WorldWideScience

Sample records for disordered multi-channel systems

  1. The random phase property and the Lyapunov spectrum for disordered multi-channel systems

    CERN Document Server

    Roemer, Rudolf A

    2009-01-01

    A random phase property establishing a link between quasi-one-dimensional random Schroedinger operators and full random matrix theory is advocated. Briefly summarized it states that the random transfer matrices placed into a normal system of coordinates act on the isotropic frames and lead to a Markov process with a unique invariant measure which is of geometric nature. On the elliptic part of the transfer matrices, this measure is invariant under the full hermitian symplectic group of the universality class under study. While the random phase property can up to now only be proved in special models or in a restricted sense, we provide strong numerical evidence that it holds in the Anderson model of localization. A main outcome of the random phase property is a perturbative calculation of the Lyapunov exponents which shows that the Lyapunov spectrum is equidistant and that the localization lengths for large systems in the unitary, orthogonal and symplectic ensemble differ by a factor 2 each. In an Anderson-And...

  2. Multi-channel automotive night vision system

    Science.gov (United States)

    Lu, Gang; Wang, Li-jun; Zhang, Yi

    2013-09-01

    A four-channel automotive night vision system is designed and developed .It is consist of the four active near-infrared cameras and an Mulit-channel image processing display unit,cameras were placed in the automobile front, left, right and rear of the system .The system uses near-infrared laser light source,the laser light beam is collimated, the light source contains a thermoelectric cooler (TEC),It can be synchronized with the camera focusing, also has an automatic light intensity adjustment, and thus can ensure the image quality. The principle of composition of the system is description in detail,on this basis, beam collimation,the LD driving and LD temperature control of near-infrared laser light source,four-channel image processing display are discussed.The system can be used in driver assistance, car BLIS, car parking assist system and car alarm system in day and night.

  3. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  4. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V.

    2016-05-03

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  5. Multi-channel medical imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Frangioni, John V.

    2016-05-03

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  6. Multi-channel gas-delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Rozenzon, Yan; Trujillo, Robert T.; Beese, Steven C.

    2016-09-13

    One embodiment of the present invention provides a gas-delivery system for delivering reaction gas to a reactor chamber. The gas-delivery system includes a main gas-inlet port for receiving reaction gases and a gas-delivery plate that includes a plurality of gas channels. A gas channel includes a plurality of gas holes for allowing the reaction gases to enter the reactor chamber from the gas channel. The gas-delivery system further includes a plurality of sub-gas lines coupling together the main gas-inlet port and the gas-delivery plate, and a respective sub-gas line is configured to deliver a portion of the received reaction gases to a corresponding gas channel.

  7. A multi-channel instrumentation system for biosignal recording.

    Science.gov (United States)

    Yu, Hong; Li, Pengfei; Xiao, Zhiming; Peng, Chung-Ching; Bashirullah, Rizwan

    2008-01-01

    This paper reports a highly integrated battery operated multi-channel instrumentation system intended for physiological signal recording. The mixed signal IC has been fabricated in standard 0.5microm 5V 3M-2P CMOS process and features 32 instrumentation amplifiers, four 8b SAR ADCs, a wireless power interface with Li-ion battery charger, low power bidirectional telemetry and FSM controller with power gating control for improved energy efficiency. The chip measures 3.2mm by 4.8mm and dissipates approximately 2.1mW when fully operational.

  8. Multi-Channel Retail Supply Chain Management: Fulfillment systems in Multi-Channel Retailing - Customer Expectations and Economic Performance

    OpenAIRE

    Lang, Gerald

    2010-01-01

    International audience; Increasingly, store-based retailers are opening an additional online sales channel and becoming multi-channel retailers. The integration of these different channels raises the question how to redefine the strategic marketing elements and the operations, as the two channels have different constraints and require different competences. This multi-channel retailing has major impacts on the operations and the supply-chain management. Order fulfillment for the customers usi...

  9. Solving non-Markovian open quantum systems with multi-channel reservoir coupling

    CERN Document Server

    Broadbent, Curtis J; Yu, Ting; Eberly, Joseph H

    2011-01-01

    We extend the non-Markovian quantum state diffusion (QSD) equation to open quantum systems which exhibit multi-channel coupling to a harmonic oscillator reservoir. Open quantum systems which have multi-channel reservoir coupling are those in which canonical transformation of reservoir modes cannot reduce the number of reservoir operators appearing in the interaction Hamiltonian to one. We show that the non-Markovian QSD equation for multi-channel reservoir coupling can, in some cases, lead to an exact master equation which we derive. We then derive the exact master equation for the three-level system in a vee-type configuration which has multi-channel reservoir coupling and give the analytical solution. Finally, we examine the evolution of the three-level vee-type system with generalized Ornstein-Uhlenbeck reservoir correlations numerically.

  10. Solving non-Markovian open quantum systems with multi-channel reservoir coupling

    Science.gov (United States)

    Broadbent, Curtis J.; Jing, Jun; Yu, Ting; Eberly, Joseph H.

    2012-08-01

    We extend the non-Markovian quantum state diffusion (QSD) equation to open quantum systems which exhibit multi-channel coupling to a harmonic oscillator reservoir. Open quantum systems which have multi-channel reservoir coupling are those in which canonical transformation of reservoir modes cannot reduce the number of reservoir operators appearing in the interaction Hamiltonian to one. We show that the non-Markovian QSD equation for multi-channel reservoir coupling can, in some cases, lead to an exact master equation which we derive. We then derive the exact master equation for the three-level system in a vee-type configuration which has multi-channel reservoir coupling and give the analytical solution. Finally, we examine the evolution of the three-level vee-type system with generalized Ornstein-Uhlenbeck reservoir correlations numerically.

  11. Advanced Modular, Multi-Channel, High Speed Fiber Optic Sensing System for Acoustic Emissions Monitoring Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Intelligent Fiber Optic Systems Corporation (IFOS) proposes to prove the feasibility of innovations based on ultra-light-weight, ultra-high-speed, multi-channel,...

  12. Solving non-Markovian open quantum systems with multi-channel reservoir coupling

    Energy Technology Data Exchange (ETDEWEB)

    Broadbent, Curtis J., E-mail: curtis.broadbent@rochester.edu [Rochester Theory Center, and Department of Physics and Astronomy, University of Rochester, Rochester, NY 14627 (United States); Jing, Jun; Yu, Ting [Center for Controlled Quantum Systems, and the Department of Physics and Engineering Physics, Stevens Institute of Technology, Hoboken, NJ 07030 (United States); Eberly, Joseph H. [Rochester Theory Center, and Department of Physics and Astronomy, University of Rochester, Rochester, NY 14627 (United States)

    2012-08-15

    We extend the non-Markovian quantum state diffusion (QSD) equation to open quantum systems which exhibit multi-channel coupling to a harmonic oscillator reservoir. Open quantum systems which have multi-channel reservoir coupling are those in which canonical transformation of reservoir modes cannot reduce the number of reservoir operators appearing in the interaction Hamiltonian to one. We show that the non-Markovian QSD equation for multi-channel reservoir coupling can, in some cases, lead to an exact master equation which we derive. We then derive the exact master equation for the three-level system in a vee-type configuration which has multi-channel reservoir coupling and give the analytical solution. Finally, we examine the evolution of the three-level vee-type system with generalized Ornstein-Uhlenbeck reservoir correlations numerically. - Highlights: Black-Right-Pointing-Pointer The concept of multi-channel vs. single-channel reservoir coupling is rigorously defined. Black-Right-Pointing-Pointer The non-Markovian quantum state diffusion equation for arbitrary multi-channel reservoir coupling is derived. Black-Right-Pointing-Pointer An exact time-local master equation is derived under certain conditions. Black-Right-Pointing-Pointer The analytical solution to the three-level system in a vee-type configuration is found. Black-Right-Pointing-Pointer The evolution of the three-level system under generalized Ornstein-Uhlenbeck noise is plotted for many parameter regimes.

  13. Study of Effect of Raw Data Compression on Azimuth Multi-channel SAR System

    Directory of Open Access Journals (Sweden)

    Zhao Yao

    2017-08-01

    Full Text Available An effective way to achieve High Resolution and Wide Swath (HRWS imaging capability is the multi-channel technique in azimuth. Improved resolution and swath can dramatically increase the volume of echo data in the SAR system. However, the onboard data storage and data-transmission bandwidth are limited, so data compression technique is typically used to reduce the volume of echo data. To study the effect of raw data compression on the azimuth multi-channel SAR system, in this paper, we establish a multi-channel SAR signal model based on data compression. We then derive and analyze the effects of data compression on the Signal-to-Noise Ratio (SNR scaling factor of the multi-channel SAR system and quantization noise. Finally, we verify the validity of the proposed model and analysis results using simulation and real data and discuss the effect of data compression on the Peek-to-Ghost Ratio (PGR. The results of this paper provide an important theoretical basis for the choice of compression method in the multi-channel SAR system.

  14. Multi-channel holographic birfurcative neural network system for real-time adaptive EOS data analysis

    Science.gov (United States)

    Liu, Hua-Kuang; Diep, J.; Huang, K.

    1991-01-01

    Viewgraphs on multi-channel holographic bifurcative neural network system for real-time adaptive Earth Observing System (EOS) data analysis are presented. The objective is to research and develop an optical bifurcating neuromorphic pattern recognition system for making optical data array comparisons and to evaluate the use of the system for EOS data classification, reduction, analysis, and other applications.

  15. A microprocessor based, multi-channel low-temperature monitoring system

    NARCIS (Netherlands)

    Kuiper, B.W.; Dijk, van M.H.H.

    1982-01-01

    A multi-channel low-temperature monitoring system and its design considerations are presented. The system is microprocessor based and specially designed to interface thermoresistive sensors in cryogenic experiments. The system can be easily expanded to accept any type of physical transducer and to p

  16. Task Dependent Prefrontal Dysfunction in Persons with Asperger's Disorder Investigated with Multi-Channel Near-Infrared Spectroscopy

    Science.gov (United States)

    Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Hashimoro, Ryuichiro; Kanai, Chieko; Watanabe, Hiromi; Yamasue, Hidenori; Kawakubo, Yuki; Kato, Nobumasa

    2011-01-01

    Dysfunction of the prefrontal cortex has been previously reported in individuals with Asperger's disorder. In the present study, we used multi-channel near-infrared spectroscopy (NIRS) to detect changes in the oxygenated hemoglobin concentration ([oxy-Hb]) during two verbal fluency tasks. The subjects were 20 individuals with Asperger's disorder…

  17. Task Dependent Prefrontal Dysfunction in Persons with Asperger's Disorder Investigated with Multi-Channel Near-Infrared Spectroscopy

    Science.gov (United States)

    Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Hashimoro, Ryuichiro; Kanai, Chieko; Watanabe, Hiromi; Yamasue, Hidenori; Kawakubo, Yuki; Kato, Nobumasa

    2011-01-01

    Dysfunction of the prefrontal cortex has been previously reported in individuals with Asperger's disorder. In the present study, we used multi-channel near-infrared spectroscopy (NIRS) to detect changes in the oxygenated hemoglobin concentration ([oxy-Hb]) during two verbal fluency tasks. The subjects were 20 individuals with Asperger's disorder…

  18. SAR++: A Multi-Channel Scalable and Reconfigurable SAR System

    DEFF Research Database (Denmark)

    Høeg, Flemming; Christensen, Erik Lintz

    2002-01-01

    SAR++ is a technology program aiming at developing know-how and technology needed to design the next generation civilian SAR systems. Technology has reached a state, which allows major parts of the digital subsystem to be built using custom-off-the-shelf (COTS) components. A design goal is to des......SAR++ is a technology program aiming at developing know-how and technology needed to design the next generation civilian SAR systems. Technology has reached a state, which allows major parts of the digital subsystem to be built using custom-off-the-shelf (COTS) components. A design goal...... is to design a modular, scalable and reconfigurable SAR system using such components, in order to ensure maximum flexibility for the users of the actual system and for future system updates. Having these aspects in mind the SAR++ system is presented with focus on the digital subsystem architecture...... and the analog to digital interface....

  19. Multi-Channel Retailing

    Directory of Open Access Journals (Sweden)

    Dirk Morschett, Dr.,

    2005-01-01

    Full Text Available Multi-channel retailing entails the parallel use by retailing enterprises of several sales channels. The results of an online buyer survey which has been conducted to investigate the impact of multi-channel retailing (i.e. the use of several retail channels by one retail company on consumer behaviour show that the frequently expressed concern that the application of multi-channel systems in retailing would be associated with cannibalization effects, has proven unfounded. Indeed, the appropriate degree of similarity, consistency, integration and agreement achieves the exact opposite. Different channels create different advantages for consumers. Therefore the total benefit an enterprise which has a multi-channel system can offer to its consumers is larger, the greater the number of available channels. The use of multi-channel systems is associated with additional purchases in the different channels. Such systems are thus superior to those offering only one sales channel to their customers. Furthermore, multi-channel systems with integrated channels are superior to those in which the channels are essentially autonomous and independent of one another. In integrated systems, consumers can achieve synergy effects in the use of sales-channel systems. Accordingly, when appropriately formulated, multi-channel systems in retailing impact positively on consumers. They use the channels more frequently, buy more from them and there is a positive customer-loyalty impact. Multi-channel systems are strategic options for achieving customer loyalty, exploiting customer potential and for winning new customers. They are thus well suited for approaching differing and varied target groups.

  20. Development of programmable multi-channel earth resistivity system

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Ki; Choi, Jong Ho; Park, In Wha [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    Maximum 256 channel digital-stacking automatic electrical earth resistivity meter is upgrade-developed and field-tested with two commercially available systems (OYO McOHM and ABEM Terrameter) for Schlumberger vertical sounding and dipole-dipole arrays. The results of three systems are very well coincident for several dummy resistors and Schlumberger array in field site. The developed system K-Ohm shows even more reasonable quality data in sensitive dipole-dipole array measurements in comparison with the electrical survey instruments of digital stacking type manufactured by other countries. New Important features of upgraded programmable K-Ohm system are as follows ; 1) Auto-electrode-switching control by Notebook printer port, 2) receiving signal measurement by Notebook serial port, 3) interactive automatic dipole-dipole measurement software with two apparent resistivity sections compared in one Notebook display to minimize noisy data in field, 4) auto-saved field memo at any time appending to acquired data, 5) max 500 V{sub p-p} 500 mA transmitter (measuring cycle S/W programmable), 6) low-drift sigma - delta 24 bit A/D 0.0015 % linearity error with zero-offset and full - scale gain autocalibration, 7) DC 12 v operated and TX-RX 7,000 V optical-isolated, 8) electrodes grounding auto-tested, user-oriented any array sequential programmable control software. Further study will be focused on higher power TX and stand alone TX-RX system, and micro-resistivity system for in-borehole resistivity imaging. (author). 8 refs., 9 figs.

  1. Multi-channel data acquisition system with absolute time synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Włodarczyk, Przemysław, E-mail: pan.wlodarczyk@uj.edu.pl [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland); Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Pustelny, Szymon, E-mail: pustelny@uj.edu.pl [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Budker, Dmitry [Department of Physics, University of California at Berkeley, Berkeley, California 94720-7300 (United States); Lipiński, Marcin [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland)

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics – GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  2. Antenna set for multi-channel TV system

    OpenAIRE

    Gryanik, M. V.; Ilyinov, M. D.; Pasechnik, S. G.

    1995-01-01

    One of the directions in the development of the urban TV networks is switching to the non-traditional frequency ranges. In particular, this is the range, which is widely used in systems of direct satellite TV broadcasting. The choice of this range can be explained by the saturation of commercial market of receiving equipment such as converters and tuners first of all. Transmitting antenna for such a network should have a circular horizontal plane directional pattern (DP) and have as high gain...

  3. Multi-Channel-Learning (MCL - Ein Referenzmodell für Learning-Content-Systeme (LCS

    Directory of Open Access Journals (Sweden)

    Jan vom Brocke

    2005-12-01

    Full Text Available Lerneinheiten müssen stark variierenden Anforderungen gerecht werden. Neben unterschiedlichen Lerntypen spielen vor allem auch die Umfeldbedingungen eine wesentliche Rolle, in denen Lernprozesse stattfinden. Faktoren wie z. B. die Tagesform führen letztlich dazu, dass nicht einmal für eine einzelne Person konstante Lernpräferenzen herrschen.Mit diesem Beitrag wird vorgeschlagen, zur Lösung des Problems einer Mehrkanalstrategie zu folgen. Allerdings sind spezifische Eigenschaften von Learning-Content-Systemen (LCS notwendig, um ein sog. Multi-Channel-Learning (MCL zu ermöglichen. Diese Eigenschaften werden im Beitrag anhand von Informationsmodellen beschrieben werden. Sie sollen als Referenzmodell dienen, das sowohl bei der Entwicklung als auch bei der Auswahl und Anpassung von LCS hilfreich sein kann.Das Referenzmodell wird deduktiv abgeleitet und anhand praktischer Anwendungen geprüft. Vorgestellt werden sowohl Anwendungs- als auch Organisationssysteme, die nach dem Modell realisiert worden sind. Auf dieser Grundlage kann schließlich eine Nutzenabschätzung des Modells für das Multi-Channel-Learnings vorgenommen werden.This paper presents a reference model for the design of learning-content systems (LCS according to a multi-channel strategy.The model comes into play when various requirements for editing learning contents need to be considered. Both the learner's preferences as well as the situative varieties of the learner's context are of utmost importance for the construction of appropriate learning units. One strategy in order to meet these requirements is the editing of content according to a multi-channel strategy. That way, learners can decide via which channel they prefer to deal with the content in a specific situation. The reference model for MCL that is provided with this paper, supports the implementation of such strategies. It gives a description of essential characteristics of LCS in order to facilitate Multi-Channel

  4. A New Dual-electrode and Multi-channel Electrochemical DetectionSystem for Capillary Electrophoresis

    Institute of Scientific and Technical Information of China (English)

    Bing Yi YANG; Jin Yuan MO; Rong LAI

    2004-01-01

    A new type of dual-electrode and multi-channel electrochemical detection technology for capillary electrophoresis is described in this paper. Two detectors(the amperometric detector and the conductometric detector)or two conductometric detectors are connected to the same capillary electrophoresis system. The whole system possesses the advantages of the two electrochemical detectors including sparing time,improving the analytical speed and expanding the sample range.The working electrode and detector cell are handled easily.The system was applied to sample detection with satisfactory results.

  5. On a multi-channel transportation loss system with controlled input and controlled service

    Directory of Open Access Journals (Sweden)

    Jewgeni Dshalalow

    1987-01-01

    Full Text Available A multi-channel loss queueing system is investigated. The input stream is a controlled point process. The service in each of m parallel channels depends on the state of the system at certain moments of time when input and service may be controlled. To obtain explicitly the limiting distribution of the main process (Zt (the number of busy channels in equilibrium, an auxiliary three dimensional process with two additional components (one of them is a semi-Markov process is treated as semi-regenerative process. An optimization problem is discussed. Simple expressions for an objective function are derived.

  6. Optical-network-connected multi-channel 96-GHz-band distributed radar system

    Science.gov (United States)

    Kanno, Atsushi; Kuri, Toshiaki; Kawanishi, Tetsuya

    2015-05-01

    The millimeter-wave (MMW) radar is a promising candidate for high-precision imaging because of its short wavelength and broad range of available bandwidths. In particular in the frequency range of 92-100 GHz, which is regulated for radiolocation, an atmospheric attenuation coefficient less than 1 dB/km limits the imaging range. Therefore, a combination of MMW radar and distributed antenna system directly connected to optical fiber networks can realize both high-precision imaging and large-area surveillance. In this paper, we demonstrate a multi-channel MMW frequency-modulated continuous-wave distributed radar system connected to an analog radio-over-fiber network.

  7. A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.

    Science.gov (United States)

    Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco

    2013-01-01

    Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.

  8. Principle of Line Configuration and Monte-Carlo Simulation for Shared Multi-Channel System

    Institute of Scientific and Technical Information of China (English)

    MIAO Changyun; DAI Jufeng; BAI Zhihui

    2005-01-01

    Based on the steady-state solution of finite-state birth and death process, the principle of line configuration for shared multi-channel system is analyzed. Call congestion ratio equation and channel utilization ratio equation are deduced, and visualized data analysis is presented. The analy-sis indicates that, calculated with the proposed equations, the overestimate for call congestion ratio and channel utilization ratio can be rectified, and thereby the cost of channels can be saved by 20% in a small system.With MATLAB programming, line configuration methods are provided. In order to generally and intuitively show the dynamic running of the system, and to analyze,promote and improve it, the system is simulated using M/M/n/n/m queuing model and Monte-Carlo method. In addition, the simulation validates the correctness of the theoretical analysis and optimizing configuration method.

  9. Multi-Channel SQUID System for MEG and Ultra-Low-Field MRI

    CERN Document Server

    Zotev, V S; Volegov, P L; Sandin, H J; Espy, M A; Mosher, J C; Urbaitis, A V; Newman, S G; Zotev, Vadim S.; Matlachov, Andrei N.; Volegov, Petr L.; Sandin, Henrik J.; Espy, Michelle A.; Mosher, John C.; Urbaitis, Algis V.; Newman, Shaun G.; Jr, Robert H. Kraus

    2007-01-01

    A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8 fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with pre-polarization. The system's MEG performance was demonstrated by measurements of auditory evoked response. The system was also used to obtain a multi-channel 2-D image of a whole human hand at the measurement field of 46 microtesla with 3 by 3 mm resolution.

  10. Development of a portable multi-channel system for plant physiological signal recording

    Directory of Open Access Journals (Sweden)

    Ting Li

    2016-06-01

    Full Text Available Bioelectrical signals can reflect physiological state of organs or tissues in plants and have a significant potential value in research of plant stress tolerance. In order to study the relationship between environment factors and electrical signals in plant, a portable multi-channel physiological signal acquisition system which relevant in plant physiology research was developed. Environment parameters and electrical signals can be measured in different channels by the acquisition system simultaneously and the measurement data will be displayed in an embedded integrated touch screen which is the system processing core. The system was validated to be stable and reliable after the calibration and repeated experiments of recording electrical signals in Helianthus annuus L.

  11. A Multi-Channel Method for Detecting Periodic Forced Oscillations in Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Follum, James D.; Tuffner, Francis K.

    2016-11-14

    Forced oscillations in electric power systems are often symptomatic of equipment malfunction or improper operation. Detecting and addressing the cause of the oscillations can improve overall system operation. In this paper, a multi-channel method of detecting forced oscillations and estimating their frequencies is proposed. The method operates by comparing the sum of scaled periodograms from various channels to a threshold. A method of setting the threshold to specify the detector's probability of false alarm while accounting for the correlation between channels is also presented. Results from simulated and measured power system data indicate that the method outperforms its single-channel counterpart and is suitable for real-world applications.

  12. Power Allocation and Spectrum Sharing in Multi-User, Multi-Channel Systems with Strategic Users

    CERN Document Server

    Kakhbod, Ali

    2010-01-01

    We consider the decentralized power allocation and spectrum sharing problem in multi-user, multi-channel systems with strategic users. We present a mechanism/game form that has the following desirable features. (1) It is individually rational. (2) It is budget balanced at every Nash equilibrium of the game induced by the game form as well as off equilibrium. (3) The allocation corresponding to every Nash equilibrium (NE) of the game induced by the mechanism is a Lindahl allocation, that is a weakly Pareto optimal allocation. Our proposed game form/mechanism achieves all the above desirable properties without any assumption about, concavity, differentiability, monotonicity, or quasi-linearity of the users' utility functions.

  13. Multi-Channel Autonomous Information System Performance with Positional Signal State Analyzers at the Channel Outputs

    Directory of Open Access Journals (Sweden)

    V. K. Hohlov

    2016-01-01

    Full Text Available The article presents a statement of technique to research performances of multi-channel combo standalone information systems with positional analyzers of the signal states at the channel outputs. In most cases, in considered multi-channel systems there has been impossible to coincide in time the random moments of signals coming from the objects through various channels in all ways of encounter environment and conditions of practical application. The analyzer makes decision on the signal using the discrete operations on the quantized signals of the certain duration from the channel outputs. The analyzer performance is described by a set of Boolean algebra functions defined for all possible states of the signals at the outputs of the channels, and in the general case is specified in a perfect disjunctive normal form. To determine the validity or falsity of functions of the algebra of logics, which are calculated statements concerning the available or unavailable useful signal at the system input, on the authority of the Poretsky’s theorem and the theory of coincidence in time of the random pulse flow of the channels response because of uncorrelated and correlated noise, are obtained dependences to calculate the probabilities of false alarms and omissions of the signals in discrete combined systems. It is shown that the flows of false alarms because of noise at the channel outputs in the system are Poisson streams. On the basis of the ordinary Poisson flows the paper justifies the relationships for calculating the false alarms of the system with uncorrelated and correlated noise in the channels. The paper also justifies the relationships for performance of multichannel combined systems with positional analyzers of the channels states. Based on the obtained relationships was calculated the average coincidence frequency of the extended pulses of the channel response in a dualchannel system, depending on the noise cross-correlation coefficient with

  14. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  15. A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells.

    Science.gov (United States)

    Calderón, Antonio José; González, Isaías; Calderón, Manuel; Segura, Francisca; Andújar, José Manuel

    2016-03-09

    In this work a new, scalable and low cost multi-channel monitoring system for Polymer Electrolyte Fuel Cells (PEFCs) has been designed, constructed and experimentally validated. This developed monitoring system performs non-intrusive voltage measurement of each individual cell of a PEFC stack and it is scalable, in the sense that it is capable to carry out measurements in stacks from 1 to 120 cells (from watts to kilowatts). The developed system comprises two main subsystems: hardware devoted to data acquisition (DAQ) and software devoted to real-time monitoring. The DAQ subsystem is based on the low-cost open-source platform Arduino and the real-time monitoring subsystem has been developed using the high-level graphical language NI LabVIEW. Such integration can be considered a novelty in scientific literature for PEFC monitoring systems. An original amplifying and multiplexing board has been designed to increase the Arduino input port availability. Data storage and real-time monitoring have been performed with an easy-to-use interface. Graphical and numerical visualization allows a continuous tracking of cell voltage. Scalability, flexibility, easy-to-use, versatility and low cost are the main features of the proposed approach. The system is described and experimental results are presented. These results demonstrate its suitability to monitor the voltage in a PEFC at cell level.

  16. A real-time multi-channel monitoring system for stem cell culture process.

    Science.gov (United States)

    Xicai Yue; Drakakis, E M; Lim, M; Radomska, A; Hua Ye; Mantalaris, A; Panoskaltsis, N; Cass, A

    2008-06-01

    A novel, up to 128 channels, multi-parametric physiological measurement system suitable for monitoring hematopoietic stem cell culture processes and cell cultures in general is presented in this paper. The system aims to measure in real-time the most important physical and chemical culture parameters of hematopoietic stem cells, including physicochemical parameters, nutrients, and metabolites, in a long-term culture process. The overarching scope of this research effort is to control and optimize the whole bioprocess by means of the acquisition of real-time quantitative physiological information from the culture. The system is designed in a modular manner. Each hardware module can operate as an independent gain programmable, level shift adjustable, 16 channel data acquisition system specific to a sensor type. Up to eight such data acquisition modules can be combined and connected to the host PC to realize the whole system hardware. The control of data acquisition and the subsequent management of data is performed by the system's software which is coded in LabVIEW. Preliminary experimental results presented here show that the system not only has the ability to interface to various types of sensors allowing the monitoring of different types of culture parameters. Moreover, it can capture dynamic variations of culture parameters by means of real-time multi-channel measurements thus providing additional information on both temporal and spatial profiles of these parameters within a bioreactor. The system is by no means constrained in the hematopoietic stem cell culture field only. It is suitable for cell growth monitoring applications in general.

  17. A dynamic multi-channel speech enhancement system for distributed microphones in a car environment

    Science.gov (United States)

    Matheja, Timo; Buck, Markus; Fingscheidt, Tim

    2013-12-01

    Supporting multiple active speakers in automotive hands-free or speech dialog applications is an interesting issue not least due to comfort reasons. Therefore, a multi-channel system for enhancement of speech signals captured by distributed distant microphones in a car environment is presented. Each of the potential speakers in the car has a dedicated directional microphone close to his position that captures the corresponding speech signal. The aim of the resulting overall system is twofold: On the one hand, a combination of an arbitrary pre-defined subset of speakers' signals can be performed, e.g., to create an output signal in a hands-free telephone conference call for a far-end communication partner. On the other hand, annoying cross-talk components from interfering sound sources occurring in multiple different mixed output signals are to be eliminated, motivated by the possibility of other hands-free applications being active in parallel. The system includes several signal processing stages. A dedicated signal processing block for interfering speaker cancellation attenuates the cross-talk components of undesired speech. Further signal enhancement comprises the reduction of residual cross-talk and background noise. Subsequently, a dynamic signal combination stage merges the processed single-microphone signals to obtain appropriate mixed signals at the system output that may be passed to applications such as telephony or a speech dialog system. Based on signal power ratios between the particular microphone signals, an appropriate speaker activity detection and therewith a robust control mechanism of the whole system is presented. The proposed system may be dynamically configured and has been evaluated for a car setup with four speakers sitting in the car cabin disturbed in various noise conditions.

  18. MODELING OF THE PRIORITY SCHEDULING INPUT-LINE GROUP OUTPUT WITH MULTI-CHANNEL IN ATM EXCHANGE SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this paper, an extended Kendall model for the priority scheduling input-line group output with multi-channel in Asynchronous Transfer Mode (ATM) exchange system is proposed and then the mean method is used to model mathematically the non-typical non-anticipative PRiority service (PR) model. Compared with the typical and non-anticipative PR model, it expresses the characteristics of the priority scheduling input-line group output with multi-channel in ATM exchange system. The simulation experiment shows that this model can improve the HOL block and the performance of input-queued ATM switch network dramatically. This model has a better developing prospect in ATM exchange system.

  19. Take time to make time : What to consider when managing multi-channel sales systems with the objective to increase sales efficiency

    OpenAIRE

    Alm, Ragnar; KYRÖNLAHTI, RUDY

    2016-01-01

    Traditional sales systems have been disrupted by technological developments. In order to  adapt, companies are changing the way they interact with their customers in business-to-business markets. In the last three decades, multi-channel strategies have spurred the proliferation of different sales channels and new ways of managing sales systems. The purpose of this research was to investigate what should be considered when managing multi-channel sales systems with the objective of increasing s...

  20. A DVB-RCS Multi-Channel, Multi-Frequency Demodulator Based on a Multi-Tasking Hardware-Software Architecture Using a System on Programmable Chip Technology

    Science.gov (United States)

    van Doninck, A.; Dendoncker, M.; Adriaensen, F.; Delbeke, P.; Rolle, A.; Craey, T.; Krekels, S.

    : This paper highlights a multi-channel, multi-frequency DVB-RCS compatible burst demodulator implementation in a System On Programmable Chip (SOPC) technology. The core of the demodulator architecture is a SOPC device with an ARM processor located internally in FPGA. The ARM processor performs the hard real time signal processing functions and is supported by a COTS standard PC based processor module running Linux/RT-Linux for the non-hard real-time demodulator functions. The implemented architecture differs completely from classic multi-channel solutions, in which the multi- channel functionality is realised by means of a multiple instantiation of the entire demodulator. The paper also discusses the followed methodology for the SOPC design. Keywords: DVB-RCS, multi-channel, multi-frequency, SOPC, FPGA, ARM, RT-Linux

  1. TEACHERS’ AND LEARNERS PERCEPTIONS OF LANGUAGE TEACHING STRATEGIES IN MULTI CHANNEL LEARNING SYSTEM

    Directory of Open Access Journals (Sweden)

    Clara Herlina Karjo

    2011-07-01

    strategies employed by Binus English teachers and second, to find out the intersection between teachers and students regarding the teaching strategies employed in the classroom. Using questionnaires for teachers and students, this study examined the frequency of strategy used by students and teachers. The results showed that teachers and students had different perceptions on the strategies/activities that occurred in the classroom. The implications of these results for the teaching/learning situation are discussed. Keywords: multi channel learning, teaching strategies, perception, teachers, students

  2. Multi-channel purge and trap system coupled with ion chromatography for the determination of alkylamines in cosmetics.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke; Luo, Zhibin; Zhu, Binghui

    2012-02-17

    A new multi-channel purge and trap system coupled with ion chromatography for the determination of six alkylamines in cosmetics was developed. The proposed method, based on purge and trap of the volatile alkylamines, involved in a miniaturization and multi-channel integration of classical steam distillation and a simple approach for routine labs. The procedure was rapidly achieved within 10 min and the matrix interferences could be effectively eliminated. Sample pretreatment frequency was higher than 40 h(-1). The linear ranges were 0.1-15 mg L(-1) and the detection limits varied from 0.023 to 0.038 mg L(-1). This method was successfully utilized to determine the amounts of alkylamines in cosmetics with recoveries ranging from 80.3 to 105.5% and the relative standard deviations (RSDs) ranging from 0.78 to 7.5%. It was proved to be accurate, time-saving, and suitable for the determination of large numbers of cosmetics in a short time.

  3. An Adaptive Multi-channel P2P Video-on-Demand System using Plug-and-Play Helpers

    CERN Document Server

    Zhang, Hao; Parekh, Abhay; Ramchandran, Kannan

    2010-01-01

    We present a multi-channel P2P Video-on-Demand (VoD) system using "plug-and-play" helpers. Helpers are heterogenous "micro-servers" with limited storage, bandwidth and number of users they can serve simultaneously. Our proposed system has the following salient features: (1) it minimizes the server load; (2) it is distributed, and requires little or no maintenance overhead and which can easily adapt to system dynamics; and (3) it is adaptable to varying supply and demand patterns across multiple video channels irrespective of video popularity. Our proposed solution jointly optimizes over helper-user topology, video storage allocation and bandwidth allocation. The combinatorial nature of the problem and the system demand for distributed algorithms makes the problem uniquely challenging. By utilizing Lagrangian decomposition and Markov chain approximation based arguments, we address this challenge by designing two distributed algorithms running in tandem: a primal-dual storage and bandwidth allocation algorithm ...

  4. An S-FSCW Based Multi-Channel Reader System for Beamforming Applications using Surface Acoustic Wave Sensors

    Directory of Open Access Journals (Sweden)

    C. Pfeffer

    2011-12-01

    Full Text Available Interrogating multiple surface acoustic wave (SAW sensors located within the same radar beam require techniques to separate the multiple superposing SAW sensor responses. The presented multi-channel reader features four parallel transceiver channels, which are based on the switched frequency-stepped continuous-wave principle and high-speed parallelized baseband electronics. Thus classical beamforming applications including angle of arrival measurement of single SAW tags and the angular separation of multiple SAW sensors are presented and compared to a multiple-input multiple-output (MIMO approach. Due to the larger virtual array in the MIMO approach a larger aperture can be synthesized, which leads to significantly better angular separation results. The level analysis for the given system is verified by baseband-power measurements at different readout distances, considering the hardware parameters as well as the free-space propagation aspects. Finally measurements assess the maximum interrogation distance for the system.

  5. New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

    Science.gov (United States)

    Timofeev, Andrey V.; Egorov, Dmitry V.

    2016-06-01

    This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called "The Weighing of Inversely as Lipschitz Constants" (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

  6. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We b

  7. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We

  8. Development and field example of multi channel surface wave data acquisition and processing system (SWS-1); Multi channel hyomenha data shutoku shori system (SWS-1) no kaihatsu to jikkenrei

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y. [Huashui Institute of Geophysical Exploration, (China); Wang, Z. [Bureauof Engineering MGMR, (China); Zhang, Z [STG Corp., (China); Tanaka, Y.

    1996-05-01

    A report is given here about the use of a newly-developed multi-channel surface wave data acquisition and processing system different from the conventional surface wave exploration device. This system enables the on-site pickup of a dispersion curve out of the multi-component surface wave data and, in the analysis of underground structure, performs the forward modeling and inversion. The system, furthermore, acquires and analyzes the data obtained from reflection earthquake exploration and constant microtremor observation. During a survey conducted along the highway from Port Ren-un to Xuzhou, China, estimation of the basement boundary was made by use of dynamite, and what was obtained agreed with the result of boring though with an error of 3m. In addition, this system could probe levels deeper than 100m using the instantaneous Rayleigh wave exploration method. This system and the conventional surface exploration device were compared in a soft ground in Fukui Prefecture, the former using a 10kg hammer and the latter using a 350kg exciter, when it was verified that the results produced by both techniques excellently agree with the geologic columnar section and changes in the N-value. 4 refs., 4 figs.

  9. Research on multi - channel interactive virtual assembly system for power equipment under the “VR+” era

    Science.gov (United States)

    Ren, Yilong; Duan, Xitong; Wu, Lei; He, Jin; Xu, Wu

    2017-06-01

    With the development of the “VR+” era, the traditional virtual assembly system of power equipment has been unable to satisfy our growing needs. In this paper, based on the analysis of the traditional virtual assembly system of electric power equipment and the application of VR technology in the virtual assembly system of electric power equipment in our country, this paper puts forward the scheme of establishing the virtual assembly system of power equipment: At first, we should obtain the information of power equipment, then we should using OpenGL and multi texture technology to build 3D solid graphics library. After the completion of three-dimensional modeling, we can use the dynamic link library DLL package three-dimensional solid graphics generation program to realize the modularization of power equipment model library and power equipment model library generated hidden algorithm. After the establishment of 3D power equipment model database, we set up the virtual assembly system of 3D power equipment to separate the assembly operation of the power equipment from the space. At the same time, aiming at the deficiency of the traditional gesture recognition algorithm, we propose a gesture recognition algorithm based on improved PSO algorithm for BP neural network data glove. Finally, the virtual assembly system of power equipment can really achieve multi-channel interaction function.

  10. Equalization enhanced phase noise in Nyquist-spaced superchannel transmission systems using multi-channel digital back-propagation

    Science.gov (United States)

    Xu, Tianhua; Liga, Gabriele; Lavery, Domaniç; Thomsen, Benn C.; Savory, Seb J.; Killey, Robert I.; Bayvel, Polina

    2015-09-01

    Superchannel transmission spaced at the symbol rate, known as Nyquist spacing, has been demonstrated for effectively maximizing the optical communication channel capacity and spectral efficiency. However, the achievable capacity and reach of transmission systems using advanced modulation formats are affected by fibre nonlinearities and equalization enhanced phase noise (EEPN). Fibre nonlinearities can be effectively compensated using digital back-propagation (DBP). However EEPN which arises from the interaction between laser phase noise and dispersion cannot be efficiently mitigated, and can significantly degrade the performance of transmission systems. Here we report the first investigation of the origin and the impact of EEPN in Nyquist-spaced superchannel system, employing electronic dispersion compensation (EDC) and multi-channel DBP (MC-DBP). Analysis was carried out in a Nyquist-spaced 9-channel 32-Gbaud DP-64QAM transmission system. Results confirm that EEPN significantly degrades the performance of all sub-channels of the superchannel system and that the distortions are more severe for the outer sub-channels, both using EDC and MC-DBP. It is also found that the origin of EEPN depends on the relative position between the carrier phase recovery module and the EDC (or MC-DBP) module. Considering EEPN, diverse coding techniques and modulation formats have to be applied for optimizing different sub-channels in superchannel systems.

  11. Equalization enhanced phase noise in Nyquist-spaced superchannel transmission systems using multi-channel digital back-propagation.

    Science.gov (United States)

    Xu, Tianhua; Liga, Gabriele; Lavery, Domaniç; Thomsen, Benn C; Savory, Seb J; Killey, Robert I; Bayvel, Polina

    2015-09-14

    Superchannel transmission spaced at the symbol rate, known as Nyquist spacing, has been demonstrated for effectively maximizing the optical communication channel capacity and spectral efficiency. However, the achievable capacity and reach of transmission systems using advanced modulation formats are affected by fibre nonlinearities and equalization enhanced phase noise (EEPN). Fibre nonlinearities can be effectively compensated using digital back-propagation (DBP). However EEPN which arises from the interaction between laser phase noise and dispersion cannot be efficiently mitigated, and can significantly degrade the performance of transmission systems. Here we report the first investigation of the origin and the impact of EEPN in Nyquist-spaced superchannel system, employing electronic dispersion compensation (EDC) and multi-channel DBP (MC-DBP). Analysis was carried out in a Nyquist-spaced 9-channel 32-Gbaud DP-64QAM transmission system. Results confirm that EEPN significantly degrades the performance of all sub-channels of the superchannel system and that the distortions are more severe for the outer sub-channels, both using EDC and MC-DBP. It is also found that the origin of EEPN depends on the relative position between the carrier phase recovery module and the EDC (or MC-DBP) module. Considering EEPN, diverse coding techniques and modulation formats have to be applied for optimizing different sub-channels in superchannel systems.

  12. Multi-channel, fiber-based seed pulse distribution system for femtosecond-level synchronized chirped pulse amplifiers

    Science.gov (United States)

    Horáček, Martin; Indra, Lukáš; Green, Jonathan T.; Naylon, Jack A.; Tykalewicz, Boguslaw; Novák, Jakub; Batysta, František; Mazanec, Tomáš; Horáček, Jakub; Antipenkov, Roman; Hubka, Zbyněk; Boge, Robert; Bakule, Pavel; Rus, Bedřich

    2017-01-01

    We report on the design and performance of a fiber-based, multi-channel laser amplifier seed pulse distribution system. The device is designed to condition and distribute low energy laser pulses from a mode-locked oscillator to multiple, highly synchronized, high energy amplifiers integrated into a laser beamline. Critical functions such as temporal pulse stretching well beyond 100 ps/nm, pulse picking, and fine control over the pulse delay up to 300 ps are all performed in fiber eliminating the need for bulky and expensive grating stretchers, Pockels cells, and delay lines. These functions are characterized and the system as a whole is demonstrated by seeding two high energy amplifiers in the laser beamline. The design of this system allows for complete computer control of all functions, including tuning of dispersion, and is entirely hands-free. The performance of this device and its subsystems will be relevant to those developing lasers where reliability, size, and cost are key concerns in addition to performance; this includes those developing large-scale laser systems similar to ours and also those developing table-top experiments and commercial systems.

  13. Optimizing a Multi-Channel ANC System for Broadband Noise Cancellation in a Telephone Kiosk Using Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Allahyar Montazeri

    2009-01-01

    Full Text Available The problem of optimizing an active noise control system for the implementation of a multi-channel ANC system with the aim of global reduction of broadband noise in a telephone kiosk is addressed in this paper. This optimization involves finding best locations for loudspeakers and microphones, and optimizing control signals. The problem of finding a proper size for control system, i.e. the number of loudspeakers and microphones involved in the control system is also investigated. The mean of acoustic potential energy in the enclosure in a frequency range of 50 Hz to 300 Hz is selected as a measure for optimization. Several genetic algorithms are proposed and compared to find the global minimum of this performance index. In order to have a better performance in reaching the global minimum, the parameters of these genetic algorithms are tuned, and the best genetic algorithm is selected among them. Numerical simulations of the acoustical potential energy and also sound pressure at the height where the head of a person may be located, confirms the optimality of the locations proposed by the genetic algorithm. Besides, the robustness of the optimized control system with respect to eventual changes in the location of primary and secondary loudspeakers and also microphones is shown with several simulations.

  14. Enhancement of the multi-channel continuous monitoring system through the use of Xenorhabdus luminescens lux fusions.

    Science.gov (United States)

    Lee, Jin Hyung; Mitchell, Robert J; Gu, Man Bock

    2004-10-15

    The enhancement of the multi-channel continuous toxicity monitoring system developed previously was studied. To achieve better and more stable results from the system, the use of thermo-lux fusion strains that express the luxCDABE genes from Xenorhabdus luminescens was evaluated. A total of six recombinant Escherichia coli strains with the promoters from three oxidative-stress responsive genes, i.e. the katG, sodA and pqi-5 genes, fused to either the lux genes from Vibrio fischeri or X. luminescens were characterized and their responses to different chemicals compared. It was found that the basal level bioluminescence (BL) from the thermo-lux fusion strains was always higher while that of the V. fischeri lux strains were always near or below the lower limit of detection of the system. For example, the katG::V. fischeri lux strain, DPD2511, gave no discernible response due to its low level expression while a fusion of the katG promoter with the X. luminescens lux operon was clearly responsive and capable of detecting hydrogen peroxide down to about 1 ppm. The use of the thermo-lux strains found them to be as sensitive as the V. fischeri lux strains while providing a brighter, more stable basal level bioluminescence, making the analysis and monitoring of water-borne toxicity more reliable.

  15. Design and performance of a fiber array coupled multi-channel photon counting, 3D imaging, airborne lidar system

    Science.gov (United States)

    Huang, Genghua; Shu, Rong; Hou, Libing; Li, Ming

    2014-06-01

    Photon counting lidar has an ultra-high sensitivity which can be hundreds even thousands of times higher than the linear detection lidar. It can significantly increase the system's capability of detection rang and imaging density, saving size and power consumings in airborne or space-borne applications. Based on Geiger-mode Si avalanche photodiodes (Si-APD), a prototype photon counting lidar which used 8 APDs coupled with a 1×8-pixel fiber array has been made in June, 2011. The experiments with static objects showed that the photon counting lidar could operate in strong solar background with 0.04 receiving photoelectrons on average. Limited by less counting times in moving platforms, the probability of detection and the 3D imaging density would be lower than that in static platforms. In this paper, a latest fiber array coupled multi-channel photon counting, 3D imaging, airborne lidar system is introduced. The correlation range receiver algorithm of photon counting 3D imaging is improved for airborne signal photon events extraction and noise filter. The 3D imaging experiments in the helicopter shows that the false alarm rate is less than 6×10-7, and the correct rate is better than 99.9% with 4 received photoelectrons and 0.7MHz system noise on average.

  16. Development and application of a multi-channel monitoring system for near real-time VOC measurement in a hazardous waste management facility.

    Science.gov (United States)

    Je, Chung-hwan; Stone, Richard; Oberg, Steven G

    2007-09-01

    This paper describes the development and application of a multi-channel monitoring system for recording, processing, and analyzing volatile organic compound (VOC) levels discharged to the atmosphere from a walk-in hood in a hazardous waste management facility. The monitoring system consists of an array of PID (photo ionization detector) sensors and a networked control program that provides operational schematic diagram, performs data analyses, and illustrates real-time graphical displays. Furthermore, the system records potential worker exposures, exhaust filtration efficiency and environmental release levels. Multi-channel continuous monitoring of VOCs is successfully implemented during chemical bulking operations. It is shown that a real-time monitoring system is effective for early warning detection of hazardous chemicals and for predicting the performance of adsorption filters used for VOC removal. In addition, a connected local weather visualization system supports efforts to minimize potential health and environmental impacts of VOC emissions to surrounding areas.

  17. Multi-channel SNSPD system with high detection efficiency at telecommunication wavelength

    CERN Document Server

    Miki, Shigehito; Fujiwara, Mikio; Sasaki, Masahide; Wang, Zhen

    2010-01-01

    We developed a four-channel superconducting nanowire single-photon detector system based on a Gifford-McMahon cryocooler. All channels showed a system detection efficiency (at a 100 Hz dark-count rate) higher than 16% at 1550 nm wavelength, and the best channel showed a system DE of 21% and 30% at 1550 nm and 1310 nm wavelength, respectively.

  18. Multi-Channel High-Tc SQUID Detection System for Metallic Contaminants

    Science.gov (United States)

    Kitamura, Yoshihiro; Hatsukade, Yoshimi; Tanaka, Saburo; Ohtani, Takeyoshi; Suzuki, Shuichi

    Finding ultra-small metallic contaminants is a big issue for manufacturers of lithium-ion batteries nowadays. Therefore, we have developed high-Tc SQUID systems for detection of such fine magnetic metallic contaminants. In this paper, we constructed an eight channel high-Tc SQUID gradiometer system for inspection of a sheet electrode of a lithium ion battery with width of about 70 mm. By this system, a small iron ball of about 30 μm in diameter was successfully detected. It is shown that this system has a detectable range of 70 mm in width. These results suggest that the system is a promising tool for the detection of the contaminants in lithium ion batteries.

  19. Investigation of creating possibilities of multi-channel optical system with discrete angular field

    Science.gov (United States)

    Repin, Vladislav A.; Gorbunova, Elena V.; Chertov, Aleksandr N.

    2016-04-01

    Often, in practice, there is a problem of large areas of space viewing in order to fix certain parameters of moving objects. A multichannel optical-electronic monitoring system with a discrete angular field (or, as they say, artificial compound eye system) is an interesting variant to solve this problem. Such systems can be used for the analysis of various parameters of the objects, as an example for positioning of the object in wide annular zone. Using these systems we can get a wide angular field up to the full sphere due to a combination of a large number of elementary light detecting channels (like compound eyes of insects) and have a gain in the useful signal due to overlapping angular fields of channels. Currently, multichannel optoelectronic systems with discrete angular field are described and studied less than other up-to-date monitoring devices. But existing analogues are presented by experimental samples, which demonstrate the relevance of the research and design of such devices. This work presents a brief review of monitoring system with discrete angular field and theoretical description of proposed prototype. Results of experimental studies of mentioned prototype are presented as well.

  20. Multi-Channel Magnetocardiogardiography System Based on Low-Tc SQUIDs in an Unshielded Environment

    Science.gov (United States)

    Kong, Xiangyan; Zhang, Shulin; Wang, Yongliang; Zeng, Jia; Xie, Xiaoming

    Magnetocardiography (MCG) using superconducting quantum interference devices (SQUIDs) is a new medical diagnostic tool measuring biomagnetic signals that are generated by the electrical activity of the human heart. This technique is completely passive, contactless, and it has an advantage in the early diagnosis of heart diseases. We developed the first unshielded four-channel MCG system based on low-Tc DC SQUIDs in China. Instead of using a costly magnetically shielded room, the environmental noise suppression was realized by using second-order gradiometers and three-axis reference magnetometer. The measured magnetic field resolution of the system is better than 1 pT, and multi-cycle human heart signals can be recorded directly. Also, with the infrared positioning system, 48 points data collection can be realized by moving the non-magnetic bed nine times.

  1. Development of digital flow control system for multi-channel variable-rate sprayers

    Science.gov (United States)

    Precision modulation of nozzle flow rates is a critical step for variable-rate spray applications in orchards and ornamental nurseries. An automatic flow rate control system activated with microprocessors and pulse width modulation (PWM) controlled solenoid valves was developed to control flow rates...

  2. Performance evaluation of multi-channel wireless mesh networks with embedded systems.

    Science.gov (United States)

    Lam, Jun Huy; Lee, Sang-Gon; Tan, Whye Kit

    2012-01-01

    Many commercial wireless mesh network (WMN) products are available in the marketplace with their own proprietary standards, but interoperability among the different vendors is not possible. Open source communities have their own WMN implementation in accordance with the IEEE 802.11s draft standard, Linux open80211s project and FreeBSD WMN implementation. While some studies have focused on the test bed of WMNs based on the open80211s project, none are based on the FreeBSD. In this paper, we built an embedded system using the FreeBSD WMN implementation that utilizes two channels and evaluated its performance. This implementation allows the legacy system to connect to the WMN independent of the type of platform and distributes the load between the two non-overlapping channels. One channel is used for the backhaul connection and the other one is used to connect to the stations to wireless mesh network. By using the power efficient 802.11 technology, this device can also be used as a gateway for the wireless sensor network (WSN).

  3. Energy and spectral efficiency analysis for selective ARQ multi-channel systems

    KAUST Repository

    Shafique, Taniya

    2017-07-31

    In this paper, we develop selective retransmission schemes for multiple-channel systems. The proposed schemes are selective automatic repeat request with fixed bandwidth (SARQ-FB), selective chase combining with fixed bandwidth (SCC-FB) and selective automatic repeat request with variable bandwidth (SARQ-VB). The main objective of the proposed schemes is to use the available power and bandwidth budget effectively along with the selective retransmission to deliver the required data successfully within a limited number of transmissions. To investigate the performance of each scheme, we first analyze the average spectral and energy efficiency and derive closed form expressions for each scheme. Then, we compare the EE and SE of each scheme through numerical results.

  4. Increasing the acquisition speed of a multi-channel guided wave system via simultaneous coded excitations

    Science.gov (United States)

    Hua, Jiadong; Michaels, Jennifer E.; Chen, Xin; Lin, Jing

    2017-02-01

    Many guided wave systems that are being evaluated for nondestructive evaluation or structural health monitoring utilize multiple transducers. Data are typically acquired by exciting each transducer in turn and recording received signals on the remaining transducers either simultaneously or separately. For either case, it can be very slow to acquire data because of the multiple transmission cycles combined with a slow repetition rate and extensive signal averaging. This long acquisition time brings another disadvantage by increasing the risk of environmental changes occurring during the complete acquisition process. For example, applied loads and temperature could change over the several seconds that are frequently required to acquire data. To increase the acquisition speed, it is proposed here to simultaneously trigger multiple transmitters, and each transmitter is driven with a unique, coded excitation. The simultaneously transmitted waves are captured by one or more receivers, and their responses are processed by dispersive matched filtering to separately extract the contribution from each transmitter. Results are shown for signals obtained from a spatially distribution array mounted on an aluminum plate.

  5. Fetal cardiac activity analysis during twin pregnancy using a multi-channel SQUID system

    Science.gov (United States)

    Costa Monteiro, E.; Schleussner, E.; Kausch, S.; Grimm, B.; Schneider, A.; Hall Barbosa, C.; Haueisen, J.

    2001-05-01

    The use of SQUID magnetometers for non-invasive in utero assessment of cardiac electrical disturbances has already been shown to be a valuable clinical tool. In this way, its applicability also for the complicated case of twin pregnancy, in which the proximity of the cardiac magnetic source of each fetus can hamper the individual analysis of cardiac electrical activity, is of clinical interest. In this paper, we present fetal magnetocardiography performed on a mother pregnant of twins with 26 weeks gestational age, measured inside a magnetically shielded room, by using two identical 31-channel low- Tc SQUID magnetometer systems. Each sensor array has been positioned over one of the fetuses, according to its heart position previously assessed with the aid of ultrasound measurements. The raw data is initially averaged in time and, afterwards, analyzed by means of time plots and isofield maps. The time recordings allow the study of the morphology of each fetus’ cardiac signal and the cardiac time intervals. The resultant equivalent dipole obtained from the isofield maps indicates the position and orientation of each fetus heart. The results agree with the ultrasound analysis performed immediately before the measurements and used to obtain the approximate location of the fetuses’ hearts. Since a distinct analysis of the cardiac electrical activity of each fetus could be achieved, the results indicate the potential of the fetal magnetocardiography in the individual antenatal diagnosis of each one of the fetuses of a twin pregnancy.

  6. Low noise multi-channel biopotential wireless data acquisition system for dry electrodes

    Science.gov (United States)

    Pandian, P. S.; Whitchurch, Ashwin K.; Abraham, Jose K.; Bhusan Baskey, Himanshu; Radhakrishnan, J. K.; Varadan, Vijay K.; Padaki, V. C.; Bhasker Rao, K. U.; Harbaugh, R. E.

    2008-03-01

    The bioelectrical potentials generated within the human body are the result of electrochemical activity in the excitable cells of the nervous, muscular or glandular tissues. The ionic potentials are measured using biopotential electrodes which convert ionic potentials to electronic potentials. The commonly monitored biopotential signals are Electrocardiogram (ECG), Electroencephalogram (EEG) and Electromyogram (EMG). The electrodes used to monitor biopotential signals are Ag-AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gels used in biopotential recordings dry out when used for longer durations and add noise to the signals and also prolonged use of gels cause irritations and rashes to skin. Also noises such as motion artifact and baseline wander are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry electrodes are used, where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The major drawback associated with the dry electrodes is the high skin-electrode impedance in the low frequency range between 0.1-120 Hz, which makes it difficult to acquire clean and noise free biopotential signals. The paper presents the design and development of biopotential data acquisition and processing system to acquire biopotential signals from dry electrodes. The electrode-skin-electrode- impedance (ESEI) measurements was carried out for the dry electrodes by impedance spectroscopy. The biopotential signals are processed using an instrumentation amplifier with high CMRR and high input impedance achieved by boot strapping the input terminals. The signals are band limited by means of a second order Butterworth band pass filters to eliminate noise. The processed biopotential signals are digitized

  7. Mixed Gl2/GH2 multi-channel multi-objective control synthesis for discrete time systems

    Institute of Scientific and Technical Information of China (English)

    颜文俊; 张森林

    2004-01-01

    This paper proposes a new approach for multi-objective robust control.The approach extends the standard generalized l2(Gl2)and generalized H2(GH2)conditions to a set of new linear matrix inequality(LMI)constraints based on a new stability condition.A technique for variable parameterization is introduced to the multi-objective control problem to preserve the linearity of the synthesis variables.Consequently,the multi-channel multi-objective mixed Gl2/GH2 control problem can be solved less conservatively using computationally tractable algorithms developed in the paper.

  8. An Intelligent Monitoring System on Multi-channel Temperature%一种智能型多功能校验仪

    Institute of Scientific and Technical Information of China (English)

    王成福; 唐金花; 陈偕雄

    2001-01-01

    This paper introduces a multi-channel temperature monitoring system which has high ratio of function to price and takes advantages of PLC. The system can process not less than 48 temperature channels without additional analog modules. The hardware constitution and software design of the system are chiefly stated.%介绍一种智能型多功能校验仪。它主要用于检定、校验便携式数字万用表,各种指针式万用表及直流0.2级、交流0.5级以下的表头,测试过程中数据自动处理,可以打印测试结果。

  9. Packed multi-channels for parallel chromatographic separations in microchips.

    Science.gov (United States)

    Nagy, Andrea; Gaspar, Attila

    2013-08-23

    Here we report on a simple method to fabricate microfluidic chip incorporating multi-channel systems packed by conventional chromatographic particles without the use of frits. The retaining effectivities of different bottlenecks created in the channels were studied. For the parallel multi-channel chromatographic separations several channel patterns were designed. The obtained multipackings were applied for parallel separations of dyes. The implementation of several chromatographic separation units in microscopic size makes possible faster and high throughput separations.

  10. CCD Detection System for Multi-channel Microfluidic Electrophoresis Chip%多通道微流控电泳芯片CCD检测系统

    Institute of Scientific and Technical Information of China (English)

    吕宏峰; 闫卫平; 朱杰英

    2012-01-01

    针对微流控电泳芯片检测系统微型化、集成化的要求,分析了传统电泳芯片检测系统的优势和不足,提出一种以FPGA芯片为控制器的CCD多通道微流控电泳芯片检测系统.利用FPGA/NiosⅡ嵌入式系统解决方案,以EP2C8Q208芯片为核心,设计了CCD驱动及外围硬件电路.通过上位机软件进行数据处理,实现了荧光图谱的同步显示.实验结果表明:该系统能同时检测多通道微流控电泳芯片中各通道不同的荧光信号强度,具有较高的灵敏度和信噪比,对罗丹明B样品的最低检测浓度为1.0×10-6mol/L,能够满足多通道微流控电泳芯片检测的要求.%Based on the requirement with detection system for microfluidic electrophoresis chip in terms of miniaturization, integration , the traditional equipment advantage and the shortage was analyzed. A CCD detection system for multi-channel microfluidic electrophoresis chip used FPGA as the main logic controller was proposed. FPGA/Nios Ⅱ embedded system was adopted into the project which designed the CCD driving and other periphery circuit with the EP2C8Q208 chip as its core. The data was transferred to the PC. Then the fluorescence spectrum was shown by the software. The result indicated that the system can detect the different fluorescence intensity in the micirofluidic chip at the same time. The minimum detecting limit is 1.0 × 10-6 mol/L (Rhodamine B). This detecting system has several characteristics such as high signal-noise ratio and high sensitivity, which can meet the demand of detection of the multi-channel micirofluidic electrophoresis chip.

  11. The Implement of Multi-Channel Noise Test System in Anechoic Chamber%消声室多通道噪声测试系统实现

    Institute of Scientific and Technical Information of China (English)

    刘维嘉

    2016-01-01

    This paper introduces the multi-channel noise test system based on virtual instrument technology. This test system uses microphones,preamplifier and sound vibration data acquisition hardware.The test sys-tem is realized by LabVIEW;it can test the sound pressure level and sound power level for machinery and oth-er machinery.And the test system with high performance,high precision,etc.,greatly improving the efficiency while significantly reducing the cost of test.%该文介绍了基于虚拟仪器技术的多通道噪声测试系统。该系统硬件采用了传声器、预放及声音振动数据采集卡,通过LabVIEW编写测试系统,实现对机器机械等噪声源的声压级和声功率级测试。该测试系统具有高性能、高精度等优点,在提高效率的同时降低了测试成本。

  12. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  13. Multi-Channel Electroencephalogram (EEG Signal Acquisition and its Effective Channel selection with De-noising Using AWICA for Biometric System

    Directory of Open Access Journals (Sweden)

    B.Sabarigiri

    2014-05-01

    Full Text Available the embedding of low cost electroencephalogram (EEG sensors in wireless headsets gives improved authentication based on their brain wave signals has become a practical opportunity. In this paper signal acquisition along with effective multi-channel selection from a specific area of the brain and denoising using AWICA methods are proposed for EEG based personal identification. At this point, to develop identification system the steps are as follows. (i the high-quality device with the least numbers of channels are essential for the EEG signal acquisition and Selecting the equipment and verdict the best portions on the scalp is the primary step. (ii Scrutiny of the acquired EEG signals and de-noising from EMG, ECG, EOG Signals and power line artifacts using AWICA (iii Obtain the features from the Enhanced EEG signals by Wavelet Transform (WT and LS-SVM Classification in the MATLAB Environment. Based on the outcome, there is possibility for implementation of an EEG based Practical biometric system.

  14. Imaging observations of nighttime mid-latitude F-region field-aligned irregularities by an MU radar ultra-multi-channel system

    Directory of Open Access Journals (Sweden)

    S. Saito

    2008-08-01

    Full Text Available Mid-latitude F-region field-aligned irregularities (FAIs were studied by using the middle-and-upper atmosphere (MU radar ultra-multi-channel system with the radar imaging technique. On 12 June 2006, F-region FAI echoes with a period of about one hour were observed intermittently. These echoes were found to be embedded in medium-scale traveling ionospheric disturbances (MSTIDs observed as variations of total electron content (TEC. The echoes drifting away from (toward the radar were observed in the depletion (enhancement phase of the MSTID. The Doppler velocity of the echoes is consistent with the range rates in the the range-time-intensity (RTI maps. Fine scale structures with a spatial scale of 10 km or less were found by the radar imaging analysis. Those structures with positive Doppler velocities (moving away from the radar appeared to drift north- (up- westward, and those with negative Doppler velocities south- (down- eastward approximately along the wavefronts of the MSTID. FAIs with positive Doppler velocities filling TEC depletion regions were observed.

  15. Multi-Channel Auto-Dilution System for Remote Continuous Monitoring of High Soil-CO2 Fluxes

    Energy Technology Data Exchange (ETDEWEB)

    Amonette, James E.; Barr, Jonathan L.

    2009-04-23

    Geological sequestration has the potential capacity and longevity to significantly decrease the amount of anthropogenic CO2 introduced into the atmosphere by combustion of fossil fuels such as coal. Effective sequestration, however, requires the ability to verify the integrity of the reservoir and ensure that potential leakage rates are kept to a minimum. Moreover, understanding the pathways by which CO2 migrates to the surface is critical to assessing the risks and developing remediation approaches. Field experiments, such as those conducted at the Zero Emissions Research and Technology (ZERT) project test site in Bozeman, Montana, require a flexible CO2 monitoring system that can accurately and continuously measure soil-surface CO2 fluxes for multiple sampling points at concentrations ranging from background levels to several tens of percent. To meet this need, PNNL is developing a multi-port battery-operated system capable of both spatial and temporal monitoring of CO2 at concentrations from ambient to at least 150,000 ppmv. This report describes the system components (sampling chambers, measurement and control system, and power supply) and the results of a field test at the ZERT site during the late summer and fall of 2008. While the system performed well overall during the field test, several improvements to the system are suggested for implementation in FY2009.

  16. 基于 FPGA+USB2.O多通道数据采集系统设计%Design of Multi-channel Data Acquisition System Based on FPGA and USB2.0

    Institute of Scientific and Technical Information of China (English)

    程海狮; 黄玉清

    2011-01-01

    针对传统数据采集系统中主控制器升级慢和传输芯片速率低等弊端,利用FPGA内嵌FIR滤波器抗干扰、现场可编程性、容易升级与更新以及USB接口通用性好、传输速率快的优点,设计了基于FPGA+USB2.0多通道数据采集系统,能够完成4路最大采样频率150 kHz、精度为12位的数据采集和传输,实现了高精度数据采集.%In the traditional data acquisition system design, primary controller is hard to update and the transmission speed of transmission chip is low. This peper has designed a multi-channel data acquisition system based on FPCA and USB2. 0. The system achieves acquiring 4 - route data acquisition with the maximal frequency of 150 KHz and the precision of 12 bits. The system has desgined multi-channel FIR filter. This approach can achieve real-time filter and eliminate the interference. The system is modular design, high stability, can be widely used for multi-channel data acquisition.

  17. Development and Test of a High Performance Multi Channel Readout System on a Chip with Application in PET/MR

    OpenAIRE

    2014-01-01

    The availability of new, compact, magnetic field tolerant sensors suitable for PET has opened the opportunity to build highly integrated PET scanners that can be included in commercial MR scanners. This combination has long been expected to have big advantages over existing systems combining PET and CT. This thesis describes my work towards building a highly integrated readout ASIC for application in PET/MR within the framework of the HYPERImage and SUBLIMA projects. It also gives a brief ...

  18. Pyroelectric IRFPA mosaic image acquisition system with multi channels%多通道热释电 IRFPA 图像拼接采集系统

    Institute of Scientific and Technical Information of China (English)

    程瑶

    2014-01-01

    为了实现分辨率高的大规模热释电IRFPA 探测器,设计了多路通道并行输出的读出电路。针对多路输出的热释电IRFPA探测器,依据热释电探测的时序要求,设计了图像拼接采集系统。利用外部驱动信号控制采集卡的触发及采样时钟,由斩波器同步信号判断热释电探测器的亮场及暗场信号。构造PC-DA Q虚拟仪器系统对多通道输出的热释电型IRFPA进行多路并行图像采集,并对每路图像信号进行亮、暗场判断后进行差分处理,通过软件拼接处理成一副完整的图像,最终在软件平台上显示。对实验室研制的160列×120行双通道读出及320列×120行四通道读出的热释电读出电路进行了图像采集实验,对于同样阵列大小的单通道读出探测器,双通道结构读出速度提高了1倍,四通道结构读出速度提高了3倍。通过采集成像实验验证了系统的可行性。%In order to achieve large-scale pyroelectric infrared focal plane array (IRFPA ) detec-tor with high resolution ,the readout circuit with multi-channel parallel output was designed . Based on the pyroelectric IRFPA detector of multiple-output and the pyroelectric detecting tim-ing requirements ,the system of mosaic imaging acquisition was designed .The external driving signals were used to control the trigger and sampling clock of acquisition card ,and a chopper synchronizing signal was used to judge the bright field and dark field signal of the pyroelectric detector .The system was constructed with PC-DAQ virtual instrument system to acquire multi-channel parallel image ,judge the bright and dark field for differential processing on each channel ,and display a whole image after mosaic processing on software platform .The experi-mental image acquisition of the pyroelectric readout circuit with 160 × 120 two-channels read-out and 320 × 120 four-channels readout were taken and the output signal waveform and image were

  19. Connectivity of Multi-Channel Fluvial Systems: A Comparison of Topology Metrics for Braided Rivers and Delta Networks

    Science.gov (United States)

    Tejedor, A.; Marra, W. A.; Addink, E. A.; Foufoula-Georgiou, E.; Kleinhans, M. G.

    2016-12-01

    Advancing quantitative understanding of the structure and dynamics of complex networks has transformed research in many fields as diverse as protein interactions in a cell to page connectivity in the World Wide Web and relationships in human societies. However, Geosciences have not benefited much from this new conceptual framework, although connectivity is at the center of many processes in hydro-geomorphology. One of the first efforts in this direction was the seminal work of Smart and Moruzzi (1971), proposing the use of graph theory for studying the intricate structure of delta channel networks. In recent years, this preliminary work has precipitated in a body of research that examines the connectivity of multiple-channel fluvial systems, such as delta networks and braided rivers. In this work, we compare two approaches recently introduced in the literature: (1) Marra et al. (2014) utilized network centrality measures to identify important channels in a braided section of the Jamuna River, and used the changes of bifurcations within the network over time to explain the overall river evolution; and (2) Tejedor et al. (2015a,b) developed a set of metrics to characterize the complexity of deltaic channel networks, as well as defined a vulnerability index that quantifies the relative change of sediment and water delivery to the shoreline outlets in response to upstream perturbations. Here we present a comparative analysis of metrics of centrality and vulnerability applied to both braided and deltaic channel networks to depict critical channels in those systems, i.e., channels where a change would contribute more substantially to overall system changes, and to understand what attributes of interest in a channel network are most succinctly depicted in what metrics. Marra, W. A., Kleinhans, M. G., & Addink, E. A. (2014). Earth Surface Processes and Landforms, doi:10.1002/esp.3482Smart, J. S., and V. L. Moruzzi (1971), Quantitative properties of delta channel networks

  20. Multi-channel blind deconvolution algorithm for multiple-input multiple-output DS/CDMA system

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Direct sequence spread spectrum transmission can be realized at low SNR,and has low probability of detection.It is aly problem how to obtain the original users'signal in a non-cooperative context.In practicality,the DS/CDMA sources received are linear convolute mixing.A more complex multichannel blind deconvolution MBD algorithm is required to achieve better source separation.An improved MBD algorithm for separating linear convolved mixtures of signals in CDMA system is proposed.This algorithm is based on minimizing the average squared cross-output-channel-correlation.The mixture coefficients are totally unknown.while some knowledge about temporal model exists.Results show that the proposed algorithm Can bring about the exactness and low computational complexity.

  1. Surface morphology and surface energy of anode materials influence power outputs in a multi-channel mediatorless bio-photovoltaic (BPV) system.

    Science.gov (United States)

    Bombelli, Paolo; Zarrouati, Marie; Thorne, Rebecca J; Schneider, Kenneth; Rowden, Stephen J L; Ali, Akin; Yunus, Kamran; Cameron, Petra J; Fisher, Adrian C; Ian Wilson, D; Howe, Christopher J; McCormick, Alistair J

    2012-09-21

    Bio-photovoltaic cells (BPVs) are a new photo-bio-electrochemical technology for harnessing solar energy using the photosynthetic activity of autotrophic organisms. Currently power outputs from BPVs are generally low and suffer from low efficiencies. However, a better understanding of the electrochemical interactions between the microbes and conductive materials will be likely to lead to increased power yields. In the current study, the fresh-water, filamentous cyanobacterium Pseudanabaena limnetica (also known as Oscillatoria limnetica) was investigated for exoelectrogenic activity. Biofilms of P. limnetica showed a significant photo response during light-dark cycling in BPVs under mediatorless conditions. A multi-channel BPV device was developed to compare quantitatively the performance of photosynthetic biofilms of this species using a variety of different anodic conductive materials: indium tin oxide-coated polyethylene terephthalate (ITO), stainless steel (SS), glass coated with a conductive polymer (PANI), and carbon paper (CP). Although biofilm growth rates were generally comparable on all materials tested, the amplitude of the photo response and achievable maximum power outputs were significantly different. ITO and SS demonstrated the largest photo responses, whereas CP showed the lowest power outputs under both light and dark conditions. Furthermore, differences in the ratios of light : dark power outputs indicated that the electrochemical interactions between photosynthetic microbes and the anode may differ under light and dark conditions depending on the anodic material used. Comparisons between BPV performances and material characteristics revealed that surface roughness and surface energy, particularly the ratio of non-polar to polar interactions (the CQ ratio), may be more important than available surface area in determining biocompatibility and maximum power outputs in microbial electrochemical systems. Notably, CP was readily outperformed by all

  2. Multi-channel photon counting three-dimensional imaging laser radar system using fiber array coupled Geiger-mode avalanche photodiode

    Science.gov (United States)

    Shu, Rong; Huang, Genghua; Hou, Libing; He, Zhiping; Hu, Yihua

    2012-09-01

    Photon counting laser radar is the most sensitive and efficiency detection method of direct-detection laser radar. With the use of Geiger-mode avalanche photodiode (APD) or other single photon detectors, every laser photon could be sufficiently used for ranging and three-dimensional imaging. The average energy of received laser signal could be as low as a single photon, or even less than one. This feature of photon counting laser radar enables ranging under conditions of long range, low laser pulse energy, and multi-pixel detection, while receiver size, mass, power, and complexity of laser radar are reduced. In this paper, a latest multi-channel photon counting 3D imaging laser radar system using fiber array coupled Geiger-mode avalanche photodiode (APD) is introduced. Detection model based on Poisson statistics of a photon counting laser radar is discussed. A laser radar system, working under daylight condition with ultra-low signal level (less than single photon per pulse), has been designed and analyzed with the detection model and photon counting three-dimensional imaging theory. A passively Q-switched microchip laser is used to transmit short sub-nanosecond laser pulses at 532nm. The output laser is divided into 1×8 laser spots, which correspond to 8 Geiger-mode avalanche photodiodes coupled by a 1×8-pixel fiber array. A FPGA based time-to-digital converter (TDC), which is designed by delay line interpolation technology, is used for multi-hit signal acquisition. The algorithm of photon counting three-dimensional imaging is developed for signal photon events extraction and noise filter. Three-dimensional images under daylight conditions were acquired and analyzed. The results show that system could operate at strong solar background. The ranging accuracy of the system is 6.3cm (σ) while received laser pulse signal level is only 0.04 photoelectrons on average. The advantages and feasibility of photon counting laser radar working at daylight have been

  3. CAPACITY EVALUATION OF MULTI-CHANNEL WIRELESS AD HOC NETWORKS

    Institute of Scientific and Technical Information of China (English)

    Li Jiandong; Zygmunt J. Haas; Min Sheng

    2003-01-01

    In this paper, the capacity of multi-channel, multi-hop ad hoc network is evaluated.In particular, the performance of multi-hop ad hoc network with single channel IEEE 802.11MAC utilizing different topologies is shown. Also the scaling laws of throughputs for large-scale ad hoc networks and the theoretical guaranteed throughput bounds for multi-channel gridtopology systems are proposed. The results presented in this work will help researchers to choosethe proper parameter settings in evaluation of protocols for multi-hop ad hoc networks.

  4. Perfect Multi-Channel Flat Reflectors

    CERN Document Server

    Asadchy, V S; Elsakka, A; Albooyeh, M; Tretyakov, S A

    2016-01-01

    Recent advances in engineered gradient metasurfaces have enabled unprecedented opportunities for light manipulation using optically thin sheets, such as anomalous refraction, reflection, or focusing of an incident beam. Here we introduce a concept of multi-channel functional metasurfaces, which are able to control incoming and outgoing waves in a number of propagation directions or polarization states simultaneously and independently. In particular, we reveal a possibility to create perfect multi-channel reflectors. Under the assumption of reciprocity and energy conservation, we find that there exist three fundamental classes of multi-channel mirrors. Together they form a basis of all possible reflection functionalities achievable with flat periodically modulated reflectors. To demonstrate the potential of the introduced concept, we design and experimentally test one of the basis multi-channel reflectors, confirming the desired multi-channel response. Furthermore, by extending the concept to reflectors suppor...

  5. NVST多通道高分辨观测系统软件设计%NVST Multi-Channel High-Resolution Imaging System

    Institute of Scientific and Technical Information of China (English)

    陈宇超; 金振宇; 杨磊

    2016-01-01

    1m太阳望远镜多通道高分辨成像系统是望远镜的重要终端设备之一, 目前由Hα通道(线心656. 283 nm)和TiO通道( 705. 8 nm)构成. 主要介绍了多通道高分辨观测系统软件的设计. 观测系统在功能上主要实现了Hα通道多波长点扫描观测模式, TiO通道多时间分辨率观测模式, 以及为满足多通道发展的需求, 如常规观测通道的增加以及探测器的更换等, 在系统架构上采用了松耦合的分布式分层结构.%The New Vacuum Solar Telescope is an 1-meter, ground-based telescope which offers the unparalleled performance to solar observations. One of the important instruments in the NVST is the multi-channel high-resolution imaging system, and in the system five main work wave length ranges, including Hα, TiO-band, G-band, Ca II (854. 2nm) and He I (1083. 0nm) are covered. Up to now, Hα and TiO-band channels are being used. The Hα channel is an arrow-band imaging system, equipped with a tunable Lyot filter. The interpretation of the narrow-band filtergram is difficult due to the crosstalk between the brightness and the Dopplershift modulation, therefore the observational system is required to perform the multi-offband observation in Hαchannel to obtain a scanned profile in order to get meaningful physical information. The TiO-band is abroad-band imaging system and uses a high-cadence CMOS. To achieve much higher cadence for some specific observations, it should support to decrease the FOV to increase the acquisition speed of the camera. However, the software provided by the camera manufacturedis failed to meet the observation need so that a new observational software system is constructed to satisfy the different observational needs in two channels. Taking the factors into account that another three channel will soon be added and high-cadence cameras will come into uses, the software architecture designed for NVST acquisition system should provide the scalability and the

  6. Relationship between the prefrontal function and the severity of the emotional symptoms during a verbal fluency task in patients with major depressive disorder: a multi-channel NIRS study.

    Science.gov (United States)

    Liu, Xiaomin; Sun, Gaoxiang; Zhang, Xiaoqian; Xu, Bo; Shen, Chenyu; Shi, Lujie; Ma, Xiangyun; Ren, Xiajin; Feng, Kun; Liu, Pozi

    2014-10-03

    Multi-channel near-infrared spectroscopy (NIRS) is a noninvasive and low-cost functional neuroimaging technique in psychiatric research, and it has been wildly used for detecting the spatiotemporal characteristics of brain activity. In order to evaluate the clinical value of NIRS data in the assistant diagnosis of major depressive disorder (MDD), prefrontal cortex (PFC) hemoglobin concentration exchange of 30 MDD patients combined with anxious and obsessive-compulsive symptom was detected by NIRS under voice fluency task (VFT), then the relationship between the severity of depressive, anxious and obsessive-compulsive symptom assessed by Hamilton Rating Scale for Depression (HAMD), Hamilton Anxiety Rating Scale (HAMA) and Yale-Brown Obsessive Compulsive Scale (Y-BOCS) with NIRS data in PFC was analyzed. Hypoactivation in lateral and lower PFC of MDD patients was confirmed in this study. Furthermore, Spearman correlation found that oxy-hemoglobin concentration ([oxy-Hb]) exchange in right-lateral PFC was associated with the severity of anxiety, while bilateral PFC and antero-medial PFC were associated with severity of depression. Meanwhile, no statistical correlation was observed on the severity of obsessive-compulsive symptom. The results prompted that MDD patients with anxiety and obsession-compulsion symptom showed a PFC hypoactivation state in NIRS. Furthermore, the function of right-lateral PFC was associated with anxiety symptom, while bilateral PFC and antero-medial PFC were associated with depression symptom. Different from depression and anxiety, obsession-compulsion may have a different biological character in PFC function.

  7. Canonical framework for multi-channel SAR-GMTI

    Institute of Scientific and Technical Information of China (English)

    Liu Congfeng; Liao Guisheng

    2008-01-01

    Synthetic aperture radar (SAR) systems have become an important tool for fine-resolution mapping and other remote sensing operations.The multi-channel SAR ground moving-target indication (GMTI) must process its data to produce not only the image of surveillance area but also the information of the ground moving-targets.The topic of moving-target detection in clutter has been extensively studied,and there are many methods that are used to detect moving targets,such as displaced phase center antenna (DPCA) method,along-track interfero-metric (ATI) phase,space-time adaptive processing (STAP),or some other metrics.A canonical framework is proposed that encompasses all the multi-channel SAR-GMT methods,namely,DPCA and ATI.The statistical test metric for multi-channel SAR-GMTI is established in a simple form,via the definition of the complex central Wishart distribution,to deduce the statistics of the test metric,and the probability distribution of the test metric for multichannel SAR-GMTI has the complex central Wishart distribution of 1×1 case,namely the x2 distribution.The theory foundation offers the possibility to construct the united multi-channel SAR-GMTI detector,and derives the constant false alarm rate (CFAR) detector tests for separating moving targets from clutter.

  8. Filterbank implementation for multi-channel sampling in fractional Fourier domain

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Reconstruction of a continuous time signal from its periodic nonuniform samples and multi-channel samples is fundamental for multi-channel parallel A/D and MIMO systems. In this paper,with a filterbank interpretation of sampling schemes,the efficient interpolation and reconstruction methods for periodic nonuniform sampling and multi-channel sampling in the fractional Fourier domain are presented. Firstly,the interpolation and sampling identities in the fractional Fourier domain are derived by the properties of the fractional Fourier transform. Then,the particularly efficient filterbank implementations for the periodic nonuniform sampling and the multi-channel sampling in the fractional Fourier domain are introduced. At last,the relationship between the multi-channel sampling and the filterbank in the fractional Fourier domain is investigated,which shows that any perfect reconstruction filterbank can lead to new sampling and reconstruction strategies.

  9. Filterbank implementation for multi-channel sampling in fractional Fourier domain

    Institute of Scientific and Technical Information of China (English)

    ZHANG Feng; TAO Ran; WANG Yue

    2009-01-01

    Reconstruction of a continuous time signal from its periodic nonuniform samples and multi-channel samples is fundamental for multi-channel parallel A/D and MIMO systems. In this paper, with a filter-bank interpretation of sampling schemes, the efficient interpolation and reconstruction methods for periodic nonuniform sampling and multi-channel sampling in the fractional Fourier domain are pre-sented. Firstly, the interpolation and sampling identities in the fractional Fourier domain are derived by the properties of the fractional Fourier transform. Then, the particularly efficient filterbank implementa-tions for the periodic nonuniform sampling and the multi-channel sampling in the fractional Fourier domain are introduced. At last, the relationship between the multi-channel sampling and the filterbank in the fractional Fourier domain is investigated, which shows that any perfect reconstruction filterbank can lead to new sampling and reconstruction strategies.

  10. The multi-viewing, multi-channel, multi-polarisation imager on board the future EUMETSAT Polar System - Second Generation and its application for the aerosol retrieval

    Science.gov (United States)

    Kokhanovsky, Alexander; Munro, Rose; Lang, Ruediger; Lindstrot, Rasmus; Huckle, Roger; Marbach, Thierry; Poli, Gabriele

    2017-04-01

    Atmospheric aerosol is a global phenomenon. Due to the small size of aerosol particles (typically, 0.1 - 10 micrometers) they are rarely observed by the naked eye. Nevertheless aerosol particles are present in atmospheric air in variable numbers (typically, 100-1000 particles per cubic centimeter of atmospheric air). The particles have different chemical composition, origin, shapes, and internal structure (e.g., dust particles covered by ice, etc.). They influence human health, air quality, climate, downwelling and upwelling radiation, clouds, and precipitation. It is therefore important to monitor aerosol properties on a global scale. Global scale information can only be provided by satellite observations and algorithms for the production of satellite-based aerosol products have been in use already for more than 40 years. In this work we present an update on the recently developed operational EUMETSAT aerosol retrieval algorithm for the Multi-viewing, multi-channel, multi-polarisation Imager (3MI) which will fly on board the future EUMETSAT Polar System Second Generation (EPS-SG), planned for launch in the 2021 timeframe. The 3MI is a two - dimensional push - broom radiometer dedicated to aerosol and cloud characterization for climate monitoring, air quality forecasting and numerical weather prediction with heritage from the POLDER instrument. The first three components of the Stokes vector of the reflected light (I, Q, and U) will be measured at 9 channels in the spectral range from 410 to 2130nm for up to 14 observation directions. Intensity measurements only will be performed at 763, 765, and 910nm. This enables the determination of the degree of linear polarization of reflected light and also the direction of the oscillations of the electric vector in the light beam. The 3MI design consists of a filter and polariser wheel rotating in front of the detectors. For design purposes the spectral channels have been split into VNIR and SWIR filters and polarisers with

  11. Real-time multi-channels infrared image acquisition system based on FPGA%基于FPGA的多通道红外图像实时采集系统

    Institute of Scientific and Technical Information of China (English)

    李燕; 汤心溢; 葛军; 张浩钧

    2012-01-01

    不同于传统的单通道采集系统,RMCIIA拥有3个独立的数据通道,这些数据通道可以匹配不同数据形式和数据速率的红外探测器,并且根据不同的数据采集需求,FPGA中功能模块的组成结构可以进行重构.RMCIIA还运用新一代的高速总线—PCI Express总线技术,对3个独立通道的大量图像数据进行高速数据传输,并通过实行“循环优先级”的VC仲裁策略进行流量控制和多通道调度,从而为进一步的多波段红外图像处理和图像融合算法提供实时的、同时的多通道数据流.首先详细描述RMCIlA的系统结构和FPGA内算法功能模块,然后对多通道数据采集所面临的新问题提出设计的解决方案,最后由实验测定系统的传输速率,并且与传统的图像采集系统进行对比.总之,RMCIIA 实现了一个统一的多通道红外图像的实时采集系统.%Compared with the traditional imaging system with limited data rate and only one data channel, a real-time multi-channels infrared image acquisition (RMCIIA) system based on FPGA was proposed. RMCIIA has three data channels, each of which can connect up with detectors' interface in different data format and various data rate. And its FPGA architecture is able to be reconfigured for the diverse demands of data collection. RMCIIA also set up a new generation of high-speed bus-PCI Express bus, for rapidly transferring massive image data of three independent channels in high speed, and the flow control and multi-channels dispatch algorithms are applied by implementing "round robin priority arbitration" mechanism among VCs, so as to supply real-time and simultaneous multi-channels data flows for the schemes of multi-bands infrared image processing and image fusion. Firstly, the RMCIIA's system structure and the design of algorithms function modules on FPGA were described in detail. Then, the design solutions for the new problems with which multi-channels data acquisition system

  12. Multi-channel atomic magnetometer for magnetoencephalography: a configuration study.

    Science.gov (United States)

    Kim, Kiwoong; Begus, Samo; Xia, Hui; Lee, Seung-Kyun; Jazbinsek, Vojko; Trontelj, Zvonko; Romalis, Michael V

    2014-04-01

    Atomic magnetometers are emerging as an alternative to SQUID magnetometers for detection of biological magnetic fields. They have been used to measure both the magnetocardiography (MCG) and magnetoencephalography (MEG) signals. One of the virtues of the atomic magnetometers is their ability to operate as a multi-channel detector while using many common elements. Here we study two configurations of such a multi-channel atomic magnetometer optimized for MEG detection. We describe measurements of auditory evoked fields (AEF) from a human brain as well as localization of dipolar phantoms and auditory evoked fields. A clear N100m peak in AEF was observed with a signal-to-noise ratio of higher than 10 after averaging of 250 stimuli. Currently the intrinsic magnetic noise level is 4fTHz(-1/2) at 10Hz. We compare the performance of the two systems in regards to current source localization and discuss future development of atomic MEG systems.

  13. Acquisition, processing and interpretation of high-resolution seismic data using a small-scale multi-channel system: an example from the Korea Strait inner shelf, south-east Korea

    Science.gov (United States)

    Yoo, Dong-Geun; Koo, Nam-Hyung; Lee, Ho-Young; Kim, Byoung-Yeop; Kim, Young-Jun; Cheong, Snons

    2016-10-01

    A high-resolution seismic survey was designed to improve the quality of seismic data and study the evolution of inner shelf deposits off the southern coast of Korea. A 0.5 L air gun and 6- or 8-channel streamer cable with a 5 m group interval were used as a seismic source and receiver system, respectively. Data recording was digitally performed at a shot interval of 2 s and a sample interval of 0.1 ms using a personal computer (PC)-based recording system with an analogue to digital (A/D) converter. In the data processing, deconvolution and static corrections were very effective for improving the data resolution. The data resolution and signal-to-noise (S/N) ratio were improved by using multi-channel digital seismic systems as opposed to a single-channel analogue streamer. The results show that a small-scale multi-channel seismic system is an effective way to investigate late Quaternary deposits. Seismic stratigraphic analysis of the high-resolution seismic profiles revealed that inner shelf deposits, up to 30 m thick, consist of three sedimentary units, which comprise transgressive and highstand systems tracts deposited after the last glacial period. The transgressive systems tract includes two units (I and II) separated by a ravinement surface (RS). The lower Unit I, lying below the RS, consists of estuarine sediments left behind by shoreface erosion during transgression, and represents a paralic component. The upper Unit II, including two sub-units (IIa and IIb), lies above the RS and consists of sand produced by shoreface erosion during landward transgression, which corresponds to a marine component. The uppermost Unit III lies above the maximum flooding surface and consists of thick mud clinoforms of the modern Nakdong and Seomjin subaqueous deltas. This unit likely formed during the recent sea level highstand and represents the highstand systems tract.

  14. A Novel Multi-Channel Dispersion Slope Compensator Using Sampled FBG

    Institute of Scientific and Technical Information of China (English)

    J.; J.; Pan; Claire; Gu; Albert; Li

    2003-01-01

    A novel dispersion slope compensator is proposed and fabricated using a sampled fiber grating. The dispersion slope of this compensator is demonstrated to match that of Coming LS fiber for a multi-channel 50GHz WDM system.

  15. Design of Multi-channel Temperature Data Acquisition System Based on RS-485 Bus%一种基于RS-485总线的多路温度数据采集系统设计

    Institute of Scientific and Technical Information of China (English)

    吴林; 仲崇权; 杨素英; 牛德芳

    2001-01-01

    介绍一种基于RS-485总线的温度数据采集系统,应用于混凝土施工控制中。数据采集模块挂接在RS-485总线上构成RS-485总线网络,PC机与其进行数据通信。系统实现了对工业现场多路温度数据的采集、管理、显示与打印等功能。软件设计采用面向对象分析设计技术——Booch方法设计了项目类、图形类、工具类和数据类等,使系统模块化好,通用性强。%A multi-channel temperature data acquisition system has beenintroduced for the control of concrete construction.The data acquisition modules are connected on the RS-485 bus to form a RS-485 network,and data communication between PC and the modules is presented.The system implements the acquisition,management,displaying and printing of the multi-channel temperature data on the industry site.The item class,graphics class,tool class and data class have been designed using object-oriented analysis and design technique —— Booch method,so that the system has better modularity and universality.

  16. 用于X射线传感器的多通道微弱电流采集系统%Multi-channel Weak Current Acquisition System for X-ray Sensor

    Institute of Scientific and Technical Information of China (English)

    许超群; 孙颖; 朱大中; 韩雁

    2013-01-01

    在X射线传感器中,为了满足对集成片上闪烁层的6×6光电二极管阵列在脉冲型X射线激发下的光电流值的快速读出要求,提出了一种36通道微弱电流的快速采集系统的设计.系统主要包括低漏电流多路选择器、高精度电流镜和微控制器,在微控制器控制下,系统逐个读出36通道的微弱电流,经过A/D转换后采集值送到PC机显示.实验结果表明,该系统的采集精度可达1 nA,满足X射线传感器的多通道微弱电流的快速采集要求.%To rapidly acquire photocurrents of 6 × 6 photodiode arrays on scintillation layer of integrated chip which are excited by pulsed X-ray in X-ray senor,a multi-channel weak current rapid acquisition system is proposed.The system consists of low leak current multiplexer,high accuracy current mirror and microcontroller.It reads weak current values of the 36 channels sequentially under the control of microcontroller,and the data are sent to PC for display after A/D conversion.The experimental results show the system has the accuracy of 1 nA,meeting the requirement of rapid acquisition of multi-channel weak current for X-ray sensor.

  17. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  18. 基于Vega Prime的多通道三维仿真系统的实现%The implementation of multi-channel three-dimensional simulation system based on vega prime

    Institute of Scientific and Technical Information of China (English)

    赵必厦; 冯开平; 罗立宏

    2012-01-01

    The software system of 360 Degree Virtual Experience Zone, which was presented in Guangzhou Case Pavilion of Expo 2010 Shanghai China, is taken as a prototype in order to describe the implementation of multi-channel three-dimensional simulation system based on Vega Prime. First, the system is outlined with the description of the implementation principle and development process, and then the implementation of system is discussed with emphasis on the three main steps which are three-dimensional modeling, simulation system building and scene editing, demonstration effect and technical points in the stand-alone presentation are presented with the comparison of the new system and the old one.%论文以2010年上海世博会广州案例馆360度内环幕虚拟体验区的软件系统为原型,叙述了基于Vega Prime的多通道三维仿真系统的实现.首先对系统进行概述,描述了实现原理及开发流程,然后对系统实现展开讨论,重点叙述了三维建模、构建仿真系统、场景编辑3个主要的步骤,给出单机演示的技术要点及演示效果,并把新旧系统做了对比.

  19. Where does all the water go? Partitioning water transmission losses in a data-sparse, multi-channel and low-gradient dryland river system using modelling and remote sensing

    Science.gov (United States)

    Jarihani, Abdollah A.; Larsen, Joshua R.; Callow, John N.; McVicar, Tim R.; Johansen, Kasper

    2015-10-01

    Drylands cover approximately one-third of the Earth's surface, are home to nearly 40% of the Earth's population and are characterised by limited water resources and ephemeral river systems with an extremely variable flow regime and high transmission losses. These losses include actual evaporation, infiltration to the soil and groundwater and residual (terminal) water remaining after flood events. These critical components of the water balance of dryland river systems remain largely unknown due to the scarcity of observational data and the difficulty in accurately accounting for the flow distribution in such large multi-channel floodplain systems. While hydrodynamic models can test hypotheses concerning the water balance of infrequent flood events, the scarcity of flow measurement data inhibits model calibration, constrains model accuracy and therefore utility. This paper provides a novel approach to this problem by combining modelling, remotely-sensed data, and limited field measurements, to investigate the partitioning of flood transmissions losses based on seven flood events between February 2006 and April 2012 along a 180 km reach of the Diamantina River in the Lake Eyre Basin, Australia. Transmission losses were found to be high, on average 46% of total inflow within 180 km reach segment or 7 GL/km (range: 4-10 GL/km). However, in 180 km reach, transmission losses vary non-linearly with flood discharge, with smaller flows resulting in higher losses (up to 68%), which diminish in higher flows (down to 24%) and in general there is a minor increase in losses with distance downstream. Partitioning these total losses into the major components shows that actual evaporation was the most significant component (21.6% of total inflow), followed by infiltration (13.2%) and terminal water storage (11.2%). Lateral inflow can be up to 200% of upstream inflow (mean = 86%) and is therefore a critical parameter in the water balance and transmission loss calculations. This study

  20. Design of Parallel Multi-Channel Data Acquisition System Based on Distribution Network%基于分布式网络的并行多通道数据采集系统设计

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

      为满足工业监测指标多元化、站点管理集中化、数据传输实时性要求,构建一种基于分布式网络的并行多通道数据采集系统。远端数据服务中心与监测站点通过GPRS建立数据传输网络,现场监测站点具备网络管理、同步接收监测点数据及实时监测采集状态等功能。采集器硬件采用FPGA与嵌入式PC模块相结合,采用SRAM双缓存机制实现8通道高速同步采集。采用基于VC++多线程技术的网络管理机制,大幅提高了系统采样率指标,应用LabWindows/CVI集成化仪器控件完成信号分析。经仿真实验和应用于轨道监测领域,该系统稳定可靠、扩充性强、维护性好,实现了对多站点、多通道远程在线实时监测。%This paper proposes the multi-channel parallel data acquisition system based on distribution networkwhich is targeted for the demand of multi-index collection, integration of station management and real-time data transmission. With GPRS the wireless network of data transmission is connected between the remote data service center and the on-site unit. When the on-site monitoring unit is built to handle network management, simultaneous collection of data from each station and real-time monitoring for state of every data collection, the collection station is constructed to combine FPGA with embedded PC modules, and it presents high-speed synchronous data collection from eight channels by cache mechanism based on double SRAM. Multi-thread technology of VC++ , so that the sampling rate of the system is improved to a higher stage. Furthermore, the signal processing is completed by using instrument control integrated in LabWindows/CVI. The simulation experiment and application show thatthe track monitoring system is reliable, extensible and maintainable. The system proposed also realizes the remote online monitoring for multi-station and multi-channel data acquisition.

  1. Realization of PLC multi-channel temperature control system based on Modbus protocol%基于Modbus协议的PLC多路温度控制系统的实现

    Institute of Scientific and Technical Information of China (English)

    肖林; 肖哲运; 丁志江

    2011-01-01

    This paper introduces a control system which has the property of cost-effective multi-channel temperature detection. The system is based on Modbus protocol, taking S7-200PLC as master station and SS7-16RTD type thermal resistance input components as slave station under the master-slave mode for real time temperature data transmission, to achieve the heating system's temperature control and data display. The paper shows the realization of system's software and hardware. The system has been used in a number of practical engineering applications successfully.%介绍了一种高性价比的多路温度检测、控制系统,系统基于Modbus通信协议,以主从方式实现西门子S7-200PLC主站与SS7-16RTD型热电阻输入组件从站的实时温度数据传输,完成加热系统的温度控制和数据显示.文中给出了系统软、硬件实现方法,该系统已在多个实际工程中成功应用.

  2. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Müller, F; The ATLAS collaboration; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The signal generator was successfully used as independent test bed for the ATLAS Level-1 Trigger Pre-Processor, providing up to 16 analogue signals.

  3. 基于IV曲线测试的户外多通道光伏组件评测系统%A Multi-channel Outdoor PV Test Evaluation System Based on the IV Curve

    Institute of Scientific and Technical Information of China (English)

    王传才; 朱炬; 朱文星

    2015-01-01

    为准确对户外光伏组件性能进行比对,设计了一款基于IV曲线测试的户外多通道光伏组件评测系统。系统采用便携式计算机作为上位机,与下位机6个数据采集模块和6个探头盒单元之间分别建立串口通信,实现对下位机采集数据的接受、分析和处理。本文对系统的结构、硬软件方案设计进行了介绍,对系统功能进行了实验验证,性能良好。%In order to accurately compare the performance of outd oor PV modules, a multi-channel outdoor PV test evaluation system based on the IV curve is designed. The portable computer is used as the host computer which establishes serial communications with six data acquisition modules and six probe boxes of the lower computer respectively so that the collected data in the lower computer can be accepted, analyzed and processed. The system structure, hardware and software designs are presented, and the good functions of the system are verified by experiments.

  4. 多通道自适应主动噪声控制系统设计及实验%Design and Experiment of Multi-Channel Adaptive Active Noise Control System

    Institute of Scientific and Technical Information of China (English)

    王春云; 吴亚锋; 杨浩; 储妮晟

    2011-01-01

    设计了一种多路自适应主动噪声控制系统,该系统具有4路误差输入和2路抵消输出,详细介绍了系统的设计方法、结构组成和控制原理.利用该系统,在一个普通封闭房间分别完成了对160 Hz单频正弦噪声,三阶谐频噪声和实际录取的某型号潜艇噪声进行了控制实验,分别取得了20 dB、10 dB和8 dB的降噪效果,验证了该系统的可行性和有效性.%A multi-channel self-adaptive active noise control system is designed. It has four error inputs and two offset outputs. Furthermore, the structure, design method and control principle are introduced in detail. Using this system, 160 Hz single-frequency sine noise, the third order harmonic sinusoidal noise and the actual noise from a certain type of submarine are experimented respectively in an ordinary closed room and the effect of 8 dB, 10 dB and 20 dB are obtained respectively. The experimental result verifies the feasibility and effectiveness of the system.

  5. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    In this paper, a method for multi-channel pitch estimation is proposed. The method is a maximum likelihood estimator and is based on a parametric model where the signals in the various channels share the same fundamental frequency but can have different amplitudes, phases, and noise characteristics....... This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  6. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  7. 多通道超声探伤系统中的高速通信接口技术%The High-Speed Communications Interface Technology in Multi-Channel Ultrasonic Inspection System

    Institute of Scientific and Technical Information of China (English)

    桂婧; 李建东

    2011-01-01

    In this paper, using high-speed and high-performance programmable logic device FPGA, with Nios Ⅱ embedded processor, loading μC/OS-Ⅱ real-time operating system, based on NicheStack TCP/IP protocol stack, using Socket API programming, the design of embedded Gigabit Ethernet in a multi-channel ultrasonic inspection system used in testing Hollow shaft of motor car is described in detail. Testing with Wireshark Network Analyzer installed in the host computer, and the results show that data transmission, receiving and sending data are in exactly the same data, no errors and omissions, the transmission speed is stable with continuous 24-hour transmission test.%本文采用高速、高性能可编程逻辑器件FPGA,利用内部NiosⅡ嵌入式处理器,加载μC/OSⅡ实时操作系统,基于NicheStack TCP/IP协议栈,采用Socket API编程,阐述了在动车空心轴无损检测的多通道超声探伤系统中实现嵌入式干兆以太网的过程。实验结果表明:传输数据准确、传输速度稳定。

  8. A Multi-channel Data Acquisition System for Multi-pole Array Sonic Logging Tool%多极子阵列声波测井仪多通道采集系统

    Institute of Scientific and Technical Information of China (English)

    王莹

    2013-01-01

    Designed is a multi-channel synchronous data acquisition system with high precision for multi-pole array sonic logging tool,which can work in high temperature downhole environment.This article introduces the circuit configuration and software design of this system.It uses digital signal processing and complex programmable logic device to control the single-chip with multichannel analog-digital conversion program,which can effectively reduce circuit board size and power consumption.For its acquisition parameters are controllable,the system has good versatility.The system only needs 2 circuit boards of 220 mm × 48 mm to do 16-channel synchronous data acquisition work.Testing result shows that this system has stable performances and can meet the requirement of the multi-pole sonic logging tool.%设计一种用于多级子阵列声波测井仪的高精度多通道同步数据采集系统,可工作于井下高温环境.介绍该系统的电路结构和软件设计思路.该多通道采集系统使用数字信号处理器和复杂可编程逻辑器件控制单片多通道模数转换芯片,有效减小了电路板体积和功耗.由于采集参数可控,该系统有较好的通用性,它完成16通道的采集任务只需要2片220 mm× 48 mm的电路板.测试结果表明,该多通道同步数据采集系统性能稳定,可满足仪器设计要求.

  9. A Fast Image Retrieval Algorithm with Multi-Channel Textural Features in PACS

    Institute of Scientific and Technical Information of China (English)

    ZHANG Dong; YANG Yan; QIN Qian-qing

    2005-01-01

    The paper presents a fast algorithm for image retrieval using multi-channel textural features in medical picture archiving and communication system (PACS). By choosing different linear or nonlinear operators in prediction and update lifting step, the linear or nonlinear M-band wavelet decomposition can be achieved in Mband lifting. It provides the advantages such as fast transform, in-place calculation and integer-integer transform. The set of wavelet moment forms multi-channel textural feature vector related to the texture distribution of each wavelet images. The experimental results of CT image database show that the retrieval approach of multi-channel textural features is effective for image indexing and has lower computational complexity and less memory. It is much easier to implement in hardware and suitable for the applications of real time medical processing system.

  10. Theoretical and numerical characterization of a 40 Gbps long-haul multi-channel transmission system with dispersion compensation

    Directory of Open Access Journals (Sweden)

    Kaikai Xu

    2015-08-01

    Full Text Available When updating the 10 Gbps optical transmission system to 40 Gbps, the main limits are chromatic dispersion, nonlinear effect, especially the interactions of dispersion and intra-channel nonlinearity. To optimize the performance of standard WDM in a 40 Gbps four-channel transmission system, numerical simulations are carried out to compare three different dispersion compensation techniques (without compensation; periodic dispersion compensation at the front end; and dispensation compensation all at the end of the system by means of highly dispersed pulses for chromatic dispersion on a terrestrial 40 Gbps system. Both the loss and dispersion of the transmission fiber are periodically compensated, since two dispersive elements are placed at the input and the output ends of a compensation period. Due to the interplay between dispersion, nonlinearity and signal power, and the effect of dispersion on the pulse evolution, the pulse compress can be optimized and the system performance can be improved to compare with the system with either pre- or post-dispersion compensation. On comparing pre- and post-compensation methods, it is found that the latter is superior to the former. Further performance optimization includes how to properly match the EDFA power and length of the fiber.

  11. Multi-channel Test System for Parameters of Intrinsic Safety Barrier Based On CPLD%基于CPLD的本质安全栅参数多路测试系统

    Institute of Scientific and Technical Information of China (English)

    赵善坤

    2012-01-01

    目前本质安全栅参数的测试多为人工或半自动测试,人为因素影响大,测试结果不能自动保存,设计了1套自动测试本质安全栅参数的系统.采用单片机和CPLD相结合的方案,控制继电器的通断来实现多路测试,并与计算机相连,将测试数据结果上传,实现数据的显示和存储.这样,降低了生产成本,节约了大量资源,提高检测质量和效率,避免了手工测试产生的误差,对企业实现生产自动化起到了重要作用.%At present the parameter of intrinsic safety barrier are most manual or semi-automatic detection,human errors have a great influence,the testing results cannot be automatically saved,this paper designed a set of automatic detection system for intrinsic safety barrier. The system used the scheme of MCU and CPLD, the multi-channel test is achieved by controlling the state of the relays,and the system can upload the measurement data by connecting with a computer,the measurement data can be displayed and stored. Then,it reduces the cost of production and improves the quality and efficiency, and avoids human error. The system plays an important role in achieving production automation.

  12. EQUIPMENTS TO SINGLE PHOTON REGISTRATION. PART 1. FEATURES AND POSSIBILITIES OF MULTI-CHANNEL PHOTODETECTORS WITH INTRINSIC AMPLIFICATION. (REVIEW

    Directory of Open Access Journals (Sweden)

    O. V. Dvornikov

    2012-01-01

    Full Text Available The main types of the modern photo detectors applied to single photon registration are analyzed. It is offered to use silicon photomultipliers for production of multi-channel optoelectronic systems with the single photon resolution.

  13. 基于键盘扫描算法的多路断电报警系统设计%Design of multi-channel outage warning system based on keyboard scanning algorithm

    Institute of Scientific and Technical Information of China (English)

    曾培彬; 黄丹坤

    2012-01-01

    A multi-channel outage warning system was designed based on the keyboard scanning algorithm. The power-off signal is sent to AT89C51 MCU by related interface circuit, and then sent to the monitoring software of PC after detection by the improved keyboard scanning algorithm to perform the remote monitoring of the power supply in the unattended equipment room. The system is concise y can detect multiple power supplies at the same time and generate the results from the analysis of PC software. Due to its high timeliness and accuracy, the system has been put into service in the omnirange radio beacon room of Shantou Air Traffic Management Station of Civil Aviation of China.%在此提出基于键盘扫描算法的多路断电预警系统的设计,通过设计相关的接口电路将断电信号接入AT89C51单片机,经过改进型键盘扫描算法检测后送往PC机监控软件,实现对机房电源的无人远程监控.该系统设计简洁,能对多路电源同时检测,并在PC机软件上进行分析得出结论,预警时效性高,准确性高,目前已在民航汕头空管站信标台机房投入使用.

  14. Study on the Measurement and Control System Based on Multi-channel Wireless Sensing Network%多路通道无线传感网络测控系统的研究

    Institute of Scientific and Technical Information of China (English)

    赵双萍; 邢敬宏; 何辉

    2012-01-01

    针对现有无线测控系统功耗大、传输通道单一、实时性不强等问题,研究设计了基于多路通道的无线传感网络测控系统.利用无线传感网络的感知技术和嵌入式网关的传输技术,通过WiFi、GPRS、3G、IP中的任意一种连接方式,实现了嵌入式网关与Intemet服务器的通信;应用HTML5和RTMP技术,研发了基于Web的HMI软件,实现了手机个人数字助理(PDA)等移动终端的访问.运行结果表明,该系统保证了数据传输的可靠性和实时性,具有一定的实际参考价值.%Aiming at the disadvantages of currently existing wireless measurement and control systems, such as large power consumption, single transmission channel and poor real-time performance; the measurement and control system based on multi-channel wireless sensing network is researched and designed. By adopting sensation technology of wireless sensing network and transmission technology of embedded gateway, the communication between embedded gateway and Internet server through any connection method of WiFi, GPRS, 3G or IP, is implemented. Hie technologies of HTML5 and RTMP are applied to research and develop the Web-based HMI software, the access of mobile terminal such as cell phone personal digital assistant (PDA) is implemented. The running result shows that the system guarantees the reliability and real-time performance of data transmission, and possesses certain reference value.

  15. Capacity Expansion and Allocation of Logistics System in a Multi-channel Supply Chain%多渠道供应链中物流系统的容量扩充与分配模型

    Institute of Scientific and Technical Information of China (English)

    刘开军; 张子刚

    2009-01-01

    When a traditional supplier extends her business from the single channel of in-store retailers to the multi-channel of in-store retailers and e-retailers, she needs to expand her logistics system to supply the new demands from online customers. This paper considers a two-echelon logistics system consisting of a center warehouse and several district warehouses. A capacity expansion and allocation model (CEAM) is developed with the structure of current logistics system unchanged. And a Lagrangian relaxation algorithm is designed to solve CEAM. Numerical experiments show the efficiency of the algorithm and illustrate the trade off between transportation cost and inventory pooling effect when searching for the optimal solution.%考虑一个传统供应链将市场由单一的实体商店零售扩大到互联网上的在线零售,为满足新增的在线零售需求,供应商需要扩充物流系统的供应容量,并设计新增容量的分配方案.本文针对由一个中心仓库和多个地区仓库组成的二级物流系统,在保留现有配送网络结构的基础上,构建了物流系统的容量扩充与分配模型,并提出一种基于拉格朗日松弛法的求解算法.我们通过数值实验表明了算法的有效性,并通过数值算例说明了运输成本与库存汇聚效应对最优容量扩充与分配方案的影响.

  16. Design of Multi-channel and High-accuracy Data Acquisition Circuit for Battery Management System%电池管理系统多通道高精度数据采集电路设计

    Institute of Scientific and Technical Information of China (English)

    魏海波; 梅建伟; 简炜

    2015-01-01

    According to the accuracy requirement of testing data for the battery management system, a multi-channel and high precision A/D data acquisition circuit was designed based on ADS7953 digital converter. Using dual operational amplifier LM358, the relevant data of the battery voltage, charge-and-discharge bidirectional current and working temperature were obtained and sent to A/D converter, from which the output digital signal was then transmitted to MCU for the subsequent data evaluation. The ex⁃perimental results show the circuit meets the accuracy requirement of data testing of the battery manage⁃ment system, and provides a guarantee for the reliability assessment of the battery management system.%根据电池管理系统对检测数据的精度要求,设计了基于ADS7953模数转换器的多通道高精度A/D数据采集电路。利用双运放LM358获取了动力电池的电压、充放电双向电流、工作温度等相关数据,经过模数转换器转换成数字信号送入MCU后,转入后续的数据评估处理过程。经过实验验证,该设计电路满足电池管理系统检测数据的精度要求,为电池管理系统的可靠性评估提供了保障。

  17. Detecting Multi-ChannelWireless Microphone User Emulation Attacks in White Space with Noise

    Directory of Open Access Journals (Sweden)

    Dan Shan

    2014-07-01

    Full Text Available Cognitive radio networks (CRNs are susceptible to primary user emulation (PUE attacks. Conventional PUE attack detection approaches consider television broadcasting as the primary user. In this work, however, we study a special kind of PUE attack named wireless microphone user emulation (WMUE attack. Existing work on WMUE attack detection deals with single channel senario. Although multi-channelWM(MCWM systems are common, detecting WMUE attacks under a multi-channel setting in noisy environments has not been well studied. In this work, we propose a novelmulti-channelWMUEattack detection scheme which operates in low signal-to-noise ratio (SNR environments with low computational complexity, thanks to the first 1.5-bit FM demodulator whose outputs are represented by only 0, 1 and -1. Experimental results show that, the proposed scheme can effectively detect multi-channel WMUE attacks within 0.25 second when SNR is lower than 6 dB.

  18. A portable, multi-channel fNIRS system for prefrontal cortex: Preliminary study on neurofeedback and imagery tasks (Conference Presentation)

    Science.gov (United States)

    Paik, Seung-ho; Kim, Beop-Min

    2016-03-01

    fNIRS is a neuroimaging technique which uses near-infrared light source in the 700-1000 nm range and enables to detect hemodynamic changes (i.e., oxygenated hemoglobin, deoxygenated hemoglobin, blood volume) as a response to various brain processes. In this study, we developed a new, portable, prefrontal fNIRS system which has 12 light sources, 15 detectors and 108 channels with a sampling rate of 2 Hz. The wavelengths of light source are 780nm and 850nm. ATxmega128A1, 8bit of Micro controller unit (MCU) with 200~4095 resolution along with MatLab data acquisition algorithm was utilized. We performed a simple left and right finger movement imagery tasks which produced statistically significant changes of oxyhemoglobin concentrations in the dorsolateral prefrontal cortex (dlPFC) areas. We observed that the accuracy of the imagery tasks can be improved by carrying out neurofeedback training, during which a real-time feedback signal is provided to a participating subject. The effects of the neurofeedback training was later visually verified using the 3D NIRfast imaging. Our portable fNIRS system may be useful in non-constraint environment for various clinical diagnoses.

  19. THE IMPLEMENTATION OF THE MULTI-CHANNEL RADIATION DETECTION SYSTEM BASED ON WSN%基于无线传感网络的多点辐射监测系统的实现

    Institute of Scientific and Technical Information of China (English)

    周伟; 方方; 周建斌; 李扬红; 刘易; 李琳琳

    2011-01-01

    介绍了一种新型基于无线传感网络的多点辐射监测系统的实现.阐述了采用G-M管作为辐射探测器,以time-to-count技术作为测量方法,基于无线传感网络完成多点辐射强度检测的软、硬件实现技术要点.无线传感网 络是由大量传感器结点通过无线通信技术自组织构成的网络,能够对监测区域内的信息进行实时协作的监测、采集、处理和传输.为提高数据传输的可靠性,系统采用监测节点、汇聚节点和中心控制节点的多维异构网络结构.%The implementation of an up-to-date multi-channel radiation detecting system based on WSN (wireless sensor network)is presented in this paper. The technical points of software and hardware, such as using G-M tube as a detector, time-to-count measurement method and WSN, are also described in detail. Wireless sensor network is the one with which a number of sensor nodes are self-organized through wireless communication. And it can implement data detecting, acquiring, processing and transmitting real-timely and concurrently. For the purpose of improving the reliability of data transmission, the system is made up of three-tiered heterogeneous architecture consisting of detecting node, sinking node and central control node.

  20. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    Energy Technology Data Exchange (ETDEWEB)

    Akindinov, A. [Institute for Theoretical and Experimental Physics (ITEP), B. Cheremushkinskaya 25, Moscow 117218 (Russian Federation)], E-mail: Alexander.Akindinov@cern.ch; Golovin, V. [Center of Perspective Technologies and Apparatus (CPTA), Preobrazhenskaya pl. 6/8, Moscow 107076 (Russian Federation); Grigoriev, E. [University of Geneva, CMU, rue Michel-Servet 1, Geneve 4, 1211 (Switzerland); Grishuk, Yu. [Institute for Theoretical and Experimental Physics (ITEP), B. Cheremushkinskaya 25, Moscow 117218 (Russian Federation); Kuleshov, S. [Institute for Theoretical and Experimental Physics (ITEP), B. Cheremushkinskaya 25, Moscow 117218 (Russian Federation); Departamento de Fisica y Centro de Estudios Subatomicos, Universidad Tecnica Federico Santa Maria, Castilla 110-V, Valparaiso (Chile); Mal' kevich, D.; Martemiyanov, A.; Nedosekin, A.; Ryabinin, M.; Voloshin, K. [Institute for Theoretical and Experimental Physics (ITEP), B. Cheremushkinskaya 25, Moscow 117218 (Russian Federation)

    2009-10-21

    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new technique, scintillation tile with MRS APD light readout (START). In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure (MRS APD) operated in the Geiger mode. START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10{sup -2}Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 h, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

  1. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    CERN Document Server

    Akindinov, A.; Grigoriev, E.; Grishuk, Yu.; Kuleshov, S.; Mal'kevich, D.; Martemiyanov, A.; Nedosekin, A.; Ryabinin, M.; Voloshin, K.

    2009-01-01

    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

  2. 高速多通道CCD信号并行处理系统%High-Speed Multi-Channel CCD Signal Parallel Processing System

    Institute of Scientific and Technical Information of China (English)

    张达; 徐抒岩

    2008-01-01

    为解决目前很多高速CCD(Charge Coupled Device)应用系统数据输出路数多,数据率高的问题,提出一种并行处理高速多通道CCD信号的系统架构,阐述了该系统的架构组成和实现方案,并对设计要点进行了分析.该系统采用FPGA(Filed Programmble Gate Array),时分复用,LVDS(Low Voltage Differential Signal)和SCSI(Small Computer System Interface)存储等技术.研究结果表明,该设计具有较好的稳定性,灵活性和通用性等,并已成功应用于某8通道高速TDICCD(Time Delay Integration Charge Couple Device)成像系统的设计中,数据率高达1.28 Gbit/s.

  3. COMPARISON OF VARIOUS APPROACHES TO MULTI-CHANNEL INFORMATION FUSION IN C-OTDR SYSTEMS FOR REMOTE MONITORING OF EXTENDED OBJECTS

    Directory of Open Access Journals (Sweden)

    A. V. Timofeev

    2015-01-01

    Full Text Available The paper presents new results concerning selection of optimal information fusion formula for ensembles of COTDR channels. Here C-OTDR is a coherent optical time domain reflectometer. Each of these channels provides data for appropriate automatic classifier which is designed to classify the elastic vibration sources in the multiclass case. Those classifiers form a so-called classifiers ensemble. Ensembles of Lipschitz Classifiers were considered. In this case the goal of information fusion is to create an integral classificator designed for effective classification of seismoacoustic target events. The Matching Pursuit Optimization Ensemble Classifiers (MPOEC, the Linear Programming Boosting (LP-Boost (LP-β and LP-B variants, the Multiple Kernel Learning (MKL, and Weighing of Inversely as Lipschitz Constants (WILC approaches were compared. The WILC is a brand new approach to optimal fusion of Lipschitz Classifiers Ensembles. The basics of these methods have been briefly described along with intrinsic features. All of those methods are based on reducing the task of choosing convex hull parameters to a solution of an optimization problem. All of the mentioned approaches can be successfully used for using in the C-OTDR system data processing. Results of practical usage are presented.

  4. A Long-wire-connected and Multi-channel 3D Network-on-chip Design for Many-core System

    Directory of Open Access Journals (Sweden)

    Tan Hai

    2013-07-01

    Full Text Available To reduce traffic jam caused by various data competitions for channel, we present a low delay and energy efficient network-on-chip with three channels for different type’s data. Hence, the transmission for control data between cores won’t be congested by the big amount of data transmitted from caches to core, and it achieves better performance in latency and energy. Our strategy is to make a directive long wire to connect two nodes in the same row or column, and distribute these connective wires to different layers which are connected by 3D stacking technology. In the many-core system applied with this topology, every pair of core-cache nodes are at most 5 hops away while real-time and short control information is transmitted by a 2D mesh network. The experimental results show up to 23% of network latency reduction and up to 15% energy reduction when compared to a 3D network-on-chip.

  5. Application of Dual-clock FIFO in the Multi-channel High Speed Transmission System%双时钟FIFO在多通道高速传输系统中的应用

    Institute of Scientific and Technical Information of China (English)

    郑争兵

    2013-01-01

    介绍了一种跨时钟域传递数据的双时钟FIFO模型,并给出了该模型使用状态信号rdusedw和wrusew产生空、满状态标志信号的控制方法.利用双时钟FIFO设计了多通道高速传输接口电路,在QuartusⅡ9.0软件开发平台上进行电路时序仿真.结果表明FIFO调度模块能够控制4对双时钟FIFO的数据流切换和分流,实现基于FPGA的主接收板与从发送板之间的高速数据通信.高速传输系统接口电路设计灵活,具有很好实用价值.%A dual-clock FIFO model with data transfers crossing different clock domains was introduced,and the control method about how the model used state signals rdusedw and wrusedw to produce state signals of empty and full marks was given.The multi-channel high-speed transmission interface circuit was designed to use the dual-clock FIFO and its timing simulation was accomplished in the software development platform QuartusⅡ9.0.The results show that the FIFO scheduling module can control the four pairs of dual-clock FIFO data stream switching and diversion,and achieve high-speed data communication between the main receiver board and the subordinate transmitter board based on FPGA.The design of the high-speed transmission system interface circuit is flexible and has good practical value.

  6. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2008-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized throughput maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  7. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized through- put maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  8. Stacked, Filtered Multi-Channel X-Ray Diode Array

    Energy Technology Data Exchange (ETDEWEB)

    MacNeil, Lawrence P. [National Security Technologies, LLC; Dutra, Eric C. [National Security Technologies, LLC; Raphaelian, Mark; Compton, Steven [Lawrence Livermore National Laboratory; Jacoby, Barry [Lawrence Livermore National Laboratory

    2015-08-01

    This system meets the need for a low-cost, robust X-ray diode array to use for experiments in hostile environments on multiple platforms, and for experiments utilizing forces that may destroy the diode(s). Since these uses require a small size with a minimal single line-of-sight, a parallel array often cannot be used. So a stacked, filtered multi-channel X-ray diode array was developed that was called the MiniXRD. The design was modeled, built, and tested at National Security Technologies, LLC (NSTec) Livermore Operations (LO) to determine fundamental characteristics. Then, several different systems were fielded as ancillary “ridealong” diagnostics at several national facilities to allow us to iteratively improve the design and usability. Presented here are design considerations and experimental results. This filtered diode array is currently at Technical Readiness Level (TRL) 6.

  9. Pixel-Wise-Inter/Intra-Channel Color and Luminance Uniformity Corrections for Multi-Channel Projection Displays

    Science.gov (United States)

    2016-08-11

    Journal Article 3. DATES COVERED (From – To) Jan 2015 – Dec 2015 4. TITLE AND SUBTITLE PIXEL-WISE INTER /INTRA-CHANNEL COLOR & LUMINANCE UNIFORMITY...Conference Dayton, Ohio – 28-29 June 2016 14. ABSTRACT Inter - and intra-channel color and luminance are generally non-uniform in multi-channel...projection display systems. Several methods have been proposed to correct for both inter - and intra-channel color and luminance variation in multi-channel

  10. Performance of Multi-Channel DBP with Long-haul Frequency-Referenced Transmission

    DEFF Research Database (Denmark)

    Porto da Silva, Edson; Da Ros, Francesco; Zibar, Darko

    2016-01-01

    The impact of frequency referenced WDM source on the performance of dual polarization multi-channel digital backpropagation (MC-DBP) is experimentally investigated up to 4000 km of transmission. For a system with 4 × 8 GBd DP-QPSK, such approach allows 0.6 dB more MC-DBP Q2-factor gain in the non...

  11. On the relationship between multi-channel envelope and temporal fine structure

    DEFF Research Database (Denmark)

    2011-01-01

    The envelope of a signal is broadly defined as the slow changes in time of the signal, where as the temporal fine structure (TFS) are the fast changes in time, i.e. the carrier wave(s) of the signal. The focus of this paper is on envelope and TFS in multi-channel systems. We discuss the differenc...

  12. Multi-channel Testing and Diagnosis System for Certain Type Power Based on CPCI%基于CPCI的某电源设备多通道测试诊断系统

    Institute of Scientific and Technical Information of China (English)

    范利军; 杜国祥

    2016-01-01

    Aiming at the problem that the current detection method can’t meet the needs of the maintenance of the search-radar power supply, a multi-channel testing and diagnosis system based on CPCI bus is designed. The system uses AD210 chip to isolate the measured signal, and uses the CPCI8622 multi-function acquisition card to convert analog voltage signals into digital signals. At last, the digital signals are transmitted to the PC industrial control computer through the CPCI bus, in addition, analyzed and judged by the test software. The experiment results show that the system has the characteristics of convenient operation, portability, high precision, fast and accurate fault diagnosis, and the system realizes the function of parameter online testing and fault diagnosis, and meet the test requirements of radar power in a variety of environments.%针对现有测试方法不能满足搜索雷达电源的维修保障需求的问题,设计一种基于 CPCI 总线的多通道测试诊断系统。该系统采用AD210芯片对被测信号进行隔离,利用CPCI8622多功能采集卡将隔离后的模拟电压信号转换为数字信号,最终通过CPCI总线传输至PC工控机,并由测试软件对获取的数据信息进行综合分析和判断。实验结果表明:该系统具有操作简单、携带方便、测试精度高、故障诊断快速准确等特点,实现了参数在线测试和故障诊断功能,能够满足多种环境对雷达电源测试的要求。

  13. Normalized Design of Multi-channel LIF Digital Receiver

    Institute of Scientific and Technical Information of China (English)

    方航锋; 郁发兴; 汪海航

    2004-01-01

    A design method for parallel processing application on multi-channel low-intermediate-frequency(LIF) digital receiver was presented. It is based on the DSP sub-array with a simple topology and operation timing to evaluate and determine the processing capability and then construct the parallel processing array for multi-channel signals according to the restriction of operation timing. Using this method, the design of multi-channel digital receiver may be simplified. Finally, a design example was used to show how to apply this method.

  14. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  15. Multi-Channel Optical Digitizer for Earth Sciences Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective was to design and manufacture a multi-channel high resolution analog-digital converter for digitizing a CCD image signal. The tasks included...

  16. Monolithic DWDM Multi-channel planar waveguide laser

    DEFF Research Database (Denmark)

    Sckerl, Mads W.; Guldberg-Kjær, Søren Andreas; Laurent-Lund, Christian

    1999-01-01

    silica -on-silicon-based multi-channel waveguide laser with four outputs channel with ~ 50 GHz spacing is presented. Excellent control over channel positions and spacings is obtained by the method presented here. Remarkable temperature tuning properties have been obtained.......silica -on-silicon-based multi-channel waveguide laser with four outputs channel with ~ 50 GHz spacing is presented. Excellent control over channel positions and spacings is obtained by the method presented here. Remarkable temperature tuning properties have been obtained....

  17. General Model for Infrastructure Multi-channel Wireless LANs

    OpenAIRE

    Fayez Gebali; Abdelsalam Amer

    2010-01-01

    In this paper we develop an integrated model for request mechanism and data transmission in multi-channel wireless local area networks. We calculated the performance parameters for single and multi-channel wireless networks when the channel is noisy. The proposed model is general it can be applied to different wireless networks such as IEEE802.11x, IEEE802.16, CDMA operated networks and Hiperlan\\2.

  18. Multi-Channel neurodegenerative pattern analysis and its application in Alzheimer's disease characterization.

    Science.gov (United States)

    Liu, Sidong; Cai, Weidong; Wen, Lingfeng; Feng, David Dagan; Pujol, Sonia; Kikinis, Ron; Fulham, Michael J; Eberl, Stefan

    2014-09-01

    Neuroimaging has played an important role in non-invasive diagnosis and differentiation of neurodegenerative disorders, such as Alzheimer's disease and Mild Cognitive Impairment. Various features have been extracted from the neuroimaging data to characterize the disorders, and these features can be roughly divided into global and local features. Recent studies show a tendency of using local features in disease characterization, since they are capable of identifying the subtle disease-specific patterns associated with the effects of the disease on human brain. However, problems arise if the neuroimaging database involved multiple disorders or progressive disorders, as disorders of different types or at different progressive stages might exhibit different degenerative patterns. It is difficult for the researchers to reach consensus on what brain regions could effectively distinguish multiple disorders or multiple progression stages. In this study we proposed a Multi-Channel pattern analysis approach to identify the most discriminative local brain metabolism features for neurodegenerative disorder characterization. We compared our method to global methods and other pattern analysis methods based on clinical expertise or statistics tests. The preliminary results suggested that the proposed Multi-Channel pattern analysis method outperformed other approaches in Alzheimer's disease characterization, and meanwhile provided important insights into the underlying pathology of Alzheimer's disease and Mild Cognitive Impairment.

  19. FPGA-based multi-channel fluorescence lifetime analysis of Fourier multiplexed frequency-sweeping lifetime imaging.

    Science.gov (United States)

    Zhao, Ming; Li, Yu; Peng, Leilei

    2014-09-22

    We report a fast non-iterative lifetime data analysis method for the Fourier multiplexed frequency-sweeping confocal FLIM (Fm-FLIM) system [Opt. Express 22, 10221 (2014)]. The new method, named R-method, allows fast multi-channel lifetime image analysis in the system's FPGA data processing board. Experimental tests proved that the performance of the R-method is equivalent to that of single-exponential iterative fitting, and its sensitivity is well suited for time-lapse FLIM-FRET imaging of live cells, for example cyclic adenosine monophosphate (cAMP) level imaging with GFP-Epac-mCherry sensors. With the R-method and its FPGA implementation, multi-channel lifetime images can now be generated in real time on the multi-channel frequency-sweeping FLIM system, and live readout of FRET sensors can be performed during time-lapse imaging.

  20. Multi-channel support for DMAC in WSNs

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Currently most wireless sensor network applications assume the presence of single-channel medium access control (MAC) protocols. However, lower sensing range result in dense networks, single-channel MAC protocols may be inadequate due to higher demand for the limited bandwidth. In this paper we proposed a method of multi-channel support for DMAC in Wireless sensor networks (WSNs). The channel assignment method is based on local information of nodes. Our multi-channel DMAC protocol implement channel distribution before message collecting from source nodes to sink node and made broadcasting possible in DMAC. Analysis and simulation result displays this multi-channel protocol obviously decreases the latency without increasing energy consumption.

  1. A multi-channel high time resolution detector for high content imaging

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    Medical imaging has long benefited from advances in photon counting detectors arising from space and particle physics. We describe a microchannel plate-based detector system for high content (multi-parametric) analysis, specifically designed to provide a step change in performance and throughput for measurements in imaged live cells and tissue for the ‘omics’. The detector system integrates multi-channel, high time resolution, photon counting capability into a single miniaturized detector with integrated ASIC electronics, comprising a fast, low power amplifier discriminator and TDC for every channel of the discrete pixel electronic readout, and achieving a pixel density improvement of order two magnitudes compared with current comparable devices. The device combines high performance, easy reconfigurability, and economy within a compact footprint. We present simulations and preliminary measurements in the context of our ultimate goals of 20 ps time resolution with multi-channel parallel analysis (1024 chan...

  2. USB2.0接口多通道数据采集和实时显示系统的设计%Design of Multi-channel Data Acquisition and Real-time Display About USB2.0 Interface System

    Institute of Scientific and Technical Information of China (English)

    林宁; 陈新

    2012-01-01

    Basic solutions to problems on matching the acquisition speed and processing speed are introduced. According to these solutions, the advanced application is designed for multi-channel USB2.0 data acquisition system, using Visual C ++ . NET 2005 application development platform. By using multithreading, circle buffer, GDI and double buffered graphics technologies, the system can display smooth scrolling or refreshing multi-channel waveforms without flicker while saving a large amount of data on hard disk. It can help researchers to understand the real-time data acquisition situation.%分析USB2.0多通道数据采集与显示系统中数据采集速度和处理速度难以匹配等问题,并阐述其基本解决方法,据此采用Visual C++.NET 2005平台开发了一个高级应用程序.通过多线程、循环缓存、GDI、显示双缓存等技术,实现在硬盘上保存大量数据的同时,在显示器上以滚动或刷新的方式完整并无闪烁地显示采集所获得的多通道信号波形,便于研究者及时了解数据的实时采集情况.

  3. Handling Deafness Problem of Scheduled Multi-Channel Polling MACs

    Science.gov (United States)

    Jiang, Fulong; Liu, Hao; Shi, Longxing

    Combining scheduled channel polling with channel diversity is a promising way for a MAC protocol to achieve high energy efficiency and performance under both light and heavy traffic conditions. However, the deafness problem may cancel out the benefit of channel diversity. In this paper, we first investigate the deafness problem of scheduled multi-channel polling MACs with experiments. Then we propose and evaluate two schemes to handle the deafness problem. Our experiment shows that deafness is a significant reason for performance degradation in scheduled multi-channel polling MACs. A proper scheme should be chosen depending on the traffic pattern and the design objective.

  4. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm.

    Science.gov (United States)

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-08-13

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  5. An interactive visualization tool for multi-channel confocal microscopy data in neurobiology research

    KAUST Repository

    Yong Wan,

    2009-11-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist\\'s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system.

  6. Dense Clustered Multi-Channel Wireless Sensor Cloud

    Directory of Open Access Journals (Sweden)

    Sivaramakrishnan Sivakumar

    2015-08-01

    Full Text Available Dense Wireless Sensor Network Clouds have an inherent issue of latency and packet drops with regards to data collection. Though there is extensive literature that tries to address these issues through either scheduling, channel contention or a combination of the two, the problem still largely exists. In this paper, a Clustered Multi-Channel Scheduling Protocol (CMSP is designed that creates a Voronoi partition of a dense network. Each partition is assigned a channel, and a scheduling scheme is adopted to collect data within the Voronoi partitions. This scheme collects data from the partitions concurrently and then passes it to the base station. CMSP is compared using simulation with other multi-channel protocols like Tree-based Multi-Channel, Multi-Channel MAC and Multi-frequency Media Access Control for wireless sensor networks. Results indicate CMSP has higher throughput and data delivery ratio at a lower power consumption due to network partitioning and hierarchical scheduling that minimizes load on the network.

  7. The Art of Multi-channel Hypermedia Application Development

    NARCIS (Netherlands)

    Synodinos, Dionysios G.; Avgeriou, Paris

    2003-01-01

    The plethora of networked devices and platforms that continuously come to light, as well as the emergence of alternative ways to access the internet, have increased the demand for multi-channel access to hypermedia applications. Researchers and practitioners nowadays not only have to deal with the c

  8. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630 cu

  9. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies

  10. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies multi-chann

  11. Multi-channel MAC Protocol in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Yongli Sun

    2013-11-01

    Full Text Available Since cognitive wireless network (CRN has the characteristic of secondary use, it can enable the device to dynamically access available spectrum without interference to primary users (PUs, which can effectively alleviate contradiction between the lack of spectrum resources and the growing demand for wireless access. However, Medium Access Control (MAC protocol as CRN core components, can achieve competition access of the licensed spectrum and coordination control, which will maximize spectrum utilization efficiency and network throughput. The contribution of this survey is threefold. First, we analyze the characteristics of the existed multi- channel MAC protocol in CRN; Second, according to the different ways of spectrum access in CRNs, the multi-channel MAC protocols are classified into time-slotted based MAC protocol, control channel based MAC protocol and hybrid MAC protocol, and the paper emphatically analyzed the advantages and disadvantages of these multi-channel MAC protocols; Finally, the paper explores the difficulties and the challenges of multi-channel MAC protocols design in cognitive wireless network.

  12. Stacked, filtered multi-channel X-ray diode array

    Science.gov (United States)

    MacNeil, L. P.; Dutra, E. C.; Compton, S. M.; Jacoby, B. A.; Raphaelian, M. L.

    2015-08-01

    There are many types of X-ray diodes that are used for X-ray flux or spectroscopic measurements and for estimating the spectral shape of the VUV to soft X-ray spectrum. However, a need arose for a low cost, robust X-ray diode to use for experiments in hostile environments on multiple platforms, and for experiments that utilize forces that may destroy the diode(s). Since the typical proposed use required a small size with a minimal single line-of-sight, a parallel array could not be used. So, a stacked, filtered multi-channel X-ray diode array was developed, called the MiniXRD. To achieve significant cost savings while maintaining robustness and ease of field setup, repair, and replacement, we designed the system to be modular. The filters were manufactured in-house and cover the range from 450 eV to 5000 eV. To achieve the line-of-sight accuracy needed, we developed mounts and laser alignment techniques. We modeled and tested elements of the diode design at NSTec Livermore Operations (NSTec / LO) to determine temporal response and dynamic range, leading to diode shape and circuitry changes to optimize impedance and charge storage. We fielded individual and stacked systems at several national facilities as ancillary `ride-along' diagnostics to test and improve the design usability. We present the MiniXRD system performance which supports consideration as a viable low-cost alternative for multiple-channel low-energy X-ray measurements. This diode array is currently at Technical Readiness Level (TRL) 6.

  13. Stacked, filtered multi-channel X-ray diode array

    Energy Technology Data Exchange (ETDEWEB)

    MacNeil, Lawrence [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Dutra, Eric [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Raphaelian, Mark [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Compton, Steve [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jacoby, Barry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-08-01

    There are many types of X-ray diodes used for X-ray flux or spectroscopic measurements and for estimating the spectral shape of the VUV to soft X-ray spectrum. However, a need exists for a low-cost, robust X-ray diode to use for experiments in hostile environments on multiple platforms, and for experiments that utilize forces that may destroy the diode(s). Since the typical proposed use required a small size with a minimal single line-of-sight, a parallel array could not be used. So, a stacked, filtered multi-channel X-ray diode array was developed, called the MiniXRD. To achieve significant cost savings while maintaining robustness and ease of field setup, repair, and replacement, we designed the system to be modular. The filters were manufactured in-house and cover the range from 450 eV to 5000 eV. To achieve the line-of-sight accuracy needed, we developed mounts and laser alignment techniques. We modeled and tested elements of the diode design at NSTec Livermore Operations (NSTec / LO) to determine temporal response and dynamic range, leading to diode shape and circuitry changes to optimize impedance and charge storage. The authors fielded individual and stacked systems at several national facilities as ancillary "ride-along" diagnostics to test and improve the design usability. This paper presents the MiniXRD system performance, which supports consideration as a viable low-costalternative for multiple-channel low-energy X-ray measurements. This diode array is currently at Technical Readiness Level (TRL) 6.

  14. Autonomic Nervous System Disorders

    Science.gov (United States)

    Your autonomic nervous system is the part of your nervous system that controls involuntary actions, such as the beating of your heart ... breathing and swallowing Erectile dysfunction in men Autonomic nervous system disorders can occur alone or as the result ...

  15. Feature Extraction for the Analysis of Multi-Channel EEG Signals Using Hilbert- Huang Technique

    Directory of Open Access Journals (Sweden)

    Mahipal Singh

    2016-02-01

    Full Text Available This research article seeks to propose a Hilbert-Huang transform (HHT based novel feature extraction approach for the analysis of multi-channel EEG signals using its local time scale features. The applicability of this recently developed HHT based new features has been investigated in the analysis of multi-channel EEG signals for classifying a small set of non-motor cognitive task. HHT is combination of multivariate empirical mode decomposition (MEMD and Hilbert transform (HT. At the first stage, multi-channel EEG signals (6 channels per trial per task per subject corresponding to a small set of nonmotor mental task were decomposed by using MEMD algorithm. This gives rise to adaptive i.e. data driven decomposition of the data into twelve mono component oscillatory modes known as intrinsic mode functions (IMFs and one residue function. These generated intrinsic mode functions (IMFs are multivariate i.e. mode aligned and narrowband. From the generated IMFs, most sensitive IMF has been chosen by analysing their power spectrum. Since IMFs are amplitude and frequency modulated, the chosen IMF has been analysed through their instantaneous amplitude (IA and instantaneous frequency (IF i.e. local features extracted by applying Hilbert transform on them. Finally, the discriminatory power of these local features has been investigated through statistical significance test using paired t-test. The analysis results clearly support the potential of these local features for classifying different cognitive task in EEG based Brain –Computer Interface (BCI system.

  16. Load-Adaptive Practical Multi-Channel Communications in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Choong Seon Hong

    2010-09-01

    Full Text Available In recent years, a significant number of sensor node prototypes have been designed that provide communications in multiple channels. This multi-channel feature can be effectively exploited to increase the overall capacity and performance of wireless sensor networks (WSNs. In this paper, we present a multi-channel communications system for WSNs that is referred to as load-adaptive practical multi-channel communications (LPMC. LPMC estimates the active load of a channel at the sink since it has a more comprehensive view of the network behavior, and dynamically adds or removes channels based on the estimated load. LPMC updates the routing path to balance the loads of the channels. The nodes in a path use the same channel; therefore, they do not need to switch channels to receive or forward packets. LPMC has been evaluated through extensive simulations, and the results demonstrate that it can effectively increase the delivery ratio, network throughput, and channel utilization, and that it can decrease the end-to-end delay and energy consumption.

  17. Noise Removal Using Multi-Channel Coherence

    Science.gov (United States)

    2010-12-01

    Atlantique ; décembre 2010. Introduction : La suppression du bruit de fond à des capteurs magnétiques posés sur le fond a des applications dans les... applications , in- cluding mine warfare systems and ocean surveillance systems. Decreasing the background magnetic noise by 10-20 dB will allow the detection of...océanique peut être réduit au moyen d’un capteur de pression co-implanté et d’un autre magnétomètre, situé à une certaine distance. À cette n

  18. Multi-Channel Noise Reduced Visual Evoked Potential Analysis

    Science.gov (United States)

    Palaniappan, Ramaswamy; Raveendran, Paramesran; Nishida, Shogo

    In this paper, Principal Component Analysis (PCA) is used to reduce noise from multi-channel Visual Evoked Potential (VEP) signals. PCA is applied to reduce noise from multi-channel VEP signals because VEP signals are more correlated from one channel to another as compared to noise during visual perception. Emulated VEP signals contaminated with noise are used to show the noise reduction ability of PCA. These noise reduced VEP signals are analysed in the gamma spectral band to classify alcoholics and non-alcoholics with a Fuzzy ARTMAP (FA) neural network. A zero phase Butterworth digital filter is used to extract gamma band power in spectral range of 30 to 50 Hz from these noise reduced VEP signals. The results using 800 VEP signals give an average FA classification of 92.50 % with the application of PCA and 83.33 % without the application of PCA.

  19. Mimicking multi-channel scattering with single-channel approaches

    OpenAIRE

    Grishkevich, Sergey; Schneider, Philipp-Immanuel; Vanne, Yulian V.; Saenz, Alejandro

    2009-01-01

    The collision of two atoms is an intrinsic multi-channel (MC) problem as becomes especially obvious in the presence of Feshbach resonances. Due to its complexity, however, single-channel (SC) approximations, which reproduce the long-range behavior of the open channel, are often applied in calculations. In this work the complete MC problem is solved numerically for the magnetic Feshbach resonances (MFRs) in collisions between generic ultracold 6Li and 87Rb atoms in the ground state and in the ...

  20. Efficient sequential compression of multi-channel biomedical signals

    OpenAIRE

    Capurro, Ignacio; Lecumberry, Federico; Martín, Álvaro; Ramírez, Ignacio; Rovira, Eugenio; Seroussi, Gadiel

    2016-01-01

    This work proposes lossless and near-lossless compression algorithms for multi-channel biomedical signals. The algorithms are sequential and efficient, which makes them suitable for low-latency and low-power signal transmission applications. We make use of information theory and signal processing tools (such as universal coding, universal prediction, and fast online implementations of multivariate recursive least squares), combined with simple methods to exploit spatial as well as temporal re...

  1. Multi-channel analyzer controlled by applet and flash

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Both java applet and flash were applied to emulate virtual panel of multi-channel pulse height analyzer (MCA), and Microsoft IE browser was used to control MCA through internet to measure the γ-ray energy spectrum of 137Cs. It Was shown that most of the work completed by applet can be done by flash too, and with flash, more beautiful panel of the remote controlled instruments can be easily designed.

  2. Parallel Multi Channel Convolution using General Matrix Multiplication

    OpenAIRE

    VASUDEVAN, ARAVIND; Anderson, Andrew; Gregg, David

    2017-01-01

    Convolutional neural networks (CNNs) have emerged as one of the most successful machine learning technologies for image and video processing. The most computationally intensive parts of CNNs are the convolutional layers, which convolve multi-channel images with multiple kernels. A common approach to implementing convolutional layers is to expand the image into a column matrix (im2col) and perform Multiple Channel Multiple Kernel (MCMK) convolution using an existing parallel General Matrix Mul...

  3. A high-throughput, multi-channel photon-counting detector with picosecond timing

    Science.gov (United States)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  4. Design and experiment of performance testing system of multi-channel seed-metering device based on time intervals%基于时间间隔的多路精量排种器性能检测系统设计与试验

    Institute of Scientific and Technical Information of China (English)

    丁幼春; 王雪玲; 廖庆喜; 李明

    2016-01-01

    Precision metering device is the core component of seed drills, its performance determines the seeding qualities. At present, precision metering device has difficulty achieving a top seeding performance during the working time and avoiding loss sowing. Hence a seeding performance detection system must be innovated for precision seeding device to evaluate seeding performance, especially for multi-channel seeding device of rapeseed. So to be able to detect seeding performance such as normal index, miss index and multiple index accurately for multi-channel precision rapeseed drill, a multi-channel seeding performance detection system has been developed based on seeding time intervals. The system consists of a host computer (industry touch panel computer) and a slave computer (MSP430 MCU) the two-level system. Under the control of the host computer, the slave computer is in charge of collecting the seeding signals produced by a fiber-optic sensor through the time capture interrupts and collecting rotation speed signals produced by a photoelectric sensor through the external interrupt and timer interrupt. These signals were converted into seeding time-interval sequence and rotation-speed sequence respectively. Then the slave computer transmits the sequences to the host computer through the serial port with one designed transmission protocol. The host computer analyzes the sequences and computes the seeding performance indexes such as normal index, miss index and multiple index. On one hand, in order to verify the ability of multi-channel performance detection, tests were tried out by a series of given sequences by plates with different teeth and spacing angles. Seven different of type-A plates with uneven teeth and spacing angles were designed for different and random seeding performance by the fiber-optic sensor producing high and low electrical levels which were converted time-interval sequence by MCU's Time-Capture Interrupt. Type-B plate with 25 even teeth and

  5. Multi-channel electrical impedance tomography for regional tissue hydration monitoring.

    Science.gov (United States)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-06-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical

  6. Multi Channel Σ∆ A/D Converter for Integrated Power Meter

    Directory of Open Access Journals (Sweden)

    Dejan D. Mirković

    2010-06-01

    Full Text Available This paper describes three architectures for multi-channel sigma-delta ADC IC design. The proposed solution is aimed for the front-end of a three-phase integrated power meter. The pervious version of the power meter is to be redesigned by substituting six ADCs with two: one for converting currents and another for converting voltages in the three-phase power system. Therefore one pair of analog 3-to-1 multiplexers precedes ADCs. Discussion of advantages and drawbacks of the proposed solutions is illustrated by simulations using ADMS simulator that is a part of Mentor Graphics design kit.

  7. A Conflict Avoidance Data Allocation Algorithm in a Multi-channel Broadcast Environment

    Directory of Open Access Journals (Sweden)

    Kai Liu

    2010-03-01

    Full Text Available On-demand broadcast is an effective data dissemination approach in mobile computing. Recently, a large number of applications have been developed in broadcast systems equipped with multiple channels. In this study, we investigate the data scheduling issues arising in multi-channel on-demand broadcast. The bandwidth utilization problem, which renders a poor performance of existing algorithms, is explored and examined. To tackle the observed problem, a novel scheduling algorithm is proposed, which aims at avoiding the conflict in data allocation and therewith, improving the bandwidth utilization. Results from our simulation study demonstrate the superiority of the proposed algorithm.

  8. Comparison of planform multi-channel network characteristics of alluvial and bedrock constrained large rivers

    Science.gov (United States)

    Carling, P. A.; Meshkova, L.; Robinson, R. A.

    2011-12-01

    The Mekong River in northern Cambodia is an multi-channel mixed bedrock-alluvial river but it was poorly researched until present. Preliminary study of the Mekong geomorphology was conducted by gathering existing knowledge of its geological and tectonic settings, specific riparian vegetation and ancient alluvial terraces in which the river has incised since the Holocene. Altogether this process has allowed a geomorphological portrait of the river to be composed within the Quaternary context. Following this outline, the planform characteristics of the Mekong River network are compared, using analysis of channel network and islands configurations, with the fluvial patterns of the Orange River (South Africa), Upper Columbia River (Canada) and the Ganga River (India, Bangladesh). These rivers are selected as examples of multi-channel mixed bedrock alluvial, anastomosed alluvial and braided alluvial rivers respectively. Network parameters such as channel bifurcation angles asymmetry, sinuosity, braid intensity and island morphometric shape metrics are compared and contrasted between bedrock and alluvial systems. In addition, regional and local topographic trend surfaces produced for each river planform help explain the local changes in river direction and the degree of anastomosis, and distinguish the bedrock-alluvial rivers from the alluvial rivers. Variations between planform characteristics are to be explained by channel forming processes and in the case of mixed bedrock-alluvial rivers mediated by structural control. Channel metrics (derived at the reach-scale) provide some discrimination between different multi-channel patterns but are not always robust when considered singly. In contrast, island shape metrics (obtained at subreach-scale) allow robust discrimination between alluvial and bedrock systems.

  9. Efficient sequential compression of multi-channel biomedical signals.

    Science.gov (United States)

    Capurro, Ignacio; Lecumberry, Federico; Martin, Alvaro; Ramirez, Ignacio; Rovira, Eugenio; Seroussi, Gadiel

    2016-06-21

    This work proposes lossless and near-lossless compression algorithms for multi-channel biomedical signals. The algorithms are sequential and efficient, which makes them suitable for low-latency and low-power signal transmission applications. We make use of information theory and signal processing tools (such as universal coding, universal prediction, and fast online implementations of multivariate recursive least squares), combined with simple methods to exploit spatial as well as temporal redundancies typically present in biomedical signals. The algorithms are tested with publicly available electroencephalogram and electrocardiogram databases, surpassing in all cases the current state of the art in near-lossless and lossless compression ratios.

  10. A Multi-channel AC Power Supply Controller

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A multi-channel AC power Supply controler developed recently by us was introdueed briefty in this paper.This controller is a computer controlled multi-electronic-switch device.The controller contains 16 independent channels in a standard box(440W×405D×125H mm).There is an electronic switch in each channel,the rated load power is≤1 kW.The main function of the controller is to set the state of electronic switch(ON/OFF)

  11. A novel framework of multi-channel acoustic echo cancellation

    Institute of Scientific and Technical Information of China (English)

    HE Zhaoshui; XIE Shengli; FU Yuli

    2006-01-01

    Conventionally, multi-channel acoustic echo cancellation (AEC) achieves the goal by estimating the impulse responses of the local room. However, generally, conventional AEC methods have no unique solutions. Due to the strong correlation of the input signals, conventional methods are with many disadvantages. To overcome this problem, a new framework is proposed in this paper based on SIMO(single input multiple output) blind deconvolution. Under the new framework, we achieve the goal by identifying the impulse responses of distant room and avoiding the disadvantages of the conventional methods.

  12. A Multi-Channel Setup to Study Fractures in Scintillators

    CERN Document Server

    Tantot, A; Briche, R; Lefèvre, G; Manier, B; Zaïm, N; Deschanel, S; Vanel, L; Di Stefano, P C F

    2016-01-01

    To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the acoustic emission. Emitted visible light is recorded with nanosecond resolution, and crack propagation is monitored using infrared lighting and camera. An example of application to Bi4Ge3O12 (BGO) is provided.

  13. A multi-channel setup to study fractures in scintillators

    Science.gov (United States)

    Tantot, A.; Bouard, C.; Briche, R.; Lefèvre, G.; Manier, B.; Zaïm, N.; Deschanel, S.; Vanel, L.; Di Stefano, P. C. F.

    2016-12-01

    To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the acoustic emission. Emitted visible light is recorded with nanosecond resolution, and crack propagation is monitored using infrared lighting and camera. An example of application to \\text{B}{{\\text{i}}4}\\text{G}{{\\text{e}}3}{{\\text{O}}12} (BGO) is provided.

  14. Dust and Smoke Detection for Multi-Channel Imagers

    Directory of Open Access Journals (Sweden)

    Wei Guo

    2010-10-01

    Full Text Available A detection algorithm of dust and smoke for application to satellite multi-channel imagers is introduced in this paper. The algorithm is simple and solely based on spectral and spatial threshold tests along with some uniformity texture. Detailed examinations of the threshold tests are performed along with explanations of the physical basis. The detection is performed efficiently at the pixel level and output is in the form of an index (or flag: 0 (no dust/smoke and 1 (dust/smoke. The detection algorithm is implemented sequentially and designed to run on segments of data instead of pixel by pixel for efficient processing. MODIS observations are used to test the operation and performance of the algorithm. The algorithm can capture heavy dust and smoke plumes very well over both land and ocean and therefore is used as a global detection algorithm. The method can be applied to any multi-channel imagers with channels at (or close to 0.47, 0.64, 0.86, 1.38, 2.26, 3.9, 11.0, 12.0 μm (such as current EOS/MODIS and future JPSS/VIIRS and GOES-R/ABI for the detection of dust and smoke. It can be used to operationally monitor the outbreak and dispersion of dust storms and smoke plumes that are potentially hazardous to our environment and impact climate.

  15. A duple watermarking strategy for multi-channel quantum images

    Science.gov (United States)

    Yan, Fei; Iliyasu, Abdullah M.; Sun, Bo; Venegas-Andraca, Salvador E.; Dong, Fangyan; Hirota, Kaoru

    2015-05-01

    Utilizing a stockpile of efficient transformations consisting of channel of interest, channel swapping, and quantum Fourier transforms, a duple watermarking strategy on multi-channel quantum images is proposed. It embeds the watermark image both into the spatial domain and the frequency domain of the multi-channel quantum carrier image, while also providing a quantum measurement-based algorithm to generate an unknown key that is used to protect the color information, which accompanies another key that is mainly used to scramble the spatial content of the watermark image in order to further safeguard the copyright of the carrier image. Simulation-based experiments using a watermark logo and nine building images as watermark image and carrier images, respectively, offer a duple protection for the copyright of carrier images in terms of the visible quality of the watermarked images. The proposed stratagem advances available literature in the quantum watermarking research field and sets the stage for the applications aimed at quantum data protection.

  16. Simulation of vibration control based on the multi-channel self-adaptive feed forward law for the floating raft system with AVAs%带主动动力吸振器的浮筏隔振系统自适应控制仿真分析

    Institute of Scientific and Technical Information of China (English)

    敬刘凯; 吴文伟; 翁震平

    2014-01-01

    文章针对浮筏隔振系统低频线谱噪声,设计了基于x-LMS算法的自适应前馈控制律的主动吸振控制方案,采用导纳综合方法仿真分析了浮筏隔振系统在多通道主动动力吸振装置作用下的振动控制效果。仿真结果表明,带主动动力吸振器的浮筏隔振系统对低频线谱振动有着较好的控制效果。%To improve the isolation performance of the conventional floating raft system, active dynamic vi-bration absorbers (AVAs) were applied, and an evaluation function about reducing the sum of mean square error of vibration response of four observation points which were located on the flexible foundation of float-ing raft system with AVAs was formatted. With this objective function and based on filtered x-LMS algo-rithm, the multi-channel self-adaptive feed forward law for the floating raft system with AVAs was designed and simulated. The simulation result shows that it is effective to use the floating raft system with AVAs for reducing the vibration of mechanical device at low frequency.

  17. Multi-channel quantum dragons from rectangular nanotubes with even-odd structure

    Science.gov (United States)

    Inkoom, Godfred; Novotny, Mark

    Recently, a large class of nanostructures called quantum dragons have been discovered theoretically. Quantum dragons are nanostuctures with correlated disorder but have an electron transmission probability  (E) =1 for all energies E when connected to idealized leads. Hence for a single channel, the electrical conductance for a two-probe measurement should give the quantum of conductance Go =2e2/h . The time independent Schrödinger equation for the single band tight binding model is solved exactly to obtain  (E) . We have generalized the matrix method and the mapping methods of in order to study multi-channel quantum dragons for rectangular nanotubes with even-odd structure. The studies may be relevant for experimental rectangular nanotubes, such as MgO, copper phthalocyanine or some types of graphyne.. Supported in part by NSF Grant DMR-1206233.

  18. Design and Analysis of Microstrip Multi-Channeled Filter Using Photonic Crystal Branchy Defect

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A multi-channeled filter based on branchy defect in a microstrip photonic crystal was proposed. By introducing a branchy structure across the defect region, multiple defect modes will appear inside the photonic gap, leading to the multi-channeled filtering phenomenon. In comparison with the conventional multi-channeled filters, the proposed structure is more compact and tunable as far as the device volume and fabrication are concerned. The microwave experiment results are found in agreement with simulation results.

  19. Compensation of multi-channel mismatches in high-speed high-resolution photonic analog-to-digital converter.

    Science.gov (United States)

    Yang, Guang; Zou, Weiwen; Yu, Lei; Wu, Kan; Chen, Jianping

    2016-10-17

    We demonstrate a method to compensate multi-channel mismatches that intrinsically exist in a photonic analog-to-digital converter (ADC) system. This system, nominated time-wavelength interleaved photonic ADC (TWI-PADC), is time-interleaved via wavelength demultiplexing/multiplexing before photonic sampling, wavelength demultiplexing channelization, and electronic quantization. Mismatches among multiple channels are estimated in frequency domain and hardware adjustment are used to approach the device-limited accuracy. A multi-channel mismatch compensation algorithm, inspired from the time-interleaved electronic ADC, is developed to effectively improve the performance of TWI-PADC. In the experiment, we configure out a 4-channel TWI-PADC system with 40 GS/s sampling rate based on a 10-GHz actively mode-locked fiber laser. After multi-channel mismatch compensation, the effective number of bit (ENOB) of the 40-GS/s TWI-PADC system is enhanced from ~6 bits to >8.5 bits when the RF frequency is within 0.1-3.1 GHz and from ~6 bits to >7.5 bits within 3.1-12.1 GHz. The enhanced performance of the TWI-PADC system approaches the limitation determined by the timing jitter and noise.

  20. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Directory of Open Access Journals (Sweden)

    Ying-Lun Chen

    2015-08-01

    Full Text Available A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO, and the feature extraction is carried out by the generalized Hebbian algorithm (GHA. To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  1. Multi-channel temperature measurement amplification system. [solar heating systems

    Science.gov (United States)

    Currie, J. R. (Inventor)

    1981-01-01

    A number of differential outputs of thermocouples are sequentially amplified by a common amplifier. The amplified outputs are compared with a reference temperature signal in an offset correction amplifier, and a particularly poled output signal is provided when a differential output is of a discrete level compared with a reference temperature signal.

  2. Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed.

    Science.gov (United States)

    Brüser, Christoph; Kerekes, Anna; Winter, Stefan; Leonhardt, Steffen

    2012-01-01

    Our work covers improvements in sensors and signal processing for unobtrusive, long-term monitoring of cardiac (and respiratory) rhythms using only non-invasive vibration sensors. We describe a system for the unobtrusive monitoring of vital signs by means of an array of novel optical ballistocardiography (BCG) sensors placed underneath a regular bed mattress. Furthermore, we analyze the systems spatial sensitivity and present proof-of-concept results comparing our system to a more conventional BCG system based on a single electromechanical-film (EMFi) sensor. Our preliminary results suggest that the proposed optical multi-channel system could have the potential to reduce beat-to-beat heart rate estimation errors, as well as enable the analysis of more complex breathing patterns.

  3. [Development of multi-channels cardiac electrophysiological polygraph with LabVIEW as software platform and its clinical application].

    Science.gov (United States)

    Fan, Shounian; Jiang, Yi; Jiang, Chenxi; Yang, Tianhe; Zhang, Chengyun; Liu, Junshi; Wu, Qiang; Zheng, Yaxi; Liu, Xiaoqiao

    2004-10-01

    Polygraph has become a necessary instrument in interventional cardiology and fundamental research of medicine up to the present. In this study, a LabView development system (DS) (developed by NI in U.S.) used as software platform, a DAQ data acquisition module and universal computer used as hardware platform, were creatively coupled with our self-made low noise multi-channels preamplifier to develop Multi-channels electrocardiograph. The device possessed the functions such as real time display of physiological process, digit highpass and lowpass, 50Hz filtered and gain adjustment, instant storing, random playback and printing, and process control stimulation. Besides, it was small-sized, economically practical and easy to operate. It could advance the spread of cardiac intervention treatment in hospitals.

  4. Multi-channel detector readout method and integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Moses, William W.; Beuville, Eric; Pedrali-Noy, Marzio

    2004-05-18

    An integrated circuit which provides multi-channel detector readout from a detector array. The circuit receives multiple signals from the elements of a detector array and compares the sampled amplitudes of these signals against a noise-floor threshold and against one another. A digital signal is generated which corresponds to the location of the highest of these signal amplitudes which exceeds the noise floor threshold. The digital signal is received by a multiplexing circuit which outputs an analog signal corresponding the highest of the input signal amplitudes. In addition a digital control section provides for programmatic control of the multiplexer circuit, amplifier gain, amplifier reset, masking selection, and test circuit functionality on each input thereof.

  5. Multi-channel detector readout method and integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Moses, William W.; Beuville, Eric; Pedrali-Noy, Marzio

    2006-12-12

    An integrated circuit which provides multi-channel detector readout from a detector array. The circuit receives multiple signals from the elements of a detector array and compares the sampled amplitudes of these signals against a noise-floor threshold and against one another. A digital signal is generated which corresponds to the location of the highest of these signal amplitudes which exceeds the noise floor threshold. The digital signal is received by a multiplexing circuit which outputs an analog signal corresponding the highest of the input signal amplitudes. In addition a digital control section provides for programmatic control of the multiplexer circuit, amplifier gain, amplifier reset, masking selection, and test circuit functionality on each input thereof.

  6. Multi-channel Hybrid Access Femtocells: A Stochastic Geometric Analysis

    CERN Document Server

    Zhong, Yi

    2011-01-01

    For two-tier networks consisting of macrocells and femtocells, the channel access mechanism can be configured to be open access, closed access, or hybrid access. Hybrid access arises as a compromise between open and closed access mechanisms, in which a fraction of available spectrum resource is shared to nonsubscribers while the remaining reserved for subscribers. This paper focuses on a hybrid access mechanism for multi-channel femtocells which employ orthogonal spectrum access schemes. Considering a randomized channel assignment strategy, we analyze the performance in the downlink. Using stochastic geometry as technical tools, we derive the distributions of signal-to-interference-plus-noise ratios, and mean achievable rates, of both nonsubscribers and subscribers. The established expressions are amenable to numerical evaluation, and shed key insights into the performance tradeoff between subscribers and nonsubscribers. The analytical results are corroborated by numerical simulations.

  7. SYSTEMIC DISORDERS AFFECTING DENTAL PATHOLOGY

    OpenAIRE

    Knezevic R. Milan; Andjelic S. Gordana; Knezevic M. Milena

    2014-01-01

    A retrospective overview of systemic disorders which might be associated with dental pathology is made. They are grouped as follows: (a) congenital dental developmental disorders, (b) chromosomal anomalies, (c) radiations, (d) immune disorders, (e) intoxications, (f) neurological alterations, (g) gastrointestinal diseases, (h) osteodystrophy and associated conditions, (i) skin diseases, (j) metabolic and endocrine disorders, (k) craniofacial malformation syndromes and other congenital g...

  8. Research on the method of multi-channel video acquisition and display based on FPGA

    Directory of Open Access Journals (Sweden)

    Jingbo Xia

    2010-11-01

    Full Text Available With the problems of high speed and asynchronism in a multi-channel video, a video monitor system based on FPGA and SRAM is designed and implemented. The system adopts the method of time-division multiplexing to realize the function of four-channel video parallel acquisition. The synchronization between four-channel video is achieved by using the field-selected algorithm. The four-channel video can be outputted to LCD with the technique of ping-pang cache. The LCD display sequences are generated by the finite state machine using Verilog HDL. The system is simple, flexible and with high-quality, and it has a broad application prospect.

  9. A high-throughput, multi-channel photon-counting detector with picosecond timing

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchanne...

  10. The use of service channels by citizens in the Netherlands: implications for multi-channel management

    NARCIS (Netherlands)

    Pieterson, Willem Jan; Ebbers, Wolfgang E.

    2008-01-01

    Many governmental organizations are changing their service channel management strategies to multi-channel management. However, very few empirical studies exist that explore how these multi-channel strategies should be shaped. In this article we test a number of hypotheses on citizens' channel use

  11. Multi-channel sampling theorems for band-limited signals with fractional Fourier transform

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Multi-channel sampling for band-limited signals is fundamental in the theory of multi-channel parallel A/D environment and multiplexing wireless communication environment. As the fractional Fourier transform has been found wide applications in signal processing fields, it is necessary to consider the multi-channel sampling theorem based on the fractional Fourier transform. In this paper, the multi-channel sampling theorem for the fractional band-limited signal is firstly proposed, which is the generalization of the well-known sampling theorem for the fractional Fourier transform. Since the periodic nonuniformly sampled signal in the fractional Fourier domain has valuable applications, the reconstruction expression for the periodic nonuniformly sampled signal has been then obtained by using the derived multi-channel sampling theorem and the specific space-shifting and phase-shifting properties of the fractional Fourier transform. Moreover, by designing different fractional Fourier filters, we can obtain reconstruction methods for other sampling strategies.

  12. Design of a multi-channel free space optical interconnec-tion component

    Institute of Scientific and Technical Information of China (English)

    JIA Da-gong; ZHANG Pei-song; JING Wen-cai; TAN Jun; ZHANG Hong-xia; ZHANG Yi-mo

    2008-01-01

    A multi-channel free space optical interconnection component, fiber optic rotary joint, was designed using a Dove prism.When the Dove prism is rotated an angle of α around the longitudinal axis, the image rotates an angle of 2α. The opticalinterconnection component consists of the signal transmission system, Dove prim and driving mechanism. The planetarygears are used to achieve the speed ratio of 2:1 between the total optical interconnection component and the Dove prism.The C-lenses are employed to couple different optical signals in the signal transmission system. The coupling loss betweenthe receiving fiber of stationary part and the transmitting fiber of rotary part is measured.

  13. A Restless Bandit Formulation of Multi-channel Opportunistic Access: Indexablity and Index Policy

    CERN Document Server

    Liu, Keqin

    2008-01-01

    We focus on an opportunistic communication system consisting of multiple independent channels with time-varying states. With limited sensing, a user can only sense and access a subset of channels and accrue rewards determined by the states of the sensed channels. We formulate the problem of optimal sequential channel selection as a restless multi-armed bandit process, for which a powerful index policy--Whittle's index policy--can be implemented based on the indexability of the system. Exploiting the underlying structure of the multi-channel opportunistic access problem, we establish the indexability and obtain Whittle's index in closed-form for both discounted reward and average reward criteria. These results lead to the direct implementation of Whittle's index policy with remarkably low complexity. Furthermore, we develop a simple approach to evaluate the optimal performance under a relaxed constraint on sensing actions, which provides an upper bound of the optimal performance of the original restless multi-...

  14. Signal Detection of Multi-Channel Capillary Electrophoresis Chip Based on CCD

    Science.gov (United States)

    Lv, Hongfeng; Yan, Weiping; Yang, Xiaobo; Li, Jiechao; Zhu, Jieying

    2012-12-01

    A kind of multi-channel capillary electrophoresis (CE) chip signal detection system based on CCD was developed. The output signal of the CCD sensor was processed by a series of pre-processing circuits and ADC, and then it was collected by the Field Programmable Gate Array (FPGA) chip which communicated with a host computer. The core in FPGA was designed to control the signal flow of the CCD and transfer the data to PC based on a Nios II embedded soft-processor. The application of PC was used to store the data and demonstrate the curve. The measurement of the fluorescent signals for different concentration Rhodamine B dyes is presented and the comparison with other detection systems is also discussed.

  15. The physics of disordered systems

    CERN Document Server

    Ray, Purusattam

    2012-01-01

    Disordered systems are ubiquitous in nature and their study remains a profound and challenging subject of current research. Ideas and methods from the physics of Disordered systems have been fruitfully applied to several fields ranging from computer science to neuroscience. This book contains a selection of lectures delivered at the 'SERC School on Disordered Systems', spanning topics from classic results to frontier areas of research in this field. Spin glasses, disordered Ising models, quantum disordered systems, structural glasses, dilute magnets, interfaces in random field systems and disordered vortex systems are among the topics discussed in the text, in chapters authored by active researchers in the field, including Bikas Chakrabarti, Arnab Das, Deepak Kumar, Gautam Menon, G. Ravikumar, Purusattam Ray, Srikanth Sastry and Prabodh Shukla. This book provides a gentle and comprehensive introduction to the physics of disordered systems and is aimed at graduate students and young scientists either working i...

  16. Design of multi-channel digital laser galvanometric control system based on CAN bus%控制局域网络多路数字化振镜控制系统设计

    Institute of Scientific and Technical Information of China (English)

    高燚; 卫建华; 邓云兵

    2015-01-01

    T raditional galvanometer control system uses three‐loop control of current‐speed‐po‐sition ,which has the complex circuit and low communication efficiency .Thus a multi‐channel digital galvanometer control system based on CAN was proposed .Firstly ,Simulink mathemat‐ical model of position loop control system w as established ,w hich is based on the principle of digital laser galvanometric control system .By analyzing the galvanometric motor control sys‐tem ,a closed loop control system of galvanometric motor and simulation experiment were pres‐ented .Then the communication protocol based on CAN bus and solftware flow of the control system were presented to realize a multi‐channel digital galvanometric control system .%针对传统振镜控制系统采用放大器实现电流—速度—位置三环控制,具有电路复杂、通信效率低等缺点,给出了一种控制局域网络(CAN)多路数字化振镜控制系统的设计方案。首先基于数字化振镜原理,建立振镜电机Simulink数字模型,然后通过分析振镜控制系统,设计振镜电机的闭环控制系统,随后给出了基于CAN数据总线的通信协议及控制系统的软件流程,实现了多路数字化振镜控制系统。

  17. Multi-channel Virtual Instrument OscilloScope for Servo Motor Debugging System%多通道虚拟示波器伺服电机调试系统

    Institute of Scientific and Technical Information of China (English)

    张超; 游林儒

    2012-01-01

    Virtual instrument technology for servo motor debugging system was introduced. RS - 485 bus was chosen for the data transmission channel according to the system's real-time requirements,which send the voltage,current,speed collected by the microcontroller and the related parameters during the process of servo control to the PC. The PC used LabVIEW programming, which can implement the functions of data collection, processing, display and storage, and realize the on-line monitoring of servo motor control system. Experimental results show that the system can meet the requirements with desired technical targets.%介绍了虚拟仪器技术在伺服电机调试系统中的应用.根据系统实时性要求,采用基于RS - 485总线的数据传输通适,通过串行接口将微控制器采集到的电压、电流、转速及伺服控制过程中的相关参数传送到上位机.上位机采用LabVIEW编程,完成数据的采集、处理、显示和存储,实现对伺服电机控制系统运行状态的在线监控.实验证明,该系统达到了预期的技术要求.

  18. 基于FPGA的多路数据采集与传输系统设计%Design of Multi-Channel Data Acquisition and Transmission System Based on FPGA

    Institute of Scientific and Technical Information of China (English)

    李华; 刘宝盈; 刘萌; 谢谦

    2014-01-01

    In order to acquire 8 signals and transmit them to the application system accurately,this paper presents an improved FPGA combined with ADC and CAN bus based data acquisition and transmission system. Firstly,AD is controlled by FPGA to acquire 8 analog signals and convert them to one bit digital signal which is sent to FPGA.Then the serial-to-parallel operation and data reconstruction was used to process the one bit signal.At last,the signal was transmitted to application via the CAN bus system.Experimental results proved,when the conversion rate of ADC128 is 50kSPS,the system can work normally.The system has advantages of reliable and steady function,strong real-time and good universality.%为了准确采集8路数据并稳定传输给应用系统,文章设计了一套基于FPGA结合ADC和CAN总线的数据采集与传输系统。首先,AD在FPGA的控制下将8路模拟信号采集并以一位数字信号的形式输出给FPGA,然后经过串并转换与数据重组,最后通过CAN总线传输给应用系统。实验结果表明,AD以50KSPS采集数据时,系统工作正常。整个系统性能稳定可靠、实时性强,具有较好的通用性。

  19. A Class of Multi-Channel Cosine Modulated IIR Filter Banks

    CERN Document Server

    Vanka, Sundaram; Prabhu, K M M; Aravind, R

    2007-01-01

    This paper presents a class of multi-channel cosine-modulated filter banks satisfying the perfect reconstruction (PR) property using an IIR prototype filter. By imposing a suitable structure on the polyphase filter coefficients, we show that it is possible to greatly simplify the PR condition, while preserving the causality and stability of the system. We derive closed-form expressions for the synthesis filters and also study the numerical stability of the filter bank using frame theoretic bounds. Further, we show that it is possible to implement this filter bank with much lower number of arithmetic operations when compared to FIR filter banks with comparable performance. The filter bank's modular structure also lends itself to efficient VLSI implementation.

  20. Generalized L\\"uscher Formula in Multi-channel Baryon-Meson Scattering

    CERN Document Server

    Li, Ning

    2012-01-01

    L\\"uscher's formula relates the elastic scattering phase shifts to the two-particle energy levels in a finite cubic box. The original formula was obtained for elastic scattering of two massive spinless particles in the center of mass frame. In this paper, we consider the case for the scattering of a spin 1/2 particle with a spinless particle in multi-channel scattering. A generalized relation between the energy of two particle system and the scattering matrix elements is established. We first obtain this relation using quantum-mechanics in both center-of-mass frame and in a general moving frame. The result is then generalized to quantum field theory using methods outlined in Ref. \\cite{Hansen:2012tf}. We verify that the results obtained using both methods are equivalent up to terms that are exponentially suppressed in the box size.

  1. A method of multi-channel reference signals acquiring in broadband ANC

    Institute of Scientific and Technical Information of China (English)

    MA Ling-kun; HUANG Jian-guo; ZHANG Li-jie

    2008-01-01

    In a flank array on an unmanned underwater vehicle (UUV), self-generated noise which has broadband and colored spectrum property in frequency and spatial domain is the main factor affecting the performance of weak signal detection, so the technique of adaptive noise cancellation (ANC) as well as physical denoising and active noise cancellation are often used in practice. Because ANC is based on correlations, improvements in performance come from better correlation between reference signals and primary signals. Taking full advantage of the characteristics of flank arrays and the characteristics of information obtained from hydrophones, a new method for reference signal acquisition for adaptive noisecancellation is proposed, in which the multi-channel reference signals are obtained by accurate delaying for a given direction of arrival (DOA) and differencing between adjacent outputs of array elements. The validity of the proposed method was verified through system modeling simulations and lake experiments which showed good performance with little additional computational burden.

  2. A customizable multi-channel loudness compensation method based on WDRC for digital hearing aids

    Science.gov (United States)

    Hu, Jiebin; Wang, Mingjiang; Ma, Min

    2017-08-01

    Loudness compensation is the most significant signal processing algorithm in digital hearing aids at present. An algorithm of multi-channel loudness compensation for embedded system has been put forward in this paper. The number of channels is customizable in this algorithm. The algorithm can set different number and different width of channels for each patient based on frequency domain wide dynamic range compression. First, according to the requirement of patient to divide the frequency domain into multiple unequal frequency bands. And then calculate the gain of each channel according to the input-output curve of sound pressure level. Finally, the time-domain impulse response of gain is computed from Mel filter banks. It is used in conjunction with speech enhancement processing in hearing aids. Simulation results show that the algorithm can effectively enhance the loudness for different frequencies.

  3. The use of multi-channel ground penetrating radar and stream monitoring to investigate the seasonal evolution of englacial and subglacial drainage systems at the terminus of Exit Glacier, Alaska

    Science.gov (United States)

    Kilgore, Susan Marlena

    Concerns regarding the issue of climate change and, in particular, the rapid retreat of glaciers around the world, have placed great importance on glacial monitoring. Some of the methods most commonly used to observe glacial change---direct mass balance measurements and remote sensing---provide valuable information about glacier change. However, these methods do not address the englacial and subglacial environments. Surface meltwater that enters englacial and subglacial hydrological networks can contribute to acceleration of ice flow, increased calving on marine-terminating glaciers, surges or outburst floods, and greater overall ablation rates. Because subsurface drainage systems often freeze during the winter and re-form each summer, examining the seasonal evolution of these networks is crucial for assessing the impact that internal drainage may have on the behavior of a glacier each year. The goal of this study is to determine the role englacial and subglacial drainage system evolution plays in influencing summer ablation and discharge at the terminus of Exit Glacier, a small valley glacier located in South-central Alaska. During the summers of 2010 and 2011, we used ground-penetrating radar (GPR) to locate internal drainage features on the lower 100 meters of the glacier. GPR surveys were conducted in June and August of each year in an effort to observe the evolution of the drainage systems over the course of an ablation season. Three antenna frequencies---250, 500, and 800 MHz---were used on a dual frequency GPR so that various resolutions and depths in the ice could be viewed simultaneously. Stream monitoring was conducted to document discharge in the proglacial stream throughout the 2011 season. These data were compared with weather records to differentiate noticeable meltwater releases from precipitation events. Additionally, morphological changes in the glacier were observed through photographic documentation. Throughout the observation period, significant

  4. Design of Multi-Channel Synchronized Photoelectric Acquisition System Based on PSD Sensor and FPGA%基于FPGA的PSD多路光电数据采集系统设计

    Institute of Scientific and Technical Information of China (English)

    杨海马; 傅思勇; 王建宇; 胡以华; 刘瑾

    2012-01-01

    A photoelectric data acquisition system was designed. The master chip used EP2C8Q208C8 and the analog-to-digital chip was AD73360. When photo-currents emerged from a 2D-PSD sensor .these multichannel signals were changed into voltages. Then these voltages were converted to 16-bit datum by AD73360. All data operated by FPGA,the position of the incidence ray point on the 2D-PSD will be achieved. After analyzing the result of experiment, the whole system is capable of 4-route synchronized acquisition,64 kHz max sampling, 12-bit real precision and 16-bit resolution. The real resolution of ray point on the PSD is 10 μm, and the time response is less than 5 ms. This system is suit to the application of high-speed, synchronized photoelectric detection or other fields that need data acquisition.%以EP2C8Q208C8为主控芯片,利用AD73360进行多路、同步模数转换,对两维PSD传感器信号进行数据采集,实现高精度的多路光电数据采集系统设计.通过硬件编程,系统能够实现4路、64kHz、12位有效数据位、16位分辨率的光电信号获取,经FPGA运算后实时输出入射光位置,完成光电位置探测功能.试验数据表明:系统位置探测分辨率优于10 μm,系统响应时间小于5 ms,适用于快速、同步光电信号获取设计中,为有类似需求的PSD后续处理电路应用提供了一种可供借鉴的技术参考.

  5. Design of Embedded Communication System Between Multi-Channel UART And Ethernet Based on RL-ARM Library%基于RL-ARM的嵌入式以太网与串口通信系统设计

    Institute of Scientific and Technical Information of China (English)

    邓红德; 李阳; 吴佳楠

    2012-01-01

    According to the demand for expanding UART interfaces in simulation experiment of UAV flight control system, the communication between four UART interfaces and Ethernet is accomplished based on LPC1768 host processor, and receiving function contains three intelligent communication modes, which is frame head and frame length mode, frame head and frame tail mode and frame length and frame tail mode. The design of software implements UDP communication in RL-ARM real time library. The result indicates that the system not only has the feature of real-time communication of serial port, but also low-cost implemention and steady operation of Ethernet.%针对无人机飞控系统半物理仿真实验中需要对串口进行扩展的问题,系统采用主控制器LPC1768设计了基于以太网方式的串口扩展,完成了4个串口与以太网之间的双向通信,且串口接收支持帧头+帧长、帧头+帧尾和帧长+帧尾3神智能通信方式.软件设计中利用RL-ARM实时库实现了与PC之间的UDP协议通信.结果表明,采用此方案可以使系统具有实时、可靠和成本低的特点.

  6. High transformer ratio of multi-channel dielectric wakefield structures

    Science.gov (United States)

    Shchelkunov, Sergey V.; Marshall, Thomas C.; Sotnikov, Gennadij V.; Hirshfield, Jay L.

    2016-09-01

    Dielectric wakefield (DWA) accelerator concepts are receiving attention on account of their promising performance, mechanical simplicity, and anticipated low cost. Interest in DWA physics directed toward an advanced high-gradient accelerator has been enhanced by a finding that some dielectrics can withstand very high fields (>1 GV/m) for the short times during the passage of charged bunches along dielectric-lined channels. In a two-channel structure, a drive bunch train propagates in a first channel, and in the second adjacent channel where a high gradient wakefield develops, a witness bunch is accelerated. Compared with single-channel DWA's, a two-beam accelerator delivers a high transformer ratio, and thereby reduces the number of drive beam sections needed to achieve a given final test beam energy. An overview of multi-channel DWA structures will be given, with an emphasis on two-channel structures, presenting their advantages and drawbacks, and potential impact on the field. Studies aimed to examine charging rate and charge distribution in a thin walled dielectric wakefield accelerator from a passing charge bunch and the physics of conductivity and discharge phenomena in dielectric materials useful for such accelerator applications are presented in a separate paper in the EAAC-2015 conference proceedings.

  7. High transformer ratio of multi-channel dielectric wakefield structures

    Energy Technology Data Exchange (ETDEWEB)

    Shchelkunov, Sergey V., E-mail: sergey.shchelkunov@gmail.com [Omega-P R& D, Inc, CT 06511 (United States); Yale University, CT (United States); Marshall, Thomas C. [Omega-P R& D, Inc, CT 06511 (United States); Sotnikov, Gennadij V. [NSC Kharkov Institute of Physics and Technology, Kharkov (Ukraine); Hirshfield, Jay L. [Omega-P R& D, Inc, CT 06511 (United States)

    2016-09-01

    Dielectric wakefield (DWA) accelerator concepts are receiving attention on account of their promising performance, mechanical simplicity, and anticipated low cost. Interest in DWA physics directed toward an advanced high-gradient accelerator has been enhanced by a finding that some dielectrics can withstand very high fields (>1 GV/m) for the short times during the passage of charged bunches along dielectric-lined channels. In a two-channel structure, a drive bunch train propagates in a first channel, and in the second adjacent channel where a high gradient wakefield develops, a witness bunch is accelerated. Compared with single-channel DWA's, a two-beam accelerator delivers a high transformer ratio, and thereby reduces the number of drive beam sections needed to achieve a given final test beam energy. An overview of multi-channel DWA structures will be given, with an emphasis on two-channel structures, presenting their advantages and drawbacks, and potential impact on the field. Studies aimed to examine charging rate and charge distribution in a thin walled dielectric wakefield accelerator from a passing charge bunch and the physics of conductivity and discharge phenomena in dielectric materials useful for such accelerator applications are presented in a separate paper in the EAAC-2015 conference proceedings.

  8. Mathematical Model of the Multi-Channel Spiral Cyclone

    Directory of Open Access Journals (Sweden)

    Justina Danilenkaitė

    2013-12-01

    Full Text Available The article deals with a problem of experimental investigation and numerical simulation of gas aerodynamics of a multi-channel spiral cyclone with a tangential inlet. The paper presents an overview of experimental and theoretical works on the cyclones having a particularly complex turbulent flow and focuses on three-dimensional transport differential equations for a non-compressible laminar and turbulent flow inside the cyclone. The equations have been solved applying the numerical finite volume method using the RNG (Re–Normalisation Group k-ε turbulence model. The numerical simulation of the flow cyclone has been carried out. The height of the cyclone is 0.80 m with 0.33 m in diameter, the height of the spiral–cylindrical part – 0.098 meters and that of the cone – 0.45 m. Inlet dimensions (cylindrical part on the side, in accordance with drawings makes a×b = 28×95 mm. The mathematical model for the air traffic movement cyclone has accounted for Navier-Stokes (Reynolds three-dimensional differential equations. The simulation results have been obtained with reference to the cyclone of tangential velocity profiles using RNG k-ε turbulence model. The inlet velocity of 5.1 m/s slightly differs from experimental results, thus making an error of 7%.Article in Lithuanian

  9. Multi-Channel Transfer Function with Dimensionality Reduction

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P.; Cone, Angela C.; Sosinsky, Gina E.; Martone, Maryann E.

    2010-01-01

    The design of transfer functions for volume rendering is a difficult task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel. In this paper, we propose a new method for transfer function design. Our new method provides a framework to combine multiple approaches and pushes the boundary of gradient-based transfer functions to multiple channels, while still keeping the dimensionality of transfer functions to a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. The high-dimensional data of the domain is reduced by applying recently developed nonlinear dimensionality reduction algorithms. In this paper, we used Isomap as well as a traditional algorithm, Principle Component Analysis (PCA). Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. In this publication we report on the impact of the dimensionality reduction algorithms on transfer function design for confocal microscopy data. PMID:20582228

  10. A Comparative Evaluation of Humphrey Perimetry and the Multi-channel Pattern Visual Evoked Potentials

    Institute of Scientific and Technical Information of China (English)

    Caiping Hu; Lezheng Wu; De-Zheng Wu; Shixian Long

    2000-01-01

    Purposes: To compare the multi-channel pattern visual evoked potentials to Humphrey perimetry in the assessment of central visual function in primary open angle glaucoma.Methods: The multi-channel checkerboard reversal PVEPs waves to full-field and half-field stimulus of 25 normal persons and 74 patients with primary open angle glaucoma were recorded and analyzed, All patients were examined using Humphrey Field Analyzer. The area of visual field corresponding to the area of retina stimulated during multi-channel PVEPs testing were analysed, straight-line correlation and regression analyses of the various multi-channel PVEPs parameters and the total dB losses were performed.Results: The multi-channel PVEPs demonstrated a low detection rate compared with Humprey perimetry in the early glaucoma, absolute latency and field loss were correlated in the late stage of glaucoma, and absolute amplitude and field loss were not correlated.Conclusions: In relation to signalling “early” loss the multi-channel PVEPs was inferior to Humphrey perimetry, in late loss of primary open angle glaucoma, multi-channel PVEPs can provide a valuable, objective complement to Humphrey perimetry.

  11. Automated mitosis detection in histopathology using morphological and multi-channel statistics features.

    Science.gov (United States)

    Irshad, Humayun

    2013-01-01

    According to Nottingham grading system, mitosis count plays a critical role in cancer diagnosis and grading. Manual counting of mitosis is tedious and subject to considerable inter- and intra-reader variations. The aim is to improve the accuracy of mitosis detection by selecting the color channels that better capture the statistical and morphological features, which classify mitosis from other objects. We propose a framework that includes comprehensive analysis of statistics and morphological features in selected channels of various color spaces that assist pathologists in mitosis detection. In candidate detection phase, we perform Laplacian of Gaussian, thresholding, morphology and active contour model on blue-ratio image to detect and segment candidates. In candidate classification phase, we extract a total of 143 features including morphological, first order and second order (texture) statistics features for each candidate in selected channels and finally classify using decision tree classifier. The proposed method has been evaluated on Mitosis Detection in Breast Cancer Histological Images (MITOS) dataset provided for an International Conference on Pattern Recognition 2012 contest and achieved 74% and 71% detection rate, 70% and 56% precision and 72% and 63% F-Measure on Aperio and Hamamatsu images, respectively. The proposed multi-channel features computation scheme uses fixed image scale and extracts nuclei features in selected channels of various color spaces. This simple but robust model has proven to be highly efficient in capturing multi-channels statistical features for mitosis detection, during the MITOS international benchmark. Indeed, the mitosis detection of critical importance in cancer diagnosis is a very challenging visual task. In future work, we plan to use color deconvolution as preprocessing and Hough transform or local extrema based candidate detection in order to reduce the number of candidates in mitosis and non-mitosis classes.

  12. Multi-channel and sharp angular spatial filters based on one-dimensional photonic crystals

    Institute of Scientific and Technical Information of China (English)

    Shaoji Jiang; Jianrong Li; Jijia Tang; Hezhou Wang

    2006-01-01

    A photonic heterostructure with multi-channel and sharp angular defect modes by combining two different one-dimensional defective photonic crystals is proposed. The filters designed on the basis of this heterostructure possess both functions of multi-channel narrow band filtering and sharp angular filtering.The channels, channel interval, and number of channels can be tuned by adjusting the geometric and physical parameters of the heterostuctures. This kind of filters will benefit the development of multi-channel interstellar or atmosphere optical communication.

  13. Systemic disorders affecting dental pathology

    Directory of Open Access Journals (Sweden)

    Knežević Milan R

    2014-12-01

    Full Text Available A retrospective overview of systemic disorders which might be associated with dental pathology is made. They are grouped as follows: (a congenital dental developmental disorders, (b chromosomal anomalies, (c radiations, (d immune disorders, (e intoxications, (f neurological alterations, (g gastrointestinal diseases, (h osteodystrophy and associated conditions, (i skin diseases, (j metabolic and endocrine disorders, (k craniofacial malformation syndromes and other congenital general malformations. The associated dental pathology is described in each case.

  14. Moving Target Indication for Multi-channel Airborne Radar Systems

    NARCIS (Netherlands)

    Lidicky, L.

    2010-01-01

    Moving target indication (MTI) using radar is of great interest in civil and military applications. Its uses include airborne or space-borne surveillance of ground moving vehicles (cars, trains) or ships at sea, for instance. Airborne (space-borne) radar offers several advantages when compared to op

  15. Moving Target Indication for Multi-channel Airborne Radar Systems

    NARCIS (Netherlands)

    Lidicky, L.

    2010-01-01

    Moving target indication (MTI) using radar is of great interest in civil and military applications. Its uses include airborne or space-borne surveillance of ground moving vehicles (cars, trains) or ships at sea, for instance. Airborne (space-borne) radar offers several advantages when compared to op

  16. Consideration of conditions required for multi-channel simultaneous bioimpedance measurement

    OpenAIRE

    1998-01-01

    Impedance techniques have been widely applied to the biomedical engineering field. In order to obtain definite results from bioimpedance, multi-channel measurement is effective. A linearity of biological tissue and fundamental technical parameters for the instrument must be confirmed. In this study, the fundamental conditions have been investigated for multi-channel bioimpedance measurement and the condition of measurement for biological tissue has been confirmed. The differences of every mea...

  17. Accuracy Assessment for Multi-Channel ECG Waveforms Using Soft Computing Methodologies

    Directory of Open Access Journals (Sweden)

    Menta Srinivasulu

    2014-07-01

    Full Text Available ECG waveform rhythmic analysis is very important. In recent trends, analysis processes of ECG waveform applications are available in smart devices. Still, existing methods are not able to accomplish the complete accuracy assessment while classify the multi-channel ECG waveforms. In this paper, proposed analysis of accuracy assessment of the classification of multi-channel ECG waveforms using most popular Soft Computing algorithms. In this research, main focus is on the better rule generation to analyze the multi-channel ECG waveforms. Analysis is mainly done inSoft Computing methods like the Decision Trees with different pruning analysis, Logistic Model Trees with different regression process and Support Vector Machine with Particle Swarm Optimization (SVM-PSO. All these analysis methods are trained and tested with MIT-BIH 12 channel ECG waveforms. Before trained these methods, MSO-FIR filter should be used as data preprocessing for removal of noise from original multi-channel ECG waveforms. MSO technique is used for automatically finding out the cutoff frequency of multichannel ECG waveforms which is used in low-pass filtering process. The classification performance is discussed using mean squared error, member function, classification accuracy, complexity of design, and area under curve on MIT-BIH data. Additionally, this research work is extended for the samples of multi-channel ECG waveforms from the Scope diagnostic center, Hyderabad. Our study assets the best process using the Soft Computing methods for analysis of multi-channel ECG waveforms.

  18. Movement disorders in systemic diseases.

    Science.gov (United States)

    Poewe, Werner; Djamshidian-Tehrani, Atbin

    2015-02-01

    Movement disorders, classically involving dysfunction of the basal ganglia commonly occur in neurodegenerative and structural brain disorders. At times, however, movement disorders can be the initial manifestation of a systemic disease. In this article we discuss the most common movement disorders which may present in infectious, autoimmune, paraneoplastic, metabolic and endocrine diseases. Management often has to be multidisciplinary involving primary care physicians, neurologists, allied health professionals including nurses, occupational therapists and less frequently neurosurgeons. Recognizing and treating the underlying systemic disease is important in order to improve the neurological symptoms.

  19. Schizophrenia: A Systemic Disorder

    Science.gov (United States)

    Kirkpatrick, Brian; Miller, Brian; García-Rizo, Clemente; Fernandez-Egea, Emilio

    2015-01-01

    The concept of schizophrenia that is most widely taught is that it is a disorder in which psychotic symptoms are the main problem, and a dysregulation of dopamine signaling is the main feature of pathophysiology. However, this concept limits clinical assessment, the treatments offered to patients, research, and the development of therapeutics. A more appropriate conceptual model is that: 1) schizophrenia is not a psychotic disorder, but a disorder of essentially every brain function in which psychosis is present; 2) it is not a brain disease, but a disorder with impairments throughout the body; 3) for many patients, neuropsychiatric problems other than psychosis contribute more to impairment in function and quality of life than does psychosis; and, 4) some conditions that are considered to be comorbid are integral parts of the illness. In conclusion, students, patients, and family members should be taught this model, along with its implications for assessment, research, and therapeutics. PMID:23518782

  20. Schizophrenia: a systemic disorder.

    Science.gov (United States)

    Kirkpatrick, Brian; Miller, Brian; García-Rizo, Clemente; Fernandez-Egea, Emilio

    2014-07-01

    The concept of schizophrenia that is most widely taught is that it is a disorder in which psychotic symptoms are the main problem, and a dysregulation of dopamine signaling is the main feature of pathophysiology. However, this concept limits clinical assessment, the treatments offered to patients, research, and the development of therapeutics. A more appropriate conceptual model is that: 1) schizophrenia is not a psychotic disorder, but a disorder of essentially every brain function in which psychosis is present; 2) it is not a brain disease, but a disorder with impairments throughout the body; 3) for many patients, neuropsychiatric problems other than psychosis contribute more to impairment in function and quality of life than does psychosis; and, 4) some conditions that are considered to be comorbid are integral parts of the illness. In conclusion, students, patients, and family members should be taught this model, along with its implications for assessment, research, and therapeutics.

  1. A novel multi-channel quadrature Doppler backward scattering reflectometer on the HL-2A tokamak

    Science.gov (United States)

    Shi, Zhongbing; Zhong, Wulu; Jiang, Min; Yang, Zengchen; Zhang, Boyu; Shi, Peiwan; Chen, Wei; Wen, Jie; Chen, Chengyuan; Fu, Bingzhong; Liu, Zetian; Ding, Xuantong; Yang, Qingwei; Duan, Xuru

    2016-11-01

    A novel 16-channel fixed frequency Doppler backward scattering (DBS) reflectometer system has been developed on the HL-2A tokamak. This system is based on the filter-based feedback loop microwave source (FFLMS) technique, which has lower phase noise and lower power variation compared with present tunable frequency generation and comb frequency array generation techniques [J. C. Hillesheim et al. Rev. Sci. Instrum. 80, 083507 (2009) and W. A. Peebles et al. Rev. Sci. Instrum. 81, 10D902 (2010)]. The 16-channel DBS system is comprised of four × four-frequency microwave transmitters and direct quadrature demodulation receivers. The working frequencies are 17-24 GHz and 31-38 GHz with the frequency interval of 1 GHz. They are designed to measure the localized intermediate wave-number (k⊥ρ ˜ 1-2, k⊥ ˜ 2-9 cm-1) density fluctuations and the poloidal rotation velocity profile of turbulence. The details of the system design and laboratory tests are presented. Preliminary results of Doppler spectra measured by the multi-channel DBS reflectometer systems are obtained. The plasma rotation and turbulence distribution during supersonic molecular beam injection are analyzed.

  2. Holographic Conductivity in Disordered Systems

    CERN Document Server

    Ryu, Shinsei; Ugajin, Tomonori

    2011-01-01

    The main purpose of this paper is to holographically study the behavior of conductivity in 2+1 dimensional disordered systems. We analyze probe D-brane systems in AdS/CFT with random closed string and open string background fields. We give a prescription of calculating the DC conductivity holographically in disordered systems. In particular, we find an analytical formula of the conductivity in the presence of codimension one randomness. We also systematically study the AC conductivity in various probe brane setups without disorder and find analogues of Mott insulators.

  3. Application of multi-channel photoelastic imaging technology in array type ultrasonic nondestructive testing

    Science.gov (United States)

    Fan, Zhen-zhong; Bi, Chao

    2015-08-01

    With the rapid development of modern nondestructive testing technologies, ultrasonic phased array and Ultrasonic array testing technology has been used widely, at the same time the propagation process of ultrasonic in the material becomes more and more complex. In order to make the ultrasonic propagation path become visible and researchers can observe the acoustic field directly, considering the properties of the ultrasonic as a stress wave, according to the theory of polarized light interference, a multi-channel dynamic photoelastic imaging system is developed successfully. The system can generate many kinds of focusing ultrasonic fields in optical specimen by controlling the ultrasonic transmission delay time of each equipment channel, and the system has the ability to simulate the acoustic field's focusing process of the ultrasonic phased array. The image shot by CCD camera reflects the propagation process of the acoustic field in the specimen, and the dynamic video is formed under control of the timing circuit, and the system has the ability to save the captured image in the computer.

  4. Multi-channel monolithic integrated optic fiber Bragg grating sensor interrogator

    Science.gov (United States)

    Mendoza, Edgar A.; Esterkin, Yan; Kempen, Cornelia; Sun, Zongjian

    2011-09-01

    Fiber Bragg grating (FBG) is a mature sensing technology for the measurement of strain, vibration, acoustics, acceleration, pressure, temperature, moisture, and corrosion. It has gained rapid acceptance in civil, aerospace, chemical and petrochemical, medicine, aviation and automotive industries. The most prominent advantages of FBG are: small size and light weight, distributed array of FBG transducers on a single fiber, and immunity to radio frequency interference. However, a major disadvantage of FBG technology is that conventional state-of-the-art FBG interrogation system is typically bulky, heavy, and costly bench top instruments that are typically assembled from off-the-shelf fiber optic and optical components integrated with a signal electronics board into an instrument console. Based on the industrial need for a compact FBG interrogation system, this paper describes recent progress towards the development of miniature fiber Bragg grating sensor interrogator (FBG-Transceiver™) system based on multi-channel monolithic integrated optic sensor microchip technology. The integrated optic microchip technology enables monolithic integration of all functionalities, both passive and active, of conventional bench top FBG sensor interrogator system, packaged in a miniaturized, low power operation, 2 cm×5 cm small form factor (SFF) package suitable for long-term structural health monitoring in applications where size, weight, and power are critical for operation.

  5. Multi-channel Dual Clocks three-dimensional probability Random Multiple Access protocol for Wireless Public Bus Networks based on RTS/CTS mechanism

    Directory of Open Access Journals (Sweden)

    Zhou Sheng Jie

    2016-01-01

    Full Text Available A MAC protocol for public bus networks, called Bus MAC protocol, designed to provide high quality Internet service for bus passengers. The paper proposed a multi-channel dual clocks three-demission probability random multiple access protocol based on RTS/CTS mechanism, decreasing collisions caused by multiple access from multiple passengers. Use the RTS/CTS mechanism increases the reliability and stability of the system, reducing the collision possibility of the information packets to a certain extent, improves the channel utilization; use the multi-channel mechanism, not only enables the channel load balancing, but also solves the problem of the hidden terminal and exposed terminal. Use the dual clocks mechanism, reducing the system idle time. At last, the different selection of the three-dimensional probabilities can make the system throughput adapt to the network load which could realize the maximum of the system throughput.

  6. CMOS多通道芯片%CMOS Multi-Channel Chips

    Institute of Scientific and Technical Information of China (English)

    康凯; 高宗智

    2016-01-01

    In order to overcome a number of challenges in CMOS millimeter-wave integrated circuit design, the millimeter-wave device modeling, antenna design, circuit block, and multi-channel transceiver system are introduced in this paper. The equivalent-circuit models of millimeter-wave on-chip interconnected lines, multiple-coupled inductors, six-portM:N transformers, and the model of terahertz active device are studied and proposed, respectively. Moreover, a low noise amplifier with noise canceling and a power amplifier with a fully symmetrical distributed active transformer are introduced in this paper. Furthermore, the CMOS 60 GHz receiver with on-chip antenna and the multi-channel phase array transceiver are described, respectively.%针对互补金属氧化物半导体(CMOS)工艺在毫米波集成电路设计中存在的诸多挑战,分别从毫米波器件建模和天线设计,毫米波电路模块设计和多通道收发系统设计方面进行介绍,以克服相应挑战。该文研究和建立了毫米波频段片上互连线,耦合电感和六端口M:N变压器的等效模型和太赫兹有源器件模型,并对毫米波片上天线进行设计;介绍了基于噪声抵消的低噪声放大器电路和基于全对称平衡分布式有源变压器的功率放大器电路、毫米波移相器电路以及集成片上天线的CMOS 60 GHz接收机和多通道相控阵收发系统。

  7. Enabling Technology for the Exploration of the Arctic Ocean - Multi Channel Seismic Reflection data acquisition

    Science.gov (United States)

    Coakley, B.; Anderson, R.; Chayes, D. N.; Goemmer, S.; Oursler, M.

    2009-12-01

    Great advances in mapping the Arctic Ocean have recently been made through the relatively routine acquisition of multibeam data from icebreakers operating on various cruise. The USCGC Healy, the German icebreaker Polarstern, the Canadian icebreaker Amundsen and the Swedish icebreaker Oden all routinely collect multibeam data, even while in heavy ice pack. This increase in data has substantially improved our knowledge of the form of the Arctic Ocean seafloor. Unfortunately, it is not possible to routinely collect Multi Channel Seismic Reflection (MCS) data while underway in the ice pack. Our inability to simply collect these data restricts how we understand many of the features that segment the basin by depriving us of the historical information that can be obtained by imaging the stratigraphy. Without these data, scientific ocean drilling, the ultimate ground truth for Marine Geology, cannot be done. The technology and expertise to collect MCS must be adapted for the particular circumstances of the Arctic Ocean. While MCS data have been collected in the Arctic Ocean, the procedures have relied on icebreakers towing equipment. Since icebreakers follow the path of least resistance through the pack, data are acquired in locations that are not scientifically optimal and rarely in the relatively straight lines necessary for optimal processing. Towing in the ice pack is also difficult, inefficient and puts this equipment at substantial risk of crushing or loss. While icebreakers are one means to collect these data, it is time to conduct a systematic evaluation of the costs and benefits of different platforms for MCS data acquisition. This evaluation should enable collection of high-quality data set at selected locations to solve scientific problems. Substantial uncertainties exist about the relative capabilities, costs and limitations for acquisition of MCS data from various platforms in the Arctic Ocean. For example; - Is it possible to collect multi-channel seismic

  8. A Method of Multi-channel Data Acquisition with Adjustable Sampling Rate

    Directory of Open Access Journals (Sweden)

    Su Shujing

    2013-09-01

    Full Text Available Sampling rate of current signal acquisition systems are singular. Aiming at this shortcoming, a method of multi-channel data acquisition(DAQ with adjustable sampling rate is presented. The method realizes the cut-off frequency of anti-aliasing filter controlled by program with the help of switched-capacitor; by independently pulsing sampling signal of different ADCs, 16-channel sampling rate are adjustable within the range 50ksps, 25ksps, 10ksps, 5ksps, 1ksps. Theoretical analysis and experimental verification pointing at the proposed method are implemented: theoretical analysis shows that parameters of the filter meet the design requirements; experimental results show that cut-off frequency of the anti-aliasing filter matches variable sampling rate very well; choosing appropriate sampling rate according to the characteristics of the measured signal not only can well restore the measured signal, but also prevents system resources from waste. This method can meet needs of testing various signals with different frequency at the same time.  

  9. Block sparsity-based joint compressed sensing recovery of multi-channel ECG signals.

    Science.gov (United States)

    Singh, Anurag; Dandapat, Samarendra

    2017-04-01

    In recent years, compressed sensing (CS) has emerged as an effective alternative to conventional wavelet based data compression techniques. This is due to its simple and energy-efficient data reduction procedure, which makes it suitable for resource-constrained wireless body area network (WBAN)-enabled electrocardiogram (ECG) telemonitoring applications. Both spatial and temporal correlations exist simultaneously in multi-channel ECG (MECG) signals. Exploitation of both types of correlations is very important in CS-based ECG telemonitoring systems for better performance. However, most of the existing CS-based works exploit either of the correlations, which results in a suboptimal performance. In this work, within a CS framework, the authors propose to exploit both types of correlations simultaneously using a sparse Bayesian learning-based approach. A spatiotemporal sparse model is employed for joint compression/reconstruction of MECG signals. Discrete wavelets transform domain block sparsity of MECG signals is exploited for simultaneous reconstruction of all the channels. Performance evaluations using Physikalisch-Technische Bundesanstalt MECG diagnostic database show a significant gain in the diagnostic reconstruction quality of the MECG signals compared with the state-of-the art techniques at reduced number of measurements. Low measurement requirement may lead to significant savings in the energy-cost of the existing CS-based WBAN systems.

  10. The Time Division Multi-Channel Communication Model and the Correlative Protocol Based on Quantum Time Division Multi-Channel Communication

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-Hui; PEI Chang-Xing; NIE Min

    2010-01-01

    @@ Based on the classical time division multi-channel communication theory,we present a scheme of quantum time-division multi-channel communication(QTDMC).Moreover,the model of quantum time division switch(QTDS)and correlative protocol of QTDMC are proposed.The quantum bit error rate(QBER)is analyzed and the QBER simulation test is performed.The scheme shows that the QTDS can carry out multi-user communication through quantum channel,the QBER can also reach the reliability requirement of communication,and the protocol of QTDMC has high practicability and transplantable.The scheme of QTDS may play an important role in the establishment of quantum communication in a large scale in the future.

  11. Simultaneous Greedy Analysis Pursuit for compressive sensing of multi-channel ECG signals.

    Science.gov (United States)

    Avonds, Yurrit; Liu, Yipeng; Van Huffel, Sabine

    2014-01-01

    This paper addresses compressive sensing for multi-channel ECG. Compared to the traditional sparse signal recovery approach which decomposes the signal into the product of a dictionary and a sparse vector, the recently developed cosparse approach exploits sparsity of the product of an analysis matrix and the original signal. We apply the cosparse Greedy Analysis Pursuit (GAP) algorithm for compressive sensing of ECG signals. Moreover, to reduce processing time, classical signal-channel GAP is generalized to the multi-channel GAP algorithm, which simultaneously reconstructs multiple signals with similar support. Numerical experiments show that the proposed method outperforms the classical sparse multi-channel greedy algorithms in terms of accuracy and the single-channel cosparse approach in terms of processing speed.

  12. Immune System and Disorders

    Science.gov (United States)

    Your immune system is a complex network of cells, tissues, and organs that work together to defend against germs. It ... t, to find and destroy them. If your immune system cannot do its job, the results can be ...

  13. Long-distance multi-channel bidirectional chaos communication based on synchronized VCSELs subject to chaotic signal injection

    Science.gov (United States)

    Xie, Yi-Yuan; Li, Jia-Chao; He, Chao; Zhang, Zhen-Dong; Song, Ting-Ting; Xu, Chang-Jun; Wang, Gui-Jin

    2016-10-01

    A novel long-distance multi-channel bidirectional chaos communication system over multiple paths based on two synchronized 1550 nm vertical-cavity surface-emitting lasers (VCSELs) is proposed and studied theoretically. These two responding VCSELs (R-VCSELs) can output similar chaotic signals served as chaotic carrier in two linear polarization (LP) modes with identical signal injection from a driving VCSEL (D-VCSEL), which is subject to optical feedback and optical injection, simultaneously. Through the numerical simulations, high quality chaos synchronization between the two R-VCSELs can be obtained. Besides, the effects of varied qualities of chaos synchronization on communication performances in 20 km single mode fiber (SMF) channels are investigated by regulating different internal parameters mismatch after adopting chaos masking (CMS) technique. With the decrease of the maximum cross correlation coefficient (Max-C) between the two R-VCSELs, the bit error rate (BER) of decoded message increase. Meanwhile, the BER can still be less than 10-9 when the Max-C degrades to 0.982. Based on high quality synchronization, when the dispersion compensating fiber (DCF) links are introduced, 4n messages of 10 Gbit/s can transmit in 180 km SMF channels over n coupling paths, bidirectionally and simultaneously. Thorough tests are carried out with detailed analysis, demonstrating long-distance, multi-channel, bidirectional chaos communication based on VCSELs with chaotic signal injection.

  14. Multiplex multivariate recurrence network from multi-channel signals for revealing oil-water spatial flow behavior

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Yang, Yu-Xuan; Cai, Qing

    2017-03-01

    The exploration of the spatial dynamical flow behaviors of oil-water flows has attracted increasing interests on account of its challenging complexity and great significance. We first technically design a double-layer distributed-sector conductance sensor and systematically carry out oil-water flow experiments to capture the spatial flow information. Based on the well-established recurrence network theory, we develop a novel multiplex multivariate recurrence network (MMRN) to fully and comprehensively fuse our double-layer multi-channel signals. Then we derive the projection networks from the inferred MMRNs and exploit the average clustering coefficient and the spectral radius to quantitatively characterize the nonlinear recurrent behaviors related to the distinct flow patterns. We find that these two network measures are very sensitive to the change of flow states and the distributions of network measures enable to uncover the spatial dynamical flow behaviors underlying different oil-water flow patterns. Our method paves the way for efficiently analyzing multi-channel signals from multi-layer sensor measurement system.

  15. Spectrally Shaped DP-16QAM Super-Channel Transmission with Multi-Channel Digital Back-Propagation

    Science.gov (United States)

    Maher, Robert; Xu, Tianhua; Galdino, Lidia; Sato, Masaki; Alvarado, Alex; Shi, Kai; Savory, Seb J.; Thomsen, Benn C.; Killey, Robert I.; Bayvel, Polina

    2015-02-01

    The achievable transmission capacity of conventional optical fibre communication systems is limited by nonlinear distortions due to the Kerr effect and the difficulty in modulating the optical field to effectively use the available fibre bandwidth. In order to achieve a high information spectral density (ISD), while simultaneously maintaining transmission reach, multi-channel fibre nonlinearity compensation and spectrally efficient data encoding must be utilised. In this work, we use a single coherent super-receiver to simultaneously receive a DP-16QAM super-channel, consisting of seven spectrally shaped 10GBd sub-carriers spaced at the Nyquist frequency. Effective nonlinearity mitigation is achieved using multi-channel digital back-propagation (MC-DBP) and this technique is combined with an optimised forward error correction implementation to demonstrate a record gain in transmission reach of 85%; increasing the maximum transmission distance from 3190 km to 5890 km, with an ISD of 6.60 b/s/Hz. In addition, this report outlines for the first time, the sensitivity of MC-DBP gain to linear transmission line impairments and defines a trade-off between performance and complexity.

  16. A multi-channel biomimetic neuroprosthesis to support treadmill gait training in stroke patients.

    Science.gov (United States)

    Chia, Noelia; Ambrosini, Emilia; Baccinelli, Walter; Nardone, Antonio; Monticone, Marco; Ferrigno, Giancarlo; Pedrocchi, Alessandra; Ferrante, Simona

    2015-01-01

    This study presents an innovative multi-channel neuroprosthesis that induces a biomimetic activation of the main lower-limb muscles during treadmill gait training to be used in the rehabilitation of stroke patients. The electrostimulation strategy replicates the physiological muscle synergies used by healthy subjects to walk on a treadmill at their self-selected speed. This strategy is mapped to the current gait sub-phases, which are identified in real time by a custom algorithm. This algorithm divides the gait cycle into six sub-phases, based on two inertial sensors placed laterally on the shanks. Therefore, the pre-defined stimulation profiles are expanded or stretched based on the actual gait pattern of each single subject. A preliminary experimental protocol, involving 10 healthy volunteers, was carried out to extract the muscle synergies and validate the gait-detection algorithm, which were afterwards used in the development of the neuroprosthesis. The feasibility of the neuroprosthesis was tested on one healthy subject who simulated different gait patterns, and a chronic stroke patient. The results showed the correct functioning of the system. A pilot study of the neurorehabilitation treatment for stroke patients is currently being carried out.

  17. Multi-Input Multi-Channel Analyzer (MIMCA) using universal FPGA board

    CERN Document Server

    Andrianiaina, H; Andriambololona, Raoelina; Rambolamanana, G; Ratongasoandrazana, J B

    2015-01-01

    Instrumentation for nuclear applications is developing very fast, due to fast changing of technology in electronics in connection to Moore's Prediction ("doubling of transistor density integration on an IC for every two years"). The maintenance concept has changed accordingly and moved from repairing at electronic component level to software solving approach, which leads to customize application to fit the local needs. Therefore, Madagascar-INSTN has developed some R&D projects in instrumentation to support and fit to the local needs: one example is the FPGA-based Multi-Input Multi-Channel Analyzer using the UNIO52 standard board from J\\"ulich, which could be used to strengthen the capability and speed-up the routine for radionuclide measurement and analysis of samples. The test results of the MIMCA performance (Linearity, Count-rate accuracy tests) show that the configurable digital system can be used as an alternative issue compared to branded acquisition equipments, which are very expensive and limited...

  18. Multi-channel electromyography pattern classification using deep belief networks for enhanced user experience

    Institute of Scientific and Technical Information of China (English)

    SHIM Hyeon-min; LEE Sangmin

    2015-01-01

    An enhanced algorithm is proposed to recognize multi-channel electromyography (EMG) patterns using deep belief networks (DBNs). It is difficult to classify the EMG features because an EMG signal has nonlinear and time-varying characteristics. Therefore, in several previous studies, various machine-learning methods have been applied. A DBN is a fast, greedy learning algorithm that can find a fairly good set of weights rapidly, even in deep networks with a large number of parameters and many hidden layers. To evaluate this model, we acquired EMG signals, extracted their features, and then compared the model with the DBN and other conventional classifiers. The accuracy of the DBN is higher than that of the other algorithms. The classification performance of the DBN model designed is approximately 88.60%. It is 7.55% (p=9.82×10-12) higher than linear discriminant analysis (LDA) and 2.89% (p=1.94×10-5) higher than support vector machine (SVM). Further, the DBN is better than shallow learning algorithms or back propagation (BP), and this model is effective for an EMG-based user-interfaced system.

  19. Multi-channel poloidal correlation reflectometry on experimental advanced superconducting tokamak

    Science.gov (United States)

    Qu, H.; Zhang, T.; Han, X.; Xiang, H. M.; Wen, F.; Geng, K. N.; Wang, Y. M.; Kong, D. F.; Cai, J. Q.; Huang, C. B.; Gao, Y.; Gao, X.; Zhang, S.

    2016-11-01

    A new multi-channel poloidal correlation reflectometry is developed at Experimental Advanced Superconducting Tokamak. Eight dielectric resonator oscillators with frequencies of 12.5 GHz, 13.5 GHz, 14.5 GHz, 15 GHz, 15.5 GHz, 16 GHz, 17 GHz, and 18 GHz are used as sources. Signals from the sources are up-converted to V band using active quadruplers and then coupled together. The output waves are launched by one single antenna after passing through a 20 dB directional coupler which can provide the reference signal. Two poloidally separated antennae are installed to receive the reflected waves from plasma. The reference and reflected signals are down-converted by mixing with a quadrupled signal from a phase-locked source with a frequency of 14.2 GHz and the IF signals pass through the filter bank. The resulting signals from the mixers are detected by I/Q demodulators. The setup enables the measurement of density fluctuation at 8 (radial) × 2 (poloidal) spatial points. A coherent mode with an increasing velocity from 50 kHz to 100 kHz is observed by using the system. The mode is located in the steep gradient region of the pedestal.

  20. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    Science.gov (United States)

    Engel, G. L.; Duggireddi, N.; Vangapally, V.; Elson, J. M.; Sobotka, L. G.; Charity, R. J.

    2011-10-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC "tool box" for radiation detection instrumentation.

  1. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  2. A multi-channel model for an α plus {sup 6}He nucleus cluster

    Energy Technology Data Exchange (ETDEWEB)

    Amos, K.; Karataglidis, S. [University of Melbourne, School of Physics, Victoria (Australia); University of Johannesburg, Department of Physics, Auckland Park (South Africa); Canton, L. [Istituto Nazionale di Fisica Nucleare, Padova (Italy); Fraser, P.R. [Curtin University, Department of Physics, Astronomy and Medical Radiation Sciences, Perth (Australia); Svenne, J.P. [Department of Physics and Astronomy, University of Manitoba, and Winnipeg Institute for Theoretical Physics, Winnipeg, MB (Canada); Van der Knijff, D. [University of Melbourne, School of Physics, Victoria (Australia)

    2017-04-15

    A multi-channel algebraic scattering (MCAS) method has been used to solve coupled sets of Lippmann-Schwinger equations for the α + {sup 6}He cluster system, so finding a model spectrum for {sup 10}Be to more than 10MeV excitation. Three states of {sup 6}He were included and the resonance character of the two excited states taken into account in finding solutions. A model Hamiltonian has been found that gives very good agreement with the known bound states and with some low-lying resonances of {sup 10}Be. More resonance states are predicted than those which have been observed as yet. The method also yields S-matrices which we have used to evaluate low-energy {sup 6}He-α scattering cross sections. Reasonable reproduction of low-energy differential cross sections and of energy variation of cross sections measured at fixed scattering angles have been found. Enlarging the channel space by including two higher energy states of {sup 6}He, assuming values for their spin-parities, leads to an enlarged spectrum for {sup 10}Be in which the number and distribution of resonances show similarity to the known spectrum. (orig.)

  3. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  4. Cutaneous sensory nerve as a substitute for auditory nerve in solving deaf-mutes’ hearing problem: an innovation in multi-channel-array skin-hearing technology

    OpenAIRE

    Li, Jianwen; Li, Yan; Ming ZHANG; Ma, Weifang; Ma, Xuezong

    2014-01-01

    The current use of hearing aids and artificial cochleas for deaf-mute individuals depends on their auditory nerve. Skin-hearing technology, a patented system developed by our group, uses a cutaneous sensory nerve to substitute for the auditory nerve to help deaf-mutes to hear sound. This paper introduces a new solution, multi-channel-array skin-hearing technology, to solve the problem of speech discrimination. Based on the filtering principle of hair cells, external voice signals at different...

  5. Pulse-width tunable multi-channel NRZ-to-RZ conversion with duplicate output

    Science.gov (United States)

    Yu, Yu; Zhang, Xinliang; Huang, Dexiu

    2012-01-01

    We demonstrate multi-channel non-return-to-zero (NRZ) to return-to-zero (RZ) conversions with tunable output pulse-width and single-to-dual function, using a phase modulator and an array waveguide grating (AWG), which acts both detuned multi-channel filter and demultiplexer. Four-channel NRZ signals after transmission can be converted to eight-channel RZ signals with timing jitter and extinction ratio improvement. Further transmission and bit error ratio (BER) measurements for the converted RZ signal show a good performance compared with conventional one.

  6. Study on the separation performance of the multi-channel reduced graphene oxide membranes

    Science.gov (United States)

    Zhao, Yongjiao; Li, Chun; Fan, Xiaoyan; Wang, Jiesheng; Yuan, Guang; Song, Xinxiang; Chen, Jing; Li, Zhangde

    2016-10-01

    The multi-channel reduced graphene oxide membranes with separation function have been synthesized by a simple hydrothermal reduction method and vacuum filtration. In the as-synthesized membranes, the size, number, and type of the nanochannels can be controlled by the reduced temperature. The flux and retention rate of solution are investigated by filtering different size dye molecules. The interception and adsorption effect in the separation process are discussed. Furthermore, the sizes of the nanochannels in the membranes prepared by the different reduced temperatures are estimated. The results indicate that the multi-channel reduced graphene oxide membranes have potential application in water purification area.

  7. Disorder in Complex Human System

    Science.gov (United States)

    Akdeniz, K. Gediz

    2011-11-01

    Since the world of human and whose life becomes more and more complex every day because of the digital technology and under the storm of knowledge (media, internet, governmental and non-governmental organizations, etc...) the simulation is rapidly growing in the social systems and in human behaviors. The formation of the body and mutual interactions are left to digital technological, communication mechanisms and coding the techno genetics of the body. Deconstruction begins everywhere. The linear simulation mechanism with modern realities are replaced by the disorder simulation of human behaviors with awareness realities. In this paper I would like to introduce simulation theory of "Disorder Sensitive Human Behaviors". I recently proposed this theory to critique the role of disorder human behaviors in social systems. In this theory the principle of realty is the chaotic awareness of the complexity of human systems inside of principle of modern thinking in Baudrillard's simulation theory. Proper examples will be also considered to investigate the theory.

  8. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...... or the second side of the wavelength converter system. Finally, the spectrometer comprises a spatially resolved detector arranged in the image plane to detect light in the first output wavelength range and second output wavelength range output of the wavelength converter system....

  9. Photon counting with photon number resolution through superconducting nanowires coupled to a multi-channel TDC in FPGA

    Science.gov (United States)

    Lusardi, N.; Los, J. W. N.; Gourgues, R. B. M.; Bulgarini, G.; Geraci, A.

    2017-03-01

    The paper presents a system for measuring photon statistics and photon timing in the few-photon regime down to the single-photon level. The measurement system is based on superconducting nanowire single photon detectors and a time-to-digital converter implemented into a programmable device. The combination of these devices gives high performance to the system in terms of resolution and adaptability to the actual experimental conditions. As a case of application, we present the measurement of photon statistics for coherent light states. In this measurement, we make use of 8th order single photon correlations to reconstruct with high fidelity the statistics of a coherent state with average photon number up to 4. The processing is performed by means of a tapped-delay-line time-to-digital converter architecture that also hosts an asynchronous-correlated-digital-counter implemented in a field programmable gate array device and specifically designed for performance optimization in multi-channel usage.

  10. [Software development of multi-element transient signal acquisition and processing with multi-channel ICP-AES].

    Science.gov (United States)

    Zhang, Y; Zhuang, Z; Wang, X; Zhu, E; Liu, J

    2000-02-01

    A software for multi-channel ICP-AES multi-element transient signal acquisition and processing were developed in this paper. It has been successfully applied to signal acquisition and processing in many transient introduction techniques on-line hyphenated with multi-channel ICP-AES.

  11. Development of Ribbon Fiber Type Multi-Channel Power Level Monitor with Low-Insertion/Polarization Loss

    Institute of Scientific and Technical Information of China (English)

    Maki; Inai; Akira; Haraguchi; Takeo; Komiya; Kiyotaka; Murashima; Takashi; Sasaki; Kazuhito; Saitoh

    2003-01-01

    We would like to propose a new in-line multi-channel power level monitor, which is applicable as tap-monitor for multi-channel WDM signals. Its ribbon fiber structure has far exceeded PLC performance and realized compact-size and lower insertion/polarization dependent loss.

  12. Using image synthesis for multi-channel registration of different image modalities

    Science.gov (United States)

    Chen, Min; Jog, Amod; Carass, Aaron; Prince, Jerry L.

    2015-01-01

    This paper presents a multi-channel approach for performing registration between magnetic resonance (MR) images with different modalities. In general, a multi-channel registration cannot be used when the moving and target images do not have analogous modalities. In this work, we address this limitation by using a random forest regression technique to synthesize the missing modalities from the available ones. This allows a single channel registration between two different modalities to be converted into a multi-channel registration with two mono-modal channels. To validate our approach, two openly available registration algorithms and five cost functions were used to compare the label transfer accuracy of the registration with (and without) our multi-channel synthesis approach. Our results show that the proposed method produced statistically significant improvements in registration accuracy (at an α level of 0.001) for both algorithms and all cost functions when compared to a standard multi-modal registration using the same algorithms with mutual information. PMID:26246653

  13. E-Fulfillment and Multi-Channel Distribution – A Review

    NARCIS (Netherlands)

    N.A.H. Agatz (Niels); M. Fleischmann (Moritz); J.A.E.E. van Nunen (Jo)

    2006-01-01

    textabstractThis review addresses the specific supply chain management issues of Internet fulfillment in a multi-channel environment. It provides a systematic overview of managerial planning tasks and reviews corresponding quantitative models. In this way, we aim to enhance the understanding of mult

  14. Designing Multi-Channel Web Frameworks for Cultural Tourism Applications: The MUSE Case Study.

    Science.gov (United States)

    Garzotto, Franca; Salmon, Tullio; Pigozzi, Massimiliano

    A framework for the design of multi-channel (MC) applications in the cultural tourism domain is presented. Several heterogeneous interface devices are supported including location-sensitive mobile units, on-site stationary devices, and personalized CDs that extend the on-site experience beyond the visit time thanks to personal memories gathered…

  15. Self-adaptive method for high frequency multi-channel analysis of surface wave method

    Science.gov (United States)

    When the high frequency multi-channel analysis of surface waves (MASW) method is conducted to explore soil properties in the vadose zone, existing rules for selecting the near offset and spread lengths cannot satisfy the requirements of planar dominant Rayleigh waves for all frequencies of interest ...

  16. Exploring the complementarity of THz pulse imaging and DCE-MRIs: Toward a unified multi-channel classification and a deep learning framework.

    Science.gov (United States)

    Yin, X-X; Zhang, Y; Cao, J; Wu, J-L; Hadjiloucas, S

    2016-12-01

    We provide a comprehensive account of recent advances in biomedical image analysis and classification from two complementary imaging modalities: terahertz (THz) pulse imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The work aims to highlight underlining commonalities in both data structures so that a common multi-channel data fusion framework can be developed. Signal pre-processing in both datasets is discussed briefly taking into consideration advances in multi-resolution analysis and model based fractional order calculus system identification. Developments in statistical signal processing using principal component and independent component analysis are also considered. These algorithms have been developed independently by the THz-pulse imaging and DCE-MRI communities, and there is scope to place them in a common multi-channel framework to provide better software standardization at the pre-processing de-noising stage. A comprehensive discussion of feature selection strategies is also provided and the importance of preserving textural information is highlighted. Feature extraction and classification methods taking into consideration recent advances in support vector machine (SVM) and extreme learning machine (ELM) classifiers and their complex extensions are presented. An outlook on Clifford algebra classifiers and deep learning techniques suitable to both types of datasets is also provided. The work points toward the direction of developing a new unified multi-channel signal processing framework for biomedical image analysis that will explore synergies from both sensing modalities for inferring disease proliferation.

  17. Cutaneous sensory nerve as a substitute for auditory nerve in solving deaf-mutes’ hearing problem:an innovation in multi-channel-array skin-hearing technology

    Institute of Scientific and Technical Information of China (English)

    Jianwen Li; Yan Li; Ming Zhang; Weifang Ma; Xuezong Ma

    2014-01-01

    The current use of hearing aids and artificial cochleas for deaf-mute individuals depends on their auditory nerve. Skin-hearing technology, a patented system developed by our group, uses a cutaneous sensory nerve to substitute for the auditory nerve to help deaf-mutes to hear sound. This paper introduces a new solution, multi-channel-array skin-hearing technology, to solve the problem of speech discrimination. Based on the ifltering principle of hair cells, external voice sig-nals at different frequencies are converted to current signals at corresponding frequencies using electronic multi-channel bandpass ifltering technology. Different positions on the skin can be stimulated by the electrode array, allowing the perception and discrimination of external speech signals to be determined by the skin response to the current signals. Through voice frequen-cy analysis, the frequency range of the band-pass iflter can also be determined. These ifndings demonstrate that the sensory nerves in the skin can help to transfer the voice signal and to dis-tinguish the speech signal, suggesting that the skin sensory nerves are good candidates for the replacement of the auditory nerve in addressing deaf-mutes’ hearing problems. Scientiifc hearing experiments can be more safely performed on the skin. Compared with the artificial cochlea, multi-channel-array skin-hearing aids have lower operation risk in use, are cheaper and are more easily popularized.

  18. Cutaneous sensory nerve as a substitute for auditory nerve in solving deaf-mutes' hearing problem: an innovation in multi-channel-array skin-hearing technology.

    Science.gov (United States)

    Li, Jianwen; Li, Yan; Zhang, Ming; Ma, Weifang; Ma, Xuezong

    2014-08-15

    The current use of hearing aids and artificial cochleas for deaf-mute individuals depends on their auditory nerve. Skin-hearing technology, a patented system developed by our group, uses a cutaneous sensory nerve to substitute for the auditory nerve to help deaf-mutes to hear sound. This paper introduces a new solution, multi-channel-array skin-hearing technology, to solve the problem of speech discrimination. Based on the filtering principle of hair cells, external voice signals at different frequencies are converted to current signals at corresponding frequencies using electronic multi-channel bandpass filtering technology. Different positions on the skin can be stimulated by the electrode array, allowing the perception and discrimination of external speech signals to be determined by the skin response to the current signals. Through voice frequency analysis, the frequency range of the band-pass filter can also be determined. These findings demonstrate that the sensory nerves in the skin can help to transfer the voice signal and to distinguish the speech signal, suggesting that the skin sensory nerves are good candidates for the replacement of the auditory nerve in addressing deaf-mutes' hearing problems. Scientific hearing experiments can be more safely performed on the skin. Compared with the artificial cochlea, multi-channel-array skin-hearing aids have lower operation risk in use, are cheaper and are more easily popularized.

  19. High Speed, Multi-Channel, Thermal Instrument Development in Support of HyspIRI-TIR

    Science.gov (United States)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2011-01-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

  20. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  1. Circular microphone array for multi channel audio recording

    NARCIS (Netherlands)

    Hulsebos, E.M.; De Vries, D.; Boone, M.M.; Schuurmans, T.J.G.

    2004-01-01

    An audio system has a circular microphone array with a number of microphones arranged on a circle for receiving a sound field. A digital signal processor is provided for processing output signals from these microphones. To establish well controlled and sharp directivity patterns the audio system per

  2. Multi-channel wireless sensor networks : protocols, design and evaluation

    NARCIS (Netherlands)

    Durmaz Incel, Özlem

    2009-01-01

    Pervasive systems, which are described as networked embedded systems integrated with everyday environments, are considered to have the potential to change our daily lives by creating smart surroundings and by their ubiquity, just as the Internet. In the last decade, “Wireless Sensor Networks” have a

  3. Multi-Channel Wireless Sensor Networks: Protocols, Design and Evaluation

    NARCIS (Netherlands)

    Durmaz, O.

    2009-01-01

    Pervasive systems, which are described as networked embedded systems integrated with everyday environments, are considered to have the potential to change our daily lives by creating smart surroundings and by their ubiquity, just as the Internet. In the last decade, “Wireless Sensor Networks��? have

  4. A new architecture for a single-chip multi-channel beamformer based on a standard FPGA

    DEFF Research Database (Denmark)

    Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2001-01-01

    A new architecture for a compact medical ultrasound beamformer has been developed. Combination of novel and known principles has been utilized, leading to low processing power requirements and simple analog circuitry. Usage of a field programmable gate array (FPGA) for the digital signal processing...... integrated circuit. Third, parameter driven delay generation is used, using 3 input parameters per line per channel for either linear array imaging or phased array imaging. The delays are generated on the fly. The delay generation logic also determines the digital apodization by using 2 additional parameters....... The control logic consists of few adders and counters and requires very limited resources. Fourth, the beamformer is fully programmable. Any channel can be set to use an arbitrary delay curve, and any number of these channels can be used together in an extendable modular multi-channel system. A prototype...

  5. CFD-based optimization and design of multi-channel inorganic membrane tubes☆

    Institute of Scientific and Technical Information of China (English)

    Zhao Yang; Jingcai Cheng; Chao Yang; Bin Liang

    2016-01-01

    As a major configuration of membrane elements, multi-channel porous inorganic membrane tubes were studied by means of theoretical analysis and simulation. Configuration optimization of a cylindrical 37-channel porous inorganic membrane tube was studied by increasing membrane filtration area and increasing permeation effi-ciency of inner channels. An optimal ratio of the channel diameter to the inter-channel distance was proposed so as to increase the total membrane filtration area of the membrane tube. The three-dimensional computational fluid dynamics (CFD) simulation was conducted to study the cross-flow permeation flow of pure water in the 37-channel ceramic membrane tube. A model combining Navier–Stokes equation with Darcy's law and the porous jump boundary conditions was applied. The relationship between permeation efficiency and channel locations, and the method for increasing the permeation efficiency of inner channels were proposed. Some novel multi-channel membrane configurations with more permeate side channels were put forward and evaluated.

  6. Analysis of Magnetic Field Inducted in Brain by Multi-Channel Magnetic Stimulation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Multi-channel magnetic stimulation is an efficient method to improve the conventional magnetic stimulation. A multi-channel magnetic brain stimulator was developed and the distribution of magnetic field was calculated by finite-element analysis software-ANSYS. The results show that when five coils work simultaneously, the area where the magnetic flux density is larger than 0.01 T would expand to almost the whole brain region, and the magnetic stimulation depth would be improved.Experiments were performed on ten subjects (mean age 25) using the stimulator, and the EEG power spectrums before and after stimulation were analyzed. The experimental results show that the beta component of EEG obviously increases after magnetic stimulation, and the effect is more obvious by using more coils simultaneously because of the deeper stimulation.

  7. A robotic multi-channel platform for interstitial photodynamic therapy

    Science.gov (United States)

    Sharikova, Anna V.; Finlay, Jarod C.; Dimofte, Andreea; Zhu, Timothy C.

    2013-03-01

    A custom-made robotic multichannel platform for interstitial photodynamic therapy (PDT) and diffuse optical tomography (DOT) was developed and tested in a phantom experiment. The system, which was compatible with the operating room (OR) environment, had 16 channels for independent positioning of light sources and/or isotropic detectors in separate catheters. Each channel's motor had an optical encoder for position feedback, with resolution of 0.05 mm, and a maximum speed of 5 cm/s. Automatic calibration of detector positions was implemented using an optical diode beam that defined the starting position of each motor, and by means of feedback algorithms controlling individual channels. As a result, the accuracy of zero position of 0.1 mm for all channels was achieved. We have also employed scanning procedures where detectors automatically covered the appropriate range around source positions. Thus, total scan time for a typical optical properties (OP) measurement throughout the phantom was about 1.5 minutes with point sources. The OP were determined based on the measured light fluence rates. These enhancements allow a tremendous improvement of treatment quality for a bulk tumor compared to the systems employed in previous clinical trials.

  8. Analysis of Multi-Channel and Slotted Random Multi-Access Protocol with Two-Dimensional Probability for Ad Hoc Network

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ningyu; ZHAO Dongfeng; DING Hongwei

    2008-01-01

    A higher quality of service (QoS) is provided for ad hoc networks through a multi-channel and slotted random multi-access (MSRM) protocol with two-dimensional probability. For this protocol, the system time is slotted into a time slot with high channel utilization realized by the choice of two parameters p1 and p2, and the channel load equilibrium. The protocol analyzes the throughput of the MSRM protocol for a load equilibrium state and the throughput based on priority. Simulations agree with the theoretical analysis. The simulations also show that the slotted-time system is better than the continuous-time system.

  9. Self-aligned multi-channel superconducting nanowire avalanche photodetector

    CERN Document Server

    Cheng, Risheng; Ma, Xiaosong; Fan, Linran; Fong, King Y; Poot, Menno; Tang, Hong X

    2016-01-01

    We describe a micromachining process to allow the coupling of an array of single-mode telecommunication fibers to individual superconducting nanowire single photon detectors (SNSPDs). As proof of principle, we show the integration of four detectors on the same silicon chip, including two standard single-section nanowire detectors and two superconducting nanowire avalanche photodetectors (SNAPs) with modified series structure without external inductor, and their performances are compared. The SNAP shows saturated system detection efficiency of 16% while the dark count rate is less than 20 Hz, without the use of photon-recycling reflectors. The SNAP also demonstrates doubled signal-to-noise ratio, reduced reset time (~ 4.9 ns decay time) and improved timing jitter (62 ps FWHM) compared to standard SNSPDs.

  10. Multi-channel high-resolution terahertz spectrometer for analytical studies

    Science.gov (United States)

    Vaks, V.; Domracheva, E.; Pripolzin, S.; Chernyaeva, M.; Yablokov, A.

    2016-12-01

    A method of multi-channel THz spectroscopy and a sample device that embodies the method were developed and described by the authors. The device has two independent THz radiation sources and a single receiving module. The novel method allows detecting preliminary and short-living chemical compounds and therefore to studychemical reaction dynamics. This has been shown by a series of test experiments. The method can be applied to researches in Physics, Chemistry, Astronomy, Medicine, and Biology.

  11. The interface design for the USB-based multi-channel analyzer

    CERN Document Server

    Sun Guang Cai

    2002-01-01

    A new style interface circuit design for multi-channel analyzer is introduced, which takes the advantages of Universal Serial Bus to communicate with computer and gets the merit of high universality and Plug and Play. The interface circuit also uses dual-port SRAM and high-speed MCU to store and translate data, which could solve the bottleneck problem existing in data translation from the interface to computer

  12. High dynamic range multi-channel cross-correlator for single-shot temporal contrast measurement

    Science.gov (United States)

    Kon, A.; Nishiuchi, M.; Kiriyama, H.; Ogura, K.; Mori, M.; Sakaki, H.; Kando, M.; Kondo, K.

    2016-05-01

    We have developed a multi-channel cross-correlator for high dynamic range (>1010), single-shot temporal contrast measurements. The correlator utilizes a third-order crosscorrelation technique and has a reference channel, to be normalized by the measured peak intensity, and four independent optical delay lines. The measurement results of the shot-to-shot temporal contrast clearly show the intensity fluctuations of short pre-pulses at -4.5 ps and -26 ps before main pulse.

  13. An integrated analog O/E/O link for multi-channel laser neurons

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, Mitchell A., E-mail: mnahmias@princeton.edu; Tait, Alexander N.; Tolias, Leonidas; Chang, Matthew P.; Ferreira de Lima, Thomas; Shastri, Bhavin J.; Prucnal, Paul R. [Electrical Engineering Department, Princeton University, 41 Olden St, Princeton, New Jersey 08540 (United States)

    2016-04-11

    We demonstrate an analog O/E/O electronic link to allow integrated laser neurons to accept many distinguishable, high bandwidth input signals simultaneously. This device utilizes wavelength division multiplexing to achieve multi-channel fan-in, a photodetector to sum signals together, and a laser cavity to perform a nonlinear operation. Its speed outpaces accelerated-time neuromorphic electronics, and it represents a viable direction towards scalable networking approaches.

  14. High performance multi-channel MOSFET on InGaAs for RF amplifiers

    Science.gov (United States)

    Adhikari, Manoj Singh; Singh, Yashvir

    2017-02-01

    In this paper, we propose a multi-channel MOSFET (MC-MOSFET) on In0.53Ga0.47As for the first time by utilising trenches in the conventional planar MOSFET (CP-MOSFET) for RF amplifier applications. The proposed multi-channel MOSFET (MC-MOSFET) has two vertical-gates placed in trenches creating multiple channels in p-body for parallel conduction of drain current. High-k Al2O3 having thickness of 2 nm is used as gate dielectric in the proposed device. The TaN gate electrodes are placed in two different trenches in the p-type InGaAs layer where multiple n-channels are formed. Simultaneous conduction from multiple channels enhances the drain current (ID) and gives higher transconductance (gm) leading to improvement in overall frequency response. Two-dimensional (2D) numerical simulations of both MC-MOSFET and CP-MOSFET are performed by using ATLAS device simulator and their different performance parameters are compared. The proposed multi-channel structure provides 6.79 times higher ID, 5.57 times improvement in gm, 2.5 times increase in unity current gain (ft), 15.85% higher unilateral power gain (fmax) and suppress the short-channel effects (SCEs) as compared with the CP-MOSFET.

  15. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  16. Single-channel and multi-channel orthogonal matching pursuit for seismic trace decomposition

    Science.gov (United States)

    Feng, Xuan; Zhang, Xuebing; Liu, Cai; Lu, Qi

    2017-02-01

    The conventional matching pursuit (MP) algorithm can decompose a 1D signal into a set of wavelet atoms adaptively. As to reflection seismic data, some applicable algorithms based on the MP decomposition has been developed, such as single-channel matching pursuit (SCMP) and multi-channel matching pursuit (MCMP). However, these algorithms cannot always select the optimal atoms, which results in less meaningful decompositions. To overcome this limitation, we introduce the idea of orthogonal matching pursuit into a multi-channel decomposition scheme, which we refer to as the multi-channel orthogonal matching pursuit (MCOMP). Each iteration of the proposed MCOMP might extract a more reasonable atom among a redundant Morlet wavelet dictionary, like the MCMP decomposition does, and estimate the corresponding amplitude more accurately by solving a least-squares problem. In order to correspond to SCMP, we also simplified the MCOMP decomposition to single-channel orthogonal matching pursuit (SCOMP) for decompositions of an individual seismic trace. We tested the proposed SCOMP algorithm on a synthetic signal and a field seismic trace. Then a field marine dataset example showed relative high resolution of the proposed MCOMP method with applications to the detection of low-frequency anomalies. These application examples all demonstrate more meaningful decomposition results and relative high convergence speed of the proposed algorithms.

  17. Parallel encryption for multi-channel images based on an optical joint transform correlator

    Science.gov (United States)

    Liu, Jie; Bai, Tingzhu; Shen, Xueju; Dou, Shuaifeng; Lin, Chao; Cai, Jianjun

    2017-08-01

    We propose an optical encryption method allowing the parallel encryption for multi-channel images based on a joint transform correlator (JTC). Distinguished from the conventional multi-image encryption methods, our proposed cryptosystem can encrypt multi-channel images simultaneously into a single ciphertext, which also can be used to recover arbitrary original images with corresponding keys. This method can achieve the compressed storage of ciphertext. In order to avoid the cross talk between multi-channel images, we restrict the respective joint power spectrum (JPS) into a specific area with optimized phase masks and split the multiple JPS by controlling the position of single JPS using the linear phase shifts. All of these operations are realized by optimizing and designing the phase masks which can be flexibly reconfigured on the spatial light modulator (SLM), leading to a feasible optical implementation with no increase of optical hardware and complexity. Computer simulations provide the validation for it. Experimental implementation is performed in a JTC-based cryptosystem to further verify the feasibility of our proposed method.

  18. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network.

    Science.gov (United States)

    Lin, Kai; Wang, Di; Hu, Long

    2016-07-01

    With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC). The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S) evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  19. Multi-channel micro neural probe fabricated with SOI

    Institute of Scientific and Technical Information of China (English)

    PEI WeiHua; ZHU Lin; WANG ShuJing; GUO Kai; TANG Jun; ZHANG Xu; LU Lin; GAO ShangKai; CHEN HongDa

    2009-01-01

    Silicon-on-insulator (SOI) substrate is widely used in micro-electro-mechanical systems (MEMS). With the buried oxide layer of SOl acting as an etching stop, silicon based micro neural probe can be fabri-cated with improved uniformity and manufacturability. A seven-record-site neural probe was formed by inductive-coupled plasma (ICP) dry etching of an SOl substrate. The thickness of the probe is 15 μm.The shaft of the probe has dimensions of 3 mmx100 μmx15 μm with typical area of the record site of 78.5 μm2. The impedance of the record site was measured in-vitro. The typical impedance characteris-tics of the record sites are around 2 MΩ at 1 kHz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 μV. Spike from individual site could exceed 700 μV. The average signal noise ratio was 7 or more.

  20. Multi-channel micro neural probe fabricated with SOI

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Silicon-on-insulator(SOI) substrate is widely used in micro-electro-mechanical systems(MEMS).With the buried oxide layer of SOI acting as an etching stop,silicon based micro neural probe can be fabri-cated with improved uniformity and manufacturability.A seven-record-site neural probe was formed by inductive-coupled plasma(ICP) dry etching of an SOI substrate.The thickness of the probe is 15 μm.The shaft of the probe has dimensions of 3 mm×100 μm×15 μm with typical area of the record site of 78.5 μm2.The impedance of the record site was measured in-vitro.The typical impedance characteris-tics of the record sites are around 2 MΩ at 1 kHz.The performance of the neural probe in-vivo was tested on anesthetic rat.The recorded neural spike was typically around 140 μV.Spike from individual site could exceed 700 μV.The average signal noise ratio was 7 or more.

  1. Multipoint entanglement in disordered systems

    Science.gov (United States)

    Magán, Javier M.; Paganelli, Simone; Oganesyan, Vadim

    2017-02-01

    We develop an approach to characterize excited states of disordered many-body systems using spatially resolved structures of entanglement. We show that the behavior of the mutual information (MI) between two parties of a many-body system can signal a qualitative difference between thermal and localized phases - MI is finite in insulators while it approaches zero in the thermodynamic limit in the ergodic phase. Related quantities, such as the recently introduced Codification Volume (CV), are shown to be suitable to quantify the correlation length of the system. These ideas are illustrated using prototypical non-interacting wavefunctions of localized and extended particles and then applied to characterize states of strongly excited interacting spin chains. We especially focus on evolution of spatial structure of quantum information between high temperature diffusive and many-body localized (MBL) phases believed to exist in these models. We study MI as a function of disorder strength both averaged over the eigenstates and in time-evolved product states drawn from continuously deformed family of initial states realizable experimentally. As expected, spectral and time-evolved averages coincide inside the ergodic phase and differ significantly outside. We also highlight dispersion among the initial states within the localized phase - some of these show considerable generation and delocalization of quantum information.

  2. Design and implementation of the optical fiber control and transmission module in multi-channel broadband digital receiver

    Science.gov (United States)

    Zhao, Ying-xiao; Zhang, Yue; Fan, Li-jie; Li, Wei-xing; Chen, Zeng-ping

    2014-09-01

    An optical fiber control and transmission module is designed and realized based on Virtex-7 field programmable gata array (FPGA), which can be applied in multi-channel broadband digital receivers. The module consists of sampling data transfer submodule and multi-channel synchronous sampling control submodule. The sampling data transmission in 4× fiber link channel is realized with the self-defined transfer protocol. The measured maximum data rate is 4.97 Gbyte/s. By connecting coherent clocks to the transmitter and receiver endpoints and using the self-defined transfer protocol, multi-channel sampling control signals transferred in optical fibers can be received synchronously by each analog-to-digital converter (ADC) with high accuracy and strong anti-interference ability. The module designed in this paper has certain reference value in increasing the transmission bandwidth and the synchronous sampling accuracy of multi-channel broadband digital receivers.

  3. Classical transport in disordered systems

    Science.gov (United States)

    Papaioannou, Antonios

    This thesis reports on the manifestation of structural disorder on molecular transport and it consists of two parts. Part I discusses the relations between classical transport and the underlying structural complexity of the system. Both types of molecular diffusion, namely Gaussian and non- Gaussian are presented and the relevant time regimes are discussed. In addition the concept of structural universality is introduced and connected with the diffusion metrics. One of the most robust techniques for measuring molecular mean square displacements is magnetic resonance. This method requires encoding and subsequently reading out after an experimentally controlled time, a phase φ to the spins using magnetic field gradients. The main limitation for probing short diffusion lengths L(t) ˜ 1micro m with magnetic resonance is the requirement to encode and decode the phase φ in very short time intervals. Therefore, to probe such displacements a special probe was developed equipped with a gradient coil capable of delivering magnetic field gradients of approximately 90 G/cmA . The design of the probe is reported. Part I also includes a discussion of experiments of transport in two qualitatively different disordered phantoms and reports on a direct observation of universality in one-dimension. The results reveal the universal power law scaling of the diffusion coefficient at the long-time regime and illustrate the essence of structural universality by experimentally determining the structure correlation function of the phantoms. In addition, the scaling of the diffusive permeability of the phantoms with respect to the pore size is investigated. Additional work presented includes a detailed study of adsorption of methane gas in Vycor disordered glass. The techniques described in Part I of this thesis are widely used for measuring structural parameters of porous media, such as the surface-to-volume ratio or diffusive permeability. Part II of this thesis discusses the

  4. Multi-channel programmable power supply with temperature compensation for silicon sensors

    Science.gov (United States)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R.; Freeman, J.; Garde, C. S.; Gupta, S. K.; Khandekar, P. D.; Kurup, A. M.; Lokhandwala, S. S.; Los, S.; Prabhu, S. S.; Rakshe, P. S.

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The

  5. Multi-channel programmable power supply with temperature compensation for silicon sensors

    Energy Technology Data Exchange (ETDEWEB)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R., E-mail: dugad@cern.ch; Kurup, A. M.; Lokhandwala, S. S.; Prabhu, S. S. [Tata Institute of Fundamental Research, Mumbai 400005 (India); Freeman, J.; Los, S. [Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States); Garde, C. S.; Khandekar, P. D. [Vishwakarma Institute of Information Technology, Pune 411048 (India); Gupta, S. K. [Tata Institute of Fundamental Research, Mumbai 400005 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India); Rakshe, P. S. [Vishwakarma Institute of Information Technology, Pune 411048 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India)

    2016-01-15

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  6. Multi-channel Acquisition of Spread Spectrum Signal based on PMF-FFT%基于PMF-FFT的扩频信号多通道并行捕获

    Institute of Scientific and Technical Information of China (English)

    方科

    2013-01-01

    PMF-FFT (Partial Matched Filters combined with Fast Fourier Transform) is increasingly applied in spread spectrum TT&C system for achieving the acquisition of spread spectrum signal. This paper analyzes theory, process and performance of PMF-FFT in acquiring spread spectrum signal. In order to match different acquisition demands of spread spectrum TT&C system, two implementations are proposed, which make full use of the multi-channel parallel processing architecture based on PMF-FFT by Multi-channel parallel acquisition in frequency and Multi-channel parallel acquisition in time-domain.%  目前在扩频测控通信系统中越来越多地采用了部分匹配滤波和快速傅里叶变换(PMF-FFT)的方法来实现扩频信号的捕获,这里分析了 PMF-FFT 实现扩频信号捕获的算法原理、过程和性能,充分利用多通道并行处理架构,提出了基于 PMF-FFT 的频域(频率分槽)多通道并行捕获和时域(伪码分区)多通道并行捕获两种不同的实现方法,以满足不同的扩频测控通信系统对伪码捕获性能的应用需求。

  7. Spin susceptibility of disordered gapped graphene systems

    Science.gov (United States)

    Grosu, I.; Biter, T. L.

    2017-02-01

    We calculate the spin susceptibility for the case of gapped graphene systems in the presence of disorder. The average single-particle density of states in gapped graphene with disorder was calculated, using the Born and the T-matrix approximations. The temperature dependence of the static spin susceptibility was analyzed. The influence of the chemical potential position and disorder is also discussed.

  8. Disordered Holographic Systems I: Functional Renormalization

    CERN Document Server

    Adams, Allan

    2011-01-01

    We study quenched disorder in strongly correlated systems via holography, focusing on the thermodynamic effects of mild electric disorder. Disorder is introduced through a random potential which is assumed to self-average on macroscopic scales. Studying the flow of this distribution with energy scale leads us to develop a holographic functional renormalization scheme. We test this scheme by computing thermodynamic quantities and confirming that the Harris criterion for relevance, irrelevance or marginality of quenched disorder holds.

  9. Multi-channel analysis of passive surface waves based on cross-correlations

    Science.gov (United States)

    Cheng, F.; Xia, J.; Xu, Z.; Hu, Y.

    2015-12-01

    Traditional active seismic survey can no longer be properly applied in highly populated urban areas due to restrictions in modern civilian life styles. Passive seismic methods, however, have gained much more attention from the engineering geophysics community because of their environmental friendly and deeper investigation depth. Due to extracting signal from noise has never been as comfortable as that in active seismic survey, how to make it more efficiently and accurately has been emphasized. We propose a multi-channel analysis of passive surface waves (MAPW) based on long noise sequences cross-correlations to meet the demand for increasing investigation depth by acquiring surface-wave data at a relative low-frequency range (1 Hz ≤ f ≤ 10 Hz) in urban areas. We utilize seismic interferometry to produce common virtual source gathers from one-hour-long noise records and do dispersion measurements by using the classic passive multi-channel analysis of surface waves (PMASW). We used synthetic tests to demonstrate the advantages of MAPW for various noise distributions. Results show that our method has the superiority of maximizing the analysis accuracy. Finally, we used two field data applications to demonstrate the advantages of our MAPW over the classic PMASW on isolating azimuth of the predominant noise sources and the effectivity of combined survey of active multi-channel analysis of surface waves (MASW) and MAPW. We suggest, for the field operation using MAPW, that a parallel receiver line which is close to a main road or river, if any, with one or two hours noise observation will be an effective means for an unbiased dispersion image. Keywords: passive seismic method, MAPW, MASW, cross-correlation, directional noise source, spatial-aliasing effects, inversion

  10. A Multi-channel Pre-processing Circuit for Signals from Thermocouple/Thermister

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper,a new developed multi-channel pre-processing circuit for signals from temperature sensor was introduced in brief.This circuit was developed to collect and amplify the signals from temperature sensor.This is a universal circuit.It can be used to process the signals from thermocouples and also used to process signals from thermistors.This circuit was mounted in a standard box(440W×405D×125H mm)as an instrument.The

  11. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt;

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic....... The dereverberation performance of the algorithm is evaluated using computer simulations with realistic hearing aid microphone signals including head-related effects. The algorithm is shown to work well with signals reverberated both by synthetic and by measured room impulse responses, achieving improvements...

  12. 4 × 160-Gbit/s multi-channel regeneration in a single fiber

    DEFF Research Database (Denmark)

    Wang, Ju; Ji, Hua; Hu, Hao;

    2014-01-01

    Simultaneous regeneration of four high-speed (160 Gbit/s) wavelength-division multiplexed (WDM) and polarization-division multiplexed (PDM) signals in a single highly nonlinear fiber (HNLF) is demonstrated. The regeneration operation is based on four-wave mixing in HNLF, where the degraded data...... phase modulation of the CW light. Mitigation of the inter-channel nonlinearities is achieved mainly through an inter-channel 0.5 bit slot time delay. Bidirectional propagation is also applied to relieve the inter-channel four-wave mixing. The multi-channel regeneration performance is validated by bit...

  13. A Multi-Channel MAC Protocol For Wireless Hospital Sensor Networks

    CERN Document Server

    Slimane, Jamila Ben; Frikha, Mounir; Koubâa, Anis

    2008-01-01

    Both IEEE 802.15.4 and 802.15.4a standards allow for dynamic channel allocation and use of multiple channels available at their physical layers but its MAC protocols are designed only for single channel. Also, sensor's transceivers such as CC2420 provide multiple channels and channel switch latency of CC2420 transceiver is very short just about 200 micro seconds. In order to enhance both energy efficiency and to shorten end to end delay, we propose, in this report, a new MAC protocol allowing multi-channel allocation for 802.15.4a compliant devices.

  14. Multi channel quantum defect theory calculations of the Rydberg spectra of HCO

    Science.gov (United States)

    Douguet, Nicolas; Orel, Ann

    2014-05-01

    We present a first-principles theoretical study of the photoionization spectra of vibrationally autoionizing Rydberg states converging to excited states of HCO+. The clamped-nuclei scattering matrix, quantum defects parameters and transition dipole moments are explicitly calculated using the complex variational Kohn technique. The multi-channel quantum defect theory and vibrational frame transformation are then used to calculate the absorption spectrum. The results are compared with experimental data on double-resonance spectroscopy of the high Rydberg states of formyl radical. This work is supported by the DOE Office of Basic Energy Science and the National Science Foundation, Grant No's PHY-10-68785 and PHY-11-60611.

  15. Spatial Decision Forests for Glioma Segmentation in Multi-Channel MR Images

    OpenAIRE

    Geremia, Ezequiel; Menze, Bjoern H.; Ayache, Nicholas

    2012-01-01

    International audience; A fully automatic algorithm is presented for the automatic segmentation of gliomas in 3D MR images. It builds on the discriminative random decision forest framework to provide a voxel-wise probabilistic classi cation of the volume. Our method uses multi-channel MR intensi- ties (T1, T1C, T2, Flair), spatial prior and long-range comparisons with 3D regions to discriminate lesions. A symmetry feature is introduced ac- counting for the fact that gliomas tend to develop in...

  16. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic....... The dereverberation performance of the algorithm is evaluated using computer simulations with realistic hearing aid microphone signals including head-related effects. The algorithm is shown to work well with signals reverberated both by synthetic and by measured room impulse responses, achieving improvements...

  17. A Radiation Hard Multi-Channel Digitizer ASIC for Operation in the Harsh Jovian Environment

    Science.gov (United States)

    Aslam, Shahid; Aslam, S.; Akturk, A.; Quilligan, G.

    2011-01-01

    ultimately impact the surface of Europa after the mission is completed. The current JEO mission concept includes a range of instruments on the payload, to monitor dynamic phenomena (such as Io's volcanoes and Jupiters atmosphere), map the Jovian magnetosphere and its interactions with the Galilean satellites, and characterize water oceans beneath the ice shells of Europa and Ganymede. The payload includes a low mass (3.7 Kg) and low power (< 5 W) Thermal Instrument (TI) concept for measuring possible warm thermal anomalies on Europa s cold surface caused by recent (< 10,000 years) eruptive activity. Regions of anomalously high heat flow will be identified by thermal mapping using a nadir pointing, push-broom filter radiometer that provides far-IR imagery in two broad band spectral wavelength regions, 8-20 m and 20-100 m, for surface temperature measurements with better than a 2 K accuracy and a spatial resolution of 250 m/pixel obtained from a 100 Km orbit. The temperature accuracy permits a search for elevated temperatures when combined with albedo information. The spatial resolution is sufficient to resolve Europa's larger cracks and ridge axial valleys. In order to accomplish the thermal mapping, the TI uses sensitive thermopile arrays that are readout by a custom designed low-noise Multi-Channel Digitizer (MCD) ASIC that resides very close to the thermopile linear array outputs. Both the thermopile array and the MCD ASIC will need to show full functionality within the harsh Jovian radiation environment, operating at cryogenic temperatures, typically 150 K to 170 K. In the following, a radiation mitigation strategy together with a low risk Radiation-Hardened-By-Design (RHBD) methodology using commercial foundry processes is given for the design and manufacture of a MCD ASIC that will meet this challenge.

  18. Calculation of BER in multi-channel silicon optical interconnects: comparative analysis of strip and photonic crystal waveguides

    Science.gov (United States)

    You, Jie; Lavdas, Spyros; Panoiu, Nicolae C.

    2016-05-01

    We present an effective approach to evaluate the performance of multi-channel silicon (Si) photonic systems. The system is composed of strip Si photonic waveguides (Si-PhWs) with uniform cross-section or photonic-crystal (PhC) Si waveguides (Si-PhCWs), combined with a set of direct-detection receivers. Moreover, the optical field in each channel is the superposition of a continuous-wave nonreturn-to-zero ON-OFF keying modulated signal and a white Gaussian noise. In order to characterize the optical signal propagation in the waveguides, an accurate mathematical model describing all relevant linear and nonlinear optical effects and its linearized version is employed. In addition, two semi-analytical methods, time- and frequency-domain Karhunen-Loève series expansion, are used to assess the system bit-error-rate (BER). Our analysis reveals that Si-PhCWs provide similar performance as Si-PhWs, but for 100× shorter length. Importantly, much worse BER is achieved in Si-PhCWs when one operates in slow-light regime, due to the enhanced linear and nonlinear effects.

  19. Electron-electron interactions in disordered systems

    CERN Document Server

    Efros, AL

    1985-01-01

    ``Electron-Electron Interactions in Disordered Systems'' deals with the interplay of disorder and the Coulomb interaction. Prominent experts give state-of-the-art reviews of the theoretical and experimental work in this field and make it clear that the interplay of the two effects is essential, especially in low-dimensional systems.

  20. A multi-channel femtoampere-sensitivity conductometric array for biosensing applications.

    Science.gov (United States)

    Gore, Amit; Chakrabartty, Shantanu; Pal, Sudeshna; Alocilja, Evangelyn

    2006-01-01

    Rapid detection of pathogens using field deployable biosensors requires integrated sensing and data processing. Detection of low concentration of biological agents is possible using accurate and real-time signal characterization devices. This paper presents a multi-channel conductometric array that can detect and measure current up to femtoampere range. The architecture uses a novel semi-synchronous SigmaDelta modulation that allows measurement of ultra-small currents by using a hysteretic comparison technique. The architecture achieves higher energy efficiency over a conventional SigmaDelta by reducing the total switching cycles of the comparator. A 3 mm x 3 mm chip implementing a 42 channel potentiostat array has been prototyped in a 0.5 microm CMOS technology. Measured results show 10 bits of resolution, with a sensitivity of upto 50 fA of current. The power consumption of the potentiostat is 11 microW per channel at a sampling rate of 250 kHz. The multi-channel potentiostat has been integrated with a conductometric biosensor for field deployable applications. Results with a Bacillus Cereus based biosensor demonstrate the effectiveness of the potentiostat in characterizing different concentration levels of pathogens in realtime.

  1. Salt intrusion in multi-channel estuaries: a case study in the Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    A. D. Nguyen

    2006-01-01

    Full Text Available There is a well-tested theory for the computation of salt intrusion in alluvial estuaries that is fully analytical and predictive. The theory uses analytical equations to predict the mixing behaviour of the estuary based on measurable quantities, such as channel topography, river discharge and tidal characteristics. It applies to single-channel topographies and estuaries that demonstrate moderate tidal damping. The Mekong delta is a multi-channel estuary where the tide is damped due to a relatively strong river discharge (in the order of 2000 m3/s, even during the dry season. As a result the Mekong is a strongly riverine estuary. This paper aims to test if the theory can be applied to such a riverine multi-channel estuary, and to see if possible adjustments or generalisations need to be made. The paper presents salt intrusion measurements that were done by moving boat in 2005, to which the salt intrusion model was calibrated. The theory has been expanded to cater for tidal damping. Subsequently the model has been validated with observations made at fixed locations over the years 1998 and 1999. Finally it has been tested whether the Mekong calibration fits the overall predictive equations derived in other estuaries. The test has been successful and led to a slight adjustment of the predictive equation to cater for estuaries that experience a sloping bottom.

  2. A Schedule-based Multi-channel MAC Protocol for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Ilyoung Chong

    2010-10-01

    Full Text Available Due to the half-duplex property of the sensor radio and the broadcast nature of wireless medium, limited bandwidth remains a pressing issue for wireless sensor networks (WSNs. The design of multi-channel MAC protocols has attracted the interest of many researchers as a cost effective solution to meet the higher bandwidth demand for the limited bandwidth in WSN. In this paper, we present a scheduled-based multi-channel MAC protocol to improve network performance. In our protocol, each receiving node selects (schedules some timeslot(s, in which it may receive data from the intending sender(s. The timeslot selection is done in a conflict free manner, where a node avoids the slots that are already selected by others in its interference range. To minimize the conflicts during timeslot selection, we propose a unique solution by splitting the neighboring nodes into different groups, where nodes of a group may select the slots allocated to that group only. We demonstrate the effectiveness of our approach thorough simulations in terms of performance parameters such as aggregate throughput, packet delivery ratio, end-to-end delay, and energy consumption.

  3. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  4. Maximizing Networking Capacity in Multi-Channel Multi-Radio Wireless Networks

    Institute of Scientific and Technical Information of China (English)

    万鹏俊; 万志国

    2014-01-01

    Providing each node with one or more multi-channel radios offers a promising avenue for enhancing the network capacity by simultaneously exploiting multiple non-overlapping channels through different radio interfaces and mitigating interferences through proper channel assignment. However, it is quite challenging to effectively utilize multiple channels and/or multiple radios to maximize throughput capacity. The National Natural Science Foundation of China (NSFC) Pro ject 61128005 conducted comprehensive algorithmic-theoretic and queuing-theoretic studies of maximizing wireless networking capacity in multi-channel multi-radio (MC-MR) wireless networks under the protocol interference model and fundamentally advanced the state of the art. In addition, under the notoriously hard physical interference model, this project has taken initial algorithmic studies on maximizing the network capacity, with or without power control. We expect the new techniques and tools developed in this project will have wide applications in capacity planning, resource allocation and sharing, and protocol design for wireless networks, and will serve as the basis for future algorithm developments in wireless networks with advanced features, such as multi-input multi-output (MIMO) wireless networks.

  5. Robust detection of multiple sclerosis lesions from intensity-normalized multi-channel MRI

    Science.gov (United States)

    Karpate, Yogesh; Commowick, Olivier; Barillot, Christian

    2015-03-01

    Multiple sclerosis (MS) is a disease with heterogeneous evolution among the patients. Quantitative analysis of longitudinal Magnetic Resonance Images (MRI) provides a spatial analysis of the brain tissues which may lead to the discovery of biomarkers of disease evolution. Better understanding of the disease will lead to a better discovery of pathogenic mechanisms, allowing for patient-adapted therapeutic strategies. To characterize MS lesions, we propose a novel paradigm to detect white matter lesions based on a statistical framework. It aims at studying the benefits of using multi-channel MRI to detect statistically significant differences between each individual MS patient and a database of control subjects. This framework consists in two components. First, intensity standardization is conducted to minimize the inter-subject intensity difference arising from variability of the acquisition process and different scanners. The intensity normalization maps parameters obtained using a robust Gaussian Mixture Model (GMM) estimation not affected by the presence of MS lesions. The second part studies the comparison of multi-channel MRI of MS patients with respect to an atlas built from the control subjects, thereby allowing us to look for differences in normal appearing white matter, in and around the lesions of each patient. Experimental results demonstrate that our technique accurately detects significant differences in lesions consequently improving the results of MS lesion detection.

  6. A Multi-Channel Salience Based Detail Exaggeration Technique for 3D Relief Surfaces

    Institute of Scientific and Technical Information of China (English)

    Yong-Wei Miao; Jie-Qing Feng; Jin-Rong Wang; Renato Pajarola

    2012-01-01

    Visual saliency can always persuade the viewer's visual attention to fine-scale mesostructure of 3D complex shapes.Owing to the multi-channel salience measure and salience-domain shape modeling technique,a novel visual saliency based shape depiction scheme is presented to exaggerate salient geometric details of the underlying relief surface.Our multi-channel salience measure is calculated by combining three feature maps,i.e.,the O-order feature map of local height distribution,the 1-order feature map of normal difference,and the 2-order feature map of mean curvature variation.The original relief surface is firstly manipulated by a salience-domain enhancement function,and the detail exaggeration surface can then be obtained by adjusting the surface normals of the original surface as the corresponding final normals of the manipulated surface.The advantage of our detail exaggeration technique is that it can adaptively alter the shading of the original shape to reveal visually salient features whilst keeping the desired appearance unimpaired.The experimental results demonstrate that our non-photorealistic shading scheme can enhance the surface mesostructure effectively and thus improving the shape depiction of the relief surfaces.

  7. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-01-01

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise. PMID:28273818

  8. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  9. A multi-channel fully differential programmable integrated circuit for neural recording application

    Science.gov (United States)

    Yun, Gui; Xu, Zhang; Yuan, Wang; Ming, Liu; Weihua, Pei; Kai, Liang; Suibiao, Huang; Bin, Li; Hongda, Chen

    2013-10-01

    A multi-channel, fully differential programmable chip for neural recording application is presented. The integrated circuit incorporates eight neural recording amplifiers with tunable bandwidth and gain, eight 4th-order Bessel switch capacitor filters, an 8-to-1 analog time-division multiplexer, a fully differential successive approximation register analog-to-digital converter (SAR ADC), and a serial peripheral interface for communication. The neural recording amplifier presents a programmable gain from 53 dB to 68 dB, a tunable low cut-off frequency from 0.1 Hz to 300 Hz, and 3.77 μVrms input-referred noise over a 5 kHz bandwidth. The SAR ADC digitizes signals at maximum sampling rate of 20 kS/s per channel and achieves an ENOB of 7.4. The integrated circuit is designed and fabricated in 0.18-μm CMOS mix-signal process. We successfully performed a multi-channel in-vivo recording experiment from a rat cortex using the neural recording chip.

  10. Cross contrast multi-channel image registration using image synthesis for MR brain images.

    Science.gov (United States)

    Chen, Min; Carass, Aaron; Jog, Amod; Lee, Junghoon; Roy, Snehashis; Prince, Jerry L

    2017-02-01

    Multi-modal deformable registration is important for many medical image analysis tasks such as atlas alignment, image fusion, and distortion correction. Whereas a conventional method would register images with different modalities using modality independent features or information theoretic metrics such as mutual information, this paper presents a new framework that addresses the problem using a two-channel registration algorithm capable of using mono-modal similarity measures such as sum of squared differences or cross-correlation. To make it possible to use these same-modality measures, image synthesis is used to create proxy images for the opposite modality as well as intensity-normalized images from each of the two available images. The new deformable registration framework was evaluated by performing intra-subject deformation recovery, intra-subject boundary alignment, and inter-subject label transfer experiments using multi-contrast magnetic resonance brain imaging data. Three different multi-channel registration algorithms were evaluated, revealing that the framework is robust to the multi-channel deformable registration algorithm that is used. With a single exception, all results demonstrated improvements when compared against single channel registrations using the same algorithm with mutual information.

  11. Adaptive spatio-temporal filtering of disturbed ECGs: a multi-channel approach to heartbeat detection in smart clothing.

    Science.gov (United States)

    Wiklund, Urban; Karlsson, Marcus; Ostlund, Nils; Berglin, Lena; Lindecrantz, Kaj; Karlsson, Stefan; Sandsjö, Leif

    2007-06-01

    Intermittent disturbances are common in ECG signals recorded with smart clothing: this is mainly because of displacement of the electrodes over the skin. We evaluated a novel adaptive method for spatio-temporal filtering for heartbeat detection in noisy multi-channel ECGs including short signal interruptions in single channels. Using multi-channel database recordings (12-channel ECGs from 10 healthy subjects), the results showed that multi-channel spatio-temporal filtering outperformed regular independent component analysis. We also recorded seven channels of ECG using a T-shirt with textile electrodes. Ten healthy subjects performed different sequences during a 10-min recording: resting, standing, flexing breast muscles, walking and pushups. Using adaptive multi-channel filtering, the sensitivity and precision was above 97% in nine subjects. Adaptive multi-channel spatio-temporal filtering can be used to detect heartbeats in ECGs with high noise levels. One application is heartbeat detection in noisy ECG recordings obtained by integrated textile electrodes in smart clothing.

  12. Comprehensive multi-channel multi-dimensional counter-current chromatography for separation of tanshinones from Salvia miltiorrhiza Bunge.

    Science.gov (United States)

    Meng, Jie; Yang, Zhi; Liang, Junling; Zhou, Hui; Wu, Shihua

    2014-01-03

    Multi-dimensional chromatography offers the increased resolution and peak capacity by coupling of multiple columns with the same or different separation mechanisms. In this work, a novel multi-channel multi-dimensional counter-current chromatography (CCC) has been successfully constructed and used for several two-dimensional (2D) and three-dimensional (3D) CCC separations including 2D A×B/A×C, A×B-C and A-B×C, and 3D A×B×C systems. These 2D and 3D CCC systems were further applied to separate the bioactive tanshinones from the extract of Tanshen (or Danshen, Salvia miltiorrhiza Bunge), a famous Traditional Chinese Medicine (TCM). As a result, the developed 2D and 3D CCC methods were successful and efficient for resolving the tanshinones from complex extracts. Compared to the 1D multiple columns CCC separation, the 2D and 3D CCC decrease analysis time, reduce solvent consumption and increase sample throughput significantly. It may be widely used for current drug development, metabolomic analysis and natural product isolation.

  13. An Empirical Study of UDP (CBR) Packet Performance over AODV Single & Multi-Channel Parallel Transmission in MANET

    CERN Document Server

    Morshed, Md Monzur; Islam, Md Rafiqul

    2011-01-01

    Mobile Ad-hoc Network is a temporary network which is the cooperative engagement of a collection of standalone mobile nodes that are not connected to any external network. It is a decentralized network where mobile nodes can be easily deployed in almost any environment without sophisticated infrastructure support. An empirical study has been done for AODV routing protocol under single channel and multi channel environment using the tool NS2. To compare the performance of AODV in the two environments, the simulation results have been analyzed by graphical manner and trace file based on QoS metrics such as throughput, packet drop, delay and jitter. The simulation result analysis verifies the AODV routing protocol performances for single channel and multi channel. After the analysis of the simulation scenario we suggest that use of Parallel MAC (P-MAC) may enhance the performance for multi channel.

  14. An efficient VLSI implementation of on-line recursive ICA processor for real-time multi-channel EEG signal separation.

    Science.gov (United States)

    Shih, Wei-Yeh; Liao, Jui-Chieh; Huang, Kuan-Ju; Fang, Wai-Chi; Cauwenberghs, Gert; Jung, Tzyy-Ping

    2013-01-01

    This paper presents an efficient VLSI implementation of on-line recursive ICA (ORICA) processor for real-time multi-channel EEG signal separation. The proposed design contains a system control unit, a whitening unit, a singular value decomposition unit, a floating matrix multiply unit and, and an ORICA weight training unit. Because the input sample rate of the ORICA processor is 128 Hz, the ORICA processor should produce independent components before the next sample is input in 1/128 s. Under the timing constraints of commutating multi-channel ORICA in real time, the design of the ORICA processor is a mixed architecture, which is designed as different hardware parallelism according to the complexity of processing units. The shared arithmetic processing unit and shared register can reduce hardware complexity and power consumption. The proposed design is implemented used TSMC 90 nm CMOS technology with 8-channel EEG processing in 128 Hz sample rate of raw data and consumes 2.827 mW at 50 MHz clock rate. The performance of the proposed design is also shown to reach 0.0078125 s latency after each EEG sample time, and the average correlation coefficient between the original source signals and extracted ORICA signals for each 1 s frame is 0.9763.

  15. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2013-06-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  16. A Multi-Channel Method for Retrieving Surface Temperature for High-Emissivity Surfaces from Hyperspectral Thermal Infrared Images

    Directory of Open Access Journals (Sweden)

    Xinke Zhong

    2015-06-01

    Full Text Available The surface temperature (ST of high-emissivity surfaces is an important parameter in climate systems. The empirical methods for retrieving ST for high-emissivity surfaces from hyperspectral thermal infrared (HypTIR images require spectrally continuous channel data. This paper aims to develop a multi-channel method for retrieving ST for high-emissivity surfaces from space-borne HypTIR data. With an assumption of land surface emissivity (LSE of 1, ST is proposed as a function of 10 brightness temperatures measured at the top of atmosphere by a radiometer having a spectral interval of 800–1200 cm−1 and a spectral sampling frequency of 0.25 cm−1. We have analyzed the sensitivity of the proposed method to spectral sampling frequency and instrumental noise, and evaluated the proposed method using satellite data. The results indicated that the parameters in the developed function are dependent on the spectral sampling frequency and that ST of high-emissivity surfaces can be accurately retrieved by the proposed method if appropriate values are used for each spectral sampling frequency. The results also showed that the accuracy of the retrieved ST is of the order of magnitude of the instrumental noise and that the root mean square error (RMSE of the ST retrieved from satellite data is 0.43 K in comparison with the AVHRR SST product.

  17. All-optical multi-channel wavelength conversion of Nyquist 16 QAM signal using a silicon waveguide.

    Science.gov (United States)

    Long, Yun; Liu, Jun; Hu, Xiao; Wang, Andong; Zhou, Linjie; Zou, Kaiheng; Zhu, Yixiao; Zhang, Fan; Wang, Jian

    2015-12-01

    We experimentally demonstrate on-chip all-optical multi-channel wavelength conversion of Nyquist 16 ary quadrature amplitude modulation (16 QAM) signal in a silicon waveguide. The measured optical signal-to-noise ratio (OSNR) penalties of wavelength conversion are ∼2  dB. The observed constellations of converted idlers indicate favorable performance of silicon-waveguide-based multi-channel wavelength conversion. We also experimentally study and compare the phase-conjugated wavelength conversion by degenerate four-wave mixing (FWM) and transparent wavelength conversion by non-degenerate FWM in the silicon waveguide.

  18. Disordered strongly correlated electronic systems

    Science.gov (United States)

    Javan Mard, Hossein

    Disorder can have a vast variety of consequences for the physics of phase transitions. Some transitions remain unchanged in the presence of disorder while others are completely destroyed. In this dissertation we study the effects of quenched disorder on electronic systmens at zero temperature. First, we perform variational studies of the interaction-localization problem to describe the interaction-induced renormalizations of the effective (screened) random potential seen by quasiparticles. Here we present results of careful finite-size scaling studies for the conductance of disordered Hubbard chains at half-filling and zero temperature. While our results indicate that quasiparticle wave functions remain exponentially localized even in the presence of moderate to strong repulsive interactions, we show that interactions produce a strong decrease of the characteristic conductance scale g* signaling the crossover to strong localization. This effect, which cannot be captured by a simple renormalization of the disorder strength, instead reflects a peculiar non-Gaussian form of the spatial correlations of the screened disordered potential, a hitherto neglected mechanism to dramatically reduce the impact of Anderson localization (interference) effects. Second, we formulate a strong-disorder renormalization-group (SDRG) approach to study the beta function of the tight-binding model in one dimension with both diagonal and off-diagonal disorder for states at the band center. We show that the SDRG method, when used to compute transport properties, yields exact results since it is identical to the transfer matrix method. The beta function is shown to be universal when only off-diagonal disorder is present even though single-parameter scaling is known to be violated. A different single-parameter scaling theory is formulated for this particular (particle-hole symmetric) case. Upon breaking particle-hole symmetry (by adding diagonal disorder), the beta function is shown to

  19. Localization in disordered systems with interactions

    Indian Academy of Sciences (India)

    Angus MacKinnon

    2008-02-01

    We present an improved numerical approach to the study of disorder and interactions in quasi-1D systems which combines aspects of the transfer matrix method and the density matrix renormalization group which have been successfully applied to disorder and interacting problems respectively. The method is applied to spinless fermions in 1D and a generalization to finite cross-sections is outlined.

  20. Analysis Of The Extrusion Process Of A Square Tube Multi-Channel Heat Pipe

    Directory of Open Access Journals (Sweden)

    Kim K.S.

    2015-06-01

    Full Text Available Heat pipes have been recently in use for cooling purposes in various fields, including electronic circuit boards and vehicle parts that generate large amounts of heat. In order to minimize the loss of heat transferred, there is a need to maximize the contact area of the working fluid. This study produced a square tube multi-channel heat pipe to replace the existing circular pipe type to maximize the internal surface area thereof. This expands the surface, allowing the working fluid to come into contact with a wider area and enhancing thermal radiation performance. A mold for the production for such a product was designed, and finite element simulation was performed to determine whether production is possible.

  1. Note: Multi channel Doppler tuned spectrometer to study highly charged ions.

    Science.gov (United States)

    Karn, Ranjeet K; Mishra, C N; Ahmad, Nissar; Saini, S K; Safvan, C P; Nandi, T

    2014-06-01

    We describe the design and implementation of a multi channel Doppler tuned spectrometer setup to study physics of highly charged ions at high resolution in a direct way. A unique Soller slit assembly coupled with a long one dimensional position sensitive proportional counter enables us to get distinct x-ray peaks at different angles, which allows us to cover large number of angle in one shot. By using this setup, 1s2s (3)S1 - 1s(2) (1)S0 M1 transition in He-like Fe has been resolved from its satellite line 1s2s2p ⁴P(5/2)⁰ - 1s(2)2s (2)S(1/2) M2 transition in Li-like Fe and measured the lifetime of their respective upper levels with high precision.

  2. Multi-channel front-end board for SiPM readout

    Science.gov (United States)

    Auger, M.; Ereditato, A.; Goeldi, D.; Kreslo, I.; Lorca, D.; Luethi, M.; von Rohr, C. Rudolf; Sinclair, J.; Weber, M. S.

    2016-10-01

    We describe a novel high-speed front-end electronic board (FEB) for interfacing an array of 32 Silicon Photo-multipliers (SiPM) with a computer. The FEB provides individually adjustable bias for the SiPMs, and performs low-noise analog signal amplification, conditioning and digitization. It provides event timing information accurate to 1.3 ns RMS. The signal-to-noise ratio of 12 is attained for the first photo-electron peak. The back-end data interface is realized on the basis of 100 Mbps Ethernet. The design allows daisy-chaining of up to 256 units into one network interface, thus enabling compact and efficient readout schemes for multi-channel scintillating detectors, using SiPMs as photo-sensors.

  3. Multi-Channel Three-Dimensional SOLA Inversion for Local Helioseismology

    CERN Document Server

    Jackiewicz, J; Gizon, L; Hanasoge, S M; Hohage, T; Ruffio, J -B; Svanda, M

    2011-01-01

    Inversions for local helioseismology are an important and necessary step for obtaining three-dimensional maps of various physical quantities in the solar interior. Frequently, the full inverse problems that one would like to solve prove intractable because of computational constraints. Due to the enormous seismic data sets that already exist and those forthcoming, this is a problem that needs to be addressed. To this end, we present a very efficient linear inversion algorithm for local helioseismology. It is based on a subtractive optimally localized averaging (SOLA) scheme in the Fourier domain, utilizing the horizontal-translation invariance of the sensitivity kernels. In Fourier space the problem decouples into many small problems, one for each horizontal wave vector. This multi-channel SOLA method is demonstrated for an example problem in time-distance helioseismology that is small enough to be solved both in real and Fourier space. We find that both approaches are successful in solving the inverse proble...

  4. Design of a novel multi channel photonic crystal fiber polarization beam splitter

    Science.gov (United States)

    Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun

    2017-10-01

    A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.

  5. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    , and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  6. The interaction between room and musical instruments studied by multi-channel auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    in the anechoic recording. With this technique the variations in sound radiation from the musical instrument during the performance e.g. due to changes in level or movements can be reproduced with the influence of the surrounding room surfaces. Examples include a grand piano and a clarinet.......The directivity of musical instruments is very complicated and typically changes from one tone to the next. So, instead of measuring the average directivity, a multi-channel auralization method has been developed, which allows a highly accurate and realistic sounding auralization of musical...... instruments in rooms. Anechoic recordings have been made with 5 and 13 evenly distributed microphones around the musical instrument. The reproduction is made with a room acoustics simulation software using a compound source, which is in fact a number of highly directive sources, one for each of the channels...

  7. Integrated multi-channel receiver for a pulsed time-of-flight laser radar

    Science.gov (United States)

    Jiang, Yan; Liu, Ruqing; Zhu, Jingguo

    2015-04-01

    An integrated multi-channel receiver for a pulsed time-of-flight (TOF) laser rangefinder has been designed in this paper. The receiver chip as an important component of the laser radar device has been implemented in a 0.18um CMOS process. It consists of sixteen channels and every channel includes preamplifier, amplifier stages, high-pass filter and a timing discriminator which contains a timing comparator and a noise comparator. Each signal paths is independent of other channels. Based on the simulations, the bandwidth and transimpedance of the amplifier channel are 652MHz, 99dBΩ. Under the simulation condition of TT corner and 27°C, the propagation delay of the discriminator is 2.15ns and the propagation delay dispersion is 223ps. The power consumption during continuous measurement is 810mW, and the operating temperature range of the device is -10~60°C.

  8. Multi-channel front-end board for SiPM readout

    CERN Document Server

    Auger, M; Goeldi, D; Kreslo, I; Lorca, D; Luethi, M; von Rohr, C Rudolf; Sinclair, J; Weber, M S

    2016-01-01

    We describe a novel high-speed front-end electronic board (FEB) for interfacing an array of 32 Silicon Photo-multipliers (SiPM) with a computer. The FEB provides individually adjustable bias on the SiPMs, and performs low-noise analog signal amplification, conditioning and digitization. It provides event timing information accurate to 1.3 ns RMS. The back-end data interface is realized on the basis of 100 Mbps Ethernet. The design allows daisy-chaining of up to 256 units into one network interface, thus enabling compact and efficient readout schemes for multi-channel scintillating detectors, using SiPMs as photo-sensors.

  9. A Multi-Channel Diversity Based MAC Protocol for Power-Constrained Cognitive Ad Hoc Networks

    CERN Document Server

    Wang, Yichen; Du, Qinghe; Zhang, Chao

    2011-01-01

    One of the major challenges in the medium access control (MAC) protocol design over cognitive Ad Hoc networks (CAHNs) is how to efficiently utilize multiple opportunistic channels, which vary dynamically and are subject to limited power resources. To overcome this challenge, in this paper we first propose a novel diversity technology called \\emph{Multi-Channel Diversity} (MCD), allowing each secondary node to use multiple channels simultaneously with only one radio per node under the upperbounded power. Using the proposed MCD, we develop a MCD based MAC (MCD-MAC) protocol, which can efficiently utilize available channel resources through joint power-channel allocation. Particularly, we convert the joint power-channel allocation to the Multiple-Choice Knapsack Problem, such that we can obtain the optimal transmission strategy to maximize the network throughput through dynamic programming. Simulation results show that our proposed MCD-MAC protocol can significantly increase the network throughput as compared to...

  10. Multi-Photon Multi-Channel Interferometry for Quantum Information Processing

    CERN Document Server

    Dhand, Ish

    2016-01-01

    This thesis reports advances in the theory of design, characterization and simulation of multi-photon multi-channel interferometers. I advance the design of interferometers through an algorithm to realize an arbitrary discrete unitary transformation on the combined spatial and internal degrees of freedom of light. This procedure effects an arbitrary $n_{s}n_{p}\\times n_{s}n_{p}$ unitary matrix on the state of light in $n_{s}$ spatial and $n_{p}$ internal modes. I devise an accurate and precise procedure for characterizing any multi-port linear optical interferometer using one- and two-photon interference. Accuracy is achieved by estimating and correcting systematic errors that arise due to spatiotemporal and polarization mode mismatch. Enhanced accuracy and precision are attained by fitting experimental coincidence data to a curve simulated using measured source spectra. The efficacy of our characterization procedure is verified by numerical simulations. I develop group-theoretic methods for the analysis and ...

  11. Enhancing the Linear Dynamic Range in Multi-Channel Single Photon Detector beyond 7OD

    Science.gov (United States)

    Gudkov, Dmytro; Gudkov, George; Gorbovitski, Boris; Gorfinkel, Vera

    2015-01-01

    We present design, implementation, and characterization of a single photon detector based on 32-channel PMT sensor [model H7260-20, Hamamatsu]. The developed high speed electronics enables the photon counting with linear dynamic range (LDR) up to 108count/s per detector's channel. The experimental characterization and Monte-Carlo simulations showed that in the single photon counting mode the LDR of the PMT sensor is limited by (i) “photon” pulse width (current pulse) of 900ps and (ii) substantial decrease of amplitudes of current pulses for count rates exceeding 108 count/s. The multi-channel architecture of the detector and the developed firm/software allow further expansion of the dynamic range of the device by 32-fold by using appropriate beam shaping. The developed single photon counting detector was tested for the detection of fluorescence labeled microbeads in capillary flow. PMID:27087788

  12. Multi-channel far-infrared HL-2A interferometer-polarimeter.

    Science.gov (United States)

    Zhou, Y; Deng, Z C; Li, Y G; Yi, J

    2012-10-01

    An HL-2A interferometer is upgraded to a multi-channel interferometer∕polarimeter, which includes four chords for the interferometer and four chords for the polarimeter. The far-infrared lasers (at λ = 432.5 μm and 30 mW power) are used to probe plasmas horizontally in the midplane of HL-2A. A conventional heterodyne technique is used for the interferometer. Two counter-rotating circularly polarized waves are used to measure the Faraday rotation effect. A fast-phase comparator with temporal resolution of 1 μs and phase resolution 0.1° is developed. Further, the distortion of the polarization caused by the beam-splitters and the other optical components is also investigated.

  13. Multi-channel far-infrared HL-2A interferometer-polarimetera)

    Science.gov (United States)

    Zhou, Y.; Deng, Z. C.; Li, Y. G.; Yi, J.

    2012-10-01

    An HL-2A interferometer is upgraded to a multi-channel interferometer/polarimeter, which includes four chords for the interferometer and four chords for the polarimeter. The far-infrared lasers (at λ = 432.5 μm and 30 mW power) are used to probe plasmas horizontally in the midplane of HL-2A. A conventional heterodyne technique is used for the interferometer. Two counter-rotating circularly polarized waves are used to measure the Faraday rotation effect. A fast-phase comparator with temporal resolution of 1 μs and phase resolution 0.1° is developed. Further, the distortion of the polarization caused by the beam-splitters and the other optical components is also investigated.

  14. Telephone speech enhancement for hearing-impaired listeners using multi-channel compression

    Science.gov (United States)

    Natarajan, Harikrishna P.; Krishnamurthy, Ashok K.; Feth, Lawrence L.

    2002-05-01

    Elderly listeners with sensorineural hearing impairment usually have difficulty with telephone communication if they do not use a hearing aid or telephone amplifier. In many cases, these devices may not be readily available or maybe uncomfortable to use. We describe here an alternative strategy to enhance the speech by pre-processing the signal before sending it over the telephone line. The pre-processing is based on a multi-channel compression algorithm that modifies the critical band spectrum of the speech signal to bring it within the dynamic hearing range of the listener, while also compensating for the effects of the telephone line. We describe the algorithm and the results of a simulation study in which the Articulation Index (AI) is used to measure the intelligibility enhancement, and the Glasberg, Moore and Stone (1999) model is used to simulate the effects of the hearing loss.

  15. First results of FGLD gas detector with multi-channel self-triggering readout electronics

    CERN Document Server

    Dick, Louis; De Oliveira, R; Watts, D

    2007-01-01

    Following the successful demonstration of a proof-of-concept FGLD detector, work has been done to find a multi-channel readout electronics capable of obtaining the position information from its 3-axis geometry and suitable for medical imaging applications. The IDEAS GP3 and GP5 chips were selected for testing because they are sensitive to the range of input charge collected on the FGLD and because they are self-triggering. Preliminary tests in which both the GP3 and GP5 were connected to the ground layer of the FGLD has yielded promising results. Signals can be seen in the analysis software and some initial results of the charge sharing between strips is presented. Furthermore, both chips were subjected to forced discharging. Only a few input channels localized about the discharge were destroyed in the GP3 whereas the GP5 continued to function normally after repeated discharges.

  16. Quantum and quasiclassical dynamics of the multi-channel H + H2S reaction

    Science.gov (United States)

    Qi, Ji; Lu, Dandan; Song, Hongwei; Li, Jun; Yang, Minghui

    2017-03-01

    The prototypical multi-channel reaction H + H2S → H2 + SH/H + H2S has been investigated using the full-dimensional quantum scattering and quasi-classical trajectory methods to unveil the underlying competition mechanism between different product channels and the mode specificity. This reaction favors the abstraction channel over the exchange channel. For both channels, excitations in the two stretching modes promote the reaction with nearly equal efficiency and are more efficient than the bending mode excitation. However, they are all less efficient than the translational energy. In addition, the experimentally observed non-Arrhenius temperature dependence of the thermal rate constants is reasonably reproduced by the quantum dynamics calculations, confirming that the non-Arrhenius behavior is caused by the pronounced quantum tunneling.

  17. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    ) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between...... a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......, subjects could only discern differences between the orchestra configurations with the five-channel multi-source auralizations. Overall, the multi-source auralization technique was found to be an effective method for creating realistic orchestra auralizations, but using multichannel anechoic recordings...

  18. Rayleigh waves ellipticity and mode mis-identification in multi-channel analysis of surface waves

    DEFF Research Database (Denmark)

    Boaga, Jacopo; Cassiani, Giorgio; Strobbia, Claudio

    dispersion curve which is then inverted. Typically, single component vertical and multi channel receivers are used. In most cases the inversion of the dispersion properties is carried out assuming that the experimental dispersion curve corresponds to a single mode, mostly the fundamental Rayleigh mode......-identification known as ‘osculation’ (‘kissing’). In general it is called ‘osculation point’ the point where the energy peak shifts at low frequencies from the fundamental to the first higher mode. This jump occurs, with a continuous smooth transition, around a well-define frequency where the two modes get very close...... the vertical component of ground motion, as the mode osculation is linked to the Rayleigh wave ellipticity polarization, and therefore we conclude that multi-component data, using also horizontal receivers, can help discern the multi-modal nature of surface waves. Finally we introduce a-priori detectors...

  19. Joint Reconstruction of Multi-channel, Spectral CT Data via Constrained Total Nuclear Variation Minimization

    CERN Document Server

    Rigie, David

    2014-01-01

    We explore the use of the recently proposed "total nuclear variation" (TNV) \\cite{Rigie2014,Holt2014} as a regularizer for reconstructing multi-channel, spectral CT images. This convex penalty is a natural extension of the total variation (TV) to vector-valued images and has the advantage of encouraging common edge locations and a shared gradient direction among image channels. We show how it can be incorporated into a general, data-constrained reconstruction framework and derive update equations based on the first-order, primal-dual algorithm of Chambolle and Pock. Early simulation studies based on the numerical XCAT phantom indicate that the inter-channel coupling introduced by the TNV leads to better preservation of image features at high levels of regularization, compared to independent, channel-by-channel TV reconstructions.

  20. Scale-Free Brain Quartet: Artistic Filtering of Multi-Channel Brainwave Music

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective. PMID:23717527

  1. Scale-free brain quartet: artistic filtering of multi-channel brainwave music.

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective.

  2. Multi-channel non-return-to-zero format to return-to-zero format conversion with duplicate output

    Science.gov (United States)

    Yu, Yu; Zhang, Xinliang; Huang, Dexiu

    2010-12-01

    We demonstrate multi-channel regenerative non-return-to-zero (NRZ) to return-to-zero (RZ) conversions with tunable output pulse-width and single-to-dual function, using a phase modulator and an array waveguide grating (AWG). Transmission and bit error ratio (BER) show a good performance for the converted RZ signal compared with conventional one.

  3. Surface Clutter Suppression Techniques Applied to P-band Multi-Channel SAR Ice Sounder Data from East Antarctica

    DEFF Research Database (Denmark)

    Lin, Chung-Chi; Bekaert, David; Gebert, Nicolas

    ., Lausanne, developed and built the radiator-elements of the enhanced POLARIS. Several datasets were acquired in the multi-channel configuration during the Feb. 2011 campaign over East Antarctica. The POLARIS instrument will be briefly introduced, followed by an overview of the sounding campaign. Finally...

  4. Relaxation time in disordered molecular systems

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rodrigo P. [Departamento de Física, Universidade Federal de Santa Catarina, 88040-900 Florianópolis-SC (Brazil); Freire, José A., E-mail: jfreire@fisica.ufpr.br [Departamento de Física, Universidade Federal do Paraná, 81531-990 Curitiba-PR (Brazil)

    2015-05-28

    Relaxation time is the typical time it takes for a closed physical system to attain thermal equilibrium. The equilibrium is brought about by the action of a thermal reservoir inducing changes in the system micro-states. The relaxation time is intuitively expected to increase with system disorder. We derive a simple analytical expression for this dependence in the context of electronic equilibration in an amorphous molecular system model. We find that the disorder dramatically enhances the relaxation time but does not affect its independence of the nature of the initial state.

  5. Mood Disorders in Systemic Lupus Erythematosus

    DEFF Research Database (Denmark)

    Hanly, John G; Su, Li; Urowitz, Murray B

    2015-01-01

    OBJECTIVE: To examine the frequency, characteristics, and outcome of mood disorders, as well as clinical and autoantibody associations, in a multiethnic/racial, prospective inception cohort of patients with systemic lupus erythematosus (SLE). METHODS: Patients were assessed annually for mood...... disorders (4 types, according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition) and 18 other neuropsychiatric events. Global disease activity scores (SLE Disease Activity Index 2000 [SLEDAI-2K]), damage scores (Systemic Lupus International Collaborating Clinics/American College...... time. The lack of association with global SLE disease activity, cumulative organ damage, and lupus autoantibodies emphasizes the multifactorial etiology of mood disorders and a role for non-lupus-specific therapies....

  6. Multi-channel FURLS algorithm for active noise control and simulation%多通道FURLS噪声主动控制算法及仿真

    Institute of Scientific and Technical Information of China (English)

    浦玉学; 张方

    2012-01-01

    In order to improve the slow convergence speed shortcomings of LMS algorithm in active broadband noise control in space and eliminate the influence of sound feedback to the stability of the system, this paper combined RLS algorithm with adaptive filter U structure,put forward the Multichannel Filtering-URLS (MFURLS) algorithm and offered a detailed process of this algorithm. This paper designed a basic multi channel noise control system,and made control simulation with fixed frequency noise and broadband noise,comparing with the multi-channel filtering-ULMS (MFULMS) algorithm. The result shows that the MFURLS algorithm system has about 30 dB noise reduction, and the convergence speed is better than the FULMS algorithm. It proves the MFULMS algorithm has great advantage in broadband noise control.%为了改善最小均方(LMS)类算法在空间宽带噪声主动控制问题中收敛速度慢的缺点,消除声反馈对系统稳定性的影响.将快速收敛的最小二乘(RLS)类算法与自适应滤波U形结构结合,提出多通道滤波-URLS(MFURLS)算法,理论上推导该算法详细流程.本文对定频和宽带噪声进行了降噪仿真,将MFURLS算法与多通道滤波-ULMS(MFULMS)算法进行对比,仿真结果表明采用MFURLS算法的系统有30dB左右的降噪量,且收敛速度优于FULMS算法,证明该算法在宽带噪声控制方面具有很大优势.

  7. Investigation of verbal and visual working memory by multi-channel time-resolved functional near-infrared spectroscopy

    Science.gov (United States)

    Contini, D.; Caffini, M.; Re, R.; Zucchelli, L.; Spinelli, L.; Basso Moro, S.; Bisconti, S.; Ferrari, M.; Quaresima, V.; Cutini, S.; Torricelli, A.

    2013-03-01

    Working memory (WM) is fundamental for a number of cognitive processes, such as comprehension, reasoning and learning. WM allows the short-term maintenance and manipulation of the information selected by attentional processes. The goal of this study was to examine by time-resolved fNIRS neural correlates of the verbal and visual WM during forward and backward digit span (DF and DB, respectively) tasks, and symbol span (SS) task. A neural dissociation was hypothesised between the maintenance and manipulation processes. In particular, a dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) recruitment was expected during the DB task, whilst a lateralised involvement of Brodmann Area (BA) 10 was expected during the execution of the DF task. Thirteen subjects were monitored by a multi-channel, dual-wavelength (690 and 829 nm) time-resolved fNIRS system during 3 minutes long DF and DB tasks and 4 minutes long SS task. The participants' mean memory span was calculated for each task: DF: 6.46+/-1.05 digits; DB: 5.62+/-1.26 digits; SS: 4.69+/-1.32 symbols. No correlation was found between the span level and the heart rate data (measured by pulse oximeter). As expected, DB elicited a broad activated area, in the bilateral VLPFC and the right DLPFC, whereas a more localised activation was observed over the right hemisphere during either DF (BA 10) or SS (BA 10 and 44). The robust involvement of the DLPFC during DB, compared to DF, is compatible with previous findings and with the key role of the central executive subserving in manipulating processes.

  8. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

    Science.gov (United States)

    Córcoles, Juan; Zastrow, Earl; Kuster, Niels

    2017-06-01

    The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

  9. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Amgad

    2012-07-18

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N{sub 2}, Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  10. Simultaneous multi-channel CMW-band and MMW-band UWB monocycle pulse generation using FWM effect in a highly nonlinear photonic crystal fiber.

    Science.gov (United States)

    Zhang, Fangzheng; Wu, Jian; Fu, Songnian; Xu, Kun; Li, Yan; Hong, Xiaobin; Shum, Ping; Lin, Jintong

    2010-07-19

    We propose and experimentally demonstrate a scheme to simultaneously realize multi-channel centimeter wave (CMW) band and millimeter wave (MMW) band ultra-wideband (UWB) monocycle pulse generation using four wave mixing (FWM) effect in a highly nonlinear photonic crystal fiber (HNL-PCF). Two lightwaves carrying polarity-reversed optical Gaussian pulses with appropriate time delay and another lightwave carrying a 20 GHz clock signal are launched into the HNL-PCF together. By filtering out the FWM idlers, two CMW-band UWB monocycle signals and two MMW-band UWB monocycle signals at 20 GHz are obtained simultaneously. Experimental measurements of the generated UWB monocycle pulses at individual wavelength, which comply with the FCC regulations, verify the feasibility and flexibility of proposed scheme for use in practical UWB communication systems.

  11. Random walks, random fields, and disordered systems

    CERN Document Server

    Černý, Jiří; Kotecký, Roman

    2015-01-01

    Focusing on the mathematics that lies at the intersection of probability theory, statistical physics, combinatorics and computer science, this volume collects together lecture notes on recent developments in the area. The common ground of these subjects is perhaps best described by the three terms in the title: Random Walks, Random Fields and Disordered Systems. The specific topics covered include a study of Branching Brownian Motion from the perspective of disordered (spin-glass) systems, a detailed analysis of weakly self-avoiding random walks in four spatial dimensions via methods of field theory and the renormalization group, a study of phase transitions in disordered discrete structures using a rigorous version of the cavity method, a survey of recent work on interacting polymers in the ballisticity regime and, finally, a treatise on two-dimensional loop-soup models and their connection to conformally invariant systems and the Gaussian Free Field. The notes are aimed at early graduate students with a mod...

  12. The human histaminergic system in neuropsychiatric disorders.

    Science.gov (United States)

    Shan, Ling; Bao, Ai-Min; Swaab, Dick F

    2015-03-01

    Histaminergic neurons are exclusively located in the hypothalamic tuberomamillary nucleus, from where they project to many brain areas. The histaminergic system is involved in basic physiological functions, such as the sleep-wake cycle, energy and endocrine homeostasis, sensory and motor functions, cognition, and attention, which are all severely affected in neuropsychiatric disorders. Here, we present recent postmortem findings on the alterations in this system in neuropsychiatric disorders, including Parkinson's disease (PD), Alzheimer's disease (AD), Huntington's disease (HD), depression, and narcolepsy. In addition, we highlight the need to validate animal models for these diseases and also for Tourette's syndrome (TS) in relation to alterations in the histaminergic system. Moreover, we discuss the potential for, and concerns over, the use of novel histamine 3 receptor (H3R) antagonists/inverse agonists as treatment for such disorders.

  13. Laser puncture therapy of nervous system disorders

    Energy Technology Data Exchange (ETDEWEB)

    Anishchenko, G.; Kochetkov, V.

    1984-08-29

    The authors discuss experience with treatment of nervous system disorders by means of laser-puncture therapy. Commenting on the background of the selection of this type of treatment, they explain that once researchers determined the biological action of laser light on specific nerve receptors of the skin, development of laser apparatus capable of concentrating the beam in the millimeter band was undertaken. The devices that are being used for laser-puncture are said to operate in the red helium-neon band of light. The authors identify beam parameters that have been selected for different groups of acupuncture points of the skin, and the courses of treatment (in seconds of radiation) and their time intervals. They go on to discuss the results of treatment of over 800 patients categorized in a group with disorders of the peripheral nervous system and a second group with disorders of the central nervous system.

  14. The Over-Barrier Resonant States and Multi-Channel Scattering in Multiple Quantum Wells

    Directory of Open Access Journals (Sweden)

    A Polupanov

    2016-09-01

    Full Text Available We demonstrate an explicit numerical method for accurate calculation of the scattering matrix and its poles, and apply this method to describe the multi-channel scattering in the multiple quantum-wells structures. The S-matrix is continued analytically to the unphysical region of complex energy values. Results of calculations show that there exist one or more S-matrix poles, corresponding to the over-barrier resonant states critical for the effect of the absolute reflection of holes in the energy range where only the heavy ones may propagate over barriers in a structure. Light- and heavy-hole states are described by the Luttinger Hamiltonian matrix. In contrast to the single quantum-well case, at some parameters of a multiple quantum-wells structure the number of S-matrix poles may exceed that of the absolute reflection peaks, and at different values of parameters the absolute reflection peak corresponds to different resonant states. The imaginary parts of the S-matrix poles and hence the lifetimes of resonant states as well as the widths of resonant peaks of absolute reflection depend drastically on the quantum-well potential depth. In the case of shallow quantum wells there is in fact a long-living over-barrier resonant hole state.

  15. Stochastic geometry model for multi-channel fog radio access networks

    KAUST Repository

    Emara, Mostafa

    2017-06-29

    Cache-enabled base station (BS) densification, denoted as a fog radio access network (F-RAN), is foreseen as a key component of 5G cellular networks. F-RAN enables storing popular files at the network edge (i.e., BS caches), which empowers local communication and alleviates traffic congestions at the core/backhaul network. The hitting probability, which is the probability of successfully transmitting popular files request from the network edge, is a fundamental key performance indicator (KPI) for F-RAN. This paper develops a scheduling aware mathematical framework, based on stochastic geometry, to characterize the hitting probability of F-RAN in a multi-channel environment. To this end, we assess and compare the performance of two caching distribution schemes, namely, uniform caching and Zipf caching. The numerical results show that the commonly used single channel environment leads to pessimistic assessment for the hitting probability of F-RAN. Furthermore, the numerical results manifest the superiority of the Zipf caching scheme and quantify the hitting probability gains in terms of the number of channels and cache size.

  16. Exploring Multi-Channel Shopping Behavior Towards It & C Products, Based on Business Students Opinions

    Directory of Open Access Journals (Sweden)

    Cristinel Vasiliu

    2016-02-01

    Full Text Available Young people have rapidly adopted the practice of using a variety of channels through which to shop, especially for products that require thorough information on features and price. IT & C products fall into this category, and buyers using multiple channels benefit from the advantages of information from online stores and reduced risks associated with the acquisition from traditional stores. The aim of this article is to identify young people preference for buying IT & C products from companies that distribute them across multiple channels. In this regard, an exploratory research was conducted on a sample of 340 students. The main results showed the high frequency use of Internet as a means of searching the information needed for purchasing IT & C products, the low share of exclusively online purchase, the fact that they are being perceived by students as both a need and a desire, and the weak expression of views about products purchased in the virtual environment. Price and quality are the main criteria in choosing them. Originality of this article is determined by identifying students’ preference for firms practicing multi-channel distribution strategy for IT & C products. Basically, people that we investigated gather online information about these products, from companies’ sites, but they mainly buy them in traditional stores.

  17. 4 × 160-Gbit/s multi-channel regeneration in a single fiber.

    Science.gov (United States)

    Wang, Ju; Ji, Hua; Hu, Hao; Yu, Jinlong; Mulvad, Hans Christian Hansen; Galili, Michael; Jeppesen, Palle; Oxenløwe, Leif Katsuo

    2014-05-19

    Simultaneous regeneration of four high-speed (160 Gbit/s) wavelength-division multiplexed (WDM) and polarization-division multiplexed (PDM) signals in a single highly nonlinear fiber (HNLF) is demonstrated. The regeneration operation is based on four-wave mixing in HNLF, where the degraded data signals are applied as the pump. As a result, the noise on both '0' and '1' levels can be suppressed simultaneously in our scheme. The stimulated Brillouin scattering (SBS) from the continuous wave (CW) is suppressed by cross-phase modulation (XPM) from the data pump, relieving the requirement of external phase modulation of the CW light. Mitigation of the inter-channel nonlinearities is achieved mainly through an inter-channel 0.5 bit slot time delay. Bidirectional propagation is also applied to relieve the inter-channel four-wave mixing. The multi-channel regeneration performance is validated by bit-error rate (BER) measurements. The receiver powers at the BER of 10(-9) are improved by 1.9 dB, 1.8 dB, 1.6 dB and 1.5 dB for the four data channels, respectively.

  18. Noninvasive imaging of internal muscle activities from multi-channel surface EMG recordings.

    Science.gov (United States)

    Zhang, Yingchun

    2013-01-01

    Surface Electromyogram (sEMG) technology provides a non-invasive way for rapid monitoring muscle activities, but its poor spatial resolution and specificity limit its application in clinic. To overcome these limitations, a noninvasive muscle activity imaging (MAI) approach has been developed and used to reconstruct internal muscle activities from multi-channel sEMG recordings. A realistic geometric hand model is developed from high-resolution MR images and a distributed bioelectric dipole source model is employed to describe the internal muscle activity space of the muscles. The finite element method and weighted minimum norm method are utilized solve the forward and inverse problems respectively involved in the proposed MAI technique. A series of computer simulations was conducted to test the performance of the proposed MAI approach. Results show that reconstruction results achieved by the MAI technique indeed provide us more detailed and dynamic information of internal muscle activities, which enhance our understanding of the mechanisms underlying the surface EMG recordings.

  19. Two-stage coordination multi-radio multi-channel mac protocol for wireless mesh networks

    CERN Document Server

    Zhao, Bingxuan

    2011-01-01

    Within the wireless mesh network, a bottleneck problem arises as the number of concurrent traffic flows (NCTF) increases over a single common control channel, as it is for most conventional networks. To alleviate this problem, this paper proposes a two-stage coordination multi-radio multi-channel MAC (TSC-M2MAC) protocol that designates all available channels as both control channels and data channels in a time division manner through a two-stage coordination. At the first stage, a load balancing breadth-first-search-based vertex coloring algorithm for multi-radio conflict graph is proposed to intelligently allocate multiple control channels. At the second stage, a REQ/ACK/RES mechanism is proposed to realize dynamical channel allocation for data transmission. At this stage, the Channel-and-Radio Utilization Structure (CRUS) maintained by each node is able to alleviate the hidden nodes problem; also, the proposed adaptive adjustment algorithm for the Channel Negotiation and Allocation (CNA) sub-interval is ab...

  20. Fabrication and validation of a multi-channel type microfluidic chip for electrokinetic streaming potential devices.

    Science.gov (United States)

    Chun, Myung-Suk; Shim, Min Suk; Choi, Nak Won

    2006-02-01

    To elaborate on the applicability of the electrokinetic micro power generation, we designed and fabricated the silicon-glass as well as the PDMS-glass microfluidic chips with the unique features of a multi-channel. Besides miniaturizing the device, the key advantage of our microfluidic chip utilization lies in the reduction in water flow rate. Both a distributor and a collector taking the tapered duct geometry are positioned aiming the uniform distribution of water flow into all individual channels of the chip, in which several hundreds of single microchannels are assembled in parallel. A proper methodology is developed accompanying the deep reactive ion etching as well as the anodic bonding, and optimum process conditions necessary for hard and soft micromachining are presented. It has been shown experimentally and theoretically that the silicon-based microchannel leads to increasing streaming potential and higher external current compared to those of the PDMS-based one. A proper comparison between experimental results and theoretical computations allows justification of the validity of our novel devices. It is useful to recognize that a material inducing a higher magnitude of zeta potential has an advantage for obtaining higher power density under the same external resistance.

  1. Dimensionality Reduction on Multi-Dimensional Transfer Functions for Multi-Channel Volume Data Sets

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P.; Cone, Angela C.; Sosinsky, Gina E.; Martone, Maryann E.

    2011-01-01

    The design of transfer functions for volume rendering is a non-trivial task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel, which requires multi-dimensional transfer functions. In this paper, we propose a new method for multi-dimensional transfer function design. Our new method provides a framework to combine multiple computational approaches and pushes the boundary of gradient-based multi-dimensional transfer functions to multiple channels, while keeping the dimensionality of transfer functions at a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. Applying recently developed nonlinear dimensionality reduction algorithms reduces the high-dimensional data of the domain. In this paper, we use Isomap and Locally Linear Embedding as well as a traditional algorithm, Principle Component Analysis. Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. We demonstrate the effectiveness of our new dimensionality reduction algorithms with two volumetric confocal microscopy data sets. PMID:21841914

  2. A flexible multi-channel high-resolution time-to-digital converter ASIC

    CERN Document Server

    Mota, M; Debieux, S; Ryzhov, V; Moreira, P; Marchioro, A

    2000-01-01

    A data driven multi-channel Time-to-Digital Converter (TDC) circuit with programmable resolution ( similar to 25ps - 8OOps binning) and a dynamic range of 102.4mus has been implemented in a 0.25mum CMOS technology. An on-chip PLL is used for clock multiplication up to 320MHz from an external 40MHz reference. A 32 element Delay Locked Loop (DLL) performs time interpolation down to 97.5ps. Finally, finer time interpolation is obtained using four samples of the DLL separated by 24.5ps generated by an adjustable on-chip RC delay line. In the lower resolution modes of operation, 32 TDC channels are available. In the highest resolution mode eight channels are available, since four low-resolution channels are used to perform a single fine time interpolation. The TDC is capable of measuring both leading and trailing edges of the input signal. Measurements are initially stored as time stamps in individual four-location deep asynchronous channel buffers. After proper encoding, measurements are written into four 256-dee...

  3. Development of a Multi-Channel Piezoelectric Acoustic Sensor Based on an Artificial Basilar Membrane

    Directory of Open Access Journals (Sweden)

    Youngdo Jung

    2013-12-01

    Full Text Available In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies. The length of the membrane is 28 mm and the width of the membrane varies from 1 mm to 8 mm. Multiphysics finite element analysis (FEA was carried out to predict and design the mechanical behaviors and piezoelectric response of the McPAS model. The designed McPAS was fabricated with a MEMS fabrication process based on the simulated results. The fabricated device was tested with a mouth simulator to measure its mechanical and piezoelectrical frequency response with a laser Doppler vibrometer and acoustic signal analyzer. The experimental results show that the as fabricated McPAS can successfully separate incoming acoustic signals within the 2.5 kHz–13.5 kHz range and the maximum electrical signal output upon acoustic signal input of 94 dBSPL was 6.33 mVpp. The performance of the fabricated McPAS coincided well with the designed parameters.

  4. Theoretical Valuation of Multi-Channel Cyclone to Reduce Gas Flow Dustiness in Agressive Environment

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2016-10-01

    Full Text Available Contaminated gas cleaning from finely divided solids is carried out using a new generation of multi-channel design cyclones. The application of these devices are separated and precipitated particles with a minimum diameter up to 2 micrometers, reaching up to 95% cleaning efficiency. Cyclones of such constructions are usually used under usual conditions at elevated temperature and low humidity. Under aggressive conditions, these devices can be clogged, and their recovery is not possible. Further studies are research into the application of constructive solutions to adapt the cyclone gas cleaning of the particulate matter under aggressive conditions. This theoretical evaluation has described the characteristics change of gas flow and particulate matters at different aggressive environment. Such conditions were loudly describe the gas-flow high-temperature range of 50–200 °C and gas-vapor stream, the humidity reaches 70–100%. Estimated aggressive conditions on the gas flow dynamics forces – pressure, resistance and centrifugal, and particulate mechanical – gravitational and adhesion strength. All parameters are evaluated in comparison with the values under normal conditions.

  5. Monitoring of ion implantation in microelectronics production environment using multi-channel reflectometry

    Science.gov (United States)

    Ebersbach, Peter; Urbanowicz, Adam M.; Likhachev, Dmitry; Hartig, Carsten

    2016-03-01

    Optical metrology techniques such as ellipsometry and reflectometry are very powerful for routine process monitoring and control in the modern semiconductor manufacturing industry. However, both methods rely on optical modeling therefore, the optical properties of all materials in the stack need to be characterized a priori or determined during characterization. Some processes such as ion implantation and subsequent annealing produce slight variations in material properties within wafer, wafer-to-wafer, and lot-to-lot; such variation can degrade the dimensional measurement accuracy for both unpatterned optical measurements as well as patterned (2D and 3D) scatterometry measurements. These variations can be accounted for if the optical model of the structure under investigation allows one to extract not just dimensional but also material information already residing within the optical spectra. This paper focuses on modeling of ion implanted and annealed poly Si stacks typically used in high-k technology. Monitoring of ion implantation is often a blind spot in mass production due to capability issues and other limitations of common methods. Typically, the ion implantation dose can be controlled by research-grade ellipsometers with extended infrared range. We demonstrate that multi-channel spectroscopic reflectometry can also be used for ion implant monitoring in the mass-production environment. Our findings are applicable across all technology nodes.

  6. 802.11s based multi-radio multi-channel mesh networking for fractionated spacecraft

    Science.gov (United States)

    Michel, Tony; Thapa, Bishal; Taylor, Steve

    802.11s is a new IEEE standard for mesh networking. It defines the protocols needed to build mobile ad hoc networks that operate over 802.11a, b, g and n waveforms running on inexpensive, and high performance commercial WiFi stations. We have developed a new capability to add to the 802.11s that uses multiple directional radio links that can operate simultaneously within a single mesh node. This is the basis of our multi-channel multi-radio mesh network used in the DARPA F6 program called F6Net. We have developed an analysis and emulation facility that lets us model the F6Net and evaluate the performance in a real world experimentation setup. This paper presents an “ Over-the-Air” experimentation testbed that uses standard Commercial Off-The-Shelf (COTS) 2.4GHz WiFi dongles in an indoor environment, and a shared-code simulation testbed that uses hardware simulated drivers within NS3's channel simulation facility to test 80211s network. To the best of our knowledge, this is the first work that provides a comprehensive evaluation platform with a full-fledged COTS hardware/software prototype to evaluate 802.11s network. Furthermore, we explain the design and development of multi-radio mesh extension for 802.11s that yields a robust and scalable mesh network suitable for clusters of LEO satellites.

  7. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    OpenAIRE

    Shin, Samuel M.; Duckworth, Tamara L.; Benjamin Thomas Cooper; Curtin, John P.; Schiff, Peter B.; J Keith DeWyngaert; Stella C Lymberis

    2015-01-01

    Introduction: Evaluate use of novel multi-channel applicator (MC) CapriTM to improve vaginal disease coverage achievable by single-channel applicator (SC) and comparable to Syed plan simulation. Material and Methods: 28 plans were evaluated from 4 patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by 3 weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth to 1500 cGy/3 fractions...

  8. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    OpenAIRE

    Shin, Samuel M.; Duckworth, Tamara L.; Cooper, Benjamin T; Curtin, John P.; Schiff, Peter B.; DeWyngaert, J. Keith; Stella C Lymberis

    2015-01-01

    Introduction Evaluate use of novel multi-channel applicator (MC) Capri™ to improve vaginal disease coverage achievable by single-channel applicator (SC) and comparable to Syed plan simulation. Materials and methods Twenty-eight plans were evaluated from four patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by three weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth...

  9. Experimental researches and comparison on aerodynamic parameters and cleaning efficiency of multi-level multi-channel cyclone

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2015-10-01

    Full Text Available Multi-level multi-channel cyclone – the lately designed air cleaning device that can remove ultra-fine 20 μm particulatematter (PM from dusted air and reach over 95% of the overall cleaning efficiency. Multi-channel cyclone technology is based on centrifugal forces and has the resulting additional filtering process operation. Multi-level structure of cyclone allows to achieve higher air flow cleaning capacity at the same dimensions of the device, thus saving installation space required for the job, production and operating costs. Studies have examined the air flow parameters change in one–, two– and three–levels multichannel cyclone. These constructions differ according to the productivity of cleaned air under the constant peripheral and transitional (50/50 case air flow relations. Accordance with the results of air flow dynamics – velocity distribution of multi-channel cyclone, aerodynamic resistance and efficiency can be judged on the flow turbulence, the flow channel cross-section and select the most appropriate application. Cleaning efficiency studies were carried out using fine granite and wood ashes PM. The maximum cleaning efficiency was 93.3%, at an average of 4.5 g/m3, the aerodynamic resistance was equal to 1525 Pa.

  10. MuLoG, or How to Apply Gaussian Denoisers to Multi-Channel SAR Speckle Reduction?

    Science.gov (United States)

    Deledalle, Charles-Alban; Denis, Loic; Tabti, Sonia; Tupin, Florence

    2017-09-01

    Speckle reduction is a longstanding topic in synthetic aperture radar (SAR) imaging. Since most current and planned SAR imaging satellites operate in polarimetric, interferometric or tomographic modes, SAR images are multi-channel and speckle reduction techniques must jointly process all channels to recover polarimetric and interferometric information. The distinctive nature of SAR signal (complex-valued, corrupted by multiplicative fluctuations) calls for the development of specialized methods for speckle reduction. Image denoising is a very active topic in image processing with a wide variety of approaches and many denoising algorithms available, almost always designed for additive Gaussian noise suppression. This paper proposes a general scheme, called MuLoG (MUlti-channel LOgarithm with Gaussian denoising), to include such Gaussian denoisers within a multi-channel SAR speckle reduction technique. A new family of speckle reduction algorithms can thus be obtained, benefiting from the ongoing progress in Gaussian denoising, and offering several speckle reduction results often displaying method-specific artifacts that can be dismissed by comparison between results.

  11. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI.

    Science.gov (United States)

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, Michal; Standara, Michal; Starčuk, Zenon; Taxt, Torfinn

    2016-03-01

    One of the main challenges in quantitative dynamic contrast-enhanced (DCE) MRI is estimation of the arterial input function (AIF). Usually, the signal from a single artery (ignoring contrast dispersion, partial volume effects and flow artifacts) or a population average of such signals (also ignoring variability between patients) is used. Multi-channel blind deconvolution is an alternative approach avoiding most of these problems. The AIF is estimated directly from the measured tracer concentration curves in several tissues. This contribution extends the published methods of multi-channel blind deconvolution by applying a more realistic model of the impulse residue function, the distributed capillary adiabatic tissue homogeneity model (DCATH). In addition, an alternative AIF model is used and several AIF-scaling methods are tested. The proposed method is evaluated on synthetic data with respect to the number of tissue regions and to the signal-to-noise ratio. Evaluation on clinical data (renal cell carcinoma patients before and after the beginning of the treatment) gave consistent results. An initial evaluation on clinical data indicates more reliable and less noise sensitive perfusion parameter estimates. Blind multi-channel deconvolution using the DCATH model might be a method of choice for AIF estimation in a clinical setup. © 2015 Wiley Periodicals, Inc.

  12. Slow scrambling in disordered quantum systems

    CERN Document Server

    Swingle, Brian

    2016-01-01

    Recent work has studied the growth of commutators as a probe of chaos and information scrambling in quantum many-body systems. In this work we study the effect of static disorder on the growth of commutators in a variety of contexts. We find generically that disorder slows the onset of scrambling, and, in the case of a many-body localized state, partially halts it. We access the many-body localized state using a standard fixed point Hamiltonian, and we show that operators exhibit slow logarithmic growth under time evolution. We compare the result with the expected growth of commutators in both localized and delocalized non-interacting disordered models. Finally, based on a scaling argument, we state a conjecture about the effect of weak interactions on the growth of commutators in an interacting diffusive metal.

  13. A Novel GBM Saliency Detection Model Using Multi-Channel MRI.

    Directory of Open Access Journals (Sweden)

    Subhashis Banerjee

    Full Text Available The automatic computerized detection of regions of interest (ROI is an important step in the process of medical image processing and analysis. The reasons are many, and include an increasing amount of available medical imaging data, existence of inter-observer and inter-scanner variability, and to improve the accuracy in automatic detection in order to assist doctors in diagnosing faster and on time. A novel algorithm, based on visual saliency, is developed here for the identification of tumor regions from MR images of the brain. The GBM saliency detection model is designed by taking cue from the concept of visual saliency in natural scenes. A visually salient region is typically rare in an image, and contains highly discriminating information, with attention getting immediately focused upon it. Although color is typically considered as the most important feature in a bottom-up saliency detection model, we circumvent this issue in the inherently gray scale MR framework. We develop a novel pseudo-coloring scheme, based on the three MRI sequences, viz. FLAIR, T2 and T1C (contrast enhanced with Gadolinium. A bottom-up strategy, based on a new pseudo-color distance and spatial distance between image patches, is defined for highlighting the salient regions in the image. This multi-channel representation of the image and saliency detection model help in automatically and quickly isolating the tumor region, for subsequent delineation, as is necessary in medical diagnosis. The effectiveness of the proposed model is evaluated on MRI of 80 subjects from the BRATS database in terms of the saliency map values. Using ground truth of the tumor regions for both high- and low- grade gliomas, the results are compared with four highly referred saliency detection models from literature. In all cases the AUC scores from the ROC analysis are found to be more than 0.999 ± 0.001 over different tumor grades, sizes and positions.

  14. A new algebraic method for quantitative proton density mapping using multi-channel coil data.

    Science.gov (United States)

    Cordes, Dietmar; Yang, Zhengshi; Zhuang, Xiaowei; Sreenivasan, Karthik; Mishra, Virendra; Hua, Le H

    2017-08-01

    A difficult problem in quantitative MRI is the accurate determination of the proton density, which is an important quantity in measuring brain tissue organization. Recent progress in estimating proton density in vivo has been based on using the inverse linear relationship between the longitudinal relaxation rate T1 and proton density. In this study, the same type of relationship is being used, however, in a more general framework by constructing 3D basis functions to model the receiver bias field. The novelty of this method is that the basis functions developed are suitable to cover an entire range of inverse linearities between T1 and proton density. The method is applied by parcellating the human brain into small cubes with size 30mm x 30mm x 30mm. In each cube the optimal set of basis functions is determined to model the receiver coil sensitivities using multi-channel (32 element) coil data. For validation, we use arbitrary data from a numerical phantom where the data satisfy the conventional MR signal equations. Using added noise of different magnitude and realizations, we show that the proton densities obtained have a bias close to zero and also low noise sensitivity. The obtained root-mean-square-error rate is less than 0.2% for the estimated proton density in a realistic 3D simulation. As an application, the method is used in a small cohort of MS patients, and proton density values for specific brain structures are determined. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Retrievals on Tropical small scale humidity variability from multi-channel microwave radiometer

    Science.gov (United States)

    Zhang, Jianhao; Zuidema, Paquita; Turner, David

    2016-04-01

    Small-scale atmospheric humidity structure is important to many atmospheric process studies. In the Tropics especially, convection is sensitive to small variations in humidity. High temporal-resolution humidity profiles and spatially-resolved humidity fields are valuable for understanding the relationship of convection to tropical humidity, such as at convectively-induced cold pools and as part of the shallow-to-deep cloud transition. Radiosondes can provide high resolution vertical profiles of temperature and humidity, but are relatively infrequent. Microwave radiometers (MWR) are able to profile and scan autonomously and output measurements frequently (~1 Hz). To date, few assessments of microwave humidity profiling in the Tropics have been undertaken. Löhnert et al. (2009) provide one evaluation for Darwin, Australia. We build on this using four months of data from the equatorial Indian Ocean, at Gan Island, collected from University of Miami's (UM) multi-channel radiometer during the Dynamics of Madden-Julian Oscillation (DYNAMO) field campaign. Liquid Water Path (LWP) and Water Vapor Path (WVP) are physically retrieved using the MWR RETrieval (MWRRET) algorithm (Turner et al., 2007b), and humidity profiles in the tropics are retrieved using the Integrated Profiling Technique (Löhnert et al., 2004). Tropical temperature variability is weak and a climatological temperature profile is assumed, with humidity information drawn from five channels between 22 to 30 GHz. Scanning measurements were coordinated with the scanning pattern of NCAR's S-Pol-Ka radar. An analysis of the humidity information content gathered from both the profiling and scanning measurements will be presented.

  16. Time-varying bispectral analysis of visually evoked multi-channel EEG

    Science.gov (United States)

    Chandran, Vinod

    2012-12-01

    Theoretical foundations of higher order spectral analysis are revisited to examine the use of time-varying bicoherence on non-stationary signals using a classical short-time Fourier approach. A methodology is developed to apply this to evoked EEG responses where a stimulus-locked time reference is available. Short-time windowed ensembles of the response at the same offset from the reference are considered as ergodic cyclostationary processes within a non-stationary random process. Bicoherence can be estimated reliably with known levels at which it is significantly different from zero and can be tracked as a function of offset from the stimulus. When this methodology is applied to multi-channel EEG, it is possible to obtain information about phase synchronization at different regions of the brain as the neural response develops. The methodology is applied to analyze evoked EEG response to flash visual stimulii to the left and right eye separately. The EEG electrode array is segmented based on bicoherence evolution with time using the mean absolute difference as a measure of dissimilarity. Segment maps confirm the importance of the occipital region in visual processing and demonstrate a link between the frontal and occipital regions during the response. Maps are constructed using bicoherence at bifrequencies that include the alpha band frequency of 8Hz as well as 4 and 20Hz. Differences are observed between responses from the left eye and the right eye, and also between subjects. The methodology shows potential as a neurological functional imaging technique that can be further developed for diagnosis and monitoring using scalp EEG which is less invasive and less expensive than magnetic resonance imaging.

  17. Extensions to the Speech Disorders Classification System (SDCS)

    Science.gov (United States)

    Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.

    2010-01-01

    This report describes three extensions to a classification system for paediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three sub-types of motor speech disorders.…

  18. Extensions to the Speech Disorders Classification System (SDCS)

    Science.gov (United States)

    Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.

    2010-01-01

    This report describes three extensions to a classification system for paediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three sub-types of motor speech disorders.…

  19. Effects on Humans Elicited by Inhaling the Fragrance of Essential Oils: Sensory Test, Multi-Channel Thermometric Study and Forehead Surface Potential Wave Measurement on Basil and Peppermint

    National Research Council Canada - National Science Library

    SATOH, Tomoko; SUGAWARA, Yoshiaki

    2003-01-01

    The effects on humans inhaling the fragrance of essential oils were examined in terms of a sensory test, a multi-channel skin thermometer study and a portable forehead surface electroencephalographic (IBVA-EEG) measurement...

  20. The research of the photocatalytic reaction system with multi-channel array under the synergistic effect of H2 O2%H2 O2协同作用下的多通道光催化反应体系研究

    Institute of Scientific and Technical Information of China (English)

    王常顺; 佘江波; 张国防

    2014-01-01

    使用具有547个孔道的微结构聚合物预制棒,建立了一种新型的光催化降解有机废水体系。通过微波热处理技术,TiO2纳米晶薄膜附着在光催化反应体系的孔道中。使得反应体系增加光催化剂和溶液的接触面积,提高了光催化效率,同时加入强氧化剂 H2 O2来协同TiO2用于光催化分解有机染料罗丹明B;研究了 H2 O2的浓度及RB的初始浓度对光催化的影响,表明该反应体系在光照的条件下具有降解有机染料的能力。%A new type of photocatalytic degradation of organic wastewater system based on microstructured polymer optical fiber (MPOF ) preform with 547 pores was designed, constructed,and each channel was covered with TiO2 film. The photocatalytic active TiO2 nanocrystal film that covered on the channels of the MPOF preform was obtained by microwave processing.Thus the inner surfaces of pores,used as the reactors for the photocatalyst,was expected to increase the photocatalyst-liquid contact area, and enhance the photocatalytic efficiency.Moreover,hydrogen peroxide was added as strong oxidant to synergy degradating Rhodamine B in solution.The effects of different initial hydrogen peroxide concentration and the dye concentration were investigated.The results indicated that the photocatalysis activity of the system was proved to possess the ability of degradating organic dye in the light.

  1. A Personalized Multi-Channel FES Controller Based on Muscle Synergies to Support Gait Rehabilitation after Stroke

    Science.gov (United States)

    Ferrante, Simona; Chia Bejarano, Noelia; Ambrosini, Emilia; Nardone, Antonio; Turcato, Anna M.; Monticone, Marco; Ferrigno, Giancarlo; Pedrocchi, Alessandra

    2016-01-01

    It has been largely suggested in neuroscience literature that to generate a vast variety of movements, the Central Nervous System (CNS) recruits a reduced set of coordinated patterns of muscle activities, defined as muscle synergies. Recent neurophysiological studies have recommended the analysis of muscle synergies to finely assess the patient's impairment, to design personalized interventions based on the specific nature of the impairment, and to evaluate the treatment outcomes. In this scope, the aim of this study was to design a personalized multi-channel functional electrical stimulation (FES) controller for gait training, integrating three novel aspects: (1) the FES strategy was based on healthy muscle synergies in order to mimic the neural solutions adopted by the CNS to generate locomotion; (2) the FES strategy was personalized according to an initial locomotion assessment of the patient and was designed to specifically activate the impaired biomechanical functions; (3) the FES strategy was mapped accurately on the altered gait kinematics providing a maximal synchronization between patient's volitional gait and stimulation patterns. The novel intervention was tested on two chronic stroke patients. They underwent a 4-week intervention consisting of 30-min sessions of FES-supported treadmill walking three times per week. The two patients were characterized by a mild gait disability (walking speed > 0.8 m/s) at baseline. However, before treatment both patients presented only three independent muscle synergies during locomotion, resembling two different gait abnormalities. After treatment, the number of extracted synergies became four and they increased their resemblance with the physiological muscle synergies, which indicated a general improvement in muscle coordination. The originally merged synergies seemed to regain their distinct role in locomotion control. The treatment benefits were more evident for one patient, who achieved a clinically important change

  2. The hydrogen diffusion in disordered systems

    Energy Technology Data Exchange (ETDEWEB)

    Kondratyev, V.V.; Gapontsev, A.V. [Institute of Metal Physics, Ural Branch of Russian Academy of Sciences, Ekaterinburg (Russian Federation); Voloshinskii, A.N.; Obukhov, A.G. [Ural Academy of Mining and Geology, Ekaterinburg (Russian Federation); Timofeyev, N.I. [Ekaterinburg Works for Nonferrous Metals (Russian Federation)

    1999-09-01

    This paper analyzes the experimental data and presents a critical review of the existing approaches to the description of hydrogen diffusion in disordered amorphous alloys. It is noted that the available theories ignore the role of the short-range order in hydrogen diffusion. A diffusion model, which is based on the approach developed by us earlier, has been proposed for disordered crystalline alloys. In terms of this model specific features of the amorphous state are allowed for by homogeneous local distortions of voids, i.e. a kind of 'frozen' fluctuations of the free volume. General expressions for the chemical diffusion coefficient of hydrogen in amorphous metals and binary alloys having FCC-like short-range crystalline order have been derived. It was shown that the diffusion coefficient may depend on a structural characteristic of disordered systems the mean square of static displacement of atoms in the vicinity of a void and also on the paired radial distribution function of atoms. The analysis of the proposed model suggests that the crystalline disorder causes an increase in the diffusion coefficient, which grows (unlike in crystals) linearly with the hydrogen concentration.

  3. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Guangkai [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China and Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Wu, Guorong [Department of Computer Science, Department of Radiology, and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Wu, Ligang [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001 (China); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2016-02-15

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  4. Generic Feasibility of Perfect Reconstruction with Short FIR Filters in Multi-channel Systems

    CERN Document Server

    Sharif, Behzad

    2011-01-01

    We study the feasibility of short finite impulse response (FIR) synthesis for perfect reconstruction (PR) in generic FIR filter banks. Among all PR synthesis banks, we focus on the one with the minimum filter length. For filter banks with oversampling factors of at least two, we provide prescriptions for the shortest filter length of the synthesis bank that would guarantee PR almost surely. The prescribed length is as short or shorter than the analysis filters and has an approximate inverse relationship with the oversampling factor. Our results are in form of necessary and sufficient statements that hold generically, hence only fail for elaborately-designed nongeneric examples. We provide extensive numerical verification of the theoretical results and demonstrate that the gap between the derived filter length prescriptions and the true minimum is small. The results have potential applications in synthesis FB design problems, where the analysis bank is given, and for analysis of fundamental limitations in blin...

  5. High speed, multi-channel, user programmable digital data acquisition system.

    Energy Technology Data Exchange (ETDEWEB)

    Sabourov, Konstantin [XIA LLC; Hennig, Wolfgang [XIA LLC; Walby, Mark [XIA LLC

    2013-11-18

    As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

  6. 3D Multi-Channel Networked Visualization System for National LambdaRail Project

    Data.gov (United States)

    National Aeronautics and Space Administration — National LambdaRail (NLR) offers unprecedented communication capabilities on the National and possibly International levels. Physical Optics Corporation (POC)...

  7. 3D Multi-Channel Networked Visualization System for National LambdaRail Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Multichannel virtual reality visualization is the future of complex simulation with a large number of visual channels rendered and transmitted over high-speed...

  8. On the Relaxation Dynamics of Disordered Systems

    Science.gov (United States)

    Dobramysl, Ulrich

    We investigate the properties of two distinct disordered systems: the two-species predator-prey Lotka-Volterra model with rate variability, and an elastic line model to simulate vortex lines in type-II superconductors. We study the effects of intrinsic demographic variability with inheritance in the reaction rates of the Lotka-Volterra model via zero-dimensional Monte Carlo simulations as well as two-dimensional lattice simulations. Individuals of each species are assigned inheritable predation efficiencies during their creation, leading to evolutionary dynamics and thus population-level optimization. We derive an effective subspecies mean-field theory and compare its results to our numerical data. Furthermore, we introduce environmental variability via quenched spatial reaction-rate randomness. We investigate the competing effects and relative importance of the two types of variability, and find that both lead to a remarkable enhancement of the species densities, while the aforementioned optimization effects are essentially neutral in the densities. Additionally, we collected extinction time histograms for small systems and find a marked increase in the stability of the populations against extinction due to the presence of variability. We employ an elastic line model to investigate the steady-state properties and non-equilibrium relaxation kinetics of magnetic vortex lines in disordered type-II superconductors. To this end, we developed a versatile and efficient Langevin molecular dynamics simulation code, allowing us to do a careful study of samples with or without vortex-vortex interactions or disorder allows us to disentangle the various complex relaxational features present in this system and investigate their origin. In particular, we compare disordered samples with randomly distributed point defects versus correlated columnar defects. We extract two-time quantities such as the mean-square displacement, the height and density correlations, to investigate the

  9. Systemic Light Chain Amyloidosis Mimicking Rheumatic Disorders

    Science.gov (United States)

    2016-01-01

    Secondary amyloidosis can complicate chronic inflammatory autoimmune diseases. However, the clinical findings of primary amyloidosis may mimic those of primary rheumatologic disorders. We present the case of a 53-year-old woman who presented with dystrophic nail changes, dry eyes, bilateral carpal tunnel syndrome, Raynaud's phenomenon, and high titer positive nucleolar pattern antinuclear antibody. She was initially misdiagnosed as having Undifferentiated Connective Tissue Disease (UCTD). On further workup, she was eventually diagnosed with lambda light chain systemic amyloidosis by abdominal fat pad biopsy. Her symptoms completely resolved after autologous stem cell transplantation. With this case, we would like to highlight the similarities in the clinical features between light chain amyloidosis and rheumatological disorders. We would also like to emphasize the importance of the prompt recognition of the clinical features of amyloidosis which are crucial to triggering appropriate diagnostic procedures, since early diagnosis is a key to improving outcomes in this disease with an otherwise poor prognosis. PMID:28042297

  10. Systemic Light Chain Amyloidosis Mimicking Rheumatic Disorders

    Directory of Open Access Journals (Sweden)

    Rohit R. Rao

    2016-01-01

    Full Text Available Secondary amyloidosis can complicate chronic inflammatory autoimmune diseases. However, the clinical findings of primary amyloidosis may mimic those of primary rheumatologic disorders. We present the case of a 53-year-old woman who presented with dystrophic nail changes, dry eyes, bilateral carpal tunnel syndrome, Raynaud’s phenomenon, and high titer positive nucleolar pattern antinuclear antibody. She was initially misdiagnosed as having Undifferentiated Connective Tissue Disease (UCTD. On further workup, she was eventually diagnosed with lambda light chain systemic amyloidosis by abdominal fat pad biopsy. Her symptoms completely resolved after autologous stem cell transplantation. With this case, we would like to highlight the similarities in the clinical features between light chain amyloidosis and rheumatological disorders. We would also like to emphasize the importance of the prompt recognition of the clinical features of amyloidosis which are crucial to triggering appropriate diagnostic procedures, since early diagnosis is a key to improving outcomes in this disease with an otherwise poor prognosis.

  11. Multi-channel EEG-based sleep stage classification with joint collaborative representation and multiple kernel learning.

    Science.gov (United States)

    Shi, Jun; Liu, Xiao; Li, Yan; Zhang, Qi; Li, Yingjie; Ying, Shihui

    2015-10-30

    Electroencephalography (EEG) based sleep staging is commonly used in clinical routine. Feature extraction and representation plays a crucial role in EEG-based automatic classification of sleep stages. Sparse representation (SR) is a state-of-the-art unsupervised feature learning method suitable for EEG feature representation. Collaborative representation (CR) is an effective data coding method used as a classifier. Here we use CR as a data representation method to learn features from the EEG signal. A joint collaboration model is established to develop a multi-view learning algorithm, and generate joint CR (JCR) codes to fuse and represent multi-channel EEG signals. A two-stage multi-view learning-based sleep staging framework is then constructed, in which JCR and joint sparse representation (JSR) algorithms first fuse and learning the feature representation from multi-channel EEG signals, respectively. Multi-view JCR and JSR features are then integrated and sleep stages recognized by a multiple kernel extreme learning machine (MK-ELM) algorithm with grid search. The proposed two-stage multi-view learning algorithm achieves superior performance for sleep staging. With a K-means clustering based dictionary, the mean classification accuracy, sensitivity and specificity are 81.10 ± 0.15%, 71.42 ± 0.66% and 94.57 ± 0.07%, respectively; while with the dictionary learned using the submodular optimization method, they are 80.29 ± 0.22%, 71.26 ± 0.78% and 94.38 ± 0.10%, respectively. The two-stage multi-view learning based sleep staging framework outperforms all other classification methods compared in this work, while JCR is superior to JSR. The proposed multi-view learning framework has the potential for sleep staging based on multi-channel or multi-modality polysomnography signals. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Accurate and representative decoding of the neural drive to muscles in humans with multi-channel intramuscular thin-film electrodes.

    Science.gov (United States)

    Muceli, Silvia; Poppendieck, Wigand; Negro, Francesco; Yoshida, Ken; Hoffmann, Klaus P; Butler, Jane E; Gandevia, Simon C; Farina, Dario

    2015-09-01

    Intramuscular electrodes developed over the past 80 years can record the concurrent activity of only a few motor units active during a muscle contraction. We designed, produced and tested a novel multi-channel intramuscular wire electrode that allows in vivo concurrent recordings of a substantially greater number of motor units than with conventional methods. The electrode has been extensively tested in deep and superficial human muscles. The performed tests indicate the applicability of the proposed technology in a variety of conditions. The electrode represents an important novel technology that opens new avenues in the study of the neural control of muscles in humans. We describe the design, fabrication and testing of a novel multi-channel thin-film electrode for detection of the output of motoneurones in vivo and in humans, through muscle signals. The structure includes a linear array of 16 detection sites that can sample intramuscular electromyographic activity from the entire muscle cross-section. The structure was tested in two superficial muscles (the abductor digiti minimi (ADM) and the tibialis anterior (TA)) and a deep muscle (the genioglossus (GG)) during contractions at various forces. Moreover, surface electromyogram (EMG) signals were concurrently detected from the TA muscle with a grid of 64 electrodes. Surface and intramuscular signals were decomposed into the constituent motor unit (MU) action potential trains. With the intramuscular electrode, up to 31 MUs were identified from the ADM muscle during an isometric contraction at 15% of the maximal force (MVC) and 50 MUs were identified for a 30% MVC contraction of TA. The new electrode detects different sources from a surface EMG system, as only one MU spike train was found to be common in the decomposition of the intramuscular and surface signals acquired from the TA. The system also allowed access to the GG muscle, which cannot be analysed with surface EMG, with successful identification of MU

  13. A multi-channel 24.4 ps bin size Time-to-Digital Converter for HEP applications

    CERN Document Server

    Mester, C; Morira, P

    2008-01-01

    A multi-channel time-tagging Time-to-Digital Converter (TDC) ASIC with a resolution of 24.4 ps (bin size) has been implemented and fabricated in a 130 nm CMOS technology. An on-chip PLL is used to generate an internal timing reference from an external 40 MHz clock source. The circuit is based on a 32 element Delay Locked Loop (DLL) which performs the time interpolation. The 32 channel architecture of the TDC is suitable for both triggered and non-triggered applications. The prototype contains test structures such as a substrate noise generator. The paper describes the circuit architecture and its principles of operation.

  14. Fiber-distributed multi-channel open-path H2S sensor based on tunable diode laser absorption spectroscopy

    Institute of Scientific and Technical Information of China (English)

    Dong Chen; Wenqing Liu; Yujun Zhang; Jianguo Liu; Ruifeng Kan; Min Wang; Xi Fang; Yiben Cui

    2007-01-01

    Tunable diode laser based gas detectors are now being used in a wide variety of applications for safety and environmental interest. A fiber-distributed multi-channel open-path H2S sensor based on tunable diode laser absorption spectroscopy (TDLAS) is developed, the laser used is a telecommunication near infrared distributed feed-back (DFB) tunable diode laser, combining with wavelength modulation specby combining optical fiber technique. An on-board reference cell provides on-line sensor calibration and almost maintenance-free operation. The sensor is suitable for large area field H2S monitoring application.

  15. Multi-channel Wiener Filter for Speech Dereverberation in Hearing Aids - Sensitivity to DoA Errors

    DEFF Research Database (Denmark)

    Kuklasinski, Adam; Doclo, Simon; Jensen, Søren Holdt

    2016-01-01

    In this paper we study the robustness of a recently proposed Multi-channel Wiener Filter-based speech dereverberation algorithm to errors in the assumed direction of arrival (DoA) of the target speech. Different subsets of microphones of a pair of behind-the-ear hearing aids are used to construct...... various monaural and binaural configurations of the algorithm. Via a simulation experiment with frontally positioned target it is shown, that when correct DoA is assumed binaural configurations of the algorithm almost double the improvement of PESQ measure over monaural configurations. However...

  16. Psychiatric disorders in Systemic Lupus Erythematosus.

    Science.gov (United States)

    Hutchinson, G A; Nehall, J E; Simeon, D T

    1996-06-01

    The symptoms of Systemic Lupus Erythematosus (SLE) may include altered mental function. The present study sought to determine whether the psychiatric disorders are due to the disease itself or to the stress of having a chronic disease. Forty-five SLE patients attending outpatient clinics at the Port-of-Spain General Hospital in Trinidad were compared with two control groups: patients with chronic debilitating diseases similar to SLE in terms of chronicity and treatment (n = 44) and non-diseased individuals (n = 48). The Structured Clinical Interview for DSM III-R was used to identify psychiatric disorders. Both the SLE and the chronic illness groups had more psychiatric illness (44% and 39%, respectively) when compared with the non-diseased controls (2%) (p < 0.001). Major depression was the most common diagnosis among both diseased groups. However, psychotic illnesses (schizophrenic-type psychosis and bipolar disorders) were more prevalent in the SLE group (11.1% vs 0%, p = 0.02). These results indicate that major depression in SLE may be related more to the effects of a chronic illness than to SLE itself. However, the occurrence of psychotic symptoms may be related to SLE disease and needs further study.

  17. Periodontal disease associated to systemic genetic disorders.

    Science.gov (United States)

    Nualart Grollmus, Zacy Carola; Morales Chávez, Mariana Carolina; Silvestre Donat, Francisco Javier

    2007-05-01

    A number of systemic disorders increase patient susceptibility to periodontal disease, which moreover evolves more rapidly and more aggressively. The underlying factors are mainly related to alterations in immune, endocrine and connective tissue status. These alterations are associated with different pathologies and syndromes that generate periodontal disease either as a primary manifestation or by aggravating a pre-existing condition attributable to local factors. This is where the role of bacterial plaque is subject to debate. In the presence of qualitative or quantitative cellular immune alterations, periodontal disease may manifest early on a severe localized or generalized basis--in some cases related to the presence of plaque and/or specific bacteria (severe congenital neutropenia or infantile genetic agranulocytosis, Chediak-Higiashi syndrome, Down syndrome and Papillon-Lefévre syndrome). In the presence of humoral immune alterations, periodontal damage may result indirectly as a consequence of alterations in other systems. In connective tissue disorders, bacterial plaque and alterations of the periodontal tissues increase patient susceptibility to gingival inflammation and alveolar resorption (Marfan syndrome and Ehler-Danlos syndrome). The management of periodontal disease focuses on the control of infection and bacterial plaque by means of mechanical and chemical methods. Periodontal surgery and even extraction of the most seriously affected teeth have also been suggested. There are variable degrees of consensus regarding the background systemic disorder, as in the case of Chediak-Higiashi syndrome, where antibiotic treatment proves ineffective; in severe congenital neutropenia or infantile genetic agranulocytosis, where antibiotic prophylaxis is suggested; and in Papillon-Lefévre syndrome, where an established treatment protocol is available.

  18. First Results from the Multi-beam Bathymetry and Multi-channel Seismic Reflection Data offshore Cide-Sinop, Southern Black Sea shelf

    Science.gov (United States)

    Alp, Y. I.; Ocakoglu, N.; Kılıc, F.; Ozel, A. O.

    2016-12-01

    The morphological and seismic features offshore Cide-Sinop at the Southern Black Sea shelf area were first time investigated by multi-beam bathymetric and multi-channel seismic reflection data under the Research Project of The Scientific and Technological Research Council of Turkey (TUBİTAK-ÇAYDAG-114Y057). Multi-beam bathymetric data were collected between 2002-2008 from onboard the research vessels TCG Çubuklu and TCG Çeşme run by the Turkish Navy, Department of Navigation, Hydrography and Oceanography (TN-DNHO) with the system an Elac-Nautic 1050D. Multi-channel seismic reflection data were collected by Turkish Petroleum Corporation (TPAO) Company in 1991. Multi-beam measurements cover 2.59 km2 areas and depths change from -1 to -500 m. Elevation data were digitized from contour lines of 1/25K topo-maps of General Command of Mapping, with the contour interval of 10 m and supplementary 5 m contours in areas of low relief. Contour and shore lines, multi-beam points were interpolated into DEMs of pixel size 10 m and 5 m respectively, using Annudem algorithm. The Geographic Information System (GIS) software was used to analyse and visualize the two data sets. Seismic reflection data were processed by conventional methods under `Echos' seismic data processing software and time migrated seismic sections were produced. DEMs were combined with seismic reflection sections to understand the morphological and morphodynamic character of the study area. First results indicate that offshore Cide-Sinop is characterised by a quite smooth and large shelf plain with an approx. 25 km wide and the water depth of about -100 m. The bathymetry gently deepens from inner shelf toward shelf break at -120 m isobath. Slope angles from 0 to 1 degrees at the shelf plain, increases about to 10 degrees beyond the shelf edge. The large shelf plain is widely characterized by sand dunes with an average height of 10 meters form E-W oriented belts of 500-1000 m in width. Toward offshore

  19. Design Study of a Multi-channel Array Particle Spectrometer for Space Missions

    Science.gov (United States)

    Trindade, Andreia; Assis, P.; Brogueira, P.; Gonçalves, P.; Keating, A.; Pimenta, M.; Rodrigues, P.; Trindade, A.

    In this work, a novel particle spectrometer is proposed to fulfil the need to map the space radiation environment for future space missions and to provide more accurate scientific data. The concept of the instrument brings together new radiation-hard technologies, for the photo-sensors and scintillating materials that will improve the quality of the data, while taking into account the limited resources such as mass, power and accommodation, allocated for space radiation monitors. The Multi-channel Array Particle Spectrometer (MAPS), can measure fluxes and energy dis-tributions of protons, ions, electrons and gammas in a wide energy range based on the 3D reconstruction of the particle track through the detector and its deposited energy in the active volume. It consists on a 8 x 8 segmented scintillator block built from 3.2 x 3.2 x 20 mm3 indi-vidual LYSO:Ce rods that are readout at both ends by two 64 pixel Silicon Photo-Multipliers (SiPMs) matrices, a new generation of high gain (105-106) avalanche photodiodes working in controlled Geiger mode, that collect the scintillating light produced by the interactions of the charged particles in the crystals. Each SiPM matrix is readout by a 64 channel mixed sig-nal analog-digital ASIC, offering both particle identification and particle counting capabilities. Power cycling design of the ASIC allows to activate the particle identification block only during a pre-determined time slice, keeping the total power budget of less than 1 mW/channel. An on-board FPGA sorts the serialized data from the two ASICs and computes the trigger primitives in real-time and in an event-by-event basis. Whenever a charged particle crosses the segmented volume of the detector, the XY coordinates, given by the pixelized crystal positions, and the deposited energy in each crystal is recorded. The double readout scheme allows to compute the light collection asymmetry between both ends of the crystal and to use that information to record the

  20. Nasal surgery in patients with systemic disorders

    Directory of Open Access Journals (Sweden)

    Sachse, Florian

    2010-01-01

    Full Text Available Multisystemic disorders represent a heterogenous group of diseases which can primarily manifest at the nose and paranasal sinuses as limited disease or secondarily as part of systemic involvement. Rhinologists therefore play an important role in the diagnostic but also therapeutic process. Although therapy of multisystemic disorders is primary systemic, additional rhinosurgery may become necessary. The spectrum of procedures consists of sinus surgery, surgery of the orbit and lacrimal duct, septorhinoplasty and closure of nasal septal perforation. Since the prevalence of most systemic diseases is very rare, recommendations are based on the analysis of single case reports and case series with a limited number of patients only. Although data is still limited, experiences published so far have shown that autologous cartilage or bone grafts can be used in nasal reconstruction of deformities caused by tuberculosis, leprosy, Wegener’s granulomatosis, sarcoidosis and relapsing polychondritis. Experiences gained from these diseases support the concept that well-established techniques of septorhinoplasty can be used in systemic diseases as well. However, a state of remission is an essential condition before considering any rhinosurgery in these patients. Even under these circumstances revision surgery has to be expected more frequently compared to the typical collective of patients undergoing septorhinoplasty. In addition, experiences gained from saddle nose reconstruction may in part be of value for the treatment of nasal septal perforations since implantation of cartilage grafts often represents an essential step in multilayer techniques of closure of nasal septal perforations. Aside from the treatment of orbital complications sinus surgery has been proven beneficial in reducing nasal symptoms and increasing quality of life in patients refractory to systemic treatment.

  1. Electrical properties of flexible multi-channel Si nanowire field-effect transistors depending on the number of Si nanowires.

    Science.gov (United States)

    Kim, Do Hoon; Lee, Su Jeong; Lee, Sang Hoon; Myoung, Jae-Min

    2016-05-25

    Flexible multi-channel Si nanowire (NW) field-effect transistors (FETs) were investigated to determine the effect of the number of Si NWs. The Langmuir-Blodgett method was applied for the formation of well-aligned Si NW monolayers, and an ion-gel with a high dielectric constant was used as a gate insulator in a top-gate TFT structure to secure flexibility. Like typical nanoelectronic devices, the drain current changed with the number of Si NWs. However, unlike previous reports, the mobility of the multi-channel Si NW FETs increased from 42.8 to 124.6 cm(2) V(-1) s(-1) as the number of Si NWs was increased from 1 to 58. To verify the feasibility of our approach, the electrical performance of the TFTs fabricated on a flexible polyimide (PI) substrate was analyzed in respect of the bending strain (0.08-1.51%) and bending cycle (up to 12 000 cycles). As the number of Si NWs was increased, the trade-off between electrical and mechanical properties during bending tests was confirmed, and the appropriate number of Si NWs was optimized for a flexible FET with excellent performance.

  2. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    Science.gov (United States)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both pfunction.

  3. Disordered complex systems using cold gases and trapped ions

    CERN Document Server

    De, A S; Lewenstein, M; Ahufinger, V; Pons, M L; Sanpera, A; De, Aditi Sen; Sen, Ujjwal; Lewenstein, Maciej; Ahufinger, Veronica; Pons, Marisa Ll.; Sanpera, Anna

    2005-01-01

    We report our research on disordered complex systems using cold gases and trapped ions, and address the possibility of using complex systems for quantum information processing. Two simple paradigmatic models of disordered complex systems are revisited here. The first one corresponds to a short range disordered Ising Hamiltonian (spin glasses), which can be implemented with a Bose-Fermi (Bose-Bose) mixture in a disordered optical lattice. The second model we address here is a long range disordered Hamiltonian, characteristic of neural networks (Hopfield model), which can be implemented in a chain of trapped ions with appropriately designed interactions.

  4. Uric Acid Nephrolithiasis: A Systemic Metabolic Disorder

    Science.gov (United States)

    Moe, Orson W.

    2014-01-01

    Uric acid nephrolithiasis is characteristically a manifestation of a systemic metabolic disorder. It has a prevalence of about 10% among all stone formers, the third most common type of kidney stone in the industrialized world. Uric acid stones form primarily due to an unduly acid urine; less deciding factors are hyperuricosuria and a low urine volume. The vast majority of uric acid stone formers have the metabolic syndrome, and not infrequently, clinical gout is present as well. A universal finding is a low baseline urine pH plus insufficient production of urinary ammonium buffer. Persons with gastrointestinal disorders, in particular chronic diarrhea or ostomies, and patients with malignancies with a large tumor mass and high cell turnover comprise a less common but nevertheless important subset. Pure uric acid stones are radiolucent but well visualized on renal ultrasound. A 24 h urine collection for stone risk analysis provides essential insight into the pathophysiology of stone formation and may guide therapy. Management includes a liberal fluid intake and dietary modification. Potassium citrate to alkalinize the urine to a goal pH between 6 and 6.5 is essential, as undissociated uric acid deprotonates into its much more soluble urate form. PMID:25045326

  5. Fluorescence-based Sensing of 2,4,6-Trinitrotoluene (TNT Using a Multi-channeled Poly(methyl methacrylate (PMMA Microimmunosensor

    Directory of Open Access Journals (Sweden)

    Anne W. Kusterbeck

    2010-01-01

    Full Text Available Fluorescence immunoassays employing monoclonal antibodies directed against the explosive 2,4,6-trinitrotoluene (TNT were conducted in a multi-channel microimmunosensor. The multi-channel microimmunosensor was prepared in poly (methyl methacrylate (PMMA via hot embossing from a brass molding tool. The multi-channeled microfluidic device was sol-gel coated to generate a siloxane surface that provided a scaffold for antibody immobilization. AlexaFluor-cadaverine-trinitrobenzene (AlexaFluor-Cad-TNB was used as the reporter molecule in a displacement immunoassay. The limit of detection was 1-10 ng/mL (ppb with a linear dynamic range that covered three orders of magnitude. In addition, antibody crossreactivity was investigated using hexahydro-1,3,5-triazine (RDX, HMX, 2,4-dinitrotoluene (DNT, 4-nitrotoluene (4-NT and 2-amino-4,6-DNT.

  6. Effective Dynamics of Disordered Quantum Systems

    Science.gov (United States)

    Kropf, Chahan M.; Gneiting, Clemens; Buchleitner, Andreas

    2016-07-01

    We derive general evolution equations describing the ensemble-average quantum dynamics generated by disordered Hamiltonians. The disorder average affects the coherence of the evolution and can be accounted for by suitably tailored effective coupling agents and associated rates that encode the specific statistical properties of the Hamiltonian's eigenvectors and eigenvalues, respectively. Spectral disorder and isotropically disordered eigenvector distributions are considered as paradigmatic test cases.

  7. The EarthScope Array Network Facility: application-driven low-latency web-based tools for accessing high-resolution multi-channel waveform data

    Science.gov (United States)

    Newman, R. L.; Lindquist, K. G.; Clemesha, A.; Vernon, F. L.

    2008-12-01

    Since April 2004 the EarthScope USArray seismic network has grown to over 400 broadband stations that stream multi-channel data in near real-time to the Array Network Facility in San Diego. Providing secure, yet open, access to real-time and archived data for a broad range of audiences is best served by a series of platform agnostic low-latency web-based applications. We present a framework of tools that interface between the world wide web and Boulder Real Time Technologies Antelope Environmental Monitoring System data acquisition and archival software. These tools provide audiences ranging from network operators and geoscience researchers, to funding agencies and the general public, with comprehensive information about the experiment. This ranges from network-wide to station-specific metadata, state-of-health metrics, event detection rates, archival data and dynamic report generation over a stations two year life span. Leveraging open source web-site development frameworks for both the server side (Perl, Python and PHP) and client-side (Flickr, Google Maps/Earth and jQuery) facilitates the development of a robust extensible architecture that can be tailored on a per-user basis, with rapid prototyping and development that adheres to web-standards.

  8. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Durand, Marie-Jose; Jouanneau, Sulivan; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Dion, Michel [UMR CNRS 6204, Nantes University, PRES UNAM, Biotechnologie, Biocatalyse, Bioregulation, 2, Rue de la Houssiniere, BP 92208, Nantes cedex 3 (France); Pernetti, Mimma; Poncelet, Denis [ONIRIS-ENITIAA, UMR CNRS GEPEA, Rue de la Geraudiere, BP 82225, Nantes cedex 3 (France)

    2011-05-15

    This study describes the construction of inducible bioluminescent strains via genetic engineering along with their characterization and optimization in the detection of heavy metals. Firstly, a preliminary comparative study enabled us to select a suitable carbon substrate from pyruvate, glucose, citrate, diluted Luria-Bertani, and acetate. The latter carbon source provided the best induction ratios for comparison. Results showed that the three constructed inducible strains, Escherichia coli DH1 pBzntlux, pBarslux, and pBcoplux, were usable when conducting a bioassay after a 14-h overnight culture at 30 C. Utilizing these sensors gave a range of 12 detected heavy metals including several cross-detections. Detection limits for each metal were often close to and sometimes lower than the European standards for water pollution. Finally, in order to maintain sensitive bacteria within the future biosensor-measuring cell, the agarose immobilization matrix was compared to polyvinyl alcohol (PVA). Agarose was selected because the detection limits of the bioluminescent strains were not affected, in contrast to PVA. Specific detection and cross-detection ranges determined in this study will form the basis of a multiple metals detection system by the new multi-channel Lumisens3 biosensor. (orig.)

  9. Association of autism tendency and hemodynamic changes in the prefrontal cortex during facial expression stimuli measured by multi-channel near-infrared spectroscopy.

    Science.gov (United States)

    Hosokawa, Mai; Nakadoi, Yoshihiro; Watanabe, Yukina; Sumitani, Satsuki; Ohmori, Tetsuro

    2015-03-01

    The aim of this study is to examine the hemodynamic changes induced by the cognitive process of facial expression by using multi-channel near-infrared spectroscopy in healthy subjects with varying degrees of autism tendency. Subjects were 38 volunteers, 20 men and 18 women. Autism tendency was measured by the Autism Spectrum Quotient. The hemodynamic changes in the prefrontal cortex were measured by 24-channel near-infrared spectroscopy system, while subjects were asked to judge their own emotional response to standardized pictures of eight kinds of facial expressions on a computer screen. There were significant negative correlations between Autism Spectrum Quotient scores and accuracy of fearful expression recognition as well as increases in the concentration of oxygenated hemoglobin in response to four kinds of emotional faces (fear, contempt, sadness and disgust). Our findings suggest that the greater tendency to autism that subjects have, the more difficulty they have in recognizing a fearful expression and the less hemodynamic change in the prefrontal cortex they show in response to negative facial expressions. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.

  10. Generation of multi-channel high-speed physical random numbers originated from two chaotic signals of mutually coupled semiconductor lasers

    Science.gov (United States)

    Tang, X.; Wu, Z. M.; Wu, J. G.; Deng, T.; Fan, L.; Zhong, Z. Q.; Chen, J. J.; Xia, G. Q.

    2015-01-01

    We propose and experimentally demonstrate a novel technique to generate multi-channel high-speed physical random numbers (PRNs) by taking two chaotic signal outputs from mutually coupled semiconductor lasers (MC-SLs) as entropy sources. First, through controlling the operation parameters of the MC-SL system, two time-delay signature (TDS) suppressed chaotic signals can be obtained. Next, each of these two chaotic signals is sampled by an 8 bit analog-to-digital converter (ADC) with a sampling rate of 10 GHz, and then a bitwise exclusive-OR (XOR) operation on the corresponding bits in samples of the chaotic signal and its time delayed signal is implemented to obtain 8 bit XOR data. Furthermore, through selecting the five least significant bits (LSBs) of 8 bit XOR data to form 5 bit Boolean sequences, two sets of PRN streams with a rate up to 50 Gbits s-1 are generated and successfully pass the NIST statistical tests. Finally, merging these two sets of 50 Gbits s-1 PRN streams by an interleaving operation, another set of the 100 Gbits s-1 PRN stream, which meets all the quality criteria of NIST statistical tests, is also acquired.

  11. Development and Experimental Validation of a Dry Non-Invasive Multi-Channel Mouse Scalp EEG Sensor through Visual Evoked Potential Recordings

    Science.gov (United States)

    Kim, Donghyeon; Yeon, Chanmi; Kim, Kiseon

    2017-01-01

    In this paper, we introduce a dry non-invasive multi-channel sensor for measuring brainwaves on the scalps of mice. The research on laboratory animals provide insights to various practical applications involving human beings and other animals such as working animals, pets, and livestock. An experimental framework targeting the laboratory animals has the potential to lead to successful translational research when it closely resembles the environment of real applications. To serve scalp electroencephalography (EEG) research environments for the laboratory mice, the dry non-invasive scalp EEG sensor with sixteen electrodes is proposed to measure brainwaves over the entire brain area without any surgical procedures. We validated the proposed sensor system with visual evoked potential (VEP) experiments elicited by flash stimulations. The VEP responses obtained from experiments are compared with the existing literature, and analyzed in temporal and spatial perspectives. We further interpret the experimental results using time-frequency distribution (TFD) and distance measurements. The developed sensor guarantees stable operations for in vivo experiments in a non-invasive manner without surgical procedures, therefore exhibiting a high potential to strengthen longitudinal experimental studies and reliable translational research exploiting non-invasive paradigms. PMID:28208777

  12. The Role of Alternating Bilateral Stimulation in Establishing Positive Cognition in EMDR Therapy: A Multi-Channel Near-Infrared Spectroscopy Study

    Science.gov (United States)

    Amano, Tamaki; Toichi, Motomi

    2016-01-01

    Eye movement desensitisation and reprocessing (EMDR) is a standard method for treating post-traumatic stress disorder. EMDR treatment consists of desensitisation and resource development and installation (RDI) stages. Both protocols provide a positive alternating bilateral stimulation (BLS). The effect of desensitisation with BLS has been elucidated. However, a role for BLS in RDI remains unknown. Therefore, it is important to measure feelings as subjective data and physiological indicators as objective data to clarify the role of BLS in RDI. RDI was administered to 15 healthy volunteer subjects who experienced pleasant memories. Their oxygenated haemoglobin concentration ([oxy-Hb]), a sensitive index of brain activity, was measured from the prefrontal cortex (PFC) to the temporal cortex using multi-channel near-infrared spectroscopy during recall of a pleasant memory with or without BLS. The BLS used was alternating bilateral tactile stimulation with a vibration machine. The psychological evaluation suggested that RDI was successful. The results showed that, compared with non-BLS conditions, accessibility was increased and subjects were more relaxed under BLS conditions. A significant increase in [oxy-Hb] was detected in the right superior temporal sulcus (STS), and a decrease in the wide bilateral areas of the PFC was observed in response to BLS. The significant BLS-induced activation observed in the right STS, which is closely related to memory representation, suggests that BLS may help the recall of more representative pleasant memories. Furthermore, the significant reduction in the PFC, which is related to emotion regulation, suggests that BLS induces relaxation and comfortable feelings. These results indicate an important neural mechanism of RDI that emotional processing occurred rather than higher cognitive processing during this stage. Considering the neuroscientific evidence to date, BLS in RDI may enhance comfortable feelings about pleasant memories

  13. A signal subspace dimension estimator based on F-norm with application to subspace-based multi-channel speech enhancement

    Institute of Scientific and Technical Information of China (English)

    LI Chao; LIU Wenju

    2012-01-01

    Although the signal subspace approach has been studied extensively for speech enhancement, no good solution has been found to identify signal subspace dimension in multi- channel situation. This paper presents a signal subspace dimension estimator based on F-norm of correlation matrix, with which subspace-based multi-channel speech enhancement is robust to adverse acoustic environments such as room reverberation and low input signal to noise ratio (SNR). Experiments demonstrate the presented method leads to more noise reduction and less speech distortion comparing with traditional methods.

  14. Multi-channel photon migration study in visible Chinese human muscle for optical detection of deep vein thrombosis

    Science.gov (United States)

    Sun, Yunlong; Li, Ting

    2016-03-01

    Deep vein thrombosis (DVT) always induced venous thrombosis. Most cases of venous thrombosis were induced by deep vein thrombosis (DVT), with high incidence rate of >60% in >60 years old people. Near-infrared spectroscopy (NIRS) were reported recently to be an intriguing and potential technique in detecting DVT in clinics. However, the photon transport is still unclear, which is crucial for the image reconstruction of the updated development called as NIRS-based DVT imager. Here we employed the Monte Carlo simulation software for 3D voxelized media (MCVM) and the Visible Chinese Human (VCH) model, which segmentation is finest in the world, to simulate multi-channel photon migration in calf muscle. And the image reconstruction of DVT hemodynamic distribution was achieved. This study, for the first time, provides the most realistic 3-D multichannel photon migration for NIRS study on DVT, and explored the image reconstruction for furtherly developing a NIRS-based DVT imager.

  15. Multi Channels PWM Controller for Thermoelectric Cooler Using a Programmable Logic Device and Lab-Windows CVI

    Directory of Open Access Journals (Sweden)

    Eli FLAXER

    2008-09-01

    Full Text Available We present a complete design of a multi channels PID controller for Thermoelectric Cooler (TEC using a pulse width modulation (PWM technique implemented by a dedicated programmable logic device (PLD programmed by VHDL. The PID control loop is implemented by software written by National Instrument Lab-Windows CVI. Due to the fact that the implementation is by a VHDL and PLD the design is modular, as a result, the circuit is very compact in size and very low cost as compared to any commercial product. In addition, since the control loop is implemented by software running on a personal computer (PC using a C language, it is easy to adjust the controller to various environmental conditions and for a width range of sensors like: a thermo couple (TC, thermistor, resistance temperature detectors (RTD etc. We demonstrate the performance of this circuit as a controller for a small incubator using thermistor as the temperature sensor.

  16. A 1.2 V and 69 mW 60 GHz Multi-channel Tunable CMOS Receiver Design

    Directory of Open Access Journals (Sweden)

    A. Oncu

    2015-04-01

    Full Text Available A multi-channel receiver operating between 56 GHz and 70 GHz for coverage of different 60 GHz bands worldwide is implemented with a 90 nm Complementary Metal-Oxide Semiconductor (CMOS process. The receiver containing an LNA, a frequency down-conversion mixer and a variable gain amplifier incorporating a band-pass filter is designed and implemented. This integrated receiver is tested at four channels of centre frequencies 58.3 GHz, 60.5 GHz, 62.6 GHz and 64.8 GHz, employing a frequency plan of an 8 GHz-intermediate frequency (IF. The achieved conversion gain by coarse gain control is between 4.8 dB–54.9 dB. The millimeter-wave receiver circuit is biased with a 1.2V supply voltage. The measured power consumption is 69 mW.

  17. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    Science.gov (United States)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p heart rate.

  18. HyVE-hybrid vibro-electrotactile stimulation-is an efficient approach to multi-channel sensory feedback.

    Science.gov (United States)

    D'Alonzo, Marco; Dosen, Strahinja; Cipriani, Christian; Farina, Dario

    2014-01-01

    An important reason for the abandonment of commercial actuated hand prostheses by the users is the lack of sensory feedback. Wearable afferent interfaces capable of providing electro- or vibro-tactile stimulation have high potential to restore the missing tactile and/or proprioceptive information to the user. By definition, these devices can elicit single modality (i.e., either vibrotactile or electrotactile) substitute sensations. In a recent research we have presented a novel approach comprising hybrid vibro-electrotactile (HyVE) combined stimulation, in order to provide multimodal sensory feedback. An important advantage of this approach is in the size of the design: the HyVE interface is much more compact than two separated single-modality interfaces, since electro- and vibro-tactile stimulators are placed one on top of the other. The HyVE approach has been previously tested in healthy subjects and has shown to provide a range of hybrid stimuli that could be properly discriminated. However, this approach has never been assessed as a method to provide multi-channel stimuli, i.e., stimuli from a variety of stimulators, mapping information from a multitude of sensors on a prosthesis. In this study, the ability of ten healthy subjects to discriminate stimuli and patterns of stimuli from four different five-channel interfaces applied on their forearms was evaluated. We showed that multiple HyVE units could be used to provide multi-channel sensory information with equivalent performance (∼95 percent for single stimuli and ∼80 percent for pattern) to single modality interfaces (vibro- or electro-tactile) larger in size and with better performance than vibrotactile interfaces (i.e., 73 percent for single stimuli and 69 percent for pattern) with the same size. These results are promising in relation to the current availability of multi-functional prostheses with multiple sensors.

  19. Electrochemical evaluation of chemical selectivity of glutamate receptor ion channel proteins with a multi-channel sensor.

    Science.gov (United States)

    Sugawara, M; Hirano, A; Rehák, M; Nakanishi, J; Kawai, K; Sato, H; Umezawa, Y

    1997-01-01

    A new method for evaluating chemical selectivity of agonists towards receptor ion channel proteins is proposed by using glutamate receptor (GluR) ion channel proteins and their agonists N-methyl-D-aspartic acid (NMDA), L-glutamate, and (2S, 3R, 4S) isomer of 2-(carboxycyclopropyl)glycine (L-CCG-IV). Integrated multi-channel currents, corresponding to the sum of total amount of ions passed through the multiple open channels, were used as a measure of agonists' selectivity to recognize ion channel proteins and induce channel currents. GluRs isolated from rat synaptic plasma membranes were incorporated into planar bilayer lipid membranes (BLMs) formed by the folding method. The empirical factors that affect the selectivity were demonstrated: (i) the number of GluRs incorporated into BLMs varied from one membrane to another; (ii) each BLM contained different subtypes of GluRs (NMDA and/or non-NMDA subtypes); and (iii) the magnitude of multi-channel responses induced by L-glutamate at negative applied potentials was larger than at positive potentials, while those by NMDA and L-CCG-IV were linearly related to applied potentials. The chemical selectivity among NMDA, L-glutamate and L-CCG-IV for NMDA subtype of GluRs was determined with each single BLM in which only NMDA subtype of GluRs was designed to be active by inhibiting the non-NMDA subtypes using a specific antagonist DNQX. The order of selectivity among the relevant agonists for the NMDA receptor subtype was found to be L-CCG-IV > L-glutamate > NMDA, which is consistent with the order of binding affinity of these agonists towards the same NMDA subtypes. The potential use of this approach for evaluating chemical selectivity towards non-NMDA receptor subtypes of GluRs and other receptor ion channel proteins is discussed.

  20. System Driven by Correlated Gaussian Noises Related with Disorder

    Institute of Scientific and Technical Information of China (English)

    LI Jing-Hui

    2007-01-01

    A system driven by correlated Gaussian noises related with disorder is investigated. The Fokker-Planck equation (FPE) for the system is derived. Using the FPE derived, some systems driven by correlated Gaussian noises related with disorder can be investigated for Brownian motors, nonequilibrium transition, resonant activation,stochastic resonance, and so on. We only give one example: i.e., using the FPE derived, we study the resonant activation for a single motor protein model with correlated noises related to disorder. Since the correlated noise related to disorder usually exists with the friction, for the temperature, and so on, our results have generic physical meanings for physics, chemistry, biology and other sciences.

  1. Models of plastic depinning of driven disordered systems

    Indian Academy of Sciences (India)

    M Cristina Marchetti

    2005-06-01

    Two classes of models of driven disordered systems that exhibit history-dependent dynamics are discussed. The first class incorporates local inertia in the dynamics via nonmonotonic stress transfer between adjacent degrees of freedom. The second class allows for proliferation of topological defects due to the interplay of strong disorder and drive. In mean field theory both models exhibit a tricritical point as a function of disorder strength. At weak disorder depinning is continuous and the sliding state is unique. At strong disorder depinning is discontinuous and hysteretic.

  2. Fano interference governs wave transport in disordered systems.

    Science.gov (United States)

    Poddubny, Alexander N; Rybin, Mikhail V; Limonov, Mikhail F; Kivshar, Yuri S

    2012-06-26

    Light localization in disordered systems and Bragg scattering in regular periodic structures are considered traditionally as two entirely opposite phenomena: disorder leads to degradation of coherent Bragg scattering whereas Anderson localization is suppressed by periodicity. Here we reveal a non-trivial link between these two phenomena, through the Fano interference between Bragg scattering and disorder-induced scattering, that triggers both localization and de-localization in random systems. We find unexpected transmission enhancement and spectrum inversion when the Bragg stop-bands are transformed into the Bragg pass-bands solely owing to disorder. Fano resonances are always associated with coherent scattering in regular systems, but our discovery of disorder-induced Fano resonances may provide novel insights into many features of the transport phenomena of photons, phonons, and electrons. Owning to ergodicity, the Fano resonance is a fingerprint feature for any realization of the structure with a certain degree of disorder.

  3. Multi-channel amplitude-integrated EEG characteristics in preterm infants with a normal neurodevelopment at two years of corrected age

    NARCIS (Netherlands)

    Niemarkt, H.J.; Jennekens, W.; Maartens, I.A.; Wassenberg, T.; Aken, M. van; Katgert, T.; Kramer, B.W.; Gavilanes, A.W.; Zimmermann, L.J.; Bambang Oetomo, S.; Andriessen, P.

    2012-01-01

    AIM: To analyze quantitatively multi-channel amplitude-integrated EEG (aEEG) characteristics and assess regional differences. METHODS: We investigated 40 preterm infants (postmenstrual age, PMA: range 27-37 weeks) with normal follow-up at 24 months of age, at a median postnatal age of 8 days using 4

  4. China's first intermediate resolution multi-channel seismic survey in the northern Victoria Land Basin and Terror Rift, Ross Sea, Antarctica

    Science.gov (United States)

    Shen, Zhongyan; Gao, Jinyao; Zhang, Tao; Wang, Wei; Ding, Weifeng; Zhang, Sheng

    2017-04-01

    The West Antarctic Rift System (WARS) represents one of the largest active continental rift systems on Earth and is less well known than other rift systems because it is largely covered by thick ice. The Terror Rift (TR), superimposing on the Victoria Land Basin (VLB) in the western Ross Sea, is identified as the most recent deformational zone of the WARS, thus will provide knowledge of the active deformation process of the WARS. The structure and kinematics of the TR is under debate. Originally, the TR was thought to consist of two parts: the Discovery Graben and the magmatically-intruded Lee Arch. New denser seismic grid in the middle and southern segments of the TR revealed a different structure of the Lee Arch while the northern segment of the TR is not well studied. The glacial history of the VLB/TR region is another attractive issue to the geologists since this area records the behavior information of EAIS and WAIS. In the southern part of the VLB, especially in the McMurdo Sound, the framework of the glacial history is well established after several deep cores which recovery the whole stratigraphic sequences since the onset of the glaciation. However, the glacial history of the northern part of the VLB/TR is less well studied and here we emphasize its importance because the northern part of the VLB/TR is a link between the well-studied southern VLB and the sediment-well-preserved Northern Basin. During the 32nd Chinese National Antarctic Research Expedition, on the board of the RV XueLong, we collected intermediate resolution multi-channel seismic reflection data in the northern VLB/TR. These data will establish new constraints on the timing of deformation, structure and kinematics of the TR, and the history of the EAIS and WAIS.

  5. Analysis and verification of multi-channel FULMS algorithm for adaptive feedforward active vibration control%多通道FULMS自适应前馈振动控制算法分析与验证

    Institute of Scientific and Technical Information of China (English)

    朱晓锦; 黄全振; 高志远; 高守玮; 姜恩宇

    2011-01-01

    One of the key issues for active vibration control of flexible structures is control strategy and method, a multi-channel FULMS algorithm for adaptive feedforward control systems was proposed to solve the problem how to obtain the reference signal of FXLMS algorithm.Based on the controller architecture constructed and illustrated here, the multichannel FULMS algorithm procedure was deduced and described in general.To verify the feasibility and priority of the proposed control algorithm, performance comparisons of single-channel and multi-channel with FXLMS and FULMS were made using MATLAB.The analysis results indicated that the multi-channel control performance is better than the singlechannel one, while FULMS algorithm has better performance than FXLMS algorithm.Finally, taking a piezoelectric flexible epoxide resin plate to simulate solar panels, an active vibration suppression experimental platform was established with its relative measurement and control system.The experimental results showed that the proposed FULMS algorithm is feasible and efficient with excellent convergence and control performance.%柔性结构振动主动控制的核心问题之一是控制策略与方法,针对FXLMS自适应滤波前馈振动控制方法参考信号不易选取问题,给出一种多通道FULMS自适应滤波前馈振动控制方法;首先进行控制器结构的分析与构建,概括描述和推导了多通道FULMS控制算法过程;为验证所分析算法的可行性和优越性,基于MATLAB软件包进行仿真分析,并与FXLMS算法分别进行单通道和多通道控制效果对比,分析结果表明多通道控制优于单通道控制,FULMS算法优于FXIMS算法.在此基础上,以航天器柔性帆板结构为理想模拟对象,构建压电机敏柔性板结构和测控系统进行实际算法控制实验;实验过程与验证结果表明,采用的FULMS控制器设计方法与控制算法是有效可行的,并具有较快的收敛速度和较好的控制效果.

  6. Acquisition and preliminary analysis of multi-channel seismic reflection data, acquired during the oceanographic cruises of the TOMO-ETNA experiment

    Directory of Open Access Journals (Sweden)

    Marco Firetto Carlino

    2016-09-01

    Full Text Available The TOMO-ETNA experiment was performed in the framework of the FP7 “MED-SUV” (MEDiterranean SUpersite Volcanoes in order to gain a detailed geological and structural model of the continental and oceanic crust concerning Etna and Aeolian Islands volcanoes (Sicily, Italy, by means of active and passive seismic exploration methodologies. Among all data collected, some 1410 km of marine multi-channel seismic (MCS reflection profiles were acquired in the Ionian and Tyrrhenian Seas during two of the three oceanographic cruises of the TOMO-ETNA experiment, in July and November 2014, with the aim of shading light to deep, intermediate and shallow stratigraphy and crustal structure of the two above mentioned areas. The MCS sections, targeted to deep exploration, were acquired during the oceanographic cruise on board the R/V “Sarmiento de Gamboa”, using an active seismic source of 16 air-guns, for a total volume of 4340 cu. in., and a 3000 m long, 240-channels digital streamer as receiving system. High-resolution seismic profiles were instead collected through the R/V “Aegaeo”, using two smaller air-guns (overall 270 cu. in. volume and a 96 channels, 300 m long digital streamer. This paper provides a detailed description of the acquisition parameters and main processing steps adopted for the MCS data. Some processed lines are shown and preliminarily interpreted, to highlight the overall good quality and the high potential of the MCS sections collected during the TOMO-ETNA experiment.

  7. A Cenozoic tectono-sedimentary model of the Tainan Basin, the South China Sea: evidence from a multi-channel seismic profile

    Institute of Scientific and Technical Information of China (English)

    Wei-wei DING; Jia-biao LI; Ming-bi LI; Xue-lin QIU; Yin-xia FANG; Yong TANG

    2008-01-01

    The Tainan Basin is one of the set of Cenozoic extensional basins along northern margin of the South China Sea that experienced extension and subsequently thermal subsidence. The Tainan Basin is close to the Taiwan Arc-Trench System and straddles a transition zone between oceanic and continental crust. A new regional multi-channel seismic profile (973-01) across the region of NE South China Sea is introduced in this paper. In seismic stratigraphy and structural geology, a model of Cenozoic tectono-sedimentation of the Tainan Basin is established. The results show that three stages can be suggested in Tainan Basin; In Stage A (Oligocene (?)-Lower Miocene) the stratigraphy shows restricted rifting, indicating crustal extension. Terrestrial sediments mostly filled the faulted sags of the North Depression on the continental shelf~ Structural highs, including the Central Uplift, blocked material transportation to the South Depression in abyssal basin. In Stage B the Tainan Basin (Middle-Upper Miocene) exhibits a broad subsidence resulting from the post-tiffing thermal cooling. The faulted-sags in North Depression had been filled up. Terrestrial materials were transported over the structural highs and deposited directly in the South Depression through submarine gullies or canyons. This sedimentation resulted in a crucial change in the slope to a modern shape. In Stage C (Latesl Miocene-Recent) a phase change from extension to compression took place due to the orogeny caused by the overthrusting of the Luzon volcanic arc. Many inverse structures, such as thrusts, fault bend folds, and a regional unconformity were formed. Forland basin began developing.

  8. Adaptive multi-channel downlink assignment for overloaded spectrum-shared multi-antenna overlaid cellular networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2012-10-19

    Overlaid cellular technology has been considered as a promising candidate to enhance the capacity and extend the coverage of cellular networks, particularly indoors. The deployment of small cells (e.g. femtocells and/or picocells) in an overlaid setup is expected to reduce the operational power and to function satisfactorily with the existing cellular architecture. Among the possible deployments of small-cell access points is to manage many of them to serve specific spatial locations, while reusing the available spectrum universally. This contribution considers the aforementioned scenario with the objective to serve as many active users as possible when the available downlink spectrum is overloaded. The case study is motivated by the importance of realizing universal resource sharing in overlaid networks, while reducing the load of distributing available resources, satisfying downlink multi-channel assignment, controlling the aggregate level of interference, and maintaining desired design/operation requirements. These objectives need to be achieved in distributed manner in each spatial space with as low processing load as possible when the feedback links are capacity-limited, multiple small-cell access points can be shared, and data exchange between access points can not be coordinated. This contribution is summarized as follows. An adaptive downlink multi-channel assignment scheme when multiple co-channel and shared small-cell access points are allocated to serve active users is proposed. It is assumed that the deployed access points employ isotropic antenna arrays of arbitrary sizes, operate using the open-access strategy, and transmit on shared physical channels simultaneously. Moreover, each active user can be served by a single transmit channel per each access point at a time, and can sense the concurrent interference level associated with each transmit antenna channel non-coherently. The proposed scheme aims to identify a suitable subset of transmit channels

  9. Quantum simulation of disordered systems with cold atoms

    Science.gov (United States)

    Garreau, Jean-Claude

    2017-01-01

    This paper reviews the physics of quantum disorder in relation with a series of experiments using laser-cooled atoms exposed to "kicks" of a standing wave, realizing a paradigmatic model of quantum chaos, the kicked rotor. This dynamical system can be mapped onto a tight-binding Hamiltonian with pseudo-disorder, formally equivalent to the Anderson model of quantum disorder, with quantum chaos playing the role of disorder. This provides a very good quantum simulator for the Anderson physics. xml:lang="fr"

  10. Variants of psychiatric disorders in patients with systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    T A Lisitsyna

    2008-01-01

    Full Text Available Objective. To analyze prevalence and structure of psychiatric disorders in pts with systemic lupus erythematosus (SLE examining in the Institute of rheumatology of RAMS. Material and methods. 115 pts with SLE with median age 34 [24; 45] years and median disease duration 8 [4; 17] years were included. SLE activity was assessed with SLEDAI. Psychiatric disorders were diagnosed by a psychiatrist according to ICD-10 using some psychiatric and psychological scales. Results. Psychiatric disorders were revealed in 76 from 115 (66% pts. Anxiety-depressive spectrum disorders prevailed (83%: depressive episode (40%, adjustment disorders (24%, generalized anxiety disorder (10%, dysthymia (9%. Severe cognitive dysfunction was revealed in 7% of pts. Pts with and without psychiatric disorders did not significantly differ in age, sex, duration and activity of the disease, duration of treatment and cumulative dose of prednisolone and cytotoxic drugs. Conclusion. Psychiatric disorders are frequent in pts with SLE (66%. Anxiety-depressive disorders prevail among them (83%. Relationship between SLE and psychiatric disorders requires further examination.

  11. Recent Advances of Multi-Channel Transmission in Metro Access Networks

    Institute of Scientific and Technical Information of China (English)

    H.J.; Thiele; L.E.; Nelson; B.; Eichenbaum; S.K.; Das

    2003-01-01

    We discuss the concept of coarse wavelength-division multiplexing (CWDM) for metro networks. After reviewing the requirements on components such as lasers and fiber, we propose different architectures for a flexible upgrade of existing CWDM systems.

  12. Computerized image analysis of cell-cell interactions in human renal tissue by using multi-channel immunoflourescent confocal microscopy

    Science.gov (United States)

    Peng, Yahui; Jiang, Yulei; Liarski, Vladimir M.; Kaverina, Natalya; Clark, Marcus R.; Giger, Maryellen L.

    2012-03-01

    Analysis of interactions between B and T cells in tubulointerstitial inflammation is important for understanding human lupus nephritis. We developed a computer technique to perform this analysis, and compared it with manual analysis. Multi-channel immunoflourescent-microscopy images were acquired from 207 regions of interest in 40 renal tissue sections of 19 patients diagnosed with lupus nephritis. Fresh-frozen renal tissue sections were stained with combinations of immunoflourescent antibodies to membrane proteins and counter-stained with a cell nuclear marker. Manual delineation of the antibodies was considered as the reference standard. We first segmented cell nuclei and cell membrane markers, and then determined corresponding cell types based on the distances between cell nuclei and specific cell-membrane marker combinations. Subsequently, the distribution of the shortest distance from T cell nuclei to B cell nuclei was obtained and used as a surrogate indicator of cell-cell interactions. The computer and manual analyses results were concordant. The average absolute difference was 1.1+/-1.2% between the computer and manual analysis results in the number of cell-cell distances of 3 μm or less as a percentage of the total number of cell-cell distances. Our computerized analysis of cell-cell distances could be used as a surrogate for quantifying cell-cell interactions as either an automated and quantitative analysis or for independent confirmation of manual analysis.

  13. Gait training assisted by multi-channel functional electrical stimulation early after stroke: study protocol for a randomized controlled trial.

    Science.gov (United States)

    van Bloemendaal, Maijke; Bus, Sicco A; de Boer, Charlotte E; Nollet, Frans; Geurts, Alexander C H; Beelen, Anita

    2016-10-01

    Many stroke survivors suffer from paresis of lower limb muscles, resulting in compensatory gait patterns characterised by asymmetries in spatial and temporal parameters and reduced walking capacity. Functional electrical stimulation has been used to improve walking capacity, but evidence is mostly limited to the orthotic effects of peroneal functional electrical stimulation in the chronic phase after stroke. The aim of this study is to investigate the therapeutic effects of up to 10 weeks of multi-channel functional electrical stimulation (MFES)-assisted gait training on the restoration of spatiotemporal gait symmetry and walking capacity in subacute stroke patients. In a proof-of-principle study with a randomised controlled design, 40 adult patients with walking deficits who are admitted for inpatient rehabilitation within 31 days since the onset of stroke are randomised to either MFES-assisted gait training or conventional gait training. Gait training is delivered in 30-minute sessions each workday for up to 10 weeks. The step length symmetry ratio is the primary outcome. Blinded assessors conduct outcome assessments at baseline, every 2 weeks during the intervention period, immediately post intervention and at 3-month follow-up. This study aims to provide preliminary evidence for the feasibility and effectiveness of MFES-assisted gait rehabilitation early after stroke. Results will inform the design of a larger multi-centre trial. This trial is registered at the Netherlands Trial Register (number NTR4762 , registered 28 August 2014).

  14. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-10-01

    Full Text Available This study presents the use of a multi-channel opto-electronic sensor (OEPS to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA, and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05; a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001; the bias of BAA 0.85 bpm, the standard deviation (SD 9.20 bpm, and the limits of agreement (LOA from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001; the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  15. BDNF gene delivery within and beyond templated agarose multi-channel guidance scaffolds enhances peripheral nerve regeneration

    Science.gov (United States)

    Gao, Mingyong; Lu, Paul; Lynam, Dan; Bednark, Bridget; Campana, W. Marie; Sakamoto, Jeff; Tuszynski, Mark

    2016-12-01

    Objective. We combined implantation of multi-channel templated agarose scaffolds with growth factor gene delivery to examine whether this combinatorial treatment can enhance peripheral axonal regeneration through long sciatic nerve gaps. Approach. 15 mm long scaffolds were templated into highly organized, strictly linear channels, mimicking the linear organization of natural nerves into fascicles of related function. Scaffolds were filled with syngeneic bone marrow stromal cells (MSCs) secreting the growth factor brain derived neurotrophic factor (BDNF), and lentiviral vectors expressing BDNF were injected into the sciatic nerve segment distal to the scaffold implantation site. Main results. Twelve weeks after injury, scaffolds supported highly linear regeneration of host axons across the 15 mm lesion gap. The incorporation of BDNF-secreting cells into scaffolds significantly increased axonal regeneration, and additional injection of viral vectors expressing BDNF into the distal segment of the transected nerve significantly enhanced axonal regeneration beyond the lesion. Significance. Combinatorial treatment with multichannel bioengineered scaffolds and distal growth factor delivery significantly improves peripheral nerve repair, rivaling the gold standard of autografts.

  16. New geological interpretation of multi-channel seismic profiles from the Pacific Margin of the Antarctic Peninsula

    Directory of Open Access Journals (Sweden)

    Okoń Jan

    2016-06-01

    Full Text Available The Polish Geophysical Expedition to West Antarctica in 1979–1980 was carried out by the Institute of Geophysics, Polish Academy of Sciences. Beside deep seismic soundings, 12 multi-channel seismic profiles, with a total length of ca 1000 km have been recorded north and east of the South Shetland Islands and in the Bransfield Strait, but they have never before been completely interpreted and published. All profiles have been processed with modern processing flow including time migration. Profiles crossing the South Shetland Trench revealed distinct reflector inside continental slope, which has been interpreted as border between buried accretionary prism and overlying slope sediments of glacial-marine origin. Profiles in the Bransfield Strait show traces of the Last Glacial Maximum (LGM in the form of glacial foreground valleys, with some of them used as weak spots for young age volcanic intrusions. This paper is the first comprehensive geological interpretation of collected dataset and differences between results from other expeditions are discussed.

  17. A 12-bit 1 MS/s SAR-ADC for multi-channel CdZnTe detectors

    Science.gov (United States)

    Wei, Liu; Tingcun, Wei; Bo, Li; Panjie, Guo; Yongcai, Hu

    2015-04-01

    This paper presents a low power, area-efficient and radiation-hardened 12-bit 1 MS/s successive approximation register (SAR) analog-to-digital converter (ADC) for multi-channel CdZnTe (CZT) detector applications. In order to improve the SAR-ADC's accuracy, a novel comparator is proposed in which the offset voltage is self-calibrated and also a new architecture for the unit capacitor array is proposed to reduce the capacitance mismatches in the charge-redistribution DAC. The ability to radiation-harden the SAR-ADC is enhanced through circuit and layout design technologies. The prototype chip was fabricated using a TSMC 0.35 μm 2P4M CMOS process. At a 3.3/5 V power supply and a sampling rate of 1 MS/s, the proposed SAR-ADC achieves a peak signal to noise and distortion ratio (SINAD) of 67.64 dB and consumes only 10 mW power. The core of the prototype chip occupies an active area of 1180 × 1080 μm2. Project supported by the Special-Funded Program on National Key Scientific Instruments and Equipment Development (No. 2011YQ040082).

  18. Do you see what I hear: experiments in multi-channel sound and 3D visualization for network monitoring?

    Science.gov (United States)

    Ballora, Mark; Hall, David L.

    2010-04-01

    Detection of intrusions is a continuing problem in network security. Due to the large volumes of data recorded in Web server logs, analysis is typically forensic, taking place only after a problem has occurred. This paper describes a novel method of representing Web log information through multi-channel sound, while simultaneously visualizing network activity using a 3-D immersive environment. We are exploring the detection of intrusion signatures and patterns, utilizing human aural and visual pattern recognition ability to detect intrusions as they occur. IP addresses and return codes are mapped to an informative and unobtrusive listening environment to act as a situational sound track of Web traffic. Web log data is parsed and formatted using Python, then read as a data array by the synthesis language SuperCollider [1], which renders it as a sonification. This can be done either for the study of pre-existing data sets or in monitoring Web traffic in real time. Components rendered aurally include IP address, geographical information, and server Return Codes. Users can interact with the data, speeding or slowing the speed of representation (for pre-existing data sets) or "mixing" sound components to optimize intelligibility for tracking suspicious activity.

  19. Spectrum-efficient multi-channel design for coexisting IEEE 802.15.4 networks: A stochastic geometry approach

    KAUST Repository

    Elsawy, Hesham

    2014-07-01

    For networks with random topologies (e.g., wireless ad-hoc and sensor networks) and dynamically varying channel gains, choosing the long term operating parameters that optimize the network performance metrics is very challenging. In this paper, we use stochastic geometry analysis to develop a novel framework to design spectrum-efficient multi-channel random wireless networks based on the IEEE 802.15.4 standard. The proposed framework maximizes both spatial and time domain frequency utilization under channel gain uncertainties to minimize the number of frequency channels required to accommodate a certain population of coexisting IEEE 802.15.4 networks. The performance metrics are the outage probability and the self admission failure probability. We relax the single channel assumption that has been used traditionally in the stochastic geometry analysis. We show that the intensity of the admitted networks does not increase linearly with the number of channels and the rate of increase of the intensity of the admitted networks decreases with the number of channels. By using graph theory, we obtain the minimum required number of channels to accommodate a certain intensity of coexisting networks under a self admission failure probability constraint. To this end, we design a superframe structure for the coexisting IEEE 802.15.4 networks and a method for time-domain interference alignment. © 2002-2012 IEEE.

  20. Vehicular Networking Enhancement And Multi-Channel Routing Optimization, Based on Multi-Objective Metric and Minimum Spanning Tree

    Directory of Open Access Journals (Sweden)

    Peppino Fazio

    2013-01-01

    Full Text Available Vehicular Ad hoc NETworks (VANETs represent a particular mobile technology that permits the communication among vehicles, offering security and comfort. Nowadays, distributed mobile wireless computing is becoming a very important communications paradigm, due to its flexibility to adapt to different mobile applications. VANETs are a practical example of data exchanging among real mobile nodes. To enable communications within an ad-hoc network, characterized by continuous node movements, routing protocols are needed to react to frequent changes in network topology. In this paper, the attention is focused mainly on the network layer of VANETs, proposing a novel approach to reduce the interference level during mobile transmission, based on the multi-channel nature of IEEE 802.11p (1609.4 standard. In this work a new routing protocol based on Distance Vector algorithm is presented to reduce the delay end to end and to increase packet delivery ratio (PDR and throughput in VANETs. A new metric is also proposed, based on the maximization of the average Signal-to-Interference Ratio (SIR level and the link duration probability between two VANET nodes. In order to relieve the effects of the co-channel interference perceived by mobile nodes, transmission channels are switched on a basis of a periodical SIR evaluation. A Network Simulator has been used for implementing and testing the proposed idea.

  1. Ultrasonic inspection of rocket fuel model using laminated transducer and multi-channel step pulser

    Science.gov (United States)

    Mihara, T.; Hamajima, T.; Tashiro, H.; Sato, A.

    2013-01-01

    For the ultrasonic inspection for the packing of solid fuel in a rocket booster, an industrial inspection is difficult. Because the signal to noise ratio in ultrasonic inspection of rocket fuel become worse due to the large attenuation even using lower frequency ultrasound. For the improvement of this problem, we tried to applied the two techniques in ultrasonic inspection, one was the step function pulser system with the super wideband frequency properties and the other was the laminated element transducer. By combining these two techniques, we developed the new ultrasonic measurement system and demonstrated the advantages in ultrasonic inspection of rocket fuel model specimen.

  2. Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight

    DEFF Research Database (Denmark)

    Elyas, Eli; Grimwood, Alex; Erler, Janine Terra

    2017-01-01

    a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA) was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method) and compared...

  3. A multi-channel S-band FMCW radar front-end

    NARCIS (Netherlands)

    Maas, A.P.M.; Vliet, F.E. van

    2008-01-01

    This paper describes the design and performance of a low-cost synthesized FMCW radar module, operating in S band. The bi-layer PCB contains a frequency-agile low phase-noise synthesizer and three identical coherent receive-channels. The transmit channel has an automatic power control system that red

  4. Detection Optimization of the Progressive Multi-Channel Correlation Algorithm Used in Infrasound Nuclear Treaty Monitoring

    Science.gov (United States)

    2013-03-01

    ultimately improved the quality of this written document . Anthony M. Runco, Jr. vii Table of Contents Page Abstract...Centre IMS International Monitoring System LANL Los Alamos National Laboratory LRT Likelihood ratio test LTA Long-term-power-average MAP Maximum a...station performance. The document then concludes with recommendations for future work. 6 II. Literature Review 2.1

  5. Level-Statistics of Disordered Systems: a Single Parametric Formulation

    OpenAIRE

    Shukla, Pragya

    2002-01-01

    We find that the statistics of levels undergoing metal-insulator transition in systems with multi-parametric Gaussian disorders behaves in a way similar to that of the single parametric Brownian ensembles. The latter appear during aPoisson $\\to$ Wigner-Dyson transition, driven by a random perturbation. The analogy provides the analytical evidence for the single parameter scaling behaviour in disordered systems as well as a tool to obtain the level-correlations at the critical point for a wide...

  6. Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, L., E-mail: lschmitz@ucla.edu; Peebles, W. A. [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095 (United States); Ruskov, E. [Department of Physics and Astronomy, University of California, Irvine, Irvine, California 92697 (United States); Deng, B. H.; Gota, H.; Gupta, D.; Tuszewski, M.; Douglass, J.; Binderbauer, M.; Tajima, T. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2014-11-15

    A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρ{sub s} ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3–5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10{sup 13} ≤ n{sub e} ≤ 1 × 10{sup 14} cm{sup −3}, and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

  7. Multi-channel S-matrices from energy levels in finite boxes

    CERN Document Server

    Berkowitz, Evan; Jefferson, Patrick

    2012-01-01

    We show that for a generic quantum mechanical system with more than one open scattering channel, it is not possible to fully reconstruct the theory's S-matrix from spectral information obtained in large finite volumes with periodic boundary conditions. Physically distinct S-matrices can have identical finite-volume spectra for large finite boxes of arbitrary sizes. If the theory is not time-reversal symmetric, there exists an uncountably infinite set of distinct S-matrices with the same spectra. If the theory respects time-reversal symmetry there exists a discrete set of S-matrices with identical energy levels for finite boxes. We illustrate the issue for simple quantum mechanical systems in 1+1 dimensions.

  8. Multi-channel transmit/receive metal detector coil design for vehicular applications

    Science.gov (United States)

    Yesil, Mehmet Ali; Yeǧin, Korkut; Bellikli, Hasan; Tura, Levent; Nazlı, Hakki; Daǧ, Mahmut

    2014-05-01

    Metal detector coil design has been matured to great extent over the years. However, vehicle mounted or remotely operated metal detectors require different specifications and these specifications dictate multiple transmit and receive coils operating in various settings. Unlike handheld operation, detector is more susceptible to metallic body of the vehicle. Moreover, ground calibration is also different than handheld devices. Coil geometries and intercoupling between them play a significant role in system design and performance. In this study, we study different coil geometries for vehicular applications. Starting from well-known coil geometries, we placed coils on dry, wet and ferrous soil to understand the interaction mechanism. Simulation studies are performed in frequency domain but the results are all applicable to time domain pulse based detector systems.

  9. Multi-channel peristaltic pump for microfluidic applications featuring monolithic PDMS inlay

    DEFF Research Database (Denmark)

    Skafte-Pedersen, Peder; Sabourin, David; Dufva, Martin

    2009-01-01

    The design, fabrication and characterization of a miniaturized, mechanically-actuated 12-channel peristaltic pump for microfluidic applications and built from simple, low-cost materials and fabrication methods is presented. Two pump configurations are tested, including one which reduces pulsating...... flow. Both use a monolithic PDMS pumping inlay featuring three-dimensional geometries favourable to pumping applications and 12 wholly integrated circular channels. Flow rates in the sub-µL min-1 to µL min-1 range were obtained. Channel-to-channel flow rate variability was comparable to a commercial...... pumping system at lower flow rates. The small footprint, 40 mm by 80 mm, of the micropump renders it portable, and allows its use on microscope stages adjacent to microfluidic devices, thus reducing system dead volumes. The micropump's design allows potential use in remote and resource-limited locations...

  10. Optimal Spectrum Access for Users in Multi-Channel Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Vivek Agrawal

    2013-09-01

    Full Text Available Cognitive Radio, a software defined radio, is an emerging technology which uses opportunistic spectrum access (OSA for the efficient utilization of the spectrum. Its main aim is to utilize the unused portions of the spectrum by allowing unlicensed users (secondary users to transmit data in absence of primary users. In this paper the assignment of multiple primary and secondary users in a multiple channel system is addressed with the sole aim of optimizing the total throughput. We have considered an optimal spectrum access (OSA algorithm for the allotment of both the primary and secondary users in a multiple channel system and compared the results with the well-known meta-heuristic techniques such as Simulated Annealing (SA and Tabu Search (TS. The results reveal that OSA algorithm is more efficient as compared to SA and TS as far as throughput optimization is considered.

  11. Optical transmission modules for multi-channel superconducting quantum interference device readouts

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin-Mok, E-mail: jmkim@kriss.re.kr; Kwon, Hyukchan; Yu, Kwon-kyu; Lee, Yong-Ho; Kim, Kiwoong [Brain Cognition Measurement Center, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

    2013-12-15

    We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

  12. Investigating multi-channel quantum tunneling in heavy-ion fusion reactions with Bayesian spectral decomposition

    CERN Document Server

    Hagino, K

    2016-01-01

    Excitations of colliding nuclei during a nuclear reaction considerably affect fusion cross sections at energies around the Coulomb barrier. It has been demonstrated that such channel coupling effects can be represented in terms of a distribution of multiple fusion barriers. We here apply a Bayesian approach to analyze the so called fusion barrier distributions. This method determines simultaneously the barrier parameters and the number of barriers. We particularly investigate the $^{16}$O+$^{144}$Sm and $^{16}$O+$^{154}$Sm systems in order to demonstrate the effectiveness of the method. The present analysis indicates that the fusion barrier distribution for the former system is most consistent with three fusion barriers, even though the experimental data show only two distinct peaks.

  13. Combined Base Station Association and Power Control in Multi-channel Cellular Networks

    CERN Document Server

    Singh, Chandramani; Sundaresan, Rajesh

    2011-01-01

    A combined base station association and power control problem is studied for the uplink of multichannel multicell cellular networks, in which each channel is used by exactly one cell (i.e., base station). A distributed association and power update algorithm is proposed and shown to converge to a Nash equilibrium of a noncooperative game. We consider network models with discrete mobiles (yielding an atomic congestion game), as well as a continuum of mobiles (yielding a population game). We find that the equilibria need not be Pareto efficient, nor need they be system optimal. To address the lack of system optimality, we propose pricing mechanisms. It is shown that these mechanisms can be implemented in a distributed fashion.

  14. Multi-channel peristaltic pump for microfluidic applications featuring monolithic PDMS inlay

    DEFF Research Database (Denmark)

    Skafte-Pedersen, Peder; Sabourin, David; Dufva, Martin

    2009-01-01

    The design, fabrication and characterization of a miniaturized, mechanically-actuated 12-channel peristaltic pump for microfluidic applications and built from simple, low-cost materials and fabrication methods is presented. Two pump configurations are tested, including one which reduces pulsating...... flow. Both use a monolithic PDMS pumping inlay featuring three-dimensional geometries favourable to pumping applications and 12 wholly integrated circular channels. Flow rates in the sub-µL min-1 to µL min-1 range were obtained. Channel-to-channel flow rate variability was comparable to a commercial...... pumping system at lower flow rates. The small footprint, 40 mm by 80 mm, of the micropump renders it portable, and allows its use on microscope stages adjacent to microfluidic devices, thus reducing system dead volumes. The micropump's design allows potential use in remote and resource-limited locations...

  15. Optical transmission modules for multi-channel superconducting quantum interference device readouts

    Science.gov (United States)

    Kim, Jin-Mok; Kwon, Hyukchan; Yu, Kwon-kyu; Lee, Yong-Ho; Kim, Kiwoong

    2013-12-01

    We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

  16. Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration.

    Science.gov (United States)

    Schmitz, L; Ruskov, E; Deng, B H; Gota, H; Gupta, D; Tuszewski, M; Douglass, J; Peebles, W A; Binderbauer, M; Tajima, T

    2014-11-01

    A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρs ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3-5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10(13) ≤ ne ≤ 1 × 10(14) cm(-3), and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

  17. Reaction Mechanism of the Multi-channel Decomposition Reactions of 1-Pentenyl Free Radicals

    Institute of Scientific and Technical Information of China (English)

    CHENG,Xue-Li; ZHAO,Yan-Yun; LI,Feng; LI,Li-Qing; TAO,Xiu-Jun

    2008-01-01

    The reactions of 1-pentenyl decomposition system have been studied extensively at the B3LYP/6-311++G** level with Gaussion 98 package. The potential energy surface with zero-point energy correction was drawn. All reaction channels were fully investigated with the vibrational mode analysis, frontier orbital analysis and electron population analysis to confirm the transition states and reveal the reaction mechanism.

  18. Design and Development of Low Cost Multi-Channel USB Data

    OpenAIRE

    2012-01-01

    This paper describes the design and development of low cost USB Data Acquisition System (DAS) for the measurement of physical parameters. Physical parameters such as temperature, humidity, light intensity etc., which are generally slowly varying signals are sensed by respective sensors or integrated sensors and converted into voltages. The DAS is designed using PIC18F4550 microcontroller, communicating with Personal Computer (PC) through USB (Universal Serial Bus). The designed DAS has been t...

  19. Development of Efficient FPGA-Based Multi-Channel Phase Meters for IR-Interferometers

    OpenAIRE

    Esteban Hernandez, Luis; Sanchez, Miguel; López Martín, Juan Antonio; Kornejew, Petra; Hirsch, Matthias; Nieto-Taladriz García, Octavio

    2011-01-01

    Infrared (IR) interferometry is a method for measuring the line-electron density of fusion plasmas. The significant performance achieved by FPGAs in solving digital signal processing tasks advocates the use of this type of technology in two-color IR interferometers of modern stellarators, such as the TJ-II (Madrid, Spain) and the future W7-X (Greifswald, Germany). In this work the implementation of a line-average electron density measuring system in an FPGA device is described. Several optimi...

  20. Time over threshold based multi-channel LuAG-APD PET detector

    Science.gov (United States)

    Shimazoe, Kenji; Orita, Tadashi; Nakamura, Yasuaki; Takahashi, Hiroyuki

    2013-12-01

    To achieve efficient signal processing, several time-based positron emission tomography (PET) systems using a large number of granulated gamma-ray detectors have recently been proposed. In this work described here, a 144-channel Pr:LuAG avalanche photodiode (APD) PET detector that uses time over threshold (ToT) and pulse train methods was designed and fabricated. The detector is composed of 12×12 Pr:LuAG crystals, each of which produces a 2 mm×2 mm×10 mm pixel individually coupled to a 12×12 APD array, which in turn is connected pixel-by-pixel with one channel of a time over threshold based application-specific integrated circuit (ToT-ASIC) that was designed and fabricated using a 0.25 μm 3.3 V Taiwan Semiconductor Company complementary metal oxide semiconductor (TSMC CMOS) process. The ToT outputs are connected through a field-programmable gate array (FPGA) to a data acquisition (DAQ) system. Three front-end ASIC boards-each incorporating a ToT-ASIC chip, threshold control digital-to-analog converters (DACs), and connectors, and dissipating power at about 230 mW per board-are used to read from the 144-channel LuAG-APD detector. All three boards are connected through an FPGA board that is programmed to calibrate the individual thresholds of the ToT circuits to allow digital multiplexing to form an integrated PET module with a measured timing resolution of 4.2 ns. Images transmitted by this PET system can be successfully acquired through collimation masks. As a further implementation of this technology, an animal PET system consisting of eight gamma pixel modules forming a ring is planned.

  1. Time over threshold based multi-channel LuAG-APD PET detector

    Energy Technology Data Exchange (ETDEWEB)

    Shimazoe, Kenji, E-mail: shimazoe@it-club.jp [Department of Nuclear Engineering and Management, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Orita, Tadashi [Department of Nuclear Engineering and Management, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Nakamura, Yasuaki [Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, Hiroyuki [Department of Nuclear Engineering and Management, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2013-12-11

    To achieve efficient signal processing, several time-based positron emission tomography (PET) systems using a large number of granulated gamma-ray detectors have recently been proposed. In this work described here, a 144-channel Pr:LuAG avalanche photodiode (APD) PET detector that uses time over threshold (ToT) and pulse train methods was designed and fabricated. The detector is composed of 12×12 Pr:LuAG crystals, each of which produces a 2 mm×2 mm×10 mm pixel individually coupled to a 12×12 APD array, which in turn is connected pixel-by-pixel with one channel of a time over threshold based application-specific integrated circuit (ToT-ASIC) that was designed and fabricated using a 0.25 μm 3.3 V Taiwan Semiconductor Company complementary metal oxide semiconductor (TSMC CMOS) process. The ToT outputs are connected through a field-programmable gate array (FPGA) to a data acquisition (DAQ) system. Three front-end ASIC boards—each incorporating a ToT-ASIC chip, threshold control digital-to-analog converters (DACs), and connectors, and dissipating power at about 230 mW per board—are used to read from the 144-channel LuAG-APD detector. All three boards are connected through an FPGA board that is programmed to calibrate the individual thresholds of the ToT circuits to allow digital multiplexing to form an integrated PET module with a measured timing resolution of 4.2 ns. Images transmitted by this PET system can be successfully acquired through collimation masks. As a further implementation of this technology, an animal PET system consisting of eight gamma pixel modules forming a ring is planned.

  2. Dynamic management of multi-channel interfaces for human interactions with computer-based intelligent assistants

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, T.D. Jr.

    1989-01-01

    For complex man-machine tasks where multi-media interaction with computer-based assistants is appropriate, a portion of the assistant's intelligence must be devoted to managing its communication processes with the user. Since people often serve the role of assistants, the conventions of human communication provide a basis for designing the communication processes of the computer-based assistant. Human decision making for communication requires knowledge of the user's style, the task demands, and communication practices, and knowledge of the current situation. Decisions necessary for effective communication, when, how, and what to communicate, can be expressed using these knowledge sources. A system based on human communication rules was developed to manage the communication decisions of an intelligent assistant. The Dynamic Communication Management (DCM) system consists of four components, three models and a manager. The model of the user describes the user's communication preferences for different task situations. The model of the task is used to establish the user's current activity and to describe how communication should be conducted for this activity. The communication model provides the rules needed to make decisions: when to communicate the message, how to present the message to the user, and what information should be communicated. The Communication Manager controls and coordinates these models to conduct all communication with the user. Performance with DCM as the interface to a simulated Flexible Manufacturing System (FMS) control task was established to learn about the potential benefits of the concept.

  3. Design of high-precision and multi-channel radar generator based on AD9959%基才AD9959的高精度多通道雷达信号源设计

    Institute of Scientific and Technical Information of China (English)

    宋征; 许国宏; 李星

    2012-01-01

    In order to ensure precision of power synthesize in phased array radar, a kind of high-precision multi-channel radar generator based on AD9959 is designed. Radar generator use host computer and FPGA to control ad9959 and Produce 32 channel sine wave.linear frequency modulation and encoding and so on, designed a multi--channel signal amplitude and phase measuring and adjustment system using ad8302. The radar generator have been applied in ,project, and the experimental results showed that the radar generator had several advantages such as high frequency stability, high precise of phase amplitude consistency, which fully meet the techinical requirements and performance index of the radar generator in phased array radar.%现代相控阵雷达为了保证空间功率合成精度需要高精度的雷达信号。设计实现了一种以AD9959为核心的高精度多通道雷达信号源。信号源利用多片AD9959产生32路正弦波、线性调频以及相位编码等多种信号形式.并设计采用AD8302对多路信号的幅度和相位进行检测与调整。该信号源已应用实际工程中,现场实验结果表明,该信号源系统产生的高频信号频率稳定度高、相位幅度一致性好,完全满足对信号源的性能指标的要求。

  4. A Multi-channel Double Auction Algorithm Based on Spectrum Heterogeneity%基于频谱异质的多单元双向频谱拍卖算法

    Institute of Scientific and Technical Information of China (English)

    吴晓芳; 周辉

    2016-01-01

    In view of the heterogeneity of spectrum, propose a multi-channel double auction algorithm based on spectrums heterogeneous. Using double auction model, improved the algorithm from two aspects: multi-channel auction and heterogeneous spectrum auction. It allows buyers/sellers to request/provide multiple channels with different center frequencies, consider non-identical conflict relationship to explore spectrum reusability. We prove that the algorithm satisfied the economics properties: truthfulness, individual rationality and budget balance. And the simulation results confirm that our algorithm achieves high auction efficiency and system revenue.%针对频谱资源的异质性,提出一种基于频谱异质的多单元双向频谱拍卖算法.利用双边频谱拍卖模型,从多单元拍卖和异质频谱拍卖2个方面对算法进行改进,允许买家竞买、卖家提供多个不同中心频率的异质信道,实现互不干扰买家间频谱复用.分析证明了该算法满足拍卖机制设计的3个经济学性能:个体理性、收益均衡和真实性.仿真实验结果表明,该算法在频谱拍卖效率和系统收益方面皆有良好表现.

  5. A hazard-independent approach for the standardised multi-channel dissemination of warning messages

    Science.gov (United States)

    Esbri Palomares, M. A.; Hammitzsch, M.; Lendholt, M.

    2012-04-01

    The tsunami disaster affecting the Indian Ocean region on Christmas 2004 demonstrated very clearly the shortcomings in tsunami detection, public warning processes as well as intergovernmental warning message exchange in the Indian Ocean region. In that regard, early warning systems require that the dissemination of early warning messages has to be executed in way that ensures that the message delivery is timely; the message content is understandable, usable and accurate. To that end, diverse and multiple dissemination channels must be used to increase the chance of the messages reaching all affected persons in a hazard scenario. In addition to this, usage of internationally accepted standards for the warning dissemination such as the Common Alerting Protocol (CAP) and Emergency Data Exchange Language (EDXL) Distribution Element specified by the Organization for the Advancement of Structured Information Standards (OASIS) increase the interoperability among different warning systems enabling thus the concept of system-of-systems proposed by GEOSS. The project Distant Early Warning System (DEWS), co-funded by the European Commission under the 6th Framework Programme, aims at strengthening the early warning capacities by building an innovative generation of interoperable tsunami early warning systems based on the above mentioned concepts following a Service-oriented Architecture (SOA) approach. The project focuses on the downstream part of the hazard information processing where customized, user-tailored warning messages and alerts flow from the warning centre to the responsible authorities and/or the public with their different needs and responsibilities. The information logistics services within DEWS generate tailored EDXL-DE/CAP warning messages for each user that must receive the message according to their preferences, e.g., settings for language, interested areas, dissemination channels, etc.. However, the significant difference in the implementation and

  6. An oject oriented environment for multi-channel signal analysis and understanding

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, W.J.; Dowla, F.U. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    We describe an interactive signal analysis an understanding tool for multichannel signals. The system, written entirely in the C++ language, takes full advantage of the modern workstation GUI tools and integrates traditional signal-processing methods with intelligent domain-specific tools for the exploration and analysis of semistructured problems. By semistructured problems, we mean problems that require a high degree of interactive analysis, and further, the analysis steps are highly adaptive. In other words, a finite number of rules cannot be used to obtain a good solution to the problem.

  7. Design, modeling, and analysis of multi-channel demultiplexer/demodulator

    Science.gov (United States)

    Lee, David D.; Woo, K. T.

    1991-01-01

    Traditionally, satellites have performed the function of a simple repeater. Newer data distribution satellite architectures, however, require demodulation of many frequency division multiplexed uplink channels by a single demultiplexer/demodulator unit, baseband processing and routing of individual voice/data circuits, and remodulation into time division multiplexed (TDM) downlink carriers. The TRW MCDD (Multichannel Demultiplexer/Multirate Demodulator) operates on a 37.4 MHz composite input signal. Individual channel data rates are either 64 Kbps or 2.048 Mbps. The wideband demultiplexer divides the input signal into 1.44 MHz segments containing either a single 2.048 Mbps channel or thirty two 64 Kbps channels. In the latter case, the narrowband demultiplexer further divides the single 1.44 MHz wideband channel into thirty two 45 KHz narrowband channels. With this approach the time domain Fast Fourier Transformation (FFT) channelizer processing capacity is matched well to the bandwidth and number of channels to be demultiplexed. By using a multirate demodulator fewer demodulators are required while achieving greater flexibility. Each demodulator can process a wideband channel or thirty two narrowband channels. Either all wideband channels, a mixture of wideband and narrowband channels, or all narrowband channels can be demodulated. The multirate demodulator approach also has lower nonrecurring costs since only one design and development effort is needed. TRW has developed a proof of concept (POC) model which fully demonstrates the signal processing fuctions of MCDD. It is capable of processing either three 2.048 Mbps channels or two 2.048 Mbps channels and thirty two 64 Kbps channels. An overview of important MCDD system engineering issues is presented as well as discussion on some of the Block Oriented System Simulation analyses performed for design verification and selection of operational parameters of the POC model. Systems engineering analysis of the POC

  8. Effects, determination, and correction of count rate nonlinearity in multi-channel analog electron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reber, T. J.; Plumb, N. C.; Waugh, J. A.; Dessau, D. S. [Department of Physics, University of Colorado, Boulder, Colorado 80309-0390 (United States)

    2014-04-15

    Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We focus on a nearly ubiquitous “inverse saturation” nonlinearity that makes the spectra falsely sharp and beautiful. These artificially enhanced spectra limit accurate quantitative analysis of the data, leading to mistaken spectral weights, Fermi energies, and peak widths. We present a method to rapidly detect and correct for this nonlinearity. This algorithm could be applicable for a wide range of nonlinear systems, beyond photoemission spectroscopy.

  9. A Novel Design of Efficient Multi-channel UART Controller Based on FPGA

    Institute of Scientific and Technical Information of China (English)

    HU Zhe; ZHANG Jun; LUO Xi-ling

    2007-01-01

    In traditional universal asynchronous receiver transmitter (UART) controller, the data transmission is inefficient and the data bus utilization ratio is low. A novel design is provided to solve these problems. The architecture of the system is introduced, the flow charts of data processing as well as the implementation state machine are also presented in detail. This paper is concluded by comparing the performance of this design, which is realized on field programmable gate array (FPGA) using Verilog hardware description language (HDL), with other traditional UART controllers.

  10. Developing imaging capabilities of multi-channel detectors comparable to traditional x-ray detector technology for industrial and security applications

    Science.gov (United States)

    Jimenez, Edward S.; Collins, Noelle M.; Holswade, Erica A.; Devonshire, Madison L.; Thompson, Kyle R.

    2016-10-01

    This work will investigate the imaging capabilities of the Multix multi-channel linear array detector and its potential suitability for big-data industrial and security applications versus that which is currently deployed. Multi-channel imaging data holds huge promise in not only finer resolution in materials classification, but also in materials identification and elevated data quality for various radiography and computed tomography applications. The potential pitfall is the signal quality contained within individual channels as well as the required exposure and acquisition time necessary to obtain images comparable to those of traditional configurations. This work will present results of these detector technologies as they pertain to a subset of materials of interest to the industrial and security communities; namely, water, copper, lead, polyethylene, and tin.

  11. Signature of multi-channel interference in high-order harmonic generation from N2 driven by intense mid-infrared pulses

    CERN Document Server

    Li, Guihua; Xie, Xinhua; Xie, Hongqiang; Zeng, Bin; Chu, Wei; Jing, Chenrui; Ni, Jielei; Zhang, Haisu; Liu, Xiaojun; Chen, Jing; Cheng, Ya; Xu, Zhizhan

    2013-01-01

    We investigate the multi-electron dynamics in high-order harmonic generation (HHG) from N2 molecules. Clear spectral minima are observed in the cutoff region at all three mid-infrared wavelengths (i.e., 1300, 1400 and 1500 nm) chosen in our experiment. It is found that the positions of the spectral minima do not depend on the alignment angles of molecules. In addition, the spectral minima shift almost linearly with the increasing laser intensity at all three wavelengths, which provides a strong evidence on the dynamic multi-channel interference origin of these minima. The advantages of observation of dynamic multi-channel interference based on HHG driven by long wavelength lasers are discussed.

  12. Recent Progress of the HL-2A Multi-Channel HCOOH Laser Interferometer/Polarimeter

    Science.gov (United States)

    Li, Yonggao; Zhou, Yan; Deng, Zhongchao; Li, Yuan; Yi, Jiang; Wang, Haoxi

    2015-05-01

    A multichannel methanoic acid (HCOOH, λ = 432.5 μm) laser interferometer/polarimeter is being developed from the previous eight-channel hydrogen cyanide (HCN, λ = 337 μm) laser interferometer in the HL-2A tokamak. A conventional Michelson-type interometer is used for the electron density measurement, and a Dodel-Kunz-type polarimeter is used for the Faraday rotation effect measurement, respectively. Each HCOOH laser can produce a linearly polarized radiation at a power lever of ˜30 mW, and a power stability optical layout of the interferometer/polarimeter has been finished, and the hardware data processing system based on the fast Fourier transform phase-comparator technique is being explored. In order to demonstrate the feasibility of the diagnostic scheme, two associated bench simulation experiments were carried out in the laboratory, in which the plasma was simulated by a piece of polytetrafluoroethene plate, and the Faraday rotation effect was simulated by a rotating half-wave plate. Simulation results agreed well with the initial experimental conditions. At present, the HCOOH laser interferometer/polarimeter system is being assembled on HL-2A, and is planned to be applied in the 2014-2015 experimental campaign. supported by the National Magnetic Confinement Fusion Science Programs of China (Nos. 2010GB101002 and 2014GB109001), and National Natural Science Foundation of China (Nos. 11075048 and 11275059)

  13. Multi-channel, covert, non-line-of-sight UV communication

    Science.gov (United States)

    Geller, Myer

    1994-04-01

    A system enables omnidirectional non-line-of-sight simultaneous communications in a number of frequency separated channels in the ultraviolet spectrum. A plurality of discharge lamps each has at least a single different isotope of mercury for each omnidirectionally radiating a discrete line in the ultraviolet spectrum. Each of the discrete lines in the ultraviolet spectrum is modulated by an on-off sequence generator so that modulated discrete lines transmit communications to a number of receivers randomly disposed in a non-line-of-sight relationship to the discharge lamps. Absorption filters at each receiver contain a quenching gas and all the other isotopes of mercury except the one which generated the modulated discrete line of interest.

  14. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  15. Final Report: A Multi-Channel Recirculating Loop Signal Regenerator for High Frequency Single-Shot Bunch Length Measurement, August 13, 1998 - March 17, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yan

    1999-06-15

    The project is to design and bench test a multi-channel single shot transient electrical or optical pulses or pulse trains. A special gating function has been used to select a specific pulse for detail measurement. A study has been done to learn the dynamic physics in the recirculative loop. The proposed technique has been able to let signal circulate more than 1000 turns in the recirculative loop.

  16. Detection of gear cracks in a complex gearbox of wind turbines using supervised bounded component analysis of vibration signals collected from multi-channel sensors

    Science.gov (United States)

    Li, Zhixiong; Yan, Xinping; Wang, Xuping; Peng, Zhongxiao

    2016-06-01

    In the complex gear transmission systems, in wind turbines a crack is one of the most common failure modes and can be fatal to the wind turbine power systems. A single sensor may suffer with issues relating to its installation position and direction, resulting in the collection of weak dynamic responses of the cracked gear. A multi-channel sensor system is hence applied in the signal acquisition and the blind source separation (BSS) technologies are employed to optimally process the information collected from multiple sensors. However, literature review finds that most of the BSS based fault detectors did not address the dependence/correlation between different moving components in the gear systems; particularly, the popular used independent component analysis (ICA) assumes mutual independence of different vibration sources. The fault detection performance may be significantly influenced by the dependence/correlation between vibration sources. In order to address this issue, this paper presents a new method based on the supervised order tracking bounded component analysis (SOTBCA) for gear crack detection in wind turbines. The bounded component analysis (BCA) is a state of art technology for dependent source separation and is applied limitedly to communication signals. To make it applicable for vibration analysis, in this work, the order tracking has been appropriately incorporated into the BCA framework to eliminate the noise and disturbance signal components. Then an autoregressive (AR) model built with prior knowledge about the crack fault is employed to supervise the reconstruction of the crack vibration source signature. The SOTBCA only outputs one source signal that has the closest distance with the AR model. Owing to the dependence tolerance ability of the BCA framework, interfering vibration sources that are dependent/correlated with the crack vibration source could be recognized by the SOTBCA, and hence, only useful fault information could be preserved in

  17. SAXS from particle and disordered systems

    Energy Technology Data Exchange (ETDEWEB)

    Pajak, L.; Bierska-Piech, B.; Mrowiec-Bialon, J.; Jarzebski, A.B.; Diduszko, R. [Silesian University, Katowice (Poland)

    2005-01-15

    SAXS studies were performed on different porous, disordered materials such as silica and zirconia aerogels, silica xerogels and carbonaceous materials (anthracite and shungite coals, coke, electrode material and activated carbon). These materials feature a variety of nanostructures. The relation between the profiles of the SAXS curves and the nanostructure of the materials was analysed. Fractal geometry proved to be very useful in this analysis. All types of fractality (mass, pore and surface fractality) were found in the materials studied. Porod plots appeared to be very sensitive to the structural details of the scattering objects.

  18. From complex B(1) mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T.

    Science.gov (United States)

    Zhang, Xiaotong; Schmitter, Sebastian; Van de Moortele, Pierre-Francois; Liu, Jiaen; He, Bin

    2013-06-01

    Elevated specific absorption rate (SAR) associated with increased main magnetic field strength remains a major safety concern in ultra-high-field (UHF) magnetic resonance imaging (MRI) applications. The calculation of local SAR requires the knowledge of the electric field induced by radio-frequency (RF) excitation, and the local electrical properties of tissues. Since electric field distribution cannot be directly mapped in conventional MR measurements, SAR estimation is usually performed using numerical model-based electromagnetic simulations which, however, are highly time consuming and cannot account for the specific anatomy and tissue properties of the subject undergoing a scan. In the present study, starting from the measurable RF magnetic fields (B1) in MRI, we conducted a series of mathematical deduction to estimate the local, voxel-wise and subject-specific SAR for each single coil element using a multi-channel transceiver array coil. We first evaluated the feasibility of this approach in numerical simulations including two different human head models. We further conducted experimental study in a physical phantom and in two human subjects at 7T using a multi-channel transceiver head coil. Accuracy of the results is discussed in the context of predicting local SAR in the human brain at UHF MRI using multi-channel RF transmission.

  19. Development of the analog ASIC for multi-channel readout X-ray CCD camera

    CERN Document Server

    Nakajima, Hiroshi; Idehara, Toshihiro; Anabuki, Naohisa; Tsunemi, Hiroshi; Doty, John P; Ikeda, Hirokazu; Katayama, Haruyoshi; Kitamura, Hisashi; Uchihori, Yukio; 10.1016/j.nima.2010.12.174

    2011-01-01

    We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed ...

  20. XPS: A multi-channel preamplifier shaper IC for X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Krieger, B.; Kipnis, I.; Ludewigt, B.A.

    1997-11-01

    An integrated circuit featuring 48 channels of charge-sensitive preamplifiers followed by variable-gain pulse shaping amplifiers is being developed as part of an x-ray spectrometer with a highly segmented detector to handle high fluxes in synchrotron experiments. Such detector systems can provide excellent energy resolution combined with one-dimensional spatial information. The IC combines many basic spectroscopy amplifier functions with a low-noise preamplifier section to produce a unique circuit capable of driving conventional ADC modules directly. An important feature of the design is the novel CR-RC{sup 2} pulse shaper. In this section, high-linearity transconductor circuits are required in order to provide a broad range of continuously variable peaking times while still maintaining the linearity and noise performance necessary for x-ray spectroscopy. Reported here are first measurements made on the performance of a 16-channel prototype integrated circuit. At present, the preamplifier-shaper circuit achieves an equivalent input noise of 26 electrons rms at 2 {micro}s peaking time with a 0.2 pF external capacitor, which is similar to the capacitance of a single detector element. The design was fabricated in standard 1.2 {micro}m CMOS technology.

  1. High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA

    Science.gov (United States)

    Taylor, Gregory H.

    2012-01-01

    Analog-to-digital converters (ADCs) are used in scientific and communications instruments on all spacecraft. As data rates get higher, and as the transition is made from parallel ADC designs to high-speed, serial, low-voltage differential signaling (LVDS) designs, the need will arise to interface these in field programmable gate arrays (FPGAs). As Xilinx has released the radiation-hardened version of the Virtex-5, this will likely be used in future missions. High-speed serial ADCs send data at very high rates. A de-serializer instantiated in the fabric of the FPGA could not keep up with these high data rates. The Virtex-5 contains primitives designed specifically for high-speed, source-synchronous de-serialization, but as supported by Xilinx, can only support bitwidths of 10. Supporting bit-widths of 12 or more requires the use of the primitives in an undocumented configuration, a non-trivial task. A new SystemVerilog design was written that is simpler and uses fewer hardware resources than the reference design described in Xilinx Application Note XAPP866. It has been shown to work in a Xilinx XC5VSX24OT connected to a MAXIM MAX1438 12-bit ADC using a 50-MHz sample clock. The design can be replicated in the FPGA for multiple ADCs (four instantiations were used for a total of 28 channels).

  2. TARGET: A multi-channel digitizer chip for very-high-energy gamma-ray telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Bechtol, K.; Funk, S.; /Stanford U., HEPL /KIPAC, Menlo Park; Okumura, A.; /JAXA, Sagamihara /Stanford U., HEPL /KIPAC, Menlo Park; Ruckman, L.; /Hawaii U.; Simons, A.; Tajima, H.; Vandenbroucke, J.; /Stanford U., HEPL /KIPAC, Menlo Park; Varner, G.; /Hawaii U.

    2011-08-11

    The next-generation very-high-energy (VHE) gamma-ray observatory, the Cherenkov Telescope Array, will feature dozens of imaging atmospheric Cherenkov telescopes (IACTs), each with thousands of pixels of photosensors. To be affordable and reliable, reading out such a mega-channel array requires event recording technology that is highly integrated and modular, with a low cost per channel. We present the design and performance of a chip targeted to this application: the TeV Array Readout with GSa/s sampling and Event Trigger (TARGET). This application-specific integrated circuit (ASIC) has 16 parallel input channels, a 4096-sample buffer for each channel, adjustable input termination, self-trigger functionality, and tight window-selected readout. We report the performance of TARGET in terms of sampling frequency, power consumption, dynamic range, current-mode gain, analog bandwidth, and cross talk. The large number of channels per chip allows a low cost per channel ($10 to $20 including front-end and back-end electronics but not including photosensors) to be achieved with a TARGET-based IACT readout system. In addition to basic performance parameters of the TARGET chip itself, we present a camera module prototype as well as a second-generation chip (TARGET 2), both of which have been produced.

  3. Multi-channel Opportunistic Access: A Case of Restless Bandits with Multiple Plays

    CERN Document Server

    Ahmad, Sahand Haji Ali

    2009-01-01

    This paper considers the following stochastic control problem that arises in opportunistic spectrum access: a system consists of n channels (Gilbert-Elliot channels)where the state (good or bad) of each channel evolves as independent and identically distributed Markov processes. A user can select exactly k channels to sense and access (based on the sensing result) in each time slot. A reward is obtained whenever the user senses and accesses a good channel. The objective is to design a channel selection policy that maximizes the expected discounted total reward accrued over a finite or infinite horizon. In our previous work we established the optimality of a greedy policy for the special case of k = 1 (i.e., single channel access) under the condition that the channel state transitions are positively correlated over time. In this paper we show under the same condition the greedy policy is optimal for the general case of k >= 1; the methodology introduced here is thus more general. This problem may be viewed as ...

  4. Evolutionary Algorithm Based Feature Optimization for Multi-Channel EEG Classification

    Science.gov (United States)

    Wang, Yubo; Veluvolu, Kalyana C.

    2017-01-01

    The most BCI systems that rely on EEG signals employ Fourier based methods for time-frequency decomposition for feature extraction. The band-limited multiple Fourier linear combiner is well-suited for such band-limited signals due to its real-time applicability. Despite the improved performance of these techniques in two channel settings, its application in multiple-channel EEG is not straightforward and challenging. As more channels are available, a spatial filter will be required to eliminate the noise and preserve the required useful information. Moreover, multiple-channel EEG also adds the high dimensionality to the frequency feature space. Feature selection will be required to stabilize the performance of the classifier. In this paper, we develop a new method based on Evolutionary Algorithm (EA) to solve these two problems simultaneously. The real-valued EA encodes both the spatial filter estimates and the feature selection into its solution and optimizes it with respect to the classification error. Three Fourier based designs are tested in this paper. Our results show that the combination of Fourier based method with covariance matrix adaptation evolution strategy (CMA-ES) has the best overall performance. PMID:28203141

  5. Multi-channel 1-to-2 transition amplitudes in a finite volume

    Energy Technology Data Exchange (ETDEWEB)

    Briceno, Raul [JLAB; Hansen, Maxwell [Helmholtz Institute Mainz; Walker-Loud, Andre P [W& M. JLAB

    2015-04-01

    We derive a model-independent expression for finite-volume matrix elements. Specifically, we present a relativistic, non-perturbative analysis of the matrix element of an external current between a one-scalar in-state and a two-scalar out-state. Our result, which is valid for energies below higher-particle inelastic thresholds, generalizes the Lellouch-Luscher formula in two ways: we allow the external current to inject arbitrary momentum into the system and we allow for the final state to be composed an arbitrary number of strongly coupled two-particle states with arbitrary partial waves (including partial-wave mixing induced by the volume). We also illustrate how our general result can be applied to some key examples, such as heavy meson decays and meson photo production. Finally, we point out complications that arise involving unstable resonance states, such as B to K*+l+l when staggered or mixed-action/partially-quenched calculations are performed.

  6. Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight

    Science.gov (United States)

    Elyas, Eli; Grimwood, Alex; Erler, Janine T.; Robinson, Simon P.; Cox, Thomas R.; Woods, Daniel; Clowes, Peter; De Luca, Ramona; Marinozzi, Franco; Fromageau, Jérémie; Bamber, Jeffrey C.

    2017-01-01

    Elastography, the imaging of elastic properties of soft tissues, is well developed for macroscopic clinical imaging of soft tissues and can provide useful information about various pathological processes which is complementary to that provided by the original modality. Scaling down of this technique should ply the field of cellular biology with valuable information with regard to elastic properties of cells and their environment. This paper evaluates the potential to develop such a tool by modifying a commercial optical coherence tomography (OCT) device to measure the speed of shear waves propagating in a three-dimensional (3D) medium. A needle, embedded in the gel, was excited to vibrate along its long axis and the displacement as a function of time and distance from the needle associated with the resulting shear waves was detected using four M-mode images acquired simultaneously using a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA) was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method) and compared with the shear-wave speed determined from positional differences of TOA for a single channel over multiple bursts (the absolute TOA method). For homogeneous gels the relative method provided shear-wave speed with acceptable precision and accuracy when judged against the expected linear dependence of shear modulus on gelatine concentration (R2 = 0.95) and ultimate resolution capabilities limited by 184μm inter-channel distance. This overall approach shows promise for its eventual provision as a research tool in cancer cell biology. Further work is required to optimize parameters such as vibration frequency, burst length and amplitude, and to assess the lateral and axial resolutions of this type of device as well as to create 3D elastograms. PMID:28107368

  7. Moving beyond sequential design: Reflections on a rich multi-channel approach to data visualization.

    Science.gov (United States)

    Wood, Jo; Beecham, Roger; Dykes, Jason

    2014-12-01

    We reflect on a four-year engagement with transport authorities and others involving a large dataset describing the use of a public bicycle-sharing scheme. We describe the role visualization of these data played in fostering engagement with policy makers, transport operators, the transport research community, the museum and gallery sector and the general public. We identify each of these as `channels'--evolving relationships between producers and consumers of visualization--where traditional roles of the visualization expert and domain expert are blurred. In each case, we identify the different design decisions that were required to support each of these channels and the role played by the visualization process. Using chauffeured interaction with a flexible visual analytics system we demonstrate how insight was gained by policy makers into gendered spatio-temporal cycle behaviors, how this led to further insight into workplace commuting activity, group cycling behavior and explanations for street navigation choice. We demonstrate how this supported, and was supported by, the seemingly unrelated development of narrative-driven visualization via TEDx, of the creation and the setting of an art installation and the curating of digital and physical artefacts. We assert that existing models of visualization design, of tool/technique development and of insight generation do not adequately capture the richness of parallel engagement via these multiple channels of communication. We argue that developing multiple channels in parallel opens up opportunities for visualization design and analysis by building trust and authority and supporting creativity. This rich, non-sequential approach to visualization design is likely to foster serendipity, deepen insight and increase impact.

  8. Chemotherapeutic (cyclophosphamide) effects on rat breast tumor hemodynamics monitored by multi-channel NIRS

    Science.gov (United States)

    Kim, Jae G.; Zhao, Dawen; Mason, Ralph P.; Liu, Hanli

    2005-04-01

    We previously suggested that the two time constants quantified from the increase of tumor oxyhemoglobin concentration, ▵ [HbO2], during hyperoxic gas intervention are associated with two blood flow/perfusion rates in well perfused and poorly perfused regions of tumors. In this study, our hypothesis is that when cancer therapy is applied to a tumor, changes in blood perfusion will occur and be detected by the NIRS. For experiments, systemic chemotherapy, cyclophosphamide (CTX), was applied to two groups of rats bearing syngeneic 13762NF mammary adenocarcinomas: one group received a single high dose i. p. (200 mg/kg CTX) and the other group continuous low doses (20 mg/kg CTX i. p. for 10 days). Time courses of changes in tumor ▵ [HbO2] were measured at four different locations on the breast tumors non-invasively with an inhaled gas sequence of air-oxygen-air before and after CTX administration. Both rat body weight and tumor volume decreased after administration of high dose CTX, but continuous low doses showed decrease of tumor volume only. Baselines (without any therapy) intra- and inter-tumor heterogeneity of vascular oxygenation during oxygen inhalation were similar to our previous observations. After CTX treatment, significant changes in vascular hemodynamic response to oxygen inhalation were observed from both groups. By fitting the increase of ▵ [HbO2] during oxygen inhalation, we have obtained changes of vascular structure ratio and also of perfusion rate ratio before and after chemotherapy. The preliminary results suggest that cyclophosphamide has greatest effect on the well perfused tumor vasculature. Overall, our study supports our earlier hypothesis, proving that the effects of chemotherapy in tumor may be monitored non-invasively by using NIRS to detect changes of hemodynamics induced with respiratory challenges.

  9. Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography.

    Directory of Open Access Journals (Sweden)

    Marco Gazzoni

    Full Text Available The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1 the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2 the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1 it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2 hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.

  10. Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography.

    Science.gov (United States)

    Gazzoni, Marco; Celadon, Nicolò; Mastrapasqua, Davide; Paleari, Marco; Margaria, Valentina; Ariano, Paolo

    2014-01-01

    The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.

  11. Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight.

    Science.gov (United States)

    Elyas, Eli; Grimwood, Alex; Erler, Janine T; Robinson, Simon P; Cox, Thomas R; Woods, Daniel; Clowes, Peter; De Luca, Ramona; Marinozzi, Franco; Fromageau, Jérémie; Bamber, Jeffrey C

    2017-01-01

    Elastography, the imaging of elastic properties of soft tissues, is well developed for macroscopic clinical imaging of soft tissues and can provide useful information about various pathological processes which is complementary to that provided by the original modality. Scaling down of this technique should ply the field of cellular biology with valuable information with regard to elastic properties of cells and their environment. This paper evaluates the potential to develop such a tool by modifying a commercial optical coherence tomography (OCT) device to measure the speed of shear waves propagating in a three-dimensional (3D) medium. A needle, embedded in the gel, was excited to vibrate along its long axis and the displacement as a function of time and distance from the needle associated with the resulting shear waves was detected using four M-mode images acquired simultaneously using a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA) was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method) and compared with the shear-wave speed determined from positional differences of TOA for a single channel over multiple bursts (the absolute TOA method). For homogeneous gels the relative method provided shear-wave speed with acceptable precision and accuracy when judged against the expected linear dependence of shear modulus on gelatine concentration (R2 = 0.95) and ultimate resolution capabilities limited by 184μm inter-channel distance. This overall approach shows promise for its eventual provision as a research tool in cancer cell biology. Further work is required to optimize parameters such as vibration frequency, burst length and amplitude, and to assess the lateral and axial resolutions of this type of device as well as to create 3D elastograms.

  12. Application of multi-channel buffered serial port in data transmission%McBSP技术在数据传输中的应用

    Institute of Scientific and Technical Information of China (English)

    高峰; 王学通

    2011-01-01

    It always meet the question of DSP chips and analog/digital converter interface in the embedded data transmission system in order to improve the speed and the precision of signal's acquisition and sampling and enhance the system's reliability, the principle and the method of designing hardware and software are introduced in the multi-channel buffered serial port (McBSP) receiver based on DSP.The fixed-point DSP TMS320VC5502 and the high-speed lO-bit successive-approximation ananlog-to-digital converter (ADC) TLV1572 produced by TI company are interfaced glulessly,analog signal sampled by TLV1572 is converted to digital signal through the A/D and is received by McBSP, the real-time data can be transferred directly without convertion. The system with general purpose is designed with high reliability and can be implemented easily.%在嵌入式数据传输系统中经常会遇到DSP芯片与模/数转换器接口的问题,为提高信号的采样、传输速度与精度,增强系统可靠性,给出了基于DSP芯片的多通道缓冲串口(McBSP)在数据传输中作为接收器的原理、硬件与软件设计方法.选用TI公司的C5000系列定点DSP TMS320VC5502芯片与TI公司的10位高速串行逐次逼进型转换器模/数转换芯片TLV1572进行无缝连接,通过TLV1572对模拟数据进行采样,后经A/D转换为数字信号,DSP的McBSP串口进行接收,实现了不经任何转换的实时数据传输.该系统设计方案电路简单,可靠性好,易于实现,具有一定的通用性.

  13. Using the IODP Expedition 312 Vertical Seismic Profile to Investigate Sub-basement Reflections in Multi-Channel Profiles

    Science.gov (United States)

    Nag, S.; Swift, S. A.; Stephen, R. A.

    2008-05-01

    The Ocean Drilling Program (ODP) initiated drilling at Site 1256D in the Guatemala Basin, about 1000km off the East Pacific Rise to penetrate plutonic rocks, anticipated to be relatively shallow in this region formed at an ultra- fast spreading rate. IODP Expedition E312 successfully drilled into gabbros at ~ 1150m in basement. Multi- channel seismic traces, although not processed for the purpose, show weak laterally-coherent sub-basement reflections at borehole depths (Hallenborg et. al., Journal of Geophysical Research, Vol 108 No. B11, 2532, 2003). Synthetic reflectivity seismograms were computed using a Ricker wavelet and impedance profiles from borehole sonic logs. They strongly suggest the presence of significant sub-basement amplitude peaks - although attenuation has not been modeled. Zero-offset vertical seismic profiles were processed to investigate the authenticity of these reflections and interpret the geological features that caused them. A dual scheme of the median filtering and F-K dip filtering was used. Down-going energy is clearly identified but negligible up-going energy is visible over random noise. The absence of geophones above the basement prevents comparison of basement reflections with sub-basement ones, so that a critical energy level above the noise could be established to identify up-going energy. The negative results are consistent with the topography of geological horizons on horizontal scales less than the Fresnel Zone (~ 300m). This expedition is the first penetration through volcanic extrusives and dikes into plutonic basement. In such a setting, sub-basement reflections, if present, would have been accurately measured. Absence of such clear and comprehensible observations in this area strongly suggests that lava flows and igneous contacts in upper ocean crust have significant topography on lateral scales < 300 m due to igneous and tectonic processes.

  14. Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors.

    Science.gov (United States)

    Mendez, Lucas C; Paudel, Moti; Wronski, Matt; Ravi, Ananth; Barbera, Lisa; Leung, Eric

    2017-05-18

    To evaluate the dosimetric performance of multi-channel vaginal cylinder (MCVC) against interstitial brachytherapy (ISBT) for the treatment of vaginal tumors. Vaginal tumors with extension of > 0.5 cm and ≤ 2 cm from the lateral vaginal wall and/or ≤ 1 cm in height above the vaginal vault were retrospectively selected from a ISBT registry trial database. The selected patients were treated with ISBT and targets included the intermediate (IRCTV) or high-risk (HRCTV) clinical target volumes. For technique comparison, a 35 mm MCVC was registered with the interstitial intra-vaginal cylinder. Bladder and rectum contours were transferred from the ISBT to the MCVC-BT plans. Vaginal mucosa was achieved by 3 mm uniform expansion from cylinder surface. Both the ISBT and MCVC-BT plans were optimized using the Inverse Planning Simulated Annealing optimization algorithm. After normalizing target D90 to 700 cGy, dose to organs at risk were measured and compared between ISBT and MCVC plans. Six interstitial patient plans met the inclusion criteria for this study. Four patients had vaginal primaries and two recurrent cancers in the vagina. Lower doses to bladder and rectum were seen with ISBT plans. In half of the MCVC plans, the rectal dose met the recommended constraints. For plans in which the rectal constraint was not met, the target volumes were abutting the rectum and had a cranial-caudal length ≥ 5 cm. Dose to vaginal mucosa was lower in ISBT plans directed to the HRCTVs, although no difference was seen in circumferential IRCTVs. Overall, ISBT results in decreased dose to OARs as compared to MCVC. However, MCVC BT results in acceptable doses to OARs with possible improvement in vaginal doses for circumferential targets. Careful consideration to tumor geometry and location may help guide optimal techniques in vaginal tumor brachytherapy.

  15. PAD-MAC: primary user activity-aware distributed MAC for multi-channel cognitive radio networks.

    Science.gov (United States)

    Ali, Amjad; Piran, Md Jalil; Kim, Hansoo; Yun, Jihyeok; Suh, Doug Young

    2015-03-30

    Cognitive radio (CR) has emerged as a promising technology to solve problems related to spectrum scarcity and provides a ubiquitous wireless access environment. CR-enabled secondary users (SUs) exploit spectrum white spaces opportunistically and immediately vacate the acquired licensed channels as primary users (PUs) arrive. Accessing the licensed channels without the prior knowledge of PU traffic patterns causes severe throughput degradation due to excessive channel switching and PU-to-SU collisions. Therefore, it is significantly important to design a PU activity-aware medium access control (MAC) protocol for cognitive radio networks (CRNs). In this paper, we first propose a licensed channel usage pattern identification scheme, based on a two-state Markov model, and then estimate the future idle slots using previous observations of the channels. Furthermore, based on these past observations, we compute the rank of each available licensed channel that gives SU transmission success assessment during the estimated idle slot. Secondly, we propose a PU activity-aware distributed MAC (PAD-MAC) protocol for heterogeneous multi-channel CRNs that selects the best channel for each SU to enhance its throughput. PAD-MAC controls SU activities by allowing them to exploit the licensed channels only for the duration of estimated idle slots and enables predictive and fast channel switching. To evaluate the performance of the proposed PAD-MAC, we compare it with the distributed QoS-aware MAC (QC-MAC) and listen-before-talk MAC schemes. Extensive numerical results show the significant improvements of the PAD-MAC in terms of the SU throughput, SU channel switching rate and PU-to-SU collision rate.

  16. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    Directory of Open Access Journals (Sweden)

    Samuel M Shin

    2015-09-01

    Full Text Available Introduction: Evaluate use of novel multi-channel applicator (MC CapriTM to improve vaginal disease coverage achievable by single-channel applicator (SC and comparable to Syed plan simulation. Material and Methods: 28 plans were evaluated from 4 patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by 3 weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth to 1500 cGy/3 fractions with a simultaneous integrated boost totaling 2100 cGy/3 fractions to tumor. Modeling of SC and Syed plans was performed using MC scans for each patient. Dosimetry for MC and SC plans was evaluated for PTV700 cGy coverage, maximum dose to 2cm3 to bladder, rectum as well as mucosal surface points. Dosimetry for Syed plans was calculated for PTV700 cGy coverage. Patients were followed for treatment response and toxicity.Results: Dosimetric analysis between MC and SC plans demonstrated increased tumor coverage (PTV700 cGy, with decreased rectal, bladder, and contralateral vaginal mucosa dose in favor of MC. These differences were significant (p<0.05. Comparison of MC and Syed plans demonstrated increased tumor coverage in favor of Syed plans which were not significant (p=0.71. Patients treated with MC had no cancer recurrence or ≥ grade 3 toxicity.Conclusion: Use of MC was efficacious and safe, providing superior coverage of tumor volumes ≤1cm depth compared to SC and comparable to Syed implant. MC avoids excess dose to surrounding organs compared to SC, and potentially less morbidity than Syed implants. For tumors extending ≤1cm depth, use of MC represents an alternative to an interstitial implant.

  17. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    Science.gov (United States)

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  18. Density of states of Frenkel excitons in weakly disordered systems

    Science.gov (United States)

    Boukahil, Abdelkrim; Zettili, Nouredine

    2002-04-01

    We present the calculation of the density of states of Frenkel excitons in weakly disordered one , two , and three-dimensional systems. A random distribution of transition frequencies with variance s2 characterizes the disorder. The Coherent Potential Approximation (CPA) calculations show that the density of states (DOS) is very sensitive to any variations in the disorder parameter s. Our calculations are in good agreement with previous work based on the Monte Carlo simulation. One of us (AB) acknowldges the support of the University of Wisconsin--Whitewater for this work through a university research grant.

  19. Congenital and acquired mitochondrial disorders of the central nervous system

    OpenAIRE

    V. V. Nikitina; A. N. Pravdina

    2014-01-01

    Clinical presentations of disorders of the nervous system manifest in young and middle-aged patients with congenital and acquired mitochondrial dysfunctions and cognitive disorders manifest in patients with mitochondrial diseases more often. Nowadays the effective methods of initial diagnosing of these conditions are neurological and neuropsychological examination of patients, using of biochemical markers of mitochondrial diseases: the indices of lactate, total homocysteine in plasma and liqu...

  20. Central nervous system inflammatory demyelinating disorders of childhood

    OpenAIRE

    Kamate Mahesh; Chetal Vivek; Tonape Venkatesh; Mahantshetti Niranjana; Hattiholi Virupaxi

    2010-01-01

    Background and Objectives: Childhood Central Nervous System (CNS) inflammatory demyelinating disorders (CIDD) are being diagnosed more commonly now. There is ambiguity in the use of different terms in relation to CIDD. Recently, consensus definitions have been proposed so that there is uniformity in studies across the world. The prevalence of these disorders and the spectrum varies from place to place. This study was undertaken to study the clinico-radiological profile and outcome of children...