WorldWideScience

Sample records for display variable anatomic

  1. Tools to analyse and display variations in anatomical delineation

    International Nuclear Information System (INIS)

    Ebert, Martin A.; McDermott, L.N.; Haworth, A; Van der Wath, E.; Hooton, B.

    2012-01-01

    Variations in anatomical delineation, principally due to a combination of inter-observer contributions and image-specificity, remain one of the most significant impediments to geometrically-accurate radiotherapy. Quantification of spatial variability of the delineated contours comprising a structure can be made with a variety of metrics, and the availability of software tools to apply such metrics to data collected during inter-observer or repeat-imaging studies would allow their validation. A suite of such tools have been developed which use an Extensible Markup Language format for the exchange of delineated 3D structures with radiotherapy planning or review systems. These tools provide basic operations for manipulating and operating on individual structures and related structure sets, and for deriving statistics on spatial variations of contours that can be mapped onto the surface of a reference structure. Use of these tools on a sample dataset is demonstrated together with import and display of results in the SWAN treatment plan review system.

  2. A variable-collimation display system

    Science.gov (United States)

    Batchko, Robert; Robinson, Sam; Schmidt, Jack; Graniela, Benito

    2014-03-01

    Two important human depth cues are accommodation and vergence. Normally, the eyes accommodate and converge or diverge in tandem; changes in viewing distance cause the eyes to simultaneously adjust both focus and orientation. However, ambiguity between accommodation and vergence cues is a well-known limitation in many stereoscopic display technologies. This limitation also arises in state-of-the-art full-flight simulator displays. In current full-flight simulators, the out-the-window (OTW) display (i.e., the front cockpit window display) employs a fixed collimated display technology which allows the pilot and copilot to perceive the OTW training scene without angular errors or distortions; however, accommodation and vergence cues are limited to fixed ranges (e.g., ~ 20 m). While this approach works well for long-range, the ambiguity of depth cues at shorter range hinders the pilot's ability to gauge distances in critical maneuvers such as vertical take-off and landing (VTOL). This is the first in a series of papers on a novel, variable-collimation display (VCD) technology that is being developed under NAVY SBIR Topic N121-041 funding. The proposed VCD will integrate with rotary-wing and vertical take-off and landing simulators and provide accurate accommodation and vergence cues for distances ranging from approximately 3 m outside the chin window to ~ 20 m. A display that offers dynamic accommodation and vergence could improve pilot safety and training, and impact other applications presently limited by lack of these depth cues.

  3. Anatomic variability of the vascularized composite osteomyocutaneous flap from the medial femoral condyle: an anatomical study

    Directory of Open Access Journals (Sweden)

    Trung-Hau Le Thua

    2014-12-01

    Full Text Available Aim: The anatomical study and clinical application for the vascularized corticoperiosteal flap from the medial femoral condyle have been performed and described previously. Although prior studies have described the composite osteomyocutaneous flap from the medial femoral condyle, a detailed analysis of the vascularity of this region has not yet been fully evaluated. Methods: This anatomical study described the variability of the arteries from the medial femoral condyle in 40 cadaveric specimens. Results: The descending genicular artery (DGA was found in 33 of 40 cases (82.5%. The  superomedial genicular artery (SGA was present in 10 cases (25%. All 33 cases (100% of the DGA had articular branches to the periosteum of the medial femoral condyle. Muscular branches and saphenous branches of the DGA were present in 25 cases (62.5% and 26 cases (70.3%, respectively. Conclusion: The current study demonstrates that the size and length of the vessels to the medial femoral condyle are sufficient for a vascularized bone flap. A careful preoperative vascular assessment is essential prior to use of the vascularized composite osteomyocutaneous flap from the medial femoral condyle, because of the considerable anatomical variations in different branches of the DGA.

  4. Production of a phage-displayed single chain variable fragment ...

    African Journals Online (AJOL)

    Purpose: To develop specific single chain variable fragments (scFv) against infectious bursal disease virus (IBDV) via phage display technology. Methods: Purified viruses were initially applied for iterative panning rounds of scFv phage display libraries. The binding ability of the selected scFv antibody fragments against the ...

  5. Variability of anatomical-physiological traits in black locust clones - Robinia pseudoacacia L

    Directory of Open Access Journals (Sweden)

    Orlović Saša S.

    2004-01-01

    Full Text Available Variability within R. pseudoacacia species represents an important factor in selection of fast-growing genotypes. Therefore, it is important to identify superior individuals according to their anatomical and physiological traits. This paper presents the results of a study of genotype variability of the main leaf anatomical (frequency, length and width of stomata, leaflet thickness among veins, leaflet thickness on the main vein, mesophyll thickness, length and width of vascular bundle of main vein and physiological (leaf area, photosynthetic pigments content and content of N P, K, Ca, Na parameters among five clones of Robinia pseudoacacia L. Significant interclonal variations were observed in the investigated parameters. Clone R-56 had the highest N, P, and K concentrations, the largest mesophyll volume and the highest pigment concentration. We concluded that the clone R-56, although without a remarkable leaf area, possesses the ability for high photosynthetic production. The results are going to be used in further work on selection.

  6. Anatomic variables affecting interdental papilla

    Directory of Open Access Journals (Sweden)

    Swapna A. Mahale

    2013-01-01

    Full Text Available Aim: The aim of this study is to evaluate the anatomic variables affecting the interdental papilla. Materials and Methods: Thirty adult patients were evaluated. Papilla score (PS, tooth form/shape, gingival thickness, crest bone height and keratinized gingiva/attached gingiva were recorded for 150 inter proximal sites. Data were analyzed using SPSS software package (version 7.0 and the significance level was set at 95% confidence interval. Pearson′s correlation was applied to correlate the relationship between the factors and the appearance of the papilla. Results: Competent papillae (complete fill interdentally were associated with: (1 Crown width (CW: length ≥0.87; (2 bone crest-contact point ≤5 mm; and (3 inter proximal gingival tissue thickness ≥1.5 mm. Gingival thickness correlated negatively with PS (r = −0.37 to −0.54 and positively with tissue height (r = 0.23-0.43. Tooth form (i.e., CW to length ratio correlated negatively with PS (r = −0.37 to −0.61. Conclusion: Gingival papilla appearance was associated significantly with tooth form/shape, crestal bone height and interproximal gingival thickness.

  7. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Segars, W. P.; Bond, Jason; Frush, Jack; Hon, Sylvia; Eckersley, Chris; Samei, E. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Williams, Cameron H.; Frush, D. [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Feng Jianqiao; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I. [Center for Imaging Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2013-04-15

    Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve

  8. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

    International Nuclear Information System (INIS)

    Segars, W. P.; Bond, Jason; Frush, Jack; Hon, Sylvia; Eckersley, Chris; Samei, E.; Williams, Cameron H.; Frush, D.; Feng Jianqiao; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.

    2013-01-01

    Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest–abdomen–pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore

  9. Variability in anatomical features of human clavicle: Its forensic anthropological and clinical significance

    Directory of Open Access Journals (Sweden)

    Jagmahender Singh Sehrawat

    2016-06-01

    Full Text Available Bones can reflect the basic framework of human body and may provide valuable information about the biological identity of the deceased. They, often, survive the morphological alterations, taphonomic destructions, decay/mutilation and decomposition insults. In-depth knowledge of variations in clavicular shape, size and its dimensions is very important from both clinical (fixation of clavicular fractures using external or inter-medullary devices, designing orthopedic fixation devices as well as forensic anthropological perspectives. Human clavicle is the most frequently fractured bone of human skeleton, possessing high degree of variability in its anatomical, biomechanical and morphological features. Extended period of skeletal growth (up to third decade in clavicle imparts it an additional advantage for forensic identification purposes. In present study, five categories of clavicular features like lengths, diameters, angles, indices and robustness were examined to explore the suitability of collarbone for forensic and clinical purposes. For this purpose, 263 pairs of adult clavicles (195 Males and 68 Females were collected from autopsied cadavers and were studied for 13 anatomical features. Gender and occupational affiliations of cadavers were found to have significant influences on anatomical dimensions of their clavicles. Product index, weight and circumference of collarbone were found the best univariate variables, discriminating sex of more than 80% individuals. The best multivariate Function-I (DF: -17.315 + 0.054 CL-L+0.196 CC-R+0.184 DM-L could identify sex and occupation of 89.4% (89.2% Male and 89.7% Female and 65.4% individuals, respectively. All clavicular variables were found bilaterally asymmetric; left clavicles being significantly longer in length, lighter in weight, smooth in texture and less curved than the right side bones. Among non-metric traits, sub-clavian groove, nutrient foramina and ‘type’ of clavicle exhibited

  10. Assessing display variability in wild brown anoles Anolis sagrei using a mechanical lizard model

    Directory of Open Access Journals (Sweden)

    Sarah R. PARTAN, Peter OTOVIC, Virginia L. PRICE, Scott E. BROWN

    2011-04-01

    Full Text Available Signals used for species identity ought to be highly stereotyped so as to facilitate immediate recognition by conspecifics. It is surprising therefore to find variability in putative species signature displays. The brown anole Anolis sagrei has a high degree of variability in its signature bobbing display. In this study we collected descriptive data on variability in the temporal structure of wild brown anole bobbing patterns, finding that no two displays analyzed had the same temporal structure, and we also tested whether wild brown anoles prefer the signature display over an alternate display pattern by using mechanical robot playbacks in the field. As a response metric we assessed whether or not the lizards showed social responses (pushup, dewlap extension, or head-nod in response to the robotic presentations. We found that the lizards responded slightly more to the signature than to the alternate pattern, providing support for the idea that despite the variability seen in displays, the signature pattern is meaningful to them. We tested two other independent variables: speed of the display and elevation of the robot during its display, neither of which was significant. Dewlap extensions were given predominantly by adult males and were more likely to be given in the breeding season than the nonbreeding season. Pushups and head-nods were given equally by males and a combined class of females and juveniles, and were not seasonal. Head-nods increased after the robot turned off, suggesting that they may be used in a conversational turn-taking style during communication [Current Zoology 57 (2: 140–152, 2011].

  11. Seasonal variability in physiological and anatomical traits contributes to invasion success of Prosopis juliflora in tropical dry forest.

    Science.gov (United States)

    Oliveira, Marciel T; Souza, Gustavo M; Pereira, Silvia; Oliveira, Deborah A S; Figueiredo-Lima, Karla V; Arruda, Emília; Santos, Mauro G

    2017-03-01

    We investigated whether there were consistent differences in the physiological and anatomical traits and phenotypic variability of an invasive (Prosopis juliflora (Sw.) DC.) and native species (Anadenanthera colubrina (Vell.) Brenan) in response to seasonality in a tropical dry forest. The water potential, organic solutes, gas exchange, enzymes of the antioxidant system, products of oxidative stress and anatomical parameters were evaluated in both species in response to seasonality. An analysis of physiological responses indicated that the invasive P. juliflora exhibited higher response in net photosynthetic rate to that of the native species between seasons. Higher values of water potential of the invasive species than those of the native species in the dry season indicate a more efficient mechanism for water regulation in the invasive species. The invasive species exhibits a thicker cuticle and trichomes, which can reduce transpiration. In combination, the increased epidermal thickness and the decreased thickness of the parenchyma in the dry season may contribute to water saving. Our data suggest a higher variability in anatomical traits in the invasive species as a response to seasonality, whereas physiological traits did not present a clear pattern of response. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Anatomical variability of the trunk wood and root tissues of ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the anatomical structure of the trunk wood and the roots of A. nitida and R. racemosa, two mangrove trees from Gabon. The anatomical differences between the trunks and the roots were used to understand their bio-remediating differences through heavy metals. It was found that the ...

  13. Variability of the inclination of anatomic horizontal reference planes of the craniofacial complex in relation to the true horizontal line in orthognathic patients.

    Science.gov (United States)

    Zebeib, Ameen M; Naini, Farhad B

    2014-12-01

    The purpose of this study was to assess the reliability of the Frankfort horizontal (FH), sella-nasion horizontal, and optic planes in terms of their variabilities in relation to a true horizontal line in orthognathic surgery patients. Thirty-six consecutive presurgical orthognathic patients (13 male, 23 female; age range, 16-35 years; 30 white, 6 African Caribbean) had lateral cephalometric radiographs taken in natural head position, with a plumb line orientating the true vertical line, and the true horizontal line perpendicular to the true vertical. The inclinations of the anatomic reference planes were compared with the true horizontal. The FH plane was found to be on average closest to the true horizontal, with a mean of -1.6° (SD, 3.4°), whereas the sella-nasion horizontal and the optic plane had means of 2.1° (SD, 5.1°) and 3.2° (SD, 4.7°), respectively. The FH showed the least variability of the 3 anatomic planes. The ranges of variability were high for all anatomic planes: -8° to 8° for the FH, -8° to 15° for the sella-nasion horizontal, and -6° to 13° for the optic plane. No significant differences were found in relation to patients' sex, skeletal patterns, or ethnic backgrounds. The clinically significant variability in the inclinations of anatomic reference planes in relation to the true horizontal plane makes their use unreliable in orthognathic patients. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Contextual cueing of tactile search is coded in an anatomical reference frame.

    Science.gov (United States)

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. Computer aided display of multiple soft tissue anatomical surfaces for simultaneous structural and area-dose appreciation in 3D-radiationtherapy planning. 115

    International Nuclear Information System (INIS)

    Moore, C.J.; Mott, D.J.; Wilkinson, J.M.

    1987-01-01

    For radiotherapy applications a 3D display that includes soft tissues is required but the presentation of all anatomical structures is often unnecessary and is potentially confusing. A tumour volume and a small number of critical organs, usually embedded within other soft tissue anatomy, are likely to be all that can be clearly displayed when presented in a 3D format. The inclusion of dose data (in the form of isodose lines or surfaces) adds to the complication of any 3D display. A solution to this problem is to incorporate the presentation of dose distribution into the technique used to provide the illusion of 3D. This illusion can be provided by either depth cueing or by the hypothetical illumination of spatially defined object surfaces. The dose distribution from irradiation fields or, in the case of brachytherapy from radioactive sources, can be regarded as a source of illumination for tumour and critical organs. The intensity of illumination at any point on a tissue surface represents the dose at that point. Such an approach also allows the variation of dose over a given surface (and by extension, over the corresponding volume) to be quantified using histogram techniques. This may be of value in analysing and comparing techniques in which vulnerable tissue surfaces are irradiated. The planning of intracavitary treatments for cervical cancer is one application which might benefit from the display approach described above. Here the variation of dose over the mucosal surfaces of the bladder and the rectum is of particular interest, since dose related morbidity has often been reported following these treatments. 7 refs.; 8 figs

  16. Exploring brain function from anatomical connectivity

    Directory of Open Access Journals (Sweden)

    Gorka eZamora-López

    2011-06-01

    Full Text Available The intrinsic relationship between the architecture of the brain and the range of sensory and behavioral phenomena it produces is a relevant question in neuroscience. Here, we review recent knowledge gained on the architecture of the anatomical connectivity by means of complex network analysis. It has been found that corticocortical networks display a few prominent characteristics: (i modular organization, (ii abundant alternative processing paths and (iii the presence of highly connected hubs. Additionally, we present a novel classification of cortical areas of the cat according to the role they play in multisensory connectivity. All these properties represent an ideal anatomical substrate supporting rich dynamical behaviors, as-well-as facilitating the capacity of the brain to process sensory information of different modalities segregated and to integrate them towards a comprehensive perception of the real world. The result here exposed are mainly based in anatomical data of cats’ brain, but we show how further observations suggest that, from worms to humans, the nervous system of all animals might share fundamental principles of organization.

  17. Prevalence and anatomical pattern of the median artery among ...

    African Journals Online (AJOL)

    Knowledge of the anatomy of median arteries is important in the diagnosis and management of carpal tunnel and pronator teres syndromes, reconstructive surgery in the forearm, minimizing inadvertent vascular injury as well as in limiting operative complications due to unexpected bleeding. The anatomical pattern displays ...

  18. Recent advances in standards for collaborative Digital Anatomic Pathology

    Science.gov (United States)

    2011-01-01

    Context Collaborative Digital Anatomic Pathology refers to the use of information technology that supports the creation and sharing or exchange of information, including data and images, during the complex workflow performed in an Anatomic Pathology department from specimen reception to report transmission and exploitation. Collaborative Digital Anatomic Pathology can only be fully achieved using medical informatics standards. The goal of the international integrating the Healthcare Enterprise (IHE) initiative is precisely specifying how medical informatics standards should be implemented to meet specific health care needs and making systems integration more efficient and less expensive. Objective To define the best use of medical informatics standards in order to share and exchange machine-readable structured reports and their evidences (including whole slide images) within hospitals and across healthcare facilities. Methods Specific working groups dedicated to Anatomy Pathology within multiple standards organizations defined standard-based data structures for Anatomic Pathology reports and images as well as informatic transactions in order to integrate Anatomic Pathology information into the electronic healthcare enterprise. Results The DICOM supplements 122 and 145 provide flexible object information definitions dedicated respectively to specimen description and Whole Slide Image acquisition, storage and display. The content profile “Anatomic Pathology Structured Report” (APSR) provides standard templates for structured reports in which textual observations may be bound to digital images or regions of interest. Anatomic Pathology observations are encoded using an international controlled vocabulary defined by the IHE Anatomic Pathology domain that is currently being mapped to SNOMED CT concepts. Conclusion Recent advances in standards for Collaborative Digital Anatomic Pathology are a unique opportunity to share or exchange Anatomic Pathology structured

  19. Analysis of anatomic variability in children with low mathematical skills

    Science.gov (United States)

    Han, Zhaoying; Fuchs, Lynn; Davis, Nikki; Cannistraci, Christopher J.; Anderson, Adam W.; Gore, John C.; Dawant, Benoit M.

    2008-03-01

    Mathematical difficulty affects approximately 5-9% of the population. Studies on individuals with dyscalculia, a neurologically based math disorder, provide important insight into the neural correlates of mathematical ability. For example, cognitive theories, neuropsychological studies, and functional neuroimaging studies in individuals with dyscalculia suggest that the bilateral parietal lobes and intraparietal sulcus are central to mathematical performance. The purpose of the present study was to investigate morphological differences in a group of third grade children with poor math skills. We compare population averages of children with low math skill (MD) to gender and age matched controls with average math ability. Anatomical data were gathered with high resolution MRI and four different population averaging methods were used to study the effect of the normalization technique on the results. Statistical results based on the deformation fields between the two groups show anatomical differences in the bilateral parietal lobes, right frontal lobe, and left occipital/parietal lobe.

  20. Modular Construction of Large Non-Immune Human Antibody Phage-Display Libraries from Variable Heavy and Light Chain Gene Cassettes.

    Science.gov (United States)

    Lee, Nam-Kyung; Bidlingmaier, Scott; Su, Yang; Liu, Bin

    2018-01-01

    Monoclonal antibodies and antibody-derived therapeutics have emerged as a rapidly growing class of biological drugs for the treatment of cancer, autoimmunity, infection, and neurological diseases. To support the development of human antibodies, various display techniques based on antibody gene repertoires have been constructed over the last two decades. In particular, scFv-antibody phage display has been extensively utilized to select lead antibodies against a variety of target antigens. To construct a scFv phage display that enables efficient antibody discovery, and optimization, it is desirable to develop a system that allows modular assembly of highly diverse variable heavy chain and light chain (Vκ and Vλ) repertoires. Here, we describe modular construction of large non-immune human antibody phage-display libraries built on variable gene cassettes from heavy chain and light chain repertoires (Vκ- and Vλ-light can be made into independent cassettes). We describe utility of such libraries in antibody discovery and optimization through chain shuffling.

  1. Benchmarking Academic Anatomic Pathologists

    Directory of Open Access Journals (Sweden)

    Barbara S. Ducatman MD

    2016-10-01

    Full Text Available The most common benchmarks for faculty productivity are derived from Medical Group Management Association (MGMA or Vizient-AAMC Faculty Practice Solutions Center ® (FPSC databases. The Association of Pathology Chairs has also collected similar survey data for several years. We examined the Association of Pathology Chairs annual faculty productivity data and compared it with MGMA and FPSC data to understand the value, inherent flaws, and limitations of benchmarking data. We hypothesized that the variability in calculated faculty productivity is due to the type of practice model and clinical effort allocation. Data from the Association of Pathology Chairs survey on 629 surgical pathologists and/or anatomic pathologists from 51 programs were analyzed. From review of service assignments, we were able to assign each pathologist to a specific practice model: general anatomic pathologists/surgical pathologists, 1 or more subspecialties, or a hybrid of the 2 models. There were statistically significant differences among academic ranks and practice types. When we analyzed our data using each organization’s methods, the median results for the anatomic pathologists/surgical pathologists general practice model compared to MGMA and FPSC results for anatomic and/or surgical pathology were quite close. Both MGMA and FPSC data exclude a significant proportion of academic pathologists with clinical duties. We used the more inclusive FPSC definition of clinical “full-time faculty” (0.60 clinical full-time equivalent and above. The correlation between clinical full-time equivalent effort allocation, annual days on service, and annual work relative value unit productivity was poor. This study demonstrates that effort allocations are variable across academic departments of pathology and do not correlate well with either work relative value unit effort or reported days on service. Although the Association of Pathology Chairs–reported median work relative

  2. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  3. Effect of anatomical variability in brain on transcranial magnetic stimulation treatment

    Science.gov (United States)

    Syeda, F.; Magsood, H.; Lee, E. G.; El-Gendy, A. A.; Jiles, D. C.; Hadimani, R. L.

    2017-05-01

    Transcranial Magnetic Stimulation is a non-invasive clinical therapy used to treat depression and migraine, and shows further promise as treatment for Parkinson's disease, Alzheimer's disease, and other neurological disorders. However, it is yet unclear as to how anatomical differences may affect stimulation from this treatment. We use finite element analysis to model and analyze the results of Transcranial Magnetic Stimulation in various head models. A number of heterogeneous head models have been developed using MRI data of real patients, including healthy individuals as well as patients of Parkinson's disease. Simulations of Transcranial Magnetic Stimulation performed on 22 anatomically different models highlight the differences in induced stimulation. A standard Figure of 8 coil is used with frequency 2.5 kHz, placed 5 mm above the head. We compare cortical stimulation, volume of brain tissue stimulated, specificity, and maximum E-field induced in the brain for models ranging from ages 20 to 60. Results show that stimulation varies drastically between patients of the same age and health status depending upon brain-scalp distance, which is not necessarily a linear progression with age.

  4. Variability of femoral muscle attachments.

    Science.gov (United States)

    Duda, G N; Brand, D; Freitag, S; Lierse, W; Schneider, E

    1996-09-01

    Analytical and experimental models of the musculoskeletal system often assume single values rather than ranges for anatomical input parameters. The hypothesis of the present study was that anatomical variability significantly influences the results of biomechanical analyses, specifically regarding the moment arms of the various thigh muscles. Insertions and origins of muscles crossing or attaching to the femur were digitized in six specimens. Muscle volumes were measured; muscle attachment area and centroid location were computed. To demonstrate the influence of inter-individual anatomic variability on a mechanical modeling parameter, the corresponding range of muscle moment arms were calculated. Standard deviations, as a percentage of the mean, were about 70% for attachment area and 80% for muscle volume and attachment centroid location. The resulting moment arms of the m. gluteus maximus and m. rectus femoris were especially sensitive to anatomical variations (SD 65%). The results indicate that sensitivity to anatomical variations should be analyzed in any investigation simulating musculoskeletal interactions. To avoid misinterpretations, investigators should consider using several anatomical configurations rather than relying on a mean data set.

  5. Characterization of Capsicum species using anatomical and molecular data.

    Science.gov (United States)

    Dias, G B; Gomes, V M; Moraes, T M S; Zottich, U P; Rabelo, G R; Carvalho, A O; Moulin, M; Gonçalves, L S A; Rodrigues, R; Da Cunha, M

    2013-02-28

    Capsicum species are frequently described in terms of genetic divergence, considering morphological, agronomic, and molecular databases. However, descriptions of genetic differences based on anatomical characters are rare. We examined the anatomy and the micromorphology of vegetative and reproductive organs of several Capsicum species. Four Capsicum accessions representing the species C. annuum var. annuum, C. baccatum var. pendulum, C. chinense, and C. frutescens were cultivated in a greenhouse; leaves, fruits and seeds were sampled and their organ structure analyzed by light and scanning electronic microscopy. Molecular accession characterization was made using ISSR markers. Polymorphism was observed among tector trichomes and also in fruit color and shape. High variability among accessions was detected by ISSR markers. Despite the species studied present a wide morphological and molecular variability that was not reflected by anatomical features.

  6. The variability of Scots pine from Piekielna Góra as expressed by morphological and anatomical traits of needles

    Directory of Open Access Journals (Sweden)

    Maria A. Bobowicz

    2014-01-01

    Full Text Available Two-year old needles were collected from 30 standing Scots pine trees on Piekielna Góra. These needles were analysed in respect to 13 morphological and anatomical traits. The data so obtained was subjected to a whole range of multi-trait analytical methods in an attempt to determine the variability among the randomly chosen trees. Multivariate analysis of variance and canonical analysis were done as well as calculation of Mahalanobis distances between each pair of trees and their significance was tested by the Hotelling T2 statistics. Aminimum spanning tree was constructed on the basis of the shortest Mahalanobis distances, while a dendrogram (cluster analysis was compiled on the basis of Euclidean distances. It was found that in spite of the fact that the studied population sample of pines did not form internal, significantly differentiated groups, the variability among particular trees was large and depended on the given trait. The number of resin canals best differentiated the studied trees, while the Marcet coefficient did not significantly differentia­te any pair of trees.

  7. A Computational Model Quantifies the Effect of Anatomical Variability on Velopharyngeal Function

    Science.gov (United States)

    Inouye, Joshua M.; Perry, Jamie L.; Lin, Kant Y.; Blemker, Silvia S.

    2015-01-01

    Purpose: This study predicted the effects of velopharyngeal (VP) anatomical parameters on VP function to provide a greater understanding of speech mechanics and aid in the treatment of speech disorders. Method: We created a computational model of the VP mechanism using dimensions obtained from magnetic resonance imaging measurements of 10 healthy…

  8. Effects of display set size and its variability on the event-related potentials during a visual search task

    OpenAIRE

    Miyatani, Makoto; Sakata, Sumiko

    1999-01-01

    This study investigated the effects of display set size and its variability on the event-related potentials (ERPs) during a visual search task. In Experiment 1, subjects were required to respond if a visual display, which consisted of two, four, or six alphabets, contained one of two members of memory set. In Experiment 2, subjects detected the change of the shape of a fixation stimulus, which was surrounded by the same alphabets as in Experiment 1. In the search task (Experiment 1), the incr...

  9. Comparison of leaf anatomical characteristics of hibiscus rosa-sinensis grown in faisalabad region

    International Nuclear Information System (INIS)

    Noman, A.; Ali, Q.; Mehmood, T.; Iftikhar, T.; Mahmeed, M.

    2014-01-01

    The genetic potential of different plant species to different environmental conditions differ in relation to different physiological, biochemical and anatomical characteristics. Of these varying attributes leaf anatomical characteristics play most important role for the establishment of that cultivar in varied environmental conditions. So, the present study was conducted to assess the inter-cultivar genetic potential of Hibiscus in relation to leaf anatomical characteristics. To fulfill the study requirements Hibiscus rosa-sinensis and its six cultivars (were well adapted to their specific natural habitat) were collected from different locations of district Faisalabad Pakistan that have great environmental changes round the year. Results showed significant variability among cultivars in relation to analyzed anatomical characteristics. Cultivars Lemon shiffon and Wilder's white emerge more promising among others by possessing more epidermal thickness, increased epidermal cell area, high cortical cell area and incremented stomatal density as compared with other cultivars. On the other hand, cultivars Cooperi alba, Mrs. George Davis and Frank green possessed least cortex cell area, lowest xylem region thickness and minimum phloem region thickness respectively. Overall, it can be concluded that anatomical genetic potential has endorsed cultivars Lemon chiffon and Wilder's white with enormous capability to grow well under variable environments. (author)

  10. The variability of leaf anatomical characteristics of Solanum nigrum L. (Solana-les, Solanaceae from different habitats

    Directory of Open Access Journals (Sweden)

    Krstić Lana N.

    2002-01-01

    Full Text Available In Europe on the whole as well as in Yugoslavia, the most widespread weed species from the genus Solanum is Solanum nigrum L. Since this species inhabits different habitats, it developed several ways of adaptation to environmental conditions. The influence of ecological factors on plant organism and resulting plant adaptations are most evident in leaf morphology and anatomy. Therefore, the anatomical structure of leaves and leaf epidermal tissue of S. nigrum was analyzed and compared among plants that originated from different habitats, in order to determine leaf structural adaptations. S. nigrum lamina has the mesomorphic structure with some xero-heliomorphic adaptations. The differences in stomata number, number of hairs, thickness of lamina, palisade and spongy tissue, as well as the size of mesophyll cells have been noticed. The highest values for most of the parameters have been recorded for the plants from cultivated soil. Largest variations of the examined characters were found for the leaves from ruderal habitats, where environmental conditions are most variable.

  11. Anatomically shaped cranial collimation (ACC) for lateral cephalometric radiography: a technical report.

    Science.gov (United States)

    Hoogeveen, R C; van der Stelt, P F; Berkhout, W E R

    2014-01-01

    Lateral cephalograms in orthodontic practice display an area cranial of the base of the skull that is not required for diagnostic evaluation. Attempts have been made to reduce the radiation dose to the patient using collimators combining the shielding of the areas above the base of the skull and below the mandible. These so-called "wedge-shaped" collimators have not become standard equipment in orthodontic offices, possibly because these collimators were not designed for today's combination panoramic-cephalometric imaging systems. It also may be that the anatomical variability of the area below the mandible makes this area unsuitable for standardized collimation. In addition, a wedge-shaped collimator shields the cervical vertebrae; therefore, assessment of skeletal maturation, which is based on the stage of development of the cervical vertebrae, cannot be performed. In this report, we describe our investigations into constructing a collimator to be attached to the cephalostat and shield the cranial area of the skull, while allowing the visualization of diagnostically relevant structures and markedly reducing the size of the irradiated area. The shape of the area shielded by this "anatomically shaped cranial collimator" (ACC) was based on mean measurements of cephalometric landmarks of 100 orthodontic patients. It appeared that this collimator reduced the area of irradiation by almost one-third without interfering with the imaging system or affecting the quality of the image. Further research is needed to validate the clinical efficacy of the collimator.

  12. Surface display of a massively variable lipoprotein by a Legionella diversity-generating retroelement.

    Science.gov (United States)

    Arambula, Diego; Wong, Wenge; Medhekar, Bob A; Guo, Huatao; Gingery, Mari; Czornyj, Elizabeth; Liu, Minghsun; Dey, Sanghamitra; Ghosh, Partho; Miller, Jeff F

    2013-05-14

    Diversity-generating retroelements (DGRs) are a unique family of retroelements that confer selective advantages to their hosts by facilitating localized DNA sequence evolution through a specialized error-prone reverse transcription process. We characterized a DGR in Legionella pneumophila, an opportunistic human pathogen that causes Legionnaires disease. The L. pneumophila DGR is found within a horizontally acquired genomic island, and it can theoretically generate 10(26) unique nucleotide sequences in its target gene, legionella determinent target A (ldtA), creating a repertoire of 10(19) distinct proteins. Expression of the L. pneumophila DGR resulted in transfer of DNA sequence information from a template repeat to a variable repeat (VR) accompanied by adenine-specific mutagenesis of progeny VRs at the 3'end of ldtA. ldtA encodes a twin-arginine translocated lipoprotein that is anchored in the outer leaflet of the outer membrane, with its C-terminal variable region surface exposed. Related DGRs were identified in L. pneumophila clinical isolates that encode unique target proteins with homologous VRs, demonstrating the adaptability of DGR components. This work characterizes a DGR that diversifies a bacterial protein and confirms the hypothesis that DGR-mediated mutagenic homing occurs through a conserved mechanism. Comparative bioinformatics predicts that surface display of massively variable proteins is a defining feature of a subset of bacterial DGRs.

  13. COMICS: Cartoon Visualization of Omics Data in Spatial Context Using Anatomical Ontologies.

    Science.gov (United States)

    Travin, Dmitrii; Popov, Iaroslav; Guler, Arzu Tugce; Medvedev, Dmitry; van der Plas-Duivesteijn, Suzanne; Varela, Monica; Kolder, Iris C R M; Meijer, Annemarie H; Spaink, Herman P; Palmblad, Magnus

    2018-01-05

    COMICS is an interactive and open-access web platform for integration and visualization of molecular expression data in anatomograms of zebrafish, carp, and mouse model systems. Anatomical ontologies are used to map omics data across experiments and between an experiment and a particular visualization in a data-dependent manner. COMICS is built on top of several existing resources. Zebrafish and mouse anatomical ontologies with their controlled vocabulary (CV) and defined hierarchy are used with the ontoCAT R package to aggregate data for comparison and visualization. Libraries from the QGIS geographical information system are used with the R packages "maps" and "maptools" to visualize and interact with molecular expression data in anatomical drawings of the model systems. COMICS allows users to upload their own data from omics experiments, using any gene or protein nomenclature they wish, as long as CV terms are used to define anatomical regions or developmental stages. Common nomenclatures such as the ZFIN gene names and UniProt accessions are provided additional support. COMICS can be used to generate publication-quality visualizations of gene and protein expression across experiments. Unlike previous tools that have used anatomical ontologies to interpret imaging data in several animal models, including zebrafish, COMICS is designed to take spatially resolved data generated by dissection or fractionation and display this data in visually clear anatomical representations rather than large data tables. COMICS is optimized for ease-of-use, with a minimalistic web interface and automatic selection of the appropriate visual representation depending on the input data.

  14. Changes of wood anatomical characters of selected species of Araucaria- during artificial charring - implications for palaeontology

    Directory of Open Access Journals (Sweden)

    Isa Carla Osterkamp

    2017-11-01

    Full Text Available ABSTRACT Charcoal is widely accepted as evidence of the occurrence of palaeo-wildfire. Although fossil charcoal remains have been used in many studies, investigation into the anatomical changes occurring during charring are few. The present study analyses changes in selected anatomical characters during artificial charring of modern wood of three species of the genus Araucaria (i.e. Araucaria angustifolia, Araucaria bidwillii and Araucaria columnaris. Wood samples of the studied species was charred under controlled conditions at varying temperatures. Measurements of anatomical features of uncharred wood and artificial charcoal were statistically analysed. The anatomical changes were statistically correlated with charring temperatures and most of the parameters showed marked decreases with increasing charring temperature. Compared to the intrinsic variability in anatomical features, both within and between growth rings of an individual plant, the changes induced by temperature account only for a comparatively small percentage of the observed variability. Regarding Araucaria charcoal, it seems possible that at least general taxonomic and palaeoenvironmental implications can be drawn from such material. However, it is not clear so far whether these results and interpretations based on only three taxa, can be generalized for the entire family and anatomically similar fossil taxa or not.

  15. Wood anatomical and chemical properties related to the pulpability ...

    African Journals Online (AJOL)

    Eucalyptus globulus is one of the most important hardwood species used by the pulp and paper industry due to its high pulp yield, high wood density, excellent fibre quality and good handsheet properties. However, the wood is a highly variable and complex material that has different chemical, physical and anatomical ...

  16. Anatomical Variability of the Posterior Communicating Artery.

    Science.gov (United States)

    Gunnal, Sandhya Arvind; Farooqui, Mujibuddin S; Wabale, Rajendra N

    2018-01-01

    Although posterior communicating artery (PCoA) is a smaller branch of the internal carotid artery, it gives the main contribution in the formation of circle of Willis (CW) by communicating with the internal carotid arterial system and the vertebro-basilar arterial system. The size of PCoA varies frequently. The present work aims to study the PCoA regarding its morphology, morphometry, and symmetry. This study was conducted on 170 human cadaveric brains. Brains were dissected carefully and delicately to expose all components of CW, especially PCoA. Morphological variations of PCoA were noted along with its morphometry and symmetry. Morphological variations of PCoA were aplasia (3.52%), hypoplasia (25.29%), fenestration (0.58%), and persistent fetal pattern (16.47%). In the present study, we found the five different types of terminations of PCoA. Type I termination was the most common type, seen in 92.94% of cases, Type II termination was seen in 1.17%, Type III and Type IV terminations both were seen in 0.58%, and Type V was seen in 1.17%. The mean length of PCoA was 15.9 mm and 15.3 mm on the right and left sides, respectively. The mean diameter of PCoA was 2.1 mm and 1.9 mm on the right and left sides, respectively. Symmetry of PCoA was seen in 65.29% and asymmetric PCoA was seen in 34.70% of cases. The present study provides the complete description of PCoA regarding its morphology, symmetry, and morphometry. Awareness of these anatomical variations is important in neurovascular procedures.

  17. Feature-based morphometry: discovering group-related anatomical patterns.

    Science.gov (United States)

    Toews, Matthew; Wells, William; Collins, D Louis; Arbel, Tal

    2010-02-01

    This paper presents feature-based morphometry (FBM), a new fully data-driven technique for discovering patterns of group-related anatomical structure in volumetric imagery. In contrast to most morphometry methods which assume one-to-one correspondence between subjects, FBM explicitly aims to identify distinctive anatomical patterns that may only be present in subsets of subjects, due to disease or anatomical variability. The image is modeled as a collage of generic, localized image features that need not be present in all subjects. Scale-space theory is applied to analyze image features at the characteristic scale of underlying anatomical structures, instead of at arbitrary scales such as global or voxel-level. A probabilistic model describes features in terms of their appearance, geometry, and relationship to subject groups, and is automatically learned from a set of subject images and group labels. Features resulting from learning correspond to group-related anatomical structures that can potentially be used as image biomarkers of disease or as a basis for computer-aided diagnosis. The relationship between features and groups is quantified by the likelihood of feature occurrence within a specific group vs. the rest of the population, and feature significance is quantified in terms of the false discovery rate. Experiments validate FBM clinically in the analysis of normal (NC) and Alzheimer's (AD) brain images using the freely available OASIS database. FBM automatically identifies known structural differences between NC and AD subjects in a fully data-driven fashion, and an equal error classification rate of 0.80 is achieved for subjects aged 60-80 years exhibiting mild AD (CDR=1). Copyright (c) 2009 Elsevier Inc. All rights reserved.

  18. To 'display' or not to 'display'- that is the peptide

    CSIR Research Space (South Africa)

    Crampton, Michael C

    2008-11-01

    Full Text Available eukaryotic and prokaryotic systems but has mainly focused around phages (Etz et al, 2001), yeast (Kondo and Ueda, 2004) and bacteria (Lee et al 2003). The central variable domain of the FliC protein is dispensable and can be used for the insertion and display...

  19. Morpho-anatomical structure of the leaves of Festuca trachyphylla (Hack. Krajina in the ecological aspect

    Directory of Open Access Journals (Sweden)

    Agnieszka Dąbrowska

    2012-03-01

    Full Text Available Festuca trachyphylla(Hack. Krajina is a morphologically variable species common in warm and dry habitats in various communities: xerothermic grasslands, dry meadows, sand dunes, scrub and well-lighted forest. The aim of this study was to determine the limits of morphological and anatomical trait variability of F. rachyphylla leaves. The study was conducted in 24 sub-populations (N-432 individuals in the Lublin Upland, southeastern Poland. Plants in two localities were investigated: in calcium carbonate-rich xerothermic grasslands and on sand dunes. Variability of the F. trachyphylla leaf blades was demonstrated to be dependent on thehabitat type. The following morphological and anatomical traits: the length of the leaf, width of the cauline leaf, number of ribs in theleaf, length of the cauline leaf, length of hair in the leaf, colour of the leaf, hairiness of the upper part leaf, cross-section of the leaf, and distribution of the sclerenchymatous tissue in the leaf blade exhibited high variability.

  20. An anatomical and functional topography of human auditory cortical areas

    Directory of Open Access Journals (Sweden)

    Michelle eMoerel

    2014-07-01

    Full Text Available While advances in magnetic resonance imaging (MRI throughout the last decades have enabled the detailed anatomical and functional inspection of the human brain non-invasively, to date there is no consensus regarding the precise subdivision and topography of the areas forming the human auditory cortex. Here, we propose a topography of the human auditory areas based on insights on the anatomical and functional properties of human auditory areas as revealed by studies of cyto- and myelo-architecture and fMRI investigations at ultra-high magnetic field (7 Tesla. Importantly, we illustrate that - whereas a group-based approach to analyze functional (tonotopic maps is appropriate to highlight the main tonotopic axis - the examination of tonotopic maps at single subject level is required to detail the topography of primary and non-primary areas that may be more variable across subjects. Furthermore, we show that considering multiple maps indicative of anatomical (i.e. myelination as well as of functional properties (e.g. broadness of frequency tuning is helpful in identifying auditory cortical areas in individual human brains. We propose and discuss a topography of areas that is consistent with old and recent anatomical post mortem characterizations of the human auditory cortex and that may serve as a working model for neuroscience studies of auditory functions.

  1. New developments in flexible cholesteric liquid crystal displays

    Science.gov (United States)

    Schneider, Tod; Davis, Donald J.; Franklin, Sean; Venkataraman, Nithya; McDaniel, Diaz; Nicholson, Forrest; Montbach, Erica; Khan, Asad; Doane, J. William

    2007-02-01

    Flexible Cholesteric liquid crystal displays have been rapidly maturing into a strong contender in the flexible display market. Encapsulation of the Cholesteric liquid crystal permits the use of flexible plastic substrates and roll-to-roll production. Recent advances include ultra-thin displays, laser-cut segmented displays of variable geometry, and smart card applications. Exciting technologies such as simultaneous laser-edge sealing and singulation enable high volume production, excellent quality control and non-traditional display geometries and formats.

  2. Probabilistic anatomical labeling of brain structures using statistical probabilistic anatomical maps

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Dong Soo; Lee, Byung Il; Lee, Jae Sung; Shin, Hee Won; Chung, June Key; Lee, Myung Chul

    2002-01-01

    The use of statistical parametric mapping (SPM) program has increased for the analysis of brain PET and SPECT images. Montreal neurological institute (MNI) coordinate is used in SPM program as a standard anatomical framework. While the most researchers look up Talairach atlas to report the localization of the activations detected in SPM program, there is significant disparity between MNI templates and Talairach atlas. That disparity between Talairach and MNI coordinates makes the interpretation of SPM result time consuming, subjective and inaccurate. The purpose of this study was to develop a program to provide objective anatomical information of each x-y-z position in ICBM coordinate. Program was designed to provide the anatomical information for the given x-y-z position in MNI coordinate based on the statistical probabilistic anatomical map (SPAM) images of ICBM. When x-y-z position was given to the program, names of the anatomical structures with non-zero probability and the probabilities that the given position belongs to the structures were tabulated. The program was coded using IDL and JAVA language for the easy transplantation to any operating system or platform. Utility of this program was shown by comparing the results of this program to those of SPM program. Preliminary validation study was performed by applying this program to the analysis of PET brain activation study of human memory in which the anatomical information on the activated areas are previously known. Real time retrieval of probabilistic information with 1 mm spatial resolution was archived using the programs. Validation study showed the relevance of this program: probability that the activated area for memory belonged to hippocampal formation was more than 80%. These programs will be useful for the result interpretation of the image analysis performed on MNI coordinate, as done in SPM program

  3. Social variables exert selective pressures in the evolution and form of primate mimetic musculature.

    Science.gov (United States)

    Burrows, Anne M; Li, Ly; Waller, Bridget M; Micheletta, Jerome

    2016-04-01

    Mammals use their faces in social interactions more so than any other vertebrates. Primates are an extreme among most mammals in their complex, direct, lifelong social interactions and their frequent use of facial displays is a means of proximate visual communication with conspecifics. The available repertoire of facial displays is primarily controlled by mimetic musculature, the muscles that move the face. The form of these muscles is, in turn, limited by and influenced by phylogenetic inertia but here we use examples, both morphological and physiological, to illustrate the influence that social variables may exert on the evolution and form of mimetic musculature among primates. Ecomorphology is concerned with the adaptive responses of morphology to various ecological variables such as diet, foliage density, predation pressures, and time of day activity. We present evidence that social variables also exert selective pressures on morphology, specifically using mimetic muscles among primates as an example. Social variables include group size, dominance 'style', and mating systems. We present two case studies to illustrate the potential influence of social behavior on adaptive morphology of mimetic musculature in primates: (1) gross morphology of the mimetic muscles around the external ear in closely related species of macaque (Macaca mulatta and Macaca nigra) characterized by varying dominance styles and (2) comparative physiology of the orbicularis oris muscle among select ape species. This muscle is used in both facial displays/expressions and in vocalizations/human speech. We present qualitative observations of myosin fiber-type distribution in this muscle of siamang (Symphalangus syndactylus), chimpanzee (Pan troglodytes), and human to demonstrate the potential influence of visual and auditory communication on muscle physiology. In sum, ecomorphologists should be aware of social selective pressures as well as ecological ones, and that observed morphology might

  4. Anatomical imaging for radiotherapy

    International Nuclear Information System (INIS)

    Evans, Philip M

    2008-01-01

    scans is taken on different days. Both allow planning to account for variability intrinsic to the patient. Treatment verification has been carried out using a variety of technologies including: MV portal imaging, kV portal/fluoroscopy, MVCT, conebeam kVCT, ultrasound and optical surface imaging. The various methods have their pros and cons. The four x-ray methods involve an extra radiation dose to normal tissue. The portal methods may not generally be used to visualize soft tissue, consequently they are often used in conjunction with implanted fiducial markers. The two CT-based methods allow measurement of inter-fraction variation only. Ultrasound allows soft-tissue measurement with zero dose but requires skilled interpretation, and there is evidence of systematic differences between ultrasound and other data sources, perhaps due to the effects of the probe pressure. Optical imaging also involves zero dose but requires good correlation between the target and the external measurement and thus is often used in conjunction with an x-ray method. The use of anatomical imaging in radiotherapy allows treatment uncertainties to be determined. These include errors between the mean position at treatment and that at planning (the systematic error) and the day-to-day variation in treatment set-up (the random error). Positional variations may also be categorized in terms of inter- and intra-fraction errors. Various empirical treatment margin formulae and intervention approaches exist to determine the optimum strategies for treatment in the presence of these known errors. Other methods exist to try to minimize error margins drastically including the currently available breath-hold techniques and the tracking methods which are largely in development. This paper will review anatomical imaging techniques in radiotherapy and how they are used to boost the therapeutic benefit of the treatment. (topical review)

  5. CT virtual endoscopy: a study of the capability to display the structures and abnormalities in nasal cavity

    International Nuclear Information System (INIS)

    Han Ping; Brambs, H.J.; Sokiranski, R.

    1999-01-01

    Objective: To evaluate display ability of virtual endoscopy and its clinical application in comparison with fiberoptic nasal endoscopy. Methods: 11 patients (22 nasal cavities) were examined by virtual endoscopy after axial spiral CT scanning was performed. Virtual endoscopy was performed by Explorer software package in a computer workstation. 9 patients (18 nasal cavities) underwent fiberoptic endoscopy. Results: Virtual endoscopy could clearly demonstrate the anatomical structures in nasal cavity, septal deviation, nasal meatus narrowing and obstruction, turbinate hyperplasia, and pathological masses larger than 3 mm in diameter. However, 'false adhesions' may appear in virtual endoscopy. The main limitation of virtual endoscopy was inability to evaluate mucosa and lack of histological diagnosis. Conclusions: Virtual endoscopy is a new, non-invasive method for demonstrating anatomical structures and diseases in nasal cavity. Its display ability is comparable with fiberoptic nasal endoscopy and is a supplement to fiberoptic nasal endoscopy

  6. Posterolateral supporting structures of the knee: findings on anatomic dissection, anatomic slices and MR images

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, M. de; Shahabpour, M.; Vanderdood, K.; Ridder, F. de; Osteaux, M. [Dept. of Radiology, Free Univ. Brussels (Belgium); Roy, F. van [Dept. of Experimental Anatomy, Free Univ. Brussels (Belgium)

    2001-11-01

    In this article we study the ligaments and tendons of the posterolateral corner of the knee by anatomic dissection, MR-anatomic correlation, and MR imaging. The posterolateral aspect of two fresh cadaveric knee specimens was dissected. The MR-anatomic correlation was performed in three other specimens. The MR images of 122 patients were reviewed and assessed for the visualization of different posterolateral structures. Anatomic dissection and MR-anatomic correlation demonstrated the lateral collateral, fabellofibular, and arcuate ligaments, as well as the biceps and popliteus tendons. On MR images of patients the lateral collateral ligament was depicted in all cases. The fabellofibular, arcuate, and popliteofibular ligaments were visualized in 33, 25, and 38% of patients, respectively. Magnetic resonance imaging allows a detailed appreciation of the posterolateral corner of the knee. (orig.)

  7. Benchmarking Academic Anatomic Pathologists: The Association of Pathology Chairs Survey.

    Science.gov (United States)

    Ducatman, Barbara S; Parslow, Tristram

    2016-01-01

    The most common benchmarks for faculty productivity are derived from Medical Group Management Association (MGMA) or Vizient-AAMC Faculty Practice Solutions Center ® (FPSC) databases. The Association of Pathology Chairs has also collected similar survey data for several years. We examined the Association of Pathology Chairs annual faculty productivity data and compared it with MGMA and FPSC data to understand the value, inherent flaws, and limitations of benchmarking data. We hypothesized that the variability in calculated faculty productivity is due to the type of practice model and clinical effort allocation. Data from the Association of Pathology Chairs survey on 629 surgical pathologists and/or anatomic pathologists from 51 programs were analyzed. From review of service assignments, we were able to assign each pathologist to a specific practice model: general anatomic pathologists/surgical pathologists, 1 or more subspecialties, or a hybrid of the 2 models. There were statistically significant differences among academic ranks and practice types. When we analyzed our data using each organization's methods, the median results for the anatomic pathologists/surgical pathologists general practice model compared to MGMA and FPSC results for anatomic and/or surgical pathology were quite close. Both MGMA and FPSC data exclude a significant proportion of academic pathologists with clinical duties. We used the more inclusive FPSC definition of clinical "full-time faculty" (0.60 clinical full-time equivalent and above). The correlation between clinical full-time equivalent effort allocation, annual days on service, and annual work relative value unit productivity was poor. This study demonstrates that effort allocations are variable across academic departments of pathology and do not correlate well with either work relative value unit effort or reported days on service. Although the Association of Pathology Chairs-reported median work relative value unit productivity

  8. Reliable cloning of functional antibody variable domains from hybridomas and spleen cell repertoires employing a reengineered phage display system.

    Science.gov (United States)

    Krebber, A; Bornhauser, S; Burmester, J; Honegger, A; Willuda, J; Bosshard, H R; Plückthun, A

    1997-02-14

    A prerequisite for the use of recombinant antibody technologies starting from hybridomas or immune repertoires is the reliable cloning of functional immunoglobulin genes. For this purpose, a standard phage display system was optimized for robustness, vector stability, tight control of scFv-delta geneIII expression, primer usage for PCR amplification of variable region genes, scFv assembly strategy and subsequent directional cloning using a single rare cutting restriction enzyme. This integrated cloning, screening and selection system allowed us to rapidly obtain antigen binding scFvs derived from spleen-cell repertoires of mice immunized with ampicillin as well as from all hybridoma cell lines tested to date. As representative examples, cloning of monoclonal antibodies against a his tag, leucine zippers, the tumor marker EGP-2 and the insecticide DDT is presented. Several hybridomas whose genes could not be cloned in previous experimental setups, but were successfully obtained with the present system, expressed high amounts of aberrant heavy and light chain mRNAs, which were amplified by PCR and greatly exceeded the amount of binding antibody sequences. These contaminating variable region genes were successfully eliminated by employing the optimized phage display system, thus avoiding time consuming sequencing of non-binding scFv genes. To maximize soluble expression of functional scFvs subsequent to cloning, a compatible vector series to simplify modification, detection, multimerization and rapid purification of recombinant antibody fragments was constructed.

  9. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  10. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  11. A quantitative comparison of the electrical and anatomical definition of the pulmonary vein ostium.

    Science.gov (United States)

    Spies, Florian; Kühne, Michael; Reichlin, Tobias; Osswald, Stefan; Sticherling, Christian; Knecht, Sven

    2017-11-01

    Anatomically guided pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. However, the position where to confirm electrical isolation is ill-defined. The aim of the current study was to quantify the relationship between the anatomical and electrical definition of the pulmonary vein ostium. We analyzed 20 patients with paroxysmal AF undergoing PVI using radiofrequency energy and an electroanatomical mapping system. The anatomical ostium was defined based on the geometry obtained from preprocedural magnetic resonance imaging and computed tomography. The electrical ostium was defined at the position with a far-field atrial signal preceding a sharp pulmonary vein (PV) signal without any isoelectric interval in between. The electrically defined ostia were 8.4 ± 4.7 mm more distal in the PV compared to the anatomically defined ostia. The distances varied considerably between the four PVs and were 10.5 ± 6.5 mm, 7.4 ± 4.3 mm, 5.3 ± 4.0 mm, and 8.3 ± 3.4 mm for the left superior, left inferior, right superior, and right inferior PVs, respectively (P  =  0.009). The position of the electrical and anatomical ostium differs markedly. The site of the electrical ostium is variable within the PV but always more distal in the PV compared to the site of the anatomical ostium. © 2017 Wiley Periodicals, Inc.

  12. Radial force distribution changes associated with tangential force production in cylindrical grasping, and the importance of anatomical registration.

    Science.gov (United States)

    Pataky, Todd C; Slota, Gregory P; Latash, Mark L; Zatsiorsky, Vladimir M

    2012-01-10

    Radial force (F(r)) distributions describe grip force coordination about a cylindrical object. Recent studies have employed only explicit F(r) tasks, and have not normalized for anatomical variance when considering F(r) distributions. The goals of the present study were (i) to explore F(r) during tangential force production tasks, and (ii) to examine the extent to which anatomical registration (i.e. spatial normalization of anatomically analogous structures) could improve signal detectability in F(r) data. Twelve subjects grasped a vertically oriented cylindrical handle (diameter=6 cm) and matched target upward tangential forces of 10, 20, and 30 N. F(r) data were measured using a flexible pressure mat with an angular resolution of 4.8°, and were registered using piecewise-linear interpolation between five manually identified points-of-interest. Results indicate that F(r) was primarily limited to three contact regions: the distal thumb, the distal fingers, and the fingers' metatacarpal heads, and that, while increases in tangential force caused significant increases in F(r) for these regions, they did not significantly affect the F(r) distribution across the hand. Registration was found to substantially reduce between-subject variability, as indicated by both accentuated F(r) trends, and amplification of the test statistic. These results imply that, while subjects focus F(r) primarily on three anatomical regions during cylindrical grasp, inter-subject anatomical differences introduce a variability that, if not corrected for via registration, may compromise one's ability to draw anatomically relevant conclusions from grasping force data. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Array display tool ADT reference manual. Version 1.2

    International Nuclear Information System (INIS)

    Evans, K. Jr.

    1995-12-01

    Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position along with symbols for the major elements of the lattice. There can be several display areas, but at most one zoom area. When the screen is resized these areas change size proportionally. There are a number of options in the View Menu to change the way the values are displayed. It is also possible via the Options Menu to: (1) Store the current values internally. (2) Store the values from a snapshot file internally. (3) Display one of the stored sets of values along with the current values. (4) Display the difference of the current values with one of the stored sets of values. (5) Write the current values to a snapshot file. There are several (currently 5) slots in which you can store values internally. In addition you can display the values with specified reference values subtracted

  14. Outcome-based anatomic criteria for defining the hostile aortic neck.

    Science.gov (United States)

    Jordan, William D; Ouriel, Kenneth; Mehta, Manish; Varnagy, David; Moore, William M; Arko, Frank R; Joye, James; de Vries, Jean-Paul P M

    2015-06-01

    There is abundant evidence linking hostile proximal aortic neck anatomy to poor outcome after endovascular aortic aneurysm repair (EVAR), yet the definition of hostile anatomy varies from study to study. This current analysis was undertaken to identify anatomic criteria that are most predictive of success or failure at the aortic neck after EVAR. The study group comprised 221 patients in the Aneurysm Treatment using the Heli-FX Aortic Securement System Global Registry (ANCHOR) clinical trial, a population enriched with patients with challenging aortic neck anatomy and failure of sealing. Imaging protocols were not protocol specified but were performed according to the institution's standard of care. Core laboratory analysis assessed the three-dimensional centerline-reformatted computed tomography scans. Failure at the aortic neck was defined by type Ia endoleak occurring at the time of the initial endograft implantation or during follow-up. Receiver operating characteristic curve analysis was used to assess the value of each anatomic measure in the classification of aortic neck success and failure and to identify optimal thresholds of discrimination. Binary logistic regression was performed after excluding highly intercorrelated variables, creating a final model with significant predictors of outcome after EVAR. Among the 221 patients, 121 (54.8%) remained free of type Ia endoleak and 100 (45.2%) did not. Type Ia endoleaks presented immediately after endograft deployment in 58 (58.0%) or during follow-up in 42 (42.0%). Receiver operating characteristic curve analysis identified 12 variables where the classification of patients with type Ia endoleak was significantly more accurate than chance alone. Increased aortic neck diameter at the lowest renal artery (P = .013) and at 5 mm (P = .008), 10 mm (P = .008), and 15 mm (P = .010) distally; aneurysm sac diameter (P = .001), common iliac artery diameters (right, P = .012; left, P = .032), and a conical (P = .049) neck

  15. The importance of being Florentine: a journey around the world for wax anatomical Venuses.

    Science.gov (United States)

    de Ceglia, Francesco Paolo

    2011-01-01

    This article reconstructs the 19th century history of events regarding a few female wax anatomical models made in Florence. More or less faithful copies of those housed in Florence's Museum of Physics and Natural History, these models were destined for display in temporary exhibitions. In their travels through Europe and the United States, they transformed the expression "Florentine Venus" into a sort of brand name used to label and offer respectability to pieces of widely varying quality.

  16. DP: Parameter Display Page Program

    International Nuclear Information System (INIS)

    Anderson, M.

    1994-01-01

    The Parameter Display Page program (DP) is a Motif/X11-based program to allow easily configured, dynamic device and process variable monitoring and manipulation in the EPICS environment. DP provides a tabular data format for interactive viewing and manipulation of device and process variable statistics, as well as formatted PostScript output to files and printers. DP understands and operates in two (unfortunately disjoint at this time) namespaces in the EPICS environment ''devices'' and ''process variables''. The higher level namespace of devices includes Composite and Atomic Devices registered via the Device Access server; the lower level (flat) namespace is that of normal Process Variables accessible via Channel Access

  17. The anatomic basis of lingual nerve trauma associated with inferior alveolar block injections.

    Science.gov (United States)

    Morris, Christopher D; Rasmussen, Jared; Throckmorton, Gaylord S; Finn, Richard

    2010-11-01

    This study describes the anatomic variability in the position of the lingual nerve in the pterygomandibular space, the location of the inferior alveolar nerve block injection. Simulated standard landmark-based inferior alveolar nerve blocks were administered to 44 fixed sagitally bisected cadaver heads. Measurements were made of the diameter of the nerves and distances between the needle and selected anatomic landmarks and the nerves. Of 44 simulated injections, 42 (95.5%) passed lateral to the lingual nerve, 7 (16%) passed within 0.1 mm of the nerve, and 2 (4.5%) penetrated the nerve. The position of the lingual nerve relative to bony landmarks within the interpterygoid fascia was highly variable. Variation in the position of the lingual nerve is an important contributor to lingual nerve trauma during inferior alveolar block injections. This factor should be an important part of preoperative informed consent. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Anatomical curve identification

    Science.gov (United States)

    Bowman, Adrian W.; Katina, Stanislav; Smith, Joanna; Brown, Denise

    2015-01-01

    Methods for capturing images in three dimensions are now widely available, with stereo-photogrammetry and laser scanning being two common approaches. In anatomical studies, a number of landmarks are usually identified manually from each of these images and these form the basis of subsequent statistical analysis. However, landmarks express only a very small proportion of the information available from the images. Anatomically defined curves have the advantage of providing a much richer expression of shape. This is explored in the context of identifying the boundary of breasts from an image of the female torso and the boundary of the lips from a facial image. The curves of interest are characterised by ridges or valleys. Key issues in estimation are the ability to navigate across the anatomical surface in three-dimensions, the ability to recognise the relevant boundary and the need to assess the evidence for the presence of the surface feature of interest. The first issue is addressed by the use of principal curves, as an extension of principal components, the second by suitable assessment of curvature and the third by change-point detection. P-spline smoothing is used as an integral part of the methods but adaptations are made to the specific anatomical features of interest. After estimation of the boundary curves, the intermediate surfaces of the anatomical feature of interest can be characterised by surface interpolation. This allows shape variation to be explored using standard methods such as principal components. These tools are applied to a collection of images of women where one breast has been reconstructed after mastectomy and where interest lies in shape differences between the reconstructed and unreconstructed breasts. They are also applied to a collection of lip images where possible differences in shape between males and females are of interest. PMID:26041943

  19. Evaluation of tactual displays for flight control

    Science.gov (United States)

    Levison, W. H.; Tanner, R. B.; Triggs, T. J.

    1973-01-01

    Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

  20. [Establishment of anatomical terminology in Japan].

    Science.gov (United States)

    Shimada, Kazuyuki

    2008-12-01

    The history of anatomical terminology in Japan began with the publication of Waran Naikei Ihan-teimŏ in 1805 and Chŏtei Kaitai Shinsho in 1826. Although the establishment of Japanese anatomical terminology became necessary during the Meiji era when many western anatomy books imported into Janan were translated, such terminology was not unified during this period and varied among translators. In 1871, Tsukumo Ono's Kaibŏgaku Gosen was published by the Ministry of Education. Although this book is considered to be the first anatomical glossary terms in Japan, its contents were incomplete. Overseas, the German Anatomical Society established a unified anatomical terminology in 1895 called the Basle Nomina Anatomica (B.N.A.). Based on this development, Kaibŏgaku Meishŭ which follows the BNA, by Buntarŏ Suzuki was published in 1905. With the subsequent establishment in 1935 of Jena Nomina Anatomica (J.N.A.), the unification of anatomical terminology was also accelerated in Japan, leading to the further development of terminology.

  1. Construction of patient specific atlases from locally most similar anatomical pieces

    Science.gov (United States)

    Ramus, Liliane; Commowick, Olivier; Malandain, Grégoire

    2010-01-01

    Radiotherapy planning requires accurate delineations of the critical structures. To avoid manual contouring, atlas-based segmentation can be used to get automatic delineations. However, the results strongly depend on the chosen atlas, especially for the head and neck region where the anatomical variability is high. To address this problem, atlases adapted to the patient’s anatomy may allow for a better registration, and already showed an improvement in segmentation accuracy. However, building such atlases requires the definition of a criterion to select among a database the images that are the most similar to the patient. Moreover, the inter-expert variability of manual contouring may be high, and therefore bias the segmentation if selecting only one image for each region. To tackle these issues, we present an original method to design a piecewise most similar atlas. Given a query image, we propose an efficient criterion to select for each anatomical region the K most similar images among a database by considering local volume variations possibly induced by the tumor. Then, we present a new approach to combine the K images selected for each region into a piecewise most similar template. Our results obtained with 105 CT images of the head and neck show that our method reduces the over-segmentation seen with an average atlas while being robust to inter-expert manual segmentation variability. PMID:20879395

  2. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    Science.gov (United States)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, pscore. The reproduction of spinous processes (rτ=0.67, pscore. Conclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  3. Analysis of visual coding variables on CRT generated displays

    International Nuclear Information System (INIS)

    Blackman, H.S.; Gilmore, W.E.

    1985-01-01

    Cathode ray tube generated safety parameter display systems in a nuclear power plant control room situation have been found to be improved in effectiveness when color coding is employed. Research has indicated strong support for graphic coding techniques particularly in redundant coding schemes. In addition, findings on pictographs, as applied in coding schemes, indicate the need for careful application and for further research in the development of a standardized set of symbols

  4. Learning-based stochastic object models for characterizing anatomical variations

    Science.gov (United States)

    Dolly, Steven R.; Lou, Yang; Anastasio, Mark A.; Li, Hua

    2018-03-01

    It is widely known that the optimization of imaging systems based on objective, task-based measures of image quality via computer-simulation requires the use of a stochastic object model (SOM). However, the development of computationally tractable SOMs that can accurately model the statistical variations in human anatomy within a specified ensemble of patients remains a challenging task. Previously reported numerical anatomic models lack the ability to accurately model inter-patient and inter-organ variations in human anatomy among a broad patient population, mainly because they are established on image data corresponding to a few of patients and individual anatomic organs. This may introduce phantom-specific bias into computer-simulation studies, where the study result is heavily dependent on which phantom is used. In certain applications, however, databases of high-quality volumetric images and organ contours are available that can facilitate this SOM development. In this work, a novel and tractable methodology for learning a SOM and generating numerical phantoms from a set of volumetric training images is developed. The proposed methodology learns geometric attribute distributions (GAD) of human anatomic organs from a broad patient population, which characterize both centroid relationships between neighboring organs and anatomic shape similarity of individual organs among patients. By randomly sampling the learned centroid and shape GADs with the constraints of the respective principal attribute variations learned from the training data, an ensemble of stochastic objects can be created. The randomness in organ shape and position reflects the learned variability of human anatomy. To demonstrate the methodology, a SOM of an adult male pelvis is computed and examples of corresponding numerical phantoms are created.

  5. Application of Variable Life Adjusted Displays (VLAD on Victorian Admitted Episodes Dataset (VAED

    Directory of Open Access Journals (Sweden)

    Andrianopoulos Nick

    2012-08-01

    Full Text Available Abstract Background The need to improve patient safety has been identified as a major priority for health reform in developed countries, including Australia. We investigated the implementation and appropriateness of Variable Life Adjusted Displays as a quality control procedure to monitor “in-control” versus “out-of-control” processes in Victorian public hospitals. Methods Victorian Admitted Episode Data from Department of Human Services, Victoria for 2004–7 were used. The VLAD is a plot of a cumulative sum of the difference in expected outcome (range 0–1 and observed outcome (0 or 1 for sequential separations. Three outcomes were assessed: in-hospital mortality for acute myocardial infarction, stroke and heart failure. Logistic regression was used to obtain a realistic measure of expected mortality over the period 2004–5, adjusting for covariates and comorbidities, to estimate expected mortality risk for the separations between 2005–7. VLAD were plotted for the years 2005–7, by the 11 hospitals with the highest frequency of separations. Signalling limits for 30%, 50% and 75% risk decrease and risk increase were determined and plotted for each VLAD utilizing risk-adjusted cumulative sum techniques. This is a likelihood-ratio test statistic for signalling. If the VLAD signalled by intersecting with a limit, the limit was reset. Results The three logit models displayed reasonable fit to the observed data. There were n = 2999 separations in the AMI model, n = 3598 in the HF model and n = 1922 in the stroke model. The number of separations plotted by VLAD ranged from n = 126 to n = 648. No signals were observed in 64%, 55% and 18% of VLAD for AMI, HF and stroke respectively. For AMI and HF 9% of hospitals signalled at least once for each of 30%, 50% and 75% risk increase, whereas this was 45% for stroke. Hospitals signalling at least once for risk decrease ranged from 18% to 36% across the levels of risk and

  6. Transcriptomic and anatomical complexity of primary, seminal, and crown roots highlight root type-specific functional diversity in maize (Zea mays L.).

    Science.gov (United States)

    Tai, Huanhuan; Lu, Xin; Opitz, Nina; Marcon, Caroline; Paschold, Anja; Lithio, Andrew; Nettleton, Dan; Hochholdinger, Frank

    2016-02-01

    Maize develops a complex root system composed of embryonic and post-embryonic roots. Spatio-temporal differences in the formation of these root types imply specific functions during maize development. A comparative transcriptomic study of embryonic primary and seminal, and post-embryonic crown roots of the maize inbred line B73 by RNA sequencing along with anatomical studies were conducted early in development. Seminal roots displayed unique anatomical features, whereas the organization of primary and crown roots was similar. For instance, seminal roots displayed fewer cortical cell files and their stele contained more meta-xylem vessels. Global expression profiling revealed diverse patterns of gene activity across all root types and highlighted the unique transcriptome of seminal roots. While functions in cell remodeling and cell wall formation were prominent in primary and crown roots, stress-related genes and transcriptional regulators were over-represented in seminal roots, suggesting functional specialization of the different root types. Dynamic expression of lignin biosynthesis genes and histochemical staining suggested diversification of cell wall lignification among the three root types. Our findings highlight a cost-efficient anatomical structure and a unique expression profile of seminal roots of the maize inbred line B73 different from primary and crown roots. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  7. Anatomical Variations of Brachial Artery - Its Morphology, Embryogenesis and Clinical Implications

    Science.gov (United States)

    KS, Siddaraju; Venumadhav, Nelluri; Sharma, Ashish; Kumar, Neeraj

    2014-01-01

    Background: Accurate knowledge of variation pattern of the major arteries of upper limb is of considerable practical importance in the conduct of reparative surgery in the arm, forearm and hand however brachial artery and its terminal branches variations are less common. Aim: Accordingly the present study was designed to evaluate the anatomical variations of the brachial artery and its morphology, embryogenesis and clinical implications. Materials and Methods: In an anatomical study 140 upper limb specimens of 70 cadavers (35 males and 35 females) were used and anatomical variations of the brachial artery have been documented. Results: Accessory brachial artery was noted in eight female cadavers (11.43%). Out of eight cadavers in three cadavers (4.29%) an unusual bilateral accessory brachial artery arising from the axillary artery and it is continuing in the forearm as superficial accessory ulnar artery was noted. Rare unusual variant unilateral accessory brachial artery and its reunion with the main brachial artery in the cubital fossa and its variable course in relation to the musculocutaneous nerve and median nerve were also noted in five cadavers (7.14%). Conclusion: As per our knowledge such anatomical variations of brachial artery and its terminal branches with their relation to the surrounding structures are not reported in the modern medical literature. An awareness of such a presence is valuable for the surgeons and radiologists in evaluation of angiographic images, vascular and re-constructive surgery or appropriate treatment for compressive neuropathies. PMID:25653931

  8. Analysis of the variability of occlusal function patterns in masticatory movement--use of the GEMAS software.

    Science.gov (United States)

    Kordass, B

    2006-04-01

    Individual masticatory patterns are similar to chaotic tangles of tortuous paths and are characterized by variability. The analysis of such masticatory patterns is therefore difficult. The new GEMAS software--Greifswald Movement Analyzing System--with which the variability of the masticatory function can be examined, is presented. Intersecting planes are placed through the orbit of the chewing cycles with which it is possible to wonder from the intercuspal position up to the maximum mouth-opening position of the masticatory pattern. The opening and closing points are displayed in different colors. Zones where masticatory paths converge or diverge can be determined, including the fan or funnel-shaped entering and exiting movements close to the centric position and the extent of their spread. A special diagram visualizes the rhythmic sequence of entering and subsequent exiting movement. The relation between restricted variability or monotony and forms of disease of the masticatory system is indicated by reference to case examples. The more monotonous or stereotyped the chewing cycles are, the higher is the risk of permanent wear of anatomical structures. Attention should therefore also be paid to variability in the individual occlusal surface design of dental restorations.

  9. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  10. The anatomical diaspora: evidence of early American anatomical traditions in North Dakota.

    Science.gov (United States)

    Stubblefield, Phoebe R

    2011-09-01

    The current focus in forensic anthropology on increasing scientific certainty in ancestry determination reinforces the need to examine the ancestry of skeletal remains used for osteology instruction. Human skeletal remains were discovered on the University of North Dakota campus in 2007. After recovery, the osteological examination resulted in a profile for a 33- to 46-year-old woman of African descent with stature ranging from 56.3 to 61.0 in. The pattern of postmortem damage indicated that the remains had been prepared for use as an anatomical teaching specimen. Review of the American history of anatomical teaching revealed a preference for Black subjects, which apparently extended to states like North Dakota despite extremely low resident populations of people of African descent. This study emphasizes the need to examine the ancestry of older teaching specimens that lack provenience, rather than assuming they are derived from typical (i.e., Indian) sources of anatomical material. © 2011 American Academy of Forensic Sciences.

  11. Anatomical Variation of the Maxillary Sinus in Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Marcelo Lupion Poleti

    2014-01-01

    Full Text Available Purpose. The aim of this paper is to report a case in which the cone beam computed tomography (CBCT was important for the confirmation of the presence of maxillary sinus septum and, therefore, the absence of a suspected pathologic process. Case Description. A 27-year-old male patient was referred for the assessment of a panoramic radiograph displaying a radiolucent area with radiopaque border located in the apical region of the left upper premolars. The provisional diagnosis was either anatomical variation of the maxillary sinuses or a bony lesion. Conclusion. The CBCT was important for an accurate assessment and further confirmation of the presence of maxillary septum, avoiding unnecessary surgical explorations.

  12. Evaluation of an integrated graphical display to promote acute change detection in ICU patients

    Science.gov (United States)

    Anders, Shilo; Albert, Robert; Miller, Anne; Weinger, Matthew B.; Doig, Alexa K.; Behrens, Michael; Agutter, Jim

    2012-01-01

    Objective The purpose of this study was to evaluate ICU nurses’ ability to detect patient change using an integrated graphical information display (IGID) versus a conventional tabular ICU patient information display (i.e. electronic chart). Design Using participants from two different sites, we conducted a repeated measures simulator-based experiment to assess ICU nurses’ ability to detect abnormal patient variables using a novel IGID versus a conventional tabular information display. Patient scenarios and display presentations were fully counterbalanced. Measurements We measured percent correct detection of abnormal patient variables, nurses’ perceived workload (NASA-TLX), and display usability ratings. Results 32 ICU nurses (87% female, median age of 29 years, and median ICU experience of 2.5 years) using the IGID detected more abnormal variables compared to the tabular display [F (1,119)=13.0, p < 0.05]. There was a significant main effect of site [F (1, 119)=14.2], with development site participants doing better. There were no significant differences in nurses’ perceived workload. The IGID display was rated as more usable than the conventional display, [F (1, 60)=31.7]. Conclusion Overall, nurses reported more important physiological information with the novel IGID than tabular display. Moreover, the finding of site differences may reflect local influences in work practice and involvement in iterative display design methodology. Information displays developed using user-centered design should accommodate the full diversity of the intended user population across use sites. PMID:22534099

  13. Major depressive disorder with melancholia displays robust alterations in resting state heart rate and its variability: Implications for future morbidity and mortality

    Directory of Open Access Journals (Sweden)

    Andrew eKemp

    2014-11-01

    Full Text Available Background: Major depressive disorder (MDD is associated with increased heart rate and reductions in its variability (HRV – markers of future morbidity and mortality – yet prior studies have reported contradictory effects. We hypothesised that increases in heart rate and reductions in HRV would be more robust in melancholia relative to controls, than in patients with non-melancholia. Methods: A total of 72 patients with a primary diagnosis of MDD (age M: 36.26, SE: 1.34; 42 females and 94 controls (age M: 35.69, SE: 1.16; 52 females were included in this study. Heart rate and measures of its variability (HRV were calculated from two 2-minute electrocardiogram recordings during resting state. Propensity score matching controlled imbalance on potential confounds between patients with melancholia (n=40 and non-melancholia (n=32 including age, gender, disorder severity and comorbid anxiety disorders. Results: MDD patients with melancholia displayed significantly increased heart rate and lower resting-state HRV (including the square root of the mean squared differences between successive N–N intervals, the absolute power of high frequency and standard deviation of the Poincaré plot perpendicular to the line of identity measures of HRV relative to controls, findings associated with a moderate effect size (Cohens d’s = 0.56-0.58. Patients with melancholia also displayed an increased heart rate relative to those with non-melancholia (Cohen’s d = 0.20.Conclusion: MDD patients with melancholia – but not non-melancholia – display robust increases in heart rate and decreases in HRV. These findings may underpin a variety of behavioural impairments in patients with melancholia including somatic symptoms, cognitive impairment, reduced responsiveness to the environment, and over the longer-term, morbidity and mortality.

  14. Prostatome: A combined anatomical and disease based MRI atlas of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela; Madabhushi, Anant, E-mail: anant.madabhushi@case.edu [Case Western Reserve University, Cleveland, Ohio 44106 (United States); Bloch, B. Nicolas; Jaffe, Carl C. [Boston University School of Medicine, Boston, Massachusetts 02118 (United States); Genega, Elizabeth M. [Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215 (United States); Lenkinski, Robert E.; Rofsky, Neil M. [UT Southwestern Medical Center, Dallas, Texas 75235 (United States); Feleppa, Ernest [Riverside Research Institute, New York, New York 10038 (United States)

    2014-07-15

    Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework

  15. Prostatome: A combined anatomical and disease based MRI atlas of the prostate

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Madabhushi, Anant; Bloch, B. Nicolas; Jaffe, Carl C.; Genega, Elizabeth M.; Lenkinski, Robert E.; Rofsky, Neil M.; Feleppa, Ernest

    2014-01-01

    Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework

  16. Safety parameter display systems' effect on operator performance

    International Nuclear Information System (INIS)

    Cerven, F.; Ford, R.E.; Blackman, H.S.

    1983-01-01

    Computer generated displays are a powerful and flexible tool for presenting data to the operators of nuclear power plants. Such displays are currently being developed in industry for use as safety parameter displays and for use in advanced control rooms. There exists a need for methods to objectively evaluate the effect of these displays, positive or negative, on the performance of control room personnel. Results of developing one such method, noninteractive simulation, and the two experiments that were performed to determine if it can be used as a method for evaluating computer displays are presented. This method is more objective and powerful than pencil and paper methods because it measures human performance rather than opinion or perference, has excellent control of the experimental variables, and has a higher fidelity to the control room environment. The results of these experiments indicates that the present methodology does not differentiate among the display types tested at a statistically significant level. In other words, all display types tested worked equally well in providing operators needed information

  17. Anatomical variability of the trunk wood and root tissues of ...

    African Journals Online (AJOL)

    Any interspecies variability was found between their trunk vessels diameter. However, a significant ... are discharged in the sea, releasing like this toxic organic ...... Water. Discharge on nutrient contamination of mangrove soils and plants.

  18. The variability of leaf anatomical characteristics of Solanum nigrum L. (Solana-les, Solanaceae) from different habitats

    OpenAIRE

    Krstić Lana N.; Merkulov Ljiljana S.; Boža Pal P.

    2002-01-01

    In Europe on the whole as well as in Yugoslavia, the most widespread weed species from the genus Solanum is Solanum nigrum L. Since this species inhabits different habitats, it developed several ways of adaptation to environmental conditions. The influence of ecological factors on plant organism and resulting plant adaptations are most evident in leaf morphology and anatomy. Therefore, the anatomical structure of leaves and leaf epidermal tissue of S. nigrum was analyzed and compared among pl...

  19. Patient reported and anatomical outcomes after surgery for pelvic organ prolapse.

    Science.gov (United States)

    El-Azab, Ahmed S; Abd-Elsayed, Alaa A; Imam, Hala M K

    2009-01-01

    Primary aim was to modify Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ) to assess pelvic organ prolapse (POP) in Arabic Muslim women. Secondary aim was to compare functional and anatomical outcomes of POP repair. Questionnaire. A characteristic (prayer) was added to PFIQ. Linguistic validation of questionnaires was then done. Twenty cases were enrolled in a pilot study to test internal consistency and reliability. Subsequent study. Prospective study included women with symptomatic POP >or= stage II. History, examination by POP-Q, and administration of PFDI and PFIQ, were done before and 6 months after surgery. Questionnaire. Internal consistency of added question was good (Cronbach alpha = 0.78). Test-retest reliability of individual PFIQ items was variable. Subsequent Study. Between September 2004 and February 2007, 78 consecutive women were included. Cystocele, rectocele, and no site predominated in 74.4%, 17.9% and 7.7% of cases, respectively. Preoperatively 19.2%, 15.4% and 47.4% reported stress, urge, and mixed incontinence, respectively. Overall and individual urinary symptoms scores improved significantly after surgery. There were significant improvements in individual symptoms of constipation, splint to defecate and losing not well formed stools. Low self-esteem was most negative impact of prolapse on quality of life (QoL) followed by prayer. After surgery 90% of subjects had anatomical cure. After surgery, QoL issues are significantly related to anatomic location of prolapse as determined by POP-Q. Modified PFIQ and PFDI are suitable to assess POP among Muslim women. Postoperatively, many prolapse-related symptoms and QoL significantly improve after surgery on the short term with an anatomic cure rate of 90%.

  20. Registration and display of brain SPECT and MRI using external markers

    International Nuclear Information System (INIS)

    Pohjonen, H.; Nikkinen, P.; Sipilae, O.; Launes, J.; Salli, E.; Salonen, O.; Karp, P.; Ylae-Jaeaeski, J.; Katila, T.; Liewendahl, K.

    1996-01-01

    Accurate anatomical localisation of abnormalities observed in brain perfusion single-photon emission computed tomography (SPECT) is difficult, but can be improved by correlating data from SPECT and other tomographic imaging modalities. For this purpose we have developed software to register, analyse and display 99m Tc-hexamethylpropyleneamine oxime SPECT and 1.0 T MRI of the brain. For registration of SPECT and MRI data external skin markers containing 99m Tc (220 kBq) in 50 μl of coconut butter were used. The software is coded in the C programming language, and the X Window system and the OSF/Motif standards are used for graphics and definition of the user interface. The registration algorithm follows a noniterative least-squares method using singular value decomposition of a 3 x 3 covariance matrix. After registration, the image slices of both data sets are shown at identical tomographic levels. The registration error in phantom studies was on average 4 mm. In the two-dimensional display mode the orthogonal cross-sections of the data sets are displayed side by side. In the three-dimensional mode MRI data are displayed as a surface-shaded 3 D reconstruction and SPECT data as cut planes. The usefulness of this method is demonstrated in patients with cerebral infarcts, brain tumour, herpes simplex encephalitis and epilepsy. (orig.). With 9 figs

  1. Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Fagertun, Jens; Vera, Sergio

    2016-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Proper non-rigid alignment of high-resolution cochlear μCT data is a challenge for the typical cubic B-spline registration model. In this paper we study one way ...

  2. The method to make the three dimensional anatomical pattern of hepatic vessels by stereo angiography

    International Nuclear Information System (INIS)

    Mutou, Haruomi; Kobayashi, Seiichiro; Yamada, Akiyoshi; Takasaki, Takeshi; Isobe, Yoshinori; Tanaka, Seiichi; Saeki, Shin; Yoshida, Masanori

    1986-01-01

    For the Past few years, there has been a big advance in the hepatic surgery. Now, small resection, such as segmentectomy or subsegmentectomy, is performed routinely. Based on this tendency, hepatic surgeons request more details, more stereographic findings of hepatic vessels to heaptic angiography. Especially three dimensional combined anatomical pattern of the hepatic artery, portal vein and hepatic vein is strongly needed. We have tried three dimensional computer graphic of hepatic vessels since few years ago, using the personal computer, digitizer with clear screen, commercially available 3D software and my own program. We use three groups of angiographic films, that is the hepatic artery, portal vein and hepatic vein with IVC, which were taken by stereoangiography. The depth of each poits of vessels are calculated by the way described in Fig 3. Using these points, the 3D software, '3DPROGATS', can make the anatomical pattern of combined hepatic vessels on TV display. And then we can also perform rotation, heading, bank, zooming, hidden line elimination freely for this picture. Out of necessity as hepatic surgeons, we make a simple system for 3D computer graphic of heptic vessels. At present, the image is somewhat rough, but clinically it is relatively effective. In this report we want to explain our method and to show the anatomical pattern of hepatic vessels of case of hepatoma. (author)

  3. Introducing 3-Dimensional Printing of a Human Anatomic Pathology Specimen: Potential Benefits for Undergraduate and Postgraduate Education and Anatomic Pathology Practice.

    Science.gov (United States)

    Mahmoud, Amr; Bennett, Michael

    2015-08-01

    Three-dimensional (3D) printing, a rapidly advancing technology, is widely applied in fields such as mechanical engineering and architecture. Three-dimensional printing has been introduced recently into medical practice in areas such as reconstructive surgery, as well as in clinical research. Three-dimensionally printed models of anatomic and autopsy pathology specimens can be used for demonstrating pathology entities to undergraduate medical, dental, and biomedical students, as well as for postgraduate training in examination of gross specimens for anatomic pathology residents and pathology assistants, aiding clinicopathological correlation at multidisciplinary team meetings, and guiding reconstructive surgical procedures. To apply 3D printing in anatomic pathology for teaching, training, and clinical correlation purposes. Multicolored 3D printing of human anatomic pathology specimens was achieved using a ZCorp 510 3D printer (3D Systems, Rock Hill, South Carolina) following creation of a 3D model using Autodesk 123D Catch software (Autodesk, Inc, San Francisco, California). Three-dimensionally printed models of anatomic pathology specimens created included pancreatoduodenectomy (Whipple operation) and radical nephrectomy specimens. The models accurately depicted the topographic anatomy of selected specimens and illustrated the anatomic relation of excised lesions to adjacent normal tissues. Three-dimensional printing of human anatomic pathology specimens is achievable. Advances in 3D printing technology may further improve the quality of 3D printable anatomic pathology specimens.

  4. TIBIAL LANDMARKS IN ACL ANATOMIC REPAIR

    Directory of Open Access Journals (Sweden)

    M. V. Demesсhenko

    2016-01-01

    Full Text Available Purpose: to identify anatomical landmarks on tibial articular surface to serve as reference in preparing tibial canal with respect to the center of ACL footprint during single bundle arthroscopic repair.Materials and methods. Twelve frozen knee joint specimens and 68 unpaired macerated human tibia were studied using anatomical, morphometric, statistical methods as well as graphic simulation.Results. Center of the tibial ACL footprint was located 13,1±1,7 mm anteriorly from posterior border of intercondylar eminence, at 1/3 of the distance along the line connecting apexes of internal and external tubercles and 6,1±0,5 mm anteriorly along the perpendicular raised to this point.Conclusion. Internal and external tubercles, as well as posterior border of intercondylar eminence can be considered as anatomical references to determine the center of the tibial ACL footprint and to prepare bone canals for anatomic ligament repair.

  5. Consensus guidelines for the uniform reporting of study ethics in anatomical research within the framework of the anatomical quality assurance (AQUA) checklist.

    Science.gov (United States)

    Henry, Brandon Michael; Vikse, Jens; Pekala, Przemyslaw; Loukas, Marios; Tubbs, R Shane; Walocha, Jerzy A; Jones, D Gareth; Tomaszewski, Krzysztof A

    2018-05-01

    Unambiguous reporting of a study's compliance with ethical guidelines in anatomical research is imperative. As such, clear, universal, and uniform reporting guidelines for study ethics are essential. In 2016, the International Evidence-Based Anatomy Working group in collaboration with international partners established reporting guidelines for anatomical studies, the Anatomical Quality Assurance (AQUA) Checklist. In this elaboration of the AQUA Checklist, consensus guidelines for reporting study ethics in anatomical studies are provided with in the framework of the AQUA Checklist. The new guidelines are aimed to be applicable to research across the spectrum of the anatomical sciences, including studies on both living and deceased donors. The authors hope the established guidelines will improve ethical compliance and reporting in anatomical research. Clin. Anat. 31:521-524, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  6. Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    Science.gov (United States)

    Boser, Quinn A; Valevicius, Aïda M; Lavoie, Ewen B; Chapman, Craig S; Pilarski, Patrick M; Hebert, Jacqueline S; Vette, Albert H

    2018-04-27

    Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and intra- and inter-tester variability. An alternative method involves the tracking of rigid marker clusters affixed to body segments, calibrated relative to anatomical landmarks or known joint angles. The accuracy and reliability of applying this cluster method to the upper body has, however, not been comprehensively explored. Our objective was to compare three different upper body cluster models with an anatomical model, with respect to joint angles and reliability. Non-disabled participants performed two standardized functional upper limb tasks with anatomical and cluster markers applied concurrently. Joint angle curves obtained via the marker clusters with three different calibration methods were compared to those from an anatomical model, and between-session reliability was assessed for all models. The cluster models produced joint angle curves which were comparable to and highly correlated with those from the anatomical model, but exhibited notable offsets and differences in sensitivity for some degrees of freedom. Between-session reliability was comparable between all models, and good for most degrees of freedom. Overall, the cluster models produced reliable joint angles that, however, cannot be used interchangeably with anatomical model outputs to calculate kinematic metrics. Cluster models appear to be an adequate, and possibly advantageous alternative to anatomical models when the objective is to assess trends in movement behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Advanced Transport Operating System (ATOPS) color displays software description microprocessor system

    Science.gov (United States)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Sperry Microprocessor Color Display System used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global reference section includes procedures and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight cathode ray tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  8. Intraspecific Variation in Wood Anatomical, Hydraulic, and Foliar Traits in Ten European Beech Provenances Differing in Growth Yield

    Science.gov (United States)

    Hajek, Peter; Kurjak, Daniel; von Wühlisch, Georg; Delzon, Sylvain; Schuldt, Bernhard

    2016-01-01

    In angiosperms, many studies have described the inter-specific variability of hydraulic-related traits and little is known at the intra-specific level. This information is however mandatory to assess the adaptive capacities of tree populations in the context of increasing drought frequency and severity. Ten 20-year old European beech (Fagus sylvatica L.) provenances representing the entire distribution range throughout Europe and differing significantly in aboveground biomass increment (ABI) by a factor of up to four were investigated for branch wood anatomical, hydraulic, and foliar traits in a provenance trial located in Northern Europe. We quantified to which extend xylem hydraulic and leaf traits are under genetic control and tested whether the xylem hydraulic properties (hydraulic efficiency and safety) trades off with yield and wood anatomical and leaf traits. Our results showed that only three out of 22 investigated ecophysiological traits showed significant genetic differentiations between provenances, namely vessel density (VD), the xylem pressure causing 88% loss of hydraulic conductance and mean leaf size. Depending of the ecophysiological traits measured, genetic differentiation between populations explained 0–14% of total phenotypic variation, while intra-population variability was higher than inter-population variability. Most wood anatomical traits and some foliar traits were additionally related to the climate of provenance origin. The lumen to sapwood area ratio, vessel diameter, theoretical specific conductivity and theoretical leaf-specific conductivity as well as the C:N-ratio increased with climatic aridity at the place of origin while the carbon isotope signature (δ13C) decreased. Contrary to our assumption, none of the wood anatomical traits were related to embolism resistance but were strong determinants of hydraulic efficiency. Although ABI was associated with both VD and δ13C, both hydraulic efficiency and embolism resistance were

  9. A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability in pediatric feet.

    Science.gov (United States)

    Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B

    2012-04-01

    Several multi-segment foot models to measure the motion of intrinsic joints of the foot have been reported. Use of these models in clinical decision making is limited due to lack of rigorous validation including inter-clinician, and inter-lab variability measures. A model with thoroughly quantified variability may significantly improve the confidence in the results of such foot models. This study proposes a new clinical foot model with the underlying strategy of using separate anatomic and technical marker configurations and coordinate systems. Anatomical landmark and coordinate system identification is determined during a static subject calibration. Technical markers are located at optimal sites for dynamic motion tracking. The model is comprised of the tibia and three foot segments (hindfoot, forefoot and hallux) and inter-segmental joint angles are computed in three planes. Data collection was carried out on pediatric subjects at two sites (Site 1: n=10 subjects by two clinicians and Site 2: five subjects by one clinician). A plaster mold method was used to quantify static intra-clinician and inter-clinician marker placement variability by allowing direct comparisons of marker data between sessions for each subject. Intra-clinician and inter-clinician joint angle variability were less than 4°. For dynamic walking kinematics, intra-clinician, inter-clinician and inter-laboratory variability were less than 6° for the ankle and forefoot, but slightly higher for the hallux. Inter-trial variability accounted for 2-4° of the total dynamic variability. Results indicate the proposed foot model reduces the effects of marker placement variability on computed foot kinematics during walking compared to similar measures in previous models. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Dynamic article: surgical anatomical planes for complete mesocolic excision and applied vascular anatomy of the right colon.

    Science.gov (United States)

    Açar, Halil İbrahim; Cömert, Ayhan; Avşar, Abdullah; Çelik, Safa; Kuzu, Mehmet Ayhan

    2014-10-01

    Lower local recurrence rates and better overall survival are associated with complete mesocolic excision with central vascular ligation for treatment of colon cancer. To accomplish this, surgeons need to pay special attention to the surgical anatomical planes and vascular anatomy of the colon. However, surgical education in this area has been neglected. The aim of this study is to define the correct surgical anatomical planes for complete mesocolic excision with central vascular ligation and to demonstrate the correct dissection technique for protecting anatomical structures. Macroscopic and microscopic surgical dissections were performed on 12 cadavers in the anatomy laboratory and on autopsy specimens. The dissections were recorded as video clips. Dissections were performed in accordance with the complete mesocolic excision technique on 10 male and 2 female cadavers. Vascular structures, autonomic nerves, and related fascias were shown. Within each step of the surgical procedure, important anatomical structures were displayed on still images captured from videos by animations. Three crucial steps for complete mesocolic excision with central vascular ligation are demonstrated on the cadavers: 1) full mobilization of the superior mesenteric root following the embryological planes between the visceral and the parietal fascias; 2) mobilization of the mesocolon from the duodenum and the pancreas and identification of vascular structures, especially the veins around the pancreas; and 3) central vascular ligation of the colonic vessels at their origin, taking into account the vascular variations within the mesocolonic vessels and the autonomic nerves around the superior mesenteric artery. The limitation of this study was the number of the cadavers used. Successful complete mesocolic excision with central vascular ligation depends on an accurate knowledge of the surgical anatomical planes and the vascular anatomy of the colon.

  11. A simple signaling rule for variable life-adjusted display derived from an equivalent risk-adjusted CUSUM chart.

    Science.gov (United States)

    Wittenberg, Philipp; Gan, Fah Fatt; Knoth, Sven

    2018-04-17

    The variable life-adjusted display (VLAD) is the first risk-adjusted graphical procedure proposed in the literature for monitoring the performance of a surgeon. It displays the cumulative sum of expected minus observed deaths. It has since become highly popular because the statistic plotted is easy to understand. But it is also easy to misinterpret a surgeon's performance by utilizing the VLAD, potentially leading to grave consequences. The problem of misinterpretation is essentially caused by the variance of the VLAD's statistic that increases with sample size. In order for the VLAD to be truly useful, a simple signaling rule is desperately needed. Various forms of signaling rules have been developed, but they are usually quite complicated. Without signaling rules, making inferences using the VLAD alone is difficult if not misleading. In this paper, we establish an equivalence between a VLAD with V-mask and a risk-adjusted cumulative sum (RA-CUSUM) chart based on the difference between the estimated probability of death and surgical outcome. Average run length analysis based on simulation shows that this particular RA-CUSUM chart has similar performance as compared to the established RA-CUSUM chart based on the log-likelihood ratio statistic obtained by testing the odds ratio of death. We provide a simple design procedure for determining the V-mask parameters based on a resampling approach. Resampling from a real data set ensures that these parameters can be estimated appropriately. Finally, we illustrate the monitoring of a real surgeon's performance using VLAD with V-mask. Copyright © 2018 John Wiley & Sons, Ltd.

  12. DPAK and HPAK: a versatile display and histogramming package

    International Nuclear Information System (INIS)

    Logg, C.A.; Boyarski, A.M.; Cook, A.J.; Cottrell, R.L.A.; Sund, S.

    1979-07-01

    The features of a display and histogram package which requires a minimal number of subroutine calls in order to generate graphic output in many flavors on a variety of devices are described. Default options are preset to values that are generally most wanted, but the default values may be readily changed to the user's needs. The description falls naturally into two parts, namely, the set of routines (DPAK) for displaying data on some device, and the set of routines (HPAK) for generating histograms. HPAK provides a means of allocating memory for histograms, accumulating data into histograms, and subsequently displaying the hisotgrams via calls to the DPAK routines. Histograms and displays of either one or two independent variables can be made

  13. Quantifying agreement between anatomical and functional interhemispheric correspondences in the resting brain.

    Directory of Open Access Journals (Sweden)

    Hang Joon Jo

    Full Text Available The human brain is composed of two broadly symmetric cerebral hemispheres, with an abundance of reciprocal anatomical connections between homotopic locations. However, to date, studies of hemispheric symmetries have not identified correspondency precisely due to variable cortical folding patterns. Here we present a method to establish accurate correspondency using position on the unfolded cortical surface relative to gyral and sulcal landmarks. The landmark method is shown to outperform the method of reversing standard volume coordinates, and it is used to quantify the functional symmetry in resting fMRI data throughout the cortex. Resting brain activity was found to be maximally correlated with locations less than 1 cm away on the cortical surface from the corresponding anatomical location in nearly half of the cortex. While select locations exhibited asymmetric patterns, precise symmetric relationships were found to be the norm, with fine-grained symmetric functional maps demonstrated in motor, occipital, and inferior frontal cortex.

  14. Production of a phage-displayed single chain variable fragment ...

    African Journals Online (AJOL)

    Abstract. Purpose: To develop specific single chain variable fragments (scFv) against ... libraries. The binding ability of the selected scFv antibody fragments against the IBDV particles was ..... Hermelink H, Koscielniak E. A human recombinant.

  15. Anatomical eponyms - unloved names in medical terminology.

    Science.gov (United States)

    Burdan, F; Dworzański, W; Cendrowska-Pinkosz, M; Burdan, M; Dworzańska, A

    2016-01-01

    Uniform international terminology is a fundamental issue of medicine. Names of various organs or structures have developed since early human history. The first proper anatomical books were written by Hippocrates, Aristotle and Galen. For this reason the modern terms originated from Latin or Greek. In a modern time the terminology was improved in particular by Vasalius, Fabricius and Harvey. Presently each known structure has internationally approved term that is explained in anatomical or histological terminology. However, some elements received eponyms, terms that incorporate the surname of the people that usually describe them for the first time or studied them (e.g., circle of Willis, follicle of Graff, fossa of Sylvious, foramen of Monro, Adamkiewicz artery). Literature and historical hero also influenced medical vocabulary (e.g. Achilles tendon and Atlas). According to various scientists, all the eponyms bring colour to medicine, embed medical traditions and culture to our history but lack accuracy, lead of confusion, and hamper scientific discussion. The current article presents a wide list of the anatomical eponyms with their proper anatomical term or description according to international anatomical terminology. However, since different eponyms are used in various countries, the list could be expanded.

  16. Anatomical Variations in the Sinoatrial Nodal Artery: A Meta-Analysis and Clinical Considerations.

    Directory of Open Access Journals (Sweden)

    Jens Vikse

    Full Text Available The sinoatrial nodal artery (SANa is a highly variable vessel which supplies blood to the sinoatrial node (SAN. Due to its variability and susceptibility to iatrogenic injury, our study aimed to assess the anatomy of the SANa and determine the prevalence of its anatomical variations.An extensive search of major electronic databases was performed to identify all articles reporting anatomical data on the SANa. No lower date limit or language restrictions were applied. Anatomical data regarding the artery were extracted and pooled into a meta-analysis.Sixty-six studies (n = 21455 hearts were included in the meta-analysis. The SANa usually arose as a single vessel with a pooled prevalence of 95.5% (95%CI:93.6-96.9. Duplication and triplication of the artery were also observed with pooled prevalence of 4.3% (95%CI:2.8-6.0 and 0.3% (95%CI:0-0.7, respectively. The most common origin of the SANa was from the right coronary artery (RCA, found in 68.0% (95%CI:55.6-68.9 of cases, followed by origin from the left circumflex artery, and origin from the left coronary artery with pooled prevalence of 22.1% (95%CI:15.0-26.2 and 2.7 (95%CI:0.7-5.2, respectively. A retrocaval course of the SANa was the most common course of the artery with a pooled prevalence of 47.1% (95%CI:36.0-55.5. The pooled prevalence of an S-shaped SANa was 7.6% (95%CI:2.9-14.1.The SANa is most commonly reported as a single vessel, originating from the RCA, and taking a retrocaval course to reach the SAN. Knowledge of high risk anatomical variants of the SANa, such as an S-shaped artery, must be taken into account by surgeons to prevent iatrogenic injuries. Specifically, interventional or cardiosurgical procedures, such as the Cox maze procedure for atrial fibrillation, open heart surgeries through the right atrium or intraoperative cross-clamping or dissection procedures during mitral valve surgery using the septal approach can all potentiate the risk for injury in the setting of high

  17. Real-time 3-dimensional fetal echocardiography with an instantaneous volume-rendered display: early description and pictorial essay.

    Science.gov (United States)

    Sklansky, Mark S; DeVore, Greggory R; Wong, Pierre C

    2004-02-01

    Random fetal motion, rapid fetal heart rates, and cumbersome processing algorithms have limited reconstructive approaches to 3-dimensional fetal cardiac imaging. Given the recent development of real-time, instantaneous volume-rendered sonographic displays of volume data, we sought to apply this technology to fetal cardiac imaging. We obtained 1 to 6 volume data sets on each of 30 fetal hearts referred for formal fetal echocardiography. Each volume data set was acquired over 2 to 8 seconds and stored on the system's hard drive. Rendered images were subsequently processed to optimize translucency, smoothing, and orientation and cropped to reveal "surgeon's eye views" of clinically relevant anatomic structures. Qualitative comparison was made with conventional fetal echocardiography for each subject. Volume-rendered displays identified all major abnormalities but failed to identify small ventricular septal defects in 2 patients. Important planes and views not visualized during the actual scans were generated with minimal processing of rendered image displays. Volume-rendered displays tended to have slightly inferior image quality compared with conventional 2-dimensional images. Real-time 3-dimensional echocardiography with instantaneous volume-rendered displays of the fetal heart represents a new approach to fetal cardiac imaging with tremendous clinical potential.

  18. Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system

    Science.gov (United States)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  19. Anatomical background and generalized detectability in tomosynthesis and cone-beam CT

    International Nuclear Information System (INIS)

    Gang, G. J.; Tward, D. J.; Lee, J.; Siewerdsen, J. H.

    2010-01-01

    Purpose: Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background ''noise'' in cascaded systems analysis of 2D and 3D imaging performance to yield ''generalized'' metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. Methods: A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density (κ/f β ) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S B (f)] were computed as a function of source-detector orbital extent, including tomosynthesis (∼10 deg. - 180 deg.) and CBCT (180 deg. +fan to 360 deg.) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S B was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. Results: The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude (κ) and correlation (β) with increasing tomosynthesis angle. Incorporation of S B in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design--applications varying significantly in κ and β, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e

  20. Determining customer satisfaction in anatomic pathology.

    Science.gov (United States)

    Zarbo, Richard J

    2006-05-01

    Measurement of physicians' and patients' satisfaction with laboratory services has become a standard practice in the United States, prompted by national accreditation requirements. Unlike other surveys of hospital-, outpatient care-, or physician-related activities, no ongoing, comprehensive customer satisfaction survey of anatomic pathology services is available for subscription that would allow continual benchmarking against peer laboratories. Pathologists, therefore, must often design their own local assessment tools to determine physician satisfaction in anatomic pathology. To describe satisfaction survey design that would elicit specific information from physician customers about key elements of anatomic pathology services. The author shares his experience in biannually assessing customer satisfaction in anatomic pathology with survey tools designed at the Henry Ford Hospital, Detroit, Mich. Benchmarks for physician satisfaction, opportunities for improvement, and characteristics that correlated with a high level of physician satisfaction were identified nationally from a standardized survey tool used by 94 laboratories in the 2001 College of American Pathologists Q-Probes quality improvement program. In general, physicians are most satisfied with professional diagnostic services and least satisfied with pathology services related to poor communication. A well-designed and conducted customer satisfaction survey is an opportunity for pathologists to periodically educate physician customers about services offered, manage unrealistic expectations, and understand the evolving needs of the physician customer. Armed with current information from physician customers, the pathologist is better able to strategically plan for resources that facilitate performance improvements in anatomic pathology laboratory services that align with evolving clinical needs in health care delivery.

  1. TissueCypher™: A systems biology approach to anatomic pathology

    Directory of Open Access Journals (Sweden)

    Jeffrey W Prichard

    2015-01-01

    Full Text Available Background: Current histologic methods for diagnosis are limited by intra- and inter-observer variability. Immunohistochemistry (IHC methods are frequently used to assess biomarkers to aid diagnoses, however, IHC staining is variable and nonlinear and the manual interpretation is subjective. Furthermore, the biomarkers assessed clinically are typically biomarkers of epithelial cell processes. Tumors and premalignant tissues are not composed only of epithelial cells but are interacting systems of multiple cell types, including various stromal cell types that are involved in cancer development. The complex network of the tissue system highlights the need for a systems biology approach to anatomic pathology, in which quantification of system processes is combined with informatics tools to produce actionable scores to aid clinical decision-making. Aims: Here, we describe a quantitative, multiplexed biomarker imaging approach termed TissueCypher™ that applies systems biology to anatomic pathology. Applications of TissueCypher™ in understanding the tissue system of Barrett's esophagus (BE and the potential use as an adjunctive tool in the diagnosis of BE are described. Patients and Methods: The TissueCypher™ Image Analysis Platform was used to assess 14 epithelial and stromal biomarkers with known diagnostic significance in BE in a set of BE biopsies with nondysplastic BE with reactive atypia (RA, n = 22 and Barrett's with high-grade dysplasia (HGD, n = 17. Biomarker and morphology features were extracted and evaluated in the confirmed BE HGD cases versus the nondysplastic BE cases with RA. Results: Multiple image analysis features derived from epithelial and stromal biomarkers, including immune biomarkers and morphology, showed significant differences between HGD and RA. Conclusions: The assessment of epithelial cell abnormalities combined with an assessment of cellular changes in the lamina propria may serve as an adjunct to conventional

  2. Anatomical Basis for the Cardiac Interventional Electrophysiologist

    Directory of Open Access Journals (Sweden)

    Damián Sánchez-Quintana

    2015-01-01

    Full Text Available The establishment of radiofrequency catheter ablation techniques as the mainstay in the treatment of tachycardia has renewed new interest in cardiac anatomy. The interventional arrhythmologist has drawn attention not only to the gross anatomic details of the heart but also to architectural and histological characteristics of various cardiac regions that are relevant to the development or recurrence of tachyarrhythmias and procedural related complications of catheter ablation. In this review, therefore, we discuss some anatomic landmarks commonly used in catheter ablations including the terminal crest, sinus node region, Koch’s triangle, cavotricuspid isthmus, Eustachian ridge and valve, pulmonary venous orifices, venoatrial junctions, and ventricular outflow tracts. We also discuss the anatomical features of important structures in the vicinity of the atria and pulmonary veins, such as the esophagus and phrenic nerves. This paper provides basic anatomic information to improve understanding of the mapping and ablative procedures for cardiac interventional electrophysiologists.

  3. 3D display system using monocular multiview displays

    Science.gov (United States)

    Sakamoto, Kunio; Saruta, Kazuki; Takeda, Kazutoki

    2002-05-01

    A 3D head mounted display (HMD) system is useful for constructing a virtual space. The authors have researched the virtual-reality systems connected with computer networks for real-time remote control and developed a low-priced real-time 3D display for building these systems. We developed a 3D HMD system using monocular multi-view displays. The 3D displaying technique of this monocular multi-view display is based on the concept of the super multi-view proposed by Kajiki at TAO (Telecommunications Advancement Organization of Japan) in 1996. Our 3D HMD has two monocular multi-view displays (used as a visual display unit) in order to display a picture to the left eye and the right eye. The left and right images are a pair of stereoscopic images for the left and right eyes, then stereoscopic 3D images are observed.

  4. Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Wang, Yiping; Wang, Huixiang; Wang, Fang; Zeng, Xiangsen; Wang, Qiugen; Egger, Jan

    2015-06-01

    The surgical navigation system has experienced tremendous development over the past decades for minimizing the risks and improving the precision of the surgery. Nowadays, Augmented Reality (AR)-based surgical navigation is a promising technology for clinical applications. In the AR system, virtual and actual reality are mixed, offering real-time, high-quality visualization of an extensive variety of information to the users (Moussa et al., 2012) [1]. For example, virtual anatomical structures such as soft tissues, blood vessels and nerves can be integrated with the real-world scenario in real time. In this study, an AR-based surgical navigation system (AR-SNS) is developed using an optical see-through HMD (head-mounted display), aiming at improving the safety and reliability of the surgery. With the use of this system, including the calibration of instruments, registration, and the calibration of HMD, the 3D virtual critical anatomical structures in the head-mounted display are aligned with the actual structures of patient in real-world scenario during the intra-operative motion tracking process. The accuracy verification experiment demonstrated that the mean distance and angular errors were respectively 0.809±0.05mm and 1.038°±0.05°, which was sufficient to meet the clinical requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  6. Interpreting and Integrating Clinical and Anatomic Pathology Results.

    Science.gov (United States)

    Ramaiah, Lila; Hinrichs, Mary Jane; Skuba, Elizabeth V; Iverson, William O; Ennulat, Daniela

    2017-01-01

    The continuing education course on integrating clinical and anatomical pathology data was designed to communicate the importance of using a weight of evidence approach to interpret safety findings in toxicology studies. This approach is necessary, as neither clinical nor anatomic pathology data can be relied upon in isolation to fully understand the relationship between study findings and the test article. Basic principles for correlating anatomic pathology and clinical pathology findings and for integrating these with other study end points were reviewed. To highlight these relationships, a series of case examples, presented jointly by a clinical pathologist and an anatomic pathologist, were used to illustrate the collaborative effort required between clinical and anatomical pathologists. In addition, the diagnostic utility of traditional liver biomarkers was discussed using results from a meta-analysis of rat hepatobiliary marker and histopathology data. This discussion also included examples of traditional and novel liver and renal biomarker data implementation in nonclinical toxicology studies to illustrate the relationship between discrete changes in biochemistry and tissue morphology.

  7. A storage and display method for radioisotope imaging using scan conversion memory

    International Nuclear Information System (INIS)

    Takizawa, Masaomi; Kobayashi, Toshio; Nakanishi, Fumiko; Suzuki, Shigeo; Miyabayashi, Hiroyasu

    1975-01-01

    The scan conversion memory (SCM) has been applied to a method for the storage and display of radioisotope images. Scan data were fed into SCM as pulse signals with X and Y axis from the scinti-scanner or the scinti-camera. The electric charge on the SCM target is directly proportional to the pulse density. A TV display was executed immediately after the recording of a radioisotope image. If necessary, a seven additive color display to the image density could be obtained by a simple color slicer, and the image could be hard-copied by a video hard-copy printer. Characteristics of the SCM were experimentally clarified as follows: the practical resolution was 700 line/TV; ten levels gray scale were discriminated on the video monitor, the uniformity, measured by an oscilloscope was less than 20%, and dead time of the pulse interval at full scale signal was 5 μ sec. In their representation, the SCM scintigrams were observed as closely resembling conventional film scintigrams. Superimposed imaging of an X-ray picture and a radioisotope image can be realized by using the SCM, for an increase in anatomical localization on reading images. The SCM scintigram can be applied rapidly and can be the viewer of radioisotope imaging. (auth.)

  8. Anatomical and palynological characteristics of Salvia willeana ...

    African Journals Online (AJOL)

    In this study, anatomical and palynological features of the roots, stems, petiole and leaves of Salvia willeana (Holmboe) Hedge and Salvia veneris Hedge, Salvia species endemic to Cyprus, were investigated. In the anatomical characteristics of stem structures, it was found that the chlorenchyma composed of 6 or 7 rows of ...

  9. Standards to support information systems integration in anatomic pathology.

    Science.gov (United States)

    Daniel, Christel; García Rojo, Marcial; Bourquard, Karima; Henin, Dominique; Schrader, Thomas; Della Mea, Vincenzo; Gilbertson, John; Beckwith, Bruce A

    2009-11-01

    Integrating anatomic pathology information- text and images-into electronic health care records is a key challenge for enhancing clinical information exchange between anatomic pathologists and clinicians. The aim of the Integrating the Healthcare Enterprise (IHE) international initiative is precisely to ensure interoperability of clinical information systems by using existing widespread industry standards such as Digital Imaging and Communication in Medicine (DICOM) and Health Level Seven (HL7). To define standard-based informatics transactions to integrate anatomic pathology information to the Healthcare Enterprise. We used the methodology of the IHE initiative. Working groups from IHE, HL7, and DICOM, with special interest in anatomic pathology, defined consensual technical solutions to provide end-users with improved access to consistent information across multiple information systems. The IHE anatomic pathology technical framework describes a first integration profile, "Anatomic Pathology Workflow," dedicated to the diagnostic process including basic image acquisition and reporting solutions. This integration profile relies on 10 transactions based on HL7 or DICOM standards. A common specimen model was defined to consistently identify and describe specimens in both HL7 and DICOM transactions. The IHE anatomic pathology working group has defined standard-based informatics transactions to support the basic diagnostic workflow in anatomic pathology laboratories. In further stages, the technical framework will be completed to manage whole-slide images and semantically rich structured reports in the diagnostic workflow and to integrate systems used for patient care and those used for research activities (such as tissue bank databases or tissue microarrayers).

  10. Double uterus with obstructed hemivagina and ipsilateral renal agenesis: pelvic anatomic variants in 87 cases.

    Science.gov (United States)

    Fedele, L; Motta, F; Frontino, G; Restelli, E; Bianchi, S

    2013-06-01

    What are the anatomic variants (and their frequencies) of double uterus, obstructed hemivagina and ipsilateral renal agenesis? Most cases examined (72.4%) were of the classic anatomic variant of the Herlyn-Werner-Wunderlich syndrome (with didelphys uterus, obstructed hemivagina and ipsilateral renal agenesis) but the 27.6% of cases are of a rare variant of the syndrome (with uterus septum or cervical agenesis), showing relevant clinical and surgical implications. The extreme variability of anatomic structures involved in this syndrome (both uterus, cervico-vaginal and renal anomalies) is well known, even if a complete and uniform analysis of all its heterogeneous presentations in a large series is lacking. This is a retrospective study with 87 patients referred to our third level referral center between 1981 and 2011. We analyzed the laparoscopic and chart records of 87 women, who referred to our institute with double uterus, unilateral cervico-vaginal obstruction and ipsilateral renal anomalies. Sixty-three of 87 patients had the more classic variant of didelphys uterus with obstructed hemivagina; 10/87 patients had septate bicollis uterus with obstructed hemivagina; 9/87 patients had bicornuate bicollis uterus with obstructed hemivagina; 4/87 patients had didelphys uterus with unilateral cervical atresia; 1/87 patients had bicornuate uterus with one septate cervix and unilateral obstructed hemivagina. This is a retrospective study with a long enrolling period (30 years). New insights in the anatomic variants of this rare syndrome with their relevant surgical implications.

  11. Development of single chain variable fragment (scFv) antibodies against Xylella fastidiosa subsp. pauca by phage display.

    Science.gov (United States)

    Yuan, Qing; Jordan, Ramon; Brlansky, Ronald H; Istomina, Olga; Hartung, John

    2015-10-01

    Xylella fastidiosa is a member of the gamma proteobacteria. It is fastidious, insect-vectored and xylem-limited and causes a variety of diseases, some severe, on a wide range of economically important perennial crops, including grape and citrus. Antibody based detection assays are commercially available for X. fastidiosa, and are effective at the species, but not at the subspecies level. We have made a library of scFv antibody fragments directed against X. fastidiosa subsp. pauca strain 9a5c (citrus) by using phage display technology. Antibody gene repertoires were PCR-amplified using 23 primers for the heavy chain variable region (V(H)) and 21 primers for the light chain variable region (V(L)). The V(H) and V(L) were joined by overlap extension PCR, and then the genes of the scFv library were ligated into the phage vector pKM19. The library contained 1.2×10(7) independent clones with full-length scFv inserts. In each of 3cycles of affinity-selection with 9a5c, about 1.0×10(12) phage were used for panning with 4.1×10(6), 7.1×10(6), 2.1×10(7) phage recovered after the first, second and third cycles, respectively. Sixty-six percent of clones from the final library bound X. fastidiosa 9a5c in an ELISA. Some of these scFv antibodies recognized strain 9a5c and did not recognize X. fastidiosa strains that cause Pierce's disease of grapevine. Published by Elsevier B.V.

  12. Standardized anatomic space for abdominal fat quantification

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.

    2014-03-01

    The ability to accurately measure subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) from images is important for improved assessment and management of patients with various conditions such as obesity, diabetes mellitus, obstructive sleep apnea, cardiovascular disease, kidney disease, and degenerative disease. Although imaging and analysis methods to measure the volume of these tissue components have been developed [1, 2], in clinical practice, an estimate of the amount of fat is obtained from just one transverse abdominal CT slice typically acquired at the level of the L4-L5 vertebrae for various reasons including decreased radiation exposure and cost [3-5]. It is generally assumed that such an estimate reliably depicts the burden of fat in the body. This paper sets out to answer two questions related to this issue which have not been addressed in the literature. How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? At what anatomic location do the volumes of SAT and VAT correlate maximally with the corresponding single-slice area measures? To answer these questions, we propose two approaches for slice localization: linear mapping and non-linear mapping which is a novel learning based strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. We then study the volume-to-area correlations and determine where they become maximal. We demonstrate on 50 abdominal CT data sets that this mapping achieves significantly improved consistency of anatomic localization compared to current practice. Our results also indicate that maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized.

  13. A low-cost system for graphical process monitoring with colour video symbol display units

    International Nuclear Information System (INIS)

    Grauer, H.; Jarsch, V.; Mueller, W.

    1977-01-01

    A system for computer controlled graphic process supervision, using color symbol video displays is described. It has the following characteristics: - compact unit: no external memory for image storage - problem oriented simple descriptive cut to the process program - no restriction of the graphical representation of process variables - computer and display independent, by implementation of colours and parameterized code creation for the display. (WB) [de

  14. Early fetal anatomical sonography.

    LENUS (Irish Health Repository)

    Donnelly, Jennifer C

    2012-10-01

    Over the past decade, prenatal screening and diagnosis has moved from the second into the first trimester, with aneuploidy screening becoming both feasible and effective. With vast improvements in ultrasound technology, sonologists can now image the fetus in greater detail at all gestational ages. In the hands of experienced sonographers, anatomic surveys between 11 and 14 weeks can be carried out with good visualisation rates of many structures. It is important to be familiar with the normal development of the embryo and fetus, and to be aware of the major anatomical landmarks whose absence or presence may be deemed normal or abnormal depending on the gestational age. Some structural abnormalities will nearly always be detected, some will never be and some are potentially detectable depending on a number of factors.

  15. The linguistic roots of Modern English anatomical terminology.

    Science.gov (United States)

    Turmezei, Tom D

    2012-11-01

    Previous research focusing on Classical Latin and Greek roots has shown that understanding the etymology of English anatomical terms may be beneficial for students of human anatomy. However, not all anatomical terms are derived from Classical origins. This study aims to explore the linguistic roots of the Modern English terminology used in human gross anatomy. By reference to the Oxford English Dictionary, etymologies were determined for a lexicon of 798 Modern English gross anatomical terms from the 40(th) edition of Gray's Anatomy. Earliest traceable language of origin was determined for all 798 terms; language of acquisition was determined for 747 terms. Earliest traceable languages of origin were: Classical Latin (62%), Classical Greek (24%), Old English (7%), Post-Classical Latin (3%), and other (4%). Languages of acquisition were: Classical Latin (42%), Post-Classical Latin (29%), Old English (8%), Modern French (6%), Classical Greek (5%), Middle English (3%), and other (7%). While the roots of Modern English anatomical terminology mostly lie in Classical languages (accounting for the origin of 86% of terms), the anatomical lexicon of Modern English is actually much more diverse. Interesting and perhaps less familiar examples from these languages and the methods by which such terms have been created and absorbed are discussed. The author suggests that awareness of anatomical etymologies may enhance the enjoyment and understanding of human anatomy for students and teachers alike. Copyright © 2012 Wiley Periodicals, Inc.

  16. Anatomical influences on internally coupled ears in reptiles.

    Science.gov (United States)

    Young, Bruce A

    2016-10-01

    Many reptiles, and other vertebrates, have internally coupled ears in which a patent anatomical connection allows pressure waves generated by the displacement of one tympanic membrane to propagate (internally) through the head and, ultimately, influence the displacement of the contralateral tympanic membrane. The pattern of tympanic displacement caused by this internal coupling can give rise to novel sensory cues. The auditory mechanics of reptiles exhibit more anatomical variation than in any other vertebrate group. This variation includes structural features such as diverticula and septa, as well as coverings of the tympanic membrane. Many of these anatomical features would likely influence the functional significance of the internal coupling between the tympanic membranes. Several of the anatomical components of the reptilian internally coupled ear are under active motor control, suggesting that in some reptiles the auditory system may be more dynamic than previously recognized.

  17. High Resolution Displays Using NCAP Liquid Crystals

    Science.gov (United States)

    Macknick, A. Brian; Jones, Phil; White, Larry

    1989-07-01

    Nematic curvilinear aligned phase (NCAP) liquid crystals have been found useful for high information content video displays. NCAP materials are liquid crystals which have been encapsulated in a polymer matrix and which have a light transmission which is variable with applied electric fields. Because NCAP materials do not require polarizers, their on-state transmission is substantially better than twisted nematic cells. All dimensional tolerances are locked in during the encapsulation process and hence there are no critical sealing or spacing issues. By controlling the polymer/liquid crystal morphology, switching speeds of NCAP materials have been significantly improved over twisted nematic systems. Recent work has combined active matrix addressing with NCAP materials. Active matrices, such as thin film transistors, have given displays of high resolution. The paper will discuss the advantages of NCAP materials specifically designed for operation at video rates on transistor arrays; applications for both backlit and projection displays will be discussed.

  18. Perceptions of science. The anatomical mission to Burma.

    Science.gov (United States)

    Sappol, Michael

    2003-10-10

    Until the 1830s, most Americans were unfamiliar with the images of anatomy. Then a small vanguard of reformers and missionaries began to preach, at home and around the world, that an identification with the images and concepts of anatomy was a crucial part of the civilizing process. In his essay, Sappol charts the changes in the perception of self that resulted from this anatomical evangelism. Today, as anatomical images abound in the arts and the media, we still believe that anatomical images show us our inner reality.

  19. Designing a better weather display

    Science.gov (United States)

    Ware, Colin; Plumlee, Matthew

    2012-01-01

    The variables most commonly displayed on weather maps are atmospheric pressure, wind speed and direction, and surface temperature. But they are usually shown separately, not together on a single map. As a design exercise, we set the goal of finding out if it is possible to show all three variables (two 2D scalar fields and a 2D vector field) simultaneously such that values can be accurately read using keys for all variables, a reasonable level of detail is shown, and important meteorological features stand out clearly. Our solution involves employing three perceptual "channels", a color channel, a texture channel, and a motion channel in order to perceptually separate the variables and make them independently readable. We conducted an experiment to evaluate our new design both against a conventional solution, and against a glyph-based solution. The evaluation tested the abilities of novice subjects both to read values using a key, and to see meteorological patterns in the data. Our new scheme was superior especially in the representation of wind patterns using the motion channel, and it also performed well enough in the representation of pressure using the texture channel to suggest it as a viable design alternative.

  20. Uniportal anatomic combined unusual segmentectomies.

    Science.gov (United States)

    González-Rivas, Diego; Lirio, Francisco; Sesma, Julio

    2017-01-01

    Nowadays, sublobar anatomic resections are gaining momentum as a valid alternative for early stage lung cancer. Despite being technically demanding, anatomic segmentectomies can be performed by uniportal video-assisted thoracic surgery (VATS) approach to combine the benefits of minimally invasiveness with the maximum lung sparing. This procedure can be even more complex if a combined resection of multiple segments from different lobes has to be done. Here we report five cases of combined and unusual segmentectomies done by the same experienced surgeon in high volume institutions to show uniportal VATS is a feasible approach for these complex resections and to share an excellent educational resource.

  1. Mistakes in the usage of anatomical terminology in clinical practice.

    Science.gov (United States)

    Kachlik, David; Bozdechova, Ivana; Cech, Pavel; Musil, Vladimir; Baca, Vaclav

    2009-06-01

    Anatomical terminology serves as a basic communication tool in all the medical fields. Therefore Latin anatomical nomenclature has been repetitively issued and revised from 1895 (Basiliensia Nomina Anatomica) until 1998, when the last version was approved and published as the Terminologia Anatomica (International Anatomical Terminology) by the Federative Committee on Anatomical Terminology. A brief history of the terminology and nomenclature development is mentioned, along with the concept and contributions of the Terminologia Anatomica including the employed abbreviations. Examples of obsolete anatomical terms and their current synonyms are listed. Clinicians entered the process of the nomenclature revision and this aspect is demonstrated with several examples of terms used in clinical fields only, some already incorporated in the Terminologia Anatomica and a few obsolete terms still alive in non-theoretical communication. Frequent mistakes in grammar and orthography are stated as well. Authors of the article strongly recommend the use of the recent revision of the Latin anatomical nomenclature both in theoretical and clinical medicine.

  2. Network of anatomical texts (NAnaTex), an open-source project for visualizing the interaction between anatomical terms.

    Science.gov (United States)

    Momota, Ryusuke; Ohtsuka, Aiji

    2018-01-01

    Anatomy is the science and art of understanding the structure of the body and its components in relation to the functions of the whole-body system. Medicine is based on a deep understanding of anatomy, but quite a few introductory-level learners are overwhelmed by the sheer amount of anatomical terminology that must be understood, so they regard anatomy as a dull and dense subject. To help them learn anatomical terms in a more contextual way, we started a new open-source project, the Network of Anatomical Texts (NAnaTex), which visualizes relationships of body components by integrating text-based anatomical information using Cytoscape, a network visualization software platform. Here, we present a network of bones and muscles produced from literature descriptions. As this network is primarily text-based and does not require any programming knowledge, it is easy to implement new functions or provide extra information by making changes to the original text files. To facilitate collaborations, we deposited the source code files for the network into the GitHub repository ( https://github.com/ryusukemomota/nanatex ) so that anybody can participate in the evolution of the network and use it for their own non-profit purposes. This project should help not only introductory-level learners but also professional medical practitioners, who could use it as a quick reference.

  3. Anatomic features involved in technical complexity of partial nephrectomy.

    Science.gov (United States)

    Hou, Weibin; Yan, Weigang; Ji, Zhigang

    2015-01-01

    Nephrometry score systems, including RENAL nephrometry, preoperative aspects and dimensions used for an anatomical classification system, C-index, diameter-axial-polar nephrometry, contact surface area score, calculating resected and ischemized volume, renal tumor invasion index, surgical approach renal ranking score, zonal NePhRO score, and renal pelvic score, have been reviewed. Moreover, salient anatomic features like the perinephric fat and vascular variants also have been discussed. We then extract 7 anatomic characteristics, namely tumor size, spatial location, adjacency, exophytic/endophytic extension, vascular variants, pelvic anatomy, and perinephric fat as important features for partial nephrectomy. For novice surgeons, comprehensive and adequate anatomic consideration may help them in their early clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Anatomically-aided PET reconstruction using the kernel method.

    Science.gov (United States)

    Hutchcroft, Will; Wang, Guobao; Chen, Kevin T; Catana, Ciprian; Qi, Jinyi

    2016-09-21

    This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporates this information in the simpler maximum likelihood (ML) formulation and is amenable to ordered subsets. The new method also does not require any segmentation of the anatomical image to obtain edge information. We compare the kernel method with the Bowsher method for anatomically-aided PET image reconstruction through a simulated data set. Computer simulations demonstrate that the kernel method offers advantages over the Bowsher method in region of interest quantification. Additionally the kernel method is applied to a 3D patient data set. The kernel method results in reduced noise at a matched contrast level compared with the conventional ML expectation maximization algorithm.

  5. Anatomical Features and Early Outcomes of Endovascular Repair of Abdominal Aortic Aneurysm from a Korean Multicenter Registry.

    Science.gov (United States)

    Kwon, Hyunwook; Lee, Do Yun; Choi, Soo Jin Na; Park, Ki Hyuk; Min, Seung-Kee; Chang, Jeong-Hwan; Huh, Seung; Jeon, Yong Sun; Won, Jehwan; Byun, Seung Jae; Park, Sang Jun; Jang, Lee Chan; Kwon, Tae-Won

    2015-09-01

    To introduce a nation-based endovascular aneurysm repair (EVAR) registry in South Korea and to analyze the anatomical features and early clinical outcomes of abdominal aortic aneurysms (AAA) in patients who underwent EVAR. The Korean EVAR registry (KER) was a template-based online registry developed and established in 2009. The KER recruited 389 patients who underwent EVAR from 13 medical centers in South Korea from January 2010 to June 2010. We retrospectively reviewed the anatomic features and 30-day clinical outcomes. Initial deployment without open conversion was achieved in all cases and procedure-related 30-day mortality rate was 1.9%. Anatomic features showed the following variables: proximal aortic neck angle 48.8±25.7° (mean±standard deviation), vertical neck length 35.0±17.2 mm, aneurysmal sac diameter 57.2±14.2 mm, common iliac artery (CIA) involvement in 218 (56.3%) patients, and median right CIA length 34.9 mm. Two hundred and nineteen (56.3%) patients showed neck calcification, 98 patients (25.2%) had neck thrombus, and the inferior mesenteric arteries of 91 patients (23.4%) were occluded. Anatomical features of AAA in patients from the KER were characterized as having angulated proximal neck, tortuous iliac artery, and a higher rate of CIA involvement. Long-term follow-up and ongoing studies are required.

  6. Anatomical distribution of estrogen target neurons in turtle brain

    International Nuclear Information System (INIS)

    Kim, Y.S.; Stumpf, W.E.; Sar, M.

    1981-01-01

    Autoradiographic studies with [ 3 H]estradiol-17β in red-eared turtle (Pseudemys scripta elegans) show concentration and retention of radioactivity in nuclei of neurons in certain regions. Accumulations of estrogen target neurons exist in the periventricular brain with relationships to ventral extensions of the forebrain ventricles, including parolfactory, amygdaloid, septal, preoptic, hypothalamic and thalamic areas, as well as the dorsal ventricular ridge, the piriform cortex, and midbrain-pontine periaqueductal structures. The general anatomical pattern of distribution of estrogen target neurons corresponds to those observed not only in another reptile (Anolis carolinensis), but also in birds and mammals, as well as in teleosts and cyclostomes. In Pseudemys, which appears to display an intermediate degree of phylogenetic differentiation, the amygdaloid-septal-preoptic groups of estrogen target neurons constitute a continuum. In phylogenetic ascendency, e.g. in mammals, these cell populations are increasingly separated and distinct, while in phylogenetic descendency, e.g. in teleosts and cyclostomes, an amygdaloid group appears to be absent or contained within the septal-preoptic target cell population. (Auth.)

  7. Anatomical distribution of estrogen target neurons in turtle brain

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.S.; Stumpf, W.E.; Sar, M. (North Carolina Univ., Chapel Hill (USA))

    1981-12-28

    Autoradiographic studies with (/sup 3/H)estradiol-17..beta.. in red-eared turtle (Pseudemys scripta elegans) show concentration and retention of radioactivity in nuclei of neurons in certain regions. Accumulations of estrogen target neurons exist in the periventricular brain with relationships to ventral extensions of the forebrain ventricles, including parolfactory, amygdaloid, septal, preoptic, hypothalamic and thalamic areas, as well as the dorsal ventricular ridge, the piriform cortex, and midbrain-pontine periaqueductal structures. The general anatomical pattern of distribution of estrogen target neurons corresponds to those observed not only in another reptile (Anolis carolinensis), but also in birds and mammals, as well as in teleosts and cyclostomes. In Pseudemys, which appears to display an intermediate degree of phylogenetic differentiation, the amygdaloid-septal-preoptic groups of estrogen target neurons constitute a continuum. In phylogenetic ascendency, e.g. in mammals, these cell populations are increasingly separated and distinct, while in phylogenetic descendency, e.g. in teleosts and cyclostomes, an amygdaloid group appears to be absent or contained within the septal-preoptic target cell population.

  8. Anatomic and functional leg-length inequality: A review and recommendation for clinical decision-making. Part I, anatomic leg-length inequality: prevalence, magnitude, effects and clinical significance

    Directory of Open Access Journals (Sweden)

    Knutson Gary A

    2005-07-01

    Full Text Available Abstract Background Leg-length inequality is most often divided into two groups: anatomic and functional. Part I of this review analyses data collected on anatomic leg-length inequality relative to prevalence, magnitude, effects and clinical significance. Part II examines the functional "short leg" including anatomic-functional relationships, and provides an outline for clinical decision-making. Methods Online database – Medline, CINAHL and MANTIS – and library searches for the time frame of 1970–2005 were done using the term "leg-length inequality". Results and Discussion Using data on leg-length inequality obtained by accurate and reliable x-ray methods, the prevalence of anatomic inequality was found to be 90%, the mean magnitude of anatomic inequality was 5.2 mm (SD 4.1. The evidence suggests that, for most people, anatomic leg-length inequality does not appear to be clinically significant until the magnitude reaches ~ 20 mm (~3/4". Conclusion Anatomic leg-length inequality is near universal, but the average magnitude is small and not likely to be clinically significant.

  9. Analyzing Dental Implant Sites From Cone Beam Computed Tomography Scans on a Tablet Computer: A Comparative Study Between iPad and 3 Display Systems.

    Science.gov (United States)

    Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya

    2017-06-01

    The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.

  10. Unification of Sinonasal Anatomical Terminology

    Directory of Open Access Journals (Sweden)

    Voegels, Richard Louis

    2015-07-01

    Full Text Available The advent of endoscopy and computed tomography at the beginning of the 1980s brought to rhinology a revival of anatomy and physiology study. In 1994, the International Conference of Sinus Disease was conceived because the official “Terminologia Anatomica”[1] had little information on the detailed sinonasal anatomy. In addition, there was a lack of uniformity of terminology and definitions. After 20 years, a new conference has been held. The need to use the same terminology led to the publication by the European Society of Rhinology of the “European Position Paper on the Anatomical Terminology of the Internal Nose and Paranasal Sinuses,” that can be accessed freely at www.rhinologyjournal.com. Professor Valerie Lund et al[2] wrote this document reviewing the anatomical terms, comparing to the “Terminology Anatomica” official order to define the structures without eponyms, while respecting the embryological development and especially universalizing and simplifying the terms. A must-read! The text's purpose lies beyond the review of anatomical terminology to universalize the language used to refer to structures of the nasal and paranasal cavities. Information about the anatomy, based on extensive review of the current literature, is arranged in just over 50 pages, which are direct and to the point. The publication may be pleasant reading for learners and teachers of rhinology. This text can be a starting point and enables searching the universal terminology used in Brazil, seeking to converge with this new European proposal for a nomenclature to help us communicate with our peers in Brazil and the rest of the world. The original text of the European Society of Rhinology provides English terms that avoided the use of Latin, and thus fall beyond several national personal translations. It would be admirable if we created our own cross-cultural adaptation of this new suggested anatomical terminology.

  11. Anatomical variability in the cortical representation of first and second language.

    Science.gov (United States)

    Dehaene, S; Dupoux, E; Mehler, J; Cohen, L; Paulesu, E; Perani, D; van de Moortele, P F; Lehéricy, S; Le Bihan, D

    1997-12-01

    Functional magnetic resonance imaging was used to assess inter-subject variability in the cortical representation of language comprehension processes. Moderately fluent French-English bilinguals were scanned while they listened to stories in their first language (L1 = French) or in a second language (L2 = English) acquired at school after the age of seven. In all subjects, listening to L1 always activated a similar set of areas in the left temporal lobe, clustered along the left superior temporal sulcus. Listening to L2, however, activated a highly variable network of left and right temporal and frontal areas, sometimes restricted only to right-hemispheric regions. These results support the hypothesis that first language acquisition relies on a dedicated left-hemispheric cerebral network, while late second language acquisition is not necessarily associated with a reproducible biological substrate. The postulated contribution of the right hemisphere to L2 comprehension is found to hold only on average, individual subjects varying from complete right lateralization to standard left lateralization for L2.

  12. Improved algorithm for surface display from volumetric data

    International Nuclear Information System (INIS)

    Lobregt, S.; Schaars, H.W.G.K.; OpdeBeek, J.C.A.; Zonneveld, F.W.

    1988-01-01

    A high-resolution surface display is produced from three-dimensional datasets (computed tomography or magnetic resonance imaging). Unlike other voxel-based methods, this algorithm does not show a cuberille surface structure, because the surface orientation is calculated from original gray values. The applied surface shading is a function of local orientation and position of the surface and of a virtual light source, giving a realistic impression of the surface of bone and soft tissue. The projection and shading are table driven, combining variable viewpoint and illumination conditions with speed. Other options are cutplane gray-level display and surface transparency. Combined with volume scanning, this algorithm offers powerful application possibilities

  13. Anatomical terminology and nomenclature: past, present and highlights.

    Science.gov (United States)

    Kachlik, David; Baca, Vaclav; Bozdechova, Ivana; Cech, Pavel; Musil, Vladimir

    2008-08-01

    The anatomical terminology is a base for medical communication. It is elaborated into a nomenclature in Latin. Its history goes back to 1895, when the first Latin anatomical nomenclature was published as Basiliensia Nomina Anatomica. It was followed by seven revisions (Jenaiensia Nomina Anatomica 1935, Parisiensia Nomina Anatomica 1955, Nomina Anatomica 2nd to 6th edition 1960-1989). The last revision, Terminologia Anatomica, (TA) created by the Federative Committee on Anatomical Terminology and approved by the International Federation of Associations of Anatomists, was published in 1998. Apart from the official Latin anatomical terminology, it includes a list of recommended English equivalents. In this article, major changes and pitfalls of the nomenclature are discussed, as well as the clinical anatomy terms. The last revision (TA) is highly recommended to the attention of not only teachers, students and researchers, but also to clinicians, doctors, translators, editors and publishers to be followed in their activities.

  14. Extra-Anatomic Revascularization of Extensive Coral Reef Aorta.

    Science.gov (United States)

    Gaggiano, Andrea; Kasemi, Holta; Monti, Andrea; Laurito, Antonella; Maselli, Mauro; Manzo, Paola; Quaglino, Simone; Tavolini, Valeria

    2017-10-01

    Coral reef aorta (CRA) is a rare, potential lethal disease of the visceral aorta as it can cause visceral and renal infarction. Various surgical approaches have been proposed for the CRA treatment. The purpose of this article is to report different extensive extra-anatomic CRA treatment modalities tailored on the patients' clinical and anatomic presentation. From April 2006 to October 2012, 4 symptomatic patients with extensive CRA were treated at our department. Extra-anatomic aortic revascularization with selective visceral vessels clamping was performed in all cases. Technical success was 100%. No perioperative death was registered. All patients remained asymptomatic during the follow-up period (62, 49, 25, and 94 months, respectively), with bypasses and target vessels patency. The extra-anatomic bypass with selective visceral vessels clamping reduces the aortic occlusion time and the risk of organ ischemia. All approaches available should be considered on a case-by-case basis and in high-volume centers. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Reappraising the functional implications of the primate visual anatomical hierarchy.

    Science.gov (United States)

    Hegdé, Jay; Felleman, Daniel J

    2007-10-01

    The primate visual system has been shown to be organized into an anatomical hierarchy by the application of a few principled criteria. It has been widely assumed that cortical visual processing is also hierarchical, with the anatomical hierarchy providing a defined substrate for clear levels of hierarchical function. A large body of empirical evidence seemed to support this assumption, including the general observations that functional properties of visual neurons grow progressively more complex at progressively higher levels of the anatomical hierarchy. However, a growing body of evidence, including recent direct experimental comparisons of functional properties at two or more levels of the anatomical hierarchy, indicates that visual processing neither is hierarchical nor parallels the anatomical hierarchy. Recent results also indicate that some of the pathways of visual information flow are not hierarchical, so that the anatomical hierarchy cannot be taken as a strict flowchart of visual information either. Thus, while the sustaining strength of the notion of hierarchical processing may be that it is rather simple, its fatal flaw is that it is overly simplistic.

  16. Anatomic and Pathologic Variability During Radiotherapy for a Hybrid Active Breath-Hold Gating Technique

    International Nuclear Information System (INIS)

    Glide-Hurst, Carri K.; Gopan, Ellen; Hugo, Geoffrey D.

    2010-01-01

    Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroid position was 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.

  17. Linking retinotopic fMRI mapping and anatomical probability maps of human occipital areas V1 and V2.

    Science.gov (United States)

    Wohlschläger, A M; Specht, K; Lie, C; Mohlberg, H; Wohlschläger, A; Bente, K; Pietrzyk, U; Stöcker, T; Zilles, K; Amunts, K; Fink, G R

    2005-05-15

    Using functional MRI, we characterized field sign maps of the occipital cortex and created three-dimensional maps of these areas. By averaging the individual maps into group maps, probability maps of functionally defined V1 or V2 were determined and compared to anatomical probability maps of Brodmann areas BA17 and BA18 derived from cytoarchitectonic analysis (Amunts, K., Malikovic, A., Mohlberg, H., Schormann, T., Zilles, K., 2000. Brodmann's areas 17 and 18 brought into stereotaxic space-where and how variable? NeuroImage 11, 66-84). Comparison of areas BA17/V1 and BA18/V2 revealed good agreement of the anatomical and functional probability maps. Taking into account that our functional stimulation (due to constraints of the visual angle of stimulation achievable in the MR scanner) only identified parts of V1 and V2, for statistical evaluation of the spatial correlation of V1 and BA17, or V2 and BA18, respectively, the a priori measure kappa was calculated testing the hypothesis that a region can only be part of functionally defined V1 or V2 if it is also in anatomically defined BA17 or BA18, respectively. kappa = 1 means the hypothesis is fully true, kappa = 0 means functionally and anatomically defined visual areas are independent. When applying this measure to the probability maps, kappa was equal to 0.84 for both V1/BA17 and V2/BA18. The data thus show a good correspondence of functionally and anatomically derived segregations of early visual processing areas and serve as a basis for employing anatomical probability maps of V1 and V2 in group analyses to characterize functional activations of early visual processing areas.

  18. Inexpensive anatomical trainer for bronchoscopy.

    Science.gov (United States)

    Di Domenico, Stefano; Simonassi, Claudio; Chessa, Leonardo

    2007-08-01

    Flexible fiberoptic bronchoscopy is an indispensable tool for optimal management of intensive care unit patients. However, the acquisition of sufficient training in bronchoscopy is not straightforward during residency, because of technical and ethical problems. Moreover, the use of commercial simulators is limited by their high cost. In order to overcome these limitations, we realized a low-cost anatomical simulator to acquire and maintain the basic skill to perform bronchoscopy in ventilated patients. We used 1.5 mm diameter iron wire to construct the bronchial tree scaffold; glazier-putty was applied to create the anatomical model. The model was covered by several layers of newspaper strips previously immersed in water and vinilic glue. When the model completely dried up, it was detached from the scaffold by cutting it into six pieces, it was reassembled, painted and fitted with an endotracheal tube. We used very cheap material and the final cost was euro16. The trainer resulted in real-scale and anatomically accurate, with appropriate correspondence on endoscopic view between model and patients. All bronchial segments can be explored and easily identified by endoscopic and external vision. This cheap simulator is a valuable tool for practicing, particularly in a hospital with limited resources for medical training.

  19. Anatomical and functional outcomes of retinectomies in retinal detachments complicated by proliferative vitreoretinopathy

    Directory of Open Access Journals (Sweden)

    Mohammad Idrees Adhi

    2017-10-01

    Full Text Available Purpose: To study anatomical and functional outcomes of retinectomies in rhegmatogenous retinal detachments complicated by proliferative vitreoretinopathy. Methods: This is a retrospective interventional consecutive case series of eyes with rhegmatogenous retinal detachments complicated by advanced proliferative vitreoretinopathy and managed by relaxing retinectomy over a period of seventeen years. Three-port pars plana vitrectomy included core vitrectomy and removal of all epi-retinal membranes. On failure to flatten, retina was cut and excised. Basal vitrectomy and removal of anterior flap of retina then followed. Silicone oil was used as temponade in majority of cases. The dependent variables were anatomical and functional outcomes. The statistical analysis was performed on SPSS 21. Results: Series included 370 eyes of 337 patients. Mean follow up was 39 months. Scleral explant was used in 90(24.39% cases. Two hundred and nine (56.49% eyes were operated with trans conjunctival sutureless vitrectomy technique. Procedure was bilateral in 33 patients (09.79%. Retina attached in 311(84.05% eyes after initial surgery. Final re-attachment after one or more surgeries was achieved in 344(92.97% eyes. Two hundred and eleven (57.02% cases achieved visual acuity of 6/60 or better. Conclusion: Relaxing retinectomies have good and encouraging anatomical and functional outcomes. This surgery can be effectively carried out with trans conjunctival sutureless vitrectomy technique. Keywords: Retinotomy and retinectomy, Proliferative vitreoretinopathy, Trans conjunctival sutureless vitrectomy, Silicone oil

  20. Anatomically contoured plates for fixation of rib fractures.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  1. Anatomic mapping of molecular subtypes in diffuse glioma.

    Science.gov (United States)

    Tang, Qisheng; Lian, Yuxi; Yu, Jinhua; Wang, Yuanyuan; Shi, Zhifeng; Chen, Liang

    2017-09-15

    Tumor location served as an important prognostic factor in glioma patients was considered to postulate molecular features according to cell origin theory. However, anatomic distribution of unique molecular subtypes was not widely investigated. The relationship between molecular phenotype and histological subgroup were also vague based on tumor location. Our group focuses on the study of glioma anatomic location of distinctive molecular subgroups and histology subtypes, and explores the possibility of their consistency based on clinical background. We retrospectively reviewed 143 cases with both molecular information (IDH1/TERT/1p19q) and MRI images diagnosed as cerebral diffuse gliomas. The anatomic distribution was analyzed between distinctive molecular subgroups and its relationship with histological subtypes. The influence of tumor location, molecular stratification and histology diagnosis on survival outcome was investigated as well. Anatomic locations of cerebral diffuse glioma indicate varied clinical outcome. Based on that, it can be stratified into five principal molecular subgroups according to IDH1/TERT/1p19q status. Triple-positive (IDH1 and TERT mutation with 1p19q codeletion) glioma tended to be oligodendroglioma present with much better clinical outcome compared to TERT mutation only group who is glioblastoma inclined (median overall survival 39 months VS 18 months). Five molecular subgroups were demonstrated with distinctive locational distribution. This kind of anatomic feature is consistent with its corresponding histological subtypes. Each molecular subgroup in glioma has unique anatomic location which indicates distinctive clinical outcome. Molecular diagnosis can be served as perfect complementary tool for the precise diagnosis. Integration of histomolecular diagnosis will be much more helpful in routine clinical practice in the future.

  2. Anatomical variations between the sciatic nerve and the piriformis muscle: a contribution to surgical anatomy in piriformis syndrome.

    Science.gov (United States)

    Natsis, Konstantinos; Totlis, Trifon; Konstantinidis, George A; Paraskevas, George; Piagkou, Maria; Koebke, Juergen

    2014-04-01

    To detect the variable relationship between sciatic nerve and piriformis muscle and make surgeons aware of certain anatomical features of each variation that may be useful for the surgical treatment of the piriformis syndrome. The gluteal region of 147 Caucasian cadavers (294 limbs) was dissected. The anatomical relationship between the sciatic nerve and the piriformis muscle was recorded and classified according to the Beaton and Anson classification. The literature was reviewed to summarize the incidence of each variation. The sciatic nerve and piriformis muscle relationship followed the typical anatomical pattern in 275 limbs (93.6 %). In 12 limbs (4.1 %) the common peroneal nerve passed through and the tibial nerve below a double piriformis. In one limb (0.3 %) the common peroneal nerve coursed superior and the tibial nerve below the piriformis. In one limb (0.3 %) both nerves penetrated the piriformis. In one limb (0.3 %) both nerves passed above the piriformis. Four limbs (1.4 %) presented non-classified anatomical variations. When a double piriformis muscle was present, two different arrangements of the two heads were observed. Anatomical variations of the sciatic nerve around the piriformis muscle were present in 6.4 % of the limbs examined. When dissection of the entire piriformis is necessary for adequate sciatic nerve decompression, the surgeon should explore for the possible existence of a second tendon, which may be found either inferior or deep to the first one. Some rare, unclassified variations of the sciatic nerve should be expected during surgical intervention of the region.

  3. Anatomical Arrangement of the Subclavian Artery Branches in the Rabbit and European Hare

    Directory of Open Access Journals (Sweden)

    Maženský D.

    2017-12-01

    Full Text Available The aim of this study was to compare the anatomical arrangements of the branches arising from the subclavian arteries in the domesticated rabbit and hare. The study was carried out on ten adult rabbits and ten adult European hares using the corrosion cast technique. After the euthanasia, the vascular network was perfused with saline. The arterial system of the entire body was injected by Batson’s corrosion casting kit No. 17. After polymerization of the medium, the maceration was carried out in KOH solution. The arrangement of the origins of the branches of the bilateral subclavian arteries were more variable in the hare. The number of branches arising from the subclavian artery were more regular in the rabbit on the right side and in the hare on the left side. In the rabbit, we found in two cases, the origins of the branches of the left subclavian artery from the aortic arch. The anatomical found between the rabbit and the hare may possibly be associated with their different ways of life.

  4. Evolution of wood anatomical characters in Nepenthes and close relatives of Caryophyllales.

    Science.gov (United States)

    Schwallier, Rachel; Gravendeel, Barbara; de Boer, Hugo; Nylinder, Stephan; van Heuven, Bertie Joan; Sieder, Anton; Sumail, Sukaibin; van Vugt, Rogier; Lens, Frederic

    2017-05-01

    Nepenthes attracts wide attention with its spectacularly shaped carnivorous pitchers, cultural value and horticultural curiosity. Despite the plant's iconic fascination, surprisingly little anatomical detail is known about the genus beyond its modified leaf tip traps. Here, the wood anatomical diversity of Nepenthes is explored. This diversity is further assessed with a phylogenetic framework to investigate whether the wood characters within the genus are relevant from an evolutionary or ecological perspective, or rather depend on differences in developmental stages, growth habits, substrates or precipitation. Observations were performed using light microscopy and scanning electron microscopy. Ancestral states of selected wood and pith characters were reconstructed using an existing molecular phylogeny for Nepenthes and a broader Caryophyllales framework. Pairwise comparisons were assessed for possible relationships between wood anatomy and developmental stages, growth habits, substrates and ecology. Wood anatomy of Nepenthes is diffuse porous, with mainly solitary vessels showing simple, bordered perforation plates and alternate intervessel pits, fibres with distinctly bordered pits (occasionally septate), apotracheal axial parenchyma and co-occurring uni- and multiseriate rays often including silica bodies. Precipitation and growth habit (stem length) are linked with vessel density and multiseriate ray height, while soil type correlates with vessel diameter, vessel element length and maximum ray width. For Caryophyllales as a whole, silica grains, successive cambia and bordered perforation plates are the result of convergent evolution. Peculiar helical sculpturing patterns within various cell types occur uniquely within the insectivorous clade of non-core Caryophyllales. The wood anatomical variation in Nepenthes displays variation for some characters dependent on soil type, precipitation and stem length, but is largely conservative. The helical-banded fibre

  5. Reproductive phase determination in male meagre (Argyrosomus regius, Sciaenidae: testis development and histologic corroboration of a gross anatomical scale

    Directory of Open Access Journals (Sweden)

    Nuno Prista

    2014-03-01

    Full Text Available Reproductive stage determination of male gonads has received sparse attention in fish biology literature with few studies detailing the building of gross anatomical- and histologic scales. The meagre (Argyrosomus regius is one of the world’s largest sciaenids and supports a significant regional fishery in European and North African waters whose reproductive patterns are yet to be fully investigated. In the present study, we derive a macroscopic grading system for meagre testis using semi-quantitative graphs that feature the testis variability along the species size range and time of the year. We then describe the histological stages and reproductive phases of male testes and determine the extent to which they corroborate the anatomical scale. Our results indicate that gross anatomical analyses are accurate in assessments of the meagre spawning season but may not precisely distinguish the testes of well-mature fish and first spawning virgins. Furthermore, we show that milt expression varies widely with size and misclassifies as immature many smaller fish in spawning-capable condition. We discuss these findings in terms of their contribution to the understanding of testes development and the uncertainties involved in determining the size-at-maturity of male fish using gross anatomical scales.

  6. Wavelet-based resolution recovery using an anatomical prior provides quantitative recovery for human population phantom PET [11C]raclopride data

    International Nuclear Information System (INIS)

    Shidahara, M; Tamura, H; Tsoumpas, C; McGinnity, C J; Hammers, A; Turkheimer, F E; Kato, T; Watabe, H

    2012-01-01

    The objective of this study was to evaluate a resolution recovery (RR) method using a variety of simulated human brain [ 11 C]raclopride positron emission tomography (PET) images. Simulated datasets of 15 numerical human phantoms were processed by a wavelet-based RR method using an anatomical prior. The anatomical prior was in the form of a hybrid segmented atlas, which combined an atlas for anatomical labelling and a PET image for functional labelling of each anatomical structure. We applied RR to both 60 min static and dynamic PET images. Recovery was quantified in 84 regions, comparing the typical ‘true’ value for the simulation, as obtained in normal subjects, simulated and RR PET images. The radioactivity concentration in the white matter, striatum and other cortical regions was successfully recovered for the 60 min static image of all 15 human phantoms; the dependence of the solution on accurate anatomical information was demonstrated by the difficulty of the technique to retrieve the subthalamic nuclei due to mismatch between the two atlases used for data simulation and recovery. Structural and functional synergy for resolution recovery (SFS-RR) improved quantification in the caudate and putamen, the main regions of interest, from −30.1% and −26.2% to −17.6% and −15.1%, respectively, for the 60 min static image and from −51.4% and −38.3% to −27.6% and −20.3% for the binding potential (BP ND ) image, respectively. The proposed methodology proved effective in the RR of small structures from brain [ 11 C]raclopride PET images. The improvement is consistent across the anatomical variability of a simulated population as long as accurate anatomical segmentations are provided. (paper)

  7. Connecting imaging mass spectrometry and magnetic resonance imaging-based anatomical atlases for automated anatomical interpretation and differential analysis.

    Science.gov (United States)

    Verbeeck, Nico; Spraggins, Jeffrey M; Murphy, Monika J M; Wang, Hui-Dong; Deutch, Ariel Y; Caprioli, Richard M; Van de Plas, Raf

    2017-07-01

    Imaging mass spectrometry (IMS) is a molecular imaging technology that can measure thousands of biomolecules concurrently without prior tagging, making it particularly suitable for exploratory research. However, the data size and dimensionality often makes thorough extraction of relevant information impractical. To help guide and accelerate IMS data analysis, we recently developed a framework that integrates IMS measurements with anatomical atlases, opening up opportunities for anatomy-driven exploration of IMS data. One example is the automated anatomical interpretation of ion images, where empirically measured ion distributions are automatically decomposed into their underlying anatomical structures. While offering significant potential, IMS-atlas integration has thus far been restricted to the Allen Mouse Brain Atlas (AMBA) and mouse brain samples. Here, we expand the applicability of this framework by extending towards new animal species and a new set of anatomical atlases retrieved from the Scalable Brain Atlas (SBA). Furthermore, as many SBA atlases are based on magnetic resonance imaging (MRI) data, a new registration pipeline was developed that enables direct non-rigid IMS-to-MRI registration. These developments are demonstrated on protein-focused FTICR IMS measurements from coronal brain sections of a Parkinson's disease (PD) rat model. The measurements are integrated with an MRI-based rat brain atlas from the SBA. The new rat-focused IMS-atlas integration is used to perform automated anatomical interpretation and to find differential ions between healthy and diseased tissue. IMS-atlas integration can serve as an important accelerator in IMS data exploration, and with these new developments it can now be applied to a wider variety of animal species and modalities. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann. Copyright © 2017. Published by Elsevier B.V.

  8. Automatic anatomically selective image enhancement in digital chest radiography

    International Nuclear Information System (INIS)

    Sezan, M.I.; Minerbo, G.N.; Schaetzing, R.

    1989-01-01

    The authors develop a technique for automatic anatomically selective enhancement of digital chest radiographs. Anatomically selective enhancement is motivated by the desire to simultaneously meet the different enhancement requirements of the lung field and the mediastinum. A recent peak detection algorithm and a set of rules are applied to the image histogram to determine automatically a gray-level threshold between the lung field and mediastinum. The gray-level threshold facilitates anatomically selective gray-scale modification and/or unsharp masking. Further, in an attempt to suppress possible white-band or black-band artifacts due to unsharp masking at sharp edges, local-contrast adaptivity is incorporated into anatomically selective unsharp masking by designing an anatomy-sensitive emphasis parameter which varies asymmetrically with positive and negative values of the local image contrast

  9. CT following US for possible appendicitis: anatomic coverage

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Martin E. [University of Toronto, Princess Margaret Hospital, 3-920, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Alharbi, Fawaz [University of Toronto, Toronto General Hospital, NCSB 1C572, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Qassim University, Department of Medical Imaging, Buraydah, Qassim (Saudi Arabia); Chawla, Tanya P. [University of Toronto, Mount Sinai Hospital, Room 567, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Moshonov, Hadas [University of Toronto, Joint Department of Medical Imaging, Toronto, Ontario (Canada)

    2016-02-15

    To determine superior-inferior anatomic borders for CT following inconclusive/nondiagnostic US for possible appendicitis. Ninety-nine patients with possible appendicitis and inconclusive/nondiagnostic US followed by CT were included in this retrospective study. Two radiologists reviewed CT images and determined superior-inferior anatomic borders required to diagnose or exclude appendicitis and diagnose alternative causes. This ''targeted'' coverage was used to estimate potential reduction in anatomic coverage compared to standard abdominal/pelvic CT. The study group included 83 women and 16 men; mean age 32 (median, 29; range 18-73) years. Final diagnoses were: nonspecific abdominal pain 50/99 (51 %), appendicitis 26/99 (26 %), gynaecological 12/99 (12 %), gastrointestinal 9/99 (10 %), and musculoskeletal 2/99 (2 %). Median dose-length product for standard CT was 890.0 (range, 306.3 - 2493.9) mGy.cm. To confidently diagnose/exclude appendicitis or identify alternative diagnoses, maximum superior-inferior anatomic CT coverage was the superior border of L2-superior border of pubic symphysis, for both reviewers. Targeted CT would reduce anatomic coverage by 30-55 % (mean 39 %, median 40 %) compared to standard CT. When CT is performed for appendicitis following inconclusive/nondiagnostic US, targeted CT from the superior border of L2-superior border of pubic symphysis can be used resulting in significant reduction in exposure to ionizing radiation compared to standard CT. (orig.)

  10. CT following US for possible appendicitis: anatomic coverage

    International Nuclear Information System (INIS)

    O'Malley, Martin E.; Alharbi, Fawaz; Chawla, Tanya P.; Moshonov, Hadas

    2016-01-01

    To determine superior-inferior anatomic borders for CT following inconclusive/nondiagnostic US for possible appendicitis. Ninety-nine patients with possible appendicitis and inconclusive/nondiagnostic US followed by CT were included in this retrospective study. Two radiologists reviewed CT images and determined superior-inferior anatomic borders required to diagnose or exclude appendicitis and diagnose alternative causes. This ''targeted'' coverage was used to estimate potential reduction in anatomic coverage compared to standard abdominal/pelvic CT. The study group included 83 women and 16 men; mean age 32 (median, 29; range 18-73) years. Final diagnoses were: nonspecific abdominal pain 50/99 (51 %), appendicitis 26/99 (26 %), gynaecological 12/99 (12 %), gastrointestinal 9/99 (10 %), and musculoskeletal 2/99 (2 %). Median dose-length product for standard CT was 890.0 (range, 306.3 - 2493.9) mGy.cm. To confidently diagnose/exclude appendicitis or identify alternative diagnoses, maximum superior-inferior anatomic CT coverage was the superior border of L2-superior border of pubic symphysis, for both reviewers. Targeted CT would reduce anatomic coverage by 30-55 % (mean 39 %, median 40 %) compared to standard CT. When CT is performed for appendicitis following inconclusive/nondiagnostic US, targeted CT from the superior border of L2-superior border of pubic symphysis can be used resulting in significant reduction in exposure to ionizing radiation compared to standard CT. (orig.)

  11. [Project HRANAFINA--Croatian anatomical and physiological terminology].

    Science.gov (United States)

    Vodanović, Marin

    2012-01-01

    HRANAFINA--Croatian Anatomical and Physiological Terminology is a project of the University of Zagreb School of Dental Medicine funded by the Croatian Science Foundation. It is performed in cooperation with other Croatian universities with medical schools. This project has a two-pronged aim: firstly, building of Croatian anatomical and physiological terminology and secondly, Croatian anatomical and physiological terminology usage popularization between health professionals, medical students, scientists and translators. Internationally recognized experts from Croatian universities with medical faculties and linguistics experts are involved in the project. All project activities are coordinated in agreement with the National Coordinator for Development of Croatian Professional Terminology. The project enhances Croatian professional terminology and Croatian language in general, increases competitiveness of Croatian scientists on international level and facilitates the involvement of Croatian scientists, health care providers and medical students in European projects.

  12. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  13. Anatomical entity recognition with a hierarchical framework augmented by external resources.

    Directory of Open Access Journals (Sweden)

    Yan Xu

    Full Text Available References to anatomical entities in medical records consist not only of explicit references to anatomical locations, but also other diverse types of expressions, such as specific diseases, clinical tests, clinical treatments, which constitute implicit references to anatomical entities. In order to identify these implicit anatomical entities, we propose a hierarchical framework, in which two layers of named entity recognizers (NERs work in a cooperative manner. Each of the NERs is implemented using the Conditional Random Fields (CRF model, which use a range of external resources to generate features. We constructed a dictionary of anatomical entity expressions by exploiting four existing resources, i.e., UMLS, MeSH, RadLex and BodyPart3D, and supplemented information from two external knowledge bases, i.e., Wikipedia and WordNet, to improve inference of anatomical entities from implicit expressions. Experiments conducted on 300 discharge summaries showed a micro-averaged performance of 0.8509 Precision, 0.7796 Recall and 0.8137 F1 for explicit anatomical entity recognition, and 0.8695 Precision, 0.6893 Recall and 0.7690 F1 for implicit anatomical entity recognition. The use of the hierarchical framework, which combines the recognition of named entities of various types (diseases, clinical tests, treatments with information embedded in external knowledge bases, resulted in a 5.08% increment in F1. The resources constructed for this research will be made publicly available.

  14. The Anatomic Midpoint of the Attachment of the Medial Patellofemoral Complex.

    Science.gov (United States)

    Tanaka, Miho J; Voss, Andreas; Fulkerson, John P

    2016-07-20

    The medial patellofemoral ligament varies in attachment of its fibers to the patella and vastus intermedius tendon. Our aim was to identify and describe its anatomic midpoint. To account for the variability of the attachment site, we refer to it as the medial patellofemoral complex. Using AutoCAD software, we identified the midpoint of the medial patellofemoral complex attachment on photographs of 31 cadaveric knee dissections. The midpoint was referenced relative to the superior articular surface of the patella (P1) and was described in terms of the percentage of the patellar articular length distal to this point. A second point, at the junction of the medial border of the vastus intermedius tendon with the superior articular border of the patella, was identified (P2). The distances of the midpoint to P1 and P2 were calculated and were compared using paired t tests. Twenty-five images had appropriate quality and landmarks for digital analysis. The midpoint of the medial patellofemoral complex was located a mean (and standard deviation) of 2.3% ± 15.8% of the patellar articular length distal to the superior pole and was at or proximal to P1 in 12 knees. In all knees, the midpoint was at or proximal to P2. After exclusion of 2 knees with vastus intermedius tendon attachments only, the medial patellofemoral complex midpoint was closer to P2 (5.3% ± 8.6% of the patellar articular length) than to P1 (9.3% ± 8.5% of the patellar articular length) (p = 0.06). The midpoint of the medial patellofemoral complex was 2.3% of the articular length distal to the superior pole of the patella. Additionally, we describe an anatomic landmark at the junction of the medial border of the vastus intermedius tendon and the articular border of the patella that approximates the midpoint of this complex. Our study shows that the anatomic midpoint of the attachment of the medial patellofemoral complex is proximal to the junction of the medial vastus intermedius tendon and the articular

  15. Morpho-anatomical investigations on Momordica charantia L. (Cucurbitaceae

    Directory of Open Access Journals (Sweden)

    İlham Eröz Poyraz

    2016-05-01

    Full Text Available Momordica charantia L. (Cucurbitaceae used for some medicinal purposes like antidiabetic, anticancer, antiviral and treat to gastritis was investigated. Morphological studies were supported by morphometric measurements and drawings of male and female flowers, fruit and seeds of the species. In anatomical studies, cross sections of stem and leaf, upper and lower surface sections of leaves were evaluated. It was detected that the stem with typical anatomical properties of a climbing dicotyl plant. The leaves were amphistotamic and with lots of cyctoliths on the lower surface of leaves. Stomata are anomocytic and situated much more at the lower surface of leaves. Morpho-anatomical investigations on Momordica charantia L. (Cucurbitaceae*

  16. Sexual Dimorphisms of Appendicular Musculoskeletal Morphology Related to Social Display in Cuban Anolis Lizards.

    Science.gov (United States)

    Anzai, Wataru; Cádiz, Antonio; Endo, Hideki

    2015-10-01

    In Anolis lizards, sexual dimorphism has been reported in morphological and ecological traits. Males show larger body size and longer limbs related to territorial combat and courtship display with the dewlap. Although functional-anatomical traits are closely related to locomotor behaviors, differences between sexes in musculoskeletal traits on limbs remain unclear. We explored the relationships among sexual dimorphisms in musculoskeletal morphology, habitat, and locomotor traits in Anolis lizards. Specifically, we examined appendicular musculoskeletal morphology in three species of Cuban Anolis by measuring muscle mass and lengths of moment arms. Through comparisons of crossing locomotion, we found that the runner species possessed larger extensors in hindlimbs, which are advantageous for running, whereas the masses of the humeral and femoral retractors were larger in climber species, allowing these lizards to hold up their bodies and occupy tree substrates. Comparisons between the sexes showed different trends among the three species. Males of A. porcatus, which inhabit narrow branches or leaves, had stronger elbow extensors that maintain the display posture. In contrast, males of A. sagrei, which occupy broad surfaces, did not show sexual differences that affected social display. Moreover, A. bartschi indicated sexual differences despite the absence of dewlapping behavior. Our findings suggest that both sexes show fundamentally similar relationships between muscular morphology and locomotor habits to adapt arboreal or terrestrial substrates, and yet sexual dimorphism in forelimb muscles may additionally affected by male specific display with the dewlap.

  17. Generation of a Highly Reactive Chicken-Derived Single-Chain Variable Fragment against Fusarium verticillioides by Phage Display

    Directory of Open Access Journals (Sweden)

    Zu-Quan Hu

    2012-06-01

    Full Text Available Fusarium verticillioides is the primary causal agent of Fusarium ear and kernel rot in maize, producing fumonisin mycotoxins that are toxic to humans and domestic animals. Rapid detection and monitoring of fumonisin-producing fungi are pivotally important for the prevention of mycotoxins from entering into food/feed products. Chicken-derived single-chain variable fragments (scFvs against cell wall-bound proteins from F. verticillioides were isolated from an immunocompetent phage display library. Comparative phage enzyme-linked immunosorbant assays (ELISAs and sequencing analyses identified four different scFv antibodies with high sensitivity. Soluble antibody ELISAs identified two highly sensitive scFv antibodies, FvCA3 and FvCA4, with the latter being slightly more sensitive. Three-dimensional modeling revealed that the FvCA4 may hold a better overall structure with CDRH3, CDRL1 and CDRL3 centered in the core region of antibody surface compared with that of other scFvs. Immunofluorescence labeling revealed that the binding of FvCA4 antibody was localized to the cell walls of conidiospores and hyphae of F. verticillioides, confirming the specificity of this antibody for a surface target. This scFv antibody was able to detect the fungal mycelium as low as 10−2 μg/mL and contaminating mycelium at a quantity of 10−2 mg/g maize. This is the first report that scFv antibodies derived from phage display have a wide application for rapid and accurate detection and monitoring of fumonisin-producing pathogens in agricultural samples.

  18. Advanced Transport Operating System (ATOPS) control display unit software description

    Science.gov (United States)

    Slominski, Christopher J.; Parks, Mark A.; Debure, Kelly R.; Heaphy, William J.

    1992-01-01

    The software created for the Control Display Units (CDUs), used for the Advanced Transport Operating Systems (ATOPS) project, on the Transport Systems Research Vehicle (TSRV) is described. Module descriptions are presented in a standardized format which contains module purpose, calling sequence, a detailed description, and global references. The global reference section includes subroutines, functions, and common variables referenced by a particular module. The CDUs, one for the pilot and one for the copilot, are used for flight management purposes. Operations performed with the CDU affects the aircraft's guidance, navigation, and display software.

  19. Neural, electrophysiological and anatomical basis of brain-network variability and its characteristic changes in mental disorders.

    Science.gov (United States)

    Zhang, Jie; Cheng, Wei; Liu, Zhaowen; Zhang, Kai; Lei, Xu; Yao, Ye; Becker, Benjamin; Liu, Yicen; Kendrick, Keith M; Lu, Guangming; Feng, Jianfeng

    2016-08-01

    SEE MATTAR ET AL DOI101093/AWW151 FOR A SCIENTIFIC COMMENTARY ON THIS ARTICLE: Functional brain networks demonstrate significant temporal variability and dynamic reconfiguration even in the resting state. Currently, most studies investigate temporal variability of brain networks at the scale of single (micro) or whole-brain (macro) connectivity. However, the mechanism underlying time-varying properties remains unclear, as the coupling between brain network variability and neural activity is not readily apparent when analysed at either micro or macroscales. We propose an intermediate (meso) scale analysis and characterize temporal variability of the functional architecture associated with a particular region. This yields a topography of variability that reflects the whole-brain and, most importantly, creates an analytical framework to establish the fundamental relationship between variability of regional functional architecture and its neural activity or structural connectivity. We find that temporal variability reflects the dynamical reconfiguration of a brain region into distinct functional modules at different times and may be indicative of brain flexibility and adaptability. Primary and unimodal sensory-motor cortices demonstrate low temporal variability, while transmodal areas, including heteromodal association areas and limbic system, demonstrate the high variability. In particular, regions with highest variability such as hippocampus/parahippocampus, inferior and middle temporal gyrus, olfactory gyrus and caudate are all related to learning, suggesting that the temporal variability may indicate the level of brain adaptability. With simultaneously recorded electroencephalography/functional magnetic resonance imaging and functional magnetic resonance imaging/diffusion tensor imaging data, we also find that variability of regional functional architecture is modulated by local blood oxygen level-dependent activity and α-band oscillation, and is governed by the

  20. ANATOMIC STRUCTURE OF CAMPANULA ROTUNDIFOLIA L. GRASS

    Directory of Open Access Journals (Sweden)

    V. N. Bubenchikova

    2017-01-01

    Full Text Available The article present results of the study for a anatomic structure of Campanula rotundifolia grass from Campanulaceae family. Despite its dispersion and application in folk medicine, there are no data about its anatomic structure, therefore to estimate the indices of authenticity and quality of raw materials it is necessary to develop microdiagnostical features in the first place, which could help introducing of thisplant in a medical practice. The purpose of this work is to study anatomical structureof Campanula rotundifolia grass to determine its diagnostic features. Methods. Thestudy for anatomic structure was carried out in accordance with the requirements of State Pharmacopoeia, edition XIII. Micromed laboratory microscope with digital adjutage was used to create microphotoes, Photoshop CC was used for their processing. Result. We have established that stalk epidermis is prosenchymal, slightly winding with straight of splayed end cells. After study for the epidermis cells we established that upper epidermis cells had straight walls and are slightly winding. The cells of lower epidermishave more winding walls with prolong wrinkled cuticule. Presence of simple one-cell, thin wall, rough papillose hair on leaf and stalk epidermis. Cells of epidermis in fauces of corolla are prosenchymal, with winding walls, straight or winding walls in a cup. Papillary excrescences can be found along the cup edges. Stomatal apparatus is anomocytic. Conclusion. As the result of the study we have carried out the research for Campanula rotundifolia grass anatomic structure, and determined microdiagnostic features for determination of raw materials authenticity, which included presence of simple, one-cell, thin-walled, rough papillose hair on both epidermises of a leaf, along the veins, leaf edge, and stalk epidermis, as well as the presence of epidermis cells with papillary excrescences along the edges of leaves and cups. Intercellular canals are situatedalong the

  1. [Cellular subcutaneous tissue. Anatomic observations].

    Science.gov (United States)

    Marquart-Elbaz, C; Varnaison, E; Sick, H; Grosshans, E; Cribier, B

    2001-11-01

    We showed in a companion paper that the definition of the French "subcutaneous cellular tissue" considerably varied from the 18th to the end of the 20th centuries and has not yet reached a consensus. To address the anatomic reality of this "subcutaneous cellular tissue", we investigated the anatomic structures underlying the fat tissue in normal human skin. Sixty specimens were excised from the surface to the deep structures (bone, muscle, cartilage) on different body sites of 3 cadavers from the Institut d'Anatomie Normale de Strasbourg. Samples were paraffin-embedded, stained and analysed with a binocular microscope taking x 1 photographs. Specimens were also excised and fixed after subcutaneous injection of Indian ink, after mechanic tissue splitting and after performing artificial skin folds. The aspects of the deep parts of the skin greatly varied according to their anatomic localisation. Below the adipose tissue, we often found a lamellar fibrous layer which extended from the interlobular septa and contained horizontally distributed fat cells. No specific tissue below the hypodermis was observed. Artificial skin folds concerned either exclusively the dermis, when they were superficial or included the hypodermis, but no specific structure was apparent in the center of the fold. India ink diffused to the adipose tissue, mainly along the septa, but did not localise in a specific subcutaneous compartment. This study shows that the histologic aspects of the deep part of the skin depend mainly on the anatomic localisation. Skin is composed of epidermis, dermis and hypodermis and thus the hypodermis can not be considered as being "subcutaneous". A difficult to individualise, fibrous lamellar structure in continuity with the interlobular septa is often found under the fat lobules. This structure is a cleavage line, as is always the case with loose connective tissues, but belongs to the hypodermis (i.e. fat tissue). No specific tissue nor any virtual space was

  2. Experimental evaluation of a perspective tunnel display for three-dimensional helicopter approaches

    Science.gov (United States)

    Grunwald, A. J.; Robertson, J. B.; Hatfield, J. J.

    1981-01-01

    A computer-generated perspective tunnel display for a steep and strongly curved three-dimensional helicopter approach is studied. The necessary control variables for following a curved trajectory are analyzed, the effectiveness of superimposed predictor symbology is investigated, and a suitable predictor law is formulated. The theoretical considerations are validated by an extensive fixed-base simulator program. The tunnel display with a superimposed predictor symbol is shown to outperform conventional-type displays in its abilities to follow a curved trajectory in the presence of gust disturbances, to enter the trajectory from an unknown position outside this trajectory, as well as to monitor automatic approaches. The feasibility of the tunnel display for operation in actual flight has been demonstrated in an exploratory flight test.

  3. Automatic, anatomically selective, artifact-free enhancement of digital chest radiographs

    International Nuclear Information System (INIS)

    Sezan, M.I.; Tekalp, A.M.; Schaetzing, R.

    1988-01-01

    The authors propose a technique for automatic, anatomically selective, artifact-free enhancement of digital chest radiographs. Anatomically selective enhancement is motivated by the different enhancement requirements of the lung field and the mediastinum. A recent peak detection algorithm is applied to the image histogram to automatically determine a gray-level threshold between the lung and mediastinum fields. The gray-level threshold facilitates anatomically selective gray-scale modification and unsharp masking. Further, in an attempt to suppress possible white-band artifacts due to unsharp masking at sharp edges, local-contrast adaptivity is incorporated into anatomically selective unsharp masking by designing an anatomy-sensitive emphasis parameter that varied asymmetrically with positive and negative values of the local image contrast

  4. A head-mounted display system for augmented reality: Initial evaluation for interventional MRI

    International Nuclear Information System (INIS)

    Wendt, M.; Wacker, F.K.

    2003-01-01

    Purpose: To discuss the technical details of a head mounted display with an augmented reality (AR) system and to describe a first pre-clinical evaluation in interventional MRI. Method: The AR system consists of a video-see-through head mounted display (HMD), mounted with a mini video camera for tracking and a stereo pair of mini cameras that capture live images of the scene. The live video view of the phantom/patient is augmented with graphical representations of anatomical structures from MRI image data and is displayed on the HMD. The application of the AR system with interventional MRI was tested using a MRI data set of the head and a head phantom. Results: The HMD enables the user to move around and observe the scene dynamically from various viewpoints. Within a short time the natural hand-eye coordination can easily be adapted to the slightly different view. The 3D perception is based on stereo and kinetic depth cues. A circular target with a diameter of 0.5 square centimeter was hit in 19 of 20 attempts. In a first evaluation the MRI image data augmented reality scene of a head phantom allowed good planning and precise simulation of a puncture. Conclusion: The HMD in combination with AR provides a direct, intuitive guidance for interventional MR procedures. (orig.) [de

  5. A Reinforcement-Based Learning Paradigm Increases Anatomical Learning and Retention-A Neuroeducation Study.

    Science.gov (United States)

    Anderson, Sarah J; Hecker, Kent G; Krigolson, Olave E; Jamniczky, Heather A

    2018-01-01

    In anatomy education, a key hurdle to engaging in higher-level discussion in the classroom is recognizing and understanding the extensive terminology used to identify and describe anatomical structures. Given the time-limited classroom environment, seeking methods to impart this foundational knowledge to students in an efficient manner is essential. Just-in-Time Teaching (JiTT) methods incorporate pre-class exercises (typically online) meant to establish foundational knowledge in novice learners so subsequent instructor-led sessions can focus on deeper, more complex concepts. Determining how best do we design and assess pre-class exercises requires a detailed examination of learning and retention in an applied educational context. Here we used electroencephalography (EEG) as a quantitative dependent variable to track learning and examine the efficacy of JiTT activities to teach anatomy. Specifically, we examined changes in the amplitude of the N250 and reward positivity event-related brain potential (ERP) components alongside behavioral performance as novice students participated in a series of computerized reinforcement-based learning modules to teach neuroanatomical structures. We found that as students learned to identify anatomical structures, the amplitude of the N250 increased and reward positivity amplitude decreased in response to positive feedback. Both on a retention and transfer exercise when learners successfully remembered and translated their knowledge to novel images, the amplitude of the reward positivity remained decreased compared to early learning. Our findings suggest ERPs can be used as a tool to track learning, retention, and transfer of knowledge and that employing the reinforcement learning paradigm is an effective educational approach for developing anatomical expertise.

  6. Longitudinal shapes of the tibia and femur are unrelated and variable.

    Science.gov (United States)

    Howell, Stephen M; Kuznik, Kyle; Hull, Maury L; Siston, Robert A

    2010-04-01

    In general practice, short films of the knee are used to assess component position and define the entry point for intramedullary femoral alignment in TKAs; however, whether it is justified to use the short film commonly used in research settings and everyday practice as a substitute for the whole leg view is controversial and needs clarification. In 138 long leg CT scanograms we measured the angle formed by the anatomic axis of the proximal fourth of the tibia and the mechanical axis of the tibia, the angle formed by the anatomic axis of the distal fourth of the femur and the mechanical axis of the femur, the "bow" of the tibia (as reflected by the offset of the anatomic axis from the center of the talus), and the "bow" of the femur (as reflected by the offset of the anatomic axis from the center of the femoral head). Because the angle formed by these axes and the bow of the tibia and femur have wide variability in females and males, a short film of the knee should not be used in place of the whole leg view when accurate assessment of component position and limb alignment is essential. A previous study of normal limbs found that only 2% of subjects have a neutral hip-knee-ankle axis, which can be explained by the wide variability of the bow in the tibia and femur and the lack of correlation between the bow of the tibia and femur in a given limb as shown in the current study.

  7. Nogo receptor 1 limits tactile task performance independent of basal anatomical plasticity.

    Directory of Open Access Journals (Sweden)

    Jennifer I Park

    Full Text Available The genes that govern how experience refines neural circuitry and alters synaptic structural plasticity are poorly understood. The nogo-66 receptor 1 gene (ngr1 is one candidate that may restrict the rate of learning as well as basal anatomical plasticity in adult cerebral cortex. To investigate if ngr1 limits the rate of learning we tested adult ngr1 null mice on a tactile learning task. Ngr1 mutants display greater overall performance despite a normal rate of improvement on the gap-cross assay, a whisker-dependent learning paradigm. To determine if ngr1 restricts basal anatomical plasticity in the associated sensory cortex, we repeatedly imaged dendritic spines and axonal varicosities of both constitutive and conditional adult ngr1 mutant mice in somatosensory barrel cortex for two weeks through cranial windows with two-photon chronic in vivo imaging. Neither constant nor acute deletion of ngr1 affected turnover or stability of dendritic spines or axonal boutons. The improved performance on the gap-cross task is not attributable to greater motor coordination, as ngr1 mutant mice possess a mild deficit in overall performance and a normal learning rate on the rotarod, a motor task. Mice lacking ngr1 also exhibit normal induction of tone-associated fear conditioning yet accelerated fear extinction and impaired consolidation. Thus, ngr1 alters tactile and motor task performance but does not appear to limit the rate of tactile or motor learning, nor determine the low set point for synaptic turnover in sensory cortex.

  8. Morphometric anatomical and CT study of the human adult sacroiliac region.

    Science.gov (United States)

    Postacchini, Roberto; Trasimeni, Guido; Ripani, Francesca; Sessa, Pasquale; Perotti, Stefano; Postacchini, Franco

    2017-01-01

    To identify and describe the morphometry and CT features of the articular and extra-articular portions of the sacroiliac region. The resulting knowledge might help to avoid complications in sacroiliac joint (SIJ) fusion. We analyzed 102 dry hemi-sacra, 80 ilia, and 10 intact pelves and assessed the pelvic computerized tomography (CT) scans of 90 patients, who underwent the examination for conditions not involving the pelvis. We assessed both the posterior aspect of sacrum with regard to the depressions located externally to the lateral sacral crest at the level of the proximal three sacral vertebrae and the posteroinferior aspect of ilium. Coronal and axial CT scans of the SIJ of patients were obtained and the joint space was measured. On each side, the sacrum exhibits three bone depressions, not described in anatomic textbooks or studies, facing the medial aspect of the posteroinferior ilium, not yet described in detail. Both structures are extra-articular portions situated posteriorly to the SIJ. Coronal CT scans of patients showing the first three sacral foramens and the interval between sacrum and ilium as a continuous space display only the S1 and S3 portions of SIJ, the intermediate portion being extra-articular. The S2 portion is visible on the most anterior coronal scan. Axial scans show articular and extra-articular portions and features improperly described as anatomic variations. Extra-articular portions of the sacroiliac region, not yet described exhaustively, have often been confused with SIJ. Coronal CT scans through the middle part of sacrum, the most used to evaluate degenerative and inflammatory conditions of SIJ, show articular and extra-articular portions of the region.

  9. European display scene

    Science.gov (United States)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  10. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  11. TU-AB-303-02: A Novel Surrogate to Identify Anatomical Changes During Radiotherapy of Head and Neck Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Gros, S; Roeske, J; Surucu, M [Loyola University Medical Center, Maywood, IL (United States)

    2015-06-15

    Purpose: To develop a novel method to monitor external anatomical changes in head and neck cancer patients in order to help guide adaptive radiotherapy decisions. Methods: The method, developed in MATLAB, reveals internal anatomical changes based on variations observed in external anatomy. Weekly kV-CBCT scans from 11 Head and neck patients were retrospectively analyzed. The pre-processing step first corrects each CBCT for artifacts and removes pixels from the immobilization mask to produce an accurate external contour of the patient’s skin. After registering the CBCTs to the initial planning CT, the external contours from each CBCT (CBCTn) are transferred to the first week — reference — CBCT{sub 1}. Contour radii, defined as the distances between an external contour and the central pixel of each CBCT slice, are calculated for each scan at angular increments of 1 degree. The changes in external anatomy are then quantified by the difference in radial distance between the external contours of CBCT1 and CBCTn. The radial difference is finally displayed on a 2D intensity map (angle vs radial distance difference) in order to highlight regions of interests with significant changes. Results: The 2D radial difference maps provided qualitative and quantitative information, such as the location and the magnitude of external contour divergences and the rate at which these deviations occur. With this method, anatomical changes due to tumor volume shrinkage and patient weight loss were clearly identified and could be correlated with the under-dosage of targets or over-dosage of OARs. Conclusion: This novel method provides an efficient tool to visualize 3D external anatomical modification on a single 2D map. It quickly pinpoints the location of differences in anatomy during the course of radiotherapy, which can help determine if a treatment plan needs to be adapted.

  12. Displays in scintigraphy

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.E.; Pizer, S.M.

    1977-01-01

    Displays have several functions: to transmit images, to permit interaction, to quantitate features and to provide records. The main characteristics of displays used for image transmission are their resolution, dynamic range, signal-to-noise ratio and uniformity. Considerations of visual acuity suggest that the display element size should be much less than the data element size, and in current practice at least 256X256 for a gamma camera image. The dynamic range for image transmission should be such that at least 64 levels of grey (or equivalent) are displayed. Scanner displays are also considered, and in particular, the requirements of a whole-body camera are examined. A number of display systems and devices are presented including a 'new' heated object colour display system. Interaction with displays is considered, including background subtraction, contrast enhancement, position indication and region-of-interest generation. Such systems lead to methods of quantitation, which imply knowledge of the expected distributions. Methods for intercomparing displays are considered. Polaroid displays, which have for so long dominated the field, are in the process of being replaced by stored image displays, now that large cheap memories exist which give an equivalent image quality. The impact of this in nuclear medicine is yet to be seen, but a major effect will be to enable true quantitation. (author)

  13. Early Results of Anatomic Double Bundle Anterior Cruciate Ligament Reconstruction

    OpenAIRE

    Demet Pepele

    2014-01-01

    Aim: The goal in anterior cruciate ligament reconstruction (ACLR) is to restore the normal anatomic structure and function of the knee. In the significant proportion of patients after the traditional single-bundle ACLR, complaints of instability still continue. Anatomic double bundle ACLR may provide normal kinematics in knees, much closer to the natural anatomy. The aim of this study is to clinically assess the early outcomes of our anatomical double bundle ACLR. Material and Method: In our ...

  14. SureTrak Probability of Impact Display

    Science.gov (United States)

    Elliott, John

    2012-01-01

    The SureTrak Probability of Impact Display software was developed for use during rocket launch operations. The software displays probability of impact information for each ship near the hazardous area during the time immediately preceding the launch of an unguided vehicle. Wallops range safety officers need to be sure that the risk to humans is below a certain threshold during each use of the Wallops Flight Facility Launch Range. Under the variable conditions that can exist at launch time, the decision to launch must be made in a timely manner to ensure a successful mission while not exceeding those risk criteria. Range safety officers need a tool that can give them the needed probability of impact information quickly, and in a format that is clearly understandable. This application is meant to fill that need. The software is a reuse of part of software developed for an earlier project: Ship Surveillance Software System (S4). The S4 project was written in C++ using Microsoft Visual Studio 6. The data structures and dialog templates from it were copied into a new application that calls the implementation of the algorithms from S4 and displays the results as needed. In the S4 software, the list of ships in the area was received from one local radar interface and from operators who entered the ship information manually. The SureTrak Probability of Impact Display application receives ship data from two local radars as well as the SureTrak system, eliminating the need for manual data entry.

  15. Anatomical planes: are we teaching accurate surface anatomy?

    Science.gov (United States)

    Mirjalili, S Ali; McFadden, Sarah L; Buckenham, Tim; Wilson, Ben; Stringer, Mark D

    2012-10-01

    Anatomical planes used in clinical practice and teaching anatomy are largely derived from cadaver studies. Numerous inconsistencies in clinically important surface markings exist between and within anatomical reference texts. The aim of this study was to reassess the accuracy of common anatomical planes in vivo using computed tomographic (CT) imaging. CT scans of the trunk in supine adults at end tidal inspiration were analyzed by dual consensus reporting to determine the anatomy of five anatomical planes: sternal angle, transpyloric, subcostal, supracristal, and the plane of the pubic crest. Patients with kyphosis, scoliosis, or abnormal lordosis, distorting space-occupying lesions, or visceromegaly were excluded. Among 153 thoracic CT scans (mean age 63 years, 53% female), the sternal angle was most common at T4 (females) or T4/5 (males) vertebral level, and the tracheal bifurcation, aortic arch, and pulmonary trunk were most often below this plane. In 108 abdominal CT scans (mean age 60 years, 59% female), the subcostal and supracristal planes were most often at L2 (58%) and L4 (69%), respectively. In 52 thoracoabdominal CT scans (mean age 61 years, 56% female), the transpyloric plane was between lower L1 and upper L2 (75%); in this plane were the superior mesenteric artery (56%), formation of the portal vein (53%), tip of the ninth rib (60%), and the left renal hilum (54%), but the right renal hilum and gallbladder fundus were more often below. The surface anatomy of anatomical planes needs revising in the light of results from living subjects using modern imaging techniques. Copyright © 2012 Wiley Periodicals, Inc.

  16. Integrated color face graphs for plant accident display

    International Nuclear Information System (INIS)

    Hara, Fumio

    1987-01-01

    This paper presents an integrated man-machine interface that uses cartoon-like colored graphs in the form of faces, that, through different facial expressions, display a plant condition. This is done by drawing the face on a CRT by nonlinearly transforming 31 variables and coloring the face. This integrated color graphics technique is applied to display the progess of events in the Three Mile Island nuclear power plant accident. Human visual perceptive characteristics are investigated in relation to the perception of the plant accident process, the naturality in face color change, and the consistency between facial expressions and colors. This paper concludes that colors used in an integrated color face graphs must be completely consistent with emotional feelings perceived from the colors. (author)

  17. Monocular display unit for 3D display with correct depth perception

    Science.gov (United States)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  18. Construction of a 3-D anatomical model for teaching temporal lobectomy.

    Science.gov (United States)

    de Ribaupierre, Sandrine; Wilson, Timothy D

    2012-06-01

    Although we live and work in 3 dimensional space, most of the anatomical teaching during medical school is done on 2-D (books, TV and computer screens, etc). 3-D spatial abilities are essential for a surgeon but teaching spatial skills in a non-threatening and safe educational environment is a much more difficult pedagogical task. Currently, initial anatomical knowledge formation or specific surgical anatomy techniques, are taught either in the OR itself, or in cadaveric labs; which means that the trainee has only limited exposure. 3-D computer models incorporated into virtual learning environments may provide an intermediate and key step in a blended learning approach for spatially challenging anatomical knowledge formation. Specific anatomical structures and their spatial orientation can be further clinically contextualized through demonstrations of surgical procedures in the 3-D digital environments. Recordings of digital models enable learner reviews, taking as much time as they want, stopping the demonstration, and/or exploring the model to understand the anatomical relation of each structure. We present here how a temporal lobectomy virtual model has been developed to aid residents and fellows conceptualization of the anatomical relationships between different cerebral structures during that procedure. We suggest in comparison to cadaveric dissection, such virtual models represent a cost effective pedagogical methodology providing excellent support for anatomical learning and surgical technique training. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. The Anatomical Institute at the University of Greifswald during National Socialism: The procurement of bodies and their use for anatomical purposes.

    Science.gov (United States)

    Alvermann, Dirk; Mittenzwei, Jan

    2016-05-01

    This is the first comprehensive account of body procurement at the Anatomical Institute at Greifswald University during National Socialism (NS). As in all other German anatomical departments, the bodies received during this period included increasing numbers of victims of the NS regime. Prior to 1939, 90% of all bodies came from hospitals, state nursing homes and mental institutions (Heil- und Pflegeanstalten), but dropped to less than 30% after 1941. While the total catchment area for body procurement decreased, the number of suppliers increased and included prisons, POW camps, Gestapo offices and military jurisdiction authorities. Among the 432 documented bodies delivered to the institute, 132 came from state nursing homes and mental institutions, mainly from Ueckermünde. These were bodies of persons, who probably were victims of "euthanasia" crimes. The Anatomical Institute also procured 46 bodies of forced laborers, of whom at least twelve had been executed. Other groups of victims included 21 bodies of executed Wehrmacht soldiers and 16 Russian prisoners of war from the camp Stalag II C in Greifswald, who had died of starvation and exhaustion. From 1941 onwards, the number of bodies delivered from prisons and penitentiaries greatly increased. In total, 60 bodies of prisoners, mainly from the penitentiary in Gollnow, were delivered to the Anatomical Institute. Greifswald Anatomical Institute was not just a passive recipient of bodies from all of these sources, but the anatomists actively lobbied with the authorities for an increased body supply for teaching and research purposes. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. SINGLE CHAIN VARIABLE FRAGMENTS OF ANTIBODIES AGAINST DIPHTHERIA TOXIN B-SUBUNIT ISOLATED FROM PHAGE DISPLAY HUMAN ANTIBODY LIBRARY

    Directory of Open Access Journals (Sweden)

    Oliinyk O. S.

    2014-02-01

    Full Text Available Diphtheria toxin is an exoantigen of Corynebacterium diphtheriae that inhibits protein synthesis and kills sensitive cells. The aim of this study was to obtain human recombinant single-chain variable fragment (scFv antibodies against receptor-binding B subunit of diphtheria toxin. 12 specific clones were selected after three rounds of a phage display naїve (unimmunized human antibody library against recombinant B-subunit. scFv DNA inserts from these 12 clones were digested with MvaI, and 6 unique restriction patterns were found. Single-chain antibodies were expressed in Escherichia coli XL1-blue. The recombinant proteins were characterized by immunoblotting of bacterial extracts and detection with an anti-E-tag antibody. The toxin B-subunit-binding function of the single-chain antibody was shown by ELISA. The affinity constants for different clones were found to be from 106 to 108 М–1. Due to the fact, that these antibody fragments recognized epitopes in the receptor-binding Bsubunit of diphtheria toxin, further studies are interesting to evaluate their toxin neutralization properties and potential for therapeutic applications. Obtained scFv-antibodies can also be used for detection and investigation of biological properties of diphtheria toxin.

  1. Advances in phage display technology for drug discovery.

    Science.gov (United States)

    Omidfar, Kobra; Daneshpour, Maryam

    2015-06-01

    Over the past decade, several library-based methods have been developed to discover ligands with strong binding affinities for their targets. These methods mimic the natural evolution for screening and identifying ligand-target interactions with specific functional properties. Phage display technology is a well-established method that has been applied to many technological challenges including novel drug discovery. This review describes the recent advances in the use of phage display technology for discovering novel bioactive compounds. Furthermore, it discusses the application of this technology to produce proteins and peptides as well as minimize the use of antibodies, such as antigen-binding fragment, single-chain fragment variable or single-domain antibody fragments like VHHs. Advances in screening, manufacturing and humanization technologies demonstrate that phage display derived products can play a significant role in the diagnosis and treatment of disease. The effects of this technology are inevitable in the development pipeline for bringing therapeutics into the market, and this number is expected to rise significantly in the future as new advances continue to take place in display methods. Furthermore, a widespread application of this methodology is predicted in different medical technological areas, including biosensing, monitoring, molecular imaging, gene therapy, vaccine development and nanotechnology.

  2. Lacrimal Gland Pathologies from an Anatomical Perspective

    Directory of Open Access Journals (Sweden)

    Mahmut Sinan Abit

    2015-06-01

    Full Text Available Most of the patients in our daily practice have one or more ocular surface disorders including conjucntivitis, keratitis, dry eye disease, meibomian gland dysfunction, contact lens related symptoms, refractive errors,computer vision syndrome. Lacrimal gland has an important role in all above mentioned pathologies due to its major secretory product. An anatomical and physiological knowledge about lacrimal gland is a must in understanding basic and common ophthalmological cases. İn this paper it is aimed to explain the lacrimal gland diseases from an anatomical perspective.

  3. The Science and Politics of Naming: Reforming Anatomical Nomenclature, ca. 1886-1955.

    Science.gov (United States)

    Buklijas, Tatjana

    2017-04-01

    Anatomical nomenclature is medicine's official language. Early in their medical studies, students are expected to memorize not only the bodily geography but also the names for all the structures that, by consensus, constitute the anatomical body. The making and uses of visual maps of the body have received considerable historiographical attention, yet the history of production, communication, and reception of anatomical names-a history as long as the history of anatomy itself-has been studied far less. My essay examines the reforms of anatomical naming between the first modern nomenclature, the 1895 Basel Nomina Anatomica (BNA), and the 1955 Nomina Anatomica Parisiensia (NAP, also known as PNA), which is the basis for current anatomical terminology. I focus on the controversial and ultimately failed attempt to reform anatomical nomenclature, known as Jena Nomina Anatomica (INA), of 1935. Discussions around nomenclature reveal not only how anatomical names are made and communicated, but also the relationship of anatomy with the clinic; disciplinary controversies within anatomy; national traditions in science; and the interplay between international and scientific disciplinary politics. I show how the current anatomical nomenclature, a successor to the NAP, is an outcome of both political and disciplinary tensions that reached their peak before 1945. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Anatomical aspects of the gastrocnemius muscles: A study in 47 fresh cadavers.

    Science.gov (United States)

    Andjelkov, Katarina; Atanasijevic, Tatjana C; Popovic, Vesna M; Sforza, Marcos; Atkinson, Connor J; Soldatovic, Ivan

    2016-08-01

    This study offers objective dimensions of the gastrocnemius muscle and analyzes correlations between dimensional variables, with a view to providing guidance on the proportions of a healthy gastrocnemius muscle for both genders. This anatomical study was conducted at the Institute of Forensic Medicine Faculty of Medicine University of Belgrade, Serbia, from May until November 2014. We included 47 fresh cadavers (up to 12-h postmortem interval) both male and female. The inclusion criteria were absence of any trauma or degenerative findings in lower limbs, normally weighed, and age between 18 and 60 years. The exclusion criteria were significant difference in dimensions between legs and overweighed cadavers. After statistical analysis of gathered data, we were able to define the exact shape and average measures of the medial and lateral head of gastrocnemius muscle in male and female. Factors affecting muscle dimensions are also defined in this study. The method of dissection that we applied could be recommended for exploration of different anatomical structures of calf region. The reported dimensions and correlations are useful guide in planning cosmetic and reconstructive procedures with high accuracy. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Deformable meshes for medical image segmentation accurate automatic segmentation of anatomical structures

    CERN Document Server

    Kainmueller, Dagmar

    2014-01-01

    ? Segmentation of anatomical structures in medical image data is an essential task in clinical practice. Dagmar Kainmueller introduces methods for accurate fully automatic segmentation of anatomical structures in 3D medical image data. The author's core methodological contribution is a novel deformation model that overcomes limitations of state-of-the-art Deformable Surface approaches, hence allowing for accurate segmentation of tip- and ridge-shaped features of anatomical structures. As for practical contributions, she proposes application-specific segmentation pipelines for a range of anatom

  6. Development of advanced direct perception displays for nuclear power plants to enhance monitoring, control and fault management

    International Nuclear Information System (INIS)

    Jones, B.; Shaheen, S.; Moray, N.; Sanderson, P.; Reising, D.V.

    1993-01-01

    With recent theoretical and empirical research in basic and applied psychology, human factors, and engineering, it is now sufficient to define an integrated approach to the deign of advanced displays for present and future nuclear power plants. Traditionally, the conventional displays have shown operators the individual variables on gauges, meters, strip charts, etc. This design approach requires the operators to mentally integrate the separately displayed variables and determine the implications for the plant state. This traditional approach has been known as the single-sensor-single-indicator display design and it places an intolerable amount of mental workload on operators during transients and abnormal conditions. This report discusses a new alternative approach which is the use of direct perception interfaces. Direct perception a interfaces display the underlying physical and system constraints of the situation in a directly perceptual way, such that the viewer need not reason about what is seen to identify system states, but can identify the state of the system perceptually. It is expected that displays which show the dynamics of fundamental physical laws should better support operator decisions and diagnoses of plant states. The purpose of this research project is to develop a suite of direct perception displays for PWR nuclear power plant operations

  7. 16 CFR Figure 1 to Part 1203 - Anatomical Planes

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Anatomical Planes 1 Figure 1 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 1 Figure 1 to Part 1203—Anatomical Planes ER10MR98.001 ...

  8. Alpha-contingent EEG feedback reduces SPECT rCBF variability

    DEFF Research Database (Denmark)

    McLaughlin, Thomas; Steinberg, Bruce; Mulholland, Thomas

    2005-01-01

    EEG feedback methods, which link the occurrence of alpha to the presentation of repeated visual stimuli, reduce the relative variability of subsequent, alpha-blocking event durations. The temporal association between electro-cortical field activation and regional cerebral blood flow (rCBF) led us...... to investigate whether the reduced variability of alpha-blocking durations with feedback is associated with a reduction in rCBF variability. Reduced variability in the rCBF response domain under EEG feedback control might have methodological implications for future brain-imaging studies. Visual stimuli were...... to quantify the variance-reducing effects of ACS across multiple, distributed areas of the brain. Both EEG and rCBF measures demonstrated decreased variability under ACS. This improved control was seen for localized as well as anatomically distributed rCBF measures....

  9. The Fate of Anatomical Collections

    NARCIS (Netherlands)

    Knoeff, Rina; Zwijnenberg, Robert

    Almost every medical faculty possesses anatomical and/or pathological collections: human and animal preparations, wax- and other models, as well as drawings, photographs, documents and archives relating to them. In many institutions these collections are well-preserved, but in others they are poorly

  10. Anatomical success in patients after retinectomy for complex retinal detachment

    International Nuclear Information System (INIS)

    Mukhtar, A.; Ishaq, M.; Islam, Q.U.

    2015-01-01

    To evaluate the efficacy of primary and redo retinectomy in eyes with complex retinal detachment. Study Design: Quasi-experimental study. Place and Duration of Study: Armed Forces Institute of Ophthalmology Rawalpindi from Jan 2012 to June 2013. Patients and Methods: Fifty eight eyes (patients) underwent relaxing retinectomies for complex retinal detachment with proliferative vitreoretinopathy or intrinsic retinal shortening. Operative technique included pars plana vitrectomy, proliferative vitreoretinopathy management, use of intraoperative perfluorocarbon liquid, retinectomy, endolaser and intraocular temponade. The main outcome was anatomic success, defined as complete retinal reattachment at four months follow up. Eighteen eyes out of the same primary group underwent second retinectomy because of anatomical failure. Results: Mean age of study population was 53.78 ± 15.11 years, 56.9% of patients were male(s). Anatomic success rate after 1st retinectomy was achieved in 68.96% (40 eyes out of 58). In eighteen eyes that underwent 2nd retinectomy, anatomic success rate was 72.22% (13 eyes out of 18). Overall success rate was 91.3% (53 eyes out of 58) in our study. Conclusions: Relaxing retinectomies for retinal shortening can improve the anatomical success rate in patients with complex RD. (author)

  11. Evaluation of anatomical and physical properties of Khaya nthotheca

    African Journals Online (AJOL)

    The anatomical and physical properties of Khaya anthotheca (Welw.) C. DC wood from the transition forest of middle altitude (zone 1) and the humid dense forest of low altitude (zone 2) in the East of the Democratic Republic of Congo were evaluated to ascertain the effect of growth area on the anatomical and physical ...

  12. Laryngeal spaces and lymphatics: current anatomic concepts

    International Nuclear Information System (INIS)

    Welsh, L.W.; Welsh, J.J.; Rizzo, T.A. Jr.

    1983-01-01

    This investigation evaluates the anatomic concepts of individual spaces or compartments within the larynx by isotope and dye diffusion. The authors identified continuity of spaces particularly within the submucosal planes and a relative isolation within the fixed structures resulting from the longitudinal pattern of fibroelastic tissues, muscle bands, and perichondrium. The historical data of anatomic resistance are refuted by the radioisotope patterns of dispersion and the histologic evidence of tissue permeability to the carbon particles. There is little clinical application of the compartment concept to the perimeter of growth and the configuration of extensive endolaryngeal cancers. The internal and extralaryngeal lymphatic network is presented and the regional associations are identified. The normal ipsilateral relationship is distorted by dispersion within the endolarynx supervening the anatomic midline. The effects of lymphatic obstruction caused by regional lymphadenectomy, tumor fixation, and irradiation-infection sequelae are illustrated; these result in widespread bilateral lymphatic nodal terminals. Finally, the evidence suggests that the internal network is modified by external interruption to accommodate an outflow system in continuity with the residual patent lymphatic channels

  13. [Lymphoscintigrams with anatomical landmarks obtained with vector graphics].

    Science.gov (United States)

    Rubini, Giuseppe; Antonica, Filippo; Renna, Maria Antonia; Ferrari, Cristina; Iuele, Francesca; Stabile Ianora, Antonio Amato; Losco, Matteo; Niccoli Asabella, Artor

    2012-11-01

    Nuclear medicine images are difficult to interpret because they do not include anatomical details. The aim of this study was to obtain lymphoscintigrams with anatomical landmarks that could be easily interpreted by General Physicians. Traditional lymphoscintigrams were processed with Adobe© Photoshop® CS6 and converted into vector images created by Illustrator®. The combination with a silhouette vector improved image interpretation, without resulting in longer radiation exposure or acquisition times.

  14. The Intermingled History of Occupational Therapy and Anatomical Education: A Retrospective Exploration

    Science.gov (United States)

    Carroll, Melissa A.; Lawson, Katherine

    2014-01-01

    Few research articles have addressed the anatomical needs of entry-level occupational therapy students. Given this paucity of empirical evidence, there is a lack of knowledge regarding anatomical education in occupational therapy. This article will primarily serve as a retrospective look at the inclusion of anatomical education in the occupational…

  15. A Reinforcement-Based Learning Paradigm Increases Anatomical Learning and Retention—A Neuroeducation Study

    Science.gov (United States)

    Anderson, Sarah J.; Hecker, Kent G.; Krigolson, Olave E.; Jamniczky, Heather A.

    2018-01-01

    In anatomy education, a key hurdle to engaging in higher-level discussion in the classroom is recognizing and understanding the extensive terminology used to identify and describe anatomical structures. Given the time-limited classroom environment, seeking methods to impart this foundational knowledge to students in an efficient manner is essential. Just-in-Time Teaching (JiTT) methods incorporate pre-class exercises (typically online) meant to establish foundational knowledge in novice learners so subsequent instructor-led sessions can focus on deeper, more complex concepts. Determining how best do we design and assess pre-class exercises requires a detailed examination of learning and retention in an applied educational context. Here we used electroencephalography (EEG) as a quantitative dependent variable to track learning and examine the efficacy of JiTT activities to teach anatomy. Specifically, we examined changes in the amplitude of the N250 and reward positivity event-related brain potential (ERP) components alongside behavioral performance as novice students participated in a series of computerized reinforcement-based learning modules to teach neuroanatomical structures. We found that as students learned to identify anatomical structures, the amplitude of the N250 increased and reward positivity amplitude decreased in response to positive feedback. Both on a retention and transfer exercise when learners successfully remembered and translated their knowledge to novel images, the amplitude of the reward positivity remained decreased compared to early learning. Our findings suggest ERPs can be used as a tool to track learning, retention, and transfer of knowledge and that employing the reinforcement learning paradigm is an effective educational approach for developing anatomical expertise. PMID:29467638

  16. A Reinforcement-Based Learning Paradigm Increases Anatomical Learning and Retention—A Neuroeducation Study

    Directory of Open Access Journals (Sweden)

    Sarah J. Anderson

    2018-02-01

    Full Text Available In anatomy education, a key hurdle to engaging in higher-level discussion in the classroom is recognizing and understanding the extensive terminology used to identify and describe anatomical structures. Given the time-limited classroom environment, seeking methods to impart this foundational knowledge to students in an efficient manner is essential. Just-in-Time Teaching (JiTT methods incorporate pre-class exercises (typically online meant to establish foundational knowledge in novice learners so subsequent instructor-led sessions can focus on deeper, more complex concepts. Determining how best do we design and assess pre-class exercises requires a detailed examination of learning and retention in an applied educational context. Here we used electroencephalography (EEG as a quantitative dependent variable to track learning and examine the efficacy of JiTT activities to teach anatomy. Specifically, we examined changes in the amplitude of the N250 and reward positivity event-related brain potential (ERP components alongside behavioral performance as novice students participated in a series of computerized reinforcement-based learning modules to teach neuroanatomical structures. We found that as students learned to identify anatomical structures, the amplitude of the N250 increased and reward positivity amplitude decreased in response to positive feedback. Both on a retention and transfer exercise when learners successfully remembered and translated their knowledge to novel images, the amplitude of the reward positivity remained decreased compared to early learning. Our findings suggest ERPs can be used as a tool to track learning, retention, and transfer of knowledge and that employing the reinforcement learning paradigm is an effective educational approach for developing anatomical expertise.

  17. Resolving structural variability in network models and the brain.

    Directory of Open Access Journals (Sweden)

    Florian Klimm

    2014-03-01

    Full Text Available Large-scale white matter pathways crisscrossing the cortex create a complex pattern of connectivity that underlies human cognitive function. Generative mechanisms for this architecture have been difficult to identify in part because little is known in general about mechanistic drivers of structured networks. Here we contrast network properties derived from diffusion spectrum imaging data of the human brain with 13 synthetic network models chosen to probe the roles of physical network embedding and temporal network growth. We characterize both the empirical and synthetic networks using familiar graph metrics, but presented here in a more complete statistical form, as scatter plots and distributions, to reveal the full range of variability of each measure across scales in the network. We focus specifically on the degree distribution, degree assortativity, hierarchy, topological Rentian scaling, and topological fractal scaling--in addition to several summary statistics, including the mean clustering coefficient, the shortest path-length, and the network diameter. The models are investigated in a progressive, branching sequence, aimed at capturing different elements thought to be important in the brain, and range from simple random and regular networks, to models that incorporate specific growth rules and constraints. We find that synthetic models that constrain the network nodes to be physically embedded in anatomical brain regions tend to produce distributions that are most similar to the corresponding measurements for the brain. We also find that network models hardcoded to display one network property (e.g., assortativity do not in general simultaneously display a second (e.g., hierarchy. This relative independence of network properties suggests that multiple neurobiological mechanisms might be at play in the development of human brain network architecture. Together, the network models that we develop and employ provide a potentially useful

  18. An anatomical study of the transversus nuchae muscle: Application to better understanding occipital neuralgia.

    Science.gov (United States)

    Watanabe, Koichi; Saga, Tsuyoshi; Iwanaga, Joe; Tabira, Yoko; Yamaki, Koh-Ichi

    2017-01-01

    The transversus nuchae muscle appears inconsistently in the occipital region. It has gained attention as one of the muscles composing the superficial musculoaponeurotic system (SMAS). The purpose of this study was to clarify its detailed anatomical features. We examined 124 sides of 62 cadavers. The transversus nuchae muscle was identified when present and examined after it had been completely exposed. We also examined its relationship to the occipital cutaneous nerves.The transversus nuchae muscle was detected in 40 sides (40/124, 32.2%) of 26 cadavers; it was present bilaterally in 14 and unilaterally in 12. It originated from the external occipital protuberance; 43% of the observed muscles inserted around the mastoid process, and 58% curved upward around the mastoid process and became the uppermost bundle of the platysma. In one case, an additional bundle originated from the lower posterior border of the sternocleidomastoid muscle and coursed obliquely upward along with platysma. Ninety percent of the muscles ran below the sling through which the greater occipital nerve passed; 65% of the lesser occipital nerves ran deep to the muscle, and 55% of the great auricular nerves ran superficial to it. Our observations clarify the unique anatomical features of the transversus nuchae muscle. We found that it occurs at a rate similar to that described in previous reports, but its arrangement is variable. Further investigations will be performed to clarify its innervation and other anatomical features. Clin. Anat. 30:32-38, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Invisible Display in Aluminum

    DEFF Research Database (Denmark)

    Prichystal, Jan Phuklin; Hansen, Hans Nørgaard; Bladt, Henrik Henriksen

    2005-01-01

    Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish for an integ......Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish...... for an integrated display in a metal surface is often ruled by design and functionality of a product. The integration of displays in metal surfaces requires metal removal in order to clear the area of the display to some extent. The idea behind an invisible display in Aluminum concerns the processing of a metal...

  20. Abnormal anatomical connectivity between the amygdala and orbitofrontal cortex in conduct disorder.

    Directory of Open Access Journals (Sweden)

    Luca Passamonti

    Full Text Available Previous research suggested that structural and functional abnormalities within the amygdala and orbitofrontal cortex contribute to the pathophysiology of Conduct Disorder (CD. Here, we investigated whether the integrity of the white-matter pathways connecting these regions is abnormal and thus may represent a putative neurobiological marker for CD.Diffusion Tensor Imaging (DTI was used to investigate white-matter microstructural integrity in male adolescents with childhood-onset CD, compared with healthy controls matched in age, sex, intelligence, and socioeconomic status. Two approaches were employed to analyze DTI data: voxel-based morphometry of fractional anisotropy (FA, an index of white-matter integrity, and virtual dissection of white-matter pathways using tractography.Adolescents with CD displayed higher FA within the right external capsule relative to controls (T = 6.08, P<0.05, Family-Wise Error, whole-brain correction. Tractography analyses showed that FA values within the uncinate fascicle (connecting the amygdala and orbitofrontal cortex were abnormally increased in individuals with CD relative to controls. This was in contrast with the inferior frontal-occipital fascicle, which showed no significant group differences in FA. The finding of increased FA in the uncinate fascicle remained significant when factoring out the contribution of attention-deficit/hyperactivity disorder symptoms. There were no group differences in the number of streamlines in either of these anatomical tracts.These results provide evidence that CD is associated with white-matter microstructural abnormalities in the anatomical tract that connects the amygdala and orbitofrontal cortex, the uncinate fascicle. These results implicate abnormal maturation of white-matter pathways which are fundamental in the regulation of emotional behavior in CD.

  1. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  2. Image-anatomic research of the alar ligament

    International Nuclear Information System (INIS)

    Hao Caixian; Liu Jun; Jin Ying; Wang Jian; Zhong Jin; Wang Jinyue; Zhu Miao; Cheng Jinbao

    2008-01-01

    Objective: To detect position and morphous as well as coursing of the alar ligament, and to further investigate the sectional anatomy and CT and MRI imaging of the alar ligament. Methods: Twelve formalin fixed specimens including head and neck utilized, three of the twelve were observed in gross anatomy, nine of them were dissectioned. Fifty- one healthy volunteers from each group were selected to perform CT and MRI examination respectively. By combining gross and sectional anatomy. CT and MRI manifestations of the alar ligament were analyzed, the alar ligament width was measured. Results: Location and shape, as well as coursing of the alar ligament could be demonstrated clearly in gross and sectional anatomy. The transverse plane across the upper dens and the coronal plane by the middle dens were the optimal planes for demonstrating the alar ligament. The display ratio of the alar ligament was even 100% (51/51) in both images of CT and MRI. MRI had better advantages than CT in respect of demonstrating the alar ligament, PDWI (proton density weighted imaging, PDWI) is the most optimal sequence for the alar ligament. There were no significant differences of the alar ligament width between male and female and between the right and the left side (P>0.05). Conclusion: In combination with gross and sectional anatomy. CT and MRI could both provide an imageo-anatomic basis for diagnosis of the alar ligament trauma and malformation as well as infection. (authors)

  3. Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method

    Science.gov (United States)

    Baikejiang, Reheman; Zhao, Yue; Fite, Brett Z.; Ferrara, Katherine W.; Li, Changqing

    2017-01-01

    Abstract. Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well known that FMT image quality can be improved substantially by applying the structural guidance in the FMT reconstruction. An approach to introducing anatomical information into the FMT reconstruction is presented using the kernel method. In contrast to conventional methods that incorporate anatomical information with a Laplacian-type regularization matrix, the proposed method introduces the anatomical guidance into the projection model of FMT. The primary advantage of the proposed method is that it does not require segmentation of targets in the anatomical images. Numerical simulations and phantom experiments have been performed to demonstrate the proposed approach’s feasibility. Numerical simulation results indicate that the proposed kernel method can separate two FMT targets with an edge-to-edge distance of 1 mm and is robust to false-positive guidance and inhomogeneity in the anatomical image. For the phantom experiments with two FMT targets, the kernel method has reconstructed both targets successfully, which further validates the proposed kernel method. PMID:28464120

  4. Advanced Colorimetry of Display Systems: Tetra-Chroma3 Display Unit

    Directory of Open Access Journals (Sweden)

    J. Kaiser

    2005-06-01

    Full Text Available High-fidelity color image reproduction is one of the key issues invisual telecommunication systems, for electronic commerce,telemedicine, digital museum and so on. All colorimetric standards ofdisplay systems are up to the present day trichromatic. But, from theshape of a horseshoe-area of all existing colors in the CIE xychromaticity diagram it follows that with three real reproductivelights, the stated area in the CIE xy chromaticity diagram cannot beoverlaid. The expansion of the color gamut of a display device ispossible in a few ways. In this paper, the way of increasing the numberof primaries is studied. The fourth cyan primary is added to threeconventional ones to enlarge the color gamut of reproduction towardscyans and yellow-oranges. The original method of color management forthis new display unit is introduced. In addition, the color gamut ofthe designed additive-based display is successfully compared with thecolor gamut of a modern subtractive-based system. A display with morethan three primary colors is called a multiprimary color display. Thevery advantageous property of such display is the possibility todisplay metameric colors.

  5. Surgical Management of Anatomic Bladder Outlet Obstruction in Males with Neurogenic Bladder Dysfunction: A Systematic Review.

    Science.gov (United States)

    Noordhoff, Toscane C; Groen, Jan; Scheepe, Jeroen R; Blok, Bertil F M

    2018-03-15

    Surgical treatment of anatomic bladder outlet obstruction (BOO) may be indicated in males with neurogenic bladder dysfunction. A bothersome complication after surgery is urinary incontinence. To identify the optimal practice in the surgical treatment of anatomic BOO in males with neurogenic bladder dysfunction, due to multiple sclerosis, Parkinson disease, spinal cord injury (SCI), spina bifida, or cerebrovascular accident (CVA). A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement. Medline, Embase, Cochrane controlled trial databases, Web of Science, and Google Scholar were searched for publications until January 2017. A total of 930 abstracts were screened. Eight studies were included. The types of anatomic BOO discussed were benign prostate obstruction, urethral stricture, and bladder neck sclerosis. The identified surgical treatments were transurethral resection of the prostate (TURP) in patients with Parkinson, CVA or SCI, endoscopic treatment of urethral stricture by laser ablation or urethrotomy (mainly in SCI patients), and bladder neck resection (BNR) in SCI patients. The outcome of TURP may be highly variable, and includes persistent or de novo urinary incontinence, regained normal micturition control, and urinary continence. Good results were seen in BNR and endoscopic urethrotomy studies. Laser ablation and cold knife urethrotomy resulted in restarting intermittent catheterization or adequate voiding. Overall, a high risk of bias was found. This systematic review provides an overview of the current literature on the outcome of several surgical approaches of different types of anatomic BOO in males with neurogenic bladder dysfunction. Identifying the optimal practice was impossible due to limited availability of high-quality studies. The outcome of several surgical approaches in males with neurogenic bladder dysfunction with benign prostate obstruction, urethral stricture

  6. PC Assisted Anatomical Measurements in 3D Using CT Data

    DEFF Research Database (Denmark)

    Hvidtfeldt, Mogens; Pedersen, Steen

    1999-01-01

    To assess facilities and applications of a programme for a PC based CT measurements in 3D of anatomical angelse in the skeleton.......To assess facilities and applications of a programme for a PC based CT measurements in 3D of anatomical angelse in the skeleton....

  7. Anatomical variations of the circle of Willis and cerebrovascular accidents in transitional Albania

    Directory of Open Access Journals (Sweden)

    Edlira Harizi (Shemsi

    2015-12-01

    Full Text Available Aim: The purpose of this study was twofold: i in a case-control design, to determine the relationship between anatomical variations of the circle of Willis and cerebrovascular accidents; ii to assess the association between anatomical variations of the circle of Willis and aneurisms among patients with subarachnoid hemorrhage. Methods: A case-control study was conducted in Albania in 2013-2014, including 100 patients with subarachnoid hemorrhage and 100 controls (individuals without cerebrovascular accidents. Patients with subarachnoid hemorrhage underwent a CT angiography procedure, whereas individuals in the control group underwent a magnetic resonance angiography procedure. Binary logistic regression was used to assess the association between cerebrovascular accidents and the anatomical variations of the circle of Willis. Conversely, Fisher’s exact test was used to compare the prevalence of aneurisms between subarachnoid hemorrhage patients with and without anatomical variations of the circle of Willis. Results: Among patients, there were 22 (22% cases with anatomical variations of the circle of Willis compared with 10 (10% individuals in the control group (P=0.033. There was no evidence of a statistically significant difference in the types of the anatomical variations of the circle of Willis between patients and controls (P=0.402. In age- and-sex adjusted logistic regression models, there was evidence of a significant positive association between cerebrovascular accidents and the anatomical variations of the circle of Willis (OR=1.87, 95%CI=1.03-4.68, P=0.048. Within the patients’ group, of the 52 cases with aneurisms, there were 22 (42.3% individuals with anatomical variations of the circle of Willis compared with no individuals with anatomical variations among the 48 patients without aneurisms (P<0.001. Conclusion: This study provides useful evidence on the association between anatomical variations of the circle of Willis and

  8. [The anatomical revolution and the transition of anatomical conception in late imperial china].

    Science.gov (United States)

    Sihn, Kyu Hwan

    2012-04-30

    This paper aimed to examine the anatomical revolution from Yilingaicuo (Correcting the Errors of Medicine) and Quantixinlun(Outline of Anatomy and Physiology) in late imperial China. As the cephalocentrism which the brain superintend human operation of the mind was diffused in China since 16th century, the cephalocentrism and the cardiocentrism had competed for the hegemony of anatomical conception. Because of the advent of Yilingaicuo and Quantixinlun, the cephalocentrism became the main stream in the anatomical conception. The supporters of the Wang Yangming's Xinxue(the Learning of Heart and Mind) argued that the heart was the central organ of perception, sensitivity, and morality of the human body in medicine since 16th century. Even reformist and revolutionary intellectuals like Tan sitong and Mao zedong who had supported the Wang Yangming's Xinxue embraced the cephalocentrism in the late 19th century and the early 20th century. May Fourth intellectuals had not obsessed metaphysical interpretation of human body any more in the New Culture Movement in 1910s. They regarded human body as the object of research and writing. The anatomy was transformed into the instrumental knowledge for mutilation of the body. Yilingaicuo challenged the traditional conception of body, and Chinese intellectuals drew interest in the anatomy knowledge based on real mutilation. Quantixinlun based on Western medicine fueled a controversy about anatomy. Though new knowledge of anatomy was criticized by traditional Chinese medical doctors from the usefulness and morality of anatomy, nobody disavowed new knowledge of anatomy from the institutionalization of Western medicine in medical school. The internal development of cephalocentrism and positivism had influence on anatomy in China since 16th century. The advent of Yilingaicuo and Quantixinlun provided the milestone of new anatomy, though both sides represented traditional Chinese medicine and Western medicine respectively. They

  9. Microlaser-based displays

    Science.gov (United States)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  10. Patellar calcar: MRI appearance of a previously undescribed anatomical entity

    International Nuclear Information System (INIS)

    Collins, Mark S.; Tiegs-Heiden, Christin A.; Stuart, Michael J.

    2014-01-01

    The femoral calcar is a constant anatomical structure within the proximal femur representing a condensation of bone trabeculae. It is our impression that a similar structure is present within the patella. The purpose of this retrospective study was to define the prevalence, appearance, location, and configuration of the patellar calcar on MRI examinations. One hundred consecutive unenhanced knee MRIs were retrospectively reviewed by two readers who were blinded to the clinical indication. The patellar calcar was defined as a dark signaling, linear or curvilinear structure subjacent to the patellar articular surface. If present, the patellar calcar was assigned to a ''well seen,'' ''moderately well seen,'' or ''faintly seen'' category. Location of the calcar within the patella, orientation, configuration, and thickness were recorded. Confounding variables, such as marrow edema, patellar chondromalacia, bipartite patella, or postoperative changes were also recorded. The patellar calcar was visualized in 81 out of 100 (81 %) MRIs. When detected, the calcar was well seen in 20 out of 81 (25 %), moderately well seen in 35 out of 81 (43 %), and faintly seen in 26 out of 81 (32 %). The anteroposterior width of the calcar measured at its thickest segment was: 1 mm in 10 out of 81 (12 %). The patellar calcar was seen in the majority of knee MRIs and had a consistent imaging appearance. The calcar may be obscured by degenerative arthrosis of the patella and rarely may mimic patellar stress fracture or osteochondritis dissecans. Radiologists and clinicians should be familiar with this normal anatomical structure. (orig.)

  11. Screening for single-chain variable fragment antibodies against multiple Cry1 toxins from an immunized mouse phage display antibody library.

    Science.gov (United States)

    Dong, Sa; Bo, Zongyi; Zhang, Cunzheng; Feng, Jianguo; Liu, Xianjin

    2018-04-01

    Single-chain variable fragment (scFv) is a kind of antibody that possess only one chain of the complete antibody while maintaining the antigen-specific binding abilities and can be expressed in prokaryotic system. In this study, scFvs against Cry1 toxins were screened out from an immunized mouse phage displayed antibody library, which was successfully constructed with capacity of 6.25 × 10 7  CFU/mL. Using the mixed and alternative antigen coating strategy and after four rounds of affinity screening, seven positive phage-scFvs against Cry1 toxins were selected and characterized. Among them, clone scFv-3H9 (MG214869) showing relative stable and high binding abilities to six Cry1 toxins was selected for expression and purification. SDS-PAGE indicated that the scFv-3H9 fragments approximately 27 kDa were successfully expressed in Escherichia coli HB2151 strain. The purified scFv-3H9 was used to establish the double antibody sandwich enzyme-linked immunosorbent assay method (DAS-ELISA) for detecting six Cry1 toxins, of which the lowest detectable limits (LOD) and the lowest quantitative limits (LOQ) were 3.14-11.07 and 8.22-39.44 ng mL -1 , respectively, with the correlation coefficient higher than 0.997. The average recoveries of Cry1 toxins from spiked rice leaf samples were ranged from 84 to 95%, with coefficient of variation (CV) less than 8.2%, showing good accuracy for the multi-residue determination of six Cry1 toxins in agricultural samples. This research suggested that the constructed phage display antibody library based on the animal which was immunized with the mixture of several antigens under the same category can be used for the quick and effective screening of generic antibodies.

  12. Prefrontal-Thalamic Anatomical Connectivity and Executive Cognitive Function in Schizophrenia.

    Science.gov (United States)

    Giraldo-Chica, Monica; Rogers, Baxter P; Damon, Stephen M; Landman, Bennett A; Woodward, Neil D

    2018-03-15

    Executive cognitive functions, including working memory, cognitive flexibility, and inhibition, are impaired in schizophrenia. Executive functions rely on coordinated information processing between the prefrontal cortex (PFC) and thalamus, particularly the mediodorsal nucleus. This raises the possibility that anatomical connectivity between the PFC and mediodorsal thalamus may be 1) reduced in schizophrenia and 2) related to deficits in executive function. The current investigation tested these hypotheses. Forty-five healthy subjects and 62 patients with a schizophrenia spectrum disorder completed a battery of tests of executive function and underwent diffusion-weighted imaging. Probabilistic tractography was used to quantify anatomical connectivity between six cortical regions, including PFC, and the thalamus. Thalamocortical anatomical connectivity was compared between healthy subjects and patients with schizophrenia using region-of-interest and voxelwise approaches, and the association between PFC-thalamic anatomical connectivity and severity of executive function impairment was examined in patients. Anatomical connectivity between the thalamus and PFC was reduced in schizophrenia. Voxelwise analysis localized the reduction to areas of the mediodorsal thalamus connected to lateral PFC. Reduced PFC-thalamic connectivity in schizophrenia correlated with impaired working memory but not cognitive flexibility and inhibition. In contrast to reduced PFC-thalamic connectivity, thalamic connectivity with somatosensory and occipital cortices was increased in schizophrenia. The results are consistent with models implicating disrupted PFC-thalamic connectivity in the pathophysiology of schizophrenia and mechanisms of cognitive impairment. PFC-thalamic anatomical connectivity may be an important target for procognitive interventions. Further work is needed to determine the implications of increased thalamic connectivity with sensory cortex. Copyright © 2017 Society of

  13. A reusable anatomically segmented digital mannequin for public health communication.

    Science.gov (United States)

    Fujieda, Kaori; Okubo, Kosaku

    2016-01-01

    The ongoing development of world wide web technologies has facilitated a change in health communication, which has now become bi-directional and encompasses people with diverse backgrounds. To enable an even greater role for medical illustrations, a data set, BodyParts3D, has been generated and its data set can be used by anyone to create and exchange customised three-dimensional (3D) anatomical images. BP3D comprises more than 3000 3D object files created by segmenting a digital mannequin in accordance with anatomical naming conventions. This paper describes the methodologies and features used to generate an anatomically correct male mannequin.

  14. Handbook of display technology

    CERN Document Server

    Castellano, Joseph A

    1992-01-01

    This book presents a comprehensive review of technical and commercial aspects of display technology. It provides design engineers with the information needed to select proper technology for new products. The book focuses on flat, thin displays such as light-emitting diodes, plasma display panels, and liquid crystal displays, but it also includes material on cathode ray tubes. Displays include a large number of products from televisions, auto dashboards, radios, and household appliances, to gasoline pumps, heart monitors, microwave ovens, and more.For more information on display tech

  15. Leaf anatomy of the South African Danthonieae (Poaceae. III. Merxmuellera stricta

    Directory of Open Access Journals (Sweden)

    R. P. Ellis

    1980-11-01

    Full Text Available The anatomical structure, of the leaf blade as seen in transverse section, and of the abaxial epidermis, of Merxmuellera stricta (Schrad. Conert is described and illustrated. In this variable species four distinct anatomical “forms” are recognized viz. the typical  M. stricta form, the Cathedral Peak form, the Drakensberg form and the alpine form. The alpine and Cathedral Peak forms have recently been described as M. guillarmodiae Conert (1975. The degree of anatomical differentiation of these “forms” resembles the situation described in M. disticha (Nees Conert (Ellis, 1980. Populations of both M. stricta and M. disticha from the Drakensberg mountains display extensive anatomical diversification which appears to be correlated with environmental factors. In addition, morphological differences are exhibited as well and the anatomical “forms” of M. stricta probably warrant taxonomic recognition.

  16. Liquid crystal display

    International Nuclear Information System (INIS)

    Takami, K.

    1981-01-01

    An improved liquid crystal display device is described which can display letters, numerals and other necessary patterns in the night time using a minimized amount of radioactive material. To achieve this a self-luminous light source is placed in a limited region corresponding to a specific display area. (U.K.)

  17. INFORMATION DISPLAY: CONSIDERATIONS FOR DESIGNING COMPUTER-BASED DISPLAY SYSTEMS

    International Nuclear Information System (INIS)

    O'HARA, J.M.; PIRUS, D.; BELTRATCCHI, L.

    2004-01-01

    This paper discussed the presentation of information in computer-based control rooms. Issues associated with the typical displays currently in use are discussed. It is concluded that these displays should be augmented with new displays designed to better meet the information needs of plant personnel and to minimize the need for interface management tasks (the activities personnel have to do to access and organize the information they need). Several approaches to information design are discussed, specifically addressing: (1) monitoring, detection, and situation assessment; (2) routine task performance; and (3) teamwork, crew coordination, collaborative work

  18. Sinonasal anatomical variations: their relationship with chronic rhinosinusitis and effect on the severity of disease-a computerized tomography assisted anatomical and clinical study.

    Science.gov (United States)

    Kaygusuz, Ahmet; Haksever, Mehmet; Akduman, Davut; Aslan, Sündüs; Sayar, Zeynep

    2014-09-01

    The anatomy of the sinonasal area has a very wide rage of anatomical variations. The significance of these anatomical variations in pathogenesis of rhinosinusitis, which is the commonest disease in the region, is still unclear. The aims of the study were to compare the rate of sinonasal anatomical variations with development and severity of chronic rhinosinusitis patients. CT scan of paranasal sinuses images of 99 individuals were retrospectively reviewed. 65 cases of chronic rhinosinusitis (study group) who had undergone endoscopic sinus surgery were compared with 34 cases without chronic rhinosinusitis (control group). Also in study group Lund-Mackay score of the sinus disease were calculated and compared to the rate of related anatomical variations. There were 74 (74.7 %) males and 25 (25.2 %) females with ages ranging from 13 to 70 years (mean 32.2 years). The anatomical variations recorded were: Septal deviation 47 (72.3) in study and 25 (73.5 %) in control group, concha bullosa 27 (41.5 %) in study and 18 (52.9 %) in control group, overpneumatized ethmoid bulla 17 (26.1 %) in study and 14 (41.1 %) in control group, pneumatized uncinate 3 (4.6 %) in study and 3 (8.8 %) in control group, agger nasi 42 (64.6 %) in study and 19 (55.8 %) in control group, paradoxical middle turbinates 9 (13.8 %) in study and 4 (11.7 %) in control group, Onodi cell 6 (9.2 %) in study and 2 (5.8 %) in control group, Haller's cells (infraorbital ethmoid cell) 9 (13.8 %) in study and 7 (20.5 %) in control group. None of these results were statistically significant between study and control group (p > 0.05). Lund-Mackay score (which was assumed to show the severity of the disease) of the maxillary, ethmoid and frontal sinus were calculated and compared to rate of septal deviation, concha bullosa, agger nasi cells. No significant correlation was conducted (p > 0.05). The results of study showed no statistically significant correlation between sinonasal anatomical

  19. ArthroBroström Lateral Ankle Stabilization Technique: An Anatomic Study.

    Science.gov (United States)

    Acevedo, Jorge I; Ortiz, Cristian; Golano, Pau; Nery, Caio

    2015-10-01

    Arthroscopic ankle lateral ligament repair techniques have recently been developed and biomechanically as well as clinically validated. Although there has been 1 anatomic study relating suture and anchor proximity to anatomic structures, none has evaluated the ArthroBroström procedure. To evaluate the proximity of anatomic structures for the ArthroBroström lateral ankle ligament stabilization technique and to define ideal landmarks and "safe zones" for this repair. Descriptive laboratory study. Ten human cadaveric ankle specimens (5 matched pairs) were screened for the study. All specimens underwent arthroscopic lateral ligament repair according to the previously described ArthroBroström technique with 2 suture anchors in the fibula. Three cadaveric specimens were used to test the protocol, and 7 were dissected to determine the proximity of anatomic structures. Several distances were measured, including those of different anatomic structures to the suture knots, to determine the "safe zones." Measurements were obtained by 2 separate observers, and statistical analysis was performed. None of the specimens revealed entrapment by either of the suture knots of the critical anatomic structures, including the superficial peroneal nerve (SPN), sural nerve, peroneus tertius tendon, peroneus brevis tendon, or peroneus longus tendon. The internervous safe zone between the intermediate branch of the SPN and sural nerve was a mean of 51 mm (range, 39-64 mm). The intertendinous safe zone between the peroneus tertius and peroneus brevis was a mean of 43 mm (range, 37-49 mm). On average, a 20-mm (range, 8-36 mm) safe distance was maintained from the most medial suture to the intermediate branch of the SPN. The amount of inferior extensor retinaculum (IER) grasped by either suture knot varied from 0 to 12 mm, with 86% of repairs including the retinaculum. The results indicate that there is a relatively wide internervous and intertendinous safe zone when performing the Arthro

  20. ROOT ANATOMICAL PLASTICITY IN RESPONSE TO SALT STRESS UNDER REAL AND FULL-SEASON FIELD CONDITIONS AND DETERMINATION OF NEW ANATOMIC SELECTION CHARACTERS FOR BREEDING SALT-RESISTANT RICE (Oryza sativa L.

    Directory of Open Access Journals (Sweden)

    Mehmet AYBEKE

    2016-12-01

    Full Text Available Specific understanding of root anatomy plasticity under salt stress is lacking and requires creation of efficient screening techniques for stress condition s. To fill this gap, this study aimed to determine the anatomical plasticity in root chracteristics of 31 different rice cultivars (from ‘Best’ to ‘Low’ yielding grown under real field conditions (saline and non-saline from planting to harvesting and to reveal detailed root anatomical parameters that can be used to select and breed salt-tolerant rice. Anatomical and histochemical features of all cultivars and thin structures of the apoplastic barriers were investigated. The amount of silica (Si, 35 different anatomical characteristics, anatomical plasticity characteristics, plasticity rates, plasticity trends and changes and strategies of each group under saline and non-saline conditions were compared. The results showed that protective anatomical characters improved/remained equal to, and worsened/remained equal to those of the controls, in the ‘Best’ and other groups, respectively, from non-saline to saline conditions. Anatomical plasticity is essentially directly related to apoplastic barrier features. High genotypic variation was observed in root anatomy in all cultivars, but foremost traits were as follows: (1 cell size, (2 Si presence, (3 Si accumulation shape, (4 Si distribution towards root stele, (5 xylem arch features, (6 lignification-suberization properties in apoplastic barriers and their degrees, (7 presence/absence of idioblast cells filled with gummic and phenolic substances and (8 moderate anatomical plasticity. Cultivars with the most stabile anatomy under saline and non-saline conditions should be used to select and breed salt-resistant rice.

  1. Anatomic variation of cranial parasympathetic ganglia

    Directory of Open Access Journals (Sweden)

    Selma Siéssere

    2008-06-01

    Full Text Available Having broad knowledge of anatomy is essential for practicing dentistry. Certain anatomical structures call for detailed studies due to their anatomical and functional importance. Nevertheless, some structures are difficult to visualize and identify due to their small volume and complicated access. Such is the case of the parasympathetic ganglia located in the cranial part of the autonomic nervous system, which include: the ciliary ganglion (located deeply in the orbit, laterally to the optic nerve, the pterygopalatine ganglion (located in the pterygopalatine fossa, the submandibular ganglion (located laterally to the hyoglossus muscle, below the lingual nerve, and the otic ganglion (located medially to the mandibular nerve, right beneath the oval foramen. The aim of this study was to present these structures in dissected anatomic specimens and perform a comparative analysis regarding location and morphology. The proximity of the ganglia and associated nerves were also analyzed, as well as the number and volume of fibers connected to them. Human heads were dissected by planes, partially removing the adjacent structures to the point we could reach the parasympathetic ganglia. With this study, we concluded that there was no significant variation regarding the location of the studied ganglia. Morphologically, our observations concur with previous classical descriptions of the parasympathetic ganglia, but we observed variations regarding the proximity of the otic ganglion to the mandibular nerve. We also observed that there were variations regarding the number and volume of fiber bundles connected to the submandibular, otic, and pterygopalatine ganglia.

  2. Computational investigation of nonlinear microwave tomography on anatomically realistic breast phantoms

    DEFF Research Database (Denmark)

    Jensen, P. D.; Rubæk, Tonny; Mohr, J. J.

    2013-01-01

    The performance of a nonlinear microwave tomography algorithm is tested using simulated data from anatomically realistic breast phantoms. These tests include several different anatomically correct breast models from the University of Wisconsin-Madison repository with and without tumors inserted....

  3. Anatomical Mercury: Changing Understandings of Quicksilver, Blood, and the Lymphatic System, 1650-1800.

    Science.gov (United States)

    Hendriksen, Marieke M A

    2015-10-01

    The use of mercury as an injection mass in anatomical experiments and preparations was common throughout Europe in the long eighteenth century, and refined mercury-injected preparations as well as plates of anatomical mercury remain today. The use and meaning of mercury in related disciplines such as medicine and chemistry in the same period have been studied, but our knowledge of anatomical mercury is sparse and tends to focus on technicalities. This article argues that mercury had a distinct meaning in anatomy, which was initially influenced by alchemical and classical understandings of mercury. Moreover, it demonstrates that the choice of mercury as an anatomical injection mass was deliberate and informed by an intricate cultural understanding of its materiality, and that its use in anatomical preparations and its perception as an anatomical material evolved with the understanding of the circulatory and lymphatic systems. By using the material culture of anatomical mercury as a starting point, I seek to provide a new, object-driven interpretation of complex and strongly interrelated historiographical categories such as mechanism, vitalism, chemistry, anatomy, and physiology, which are difficult to understand through a historiography that focuses exclusively on ideas. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. An exploration of the initial effects of stereoscopic displays on optometric parameters

    NARCIS (Netherlands)

    Fortuin, M.F.; Lambooij, M.T.M.; IJsselsteijn, W.A.; Heynderickx, I.E.J.; Edgar, D.F.; Evans, B.J.W.

    2011-01-01

    PURPOSE: To compare the effect on optometric variables of reading text presented in 2-D and 3-D on two types of stereoscopic display. METHODS: This study measured changes in binocular visual acuity, fixation disparity, aligning prism, heterophoria, horizontal fusional reserves, prism facility and

  5. The Effect of Information Analysis Automation Display Content on Human Judgment Performance in Noisy Environments

    Science.gov (United States)

    Bass, Ellen J.; Baumgart, Leigh A.; Shepley, Kathryn Klein

    2014-01-01

    Displaying both the strategy that information analysis automation employs to makes its judgments and variability in the task environment may improve human judgment performance, especially in cases where this variability impacts the judgment performance of the information analysis automation. This work investigated the contribution of providing either information analysis automation strategy information, task environment information, or both, on human judgment performance in a domain where noisy sensor data are used by both the human and the information analysis automation to make judgments. In a simplified air traffic conflict prediction experiment, 32 participants made probability of horizontal conflict judgments under different display content conditions. After being exposed to the information analysis automation, judgment achievement significantly improved for all participants as compared to judgments without any of the automation's information. Participants provided with additional display content pertaining to cue variability in the task environment had significantly higher aided judgment achievement compared to those provided with only the automation's judgment of a probability of conflict. When designing information analysis automation for environments where the automation's judgment achievement is impacted by noisy environmental data, it may be beneficial to show additional task environment information to the human judge in order to improve judgment performance. PMID:24847184

  6. The Effect of Information Analysis Automation Display Content on Human Judgment Performance in Noisy Environments.

    Science.gov (United States)

    Bass, Ellen J; Baumgart, Leigh A; Shepley, Kathryn Klein

    2013-03-01

    Displaying both the strategy that information analysis automation employs to makes its judgments and variability in the task environment may improve human judgment performance, especially in cases where this variability impacts the judgment performance of the information analysis automation. This work investigated the contribution of providing either information analysis automation strategy information, task environment information, or both, on human judgment performance in a domain where noisy sensor data are used by both the human and the information analysis automation to make judgments. In a simplified air traffic conflict prediction experiment, 32 participants made probability of horizontal conflict judgments under different display content conditions. After being exposed to the information analysis automation, judgment achievement significantly improved for all participants as compared to judgments without any of the automation's information. Participants provided with additional display content pertaining to cue variability in the task environment had significantly higher aided judgment achievement compared to those provided with only the automation's judgment of a probability of conflict. When designing information analysis automation for environments where the automation's judgment achievement is impacted by noisy environmental data, it may be beneficial to show additional task environment information to the human judge in order to improve judgment performance.

  7. Open-refrigerated retail display case temperature profile and its impact on product quality and microbiota of stored baby spinach

    Science.gov (United States)

    Open-refrigerated display cabinets are widely used in supermarkets and grocery chains around the globe. However, the temperature conditions in these display cases are variable which may impact product quality and safety. Therefore, we investigated the quality and microbiological populations of bagge...

  8. Prevention of postoperative visual field defect after the occipital transtentorial approach: anatomical study.

    Science.gov (United States)

    Matsuo, Satoshi; Baydin, Serhat; Güngör, Abuzer; Middlebrooks, Erik H; Komune, Noritaka; Iihara, Koji; Rhoton, Albert L

    2017-10-20

    OBJECTIVE A postoperative visual field defect resulting from damage to the occipital lobe during surgery is a unique complication of the occipital transtentorial approach. Though the association between patient position and this complication is well investigated, preventing the complication remains a challenge. To define the area of the occipital lobe in which retraction is least harmful, the surface anatomy of the brain, course of the optic radiations, and microsurgical anatomy of the occipital transtentorial approach were examined. METHODS Twelve formalin-fixed cadaveric adult heads were examined with the aid of a surgical microscope and 0° and 45° endoscopes. The optic radiations were examined by fiber dissection and MR tractography techniques. RESULTS The arterial and venous relationships of the lateral, medial, and inferior surfaces of the occipital lobe were defined anatomically. The full course of the optic radiations was displayed via both fiber dissection and MR tractography. Although the stems of the optic radiations as exposed by both techniques are similar, the terminations of the fibers are slightly different. The occipital transtentorial approach provides access for the removal of lesions involving the splenium, pineal gland, collicular plate, cerebellomesencephalic fissure, and anterosuperior part of the cerebellum. An angled endoscope can aid in exposing the superior medullary velum and superior cerebellar peduncles. CONCLUSIONS Anatomical findings suggest that retracting the inferior surface of the occipital lobe may avoid direct damage and perfusion deficiency around the calcarine cortex and optic radiations near their termination. An accurate understanding of the course of the optic radiations and vascular relationships around the occipital lobe and careful retraction of the inferior surface of the occipital lobe may reduce the incidence of postoperative visual field defect.

  9. Why can't rodents vomit? A comparative behavioral, anatomical, and physiological study.

    Directory of Open Access Journals (Sweden)

    Charles C Horn

    Full Text Available The vomiting (emetic reflex is documented in numerous mammalian species, including primates and carnivores, yet laboratory rats and mice appear to lack this response. It is unclear whether these rodents do not vomit because of anatomical constraints (e.g., a relatively long abdominal esophagus or lack of key neural circuits. Moreover, it is unknown whether laboratory rodents are representative of Rodentia with regards to this reflex. Here we conducted behavioral testing of members of all three major groups of Rodentia; mouse-related (rat, mouse, vole, beaver, Ctenohystrica (guinea pig, nutria, and squirrel-related (mountain beaver species. Prototypical emetic agents, apomorphine (sc, veratrine (sc, and copper sulfate (ig, failed to produce either retching or vomiting in these species (although other behavioral effects, e.g., locomotion, were noted. These rodents also had anatomical constraints, which could limit the efficiency of vomiting should it be attempted, including reduced muscularity of the diaphragm and stomach geometry that is not well structured for moving contents towards the esophagus compared to species that can vomit (cat, ferret, and musk shrew. Lastly, an in situ brainstem preparation was used to make sensitive measures of mouth, esophagus, and shoulder muscular movements, and phrenic nerve activity-key features of emetic episodes. Laboratory mice and rats failed to display any of the common coordinated actions of these indices after typical emetic stimulation (resiniferatoxin and vagal afferent stimulation compared to musk shrews. Overall the results suggest that the inability to vomit is a general property of Rodentia and that an absent brainstem neurological component is the most likely cause. The implications of these findings for the utility of rodents as models in the area of emesis research are discussed.

  10. Comparative epidermal anatomical studies in six taxa of genus Nephrolepis Swart in Nigeria

    Directory of Open Access Journals (Sweden)

    A. A. Fajuke

    2018-04-01

    Full Text Available Anatomical studies in six taxa of genus Nephrolepis; N. biserrata, N. cordifolia, N. exaltata (i & (ii, N. biserrata var. furcans and N. undulata were carried out with a view to identify anatomic characters of taxonomic values. Both qualitative and quantitative anatomical studies were carried out. Quantitative data were subjected to descriptive statistical analysis. Anatomical characters studied include venation patterns, trichome types, presence and absence of stomata and values of the stomatal index which are valuable in delimiting the species. The overall results showed overlaps in the quantitative anatomical attributes of the Nephrolepis taxa studied suggesting that they belong to the same genus. Qualitative anatomical attributes that separated the genus into distinct taxa are the presence of simple multicellular glandular trichomes in N. biserrata and simple multicellular non-glandular trichomes in N. exaltata (i and N. exalta (ii while N. biserrata var. furcans and N. undulata have simple unicellular non-glandular trichomes and absence of trichome in N. cordifolia. Presence of anisocytic, diacytic or anomocytic stomata were of diagnostic important in the six taxa.

  11. The heat engine cycle, the heat removal cycle, and ergonomics of the control room displays

    International Nuclear Information System (INIS)

    Beltracchi, L.

    1986-01-01

    This paper discusses and illustrates the ergonomics of an integrated display, which will allow operators to monitor the heat engine cycle during normal operation of the plant, and the heat removal cycle during emergency operation of the plant. A computer-based iconic display is discussed as an overview to monitor these cycles. Specific emphasis is placed upon the process variables and process functions within each cycle, and the action of control systems and engineered safeguard systems within each cycle. This paper contains examples of display formats for the heat engine cycle and the heat removal cycle in a pressurized water reactor

  12. The clinical importance of the anatomic variations in the paranasal sinuses

    International Nuclear Information System (INIS)

    Teixeira Junior, Francisco Ribeiro; Bretas, Elisa Almeida Sathler; Madeira, Ivana Andrade; Diniz, Renata Furletti; Ribeiro, Marcelo Almeida; Motta, Emilia Guerra Pinto Coelho; Moreira, Wanderval

    2008-01-01

    The anatomic variations of the paranasal sinuses are common findings. The importance of such variations predisposing disease through the obstruction of the drainage pathway has been discussed by several authors, although it is not yet a matter of agreement. The literature was reviewed and a iconographic assay was prepared aiming the discussion of the importance of the main anatomic variations of the paranasal sinuses. The prevalence of anatomic variations of the paranasal sinuses varies largely amongst studies and its role in sinus disease is controversial. In this article, it is described the different variations associated to paranasal disease and how they relate to pathologic conditions. Most studies confirm the concept that anatomic variations of the paranasal sinuses are related to disease when they obstruct the drainage pathways. The knowledge of such alterations and its relations to pathologic conditions is expected from the general radiologist. (author)

  13. An efficient method for isolating antibody fragments against small peptides by antibody phage display

    DEFF Research Database (Denmark)

    Duan, Zhi; Siegumfeldt, Henrik

    2010-01-01

    We generated monoclonal scFv (single chain variable fragment) antibodies from an antibody phage display library towards three small synthetic peptides derived from the sequence of s1-casein. Key difficulties for selection of scFv-phages against small peptides were addressed. Small peptides do....... The scFvs were sequenced and characterized, and specificity was characterized by ELISA. The methods developed in this study are universally applicable for antibody phage display to efficiently produce antibody fragments against small peptides....

  14. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  15. Anatomical models and wax Venuses: art masterpieces or scientific craft works?

    Science.gov (United States)

    Ballestriero, R

    2010-02-01

    The art of wax modelling has an ancient origin but rose to prominence in 14th century Italy with the cult of votive artefacts. With the advent of Neoclassicism this art, now deemed repulsive, continued to survive in a scientific environment, where it flourished in the study of normal and pathological anatomy, obstetrics, zoology and botany. The achievement of having originated the creation of anatomical models in coloured wax must be ascribed to a joint effort undertaken by the Sicilian wax modeller Gaetano Giulio Zumbo and the French surgeon Guillaume Desnoues in the late 17th century. Interest in anatomical wax models spread throughout Europe during the 18th century, first in Bologna with Ercole Lelli, Giovanni Manzolini and Anna Morandi, and then in Florence with Felice Fontana and Clemente Susini. In England, the art of anatomical ceroplastics was brought to London from Florence by the sculptor Joseph Towne. Throughout the centuries many anatomical artists preferred this material due to the remarkable mimetic likeness obtained, far surpassing any other material. Independent of the material used, whether wood, wax or clay, anatomical models were always considered merely craft works confined to hospitals or faculties of medicine and have survived to this day only because of their scientific interest. Italian and English waxes are stylistically different but the remarkable results obtained by Susini and Towne, and the fact that some contemporary artists are again representing anatomical wax bodies in their works, makes the border that formerly separated art and craft indistinguishable.

  16. How accurate is anatomic limb alignment in predicting mechanical limb alignment after total knee arthroplasty?

    Science.gov (United States)

    Lee, Seung Ah; Choi, Sang-Hee; Chang, Moon Jong

    2015-10-27

    Anatomic limb alignment often differs from mechanical limb alignment after total knee arthroplasty (TKA). We sought to assess the accuracy, specificity, and sensitivity for each of three commonly used ranges for anatomic limb alignment (3-9°, 5-10° and 2-10°) in predicting an acceptable range (neutral ± 3°) for mechanical limb alignment after TKA. We also assessed whether the accuracy of anatomic limb alignment was affected by anatomic variation. This retrospective study included 314 primary TKAs. The alignment of the limb was measured with both anatomic and mechanical methods of measurement. We also measured anatomic variation, including the femoral bowing angle, tibial bowing angle, and neck-shaft angle of the femur. All angles were measured on the same full-length standing anteroposterior radiographs. The accuracy, specificity, and sensitivity for each range of anatomic limb alignment were calculated and compared using mechanical limb alignment as the reference standard. The associations between the accuracy of anatomic limb alignment and anatomic variation were also determined. The range of 2-10° for anatomic limb alignment showed the highest accuracy, but it was only 73 % (3-9°, 65 %; 5-10°, 67 %). The specificity of the 2-10° range was 81 %, which was higher than that of the other ranges (3-9°, 69 %; 5-10°, 67 %). However, the sensitivity of the 2-10° range to predict varus malalignment was only 16 % (3-9°, 35 %; 5-10°, 68 %). In addition, the sensitivity of the 2-10° range to predict valgus malalignment was only 43 % (3-9°, 71 %; 5-10°, 43 %). The accuracy of anatomical limb alignment was lower for knees with greater femoral (odds ratio = 1.2) and tibial (odds ratio = 1.2) bowing. Anatomic limb alignment did not accurately predict mechanical limb alignment after TKA, and its accuracy was affected by anatomic variation. Thus, alignment after TKA should be assessed by measuring mechanical alignment rather than anatomic

  17. The effect of percutaneous transcatheter occlusion of left atrial appendage on left atrium and adjacent anatomic structure in canine

    International Nuclear Information System (INIS)

    Yang Zhihong; Wu Hong; Qin Yongwen; Hu Jianqiang; Ding Zhongru; Liu Zongjun; Liu Biao; Zheng Xing

    2009-01-01

    Objective: To observe the effect of percutaneous transcatheter occlusion of left atrial appendage (LAA) with a new self-manufactured LAA occluder on left atrium and adjacent anatomic structure in canine. Methods: A new self-manufactured LAA occluder was implanted into the LAA through a transseptal catheter in 20 dogs. Before and after the procedure, the experimental dogs were anaesthetized and examined by transthoracic echocardiography (TTE) to measure the diameter and the volume of the left atrium, the left superior pulmonary vein flow velocity and the left atrioventricular valve flow velocity separately. The contrast radiography of the LAA and the left coronary arteriography were performed. Results: The new LAA occluder was implanted successfully in 14 dogs. No obvious changes in the diameter and the volume of the left atrium, in left superior pulmonary vein flow velocity and in left atrioventricular valve flow velocity were found. On arteriography, left circumflex artery was normally displayed after the procedure. No migration of the occluder was seen on TTE and angiography after procedure. Conclusion: Percutaneous transcatheter occlusion of left atrial appendage with a new self-manufactured LAA occluder has no obvious effect on left atrium and adjacent anatomic structure in experimental canine, which indicates that the new-type device is a safe and feasible occluder for LAA. (authors)

  18. JAVA Stereo Display Toolkit

    Science.gov (United States)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  19. Semi-automated Anatomical Labeling and Inter-subject Warping of High-Density Intracranial Recording Electrodes in Electrocorticography

    Directory of Open Access Journals (Sweden)

    Liberty S. Hamilton

    2017-10-01

    Full Text Available In this article, we introduce img_pipe, our open source python package for preprocessing of imaging data for use in intracranial electrocorticography (ECoG and intracranial stereo-EEG analyses. The process of electrode localization, labeling, and warping for use in ECoG currently varies widely across laboratories, and it is usually performed with custom, lab-specific code. This python package aims to provide a standardized interface for these procedures, as well as code to plot and display results on 3D cortical surface meshes. It gives the user an easy interface to create anatomically labeled electrodes that can also be warped to an atlas brain, starting with only a preoperative T1 MRI scan and a postoperative CT scan. We describe the full capabilities of our imaging pipeline and present a step-by-step protocol for users.

  20. Presence of Cognitive Deterioration and Anatomical-Clinical Topography in Patients with Epilepsy in Cienfuegos

    Directory of Open Access Journals (Sweden)

    Rolando Lázaro Rivera López

    2015-02-01

    Full Text Available Background: epilepsy is a pathological condition characterized by a recurrent non-provoked crisis, however, the presence of the crisis is a fraction of the global problem, patients with epilepsy develop a variety of neuropsychiatry problems, as cognitive affection, most of all, in the space of memory. Objective: evaluating the behavior of the cognitive deterioration and focalization according to anatomical- clinical topography in patients with epilepsy. Methods: a descriptive, correlational, cross-section and follow-up study of cases. The techniques used were: structured interview, the Montreal Cognitive Assessment's evaluation, and Luria´s neuropsychological exam. It was used SPDD statical parcel, version 1.5 to process the information that made possible the study of the obtained data, with the aim of expressing the results in chart of frequency and relation of variables in number and percent. Results: the 71.4 % of evaluated patients presented cognitive deterioration in any of its of measurement scales and they focalized according to neuropsychological exam. Conclusions: as the time of evolution of the disease increases, the frequency and duration of the crises, the grade of the cognitive deterioration in patients with epilepsy increases, focalizing with dysfunction majority fronto-temporary level according to anatomical-clinical topography.

  1. Latest development of display technologies

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Yao Qiu-Xiang; Liu Pan; Zheng Zhi-Qiang; Liu Ji-Cheng; Zheng Hua-Dong; Zeng Chao; Yu Ying-Jie; Sun Tao; Zeng Zhen-Xiang

    2016-01-01

    In this review we will focus on recent progress in the field of two-dimensional (2D) and three-dimensional (3D) display technologies. We present the current display materials and their applications, including organic light-emitting diodes (OLEDs), flexible OLEDs quantum dot light emitting diodes (QLEDs), active-matrix organic light emitting diodes (AMOLEDs), electronic paper (E-paper), curved displays, stereoscopic 3D displays, volumetric 3D displays, light field 3D displays, and holographic 3D displays. Conventional 2D display devices, such as liquid crystal devices (LCDs) often result in ambiguity in high-dimensional data images because of lacking true depth information. This review thus provides a detailed description of 3D display technologies. (topical review)

  2. Anatomical Changes and Audiological Profile in Branchio-oto-renal Syndrome: A Literature Review

    Directory of Open Access Journals (Sweden)

    Lindau, Tâmara Andrade

    2014-01-01

    Full Text Available Introduction Branchio-oto-renal (BOR syndrome is an autosomal-dominant genetic condition with high penetrance and variable expressivity, with an estimated prevalence of 1 in 40,000. Approximately 40% of the patients with the syndrome have mutations in the gene EYA1, located at chromosomal region 8q13.3, and 5% have mutations in the gene SIX5 in chromosome region 19q13. The phenotype of this syndrome is characterized by preauricular fistulas; structural malformations of the external, middle, and inner ears; branchial fistulas; renal disorders; cleft palate; and variable type and degree of hearing loss. Aim Hearing loss is part of BOR syndrome phenotype. The aim of this study was to present a literature review on the anatomical aspects and audiological profile of BOR syndrome. Data Synthesis Thirty-four studies were selected for analysis. Some aspects when specifying the phenotype of BOR syndrome are controversial, especially those issues related to the audiological profile in which there was variability on auditory standard, hearing loss progression, and type and degree of the hearing loss. Mixed loss was the most common type of hearing loss among the studies; however, there was no consensus among studies regarding the degree of the hearing loss.

  3. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology and Institute of Oral Bio Science, College of Dentistry, Chonbuk National University, Chonju (Korea, Republic of); Park, Mi Ju [Dept. of Prosthodontics, School of Denstistry, Chonbuk National Universty, Chonju (Korea, Republic of)

    1999-08-15

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  4. Computerized Tomographic Study on the Anatomic Variation of the Paranasal Sinus

    International Nuclear Information System (INIS)

    Choi, Sun Kyung; Lim, Sug Young; Koh, Kwang Joon; Park, Mi Ju

    1999-01-01

    To evaluate the anatomic variations of the paranasal sinuses on computed tomographs. The author examined the CT images of the paranasal sinuses retrospectively in 500 patients who visited Chonbuk National University Hospital between January 1996 and December 1997. The highest incidence of anatomic variation of the paranasal sinuses in bilateral structures was agger nasi cell (73.2%), followed by concha bullosa (31.1%), Onodi cell (24.0%), Haller cell (19.8%), maxillary sinus septum (13.0%), paradoxical middle turbinate (2.5%), pneumatized uncinate process (2.0%), and bent uncinate process. The highest incidence of anatomic variation in midline structures was nasal septum deviation(53.2%), followed by nasal septumaerated (29.4%), bulla galli (24.7%) asymmetric intersphenoid septum (22.3%), and nasal septum spur (13.8%). The correlation between anatomic variation and paranasal sinusitis was not found. The results of this study will aid in the diagnosis and treatment of paranasal sinus diseases, especially in the treatment planning before functional endoscopic surgery.

  5. Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks

    Science.gov (United States)

    Fayad, Hadi; Pan, Tinsu; Clément, Jean-François; Visvikis, Dimitris

    2011-01-01

    Purpose Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signals over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the entire patient external surface in real time. The main objective of this study was to assess the motion correlation between such an external patient surface and internal anatomical landmarks motion. Methods Four dimensional Computed Tomography (4D CT) volumes for ten patients were used in this study. Anatomical landmarks were manually selected in the thoracic region across the 4D CT datasets by two experts. The landmarks included normal structures as well as the tumour location. In addition, a distance map representing the entire external patient surface, which corresponds to surfaces acquired by a Time of Flight (ToF) camera or similar devices, was created by segmenting the skin of all 4D CT volumes using a thresholding algorithm. Finally, the correlation between the internal landmarks and external surface motion was evaluated for different regions (placement and size) throughout a patient’s surface. Results Significant variability was observed in the motion of the different parts of the external patient surface. The larger motion magnitude was consistently measured in the central regions of the abdominal and the thoracic areas for the different patient datasets considered. The highest correlation coefficients were observed between the motion of these external surface areas and internal landmarks such as the diaphragm and mediastinum structures as well as the tumour location landmarks (0.8 ± 0.18 and 0.72 ± 0.12 for the abdominal and the thoracic regions respectively). Worse correlation was observed when one considered landmarks not significantly influenced by respiratory motion such as the apex and the sternum. Discussion and conclusions There

  6. Displays and simulators

    Science.gov (United States)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  7. Displays enabling mobile multimedia

    Science.gov (United States)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  8. On Integrity of Flexible Displays

    Science.gov (United States)

    Bouten, Piet C. P.

    Nowadays two display types are dominant in the display market: the bulky cathode ray tube (CRT) and liquid crystal displays (LCD). Both types use glass as substrate material. The LCD display is the dominant player for mobile applications, in for instance mobile phones and portable computers. In the development of displays and their applications a clear interest exists to replace the rigid rectangular display cells by free-shaped, curved or even roll-up cells. These types of applications require flexible displays.

  9. Anatomical studies on the development of Metasequoia glyptostroboides Hu et Cheng wood

    Directory of Open Access Journals (Sweden)

    Alina Hejnowicz

    2015-01-01

    Full Text Available Variability of anatomical characters within a 15 year old stem is presented by the method of contour lines, where against a schematic longitudinal section of a stem points corresponding to the same values for a character are joined by lines, similarly as altitudes in cartography. The method permits prediction of future trends in character changes. It was thus established that tracheid dimensions and diameter of bordered pits in early wood tracheids increase with age of tree and do not reach maximal values before the 15th year. The annual ring width and the height of the rays attain maximal values before the 15th year while the dimensions of ray cells and the percentage of late wood reach almost constant values during the first year or two.

  10. Anatomical masking of pressure footprints based on the Oxford Foot Model: validation and clinical relevance.

    Science.gov (United States)

    Giacomozzi, Claudia; Stebbins, Julie A

    2017-03-01

    Plantar pressure analysis is widely used in the assessment of foot function. In order to assess regional loading, a mask is applied to the footprint to sub-divide it into regions of interest (ROIs). The most common masking method is based on geometric features of the footprint (GM). Footprint masking based on anatomical landmarks of the foot has been implemented more recently, and involves the integration of a 3D motion capture system, plantar pressure measurement device, and a multi-segment foot model. However, thorough validation of anatomical masking (AM) using pathological footprints has not yet been presented. In the present study, an AM method based on the Oxford Foot Model (OFM) was compared to an equivalent GM. Pressure footprints from 20 young healthy subjects (HG) and 20 patients with clubfoot (CF) were anatomically divided into 5 ROIs using a subset of the OFM markers. The same foot regions were also identified by using a standard GM method. Comparisons of intra-subject coefficient of variation (CV) showed that the OFM-based AM was at least as reliable as the GM for all investigated pressure parameters in all foot regions. Clinical relevance of AM was investigated by comparing footprints from HG and CF groups. Contact time, maximum force, force-time integral and contact area proved to be sensitive parameters that were able to distinguish HG and CF groups, using both AM and GM methods However, the AM method revealed statistically significant differences between groups in 75% of measured variables, compared to 62% using a standard GM method, indicating that the AM method is more sensitive for revealing differences between groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Monitoring the quality of cardiac surgery based on three or more surgical outcomes using a new variable life-adjusted display.

    Science.gov (United States)

    Gan, Fah Fatt; Tang, Xu; Zhu, Yexin; Lim, Puay Weng

    2017-06-01

    The traditional variable life-adjusted display (VLAD) is a graphical display of the difference between expected and actual cumulative deaths. The VLAD assumes binary outcomes: death within 30 days of an operation or survival beyond 30 days. Full recovery and bedridden for life, for example, are considered the same outcome. This binary classification results in a great loss of information. Although there are many grades of survival, the binary outcomes are commonly used to classify surgical outcomes. Consequently, quality monitoring procedures are developed based on binary outcomes. With a more refined set of outcomes, the sensitivities of these procedures can be expected to improve. A likelihood ratio method is used to define a penalty-reward scoring system based on three or more surgical outcomes for the new VLAD. The likelihood ratio statistic W is based on testing the odds ratio of cumulative probabilities of recovery R. Two methods of implementing the new VLAD are proposed. We accumulate the statistic W-W¯R to estimate the performance of a surgeon where W¯R is the average of the W's of a historical data set. The accumulated sum will be zero based on the historical data set. This ensures that if a new VLAD is plotted for a future surgeon of performance similar to this average performance, the plot will exhibit a horizontal trend. For illustration of the new VLAD, we consider 3-outcome surgical results: death within 30 days, partial and full recoveries. In our first illustration, we show the effect of partial recoveries on surgical results of a surgeon. In our second and third illustrations, the surgical results of two surgeons are compared using both the traditional VLAD based on binary-outcome data and the new VLAD based on 3-outcome data. A reversal in relative performance of surgeons is observed when the new VLAD is used. In our final illustration, we display the surgical results of four surgeons using the new VLAD based completely on 3-outcome data. Full

  12. Touching Anatomy. : On the Handling of Anatomical Preparations in the Anatomical Cabinets of Frederik Ruysch (1638-1731)

    NARCIS (Netherlands)

    Knoeff, Rina

    2015-01-01

    This paper argues that the anatomical Cabinets of Dutch anatomist Frederik Ruysch must be understood as an early modern workshop in which preparations were continuously handled. It is claimed that preparations actively appealed to anatomists and visitors to handle, re-dissect, touch, and even kiss

  13. Anatomically Plausible Surface Alignment and Reconstruction

    DEFF Research Database (Denmark)

    Paulsen, Rasmus R.; Larsen, Rasmus

    2010-01-01

    With the increasing clinical use of 3D surface scanners, there is a need for accurate and reliable algorithms that can produce anatomically plausible surfaces. In this paper, a combined method for surface alignment and reconstruction is proposed. It is based on an implicit surface representation...

  14. A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability and sensitivity in pediatric planovalgus feet.

    Science.gov (United States)

    Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B; D'Astous, Jacques L

    2013-01-01

    Several multisegment foot models have been proposed and some have been used to study foot pathologies. These models have been tested and validated on typically developed populations; however application of such models to feet with significant deformities presents an additional set of challenges. For the first time, in this study, a multisegment foot model is tested for repeatability in a population of children with symptomatic abnormal feet. The results from this population are compared to the same metrics collected from an age matched (8-14 years) typically developing population. The modified Shriners Hospitals for Children, Greenville (mSHCG) foot model was applied to ten typically developing children and eleven children with planovalgus feet by two clinicians. Five subjects in each group were retested by both clinicians after 4-6 weeks. Both intra-clinician and inter-clinician repeatability were evaluated using static and dynamic measures. A plaster mold method was used to quantify variability arising from marker placement error. Dynamic variability was measured by examining trial differences from the same subjects when multiple clinicians carried out the data collection multiple times. For hindfoot and forefoot angles, static and dynamic variability in both groups was found to be less than 4° and 6° respectively. The mSHCG model strategy of minimal reliance on anatomical markers for dynamic measures and inherent flexibility enabled by separate anatomical and technical coordinate systems resulted in a model equally repeatable in typically developing and planovalgus populations. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Book Display as Adult Service

    Directory of Open Access Journals (Sweden)

    Matthew S. Moore

    1997-03-01

    Full Text Available 無Book display as an adult service is defined as choosing and positioning adult books from the collection to increase their circulation. The author contrasts bookstore arrangement for sales versus library arrangement for access. The paper considers the library-as-a-whole as a display, examines the right size for an in-library display, and discusses mass displays, end-caps, on-shelf displays, and the Tiffany approach. The author proposes that an effective display depends on an imaginative, unifying theme, and that book displays are part of the joy of libraries.

  16. [Anatomic rationale for clinical efficacy of intraosseous mental nerve anesthesia].

    Science.gov (United States)

    Rabinovich, S A; Vasil'ev, Yu L; Kuzin, A N

    2018-01-01

    The aim of the study was to prove the anatomical and clinical effectiveness of the modified anesthesia of mental nerve. The effectiveness of conductive anesthesia near the mental foramen was objectively evaluated using the electric pulp test (EPT) in 100 volunteers of both sexes, aged 35-43 years. Wet anterior mandible preparations obtained from 350 cadavers aged 18-74 years were also studied. EPT value after local mental anesthesia conducted according to Malamed C. using 4% articain solution of local anesthetic with vasoconstrictor concentration of 1:200.000 after 2 minutes was 93±0.82 mA, after 4 minutes - 188±1.26 mA. Yield variability indicators of intraosseous mental nerve anesthesia was slightly higher varying from 94.11 mA to 96.61 mA after 2 minutes and from 197.4 to 199.92 mA after 4 minutes survey. The study showed the efficiency and predictability of intraosseous anesthesia of the mental nerve.

  17. Anatomical Parameters of tDCS to Modulate the Motor System after Stroke: A Review

    Science.gov (United States)

    Lefebvre, Stephanie; Liew, Sook-Lei

    2017-01-01

    Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation method to modulate the local field potential in neural tissue and consequently, cortical excitability. As tDCS is relatively portable, affordable, and accessible, the applications of tDCS to probe brain–behavior connections have rapidly increased in the last 10 years. One of the most promising applications is the use of tDCS to modulate excitability in the motor cortex after stroke and promote motor recovery. However, the results of clinical studies implementing tDCS to modulate motor excitability have been highly variable, with some studies demonstrating that as many as 50% or more of patients fail to show a response to stimulation. Much effort has therefore been dedicated to understand the sources of variability affecting tDCS efficacy. Possible suspects include the placement of the electrodes, task parameters during stimulation, dosing (current amplitude, duration of stimulation, frequency of stimulation), individual states (e.g., anxiety, motivation, attention), and more. In this review, we first briefly review potential sources of variability specific to stroke motor recovery following tDCS. We then examine how the anatomical variability in tDCS placement [e.g., neural target(s) and montages employed] may alter the neuromodulatory effects that tDCS exerts on the post-stroke motor system. PMID:28232816

  18. Children's Control/Display Stereotypes.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  19. Gyration of the feline brain: localization, terminology and variability.

    Science.gov (United States)

    Pakozdy, A; Angerer, C; Klang, A; König, E H; Probst, A

    2015-12-01

    The terminology of feline brain gyration is not consistent and individual variability has not been systematically examined. The aim of the study was to identify the gyri and sulci of cat brains and describe them using the current terminology. The brains of 15 cats including 10 European shorthairs, 2 Siamese, 2 Maine coons and one Norvegian forest cat without clinical evidence of brain disease were examined post-mortem and photographed for documentation. For description, the terms of the most recent Nomina Anatomica Veterinaria (NAV, 2012) were used, and comparisons with previous anatomical texts were also performed. In addition to the lack of comparative morphology in the NAV, veterinary and human nomenclature are used interchangeably and inconsistently in the literature. This presents a challenge for neurologists and anatomists in localizing gyri and sulci. A comparative analysis of brain gyration showed only minor individual variability among the cats. High-quality labelled figures are provided to facilitate the identification of cat brain gyration. Our work consolidates the current and more consistent gyration terminology for reporting the localization of a cortical lesion based on magnetic resonance imaging or histopathology. This will facilitate not only morphological but also functional research using accurate anatomical reporting. © 2014 Blackwell Verlag GmbH.

  20. Retrieving high-resolution images over the Internet from an anatomical image database

    Science.gov (United States)

    Strupp-Adams, Annette; Henderson, Earl

    1999-12-01

    The Visible Human Data set is an important contribution to the national collection of anatomical images. To enhance the availability of these images, the National Library of Medicine has supported the design and development of a prototype object-oriented image database which imports, stores, and distributes high resolution anatomical images in both pixel and voxel formats. One of the key database modules is its client-server Internet interface. This Web interface provides a query engine with retrieval access to high-resolution anatomical images that range in size from 100KB for browser viewable rendered images, to 1GB for anatomical structures in voxel file formats. The Web query and retrieval client-server system is composed of applet GUIs, servlets, and RMI application modules which communicate with each other to allow users to query for specific anatomical structures, and retrieve image data as well as associated anatomical images from the database. Selected images can be downloaded individually as single files via HTTP or downloaded in batch-mode over the Internet to the user's machine through an applet that uses Netscape's Object Signing mechanism. The image database uses ObjectDesign's object-oriented DBMS, ObjectStore that has a Java interface. The query and retrieval systems has been tested with a Java-CDE window system, and on the x86 architecture using Windows NT 4.0. This paper describes the Java applet client search engine that queries the database; the Java client module that enables users to view anatomical images online; the Java application server interface to the database which organizes data returned to the user, and its distribution engine that allow users to download image files individually and/or in batch-mode.

  1. An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Audenaert, Emmanuel; Speleers, Bruno; Vercauteren, Tom; Mulliez, Thomas; Vandemaele, Pieter; Achten, Eric; Kerckaert, Ingrid; D'Herde, Katharina; De Neve, Wilfried; Van Hoof, Tom

    2013-01-01

    Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection

  2. Renal Tumor Anatomic Complexity: Clinical Implications for Urologists.

    Science.gov (United States)

    Joshi, Shreyas S; Uzzo, Robert G

    2017-05-01

    Anatomic tumor complexity can be objectively measured and reported using nephrometry. Various scoring systems have been developed in an attempt to correlate tumor complexity with intraoperative and postoperative outcomes. Nephrometry may also predict tumor biology in a noninvasive, reproducible manner. Other scoring systems can help predict surgical complexity and the likelihood of complications, independent of tumor characteristics. The accumulated data in this new field provide provocative evidence that objectifying anatomic complexity can consolidate reporting mechanisms and improve metrics of comparisons. Further prospective validation is needed to understand the full descriptive and predictive ability of the various nephrometry scores. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Sonographic and Anatomic Description of the Subtalar Joint

    DEFF Research Database (Denmark)

    Mandl, Peter; Bong, David; Balint, Peter V

    2018-01-01

    Our study provides a detailed anatomic and sonographic description of the subtalar joint, a single joint that, anatomically, is divided into the anterior subtalar joint (ASTJ) and the posterior subtalar joint (PSTJ). Cadaver specimens of the ankle and foot were examined in detail by ultrasound (US......), and the subtalar joints of all the specimens were injected with colored latex of a contrasting color under US guidance. Compatible with other studies, examination of the sections revealed lack of communication between the ASTJ and the PSTJ and communication between the PSTJ and the posterior recess...... of agreement between images acquired in cadaver specimens and images acquired in four centers using healthy patients....

  4. Testing the deGroot recall paradigm to evaluate displays for operating personnel

    International Nuclear Information System (INIS)

    Moray, N.; Jones, B.G.; Rasmussen, J.

    1991-01-01

    In this paper the authors report the results of experiments based on deGroot's work to assess the value of memory tests for measuring the quality of displays and the level of expertise of operators. Three kinds of display and people with three levels of expertise were included in the experiments. The displays were computer generated versions of traditional analog meters, traditional analog meters supplemented by a dynamic graphic representing the relation between temperature and pressure in some subsystems, and a dynamic graphic representing the underlying thermodynamics of power generation using the Rankine Cycle. The levels of expertise were represented by undergraduates with one semester of thermodynamics, graduate students of thermodynamics and nuclear engineering, and professional nuclear power plant operators. Each group watched a set of transients presented on the displays, using data generated by a high fidelity NPP training simulator, and were then asked three kinds of questions. The first measured their ability to recall the exact values of system state variables. The second measured their ability to recall what qualitative states the system had entered during the transient. The third measured their ability diagnose the nature of the transient. The results of the experiments are reported in relation to the possible use of memory tests to evaluate displays and the interaction of the quality of displays with the level of expertise of operators

  5. Development and preliminary evaluation of a new anatomically based prosthetic alignment method for below-knee prosthesis.

    Science.gov (United States)

    Tafti, Nahid; Karimlou, Masoud; Mardani, Mohammad Ali; Jafarpisheh, Amir Salar; Aminian, Gholam Reza; Safari, Reza

    2018-04-20

    The objectives of current study were to a) assess similarities and relationships between anatomical landmark-based angles and distances of lower limbs in unilateral transtibial amputees and b) develop and evaluate a new anatomically based static prosthetic alignment method. First sub-study assessed the anthropometrical differences and relationships between the lower limbs in the photographs taken from amputees. Data were analysed via paired t-test and regression analysis. Results show no significant differences in frontal and transverse planes. In the sagittal plane, the anthropometric parameters of the amputated limb were significantly correlated to the corresponding variables of the sound limb. The results served as bases for the development of a new prosthetic alignment method. The method was evaluated on a single subject study. Prosthetic alignment carried out by an experienced prosthetist was compared with such alignment adjusted by an inexperienced prosthetist but with the use of the developed method. In sagittal and frontal planes, the socket angle was tuned with respect to the shin angle, and the position of the prosthetic foot was tuned in relation to the pelvic landmarks. Further study is needed to assess the proposed method on a larger sample of amputees and prosthetists.

  6. Chronic ankle instability: Arthroscopic anatomical repair.

    Science.gov (United States)

    Arroyo-Hernández, M; Mellado-Romero, M; Páramo-Díaz, P; García-Lamas, L; Vilà-Rico, J

    Ankle sprains are one of the most common injuries. Despite appropriate conservative treatment, approximately 20-40% of patients continue to have chronic ankle instability and pain. In 75-80% of cases there is an isolated rupture of the anterior talofibular ligament. A retrospective observational study was conducted on 21 patients surgically treated for chronic ankle instability by means of an arthroscopic anatomical repair, between May 2012 and January 2013. There were 15 men and 6 women, with a mean age of 30.43 years (range 18-48). The mean follow-up was 29 months (range 25-33). All patients were treated by arthroscopic anatomical repair of anterior talofibular ligament. Four (19%) patients were found to have varus hindfoot deformity. Associated injuries were present in 13 (62%) patients. There were 6 cases of osteochondral lesions, 3 cases of posterior ankle impingement syndrome, and 6 cases of peroneal pathology. All these injuries were surgically treated in the same surgical time. A clinical-functional study was performed using the American Orthopaedic Foot and Ankle Society (AOFAS) score. The mean score before surgery was 66.12 (range 60-71), and after surgery it increased up to a mean of 96.95 (range 90-100). All patients were able to return to their previous sport activity within a mean of 21.5 weeks (range 17-28). Complications were found in 3 (14%) patients. Arthroscopic anatomical ligament repair technique has excellent clinical-functional results with a low percentage of complications, and enables patients to return to their previous sport activity within a short period of time. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Augmenting digital displays with computation

    Science.gov (United States)

    Liu, Jing

    As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion

  8. Anatomic variation in the origin of the main renal arteries: spiral CTA evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beregi, J.P.; Willoteaux, S.; Remy-Jardin, M. [Department of Vascular Radiology, Hopital Cardiologique, 59 - Lille (France); Mauroy, B.; Francke, J.P. [Laboratoire d`Anatomie, Univ. de Lille (France); Mounier-Vehier, C. [Department of Hypertension and Internal Medicine, Hopital Cardiologique, Lille (France)

    1999-09-01

    The aim of this study was to provide quantitative data on the origin and trajectory of the main renal arteries using spiral CT angiography and arteriography. Normal renal artery anatomy was assessed on spiral CT angiography (axial transverse sections and shaded-surface-display reconstructions) in 100 patients referred for renal arteriography who had no significant renal artery stenosis. Two hundred major renal arteries were studied. The vast majority of right (88 %) and left (87 %) renal arteries originated between the lower third of the first lumbar vertebra and the lower border of the second lumbar vertebra. In 50 patients both ostia were at the same level; in the remaining 50 patients, the right ostium was located above the left in 37 patients. On the right, the angle of origin varied from -10 to + 55 (mean + 24 ). On the left, the angle of origin varied from + 30 to -55 (mean -11 ). Spiral CT angiography provides additional anatomic data, notably regarding the angle of origin of the renal arteries, that is potentially useful for planning interventional procedures. (orig.) With 4 figs., 19 refs.

  9. Anatomic variation in the origin of the main renal arteries: spiral CTA evaluation

    International Nuclear Information System (INIS)

    Beregi, J.P.; Willoteaux, S.; Remy-Jardin, M.; Mauroy, B.; Francke, J.P.; Mounier-Vehier, C.

    1999-01-01

    The aim of this study was to provide quantitative data on the origin and trajectory of the main renal arteries using spiral CT angiography and arteriography. Normal renal artery anatomy was assessed on spiral CT angiography (axial transverse sections and shaded-surface-display reconstructions) in 100 patients referred for renal arteriography who had no significant renal artery stenosis. Two hundred major renal arteries were studied. The vast majority of right (88 %) and left (87 %) renal arteries originated between the lower third of the first lumbar vertebra and the lower border of the second lumbar vertebra. In 50 patients both ostia were at the same level; in the remaining 50 patients, the right ostium was located above the left in 37 patients. On the right, the angle of origin varied from -10 to + 55 (mean + 24 ). On the left, the angle of origin varied from + 30 to -55 (mean -11 ). Spiral CT angiography provides additional anatomic data, notably regarding the angle of origin of the renal arteries, that is potentially useful for planning interventional procedures. (orig.)

  10. Anatomical approach for surgery of the male posterior urethra.

    Science.gov (United States)

    Dalpiaz, Orietta; Mitterberger, Michael; Kerschbaumer, Andrea; Pinggera, Germar M; Bartsch, Georg; Strasser, Hannes

    2008-11-01

    To investigate, in a morphological study, the anatomy of the male rhabdosphincter and the relation between the membranous urethra, the rhabdosphincter and the neurovascular bundles (NVBs) to provide the anatomical basis for surgical approach of the posterior urethra as successful outcomes in urethral reconstructive surgery still remain a challenging issue. In all, 11 complete pelves and four tissue blocks of prostate, rectum, membranous urethra and the rhabdosphincter were studied. Besides anatomical preparations, the posterior urethra and their relationship were studied by means of serial histological sections. In the histological cross-sections, the rhabdosphincter forms an omega-shaped loop around the anterior and lateral aspects of the membranous urethra. Ventrally and laterally, it is separated from the membranous urethra by a delicate sheath of connective tissue. Through a midline approach displacing the nerves and vessels laterally, injuries to the NVBs can be avoided. With meticulous dissection of the delicate ventral connective tissue sheath between the ventral wall of the membranous urethra and the rhabdosphincter, the two structures can be separated without damage to either of them. This anatomical approach can be used for dissection of the anterior urethral wall in urethral surgery. Based on precise anatomical knowledge, the ventral wall of the posterior urethra can be dissected and exposed without injuring the rhabdosphincter and the NVBs. This approach provides the basis for sparing of the rhabdosphincter and for successful outcomes in urethral surgery for the treatment of bulbo-membranous urethral strictures.

  11. Laparoscopic sacrocolpopexy with bone anchor fixation: short-term anatomic and functional results.

    NARCIS (Netherlands)

    Withagen, M.I.J.; Vierhout, M.E.; Mannaerts, G.H.; Weiden, R.M.F. van der

    2012-01-01

    INTRODUCTION AND HYPOTHESIS: The aim of this study was to evaluate short-term anatomic and functional outcomes and safety of laparoscopic sacrocolpopexy with bone anchor fixation. METHODS: A prospective cohort study of women undergoing laparoscopic sacrocolpopexy between 2004 and 2009. Anatomic

  12. Anatomical variations of paranasal sinuses at multislice computed tomography: what to look for

    International Nuclear Information System (INIS)

    Miranda, Christiana Maia Nobre Rocha de; Maranhao, Carol Pontes de Miranda; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Jatoba, Mayara Stephanie de Araujo; Andrade, Anna Carolina Mendonca de; Padilha, Bruno Gomes

    2011-01-01

    Multislice computed tomography is currently the imaging modality of choice for evaluating paranasal sinuses and adjacent structures. Such a method has been increasingly utilized in the assessment of anatomical variations, allowing their accurate identification with high anatomical details. Some anatomical variations may predispose to sinusal diseases, constituting areas of high risk for injuries and complications during surgical procedures. Therefore, the recognition of such variations is critical in the preoperative evaluation for endoscopic surgery. (author)

  13. Anatomical variations of paranasal sinuses at multislice computed tomography: what to look for

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Christiana Maia Nobre Rocha de; Maranhao, Carol Pontes de Miranda [Clinica de Medicina Nuclear e Radiologia de Maceio (Medradius), Maceio, AL (Brazil). Setor de Tomografia Computadorizada; Arraes, Fabiana Maia Nobre Rocha [Clinica Sinus, Maceio, AL (Brazil); Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Jatoba, Mayara Stephanie de Araujo; Andrade, Anna Carolina Mendonca de; Padilha, Bruno Gomes [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil)

    2011-07-15

    Multislice computed tomography is currently the imaging modality of choice for evaluating paranasal sinuses and adjacent structures. Such a method has been increasingly utilized in the assessment of anatomical variations, allowing their accurate identification with high anatomical details. Some anatomical variations may predispose to sinusal diseases, constituting areas of high risk for injuries and complications during surgical procedures. Therefore, the recognition of such variations is critical in the preoperative evaluation for endoscopic surgery. (author)

  14. The Effect of Information Analysis Automation Display Content on Human Judgment Performance in Noisy Environments

    OpenAIRE

    Bass, Ellen J.; Baumgart, Leigh A.; Shepley, Kathryn Klein

    2012-01-01

    Displaying both the strategy that information analysis automation employs to makes its judgments and variability in the task environment may improve human judgment performance, especially in cases where this variability impacts the judgment performance of the information analysis automation. This work investigated the contribution of providing either information analysis automation strategy information, task environment information, or both, on human judgment performance in a domain where noi...

  15. Assessment of Anatomical Knowledge and Core Trauma Competency Vascular Skills.

    Science.gov (United States)

    Granite, Guinevere; Pugh, Kristy; Chen, Hegang; Longinaker, Nyaradzo; Garofalo, Evan; Shackelford, Stacy; Shalin, Valerie; Puche, Adam; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin

    2018-03-01

    Surgical residents express confidence in performing specific vascular exposures before training, but such self-reported confidence did not correlate with co-located evaluator ratings. This study reports residents' self-confidence evaluated before and after Advanced Surgical Skills for Exposure in Trauma (ASSET) cadaver-based training, and 12-18 mo later. We hypothesize that residents will better judge their own skill after ASSET than before when compared with evaluator ratings. Forty PGY2-7 surgical residents performed four procedures: axillary artery (AA), brachial artery (BA), femoral artery exposure and control (FA), and lower extremity fasciotomy (FAS) at the three evaluations. Using 5-point Likert scales, surgeons self-assessed their confidence in anatomical understanding and procedure performance after each procedure and evaluators rated each surgeon accordingly. For all the three evaluations, residents consistently rated their anatomical understanding (p < 0.04) and surgical performance (p < 0.03) higher than evaluators for both FA and FAS. Residents rated their anatomical understanding and surgical performance higher (p < 0.005) than evaluators for BA after training and up to 18 mo later. Only for third AA evaluation were there no rating differences. Residents overrate their anatomical understanding and performance abilities for BA, FA, and FAS even after performing the procedures and being debriefed three times in 18 mo.

  16. A novel anti-alpha-fetoprotein single-chain variable fragment displays anti-tumor effects in HepG2 cells as a single agent or in combination with paclitaxel.

    Science.gov (United States)

    Ji, Xiaonan; Shen, Yanli; Sun, Hao; Gao, Xiangdong

    2016-08-01

    Human hepatocellular carcinoma (HCC) has a high rate of tumor recurrence and metastasis, resulting in shortened survival time. The function of alpha-fetoprotein (AFP) as a regulatory factor in the growth of HCC cells has been well defined. The aim of this study was to investigate the use of a novel AFP-specific single-chain variable fragment that blocked AFP and inhibited HCC cell growth. The results indicated that the anti-AFP single-chain variable fragment (scFv) induced growth inhibition of AFP-expressing HCC cell lines in vitro through induction of G1 cell cycle arrest and apoptosis. The mechanism of apoptosis probably involved with blocking AFP internalization and regulation of the PTEN/PI3K/Akt signaling network. Moreover, the anti-AFP-scFv also effectively sensitized the HepG2 cells to paclitaxel (PTX) at a lower concentration. The combination effect of PTX and anti-AFP-scFv displayed a synergistic effect on HepG2 cells both in vitro and in vivo. Our results demonstrated that targeting AFP by specific antibodies has potential immunotherapeutic efficacy in human HCC.

  17. Display of adenoregulin with a novel Pichia pastoris cell surface display system.

    Science.gov (United States)

    Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi

    2007-02-01

    Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.

  18. Efficacy of an Intra-Operative Imaging Software System for Anatomic Anterior Cruciate Ligament Reconstruction Surgery

    Directory of Open Access Journals (Sweden)

    Xudong Zhang

    2012-01-01

    Full Text Available An imaging software system was studied for improving the performance of anatomic anterior cruciate ligament (ACL reconstruction which requires identifying ACL insertion sites for bone tunnel placement. This software predicts and displays the insertion sites based on the literature data and patient-specific bony landmarks. Twenty orthopaedic surgeons performed simulated arthroscopic ACL surgeries on 20 knee specimens, first without and then with the visual guidance by fluoroscopic imaging, and their tunnel entry positions were recorded. The native ACL insertion morphologies of individual specimens were quantified in relation to CT-based bone models and then used to evaluate the software-generated insertion locations. Results suggested that the system was effective in leading surgeons to predetermined locations while the application of averaged insertion morphological information in individual surgeries can be susceptible to inaccuracy and uncertainty. Implications on challenges associated with developing engineering solutions to aid in re-creating or recognizing anatomy in surgical care delivery are discussed.

  19. Ultrasound of the rotator cuff with MRI and anatomic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Rutten, Matthieu J.C.M. [Department of Radiology, Jeroen Bosch Hospital, Nieuwstraat 34, 5211 NL ' s-Hertogenbosch (Netherlands)]. E-mail: M.Rutten@JBZ.nl; Maresch, Bas J. [Department of Radiology, Hospital Gelderse Vallei, Willy Brandtlaan 10, 6710 HN Ede (Netherlands)]. E-mail: MareschB@zgv.nl; Jager, Gerrit J. [Department of Radiology, Jeroen Bosch Hospital, Nieuwstraat 34, 5211 NL ' s-Hertogenbosch (Netherlands)]. E-mail: G.Jager@JBZ.nl; Blickman, Johan G. [Department of Radiology, University Medical Center Nijmegen, Geert Grooteplein Zuid 18, 6500 HB Nijmegen (Netherlands)]. E-mail: J.Blickman@rad.umcn.nl; Holsbeeck, Marnix T. van [Department of Radiology, Henry Ford Hospital, 2799 W Grand Boulevard, Detroit, MI 48202 (United States)]. E-mail: vanholsbeeck@comcast.net

    2007-06-15

    Magnetic resonance imaging and high-resolution ultrasound (US) are frequently used for the detection of rotator cuff tears. The diagnostic yield of US is influenced by several factors as technique, knowledge of the imaging characteristics of anatomic and pathologic findings and of pitfalls. The purpose of this article is to illustrates that the standardized high-resolution US examination of the shoulder covers the entire rotator cuff and correlates with MR imaging and anatomic sections.

  20. The maxillary second molar - anatomical variations (case report).

    Science.gov (United States)

    Beshkenadze, E; Chipashvili, N

    2015-01-01

    To be acquainted with dental anatomical specificity is of great importance for dental endodontic treatment algorithm. The subject of present publication is 2 clinical cases of upper second molars, detailed characterization of, which is considered very important for enrichment of anatomical knowledge about dental anatomical variations. In one case, the reason for admission to the clinic of a 38-year-old woman was complains as of esthetic character as well as functional misbalance (disturbance of chewing function due to the damage of orthopedic construction). The patient indicated to the existence of coronary defects of large size aesthetic discomforts, damage and discolouration of old orthopedic construction (denture) in maxillary right molar area. According to the data obtained after clinical and visiographical examinations, chronic periodontitis of 17 teeth was identified as a result of incomplete endodontic treatment. According to the data obtained after clinical and visiographical examinations, the diagnosis of chronic periodontitis of 17 teeth was identified, tooth 17 with 2 roots and 2 canals. In the second clinical case, the reason for admission to the clinic of a 39-year-old woman was severe pain in the upper right molar area. The patient indicated to the caries on the tooth 17. After completion of proper survey clinical and visiographical examinations, acute pulpitis (K04.00) - with three roots and 4 canals was diagnosed. In both cases after the proper examinations and agreement with the patients a treatment plan envisaging: 17 teeth endodontic treatment, filling of caries defects and their preparation on one hand for orthopedic construction (denture) and on the other hand for restoration of anatomical integrity by light-cured composite, was scheduled. The present study is designed to prevent complications of endodontic treatment of the second molar, to optimize diagnosis and treatment algorithm, once again proving reliable information indicating to the

  1. Development of a visual control and display system for the SMART plant analyzer

    International Nuclear Information System (INIS)

    Kang, Han Ok; Yoon, Ju Hyeon; Seo, Jae Kwang; Lee, Doo Jeong

    2000-01-01

    A Visual Control and Display System (VCDS) for the SMART plant analyzer has been developed using the MMS simulation tools. The SAMRT plant analyzer consists of the VCDS and the MMS SMART model. The MMS SMART model is a numerical simulation model for the SMART plant and is composed of the MMS real-time modules and control blocks. It covers the whole plant including primary, secondary and auxiliary systems. The developed VCDS is Graphical User Interfaces (GUI) that is running in a synchronized way with the SMART model. The VCDS consists of the MMS Simulation tools and seven control and display screens. The VCDS provides easy means for the control and display of the SMART model status. The VCDS allows users to display and change a specified list of model variables and transient scenarios interactively through the MMS simulation tools. The control and display screens are developed with Visual Basic 6.0 and MMI32 ActiveX controls and it can be executed in several TCP/IP networked computers simultaneously. The developed VCDS can be utilized for the engineering simulation of the SMART plant operation, and for control logic and operational procedure developments

  2. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  3. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  4. Handbook of Visual Display Technology

    CERN Document Server

    Cranton, Wayne; Fihn, Mark

    2012-01-01

    The Handbook of Visual Display Technology is a unique work offering a comprehensive description of the science, technology, economic and human interface factors associated with the displays industry. An invaluable compilation of information, the Handbook will serve as a single reference source with expert contributions from over 150 international display professionals and academic researchers. All classes of display device are covered including LCDs, reflective displays, flexible solutions and emissive devices such as OLEDs and plasma displays, with discussion of established principles, emergent technologies, and particular areas of application. The wide-ranging content also encompasses the fundamental science of light and vision, image manipulation, core materials and processing techniques, display driving and metrology.

  5. Polymer Dispersed Liquid Crystal Displays

    Science.gov (United States)

    Doane, J. William

    The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES

  6. Information rich display design

    International Nuclear Information System (INIS)

    Welch, Robin; Braseth, Alf Ove; Veland, Oeystein

    2004-01-01

    This paper presents the concept Information Rich Displays. The purpose of Information Rich Displays (IRDs) is to condensate prevailing information in process displays in such a way that each display format (picture) contains more relevant information for the user. Compared to traditional process control displays, this new concept allows the operator to attain key information at a glance and at the same time allows for improved monitoring of larger portions of the process. This again allows for reduced navigation between both process and trend displays and ease the cognitive demand on the operator. This concept has been created while working on designing display prototypes for the offshore petroleum production facilities of tomorrow. Offshore installations basically consist of wells, separation trains (where oil, gas and water are separated from each other), an oil tax measurement system (where oil quality is measured and the pressure increased to allow for export), gas compression (compression of gas for export) and utility systems (water treatment, chemical systems etc.). This means that an offshore control room operator has to deal with a complex process that comprises several functionally different systems. The need for a new approach to offshore display format design is in particular based on shortcomings in today's designs related to the keyhole effect, where the display format only reveals a fraction of the whole process. Furthermore, the upcoming introduction of larger off- and on-shore operation centres will increase the size and complexity of the operators' work domain. In the light of the increased demands on the operator, the proposed IRDs aim to counter the negative effects this may have on the workload. In this work we have attempted to classify the wide range of different roles an operator can have in different situations. The information content and amount being presented to the operator in a display should be viewed in context of the roles the

  7. Patellar calcar: MRI appearance of a previously undescribed anatomical entity

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Mark S.; Tiegs-Heiden, Christin A. [Department of Radiology, Mayo Clinic, Rochester, Minnesota (United States); Stuart, Michael J. [Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota (United States)

    2014-02-15

    The femoral calcar is a constant anatomical structure within the proximal femur representing a condensation of bone trabeculae. It is our impression that a similar structure is present within the patella. The purpose of this retrospective study was to define the prevalence, appearance, location, and configuration of the patellar calcar on MRI examinations. One hundred consecutive unenhanced knee MRIs were retrospectively reviewed by two readers who were blinded to the clinical indication. The patellar calcar was defined as a dark signaling, linear or curvilinear structure subjacent to the patellar articular surface. If present, the patellar calcar was assigned to a ''well seen,'' ''moderately well seen,'' or ''faintly seen'' category. Location of the calcar within the patella, orientation, configuration, and thickness were recorded. Confounding variables, such as marrow edema, patellar chondromalacia, bipartite patella, or postoperative changes were also recorded. The patellar calcar was visualized in 81 out of 100 (81 %) MRIs. When detected, the calcar was well seen in 20 out of 81 (25 %), moderately well seen in 35 out of 81 (43 %), and faintly seen in 26 out of 81 (32 %). The anteroposterior width of the calcar measured at its thickest segment was: < 1 mm in 43 out of 81 (53 %), 1 mm in 28 out of 81 (35 %), and >1 mm in 10 out of 81 (12 %). The patellar calcar was seen in the majority of knee MRIs and had a consistent imaging appearance. The calcar may be obscured by degenerative arthrosis of the patella and rarely may mimic patellar stress fracture or osteochondritis dissecans. Radiologists and clinicians should be familiar with this normal anatomical structure. (orig.)

  8. Chemical and anatomical changes in Liquidambar styraciflua L. xylem after long term exposure to elevated CO2

    International Nuclear Information System (INIS)

    Kim, Keonhee; Labbé, Nicole; Warren, Jeffrey M.; Elder, Thomas; Rials, Timothy G.

    2015-01-01

    The anatomical and chemical characteristics of sweetgum were studied after 11 years of elevated CO 2 (544 ppm, ambient at 391 ppm) exposure. Anatomically, branch xylem cells were larger for elevated CO 2 trees, and the cell wall thickness was thinner. Chemically, elevated CO 2 exposure did not impact the structural components of the stem wood, but non-structural components were significantly affected. Principal component analysis (PCA) was employed to detect differences between the CO 2 treatments by considering numerous structural and chemical variables, as well as tree size, and data from previously published sources (i.e., root biomass, production and turnover). The PCA results indicated a clear separation between trees exposed to ambient and elevated CO 2 conditions. Correlation loadings plots of the PCA revealed that stem structural components, ash, Ca, Mg, total phenolics, root biomass, production and turnover were the major responses that contribute to the separation between the elevated and ambient CO 2 treated trees. - Highlights: • First study of wood properties after 11 years of higher level of CO 2 treatment. • Elevated CO 2 exposure does not impact structural components of wood. • Total phenolics content and some inorganics were significantly affected. • Branch xylem cells were larger under elevated CO 2 . • Cell wall thickness was thinner under elevated CO 2 . - Elevated CO 2 in atmosphere did not impact the structural components yet altered some of non-structural components and anatomical properties after 11 years of exposure on sweetgum

  9. Estimating anatomical wrist joint motion with a robotic exoskeleton.

    Science.gov (United States)

    Rose, Chad G; Kann, Claudia K; Deshpande, Ashish D; O'Malley, Marcia K

    2017-07-01

    Robotic exoskeletons can provide the high intensity, long duration targeted therapeutic interventions required for regaining motor function lost as a result of neurological injury. Quantitative measurements by exoskeletons have been proposed as measures of rehabilitative outcomes. Exoskeletons, in contrast to end effector designs, have the potential to provide a direct mapping between human and robot joints. This mapping rests on the assumption that anatomical axes and robot axes are aligned well, and that movement within the exoskeleton is negligible. These assumptions hold well for simple one degree-of-freedom joints, but may not be valid for multi-articular joints with unique musculoskeletal properties such as the wrist. This paper presents an experiment comparing robot joint kinematic measurements from an exoskeleton to anatomical joint angles measured with a motion capture system. Joint-space position measurements and task-space smoothness metrics were compared between the two measurement modalities. The experimental results quantify the error between joint-level position measurements, and show that exoskeleton kinematic measurements preserve smoothness characteristics found in anatomical measures of wrist movements.

  10. Anatomical Terms in J. Basanavičius’ Manuscript Anatomijos ir medicinos vardyno medžiaga

    Directory of Open Access Journals (Sweden)

    Nijolė Litevkienė

    2011-12-01

    Full Text Available The historical evolution of anatomical terms dates to antiquity, to the writings of Hippocrates. The historical development of Lithuanian anatomical terminology goes back to the seventeenth century. Anatomical terminology, as a comprehensive system of the names of human body parts is being compiled gradually. The originator of Lithuanian medical terminology was J. Basanavičius. The research paper aims to analyze anatomical terms used in J. Basanavičius’ manuscript Anatomijos ir medicinos vardyno medžiaga (further BM and to compare them with the terms in the Dictionary of Medical Terms ( Medicinos terminų žodynas 1980. The research focuses on the analysis of some aspects of differentiation and congruity of simple and multi-word anatomical terms of the manuscript and the dictionary. About 270 Lithuanian anatomical terms with Russian and Latin equivalents were collected by J. Basanavičius. The results show that the major part of the terms are different, the lesser part of the terms are identical.

  11. Development of a patient-specific anatomical foot model from structured light scan data.

    Science.gov (United States)

    Lochner, Samuel J; Huissoon, Jan P; Bedi, Sanjeev S

    2014-01-01

    The use of anatomically accurate finite element (FE) models of the human foot in research studies has increased rapidly in recent years. Uses for FE foot models include advancing knowledge of orthotic design, shoe design, ankle-foot orthoses, pathomechanics, locomotion, plantar pressure, tissue mechanics, plantar fasciitis, joint stress and surgical interventions. Similar applications but for clinical use on a per-patient basis would also be on the rise if it were not for the high costs associated with developing patient-specific anatomical foot models. High costs arise primarily from the expense and challenges of acquiring anatomical data via magnetic resonance imaging (MRI) or computed tomography (CT) and reconstructing the three-dimensional models. The proposed solution morphs detailed anatomy from skin surface geometry and anatomical landmarks of a generic foot model (developed from CT or MRI) to surface geometry and anatomical landmarks acquired from an inexpensive structured light scan of a foot. The method yields a patient-specific anatomical foot model at a fraction of the cost of standard methods. Average error for bone surfaces was 2.53 mm for the six experiments completed. Highest accuracy occurred in the mid-foot and lowest in the forefoot due to the small, irregular bones of the toes. The method must be validated in the intended application to determine if the resulting errors are acceptable.

  12. Advertising cadavers in the republic of letters: anatomical publications in the early modern Netherlands.

    Science.gov (United States)

    Margócsy, Dániel

    2009-06-01

    This paper sketches how late seventeenth-century Dutch anatomists used printed publications to advertise their anatomical preparations, inventions and instructional technologies to an international clientele. It focuses on anatomists Frederik Ruysch (1638-1732) and Lodewijk de Bils (1624-69), inventors of two separate anatomical preparation methods for preserving cadavers and body parts in a lifelike state for decades or centuries. Ruysch's and de Bils's publications functioned as an 'advertisement' for their preparations. These printed volumes informed potential customers that anatomical preparations were aesthetically pleasing and scientifically important but did not divulge the trade secrets of the method of production. Thanks to this strategy of non-disclosure and advertisement, de Bils and Ruysch could create a well-working monopoly market of anatomical preparations. The 'advertising' rhetorics of anatomical publications highlight the potential dangers of equating the growth of print culture with the development of an open system of knowledge exchange.

  13. Report of a rare anatomic variant

    DEFF Research Database (Denmark)

    De Brucker, Y; Ilsen, B; Muylaert, C

    2015-01-01

    We report the CT findings in a case of partial anomalous pulmonary venous return (PAPVR) from the left upper lobe in an adult. PAPVR is an anatomic variant in which one to three pulmonary veins drain into the right atrium or its tributaries, rather than into the left atrium. This results in a left...

  14. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  15. A study of biceps brachii muscle: Anatomical considerations and clinical implications

    Directory of Open Access Journals (Sweden)

    Vaishaly Kishore Bharambe

    2015-01-01

    Full Text Available Context: Biceps brachii muscle (BBm is a very variable muscle, the variations being associated with a variety of clinical conditions. This study delves on anatomical variations in this muscle, possible phylogenic causes for their frequency and their clinical importance. Aims: The aim was to study anatomy of bicep brachii muscle, its variations and their clinical importance. Subjects and Methods: A total of 60 upper limbs preserved in 10% formalin were dissected meticulously to study anatomical details of the BBm. Results: The incidence of variation in anatomy of BBm was 15%, with incidence being 11.6% and 3.3% among male and female cadavers studied, respectively. Variation was unilateral in 10% and bilateral in 3.3%. The incidence of third head was 13.3% out of which 3.3% took origin from the capsule of the shoulder joint, 8.3% from humerus, and 1.6% from brachialis muscle. Incidence of extra bellies of insertion was found to be 1.6%. A 3.3% incidence was observed in the nerve supply. Conclusions: Variations in BBm are a reflection of its late development in human phylum. The extra bellies can cause neurovascular compression, change the kinematics at the elbow joint and be misinterpreted as tears of muscle on magnetic resonance imaging. They should be watched for in the shoulder as well as elbow joint surgeries. The authors suggest that the extra bellies of BBm instead of being labeled as third, fourth or fifth heads, can be classified as those of origin and insertion and bellies of origin be referred to clearly as capsular, humeral or brachial heads.

  16. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  17. Display technologies for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  18. Nodule detection in digital chest radiography: Effect of anatomical noise

    International Nuclear Information System (INIS)

    Baath, M.; Haakansson, M.; Boerjesson, S.; Hoeschen, C.; Tischenko, O.; Kheddache, S.; Vikgren, J.; Maansson, L. G.

    2005-01-01

    The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (referred to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high delectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions). (authors)

  19. Mobilization of the rectum: anatomic concepts and the bookshelf revisited.

    Science.gov (United States)

    Chapuis, Pierre; Bokey, Les; Fahrer, Marius; Sinclair, Gael; Bogduk, Nikolai

    2002-01-01

    Sound surgical technique is based on accurate anatomic knowledge. In surgery for cancer, the anatomy of the perirectal fascia and the retrorectal plane is the basis for correct mobilization of the rectum to ensure clear surgical margins and to minimize the risk of local recurrence. This review of the literature on the perirectal fascia is based on a translation of the original description by Thoma Jonnesco and a later account by Wilhelm Waldeyer. The Jonnesco description, first published in 1896 in French, is compared with the German account of 1899. These were critically analyzed in the context of our own and other techniques of mobilizing the rectum. Mobilization of the rectum for cancer can be performed along anatomic planes with minimal blood loss, preservation of the pelvic autonomic nerves and a low prevalence of local recurrence. Different techniques including total mesorectal excision are based on the same anatomic principles, however, popular words have been used to replace accepted, established terminology. In particular, the description of total mesorectal excision has been confusing because of its emphasis on the words "total" and "mesorectum." The use of the word "mesorectum" anatomically is inaccurate and the implication that total excision of all the perirectal fat contained within the perirectal fascia "en bloc" in all patients with rectal cancer will minimize local recurrence remains contentious.

  20. Prevalence of anatomical variations in maxillary sinus using cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Deepjyoti K Mudgade

    2018-01-01

    Full Text Available Introduction: The maxillary sinuses (MS are of particular importance to dentist because of their close proximity to the teeth and their associated structures, so increased risk of maxillary sinusitis has been reported with periapical abscess, periodontal diseases, dental trauma, tooth extraction, and implant placement. Complications of MS are related to its anatomic and pathologic variations. Thus, study was conducted to assess the prevalence of anatomic variations in MS by using cone-beam computerized tomography (CBCT. Aims and Objectives: To determine different anatomical variations in MS by using CBCT. Materials and Methods: CBCT scans of 150 subjects were collected between the age group of 18 years to 70 years and were analyzed for MS anatomical variation. Statistical Analysis: The distribution of age, sex, reasons for CBCT, and dimensions of sinus calculated using descriptive statistics and distribution of other anatomic findings using Chi-square test. Results: Prevalence of obstructed ostium is 23.3% and septa is 66.7%. Average height, width, and antero-posterior (A-P dimensions for right MS are 34.13 mm, 26.09 mm, 37.39 mm and that of left MS are 33.24 mm, 26.11 mm, 37.72 mm respectively. Average distance between lower border of ostium to sinus floor in right MS is 32.17 mm and that of left is 32.69 mm. Average diameter of ostium in right MS is 1.88 mm and that of left is 1.67 mm. Conclusion: Study highlights the importance of accurate assessment of MS and its variations in order to properly differentiate the pathologic lesions from anatomic variations avoiding unnecessary surgical explorations.

  1. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  2. Magnetic resonance angiography: infrequent anatomic variants

    International Nuclear Information System (INIS)

    Trejo, Mariano; Meli, Francisco; Lambre, Hector; Blessing, Ricardo; Gigy Traynor, Ignacio; Miguez, Victor

    2002-01-01

    We studied through RM angiography (3D TOF) with high magnetic field equipment (1.5 T) different infrequent intracerebral vascular anatomic variants. For their detection we emphasise the value of post-processed images obtained after conventional angiographic sequences. These post-processed images should be included in routine protocols for evaluation of the intracerebral vascular structures. (author)

  3. Anatomical characteristics of southern pine stemwood

    Science.gov (United States)

    Elaine T. Howard; Floyd G. Manwiller

    1968-01-01

    To obtain a definitive description of the wood and anatomy of all 10 species of southern pine, juvenile, intermediate, and mature wood was sampled at three heights in one tree of each species and examined under a light microscope. Photographs and three-dimensional drawings were made to illustrate the morphology. No significant anatomical differences were found...

  4. HPV Vaccine Effective at Multiple Anatomic Sites

    Science.gov (United States)

    A new study from NCI researchers finds that the HPV vaccine protects young women from infection with high-risk HPV types at the three primary anatomic sites where persistent HPV infections can cause cancer. The multi-site protection also was observed at l

  5. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  6. Evaluating Approaches to Rendering Braille Text on a High-Density Pin Display.

    Science.gov (United States)

    Morash, Valerie S; Russomanno, Alexander; Gillespie, R Brent; OModhrain, Sile

    2017-10-13

    Refreshable displays for tactile graphics are typically composed of pins that have smaller diameters and spacing than standard braille dots. We investigated configurations of high-density pins to form braille text on such displays using non-refreshable stimuli produced with a 3D printer. Normal dot braille (diameter 1.5 mm) was compared to high-density dot braille (diameter 0.75 mm) wherein each normal dot was rendered by high-density simulated pins alone or in a cluster of pins configured in a diamond, X, or square; and to "blobs" that could result from covering normal braille and high-density multi-pin configurations with a thin membrane. Twelve blind participants read MNREAD sentences displayed in these conditions. For high-density simulated pins, single pins were as quickly and easily read as normal braille, but diamond, X, and square multi-pin configurations were slower and/or harder to read than normal braille. We therefore conclude that as long as center-to-center dot spacing and dot placement is maintained, the dot diameter may be open to variability for rendering braille on a high density tactile display.

  7. Passive method of eliminating accommodation/convergence disparity in stereoscopic head-mounted displays

    Science.gov (United States)

    Eichenlaub, Jesse B.

    2005-03-01

    The difference in accommodation and convergence distance experienced when viewing stereoscopic displays has long been recognized as a source of visual discomfort. It is especially problematic in head mounted virtual reality and enhanced reality displays, where images must often be displayed across a large depth range or superimposed on real objects. DTI has demonstrated a novel method of creating stereoscopic images in which the focus and fixation distances are closely matched for all parts of the scene from close distances to infinity. The method is passive in the sense that it does not rely on eye tracking, moving parts, variable focus optics, vibrating optics, or feedback loops. The method uses a rapidly changing illumination pattern in combination with a high speed microdisplay to create cones of light that converge at different distances to form the voxels of a high resolution space filling image. A bench model display was built and a series of visual tests were performed in order to demonstrate the concept and investigate both its capabilities and limitations. Results proved conclusively that real optical images were being formed and that observers had to change their focus to read text or see objects at different distances

  8. Anatomic variations of the cerebral arteries and their embryology: a pictorial review

    International Nuclear Information System (INIS)

    Okahara, Mika; Kiyosue, Hiro; Mori, Hiromu; Tanoue, Shuichi; Sainou, Michihumi; Nagatomi, Hirohumi

    2002-01-01

    In the embryonic period, several developmental anomalies of the cerebral arteries occur. The knowledge of these anatomic variations of the cerebral artery is important to avoid the unnecessary surgery and to undergo surgery or interventional radiology with safety. We reviewed 3000 MR angiographies and 700 cerebral angiographies of the previous 5 years to assess cerebral arterial system, and to illustrate the embryological development, imaging findings, occurrence, and clinical significance of the anatomic variation of the cerebral arteries. The normal development and variations of the cerebral arteries are depicted. Knowledge of the anatomic variations is important since it can influence surgical and interventional procedure. (orig.)

  9. Corona mortis: an anatomical variation with clinical relevance. Case report.

    Directory of Open Access Journals (Sweden)

    Guillermo Adrián Rivera-Cardona

    2010-12-01

    Full Text Available The obturator artery is one of the parietal branches arising from the internal iliac artery, the anatomical variation from which this artery originates is called “The corona mortis”, generally from the external iliac artery or the inferior epigastric artery. This finding was observed bilaterally in a male cadaver during a pelvis dissection. Clinical consideration of the anatomical variation in the obturator artery, during surgical procedures, is of great importance due to the risk of pelvic hemorrhage.

  10. MORPHOLOGICAL AND ANATOMICAL STUDY ON ENDEMIC CROCUS OLIVIERI GAY SUBSP. ISTANBULENSIS MATHEW SUBSPECIES (IRIDACEAE

    Directory of Open Access Journals (Sweden)

    Kadriye Yetişen

    2013-02-01

    Full Text Available In this study, morphological and anatomical properties of Crocus olivieri Gay subsp. istanbulensis Mathew were investigated. Cross-sections of root, scape and leaf parts of the plant were examined anddemonstrated by photographs. Most of the anatomical properties are similar to the other member of Iridaceae family. Sclerenchyma groups were observed around to leaf vascular bundle. Morphological and anatomical findings compared with other two subspecies of Crocus olivieri.

  11. Segmentation of medical images using explicit anatomical knowledge

    Science.gov (United States)

    Wilson, Laurie S.; Brown, Stephen; Brown, Matthew S.; Young, Jeanne; Li, Rongxin; Luo, Suhuai; Brandt, Lee

    1999-07-01

    Knowledge-based image segmentation is defined in terms of the separation of image analysis procedures and representation of knowledge. Such architecture is particularly suitable for medical image segmentation, because of the large amount of structured domain knowledge. A general methodology for the application of knowledge-based methods to medical image segmentation is described. This includes frames for knowledge representation, fuzzy logic for anatomical variations, and a strategy for determining the order of segmentation from the modal specification. This method has been applied to three separate problems, 3D thoracic CT, chest X-rays and CT angiography. The application of the same methodology to such a range of applications suggests a major role in medical imaging for segmentation methods incorporating representation of anatomical knowledge.

  12. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  13. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  14. An application of the process computer and CRT display system in BWR nuclear power station

    International Nuclear Information System (INIS)

    Goto, Seiichiro; Aoki, Retsu; Kawahara, Haruo; Sato, Takahisa

    1975-01-01

    A color CRT display system was combined with a process computer in some BWR nuclear power plants in Japan. Although the present control system uses the CRT display system only as an output device of the process computer, it has various advantages over conventional control panel as an efficient plant-operator interface. Various graphic displays are classified into four categories. The first is operational guide which includes the display of control rod worth minimizer and that of rod block monitor. The second is the display of the results of core performance calculation which include axial and radial distributions of power output, exit quality, channel flow rate, CHFR (critical heat flux ratio), FLPD (fraction of linear power density), etc. The third is the display of process variables and corresponding computational values. The readings of LPRM, control rod position and the process data concerning turbines and feed water system are included in this category. The fourth category includes the differential axial power distribution between base power distribution (obtained from TIP) and the reading of each LPRM detector, and the display of various input parameters being used by the process computer. Many photographs are presented to show examples of those applications. (Aoki, K.)

  15. A practical workflow for making anatomical atlases for biological research.

    Science.gov (United States)

    Wan, Yong; Lewis, A Kelsey; Colasanto, Mary; van Langeveld, Mark; Kardon, Gabrielle; Hansen, Charles

    2012-01-01

    The anatomical atlas has been at the intersection of science and art for centuries. These atlases are essential to biological research, but high-quality atlases are often scarce. Recent advances in imaging technology have made high-quality 3D atlases possible. However, until now there has been a lack of practical workflows using standard tools to generate atlases from images of biological samples. With certain adaptations, CG artists' workflow and tools, traditionally used in the film industry, are practical for building high-quality biological atlases. Researchers have developed a workflow for generating a 3D anatomical atlas using accessible artists' tools. They used this workflow to build a mouse limb atlas for studying the musculoskeletal system's development. This research aims to raise the awareness of using artists' tools in scientific research and promote interdisciplinary collaborations between artists and scientists. This video (http://youtu.be/g61C-nia9ms) demonstrates a workflow for creating an anatomical atlas.

  16. Anatomical characteristics of Turkish steno-endemic Origanum leptocladum Boiss. (Lamiaceae

    Directory of Open Access Journals (Sweden)

    Süleyman Doğu

    2013-04-01

    Full Text Available Origanum leptocladum Boiss. is an endemic East Mediterranean element, naturally growing only in Ermenek district of Karaman province in Turkey. The aim of this study is to determine anatomical features of the species. The study materials were collected from Karaman-Ermenek in 2009 and then preserved in 70 % alcohol. O. leptocladum generally exhibits the anatomical feaures of the family Lamiaceae. Hovewer, herbaceaus stem is weakly-rectangle shaped or tends to be circular, the collenchymatic tissue at the corner of the stem and scleranchymatic pericycle around the vascular tissue are weakly-developed. The most striking anatomical feature is that leaf lamina is dorsiventral in the region near to midvein, but equifacial out of the midvein. According to the results, while the stomata are of mesomorphic type on the leaf surfaces, O. leptocladum has xeromorphic characters such as palisade richness in mesophyll, the occurrence of rich scleranchymatic tissue in midvein and cuticle thickness on leaf surface.

  17. Display systems for NPP control

    International Nuclear Information System (INIS)

    Rozov, S.S.

    1988-01-01

    Main trends in development of display systems used as the means for image displaying in NPP control systems are considered. It is shown that colour display devices appear to be the most universal means for concentrated data presentation. Along with digital means the display systems provide for high-speed response, sufficient for operative control of executive mechanisms. A conclusion is drawn that further development of display systems will move towards creation of large colour fields (on reflection base or with multicolour gas-discharge elements)

  18. Cell size and wall dimensions drive distinct variability of earlywood and latewood density in Northern Hemisphere conifers.

    Science.gov (United States)

    Björklund, Jesper; Seftigen, Kristina; Schweingruber, Fritz; Fonti, Patrick; von Arx, Georg; Bryukhanova, Marina V; Cuny, Henri E; Carrer, Marco; Castagneri, Daniele; Frank, David C

    2017-11-01

    Interannual variability of wood density - an important plant functional trait and environmental proxy - in conifers is poorly understood. We therefore explored the anatomical basis of density. We hypothesized that earlywood density is determined by tracheid size and latewood density by wall dimensions, reflecting their different functional tasks. To determine general patterns of variability, density parameters from 27 species and 349 sites across the Northern Hemisphere were correlated to tree-ring width parameters and local climate. We performed the same analyses with density and width derived from anatomical data comprising two species and eight sites. The contributions of tracheid size and wall dimensions to density were disentangled with sensitivity analyses. Notably, correlations between density and width shifted from negative to positive moving from earlywood to latewood. Temperature responses of density varied intraseasonally in strength and sign. The sensitivity analyses revealed tracheid size as the main determinant of earlywood density, while wall dimensions become more influential for latewood density. Our novel approach of integrating detailed anatomical data with large-scale tree-ring data allowed us to contribute to an improved understanding of interannual variations of conifer growth and to illustrate how conifers balance investments in the competing xylem functions of hydraulics and mechanical support. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  19. Anatomic humeral head replacement with a press-fit prosthesis: An in vivo radiographic study

    Directory of Open Access Journals (Sweden)

    Bryan Vopat

    2017-10-01

    Full Text Available Successful total shoulder arthroplasty is, in part, dependent on anatomic reconstruction of the glenohumeral joint. The purpose of this study was to evaluate the post-operative anatomy of total shoulder arthroplasty with an anatomic implant design in patients with primary glenohumeral osteoarthritis and compare it to published normative anatomic measurements. Fifty-one patients (56 shoulders with primary glenohumeral osteoarthritis were treated with a press-fit humeral component as part of a total shoulder arthroplasty (Aequalis, Tornier, Edina, Minnesota. Analysis of postoperative true anterior posterior radiographs was performed with use of a custom software algorithm. The mean humeral inclination (head-shaft angle, mean humeral implant anatomical humeral axis, mean greater tuberosity height, and mean humeral head center offset (medial offset were 135.4±5.1°, 1.73±1.7°, 6.9±2.4 mm, and 3.8±1.8 mm, respectively. All parameters were within the ranges reported in the literature for normal shoulders except the mean humeral head center offset, which was less than reported in the literature. Anatomic parameters of a total shoulder arthroplasty can be achieved with an anatomically designed, modular adaptable press-fit design. Reduced medial humeral head center offset was likely dependent upon implant specific design parameters.

  20. Dissimilarity-based classification of anatomical tree structures

    DEFF Research Database (Denmark)

    Sørensen, Lauge; Lo, Pechin Chien Pau; Dirksen, Asger

    2011-01-01

    A novel method for classification of abnormality in anatomical tree structures is presented. A tree is classified based on direct comparisons with other trees in a dissimilarity-based classification scheme. The pair-wise dissimilarity measure between two trees is based on a linear assignment betw...

  1. Dissimilarity-based classification of anatomical tree structures

    DEFF Research Database (Denmark)

    Sørensen, Lauge Emil Borch Laurs; Lo, Pechin Chien Pau; Dirksen, Asger

    2011-01-01

    A novel method for classification of abnormality in anatomical tree structures is presented. A tree is classified based on direct comparisons with other trees in a dissimilarity-based classification scheme. The pair-wise dissimilarity measure between two trees is based on a linear assignment...

  2. Variable acuity remote viewing system flight demonstration

    Science.gov (United States)

    Fisher, R. W.

    1983-01-01

    The Variable Acuity Remote Viewing System (VARVS), originally developed under contract to the Navy (ONR) as a laboratory brassboard, was modified for flight demonstration. The VARVS system was originally conceived as a technique which could circumvent the acuity/field of view/bandwidth tradeoffs that exists in remote viewing to provide a nearly eye limited display in both field of view (160 deg) and resolution (2 min arc) while utilizing conventional TV sensing, transmission, and display equipment. The modifications for flight demonstration consisted of modifying the sensor so it could be installed and flow in a Piper PA20 aircraft, equipped for remote control and modifying the display equipment so it could be integrated with the NASA Research RPB (RPRV) remote control cockpit.

  3. Anatomical characteristics of the ossa sesamoidea phalangis proximalis in cattle (Bos primigenius f. taurus Linné 1758)

    Energy Technology Data Exchange (ETDEWEB)

    Červený, Č. [Vysoka Skola Veterinarni, Brno, Czechoslovakia (Czech Republic)

    1985-06-15

    The anatomical structure and radiography of the sesamoid bones of the proximal phalanges of cattle digits were studied on osteological material and radiograms of 18 cows and 5 bulls. On the basis of detailed anatomical description, a list of new anatomical names for important anatomical formations was proposed in order to complete the anatomical nomenclature and to provide better orientation on the bones as well as a more precise description of the different bones and determine their origin from the respective digits and/or the left or right thoratic or pelvic limbs.

  4. Anatomical characteristics of the ossa sesamoidea phalangis proximalis in cattle (Bos primigenius f. taurus Linné 1758)

    International Nuclear Information System (INIS)

    Červený, Č.

    1985-01-01

    The anatomical structure and radiography of the sesamoid bones of the proximal phalanges of cattle digits were studied on osteological material and radiograms of 18 cows and 5 bulls. On the basis of detailed anatomical description, a list of new anatomical names for important anatomical formations was proposed in order to complete the anatomical nomenclature and to provide better orientation on the bones as well as a more precise description of the different bones and determine their origin from the respective digits and/or the left or right thoratic or pelvic limbs

  5. Shaping Tourist LL: Language Display and the Sociolinguistic Background of an International Multilingual Readership

    Science.gov (United States)

    Bruyèl-Olmedo, Antonio; Juan-Garau, Maria

    2015-01-01

    Linguistic landscape studies increasingly focus on the variables that intertwine to generate the meaning of texts on display. International tourist resorts, largely multilingual, reveal how languages in signage combine and respond to the sociolinguistic profile of their readership. However, these settings have received scant attention in the…

  6. The development of medical museums in the antebellum American South: slave bodies in networks of anatomical exchange.

    Science.gov (United States)

    Kenny, Stephen C

    2013-01-01

    Prior to the American Civil War, museums were enthusiastically promoted in the annual circulars of southern medical colleges as valuable aids to medical education. Using case history narratives, medical college circulars, and announcements, this article examines the social origins of the region's collections of anatomical and pathological specimens and explores the professional agents and organizations responsible for their maintenance and development. The article is also concerned with exploring the racial framework in which these bodies and specimens were sourced and displayed. The social relations embodied in natural history and medical museum collections, and the emerging specialism of "negro medicine," were all elements of a context that subordinated and objectified blackness, as well as permitting and legitimizing the exploitation of black bodies. Medical museums function as a key case study for examining power relations among physicians, slaves, and slave owners, as well as underscoring southern medicine's dependence on slavery for its development.

  7. Ribosome display: next-generation display technologies for production of antibodies in vitro.

    Science.gov (United States)

    He, Mingyue; Khan, Farid

    2005-06-01

    Antibodies represent an important and growing class of biologic research reagents and biopharmaceutical products. They can be used as therapeutics in a variety of diseases. With the rapid expansion of proteomic studies and biomarker discovery, there is a need for the generation of highly specific binding reagents to study the vast number of proteins encoded by the genome. Display technologies provide powerful tools for obtaining antibodies. Aside from the preservation of natural antibody repertoires, they are capable of exploiting diversity by DNA recombination to create very large libraries for selection of novel molecules. In contrast to in vivo immunization processes, display technologies allow selection of antibodies under in vitro-defined selection condition(s), resulting in enrichment of antibodies with desired properties from large populations. In addition, in vitro selection enables the isolation of antibodies against difficult antigens including self-antigens, and this can be applied to the generation of human antibodies against human targets. Display technologies can also be combined with DNA mutagenesis for antibody evolution in vitro. Some methods are amenable to automation, permitting high-throughput generation of antibodies. Ribosome display is considered as representative of the next generation of display technologies since it overcomes the limitations of cell-based display methods by using a cell-free system, offering advantages of screening larger libraries and continuously expanding new diversity during selection. Production of display-derived antibodies can be achieved by choosing one of a variety of prokaryotic and eukaryotic cell-based expression systems. In the near future, cell-free protein synthesis may be developed as an alternative for large-scale generation of antibodies.

  8. Alterations in Anatomical Covariance in the Prematurely Born.

    Science.gov (United States)

    Scheinost, Dustin; Kwon, Soo Hyun; Lacadie, Cheryl; Vohr, Betty R; Schneider, Karen C; Papademetris, Xenophon; Constable, R Todd; Ment, Laura R

    2017-01-01

    Preterm (PT) birth results in long-term alterations in functional and structural connectivity, but the related changes in anatomical covariance are just beginning to be explored. To test the hypothesis that PT birth alters patterns of anatomical covariance, we investigated brain volumes of 25 PTs and 22 terms at young adulthood using magnetic resonance imaging. Using regional volumetrics, seed-based analyses, and whole brain graphs, we show that PT birth is associated with reduced volume in bilateral temporal and inferior frontal lobes, left caudate, left fusiform, and posterior cingulate for prematurely born subjects at young adulthood. Seed-based analyses demonstrate altered patterns of anatomical covariance for PTs compared with terms. PTs exhibit reduced covariance with R Brodmann area (BA) 47, Broca's area, and L BA 21, Wernicke's area, and white matter volume in the left prefrontal lobe, but increased covariance with R BA 47 and left cerebellum. Graph theory analyses demonstrate that measures of network complexity are significantly less robust in PTs compared with term controls. Volumes in regions showing group differences are significantly correlated with phonological awareness, the fundamental basis for reading acquisition, for the PTs. These data suggest both long-lasting and clinically significant alterations in the covariance in the PTs at young adulthood. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Systematic significance of anatomical characterization in some euphorbiaceous species

    International Nuclear Information System (INIS)

    Zahra, N.B.; Shinwari, Z.K.

    2014-01-01

    The study was aimed to explore the systematic potential of anatomical characters for identification and delimitation among Euphorbia species. Eight species of leafy spurges of genus Euphorbia L. (Euphorbiaceae) were evaluated for variations in micro morphological characters of foliar epidermal anatomy. While anatomical observations are of importance in the assessments and appraisals, use of these characters as an effective tool in interpreting phyletic evaluations and systematic delineations has its limitations too. The epidermal cell wall in majority of species was wavy to undulate on both adaxial and abaxial surfaces. The observations made in this study indicate that there is not a single type of stomata which appears as characteristic of the genus Euphorbia. Also their distribution whether epistomatic or hypostomatic is not a genus-characteristic. The trichomes found were simple, unicellular or multicellular, uniseriate. Present investigation revealed the utility of both qualitative and quantitative characters in systematic studies; also the potential influence in the delimitation of species cannot be ignored. Our results show that the micro-morphology of anatomical characters play an important role in definition of taxa at species and sectional levels. (author)

  10. The Effects of FreeSurfer Version, Workstation Type, and Macintosh Operating System Version on Anatomical Volume and Cortical Thickness Measurements

    OpenAIRE

    Gronenschild, Ed H. B. M.; Habets, Petra; Jacobs, Heidi I. L.; Mengelers, Ron; Rozendaal, Nico; van Os, Jim; Marcelis, Machteld

    2012-01-01

    FreeSurfer is a popular software package to measure cortical thickness and volume of neuroanatomical structures. However, little if any is known about measurement reliability across various data processing conditions. Using a set of 30 anatomical T1-weighted 3T MRI scans, we investigated the effects of data processing variables such as FreeSurfer version (v4.3.1, v4.5.0, and v5.0.0), workstation (Macintosh and Hewlett-Packard), and Macintosh operating system version (OSX 10.5 and OSX 10.6). S...

  11. Living AnatoME: Teaching and Learning Musculoskeletal Anatomy through Yoga and Pilates

    Science.gov (United States)

    McCulloch, Carrie; Marango, Stephanie Pieczenik; Friedman, Erica S.; Laitman, Jeffrey T.

    2010-01-01

    Living AnatoME, a program designed in 2004 by two medical students in conjunction with the Director of Anatomy, teaches musculoskeletal anatomy through yoga and Pilates. Previously offered as an adjunct to the Gross Anatomy course in 2007, Living AnatoME became an official part of the curriculum. Previous research conducted on the program…

  12. Large-screen display industry: market and technology trends for direct view and projection displays

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1996-03-01

    Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.

  13. Influences on anatomical knowledge: The complete arguments

    NARCIS (Netherlands)

    Bergman, E.M.; Verheijen, I.W.; Scherpbier, A.J.J.A.; Vleuten, C.P.M. van der; Bruin, A.B. De

    2014-01-01

    Eight factors are claimed to have a negative influence on anatomical knowledge of medical students: (1) teaching by nonmedically qualified teachers, (2) the absence of a core anatomy curriculum, (3) decreased use of dissection as a teaching tool, (4) lack of teaching anatomy in context, (5)

  14. Comparison of ultrasound-guided versus anatomical landmark ...

    African Journals Online (AJOL)

    Background Femoral vein cannulation may be required during major surgery in infants and children and may prove to be life saving under certain conditions. This study compared ultrasound (US)-guided cannulation of the femoral vein in infants with the traditional anatomical landmark-guided technique. Methods Eighty ...

  15. Anatomic partial nephrectomy: technique evolution.

    Science.gov (United States)

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  16. Brain anatomical network and intelligence.

    Directory of Open Access Journals (Sweden)

    Yonghui Li

    2009-05-01

    Full Text Available Intuitively, higher intelligence might be assumed to correspond to more efficient information transfer in the brain, but no direct evidence has been reported from the perspective of brain networks. In this study, we performed extensive analyses to test the hypothesis that individual differences in intelligence are associated with brain structural organization, and in particular that higher scores on intelligence tests are related to greater global efficiency of the brain anatomical network. We constructed binary and weighted brain anatomical networks in each of 79 healthy young adults utilizing diffusion tensor tractography and calculated topological properties of the networks using a graph theoretical method. Based on their IQ test scores, all subjects were divided into general and high intelligence groups and significantly higher global efficiencies were found in the networks of the latter group. Moreover, we showed significant correlations between IQ scores and network properties across all subjects while controlling for age and gender. Specifically, higher intelligence scores corresponded to a shorter characteristic path length and a higher global efficiency of the networks, indicating a more efficient parallel information transfer in the brain. The results were consistently observed not only in the binary but also in the weighted networks, which together provide convergent evidence for our hypothesis. Our findings suggest that the efficiency of brain structural organization may be an important biological basis for intelligence.

  17. Relapse and stability of surgically assisted rapid maxillary expansion, an anatomical biomechanical study

    NARCIS (Netherlands)

    Koudstaal, M.J.; Smeets, J.B.J.; Kleinrensink, G.J.; Schulten, A.J.M.; van der Wal, K.G.H.

    2009-01-01

    Purpose: This anatomic biomechanical study was undertaken to gain insight into the underlining mechanism of tipping of the maxillary segments during transverse expansion using tooth-borne and bone-borne distraction devices. Materials and Methods: An anatomic biomechanical study was performed on 10

  18. Surface anatomy and anatomical planes in the adult turkish population.

    Science.gov (United States)

    Uzun, C; Atman, E D; Ustuner, E; Mirjalili, S A; Oztuna, D; Esmer, T S

    2016-03-01

    Surface anatomy and anatomical planes are widely used in education and clinical practice. The planes are largely derived from cadaveric studies and their projections on the skin show discrepancies between and within anatomical reference textbooks. In this study, we reassessed the accuracy of common thoracic and abdominopelvic anatomical planes using computed tomography (CT) imaging in the live adult Turkish population. After patients with distorting pathologies had been excluded, CT images of 150 supine patients at the end tidal inspiration were analyzed. Sternal angle, transpyloric, subcostal, supracristal and pubic crest planes and their relationships to anatomical structures were established by dual consensus. The tracheal bifurcation, azygos vein/superior vena cava (SVC) junction and pulmonary bifurcation were usually below the sternal angle while the concavity of the aortic arch was generally within the plane. The tip of the tenth rib, the superior mesenteric artery and the portal vein were usually within the transpyloric plane while the renal hila and the fundus of the gallbladder were below it. The inferior mesenteric artery was below the subcostal plane and the aortic bifurcation was below the supracristal plane in most adults. Projectional surface anatomy is fundamental to medical education and clinical practice. Modern cross-sectional imaging techniques allow large groups of live patients to be examined. Classic textbook information regarding anatomy needs to be reviewed and updated using the data gathered from these recent studies, taking ethnic differences into consideration. © 2015 Wiley Periodicals, Inc.

  19. Mortimer Frank, Johann Ludwig Choulant, and the history of anatomical illustration.

    Science.gov (United States)

    Feibel, Robert M

    2018-01-01

    Mortimer Frank (1874-1919) was an ophthalmologist in Chicago, Illinois. He published a number of papers on the history of medicine, and was secretary of the Chicago Society of the History of Medicine and editor of their Bulletin. His major contribution to the history of medicine relates to the history of anatomical illustration. The classic book on that subject had been published in 1852 in German by the physician and historian, Johann Ludwig Choulant (1791-1861). However, by Frank's time this text was both out dated and out of print. Frank took on the tremendous project of translating Choulant's German text into English as History and Bibliography of Anatomic Illustration in Its Relation to Anatomic Science and The Graphic Arts. He improved Choulant's text with the results of his and other scholars' research, greatly enlarging the text. Frank supplemented the original book with a biography of Choulant, essays on anatomists not considered in the original text, and an essay on the history of anatomical illustration prior to those authors discussed by Choulant. This book, now referred to as Choulant/Frank, has been reprinted several times, and is still useful as a reference in this field, though some of its research is now dated.

  20. Anatomic variation and orgasm: Could variations in anatomy explain differences in orgasmic success?

    Science.gov (United States)

    Emhardt, E; Siegel, J; Hoffman, L

    2016-07-01

    Though the public consciousness is typically focused on factors such as psychology, penis size, and the presence of the "G-spot," there are other anatomical and neuro-anatomic differences that could play an equal, or more important, role in the frequency and intensity of orgasms. Discovering these variations could direct further medical or procedural management to improve sexual satisfaction. The aim of this study is to review the available literature of anatomical sexual variation and to explain why this variation may predispose some patients toward a particular sexual experience. In this review, we explored the available literature on sexual anatomy and neuro-anatomy. We used PubMed and OVID Medline for search terms, including orgasm, penile size variation, clitoral variation, Grafenberg spot, and benefits of orgasm. First we review the basic anatomy and innervation of the reproductive organs. Then we describe several anatomical variations that likely play a superior role to popular known variation (penis size, presence of g-spot, etc). For males, the delicate play between the parasympathetic and sympathetic nervous systems is vital to achieve orgasm. For females, the autonomic component is more complex. The clitoris is the primary anatomical feature for female orgasm, including its migration toward the anterior vaginal wall. In conclusions, orgasms are complex phenomena involving psychological, physiological, and anatomic variation. While these variations predispose people to certain sexual function, future research should explore how to surgically or medically alter these. Clin. Anat. 29:665-672, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. A hierarchical scheme for geodesic anatomical labeling of airway trees

    DEFF Research Database (Denmark)

    Feragen, Aasa; Petersen, Jens; Owen, Megan

    2012-01-01

    We present a fast and robust supervised algorithm for label- ing anatomical airway trees, based on geodesic distances in a geometric tree-space. Possible branch label configurations for a given unlabeled air- way tree are evaluated based on the distances to a training set of labeled airway trees....... In tree-space, the airway tree topology and geometry change continuously, giving a natural way to automatically handle anatomical differences and noise. The algorithm is made efficient using a hierarchical approach, in which labels are assigned from the top down. We only use features of the airway...

  2. Increased cortical-limbic anatomical network connectivity in major depression revealed by diffusion tensor imaging.

    Directory of Open Access Journals (Sweden)

    Peng Fang

    Full Text Available Magnetic resonance imaging studies have reported significant functional and structural differences between depressed patients and controls. Little attention has been given, however, to the abnormalities in anatomical connectivity in depressed patients. In the present study, we aim to investigate the alterations in connectivity of whole-brain anatomical networks in those suffering from major depression by using machine learning approaches. Brain anatomical networks were extracted from diffusion magnetic resonance images obtained from both 22 first-episode, treatment-naive adults with major depressive disorder and 26 matched healthy controls. Using machine learning approaches, we differentiated depressed patients from healthy controls based on their whole-brain anatomical connectivity patterns and identified the most discriminating features that represent between-group differences. Classification results showed that 91.7% (patients=86.4%, controls=96.2%; permutation test, p<0.0001 of subjects were correctly classified via leave-one-out cross-validation. Moreover, the strengths of all the most discriminating connections were increased in depressed patients relative to the controls, and these connections were primarily located within the cortical-limbic network, especially the frontal-limbic network. These results not only provide initial steps toward the development of neurobiological diagnostic markers for major depressive disorder, but also suggest that abnormal cortical-limbic anatomical networks may contribute to the anatomical basis of emotional dysregulation and cognitive impairments associated with this disease.

  3. Visualisation of bony and vascular structures via digital subtraction images upon the amount of anatomic background

    International Nuclear Information System (INIS)

    Hinz, A.; Scholz, A.; Zwicker, C.

    1992-01-01

    We examined the loss of contrast leaving a part of the anatomic background in digital subtraction angiography by visual analysis and densitometry. We observed a greater loss of the quality at the representation of the bone below than above an amount of anatomic background of 60%. The loss of quality at the representation of the vessels decreases more above than below an anatomical background of 45%. We think that, depending on the clinical problem, an anatomical background between 15 and 30% should be left. (orig.) [de

  4. Scalable Resolution Display Walls

    KAUST Repository

    Leigh, Jason; Johnson, Andrew; Renambot, Luc; Peterka, Tom; Jeong, Byungil; Sandin, Daniel J.; Talandis, Jonas; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung; Sun, Yiwen

    2013-01-01

    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  5. Handbook of anatomical models for radiation dosimetry

    CERN Document Server

    Eckerman, Keith F

    2010-01-01

    Covering the history of human model development, this title presents the major anatomical and physical models that have been developed for human body radiation protection, diagnostic imaging, and nuclear medicine therapy. It explores how these models have evolved and the role that modern technologies have played in this development.

  6. Anatomic Aspects of Formation and Growth of the Cape Gooseberry Fruit Physalis peruviana (Solanaceae

    Directory of Open Access Journals (Sweden)

    Manuel Fernando Mazorra

    2006-01-01

    confirmed that anatomically the Cape gooseberry fruits, ecotipo Colombia, and ruderal type are similar, which demonstrates the absence of appreciable anatomical changes that explain the greater size of the fruits of ecotipo Colombia.

  7. The ligament of Parks as a key anatomical structure for safer hemorrhoidectomy: Anatomic study and a simple surgical note

    Directory of Open Access Journals (Sweden)

    Menelaos Zoulamoglou

    2017-12-01

    Full Text Available Hemorrhoids are a common anal disorder which affects both men and women of all ages. One out of ten patients with hemorrhoidal disease, requires surgical treatment. Unfortunately though, hemorrhoidectomy is closely related to complications that can be present early or late postoperatively. In the present manuscript, the safe surgical technique which emphasizes to the identification of the key anatomical structure of the ligament of Parks (Trietz's muscle is adequately described. A total of 200 patients with grades III and IV hemorrhoids, underwent Milligan-Morgan or Ferguson's hemorrhoidectomy. The mucosal ligament of Parks was identified to all patients and was used as a key anatomical structure through the excision of the hemorrhoids. Its identification guides surgeons during the operation and reduces the major problem of postoperative complications. Finally, since the mucosal ligament of Parks represents a constantly identifiable landmark, it allows simple and reliable identification of the internal sphincter muscle and minimizes the probability of postoperative complications.

  8. X-Windows Widget for Image Display

    Science.gov (United States)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  9. Study on the visibility of an electroluminescent display for automobiles; Jidoshayo EL display no shininsei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, N; Harada, M; Idogaki, T [Denso Corp., Aichi (Japan)

    1997-10-01

    This report explores the visibility of an Electroluminescent (EL) display for automotive use. Displays for automobiles are exposed to the direct rays of the sun and forced to operate in wide temperature range. Therefore, luminous flux density by the lighting on EL display panel and operating environment temperature must be considered for the visibility evaluation. Sensory evaluation on the visibility and physical measurements such as contrast, chromaticity difference in accordance with the viewing angle change indicate that the visibility of the EL display for automobiles is advantageous over other displays. 6 refs., 11 figs., 1 tab.

  10. Anatomical Modularity of Verbal Working Memory? Functional Anatomical Evidence from a Famous Patient with Short-Term Memory Deficits.

    Science.gov (United States)

    Paulesu, Eraldo; Shallice, Tim; Danelli, Laura; Sberna, Maurizio; Frackowiak, Richard S J; Frith, Chris D

    2017-01-01

    Cognitive skills are the emergent property of distributed neural networks. The distributed nature of these networks does not necessarily imply a lack of specialization of the individual brain structures involved. However, it remains questionable whether discrete aspects of high-level behavior might be the result of localized brain activity of individual nodes within such networks. The phonological loop of working memory, with its simplicity, seems ideally suited for testing this possibility. Central to the development of the phonological loop model has been the description of patients with focal lesions and specific deficits. As much as the detailed description of their behavior has served to refine the phonological loop model, a classical anatomoclinical correlation approach with such cases falls short in telling whether the observed behavior is based on the functions of a neural system resembling that seen in normal subjects challenged with phonological loop tasks or whether different systems have taken over. This is a crucial issue for the cross correlation of normal cognition, normal physiology, and cognitive neuropsychology. Here we describe the functional anatomical patterns of JB, a historical patient originally described by Warrington et al. (1971), a patient with a left temporo-parietal lesion and selective short phonological store deficit. JB was studied with the H 2 15 O PET activation technique during a rhyming task, which primarily depends on the rehearsal system of the phonological loop. No residual function was observed in the left temporo-parietal junction, a region previously associated with the phonological buffer of working memory. However, Broca's area, the major counterpart of the rehearsal system, was the major site of activation during the rhyming task. Specific and autonomous activation of Broca's area in the absence of afferent inputs from the other major anatomical component of the phonological loop shows that a certain degree of

  11. Visual agnosia and posterior cerebral artery infarcts: an anatomical-clinical study.

    Science.gov (United States)

    Martinaud, Olivier; Pouliquen, Dorothée; Gérardin, Emmanuel; Loubeyre, Maud; Hirsbein, David; Hannequin, Didier; Cohen, Laurent

    2012-01-01

    To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA) strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct) with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA), faces (FFA and OFA), houses (PPA) and common objects (LOC). Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words). Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations.

  12. Visual agnosia and posterior cerebral artery infarcts: an anatomical-clinical study.

    Directory of Open Access Journals (Sweden)

    Olivier Martinaud

    Full Text Available BACKGROUND: To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. METHODS AND FINDINGS: We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA, faces (FFA and OFA, houses (PPA and common objects (LOC. Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words. Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. CONCLUSIONS: Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations.

  13. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  14. A multi-subject evaluation of uncertainty in anatomical landmark location on shoulder kinematic description.

    Science.gov (United States)

    Langenderfer, Joseph E; Rullkoetter, Paul J; Mell, Amy G; Laz, Peter J

    2009-04-01

    An accurate assessment of shoulder kinematics is useful for understanding healthy normal and pathological mechanics. Small variability in identifying and locating anatomical landmarks (ALs) has potential to affect reported shoulder kinematics. The objectives of this study were to quantify the effect of landmark location variability on scapular and humeral kinematic descriptions for multiple subjects using probabilistic analysis methods, and to evaluate the consistency in results across multiple subjects. Data from 11 healthy subjects performing humeral elevation in the scapular plane were used to calculate Euler angles describing humeral and scapular kinematics. Probabilistic analyses were performed for each subject to simulate uncertainty in the locations of 13 upper-extremity ALs. For standard deviations of 4 mm in landmark location, the analysis predicted Euler angle envelopes between the 1 and 99 percentile bounds of up to 16.6 degrees . While absolute kinematics varied with the subject, the average 1-99% kinematic ranges for the motion were consistent across subjects and sensitivity factors showed no statistically significant differences between subjects. The description of humeral kinematics was most sensitive to the location of landmarks on the thorax, while landmarks on the scapula had the greatest effect on the description of scapular elevation. The findings of this study can provide a better understanding of kinematic variability, which can aid in making accurate clinical diagnoses and refining kinematic measurement techniques.

  15. OLED displays and lighting

    CERN Document Server

    Koden, Mitsuhiro

    2017-01-01

    Organic light-emitting diodes (OLEDs) have emerged as the leading technology for the new display and lighting market. OLEDs are solid-state devices composed of thin films of organic molecules that create light with the application of electricity. OLEDs can provide brighter, crisper displays on electronic devices and use less power than conventional light-emitting diodes (LEDs) or liquid crystal displays (LCDs) used today. This book covers both the fundamentals and practical applications of flat and flexible OLEDs.

  16. Laser display system for multi-depth screen projection scenarios.

    Science.gov (United States)

    La Torre, J Pablo; Mayes, Nathan; Riza, Nabeel A

    2017-11-10

    Proposed is a laser projection display system that uses an electronically controlled variable focus lens (ECVFL) to achieve sharp and in-focus image projection over multi-distance three-dimensional (3D) conformal screens. The system also functions as an embedded distance sensor that enables 3D mapping of the multi-level screen platform before the desired laser scanned beam focused/defocused projected spot sizes are matched to the different localized screen distances on the 3D screen. Compared to conventional laser scanning and spatial light modulator (SLM) based projection systems, the proposed design offers in-focus non-distorted projection over a multi-distance screen zone with varying depths. An experimental projection system for a screen depth variation of 65 cm is demonstrated using a 633 nm laser beam, 3 KHz scan speed galvo-scanning mirrors, and a liquid-based ECVFL. As a basic demonstration, an in-house developed MATLAB based graphic user interface is deployed to work along with the laser projection display, enabling user inputs like text strings or predefined image projection. The user can specify projection screen distance, scanned laser linewidth, projected text font size, projected image dimensions, and laser scanning rate. Projected images are shown highlighting the 3D control capabilities of the display, including the production of a non-distorted image onto two-depths versus a distorted image via dominant prior-art projection methods.

  17. Dichroic Liquid Crystal Displays

    Science.gov (United States)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment

  18. Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

    International Nuclear Information System (INIS)

    Chetvertkov, Mikhail A.; Siddiqui, Farzan; Chetty, Indrin; Kumarasiri, Akila; Liu, Chang; Gordon, J. James; Kim, Jinkoo

    2016-01-01

    Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more

  19. Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

    Energy Technology Data Exchange (ETDEWEB)

    Chetvertkov, Mikhail A., E-mail: chetvertkov@wayne.edu [Department of Radiation Oncology, Wayne State University School of Medicine, Detroit, Michigan 48201 and Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202 (United States); Siddiqui, Farzan; Chetty, Indrin; Kumarasiri, Akila; Liu, Chang; Gordon, J. James [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202 (United States); Kim, Jinkoo [Department of Radiation Oncology, Stony Brook University Hospital, Stony Brook, New York 11794 (United States)

    2016-10-15

    Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more

  20. Color dependence with horizontal-viewing angle and colorimetric characterization of two displays using different backlighting

    Science.gov (United States)

    Castro, José J.; Pozo, Antonio M.; Rubiño, Manuel

    2013-11-01

    In this work we studied the color dependence with a horizontal-viewing angle and colorimetric characterization of two liquid-crystal displays (LCD) using two different backlighting: Cold Cathode Fluorescent Lamps (CCFLs) and light-emitting diodes (LEDs). The LCDs studied had identical resolution, size, and technology (TFT - thin film transistor). The colorimetric measurements were made with the spectroradiometer SpectraScan PR-650 following the procedure recommended in the European guideline EN 61747-6. For each display, we measured at the centre of the screen the chromaticity coordinates at horizontal viewing angles of 0, 20, 40, 60 and 80 degrees for the achromatic (A), red (R), green (G) and blue (B) channels. Results showed a greater color-gamut area for the display with LED backlight, compared with the CCFL backlight, showing a greater range of colors perceptible by human vision. This color-gamut area diminished with viewing angle for both displays. Higher differences between trends for viewing angles were observed in the LED-backlight, especially for the R- and G-channels, demonstrating a higher variability of the chromaticity coordinates with viewing angle. The best additivity was reached by the LED-backlight display (a lower error percentage). LED-backlight display provided better color performance of visualization.

  1. Exploring the human body space: A geographical information system based anatomical atlas

    Directory of Open Access Journals (Sweden)

    Antonio Barbeito

    2016-06-01

    Full Text Available Anatomical atlases allow mapping the anatomical structures of the human body. Early versions of these systems consisted of analogical representations with informative text and labeled images of the human body. With computer systems, digital versions emerged and the third and fourth dimensions were introduced. Consequently, these systems increased their efficiency, allowing more realistic visualizations with improved interactivity and functionality. The 4D atlases allow modeling changes over time on the structures represented. The anatomical atlases based on geographic information system (GIS environments allow the creation of platforms with a high degree of interactivity and new tools to explore and analyze the human body. In this study we expand the functions of a human body representation system by creating new vector data, topology, functions, and an improved user interface. The new prototype emulates a 3D GIS with a topological model of the human body, replicates the information provided by anatomical atlases, and provides a higher level of functionality and interactivity. At this stage, the developed system is intended to be used as an educational tool and integrates into the same interface the typical representations of surface and sectional atlases.

  2. Early Results of Anatomic Double Bundle Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Demet Pepele

    2014-03-01

    Full Text Available Aim: The goal in anterior cruciate ligament reconstruction (ACLR is to restore the normal anatomic structure and function of the knee. In the significant proportion of patients after the traditional single-bundle ACLR, complaints of instability still continue. Anatomic double bundle ACLR may provide normal kinematics in knees, much closer to the natural anatomy. The aim of this study is to clinically assess the early outcomes of our anatomical double bundle ACLR. Material and Method: In our clinic between June 2009 and March 2010, performed the anatomic double bundle ACLR with autogenous hamstring grafts 20 patients were evaluated prospectively with Cincinnati, IKDC and Lysholm scores and in clinically for muscle strength and with Cybex II dynamometer. Results: The mean follow-up is 17.8 months (13-21 months. Patients%u2019 scores of Cincinnati, IKDC and Lysholm were respectively, preoperative 18.1, 39.3 and 39.8, while the post-op increased to 27.2, 76.3 and 86.3. In their last check, 17 percent of the patients according to IKDC scores (85% A (excellent and B (good group and 3 patients took place as C (adequate group. The power measurements of quadriceps and hamstring muscle groups of patients who underwent surgery showed no significant difference compared with the intact knees. Discussion: Double-bundle ACL reconstruction is a satisfactory method. There is a need comparative, long-term studies in large numbers in order to determine improving clinical outcome, preventing degeneration and restoring the knee biomechanics better.

  3. Renal mass anatomic characteristics and perioperative outcomes of laparoscopic partial nephrectomy: a critical analysis.

    Science.gov (United States)

    Tsivian, Matvey; Ulusoy, Said; Abern, Michael; Wandel, Ayelet; Sidi, A Ami; Tsivian, Alexander

    2012-10-01

    Anatomic parameters determining renal mass complexity have been used in a number of proposed scoring systems despite lack of a critical analysis of their independent contributions. We sought to assess the independent contribution of anatomic parameters on perioperative outcomes of laparoscopic partial nephrectomy (LPN). Preoperative imaging studies were reviewed for 147 consecutive patients undergoing LPN for a single renal mass. Renal mass anatomy was recorded: Size, growth pattern (endo-/meso-/exophytic), centrality (central/hilar/peripheral), anterior/posterior, lateral/medial, polar location. Multivariable models were used to determine associations of anatomic parameters with warm ischemia time (WIT), operative time (OT), estimated blood loss (EBL), intra- and postoperative complications, as well as renal function. All models were adjusted for the learning curve and relevant confounders. Median (range) tumor size was 3.3 cm (1.5-11 cm); 52% were central and 14% hilar. While 44% were exophytic, 23% and 33% were mesophytic and endophytic, respectively. Anatomic parameters did not uniformly predict perioperative outcomes. WIT was associated with tumor size (P=0.068), centrality (central, P=0.016; hilar, P=0.073), and endophytic growth pattern (P=0.017). OT was only associated with tumor size (Panatomic parameter predicted EBL. Tumor centrality increased the odds of overall and intraoperative complications, without reaching statistical significance. Postoperative renal function was not associated with any of the anatomic parameters considered after adjustment for baseline function and WIT. Learning curve, considered as a confounder, was independently associated with reduced WIT and OT as well as reduced odds of intraoperative complications. This study provides a detailed analysis of the independent impact of renal mass anatomic parameters on perioperative outcomes. Our findings suggest diverse independent contributions of the anatomic parameters to the

  4. MR urography: Anatomical and quantitative information on ...

    African Journals Online (AJOL)

    Background and Aim: Magnetic resonance urography (MRU) is considered to be the next step in uroradiology. This technique combines superb anatomical images and functional information in a single test. In this article, we aim to present the topic of MRU in children and how it has been implemented in Northern Greece so ...

  5. Anatomical and physical changes in leaves during the production of tamales.

    Science.gov (United States)

    Angeles, Guillermo; Lascurain, Maite; Davalos-Sotelo, Raymundo; Zarate-Morales, Reyna Paula; Ortega-Escalona, Fernando

    2013-08-01

    Tamale preparation has a long tradition in Mexico. To understand which material properties have been considered important for this purpose throughout the years, a study was conducted of the anatomical, chemical, and mechanical properties of the leaves of four plant species used in tamale preparation in Veracruz, Mexico: Calathea misantlensis, Canna indica, Musa paradisiaca, and Oreopanax capitatus. Four cooking treatments were considered: fresh (F), roasted (soasado, R), steamed (S), and roasted plus steamed (R/S). Chemical, anatomical, and mechanical analyses were conducted before and after each treatment. Leaf samples were tested for tensile strength at both parallel and perpendicular orientation relative to the fibers. Musa paradisiaca had the highest proportion of cellulose, while the remaining species shared similar lower proportions. Leaves were stronger and stiffer in the longitudinal direction of the fibers. Musa paradisiaca leaves had higher values of mechanical strength than the other species. The cooking process that most affected the mechanical properties was steaming. The chemical constituents of the leaves are closely correlated with their physical properties. The treatment that caused the greatest decrease in leaf physical integrity was steaming, while the combination of roasting and steaming showed similar results to those of steaming alone. No evident anatomical changes are produced by any of the treatments. This is one of the few studies comparing physical, chemical, and anatomical characteristics of leaves used for human consumption, before and after cooking.

  6. The nonvisual illusion of self-touch: Misaligned hands and anatomical implausibility.

    Science.gov (United States)

    White, Rebekah C; Weinberg, Jennifer L; Aimola Davies, Anne M

    2015-01-01

    The self-touch illusion is elicited when the participant (with eyes closed) administers brushstrokes to a prosthetic hand while the examiner administers synchronous brushstrokes to the participant's other (receptive) hand. In three experiments we investigated the effects of misalignment on the self-touch illusion. In experiment 1 we manipulated alignment (0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees) of the prosthetic hand relative to the participant's receptive hand. The illusion was equally strong at 0 degrees and 45 degrees: the two conditions in which the prosthetic hand was in an anatomically plausible orientation. To investigate whether the illusion was diminished at 90 degrees (and beyond) by anatomical implausibility rather than by misalignment, in experiment 2 hand positioning was changed. The illusion was equally strong at 0 degrees, 45 degrees, and 90 degrees, but diminished at 135 degrees despite the prosthetic hand now being in an anatomically plausible orientation. Thus the illusion is diminished with misalignment of 135 degrees, irrespective of anatomical plausibility. Having demonstrated that the illusion was equally strong with the hands aligned (0 degrees) or misaligned by 45 degrees, in experiment 3 we demonstrated that participants did not detect a 45 degrees misalignment. Large degrees of misalignment prevent a compelling experience of the self-touch illusion, and the self-touch illusion prevents detection of small degrees of misalignment.

  7. Functional cervicothoracic boundary modified by anatomical shifts in the neck of giraffes.

    Science.gov (United States)

    Gunji, Megu; Endo, Hideki

    2016-02-01

    Here we examined the kinematic function of the morpho- logically unique first thoracic vertebra in giraffes. The first thoracic vertebra of the giraffe displayed similar shape to the seventh cervical vertebra in general ruminants. The flexion experiment using giraffe carcasses demonstrated that the first thoracic vertebra exhibited a higher dorsoventral mobility than other thoracic vertebrae. Despite the presence of costovertebral joints, restriction in the intervertebral movement imposed by ribs is minimized around the first thoracic vertebra by subtle changes of the articular system between the vertebra and ribs. The attachment area of musculus longus colli, mainly responsible for ventral flexion of the neck, is partly shifted posteriorly in the giraffe so that the force generated by muscles is exerted on the cervical vertebrae and on the first thoracic vertebra. These anatomical modifications allow the first thoracic vertebra to adopt the kinematic function of a cervical vertebra in giraffes. The novel movable articulation in the thorax functions as a fulcrum of neck movement and results in a large displacement of reachable space in the cranial end of the neck. The unique first thoracic vertebra in giraffes provides higher flexibility to the neck and may provide advantages for high browsing and/or male competition behaviours specific to giraffes.

  8. Crosstalk evaluation in stereoscopic displays

    NARCIS (Netherlands)

    Wang, L.; Teunissen, C.; Tu, Yan; Chen, Li; Zhang, P.; Zhang, T.; Heynderickx, I.E.J.

    2011-01-01

    Substantial progress in liquid-crystal display and polarization film technology has enabled several types of stereoscopic displays. Despite all progress, some image distortions still exist in these 3-D displays, of which interocular crosstalk - light leakage of the image for one eye to the other eye

  9. Anatomical variability in the trajectory of the inside-out transobturator vaginal tape technique (TVT-O)

    NARCIS (Netherlands)

    Hinoul, Piet; Vanormelingen, Linda; Roovers, Jan-Paul; de Jonge, Eric; Smajda, Stéfan

    2007-01-01

    An experimental surgical study on human cadavers was undertaken to assess variability in the trajectory followed by the needle during application of the inside-out transobturator tape suspension (TVT-O) technique. The TVT-O surgical procedures were performed on six fresh female cadavers according to

  10. Anatomic abnormalities of the anterior cingulate cortex before psychosis onset: an MRI study of ultra-high-risk individuals.

    Science.gov (United States)

    Fornito, Alex; Yung, Alison R; Wood, Stephen J; Phillips, Lisa J; Nelson, Barnaby; Cotton, Sue; Velakoulis, Dennis; McGorry, Patrick D; Pantelis, Christos; Yücel, Murat

    2008-11-01

    Abnormalities of the anterior cingulate cortex (ACC) are frequently implicated in the pathophysiology of psychotic disorders, but whether such changes are apparent before psychosis onset remains unclear. In this study, we characterized prepsychotic ACC abnormalities in a sample of individuals at ultra-high-risk (UHR) for psychosis. Participants underwent baseline magnetic resonance imaging and were followed-up over 12-24 months to ascertain diagnostic outcomes. Baseline ACC morphometry was then compared between UHR individuals who developed psychosis (UHR-P; n = 35), those who did not (UHR-NP; n = 35), and healthy control subjects (n = 33). Relative to control subjects, UHR-P individuals displayed bilateral thinning of a rostral paralimbic ACC region that was negatively correlated with negative symptoms, whereas UHR-NP individuals displayed a relative thickening of dorsal and rostral limbic areas that was correlated with anxiety ratings. Baseline ACC differences between the two UHR groups predicted time to psychosis onset, independently of symptomatology. Subdiagnostic comparisons revealed that changes in the UHR-P group were driven by individuals subsequently diagnosed with a schizophrenia spectrum psychosis. These findings indicate that anatomic abnormalities of the ACC precede psychosis onset and that baseline ACC differences distinguish between UHR individuals who do and do not subsequently develop frank psychosis. They also indicate that prepsychotic changes are relatively specific to individuals who develop a schizophrenia spectrum disorder, suggesting they may represent a diagnostically specific risk marker.

  11. Conflict resolution maneuvers during near miss encounters with cockpit traffic displays

    Science.gov (United States)

    Palmer, E.

    1983-01-01

    The benefits and liabilities associated with pilots' use of a cockpit traffic display to assess the threat posed by air traffic and to make small maneuvers to avoid situations which would result in collision avoidance advisories are experimentally studied. The crew's task was to fly a simulated wide-body aircraft along a straight course at constant altitude while intruder aircraft appeared on a variety of converging trajectories. The main experimental variables were the amount and quality of the information displayed on the intruder aircraft's estimated future position. Pilots were to maintain a horizontal separation of at least 1.5 nautical miles or a vertical separation of 500 ft, so that collision avoidance advisories would not be triggered. The results show that pilots could usually maneuver to provide the specified separation but often made course deviations greater than 1.5 nm or 500 ft.

  12. An Application of Geospatial Information Systems (GIS) Technology to Anatomic Dental Charting

    OpenAIRE

    Bartling, William C.; Schleyer, Titus K.L.

    2003-01-01

    Historically, an anatomic dental chart is a compilation of color-coded symbols and numbers used within a template, either paper or computerized, to create a graphic record of a patient’s oral health status. This poster depicts how Geospatial Information System (GIS) technology can be used to create an accurate, current anatomic dental chart that contains detailed information not present in current charting systems.

  13. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  14. Anatomic variations in vascular and collecting systems of kidneys from deceased donors.

    Science.gov (United States)

    Costa, H C; Moreira, R J; Fukunaga, P; Fernandes, R C; Boni, R C; Matos, A C

    2011-01-01

    Nephroureterectomy for transplantation has increased owing to the greater number of deceased donors. Anatomic variations may complicate the procedure or, if unrecognized, compromise the viability of kidneys for transplantation. We reviewed 254 surgical descriptions of nephroureterectomy specimens from January 2008 to December 2009. All organs collected according by standard techniques were evaluated for age, cause of death, renal function, frequency of injury during the procedure, as well as variations in the vascular and collecting systems. The mean donor age was 42 years (range, 2-74). The mean serum creatinine was 1.2 mg/dL (range, 1.0-7.0). The causes of death were cerebrovascular cause (stroke; n = 130), traumatic brain injury (n = 81) or other cause (n = 43). Among the anatomic variations: 8.6% (n = 22) were right arterial anatomical variations: 19 cases with 2 arteries and 3 cases with 3 arteries. In 25 cases (9.8%) the identified variation was the left artery: 2 arteries (n = 23), 3 arteries (n = 1) and 4 arteries (n = 1). We observed 9.8% on right side and 1.5% on left side venous anatomic variations, including 24 cases with 2 veins on the right side and 4 cases with 2 veins on the left side. Three cases of a retroaortic left renal vein and 1 case of a retro necklace vein (anterior and posterior to the aorta). Two cases of ureteral duplication were noted on the left and 1 on the right kidney. There were 3 horseshoe and 1 pelvic kidney. In 7.5% of cases, an injury to the graft included ureteral (n = 3), arterial (n = 10), or venous (n = 6). The most common anatomic variation was arterial (17.8%). Duplication of the renal vein was more frequent on the right. The high incidences of anatomic variations require more attention in the dissection of the renal hilum to avoid an injury that may compromise the graft. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Proximity of arthroscopic ankle stabilization procedures to surrounding structures: an anatomic study.

    Science.gov (United States)

    Drakos, Mark; Behrens, Steve B; Mulcahey, Mary K; Paller, David; Hoffman, Eve; DiGiovanni, Christopher W

    2013-06-01

    To examine the anatomy of the lateral ankle after arthroscopic repair of the lateral ligament complex (anterior talofibular ligament [ATFL] and calcaneofibular ligament [CFL]) with regard to structures at risk. Ten lower extremity cadaveric specimens were obtained and were screened for gross anatomic defects and pre-existing ankle laxity. The ATFL and CFL were sectioned from the fibula by an open technique. Standard anterolateral and anteromedial arthroscopy portals were made. An additional portal was created 2 cm distal to the anterolateral portal. The articular surface of the fibula was identified, and the ATFL and CFL were freed from the superficial and deeper tissues. Suture anchors were placed in the fibula at the ATFL and CFL origins and were used to repair the origin of the lateral collateral structures. The distance from the suture knot to several local anatomic structures was measured. Measurements were taken by 2 separate observers, and the results were averaged. Several anatomic structures lie in close proximity to the ATFL and CFL sutures. The ATFL sutures entrapped 9 of 55 structures, and no anatomic structures were inadvertently entrapped by the CFL sutures. The proximity of the peroneus tertius and the extensor tendons to the ATFL makes them at highest risk of entrapment, but the proximity of the intermediate branch of the superficial peroneal nerve (when present) is a risk with significant morbidity. Our results indicate that the peroneus tertius and extensor tendons have the highest risk for entrapment and show the smallest mean distances from the anchor knot to the identified structure. Careful attention to these structures, as well as the superficial peroneal nerve, is mandatory to prevent entrapment of tendons and nerves when one is attempting arthroscopic lateral ankle ligament reconstruction. Defining the anatomic location and proximity of the intervening structures adjacent to the lateral ligament complex of the ankle may help clarify the

  16. Consortium for military LCD display procurement

    Science.gov (United States)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  17. Evaluation of influences of the Viennese Anatomical School on the work of the Croatian Anatomist Jelena Krmpotic-Nemanic.

    Science.gov (United States)

    Dinjar, Kristijan; Toth, Jurica; Atalic, Bruno; Radanovic, Danijela; Maric, Svjetlana

    2012-01-01

    This paper tries to evaluate the connections between the Viennese Anatomical School and the Croatian Anatomist Jelena Krmpotic-Nemanic. 17 papers written by Professor Jelena Krmpotic-Nemanic in the last decade of her life were chosen for analyses. According to their themes they could be divided into three groups: ones which evaluate the anatomical terminology, ones which research the development of anatomical structures, and ones which describe the anatomical variations. Mentioned papers were analysed through their topics, methods of research and cited references. Analyses of the mentioned papers revealed the indirect link between the Viennese Anatomical School and the Professor Jelena Krmpotic-Nemanic, through her mentor Professor Drago Perovic, regarding the themes and the methods of her anatomical researches. It has also showed her preference for Austrian and German anatomical textbooks and atlases, primarily ones published in Vienna and Jena, rather than English and American ones. Finally, her direct connections with the Viennese Institute for the History of Medicine and the Viennese Josephinum Wax Models Museum were emphasized. Mentioned indirect and direct influences of the Viennese Anatomical School on the work of Professor Jelena Krmpotic-Nemanic were critically appraised.

  18. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    Energy Technology Data Exchange (ETDEWEB)

    Bunt, Fabian van de [VU University Medical Center, Amsterdam (Netherlands); Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul [Kaiser Permanente, Los Angeles, CA (United States)

    2015-11-15

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  19. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    International Nuclear Information System (INIS)

    Bunt, Fabian van de; Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul

    2015-01-01

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  20. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  1. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  2. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  3. Familial intracranial aneurysms: is anatomic vulnerability heritable?

    Science.gov (United States)

    Mackey, Jason; Brown, Robert D; Moomaw, Charles J; Hornung, Richard; Sauerbeck, Laura; Woo, Daniel; Foroud, Tatiana; Gandhi, Dheeraj; Kleindorfer, Dawn; Flaherty, Matthew L; Meissner, Irene; Anderson, Craig; Rouleau, Guy; Connolly, E Sander; Deka, Ranjan; Koller, Daniel L; Abruzzo, Todd; Huston, John; Broderick, Joseph P

    2013-01-01

    Previous studies have suggested that family members with intracranial aneurysms (IAs) often harbor IAs in similar anatomic locations. IA location is important because of its association with rupture. We tested the hypothesis that anatomic susceptibility to IA location exists using a family-based IA study. We identified all affected probands and first-degree relatives (FDRs) with a definite or probable phenotype in each family. We stratified each IA of the probands by major arterial territory and calculated each family's proband-FDR territory concordance and overall contribution to the concordance analysis. We then matched each family unit to an unrelated family unit selected randomly with replacement and performed 1001 simulations. The median concordance proportions, odds ratios (ORs), and P values from the 1001 logistic regression analyses were used to represent the final results of the analysis. There were 323 family units available for analysis, including 323 probands and 448 FDRs, with a total of 1176 IAs. IA territorial concordance was higher in the internal carotid artery (55.4% versus 45.6%; OR, 1.54 [1.04-2.27]; P=0.032), middle cerebral artery (45.8% versus 30.5%; OR, 1.99 [1.22-3.22]; P=0.006), and vertebrobasilar system (26.6% versus 11.3%; OR, 2.90 [1.05-8.24], P=0.04) distributions in the true family compared with the comparison family. Concordance was also higher when any location was considered (53.0% versus 40.7%; OR, 1.82 [1.34-2.46]; PIA development, we found that IA territorial concordance was higher when probands were compared with their own affected FDRs than with comparison FDRs, which suggests that anatomic vulnerability to IA formation exists. Future studies of IA genetics should consider stratifying cases by IA location.

  4. Utilization management in anatomic pathology.

    Science.gov (United States)

    Lewandrowski, Kent; Black-Schaffer, Steven

    2014-01-01

    There is relatively little published literature concerning utilization management in anatomic pathology. Nonetheless there are many utilization management opportunities that currently exist and are well recognized. Some of these impact only the cost structure within the pathology department itself whereas others reduce charges for third party payers. Utilization management may result in medical legal liabilities for breaching the standard of care. For this reason it will be important for pathology professional societies to develop national utilization guidelines to assist individual practices in implementing a medically sound approach to utilization management. © 2013.

  5. Ecophysiological and Anatomical Mechanisms behind the Nurse Effect: Which Are More Important? A Multivariate Approach for Cactus Seedlings

    Science.gov (United States)

    Delgado-Sánchez, Pablo; Yáñez-Espinosa, Laura; Jiménez-Bremont, Juan Francisco; Chapa-Vargas, Leonardo; Flores, Joel

    2013-01-01

    Background Cacti establish mostly occurs under the canopy of nurse plants which provide a less stressful micro-environment, although mechanisms underlying this process are unknown. The impact of the combination of light and watering treatments on Opuntia streptacantha (Cactaceae) seedlings was examined. Methods/Principal Findings Ecophysiological [titratable acidity, osmotic potential (‘solute potential’, Ψs), relative growth rate (RGR) and their components (NAR, SLA, and LWR)], anatomical (chloroplast density, chloroplast frequency, and cell area), and environmental [photosynthetic photon flux density (PPFD) and air temperature] sets of variables were analyzed, assessing relationships between them and measuring the intensity of the relationships. Three harvests were carried out at days 15, 30, and 45. Ψs and acidity content were the most important responses for seedling establishment. The main anatomical and environmental variables were chloroplast density and water availability, respectively. Opuntia streptacantha seedlings establish better in the shade-watering treatment, due to higher Ψs and acidity, unaffected chloroplasts, and lower PPFD. In addition, the chloroplasts of cells under high-light and non-watering treatment were clumped closer to the center of the cytosol than those under shade-drought, to avoid photoinhibition and/or to better distribute or utilize the penetrating light in the green plant tissue. Conclusions Opuntia seedlings grow better under the shade, although they can tolerate drought in open spaces by increasing and moving chloroplasts and avoiding drastic decreases in their Ψs. This tolerance could have important implications for predicting the impact of climate change on natural desert regeneration, as well as for planning reforestation-afforestation practices, and rural land uses. PMID:24312310

  6. Robotic unclamped "minimal-margin" partial nephrectomy: ongoing refinement of the anatomic zero-ischemia concept.

    Science.gov (United States)

    Satkunasivam, Raj; Tsai, Sheaumei; Syan, Sumeet; Bernhard, Jean-Christophe; de Castro Abreu, Andre Luis; Chopra, Sameer; Berger, Andre K; Lee, Dennis; Hung, Andrew J; Cai, Jie; Desai, Mihir M; Gill, Inderbir S

    2015-10-01

    Anatomic partial nephrectomy (PN) techniques aim to decrease or eliminate global renal ischemia. To report the technical feasibility of completely unclamped "minimal-margin" robotic PN. We also illustrate the stepwise evolution of anatomic PN surgery with related outcomes data. This study was a retrospective analysis of 179 contemporary patients undergoing anatomic PN at a tertiary academic institution between October 2009 and February 2013. Consecutive consented patients were grouped into three cohorts: group 1, with superselective clamping and developmental-curve experience (n = 70); group 2, with superselective clamping and mature experience (n = 60); and group 3, which had completely unclamped, minimal-margin PN (n = 49). Patients in groups 1 and 2 underwent superselective tumor-specific devascularization, whereas patients in group 3 underwent completely unclamped minimal-margin PN adjacent to the tumor edge, a technique that takes advantage of the radially oriented intrarenal architecture and anatomy. Primary outcomes assessed the technical feasibility of robotic, completely unclamped, minimal-margin PN; short-term changes in estimated glomerular filtration rate (eGFR); and development of new-onset chronic kidney disease (CKD) stage >3. Secondary outcome measures included perioperative variables, 30-d complications, and histopathologic outcomes. Demographic data were similar among groups. For similarly sized tumors (p = 0.13), percentage of kidney preserved was greater (p = 0.047) and margin width was narrower (p = 0.0004) in group 3. In addition, group 3 had less blood loss (200, 225, and 150ml; p = 0.04), lower transfusion rates (21%, 23%, and 4%; p = 0.008), and shorter hospital stay (p = 0.006), whereas operative time and 30-d complication rates were similar. At 1-mo postoperatively, median percentage reduction in eGFR was similar (7.6%, 0%, and 3.0%; p = 0.53); however, new-onset CKD stage >3 occurred less frequently in group 3 (23%, 10%, and 2%; p = 0

  7. Evolution of the Anatomical Theatre in Padova

    Science.gov (United States)

    Macchi, Veronica; Porzionato, Andrea; Stecco, Carla; Caro, Raffaele

    2014-01-01

    The anatomical theatre played a pivotal role in the evolution of medical education, allowing students to directly observe and participate in the process of dissection. Due to the increase of training programs in clinical anatomy, the Institute of Human Anatomy at the University of Padova has renovated its dissecting room. The main guidelines in…

  8. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  9. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  10. Relationship between Peeled Internal Limiting Membrane Area and Anatomic Outcomes following Macular Hole Surgery: A Quantitative Analysis

    Directory of Open Access Journals (Sweden)

    Yasin Sakir Goker

    2016-01-01

    Full Text Available Purpose. To quantitatively evaluate the effects of peeled internal limiting membrane (ILM area and anatomic outcomes following macular hole surgery using spectral domain optical coherence tomography (SD-OCT. Methods. Forty-one eyes in 37 consecutive patients with idiopathic, Gass stage 3-4 macular hole (MH were enrolled in this retrospective comparative study. All patients were divided into 2 groups according to anatomic success or failure. Basal MH diameter, peeled ILM area, and MH height were calculated using SD-OCT. Other prognostic parameters, including age, stage, preoperative BCVA, and symptom duration were also assessed. Results. Thirty-two cases were classified as anatomic success, and 9 cases were classified as anatomic failure. Peeled ILM area was significantly wider and MH basal diameter was significantly less in the anatomic success group (p=0.024 and 0.032, resp.. Other parameters did not demonstrate statistical significance. Conclusion. The findings of the present study show that the peeled ILM area can affect the anatomic outcomes of MH surgery.

  11. Australian Children's Understanding of Display Rules

    Science.gov (United States)

    Choy, Grace

    2009-01-01

    Cultural display rules govern the manifestation of emotional expressions. In compliance with display rules, the facial expressions displayed (i.e. apparent emotion) may be incongruent with the emotion experienced (i.e. real emotion). This study investigates Australian Caucasian children's understanding of display rules. A sample of 80 four year…

  12. The case for transparent depth display

    NARCIS (Netherlands)

    Kooi, F.L.

    2003-01-01

    Purpose: The continuing developments in display technology have resulted in the ability to present increasing amounts of data on computer displays. One of the coming break-throughs is generally believed to be the introduction of '3-D displays': displays with a true sense of depth. Though these types

  13. New ultraportable display technology and applications

    Science.gov (United States)

    Alvelda, Phillip; Lewis, Nancy D.

    1998-08-01

    MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.

  14. Anatomía quirúrgica del músculo glúteo mayor: espacio Intramuscular de FROD

    Directory of Open Access Journals (Sweden)

    Freddy Rodríguez-García

    Full Text Available Antecedentes y Objetivos. El músculo glúteo mayor es el más voluminoso y superficial de la región glútea, con forma cuadrilátera, dos inserciones diferentes, espesor variable en sus distintas zonas, y cubierto con diferentes fascias o aponeurosis. Realizamos un detallado estudio de la anatomía descriptiva y quirúrgica de dicho músculo para comparar cuál de las técnicas actuales utilizadas para el aumento glúteo con implantes es más segura y cuál proporciona mejores resultados. Material y método. Estudiamos 10 cadáveres frescos facilitados por el Instituto de Medicina Legal Regional Norte, y 10 cadáveres formolizados del anfiteatro de la Universidad Libre Seccional Barranquilla (Colombia, durante el período comprendido entre marzo de 2009 y febrero de 2010. Resultados. Determinamos que el músculo glúteo mayor, además de sus características anatómicas detalladas en los textos de anatomía descriptiva, está constituido por gruesos fascículos musculares paralelos y adyacentes unidos por fuertes tabiques o septos fibroaponeuróticos, del plano superficial al profundo. En el desarrollo del estudio encontramos un espacio anatómico intramuscular en el glúteo mayor, no descrito antes en las publicaciones de Cirugía Plástica ni en los textos de Anatomía más conocidos. Se presenta como una zona limpia, de aproximadamente 10 cm. de diámetro, con delicada aponeurosis muscular en su piso, sin la presencia de los tabiques fibroaponeuróticos interfasciculares habituales y exenta de estructuras vasculonerviosas importantes. Conclusiones. Describimos un nuevo espacio intramuscular en el glúteo mayor, que identificamos como Espacio Intramuscular de FROD, que consideramos de enorme potencial quirúrgico para la ejecución de las técnicas de aumento glúteo.

  15. The "G-Spot" Is Not a Structure Evident on Macroscopic Anatomic Dissection of the Vaginal Wall.

    Science.gov (United States)

    Hoag, Nathan; Keast, Janet R; O'Connell, Helen E

    2017-12-01

    Controversy exists in the literature regarding the presence or absence of an anatomic "G-spot." However, few studies have examined the detailed topographic or histologic anatomy of the putative G-spot location. To determine the anatomy of the anterior vaginal wall and present detailed, systematic, accessible findings from female cadaveric dissections to provide anatomic clarity with respect to this location. Systematic anatomic dissections were performed on 13 female cadavers (32-97 years old, 8 fixed and 5 fresh) to characterize the gross anatomy of the anterior vaginal wall. Digital photography was used to document dissections. Dissection preserved the anterior vaginal wall, urethra, and clitoris. In 9 cadavers, the vaginal epithelial layer was reflected to expose the underlying urethral wall and associated tissues. In 4 cadavers, the vaginal wall was left intact before preservation. Once photographed, 8 specimens were transversely sectioned for macroscopic inspection and histologic examination. The presence or absence of a macroscopic anatomic structure at detailed cadaveric pelvis dissection that corresponds to the previously described G-spot and gross anatomic description of the anterior vaginal wall. Deep to the lining epithelium of the anterior vaginal wall is the urethra. There is no macroscopic structure other than the urethra and vaginal wall lining in the location of the putative G-spot. Specifically, there is no apparent erectile or "spongy" tissue in the anterior vaginal wall, except where the urethra abuts the clitoris distally. The absence of an anatomic structure corresponding to the putative G-spot helps clarify the controversy on this subject. Limitations to this study include limited access to specimens immediately after death and potential for observational bias. In addition, age, medical history, and cause of death are not publishable for privacy reasons. However, it is one of the most thorough and complete anatomic evaluations documenting the

  16. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  17. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity

    DEFF Research Database (Denmark)

    Wendel, Sofie; Christian Fischer, Emil; Martinez, Virginia

    2016-01-01

    Background: Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay...... to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency.Conclusions: We have developed an inexpensive and easy read-out assay for surface display using...... nanobody: GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies...

  18. Reconfigurable Full-Page Braille Displays

    Science.gov (United States)

    Garner, H. Douglas

    1994-01-01

    Electrically actuated braille display cells of proposed type arrayed together to form full-page braille displays. Like other braille display cells, these provide changeable patterns of bumps driven by digitally recorded text stored on magnetic tapes or in solid-state electronic memories. Proposed cells contain electrorheological fluid. Viscosity of such fluid increases in strong electrostatic field.

  19. Extra-anatomical complications of antegrade double-J insertion

    Directory of Open Access Journals (Sweden)

    A R Rao

    2011-01-01

    Full Text Available Introduction: Insertion of a double-J (JJ stent is a common procedure often carried out in the retrograde route by the urologists and the antegrade route by the radiologists. Reported complications include stent migration, encrustation, and fracture. Extra-anatomic placement of an antegrade JJ stent is a rare but infrequently recognized complication. Materials and Methods: We performed a retrospective audit of 165 antegrade JJ stent insertions performed over three consecutive years by a single interventional radiologist. All renal units were hydronephrotic at the time of nephrostomy. All procedures were performed under local anaesthetic with antibiotic prophylaxis. Results: Antegrade stent insertion was carried out simultaneously at the time of nephrostomy in 55 of the 165 cases (33%. The remainder were inserted at a mean of 2 weeks following decompression. In five (3% patients, who had delayed antegrade stenting following nephrostomy, the procedure was complicated by silent ureteric perforation and an extra-anatomic placement of the stent. These complications had delayed manifestations, which included two retroperitoneal abscesses, a pelvic urinoma, a case each of ureterorectal fistula, and ureterovaginal fistula. Risk factors for ureteric perforation include previous pelvic malignancy, pelvic surgery, pelvic radiation, and a history of ureteric manipulation. Conclusion: Antegrade ureteric JJ stenting is a procedure not without complications. Extra-anatomic placement of the antegrade stent is a hitherto the infrequently reported complication but needs a high index of suspicion to be diagnosed. Risk factors for ureteric perforation at the time of stent insertion have to be considered to prevent this potential complication.

  20. Designing learning spaces for interprofessional education in the anatomical sciences.

    Science.gov (United States)

    Cleveland, Benjamin; Kvan, Thomas

    2015-01-01

    This article explores connections between interprofessional education (IPE) models and the design of learning spaces for undergraduate and graduate education in the anatomical sciences and other professional preparation. The authors argue that for IPE models to be successful and sustained they must be embodied in the environment in which interprofessional learning occurs. To elaborate these arguments, two exemplar tertiary education facilities are discussed: the Charles Perkins Centre at the University of Sydney for science education and research, and Victoria University's Interprofessional Clinic in Wyndham for undergraduate IPE in health care. Backed by well-conceived curriculum and pedagogical models, the architectures of these facilities embody the educational visions, methods, and practices they were designed to support. Subsequently, the article discusses the spatial implications of curriculum and pedagogical change in the teaching of the anatomical sciences and explores how architecture might further the development of IPE models in the field. In conclusion, it is argued that learning spaces should be designed and developed (socially) with the expressed intention of supporting collaborative IPE models in health education settings, including those in the anatomical sciences. © 2015 American Association of Anatomists.

  1. Hemispheric Asymmetry of Human Brain Anatomical Network Revealed by Diffusion Tensor Tractography

    Directory of Open Access Journals (Sweden)

    Ni Shu

    2015-01-01

    Full Text Available The topological architecture of the cerebral anatomical network reflects the structural organization of the human brain. Recently, topological measures based on graph theory have provided new approaches for quantifying large-scale anatomical networks. However, few studies have investigated the hemispheric asymmetries of the human brain from the perspective of the network model, and little is known about the asymmetries of the connection patterns of brain regions, which may reflect the functional integration and interaction between different regions. Here, we utilized diffusion tensor imaging to construct binary anatomical networks for 72 right-handed healthy adult subjects. We established the existence of structural connections between any pair of the 90 cortical and subcortical regions using deterministic tractography. To investigate the hemispheric asymmetries of the brain, statistical analyses were performed to reveal the brain regions with significant differences between bilateral topological properties, such as degree of connectivity, characteristic path length, and betweenness centrality. Furthermore, local structural connections were also investigated to examine the local asymmetries of some specific white matter tracts. From the perspective of both the global and local connection patterns, we identified the brain regions with hemispheric asymmetries. Combined with the previous studies, we suggested that the topological asymmetries in the anatomical network may reflect the functional lateralization of the human brain.

  2. Anatomic atlas for computed tomography in the mesaticephalic dog: head and neck

    International Nuclear Information System (INIS)

    George, T.F. II; Smallwood, J.E.

    1992-01-01

    The purpose of this study was to produce a comprehensive anatomic atlas of CT anatomy of the dog for use by veterinary radiologists, clinicians, and surgeons. Whole-body CT images of two mature beagle dogs were made with the dogs supported in sternal recumbency and using a slice thickness of 13 mm. The head was scanned using high-resolution imaging with a slice thickness of 8 mm. At the end of the CT session, each dog was euthanized, and while carefully maintaining the same position, the body was placed in a walk-in freezer until completely frozen. The body was then sectioned at 13-mm (head at 8-mm) intervals, with the cuts matched as closely as possible to the CT slices. The forzen sections were cleaned, photographed, and radiographed using xeroradiography. Each CT image was studied and compared with its corresponding xeroradiograph and anatomic section to assist in the accurate identification of specific structures. Intact, sagittally sectioned, and disarticulated dog skulls were used as reference models. Clinically relevant anatomic structures were identified and labeled in the three corresponding photographs (CT image, xeroradiograph, and anatomic section). In this paper, the CT anatomy of the head and neck of the mesaticephalic dog is presented

  3. Femoral rotational asymmetry is a common anatomical variant.

    Science.gov (United States)

    Newman, Christopher R; Walter, William L; Talbot, Simon

    2018-05-01

    The sulcus line (SL) is a three-dimensional landmark that corrects for individual variation in the coronal alignment of the trochlear groove in contrast to the traditional Whiteside's line (WL). Femoral rotational asymmetry (FRA) is an anatomical variation in which the posterior condyles and trochlear groove are not perpendicular to each other. This study aims to measure the SL and assess its reliability relative to WL, in addition to measuring and classifying the FRA. A retrospective analysis of a series of 191 CT scans of nonarthritic knees was performed. Measurements were taken of rotational landmarks in three-dimensional reconstructions. The variability and outlier rate of SL was less than WL (P  0.05), however it decreased the rate of change of the rotational alignment of the trochlear groove between the native knee and the prosthetic knee from 31% to 5% (P 5° in 56/191 (29%) of cases. The SL technique is more accurate than WL for determining the rotational alignment of the trochlear groove. Nonarthritic femora have a high rate of rotational asymmetry. Identifying and classifying FRA in individual cases allows the femoral component to be inserted in a position which gives the best possible match to both the native posterior condyles and trochlear groove. Clin. Anat. 31:551-559, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  4. Display-management system for MFTF

    International Nuclear Information System (INIS)

    Nelson, D.O.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is controlled by 65 local control microcomputers which are supervised by a local network of nine 32-bit minicomputers. Associated with seven of the nine computers are state-of-the-art graphics devices, each with extensive local processing capability. These devices provide the means for an operator to interact with the control software running on the minicomputers. It is critical that the information the operator views accurately reflects the current state of the experiment. This information is integrated into dynamically changing pictures called displays. The primary organizational component of the display system is the software-addressable segment. The segments created by the display creation software are managed by display managers associated with each graphics device. Each display manager uses sophisticated storage management mechanisms to keep the proper segments resident in the local graphics device storage

  5. Environmental impact on morphological and anatomical structure of ...

    African Journals Online (AJOL)

    Morphological and anatomical structure of Tansy (Tanacetum vulgare L.) from two specific locations in one town, depending on environmental conditions, were carried out: anthropogenic Ada Huja (polluted zone) and non anthropogenic Topcider park (unpolluted). Study included the diferences in the structure of leaves, ...

  6. Data display with the Q system

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1979-01-01

    The Q data-acquisition system for PDP-11 mini-computers at the Clinton P. Anderson Meson Physics Facility (LAMPF) provides experimenters with basic tools for on-line data display. Tasks are available to plot one- and two-parameter histograms on Tektronix 4000 series storage-tube terminals. The histograms to be displayed and the display format may be selected with simple keyboard commands. A task is also available to create and display live two-parameter scatter plots for any acquired or calculated quantities. Other tasks in the system manage the display data base, list display parameters and histogram contents on hardcopy devices, and save core histograms on disk or tape for off-line analysis. 8 figures

  7. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity.

    Science.gov (United States)

    Wendel, Sofie; Fischer, Emil C; Martínez, Virginia; Seppälä, Susanna; Nørholm, Morten H H

    2016-05-03

    Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay for evaluating and developing surface display systems is missing. Using a single domain antibody (also called nanobody) with high affinity for green fluorescent protein (GFP), we constructed a system that allows for fast, fluorescence-based detection of displayed proteins. The outer membrane hybrid protein LppOmpA and the autotransporter C-IgAP exposed the nanobody on the surface of Escherichia coli with very different efficiency. Both anchors were capable of functionally displaying the enzyme Chitinase A as a fusion with the nanobody, and this considerably increased expression levels compared to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency. We have developed an inexpensive and easy read-out assay for surface display using nanobody:GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies on the mechanism of protein transport to the surface of living cells, as well as the optimisation of applications in industrial biotech.

  8. A stem anatomical investigation of Cuscuta L. (Convolvulaceae species in Khorassan provinces

    Directory of Open Access Journals (Sweden)

    Jamil Vaezi

    2014-04-01

    C. epithymum, C. pedicellata, C. lehmanniana var. lehmanniana and C. babylonica var. babylonica distributed in Khorassan provinces were investigated using the blue toluidine staining. Cross sections were provided by hand. Results showed that anatomical characters including stem diameter, position and distribution of vessels, number and size of vessels and number of parenchymatous layers were effective traits to taxonomically separate the species under study. Furthermore, the anatomical relationship between parasite and its host plant was examined.

  9. Conceptual Design of Industrial Process Displays

    DEFF Research Database (Denmark)

    Pedersen, C.R.; Lind, Morten

    1999-01-01

    discusses aspects of process display design taking into account both the designer's and the operator's points of view. Three aspects are emphasized: the operator tasks, the display content and the display form. The distinction between these three aspects is the basis for proposing an outline for a display......Today, process displays used in industry are often designed on the basis of piping and instrumentation diagrams without any method of ensuring that the needs of the operators are fulfilled. Therefore, a method for a systematic approach to the design of process displays is needed. This paper...... by a simple example from a plant with batch processes. Later the method is applied to develop a supervisory display for a condenser system in a nuclear power plant. The differences between the continuous plant domain of power production and the batch processes from the example are analysed and broad...

  10. Ethnic variability in adiposity and cardiovascular risk: the variable disease selection hypothesis.

    Science.gov (United States)

    Wells, Jonathan C K

    2009-02-01

    Evidence increasingly suggests that ethnic differences in cardiovascular risk are partly mediated by adipose tissue biology, which refers to the regional distribution of adipose tissue and its differential metabolic activity. This paper proposes a novel evolutionary hypothesis for ethnic genetic variability in adipose tissue biology. Whereas medical interest focuses on the harmful effect of excess fat, the value of adipose tissue is greatest during chronic energy insufficiency. Following Neel's influential paper on the thrifty genotype, proposed to have been favoured by exposure to cycles of feast and famine, much effort has been devoted to searching for genetic markers of 'thrifty metabolism'. However, whether famine-induced starvation was the primary selective pressure on adipose tissue biology has been questioned, while the notion that fat primarily represents a buffer against starvation appears inconsistent with historical records of mortality during famines. This paper reviews evidence for the role played by adipose tissue in immune function and proposes that adipose tissue biology responds to selective pressures acting through infectious disease. Different diseases activate the immune system in different ways and induce different metabolic costs. It is hypothesized that exposure to different infectious disease burdens has favoured ethnic genetic variability in the anatomical location of, and metabolic profile of, adipose tissue depots.

  11. Implementation of the Business Process Modelling Notation (BPMN) in the modelling of anatomic pathology processes.

    Science.gov (United States)

    Rojo, Marcial García; Rolón, Elvira; Calahorra, Luis; García, Felix Oscar; Sánchez, Rosario Paloma; Ruiz, Francisco; Ballester, Nieves; Armenteros, María; Rodríguez, Teresa; Espartero, Rafael Martín

    2008-07-15

    Process orientation is one of the essential elements of quality management systems, including those in use in healthcare. Business processes in hospitals are very complex and variable. BPMN (Business Process Modelling Notation) is a user-oriented language specifically designed for the modelling of business (organizational) processes. Previous experiences of the use of this notation in the processes modelling within the Pathology in Spain or another country are not known. We present our experience in the elaboration of the conceptual models of Pathology processes, as part of a global programmed surgical patient process, using BPMN. With the objective of analyzing the use of BPMN notation in real cases, a multidisciplinary work group was created, including software engineers from the Dep. of Technologies and Information Systems from the University of Castilla-La Mancha and health professionals and administrative staff from the Hospital General de Ciudad Real. The work in collaboration was carried out in six phases: informative meetings, intensive training, process selection, definition of the work method, process describing by hospital experts, and process modelling. The modelling of the processes of Anatomic Pathology is presented using BPMN. The presented subprocesses are those corresponding to the surgical pathology examination of the samples coming from operating theatre, including the planning and realization of frozen studies. The modelling of Anatomic Pathology subprocesses has allowed the creation of an understandable graphical model, where management and improvements are more easily implemented by health professionals.

  12. Anatomical guidance for functional near-infrared spectroscopy: AtlasViewer tutorial.

    Science.gov (United States)

    Aasted, Christopher M; Yücel, Meryem A; Cooper, Robert J; Dubb, Jay; Tsuzuki, Daisuke; Becerra, Lino; Petkov, Mike P; Borsook, David; Dan, Ippeita; Boas, David A

    2015-04-01

    Functional near-infrared spectroscopy (fNIRS) is an optical imaging method that is used to noninvasively measure cerebral hemoglobin concentration changes induced by brain activation. Using structural guidance in fNIRS research enhances interpretation of results and facilitates making comparisons between studies. AtlasViewer is an open-source software package we have developed that incorporates multiple spatial registration tools to enable structural guidance in the interpretation of fNIRS studies. We introduce the reader to the layout of the AtlasViewer graphical user interface, the folder structure, and user files required in the creation of fNIRS probes containing sources and detectors registered to desired locations on the head, evaluating probe fabrication error and intersubject probe placement variability, and different procedures for estimating measurement sensitivity to different brain regions as well as image reconstruction performance. Further, we detail how AtlasViewer provides a generic head atlas for guiding interpretation of fNIRS results, but also permits users to provide subject-specific head anatomies to interpret their results. We anticipate that AtlasViewer will be a valuable tool in improving the anatomical interpretation of fNIRS studies.

  13. Does EMS Perceived Anatomic Injury Predict Trauma Center Need?

    Science.gov (United States)

    Lerner, E. Brooke; Roberts, Jennifer; Guse, Clare E.; Shah, Manish N.; Swor, Robert; Cushman, Jeremy T.; Blatt, Alan; Jurkovich, Gregory J.; Brasel, Karen

    2013-01-01

    Objective Our objective was to determine the predictive value of the anatomic step of the 2011 Field Triage Decision Scheme for identifying trauma center need. Methods EMS providers caring for injured adults transported to regional trauma centers in 3 midsized communities were interviewed over two years. Patients were included, regardless of injury severity, if they were at least 18 years old and were transported by EMS with a mechanism of injury that was an assault, motor vehicle or motorcycle crash, fall, or pedestrian or bicyclist struck. The interview was conducted upon ED arrival and collected physiologic condition and anatomic injury data. Patients who met the physiologic criteria were excluded. Trauma center need was defined as non-orthopedic surgery within 24 hours, intensive care unit admission, or death prior to hospital discharge. Data were analyzed by calculating descriptive statistics including positive likelihood ratios (+LR) with 95% confidence intervals. Results 11,892 interviews were conducted. One was excluded because of missing outcome data and 1,274 were excluded because they met the physiologic step. EMS providers identified 1,167 cases that met the anatomic criteria, of which 307 (26%) needed the resources of a trauma center (38% sensitivity, 91% specificity, +LR 4.4; CI: 3.9 - 4.9). Criteria with a +LR ≥5 were flail chest (9.0; CI: 4.1 - 19.4), paralysis (6.8; CI: 4.2 - 11.2), two or more long bone fractures (6.3; CI: 4.5 - 8.9), and amputation (6.1; CI: 1.5 - 24.4). Criteria with a +LR >2 and <5 were penetrating injury (4.8; CI: 4.2 - 5.6), and skull fracture (4.8; CI: 3.0 - 7.7). Only pelvic fracture (1.9; CI: 1.3 - 2.9) had a +LR less than 2. Conclusions The anatomic step of the Field Triage Guidelines as determined by EMS providers is a reasonable tool for determining trauma center need. Use of EMS perceived pelvic fracture as an indicator for trauma center need should be re-evaluated. PMID:23627418

  14. Improvements in data display

    International Nuclear Information System (INIS)

    Ellis, G.W.

    1979-01-01

    An analog signal processor is described in this patent for connecting a source of analog signals to a cathode ray tube display in order to extend the dynamic range of the display. This has important applications in the field of computerised X-ray tomography since significant medical information, such as tumours in soft tissue, is often represented by minimal level changes in image density. Cathode ray tube displays are limited to approximately 15 intensity levels. Thus if both strong and weak absorption of the X-rays occurs, the dynamic range of the transmitted signals will be too large to permit small variations to be examined directly on a cathode ray display. Present tomographic image reconstruction methods are capable of quantising X-ray absorption density measurements into 256 or more distinct levels and a description is given of the electronics which enables the upper and lower range of intensity levels to be independently set and continuously varied. (UK)

  15. Anatomical Modularity of Verbal Working Memory? Functional Anatomical Evidence from a Famous Patient with Short-Term Memory Deficits

    Directory of Open Access Journals (Sweden)

    Eraldo Paulesu

    2017-05-01

    Full Text Available Cognitive skills are the emergent property of distributed neural networks. The distributed nature of these networks does not necessarily imply a lack of specialization of the individual brain structures involved. However, it remains questionable whether discrete aspects of high-level behavior might be the result of localized brain activity of individual nodes within such networks. The phonological loop of working memory, with its simplicity, seems ideally suited for testing this possibility. Central to the development of the phonological loop model has been the description of patients with focal lesions and specific deficits. As much as the detailed description of their behavior has served to refine the phonological loop model, a classical anatomoclinical correlation approach with such cases falls short in telling whether the observed behavior is based on the functions of a neural system resembling that seen in normal subjects challenged with phonological loop tasks or whether different systems have taken over. This is a crucial issue for the cross correlation of normal cognition, normal physiology, and cognitive neuropsychology. Here we describe the functional anatomical patterns of JB, a historical patient originally described by Warrington et al. (1971, a patient with a left temporo-parietal lesion and selective short phonological store deficit. JB was studied with the H215O PET activation technique during a rhyming task, which primarily depends on the rehearsal system of the phonological loop. No residual function was observed in the left temporo-parietal junction, a region previously associated with the phonological buffer of working memory. However, Broca's area, the major counterpart of the rehearsal system, was the major site of activation during the rhyming task. Specific and autonomous activation of Broca's area in the absence of afferent inputs from the other major anatomical component of the phonological loop shows that a certain

  16. Anatomical landmarks of radical prostatecomy.

    Science.gov (United States)

    Stolzenburg, Jens-Uwe; Schwalenberg, Thilo; Horn, Lars-Christian; Neuhaus, Jochen; Constantinides, Costantinos; Liatsikos, Evangelos N

    2007-03-01

    In the present study, we review current literature and based on our experience, we present the anatomical landmarks of open and laparoscopic/endoscopic radical prostatectomy. A thorough literature search was performed with the Medline database on the anatomy and the nomenclature of the structures surrounding the prostate gland. The correct handling of puboprostatic ligaments, external urethral sphincter, prostatic fascias and neurovascular bundle is necessary for avoiding malfunction of the urogenital system after radical prostatectomy. When evaluating new prostatectomy techniques, we should always take into account both clinical and final oncological outcomes. The present review adds further knowledge to the existing "postprostatectomy anatomical hazard" debate. It emphasizes upon the role of the puboprostatic ligaments and the course of the external urethral sphincter for urinary continence. When performing an intrafascial nerve sparing prostatectomy most urologists tend to approach as close to the prostatic capsula as possible, even though there is no concurrence regarding the nomenclature of the surrounding fascias and the course of the actual neurovascular bundles. After completion of an intrafascial technique the specimen does not contain any periprostatic tissue and thus the detection of pT3a disease is not feasible. This especially becomes problematic if the tumour reaches the resection margin. Nerve sparing open and laparoscopic radical prostatectomy should aim in maintaining sexual function, recuperating early continence after surgery, without hindering the final oncological outcome to the procedure. Despite the different approaches for radical prostatectomy the key for better results is the understanding of the anatomy of the bladder neck and the urethra.

  17. Dissection of lung parenchyma using electrocautery is a safe and acceptable method for anatomical sublobar resection

    OpenAIRE

    Ohtsuka, Takashi; Goto, Taichiro; Anraku, Masaki; Kohno, Mitsutomo; Izumi, Yotaro; Horinouchi, Hirohisa; Nomori, Hiroaki

    2012-01-01

    Abstract Background Anatomic sublobar resection is being assessed as a substitute to lobectomy for primary lung cancers. However, persistent air leak after anatomic sublobar resection is prevalent and increasing surgical morbidity and costs. The use of electrocautery is being popularized recently in anatomic sublobar resection. We have retrospectively evaluated the safety and efficacy of intersegmental plane dissection using electrocautery. Methods Between April 2009 to September 2010, 47 pat...

  18. Prototype particulate stack sampler with single-cut nozzle and microcomputer calculating/display system

    International Nuclear Information System (INIS)

    Eler, J.C.; Littlefield, L.G.; Tillery, M.I.

    1979-01-01

    A prototype particulate stack sampler (PPSS) has been developed to improve on the existing EPA Method 5 sampling apparatus. Its primary features are (1) higher sampling rate (56 1/min); (2) display (on demand) of all required variables and calculated values by a microcomputer-based calculating and display system; (3) continuous stack gas moisture determination; (4) a virtual impactor nozzle with 3 μm mass median diameter cutpoint which collects fine and coarse particle fractions on separate glass fiber filters; (5) a variable-area inlet to maintain isokinetic sampling conditions; and (6) conversion to stainless steel components from the glass specified by EPA Method 5. The basic sampling techniques of EPA Method 5 have been retained; however, versatility in the form of optional in-stack filters and general modernization of the stack sampler have been provided in the prototype design. Laboratory testing with monodisperse dye aerosols has shown the present variable inlet, virtual impactor nozzle to have a collection efficiency which is less than 77% and significant wall losses. This is primarily due to lack of symmetry in this rectangular jet impactor and short transition lengths dictated by physical design constraints (required passage of the nozzle through a 7.6 cm (3 in) diameter stack port). Electronic components have shown acceptable service in laboratory testing although no field testing of the prototype under a broad range of temperature, humidity, and SO 2 concentration has been undertaken

  19. Variable stars in metal-rich globular clusters. IV. Long-period variables in NGC 6496

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mohamad A. [Astronomisches Rechen-Institut, Zentrum für Astronomie der Universität Heidelberg, Mönchhofstr. 12-14, D-69120 Heidelberg (Germany); Layden, Andrew C.; Guldenschuh, Katherine A. [Physics and Astronomy Department, Bowling Green State University, Bowling Green, OH 43403 (United States); Reichart, D. E.; Ivarsen, K. M.; Haislip, J. B.; Nysewander, M. C.; LaCluyze, A. P. [Department of Physics and Astronomy, University of North Carolina, Chapel Hill, NC 27599 (United States); Welch, Douglas L., E-mail: mabbas@ari.uni-heidelberg.de, E-mail: laydena@bgsu.edu [Department of Physics and Astronomy, McMaster University, Hamilton, Ontario, L8 S 4M1 (Canada)

    2015-02-01

    We present VI-band photometry for stars in the metal-rich globular cluster NGC 6496. Our time-series data were cadenced to search for long-period variables (LPVs) over a span of nearly two years, and our variability search yielded the discovery of 13 new variable stars, of which 6 are LPVs, 2 are suspected LPVs, and 5 are short-period eclipsing binaries. An additional star was found in the ASAS database, and we clarify its type and period. We argue that all of the eclipsing binaries are field stars, while five to six of the LPVs are members of NGC 6496. We compare the period–luminosity distribution of these LPVs with those of LPVs in the Large Magellanic Cloud and 47 Tucanae, and with theoretical pulsation models. We also present a VI color–magnitude diagram, display the evolutionary states of the variables, and match isochrones to determine a reddening of E(B−V)= 0.21±0.02 mag and apparent distance modulus of 15.60±0.15 mag.

  20. Teaching of anatomical sciences: A blended learning approach.

    Science.gov (United States)

    Khalil, Mohammed K; Abdel Meguid, Eiman M; Elkhider, Ihsan A

    2018-04-01

    Blended learning is the integration of different learning approaches, new technologies, and activities that combine traditional face-to-face teaching methods with authentic online methodologies. Although advances in educational technology have helped to expand the selection of different pedagogies, the teaching of anatomical sciences has been challenged by implementation difficulties and other limitations. These challenges are reported to include lack of time, costs, and lack of qualified teachers. Easy access to online information and advances in technology make it possible to resolve these limitations by adopting blended learning approaches. Blended learning strategies have been shown to improve students' academic performance, motivation, attitude, and satisfaction, and to provide convenient and flexible learning. Implementation of blended learning strategies has also proved cost effective. This article provides a theoretical foundation for blended learning and proposes a validated framework for the design of blended learning activities in the teaching and learning of anatomical sciences. Clin. Anat. 31:323-329, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  1. Helmet-Mounted Display Design Guide

    Science.gov (United States)

    1997-11-03

    on openStack create menu "CSHMD" set the menuitems of "CSHMD" to "(Main Menu; References;-; Definitions;Display Criteria;Display Formats;Display Modes...34Macintosh" then put ":" into dirSep else put "V’ into dirSep put stackPathO&"Resource"&dirSep into gResPath put 0 into gXRef end openStack on

  2. Ruggedized Full-Color Flexible OLED Display

    National Research Council Canada - National Science Library

    Hack, Michael

    2003-01-01

    .... The team comprised Universal Display Corporation, Princeton University, the University of Southern California, Penn State University, L3 Displays and Vitex Systems, and was led by Universal Display Corporation (PI: Michael Hack...

  3. An interactive three-dimensional virtual body structures system for anatomical training over the internet.

    Science.gov (United States)

    Temkin, Bharti; Acosta, Eric; Malvankar, Ameya; Vaidyanath, Sreeram

    2006-04-01

    The Visible Human digital datasets make it possible to develop computer-based anatomical training systems that use virtual anatomical models (virtual body structures-VBS). Medical schools are combining these virtual training systems and classical anatomy teaching methods that use labeled images and cadaver dissection. In this paper we present a customizable web-based three-dimensional anatomy training system, W3D-VBS. W3D-VBS uses National Library of Medicine's (NLM) Visible Human Male datasets to interactively locate, explore, select, extract, highlight, label, and visualize, realistic 2D (using axial, coronal, and sagittal views) and 3D virtual structures. A real-time self-guided virtual tour of the entire body is designed to provide detailed anatomical information about structures, substructures, and proximal structures. The system thus facilitates learning of visuospatial relationships at a level of detail that may not be possible by any other means. The use of volumetric structures allows for repeated real-time virtual dissections, from any angle, at the convenience of the user. Volumetric (3D) virtual dissections are performed by adding, removing, highlighting, and labeling individual structures (and/or entire anatomical systems). The resultant virtual explorations (consisting of anatomical 2D/3D illustrations and animations), with user selected highlighting colors and label positions, can be saved and used for generating lesson plans and evaluation systems. Tracking users' progress using the evaluation system helps customize the curriculum, making W3D-VBS a powerful learning tool. Our plan is to incorporate other Visible Human segmented datasets, especially datasets with higher resolutions, that make it possible to include finer anatomical structures such as nerves and small vessels. (c) 2006 Wiley-Liss, Inc.

  4. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Radionuclide dosimetry must, by its nature, define tissue irradiation in terms of mean exposure in a population of a statistically acceptable size. In the daily practice of clinical nuclear medicine there are, however, quite large variations in the biodistribution of tracers and thus in resulting radiation doses. Age is a variable, particularly in respect of bone-seeking tracers. Sex imposes variations in radiation dose on account of the differing anatomical configurations of the gonads. Breast uptake and excretion of certain tracers in women are additional variables. Activity and occupation are occasional variables. Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggest that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  5. Evaluation of stereoscopic medical video content on an autostereoscopic display for undergraduate medical education

    Science.gov (United States)

    Ilgner, Justus F. R.; Kawai, Takashi; Shibata, Takashi; Yamazoe, Takashi; Westhofen, Martin

    2006-02-01

    Introduction: An increasing number of surgical procedures are performed in a microsurgical and minimally-invasive fashion. However, the performance of surgery, its possibilities and limitations become difficult to teach. Stereoscopic video has evolved from a complex production process and expensive hardware towards rapid editing of video streams with standard and HDTV resolution which can be displayed on portable equipment. This study evaluates the usefulness of stereoscopic video in teaching undergraduate medical students. Material and methods: From an earlier study we chose two clips each of three different microsurgical operations (tympanoplasty type III of the ear, endonasal operation of the paranasal sinuses and laser chordectomy for carcinoma of the larynx). This material was added by 23 clips of a cochlear implantation, which was specifically edited for a portable computer with an autostereoscopic display (PC-RD1-3D, SHARP Corp., Japan). The recording and synchronization of left and right image was performed at the University Hospital Aachen. The footage was edited stereoscopically at the Waseda University by means of our original software for non-linear editing of stereoscopic 3-D movies. Then the material was converted into the streaming 3-D video format. The purpose of the conversion was to present the video clips by a file type that does not depend on a television signal such as PAL or NTSC. 25 4th year medical students who participated in the general ENT course at Aachen University Hospital were asked to estimate depth clues within the six video clips plus cochlear implantation clips. Another 25 4th year students who were shown the material monoscopically on a conventional laptop served as control. Results: All participants noted that the additional depth information helped with understanding the relation of anatomical structures, even though none had hands-on experience with Ear, Nose and Throat operations before or during the course. The monoscopic

  6. Investigations of Anatomical Variations of the Thorax and Heart, and Anatomical Knowledge for First Year Medical Dental and Podiatry Students

    Science.gov (United States)

    Verenna, Anne-Marie

    2013-01-01

    The universal presence of anatomy in healthcare professions is undeniable. It is a cornerstone to each of the clinical and basic sciences. Therefore, further expansion of current anatomical knowledge and effective methods to teach anatomy is essential. In this work, the relationship of the dorsal scapular artery with the trunks of the brachial…

  7. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  8. [Analysis of anatomical pieces preservation with polyester resin for human anatomy study].

    Science.gov (United States)

    de Oliveira, Ítalo Martins; Mindêllo, Marcela Maria Aguiar; Martins, Yasmin de Oliveira; da Silva Filho, Antônio Ribeiro

    2013-01-01

    To evaluate the use of polyester resin in preserving anatomical specimens for the study of human anatomy. We used 150 anatomical specimens, comprised of unfixed (fresh), fixed in 10% formalin and vascular casts of organs injected with vinyl acetate and polyester resin. The solution used consisted of polyester resin with the diluent styrene monomer and catalyst (peroxol). After embedding in this solution, models in transparent resin were obtained, allowing full observation of structures and conservation of the specimens used. upon evaluation of the specimens, we observed a high degree of transparency, which promoted a complete visualization of structures with perfect preservation of the anatomy. The average time for the completion of the embedding was 48 hours. Only 14 specimens (9.3%) were lost during the preparation. Polyester resin can be used for preserving anatomical specimens for teaching human anatomy in a practical, aesthetic and durable way.

  9. Analysis of anatomical variations of the main arteries branching from the abdominal aorta, with 64-detector computed tomography

    International Nuclear Information System (INIS)

    Kornafel, O.; Baran, B.; Pawlikowska, I.; Laszczynski, P.; Guzinski, M.; Sasiadek, M.

    2010-01-01

    Background: Great variability in the vasculature of the abdominal organs makes the pre-operative evaluation of arterial anatomical conditions extremely important and helpful. The aim of our study was to establish the prevalence of anatomical variations of the arteries branching from the abdominal aorta and to compare the results with the ones presented in the literature. Material/Methods: The material included computed tomography angiographies (CTA) of 201 patients (91 women and 110 men) performed between September 2007 and December 2008. The CTA examinations were conducted with a 64-detector CT scanner at the Department of Radiology of University Hospital in Wroclaw. Images were obtained during the arterial phase and were analyzed for the presence of potential anomalies of the branches of the abdominal aorta. Results: In 88 patients (43.8%), there were anatomical variations of the arteries branching from the abdominal aorta. Variations of the renal arteries were observed in 83 (41.3%) patients, anomalies of the celiac trunk in 9 patients (4.5%), including variations of the superior mesenteric artery in 4 (2%) patients. No anatomical anomalies of the inferior mesenteric artery were shown in this study. The most frequent anomaly of the renal vasculature was the presence of at least one additional renal artery, observed in 65 (32.3%) patients. This concerned the inferior renal polar artery mainly - in 30 (14.9%) patients. Presence of bilateral additional renal arteries was visualized in 10% (20/201) of the cases. The most frequent anomalies of the celiac trunk were the celiacmesenteric trunk (in 3 patients - 1.5%) and the hepatosplenic trunk (in 3 patients - 1.5%). The celiac-mesenteric trunk was also the most frequent variation of the superior mesenteric artery in our material. Conclusions: A large part of population - 43.8% of our patients - demonstrated variations of arteries branching from the abdominal aorta. The anomalies were significantly more often found

  10. Anatomic atlas for computed tomography in the mesaticephalic dog: caudal abdomen and pelvis

    International Nuclear Information System (INIS)

    Smallwood, J.E.; George, T. II.

    1993-01-01

    The purpose of this study was to produce a comprehensive anatomic atlas of CT anatomy of the dog for use by veterinary radiologists, clinicians, and surgeons. Whole-body CT images of two mature beagle dogs were made with the dogs supported in sternal recumbency and using a slice thickness of 13 mm. At the end of the CT session, each dog was euthanized, and while carefully maintaining the same position, the body was frozen. The body was then sectioned at 13-mm intervals, with the cuts matched as closely as possible to the CT slices. The frozen sections were cleaned, photographed, and radiographed using xeroradiography. Each CT image was studied and compared with its corresponding xeroradiograph and anatomic section to assist in the accurate identification of specific structures. Clinically relevant anatomic structures were identified and labeled in the three corresponding photographs (CT image, xeroradiograph, and anatomic section). In previous papers, the head and neck, and the thorax and cranial abdomen of the mesaticephalic (beagle) dog were presented. In this paper, the caudal part of the abdomen and pelvis of the bitch and male dog are presented

  11. Basics of Antibody Phage Display Technology.

    Science.gov (United States)

    Ledsgaard, Line; Kilstrup, Mogens; Karatt-Vellatt, Aneesh; McCafferty, John; Laustsen, Andreas H

    2018-06-09

    Antibody discovery has become increasingly important in almost all areas of modern medicine. Different antibody discovery approaches exist, but one that has gained increasing interest in the field of toxinology and antivenom research is phage display technology. In this review, the lifecycle of the M13 phage and the basics of phage display technology are presented together with important factors influencing the success rates of phage display experiments. Moreover, the pros and cons of different antigen display methods and the use of naïve versus immunized phage display antibody libraries is discussed, and selected examples from the field of antivenom research are highlighted. This review thus provides in-depth knowledge on the principles and use of phage display technology with a special focus on discovery of antibodies that target animal toxins.

  12. Longitudinal retention of anatomical knowledge in second-year medical students.

    Science.gov (United States)

    Doomernik, Denise E; van Goor, Harry; Kooloos, Jan G M; Ten Broek, Richard P

    2017-06-01

    The Radboud University Medical Center has a problem-based, learner-oriented, horizontally, and vertically integrated medical curriculum. Anatomists and clinicians have noticed students' decreasing anatomical knowledge and the disability to apply knowledge in diagnostic reasoning and problem solving. In a longitudinal cohort, the retention of anatomical knowledge gained during the first year of medical school among second-year medical students was assessed. In May 2011, 346 medical students applied for the second-year gastro-intestinal (GI) tract course. The students were asked to participate in a reexamination of a selection of anatomical questions of an examination from October 2009. The examination consisted of a clinical anatomy case scenario and two computed tomography (CT) images of thorax and abdomen in an extended matching format. A total of 165 students were included for analysis. In 2011, students scored significantly lower for the anatomy examination compared to 2009 with a decline in overall examination score of 14.7% (±11.7%). Decrease in knowledge was higher in the radiological questions, compared to the clinical anatomy cases 17.5% (±13.6%) vs. 7.9% (±10.0%), respectively, d = 5.17. In both years, male students scored slightly better compared to female students, and decline of knowledge seems somewhat lower in male students (13.1% (±11.1%) vs. 15.5% (±12.0%), respectively), d = -0.21. Anatomical knowledge in the problem-oriented horizontal and vertical integrated medical curriculum, declined by approximately 15% 1.5 year after the initial anatomy course. The loss of knowledge in the present study is relative small compared to previous studies. Anat Sci Educ 10: 242-248. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  13. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  14. Anatomical segmentation of the human medial prefrontal cortex

    NARCIS (Netherlands)

    Corcoles-Parada, M.; Müller, N.C.J.; Ubero, M.; Serrano-Del-Pueblo, V.M.; Mansilla, F.; Marcos-Rabal, P.; Artacho-Perula, E.; Dresler, M.; Insausti, R.; Fernandez, G.; Munoz-Lopez, M.

    2017-01-01

    The medial prefrontal areas 32, 24, 14, and 25 (mPFC) form part of the limbic memory system, but little is known about their functional specialization in humans. To add anatomical precision to structural and functional magnetic resonance imaging (MRI) data, we aimed to identify these mPFC subareas

  15. Peroneal nerve injury in three patients with knee trauma: MR imaging and correlation with anatomic findings in volunteers and anatomic specimens

    Energy Technology Data Exchange (ETDEWEB)

    Trappeniers, Laurence; Osteaux, Michel [Department of Radiology, Vrije Universiteit Brussels, Brussels (Belgium); De Maeseneer, Michel [Department of Radiology, Vrije Universiteit Brussels, Brussels (Belgium); Department of Radiology, AZ VUB, Laarbeeklaan 101, 1090, Jette (Belgium); Van Roy, Peter [Department of Experimental Anatomy, Vrije Universiteit Brussels, Brussels (Belgium); Chaskis, Christo [Department of Neurosurgery, Vrije Universiteit Brussels, Brussels (Belgium)

    2003-07-01

    The aim of this article is to report on three patients with injuries of the peroneal nerve along the posterolateral aspect of the knee. Injuries in this area are less common than the injuries occurring at the level of the fibular head. In this article we report on three patients with posterolateral knee trauma who had peroneal nerve dysfunction. To better understand the precise location of the nerve on MR images, we performed MR imaging in five volunteers, and studied the position of the nerve on anatomic dissection (n=1) and anatomic slices (n=1). The common peroneal nerve is easily depicted on MR images and has a typical location along the posterior margin of the biceps tendon. Non-visualisation of the peroneal nerve at the posterolateral aspect of the knee, as seen on MR images, is consistent with nerve injury. Scar tissue at the posterolateral aspect of the knee indicates injury of this specific area, and involvement of the peroneal nerve is likely. (orig.)

  16. Display rules versus display autonomy: emotion regulation, emotional exhaustion, and task performance in a call center simulation.

    Science.gov (United States)

    Goldberg, Lori Sideman; Grandey, Alicia A

    2007-07-01

    "Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA

  17. Three-dimensional CT features of occipital squama normal anatomy, anatomic variations and fractures

    International Nuclear Information System (INIS)

    Liu Jungang; Li Xin; Wang Chunxiang; Zhang Lin; Guo Wanhua

    2013-01-01

    Objective: To evaluate 3D CT features of normal anatomy, anatomic variations and fractures of occipital squama. Methods: The 3D CT features on MIP, VR images were analyzed retrospectively in 589 pediatric cases. The normal anatomy, anatomic variations and fractures of occipital squama were observed respectively, and the differential diagnostic features including the individual location, appearance and extension were analyzed. Results: Four hundred and thirty-three patients (75.2%) showed normal anatomy, including 154 patients with adult occipital anatomical features, 279 patients with posterior intraoccipital synchondrosis, and 37 patients with Kerckring-supraoccipital synchondrosis. When cases with recent trauma history were excluded, 113 patients (19.1%) showed anatomic variants, including unpenetrating sutures and penetrating sutures. The former could be subdivided to Mendosal sutures in 23 cases, superior median fissures in 19 cases, and midline supraoccipital fissures in 4 cases, while the latter could be subdivided to the interparietal bone variations in 54 cases, wormian bones in 23 cases, and accessory bones in 7 cases. Two or more variations coexisted in 33 cases. The occipital squama fractures were shown in 34 cases (5.6%), including linear fractures in 27 cases, comminuted fractures in 3 cases, with depression fracture in one case, separation of cranial sutures in 3 cases, and other fractures associated with variants in 3 cases. The fractures were sharp, or jagged, without limitation of the occification. Conclusion: There are different 3D CT features of normal anatomy, anatomic variations and fractures of occipital squama in children, which are important for making the accurate diagnosis. (authors)

  18. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  19. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  20. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  1. Students perception about the clinico-anatomical conferences as a teaching methodology

    International Nuclear Information System (INIS)

    Saeed, K.; Baptist, M.; Mukhtar, F.

    2015-01-01

    Anatomy has always been considered as an essential basis for clinical sciences. In recent decades there has been an increased trend towards incorporation of clinical problems in the teaching of anatomy. To promote clinical knowledge clinico-anatomical conferences have been conducted in our department for the last five years. This study has been undertaken to determine perception of medical students regarding these conferences and to formulate recommendations for their improvement based on feedback obtained from students. Method: A cross-sectional study was conducted from December 2013 to January 2014 at the Lahore Medical and Dental College (LMDC), Lahore. A sample of 200 students of first and second year MBBS classes was selected for the study through convenience sampling technique. A 5-point Likert scale ranging from 1 (strongly agree) to 5 (strongly disagree) was used to determine students perception about clinic-anatomical conferences, using a self-administered questionnaire. Data was analysed using SPSS-19.0. Results: Out of total 144 (72%) students were of the opinion that clinico-anatomical conferences were a good source of clinical knowledge, 126 (63%) opined that these conferences promoted understanding rather than memorization, 122 (61%) found them interesting, and 15 (30%) found improvement in their grades in the subject of anatomy after attending the conferences. Conclusion: The clinico-anatomical conferences were found interesting and reported to be a good source of clinical knowledge. It is recommended that these conferences should be conducted frequently, made interactive and patients should be presented as case studies during the conferences. (author)

  2. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    Energy Technology Data Exchange (ETDEWEB)

    Maitree, R; Guzman, G; Chundury, A; Roach, M; Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2016-06-15

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and

  3. SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation

    International Nuclear Information System (INIS)

    Maitree, R; Guzman, G; Chundury, A; Roach, M; Yang, D

    2016-01-01

    Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness of available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and

  4. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  5. SU-E-J-176: Characterization of Inter-Fraction Breast Variability and the Implications On Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Sudhoff, M; Lamba, M; Kumar, N; Ward, A; Elson, H [University of Cincinnati, Cincinnati, OH (United States)

    2015-06-15

    Purpose: To systematically characterize inter-fraction breast variability and determine implications on delivered dose. Methods: Weekly port films were used to characterize breast setup variability. Five evenly spaced representative positions across the contour of each breast were chosen on the electronic port film in reference to graticule, and window and level was set such that the skin surface of the breast was visible. Measurements from the skin surface to treatment field edge were taken on each port film at each position and compared to the planning DRR, quantifying the variability. The systematic measurement technique was repeated for all port films for 20 recently treated breast cancer patients. Measured setup variability for each patient was modeled as a normal distribution. The distribution was randomly sampled from the model and applied as isocentric shifts in the treatment planning computer, representing setup variability for each fraction. Dose was calculated for each shifted fraction and summed to obtain DVHs and BEDs that modeled the dose with daily setup variability. Patients were categorized in to relevant groupings that were chosen to investigate the rigorousness of immobilization types, treatment techniques, and inherent anatomical difficulties. Mean position differences and dosimetric differences were evaluated between planned and delivered doses. Results: The setup variability was found to follow a normal distribution with mean position differences between the DRR and port film between − 8.6–3.5 mm with sigma range of 5.3–9.8 mm. Setup position was not found to be significantly different than zero. The mean seroma or whole breast PTV dosimetric difference, calculated as BED, ranged from a −0.23 to +1.13Gy. Conclusion: A systematic technique to quantify and model setup variability was used to calculate the dose in 20 breast cancer patients including variable setup. No statistically significant PTV or OAR BED differences were found between

  6. Anatomically corrected transposition of great vessels

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Sarkisova, T.N.

    1989-01-01

    The paper is concerned with the description of rare congenital heart disease: anatomically corrected malposition of major vessels in a 9-mos 24 day old girl. The diagnosis of this disease was shown on the results of angiocardiography, concomitant congenital heart diseases were descibed. This abnormality is characterized by common atrioventricular and ventriculovascular joints and inversion position of the major vessels, it is always attended by congenital heart diseases. Surgical intervention is aimed at the elimination of concomitant heart dieseases

  7. Aortic anatomic severity grade correlates with resource utilization.

    Science.gov (United States)

    Rasheed, Khurram; Cullen, John P; Seaman, Matthew J; Messing, Susan; Ellis, Jennifer L; Glocker, Roan J; Doyle, Adam J; Stoner, Michael C

    2016-03-01

    Potential cost effectiveness of endovascular aneurysm repair (EVAR) compared with open aortic repair (OAR) is offset by the use of intraoperative adjuncts (components) or late reinterventions. Anatomic severity grade (ASG) can be used preoperatively to assess abdominal aortic aneurysms, and provide a quantitative measure of anatomic complexity. The hypothesis of this study is that ASG is directly related to the use of intraoperative adjuncts and cost of aortic repair. Patients who undergo elective OAR and EVAR for abdominal aortic aneurysms were identified over a consecutive 3-year period. ASG scores were calculated manually using three-dimensional reconstruction software by two blinded reviewers. Statistical analysis of cost data was performed using a log transformation. Regression analyses, with a continuous or dichotomous outcome, used a generalized estimating equations approach with the sandwich estimator, being robust with respect to deviations from model assumptions. One hundred forty patients were identified for analysis, n = 33 OAR and n = 107 EVAR. The mean total cost (± standard deviation) for OAR was per thousand (k) $38.3 ± 49.3, length of stay (LOS) 13.5 ± 14.2 days, ASG score 18.13 ± 3.78; for EVAR, mean total cost was k $24.7 ± 13.0 (P = .016), LOS 3.0 ± 4.4 days (P = .012), ASG score 15.9 ± 4.13 (P = .010). In patients who underwent EVAR, 25.2% required intraoperative adjuncts, and analysis of this group revealed a mean total cost of k $31.5 ± 15.9, ASG score 18.48 ± 3.72, and LOS 3.9 ± 4.5, which were significantly greater compared with cases without adjunctive procedures. An ASG score of ≥15 correlated with an increased propensity for requirement of intraoperative adjuncts; odds ratio, 5.75 (95% confidence interval, 1.82-18.19). ASG >15 was also associated with chronic kidney disease, end stage renal disease, hypertension, female sex, increased cost, and use of adjunctive procedures. Complex aneurysm anatomy correlates with increased

  8. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  9. Maternal Adaptive Immune Cells in Decidua Parietalis Display a More Activated and Coinhibitory Phenotype Compared to Decidua Basalis

    Directory of Open Access Journals (Sweden)

    Martin Solders

    2017-01-01

    Full Text Available The maternal part of the placenta, the decidua, consists of maternal immune cells, decidual stromal cells, and extravillous fetal trophoblasts. In a successful pregnancy, these cell compartments interact to provide an intricate balance between fetal tolerance and antimicrobial defense. These processes are still poorly characterized in the two anatomically different decidual tissues, basalis and parietalis. We examined immune cells from decidua basalis and parietalis from term placentas (n=15 with flow cytometry. By using multivariate discriminant analysis, we found a clear separation between the two decidual compartments based on the 81 investigated parameters. Decidua parietalis lymphocytes displayed a more activated phenotype with a higher expression of coinhibitory markers than those isolated from basalis and contained higher frequencies of T regulatory cells. Decidua basalis contained higher proportions of monocytes, B cells, and mucosal-associated invariant T (MAIT cells. The basalis B cells were more immature, and parietalis MAIT cells showed a more activated phenotype. Conventional T cells, NK cells, and MAIT cells from both compartments potently responded with the production of interferon-γ and/or cytotoxic molecules in response to stimulation. To conclude, leukocytes in decidua basalis and parietalis displayed remarkable phenotypic disparities, indicating that the corresponding stromal microenvironments provide different immunoregulatory signals.

  10. Salt effect on physiological, biochemical and anatomical structures ...

    African Journals Online (AJOL)

    In this study, we evaluated the salt concentration effect on plant growth, mineral composition, antioxidant responses and anatomical structure of two varieties of Origanum majorana after exposure to NaCl treatment. Our results show an inclusive behaviour of the two varieties, since the majority of sodium was exported and ...

  11. Anatomical and procedural determinants of ambulatory blood pressure lowering following catheter-based renal denervation using radiofrequency.

    Science.gov (United States)

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham R; Edelman, Elazer R; Cremers, Bodo; Kulenthiran, Saarraaken; Ukena, Christian; Linz, Dominik; Kindermann, Ingrid; Tsioufis, Costas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-03-02

    Catheter-based renal sympathetic denervation (RDN) has been introduced to lower blood pressure (BP) and sympathetic activity in patients with uncontrolled hypertension with at best equivocal results. It has been postulated that anatomic and procedural elements introduce unaccounted variability and yet little is known of the impact of renal anatomy and procedural parameters on BP response to RDN. Anatomical parameters such as length and diameter were analyzed by quantitative vascular analysis and the prevalence of accessory renal arteries and renal artery disease were documented in 150 patients with resistant hypertension undergoing bilateral RDN using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). Accessory renal arteries and renal artery disease were present in 56 (37%) and 14 patients (9%), respectively. At 6-months, 24 h-ambulatory BP was reduced by 11/6 mm Hg (p renal arteries (p = 0.543) or renal artery disease (p = 0.598). Patients with at least one main renal artery diameter ≤ 4 mm had a more pronounced reduction of 24 h-ambulatory SBP compared to patients where both arteries were >4 mm (-19 vs. -10 mmHg; p = 0.038). Neither the length of the renal artery nor the number of RF ablations influenced 24 h-ambulatory BP reduction at 6 months. 24 h-ambulatory BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, accessory arteries or renal artery disease. Further, there was no dose-response relationship observed with increasing number of ablations. Because little is known of the impact of renal anatomy and procedural parameters on blood pressure (BP) response to renal denervation (RDN), anatomical and procedural data were analyzed in 150 patients undergoing bilateral RDN. BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, the presence of renal artery disease or accessory renal

  12. Bayesian Multiresolution Variable Selection for Ultra-High Dimensional Neuroimaging Data.

    Science.gov (United States)

    Zhao, Yize; Kang, Jian; Long, Qi

    2018-01-01

    Ultra-high dimensional variable selection has become increasingly important in analysis of neuroimaging data. For example, in the Autism Brain Imaging Data Exchange (ABIDE) study, neuroscientists are interested in identifying important biomarkers for early detection of the autism spectrum disorder (ASD) using high resolution brain images that include hundreds of thousands voxels. However, most existing methods are not feasible for solving this problem due to their extensive computational costs. In this work, we propose a novel multiresolution variable selection procedure under a Bayesian probit regression framework. It recursively uses posterior samples for coarser-scale variable selection to guide the posterior inference on finer-scale variable selection, leading to very efficient Markov chain Monte Carlo (MCMC) algorithms. The proposed algorithms are computationally feasible for ultra-high dimensional data. Also, our model incorporates two levels of structural information into variable selection using Ising priors: the spatial dependence between voxels and the functional connectivity between anatomical brain regions. Applied to the resting state functional magnetic resonance imaging (R-fMRI) data in the ABIDE study, our methods identify voxel-level imaging biomarkers highly predictive of the ASD, which are biologically meaningful and interpretable. Extensive simulations also show that our methods achieve better performance in variable selection compared to existing methods.

  13. MRI anatomical mapping and direct stereotactic targeting in the subthalamic region: functional and anatomical correspondence in Parkinson's disease

    International Nuclear Information System (INIS)

    Lemaire, Jean-Jacques; Coste, Jerome; Ouchchane, Lemlih; Hemm, Simone; Derost, Philippe; Ulla, Miguel; Durif, Franck; Siadoux, Severine; Gabrillargues, Jean; Chazal, Jean

    2007-01-01

    Object Relationships between clinical effects, anatomy, and electrophysiology are not fully understood in DBS of the subthalamic region in Parkinson's disease. We proposed an anatomic study based on direct image-guided stereotactic surgery with a multiple source data analysis. Materials and Methods A manual anatomic mapping was realized on coronal 1.5-Tesla MRI of 15 patients. Biological data were collected under local anesthesia: the spontaneous neuron activities and the clinical efficiency and the appearance of adverse effects. They were related to relevant current values (mA), the benefit threshold (bt, minimal current leading an clear efficiency), the adverse effect threshold (at, minimal current leading an adverse effect) and the stimulation margin (sm = at - bt); they were matched with anatomy. Results We found consistent relationships between anatomy and biological data. The optimal stimulation parameters (low bt + high sm) were noted in the dorsolateral STN. The highest spontaneous neuron activity was found in the ventromedial STN. Dorsolateral (sensorimotor) STN seems the main DBS effector. The highest spontaneous neuron activity seems related to the anterior (rostral) ventromedial (limbic) STN. Conclusion 1.5 Tesla images provide sufficiently detailed subthalamic anatomy for image-guided stereotactic surgery and may aid in understanding DBS mechanisms. (orig.)

  14. IDEA: Interactive Display for Evolutionary Analyses.

    Science.gov (United States)

    Egan, Amy; Mahurkar, Anup; Crabtree, Jonathan; Badger, Jonathan H; Carlton, Jane M; Silva, Joana C

    2008-12-08

    The availability of complete genomic sequences for hundreds of organisms promises to make obtaining genome-wide estimates of substitution rates, selective constraints and other molecular evolution variables of interest an increasingly important approach to addressing broad evolutionary questions. Two of the programs most widely used for this purpose are codeml and baseml, parts of the PAML (Phylogenetic Analysis by Maximum Likelihood) suite. A significant drawback of these programs is their lack of a graphical user interface, which can limit their user base and considerably reduce their efficiency. We have developed IDEA (Interactive Display for Evolutionary Analyses), an intuitive graphical input and output interface which interacts with PHYLIP for phylogeny reconstruction and with codeml and baseml for molecular evolution analyses. IDEA's graphical input and visualization interfaces eliminate the need to edit and parse text input and output files, reducing the likelihood of errors and improving processing time. Further, its interactive output display gives the user immediate access to results. Finally, IDEA can process data in parallel on a local machine or computing grid, allowing genome-wide analyses to be completed quickly. IDEA provides a graphical user interface that allows the user to follow a codeml or baseml analysis from parameter input through to the exploration of results. Novel options streamline the analysis process, and post-analysis visualization of phylogenies, evolutionary rates and selective constraint along protein sequences simplifies the interpretation of results. The integration of these functions into a single tool eliminates the need for lengthy data handling and parsing, significantly expediting access to global patterns in the data.

  15. Influence of the different anteromedial portal on femoral tunnel orientation during anatomic ACL reconstruction

    Directory of Open Access Journals (Sweden)

    Dong-Kyu Moon

    2017-05-01

    Conclusions: In anatomic ACL reconstruction, a mal-positioned AM portal can cause abnormal tunnel orientation, which may lead to mechanical failure during ACL reconstruction. Therefore, it is important to select accurate AM portal positioning, and possibly using an AAM portal by measuring an accurate position when drilling a femoral tunnel in anatomic ACL reconstruction.

  16. Three-Dimensional Anatomic Evaluation of the Anterior Cruciate Ligament for Planning Reconstruction

    Directory of Open Access Journals (Sweden)

    Yuichi Hoshino

    2012-01-01

    Full Text Available Anatomic study related to the anterior cruciate ligament (ACL reconstruction surgery has been developed in accordance with the progress of imaging technology. Advances in imaging techniques, especially the move from two-dimensional (2D to three-dimensional (3D image analysis, substantially contribute to anatomic understanding and its application to advanced ACL reconstruction surgery. This paper introduces previous research about image analysis of the ACL anatomy and its application to ACL reconstruction surgery. Crucial bony landmarks for the accurate placement of the ACL graft can be identified by 3D imaging technique. Additionally, 3D-CT analysis of the ACL insertion site anatomy provides better and more consistent evaluation than conventional “clock-face” reference and roentgenologic quadrant method. Since the human anatomy has a complex three-dimensional structure, further anatomic research using three-dimensional imaging analysis and its clinical application by navigation system or other technologies is warranted for the improvement of the ACL reconstruction.

  17. Radio-guided sentinel lymph node identification by lymphoscintigraphy fused with an anatomical vector profile: clinical applications.

    Science.gov (United States)

    Niccoli Asabella, A; Antonica, F; Renna, M A; Rubini, D; Notaristefano, A; Nicoletti, A; Rubini, G

    2013-12-01

    To develop a method to fuse lymphoscintigraphic images with an adaptable anatomical vector profile and to evaluate its role in the clinical practice. We used Adobe Illustrator CS6 to create different vector profiles, we fused those profiles, using Adobe Photoshop CS6, with lymphoscintigraphic images of the patient. We processed 197 lymphoscintigraphies performed in patients with cutaneous melanomas, breast cancer or delayed lymph drainage. Our models can be adapted to every patient attitude or position and contain different levels of anatomical details ranging from external body profiles to the internal anatomical structures like bones, muscles, vessels, and lymph nodes. If needed, more new anatomical details can be added and embedded in the profile without redrawing them, saving a lot of time. Details can also be easily hidden, allowing the physician to view only relevant information and structures. Fusion times are about 85 s. The diagnostic confidence of the observers increased significantly. The validation process showed a slight shift (mean 4.9 mm). We have created a new, practical, inexpensive digital technique based on commercial software for fusing lymphoscintigraphic images with built-in anatomical reference profiles. It is easily reproducible and does not alter the original scintigraphic image. Our method allows a more meaningful interpretation of lymphoscintigraphies, an easier recognition of the anatomical site and better lymph node dissection planning.

  18. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  19. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  20. Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics.

    Science.gov (United States)

    Della Croce, Ugo; Leardini, Alberto; Chiari, Lorenzo; Cappozzo, Aurelio

    2005-02-01

    Estimating the effects of different sources of error on joint kinematics is crucial for assessing the reliability of human movement analysis. The goal of the present paper is to review the different approaches dealing with joint kinematics sensitivity to rotation axes and the precision of anatomical landmark determination. Consistent with the previous papers in this series, the review is limited to studies performed with video-based stereophotogrammetric systems. Initially, studies dealing with estimates of precision in determining the location of both palpable and internal anatomical landmarks are reviewed. Next, the effects of anatomical landmark position uncertainty on anatomical frames are shown. Then, methods reported in the literature for estimating error propagation from anatomical axes location to joint kinematics are described. Interestingly, studies carried out using different approaches reported a common conclusion: when joint rotations occur mainly in a single plane, minor rotations out of this plane are strongly affected by errors introduced at the anatomical landmark identification level and are prone to misinterpretation. Finally, attempts at reducing joint kinematics errors due to anatomical landmark position uncertainty are reported. Given the relevance of this source of errors in the determination of joint kinematics, it is the authors' opinion that further efforts should be made in improving the reliability of the joint axes determination.

  1. The macro-structural variability of the human neocortex.

    Science.gov (United States)

    Kruggel, Frithjof

    2018-05-15

    The human neocortex shows a considerable individual structural variability. While primary gyri and sulci are found in all normally developed brains and bear clear-cut gross structural descriptions, secondary structures are highly variable and not present in all brains. The blend of common and individual structures poses challenges when comparing structural and functional results from quantitative neuroimaging studies across individuals, and sets limits on the precision of location information much above the spatial resolution of current neuroimaging methods. This work aimed at quantifying structural variability on the neocortex, and at assessing the spatial relationship between regions common to all brains and their individual structural variants. Based on structural MRI data provided as the "900 Subjects Release" of the Human Connectome Project, a data-driven analytic approach was employed here from which the definition of seven cortical "communities" emerged. Apparently, these communities comprise common regions of structural features, while the individual variability is confined within a community. Similarities between the community structure and the state of the brain development at gestation week 32 lead suggest that communities are segregated early. Subdividing the neocortex into communities is suggested as anatomically more meaningful than the traditional lobar structure. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Brachial plexus lesions: Anatomical knowledge as an essential ...

    African Journals Online (AJOL)

    This clinical feature was in conformity with a lesion of inferior primary trunk. All diagnoses were made based on the clinical findings. These cases demonstrate the significance of a through anatomical knowledge in the clinical examination if one has to avoid confusing the signs of terminal nerves lesion with the trunk's lesion.

  3. Design of Programmable LED Controller with a Variable Current Source for 3D Image Display

    Directory of Open Access Journals (Sweden)

    Kyung-Ryang Lee

    2014-12-01

    Full Text Available Conventional fluorescent light sources, as well as incandescent light sources are gradually being replaced by Light Emitting Diodes (LEDs for reducing power consumption in the image display area for multimedia application. An LED light source requires a controller with a low-power operation. In this paper, a low-power technique using adiabatic operation is applied for the implementation of LED controller with a stable constant-current, a low-power and low-heat function. From the simulation result, the power consumption of the proposed LED controller using adiabatic operation was reduced to about 87% in comparison with conventional operation with a constant VDD. The proposed circuit is expected to be an alternative LED controller which is sensitive to external conditions such as heat.

  4. Anatomical and magnetic resonance imaging study of the medial ...

    African Journals Online (AJOL)

    Sally Mahmood Mohamed Hussin Omar

    2015-07-10

    Jul 10, 2015 ... The tendon sheath of the posterior tibial muscle covers the posterior and ..... may be associated with avulsion fractures at either the origin or the insertion .... 14. Shibata Y, Nishi G, Masegi A. Stress test and anatomical study of.

  5. Extra-anatomic transplantations in autologous adult cell therapies aiding anatomical regeneration and physiological recovery – An insight and categorization

    Directory of Open Access Journals (Sweden)

    Editorial

    2015-12-01

    Full Text Available Autologous mature adult cells as well as stem cells, which are not considered pluripotent, have been reported to be safe and efficacious in clinical applications for regenerating cartilage [1] and corneal epithelium [2]. Use of primary autologous cells and stem cells expanded in number from cartilage and corneal epithelial tissues have shown abilities to reconstruct and regenerate tissues, de novo. It is to be noted that in both these cases, the source of the cells that have been used for transplantation into the cornea and cartilage have been from the same organ and tissue. The replacement cells for regeneration have also been sourced from the same germ layer, as that of the cells of the target tissue; corneal epithelial tissue embryologically originating from the ectoderm has been replaced with corneal limbal stem cells that are also of ectodermal origin from the unaffected healthy eye of the same individual. Similarly, the cartilage which developmentally is from the mesoderm has been replaced with mature chondrocytes from the non-weight bearing area of the cartilage, again of the same individual. Figure 1: Autologous, in vitro cultured, adult cell based therapies; An overview and categorization. (Click here for High Resol. Image The proceedings of the IIDIAS session published in this issue have described two novel cell therapies, where cells taken from a tissue or organ, after normal in vitro expansion, have been clinically applied to aid the regeneration of a different tissue or organ, i.e skeletal myoblasts having been used for myocardial regeneration and buccal mucosal epithelium having been used for corneal epithelial regeneration heralding the birth of a new paradigm called ‘extra-anatomic cell therapy’. The myocardium is a specialized muscle in that it works as an electrical synctitium with an intrinsic capacity to generate and propagate action potentials (involuntary as opposed to the skeletal muscles that are dependent on neuronal

  6. SNS online display technologies for EPICS

    International Nuclear Information System (INIS)

    Kasemir, K.U.; Chen, X.; Purcell, J.; Danilova, E.

    2012-01-01

    The ubiquitousness of web clients from personal computers to cell phones results in a growing demand for web-based access to control system data. At the Oak Ridge National Laboratory Spallation Neutron Source (SNS) we have investigated different technical approaches to provide read access to data in the Experimental Physics and Industrial Control System (EPICS) for a wide variety of web client devices. The core web technology, HTTP, is less than ideal for online control system displays. Appropriate use of Ajax, especially the Long Poll paradigm, can alleviate fundamental HTTP limitations. The SNS Status web uses basic Ajax technology to generate generic displays for a wide audience. The Dashboard uses Long Poll and more client-side Java-Script to offer more customization and faster updates for users that need specialized displays. The Web OPI uses RAP for web access to any BOY display, offering utmost flexibility because users can create their own BOY displays in CSS. These three approaches complement each other. Users can access generic status displays with zero effort, invest time in creating their fully customized displays for the Web OPI, or use the Dashboard as an intermediate solution

  7. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  8. Interfractional Variations in Patient Setup and Anatomic Change Assessed by Daily Computed Tomography

    International Nuclear Information System (INIS)

    Li, X. Allen; Qi, X. Sharon; Pitterle, Marissa; Kalakota, Kapila; Mueller, Kevin; Erickson, Beth A.; Wang Dian; Schultz, Christopher J.; Firat, Selim Y.; Wilson, J. Frank

    2007-01-01

    Purpose: To analyze the interfractional variations in patient setup and anatomic changes at seven anatomic sites observed in image-guided radiotherapy. Methods and Materials: A total of 152 patients treated at seven anatomic sites using a Hi-Art helical tomotherapy system were analyzed. Daily tomotherapy megavoltage computed tomography images acquired before each treatment were fused to the planning kilovoltage computed tomography images to determine the daily setup errors and organ motions and deformations. The setup errors were corrected before treatment and were used, along with the organ motions, to determine the clinical target volume/planning target volume margins. The organ motions and deformations for 3 representative patient cases (pancreas, uterus, and soft-tissue sarcoma) and for 14 kidneys of 7 patients are presented. Results: Interfractional setup errors in the skull, brain, and head and neck are significantly smaller than those in the chest, abdomen, pelvis, and extremities. These site-specific relationships are statistically significant. The margins required to account for these setup errors range from 3 to 8 mm for the seven sites. The margin to account for both setup errors and organ motions for kidney is 16 mm. Substantial interfractional anatomic changes were observed. For example, the pancreas moved up to ±20 mm and volumes of the uterus and sarcoma varied ≤30% and 100%, respectively. Conclusion: The interfractional variations in patient setup and in shapes, sizes, and positions of both targets and normal structures are site specific and may be used to determine the site-specific margins. The data presented in this work dealing with seven anatomic sites may be useful in developing adaptive radiotherapy

  9. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  10. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  11. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  12. Leaf responses to drought stress in Mediterranean accessions of Solanum lycopersicum: anatomical adaptations in relation to gas exchange parameters.

    Science.gov (United States)

    Galmés, Jeroni; Ochogavía, Joan Manuel; Gago, Jorge; Roldán, Emilio José; Cifre, Josep; Conesa, Miquel Àngel

    2013-05-01

    In a previous study, important acclimation to water stress was observed in the Ramellet tomato cultivar (TR) from the Balearic Islands, related to an increase in the water-use efficiency through modifications in both stomatal (g(s)) and mesophyll conductances (g(m)). In the present work, the comparison of physiological and morphological traits between TR accessions grown with and without water stress confirmed that variability in the photosynthetic capacity was mostly explained by differences in the diffusion of CO2 through stomata and leaf mesophyll. Maximization of gm under both treatments was mainly achieved through adjustments in the mesophyll thickness and porosity and the surface area of chloroplasts exposed to intercellular airspace (S(c)). In addition, the lower g(m) /S(c) ratio for a given porosity in drought-acclimated plants suggests that the decrease in gm was due to an increased cell wall thickness. Stomatal conductance was also affected by drought-associated changes in the morphological properties of stomata, in an accession and treatment-dependent manner. The results confirm the presence of advantageous physiological traits in the response to drought stress in Mediterranean accessions of tomato, and relate them to particular changes in the leaf anatomical properties, suggesting specific adaptive processes operating at the leaf anatomical level. © 2012 Blackwell Publishing Ltd.

  13. Anatomical factors predicting lower calyceal stone clearance after ...

    African Journals Online (AJOL)

    M. Khan

    2016-02-17

    Feb 17, 2016 ... Curr Opin Urol 2008;18:214–9. [9] Lingeman JE, Siegal YI, Steele B, Nyhus AW, Woods JR. Manage- ment of lower pole nephrolithiasis: a critical analysis. J Urol 1994;151: 663–7. [10] Sampaio FJB, Aragao AHM. Limitations of extracorporeal shock wave lithotripsy for lower caliceal stone: anatomic insight.

  14. The new vestibular stimuli: sound and vibration-anatomical, physiological and clinical evidence.

    Science.gov (United States)

    Curthoys, Ian S

    2017-04-01

    The classical view of the otoliths-as flat plates of fairly uniform receptors activated by linear acceleration dragging on otoconia and so deflecting the receptor hair bundles-has been replaced by new anatomical and physiological evidence which shows that the maculae are much more complex. There is anatomical spatial differentiation across the macula in terms of receptor types, hair bundle heights, stiffness and attachment to the overlying otolithic membrane. This anatomical spatial differentiation corresponds to the neural spatial differentiation of response dynamics from the receptors and afferents from different regions of the otolithic maculae. Specifically, receptors in a specialized band of cells, the striola, are predominantly type I receptors, with short, stiff hair bundles and looser attachment to the overlying otoconial membrane than extrastriolar receptors. At the striola the hair bundles project into holes in the otolithic membrane, allowing for fluid displacement to deflect the hair bundles and activate the cell. This review shows the anatomical and physiological evidence supporting the hypothesis that fluid displacement, generated by sound or vibration, deflects the short stiff hair bundles of type I receptors at the striola, resulting in neural activation of the irregular afferents innervating them. So these afferents are activated by sound or vibration and show phase-locking to individual cycles of the sound or vibration stimulus up to frequencies above 2000 Hz, underpinning the use of sound and vibration for clinical tests of vestibular function.

  15. Simultaneous anatomical sketching as learning by doing method of teaching human anatomy.

    Science.gov (United States)

    Noorafshan, Ali; Hoseini, Leila; Amini, Mitra; Dehghani, Mohammad-Reza; Kojuri, Javad; Bazrafkan, Leila

    2014-01-01

    Learning by lecture is a passive experience. Many innovative techniques have been presented to stimulate students to assume a more active attitude toward learning. In this study, simultaneous sketch drawing, as an interactive learning technique was applied to teach anatomy to the medical students. We reconstructed a fun interactive model of teaching anatomy as simultaneous anatomic sketching. To test the model's instruction effectiveness, we conducted a quasi- experimental study and then the students were asked to write their learning experiences in their portfolio, also their view was evaluated by a questionnaire. The results of portfolio evaluation revealed that students believed that this method leads to deep learning and understanding anatomical subjects better. Evaluation of the students' views on this teaching approach was showed that, more than 80% of the students were agreed or completely agreed with this statement that leaning anatomy concepts are easier and the class is less boring with this method. More than 60% of the students were agreed or completely agreed to sketch anatomical figures with professor simultaneously. They also found the sketching make anatomy more attractive and it reduced the time for learning anatomy. These number of students were agree or completely agree that the method help them learning anatomical concept in anatomy laboratory. More than 80% of the students found the simultaneous sketching is a good method for learning anatomy overall. Sketch drawing, as an interactive learning technique, is an attractive for students to learn anatomy.

  16. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  17. Dimensions of Situatedness for Digital Public Displays

    Directory of Open Access Journals (Sweden)

    Rui José

    2014-01-01

    Full Text Available Public displays are often strongly situated signs deeply embedded in their physical, social, and cultural setting. Understanding how the display is coupled with on-going situations, its level of situatedness, provides a key element for the interpretation of the displays themselves but is also an element for the interpretation of place, its situated practices, and its social context. Most digital displays, however, do not achieve the same sense of situatedness that seems so natural in their nondigital counterparts. This paper investigates people’s perception of situatedness when considering the connection between public displays and their context. We have collected over 300 photos of displays and conducted a set of analysis tasks involving focus groups and structured interviews with 15 participants. The contribution is a consolidated list of situatedness dimensions that should provide a valuable resource for reasoning about situatedness in digital displays and informing the design and development of display systems.

  18. Anatomical Peculiarities in Wheat (Triticum Aestivum L.) varieties Under Copper Stress

    International Nuclear Information System (INIS)

    Atabayeva, S.; Nurmahanova, A.; Akhmetova, A.; Narmuratova, M.; Asrandina, S.; Alybayeva, R.

    2016-01-01

    The effect of different concentrations (0.25 mM, 0.5 mM) of Cu/sup 2+/ on anatomical parameters of leaves and roots was investigated in hydroponically grown five wheat (Triticum aestivum L.) varieties (Kazakhstanskaya rannaya, Kazakhstanskaya-3, Melturn, Kaiyr and Shagala). The results showed that wheat varieties exposed to 0.5 mM Cu/sup 2+/ exhibited significant alterations in anatomical structure of leaves and roots. The thickness of the upper and lower epidermis, diameter of vascular bundles of leaves of almost all varieties showed a tendency to decrease under copper stress. Our experiments showed an activation of defense responses in the root anatomical structure like exodermis thickening in some varieties in the presence of copper in growth medium as compared to the control. This indicates that copper ions increase the thickness of exodermis, which reduce the absorption of toxic elements by root cells. Copper stress caused a decrease in the thickness of the lower and upper epidermis to varying degrees and reduction in the diameter of vascular bundles of wheat leaves. Copper stress caused a reduction in endodermis thickness thereby decreasing the diameter of the central cylinder of wheat roots. (author)

  19. Anatomical localization of commensal bacteria in immune cell homeostasis and disease.

    Science.gov (United States)

    Fung, Thomas C; Artis, David; Sonnenberg, Gregory F

    2014-07-01

    The mammalian gastrointestinal (GI) tract is colonized by trillions of beneficial commensal bacteria that are essential for promoting normal intestinal physiology. While the majority of commensal bacteria are found in the intestinal lumen, many species have also adapted to colonize different anatomical locations in the intestine, including the surface of intestinal epithelial cells (IECs) and the interior of gut-associated lymphoid tissues. These distinct tissue localization patterns permit unique interactions with the mammalian immune system and collectively influence intestinal immune cell homeostasis. Conversely, dysregulated localization of commensal bacteria can lead to inappropriate activation of the immune system and is associated with numerous chronic infectious, inflammatory, and metabolic diseases. Therefore, regulatory mechanisms that control proper anatomical containment of commensal bacteria are essential to maintain tissue homeostasis and limit pathology. In this review, we propose that commensal bacteria associated with the mammalian GI tract can be anatomically defined as (i) luminal, (ii) epithelial-associated, or (iii) lymphoid tissue-resident, and we discuss the role and regulation of these microbial populations in health and disease. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Fabrication and perfusion culture of anatomically shaped artificial bone using stereolithography

    International Nuclear Information System (INIS)

    Du, Dajiang; Asaoka, Teruo; Ushida, Takashi; Furukawa, Katsuko S

    2014-01-01

    Because patient bone defects are usually varied and complicated in geometry, it would be preferred to fabricate custom-made artificial bone grafts that are anatomically specific to individual patient defects. Using a rabbit femoral segment as a bone reconstruction model, we successfully produced customized ceramic scaffolds by stereolithography, which not only had an anatomically correct external shape according to computed tomography data but also contained an interconnecting internal network of channels designed for perfusion culture. Rabbit bone marrow stromal cells were isolated and cultured with these scaffolds using a novel oscillatory perfusion system that was stereolithographically fabricated to fit well to the unique scaffold shapes. After five days of three-dimensional culture with oscillatory perfusion, the cells attached and proliferated homogenously in the scaffolds. However, control cells inside the scaffolds cultured under static conditions were dead after prolonged in vitro culture. Cellular DNA content and alkaline phosphatase activities were significantly higher in the perfusion group versus the static group. Therefore, anatomically correct artificial bone can be successfully constructed using stereolithography and oscillatory culture technology, and could be useful for bone engraftment and defect repair. (paper)

  1. Gross anatomical syringeal structures of goose (Anser anser domesticus

    Directory of Open Access Journals (Sweden)

    Reda Mohamed

    2017-12-01

    Conclusion: There were some similarities and some differences of the anatomical structures of the syrinx of goose and that of other bird species. No differences between male and female syrinx were observed. [J Adv Vet Anim Res 2017; 4(4.000: 343-347

  2. Anatomical likelihood estimation meta-analysis of grey and white matter anomalies in autism spectrum disorders

    Directory of Open Access Journals (Sweden)

    Thomas P. DeRamus

    2015-01-01

    Full Text Available Autism spectrum disorders (ASD are characterized by impairments in social communication and restrictive, repetitive behaviors. While behavioral symptoms are well-documented, investigations into the neurobiological underpinnings of ASD have not resulted in firm biomarkers. Variability in findings across structural neuroimaging studies has contributed to difficulty in reliably characterizing the brain morphology of individuals with ASD. These inconsistencies may also arise from the heterogeneity of ASD, and wider age-range of participants included in MRI studies and in previous meta-analyses. To address this, the current study used coordinate-based anatomical likelihood estimation (ALE analysis of 21 voxel-based morphometry (VBM studies examining high-functioning individuals with ASD, resulting in a meta-analysis of 1055 participants (506 ASD, and 549 typically developing individuals. Results consisted of grey, white, and global differences in cortical matter between the groups. Modeled anatomical maps consisting of concentration, thickness, and volume metrics of grey and white matter revealed clusters suggesting age-related decreases in grey and white matter in parietal and inferior temporal regions of the brain in ASD, and age-related increases in grey matter in frontal and anterior-temporal regions. White matter alterations included fiber tracts thought to play key roles in information processing and sensory integration. Many current theories of pathobiology ASD suggest that the brains of individuals with ASD may have less-functional long-range (anterior-to-posterior connections. Our findings of decreased cortical matter in parietal–temporal and occipital regions, and thickening in frontal cortices in older adults with ASD may entail altered cortical anatomy, and neurodevelopmental adaptations.

  3. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  4. [Application of polyguanidine solution for fixation of biological and anatomical specimens].

    Science.gov (United States)

    Anichkov, N M; Danilova, I A; Riabinin, I A; Kipenko, A V

    2010-01-01

    A new method for fixation of biological material is described, and its effectiveness is compared to that one of formalin fixation. As an embalming agent, polyhexamethylenguanidine (PHMG) hydrochloride was used. Using the proposed method of fixation, the anatomical and histological preparations of human organs and of chick embryos at developmental 12 days, were produced. The anatomical preparations obtained show the appearance, similar to that of the recently removed organs. Histological preparations were free from significant distortions of the microscopic characteristics of the specimens, which are typical to the material fixed with formalin. The results of the study suggest the possibility of PHMG application in the morphological studies.

  5. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  6. Effects of age, gender, BMI, and anatomical site on skin thickness in children and adults with diabetes.

    Directory of Open Access Journals (Sweden)

    José G B Derraik

    Full Text Available We aimed to assess the effects of age, sex, body mass index (BMI, and anatomical site on skin thickness in children and adults with diabetes.We studied 103 otherwise healthy children and adolescents with type 1 diabetes aged 5-19 years, and 140 adults with type 1 and type 2 diabetes aged 20-85 years. The thicknesses of both the dermis and subcutis were assessed using ultrasound with a linear array transducer, on abdominal and thigh skin.There was an age-related thickening of both dermis (p<0.0001 and subcutis (p = 0.013 in children and adolescents. Girls displayed a substantial pubertal increase in subcutis of the thigh (+54%; p = 0.048 and abdomen (+68%; p = 0.009. Adults showed an age-related decrease in dermal (p = 0.021 and subcutis (p = 0.009 thicknesses. Pubertal girls had a thicker subcutis than pubertal boys in both thigh (16.7 vs 7.5 mm; p<0.0001 and abdomen (16.7 vs 8.8 mm; p<0.0001. Men had greater thigh dermal thickness than women (1.89 vs 1.65 mm; p = 0.003, while the subcutis was thicker in women in thigh (21.3 vs 17.9 mm; p = 0.012 and abdomen (17.7 vs 9.8 mm; p<0.0001. In boys, men, and women, both dermis and subcutis were thicker on the abdomen compared to thigh; in girls this was only so for dermal thickness. In both children and adults, the skin (dermis and subcutis became steadily thicker with increasing BMI (p<0.0001.Skin thickness is affected by age, pubertal status, gender, BMI, and anatomical site. Such differences may be important when considering appropriate sites for dermal/subcutaneous injections and other transdermal delivery systems.

  7. Microencapsulated Electrophoretic Films for Electronic Paper Displays

    Science.gov (United States)

    Amundson, Karl

    2003-03-01

    Despite the dominance of liquid crystal displays, they do not perform some functions very well. While backlit liquid crystal displays can offer excellent color performance, they wash out in bright lighting and suffer from high power consumption. Reflective liquid crystal displays have limited brightness, making these devices challenging to read for long periods of time. Flexible liquid crystal displays are difficult to manufacture and keep stable. All of these attributes (long battery lifetime, bright reflective appearance, compatibility with flexible substrates) are traits that would be found in an ideal electronic paper display - an updateable substitute for paper that could be employed in electronic books, newspapers, and other applications. I will discuss technologies that are being developed for electronic-paper-like displays, and especially on particle-based technologies. A microencapsulated electrophoretic display technology is being developed at the E Ink corporation. This display film offers offer high brightness and an ink-on-paper appearance, compatibility with flexible substrates, and image stability that can lead to very low power consumption. I will present some of the physical and chemical challenges associated with making display films with high performance.

  8. Lingual Foramina and Canals of the Mandible: Anatomic Variations in a Lebanese Population

    Directory of Open Access Journals (Sweden)

    Georges Aoun

    2017-01-01

    Full Text Available Objective: The aim of this study was to evaluate the mandibular lingual foramina (LF and canals and their anatomic variations using cone-beam computed tomography (CBCT technology in a Lebanese population. Materials and Methods: In this study, we analyzed CBCT images of 90 adult Lebanese patients (41 males and 49 females. We assessed the number and location of the LF. In additional, we measured: (a The distance from both the alveolar crest and the inferior border of the mandible to the LF and (b the length of the lingual canals (LCs. The data obtained was analyzed statistically using Shapiro–Wilk normality test, t-test, Chi-square, and Fisher's exact tests. Statistical significance was set at 0.05. Results: In our sample, the LF and canals were present in 93.33% of the CBCT analyzed, and the majority (76.64% was located above the genial tubercles. The distance from the foramen of the superior and the inferior LCs to the alveolar crest was 16.24 ± 2.82 mm and 25.49 ± 2.43 mm, respectively. The distance from the foramen of the superior canal to the inferior border of the mandible was 14 ± 2.32 mm. The mean length of the superior canal was 5.81 ± 1.6 mm and 4.25 ± 1.2 mm for the inferior one. There were no gender-related differences in the anatomic characteristics of the LF and canals except for the distance measured from the superior canal foramina to the alveolar crest where the measurement was significantly greater in males compared to females. Neither the number of canals nor the positions of the foramina were different between males and females. Conclusion: Within the limits of this study, we concluded that in our sample of Lebanese adults, there was substantial variability in the LF and canals anatomy and location.

  9. Volumetric Nephrogram Represents Renal Function and Complements Aortic Anatomic Severity Grade in Predicting EVAR Outcomes.

    Science.gov (United States)

    Balceniuk, Mark D; Trakimas, Lauren; Aghaie, Claudia; Mix, Doran; Rasheed, Khurram; Seaman, Matthew; Ellis, Jennifer; Glocker, Roan; Doyle, Adam; Stoner, Michael C

    2018-07-01

    Chronic kidney disease (CKD) is a predictor of poor outcomes for patients undergoing endovascular aortic aneurysm repair (EVAR). Anatomic severity grade (ASG) represents a quantitative mechanism for assessing anatomical suitability for endovascular aortic repair. Anatomic severity grade has been correlated with repair outcomes and resource utilization. The purpose of this study was to identify a novel renal perfusion metric as a way to assist ASG with predicting EVAR outcomes. Retrospective review of a prospectively maintained database identified elective infrarenal aortic aneurysm repair cases. Anatomic grading was undertaken by independent reviewers. Using volumetric software, kidney volume, and a novel measure of kidney functional volume, the volumetric nephrogram (VN) was recorded. Systematic evaluation of the relationship of kidney volume and VN to CKD and ASG was undertaken using linear regression and receiver-operator statistical tools. A total of 386 cases with patient and anatomic data were identified and graded. Mean age was 72.9 ± 0.4 years. Renal volume renal volume (AUC = .628; P ≤ .0001) and VN (AUC = .628; P ≤ .0001). Regression analysis demonstrated a strong, inverse relationship between ASG and VN ( R 2 = .95). These data demonstrate that VN is a strong predictor of CKD in a large database of patients undergoing elective aneurysm repair. We demonstrate an inverse relationship between renal function and ASG that has not been previously described in the literature. Additionally, we have shown that VN complements ASG as a model of overall cardiovascular health and atherosclerotic burden. Outcomes in patients with poor renal function may be related to anatomical issues in addition to well-described systemic ramifications.

  10. A general XML schema and SPM toolbox for storage of neuro-imaging results and anatomical labels.

    Science.gov (United States)

    Keator, David Bryant; Gadde, Syam; Grethe, Jeffrey S; Taylor, Derek V; Potkin, Steven G

    2006-01-01

    With the increased frequency of multisite, large-scale collaborative neuro-imaging studies, the need for a general, self-documenting framework for the storage and retrieval of activation maps and anatomical labels becomes evident. To address this need, we have developed and extensible markup language (XML) schema and associated tools for the storage of neuro-imaging activation maps and anatomical labels. This schema, as part of the XML-based Clinical Experiment Data Exchange (XCEDE) schema, provides storage capabilities for analysis annotations, activation threshold parameters, and cluster and voxel-level statistics. Activation parameters contain information describing the threshold, degrees of freedom, FWHM smoothness, search volumes, voxel sizes, expected voxels per cluster, and expected number of clusters in the statistical map. Cluster and voxel statistics can be stored along with the coordinates, threshold, and anatomical label information. Multiple threshold types can be documented for a given cluster or voxel along with the uncorrected and corrected probability values. Multiple atlases can be used to generate anatomical labels and stored for each significant voxel or cluter. Additionally, a toolbox for Statistical Parametric Mapping software (http://www. fil. ion.ucl.ac.uk/spm/) was created to capture the results from activation maps using the XML schema that supports both SPM99 and SPM2 versions (http://nbirn.net/Resources/Users/ Applications/xcede/SPM_XMLTools.htm). Support for anatomical labeling is available via the Talairach Daemon (http://ric.uthscsa. edu/projects/talairachdaemon.html) and Automated Anatomical Labeling (http://www. cyceron.fr/freeware/).

  11. Unilateral Duplication Of Parotid Duct. A Rare Anatomical Variation

    Directory of Open Access Journals (Sweden)

    Humberto Ferreira Arquez

    2017-11-01

    Full Text Available Background: The paired parotid glands are the largest of the major salivary glands and produces mainly serous secretions. The secretion of this gland reaches the oral cavity through single parotid duct (Stensen’s duct. The parotid duct begins at the anterior border of the gland, crosses the masseter muscle, and then pierces the buccinator muscle to reach the mucosa lining the mouth at the level of the cheek. The purpose of this study is determine the morphologic features of the parotid duct and describe an anatomical variation until now unreported. Methods and Findings: A total of 17 cadavers were used for this study in the Morphology Laboratory at the University of Pamplona. In a cadaver were findings: The main parotid duct originated two conducts: Left superior parotid duct and Left inferior parotid duct, is observed the criss-cross of the ducts, and then perforated the buccinator muscle and entered the oral cavity at a double parotid papilla containing a double opening, separated from each other in 0,98 mm. In the remaining  33 parotid regions (97.06% the parotid duct is conformed to the classical descriptions given in anatomical textbooks. Conclusions: The parotid duct anatomy is important for duct endoscopy, lithotripsy, sialography and trans-ductal facial nerve stimulation in the early stage of facial palsy in some cases. The anatomical variations also has clinical importance for parotid gland surgery and facial cosmetic surgery. To keep in mind the parotid duct variation will reduce iatrogenic injury risks and improve diagnosis of parotid duct injury.

  12. Morpho-anatomical and physicochemical studies of Fumaria indica (Hausskn.) Pugsley

    Institute of Scientific and Technical Information of China (English)

    Prakash Chandra Gupta; Ch V Rao

    2012-01-01

    To study morpho-anatomical characters and physicochemical analysis ofFumaria indica (F. indica) (Hausskn.) Pugsley, (Fumariaceae), an important medicinal plant used extensively for treating a variety of ailments in various system of indigenous medicine.Methods:Evaluation of the different parts of the plant was carried out to determine the morpho-anatomical, physicochemical, phytochemical and HPTLC fingerprinting profile of F. indica and other WHO recommended methods were performed for standardization. Results: Morpho-anatomical studies showed compound and pinnatifid leaf, 4 to 6 cm in length, linear and oblong in shape and anomocytic arrangement of stomata, thin walled parenchymatous cells, scattered, sclerenchymatous, capped vascular bundles and radiating medullary rays. Physicochemical studies showed foreign matter 0.2%, loss on drying 6.8%, total ash 16.77%, alcohol and water soluble extractives 8.92% and 20.26%, respectively, sugar 17.75%, starch 22.97% and tannins 2.37%. Phytochemical evaluation revealed the presence of carbohydrate, alkaloids, flavonoids, saponins, tannins and sterol. Thin layer chromatography was carried out with different solvents and the best solvent system was chloroform and methanol in 80:20 ratio and revealed 12 spots with different Rf value under UV light 366λ. Conclusions: The results of the study can serve as a valuable source of information and provide suitable standards for identification of this plant material for future investigations and applications.

  13. Revisiting the debate on the relationship between display rules and performance: considering the explicitness of display rules.

    Science.gov (United States)

    Christoforou, Paraskevi S; Ashforth, Blake E

    2015-01-01

    We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.

  14. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks.

    Science.gov (United States)

    Norvell, Nicholas G; Korioth, Tom V; Cagna, David R; Versluis, Antheunis

    2018-02-08

    Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were

  15. A theoretical ovary position in link with the global anatomical ...

    African Journals Online (AJOL)

    anatomical structure of each human female body. Hassen ... pregnancy ovaries become really slightly displaced they would keep the proposed three- ... ovarian ligament, which anchors the ovary to the uterus; and the suspensory ligament,.

  16. SEM characterization of anatomical variation in chitin organization in insect and arthropod cuticles.

    Science.gov (United States)

    Chandran, Rakkiyappan; Williams, Lee; Hung, Albert; Nowlin, Kyle; LaJeunesse, Dennis

    2016-03-01

    The cuticles of insects and arthropods have some of the most diverse material properties observed in nature, so much so that it is difficult to imagine that all cutciles are primarily composed of the same two materials: a fibrous chitin network and a matrix composed of cuticle proteins. Various factors contribute to the mechanical and optical properties of an insect or arthropod cuticle including the thickness and composition. In this paper, we also identified another factor that may contribute to the optical, surface, and mechanical properties of a cuticle, i.e. the organization of chitin nanofibers and chitin fiber bundles. Self-assembled chitin nanofibers serve as the foundation for all higher order chitin structures in the cuticles of insects and other arthropods via interactions with structural cuticle proteins. Using a technique that enables the characterization of chitin organization in the cuticle of intact insects and arthropod exoskeletons, we demonstrate a structure/function correlation of chitin organization with larger scale anatomical structures. The chitin scaffolds in cuticles display an extraordinarily diverse set of morphologies that may reflect specific mechanical or physical properties. After removal of the proteinaceous and mineral matrix of a cuticle, we observe using SEM diverse nanoscale and micro scale organization of in-situ chitin in the wing, head, eye, leg, and dorsal and ventral thoracic regions of the periodical cicada Magicicada septendecim and in other insects and arthropods. The organization of chitin also appears to have a significant role in the organization of nanoscale surface structures. While microscale bristles and hairs have long been known to be chitin based materials formed as cellular extensions, we have found a nanostructured layer of chitin in the cuticle of the wing of the dog day annual cicada Tibicen tibicens, which may be the scaffold for the nanocone arrays found on the wing. We also use this process to examine

  17. Anatomic Mesenchymal Stem Cell-Based Engineered Cartilage Constructs for Biologic Total Joint Replacement

    Science.gov (United States)

    Saxena, Vishal; Kim, Minwook; Keah, Niobra M.; Neuwirth, Alexander L.; Stoeckl, Brendan D.; Bickard, Kevin; Restle, David J.; Salowe, Rebecca; Wang, Margaret Ye; Steinberg, David R.

    2016-01-01

    Cartilage has a poor healing response, and few viable options exist for repair of extensive damage. Hyaluronic acid (HA) hydrogels seeded with mesenchymal stem cells (MSCs) polymerized through UV crosslinking can generate functional tissue, but this crosslinking is not compatible with indirect rapid prototyping utilizing opaque anatomic molds. Methacrylate-modified polymers can also be chemically crosslinked in a cytocompatible manner using ammonium persulfate (APS) and N,N,N′,N′-tetramethylethylenediamine (TEMED). The objectives of this study were to (1) compare APS/TEMED crosslinking with UV crosslinking in terms of functional maturation of MSC-seeded HA hydrogels; (2) generate an anatomic mold of a complex joint surface through rapid prototyping; and (3) grow anatomic MSC-seeded HA hydrogel constructs using this alternative crosslinking method. Juvenile bovine MSCs were suspended in methacrylated HA (MeHA) and crosslinked either through UV polymerization or chemically with APS/TEMED to generate cylindrical constructs. Minipig porcine femoral heads were imaged using microCT, and anatomic negative molds were generated by three-dimensional printing using fused deposition modeling. Molded HA constructs were produced using the APS/TEMED method. All constructs were cultured for up to 12 weeks in a chemically defined medium supplemented with TGF-β3 and characterized by mechanical testing, biochemical assays, and histologic analysis. Both UV- and APS/TEMED-polymerized constructs showed increasing mechanical properties and robust proteoglycan and collagen deposition over time. At 12 weeks, APS/TEMED-polymerized constructs had higher equilibrium and dynamic moduli than UV-polymerized constructs, with no differences in proteoglycan or collagen content. Molded HA constructs retained their hemispherical shape in culture and demonstrated increasing mechanical properties and proteoglycan and collagen deposition, especially at the edges compared to the center of these

  18. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  19. Anatomically ordered tapping interferes more with one-digit addition than two-digit addition: a dual-task fMRI study.

    Science.gov (United States)

    Soylu, Firat; Newman, Sharlene D

    2016-02-01

    Fingers are used as canonical representations for numbers across cultures. In previous imaging studies, it was shown that arithmetic processing activates neural resources that are known to participate in finger movements. Additionally, in one dual-task study, it was shown that anatomically ordered finger tapping disrupts addition and subtraction more than multiplication, possibly due to a long-lasting effect of early finger counting experiences on the neural correlates and organization of addition and subtraction processes. How arithmetic task difficulty and tapping complexity affect the concurrent performance is still unclear. If early finger counting experiences have bearing on the neural correlates of arithmetic in adults, then one would expect anatomically and non-anatomically ordered tapping to have different interference effects, given that finger counting is usually anatomically ordered. To unravel these issues, we studied how (1) arithmetic task difficulty and (2) the complexity of the finger tapping sequence (anatomical vs. non-anatomical ordering) affect concurrent performance and use of key neural circuits using a mixed block/event-related dual-task fMRI design with adult participants. The results suggest that complexity of the tapping sequence modulates interference on addition, and that one-digit addition (fact retrieval), compared to two-digit addition (calculation), is more affected from anatomically ordered tapping. The region-of-interest analysis showed higher left angular gyrus BOLD response for one-digit compared to two-digit addition, and in no-tapping conditions than dual tapping conditions. The results support a specific association between addition fact retrieval and anatomically ordered finger movements in adults, possibly due to finger counting strategies that deploy anatomically ordered finger movements early in the development.

  20. An Investigation of Interval Management Displays

    Science.gov (United States)

    Swieringa, Kurt A.; Wilson, Sara R.; Shay, Rick

    2015-01-01

    NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to transition the most mature ATM technologies from the laboratory to the National Airspace System. One selected technology is Interval Management (IM), which uses onboard aircraft automation to compute speeds that help the flight crew achieve and maintain precise spacing behind a preceding aircraft. Since ATD-1 focuses on a near-term environment, the ATD-1 flight demonstration prototype requires radio voice communication to issue an IM clearance. Retrofit IM displays will enable pilots to both enter information into the IM avionics and monitor IM operation. These displays could consist of an interface to enter data from an IM clearance and also an auxiliary display that presents critical information in the primary field-of-view. A human-in-the-loop experiment was conducted to examine usability and acceptability of retrofit IM displays, which flight crews found acceptable. Results also indicate the need for salient alerting when new speeds are generated and the desire to have a primary field of view display available that can display text and graphic trend indicators.