensor.

  15. Remote Electromagnetic Vibration of Steerable Needles for Imaging in Power Doppler Ultrasound

    Science.gov (United States)

    Cabreros, Sarah S.; Jimenez, Nina M.; Greer, Joseph D.; Adebar, Troy K.; Okamura, Allison M.

    2015-01-01

    Robotic needle steering systems for minimally invasive medical procedures require complementary medical imaging systems to track the needles in real time. Ultrasound is a promising imaging modality because it offers relatively low-cost, real-time imaging of the needle. Previous methods applied vibration to the base of the needle using a voice coil actuator, in order to make the needle visible in power Doppler ultrasound. We propose a new method for needle tip vibration, using electromagnetic actuation of small permanent magnets placed inside the needle to improve needle tip visibility in power Doppler imaging. Robotic needle insertion experiments using artificial tissue and ex vivo porcine liver showed that the electromagnetic tip vibration method can generate a stronger Doppler response compared to the previous base vibration method, resulting in better imaging at greater needle depth in tissue. It also eliminates previous issues with vibration damping along the shaft of the needle. PMID:26413379

  16. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  17. Return Rates for Needle Exchange Programs: A Common Criticism Answered

    Directory of Open Access Journals (Sweden)

    Ksobiech Kate

    2004-04-01

    Full Text Available Abstract This study searched the available needle exchange program (NEP literature for return rate data. A total of 26 articles were found. The overall worldwide return rate was 90%, although this ranged from a low of 15% to a high of 112%. U.S. NEP return rates were gathered from only eight studies, indicating a clear need for more data, although U.S. return rates were comparable to those from NEPs outside of the U.S. One underlying assumption made by opponents of NEPs is that IDUs will not return needles to the distribution site, thereby potentially increasing the risk of health problems to the surrounding community from exposure to contaminated needles. This study's results suggest that NEPs are relatively successful in taking in used needles, although it is generally unclear where the needles were originally acquired, and if IDUs return their own needles, or are returning needles for a social network. Ways for AIDS Service Organizations to capitalize on these brief encounters with IDUs, as well as public policy implications of the findings, are discussed.

  18. Jet injection devices for the needle-free administration of compounds, vaccines, and other agents.

    Science.gov (United States)

    Logomasini, Mark A; Stout, Richard R; Marcinkoski, Ron

    2013-01-01

    Jet injection involves the use of a needle-free device that delivers a prescribed drug, vaccine, or compound intradermally, subcutaneously, or intramuscularly via high pressure produced by either a carbon-dioxide-filled or nitrogen-filled cartridge or a spring. During that procedure, the injector is held at an angle against the patient's skin, and a very fine stream of liquid medication is forced through a tiny orifice in the device, penetrates the skin in a selected volume ranging from 0.05 mL to 1.0 mL, and is deposited in the underlying tissue. When compared with methods of injection that require a needle, jet injection offers multiple benefits. It can be less painful for the patient, and it enhances compliance, reduces risks such as needlestick injuries and cross-contamination, eliminates the need for "sharps" disposal, and enables (with minimal training) the reliable, reproducible, and accurate delivery of medication. Patient convenience is also a factor: Jet injectors are designed for self-medication as well as professional use. It must be remembered, however, that treatment via jet injection is not always painless. Because of their formulations, some medications and vaccines produce a burning or stinging sensation, whether they are administered with a jet injector or a needle. Some compounded preparations, like the formulations included in this article, can be administered by jet injection, a practice that we suggest will increase in popularity as more drugs are prescribed for administration in the home setting. Because changes in drug concentration may be required to effect the transfer of an agent or ensure the accurate reconstitution of a lyophilized drug administered with a jet injector, the skill of a compounding pharmacist will be essential in preparing customized injectates. In this article, we address the use of needle-free technology in general; present examples of carbon-dioxide, spring-powered, and novel jet injection systems; and answer questions

  19. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Needle-use declarations at the Olympic Games Rio 2016.

    Science.gov (United States)

    Allen, Molly; Stuart, Mark Campbell; Gribble, Hannah; Budgett, Richard; Pipe, Andrew

    2017-11-21

    We report on the results of the 'IOC Needle Policy' applied during the course of the Games of the XXXI Summer Olympiad in Rio de Janeiro, Brazil. The policy was intended to empower physicians to ensure appropriate clinical use of needles within team medical environments, enhance the safety of those responsible for housekeeping services and others in the Olympic environment, and permit documentation of such procedures as an adjunct to the doping control programme. Any needle use required the submission of an 'Injection Declaration Form' to IOC medical officials. All ' Injection Declaration Forms' were reviewed and archived. The declarations provided basic information regarding the nature of the needle use and the product(s) involved, the physician, athlete and respective National Olympic Committee (NOC). The details of the declarations were subsequently categorised. A total of 367 declarations were received from physicians representing 49 NOCs. Needle-use declarations were more common in athletics, gymnastics, football and aquatics. A single product was administered in 60% of the cases, and more than one product was administered in 40%. The majority of declarations indicated the use of local anaesthetics, glucocorticoids, non-steroidal anti-inflammatory drugs and analgesics. The introduction of a 'Needle Policy' in the Olympic Games setting was intended to minimise the use of needles by non-physicians, promote evidence-based practice and to deter needle-based doping practices. Declarations were received from 49 of 209 NOCs suggesting either that needle use is minimal among certain teams or opportunities remain to enhance compliance with such policies at future games. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Safe disposal of surplus plutonium

    Science.gov (United States)

    Gong, W. L.; Naz, S.; Lutze, W.; Busch, R.; Prinja, A.; Stoll, W.

    2001-06-01

    About 150 tons of weapons grade and weapons usable plutonium (metal, oxide, and in residues) have been declared surplus in the USA and Russia. Both countries plan to convert the metal and oxide into mixed oxide fuel for nuclear power reactors. Russia has not yet decided what to do with the residues. The US will convert residues into a ceramic, which will then be over-poured with highly radioactive borosilicate glass. The radioactive glass is meant to provide a deterrent to recovery of plutonium, as required by a US standard. Here we show a waste form for plutonium residues, zirconia/boron carbide (ZrO 2/B 4C), with an unprecedented combination of properties: a single, radiation-resistant, and chemically durable phase contains the residues; billion-year-old natural analogs are available; and criticality safety is given under all conceivable disposal conditions. ZrO 2/B 4C can be disposed of directly, without further processing, making it attractive to all countries facing the task of plutonium disposal. The US standard for protection against recovery can be met by disposal of the waste form together with used reactor fuel.

  2. Final disposal of nuclear waste

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-10-01

    The nuclear industry argues that high level radioactive waste can be safely disposed of in deep underground repositories. As yet, however, no such repositories are in use and the amount of spent nuclear fuel in ponds and dry storage is steadily increasing. Although the nuclear industry further argues that storage is a safe option for up to 50 years and has the merit of allowing the radioactivity of the fuel to decay to a more manageable level, the situation seems to be far from ideal. The real reasons for procrastination over deep disposal seem to have as much to do with politics as safe technology. The progress of different countries in finding a solution to the final disposal of high level waste is examined. In some, notably the countries of the former Soviet Union, cost is a barrier; in others, the problem has not yet been faced. In these countries undertaking serious research into deep disposal there has been a tendency, in the face of opposition from environmental groups, to retreat to sites close to existing nuclear installations and to set up rock laboratories to characterize them. These sites are not necessarily the best geologically, but the laboratories may end up being converted into actual repositories because of the considerable financial investment they represent. (UK).

  3. Final disposal of nuclear waste

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The nuclear industry argues that high level radioactive waste can be safely disposed of in deep underground repositories. As yet, however, no such repositories are in use and the amount of spent nuclear fuel in ponds and dry storage is steadily increasing. Although the nuclear industry further argues that storage is a safe option for up to 50 years and has the merit of allowing the radioactivity of the fuel to decay to a more manageable level, the situation seems to be far from ideal. The real reasons for procrastination over deep disposal seem to have as much to do with politics as safe technology. The progress of different countries in finding a solution to the final disposal of high level waste is examined. In some, notably the countries of the former Soviet Union, cost is a barrier; in others, the problem has not yet been faced. In these countries undertaking serious research into deep disposal there has been a tendency, in the face of opposition from environmental groups, to retreat to sites close to existing nuclear installations and to set up rock laboratories to characterize them. These sites are not necessarily the best geologically, but the laboratories may end up being converted into actual repositories because of the considerable financial investment they represent. (UK)

  4. General Instructions for Disposable Respirators

    Centers for Disease Control (CDC) Podcasts

    2009-04-09

    This podcast, intended for the general public, demonstrates how to put on and take off disposable respirators that are to be used in areas affected by the influenza outbreak.  Created: 4/9/2009 by CDC, National Institute for Occupational Safety and Health (NIOSH).   Date Released: 4/29/2009.

  5. Ocean Disposal of Dredged Material

    Science.gov (United States)

    Permits and authorizations for the ocean dumping of dredged material is issued by U.S. Army Corps of Engineers. Information is provided about where to dispose dredged material and the process for obtaining an ocean dumping permit for dredged material.

  6. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  7. Why should we use atraumatic needles in lumbar puncture?

    Directory of Open Access Journals (Sweden)

    Sandro Luiz de Andrade Matas

    2013-09-01

    Full Text Available Diagnostic lumbar puncture is essential to the diagnosis of central nervous system infections, subarachnoid haemorrhage and others neurological diseases. Myeloradicular involvement or life-threatening adverse events due to the procedure are rare, but less severe complications are more frequent. Post-lumbar puncture headache is the most common complication, by spinal fluid leakage due to delayed closure of a dural defect. Therefore, the development of fine needles, with differentiated atraumatic bevel, has contributed to minimize that problem. These generically called atraumatic needles cause less deformation of the dura mater then the Quincke® ones. So, why don't we use these atraumatic needles?

  8. Low level radioactive waste disposal

    International Nuclear Information System (INIS)

    Balaz, J.; Chren, O.

    2015-01-01

    The Mochovce National Radwaste Repository is a near surface multi-barrier disposal facility for disposal of processed low and very low level radioactive wastes (radwastes) resulting from the operation and decommissioning of nuclear facilities situated in the territory of the Slovak Republic and from research institutes, laboratories, hospitals and other institutions (institutional RAW) which are in compliance with the acceptance criteria. The basic safety requirement of the Repository is to avoid a radioactive release to the environment during its operation and institutional inspection. This commitment is covered by the protection barrier system. The method of solution designed and implemented at the Repository construction complies with the latest knowledge and practice of the repository developments all over the world and meets requirements for the safe radwaste disposal with minimum environmental consequences. All wastes are solidified and have to meet the acceptance criteria before disposal into the Repository. They are processed and treated at the Bohunice RAW Treatment Centre and Liquid RAW Final Treatment Facility at Mochovce. The disposal facility for low level radwastes consists of two double-rows of reinforced concrete vaults with total capacity 7 200 fibre reinforced concrete containers (FCCs) with RAW. One double-row contains 40 The operation of the Repository was started in year 2001 and after ten years, in 2011 was conducted the periodic assessment of nuclear safety with positive results. Till the end of year 2014 was disposed to the Repository 11 514 m 3 RAW. The analysis of total RAW production from operation and decommissioning of all nuclear installation in SR, which has been carried out in frame of the BIDSF project C9.1, has showed that the total volume estimation of conditioned waste is 108 thousand m 3 of which 45.5 % are low level waste (LLW) and 54,5 % very low level waste (VLLW). On the base of this fact there is the need to build 7

  9. High Opening Injection Pressure Is Associated With Needle-Nerve and Needle-Fascia Contact During Femoral Nerve Block.

    Science.gov (United States)

    Gadsden, Jeff; Latmore, Malikah; Levine, D Matt; Robinson, Allegra

    2016-01-01

    High opening injection pressures (OIPs) have been shown to predict sustained needle tip contact with the roots of the brachial plexus. Such roots have a uniquely high ratio of fascicular versus connective tissue. It is unknown if this relationship is preserved during multifascicular nerve blockade. We hypothesized that OIP can predict needle-nerve contact during femoral nerve block, as well as detect needle contact with the fascia iliaca. Twenty adults scheduled for femoral block were recruited. Using ultrasound, a 22-gauge needle was sequentially placed in 4 locations: indenting the fascia iliaca, advanced through the fascia iliaca while lateral to the nerve, slightly indenting the femoral nerve, and withdrawn from the nerve 1 mm. At each location, the OIP required to initiate an injection of 1 mL D5W (5% dextrose in water) at 10 mL/min was recorded. Blinded investigators performed evaluations and aborted injections when an OIP of 15 psi was reached. Opening injection pressure was 15 psi or greater for 90% and 100% of cases when the needle indented the femoral nerve and fascia iliaca, respectively. Opening injection pressure was less than 15 psi for all 20 patients when the needle was withdrawn 1 mm from the nerve as well as at the subfascial position (McNemar χ2 P fascia iliaca (100%). Needle tip positions not indenting these structures were associated with OIP of less than 15 psi (100%).

  10. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  11. Administration technique and storage of disposable insulin pens reported by patients with diabetes.

    Science.gov (United States)

    Mitchell, Virginia D; Porter, Kyle; Beatty, Stuart J

    2012-01-01

    The purpose of the study was to evaluate insulin injection technique and storage of insulin pens as reported by patients with diabetes and to compare correct pen use to initial education on injection technique, hemoglobin A1C, duration of insulin therapy, and duration of insulin pen. Cross-sectional questionnaire orally administered to patients at a university-affiliated primary care practice. Subjects were patients with diabetes who were 18 years or older and prescribed a disposable insulin pen for at least 4 weeks. A correct usage score was calculated for each patient based on manufacturer recommendations for disposable insulin pen use. Associations were made between the correct usage score and certainty in technique, initial education, years of insulin therapy, duration of pen use, and hemoglobin A1C. Sixty-seven patients completed the questionnaire, reporting total use of 94 insulin pens. The 3 components most often neglected by patients were priming pen needle, holding for specific count time before withdrawal of pen needle from skin, and storing an in-use pen. For three-fourths of the insulin pens being used, users did not follow the manufacturer's instructions for proper administration and storage of insulin pens. Correct usage scores were significantly higher if initial education on insulin pens was performed by a pharmacist or nurse. The majority of patients may be ignoring or unaware of key components for consistent insulin dosing using disposable insulin pens; therefore, initial education and reeducation on correct use of disposable insulin pens by health care professionals are needed.

  12. Dataset on force measurements of needle insertions into two ex-vivo human livers

    NARCIS (Netherlands)

    de Jong, T.L.; Dankelman, J.; van den Dobbelsteen, J.J.

    2017-01-01

    A needle-tissue interaction experiment has been carried out, by inserting the inner needle of a trocar needle into two ex-vivo human livers. The dataset contains the forces that act on the needle during insertion and retraction into the livers. In addition, a MATLAB code file is included that

  13. Radioactive waste disposal and political aspects

    International Nuclear Information System (INIS)

    Blanc, M.

    1992-01-01

    The difficulties presented by the current atomic energy law for the nuclear waste disposal in Switzerland are shown. It is emphasised how important scientific information is in the political solutions for nuclear disposal

  14. A sewing needle in liver: a case report and review of the literature.

    Science.gov (United States)

    Feng, Quan Zhou; Wang, Jie; Sun, Hong

    2009-06-01

    Hepatic foreign bodies are quite rare. A sewing needle as a hepatic foreign body in an old woman is very rare and the managements have been varied. An old woman was incidentally found to have a sewing needle in her liver on abdominal X-ray. The sewing needle was kept stable in her liver after two years of follow-up. Eleven cases of sewing needle in the liver were reviewed. Sewing needle as a foreign body in the liver is rare. In general, the sewing needle should be removed through laparotomy or laparoscopy, but a stable and uncomplicated sewing needle in the liver need not be removed.

  15. Metallic sewing needle ingestion presenting as acute abdomen.

    Science.gov (United States)

    Misra, S; Jain, V; Ahmad, F; Kumar, R; Kishore, N

    2013-01-01

    We reported an unusual case of a 26-year-old man presenting to surgical emergency as generalized peritonitis following an ingestion of multiple metallic sewing needles. The X-ray of his abdomen showed pneumoperitoneum and multiple metallic foreign bodies in the abdominal cavity. An ultrasonogram of his abdomen showed multiple metallic foreign bodies in the abdominal cavity and urinary bladder. Emergency exploratory laparotomy was performed. On laparotomy, gastric and duodenal perforation was found through which metallic sewing needles were protruding out. A peritoneal lavage was done, and all the sewing needles were extracted from the perforation site, paracolic gutter, liver parenchyma, and urinary bladder. The primary repair of the perforation with omental patching was done with the drainage of subhepatic space and pelvic cavity. These multiple ingested sewing needles led to the perforation of the stomach and the duodenum, which resulted in perforation peritonitis.

  16. Video endoscopy: removal of retained sewing needles from the duodenum.

    Science.gov (United States)

    Gajbhiye, Ashok S; Gajbhiye, Raj N; Tirupude, Bhupesh H; Bajaj, Prasang P; Gupta, Tarush H

    2013-06-01

    We report an interesting case of a 21-year-old unmarried girl who swallowed six sewing needles. Her complaints were pain in the epigastrium, associated with nausea and vomiting. On examination, there was mild tenderness in the epigastrium. X-ray of the abdomen and endoscopy confirmed the presence of six needles in the duodenum, with tips lodged in the duodenal wall. Psychiatric opinion was sought which was normal. Under video endoscope (Pentax 2.8, EG 27708) guidance with Captura biopsy forceps without spikes (Cook DBF-2.4-160-S), six sewing needles were removed successfully from the duodenum through the endoscope channel without any complications. However, a video endoscopic removal of the retained six needles from duodenum is probably being reported for the first time.

  17. [Doctor HUANG Shi-ping's acupuncture with golden needles].

    Science.gov (United States)

    Chen, Teng-Fei; Ma, Zeng-Bin; Xin, Si-Yuan; Zhu, Jiang

    2013-08-01

    Taking Doctor HUANG Shi-ping as the representative, the school of Huang's golden needle is based on Chinese martial art. Golden needles are adopted as main tool. Attaching great importance on the combination of acupuncture and moxibustioin, it is also characterized with penetrating needling with long needles. Through the development of three generations, it once outshone other schools in the field of acupuncture, and became famous all over the world. It made great contribution to the development of the course of acupuncture. However, with the development of the history, the form of acupuncture education as well as apparatus were all undergone an unified reform. Therefore, Doctor HUANG Shi-ping's acupuncture school be lost gradually.

  18. NEEDLE ANATOMY CHANGES WITH INCREASING TREE AGE IN DOUGLAS FIR

    Science.gov (United States)

    Morphological differences between old growth and sapling (Pseudotsuga menziesii, (Mirb.) Franco) Douglas fir trees may extend to differences in needle anatomy. We used microscopy with image analysis to compare and quantify anatomical parameters in cross-sections of previous year...

  19. Needle phobia--changing venepuncture practice in ambulatory care.

    Science.gov (United States)

    Thurgate, Claire; Heppell, Sue

    2005-11-01

    Needle phobia is a term used in practice to describe an anticipatory fear of needle insertion. A proportion of children display high levels of fear, pain and behavioural distress when exposed to, or anticipating, needle insertion. A difficult routine venepuncture in our ambulatory care unit led staff to review practice and develop a three-step approach to overcoming 'needle phobia': relaxation, control and graded exposure. These developments have resulted in the unit becoming a local referral centre for children and young people between the ages of 5-19 years with this problem. Time and skill are needed to prevent or overcome this distressing problem which can be caused by health care professionals not listening to children and young people.

  20. A Multicenter comparative trial of a novel EUS-guided core biopsy needle (SharkCore™) with the 22-gauge needle in patients with solid pancreatic mass lesions.

    Science.gov (United States)

    Naveed, Mariam; Siddiqui, Ali A; Kowalski, Thomas E; Loren, David E; Khalid, Ammara; Soomro, Ayesha; Mazhar, Syed M; Yoo, Joseph; Hasan, Raza; Yalamanchili, Silpa; Tarangelo, Nicholas; Taylor, Linda J; Adler, Douglas G

    2018-01-01

    The ability to obtain adequate tissue of solid pancreatic lesions by EUS-guided remains a challenge. The aim of this study was to compare the performance characteristics and safety of EUS-FNA for evaluating solid pancreatic lesions using the standard 22-gauge needle versus a novel EUS biopsy needle. This was a multicenter retrospective study of EUS-guided sampling of solid pancreatic lesions between 2009 and 2015. Patients underwent EUS-guided sampling with a 22-gauge SharkCore (SC) needle or a standard 22-gauge FNA needle. Technical success, performance characteristics of EUS-FNA, the number of needle passes required to obtain a diagnosis, diagnostic accuracy, and complications were compared. A total of 1088 patients (mean age = 66 years; 49% female) with pancreatic masses underwent EUS-guided sampling with a 22-gauge SC needle (n = 115) or a standard 22-gauge FNA needle (n = 973). Technical success was 100%. The frequency of obtaining an adequate cytology by EUS-FNA was similar when using the SC and the standard needle (94.1% vs. 92.7%, respectively). The sensitivity, specificity, and diagnostic accuracy of EUS-FNA for tissue diagnosis were not significantly different between two needles. Adequate sample collection leading to a definite diagnosis was achieved by the 1 st , 2 nd , and 3 rd pass in 73%, 92%, and 98% of procedures using the SC needle and 20%, 37%, and 94% procedures using the standard needle (P < 0.001), respectively. The median number of passes to obtain a tissue diagnosis using the SC needle was significantly less as compared to the standard needle (1 and 3, respectively; P< 0.001). The EUS SC biopsy needle is safe and technically feasible for EUS-FNA of solid pancreatic mass lesions. Preliminary results suggest that the SC needle has a diagnostic yield similar to the standard EUS needle and significantly reduces the number of needle passes required to obtain a tissue diagnosis.

  1. Disposable products in the hospital waste stream.

    OpenAIRE

    Gilden, D. J.; Scissors, K. N.; Reuler, J. B.

    1992-01-01

    Use of disposable products in hospitals continues to increase despite limited landfill space and dwindling natural resources. We analyzed the use and disposal patterns of disposable hospital products to identify means of reducing noninfectious, nonhazardous hospital waste. In a 385-bed private teaching hospital, the 20 disposable products of which the greatest amounts (by weight) were purchased, were identified, and total hospital waste was tabulated. Samples of trash from three areas were so...

  2. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  3. Cardiac tamponade caused by a migrating sewing needle.

    Science.gov (United States)

    Affronti, Alessandro; Di Bella, Isidoro; Di Lazzaro, Davide; Capozzi, Rosanna; Scarnecchia, Elisa; Ragni, Temistocle

    2016-12-01

    : Penetrating injuries of the heart caused by migrating needles have been rarely described. They usually occur accidentally or are self-inflicted in the setting of an underlying psychiatric disorder. We present an unusual case of cardiac tamponade caused by a sewing needle that migrated to the heart from the chest wall through the lung. The lesions were successfully repaired through a median sternotomy without cardiopulmonary bypass. The pathophysiological mechanism and the pertinent literature are briefly analysed.

  4. Enterobacter aerogenes Needle Stick Leads to Improved Biological Management System

    Energy Technology Data Exchange (ETDEWEB)

    Johanson, Richard E.

    2004-08-01

    A laboratory worker who received a needle stick from a contaminated needle while working with a culture containing Enterobactor aerogenes developed a laboratory acquired infection. Although this organism has been shown to cause community and nosocomial infections, there have been no documented cases of a laboratory acquired infections. Lessons learned from the event led to corrective actions which included modification of lab procedures, development of a biological inventory tracking and risk identification system and the establishment of an effective biological safety program.

  5. Percutaneous needle cricothyroidotomy with repetitive airway obstruction.

    Science.gov (United States)

    Hauswald, M; Ong, G; Yeoh, E

    1995-11-01

    To develop a technique for needle cricothyrotomy that mimics the normal respiratory cycle (using repetitive obstruction of the upper airway and relatively low flow oxygen through small catheters), a controlled trial in three anesthetized dogs was performed. Oxygen from a standard bottle and pressure reducer was delivered through the cricothyroid membrane at 0.36 L/kg/min, which is metabolically equivalent to 0.2 L/kg/min in an adult human. The upper airway was obstructed until the chest rose and then was unobstructed to allow exhalation. The animals were ventilated for 5 minutes to allow equilibration. Arterial PCO2 was measured after 2-minute periods of apnea and 3 minutes of ventilation, each repeated four times. The procedure was repeated in three other dogs at a flow of 0.18 L/kg/min to simulate a 50% air leak. Cricothyroid ventilation at 0.36 L/kg/min lowered the PCO2 from 65 mm Hg to 43 mm Hg, F = 258, P = .004. All PCO2 after 25 minutes were in the normal range. Ventilation at 0.18 L/kg/min stabilized the PCO2 at approximately 1.5 times normal (67 mm Hg versus 79 mm Hg for the preceding apnea, F = 77, P = .013). Flow rates achievable with 18- to 20-gauge catheters and standard oxygen sources are adequate for cricothyroid ventilation when the airway is repetitively obstructed to allow a normal respiratory cycle.

  6. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  7. Susuks (charm needles) in the craniofacial region

    International Nuclear Information System (INIS)

    Nambiar, P.; Ibrahim, N.; Tandjung, Y.R.M.; Shanmuhasuntharam, P.

    2008-01-01

    We conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI). We studied various radiographs of 33 susuk wearers (age range, 33-69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine's magnet. The largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics. As susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI. (author)

  8. Micro-needle electro-tactile display.

    Science.gov (United States)

    Tezuka, Mayuko; Kitamura, Norihide; Miki, Norihisa

    2015-08-01

    Haptic feedback is strongly demanded for high-precision robot-assisted surgery and teleoperation. The haptic feedback consists of force and tactile feedback, however tactile feedback has been little studied and the size and weight of the system poses challenges for practical applications. In this paper we propose a sheet-type wearable electro-tactile display which provides tactile sensations to the user as the feedback at a low voltage and power consumption. The display possesses needle-shaped electrodes, which can penetrate through the high-impedance stratum corneum. We developed the fabrication process and, as the first step, we investigated the tactile sensation that can be created to the fingertip by the display. Rough and smooth surfaces were successfully presented to the user. Then, we characterized the tactile display when used on the forearm, in particular, with respect to the spatial resolution. These tactile displays can be used to inform the user of the surface property of the parts of interest, such as tumor tissues, and to guide him in the manipulation of surgery robots.

  9. Concept for Underground Disposal of Nuclear Waste

    Science.gov (United States)

    Bowyer, J. M.

    1987-01-01

    Packaged waste placed in empty oil-shale mines. Concept for disposal of nuclear waste economically synergistic with earlier proposal concerning backfilling of oil-shale mines. New disposal concept superior to earlier schemes for disposal in hard-rock and salt mines because less uncertainty about ability of oil-shale mine to contain waste safely for millenium.

  10. 40 CFR 761.60 - Disposal requirements.

    Science.gov (United States)

    2010-07-01

    ... a TSCA-approved disposal facility, as bulk product waste under § 761.62, as household waste under... incinerator that complies with § 761.70; or (B) Until March 1, 1981, disposal in a chemical waste landfill... which complies with § 761.70; or (B) Until March 1, 1981, disposal in a chemical waste landfill which...

  11. Solid waste disposal into salt mines

    International Nuclear Information System (INIS)

    Repke, W.

    1981-01-01

    The subject is discussed as follows: general introduction to disposal of radioactive waste; handling of solid nuclear waste; technology of final disposal, with specific reference to salt domes; conditioning of radioactive waste; safety barriers for radioactive waste; practice of final disposal in other countries. (U.K.)

  12. Needle and syringe sharing among Iranian drug injectors

    Directory of Open Access Journals (Sweden)

    Roshanpajouh Mohsen

    2009-07-01

    Full Text Available Abstract Objective The role of needle and syringe sharing behavior of injection drug users (IDUs in spreading of blood-borne infections – specially HIV/AIDS – is well known. However, very little is known in this regard from Iran. The aim of our study was to determine the prevalence and associates of needle and syringe sharing among Iranian IDUs. Methods In a secondary analysis of a sample of drug dependents who were sampled from medical centers, prisons and streets of the capitals of 29 provinces in the Iran in 2007, 2091 male IDUs entered. Socio-demographic data, drug use data and high risk behaviors entered to a logistic regression to determine independent predictors of lifetime needle and syringe sharing. Results 749(35.8% reported lifetime experience of needle and syringe sharing. The likelihood of lifetime needle and syringe sharing was increased by female gender, being jobless, having illegal income, drug use by family members, pleasure/enjoyment as causes of first injection, first injection in roofless and roofed public places, usual injection at groin, usual injection at scrotum, lifetime experience of nonfatal overdose, and history of arrest in past year and was decreased by being alone at most injections. Conclusion However this data has been extracted from cross-sectional design and we can not conclude causation, some of the introduced variables with association with needle and syringe sharing may be used in HIV prevention programs which target reducing syringe sharing among IDUs.

  13. Neuromuscular Damage and Repair after Dry Needling in Mice

    Directory of Open Access Journals (Sweden)

    Ares Domingo

    2013-01-01

    Full Text Available Objective. Some dry needling treatments involve repetitive and rapid needle insertions into myofascial trigger points. This type of treatment causes muscle injury and can also damage nerve fibers. The aim of this study is to determine the injury caused by 15 repetitive punctures in the muscle and the intramuscular nerves in healthy mouse muscle and its ulterior regeneration. Methods. We repeatedly needled the levator auris longus muscle of mice, and then the muscles were processed with immunohistochemistry, methylene blue, and electron microscopy techniques. Results. Three hours after the dry needling procedure, the muscle fibers showed some signs of an inflammatory response, which progressed to greater intensity 24 hours after the procedure. Some inflammatory cells could still be seen when the muscle regeneration was almost complete seven days after the treatment. One day after the treatment, some changes in the distribution of receptors could be observed in the denervated postsynaptic component. Reinnervation was complete by the third day after the dry needling procedure. We also saw very fine axonal branches reinnervating all the postsynaptic components and some residual sprouts the same day. Conclusion. Repeated dry needling punctures in muscle do not perturb the different stages of muscle regeneration and reinnervation.

  14. A portable integrated system to control an active needle

    Science.gov (United States)

    Konh, Bardia; Motalleb, Mahdi; Ashrafiuon, Hashem

    2017-04-01

    The primary objective of this work is to introduce an integrated portable system to operate a flexible active surgical needle with actuation capabilities. The smart needle uses the robust actuation capabilities of the shape memory alloy wires to drastically improve the accuracy of in medical procedures such as brachytherapy. This, however, requires an integrated system aimed to control the insertion of the needle via a linear motor and its deflection by the SMA wire in real-time. The integrated system includes a flexible needle prototype, a Raspberry Pi computer, a linear stage motor, an SMA wire actuator, a power supply, electromagnetic tracking system, and various communication supplies. The linear stage motor guides the needle into tissue. The power supply provides appropriate current to the SMA actuator. The tracking system measures tip movement for feedback, The Raspberry Pi is the central tool that receives the tip movement feedback and controls the linear stage motor and the SMA actuator via the power supply. The implemented algorithms required for communication and feedback control are also described. This paper demonstrates that the portable integrated system may be a viable solution for more effective procedures requiring surgical needles.

  15. Novel design of honeybee-inspired needles for percutaneous procedure.

    Science.gov (United States)

    Sahlabadi, Mohammad; Hutapea, Parsaoran

    2018-04-18

    The focus of this paper is to present new designs of innovative bioinspired needles to be used during percutaneous procedures. Insect stingers have been known to easily penetrate soft tissues. Bioinspired needles mimicking the barbs in a honeybee stinger were developed for a smaller insertion force, which can provide a less invasive procedure. Decreasing the insertion force will decrease the tissue deformation, which is essential for more accurate targeting. In this study, some design parameters, in particular, barb shape and geometry (i.e. front angle, back angle, and height) were defined, and their effects on the insertion force were investigated. Three-dimensional printing technology was used to manufacture bioinspired needles. A specially-designed insertion test setup using tissue mimicking polyvinyl chloride (PVC) gels was developed to measure the insertion and extraction forces. The barb design parameters were then experimentally modified through detailed experimental procedures to further reduce the insertion force. Different scales of the barbed needles were designed and used to explore the size-scale effect on the insertion force. To further investigate the efficacy of the proposed needle design in real surgeries, preliminary ex vivo insertion tests into bovine liver tissue were performed. Our results show that the insertion force of the needles in different scales decreased by 21-35% in PVC gel insertion tests, and by 46% in bovine liver tissue insertion tests.

  16. Nursing and safety of silver needle diathermy treating ankylosing spondylitis.

    Science.gov (United States)

    Ning, Huaxiu; Wang, Yun; Yuan, Yiwen; Ning, Huaying

    2015-03-01

    This paper aims to discuss the nursing and safety of silver needle diathermy in the treatment for ankylosing spondylitis. We nursed 46 patients with ankylosing spondylitis treated with silver needle diathermy. Specific nursing was focused on physical condition evaluation and mental nursing before treatment, observation during and after treatment, diet nursing, needle eye nursing, functional training and propaganda and education when discharged. The result suggested that all the patients received mental nursing, diet guide, skin care, health education, functional training and follow-up visit from the nurse and all of them could endure silver needle diathermy as discomfort or drug allergy was barely found, so were slight scald and skin infection nearby the needle eye caused by fainting during acupuncture, accidental puncture or overheat. Follow-up visit showed that no patient suffered obvious untoward effect and the pain, joint range of motion and living condition were distinctly improved a week after discharging. In conclusion, during the treatment for ankylosing spondylitis applying silver needle diathermy, the nursing before, during and after the treatment can obviously reduce the complication, accelerate the recovery, which is highly safe.

  17. Dry needling in lateral epicondylitis: a prospective controlled study.

    Science.gov (United States)

    Uygur, Esat; Aktaş, Birol; Özkut, Afşar; Erinç, Samet; Yilmazoglu, Emime Gül

    2017-11-01

    Lateral epicondylitis (LE), a common disease, especially in middle age, causes decreased productivity and economic losses. The first-line treatment for LE is conservative and consists of topical and oral anti-inflammatory drugs, ice application, and brace use. If the first-line treatment fails, second-line treatment modalities, which are generally invasive, are offered. Second-line therapeutic regimens include saline, corticosteroid, or platelet-rich plasma injections. Dry needling is relatively new. We hypothesized that dry needling would be at least as effective as first-line treatment for LE. We compared the outcomes of first-line treatment and dry needling. The study allocated 110 patients into groups using online randomization software. After completing the Patient-rated Tennis Elbow Evaluation (PRTEE), patients in group I received dry needling, whereas those in group II received first-line treatment, consisting of ibuprofen 100 mg twice a day and a proximal forearm brace. The patients were evaluated after three weeks and six months. The study ultimately analyzed 92 patients. Although both treatment methods were effective at three weeks, dry needling was significantly more effective than the first-line treatment at six months. Because of the low complication rate, dry needling is a safe method, and it might be an effective treatment option for LE.

  18. Change of needle temperature during one cycle of sewing operation in thermal equilibrium

    OpenAIRE

    川西, 定子; 宮脇, 知子; Sadako, Kawanishi; Tomoko, Miyawaki

    2003-01-01

    The rise and fall during one cycle of sewing operation, in the equilibrium needle temperature was discussed. At a constant sewing velocity, the higher the needle temperature was, the bigger the amount of rise and fall during one cycle in an equilibrium needle temperature was. As the sewing velocity rose, the needle temperature increased, but the amount of rise and fall during one cycle of sewing operation in the equilibrium needle temperature decreased. The reason was that the fall time decre...

  19. Colonization and lignin decomposition of pine needle litter by Lophodermium pinastri

    OpenAIRE

    Osono, T.; Hirose, D.

    2010-01-01

    The colonization and lignin decomposition of pine (Pinus thunbergii and Pinus densiflora) needle litter by an endophytic fungus, Lophodermium pinastri, was examined with field observations, a field experiment and laboratory experiments. In pine needles collected from the field, needle mass per length and lignin content were lower in needle portions bearing Lophodermium fruiting bodies than in the remaining needle portions, whereas total carbohydrate content was not different between them. Tot...

  20. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  1. Final disposal of radioactive waste

    Directory of Open Access Journals (Sweden)

    Freiesleben H.

    2013-06-01

    Full Text Available In this paper the origin and properties of radioactive waste as well as its classification scheme (low-level waste – LLW, intermediate-level waste – ILW, high-level waste – HLW are presented. The various options for conditioning of waste of different levels of radioactivity are reviewed. The composition, radiotoxicity and reprocessing of spent fuel and their effect on storage and options for final disposal are discussed. The current situation of final waste disposal in a selected number of countries is mentioned. Also, the role of the International Atomic Energy Agency with regard to the development and monitoring of international safety standards for both spent nuclear fuel and radioactive waste management is described.

  2. Siting of geological disposal facilities

    International Nuclear Information System (INIS)

    1994-01-01

    Radioactive waste is generated from the production of nuclear energy and from the use of radioactive materials in industrial applications, research and medicine. The importance of safe management of radioactive waste for the protection of human health and the environment has long been recognized and considerable experience has been gained in this field. The Radioactive Waste Safety Standards (RADWASS) programme is the IAEA's contribution to establishing and promoting the basic safety philosophy for radioactive waste management and the steps necessary to ensure its implementation. This Safety Guide defines the process to be used and guidelines to be considered in selecting sites for deep geological disposal of radioactive wastes. It reflects the collective experience of eleven Member States having programmes to dispose of spent fuel, high level and long lived radioactive waste. In addition to the technical factors important to site performance, the Safety Guide also addresses the social, economic and environmental factors to be considered in site selection. 3 refs

  3. Effluent treatment and waste disposal

    International Nuclear Information System (INIS)

    1990-01-01

    In recent years there has been a great increase in the attention given to environmental matters by the public, media and Government. This has been reflected in the increased stature of environmental pressure groups and the introduction of new regulatory bodies and procedures. However, the satisfactory treatment and disposal of waste depends ultimately upon the development and employment of efficient low cost processes, and the enforcement of effective legislation. This Conference organised by the Yorkshire Branch of IChemE in association with the Institution's Environmental Protection Subject Group, will address the areas of waste monitoring, developments in pollution control processes and process economics and will look forward to future trends in waste disposal. It will also consider the impact of recent legislation upon the process industries. (author)

  4. Shallow disposal of radioactive waste

    International Nuclear Information System (INIS)

    1985-02-01

    A review and evaluation of computer codes capable of simulating the various processes that are instrumental in determining the dose rate to individuals resulting from the shallow disposal of radioactive waste was conducted. Possible pathways of contamination, as well as the mechanisms controlling radionuclide movement along these pathways have been identified. Potential transport pathways include the unsaturated and saturated ground water systems, surface water bodies, atmospheric transport and movement (and accumulation) in the food chain. Contributions to dose may occur as a result of ingestion of contaminated water and food, inhalation of contaminated air and immersion in contaminated air/water. Specific recommendations were developed regarding the selection and modification of a model to meet the needs associated with the prediction of dose rates to individuals as a consequence of shallow radioactive waste disposal. Specific technical requirements with regards to risk, sensitivity and uncertainty analyses have been addressed

  5. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver

    Directory of Open Access Journals (Sweden)

    Arvind P Ganpule

    2018-01-01

    Conclusion: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  6. Nuclear waste management and disposal

    International Nuclear Information System (INIS)

    Czibolya, L.

    1983-01-01

    The general demands for radioactive waste management, the key problem of nuclear fuel cycle are discussed. Various processes have been developed to solidify highly radioactive, long-lived wastes of the reprocessing plants in the form of borosilicate or phosphate glasses. Wastes of medium and low activity are generally solidified using either cement or bitumen or polyethylene as matrices. The alternatives of final waste disposal are reviewed according to French, Soviet, American, British, Swedish, Indian and Japanese experiences. (V.N.)

  7. Disposal of spent nuclear fuel

    International Nuclear Information System (INIS)

    1979-12-01

    This report addresses the topic of the mined geologic disposal of spent nuclear fuel from Pressurized Water Reactors (PWR) and Boiling Water Reactors (BWR). Although some fuel processing options are identified, most of the information in this report relates to the isolation of spent fuel in the form it is removed from the reactor. The characteristics of the waste management system and research which relate to spent fuel isolation are discussed. The differences between spent fuel and processed HLW which impact the waste isolation system are defined and evaluated for the nature and extent of that impact. What is known and what needs to be determined about spent fuel as a waste form to design a viable waste isolation system is presented. Other waste forms and programs such as geologic exploration, site characterization and licensing which are generic to all waste forms are also discussed. R and D is being carried out to establish the technical information to develop the methods used for disposal of spent fuel. All evidence to date indicates that there is no reason, based on safety considerations, that spent fuel should not be disposed of as a waste

  8. Disposal of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report addresses the topic of the mined geologic disposal of spent nuclear fuel from Pressurized Water Reactors (PWR) and Boiling Water Reactors (BWR). Although some fuel processing options are identified, most of the information in this report relates to the isolation of spent fuel in the form it is removed from the reactor. The characteristics of the waste management system and research which relate to spent fuel isolation are discussed. The differences between spent fuel and processed HLW which impact the waste isolation system are defined and evaluated for the nature and extent of that impact. What is known and what needs to be determined about spent fuel as a waste form to design a viable waste isolation system is presented. Other waste forms and programs such as geologic exploration, site characterization and licensing which are generic to all waste forms are also discussed. R and D is being carried out to establish the technical information to develop the methods used for disposal of spent fuel. All evidence to date indicates that there is no reason, based on safety considerations, that spent fuel should not be disposed of as a waste.

  9. Pathology Reporting of Thyroid Core Needle Biopsy: A Proposal of the Korean Endocrine Pathology Thyroid Core Needle Biopsy Study Group

    OpenAIRE

    Jung, Chan Kwon; Min, Hye Sook; Park, Hyo Jin; Song, Dong Eun; Kim, Jang Hee; Park, So Yeon; Yoo, Hyunju; Shin, Mi Kyung

    2015-01-01

    In recent years throughout Korea, the use of ultrasound-guided core needle biopsy (CNB) has become common for the preoperative diagnosis of thyroid nodules. However, there is no consensus on the pathology reporting system for thyroid CNB. The Korean Endocrine Pathology Thyroid Core Needle Biopsy Study Group held a conference on thyroid CNB pathology and developed guidelines through contributions from the participants. This article discusses the outcome of the discussions that led to a consens...

  10. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis

    Science.gov (United States)

    Stasi, Elisa; Di Maso, Marianna; Serviddio, Gaetano; Ali Hussein, Mohammed Salah; Muscatiello, Nicola

    2016-01-01

    Background Robust data in favour of a clear superiority of 22 versus 25 Gauge needles for endoscopic ultrasound-guided fine needle aspiration are still lacking. Objective We aimed to compare the diagnostic sensitivity, specificity and safety of these two needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions. Methods A computerized bibliographic search was restricted to randomized controlled trials only. Pooled effects were calculated using a random-effects model and expressed in terms of risk ratio and 95% confidence interval. Results We analysed seven trials with 689 patients and 732 lesions (295 sampled with 22 Gauge needle, 309 with 25 Gauge needle, and 128 with both needles). A non-significant superiority of 25 Gauge in terms of pooled sensitivity (risk ratio: 0.93, 0.91–0.95 versus 0.89, 0.85–0.94 of 22 Gauge needle; p = 0.13) and no difference in terms of specificity (1.00, 0.98–1.00 in both groups; p = 0.85) were observed. Sample adequacy was similar between the two devices (risk ratio: 1.03, 0.99–1.06; p = 0.15). Very few adverse events were observed and did not impact on patient outcomes. Conclusion Our meta-analysis reveals non-superiority of 25 Gauge over 22 Gauge; hence no definitive recommendations over the use of one particular device can be made. PMID:29026598

  11. Social dimensions of nuclear waste disposal

    International Nuclear Information System (INIS)

    Grunwald, Armin

    2015-01-01

    Nuclear waste disposal is a two-faceted challenge: a scientific and technological endeavour, on the one hand, and confronted with social dimensions, on the other. In this paper I will sketch the respective social dimensions and will give a plea for interdisciplinary research approaches. Relevant social dimensions of nuclear waste disposal are concerning safety standards, the disposal 'philosophy', the process of determining the disposal site, and the operation of a waste disposal facility. Overall, cross-cutting issues of justice, responsibility, and fairness are of major importance in all of these fields.

  12. Social dimensions of nuclear waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, Armin [Karlsruhe Institute of Technology, Karlsruhe (Germany). Inst. for Technology Assessment and Systems Analysis

    2015-07-01

    Nuclear waste disposal is a two-faceted challenge: a scientific and technological endeavour, on the one hand, and confronted with social dimensions, on the other. In this paper I will sketch the respective social dimensions and will give a plea for interdisciplinary research approaches. Relevant social dimensions of nuclear waste disposal are concerning safety standards, the disposal 'philosophy', the process of determining the disposal site, and the operation of a waste disposal facility. Overall, cross-cutting issues of justice, responsibility, and fairness are of major importance in all of these fields.

  13. Geomechanical problems in study of radioactive wastes disposal

    International Nuclear Information System (INIS)

    Feng Yixing

    1987-01-01

    Methods for both low-intermediate level radioactive wastes disposal and high level radioactive waste disposal were introduced briefly. Geomechanical problems in radioactive wastes disposal were discussed. Some suggestions were proposed for the radioactive wastes disposal in China

  14. Prevalence of Taura syndrome virus (TSV and Infectious hypodermal and haematopoietic necrosis virus (IHHNV in white shrimp (Penaeus vannamei populations and susceptibility to infection of some aquatic species native to Thailand

    Directory of Open Access Journals (Sweden)

    Supamattaya, K.

    2005-02-01

    Full Text Available This study aimed to survey the prevalence of some infectious diseases e.g. Taura syndrome virus (TSV and Infectious hypodermal and haematopoietic necrosis virus (IHHNV in white shrimp (Penaeus vannamei populations and to assess the impact of such infectious agents to indigenous aquatic animals in Thailand. Samples of both larval and juvenile or adult shrimp from each region of the country were collected and screened for TSV and IHHNV using the polymerase chain reaction (PCR technique. Viruses isolated from affected shrimp were used for determine the susceptibility to infection of some aquatic species native to Thailand.A total of 163 samples of larval shrimp from hatcheries were screened. The results showed infection with TSV and IHHNV in 3.68 and 44.17%, respectively. As high as 7.32% TSV infection was detected in shrimp samples collected from the South Eastern coast, followed by the Eastern and Central regions with percentages of 5.56 and 4.53, respectively. Shrimp with the highest rate of IHHNV infection, 55.56% were collected from the Eastern region. A total of 192 samples of shrimp reared in grow-out ponds were also collected. The results showed shrimp were infected with TSV and IHHNV with percentages of 6.67 and 67.19, respectively. The highest prevalence of IHHNV (up to 90% was found in samples collected from the lower Southern region. The highest prevalence of TSV infection (11.29% was reported in shrimp from the Central region. A study of the susceptibility to TSV and IHHNV infection of some indigenous aquatic species of Thailand was also carried out. The results showed many aquatic species native to Thailand e.g. black tiger shrimp (Penaeus monodon, speckled shrimp (Metapenaeus monoceros, dwarf prawn (Macrobrachium equideus, krill (Acetes sp., mantis lobster (Chloridopsis immaculatus, freshwater prawn (Macrobrachium lanchesteri and M. rosenbergii, mangrove crab (Sesarma sp. and mud crab (Scylla serrata were susceptible to viruses and

  15. Single-Needle Arthrocentesis with Upper Compartment Distension versus Conventional Two-Needle Arthrocentesis: Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Eduardo Grossmann

    2017-01-01

    Full Text Available The objective of this study was to compare single-needle arthrocentesis with distension of the upper compartment of the temporomandibular joint (TMJ with the conventional two-needle arthrocentesis. Twenty-six patients with articular disc displacement without reduction (DDWOR were included in the study and assigned to two groups (n=13: single-needle arthrocentesis with distension of the upper compartment of the TMJ (1N and conventional two-needle arthrocentesis (2N. The maximum interincisal distance (MID and TMJ pain as measured by the visual analog scale (VAS were compared. MID and VAS data were obtained: before (T1, seven days after (T2, fifteen days after (T3, one month after (T4, three months after (T5, six months after (T6, nine months after (T7, and one year after the arthrocentesis procedures (T8. Considering each group individually, results of the VAS scores and MID measurements showed a significant difference between T1 and T2–T8 (p0.05. Both techniques tested were effective in reducing pain and increasing MID. Due to the advantages over the conventional two-needle arthrocentesis, single-needle arthrocentesis with distension of the upper compartment should be considered as the first treatment option for patients with painful hypomobilized TMJ of DDWOR.

  16. Overview of nuclear waste disposal in space

    International Nuclear Information System (INIS)

    Rice, E.E.; Priest, C.C.

    1981-01-01

    One option receiving consideration by the Department of Energy (DOE) is the space disposal of certain high-level nuclear wastes. The National Aeronautics and Space Administration is assessing the space disposal option in support of DOE studies on alternatives for nuclear waste management. The space disposal option is viewed as a complement, since total disposal of fuel rods from commercial power plants is not considered to be economically practical with Space Shuttle technology. The space disposal of certain high-level wastes may, however, provide reduced calculated and perceived risks. The space disposal option in conjunction with terrestrial disposal may offer a more flexible and lower risk overall waste management system. For the space disposal option to be viable, it must be demonstrated that the overall long-term risks associated with this activity, as a complement to the mined geologic repository, would be significantly less than the long-term risk associated with disposing of all the high-level waste. The long-term risk benefit must be achieved within an acceptable short-term and overall program cost. This paper briefly describes space disposal alternatives, the space disposal destination, possible waste mixes and forms, systems and typical operations, and the energy and cost analysis

  17. Development of technical information database for high level waste disposal

    International Nuclear Information System (INIS)

    Kudo, Koji; Takada, Susumu; Kawanishi, Motoi

    2005-01-01

    A concept design of the high level waste disposal information database and the disposal technologies information database are explained. The high level waste disposal information database contains information on technologies, waste, management and rules, R and D, each step of disposal site selection, characteristics of sites, demonstration of disposal technology, design of disposal site, application for disposal permit, construction of disposal site, operation and closing. Construction of the disposal technologies information system and the geological disposal technologies information system is described. The screen image of the geological disposal technologies information system is shown. User is able to search the full text retrieval and attribute retrieval in the image. (S.Y. )

  18. Diversity of endophytic fungi of single Norway spruce needles and their role as pioneer decomposers.

    Science.gov (United States)

    Müller, M M; Valjakka, R; Suokko, A; Hantula, J

    2001-07-01

    The diversity of endophytic fungi within single symptomless Norway spruce needles is described and their possible role as pioneer decomposers after needle detachment is investigated. The majority (90%) of all 182 isolates from green intact needles were identified as Lophodermium piceae. Up to 34 isolates were obtained from single needles. Generally, all isolates within single needles had distinct randomly amplified microsatellite (RAMS) patterns. Single trees may thus contain a higher number of L. piceae individuals than the number of their needles. To investigate the ability of needle endophytes to act as pioneer decomposers, surface-sterilized needles were incubated on sterile sand inoculated with autoclaved or live spruce forest humus layer. The dry weight loss of 13-17% found in needles after a 20-week incubation did not significantly differ between the sterilized and live treatments. Hence, fungi surviving the surface sterilization of needles can act as pioneer decomposers. A considerable portion of the needles remained green during the incubation. Brown and black needles, in which the weight loss had presumably taken place, were invaded throughout by single haplotypes different from L. piceae. Instead, Tiarasporella parca, a less common needle endophyte, occurred among these invaders of brown needles. Needle endophytes of Norway spruce seem thus to have different abilities to decompose host tissues after needle cast. L. piceae is obviously not an important pioneer decomposer of Norway spruce needles. The diversity of fungal individuals drops sharply when needles start to decompose. Thus, in single needles the decomposing mycota is considerably less diverse than the endophytic mycota.

  19. PERTINENT DRY NEEDLING CONSIDERATIONS FOR MINIMIZING ADVERSE EFFECTS - PART TWO.

    Science.gov (United States)

    Halle, John S; Halle, Rob J

    2016-10-01

    Dry needling (DN) is an evidence based treatment technique that is accepted and used by physical therapists in the United States. This clinical commentary is the second in a two-part series outlining some of the pertinent anatomy and other issues that are needed for optimal utilization of this treatment modality. Part one was an overview of the thorax with a summary of reported adverse effects (AEs) and the underlying anatomy that could be used to minimize patient risk. As is the case with any intervention, the technique of dry needling has some inherent patient risk. The incidence of AEs with this procedure is typically low, ranging from zero to approximately 10 percent. Knowledge of the underlying anatomy can be a key factor associated with decreasing the likelihood of an AE. The second part of this clinical commentary goes beyond the thorax, to explore the anatomy associated with dry needling the abdomen, pelvis, and back. In the abdomen, pelvis and back, dry needling can penetrate the peritoneal cavity or adjacent organs, resulting in AEs. A physiological reaction that is an AE secondary to a needle insertion, pain or fear, is an autonomic vasovagal response. Additionally, suggestions for dealing with the fearful patient, the obese patient, universal precautions, and other clinical considerations, are discussed. The purpose of parts one and part two of this clinical commentary is to minimize the risk of a dry needling AE. Dry needling is an effective adjunctive treatment procedure that is within the recognized scope of practice of the physical therapist. An evidence-based implementation of the procedure must be based on a thorough understanding of the underlying anatomy and the potential risks, with risks communicated to patients via informed consent. Level 5.

  20. PERTINENT DRY NEEDLING CONSIDERATIONS FOR MINIMIZING ADVERSE EFFECTS - PART ONE.

    Science.gov (United States)

    Halle, John S; Halle, Rob J

    2016-08-01

    Dry needling is an evidence-based treatment technique that is accepted and used by physical therapists in the United States. This treatment approach focuses on releasing or inactivating muscular trigger points to decrease pain, reduce muscle tension, and assist patients with an accelerated return to active rehabilitation. While commonly used, the technique has some patient risk and value of the treatment should be based on benefit compared to the potential risk. Adverse effects (AEs) with dry needling can be mild or severe, with overall incidence rates varying from zero to rates of approximately 10 percent. While mild AEs are the rule, any procedure that involves a needle insertion has the potential for an AE, with select regions and the underlying anatomy increasing the risk. Known significant AEs from small diameter needle insertion include pneumothorax, cardiac tamponade, hematoma, infection, central nervous system injury, and other complications. Underlying anatomy across individuals has variability, requiring an in-depth knowledge of anatomy prior to any needle placement. This commentary is an overview of pertinent anatomy in the region of the thorax, with a 'part two' that addresses the abdomen, pelvis, back, vasovagal response, informed consent and other pertinent issues. The purpose of the commentary is to minimize the risk of a dry needling AE. Dry needling is an effective adjunct treatment procedure that is within the recognized scope of physical therapy practice. Physical therapy education and training provides practitioners with the anatomy, basic sciences, and clinical foundation to use this intervention safely and effectively. A safe and evidenced-based implementation of the procedure is based on a thorough understanding of the underlying anatomy and the potential risks, with risks coordinated with patients via informed consent. Level 5.

  1. Students as effective harm reductionists and needle exchange organizers.

    Science.gov (United States)

    Barbour, Kyle; McQuade, Miriam; Brown, Brandon

    2017-03-17

    Needle exchange programs are safe, highly effective programs for promoting health among people who inject drugs. However, they remain poorly funded, and often illegal, in many places worldwide due to fear and stigma surrounding drug use. Continued advocacy, education, and implementation of new needle exchanges are thus essential to improve public health and reduce structural inequality. We argue that students, and especially professional and graduate students, have the potential to play an important role in advancing harm reduction. Students benefit from the respect given to the professions they are training to enter, which gives them leverage to navigate the political hurdles often faced by needle exchange organizers, especially in areas that presently lack services. In addition, due to their relative simplicity, needle exchanges do not require much of the licensing, clinical knowledge, and infrastructure associated with more traditional student programs, such as student-run free medical clinics. Students are capable of learning harm reduction cultural approaches and techniques if they remain humble, open-minded, and seek the help of the harm reduction community. Consequently, students can generate tremendous benefits to their community without performing beyond their appropriate clinical limitations. Students benefit from organizing needle exchanges by gaining applied experience in advocacy, organization-building, and political finesse. Working in a needle exchange significantly helps erode stigma against multiple marginalized populations. Students in health-related professions additionally learn clinically-relevant knowledge that is often lacking from their formal training, such as an understanding of structural violence and inequality, root causes of substance use, client-centered approaches to health services, and interacting with clients as peers, rather than through the standard hierarchical medical interaction. We therefore encourage students to learn about

  2. Semi-Automated Needle Steering in Biological Tissue Using an Ultrasound-Based Deflection Predictor.

    Science.gov (United States)

    Khadem, Mohsen; Rossa, Carlos; Usmani, Nawaid; Sloboda, Ron S; Tavakoli, Mahdi

    2017-04-01

    The performance of needle-based interventions depends on the accuracy of needle tip positioning. Here, a novel needle steering strategy is proposed that enhances accuracy of needle steering. In our approach the surgeon is in charge of needle insertion to ensure the safety of operation, while the needle tip bevel location is robotically controlled to minimize the targeting error. The system has two main components: (1) a real-time predictor for estimating future needle deflection as it is steered inside soft tissue, and (2) an online motion planner that calculates control decisions and steers the needle toward the target by iterative optimization of the needle deflection predictions. The predictor uses the ultrasound-based curvature information to estimate the needle deflection. Given the specification of anatomical obstacles and a target from preoperative images, the motion planner uses the deflection predictions to estimate control actions, i.e., the depth(s) at which the needle should be rotated to reach the target. Ex-vivo needle insertions are performed with and without obstacle to validate our approach. The results demonstrate the needle steering strategy guides the needle to the targets with a maximum error of 1.22 mm.

  3. Generic Crystalline Disposal Reference Case

    Energy Technology Data Exchange (ETDEWEB)

    Painter, Scott Leroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chu, Shaoping [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Harp, Dylan Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Perry, Frank Vinton [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wang, Yifeng [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-20

    A generic reference case for disposal of spent nuclear fuel and high-level radioactive waste in crystalline rock is outlined. The generic cases are intended to support development of disposal system modeling capability by establishing relevant baseline conditions and parameters. Establishment of a generic reference case requires that the emplacement concept, waste inventory, waste form, waste package, backfill/buffer properties, EBS failure scenarios, host rock properties, and biosphere be specified. The focus in this report is on those elements that are unique to crystalline disposal, especially the geosphere representation. Three emplacement concepts are suggested for further analyses: a waste packages containing 4 PWR assemblies emplaced in boreholes in the floors of tunnels (KBS-3 concept), a 12-assembly waste package emplaced in tunnels, and a 32-assembly dual purpose canister emplaced in tunnels. In addition, three failure scenarios were suggested for future use: a nominal scenario involving corrosion of the waste package in the tunnel emplacement concepts, a manufacturing defect scenario applicable to the KBS-3 concept, and a disruptive glaciation scenario applicable to both emplacement concepts. The computational approaches required to analyze EBS failure and transport processes in a crystalline rock repository are similar to those of argillite/shale, with the most significant difference being that the EBS in a crystalline rock repository will likely experience highly heterogeneous flow rates, which should be represented in the model. The computational approaches required to analyze radionuclide transport in the natural system are very different because of the highly channelized nature of fracture flow. Computational workflows tailored to crystalline rock based on discrete transport pathways extracted from discrete fracture network models are recommended.

  4. Fracking, wastewater disposal, and earthquakes

    Science.gov (United States)

    McGarr, Arthur

    2016-03-01

    In the modern oil and gas industry, fracking of low-permeability reservoirs has resulted in a considerable increase in the production of oil and natural gas, but these fluid-injection activities also can induce earthquakes. Earthquakes induced by fracking are an inevitable consequence of the injection of fluid at high pressure, where the intent is to enhance permeability by creating a system of cracks and fissures that allow hydrocarbons to flow to the borehole. The micro-earthquakes induced during these highly-controlled procedures are generally much too small to be felt at the surface; indeed, the creation or reactivation of a large fault would be contrary to the goal of enhancing permeability evenly throughout the formation. Accordingly, the few case histories for which fracking has resulted in felt earthquakes have been due to unintended fault reactivation. Of greater consequence for inducing earthquakes, modern techniques for producing hydrocarbons, including fracking, have resulted in considerable quantities of coproduced wastewater, primarily formation brines. This wastewater is commonly disposed by injection into deep aquifers having high permeability and porosity. As reported in many case histories, pore pressure increases due to wastewater injection were channeled from the target aquifers into fault zones that were, in effect, lubricated, resulting in earthquake slip. These fault zones are often located in the brittle crystalline rocks in the basement. Magnitudes of earthquakes induced by wastewater disposal often exceed 4, the threshold for structural damage. Even though only a small fraction of disposal wells induce earthquakes large enough to be of concern to the public, there are so many of these wells that this source of seismicity contributes significantly to the seismic hazard in the United States, especially east of the Rocky Mountains where standards of building construction are generally not designed to resist shaking from large earthquakes.

  5. Waste Disposal: The PRACLAY Programme

    International Nuclear Information System (INIS)

    De Bruyn, D.

    2000-01-01

    Principal achievements in 2000 with regard to the PRACLAY programme are presented. The PRACLAY project has been conceived: (1) to demonstrate the construction and the operation of a gallery for the disposal of HLW in a clay formation; (2) to improve knowledge on deep excavations in clay through modelling and monitoring; (3) to design, install and operate a complementary mock-up test (OPHELIE) on the surface. In 1999, efforts were focussed on the operation of the OPHELIE mock-up and the CLIPEX project to monitor the evolution of hydro-mechanical parameters of the Boom Clay Formation near the face of a gallery during excavation

  6. Geologic disposal of radioactive waste

    International Nuclear Information System (INIS)

    Tassoni, E.; Giulianelli, G.; Testa, L.; Bocola, W.; Girolimetti, G.; Giacani, G.

    1983-01-01

    The heat dissipation arising from the radioactive decay constitutes an important problem of the geological disposal of high level radioactive waste. A heating experiment was carried out in a clay quarry near Monterotondo (Rome), at 6.4 M in depth by means of a heater whose thermal power ranged from 250 to 500 watt. The experimental results fit well the theoretical values and show that the clay is a homogeneous and isotropic medium. The clay thermal conductivity, which was deducted by means of the ''curve fitting'' method, ranges from 0.015 to 0.017 watt/C

  7. SNS Proton Beam Window Disposal

    Directory of Open Access Journals (Sweden)

    Popova Irina

    2017-01-01

    Full Text Available In order to support the disposal of the proton beam window assembly of the Spallation Neutron Source beamline to the target station, waste classification analyses are performed. The window has a limited life-time due to radiation-induced material damage. Analyses include calculation of the radionuclide inventory and shielding analyses for the transport package/container to ensure that the container is compliant with the transportation and waste management regulations. In order to automate this procedure and minimize manual work a script in Perl language was written.

  8. MAINTENANCE PLANNING OF THE SEWING NEEDLES OF SIMPLE SEWING MACHINES

    Directory of Open Access Journals (Sweden)

    ŞUTEU Marius Darius

    2017-05-01

    Full Text Available The effectiveness of simple sewing machines can be increased through the planning of predictive maintenance activities. The monitoring of the technical condition of the sewing needles of simple sewing machines was based on the measurement of their noise level. For this purpose a Center 322 sonometer was used, while the data obtained during the monitoring process was analyzed through the E322 software. The working speed of the simple sewing machine that was used for obtaining the experimental results varied from 200 stitches/minute to 4000 stitches/minute. The noise levels of a new needle at the working speed of 200 stitches/minute and 4000 stitches/minute were measured. The noise levels for a fault needle at the same working speed of 200 stitches/minute, respectively 4000 stitches/minute were also measured. Using Fuzzy Logic Toolbox ™ module of Matlab®, a decision-making system for determining when replacement of the sewing needles of simple sewing machines should be performed was developed. A case study illustrates the employment of the decision-making system based on fuzzy logic for a simple sewing machine. By replacing the sewing needles of simple sewing machines at the time specified through the decision-making system based on fuzzy logic, the occurrence of the failure can be prevented and the quality of textile products can be improved.

  9. Computer-vision-based inspecting system for needle roller bearing

    Science.gov (United States)

    Li, Wei; He, Tao; Zhong, Fei; Wu, Qinhua; Zhong, Yuning; Shi, Teiling

    2006-11-01

    A Computer Vision based Inspecting System for Needle Roller Bearing (CVISNRB) is proposed in the paper. The characteristic of technology, main functions and principle of CVISNRB are also introduced. CVISNRB is composed of a mechanic transmission and an automatic feeding system, an imaging system, software arithmetic, an automatic selecting system of inspected bearing, a human-computer interaction, a pneumatic control system, an electric control system and so on. The computer vision technique is introduced in the inspecting system for needle roller bearing, which resolves the problem of the small needle roller bearing inspecting in bearing production business enterprise, raises the speed of the inspecting, and realizes the automatic untouched and on-line examination. The CVISNRB can effectively examine the loss of needle and give the accurate number. The accuracy can achieve 99.5%, and the examination speed can arrive 15 needle roller bearings each minute. The CVISNRB has none malfunction in the actual performance in the past half year, and can meet the actual need.

  10. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  11. Laryngeal chondrosarcoma diagnosed by core-needle biopsy.

    Science.gov (United States)

    Miyamaru, Satoru; Haba, Koichi

    2014-01-01

    We report a case of chondrosarcoma of the larynx, diagnosed by a percutaneous core-needle biopsy (CNB). Cartilaginous tumors of the larynx are usually diagnosed by biopsy with direct laryngomicroscopy under general anesthesia. However, patients find it difficult to undergo a biopsy under general anesthesia, for physical, economic, and social reasons. Instead, we can readily detect and sample tumors of the larynx using ultrasound under local anesthesia with reduced stress. Concerning needle-puncture biopsies, including fine-needle aspiration cytology (FNAC) and CNB, some studies have reported needle track dissemination, a possible complication in patients with malignant tumors. Thus, in the head and neck region, we generally use FNAC for biopsies, not CNB. However, it can be difficult to diagnose bone tumors by cytology alone. Regarding primary bone tumors, only one study has reported needle track dissemination by CNB, in osteosarcoma of the femur. Additionally, this complication has not been reported before with chondrosarcoma anywhere in the body. To our knowledge, this is the first report concerning chondrosarcoma of the larynx diagnosed by percutaneous CNB. We recommend CNB as a useful and safe diagnostic technique for primary bone tumors in the head and neck region. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  13. Disposable optics for microscopy diagnostics.

    Science.gov (United States)

    Vilmi, Pauliina; Varjo, Sami; Sliz, Rafal; Hannuksela, Jari; Fabritius, Tapio

    2015-11-20

    The point-of-care testing (POCT) is having increasing role on modern health care systems due to a possibility to perform tests for patients conveniently and immediately. POCT includes lot of disposable devices because of the environment they are often used. For a disposable system to be reasonably utilized, it needs to be high in quality but low in price. Optics based POCT systems are interesting approach to be developed, and here we describe a low-cost fabrication process for microlens arrays for microscopy. Lens arrays having average lens diameter of 222 μm with 300 μm lens pitch were fabricated. The lenses were characterized to have standard deviation of 0.06 μm in height and 4.61 μm in diameter. The resolution limit of 3.9μm is demonstrated with real images, and the images were compared with ones made with glass and polycarbonate lens arrays. The image quality is at the same level than with the glass lenses and the manufacturing costs are very low, thus making them suitable for POCT applications.

  14. Shallow ground disposal of radioactive wastes

    International Nuclear Information System (INIS)

    1981-01-01

    This guidebook outlines the factors to be considered in site selection, design, operation, shut-down and surveillance as well as the regulatory requirements of repositories for safe disposal of radioactive waste in shallow ground. No attempt is made to summarize the existing voluminous literature on the many facets of radioactive waste disposal. In the context of this guidebook, shallow ground disposal refers to the emplacement of radioactive waste, with or without engineered barriers, above or below the ground surface, where the final protective covering is of the order of a few metres thick. Deep geological disposal and other underground disposal methods, management of mill tailings and disposal into the sea have been or will be considered in other IAEA publications. These guidelines have been made sufficiently general to cover a broad variety of climatic, hydrogeological and biological conditions. They may need to be interpreted or modified to reflect local conditions and national regulations

  15. Disposal of tritium-exposed metal hydrides

    International Nuclear Information System (INIS)

    Nobile, A.; Motyka, T.

    1991-01-01

    A plan has been established for disposal of tritium-exposed metal hydrides used in Savannah River Site (SRS) tritium production or Materials Test Facility (MTF) R ampersand D operations. The recommended plan assumes that the first tritium-exposed metal hydrides will be disposed of after startup of the Solid Waste Disposal Facility (SWDF) Expansion Project in 1992, and thus the plan is consistent with the new disposal requiremkents that will be in effect for the SWDF Expansion Project. Process beds containing tritium-exposed metal hydride powder will be disposed of without removal of the powder from the bed; however, disposal of tritium-exposed metal hydride powder that has been removed from its process vessel is also addressed

  16. Classification and disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1990-01-01

    This paper reviews the historical development in the U.S. of definitions and requirements for permanent disposal of different classes of radioactive waste. We first consider the descriptions of different waste classes that were developed prior to definitions in laws and regulations. These descriptions usually were not based on requirements for permanent disposal but, rather, on the source of the waste and requirements for safe handling and storage. We then discuss existing laws and regulations for disposal of different waste classes. Current definitions of waste classes are largely qualitative, and thus somewhat ambiguous, and are based primarily on the source of the waste rather than the properties of its radioactive constituents. Furthermore, even though permanent disposal is clearly recognized as the ultimate goal of radioactive water management, current laws and regulations do not associated the definitions of different waste classes with requirement for particular disposal systems. Thus, requirements for waste disposal essentially are unaffected by ambiguities in the present waste classification system

  17. Fabrication of Silk Nanofibres with Needle and Roller Electrospinning Methods

    Directory of Open Access Journals (Sweden)

    Nongnut Sasithorn

    2014-01-01

    Full Text Available In this study, silk nanofibres were prepared by electrospinning from silk fibroin in a mixture of formic acid and calcium chloride. A needle and a rotating cylinder were used as fibre generators in the spinning process. The influences of the spinning electrode and spinning parameters (silk concentration and applied voltage on the spinning process, morphology of the obtained fibres, and the production rate of the spinning process were examined. The concentration of the spinning solution influenced the diameter of the silk electrospun fibres, with an increase in the concentration increasing the diameters of the fibres in both spinning systems. The diameters of the electrospun fibres produced by roller electrospinning were greater than those produced by needle electrospinning. Moreover, increasing the concentration of the silk solution and the applied voltage in the spinning process improved the production rate in roller electrospinning but had less influence on the production rate in needle electrospinning.

  18. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  19. Spruce needles used as radioecological biotracers; Fichtennadeln als radiooekologische Bioindikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, C.; Gruber, V.; Baumgartner, A. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; Idinger, J. [Technische Univ. Wien (Austria). Atominst.; Fuerst, A. [BFW - Bundesforschungs- und Ausbildungszentrum fuer Wald, Naturgefahren und Landschaft, Wien (Austria). Inst. fuer Waldschutz, Pflanzenanalyse; Maringer, F.J. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; BEV - Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2009-07-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: {sup 137}Cs, {sup 40}K, {sup 210}Pb, {sup 226}Ra, {sup 228}Ra, {sup 238}U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  20. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    Non-compliance in children receiving growth hormone (GH) treatment is often caused by pain on injection and difficulties in administration of GH. It has been suggested that automatic needle insertion diminishes pain perception. We quantitatively measured pain intensity on injection with two...... prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  1. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  2. Comparison between the Needle and Roller Electrospinning of Polyvinylbutyral

    Directory of Open Access Journals (Sweden)

    F. Yener

    2012-01-01

    Full Text Available The effect of the concentration of polyvinylbutyral solution on the process throughput and fibre properties was studied in needle and roller electrospinning. Whereas the polymer throughput is an optional independent parameter in needle electrospinning, it is a dependent parameter that is affected by both the material and process parameters in roller electrospinning. Polymer throughput increases considerably with an increasing concentration of polymer solutions in roller electrospinning. The properties of the nanofibers and the quality of the nanofiber layers were also studied. Fibre diameters increase with an increasing concentration in both techniques. Fibre diameters produced by needle electrospinning are smaller than those produced by roller electrospinning. The distribution of fibre diameters is rather narrow and not significantly dependent on the concentration of solutions in either technique.

  3. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle

    Directory of Open Access Journals (Sweden)

    Zhouwen Tang

    2016-01-01

    Full Text Available Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients and cholangitis (1 patient. Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  4. General criteria for radioactive waste disposal

    International Nuclear Information System (INIS)

    Maxey, M.N.; Musgrave, B.C.; Watkins, G.B.

    1979-01-01

    Techniques are being developed for conversion of radioactive wastes to solids and their placement into repositories. Criteria for such disposal are needed to assure protection of the biosphere. The ALARA (as low as reasonably achievable) principle should be applicable at all times during the disposal period. Radioactive wastes can be categorized into three classes, depending on the activity. Three approaches were developed for judging the adequacy of disposal concepts: acceptable risk, ore body comparison, and three-stage ore body comparison

  5. The capacitated distribution and waste disposal problem

    OpenAIRE

    Bloemhof-Ruwaard, Jacqueline; Salomon, Marc; Wassenhove, Luk

    1996-01-01

    textabstractWe study the problem of the simultaneous design of a distribution network with plants and waste disposal units, and the coordination of product flows and waste flows within this network. The objective is to minimize the sum of fixed costs for opening plants and waste disposal units, and variable costs related to product and waste flows. The problem is complicated by (i) capacity constraints on plants and waste disposal units, (ii) service requirements (i.e. production must cover t...

  6. Shallow land disposal of radioactive waste

    International Nuclear Information System (INIS)

    1987-01-01

    The application of basic radiation protection concepts and objectives to the disposal of radioactive wastes requires the development of specific reference levels or criteria for the radiological acceptance of each type of waste in each disposal option. This report suggests a methodology for the establishment of acceptance criteria for the disposal of low-level radioactive waste containing long-lived radionuclides in shallow land burial facilities

  7. Verification and validation for waste disposal models

    International Nuclear Information System (INIS)

    1987-07-01

    A set of evaluation criteria has been developed to assess the suitability of current verification and validation techniques for waste disposal methods. A survey of current practices and techniques was undertaken and evaluated using these criteria with the items most relevant to waste disposal models being identified. Recommendations regarding the most suitable verification and validation practices for nuclear waste disposal modelling software have been made

  8. Environmental Policy with Collective Waste Disposal

    OpenAIRE

    Hamilton, Stephen F.; Sproul, Thomas W.; Sunding, David; Zilberman, David

    2013-01-01

    Centralized collection and disposal is an integral component of waste management strategies for many solid and liquid wastes, and carbon capture and storage is currently being considered for gaseous waste. In this paper we show how collective waste disposal systems introduce essential changes in the design of optimal environmental policy. Absent collective disposal, an optimal environmental policy imposes relatively stringent regulations on polluters in regions where local environmental damag...

  9. Commercial mixed waste treatment and disposal

    International Nuclear Information System (INIS)

    Vance, J.K.

    1994-01-01

    At the South Clive, Utah, site, Envirocare of Utah, Inc., (Envirocare), currently operates a commercial low-activity, low-level radioactive waste facility, a mixed waste RCRA Part B storage and disposal facility, and an 11e.(2) disposal facility. Envirocare is also in the process of constructing a Mixed Waste Treatment Facility. As the nation's first and only commercial treatment and disposal facility for such waste, the information presented in this segment will provide insight into their current and prospective operations

  10. Endophyte communities vary in the needles of Norway spruce clones.

    Science.gov (United States)

    Rajala, Tiina; Velmala, Sannakajsa M; Tuomivirta, Tero; Haapanen, Matti; Müller, Michael; Pennanen, Taina

    2013-03-01

    Endophytic fungi show no symptoms of their presence but can influence the performance and vitality of host trees. The potential use of endophytes to indicate vitality has been previously realized, but a standard protocol has yet to be developed due to an incomplete understanding of the factors that regulate endophyte communities. Using a culture-free molecular approach, we examined the extent to which host genotype influences the abundance, species richness, and community composition of endophytic fungi in Norway spruce needles. Briefly, total DNA was extracted from the surface-sterilized needles of 30 clones grown in a nursery field and the copy number of the fungal internal transcribed spacer (ITS) region of ribosomal DNA was estimated by quantitative PCR. Fungal species richness and community composition were determined by denaturing gradient gel electrophoresis and DNA sequencing. We found that community structure and ITS copy number varied among spruce clones, whereas species richness did not. Host traits interacting with endophyte communities included needle surface area and the location of cuttings in the experimental area. Although Lophodermium piceae is considered the dominant needle endophyte of Norway spruce, we detected this species in only 33% of samples. The most frequently observed fungus (66%) was the potentially pathogenic Phoma herbarum. Interestingly, ITS copy number of endophytic fungi correlated negatively with the richness of ectomycorrhizal fungi and thus potential interactions between fungal communities and their influence on the host tree are discussed. Our results suggest that in addition to environmental factors, endophyte communities of spruce needles are determined by host tree identity and needle surface area. Copyright © 2013 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  11. Recovery of equine oocytes by scraping of the follicular wall with different specifications of needles and morphological analysis of cumulus oophorus

    Directory of Open Access Journals (Sweden)

    Suellen Miguez González

    2015-12-01

    Full Text Available In follicular aspiration, physical aspects are of high significance for the technique to succeed, such as vacuum pressure, caliber of the needle and the way the follicular wall curettage is performed. The aim of this study was to investigate the recovery rate of equine oocytes aspirated by scraping of the follicular wall, testing different calibers of disposable needles, as well as the morphological evaluation of the cumulus oophorus complexes (COCs. Mares ovaries (n=447 obtained at a local slaughterhouse were transported to the laboratory in a thermal container (20 °C and had the tunica albuginea and connective tissues dissected. The aspirated follicles had 10 to 25 mm in diameter, and 30x8 (21G 1 ¼ or 40x12 (18G 1 ½ needles were used for the aspiration, forming group A (G-A and group B (G-B, respectively. In G-A and G-B, 480 and 548 follicles were aspirated, respectively. Under the stereomicroscope, the oocytes were evaluated according to the quality of the ooplasm and characteristics of the cumulus cells (grade I, II, III and denuded. The statistical analysis was performed using the Student’s t-test, logistic regression and test of proportions, and differences were considered significant when P<0.05. There was no difference between recovery rates of groups G-A (66.5%; 330/496 and G-B (65.5%; 359/548. In the G-A group, grade II oocytes were related to higher recovery rates (46.9%; 145/330 than grade I (23.6%; 72/330, grade III (20.6%; 59/330 and denuded oocytes (8.5%; 24/330; P<0.05. However, in G-B, there was no statistical difference regarding the quality of the recovered oocytes: grade I (23.4%; 77/359, grade II (43.2%; 145/359, grade III (22.5%; 73/359 and denuded (11.1%; 32/359. The 30x8 (21G 1 ¼ needle provided a higher proportion of grades I and II oocytes than the 40x12 (18G 1 ½ needle, with 72.4% (239/330 and 65% (233/359; P<0.05, respectively. Both calibers of needles tested in this study provide efficient oocyte recovery

  12. ICRP guidance on radioactive waste disposal

    International Nuclear Information System (INIS)

    Cooper, J.R.

    2002-01-01

    The International Commission on Radiological Protection (ICRP) issued recommendations for a system of radiological protection in 1991 as the 1990 Recommendations. Guidance on the application of these recommendations in the general area of waste disposal was issued in 1997 as Publication 77 and guidance specific to disposal of solid long-lived radioactive waste was issued as Publication 81. This paper summarises ICRP guidance in radiological protection requirements for waste disposal concentrating on the ones of relevance to the geological disposal of solid radioactive waste. Suggestions are made for areas where further work is required to apply the ICRP guidance. (author)

  13. Geohydrology of industrial waste disposal site

    International Nuclear Information System (INIS)

    Gaynor, R.K.

    1984-01-01

    An existing desert site for hazardous chemical and low-level radioactive waste disposal is evaluated for suitability. This site is characterized using geologic, geohydrologic, geochemical, and other considerations. Design and operation of the disposal facility is considered. Site characteristics are also evaluated with respect to new and proposed regulatory requirements under the Resource Conservation and Recovery Act (1976) regulations, 40 CFR Part 264, and the ''Licensing Requirements for Landfill Disposal of Radioactive Waste,'' 10 CFR Part 61. The advantages and disadvantages of siting new disposal facilities in similar desert areas are reviewed and contrasted to siting in humid locations

  14. Geohydrology of industrial waste disposal site

    International Nuclear Information System (INIS)

    Gaynor, R.K.

    1984-01-01

    An existing desert site for hazardous chemical and low-level radioactive waste disposal is evaluated for suitability. This site is characterized using geologic, geohydrologic, geochemical, and other considerations. Design and operation of the disposal facility is considered. Site characteristics are also evaluated with respect to new and proposed regulatory requirements under the Resource Conservation and Recovery Act (1976) regulations, 40 CFR Part 264, and the ''Licensing Requirements for Landfill Disposal of Radioactive Waste,'' 10 CRF Part 61. The advantages and disadvantages of siting new disposal facilities in similar desert areas are reviewed and contrasted to siting in humid locations

  15. Post-disposal safety assessment of toxic and radioactive waste: waste types, disposal practices, disposal criteria, assessment methods and post-disposal impacts

    International Nuclear Information System (INIS)

    Torres, C.; Simon, I.; Little, R.H.; Charles, D.; Grogan, H.A.; Smith, G.M.; Sumerling, T.J.; Watkins, B.M.

    1993-01-01

    The need for safety assessments of waste disposal stems not only from the implementation of regulations requiring the assessment of environmental effects, but also from the more general need to justify decisions on protection requirements. As waste-disposal methods have become more technologically based, through the application of more highly engineered design concepts and through more rigorous and specific limitations on the types and quantities of the waste disposed, it follows that assessment procedures also must become more sophisticated. It is the overall aim of this study to improve the predictive modelling capacity for post-disposal safety assessments of land-based disposal facilities through the development and testing of a comprehensive, yet practicable, assessment framework. This report records all the work which has been undertaken during Phase 1 of the study. Waste types, disposal practices, disposal criteria and assessment methods for both toxic and radioactive waste are reviewed with the purpose of identifying those features relevant to assessment methodology development. Difference and similarities in waste types, disposal practices, criteria and assessment methods between countries, and between toxic and radioactive wastes are highlighted and discussed. Finally, an approach to identify post-disposal impacts, how they arise and their effects on humans and the environment is described

  16. The Gothic arch (needle point) tracing and condylar inclination.

    Science.gov (United States)

    el-Gheriani, A S; Winstanley, R B

    1987-11-01

    The records of 11 patients referred for treatment of TMJ disorders were used to compare condylar inclination found by drawing a tangent and by using a mathematic technique. Needle point tracing angles were also measured for the same patients and were compared with the condylar inclination. It can be concluded that (1) the mathematic technique outlined records a more accurate condylar angulation, and (2) there is a great variation in condylar inclination values between patients and between left and right sides of the same patient, and (3) there is no direct relationship between condylar inclination and the needle point tracing angle.

  17. Direct trocar insertion vs. Verres needle use for laparoscopic sterilization.

    Science.gov (United States)

    Borgatta, L; Gruss, L; Barad, D; Kaali, S G

    1990-09-01

    A randomized, prospective trial was designed to compare direct trocar insertion with prior peritoneal insufflation with a Verres needle for laparoscopic tubal sterilization. Direct trocar insertion resulted in fewer instrument insertions (21.8% vs. 7.8%) and use of smaller volumes of CO2 (2.67 vs. 2.32 L). Direct trocar use resulted in a decrease in operating time from 9 minutes, 40 seconds in the needle group to 7 minutes, 30 seconds in the trocar group. Minor omental injuries occurred in a small percentage of each group, while serious complications occurred once in each group.

  18. Senate follows House in banning funds for needle swaps.

    Science.gov (United States)

    1998-06-26

    The U.S. Senate has approved anti-drug legislation which permanently bans Federal funding for needle-exchange programs. Senator Paul Coverdell of Georgia added the anti-drug legislation to a tobacco bill that is very important to many politicians. During the Senate approval process of this tobacco bill, needle exchange programs were hardly mentioned. If the combined bill reaches the President, it is believed that he will sign it because of the Administration's interest in tobacco legislation. If, however, the tobacco bill is not approved, the funding ban may be attached to other, less controversial legislation.

  19. Laparoscopic removal of a needle from the pancreas

    Directory of Open Access Journals (Sweden)

    Amit Jain

    2013-01-01

    Full Text Available Foreign bodies inside the pancreas are rare and usually occur after the ingestion of sharp objects like fish bone, sewing needle and toothpick. Most of the ingested foreign bodies pass spontaneously through the anus without being noticed but about 1% of them can perforate through the wall of stomach or duodenum to reach solid organs like pancreas or liver. Once inside the pancreas they can produce complications like abscess, pseudoaneurysm or pancreatits. Foreign bodies of pancreas should be removed by endoscopic or surgical methods. We hereby report our experience of successful removal one a sewing needle from pancreas.

  20. Effect of fascia dry needling on non-specific thoracic pain - A proposed dry needling grading system.

    Science.gov (United States)

    Anandkumar, Sudarshan; Manivasagam, Murugavel

    2017-05-01

    This case report describes a 42-year-old female who presented with complaints of diffuse pain in her thoracic paraspinal region from T2 to T7. Physical examination revealed tenderness, increased turgor and restriction of her superficial fascia. A potential first time description of successful management utilizing fascia dry needling is described in this report with improvements noted in pain, range of motion, and functional activities. The patient was discharged from physiotherapy after four treatment sessions, and a follow-up after 3 months revealed that she was pain free and fully functional. A grading system (Sudarshan and Murugavel Dry Needling Grading Scale © ) is proposed describing the various grades of dry needling to guide clinical reasoning and decision-making.

  1. Alternative Concept to Enhance the Disposal Efficiency for CANDU Spent Fuel Disposal System

    International Nuclear Information System (INIS)

    Lee, Jong Youl; Cho, Dong Geun; Kook, Dong Hak; Lee, Min Soo; Choi, Heui Joo

    2011-01-01

    There are two types of nuclear reactors in Korea and they are PWR type and CANDU type. The safe management of the spent fuels from these reactors is very important factor to maintain the sustainable energy supply with nuclear power plant. In Korea, a reference disposal system for the spent fuels has been developed through a study on the direct disposal of the PWR and CANDU spent fuel. Recently, the research on the demonstration and the efficiency analyses of the disposal system has been performed to make the disposal system safer and more economic. PWR spent fuels which include a lot of reusable material can be considered being recycled and a study on the disposal of HLW from this recycling process is being performed. CANDU spent fuels are considered being disposed of directly in deep geological formation, since they have little reusable material. In this study, based on the Korean Reference spent fuel disposal System (KRS) which was to dispose of both PWR type and CANDU type, the more effective CANDU spent fuel disposal systems were developed. To do this, the disposal canister for CANDU spent fuels was modified to hold the storage basket for 60 bundles which is used in nuclear power plant. With these modified disposal canister concepts, the disposal concepts to meet the thermal requirement that the temperature of the buffer materials should not be over 100 .deg. C were developed. These disposal concepts were reviewed and analyzed in terms of disposal effective factors which were thermal effectiveness, U-density, disposal area, excavation volume, material volume etc. and the most effective concept was proposed. The results of this study will be used in the development of various wastes disposal system together with the HLW wastes from the PWR spent fuel recycling process.

  2. Bladder neck needle suspension for urinary incontinence in women.

    Science.gov (United States)

    Glazener, Cathryn Ma; Cooper, Kevin; Mashayekhi, Atefeh

    2017-07-25

    Bladder neck needle suspension is an operation traditionally used for moderate or severe stress urinary incontinence in women. About a third of adult women experience some urinary incontinence, and about a third of these have moderate or severe symptoms. Stress urinary incontinence (SUI) imposes significant health and economic burdens on society and the women affected. To determine the effects of needle suspension on stress or mixed urinary incontinence in comparison with other management options. We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 12 November 2014), and the reference lists of relevant articles. Randomised or quasi-randomised trials that included needle suspension for the treatment of urinary incontinence. At least two authors assessed trials and extracted data independently. Two trial investigators provided additional information. We identified 10 trials, which included 375 women having six different types of needle suspension procedures and 489 who received comparison interventions. Needle suspensions were more likely to fail than open abdominal retropubic suspension. There was a higher subjective failure rate after the first year (91/313 (29%) failed versus 47/297 (16%) failed after open abdominal retropubic suspension). The risk ratio (RR) was 2.00 (95% confidence interval (CI) 1.47 to 2.72), although the difference in peri-operative complications was not significant (17/75 (23%) versus 12/77 (16%); RR 1.44, 95% CI 0.73 to 2.83). There were no significant differences for the other outcome measures. This effect was seen in both women with primary incontinence and women with recurrent incontinence after failed primary operations. Needle suspensions may be as effective as anterior vaginal repair (50/156 (32

  3. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  4. Radioactive wastes and their disposal

    International Nuclear Information System (INIS)

    Neumann, L.

    1984-01-01

    The classification of radioactive wastes is given and the achievements evaluated in the disposal of radioactive wastes from nuclear power plants. An experimental pilot unit was installed at the Jaslovske Bohunice nuclear power plant for the bituminization of liquid radioactive wastes. UJV has developed a mobile automated high-output unit for cementation. In 1985 the unit will be tested at the Jaslovske Bohunice and the Dukovany nuclear power plants. A prototype press for processing solid wastes was manufactured which is in operation at the Jaslovske Bohunice plant. A solidification process for atypical wastes from long-term storage of spent fuel elements has been developed to be used for the period of nuclear power plant decommissioning. (E.S.)

  5. Nuclear waste disposal educational forum

    International Nuclear Information System (INIS)

    1982-01-01

    In keeping with a mandate from the US Congress to provide opportunities for consumer education and information and to seek consumer input on national issues, the Department of Energy's Office of Consumer Affairs held a three-hour educational forum on the proposed nuclear waste disposal legislation. Nearly one hundred representatives of consumer, public interest, civic and environmental organizations were invited to attend. Consumer affairs professionals of utility companies across the country were also invited to attend the forum. The following six papers were presented: historical perspectives; status of legislation (Senate); status of legislation (House of Representatives); impact on the legislation on electric utilities; impact of the legislation on consumers; implementing the legislation. All six papers have been abstracted and indexed for the Energy Data Base

  6. Ultimate disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Roethemeyer, H.

    1991-01-01

    The activities developed by the Federal Institution of Physical Engineering PTB and by the Federal Office for Radiation Protection (BfS) concentrated, among others, on work to implement ultimate storage facilities for radioactive wastes. The book illuminates this development from site designation to the preliminary evaluation of the Gorleben salt dome, to the preparation of planning documents proving that the Konrad ore mine is suitable for a repository. The paper shows the legal provisions involved; research and development tasks; collection of radioactive wastes ready for ultimate disposal; safety analysis in the commissioning and post-operational stages, and product control. The historical development of waste management in the Federal Republic of Germany and international cooperation in this area are outlined. (DG) [de

  7. Nuclear Waste Disposal Program 2016

    International Nuclear Information System (INIS)

    2016-12-01

    This comprehensive brochure published by the Swiss National Cooperative for the Disposal of Radioactive Waste (NAGRA) discusses the many important steps in the management of radioactive waste that have already been implemented in Switzerland. The handling and packaging of waste, its characterisation and inventorying, as well as its interim storage and transport are examined. The many important steps in Swiss management of radioactive waste already implemented and wide experience gained in carrying out the associated activities are discussed. The legal framework and organisational measures that will allow the selection of repository sites are looked at. The various aspects examined include the origin, type and volume of radioactive wastes, along with concepts and designs for deep geological repositories and the types of waste to be stored therein. Also, an implementation plan for the deep geological repositories, the required capacities and the financing of waste management activities are discussed as is NAGRA’s information concept. Several diagrams and tables illustrate the program

  8. Packages for radiactive waste disposal

    International Nuclear Information System (INIS)

    Oliveira, R. de.

    1983-01-01

    The development of multi-stage type package for sea disposal of compactable nuclear wastes, is presented. The basic requirements for the project followed the NEA and IAEA recommendations and observations of the solutions adopted by others countries. The packages of preliminary design was analysed, by computer, under several conditions arising out of its nature, as well as their conditions descent, dumping and durability in the deep of sea. The designed pressure equalization mechanic and the effect compacting on the package, by prototypes and specific tests, were studied. These prototypes were also submitted to the transport tests of the 'Regulament for the Safe Transport of Radioactive Materials'. Based on results of the testes and the re-evaluation of the preliminary design, final indications and specifications for excuting the package design, are presented. (M.C.K.) [pt

  9. National guideline of TENORM disposal

    International Nuclear Information System (INIS)

    Hamrah Mohd Ali

    1999-01-01

    Naturally Occurring Radioactive Material is a substance contain radioactive elements from uranium ( 238 U) and thorium ( 232 Th) series which have been present in the earth's crust since its formation. Meanwhile TENORM is produced from the NORM enhancement activities which has contributed radiation hazards to members of public, workers and the environment. In this situation the existing of Atomic Energy Licensing Board (AELB) is to protect public, workers and the environment from TENORM waste created from related industries. What ever methods of disposal, a proper waste management systems should be in placed to ensure the protection of human health and the environment now and in the future, without imposing undue burden on future generations should be taken into account. In comply with that philosophy, it is important for industries to comply with the Atomic Energy Licensing Act which has been enforced since 1985. (Author)

  10. Deep Borehole Disposal Safety Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Geoffrey A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Stein, Emily [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Price, Laura L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Tillman, Jack Bruce [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    This report presents a preliminary safety analysis for the deep borehole disposal (DBD) concept, using a safety case framework. A safety case is an integrated collection of qualitative and quantitative arguments, evidence, and analyses that substantiate the safety, and the level of confidence in the safety, of a geologic repository. This safety case framework for DBD follows the outline of the elements of a safety case, and identifies the types of information that will be required to satisfy these elements. At this very preliminary phase of development, the DBD safety case focuses on the generic feasibility of the DBD concept. It is based on potential system designs, waste forms, engineering, and geologic conditions; however, no specific site or regulatory framework exists. It will progress to a site-specific safety case as the DBD concept advances into a site-specific phase, progressing through consent-based site selection and site investigation and characterization.

  11. Instructive for disposal of fluorescent

    International Nuclear Information System (INIS)

    Salazar Vargas, Gerlin

    2014-01-01

    An instructive is established for the management system of waste fluorescent lamps, ensuring the storage, collection, transportation, and final disposal. The lamp is changed by an official of the Seccion de Matenimiento Construccion of the Oficina de Servicios Generales or is produced with the support of an official of the unit. The fluorescent should be deposited in stock of materials of the building maintenance section or unit specified with the help of a staff and in appropriate conditions. The fluorescent lamp is transported according to the guidelines in the manual. A responsible company is contracted by la Vicerrectoria de Administracion of the Universidad de Costa Rica dedicated to the transport and proper handling of fluorescent lamps [es

  12. Knowledge and practices about hospital waste disposal and universal safety precautions in class IV employee.

    Science.gov (United States)

    Megha, Khobragade; Daksha, Pandit

    2013-01-01

    Norms and guidelines are formed for safe disposal of hospital waste but question is whether these guidelines are being followed and if so, to what extent. Hence, this study was conducted with objective to study the knowledge and practices about hospital waste disposal and universal safety precautions in class IV employee and to study its relationship with education, occupation and training. A cross-sectional study was carried out in a teaching hospital in Mumbai using semi-structured questionnaire in which Class IV employee were included. Questionnaire was filled by face to face interview. Data were analyzed using SPSS. 48.7% Class IV employee were not trained. More than 40% were following correct practices about disinfection of infectious waste. None of the respondents were using protective footwear while handling hospital waste. Only 25.5% were vaccinated for hepatitis B. 16% had done HIV testing due to contact with blood, body fluid, needle stick injury. Knowledge and practices about hospital waste disposal and universal precaution were statistically significant in trained respondents. Training of employees should be given top priority; those already in service should be given on the job training at the earliest.

  13. Disposal options for disused radioactive sources

    International Nuclear Information System (INIS)

    2005-01-01

    This report presents a review of relevant information on the various technical factors and issues, as well as approaches and relevant technologies, leading to the identification of potential disposal options for disused radioactive sources. The report attempts to provide a logical 'road map' for the disposal of disused radioactive sources, taking into consideration the high degree of variability in the radiological properties of such types of radioactive waste. The use of borehole or shaft type repositories is highlighted as a potential disposal option, particularly for those countries that have limited resources and are looking for a simple, safe and cost effective solution for the disposal of their radioactive source inventories. It offers information about usage and characteristics of radioactive sources, disposal considerations, identification and screening of disposal options as well as waste packaging and acceptance criteria for disposal. The information provided in the report could be adapted or adopted to identify and develop specific disposal options suitable for the type and inventory of radioactive sources kept in storage in a given Member State

  14. Radioactive waste products - suitability for final disposal

    International Nuclear Information System (INIS)

    Merz, E.; Odoj, R.; Warnecke, E.

    1985-06-01

    48 papers were read at the conference. Separate records are available for all of them. The main problem in radioactive waste disposal was the long-term sealing to prevent pollution of the biosphere. Problems of conditioning, acceptance, and safety measures were discussed. Final disposal models and repositories were presented. (PW) [de

  15. Aujeszky's disease virus production in disposable bioreactor

    Indian Academy of Sciences (India)

    Aujeszky's disease virus, baby hamster kidney cells, cell culture, disposable bioreactor, virus titre. Abstract. A novel, disposable-bag bioreactor system that uses wave action for mixing and transferring oxygen was evaluated for BHK 21 C13 cell line growth and Aujeszky's disease virus (ADV) production. Growth kinetics of ...

  16. 21 CFR 1250.79 - Garbage disposal.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Garbage disposal. 1250.79 Section 1250.79 Food and... SANITATION Servicing Areas for Land and Air Conveyances § 1250.79 Garbage disposal. (a) Water-tight, readily cleanable, nonabsorbent containers with close-fitting covers shall be used to receive and store garbage. (b...

  17. 23 CFR 710.409 - Disposals.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Disposals. 710.409 Section 710.409 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY AND ENVIRONMENT RIGHT-OF-WAY AND REAL ESTATE Real Property Management § 710.409 Disposals. (a) Real property interests determined to be excess...

  18. Retrievable disposal - opposing views on ethics

    International Nuclear Information System (INIS)

    Selling, H.A.

    2000-01-01

    In the previous decades many research programmes on the disposal of radioactive waste have been completed in the Netherlands. The experts involved have reconfirmed their view that deep underground disposal in suitable geological formations would ensure a safe and prolonged isolation of the waste from the biosphere. Both rock salt and clay formations are considered to qualify as a suitable host rock. In 1993 the government in a position paper stated that such a repository should be designed in a way that the waste can be retrieved from it, should the need arise. In an attempt to involve stakeholders in the decision-making process, a research contract was awarded to an environmental group to study the ethical aspects related to retrievable disposal of radioactive waste. In their report which was published in its final form in January 2000 the authors concluded that retrievable disposal is acceptable from an ethical point of view. However, this conclusion was reached in the understanding that this situation of retrievability would be permanent. From the concept of equity between generations, each successive generation should be offered equal opportunities to decide for itself how to dispose of the radioactive waste. Consequently, the preferred disposal option is retrievable disposal (or long term storage) in a surface facility. Although this view is not in conformity with the ''official'' position on radioactive waste disposal, there is a benefit of having established a dialogue between interested parties in a broad sense. (author)

  19. Crystalline and Crystalline International Disposal Activities

    Energy Technology Data Exchange (ETDEWEB)

    Viswanathan, Hari S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chu, Shaoping [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Makedonska, Nataliia [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hyman, Jeffrey De' Haven [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Karra, Satish [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dittrich, Timothy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-21

    This report presents the results of work conducted between September 2014 and July 2015 at Los Alamos National Laboratory in the crystalline disposal and crystalline international disposal work packages of the Used Fuel Disposition Campaign (UFDC) for DOE-NE’s Fuel Cycle Research and Development program.

  20. The capacitated distribution and waste disposal problem

    NARCIS (Netherlands)

    J.M. Bloemhof-Ruwaard (Jacqueline); M. Salomon (Marc); L.N. van Wassenhove (Luk)

    1996-01-01

    textabstractWe study the problem of the simultaneous design of a distribution network with plants and waste disposal units, and the coordination of product flows and waste flows within this network. The objective is to minimize the sum of fixed costs for opening plants and waste disposal units, and

  1. Probabilistic safety assessment in radioactive waste disposal

    International Nuclear Information System (INIS)

    Robinson, P.C.

    1987-07-01

    Probabilistic safety assessment codes are now widely used in radioactive waste disposal assessments. This report gives an overview of the current state of the field. The relationship between the codes and the regulations covering radioactive waste disposal is discussed and the characteristics of current codes is described. The problems of verification and validation are considered. (author)

  2. Safety assessment for radiactive waste disposal

    International Nuclear Information System (INIS)

    Lewi, J.; Izabel, C.

    1989-11-01

    Whatever their type may be, radioactive waste disposals obey to the following principle: to isolate radioactive substances as long as their potential nocivity is significant. The isolation is obtained by confining barriers. The present paper recalls the role and the limits of the different barriers, for each type of disposal. It presents and comments site selection criteria and waste packages requirements [fr

  3. Disposable electrochemical DNA biosensor for environmental ...

    Indian Academy of Sciences (India)

    A simple procedure for the voltammetric detection of the DNA damage using a disposable electrochemical DNA biosensor is reported. The DNA biosensor is assembled by immobilizing the double stranded calf thymus DNA (dsDNA) on the surface of a disposable carbon screen-printed electrode. The interaction of ...

  4. Evaluation of waste disposal by shale fracturing

    International Nuclear Information System (INIS)

    Weeren, H.O.

    1976-02-01

    The shale fracturing process is evaluated as a means for permanent disposal of radioactive intermediate level liquid waste generated at the Oak Ridge National Laboratory. The estimated capital operating and development costs of a proposed disposal facility are compared with equivalent estimated costs for alternative methods of waste fixation

  5. 7 CFR 2902.21 - Disposable containers.

    Science.gov (United States)

    2010-01-01

    ... Items § 2902.21 Disposable containers. (a) Definition. Products designed to be used for temporary storage or transportation of materials including, but not limited to, food items. (b) Minimum biobased... paragraph (d): Disposable containers can include boxes and packaging made from paper. Under the Resource...

  6. 50 CFR 12.33 - Disposal.

    Science.gov (United States)

    2010-10-01

    ... other equipment), except wildlife or plants, in accordance with current Federal Property Management..., TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS SEIZURE AND FORFEITURE PROCEDURES Disposal of Forfeited or Abandoned Property § 12.33 Disposal. (a) The Director shall...

  7. Disposal of high-activity nuclear wastes

    International Nuclear Information System (INIS)

    Hamilton, E.I.

    1983-01-01

    A discussion is presented on the deep sea ocean disposal for high-activity nuclear wastes. The following topics are covered: effect of ionizing radiation on marine ecosystems; pathways by which radionuclides are transferred to man from the marine environment; information about releases of radioactivity to the sea; radiological protection; storage and disposal of radioactive wastes and information needs. (U.K.)

  8. A LARGE FOREIGN BODY IN THE TRACHEA (SEWING NEEDLE

    Directory of Open Access Journals (Sweden)

    P. D. Pryanikov

    2017-01-01

    Full Text Available The authors present a case study: an unusual foreign body (sewing needle in the trachea. Despite the large size and unusual shape of a foreign body, we managed to remove it through the airways with rigid upper traheobronchoscopy, avoiding complications.

  9. Atypical chest pain: Needles in a haystack | Jansen van Vuuren ...

    African Journals Online (AJOL)

    A 20-year-old man presented with a 6-month history of intermittent chest pain. Initial imaging demonstrated approximately 15 sewing needles lodged in his myocardium, predominantly in the left ventricle. The patient has been referred to cardiothoracic surgery for further management. His progress will be monitored closely.

  10. Metallic sewing needle ingestion presenting as acute abdomen ...

    African Journals Online (AJOL)

    We reported an unusual case of a 26‑year‑old man presenting to surgical emergency as generalized peritonitis following an ingestion of multiple metallic sewing needles. The X‑ray of his abdomen showed pneumoperitoneum and multiple metallic foreign bodies in the abdominal cavity. An ultrasonogram of his abdomen ...

  11. Antibacterial activity of endophytic fungi isolated from conifer needles

    African Journals Online (AJOL)

    Fungi, in particular endophytes are a promising source of new antimicrobial compounds. The aim of this study was to screen the extracts of conifer needle fungal endophytes for antimicrobial activity and taxonomically place fungi producing ones to determined active metabolites. Seventy three strains of endophytic fungi ...

  12. Multi hollow needle to plate plasmachemical reactor for pollutant decomposition

    International Nuclear Information System (INIS)

    Pekarek, S.; Kriha, V.; Viden, I.; Pospisil, M.

    2001-01-01

    Modification of the classical multipin to plate plasmachemical reactor for pollutant decomposition is proposed in this paper. In this modified reactor a mixture of air and pollutant flows through the needles, contrary to the classical reactor where a mixture of air and pollutant flows around the pins or through the channel plus through the hollow needles. We give the results of comparison of toluene decomposition efficiency for (a) a reactor with the main stream of a mixture through the channel around the needles and a small flow rate through the needles and (b) a modified reactor. It was found that for similar flow rates and similar energy deposition, the decomposition efficiency of toluene was increased more than six times in the modified reactor. This new modified reactor was also experimentally tested for the decomposition of volatile hydrocarbons from gasoline distillation range. An average efficiency of VOC decomposition of about 25% was reached. However, significant differences in the decomposition of various hydrocarbon types were observed. The best results were obtained for the decomposition of olefins (reaching 90%) and methyl-tert-butyl ether (about 50%). Moreover, the number of carbon atoms in the molecule affects the quality of VOC decomposition. (author)

  13. Histology of specimens taken by prostatectomy and needle biopsy ...

    African Journals Online (AJOL)

    Histology of specimens taken by prostatectomy and needle biopsy. P M Ngugi, B Byakika. Abstract. No Abstract. East African Medical Journal Vol. 84 (8) 2007: pp. 363-366. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  14. Mass analysis of an atmospheric pressure plasma needle discharge

    International Nuclear Information System (INIS)

    Malovic, G; Puac, N; Lazovic, S; Petrovic, Z

    2010-01-01

    Mass spectrometric measurements of a plasma needle (an example of atmospheric pressure non-equilibrium plasma source) were made for neutrals and ions. The measurements were performed for the same geometry as the standard plasma needles albeit for a somewhat increased gas flow. We discuss some of the problems of performing mass analysis at atmospheric pressures. The yields of N, O and NO radicals from the plasma needle were determined for different powers of the RF source and different flow rates of working gas. Positive ions generated by the plasma needle itself were measured for the first time. Significant conversion of feed gases (nitrogen and oxygen) into radicals and ions of N and O, and NO was observed as well as depletion of atomic radicals N and O which in chemical reactions form more complex molecules. Biomedical and nanotechnology applications of atmospheric pressure plasmas require a detailed understanding of the source, and mass analysis is perhaps the best technique to focus on chemical kinetics and in many ways interaction with surfaces.

  15. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity was 61.5% and specificity 89.5% . Conclusion: This study revealed high specificity and low sensitivity of Fine Needle Aspiration Cytology (FNAC) at detecting malignancy in thyroid nodules.

  16. Hepatitis B Vaccination Status and Needle stick Injuries among ...

    African Journals Online (AJOL)

    Background: Hepatits B virus (HBV) is the most common blood borne pathogen that poses an occupational risk to Health-care workers. The incidence of infection following needle stick injury has been reported to be high among medical students. Effective vaccines against HBV are available. The aim of this study was to ...

  17. Sensorimotor Learning of Acupuncture Needle Manipulation Using Visual Feedback.

    Directory of Open Access Journals (Sweden)

    Won-Mo Jung

    Full Text Available Humans can acquire a wide variety of motor skills using sensory feedback pertaining to discrepancies between intended and actual movements. Acupuncture needle manipulation involves sophisticated hand movements and represents a fundamental skill for acupuncturists. We investigated whether untrained students could improve their motor performance during acupuncture needle manipulation using visual feedback (VF.Twenty-one untrained medical students were included, randomly divided into concurrent (n = 10 and post-trial (n = 11 VF groups. Both groups were trained in simple lift/thrusting techniques during session 1, and in complicated lift/thrusting techniques in session 2 (eight training trials per session. We compared the motion patterns and error magnitudes of pre- and post-training tests.During motion pattern analysis, both the concurrent and post-trial VF groups exhibited greater improvements in motion patterns during the complicated lifting/thrusting session. In the magnitude error analysis, both groups also exhibited reduced error magnitudes during the simple lifting/thrusting session. For the training period, the concurrent VF group exhibited reduced error magnitudes across all training trials, whereas the post-trial VF group was characterized by greater error magnitudes during initial trials, which gradually reduced during later trials.Our findings suggest that novices can improve the sophisticated hand movements required for acupuncture needle manipulation using sensorimotor learning with VF. Use of two types of VF can be beneficial for untrained students in terms of learning how to manipulate acupuncture needles, using either automatic or cognitive processes.

  18. Main flavonoids in needles of Larix decidu A

    NARCIS (Netherlands)

    Niemann, Gerard J.

    Present work. Freeze-dried needles were extracted with acetone-water. Ether and butanol fractions were separated by repeated banding on paper. Nine major flavonoids were isolated (in solution) and identified by chromatographic and UV spectral data of both the original and alkaline and/or acid

  19. Fine Needle Aspiration: A simple and convenient alternative for ...

    African Journals Online (AJOL)

    Nine patients followed up to hospital for other medical problems unrelated to ganglion cysts and only one patient had to undergo surgical excision due to the large size of the cyst. No patient returned with a recurrence. Conclusion: Fine needle aspiration is a simple, non traumatic, inexpensive and low risk alternative method ...

  20. Atom sharp needles, the missing link in microneedle drug delivery

    NARCIS (Netherlands)

    Wissink, J.; Berenschot, Johan W.; Tas, Niels Roelof

    2008-01-01

    The skin barrier function is a major challenge for delivery of drugs via the skin. Located in the outermost layer of the skin, the stratum corneum (SC) consists of dead cells embedded in lipid regions, only 10-20 microm thick, tough but flexible and elastic. Hyperdermic needles penetrate the skin

  1. Mountain Norway spruce forests: Needle supply and its nutrient content

    Czech Academy of Sciences Publication Activity Database

    Kovářová, Marcela; Vacek, S.

    2003-01-01

    Roč. 49, - (2003), s. 327-332 ISSN 1212-4834 R&D Projects: GA AV ČR KSK6005114; GA ČR GA206/99/1416 Institutional research plan: CEZ:AV0Z6005908 Keywords : Šumava Mts. * Mountain Norway spruce forest * needle mass Subject RIV: EF - Botanics

  2. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  3. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    Background: The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound‑guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those ...

  4. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    2011-06-11

    Jun 11, 2011 ... Acheson MB, Patton RG, Howisey RL, Lane RF, Morgan A, Rowbotham RK. Three‑ to six‑year followup for 379 benign image‑guided large‑core needle biopsies of nonpalpable breast abnormalities. J Am Coll Surg 2002;195:462‑6. 8. Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S. Accuracy.

  5. Knowledge and experiences of needle prick injuries (NPI) among ...

    African Journals Online (AJOL)

    Nursing students on training are no exception, as they get exposed to acciden- tal needle pricks and contamination during their hospital activities. Lack of appropriate resources, knowledge and skills, coupled with the unavailability of the universal standard precautionary procedures and compliance thereof, constitute high ...

  6. Fine Needle Aspiration Cytology [FNAC] Technique As A Diagnostic ...

    African Journals Online (AJOL)

    Background: The Fine needle aspiration technique is frequently done in the University of Maiduguri Teaching Hospital for swellings from any anatomical site of the body. Objective: This paper is aimed at highlighting the importance of the technique in the diagnosis of tumours in any health care institution. Methods: A ...

  7. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Background: Thyroid disease affects about 5% of the World's population. Fine Needle Aspiration Cytology (FNAC) helps in planning extent of surgery. In some studies, FNAC has been found to have a low accuracy for malignancy. Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for ...

  8. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    Objective: To determine the histopathologic correlation of fine needle aspiration cytology FNAC of breast masses seen in the department of histopathology of the Federal Medical Center Owo, Southwestern Nigeria. Design: This is a 5-year retrospective study of breast lumps seen at Department of Histopathology, Federal ...

  9. Comparing Aspiration and Non-aspiration Fine Needle Techniques ...

    African Journals Online (AJOL)

    Background: Nodular goitre remains a problem of enormous magnitude with an estimated prevalence of 19 to 35% worldwide. Of all thyroid nodules 5-10% are cancerous and require surgery. By identifying the benign ones unnecessary surgery, the associated morbidity and associated costs could be avoided. Fine needle ...

  10. Facile method to align crystalline needles composed of organic ...

    Indian Academy of Sciences (India)

    2017-09-23

    Sep 23, 2017 ... because of their potential applications to devices such as field-effect transistors. Although dip coating ... were precipitated. The thicknesses and lengths of the crystalline needles were controlled by the composition of the solvent .... An HMDS-treated glass slide, on which a PDMS block was obliquely placed ...

  11. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  12. A Cross Section Study to Correlate Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    ADMIN

    Background: Needle Aspiration Cytology (FNAC) is cheap, simple, quick, minimally invasive procedure that is widely used for preoperative diagnosis of Parotid tumours. Methods: Twenty five patients were prospectively studied over a two-year period at four major hospitals in Zambia. FNAC was done using a 10cc syringe ...

  13. Prevalence of needle stick injuries among healthcare workers at the ...

    African Journals Online (AJOL)

    Healthcare workers (HCW) can easily contact infections with blood-borne pathogens such infections are hepatitis B virus (HBV), hepatitis C virus (HCV) and human immunodeficiency virus (HIV), when health workers are exposed to occupational blood diseases through the use of sharp instruments and needle sticks.

  14. Pressure on the conical surface of needle valves

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2014-01-01

    Roč. 220, č. 1 (2014), s. 1-12 ISSN 0924-4247 R&D Projects: GA ČR GA13-23046S Institutional support: RVO:61388998 Keywords : nozzle * needle nozzle * flow separation Subject RIV: BK - Fluid Dynamics Impact factor: 1.903, year: 2014 http://www.sciencedirect.com/science/article/pii/S0924424714004087

  15. SKINNY – SKIN thickness and Needles in the Young | Marran ...

    African Journals Online (AJOL)

    Inappropriate insulin injection technique, inadvertent intramuscular (IM) injections, needle phobia and insulin omission negatively affect glucose control. Objectives. To document skin and skin plus subcutaneous skin thickness using high resolution ultrasound (US) in a group of children and adolescents with type 1 diabetes.

  16. Prevalence of needle stick injuries among healthcare workers

    African Journals Online (AJOL)

    Abe Olugbenga

    ABSTRACT. Background:A needle-stick is a sharp-pointed instrument used for puncturing tissues or passing a ligature around or through a vessel, but possibly also it could be a sharp instruments or objects for other purposes. Healthcare workers (HCW) can easily contact infections with blood-borne pathogens such ...

  17. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  18. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    E-mail: tunjiomotayo@yahoo.co.uk. Conflict of interest: None declared. SUMMARY. Objective: To determine the histopathologic correlation of fine needle aspiration cytology FNAC of breast masses seen in the department of histopathology of the Federal Medical Center Owo, Southwestern Nigeria. Design: This is a 5-year ...

  19. Need for needle and syringe programmes in Africa | Derrick | African ...

    African Journals Online (AJOL)

    A narrative review was conducted, drawing on peer reviewed literature and relevant grey literature on injecting drug use in African countries and ethical dilemmas facing harm reduction especially the provision of sterile needles and syringes to injecting drug users. This review aimed at highlighting evidence and the ...

  20. Emerging Needle Blight Diseases in Atlantic Pinus Ecosystems of Spain

    Directory of Open Access Journals (Sweden)

    Esther Ortíz de Urbina

    2016-12-01

    Full Text Available Red band needle blight caused by Dothistroma septosporum and D. pini, and brown spot needle blight caused by Lecanosticta acicola provoke severe and premature defoliation in Pinus, and subsequent reduction of photosynthetic surfaces, vitality, and growth in young and adult trees. The recurrent damage results in branch and tree death. Until recently, pine needle blight diseases have had only minor impacts on native and exotic forest trees in the North of Spain, but in the past five years, these pathogen species have spread widely and caused severe defoliation and mortality in exotic and native plantations of Pinus in locations where they were not detected before. In an attempt to understand the main causes of this outbreak and to define the effectiveness of owners’ management strategies, four research actions were implemented: a survey of the management activities implemented by the owners to reduce disease impact, the evaluation of specific symptoms and damage associated with infection, and the identification of the causative pathogenic species and their reproductive capacity. Morphological characteristics of the fungus and molecular identification were consistent with those of Lecanosticta acicola and Dothistroma spp., D. septosporum, D. Pini, and both mating types were present for the three identified pathogens. The local silvicultural management performed, mainly pruning and thinning, was not resulting in the expected improvement. The results of this study can be applied to establish guidelines for monitoring and controlling the spread of needle blight pathogens.

  1. Efficacy of Fine Needle Aspiration Cytology in the Diagnosis of ...

    African Journals Online (AJOL)

    Background: Fine needle aspiration cytology (FNAC) is a safe, easy to perform, cost effective and an accurate procedure used in the diagnosis of thyroid lesions. Objective: In this study we aimed to demonstrate the effectiveness of FNAC in the diagnosis of thyroid swellings in Red Sea State, Sudan. Methods: FNAC from ...

  2. Fine-needle aspiration biopsy of lymph nodes

    African Journals Online (AJOL)

    2012-02-02

    Feb 2, 2012 ... FNAB is minimally painful when performed correctly. The exceptions would be placing the needle in the SCM muscle, brachial plexus, and inflamed salivary glands. Molecular genetic studies. Both the polymerase chain reaction (PCR) and fluorescence in situ hybridisation (FISH) identify tiny regions of DNA ...

  3. The Single Needle Lockstitch Machine. [Setting a Collar.] Module 5.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on sewing collars, one in a series on the single needle lockstitch sewing machine for student self-study, contains three sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  4. The Single Needle Lockstitch Machine. [Setting Zippers.] Module 8.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on setting zippers, one in a series on the single needle lockstitch sewing machine for student self-study, contains five sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  5. The Single Needle Lockstitch Machine. [Sewing Seams.] Module 4.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on sewing seams, one in a series on the single needle lockstitch sewing machine for student self-study, contains three sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  6. The Single Needle Lockstitch Machine. [Constructing Darts.] Module 3.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on constructing darts, one in a series on the single needle lockstitch sewing machine for student self-study, contains two sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  7. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  8. Morphea on the Breast after a Needle Biopsy

    OpenAIRE

    Arase, Noriko; Igawa, Ken; Senda, Satoko; Terao, Mika; Murota, Hiroyuki; Katayama, Ichiro

    2011-01-01

    Localized scleroderma (morphea) usually develops spontaneously, but the precise mechanisms underlying disease development are obscure. However, a significant number of cases suggest that morphea is induced by external stimuli. Herein, we report a case of morphea that developed after a needle biopsy.

  9. Competition of Scleroconidioma sphagnicola with fungi decomposing spruce litter needles

    Czech Academy of Sciences Publication Activity Database

    Koukol, Ondřej; Mrnka, Libor; Kulhánková, A.; Vosátka, Miroslav

    2006-01-01

    Roč. 84, - (2006), s. 469-476 ISSN 0008-4026 R&D Projects: GA ČR(CZ) GA206/05/0269 Institutional research plan: CEZ:AV0Z60050516 Keywords : litter needles * competition * agar pairing Subject RIV: EF - Botanics Impact factor: 1.193, year: 2006

  10. Needle parameter variation of mature black spruce families displaying a genetic x environment interaction in growth

    Science.gov (United States)

    John E. Major; Kurt H. Johnsen; Debby C. Barsi; Moira Campbell

    2013-01-01

    To examine soil moisture stress, light, and genetic effects on individual needle parameters and investigate total needle contribution to productivity, individual and total needle parameter variation were quantified in 32-year-old black spruce from five crown positions from four full-sib families studied previously for drought tolerance and differential productivity on...

  11. Mechanics-Based Model for Predicting In-Plane Needle Deflection with Multiple Bends

    NARCIS (Netherlands)

    Roesthuis, Roy; Abayazid, Momen; Misra, Sarthak

    2012-01-01

    Bevel-tipped flexible needles naturally bend when inserted into soft tissue. Steering such needles along curved paths allows one to avoid anatomical obstacles and reach locations inside the human body which are unreachable with rigid needles. In this study, a mechanics-based model is presented which

  12. EUS Needle Identification Comparison and Evaluation study (with videos)

    DEFF Research Database (Denmark)

    Tang, Shou-Jiang; Vilmann, Andreas Slot; Saftoiu, Adrian

    2016-01-01

    BACKGROUND AND AIMS: EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to rev...

  13. Terpenoid resin distribution in conifer needles with implications for red tree vole, Arborimus longicaudus, foraging

    Science.gov (United States)

    Rick G. Kelsey; Eric D. Forsman; James K. Swingle

    2009-01-01

    Tree voles are dietary specialists, feeding almost exclusively on conifer needles and bark. They reduce their exposure to conifer chemical defenses by physically removing resin ducts from many needles before ingesting the remaining tissue. The portion of needle removed differs among tree species, depending on the location of the resin ducts. To evaluate the amount of...

  14. Comparison of the Diagnostic Yield of EUS Needles for Liver Biopsy: Ex Vivo Study.

    Science.gov (United States)

    Lee, Woo Jung; Uradomo, Lance T; Zhang, Yang; Twaddell, William; Darwin, Peter

    2017-01-01

    EUS-guided liver biopsy is an emerging method of liver tissue acquisition which is safe and had been shown to produce excellent histological yield. There is limited data comparing the diagnostic yield of different FNA needles. We aimed to compare the diagnostic performance of four commercially available 19-gauge FNA needles. Four FNA needles and one percutaneous needle were used to perform liver biopsies on two human cadaveric livers: Cook Echotip Procore™, Olympus EZ Shot 2™, Boston Scientific Expect Slimline™, Covidien SharkCore™, and an 18-gauge percutaneous needle (TruCore™, Argon Medical Devices). Each needle obtained biopsies by three, six, and nine complete back-and-forth motions of the needle ("throw") with a fanning technique. The combined lengths of specimen fragments and the total number of complete portal tracts (CPT) were measured by a blinded pathologist. One-way analysis of variance (ANOVA) and Bonferroni correction were used for statistical analysis. A total of 52 liver biopsies were performed. The Covidien SharkCore needle had significantly greater number of CPT compared to other FNA needles. The number of "throws" did not impact the number of CPT significantly. There was no statistically significant difference in mean total specimen length between each FNA needle type. The Covidien SharkCore needle produced superior histological specimen by capturing more CPT, possibly due to its unique needle design.

  15. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  16. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  17. Deep Borehole Disposal as an Alternative Concept to Deep Geological Disposal

    International Nuclear Information System (INIS)

    Lee, Jongyoul; Lee, Minsoo; Choi, Heuijoo; Kim, Kyungsu

    2016-01-01

    In this paper, the general concept and key technologies for deep borehole disposal of spent fuels or HLW, as an alternative method to the mined geological disposal method, were reviewed. After then an analysis on the distance between boreholes for the disposal of HLW was carried out. Based on the results, a disposal area were calculated approximately and compared with that of mined geological disposal. These results will be used as an input for the analyses of applicability for DBD in Korea. The disposal safety of this system has been demonstrated with underground research laboratory and some advanced countries such as Finland and Sweden are implementing their disposal project on commercial stage. However, if the spent fuels or the high-level radioactive wastes can be disposed of in the depth of 3-5 km and more stable rock formation, it has several advantages. Therefore, as an alternative disposal concept to the mined deep geological disposal concept (DGD), very deep borehole disposal (DBD) technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, the general concept of deep borehole disposal for spent fuels or high level radioactive wastes was reviewed. And the key technologies, such as drilling technology of large diameter borehole, packaging and emplacement technology, sealing technology and performance/safety analyses technologies, and their challenges in development of deep borehole disposal system were analyzed. Also, very preliminary deep borehole disposal concept including disposal canister concept was developed according to the nuclear environment in Korea

  18. Deep Borehole Disposal as an Alternative Concept to Deep Geological Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jongyoul; Lee, Minsoo; Choi, Heuijoo; Kim, Kyungsu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, the general concept and key technologies for deep borehole disposal of spent fuels or HLW, as an alternative method to the mined geological disposal method, were reviewed. After then an analysis on the distance between boreholes for the disposal of HLW was carried out. Based on the results, a disposal area were calculated approximately and compared with that of mined geological disposal. These results will be used as an input for the analyses of applicability for DBD in Korea. The disposal safety of this system has been demonstrated with underground research laboratory and some advanced countries such as Finland and Sweden are implementing their disposal project on commercial stage. However, if the spent fuels or the high-level radioactive wastes can be disposed of in the depth of 3-5 km and more stable rock formation, it has several advantages. Therefore, as an alternative disposal concept to the mined deep geological disposal concept (DGD), very deep borehole disposal (DBD) technology is under consideration in number of countries in terms of its outstanding safety and cost effectiveness. In this paper, the general concept of deep borehole disposal for spent fuels or high level radioactive wastes was reviewed. And the key technologies, such as drilling technology of large diameter borehole, packaging and emplacement technology, sealing technology and performance/safety analyses technologies, and their challenges in development of deep borehole disposal system were analyzed. Also, very preliminary deep borehole disposal concept including disposal canister concept was developed according to the nuclear environment in Korea.

  19. Recent activity on disposal of uranium waste

    International Nuclear Information System (INIS)

    Fujiwara, Noboru

    1999-01-01

    The concept on the disposal of uranium waste has not been discussed in the Atomic Energy Commission of Japan, but the research and development of it are carried out in the company and agency which are related to uranium waste. In this paper, the present condition and problems on disposal of uranium waste were shown in aspect of the nuclear fuel manufacturing companies' activity. As main contents, the past circumstances on the disposal of uranium waste, the past activity of nuclear fuel manufacturing companies, outline and properties of uranium waste were shown, and ideas of nuclear fuel manufacturing companies on the disposal of uranium waste were reported with disposal idea in the long-term program for development and utilization of nuclear energy. (author)

  20. Revised user's guide to the 'DISPOSALS' model

    International Nuclear Information System (INIS)

    Laundy, R.S.; James, A.R.; Groom, M.S.; LeJeune, S.R.

    1985-04-01

    This report provides a User's Guide to the 'DISPOSALS' computer model and includes instructions on how to set up and run a specific problem together with details of the scope, theoretical basis, data requirements and capabilities of the model. The function of the 'DISPOSALS' model is to make assignments of nuclear waste material in an optimum manner to a number of disposal sites each subject to a number of constraints such as limits on the volume and activity. The user is able to vary the number of disposal sites, the range and limits of the constraints to be applied to each disposal site and the objective function for optimisation. The model is based on the Linear Programming technique and uses CAP Scientific's LAMPS and MAGIC packages. Currently the model has been implemented on CAP Scientific's VAX 11/750 minicomputer. (author)

  1. User's guide to the 'DISPOSALS' model

    International Nuclear Information System (INIS)

    Groom, M.S.; James, A.R.; Laundy, R.S.

    1984-03-01

    This report provides a User's Guide to the 'DISPOSALS' computer model and includes instructions on how to set up and run a specific problem together with details of the scope, theoretical basis, data requirements and capabilities of the model. The function of the 'DISPOSALS' model is to make assignments of nuclear waste material in an optimum manner to a number of disposal sites each subject to a number of constraints such as limits on the volume and activity. The user is able to vary the number of disposal sites, the range and limits of the constraints to be applied to each disposal site and the objective function for optimisation. The model is based on the Linear Programming technique and uses CAP Scientific's LAMPS and MAGIC packages. Currently the model has been implemented on CAP Scientific's VAX 11/750 minicomputer. (author)

  2. Radioactive waste disposal in W.A

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1983-01-01

    Radioactive waste in Western Australia arises primarily from medical diagnosis and treatment and from scientific research mainly with a medical orientation. Waste is classified before disposal depending on its level and type of radioactivity and then disposed of either to municipal land fill sites, to the sewerage system or by incineration. The amounts of radioactive materials which may be disposed of to the sewers and air are set by the Radiation Safety Act (1975) Regulations, and the land fill operations are controlled to ensure isolation of the material. Other waste such as unwanted sources used in industrial applications are stored for future disposal. Discussions are being held between officers of the State and Australian Governments aimed at providing suitable disposal methods for sources of this kind

  3. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  4. Occurrence and knowledge about needle stick injury in nursing students

    International Nuclear Information System (INIS)

    Prasuna, J.; Sharma, R.

    2015-01-01

    Needle stick injury (NSI) became a major issue and most of the research focuses on Nurses, Doctors and other health care workers, but at the same time nursing students in clinical duties are at high risk. Studies are available which examined NSI only in Medical students and health care workers. The present study is aimed to measure the occurrence of needle stick injury along with post exposure measures and evaluation of the knowledge regarding needle stick injury among nursing student. Methods: A cross-sectional study was conducted in North-East India in 2013. The study participants comprised of 83 nursing students studying in 4th year B.Sc. (N) and 3rd year General Nursing and Midwifery (GNM). Students were questioned regarding their occurrence to Needle Stick Injury throughout their clinical training and measures taken following the exposure. They were also asked to complete the Knowledge questionnaire on NSI. Results: The study among 83 nursing students included 43 (51.81%) GNM 3rd year and 40 (48.19%) B.Sc. Nursing Students. Out of a total 83 students, 75 (90.36%) were females. The occurrence of NSI during their course was reported by 33 (39.76%) participants. The maximum NSI occurred during first year of course (57.57%). It was found that 18 (54.54%) of NSIs were not reported. Among those exposed, only 5 (15.15%) students had undergone blood investigation and very few students took post exposure measures. It was found that, only 23 (69.69%) students were immunized against Hepatitis B before NSI. Conclusion: The present study indicated a high incidence of needle stick injuries among nursing students with more under-reported cases and subjects were not aware of post exposure measures. It is essential to deal above problems by regular training on real-life procedure at the entry level and reporting system should be more user-friendly platform. (author)

  5. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine-needle...

  6. Transport and nuclear waste disposal

    International Nuclear Information System (INIS)

    Wild, E.

    1999-01-01

    The author assesses both past and future of nuclear waste disposal in Germany. The failure of the disposal concept is, he believes, mainly the fault of the Federal Government. On the basis of the Nuclear Energy Act, the government is obliged to ensure that ultimate-storage sites are established and operated. Up to the present, however, the government has failed - apart from the episode in Asse and Morsleben and espite existing feasible proposals in Konrad and Gorleben - to achieve this objective. This negative development is particularly evident from the projects which have had to be prematurely abandoned. The costs of such 'investment follies' meanwhile amount to several billion DM. At least 92% of the capacity in the intermediate-storage sites are at present unused. Following the closure of the ultimate-storage site in Morsleben, action must be taken to change over to long-term intermediate-storage of operational waste. The government has extensive intermediate-storage capacity at the intermediate-storage site Nord in Greifswald. There, the wate originally planned for storage in Morsleben could be intermediately stored at ERAM-rates. Nuclear waste transportation, too, could long ago have been resumed, in the author's view. For the purpose of improving the transport organisation, a new company was founded which represents exclusively the interests of the reprocessing firms at the nuclear power stations. The author's conclusion: The EVU have done their homework properly and implemented all necessary measures in order to be able to resume transport of fuel elements as soon as possible. The generating station operators favour a solution based upon agreement with the Federal Government. The EVU have already declared their willingness - in the event of unanimous agreement - to set up intermediate-storage sites near the power stations. The ponds in the generating stations, however, are unsuitable for use as intermediate-storage areas. If intermediate-storage areas for

  7. Needle tract implantation after fine needle aspiration biopsy (FNAB) of transitional cell carcinoma of the urinary bladder and adenocarcinoma of the lung.

    Science.gov (United States)

    Vignoli, M; Rossi, F; Chierici, C; Terragni, R; De Lorenzi, D; Stanga, M; Olivero, D

    2007-07-01

    This paper reports three clinical cases of needle tract implantation of neoplastic cells on the abdominal and thoracic wall after ultrasound (US) fine needle aspiration biopsy (FNAB). Primary tumors were two transitional cell carcinomas of the urinary bladder (2 dogs) and one pulmonary adenocarcinoma (1 cat). All three masses grew up along the needle tract. To our knowledge, the seeding of pulmonary adenocarcinoma cells after FNAB on the thoracic wall has never been reported in veterinary medicine.

  8. Clogging in staked-in needle pre-filled syringes (SIN-PFS): Influence of water vapor transmission through the needle shield.

    Science.gov (United States)

    De Bardi, M; Müller, R; Grünzweig, C; Mannes, D; Rigollet, M; Bamberg, F; Jung, T A; Yang, K

    2018-02-12

    Staked-in needle pre-fillable syringes (SIN-PFS) are a convenient delivery system widely established in the growing pharmaceutical market. Under specific storage conditions, the needle of PFS containing high concentration drug product (DP) solution is prone to clogging, which prevents administration of the liquid. The purpose of this study is to clarify the clogging phenomenon of SIN-PFS and to elucidate the role of water vapor transmission via the needle shield. The presence of liquid within needles is a prerequisite condition for clogging and was investigated non-invasively by neutron imaging (NI) to confirm that liquid can migrate into the needle under certain processing conditions. The water vapor transmission rate (WVTR) of different needle shields was measured and the impact of temperature and relative humidity (rH) on the WVTR was investigated on sheets with the same composition as used in commercial needle shields. Our study clearly showed that the partial vapor pressure difference (ΔPP) across the needle shield is the dominant driving factor for water vapor transmission. A linear correlation between ΔPP and WVTR was found and a model to predict the water vapor transmission for PFS under specific storage conditions was developed. The impact of the WVTR on needle clogging was confirmed by clogging tests performed on SIN-PFS stored under different conditions. Thereby, we clearly show that high water loss induced by higher WVTR can be correlated to an increased occurrence of needle clogging. In conclusion, the WVTR of the needle shield plays a key role in needle clogging and the established WVTR model can be employed to assess the clogging risk for product development. Copyright © 2018. Published by Elsevier B.V.

  9. Randomized clinical trial to assess pain and bruising in medicines administered by means of subcutaneous and intramuscular needle injection: Is it necessary to have needles changed?

    OpenAIRE

    Lamblet, Luiz Carlos Ribeiro; Meira, Edilson Sant'Anna; Torres, Silvana; Ferreira, Barbara Carvalho; Martucchi, Sergio Dias

    2011-01-01

    This clinical trial aimed at comparing the intensity of pain and bruising by subcutaneous and intramuscular injections using and retractable fixed syringes and needles and syringes with no needles combined, at a public hospital in Sao Paulo, for six months. We evaluated the perception of pain in case of intramuscular (n=1000) and subcutaneous injections (n=240). In subcutaneous application, bruise formation was also verified. Pain and bruising scores were higher in the group with no needles c...

  10. Disposal configuration options for future uses of greater confinement disposal at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Price, L. [Science Applications International Corp., Albuquerque, NM (United States)

    1994-09-01

    The US Department of Energy (DOE) is responsible for disposing of a variety of radioactive and mixed wastes, some of which are considered special-case waste because they do not currently have a clear disposal option. The DOE`s Nevada Field Office contracted with Sandia National Laboratories to investigate the possibility of disposing of some of this special-case waste at the Nevada Test Site (NTS). As part of this investigation, a review of a near-surface and subsurface disposal options that was performed to develop alternative disposal configurations for special-case waste disposal at the NTS. The criteria for the review included (1) configurations appropriate for disposal at the NTS; (2) configurations for disposal of waste at least 100 ft below the ground surface; (3) configurations for which equipment and technology currently exist; and (4) configurations that meet the special requirements imposed by the nature of special-case waste. Four options for subsurface disposal of special-case waste are proposed: mined consolidated rock, mined alluvium, deep pits or trenches, and deep boreholes. Six different methods for near-surface disposal are also presented: earth-covered tumuli, above-grade concrete structures, trenches, below-grade concrete structures, shallow boreholes, and hydrofracture. Greater confinement disposal (GCD) in boreholes at least 100 ft deep, similar to that currently practiced at the GCD facility at the Area 5 Radioactive Waste Management Site at the NTS, was retained as the option that met the criteria for the review. Four borehole disposal configurations are proposed with engineered barriers that range from the native alluvium to a combination of gravel and concrete. The configurations identified will be used for system analysis that will be performed to determine the disposal configurations and wastes that may be suitable candidates for disposal of special-case wastes at the NTS.

  11. Evaluation of 8.0-cm needle at the fourth anterior axillary line for needle chest decompression of tension pneumothorax.

    Science.gov (United States)

    Chang, Samuel J; Ross, Samuel Wade; Kiefer, David J; Anderson, William E; Rogers, Amelia T; Sing, Ronald F; Callaway, David W

    2014-04-01

    Five-centimeter needles at the second intercostal space midclavicular line (2MCL) have high failure rates for decompression of tension pneumothorax. This study evaluates 8-cm needles directed at the fourth intercostal space anterior axillary line (4AAL). Retrospective radiographic analysis of 100 consecutive trauma patients 18 years or older from January to September 2011. Measurements of chest wall thickness (CWT) and depth to vital structure (DVS) were obtained at 2MCL and 4AAL. 4AAL measurements were taken based on two angles: closest vital structure and perpendicular to the chest wall. Primary outcome measures were radiographic decompression (RD) (defined as CWT RNI) (DVS > 80 mm) of 8-cm needles at 4AAL. Secondary outcome measures are effect of angle of entry on RNI at 4AAL, RD and RNI of 8-cm needles at 2MCL, and comparison of 5-cm needles with 8-cm needles at both locations. Eighty-four percent of the patients were male, with mean Injury Severity Score (ISS) of 17.7 (range, 1.0-66.0) and body mass index of 26.8 (16.5-48.4). Mean CWT at 4AAL ranged from 37.6 mm to 39.9 mm, significantly thinner than mean CWT at 2MCL (43.3-46.7 mm). Eight-centimeter needle RD was more than 96% at both 4AAL and 2MCL. Five-centimeter RD ranged from 66% to 81% at all sites. Mean DVS at 4AAL ranged from 91.8 mm to 128.0 mm. RNI at all sites was more than 91% except at left 4AAL, when taken to the closest vital structure (mean DVS, 91.8 mm), with 68% RNI. Perpendicular entry increased DVS to 109.4 mm and subsequent RNI to 91%. Five-centimeter RNI at all sites was more than 99%. CWT at 4AAL is significantly thinner than 2MCL. Based on radiographic measurements, 8-cm catheters have a higher chance of pleural decompression when compared with 5-cm catheters. Steeper angle of entry at 4AAL improves 8-cm noninjury rates to more than 91%. Therapeutic/care management study, level IV.

  12. Numerical Modelling of Mutual Effect among Nearby Needles in a Multi-Needle Configuration of an Atmospheric Air Dielectric Barrier Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2012-05-01

    Full Text Available A numerical study has been conducted to understand the mutual effect among nearby needles in a multi-needle electrode dielectric barrier discharge. In the present paper, a fluid-hydrodynamic model is adopted. In this model, the mutual effect among nearby needles in a multi-needle configuration of an atmospheric air dielectric barrier discharge are investigated using a fluid-hydrodynamic model including the continuity equations for electrons and positive and negative ions coupled with Poisson’s equation. The electric fields at the streamer head of the middle needle (MN and the side needles (SNs in a three-needle model decreased under the influence of the mutual effects of nearby needles compared with that in the single-needle model. In addition, from the same comparison, the average propagation velocities of the streamers from MN and SNs, the electron average energy profile of MN and SNs (including those in the streamer channel, at the streamer head, and in the unbridged gap, and the electron densities at the streamer head of the MN and SNs also decreased. The results obtained in the current paper agreed well with the experimental and simulation results in the literature.

  13. Effects of irrigation, fertilization and drought on the occurrence of Lophodermium piceae in Picea abies needles

    Energy Technology Data Exchange (ETDEWEB)

    Lehtijaervi, Asko; Barklund, Pia [Swedish Univ. of Agricultural Sciences, Uppsala (Sweden). Dept. of Forest Mycology and Pathology

    1999-08-01

    Effects of irrigation, drought and fertilization on the frequency of the fungal endophyte Lophodermium piceae in green needles was assessed in a 30-year-old experimental stand of Picea abies in southern Sweden. Frequencies of needles with L. piceae were lower in irrigation and ammonium sulphate fertilization treatments than in the control. Drought treatment frequencies were similar to the control. Needles were susceptible to colonization for at least 3 years; colonization increased with needle age. The results indicate that the increased availability of water to the root system as well as ammonium sulphate fertilization indirectly delays colonization of needles by L. piceae 21 refs, 3 figs, 2 tabs

  14. Inserting needles into the body: a meta-analysis of brain activity associated with acupuncture needle stimulation.

    Science.gov (United States)

    Chae, Younbyoung; Chang, Dong-Seon; Lee, Soon-Ho; Jung, Won-Mo; Lee, In-Seon; Jackson, Stephen; Kong, Jian; Lee, Hyangsook; Park, Hi-Joon; Lee, Hyejung; Wallraven, Christian

    2013-03-01

    Acupuncture is a therapeutic treatment that is defined as the insertion of needles into the body at specific points (ie, acupoints). Advances in functional neuroimaging have made it possible to study brain responses to acupuncture; however, previous studies have mainly concentrated on acupoint specificity. We wanted to focus on the functional brain responses that occur because of needle insertion into the body. An activation likelihood estimation meta-analysis was carried out to investigate common characteristics of brain responses to acupuncture needle stimulation compared to tactile stimulation. A total of 28 functional magnetic resonance imaging studies, which consisted of 51 acupuncture and 10 tactile stimulation experiments, were selected for the meta-analysis. Following acupuncture needle stimulation, activation in the sensorimotor cortical network, including the insula, thalamus, anterior cingulate cortex, and primary and secondary somatosensory cortices, and deactivation in the limbic-paralimbic neocortical network, including the medial prefrontal cortex, caudate, amygdala, posterior cingulate cortex, and parahippocampus, were detected and assessed. Following control tactile stimulation, weaker patterns of brain responses were detected in areas similar to those stated above. The activation and deactivation patterns following acupuncture stimulation suggest that the hemodynamic responses in the brain simultaneously reflect the sensory, cognitive, and affective dimensions of pain. This article facilitates a better understanding of acupuncture needle stimulation and its effects on specific activity changes in different brain regions as well as its relationship to the multiple dimensions of pain. Future studies can build on this meta-analysis and will help to elucidate the clinically relevant therapeutic effects of acupuncture. Copyright © 2013 American Pain Society. All rights reserved.

  15. Dukovany radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Horyna, J.

    1998-01-01

    The most significant source of radioactive wastes in the Czech Republic is the operation of nuclear power plant. The original NPP design included only storage of concentrates and unsorted solid wastes in the nuclear power plant. Our concept of waste management from nuclear power plant operation has been gradually developed and it consists of solidification of radioactive concentrates, volume reduction of solid wastes by compressing and disposal of conditioned wastes in surface concrete vaults. The most significant part of the arising waste was assumed to be evaporator concentrates. in the design of the NPP it has been assumed that up to 1% of fuel element cladding may fail. With a sufficient number of natural and man-made barriers, the release of radioactive material will be limited and delayed, its migration retarded and its concentration sufficiently diluted to assure that the impact will remain in prescribed levels. Initial site selection studies started in the later seventies taking into account social, economic conditions and requirements for the protection of nature. After performed area surveys, the site near the constructed NPP Dukovany has been chosen. Safety assessment of Dukovany repository has been based on 3 critical scenarios: -groundwater transport to the nearest water supply, -Intrusion after end of institutional control, -dwelling on the site after end of institutional control. Compartment models based on the scenarios described above were formulated to estimate committed effective equivalent dose due to different exposure ways. (author)

  16. Method of disposing radioactive wastes

    International Nuclear Information System (INIS)

    Isozaki, Kei.

    1983-01-01

    Purpose : To enable safety ocean disposal of radioactive wastes by decreasing the leaching rate of radioactive nucleides, improving the quick-curing nature and increasing the durability. Method : A mixture comprising 2 - 20 parts by weight of alkali metal hydroxide and 100 parts by weight of finely powdered aqueous slags from a blast furnace is added to radioactive wastes to solidify them. In the case of medium or low level radioactive wastes, the solidification agent is added by 200 parts by weight to 100 parts by weight of the wastes and, in the case of high level wastes, the solidification agent is added in such an amount that the wastes occupy about 20% by weight in the total of the wastes and the solidification agent. Sodium hydroxide used as the alkali metal hydroxide is partially replaced with sodium carbonate, a water-reducing agent such as lignin sulfonate is added to improve the fluidity and suppress the leaching rate and the wastes are solidified in a drum can. In this way, corrosions of the vessel can be suppressed by the alkaline nature and the compression strength, heat stability and the like of the product also become excellent. (Sekiya, K.)

  17. Inspection of disposal canisters components

    International Nuclear Information System (INIS)

    Pitkaenen, J.

    2013-12-01

    This report presents the inspection techniques of disposal canister components. Manufacturing methods and a description of the defects related to different manufacturing methods are described briefly. The defect types form a basis for the design of non-destructive testing because the defect types, which occur in the inspected components, affect to choice of inspection methods. The canister components are to nodular cast iron insert, steel lid, lid screw, metal gasket, copper tube with integrated or separate bottom, and copper lid. The inspection of copper material is challenging due to the anisotropic properties of the material and local changes in the grain size of the copper material. The cast iron insert has some acoustical material property variation (attenuation, velocity changes, scattering properties), which make the ultrasonic inspection demanding from calibration point of view. Mainly three different methods are used for inspection. Ultrasonic testing technique is used for inspection of volume, eddy current technique, for copper components only, and visual testing technique are used for inspection of the surface and near surface area

  18. Spent nuclear fuel disposal liability insurance

    International Nuclear Information System (INIS)

    Martin, D.W.

    1984-01-01

    This thesis examines the social efficiency of nuclear power when the risks of accidental releases of spent fuel radionuclides from a spent fuel disposal facility are considered. The analysis consists of two major parts. First, a theoretical economic model of the use of nuclear power including the risks associated with releases of radionuclides from a disposal facility is developed. Second, the costs of nuclear power, including the risks associated with a radionuclide release, are empirically compared to the costs of fossil fuel-fired generation of electricity. Under the provisions of the Nuclear Waste Policy Act of 1982, the federally owned and operated spent nuclear fuel disposal facility is not required to maintain a reserve fund to cover damages from an accidental radionuclide release. Thus, the risks of a harmful radionuclide release are not included in the spent nuclear fuel disposal fee charged to the electric utilities. Since the electric utilities do not pay the full, social costs of spent fuel disposal, they use nuclear fuel in excess of the social optimum. An insurance mechanism is proposed to internalize the risks associated with spent fueled disposal. Under this proposal, the Federal government is required to insure the disposal facility against any liabilities arising from accidental releases of spent fuel radionuclides

  19. Evaluating pharmaceutical waste disposal in pediatric units

    Directory of Open Access Journals (Sweden)

    Maria Angélica Randoli de Almeida

    Full Text Available Abstract OBJECTIVE To verify the disposal of pharmaceutical waste performed in pediatric units. METHOD A descriptive and observational study conducted in a university hospital. The convenience sample consisted of pharmaceuticals discarded during the study period. Handling and disposal during preparation and administration were observed. Data collection took place at pre-established times and was performed using a pre-validated instrument. RESULTS 356 drugs disposals were identified (35.1% in the clinic, 31.8% in the intensive care unit, 23.8% in the surgical unit and 9.3% in the infectious diseases unit. The most discarded pharmacological classes were: 22.7% antimicrobials, 14.8% electrolytes, 14.6% analgesics/pain killers, 9.5% diuretics and 6.7% antiulcer agents. The most used means for disposal were: sharps’ disposable box with a yellow bag (30.8%, sink drain (28.9%, sharps’ box with orange bag (14.3%, and infectious waste/bin with a white bag (10.1%. No disposal was identified after drug administration. CONCLUSION A discussion of measures that can contribute to reducing (healthcare waste volume with the intention of engaging reflective team performance and proper disposal is necessary.

  20. The Dutch geologic radioactive waste disposal project

    International Nuclear Information System (INIS)

    Hamstra, J.; Verkerk, B.

    1981-01-01

    The Final Report reviews the work on geologic disposal of radioactive waste performed in the Netherlands over the period 1 January 1978 to 31 December 1979. The attached four topical reports cover detailed subjects of this work. The radionuclide release consequences of an accidental flooding of the underground excavations during the operational period was studied by the institute for Atomic Sciences in Agriculture (Italy). The results of the quantitative examples made for different effective cross-sections of the permeable layer connecting the mine excavations with the boundary of the salt dome, are that under all circumstances the concentration of the waste nuclides in drinking water will remain well within the ICRP maximum permissible concentrations. Further analysis work was done on what minima can be achieved for both the maximum local rock salt temperatures at the disposal borehole walls and the maximum global rock salt temperatures halfway between a square of disposal boreholes. Different multi-layer disposal configurations were analysed and compared. A more detailed description is given of specific design and construction details of a waste repository such as the shaft sinking and construction, the disposal mine development, the mine ventilation and the different plugging and sealing procedures for both the disposal boreholes and the shafts. Thanks to the hospitality of the Gesellschaft fuer Strahlenforschung, an underground working area in the Asse mine became available for performing a dry drilling experiment, which resulted successfully in the drilling of a 300 m deep disposal borehole from a mine room at the -750 m level

  1. Geological aspects of radioactive waste disposal

    International Nuclear Information System (INIS)

    Kobera, P.

    1985-01-01

    Geological formations suitable for burying various types of radioactive wastes are characterized applying criteria for the evaluation and selection of geological formations for building disposal sites for radioactive wastes issued in IAEA technical recommendations. They are surface disposal sites, disposal sites in medium depths and deep disposal sites. Attention is focused on geological formations usable for injecting self-hardening mixtures into cracks prepared by hydraulic decomposition and for injecting liquid radioactive wastes into permeable rocks. Briefly outlined are current trends of the disposal of radioactive wastes in Czechoslovakia and the possibilities are assessed from the geological point of view of building disposal sites for radioactive wastes on the sites of Czechoslovak nuclear power plants at Jaslovske Bohunice, Mochovce, Dukovany, Temelin, Holice (eastern Bohemia), Blahoutovice (northern Moravia) and Zehna (eastern Slovakia). It is stated that in order to design an optimal method of the burial of radioactive waste it will be necessary to improve knowledge of geological conditions in the potential disposal sites at the said nuclear plants. There is usually no detailed knowledge of geological and hydrological conditions at greater depths than 100 m. (Z.M.)

  2. The disposal of radioactive waste on land

    Energy Technology Data Exchange (ETDEWEB)

    None

    1957-09-01

    A committee of geologists and geophysicists was established by the National Academy of Sciences-National Research Council at the request of the Atomic Energy Commission to consider the possibilities of disposing of high level radioactive wastes in quantity within the continental limits of the United States. The group was charged with assembling the existing geologic information pertinent to disposal, delineating the unanswered problems associated with the disposal schemes proposed, and point out areas of research and development meriting first attention; the committee is to serve as continuing adviser on the geological and geophysical aspects of disposal and the research and development program. The Committee with the cooperation of the Johns Hopkins University organized a conference at Princeton in September 1955. After the Princeton Conference members of the committee inspected disposal installations and made individual studies. Two years consideration of the disposal problems leads to-certain general conclusions. Wastes may be disposed of safely at many sites in the United States but, conversely, there are many large areas in which it is unlikely that disposal sites can be found, for example, the Atlantic Seaboard. Disposal in cavities mined in salt beds and salt domes is suggested as the possibility promising the most practical immediate solution of the problem. In the future the injection of large volumes of dilute liquid waste into porous rock strata at depths in excess of 5,000 feet may become feasible but means of rendering, the waste solutions compatible with the mineral and fluid components of the rock must first be developed. The main difficulties, to the injection method recognized at present are to prevent clogging of pore space as the solutions are pumped into the rock and the prediction or control of the rate and direction of movement.

  3. COMPARISON OF DRY NEEDLING VS. SHAM ON THE PERFORMANCE OF VERTICAL JUMP

    Science.gov (United States)

    Nelson, Russell; Beamer, Lisa

    2017-01-01

    Introduction Dry needling has been reported to decrease pain in subjects having myofascial trigger points, as well as pain in muscle and connective tissue. Objective The purpose of the study was to compare the effects on the ability to perform a two-legged vertical jump between a group who received one bout of dry needling and a group who received one bout of a sham treatment. Methods Thirty-five healthy students (19 males, 16 females) were recruited to participate in this study (mean age 22.7+/- 2.4 years). The subjects were randomly divided into two groups- dry needling (n=18) vs sham (n=17). The dry needling group received needling to four sites on bilateral gastrocnemius muscles; two at the medial head and two at the lateral head. The sham group had the four areas of the gastrocnemius muscle pressed with the tube housing the needle, but the needle was never inserted into the skin. Two-legged vertical jump was measured with chalk marks on the wall before and after the dry needling and sham treatments. Results Analysis with a t-test indicated that the dry needling group significantly increased vertical jump height 1.2 inches over the sham group. Conclusion One bout of dry needling showed an immediate effect at significantly increasing vertical jump height in healthy, young adults. Future research is needed to determine if dry needling has any long-term effects. Level of Evidence 2b PMID:29181252

  4. Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Plata, Juan Camilo; Holbrook, Andrew B; Park, Yong-Lae; Pauly, Kim Butts; Daniel, Bruce L; Cutkosky, Mark R

    2014-11-01

    This study demonstrates real-time scan plane control dependent on three-dimensional needle bending, as measured from magnetic resonance imaging (MRI)-compatible optical strain sensors. A biopsy needle with embedded fiber Bragg grating (FBG) sensors to measure surface strains is used to estimate its full 3-D shape and control the imaging plane of an MR scanner in real-time, based on the needle's estimated profile. The needle and scanner coordinate frames are registered to each other via miniature radio-frequency (RF) tracking coils, and the scan planes autonomously track the needle as it is deflected, keeping its tip in view. A 3-D needle annotation is superimposed over MR-images presented in a 3-D environment with the scanner's frame of reference. Scan planes calculated based on the FBG sensors successfully follow the tip of the needle. Experiments using the FBG sensors and RF coils to track the needle shape and location in real-time had an average root mean square error of 4.2 mm when comparing the estimated shape to the needle profile as seen in high resolution MR images. This positional variance is less than the image artifact caused by the needle in high resolution SPGR (spoiled gradient recalled) images. Optical fiber strain sensors can estimate a needle's profile in real-time and be used for MRI scan plane control to potentially enable faster and more accurate physician response.

  5. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  6. COMPARISON OF DRY NEEDLING VS. SHAM ON THE PERFORMANCE OF VERTICAL JUMP.

    Science.gov (United States)

    Bandy, William D; Nelson, Russell; Beamer, Lisa

    2017-10-01

    Dry needling has been reported to decrease pain in subjects having myofascial trigger points, as well as pain in muscle and connective tissue. The purpose of the study was to compare the effects on the ability to perform a two-legged vertical jump between a group who received one bout of dry needling and a group who received one bout of a sham treatment. Thirty-five healthy students (19 males, 16 females) were recruited to participate in this study (mean age 22.7+/- 2.4 years). The subjects were randomly divided into two groups- dry needling (n=18) vs sham (n=17). The dry needling group received needling to four sites on bilateral gastrocnemius muscles; two at the medial head and two at the lateral head. The sham group had the four areas of the gastrocnemius muscle pressed with the tube housing the needle, but the needle was never inserted into the skin. Two-legged vertical jump was measured with chalk marks on the wall before and after the dry needling and sham treatments. Analysis with a t-test indicated that the dry needling group significantly increased vertical jump height 1.2 inches over the sham group. One bout of dry needling showed an immediate effect at significantly increasing vertical jump height in healthy, young adults. Future research is needed to determine if dry needling has any long-term effects. 2b.

  7. A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles

    Science.gov (United States)

    Imazu, Hiroo; Uchiyama, Yujiro; Kakutani, Hiroshi; Ikeda, kei-ichi; Sumiyama, Kazuki; Kaise, Mitsuru; Omar, Salem; Ang, Tiing Leong; Tajiri, Hisao

    2009-01-01

    Background and Aims. There are limited data on the differences in diagnostic yield between 25-gauge and 22-gauge EUS-FNA needles. This prospective study compared the difference in diagnostic yield between a 22-gauge and a 25-gauge needle when performing EUS-FNA. Methods. Forty-three patients with intraluminal or extraluminal mass lesions and/or lymphadenopathy were enrolled prospectively. EUS-FNA was performed for each mass lesion using both 25- and 22-gauge needles. The differences in accuracy rate, scoring of needle visibility, ease of puncture and quantity of obtained specimen were evaluated. Results. The overall accuracy of 22- and 25-gauge needle was similar at 81% and 76% respectively (N.S). Likewise the visibility scores of both needles were also similar. Overall the quantity of specimen obtained higher with the 22-gauge needle (score: 1.64 vs. P < .001). However the 25-gauge needle was significantly superior to the 22-gauge needle in terms of ease of puncture (score: 1.9 vs. 1.29, P < .001) and in the quantity of specimen in the context of pancreatic mass EUS-FNA (score: 1.8 vs. 1.58, P < .05). Conclusion. The 22-gauge and 25-gauge needles have similar overall diagnostic yield. The 25-gauge needle appeared superior in the subset of patients with hard lesions and pancreatic masses. PMID:19997511

  8. A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles

    Directory of Open Access Journals (Sweden)

    Hiroo Imazu

    2009-01-01

    Full Text Available Background and Aims. There are limited data on the differences in diagnostic yield between 25-gauge and 22-gauge EUS-FNA needles. This prospective study compared the difference in diagnostic yield between a 22-gauge and a 25-gauge needle when performing EUS-FNA. Methods. Forty-three patients with intraluminal or extraluminal mass lesions and/or lymphadenopathy were enrolled prospectively. EUS-FNA was performed for each mass lesion using both 25- and 22-gauge needles. The differences in accuracy rate, scoring of needle visibility, ease of puncture and quantity of obtained specimen were evaluated. Results. The overall accuracy of 22- and 25-gauge needle was similar at 81% and 76% respectively (N.S. Likewise the visibility scores of both needles were also similar. Overall the quantity of specimen obtained higher with the 22-gauge needle (score: 1.64 vs. P<.001. However the 25-gauge needle was significantly superior to the 22-gauge needle in terms of ease of puncture (score: 1.9 vs. 1.29, P<.001 and in the quantity of specimen in the context of pancreatic mass EUS-FNA (score: 1.8 vs. 1.58, P<.05. Conclusion. The 22-gauge and 25-gauge needles have similar overall diagnostic yield. The 25-gauge needle appeared superior in the subset of patients with hard lesions and pancreatic masses.

  9. Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

    NARCIS (Netherlands)

    Dorr, H.G.; Zabransky, S.; Keller, E.; Otten, B.J.; Partsch, C.J.; Nyman, L.; Gillespie, B.K.; Lester, N.R.; Wilson, A.M.; Hyren, C.; Kuijck, M.A. van; Schuld, P.; Schoenfeld, S.L.

    2003-01-01

    The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of

  10. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  11. Nuclear fuel waste disposal in Canada

    International Nuclear Information System (INIS)

    Dormuth, K.W.; Gillespie, P.A.

    1990-05-01

    Atomic Energy of Canada Limited (AECL) has developed a concept for disposing of Canada's nuclear fuel waste and is submitting it for review under the Federal Environmental Assessment and Review Process. During this review, AECL intends to show that careful, controlled burial 500 to 1000 metres deep in plutonic rock of the Canadian Precambrian Shield is a safe and feasible way to dispose of Canada's nuclear fuel waste. The concept has been assessed without identifying or evaluating any particular site for disposal. AECL is now preparing a comprehensive report based on more than 10 years of research and development

  12. The disposal of Canada's nuclear fuel waste: engineering for a disposal facility

    International Nuclear Information System (INIS)

    Simmons, G.R.; Baumgartner, P.

    1994-01-01

    This report presents some general considerations for engineering a nuclear fuel waste disposal facility, alternative disposal-vault concepts and arrangements, and a conceptual design of a used-fuel disposal centre that was used to assess the technical feasibility, costs and potential effects of disposal. The general considerations and alternative disposal-vault arrangements are presented to show that options are available to allow the design to be adapted to actual site conditions. The conceptual design for a used-fuel disposal centre includes descriptions of the two major components of the disposal facility, the Used-Fuel Packaging Plant and the disposal vault; the ancillary facilities and services needed to carry out the operations are also identified. The development of the disposal facility, its operation, its decommissioning, and the reclamation of the site are discussed. The costs, labour requirements and schedules used to assess socioeconomic effects and that may be used to assess the cost burden of waste disposal to the consumer of nuclear energy are estimated. The Canadian Nuclear Fuel Waste Management Program is funded jointly by AECL and Ontario Hydro under the auspices of the CANDU Owners Group. (author)

  13. Structure and photoluminescence properties of Ag-coated ZnO nano-needles

    International Nuclear Information System (INIS)

    Li Xiaozhu; Wang Yongqian

    2011-01-01

    Highlights: → ZnO nano-needles were synthesized by thermal oxidation. → Their surfaces were coated with Ag by pulse electro-deposition technique. → The uncoated and coated ZnO nano-needles were characterized. → The results showed that the prepared ZnO nano-needles have been coated with Ag successfully. → The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the Ag-coated ZnO nano-needles can increase the absorption of UV light. - Abstract: A large number of zinc oxide (ZnO) nano-needles were synthesized by thermal oxidation of pure zinc. The surfaces of ZnO nano-needles were coated with a layer of Ag by pulse electro-deposition technique. The uncoated and coated ZnO nano-needles were characterized by using the X-ray diffraction and the scanning electron microscope (SEM). The results showed that the uncoated samples were close-packed hexagonal structure, which showed needle-like morphology. Their average diameter is about 40 nm, lengths up to 5 μm. At the same time we observed that the prepared ZnO nano-needles have been coated with Ag successfully. The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the uncoated ZnO nano-needles have two fluorescence peaks at 388 nm and 470.8 nm, respectively, the relative intensity of 143.4 and 93.61; and the Ag-coated ZnO nano-needles showed a pair of strong peaks at 387.4 nm and 405.2 nm, the relative intensity of 1366 and 1305, respectively, indicating that the Ag-coated ZnO nano-needles can increase the absorption of UV light.

  14. Assessment of alternative disposal concepts

    International Nuclear Information System (INIS)

    Autio, J.; Saanio, T.; Tolppanen, P.; Raiko, H.; Vieno, T.; Salo, J.P.

    1996-12-01

    Four alternative repository designs for the disposal of spent nuclear in the Finnish crystalline bedrock were assessed in the study. The alternatives were: (1) the basic KBS-3 design in which copper canisters are emplaced in vertical deposition holes bored in the floors of horizontal tunnels, (2) the KBS-3-2C design with two canisters in a deposition hole, (3) Short Horizontal Holes (SHH) in the side walls of the tunnels, and (4) the Medium Long Holes (MLH) concept in which approximately 25 canisters are emplaced in a horizontal deposition hole about 200 metres in length bored between central and side tunnels. In all the alternatives considered, the thickness of the layer of compacted bentonite between copper canister and bedrock is 35 cm. Two different copper canister designs were also assessed. Technical feasibility and flexibility, post-closure safety and repository cost were assessed for each of the alternative canister and repository designs. On the basis of this assessment it is recommended that further development and studies should focus on the vacuum- or inert gas-filled cast insert type copper canister and the basic KBS-3 type repository design with a single canister in a vertical deposition hole. The KBS-3 design is robust and flexible and provides excellent post-closure safety. The transfer, emplacement and sealing operations are technically uncomplicated. The alternative options assessed do not offer any significant benefits in safety or cost over the basic design, but they are technically more complex and also in some respects more vulnerable to malfunction during the emplacement of canisters and buffer, as well as common mode failures. (60 refs.)

  15. Marine disposal of radioactive wastes

    International Nuclear Information System (INIS)

    Woodhead, D.S.

    1980-01-01

    In a general sense, the main attraction of the marine environment as a repository for the wastes generated by human activities lies in the degree of dispersion and dilution which is readily attainable. However, the capacity of the oceans to receive wastes without unacceptable consequences is clearly finite and this is even more true of localized marine environments such as estuaries, coastal waters and semi-enclosed seas. Radionuclides have always been present in the marine environment and marine organisms and humans consuming marine foodstuffs have always been exposed, to some degree, to radiation from this source. The hazard associated with ionizing radiations is dependent upon the adsorption of energy from the radiation field within some biological entity. Thus any disposal of radioactive wastes into the marine environment has consequences, the acceptability of which must be assessed in terms of the possible resultant increase in radiation exposure of human and aquatic populations. In the United Kingdom the primary consideration has been and remains the safe-guarding of public health. The control procedures are therefore designed to minimize as far as practicable the degree of human exposure within the overall limits recommended as acceptable by the International Commission on Radiological Protection. There are several approaches through which control could be exercised and the strenghs and weaknesses of each are considered. In this review the detailed application of the critical path technique to the control of the discharge into the north-east Irish Sea from the fuel reprocessing plant at Windscale is given as a practical example. It will be further demonstrated that when human exposure is controlled in this way no significant risk attaches to the increased radiation exposure experienced by populations of marine organisms in the area. (orig.) [de

  16. Uranium solubility and solubility controls in selected Needle's Eye groundwaters

    International Nuclear Information System (INIS)

    Falck, W.E.; Hooker, P.J.

    1992-01-01

    The British Geological Survey (BGS) has been co-ordinating a research programme centred on the Needle's Eye natural analogue site in Dumfries and Galloway District, southwest Scotland. This study of a natural radioactive geochemical system has been carried out with the aim of improving confidence in using geochemical and predictive models of radionuclide (uranium) migration in the geosphere. The Needle's Eye site is located on the Solway Coat within the Southwick Coast Reserve of the Scottish Wildlife Trust who gave permission to sample for soils, sediments and waters for analysis. This report is one of a series and covers the period from June 1989 to June 1990. It presents the results of applying the PHREEQE code to the hydrochemistry of the site using the CHEMVAL thermodynamic database. (author)

  17. Needles of Pinus halepensis as biomonitors of bioaerosol emissions.

    Directory of Open Access Journals (Sweden)

    Amandine Galès

    Full Text Available We propose using the surface of pine trees needles to biomonitor the bioaerosol emissions at a composting plant. Measurements were based on 16S rRNA gene copy numbers of Saccharopolyspora rectivirgula, a bioindicator of composting plant emissions. A sampling plan was established based on 29 samples around the emission source. The abundance of 16S rRNA gene copies of S. rectivirgula per gram of Pinus halepensis needles varied from 104 to 102 as a function of the distance. The signal reached the background level at distances around the composting plant ranging from 2 km to more than 5.4 km, depending on the local topography and average wind directions. From these values, the impacted area around the source of bioaerosols was mapped.

  18. Silica needle template fabrication of metal hollow microneedle arrays

    International Nuclear Information System (INIS)

    Zhu, M W; Li, H W; Chen, X L; Tang, Y F; Lu, M H; Chen, Y F

    2009-01-01

    Drug delivery through hollow microneedle (HMN) arrays has now been recognized as one of the most promising techniques because it minimizes the shortcomings of the traditional drug delivery methods and has many exciting advantages—pain free and tunable release rates, for example. However, this drug delivery method has been hindered greatly from mass clinical application because of the high fabrication cost of HMN arrays. Hence, we developed a simple and cost-effective procedure using silica needles as templates to massively fabricate HMN arrays by using popular materials and industrially applicable processes of micro- imprint, hot embossing, electroplating and polishing. Metal HMN arrays with high quality are prepared with great flexibility with tunable parameters of area, length of needle, size of hollow and array dimension. This efficient and cost-effective fabrication method can also be applied to other applications after minor alterations, such as preparation of optic, acoustic and solar harvesting materials and devices

  19. Silica needle template fabrication of metal hollow microneedle arrays

    Science.gov (United States)

    Zhu, M. W.; Li, H. W.; Chen, X. L.; Tang, Y. F.; Lu, M. H.; Chen, Y. F.

    2009-11-01

    Drug delivery through hollow microneedle (HMN) arrays has now been recognized as one of the most promising techniques because it minimizes the shortcomings of the traditional drug delivery methods and has many exciting advantages—pain free and tunable release rates, for example. However, this drug delivery method has been hindered greatly from mass clinical application because of the high fabrication cost of HMN arrays. Hence, we developed a simple and cost-effective procedure using silica needles as templates to massively fabricate HMN arrays by using popular materials and industrially applicable processes of micro- imprint, hot embossing, electroplating and polishing. Metal HMN arrays with high quality are prepared with great flexibility with tunable parameters of area, length of needle, size of hollow and array dimension. This efficient and cost-effective fabrication method can also be applied to other applications after minor alterations, such as preparation of optic, acoustic and solar harvesting materials and devices.

  20. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve....... The aim of this article is to review the role of EUS-guided nCLE in modern endoscopy and its implications in molecular imaging....