WorldWideScience

Sample records for disease ct evaluation

  1. Evaluation of diseases of the aorta with ultrafast CT

    International Nuclear Information System (INIS)

    Eldredge, W.J.; Flicker, S.; Altin, R.S.; Naidech, H.J.

    1987-01-01

    Ultrafast CT offers several advantages over standard CT for imaging of various congenital and acquired diseases of the aorta. Scan acquisition rates of 50 msec permit evaluation of the entire aorta following a single peripheral intravenous injection of iodinated contrast medium. Pathologic aortic flow patterns may also be defined using an ECG triggered ''flow'' mode, adding another dimension to CT evaluation of the aorta. The papers shows examples of a variety of aortic diseases, including coarctation, Marfan syndrome, atherosclerotic aneurysm, dissection, and postoperative abnormalities. The advantages of the modality are stressed

  2. CT evaluation of severe renal inflammatory disease in children

    International Nuclear Information System (INIS)

    Montgomery, P.; Kuhn, J.P.; Afshani, E.

    1987-01-01

    We have performed CT scans on 15 children and 2 young adults with severe renal inflammatory disease. Most children with urinary tract infections do not require such evaluation. We have, however, found CT helpful in defining the nature of renal abnormality and in defining the extent of disease in selected patients who either presented as diagnostic dilemmas or who did not respond initially to proper medical treatment. We therefore use CT scanning as our initial examination in such problem patients. (orig.)

  3. The clinical evaluation of CT and radionuclide examination in renal diseases

    International Nuclear Information System (INIS)

    Kutani, Wataru; Ishida, Hirofumi; Shirakawa, Shigetoshi; Shintaku, Takao; Funaki, Ryo

    1980-01-01

    One hundred and twelve cases of renal diseases were studied by computed tomography (CT) using EMI 5005/12. Of them, 60 were examined by both CT and renal scintigraphy, and comparatively evaluated. The CT units were checked before and after the contrast enhancement. Renal scintigrams were obtained by gamma cameras (PHO/GAMMA HP 6406, PHO/GAMMA LFOV) using 99 M Tc-DMSA. CT was especially useful in diagnosing the renal cysts and the hydronephrosis. Cysts in other organs (liver, spleen and pancreas) were simultaneously ascertained in polycystic diseases. CT was not helpful in diagnosing nephritis and diabetic nephropathy. Floating kidney and horse-shoe kidney were difficult to diagnose with CT. The renal scintigram was the reflection of the renal function, and was relatively more useful than CT in diagnosing horse-shoe kidney, floating kidney and nephritis, while it was not useful for non-functioning kidneys. (author)

  4. Evaluation of diffuse thyroid diseases and thyroid nodules by CT

    International Nuclear Information System (INIS)

    Okamoto, Kyoko; Imanishi, Yoshimasa; Nakaji, Shunsuke; Shinagawa, Toshihito

    2007-01-01

    Imanishi et al. have previously reported that the changes in CT values reveal not only the change in iodine concentration in thyroid follicles, but also represent secondary changes in follicular content and follicular cells and/or interstitial structures. Thus, we performed thyroid CT without contrast material in 138 controls, 417 cases with diffuse thyroid diseases, and 279 cases with thyroid nodules, and evaluated the CT images based on the relation between the change in CT values and pathological changes. In 89% of the controls and 43% of patients with diffuse thyroid diseases, the thyroid CT revealed diffuse high density. In contrast, the 94% of thyroids that demonstrated diffuse low density were from patients with diffuse thyroid diseases. Eighty-four percent of malignant nodules and 64% of benign nodules had inhomogeneous densities, and only 26% of benign thyroid nodules had homogeneous density. However, 71% of nodules that showed high and low densities with regular and clear borders, and 82% of nodules that showed papillary proliferation in a cyst pattern were benign. Although only 58% of nodules with calcification were malignant, 66% of nodules with calcification in the central portion, and 86% of nodules with calcification of a disseminated and convergent pattern in distribution were malignant. Sixty-two percent of thyroids that surrounded nodules had chronic thyroiditis, hypoplasia and/or adenomatous goiter. Thus, unclear borders between a nodule and the surrounding thyroid tissue did not increase the possibility of malignancy. However, the unclear and/or lobulated border between a nodule and extra thyroid tissue increased the possibility of malignancy. We concluded that thyroid CT without contrast material is useful for the diagnosis of thyroid diseases. (author)

  5. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  6. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  7. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon

    1988-01-01

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult cases.

  8. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  9. Role of CT in patients with prostatic disease

    International Nuclear Information System (INIS)

    Yoshizako, Takeshi; Sugimura, Kazuro; Kaji, Yasushi; Moriyama, Masahiro; Ishida, Tetsuya

    1994-01-01

    The purpose of this study was to evaluate the role of CT in patients with and without prostatic disease. CT and MR findings were reviewed in 25 patients without known prostatic disease, 11 patients with benign prostatic hyperplasia and 11 patients with prostatic cancer. Differential attenuation allowed for distinction of the peripheral zone and inner gland of the prostate by CT in 72% of normal patients. The distinction rate of prostatic zonal anatomy by CT decreased to 30% in the diseased group. When zonal anatomy of the prostate is not visualized on pelvic enhanced CT, the presence of prostatic disease might be considered. (author)

  10. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    Science.gov (United States)

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. CT diagnosis in diseases of the breast

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the CT signs of breast diseases, and discuss the value of CT in the diagnosis of breast cancer and the axillary lymph node (LN) metastases. Materials and methods: Fifty three cases were reported, including breast cancer 30 cases and benign diseases 23 cases. CT were performed in all patients, 44 also had mammography examination. Results: (1) The CT appearance of breast cancer: round or irregular mass, spiculate border, duct retraction, involved Cooper's ligament, deformed adipose space etc. Benign hyperplasia: Irregular mass and symmetrical thickening of breast glands. Cystic hyperplasia: typically multiple, round, liquid-density mass. (2) CT was comparable to mammography in terms of differential diagnosis, however with breast mass located near the axilla or for evaluation of the thoracic wall. CT was superior to mammography. CT was also helpful in detecting LN metastases. Conclusion: CT is valuable in detecting and differentiating breast diseases as well as in the diagnosis of LN metastases

  12. Evaluation of pleural disease using MR and CT: With special reference to malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Knuuttila, A.; Kivisaari, L.; Kivisaari, A.; Palomaeki, M.; Tervahartiala, P.; Mattson, K.

    2001-01-01

    Purpose: To evaluate MR imaging and CT in differentiating malignant pleural mesothelioma from other malignancies or benign pleural disease. Material and Methods: Thirty-four patients (18 pleural mesothelioma, 9 other malignancies, 7 benign pleural diseases) were examined using enhanced CT and MR. Two radiologists reviewed the CT and two others the MR images. Comparisons were made between the diagnostic groups and the imaging methods. Results: The abnormalities commonly found in malignant disease, but significantly less frequently in benign pleural disease, were focal thickening and enhancement of inter lobar fissures. In mesothelioma, enhancement of inter lobar fissures, tumour invasion of the diaphragm, mediastinal soft tissue or chest wall, were significantly more often observed than in other malignancies and MR was the most sensitive method. In other malignancies, invasion of bony structures was a more common finding and was also better shown by MR. The contrast-enhanced T1 fat-suppressed (CET1fs) sequence detected these features better than other MR sequences. Conclusion: MR, especially the CET1fs sequence in three planes, gave more information than enhanced CT. Focal thickening and enhancement of inter lobar fissures were early abnormalities indicating malignant pleural disease. MR could be clinically useful for differentiating mesothelioma from other pleural diseases

  13. Evaluation of pleural disease using MR and CT: With special reference to malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Knuuttila, A. [Helsinki Univ. Central Hospital (Finland). Dept. of Medicine; Kivisaari, L.; Kivisaari, A.; Palomaeki, M.; Tervahartiala, P. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Mattson, K. [Helsinki Univ. Central Hospital (Finland). Dept. of Medicine

    2001-09-01

    Purpose: To evaluate MR imaging and CT in differentiating malignant pleural mesothelioma from other malignancies or benign pleural disease. Material and Methods: Thirty-four patients (18 pleural mesothelioma, 9 other malignancies, 7 benign pleural diseases) were examined using enhanced CT and MR. Two radiologists reviewed the CT and two others the MR images. Comparisons were made between the diagnostic groups and the imaging methods. Results: The abnormalities commonly found in malignant disease, but significantly less frequently in benign pleural disease, were focal thickening and enhancement of inter lobar fissures. In mesothelioma, enhancement of inter lobar fissures, tumour invasion of the diaphragm, mediastinal soft tissue or chest wall, were significantly more often observed than in other malignancies and MR was the most sensitive method. In other malignancies, invasion of bony structures was a more common finding and was also better shown by MR. The contrast-enhanced T1 fat-suppressed (CET1fs) sequence detected these features better than other MR sequences. Conclusion: MR, especially the CET1fs sequence in three planes, gave more information than enhanced CT. Focal thickening and enhancement of inter lobar fissures were early abnormalities indicating malignant pleural disease. MR could be clinically useful for differentiating mesothelioma from other pleural diseases.

  14. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  15. Cardiac PET/CT for the diagnosis and prognostic evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Geronazzo, R.J.; Romero, R.L.; Campisi, R.

    2014-01-01

    Coronary artery disease is considered by de World Health Organization (WHO) to be pandemic. Eighty percent of the deaths occurs secondary to coronary artery disease, stroke and diabetes, thus they can be prevented. All of them are related to the same risk factors. Ischemic heart disease is the mayor cause of death in Argentina in the elderly population. Primary prevention strategies are essential in the health system. Hence, image complementary methods are very important to accomplish risk stratification, secondary prevention and pre-surgical evaluation. Nuclear cardiology has occupied this place through myocardial perfusion studies with radiopharmaceuticals, using SPECT (Single photon emission computed tomography) that have improved the level of sensitivity and specificity with ECG gated. Furthermore, positron emission tomography (PET) can evaluate relative myocardial perfusion, quantify absolute myocardial blood flow and coronary flow reserve. With its capacity to quantify rest-peak stress left ventricular systolic function we can underscore for example “balance ischemia”. By using hybrid PET/CT, also we can get information of coronary artery calcium scoring and coronary angiography. Currently, with the available softwares, we can acquire images in List mode. It means, from a single acquisition, it allows multiple image reconstructions, along with the associated electrocardiographic phase. PET/CT uses radiopharmaceuticals with short physical half life, and in conjunction with the possibility of acquiring in 3D mode, the perfusion studies can be done in a short time and offers lower radiation exposure to the patient. The new softwares for routine correction of misalignments between transmission and emission images have helped to reduce the frequency of artifacts and improve diagnostic accuracy. Hybrid PET/CT technology allows functional evaluation of myocardial perfusion combined with anatomic characterization of the epicardial coronary arteries, thereby

  16. Usefulness of {sup 18}F FDG PET/CT in evaluating disease activity at different times in a patient with chronic periaortitis

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio; Stefanelli, Antonella; Mattoli, Maria Vittoria; Leccisotti, Lucia; Muoio, Barbara [Catholic Univ. of the Sacred Heart, Rome (Italy); Bertagna, Francesco [Univ. of Brescia, Brescia (Italy)

    2012-03-15

    We report the case of a 53 year old man with a chronic periaortitis (CP) in whom Fluorine 18 Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has been useful in assessing the disease extent at diagnosis, in evaluating the treatment response, in diagnosing the relapse, and in monitoring the disease activity during follow up. This case highlights the usefulness of FDG PET/CT at different times in patients with CP. CP is a rare inflammatory disorder that affects the abdominal aorta and the retroperitoneum. Imaging procedures are essential to diagnose and monitor the disease course. Ultrasonography may be used as first line screening test, and is particularly useful to monitor patients with hydronephrosis and aortic aneurysms. However, CT or magnetic resonance imaging (MRI) of the abdomen are currently considered the investigations of choice to diagnose CP. In active CP, the periaortic mass usually enhances on CT and MRI. Both these methods can be used to monitor the disease course of CP and to evaluate response to treatment. A note of caution: signs of vasculitis seen on MRI and CT may persist for some time, despite achievement of clinical remission. A further limitation of abdominal CT and MRI is that neither technique can detect vasculitis in vessels other than the abdominal aorta, which has been described in 43% of patients with CP. FDG PET/CT has been proposed as useful tool in inflammatory diseases, such as aortitis, because metabolic changes assessed by FDG PET/CT usually precede morphological changes assessed by conventional imaging methods. Our case highlights the usefulness of FDG PET/CT at different times in patients with CP. This method may be useful in assessing disease activity and extent at diagnosis, in evaluating the treatment response, in diagnosing the relapse, and in monitoring the disease during follow up.

  17. CT evaluation of optic nerve compression in thyroid eye disease

    International Nuclear Information System (INIS)

    Barrett, L.; Giatt, H.J.; Burde, R.M.; Gado, M.

    1986-01-01

    In thyroid eye disease, visual loss due to optic nerve compression by enlarged muscles near the orbital apex requires prompt surgical decompression and must be differentiated from visual loss due to other mechanisms. Seventy-two high-resolution orbital CT scans of patients with thyroid eye disease were analyzed. From a coronal reconstruction, an easily measured ''apical index'' was determined. Average apical indices for orbits without optic neuropathy (41.0%) and with optic neuropathy (70.2%) were significantly different (P < .001). With the aid of the apical index, CT findings can be used to predict which patients with thyroid eye disease have optic nerve compression

  18. PET/CT and vascular disease: Current concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Souza Leao Lima, Ronaldo de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Souza Machado Neto, Luiz de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Kayat Bittencourt, Leonardo, E-mail: lkayat@terra.com.br [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Cortes Domingues, Romeu [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Fonseca, Lea Mirian Barbosa da [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil)

    2011-10-15

    Since its introduction in 2001, positron emission tomography associated to computed tomography (PET/CT) has been established as a standard tool in cancer evaluation. Being a multimodality imaging method, it combines in a single session the sensitivity granted by PET for detection of molecular targets within the picomolar range, with an underlying submilimetric resolution inherent to CT, that can precisely localize the PET findings. In this last decade, there have been new insights regarding the pathophysiology of atherosclerosis, particularly about plaque rupture and vascular remodeling. This has increased the interest for research on PET/CT in vascular diseases as a potential new diagnostic tool, since some PET molecular targets could identify diseases before the manifestation of gross anatomic features. In this review, we will describe the current applications of PET/CT in vascular diseases, emphasizing its usefulness in the settings of vasculitis, aneurysms, vascular graft infection, aortic dissection, and atherosclerosis/plaque vulnerability. Although not being properly peripheral vascular conditions, ischemic cardiovascular disease and cerebrovascular disease will be briefly addressed as well, due to their widespread prevalence and importance.

  19. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  20. Tuberculous Addison's disease: Morphological and quantitative evaluation with multidetector-row CT

    International Nuclear Information System (INIS)

    Ma Ensen; Yang Zhigang; Li Yuan; Guo Yingkun; Deng Yuping; Zhang Xiaochun

    2007-01-01

    Objective: To determine the characteristics of tuberculous Addison's disease on the axial and multiplanar reformatted (MPR) images of the multidetector-row computed tomography (MDCT). Materials and methods: The unenhanced and contrast-enhanced MDCT features in 19 patients with tuberculous Addison's disease were retrospectively assessed for the location, contour, size, calcification, attenuation, and enhancement patterns. The correlation between the duration of Addison's disease and the percentage of calcification presence was evaluated. Results: The adrenal glands were infected bilaterally in all of the 19 cases (100%, 38 glands). Enlargement of the glands appeared in 18 cases (94.7%, 36 glands) and the remaining one case (5.3%, two glands) showed atrophy bilaterally. Of the 36 enlarged adrenals, 13 (36.1%) had preserved contours, and the other 23 (63.9%) were mass-like. The size of the adrenals ranged from 0.6 to 4.8cm (mean 1.92+/-0.96cm). Calcification was revealed in 16 adrenals (16/38, 42.1%), increasing in incidence with disease progression. Fourteen of the 36 (38.9%) enlarged adrenals showed peripheral enhancement while the remaining 22 (61.1%) demonstrated heterogeneous enhancement. The ΔCT value, the attenuation measurement of mass-like lesions, was less in the central area (7+/-4HU) than that in the peripheral area (32+/-14HU) (P<0.01) between the unenhanced and contrast-enhanced scan. Conclusion: MDCT can reveal the characteristic morphology and CT attenuation in the tuberculous Addison's disease. Combined with its clinical presentations and biochemical findings, we can diagnose and stage adrenal tuberculosis with high specificity and accuracy on MDCT

  1. Guideline for appropriate use of cardiac CT in heart disease

    International Nuclear Information System (INIS)

    Kim, Young Jin; Hong, Yoo Jin; Yong, Hwan Seok; Kim, Sung Mok; Kim, Jeong A; Yang, Dong Hyun

    2014-01-01

    Heart disease is one of the leading causes of deaths in Korea, along with malignant neoplasms and cerebrovascular diseases. The proper diagnosis and management for patients with suspected heart diseases should be warranted for the public health care. Advances in CT technology have allowed detailed images of the heart to be obtained, which enable evaluations not only of the coronary arteries but also of other cardiac structures. Currently, the latest multi-detector CT machines are widespread around Korea. The appropriate use of cardiac CT may lead to improvements of the physicians' medical performances and to reduce medical costs which eventually contribute to promotions of public health. However, until now, there has been no guidelines regarding the appropriate use of cardiac CT in Korea. We intend to provide guidelines for the appropriate use of cardiac CT in heart diseases based on scientific data. The purpose of this guideline is to assist the clinicians and other health professionals when using cardiac CT for diagnosis and treatments of heart diseases.

  2. Evaluation of using 99Tcm-MDP SPECT/CT for differentiating malignancy from benignancy in femoral diseases

    International Nuclear Information System (INIS)

    Ou Xiaohong; Huang Rui; Su Minggang; Zhou Li'na; Fan Qiuping

    2010-01-01

    Objective: To evaluate the value of SPECT/CT in assessment of femoral foci of abnormal bone metabolism classified as intermediated on bone scanning using 99Tcm-methylene diphosphonate (MDP). Methods: There were 94 patients with solitary femoral abnormal uptake in bone scanning included. SPECT was accompanied by inline CT over the femoral region. All of the images were blindly interpreted independently by two experienced board-certified radiologists. The reference standard was follow-up over half a year of MRI, CT, SPECT, or pathology. Diagnosis which consist with reference were counted as accurate. Diagnosis which either not consist with reference or undetermined were counted as false. Results: Of the 94 patients, 78 patients (male 42 , female 36, mean age 62 yrs) have the definite diagnosis of their femoral foci. 19 were proved to be metastasis and the other 59 were benign diseases. The diagnostic accuracy by bone SPECT, bone CT and fusion imaging were 58.9%, 87.2%, 96.2% respectively. Conclusions: Most of the solitary femoral foci caused by benign diseases. SPECT/CT using 99 Tc m -MDP has additional valuable in differentiating malignancy from benignancy in femoral foci . (authors)

  3. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  4. CT findings of diffuse pleural diseases: differentiation of malignant disease from tuberculosis

    International Nuclear Information System (INIS)

    Roh, In Gye; Kook, Shin Ho; Lee, Young Rae; Chin, Seung Bum; Park, Yoon Ok; Park, Hae Won

    1997-01-01

    To evaluate whether or not previously known CT criteria for differentiating malignant and benign pleural diseases are useful in the differentiation of diffuse malignant pleural diseases and tuberculosis. We retrospectively analyzed CT scans of 42 patients comprising 20 cases of malignant pleural diseases and 22 cases of tuberculous pleural diseases, according to previously known CT criteria for differentiating malignant and benign pleural diseases. The most common shape of pleural effusion was crescentic in malignant pleural diseases and loculated in tuberculosis. The aggressive nature of pleural effusion, pleural rind, and pleura thickening was 1.5 times more frequently observed in malignant pleural diseases than in tuberculosis. Smooth thickening or smooth nodular pleural thickening and extrapleural deposition of fat were 1.5 times more frequently found in tuberculous than in malignant pleural diseases. Interruption of pleural thickening was found twice as frequently in malignant pleural diseases as in tuberculosis. Decreased lung volume was found twice as frequently in tuberculous as in malignant pleural diseases. Anatomical mediastinal pleural involvement was three times, and irregular nodular pleural thickening nine times more frequent in malignant pleural diseases than in tuberculosis. The sensitivity and specificity of CT findings above 70%, and thus suggesting malignant pleural diseases, were as follows : 1) aggressive nature of pleural fluid collection extending to the azygoesophageal recess or tongue of the lung (51.5%, 75%); 2) involvement of anatomical mediastinal pleura (69.2%, 73.7%); 3) irregular nodular pleural thickening (87.5%, 69%). Although there in overlap between previously known CT criteria for the differentiation of benign and malignant pleural diseases, the aggressive nature of pleural fluid collection extending to the azygoesophageal recess or tongue of the lung, the involvement of anatomical mediastinal pleura and irregular nodular

  5. Comparison of CT and MRI in the evaluation of therapeutic responce in thoracic Hodgkin disease

    International Nuclear Information System (INIS)

    Elkowitz, S.S.; Leonidas, J.C.; Lopez, M.; Cherick, I.; Schiff, R.G.; Karayalcin, G.; Lanzkowsky, P.

    1993-01-01

    Current imaging modalities are accurate in establishing the diagnosis and extent of thoracic Hodgkin disease. After treatment, however, it is extremely difficult to differentiate potential residual active neoplastic disease from scar tissue, or identify early recurrence. We evaluated the contribution of MRI in the assessment of the response to treatment of thoracic Hodgkin disease in the assumption that scar formation would be characterized by low signal intensity in all pulse sequences, whereas active tumor should maintain a degree of high signal intensity on T2-weighted images. In 47 occasions (23 patients) both CT and MRI were able to identify correctly active disease, but had low specificity in confirming remission because of residual tissues masses. High signal intensity on T2-weighted MR images often persisted despite remission, probably because of edema, necrosis, granulation or other factors. MRI was somewhat more specific than CT and may be quite valuable to confirm remission in patients with residual masses that no longer appear hyperintense on T 2 after treatment. (orig.)

  6. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  7. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  8. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  9. Role of CT in Congenital Heart Disease.

    Science.gov (United States)

    Rajiah, Prabhakar; Saboo, Sachin S; Abbara, Suhny

    2017-01-01

    Congenital heart diseases (CHD) are being increasingly encountered in cardiac imaging due to improved outcomes from surgical and interventional techniques. Imaging plays an important role in the evaluation of CHD, both prior to and after surgeries and interventions. Computed tomography (CT) has several advantages in the evaluation of these disorders, particularly its high spatial resolution, multi-planar reconstruction capabilities at sub-millimeter isotropic resolution, good temporal resolution, wide field of view, and rapid turnaround time, which minimizes the need for sedation and anesthesia in young children or children with disabilities. With modern scanners, images can be acquired as fast as within one heartbeat. Although there is a risk of ionizing radiation, the radiation dose can be minimized by using several dose reduction strategies. There is a risk of contrast nephrotoxicity in patients with renal dysfunction. In this article, we will review the role of CT in the evaluation of several congenital heart diseases, both in children and adults.

  10. Albendazole treatment of cerebral hydatid disease: evaluation of results with CT and MRI

    International Nuclear Information System (INIS)

    Kalaitzoglou, I.; Drevelengas, A.; Petridis, A.; Palladas, P.

    1998-01-01

    We report a case of cerebral hydatid disease demonstrated by CT and MRI, treated with albendazole. Follow-up showed complete dissapearance of the cysts with residual focal calcification on CT and presumed gliosis on MRI. (orig.)

  11. Cystic thymic diseases: CT manifestations

    International Nuclear Information System (INIS)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok

    1995-01-01

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component

  12. Albendazole treatment of cerebral hydatid disease: evaluation of results with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kalaitzoglou, I.; Drevelengas, A.; Petridis, A.; Palladas, P. [Department of Radiology, ``G. Papanikolaou`` General Hospital, Thessaloniki (Greece)

    1998-01-01

    We report a case of cerebral hydatid disease demonstrated by CT and MRI, treated with albendazole. Follow-up showed complete dissapearance of the cysts with residual focal calcification on CT and presumed gliosis on MRI. (orig.) With 3 figs., 17 refs.

  13. The use of thin-section high-resolution CT in pediatric pulmonary disease

    International Nuclear Information System (INIS)

    Hay, T.C.; Horgan, J.G.; Rumack, C.M.

    1989-01-01

    High-resolution thin-section CT of the chest was used successfully to characterize the extent of pulmonary disease. This paper reports on a study in which ten children with chronic lung disorders (including cystic fibrosis, reactive airway disease, and idiopathic disease) were evaluated to test the accuracy of the posteroanterior and lateral chest CT, with both thick (1 cm) and thin (1-3 mm) sections. Unsuspected bronchiectasis was established n two patients with reactive airway disease, and the extent of bronchiectasis in other patients was best defined on thin-section CT. Technique was crucial for an accurate study, and magnification views of each lung were useful. Thin-section CT of the chest was helpful in defining and localizing the extent of these pulmonary disorders

  14. Cystic thymic diseases: CT manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-09-15

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component.

  15. Detectability of T Measurable diseases in advanced gastric cancer in FDG PET CT

    International Nuclear Information System (INIS)

    Oh, Sun Young; Cheon, Gi Jeong; Kim, Young Chul; Jeong, Eugene; Kim, Seung Eun; Choe, Jae Gol

    2012-01-01

    Usefulness of FDG PET CT in monitoring response in locally advanced gastric cancer has been reported. The purpose of this study was to evaluate the related factors to detect measurable diseases in advanced gastric cancer on FDG PET CT. We retrospectively reviewed 38 patients diagnosed as having advanced gastric cancer. We defined the measurable diseases when there was visualized tumor of which maximum standardized uptake value(SUVmax) was higher than 1.35*SUVmax of liver + 2*SD of liver SUV. We evaluated what kinds of factors from the clinicopathologic features were related to identifying measurable diseases. Of 38 patients with advanced gastric cancer, 18 (50%) had measurable tumors on FDG PET CT. Measurable tumors were significantly more frequent in well or moderately differentiated adenocarcinoma (70.5% vs 35.3%, p<0.05), in the tumors located at antrum or angle (66.7% vs 29.4%, p<0.05) and in the elderly group (age of 55 years old or more, 72.0% vs 8.3%, p<0.001) than the others, respectively. By multivariate analysis, age at diagnosis was the only independent predictor for the measurable disease on FDG PET CT. We found that age at diagnosis, as well as histologic types and location of tumors, were the affecting factors to detect measurable disease on FDG PET CT in patients with advanced gastric cancer. Our study suggests that elderly patients of age of 55 years old or more can frequently have T measurable disease on FDG PET CT in advanced gastric cancer and FDG PET CT will be helpful to monitor measurable disease

  16. Multidetector CT and MRI in diseases of the GI tract

    International Nuclear Information System (INIS)

    Bruel, J.M.; Gallix, B.

    2003-01-01

    With the introduction of spiral scanning then multidetector technologies, the accuracy for diagnosing digestive tract diseases with CT has been highly improved, and CT is used more and more in the evaluation of patients with suspected gastrointestinal disorders. CT is able to demonstrate both the intramural and the extra-mural components of the disease, and has a major role in the preoperative staging and the follow-up Improvements of CT protocols, such as CT-enteroclysis, or multiplanar 2D and 3D post-processing, including now techniques for 'virtual endoscopy', lead to discuss new indications in which CT could now compete with conventional X-rays series and video-endoscopy. This precise study of the digestive wall, the peri-digestive fat, the digestive tract blood supply, may be performed by MRI, under the condition of access to high level machines and standardized protocols. MR-enteroclysis and MR-virtual colonoscopy could be performed with much lower risk for the patient, in terms of radiation dose or contrast adverse effects. Endo-luminal coils should give to MR an ultra-high resolution for analysing the different layers of the gastrointestinal wall. Learning objectives: to review how to perform CT and MRI protocols for digestive tract imaging, to recognize the CT arid MR patterns of the main digestive tract diseases, to discuss the value, limits and role of CT and MR in digestive tract diseases, to discuss the potential role of CT and MR new technological developments for digestive tract imaging in the upcoming future Conclusion: CT is nowadays a modality of choice for digestive imaging. Improvements in technologies and indications, the necessary discussion of the risks and benefits for the patient should let the radiologists consider MRI in gastrointestinal disorders as an important part of the routine activity in clinical MRI. (authors)

  17. Addison's disease due to adrenal tuberculosis: Contrast-enhanced CT features and clinical duration correlation

    International Nuclear Information System (INIS)

    Guo Yingkun; Yang Zhigang; Li Yuan; Ma Ensen; Deng Yuping; Min Pengqiu; Yin Longlin; Hu Jian; Zhang Xiaochun; Chen Tianwu

    2007-01-01

    Purpose: To describe CT morphology of untreated adrenal tuberculosis during the different stages of the natural history of the disease and to evaluate the diagnostic implications of CT features. Materials and methods: We retrospectively evaluated CT features in 42 patients with documented adrenal tuberculosis for the location, size, morphology, and enhancement patterns shown on CT images. The clinical duration were correlated with the CT features. Results: Of the 42 patients with untreated adrenal tuberculosis, bilaterally enlarged adrenal glands were revealed in 38 cases (91%), unilaterally enlarged in 3 cases (7%), and normal size in 1 case (2%). Of the 41 cases (98%) with enlargement, mass-like enlargement was seen in 20 cases (49%) and enlargement with preserved contours in 21 cases (51%). Peripheral rim enhancement presented in 22 cases (52%) on contrast-enhanced CT. Non-enhanced CT scan revealed calcification in 21 cases (50%). As the duration of Addison's disease increased, the presence of calcification and contour preservation increased concomitantly (p < 0.001), whereas peripheral rim enhancement and mass-like enlargement decreased concomitantly on CT images (p < 0.001). Conclusion: CT may be helpful in diagnosing adrenal tuberculosis when clinically suspected, and CT features are correlated to the clinical duration of Addison's disease

  18. CT evaluation of cystic brain disease

    International Nuclear Information System (INIS)

    Kim, Joon Woo; Lee, Jin Woo; Joo, Yang Goo; Kim, Hong; Zeon, Seok Kil; Suh, Soo Jhi

    1987-01-01

    We retrospectively analysed CT findings of 47 cystic brain lesions of 44 patients, in which operation, biopsy or follow-up study was needed for their final diagnosis. The results were as follows: 1. The etiologic diseases of cystic brain lesions were 15 cases of brain abscess, 9 cases of astrocytoma, 5 cases of glioblastoma multiforme, 3 cases of meningioma, 5 cases of craniopharyngioma, 1 case of hemangioblastoma, 2 cases of dermoid cyst and 4 cases of metastasis. 2. We analyses the cystic lesions in view of their number, location, shape, perifocal edema, mass effect, wall and its thickness, evenness and characteristics of their inner and outer surfaces, mural nodule, calcification and contrast enhancement. a. 13.3% of brain abscess and 75% of metastases were multiple in number, but the remainder showed single lesion. b. The shape of cystic lesions were round or ovoid in 68%, lobulated in 8.5% and irregular in 23.5%, and no demonstrable difference of shape were noticed in different disease. c. In brain abscess, the wall of cystic lesions tend to be thin, even and smooth in inner surface, but the outer surfaces were equally smooth or irregular. d. Mural nodules were found in nearly half of the cases of astrocytoma, glioblastoma multiforme, metastasis and hemangioblastoma, but the brain abscess and dermoid cyst contained no mural nodule. e. Meningiomas were found to be attached to dura mater and showed thickening of the inner table of adjacent skull or of the falx. f. The presence of preceding infectious disease may be helpful in the diagnosis of brain abscess, but in 20% there were no demonstrable preceding infection. g. Lung cancer was confirmed as primary site in two of the cystic metastatic disease, but other 2 cases showed no demonstrable primary malignancy

  19. CT evaluation of cystic brain disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joon Woo; Lee, Jin Woo; Joo, Yang Goo; Kim, Hong; Zeon, Seok Kil; Suh, Soo Jhi [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    1987-10-15

    We retrospectively analysed CT findings of 47 cystic brain lesions of 44 patients, in which operation, biopsy or follow-up study was needed for their final diagnosis. The results were as follows: 1. The etiologic diseases of cystic brain lesions were 15 cases of brain abscess, 9 cases of astrocytoma, 5 cases of glioblastoma multiforme, 3 cases of meningioma, 5 cases of craniopharyngioma, 1 case of hemangioblastoma, 2 cases of dermoid cyst and 4 cases of metastasis. 2. We analyses the cystic lesions in view of their number, location, shape, perifocal edema, mass effect, wall and its thickness, evenness and characteristics of their inner and outer surfaces, mural nodule, calcification and contrast enhancement. a. 13.3% of brain abscess and 75% of metastases were multiple in number, but the remainder showed single lesion. b. The shape of cystic lesions were round or ovoid in 68%, lobulated in 8.5% and irregular in 23.5%, and no demonstrable difference of shape were noticed in different disease. c. In brain abscess, the wall of cystic lesions tend to be thin, even and smooth in inner surface, but the outer surfaces were equally smooth or irregular. d. Mural nodules were found in nearly half of the cases of astrocytoma, glioblastoma multiforme, metastasis and hemangioblastoma, but the brain abscess and dermoid cyst contained no mural nodule. e. Meningiomas were found to be attached to dura mater and showed thickening of the inner table of adjacent skull or of the falx. f. The presence of preceding infectious disease may be helpful in the diagnosis of brain abscess, but in 20% there were no demonstrable preceding infection. g. Lung cancer was confirmed as primary site in two of the cystic metastatic disease, but other 2 cases showed no demonstrable primary malignancy.

  20. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  1. Helical CT scan for emergent patients with cerebrovascular diseases

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio

    1995-01-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author)

  2. Helical CT scan for emergent patients with cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio [Fukushima Medical Coll. (Japan)

    1995-08-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author).

  3. Evaluation of left ventricular function by cardiac CT

    International Nuclear Information System (INIS)

    Naito, Hiroaki; Kozuka, Takahiro

    1982-01-01

    Left ventricular function was evaluated by CT, which was compared with the data of left ventriculography for various cardiac diseases. The end diastolic volume of the left ventricle can be readily computed from CT, with a satisfactory correlation with that of left ventriculography (r = 0.95). The left ventricular ejection fraction, calculated from the areal ratio of the left ventricular lumen in end-diastolic imaging to that in end-sytolic imaging, also roughly reflects left ventricular contractile function, but shows correlation with left ventriculography by only r = 0.79. Although the cardiac output is not sensitive for functional evaluation, it can be directly calculated by means of dynamic scanning and shows a satisfactory correlation with the ear piece pigment dilution (r = 0.85). Evaluation of left ventricular function by CT shows a high precision in comparison with left ventriculography, but still lacks temporal resolving power. (Chiba, N.)

  4. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  5. Vocal cord paralysis due to extralaryngeal causes : evaluation with CT

    International Nuclear Information System (INIS)

    Lee, Jong Hwa; Mo, Jong Hyun; Moon, Sung Hee; Na, Dong Gyu; Byun, Hong Sik; Cho, Jae Min; Han, Boo Kyung; Son, Young Ik; Baek, Chung Whan

    1999-01-01

    To evaluate the use of CT in patients with vocal cord paralysis due to extralaryngeal causes, and to use CT for the assessment of extralaryngeal diseases causing vocal cord paralysis. We prospectively studied the results of CT in 41 patients with vocal cord paralysis in whom laryngoscopy revealed no laryngeal cause and physical examination demonstrated no definite extralaryngeal cause. The extralaryngeal cause of vocal cord palsy was determined after comprehensive clinical diagnosis. Enhanced CT scans were acquired from the skull base and continued to the level of the aorticopulmonary window. We used CT to assess the detection rate for extralaryngeal causes and to extimate the extent of extralaryngeal disease and the distribution of lesions. CT revealed that in 20 of 41 patients(49%) the extralarygeal causes of vocal paralysis were as follows : thyroid cancer(n=10), nodal disease(n=6), esophageal cancer(n=2), neurogenic tumor(n=1), aortic aneurysm(n=1). Lesions were located on the left side in 13 patients(65%), and in the tracheoesophageal groove in 15(75%). In patients with vocal cord paralysis in whom no definite lesion is seen on physical examination , CT could be a useful primary imaging method for the assessment of extralaryngeal causes

  6. Usefulness of MR imaging for diseases of the small intestine: comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hoon; Ha, Hyun Kwon; Sohn, Min Jae; Shin, Byung Suck; Lee, Young Suk; Chung, Soo Yoon; Kim, Pyo Nyun; Lee, Moon Gyu; Auh, Yong Ho [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2000-03-01

    To evaluate the usefulness of MR imaging for diseases of the small intestine, emphasizing a comparison with CT. Thirty-four patients who underwent both CT and MR imaging using FLASH 2D and HASTE sequences were analyzed. All patients had various small bowel diseases with variable association of peritoneal lesions. We compared the detectabilities of CT and MR imaging using different MR pulse sequences. The capability for analyzing the characteristics of small intestinal disease was also compared. MR imaging was nearly equal to CT for detecting intraluminal or peritoneal masses, lesions in the bowel and mesentery, and small bowel obstruction, but was definitely inferior for detecting omental lesions. The most successful MR imaging sequence was HASTE for demonstrating bowel wall thickening, coronal FLASH 2D for mesenteric lesions, and axial FLASH 2D for omental lesions. MR imaging yielded greater information than CT in six of 12 inflammatory bowel diseases, while it was equal to CT in six of seven neoplasms and inferior in five of seven mesenteric ischemia. In determining the primary causes of 15 intestinal obstructions, MR imaging was correct in 11 (73%) and CT in nine (60%) patients. MR imaging can serve as an alternative diagnostic tool for patients with suspected inflammatory bowel disease, small intestinal neoplasm or obstruction.

  7. CT and MRI analysis of central nervous system Rosai-Dorfman disease

    International Nuclear Information System (INIS)

    Zhang Jiatang; Lang Senyang; Pu Chuanqiang; Zhu Ruyuan; Wang Dianjun

    2008-01-01

    Objective: To study the CT and MRI imaging features of central nervous system Rosai-Dorfman disease and to enhance knowledge and differential diagnostic ability for central nervous system Rosai-Doffman disease. Methods: The CT and MRI imaging appearances in 4 cases of pathologically proven Rosai-Dorfman disease were retrospectively evaluated and the literature of central nervous system Rosai- Dorfman disease were reviewed. Results: Two cases had cranial CT scans, 4 cases had cranial MRI scans. On CT scans, cerebral edema was demonstrated in one case and the other case was normal. MRI scans showed the lesions were solitary in saddle area in 3 cases, and multiple in anterior cranial fossa in 1 case. The lesions exhibited iso- to hypointensity on both T 1 WI and T 2 WI images. Following intravenous injection of contrast medium, ring-like enhancement was seen in 2 cases and homogeneous enhancement in 1 case. Nodular enhancement was seen in the case of multiple lesions in the anterior cranial fossa. All lesions were dural-based. Conclusions: In patients with fever, headache, elevation of the erythrocyte sedimentation rate (ESR) and a polyclonal increase in γ-globulins, the possibility of central nervous system Rosai-Dorfman disease should be considered when single or multiple dural-based mass lesions, especially in sellar region, were identified by CT and MRI. (authors)

  8. Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis

    International Nuclear Information System (INIS)

    Mori, Yoshiko; Yamasaki, Michio; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2001-01-01

    To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall was observed in all 29 cases of phlegmonous appendicitis (100%), but in only 66.7% (18 cases) of gangrenous appendicitis. Deficiency of the appendiceal wall was more frequently observed in gangrenous (19/27, 70.4%) than phlegmonous appendicitis (4/29, 13.8%). Findings of enhanced CT provide useful information in evaluating the pathological severity of acute appendicitis. (author)

  9. Characteristics of coronary artery disease in symptomatic type 2 diabetic patients: evaluation with CT angiography

    Directory of Open Access Journals (Sweden)

    Zhu Zhi-yu

    2010-11-01

    Full Text Available Abstract Background Coronary artery disease (CAD is a common and severe complication of type 2 diabetes mellitus (DM. The aim of this study is to identify the features of CAD in diabetic patients using coronary CT angiography (CTA. Methods From 1 July 2009 to 20 March 2010, 113 consecutive patients (70 men, 43 women; mean age, 68 ± 10 years with type 2 DM were found to have coronary plaques on coronary CTA. Their CTA data were reviewed, and extent, distribution and types of plaques and luminal narrowing were evaluated and compared between different sexes. Results In total, 287 coronary vessels (2.5 ± 1.1 per patient and 470 segments (4.2 ± 2.8 per patient were found to have plaques, respectively. Multi-vessel disease was more common than single vessel disease (p p p p p = 0.855. Extent of CAD, types of plaques and luminal narrowing were not significantly different between male and female diabetic patients. Conclusions Coronary CTA depicted a high plaque burden in patients with type 2 DM. Plaques, which were mainly calcified, were more frequently detected in the proximal segment of the LAD artery, and increased attention should be paid to the significant prevalence of obstructive stenosis. In addition, DM reduced the sex differential in CT findings of CAD.

  10. Value of PET/CT versus PET and CT performed as separate investigations in patients with Hodgkin's disease and non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Fougere, Christian la; Broeckel, Nicole; Pfluger, Thomas; Haug, Alexander; Scher, Bernhard; Hacker, Marcus; Hahn, Klaus; Tiling, Reinhold; Hundt, Walter; Reiser, Maximilan

    2006-01-01

    The aim of this study was to assess the clinical benefit of combined [ 18 F]FDG PET/CT in patients with malignant lymphoma as compared to separately performed PET and CT. Overall, 100 patients with Hodgkin's disease (HD) or non-Hodgkin's lymphoma (NHL) were included in this study. Co-registered PET/CT with [ 18 F]FDG and contrast medium was performed in 50 consecutive patients with NHL (n=38) or HD (n=12) for initial staging (IS) (n=12) or re-treatment staging (RS) (n=38). Another 50 patients with NHL (n=32) or HD (n=18) underwent separate PET and CT investigations within a time frame of 10 days for IS (n=22) or RS (n=28). Lymphoma involvement was separately evaluated for seven different regions in each patient. Each patient had clinical follow-up evaluation for >6 months. PET and CT data were analysed separately as well as side-by-side or in fused mode. In the PET/CT group, region-based evaluation for lymphoma involvement suggested a sensitivity/specificity of 85%/91% for CT, 98%/99% for PET and 98%/99% for PET/CT. In the PET and CT group, region-based evaluation showed a sensitivity/specificity of 87%/80% for CT, 98%/99% for PET and 98%/100% for PET and CT read side by side. PET was superior to CT alone and was improved further by side-by-side reading of both examinations. However, no significant difference was observed between PET/CT and separate PET and CT imaging in patients with lymphoma. (orig.)

  11. CT study in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji [Tokyo Metropolitan Matsuzawa Hospital (Japan)

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, II and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefore, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease.

  12. CT study in Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, Ii and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefor, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease. (J.P.N.)

  13. PET-CT in Staging, Response Evaluation, and Surveillance of Lymphoma.

    Science.gov (United States)

    Thanarajasingam, Gita; Bennani-Baiti, Nabila; Thompson, Carrie A

    2016-05-01

    Lymphoma represents a broad spectrum of diseases with diverse biology, clinical behavior, and imaging features. Functional imaging with 18-F-fluorodeoxyglucose (FDG)-positron emission tomography combined with computed tomography (PET-CT) is widely recognized as the most sensitive and specific imaging modality for patients with lymphoma and is used as part of staging, response evaluation, and surveillance in patients with Hodgkin (HL) and non-Hodgkin lymphoma (NHL). Recent efforts at standardizing the conduct and consensus interpretation of PET-CT have facilitated its use in patients on clinical studies and beyond. The role of PET-CT has been affirmed in some clinical situations, such as staging and end-of-treatment evaluation in Hodgkin lymphoma and diffuse large B cell lymphoma (DLBCL), and in the evaluation of aggressive transformation of an indolent lymphoma. However, the role of functional imaging in other histologies and clinical settings is not as clear given the higher rate of false positive results and the costs inherent to PET-CT. There is little evidence to suggest its utility or impact on outcome in most indolent lymphomas, or in the setting of post-treatment surveillance. In addition, there remains controversy about the value of PET-CT in early response assessment during active therapy, particularly in DLBCL. This review will evaluate the evidence surrounding the role of PET-CT in staging, response evaluation and surveillance of Hodgkin and non-Hodgkin lymphoma.

  14. CT evaluation of infectious colitis

    International Nuclear Information System (INIS)

    Horiki, Noriyuki; Maruyama, Masataka; Fujita, Yoshiyuki; Suzuki, Yuko; Tanaka, Tsuyoshi; Imoto, Ichiro; Adachi, Yukihiko

    2002-01-01

    Computed tomography (CT) is useful for evaluating the diagnosis of gastrointestinal disease, such as infectious colitis, in patients with severe pain and bloody diarrhea. During the 7 years between November 1993 and October 2000, 34 patients with infectious colitis (18 male, 16 female; mean age 42±19 yrs), received emergency CT and colonoscopy because of severe abdominal pain and dysentery. The following organisms were isolated: pathogenic Escherichia coli (12), 6 of which were O157: H7 (O-157), Salmonella species (11), Campylobacter species (5), Vibrio parahaemolyticus (3), Yersinia enterocolotica (2) and Shigella species (1). Thickening of the intestinal wall greater than 10 mm was seen in the ascending colon in the 6 cases with E. coli O157, in 5/11 cases with Salmonella, 4/5 with Campylobacter and 1/6 with non-O157 pathogenic E. Coli. marked intestinal wall thickening, greater than 20 mm, was seen in the ascending colon of the 4 of the patients with an O-157 infection. In all patients with O-157 colitis, slight ascites was noted in the pelvic space. In additions, ascites was also seen in 3/13 patients with Salmonella and 1/5 patients with Campylobacter colitis. The CT findings, in the patients with infectious colitis, are non-specific but knowledge and recognition of the findings will help in patient evaluation and proper treatment. (author)

  15. CT evaluation of infectious colitis

    Energy Technology Data Exchange (ETDEWEB)

    Horiki, Noriyuki; Maruyama, Masataka; Fujita, Yoshiyuki; Suzuki, Yuko [Saint Luke' s International Hospital, Tokyo (Japan); Tanaka, Tsuyoshi; Imoto, Ichiro [National Mie Chuo Hospital, Hisai (Japan); Adachi, Yukihiko [Mie Univ., Tsu (Japan). School of Medicine

    2002-08-01

    Computed tomography (CT) is useful for evaluating the diagnosis of gastrointestinal disease, such as infectious colitis, in patients with severe pain and bloody diarrhea. During the 7 years between November 1993 and October 2000, 34 patients with infectious colitis (18 male, 16 female; mean age 42{+-}19 yrs), received emergency CT and colonoscopy because of severe abdominal pain and dysentery. The following organisms were isolated: pathogenic Escherichia coli (12), 6 of which were O157: H7 (O-157), Salmonella species (11), Campylobacter species (5), Vibrio parahaemolyticus (3), Yersinia enterocolotica (2) and Shigella species (1). Thickening of the intestinal wall greater than 10 mm was seen in the ascending colon in the 6 cases with E. coli O157, in 5/11 cases with Salmonella, 4/5 with Campylobacter and 1/6 with non-O157 pathogenic E. Coli. marked intestinal wall thickening, greater than 20 mm, was seen in the ascending colon of the 4 of the patients with an O-157 infection. In all patients with O-157 colitis, slight ascites was noted in the pelvic space. In additions, ascites was also seen in 3/13 patients with Salmonella and 1/5 patients with Campylobacter colitis. The CT findings, in the patients with infectious colitis, are non-specific but knowledge and recognition of the findings will help in patient evaluation and proper treatment. (author)

  16. CT appearance of menetrier's disease (a report of 4 cases)

    International Nuclear Information System (INIS)

    Peng Weijun; Zhang Pei; Zhou Kangrong; Chen Huiming

    2000-01-01

    Objective: To define the CT imaging characteristic of menetrier's disease. Methods: Four patients with proved Menetrier's disease were retrospectively studied by means of CT performed with the water as oral contrast, hypotonic agent and dynamic or spiral CT technique. Results: All cases showed that the enlarged rugae were seen projecting into the gastric lumen, but the gastric wall was otherwise normal. CT detected all lesions and made a confirmed diagnosis before pathology biopsy. Conclusion: The primary result revealed that the CT appearance of Menetrier's disease was quite characteristic, CT is a very valuable tool for the diagnosis of Menetrier's disease

  17. Combined 18F-NaF and 18F-FDG PET/CT in the Evaluation of Sarcoma Patients.

    Science.gov (United States)

    Jackson, Tatianie; Mosci, Camila; von Eyben, Rie; Mittra, Erik; Ganjoo, Kristen; Biswal, Sandip; Gambhir, Sanjiv Sam; Iagaru, Andrei

    2015-09-01

    The combined administration of F-NaF and F-FDG in a single PET/CT scan has the potential to improve patient convenience and cancer detection. Here we report the use of this approach for patients with sarcomas. This is a retrospective review of 21 patients (12 men, 9 women; age, 19-66 years) with biopsy-proven sarcomas who had separate F-NaF PET/CT, F-FDG PET/CT, and combined F-NaF/F-FDG PET/CT scans for evaluation of malignancy. Two board-certified nuclear medicine physicians and 1 board-certified musculoskeletal radiologist were randomly assigned to review the scans. Results were analyzed for sensitivity and specificity, using linear regression and receiver operating characteristics. A total of 13 patients had metastatic disease on F-NaF PET/CT, F-FDG PET/CT, and combined F-NaF/F-FDG PET/CT. Skeletal disease was more extensive on the F-NaF PET/CT scan than on the F-FDG PET/CT in 3 patients, whereas in 1 patient, F-FDG PET/CT showed skeletal disease and the F-NaF PET/CT was negative. Extraskeletal lesions were detected on both F-FDG and combined F-NaF/F-FDG PET/CT in 20 patients, with 1 discordant finding in the lung. The combined F-NaF/F-FDG PET/CT scan allows for accurate evaluation of sarcoma patients. Further evaluation of this proposed imaging modality is warranted to identify the most suitable clinical scenarios, including initial treatment strategy and evaluation of response to therapy.

  18. PET-CT in the evaluation of metastatic breast cancer

    International Nuclear Information System (INIS)

    Sullivan, A.M.; Fulham, M.J.

    2005-01-01

    A 44-year-old woman underwent two PET-CT scans for the evaluation of metastatic breast cancer. A radical left mastectomy with axillary dissection (1 of 43 nodes positive) followed by chemotherapy, was performed in 1998. She represented in October 2003 with a left supraclavicular fossa mass. This was confirmed to be recurrent breast cancer on FNAB. She was considered for a radical neck dissection and the surgeon requested a PET scan. Other imaging at this time included a normal bone scan and CT brain. CT neck/chest/abdomen/pelvis showed soft tissue thickening in the left lower neck. The PET-CT scan showed multiple glucose avid lesions in the sternum, mediastinum and neck lymph nodes as well as a small lesion in the proximal left femur consistent with extensive metastatic disease. Surgery was cancelled and Femara chemotherapy commenced. Femara was stopped in March 2004 and the patient began alternative therapies. In October 2004 she presented to her surgeon with new back and chest pain. CT of the neck/chest/abdomen/pelvis showed a soft tissue mass in the upper sternum and a lymph node at the base of the neck highly suspicious for metastatic disease. There were also 2 suspicious lung nodules and a lesion in the proximal left femur reported as an osteoid osteoma. Wholebody PET-CT scans were performed on a Siemens LSO Biograph, 60mins after the injection of 350Mbq of Fl 8-Fag, with arms at the patient's side and head in the field-of-view. On both occasions the patient had to pay for the scan. On the 2004 PET-CT scan, the CT brain revealed multiple hyperdense lesions consistent with hemorrhagic metastases. In addition, there were innumerable glucose avid foci involving viscera, nodes and skeleton consistent with disseminated disease. Our case illustrates: (i) the value of PET in the management of metastatic breast cancer; (ii) the improved accuracy of PET-CT in delineating sites of disease; (iii) the issues of head movement in PET-CT and. (iv) the problem with lack of

  19. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  20. Interstitial lung disease in anti-synthetase syndrome: Initial and follow-up CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Debray, Marie-Pierre, E-mail: marie-pierre.debray@bch.aphp.fr [AP-HP, Bichat-Claude Bernard Hospital, Department of Radiology, 46, rue Henri Huchard, 75877 Paris Cedex 18 (France); Borie, Raphael, E-mail: raphael.borie@bch.aphp.fr [AP-HP, Bichat-Claude Bernard Hospital, Department of Pneumology A and Centre de Compétence Maladies Pulmonaires rares, DHU Fire 46, rue Henri Huchard, 75877 Paris Cedex 18 (France); Inserm, U1152, Paris (France); Revel, Marie-Pierre, E-mail: marie-pierre.revel@htd.aphp.fr [AP-HP, Cochin Hospital, Department of Radiology, 27, Rue du Fg Saint Jacques, 75679 Paris Cedex 14 (France); Naccache, Jean-Marc, E-mail: jean-marc.naccache@tnn.aphp.fr [AP-HP, Avicenne Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, Bobigny (France); AP-HP, Tenon Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, 4, rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine.khalil@tnn.aphp.fr [AP-HP, Tenon Hospital, Department of Radiology, 4, rue de la Chine, 75020 Paris (France); Toper, Cécile, E-mail: cecile.toper@gmail.com [AP-HP, Tenon Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, 4, rue de la Chine, 75020 Paris (France); Israel-Biet, Dominique, E-mail: dominique.israel-biet@egp.aphp.fr [Université Paris Descartes and AP-HP, Department of Pneumology, Georges Pompidou European Hospital, 20, rue Leblanc, 75015 Paris (France); and others

    2015-03-15

    Purpose: To describe the initial and follow-up CT features of interstitial lung disease associated with anti-synthetase syndrome (AS-ILD). Materials and methods: Two independent thoracic radiologists retrospectively analysed thin-section CT images obtained at diagnosis of AS-ILD in 33 patients (17 positive for anti-Jo1, 13 for anti-PL12, and three for anti-PL7 antibodies). They evaluated the pattern, distribution and extent of the CT abnormalities. They also evaluated the change in findings during follow-up (median 27 months; range 13–167 months) in 26 patients. Results: At diagnosis, ground-glass opacities (100%), reticulations (87%) and traction bronchiectasis (76%) were the most common CT findings. Consolidations were present in 45% of patients. A non-specific interstitial pneumonia (NSIP), organizing pneumonia (OP) or mixed NSIP-OP CT pattern were observed in 15 out of 33 (45%), seven out of 33 (21%) and eight out of 33 (24%) patients, respectively, whereas the CT pattern was indeterminate in three patients. During follow-up, consolidations decreased or disappeared in 11 out of 12 patients (92%), among which seven within the first 6 months, but honeycombing progressed or appeared in ten out of 26 patients (38%) and overall disease extent increased in nine out of 26 patients (35%). Conclusion: CT features at diagnosis of AS-ILD mainly suggest NSIP and OP, isolated or in combination. Consolidations decrease or disappear in most cases but the disease may progress to fibrosis in more than one third of patients.

  1. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nishio, Mizuho [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Koyama, Hisanobu [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Tsubakimoto, Maho [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nakagami-Gun, Okinawa (Japan); Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2014-02-15

    Purpose: To prospectively and directly compare oxygen-enhanced (O{sub 2}-enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O{sub 2}-enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O{sub 2}-enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O{sub 2}-enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD.

  2. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Tsubakimoto, Maho; Sugimura, Kazuro

    2014-01-01

    Purpose: To prospectively and directly compare oxygen-enhanced (O 2 -enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O 2 -enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O 2 -enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O 2 -enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD

  3. Assessment of airway lesion in obstructive lung diseases by CT

    International Nuclear Information System (INIS)

    Niimi, Akio; Matsumoto, Hisako; Ueda, Tetsuya; Mishima, Michiaki

    2002-01-01

    Airway lesion in obstructive pulmonary diseases, such as asthma or chronic obstructive pulmonary disease (COPD), has recently been assessed quantitatively. Especially in asthma, wall thickening of central airways, and its relation to the severity of disease or airflow obstruction has been clarified. Pathophysiologic importance of peripheral airway lesion has also been highlighted by pathologic or physiologic studies. However, direct evaluation of peripheral airway lesion is beyond resolutional limitation of CT. To assess airway trapping, an indirect CT finding of peripheral airway disease, by quantitative and semiquantitative measures and compare them with clinical indices such as pulmonary function, airway responsiveness, or airway inflammation. Patients with stable asthma (n=20) were studied. HRCT at 3 levels of both lungs were scanned. Low attenuation area (LAA)% and mean lung density were quantitatively assessed by an automatic method. Distribution of mosaic pattern was visually scored semiquantitatively. LAA% and mean lung density at full expiratory phase correlated with the degree of airflow obstruction. Mosaic score at full inspiratory phase correlated with the severity of disease and airflow obstruction. Expiratory/inspiratory ratio of mean lung density was also associated with airway responsiveness or residual volume/total lung capacity (RV/TLC). These CT findings may be useful as markers of asthma pathophysiology. (author)

  4. Role of FDG PET/CT in Baastrup's disease

    International Nuclear Information System (INIS)

    Subramanyam, Padma; Palaniswamy, Shanmuga Sundaram

    2016-01-01

    Baastrup's disease is a benign condition, which presents as chronic low back pain. It is also known as “kissing spine syndrome” and refers to close approximation of adjacent spinous processes producing inflammation and back pain. This condition is often misdiagnosed, resulting in incorrect treatment and persistence of symptoms. Diagnosis of Baastrup's disease is verified with clinical examination and imaging studies. Conventionally, clinicians resort to magnetic resonance imaging (MRI) of spine rather than X-ray or computed tomography (CT) in the evaluation of back pain. MRI can additionally identify flattening, sclerosis, enlargement, cystic lesions, and bone edema at the articulating surfaces of the two affected spinous processes. Studies have reported that 18 Fluorine fluorodeoxyglucose-positron emission tomography/CT (FDG-PET/CT) can detect a bursitis or an inflammation as a form of stress reaction despite a negative MRI and 99m Tc Methylene diphosphonate (MDP) bone scan. PET/CT is usually not a recommended investigation for this condition. However, this case report highlights the benefit of FDG-PET/CT in identifying the site of inflammatory pathology. It is also known to identify the exact site of inflammation where steroid or local anesthetic injection can be administered to alleviate pain, especially in patients with multilevel vertebral involvement

  5. CT scan of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, T; Noguchi, S; Nishitani, H [National Sanatorium of Utano, Kyoto (Japan); Kitano, H; Ikegami, Y

    1981-04-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs.

  6. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    Konishi, Tetsuro; Noguchi, Sadako; Nishitani, Hiroshi; Kitano, Haruo; Ikegami, Yoshinori.

    1981-01-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  7. Follow-up CT Evaluation of the Mural Changes in Active Takayasu Arteritis

    International Nuclear Information System (INIS)

    Kim, Sang Young; Park, Jae Hyung; Chung, Jin Wook; Kim, Hyo Cheol; Lee, Whal; So, Young Ho; Jae, Hwan Jun

    2007-01-01

    We wanted to evaluate the mural changes by CT on the follow-up examination of patients with active Takayasu arteritis. The study included 18 patients, (4 males and 14 females), with active Takayasu arteritis. A total of 44 CT examinations were done during the follow-up period (mean: 55.6 months). At the time of the last follow-up CT, the disease, on the basis of the erythrocyte sedimentation rate (ESR), was found to be inactive in five patients and the disease was active and persistent in 13 patients. The thickness and CT attenuation of the aortic wall on the precontrast, arterial and venous phases were measured on the initial and the follow-up CT examinations. The ratio of the mural attenuation over that of the back muscle on the initial CT was compared with the ratio found on the follow-up CT. The initial CT findings included high density and calcifications of the aortic wall in the precontrast images and a thickened wall with enhancements in the arterial and the venous phases. A low-attenuation ring was demonstrated in the venous phase in 15 patients (83%). On the follow-up evaluation, the mean mural thickness decreased significantly from 4.1 mm to 2.4 mm. The mean mural attenuation ratio in the venous phase decreased significantly from 1.9 to 1.3 (p 0.001). The low attenuation ring was identified in seven patients (39%) who had only with active, persistent Takayasu arteritis. The mural changes demonstrated by the follow-up CT evaluations for the patients with active Takayasu arteritis included a decrease of the mural thickness and enhancement, disappearance of the low-attenuation ring on the venous phase, and an increase of the mural attenuation and calcification on the precontrast phase

  8. Three-dimensional CT angiography in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Nakamura, Takeshi; Yoneda, Shigeru

    1995-01-01

    We reported the usefulness of three dimensional CT angiography (3 DCTA) in cerebrovascular disease. Twenty two of twenty three intracerebral aneurysms were visualized in 3 DCTA. 3 DTPA was especially useful for the evaluation of posterior-projection anterior communicating arteries and the distinction between a carotid-posterior communicating aneurysm and an infundibular dilatation. An anterior-projection carotid bifurcation aneurysm, which we missed in DSA, was visualized clearly in 3 DCTA. Stenotic cervical carotid artery lesions were well evaluated in 3 DCTA, including ulceration. 3 DCTA was not so useful for evaluation of intracranial artery stenosis. 3 DCTA was useful as a non-invasive method to evaluate cerebrovascular diseases. (author)

  9. Regional PET/CT after water gastric inflation for evaluating loco-regional disease of gastric cancer

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Lee, Won Woo; Yoon, Hai-Jeon; Lee, Ho-Young; Lee, Kyoung Ho; Kim, Young Hoon; Park, Do Joong; Kim, Hyung-Ho; So, Young

    2013-01-01

    Objective: We aimed to improve diagnostic accuracy of 18 F-fluoro-2-deoxyglucose (FDG) PET/CT for gastric cancer with water gastric inflation. Materials and methods: 44 gastric cancer patients (M:F = 30:14, age ± std = 62.1 ± 14.5y) were enrolled before surgery. Fifty minutes after injection of FDG (0.14 mCi/kg body weight), whole body PET/CT was performed first and then regional PET/CT over gastric area was obtained 80 min post FDG injection after water gastric inflation. Diagnostic accuracies for loco-regional lesions were compared between whole body and regional PET/CT. Results: 48 primary tumors (23 EGC and 25 AGC) and 348 LN stations (61 metastatic and 287 benign) in 44 patients were investigated. Primary tumor sensitivity of whole body PET/CT (50% = 24/48) was significantly improved by regional PET/CT (75% = 36/48, p < 0.005). Sensitivity of whole body PET/CT (24.6% = 15/61) for LN metastasis was also significantly improved by regional PET/CT (36.1% = 22/61, p < 0.01), whereas specificity of whole body PET/CT (99.3% = 285/287) was not compromised by regional PET/CT (98.3% = 282/287, p > 0.05). Higher primary tumor FDG uptake in regional PET/CT indicated shorter progress-free survival (p = 0.0003). Conclusion: Diagnostic accuracy of whole body PET/CT for loco-regional disease of gastric cancer could be significantly improved by regional PET/CT after water gastric inflation and prognosis could be effectively predicted by primary tumor FDG uptake in regional PET/CT

  10. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  11. CT and MR imaging of gynecological emergency disease

    International Nuclear Information System (INIS)

    Fujii, Shinya; Kinoshita, Toshibumi; Tahara, Takatoshi; Matsusue, Eiji; Ogawa, Toshihide

    2004-01-01

    We describe the CT and MRI findings of gynecologic emergency diseases: pelvic inflammatory disease, ectopic pregnancy, ovarian hemorrhage, ovarian torsion, rupture of ovarian tumor, eclampsia, and HELLP (hemolysis, elevated liver enzymes, and low platelet count) syndrome. Diagnostic keys to these diseases are presented in this review. CT and MRI play a complementary role to sonography in accurately diagnosing these diseases. In situations that require an exact, immediate diagnosis, radiologists should be familiar with the key imaging findings. (author)

  12. Utility of CT in the evaluation of pulmonary tuberculosis in patients without Aids

    International Nuclear Information System (INIS)

    Lee, K.S.; Hwang, J.W.; Chung, M.P.

    1997-01-01

    Objective. To assess the utility of CT in the evaluation of pulmonary tuberculosis in patients without AIDS. Patients and methods. Thin-section CT scans for suspicion of pulmonary tuberculosis were obtained from 226 patients. A total of 38 patients were excluded; the reasons were unavailability of final results (n=18), patient unavailability for follow-up (n=13), and coexistence of tuberculosis and aspergilloma (n=7). The results from 188 patients were used for this study. After assessing the patterns of parenchymal lesion, involved segments, and presence of cavity, bronchiectases, and bronchogenic spread of the lesion with CT, tentative diagnosis and disease activity were recorded. Results. With CT, 133 of 146 patients (91%) with tuberculosis were correctly diagnosed as having pulmonary tuberculosis whereas 32 of 42 patients (76%) without tuberculosis were correctly excluded. CT diagnosis of lung cancer (n=8), bacterial pneumonia (n=2), pulmonary metastasis (n=1), chronic hypersensitivity pneumonia (n=1) and diffuse pan-bronchiolitis (n=1) turned out to be tuberculosis. Conversely CT diagnoses of tuberculosis appeared pathologically as lung cancer (n=5), bacterial pneumonia 71/89, 80%) and inactive state (51/57, 89%) of disease respectively could be correctly differentiated by CT. Conclusion. CT can be helpful in the diagnosis of pulmonary tuberculosis in most cases. On the basis of CT findings, distinction of active from inactive disease can be made in most cases. (authors)

  13. Tomography methods for diagnostic examination of cerebrovascular disease: a comparative evaluation of SPECT, PET and MR/CT findings

    International Nuclear Information System (INIS)

    Reiche, W.; Kaiser, H.J.; Weiller, C.; Altehoefer, C.; Buell, U.; Isensee, C.

    1991-01-01

    Single Photon Emissions Computerized Tomography (SPECT), Positron Emissions Tomography (PET), Magnetic Resonance Tomography (MR), and Transmission Computerized Tomography (CT) complement each other and lead to a consideration of the cerebrovascular disease under patho-physiological aspects. Indications for the combined application of functionally oriented (SPECT/PET) and morphologically oriented (CT/MR) examination methods with cerebrovascular disease are presented. (orig./MG) [de

  14. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  15. MR imaging versus PET/CT for evaluation of pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Belião, Sara, E-mail: sara.beliao@clix.pt [Department of Radiology Hospital S. Francisco Xavier, Estrada do Forte do Alto do Duque, 1495-005 Lisbon (Portugal); Ferreira, Alexandra, E-mail: alexandratavaresferreira@gmail.com [Department of Radiology, Hospital D. Estefânia, Rua Jacinta Marto, 1169-045 Lisbon (Portugal); Vierasu, Irina, E-mail: Ortansa-Irina.Vierasu@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Blocklet, Didier, E-mail: dblockle@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Goldman, Serge, E-mail: petscan@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Metens, Thierry, E-mail: tmetens@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium); Matos, Celso, E-mail: cmatos@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium)

    2012-10-15

    Purpose: To retrospectively determine the diagnostic accuracy of magnetic resonance imaging (MRI) and combined positron emission tomography/computed tomography (PET/CT) in the differential diagnosis of benign and malignant pancreatic lesions. Materials and methods: Twenty-seven patients (15 women/12 men, mean age 56.5 years) with MR imaging and PET/CT studies performed to differentiate benign and malignant pancreatic lesions were identified between October 2008 and October 2010. Both MR and PET/CT data sets were retrospectively and blindly evaluated by two independent readers (4 readers total) with different degrees of experience, using a visual five-point score system. The results were correlated with final diagnosis obtained by histopathology. Results: 17 patients had malignant diseases and 10 patients had benign diseases. Depending on the observer, the sensitivity, specificity, positive predictive value and negative predictive value of MRI varied between 88–94%, 50–80%, 75–89% and 71–89% respectively. Sensitivities, specificities, positive predictive values and negative predictive values of PET/CT were 73%, 56%, 73% and 56% respectively. The diagnostic accuracy of MR for the differential diagnosis of pancreatic lesions was 74–89%, compared with 67% for PET/CT. The weighted Cohen's kappa coefficient was 0.47 at MR and 0.53 at PET/CT. Conclusion: MRI achieved higher sensitivity and specificity in the differential diagnosis of pancreatic lesions.

  16. Localized Castleman's disease: CT and MRI findings

    International Nuclear Information System (INIS)

    Chen Zuhua; Yang Guangzhao

    2008-01-01

    Objective: To study the CT and MRI findings of localized Castleman's disease (LCD). Methods: The CT (n=7) and MRI (n=2) appearance of LCD (n=7) confirmed by pathology and operation were retrospectively analyzed. Results Hyaline-vascular type(n=6) and plasma cell type (n=1) were confirmed by pathology in LCD (n=7). They were located in middle mediastinum (n=2), hilum pulmonis (n=l), posterior mediastinum (n=3), retro-peritoneum (n=1). Hyaline-vascular type focuses in CT scanning were manifested as round shape soft tissue masses, with homogeneous density, integrity envelope, distinct margin, and chaperonage arborizing and spot calcification. Marked persistent enhancement was apparent on contrast CT. MRI findings of hyaline-vascular type (n=2) was slightly isointense or hyperintense on T 1 WI, homogeneous hyperintense on T 2 WI, similar enhancement with CT after contrast. Plasma cell type focus were unhomogeneous density with abnormity necrosis, media and unhomogeneous enhancement after contrast. Conclusion: Marked persistent enhancement of LCD would be helpful to diagnosis and differential diagnosis in Castleman's disease. (authors)

  17. Castleman disease of the neck: CT and MR imaging findings

    International Nuclear Information System (INIS)

    Jiang, Xin-hua; Song, Hao-ming; Liu, Qing-yu; Cao, Yun; Li, Guo-hong; Zhang, Wei-dong

    2014-01-01

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases

  18. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  19. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  20. Comparison of CT enterography and MR enterography imaging features of active Crohn disease in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Gale, Heather I. [The Warren Alpert Medical School of Brown University, Department of Diagnostic Imaging, Rhode Island Hospital/Hasbro Children' s Children' s Hospital/Women and Infants Hospital, Providence, RI (United States); Sharatz, Steven M.; Nimkin, Katherine; Gee, Michael S. [MassGeneral Hospital for Children, Division of Pediatric Imaging, Department of Radiology, Harvard Medical School, Boston, MA (United States); Taphey, Mayureewan [Bumrungrad International Hospital, Bangkok (Thailand); Bradley, William F. [Cambridge Mobile Telematics, Cambridge, MA (United States)

    2017-09-15

    Assessment for active Crohn disease by CT enterography and MR enterography relies on identifying mural and perienteric imaging features. To evaluate the performance of established imaging features of active Crohn disease in children and adolescents on CT and MR enterography compared with histological reference. We included patients ages 18 years and younger who underwent either CT or MR enterography from 2007 to 2014 and had endoscopic biopsy within 28 days of imaging. Two pediatric radiologists blinded to the histological results reviewed imaging studies and scored the bowel for the presence or absence of mural features (wall thickening >3 mm, mural hyperenhancement) and perienteric features (mesenteric hypervascularity, edema, fibrofatty proliferation and lymphadenopathy) of active disease. We performed univariate analysis and multivariate logistic regression to compare imaging features with histological reference. We evaluated 452 bowel segments (135 from CT enterography, 317 from MR enterography) from 84 patients. Mural imaging features had the highest association with active inflammation both for MR enterography (wall thickening had 80% accuracy, 69% sensitivity and 91% specificity; mural hyperenhancement had 78%, 53% and 96%, respectively) and CT enterography (wall thickening had 84% accuracy, 72% sensitivity and 91% specificity; mural hyperenhancement had 76%, 51% and 91%, respectively), with perienteric imaging features performing significantly worse on MR enterography relative to CT enterography (P < 0.001). Mural features are predictors of active inflammation for both CT and MR enterography, while perienteric features can be distinguished better on CT enterography compared with MR enterography. This likely reflects the increased conspicuity of the mesentery on CT enterography and suggests that mural features are the most reliable imaging features of active Crohn disease in children and adolescents. (orig.)

  1. Role of CT/PET in predicting nodal disease in head and neck cancers

    International Nuclear Information System (INIS)

    Singham, S.; Iyer, G.; Clark, J.

    2009-01-01

    Full text:Introduction: Pre-treatment evaluation of the presence of cervical nodal metastases is important in head and neck cancers and has major prognostic implications. In this study, we aim to determine the accuracy of CT/PET as a tool for identifying such metastases. Methods: All patients from Royal Prince Alfred and Liverpool Hospitals, who underwent CT/PET for any cancer arising from the head and neck, and who underwent subsequent surgery (which included a neck dissection) within 8 weeks of the CT/PET were included. Nodal staging was undertaken by utilising imaging-based nodal classification, and comparison with pathologic data from the surgical specimen was made. PET was considered positive if the SUV was greater than 2. Results: We identified 111 patients from the above criteria. 80 of such patients were treated for squamous cell carcinoma (SCC). CT/PET identified unsuspected metastatic disease in 6 patients. Correlation of CT/PET findings and the presence of disease at the primary site: sensitivity: 98%, specificity: 93%, positive predictive value (PPV): 98% and negative predictive value (NPV): 93%. Correlating CT/PET findings with the presence of nodal disease at any level: sensitivity: 95%, specificity: 88%, PPV: 95% and NPV: 88%. CT/PET was anatomically accurate in predicting the site of metastases in 62/74 (84%). Conclusion: PET is accurate in predicting both presence of nodal metastases and the level of involvement. CT/PET should be undertaken as a pre-operative tool to assist in planning the extent of surgery required in head and neck cancers.

  2. CT evaluation of abdominal trauma

    International Nuclear Information System (INIS)

    Huang Ruiting

    2004-01-01

    Objective: An evaluation of CT diagnosis of abdominal trauma. Methods: CT appearance of abdominal trauma was analyzed retrospectively in 95 cases. thirty-three patients were cured by operation, and the other 59 patients received conservative treatment. Fifty-one patients out of 59 were seen healed or improved by a follow up CT scan after the conservative treatment. Results: The study included: 31 cases of splenic contusion, accompanying with hemoperitoneum in 25 cases; 3 cases of hepatic laceration; 33 cases of liver and spleen compound trauma accompanying with hemoperitoneum; 18 cases of renal contusion, with subcapsular hemorrhage in 12 cases; 4 cases of midriff colic; 3 cases of mesentery breach; 3 cases of digestive tract perforation. Conclusion: CT is sensitive and precise in evaluating abdominal trauma, providing important information for treatment. (author)

  3. Haemodynamic findings on cardiac CT in children with congenital heart disease

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2011-01-01

    In patients with congenital heart disease, haemodynamic findings demonstrated on cardiac CT might provide useful hints for understanding the haemodynamics of cardiac defects. In contrast to morphological features depicted on cardiac CT, such haemodynamic findings on cardiac CT have not been comprehensively reviewed in patients with congenital heart disease. This article describes normal haemodynamic phenomena of cardiovascular structures and various abnormal haemodynamic findings with their mechanisms and clinical significance on cardiac CT in patients with congenital heart disease. (orig.)

  4. Evaluation of diffuse hepatic disease by computed tomography, 1

    International Nuclear Information System (INIS)

    Tada, Akira; Shikae, Mikio; Morinaga, Kenichi; Morikawa, Toshihiro; Nei, Hirokazu.

    1979-01-01

    Liver attenuation values of 53 diffuse hepatic disease were measured, and compared with those of normal subjects. In normal subjects mean CT values of the liver was 62.3, that of the spleen was 53.2. But in diffuse hepatic disease, all group's mean CT values of the liver was decreased, especially at fatty liver and acute hepatitis. In all cases of fatty liver, CT values of the liver were lower than that of the spleen. In 39 cases of 53 patients, change of CT values of the liver were measured using biliary tract contrast agents. In another 39 cases of 53 patients, were evaluated histological fat deposit and CT values of the liver. Correlation between histological fat deposit and CT values was good. Diagnosis of the moderate fatty liver and quantitative analysis was possible by CT values alone. (author)

  5. CT and MR imaging in the evaluation of leptomeningeal metastases

    International Nuclear Information System (INIS)

    Xiao Jiahe; Wang Dayou; Deng Kaihong

    1999-01-01

    Objective: To study the manifestations of leptomeningeal metastases on CT and MR imaging, and evaluate the diagnostic significance of both modalities for this disease. Methods: Clinical and neuroradiological data of 21 cases with leptomeningeal metastases were retrospectively reviewed. In this series, 16 patients were studied by CT and 7 patients by MRI, 2 patients by both CT and MRI. Results: Abnormal enhancement of pia and subarachnoid space, appearing as diffuse pattern in 10 cases, nodular pattern in 8 cases and mixed pattern with diffuse plus nodules in 3 cases, were visualized by CE-CT and Gd-MRI. Diffuse enhancement followed the convolutions of gyri and surface of brainstem, and extended into cerebral cisterns and sulci. the foci appeared as enhanced nodules 0.2-3.0 cm in diameter and 1 or more in number. Nodules with infiltration of cerebral parenchymal were found in 4 patients. In 86% of all cases, diffuse or nodular foci occurred in basilar systems and adjacent cerebellar and cerebral sulci. There were 4 cases associated with ependymal nodular enhancement and 10 cases with widened irregular tentorial enhancement. Intracerebral metastases in 9 cases and hydrocephalus in 13 cases were found in this series. Conclusions: CE-CT and Gd-MRI are had significant clinical diagnostic value for leptomeningeal metastases, Gd-MRI is superior to CE-CT. Because of the limitation in the evaluation of leptomeningeal invasion by neoplasms on CT and MRI, definitive diagnosis of leptomeningeal metastases depends on combination of clinical and imaging data

  6. Comparison of Xenon-Enhanced Area-Detector CT and Krypton Ventilation SPECT/CT for Assessment of Pulmonary Functional Loss and Disease Severity in Smokers.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Takenaka, Daisuke; Kaminaga, Shigeo; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2018-02-01

    The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81m Kr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV 1 ) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. Multivariate logistic regression showed that %FEV 1 was significantly affected (r = 0.77, r 2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). Xenon-enhanced ADCT is more effective than 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.

  7. Helical CT of ureteral disease

    International Nuclear Information System (INIS)

    Cikman, Pablo; Bengio, Ruben; Bulacio, Javier; Zirulnik, Esteban; Garimaldi, Jorge

    2000-01-01

    Among the new applications of helical CT is the study of the ureteral pathology. The objective of this paper was to evaluate patients with suspected pathology of this organ and the repercussion in the therapeutic plans. We studied 23 patients with a helical CT protocol, without IV contrast injection and performed multiplanar reconstruction (MPR). We called this procedure Pielo CT. Thirteen ureteral stones were detected, 6 calculi, 2 urinary tract tumors, dilatation of the system in a patient with neo-bladder. In 2 patients, in whom ureteral pathology was ruled out, we found other alterations that explained the symptoms, (gallbladder stones, disk protrusion). The Pielo CT let decide a therapeutical approach in 20 or 21 patients with ureteral pathology. (author)

  8. Role of FDG PET/CT in Diagnostic Evaluation of Granulocytic Sarcomas: A Series of 12 Patients.

    Science.gov (United States)

    Chandra, Piyush; Dhake, Sanket; Purandare, Nilendu; Agrawal, Archi; Shah, Sneha; Rangarajan, Venkatesh

    2017-01-01

    Granulocytic sarcoma (GS) is a rare extramedullary manifestation in patients with acute myeloid leukemia (AML), which can precede the diagnosis or occur in the posttreatment setting. Unlike its established role in other hematological malignancies like Hodgkin's on non-Hodgkin's disease, the exact role of positron emission tomography/computed tomography (PET/CT) in AML with or without GS remains to be defined. We retrospectively reviewed PET/CT scans of 12 patients with histologically proven GS. Marrow examination of these patients identified nine patients with isolated GS (without existent leukemia) and three patients with coexistent leukemia. PET/CT accurately identified all clinically evident GS in all 12 patients at initial staging and at follow-up with tumors, showing moderate to high 2-deoxy-2-fluoro-D-glucose uptake. Coexistent marrow disease was seen on PET/CT in three patients, which was confirmed on histopathology. In the same patients, PET/CT also detected additional sites of extramedullary disease in 66.6% (n = 8), which was either clinically occult or not evident on routine CT. PET/CT appears to be a highly sensitive imaging modality in diagnostic evaluation of GS. The most important indication of using PET/CT in these cases is to identify additional sites of clinically occult extramedullary disease, which can potentially impact treatment decisions and outcomes.

  9. CT in the evaluation of patients on ECMO due to acute respiratory failure

    International Nuclear Information System (INIS)

    Lidegran, Marika; Jorulf, Haakan; Palmer, Kenneth; Linden, Viveka

    2002-01-01

    Heading AbstractBackground. In patients with acute severe respiratory failure (ARF) treated with extracorporeal membrane oxygenation (ECMO) the radiological evaluation has until now almost exclusively relied on bedside radiography and US. At St. Goeran/Karolinska ECMO centre CT has become a routine complement to bedside examinations.Objective. To review retrospectively the frequency, indications and findings on CT of patients with ARF on ECMO and to evaluate the risk of complications associated with transportation for CT examinations.Materials and methods. One hundred twelve neonates, children and adults were treated with ECMO from May 1994 to January 2001. Forty-six per cent of these patients had CT examinations on one or more occasions during ECMO, giving a total number of 238 examination sites on 104 occasions. All CT examinations were performed in the Paediatric Radiology Department and included a 10-min transport using a mobile ECMO system.Results. CT was more often performed in older patients and in patients with long ECMO runs. The main indications were suspected complications of ECMO and/or the underlying disease or a delay in clinical improvement. In 57% of the CT occasions, significant findings affecting treatment were revealed. There were no complications associated with the examinations or transport.Conclusions. CT is safe and useful in evaluation of patients with ARF during ECMO. (orig.)

  10. Uncommon locations of hydatid disease: CT appearances

    International Nuclear Information System (INIS)

    Gossios, K.J.; Kontoyiannis, D.S.; Dascalogiannaki, M.; Gourtsoyiannis, N.C.

    1997-01-01

    Hydatid disease (HD), already known by Hippocrates, is prevalent and widespread in most sheep-raising countries in Asia, Australia, South America, Near East, and southern Europe. The disease is most commonly due to Echinococcus granulosus and may occur in any organ or tissue. The location is mostly hepatic (75%) and pulmonary (15%), and only 10% occur in the rest of the body. Imaging modalities such as US, CT, and MR imaging are helpful in diagnosing the disease. The reliability of each method depends on the cyst's location in the body. The purpose of this essay is to illustrate the use of CT in depicting some unusual locations of HD besides the liver and lung. (orig.). With 18 figs

  11. Uncommon locations of hydatid disease: CT appearances

    Energy Technology Data Exchange (ETDEWEB)

    Gossios, K.J.; Kontoyiannis, D.S. [Department of Radiology, General Hospital of Ioannina, GR-450 01 Ioannina (Greece); Dascalogiannaki, M.; Gourtsoyiannis, N.C. [Department of Radiology, University of Crete Medical School, GR-711 10 Iraklion (Greece)

    1997-10-01

    Hydatid disease (HD), already known by Hippocrates, is prevalent and widespread in most sheep-raising countries in Asia, Australia, South America, Near East, and southern Europe. The disease is most commonly due to Echinococcus granulosus and may occur in any organ or tissue. The location is mostly hepatic (75%) and pulmonary (15%), and only 10% occur in the rest of the body. Imaging modalities such as US, CT, and MR imaging are helpful in diagnosing the disease. The reliability of each method depends on the cyst`s location in the body. The purpose of this essay is to illustrate the use of CT in depicting some unusual locations of HD besides the liver and lung. (orig.). With 18 figs.

  12. Value of computed tomography in diagnosis of intestinal diseases. CT findings in nontumoral bowel diseases

    Energy Technology Data Exchange (ETDEWEB)

    Fujikawa, Koichi; Yamane, Kosuke; Nakanishi, Tadashi; Miura, Yoshio; Kato, Yoshitaka; Yahata, Noriko; Iwamoto, Toshiyuki; Katayama, Hiroshi; Katsuta, Shizutomo

    1987-03-01

    CT findings of 46 cases with inflammatory and other nontumoral bowel diseases were retrospectively studied. Patients were given 500 to 1000 ml of lukewarm water orally or rectally to distend the intestinal lumen. In all cases water-soluble iodine contrast media was administered intravenously. The CT findings in Crohn's disease included mural thickening, luminal narrowing, bowel wall enhancement, wall rigidity, serration of intestinal border, dilatation of mesenteric vessels, periintestinal blurring (inflamatory reaction of mesentery), fibrofatty proliferation, effusion, abscess and fistula. Many of these findings suggested the transmural nature of the disease and gave diagnostic clues of the disease. In cases with ulcerative colitis, thickening of bowel wall was insignificant and extraintestinal complications were absent. CT appears to play an important role in distinguishing Crohn's disease and ulcerative colitis. Luminal narrowing and mural thickening were also observed in a case with intestinal ischemia, but these mural changes were not accompanied by mesenteric abnormalities to the degree of Crohn's disease. In cases with penetrating peptic ulcer and diverticulitis, CT demonstrated inflammatory reactions of surrounding tissue such as thickening of neighboring fascia, increase in attenuation value of mesenteric fat, effusion and abscess. Even in cases with confusing clinical symptoms, appendicitis was easily diagnosed on CT which showed swelling of appendix and inflammatory changes of surrounding structures. Mechanical obstruction of the intestine could be identified on CT by a notable change of luminal sizes at the site of obstruction. CT appearances of intussusception were distinctive and a soft tissue mass (intussusceptum) and mesenteric fat was seen within a markedly dilated intussuscipiens. CT could also reveal pancreatitis and splenic infarction as the causes of clinically-undiagnosed paralytic ileus. (J.P.N.).

  13. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  14. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Latson, Larry A.; Truong, Mylene T.; Aaltonen, Eric; Shiau, Maria C.; Girvin, Francis; Alpert, Jeffrey B.; Wickstrom, Maj; Ko, Jane P.

    2016-01-01

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  15. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: bedros.taslakian@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Latson, Larry A., E-mail: larry.latson@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Truong, Mylene T., E-mail: mtruong@mdanderson.org [Department of Radiology, University of Texas, MD Anderson Cancer Center, TX (United States); Aaltonen, Eric, E-mail: Eric.Aaltonen@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Shiau, Maria C., E-mail: Maria.Shiau@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Girvin, Francis, E-mail: Francis.Girvin@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Alpert, Jeffrey B., E-mail: Jeffrey.Alpert@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Wickstrom, Maj, E-mail: Maj.Wickstrom@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Ko, Jane P., E-mail: Jane.Ko@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States)

    2016-11-15

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  16. CT evaluation of chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Willemink, M.J. [Department of Radiology, St Antonius Hospital, Nieuwegein (Netherlands); Es, H.W. van, E-mail: h.es@antoniusziekenhuis.nl [Department of Radiology, St Antonius Hospital, Nieuwegein (Netherlands); Koobs, L. [Department of Radiology, St Antonius Hospital, Nieuwegein (Netherlands); Morshuis, W.J. [Department of Cardio-Thoracic Surgery, St Antonius Hospital, Nieuwegein (Netherlands); Snijder, R.J. [Department of Pulmonary Disease, St Antonius Hospital, Nieuwegein (Netherlands); Heesewijk, J.P.M. van [Department of Radiology, St Antonius Hospital, Nieuwegein (Netherlands)

    2012-03-15

    The educational objectives of this article are to provide an overview of the computed tomography (CT) findings in chronic thromboembolic pulmonary hypertension. This article reviews the key imaging findings at CT in patients with chronic thromboembolic pulmonary hypertension. After reading this article, the reader should have an improved awareness of the condition, its imaging features, and the CT imaging features associated with surgically accessible disease.

  17. CT evaluation of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Willemink, M.J.; Es, H.W. van; Koobs, L.; Morshuis, W.J.; Snijder, R.J.; Heesewijk, J.P.M. van

    2012-01-01

    The educational objectives of this article are to provide an overview of the computed tomography (CT) findings in chronic thromboembolic pulmonary hypertension. This article reviews the key imaging findings at CT in patients with chronic thromboembolic pulmonary hypertension. After reading this article, the reader should have an improved awareness of the condition, its imaging features, and the CT imaging features associated with surgically accessible disease.

  18. Computed tomographic evaluation in 8 patient of cerebrovascular moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Young Tae; Lee, Jung Suk; Suh, Soo Jhi; Kim, Soon Yong [School of Medicine, Kyung-Hee University Hospital, Seoul (Korea, Republic of)

    1980-12-15

    CT findings in eight cerebrovascular moyamoya disease were compared with carotid angiographic findings and the results were as follows: 1. The patient's age was ranged from 2 to 49 years. Of eight patients, five were less than 17 years old and the rests were two 23 years and one 49 years of age. 2. Except one 6 years old boy, all of them were female patients. 3. In precontrast CT scan of 8 cases, 6 cases of cortical atrophy, 6 cases of ventricular dilatation and 5 cases of low density area were observed. In postcontrast study the children group shows abnormal contrast enhancement in 3 out of 5 patients but all adult reveal no contrast enhancement. 4. The isodense area in CT were thought to represent good collateral manifested by angiographic moyamoya vascular network and leptomeningeal anastomosis while the low density area in CT appears to poor colleaterals manifested by transdural anastomosis. 5. To evaluate the possibility of this disease, carotid angiography should be performed to the hemiplgic child who shows multiple low density area and abnormal enhancement in CT scan. 6. CT is not only reliable for evaluation of ventricular hemorrhage but also brain damage in patients with moyamoya disease.

  19. Ultrasound and computer tomography in the evaluation of focal liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Bartolozzi, C; Ciatti, S; Lucarelli, E; Villari, N; de Dominicis, R [Florence Univ. (Italy). Ist. di Radiologia

    1981-01-01

    The results of ultrasound and computer tomography in 150 patients with possible focal liver disease were compared. Ultrasound was more sensitive than CT in detecting lesions but similar information on the nature of the lesion was obtained with both methods. CT provided more complete information than US on the extent of the lesion. Thus, CT and US are supplementary in the evaluation of focal liver disease. Because of the higher sensitivity US should be the first examination, followed, if clinically indicated, by CT for confirmation and possible further information regarding the extent of the lesion.

  20. Correlation of CT perfusion and CT volumetry in patients with Alzheimers disease

    International Nuclear Information System (INIS)

    Czarnecka, A.; Zimny, A.; Sasiadek, M.

    2010-01-01

    Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimers disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. (authors)

  1. Is PET/CT efficient tool to evaluate the response after stereotactic radiation therapy for pancreas cancer?

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seong Yul; Cho, Chul Koo

    2005-01-01

    In pancreas cancer, to evaluate the efficacy of PET/CT as tool to check the response after stereotactic radiation therapy and to define functional imaging role of PET/CT as alterative tool of computed tomography. From November 2003 to December 2004, among locally advanced pancreas cancer patients treated by stereotactic radiation therapy using CyberKnife(CK), 14 were evaluated by PET/CT before and after treatment. Four patients took PET/CT one month after CK, 4 patients 2 months after CK, and 6 patients 3 months after CK as the first evaluation of treatment. All of patients were also evaluated by CT or CA19-9 tumor antigen with the range of 1-2 months after CK. In addition of PET/CT to CT, lymph node metastasis were revealed as positive in 4 patients who had negative finding on CT. Furthermore, patients who showed partial or complete response on PET/CT findings that checked within 3 months after CK have significantly longer median survival time than patients who showed no response or disease progression(13 months and 9 months, respectively). Responses based on CA19-9 tumor antigen or CT, however, showed no significant difference in terms of median survival time. PET/CT can provide more information for lymph node metastasis compared to CT alone. It is very helpful for delineation of tumor extent for CK planning. And initial response on PET/CT scan could be a significant prognostic factor rather than response on CA19-9 level or CT. In the future, more study is necessary to evaluate if PET/CT could substitute CT and finally CT could be omitted during follow-up period after CK

  2. CT findings of orbital inflammatory diseases

    International Nuclear Information System (INIS)

    Kim, Jang Min; Shin, Hyun Joon; Kim, Jung Hyuk; Suh, Won Hyuck

    1991-01-01

    Twenty-nine patients with orbital inflammatory disease (OIDs) were retrospectively reviewed in order to analyze detailed CT findings which might aid in differentiating OIDs. This study comprised 18 pseudotumors, 5 thyroid ophthalmopathies, and 6 cases of orbital cellulitis. CT scans of the pseudotumors showed various findings such as exophthalmos, scleritis, myositis of the extraocular muscle (MOM), and bone lesion. Bone lesions of the pseudo tumors, which have been rarely reported, were present in 7 cases in our series. Bilateral exophthalmos, myositis, and retrobulbar fat deposition were readily detected by CT in thyroid ophthalmopathy, and, in addition, we found bone erosions involving the orbital apices in 2 cases. In orbital cellulitis, extraorbital soft tissue swelling and lateral displacement of the medial rectus muscle in cases with ethmoiditis were the most conspicuous features. In summary, because of the overlapping CT findings in OIDs, careful examination of CT findings regarding the mode of EOM involvement and the presence or absence of scleritis or sinusitis might help narrow down the differential diagnosis. A pseudotumor with bone lesions could be mistaken as a malignant lesion, and therefore it is necessary to correlate clinical features with CT findings for an accurate diagnosis

  3. The usefulness of CT scanning in clinical observation on the patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Golebiowski, M.; Barcikowska, M.; Pfeffer-Baczuk, A.; Luczywek, E.

    1994-01-01

    On the basis of brain CT studies of 150 patients of the clinic for persons with Alzheimer's disease the diagnostic utility of measurement of hippocampal fissure and craniocerebral ratios was assessed. In analyzed group hippocampal fissure measurements greater than 4 mm occurred only in patients with symptoms of Alzheimer's type dementia. The measurement showed 90% sensitivity and 70% specificity as the prognostic factor of clinical course, especially at the first part of the disease. The evaluation of the hippocampal fissure in conjunction with detailed analysis of CT picture of the atrophic brain allowed for precise final diagnosis. (author)

  4. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Archana [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); St. Christopher' s Hospital for Children, Department of Radiology, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); New York Cardiovascular Institute at Lenox Hill Radiology, New York, NY (United States); Servaes, Sabah; Keller, Marc S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Schwartz, Mathew C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Levine Children' s Hospital, Sanger Heart and Vascular Institute, Charlotte, NC (United States); Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging/Radiology, Orlando, FL (United States)

    2017-03-15

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  5. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Malik, Archana; Hellinger, Jeffrey C.; Servaes, Sabah; Keller, Marc S.; Schwartz, Mathew C.; Epelman, Monica

    2017-01-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  6. Comparison of CT and scintigraphy in diseases of the liver

    International Nuclear Information System (INIS)

    Wenig, H.G.; Wegener, O.H.; Souchon, R.; Ziegler, U.; Koppenhagen, K.

    1979-01-01

    Sixty-five patients with various diseases of the liver were examined by CT and scintigraphy. We found the following preliminary conclusions: diffusely infiltrative and hepatocellular diseases of the liver, espacially cirrhosis, are recognized on CT by shape and contour rather than by density values. In these cases, scintigraphy provides important information about the function of the parenchyma. In space-occupying processes, a close correlation exists between CT and scintigraphy. In the investigation of liver metastases in advanced stages, CT and radionuclide studies proved to be nearly identical in accuracy. The advantages of CT consist in the possibility of showing more morphologic detail of adjacent organs and in possessing better spatial resolution. (orig.) 891 MG/orig. 892 MB [de

  7. Positron emission CT and X-ray CT findings in chronic obstructive pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yoshikazu; Murata, Kiyoshi; Ito, Harumi; Senda, Michio; Yonekura, Yoshiharu; Konishi, Junji; Nishimura, Koichi; Izumi, Takahide; Oshima, Shunsaku

    1987-08-01

    Positron emission CT and X-ray CT were performed in fifteen patients with emphysema confirmed SAB and twelve patients with clinical DPB. In patients with emphysema, 20 of 36 areas showed a central pattern and their perfusion scintigrams showed stripe-signs. On the other hand, the patients with DPB showed outer layer progression of the disease.

  8. Current Roles and Future Applications of Cardiac CT: Risk Stratification of Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeonyee Elizabeth [Department of Cardiology, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Lim, Tae-Hwan [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 138-736 (Korea, Republic of)

    2014-07-01

    Cardiac computed tomography (CT) has emerged as a noninvasive modality for the assessment of coronary artery disease (CAD), and has been rapidly integrated into clinical cares. CT has changed the traditional risk stratification based on clinical risk to image-based identification of patient risk. Cardiac CT, including coronary artery calcium score and coronary CT angiography, can provide prognostic information and is expected to improve risk stratification of CAD. Currently used conventional cardiac CT, provides accurate anatomic information but not functional significance of CAD, and it may not be sufficient to guide treatments such as revascularization. Recently, myocardial CT perfusion imaging, intracoronary luminal attenuation gradient, and CT-derived computed fractional flow reserve were developed to combine anatomical and functional data. Although at present, the diagnostic and prognostic value of these novel technologies needs to be evaluated further, it is expected that all-in-one cardiac CT can guide treatment and improve patient outcomes in the near future.

  9. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    International Nuclear Information System (INIS)

    Kamijo, Keiichi

    1994-01-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122±18 H.U.(±SD) and did not change significatly with advancing age. The mean thyroid CT number (±SD) of 85±22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116±22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T 3 were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65±11 H.U. and increased significantly to 76±14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102±11 H.U. and fell significantly to 84±16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57±7 H.U. in 6 patients with silent thyroiditis and of 61±5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author)

  10. CT diagnosis of colonic lymphadenitis in the cat-scratch disease

    International Nuclear Information System (INIS)

    Zhuang Xiongjie; Wang Jingqun

    2004-01-01

    Objective: To make a further understanding of CT manifestations of colonic lymphadenitis in the cat scratch disease (CSD). Methods: The clinical data and CT features of colonic lymphadenitis in two cases of CSD were analyzed retrospectively. Results: Both patients had cat contact history. The CT findings were colonic lymphadenitis with solid mass, and marked enhancement after contrast administration. There were no colon narrownest and necrosis of colonic mucous membranes, besides lymph node enlargement along the regional lymphatic drainage. Conclusion: Combination of the cat contact history, CT scanning is of great value in the cat scratch disease. (authors)

  11. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  12. Diagnostic value of CT scanning in neuromuscular diseases

    International Nuclear Information System (INIS)

    Bulcke, J.A.L.; Leuven Univ.; Herpels, V.

    1983-01-01

    The diagnosis of myopathies has become easier since the CT technique is available. In this article the possibilities of CT for diagnostic procedures of neuromuscular diseases are pointed out. Density measurements increase differentiation of atrophy or hypertrophy of muscles as well as other pathological changes. (orig.)

  13. The diagnosis of MR and CT scan for myofascitis of connective tissue disease: comparison with biopsy examination

    International Nuclear Information System (INIS)

    Xu Jianrong; Zhou Yan; Chai Weimin; Yao Qiuying; Li Lei; Li Lan; Li Zhengyang

    2002-01-01

    Objective: To evaluate the utility of MRI, CT and biopsy examinations in detecting myofascitis lesions of connective tissue disease. Methods: The study group consisted of 22 patients proven by clinical features and laboratory examination, including 8 cases of dermatomyositis (DM), 12 cases of polymyositis (PM), and 2 cases of eosinophilic fascitis. All patients received CT scan, SE-T 1 WI, SE-T 2 WI, SPIR, and CT guiding biopsy at the thigh region. Results: Biopsy detected muscular diseases in 17 cases and fascitis in 5 cases. MRI detected muscular diseases in 14 and fascitis in 9. CT detected muscular diseases in 5 and fascitis in 9. Myositis, amyotrophy, and fascitis may be alone or united in one case. Myositis (9 cases) appeared as low signal on T 1 WI and high signal on T 2 WI or SPIR. Amyotrophy (9 cases) presented hyperintensity on both T 1 WI and T 2 WI. SPIR was more sensitive in detecting myositis than CT and T 1 WI, P < 0.05. Myositis was more frequent in cases with DM(6/8) than in cases with PM (3/12), P < 0.05. Also, myositis was more frequently encountered in active phase (7/11) than in quiescent phase (2/11). Conclusion: MRI and CT appear to be valuable in quantitatively and qualitatively estimating myofascitis of connective tissue diseases

  14. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  15. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  16. CT evaluation of mass lesions in the parotid region

    International Nuclear Information System (INIS)

    Matsumoto, Shunichi; Kishikawa, Takashi; Kudo, Sho; Miyaji, Hiroshi; Kuwano, Haruo; Kaneko, Kuniyuki; Ohuchida, Toshiyuki

    1988-01-01

    CT findings of 35 patients with proven 31 parotid gland mass lesions (23 benign tumors, 5 malignant tumors, 3 inflammatory diseases) and 4 infraauricular lymphadenopathy (2 inflammatory nodes, 2 neoplastic nodes) were reviewed. CT accurately diagnosed the parotid origin in 29 of 31 parotid gland diseases. In all four patients with infraauricular lymphadenopathy, differentiation from parotid tumor was difficult. CT differentiation between superficial and deep lobe tumors agreed with surgical findings in 18 of 21 parotid gland tumors. Twenty out of 23 benign parotid gland tumors appeared as discrete masses with smooth margins. All five malignant parotid gland tumors appeared as poorly defined masses. It is concluded that when a tumor is located in the superficial lobe and appears as a sharply circumscribed mass on plain CT, it should be diagnosed as a benign lesion and contrast CT is not required. Secondly, contrast CT would be beneficial when a tumor is indistinct, or located in the deep portion of the parotid gland on plain CT. Finally, CT-sialography is considered unnecessary in the diagnosis of parotid masses. (author)

  17. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    Energy Technology Data Exchange (ETDEWEB)

    Kamijo, Keiichi (Kamijo Thyroid and Pituitary Clinic, Sapporo (Japan))

    1994-02-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122[+-]18 H.U.([+-]SD) and did not change significatly with advancing age. The mean thyroid CT number ([+-]SD) of 85[+-]22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116[+-]22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T[sub 3] were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65[+-]11 H.U. and increased significantly to 76[+-]14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102[+-]11 H.U. and fell significantly to 84[+-]16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57[+-]7 H.U. in 6 patients with silent thyroiditis and of 61[+-]5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author).

  18. Computer- Aided diagnosis system for the evaluation of chronic obstructive pulmonary disease on CT Images

    Directory of Open Access Journals (Sweden)

    Parsa Hosseini M

    2011-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Chronic Obstructive Pulmonary Disease (COPD is one of the most prevalent pulmonary diseases. Use of an automatic system for the detection and diagnosis of the disease will be beneficial to the patients' treatment decision-making process. In this paper, we propose a new approach for the Computer Aided Diagnosis (CAD of the disease and determination of its severity axial CT scan images."n"nMethods: In this study, 24 lung CT scans in full inspiratory and expiratory states were performed. Variations in the normalized pattern of the lungs' external parenchyma were exploited as a feature for COPD diagnosis. Subsequently, a Bayesian classifier was used to classify variations into two normal and abnormal patterns for the discrimination of patients and healthy individuals. Finally, the accuracy of the classification was assessed statistically. "n"nResults: With the proposed method, the lungs parenchymal elasticity and air-trapping were determined quantitatively. The more this feature tended to zero, the more severe air-trapping and obstructive pulmonary disease is. By analyzing CT images in the healthy and patient groups, we calculated the hard threshold for the diagnosis of the disease. Clinical results

  19. Grading of Crohn's disease activity using CT, MRI, US and scintigraphy: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Puylaert, C.A.J.; Tielbeek, J.A.W.; Bipat, S.; Stoker, J. [University of Amsterdam, Academic Medical Center, Department of Radiology, Amsterdam (Netherlands)

    2015-11-15

    To assess the grading of Crohn's disease activity using CT, MRI, US and scintigraphy. MEDLINE, EMBASE and Cochrane databases were searched (January 1983-March 2014) for studies evaluating CT, MRI, US and scintigraphy in grading Crohn's disease activity compared to endoscopy, biopsies or intraoperative findings. Two independent reviewers assessed the data. Three-by-three tables (none, mild, frank disease) were constructed for all studies, and estimates of accurate, over- and under-grading were calculated/summarized by fixed or random effects models. Our search yielded 9356 articles, 19 of which were included. Per-patient data showed accurate grading values for CT, MRI, US and scintigraphy of 86 % (95 % CI: 75-93 %), 84 % (95 % CI: 67-93 %), 44 % (95 % CI: 28-61 %) and 40 % (95 % CI: 16-70 %), respectively. In the per-patient analysis, CT and MRI showed similar accurate grading estimates (P = 0.8). Per-segment data showed accurate grading values for CT and scintigraphy of 87 % (95 % CI: 77-93 %) and 86 % (95 % CI: 80-91 %), respectively. MRI and US showed grading accuracies of 67-82 % and 56-75 %, respectively. CT and MRI showed comparable high accurate grading estimates in the per-patient analysis. Results for US and scintigraphy were inconsistent, and limited data were available. (orig.)

  20. CT SCAN EVALUATION OF PULMONARY NODULE

    Directory of Open Access Journals (Sweden)

    A. Ravi Kumar

    2016-06-01

    Full Text Available BACKGROUND Lung carcinomas are quite commonly diagnosed. Thanks to the ever increasing smokers’ population. Majority of the city dwellers are at a higher risk of having this disease when compared to the village counterparts. The stigma through which the person and the family have to undergo before confirming the diagnosis is enormous. So the radiographic methods of diagnosing the malignancies have to improve. Before confirming the diagnosis, the radiologists, the treating physicians should be somewhat confident about the diagnosis so as to prepare the patients and their relatives for the most probable diagnosis before the confirmatory report. The confirmatory procedures include the PET scan and the Histopathology. Both are time consuming procedures and in an economy like ours, finding a PET scanning centre is rather difficult. So the most probable diagnosis has to be thought of using minimal resource. This study puts in a sincere effort to understand and evaluate the pulmonary nodule when identified by a CT scan. This paper is intended to help the practicing radiologists and also make life easy for a practicing physician to identify correctly the lesions and also help the patients to prevent further progression of the disease. METHODS The study was a cross-sectional study. The sample size of the study consisted of thirty patients. CT scan was done in thirty patients who were identified to have lung nodules either by other mode of radiological studies or first time identified in a CT scan itself. The study was conducted in Fathima Institute of Medical Sciences, Kadapa. The study was conducted from 2014 to 2015. RESULT Non-solid nodules were more in number when compared to the solid nodules. All the non-solid nodules were confirmed to be adenomas. Eighty percent of the nodules which were more than 8 mm in size were confirmed to be malignant. One hundred percent of the spiculated border on CT was confirmed to be malignant. In the present study

  1. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections.

    Science.gov (United States)

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  2. CT of cerebral hydatid disease

    Energy Technology Data Exchange (ETDEWEB)

    Rudwan, M.A.; Khaffaji, S.

    1988-12-01

    Six cases of cerebral hydatid disease (CHD) were seen in Kuwait over a period of 8 years. The typical CT appearance of a large well-defined spherical nonenhanced unilocular cyst was seen in four cases. Two unusual but characteristic types of calcification were seen, one in each of the remaining two cases.

  3. CT of cerebral hydatid disease

    International Nuclear Information System (INIS)

    Rudwan, M.A.; Khaffaji, S.

    1988-01-01

    Six cases of cerebral hydatid disease (CHD) were seen in Kuwait over a period of 8 years. The typical CT appearance of a large well-defined spherical nonenhanced unilocular cyst was seen in four cases. Two unusual but characteristic types of calcification were seen, one in each of the remaining two cases. (orig.)

  4. Mixed connective tissue disease associated with noted pulmonary CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Souji; Tsukada, Atsuko; Furuya, Tatsutaka

    1984-10-01

    CT was performed in a 56-year-old woman with mixed connective tissue disease (MCTD). Much more definitive pulmonary findings were obtained by CT than by the conventional chest x-ray examination and pulmonary function test. CT findings disclosed pulmonary lesions extremely similar to those in cases of progressive systemic sclerosis. Pulmonary CT was considered useful in examining pulmonary lesions for MCTD.

  5. Evaluation of computed tomography in the diagnosis of liver diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kato, K; Takayama, T; Katada, N; Nishimura, D; Shibata, T [Kamo Hospital, Toyota, Aichi (Japan)

    1980-10-01

    In order to evaluate computed tomography (CT) in the diagnosis of liver disease, 90 cases of diffuse parenchymal diseases and 37 cases of mass lesions were examined with a GE 8800 CT scanner. Abnormal CT findings in liver cirrhosis were characterized by splenomegaly, uneven liver margin and asites. Atrophy of right lobe and enlargement of left lobe could not be easily recognized on CT scan, compared with nuclear imaging. CT values of the liver were decreased and the ratios of CT values of the liver to those of the spleen were less than 0.9 in all cases with fatty liver. Jaundice in acute viral hepatitis can be easily differentiated from obstructive jaundice on CT scan because of observing no dilatation of intrahepatic bile duct. CT was superior in detecting space-occupying lesions to nuclear imaging and was more specific in that it was able to differentiate cystic from solid lesions. However, it was almost impossible to make a histological diagnosis of solid lesions even on CT scan.

  6. Evaluation of computed tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Kato, Katsumoto; Takayama, Tetsuo; Katada, Naoyuki; Nishimura, Daisaku; Shibata, Tokimune

    1980-01-01

    In order to evaluate computed tomography (CT) in the diagnosis of liver disease, 90 cases of diffuse parenchymal diseases and 37 cases of mass lesions were examined with GE 8800 CT scanner. Abnormal CT findings in liver cirrhosis were characterized by splenomegaly, uneven liver margin and asites. Atrophy of right lobe and enlargement of left lobe could not be easily recognized on CT scan, compared with nuclear imaging. CT values of the liver were decreased and the ratios of CT values of the liver to those of the spleen were less than 0.9 in all cases with fatty liver. Jaundice in acute viral hepatitis can be easily differentiated from obstructive jaundice on CT scan because of observing no dilatation of intrahepatic bile duct. CT was superior in detecting space-occupying lesions to nuclear imaging and was more specific in that it was able to differentiate cystic from solid lesions. However, it was almost impossible to make a histological diagnosis of solid lesions even on CT scan. (author)

  7. Preliminary evaluation of helical CT colonography in detection of colonic diseases compared with double contrast barium enema

    International Nuclear Information System (INIS)

    Zhai Xiaoli; Zhang Lei; Zhai Renyou; Li Jie; Wang Yajie; Ding Yi

    2000-01-01

    Objective: To evaluate helical CT colonography in regard to technology principles, limitations, and clinical applications. Methods: Fifty-six patients underwent volume scanning using helical CT. The diseases included adenocarcinoma 39, adenomatous polyp 3, multiple diverticular 7, mucocele of appendix 1, and normal colon 6. All cases had been compared with double contrast barium enema (DCBE), proved by histology except the 6 normal colon and the 7 multiple diverticular. All CTC images were reconstructed using shaded surface display (SSD) on workstation. Then, perspective images such as the ones from DCBE were generated via ray sum. The images could clearly demonstrate the extent and detail of the disorder by using 'CUT' software, 'revolve' function, and zoom. Results: CTC correctly demonstrated 3-5 mm diverticulum, 3 mm ulcer, and 6 mm polyps. Not only show colon straitness clearly, CTC is also very sensitive to demonstrate the stenotic end of masses. In these cases, discovery rate of CTC is 100.0%, the rate of DCBE is 88.6%; CTC is more sensitive than DCBE in cases of tumor nodules. Ray sum can show the boundary of colonic mass extending to both proximal and distal ends, its discovery rate is 62.6%. Accuracy of localization for CTC is 100.0%. Conclusion: CTC is a novel technique for detecting colonic diseases. It is a safe, accurate, and non-invasive means for detection of lesions and is an efficient complement for DCBE. Further development in CTC technique is expected in the future

  8. Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease

    International Nuclear Information System (INIS)

    Saad, Moez Ben; Rohnean, Adela; Sigal-Cinqualbre, Anne; Adler, Ghazal; Paul, Jean-Francois

    2009-01-01

    There are only a few reports on the diagnostic accuracy, and the technical and clinical feasibility, of multidetector CT (MDCT) in infants with congenital heart disease (CHD). To evaluate the image quality and radiation dose of DSCT in babies with CHD. From November 2006 to November 2007, 110 consecutive infants with CHD referred for pre- or postoperative CT evaluation were included. All these infants had a spiral angiothoracic DSCT scan after injection of 300 mg/ml iopromide at 0.5-1 ml/s with a power injector using a low-dose protocol (80 kVp and 10 mAs/kg). Of these infants, 34 also underwent an ECG-gated coronary CT scan for evaluation of the course of the coronary arteries. No serious adverse events were recorded. The mean dose-length product was 8±6 mGy.cm (effective dose 0.5±0.2 mSv) and 21±9 mGy.cm (effective dose 1.3±0.6 mSv) during the non-ECG-gated spiral acquisition and ECG-gated acquisition, respectively. Diagnostic quality images were achieved with the spiral acquisition in 89% of cases. Compared to the spiral mode, ECG-gated acquisition significantly improved the visualization of the coronary arteries, with a diagnostic rate of 91% and 84% for the left and right coronary arteries, respectively. DSCT together with iopromide at 300 mg/ml is a valuable tool for the routine clinical evaluation of infants with CHD. ECG-gated acquisition provides reliable visualization of the course of the coronary arteries. (orig.)

  9. Nontuberculous Mycobacterial (NTM) Disease in Immunocompetent Patients: Expanding Image Findings on Chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyo Hyun; Seon, Hyun Ju; Kim, Mok Hee; Choi, Song; Song, Sang Gook; Shin, Sang Soo; Kim, Yun Hyeon; Park, Jin Gyoon [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2010-04-15

    The aim of this study was to evaluate the chest CT features of nontuberculous mycobacterial (NTM) disease regardless of the specific organisms. This study included 74 consecutive patients (35 men, 39 women; mean age, 63 years; age range, 25-89 years) who were diagnosed with NTM disease according to the American Thoracic Society Guidelines (1997 and 2007) between January 2005 and July 2007. Chest CT images were randomly reviewed by two radiologists with consensus. The most common organism associated with NTM disease is M. avium-intracellulare complex (87.8%), followed by M. abscesses, M. kansasii, and M. chelonae. The most common chest CT finding was a nodular bronchiectatic lesion (n = 35, 46.7%), followed by a cavitary lesion of the upper lobe (n = 21, 28.0%), combined lesions of two prior subtypes (n = 6, 8.0%), consolidative lesion (s) (n = 5, 6.7%), a bronchogenic spreading pulmonary tuberculosis-like lesion (n = 5, 6.7%), a cavitary mass lesion with small satellite nodules (n = 2, 2.7%), and a miliary nodular lesion (n = 1, 1.3%). More than 5 segments were involved in 60 cases (81.1%). The nodular bronchiectatic lesion or cavitary lesion of upper lobe presents with multi-segmental involvement and the occurrence of combined consolidation is indicative of NTM disease

  10. Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Kagel, Thomas; Nicolas, Volkmar [Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Bochum (Germany); Mueller, Klaus-Michael [Ruhr-University of Bochum, Institute of Pathology, BG Clinics Bergmannsheil, Bochum (Germany); Nuesslein, Thomas G.; Rieger, Christian H.L. [Ruhr-University of Bochum, Pediatric Hospital, Bochum (Germany)

    2005-07-01

    Children with chronic infectious interstitial lung disease often have to undergo open lung biopsy to establish a final diagnosis. Open lung biopsy is an invasive procedure with major potential complications. Transthoracic lung biopsy (TLB) guided by computed tomography (CT) is a less-invasive well-established procedure in adults. Detailing the role of low-dose CT-guided TLB in the enhanced diagnosis of chronic lung diseases related to infection in children. A group of 11 children (age 8 months to 16 years) underwent CT-guided TLB with a 20-gauge biopsy device. All investigations were done under general anaesthesia on a multidetector CT scanner (SOMATOM Volume Zoom, Siemens, Erlangen, Germany) using a low-dose protocol (single slices, 120 kV, 20 mAs). Specimens were processed by histopathological, bacteriological, and virological techniques. All biopsies were performed without major complications; one child developed a small pneumothorax that resolved spontaneously. A diagnosis could be obtained in 10 of the 11 patients. Biopsy specimens revealed chronic interstitial alveolitis in ten patients. In five patients Chlamydia pneumoniae PCR was positive, in three Mycoplasma pneumoniae PCR was positive, and in two Cytomegalovirus PCR was positive. The average effective dose was 0.83 mSv. Low-dose CT-guided TLB can be a helpful tool in investigating chronic infectious inflammatory processes in children with minimal radiation exposure. It should be considered prior to any open surgical procedure performed for biopsy alone. In our patient group no significant complication occurred. A disadvantage of the method is that it does not allow smaller airways and vessels to be assessed. (orig.)

  11. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  12. Mixed connective tissue disease associated with noted pulmonary CT findings

    International Nuclear Information System (INIS)

    Yamazaki, Souji; Tsukada, Atsuko; Furuya, Tatsutaka

    1984-01-01

    CT was performed in a 56-year-old woman with mixed connective tissue disease (MCTD). Much more definitive pulmonary findings were obtained by CT than by the conventional chest x-ray examination and pulmonary function test. CT findings disclosed pulmonary lesions extremely similar to those in cases of progressive systemic sclerosis. Pulmonary CT was considered useful in examining pulmonary lesions for MCTD. (Namekawa, K.)

  13. Radical pancreatectomy: postoperative evaluation by CT

    Energy Technology Data Exchange (ETDEWEB)

    Heiken, J.P.; Balfe, D.M.; Picus, D.; Scharp, D.W.

    1984-10-01

    Twenty-four patients who had undergone radical pancreatic resection were evaluated by CT one week to 11 years after surgery. Eighteen patients had had the Whipple procedure; six had had total pancreatectomy. The region between the aorta and superior mesenteric artery, previously occupied by the uncinate process of the pancreas, is an important area to evaluate for tumor recurrence because periampullary tumors tend to metastasize to the lymph nodes in this region. Tumor recurrence here is readily detectable by CT since radical pancreatectomy leaves this area area free of soft tissue attenuation material. CT demonstrated postoperative complications or tumor recurrence in 16 of the 24 patients and was 100% accurate in patients who had follow-up.

  14. Radical pancreatectomy: postoperative evaluation by CT

    International Nuclear Information System (INIS)

    Heiken, J.P.; Balfe, D.M.; Picus, D.; Scharp, D.W.

    1984-01-01

    Twenty-four patients who had undergone radical pancreatic resection were evaluated by CT one week to 11 years after surgery. Eighteen patients had had the Whipple procedure; six had had total pancreatectomy. The region between the aorta and superior mesenteric artery, previously occupied by the uncinate process of the pancreas, is an important area to evaluate for tumor recurrence because periampullary tumors tend to metastasize to the lymph nodes in this region. Tumor recurrence here is readily detectable by CT since radical pancreatectomy leaves this area area free of soft tissue attenuation material. CT demonstrated postoperative complications or tumor recurrence in 16 of the 24 patients and was 100% accurate in patients who had follow-up

  15. Dynamic CT brain scanning in the haemodynamic evaluation of cerebral arterial occlusive disease

    International Nuclear Information System (INIS)

    Davis, S.M.; Melbourne Univ.; Tress, B.M.; Hopper, J.L.; Rossiter, S.C.; Kaye, A.H.

    1987-01-01

    Dynamic cerebral CT scanning (DCT) was used to quantitatively analyse the haemodynamic effects of extracranial and intracranial arterial occlusive lesions in 17 patients with TIA's or minor cerebral infarcts. Using DCT and gamma variate curve fitting, mean transit times were determined for the terminal internal carotid arteries, middle cerebral arteries and middle cerebral-supplied Sylvian cortex at the level of the Circle of Willis. Six patients were studied sequentially, four before and after transcranial bypass surgery. No arterial or tissue delays were found in patients without haemodynamic arterial lesions or cortical infarcts. Seven of nine patients with haemodynamic, extracranial carotid lesions showed ipsilateral delays in arterial or tissue transit times. Tissue delays usually correlated with CT or clinical evidence of infarction. Improved haemodynamics in patients re-studied correlated with the effects of surgery or clinical recovery. DCT has several important limitations but has the potential to provide additional haemodynamic information about the cerebral circulation in selected patients with cerebral arterial occlusive disease. (orig.)

  16. Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

    Science.gov (United States)

    Leiva-Salinas, C; Flors, L; Gras, P; Más-Estellés, F; Lemercier, P; Patrie, J T; Wintermark, M; Martí-Bonmatí, L

    2014-01-01

    CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders. © 2014 by American Journal of Neuroradiology.

  17. Serial CT scans and Menkes' kinky hair disease

    International Nuclear Information System (INIS)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-01-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 μ g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died. (author)

  18. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  19. Gaucher disease of the liver: CT appearance

    International Nuclear Information System (INIS)

    Glass, R.B.J.; Poznanski, A.K.; Young, S.; Urban, M.A.

    1987-01-01

    We present a child with Gaucher disease with hepatic involvement that caused portal hypertension. Computerized tomography (CT) showed distortion of liver parenchyma and central necrosis of the liver. (orig.)

  20. Detection and Severity Scoring of Chronic Obstructive Pulmonary Disease Using Volumetric Analysis of Lung CT Images

    International Nuclear Information System (INIS)

    Hosseini, Mohammad Parsa; Soltanian-Zadeh, Hamid; Akhlaghpoor, Shahram

    2012-01-01

    Chronic obstructive pulmonary disease (COPD) is a devastating disease.While there is no cure for COPD and the lung damage associated with this disease cannot be reversed, it is still very important to diagnose it as early as possible. In this paper, we propose a novel method based on the measurement of air trapping in the lungs from CT images to detect COPD and to evaluate its severity. Twenty-five patients and twelve normal adults were included in this study. The proposed method found volumetric changes of the lungs from inspiration to expiration. To this end, trachea CT images at full inspiration and expiration were compared and changes in the areas and volumes of the lungs between inspiration and expiration were used to define quantitative measures (features). Using these features,the subjects were classified into two groups of normal and COPD patients using a Bayesian classifier. In addition, t-tests were applied to evaluate discrimination powers of the features for this classification. For the cases studied, the proposed method estimated air trapping in the lungs from CT images without human intervention. Based on the results, a mathematical model was developed to relate variations of lung volumes to the severity of the disease. As a computer aided diagnosis (CAD) system, the proposed method may assist radiologists in the detection of COPD. It quantifies air trapping in the lungs and thus may assist them with the scoring of the disease by quantifying the severity of the disease

  1. Complicated pleural tuberculosis in children: CT evaluation

    International Nuclear Information System (INIS)

    Moon, W.K.; Kim, W.S.; Kim, I.O.; Im, J.G.; Kim, J.H.; Yeon, K.M.; Han, M.C.

    1999-01-01

    Purpose. To describe the CT features of complicated pleural tuberculosis in children and to define the use of CT in children with pleural tuberculosis. Materials and methods. The CT findings in 11 children with complicated pleural tuberculosis were retrospectively analysed. CT was performed to evaluate persistent pleural thickening (n = 6) or a mass-like lesion (n = 5) detected on plain radiographs. Chest radiographs and medical records were reviewed to determine whether additional information provided by CT had altered clinical management. Results. On CT, more than one location was involved in five patients (45 %) and in two patients (18 %) the entire pleural spaces were involved. Pleural thickening was seen in all 11 patients and enhancement after administration of contrast medium occurred in ten patients (91 %). Low-density fluid collections were seen in nine patients (82 %) and in two, CT revealed fluid collections within calcified pleural lesions. In five patients with mass-like lesions on plain radiographs, CT showed a low-density pleural mass with peripheral enhancement in four and a calcified pleural mass with fluid collection in one. CT demonstrated parenchymal abnormalities on the same side as pleural lesions in all 11 patients and hilar or mediastinal adenopathy in four. Four patients (36 %) underwent surgery because of fluid within a calcified fibrothorax (n = 3) and chest wall tuberculosis (n = 1) that were seen only on CT. Conclusions. The CT features of complicated pleural tuberculosis in children were pleural thickening, enhancement and fluid collection with associated parenchymal abnormalities and lymphadenopathy. In the evaluation of children with pleural tuberculosis, CT can be useful for demonstrating fluid within a calcified fibrothorax or chest wall involvement, which usually requires surgical intervention. (orig.)

  2. Cerebral atrophy in Parkinson's disease - represented in CT

    International Nuclear Information System (INIS)

    Becker, H.; Schneider, E.; Hacker, H.; Fischer, P.A.; Frankfurt Univ.

    1979-01-01

    To clarify the importance of brain atrophy in relation to the symptoms of Parkinson's disease, 173 patients were examined by computed tomography (CT). In 51.4% of the CT findings, brain atrophy was considered to be pathological. Statistically significant relations of age and sex were found with regard to the extent and localization of brain atrophy. Cortical atrophy also showed a significant dependence on duration of disease. Linear measurements at the lateral ventricles and the third ventricle lead us to assume that brain atrophy in Parkinson's patients is more prevalent than in normal patients within the scope of age involution. (orig.)

  3. Cerebral atrophy in Parkinson's disease - represented in CT

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H; Schneider, E; Hacker, H; Fischer, P A [Frankfurt Univ. (Germany, F.R.). Abt. fuer Neuroradiologie; Frankfurt Univ. (Germany, F.R.). Abt. fuer Neurologie)

    1979-01-01

    To clarify the importance of brain atrophy in relation to the symptoms of Parkinson's disease, 173 patients were examined by computed tomography (CT). In 51.4% of the CT findings, brain atrophy was considered to be pathological. Statistically significant relations of age and sex were found with regard to the extent and localization of brain atrophy. Cortical atrophy also showed a significant dependence on duration of disease. Linear measurements at the lateral ventricles and the third ventricle lead us to assume that brain atrophy in Parkinson's patients is more prevalent than in normal patients within the scope of age involution.

  4. 18FFDG PET in evaluating malignancies compared with CT, MRI and pathology in 58 cases

    International Nuclear Information System (INIS)

    Li, L.

    2000-01-01

    This article discussed the practical application of 18 F-FDG PET imaging techniques to depict, state, or define recurrences for five important malignancies: lung cancer, colorectal and head-and-neck cancer, intracranial malignant glioma and primary or secondary hepatic malignant diseases. And comparisons of 18 F-FDG PET with CT, MRI imaging were addressed specifically. We reviewed our initial experience with 48 malignant and ten non-malignant cases. Among malignant group, 36 cases were confirmed by operation or biopsy, Other ten non-malignant diseases, including brain infarction, post-radiotherapy necrosis or scar and lung abscesses were followed with CT or MRI at least 6 months. All patients received intravenous administration of 18 F-FDG 10-15 mCi, followed by a 40 minutes uptake phase, and subsequent imaged using a Siemens ECAT 931 whole-body scanner with resolution of 4 mm FWHM in the center of the field of view. Filtered back projection reconstruction was used to display attenuated or non-attenuated corrected images. The result of 18 F-FDG PET was retrospectively evaluated to assess the degree of uptake of 18 F-FDG PET in the tumor tissues and compared with CT, MRI and pathology. CT and MRI exam were taken before or after PET study in two weeks. 18 F-FDG PET scans showed a significantly increased FDG metabolism in 47 malignant lesions, The tumor / normal tissue FDG uptake rate were 4.16 ±2.11. In 47 cases with neoplasm, 18 F-FDG PET findings were constant with or further confirmed the CT or MRI diagnosis in 35/47 (74.5%) and 12/47 (253%) cases. Another one small intracranial metastasis ( 18 F-FDG PET imaging in oncology has demonstrated powerful advantage in characterizing tumor lesions, differentiating recurrent disease from treatment effects, staging tumors, evaluating the extent of disease, and monitoring therapy. But 18 F-FDG PET still cant replace CT or MRI in malignance diagnosis. It will be used to approach and hopefully answer the difficult diagnosis

  5. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    International Nuclear Information System (INIS)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  6. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Silva Monteiro

    2017-10-01

    Full Text Available Abstract Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs in systemic granulomatous infections in comparison with gallium-67 (67Ga citrate scintigraphy. Materials and Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99mTc-EDDA-HYNIC-TOC, and 21 after injection of 111In-DTPA-octreotide. All patients also underwent 67Ga citrate imaging, except for one patient who died before the 67Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67Ga uptake in 11 of the 20 patients with positive images and similar to 67Ga uptake in the other 9 patients. The only patient who did not undergo 67Ga scintigraphy underwent 99mTc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99mTc-EDDA-HYNIC-TOC or 111In-DTPA-octreotide seems to be a good alternative to 67Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  7. The Value of Calcium-scoring CT for Ischemic Cardiovascular Disease Screening

    International Nuclear Information System (INIS)

    Oh, Jung Hoan; An, Sung Min

    2009-01-01

    The cardiovascular disease has been known as a common cause of death for a long time in the west. The eating habits of Asia, including Korea, have changed recently, so that this disease is also a problem in Asia now. Annual Report on the Cause of Death Statistics from 1996 to 2006 reported that the cardiovascular disease would become the number one cause of death in the next years. Therefore we realize that more accurate examination is required. The aim of this study was to investigate the accuracy of Calcium-scoring CT and the relationship between risk factor and quantitative scores of Calcium-scoring CT. Through this study we expect that the national public health will be improved. Seventy patients with chest pain were chosen at random. The patients were undergone both coronary CT antigraphy and Calcium - scoring CT at G hospital in Incheon from February 1 to June 30, 2008. The result of the Calcium-scoring CT showed its usefulness for Ischemic cardiovascular disease, with an accuracy similar to that of exercise/pharmacologic stress or ECG when it is difficult for a patient to exercise due to joint problems, aging or for other reasons.

  8. Evaluation of Marfan syndrome: MR imaging versus CT

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fishman, E.K.; Pyeritz, R.E.; Gott, V.L.; Zerhouni, E.A.

    1986-01-01

    Twenty-five patients with Marfan, syndrome underwent both CT and MR imaging. MR imaging were interpreted in blinded fashion and then compared with CT scans MR imaging was found to be equivalent to CT in the detection of aortic, dural, and hip abnormalities in patients not operated on. MR imaging was superior to CT in the evaluation of postoperative patients because the artifact produced by Bjork-Shirley or St. Jude valves precludes adequate evaluation of the aortic root on CT while producing only a small inferior field distortion (a ''pseudo-ventricular septal defect'') on MR imaging. The absence of radiation exposure is another major advantage of MR imaging in this relatively young population requiring serial studies. The authors conclude that MR imaging is the modality of choice for the evaluation and follow-up of patients with Marfan syndrome and offers an appropriate means of screening their kindred

  9. The role of 18FDG, 18FDOPA PET/CT and 99mTc bone scintigraphy imaging in Erdheim–Chester disease

    Energy Technology Data Exchange (ETDEWEB)

    García-Gómez, F.J., E-mail: javier191185@gmail.com [Department of Nuclear Medicine, Virgen del Rocío Universitary Hospital, Seville (Spain); Acevedo-Báñez, I.; Martínez-Castillo, R.; Tirado-Hospital, J.L.; Cuenca-Cuenca, J.I.; Pachón-Garrudo, V.M.; Álvarez-Pérez, R.M.; García-Jiménez, R. [Department of Nuclear Medicine, Virgen del Rocío Universitary Hospital, Seville (Spain); Rivas-Infante, E. [Department of Pathology, Virgen del Rocío Universitary Hospital, Seville (Spain); García-Morillo, J.S. [Department of Internal Medicine, Virgen del Rocío Universitary Hospital, Seville (Spain); Borrego-Dorado, I. [Department of Nuclear Medicine, Virgen del Rocío Universitary Hospital, Seville (Spain)

    2015-08-15

    Highlights: • Erdheim–Chester disease (ECD) is a rare non-Langerhans cell histiocitosis, characterized by multisystemic xanthogranulomatous infiltration by foamy histiocytes. Etiology and pathogenesis are still unknown and only about 500 cases are related in the literature. • Multifocal nature of involvement in ECD can produce a wide variety of clinical signs. In our experience, neurological involvement is associated with mortality in all cases. Characteristic long bone osteosclerosis was a quasi-pathognomonic finding in bone scintigraphy. • To the best of our knowledge, the 18FDOPA-PET/CT not seem useful in the initial staging of ECD based on a single case report. • Bone scintigraphy and the 18FDG-PET/CT that were particularly useful in despite systemic involvement, locate the optimum site for biopsy and treatment response evaluation. In this context, a baseline 18FDG-PET/CT with an optional bone scintigraphy may help in monitoring the disease and could be considered when patients were incidentally diagnosed and periodically follow-up 18FDG-PET/CT must be performed in the follow up to evaluate the treatment response. - Abstract: Erdheim–Chester disease (ECD) is a rare non-Langerhans cell histiocitosis, characterized by multisystemic xanthogranulomatous infiltration by foamy histiocytes that stain positively for CD68 marker but not express CD1a and S100 proteins. Etiology and pathogenesis are still unknown and only about 500 cases are related in the literature. Multisystemic involvement leads to a wide variety of clinical manifestations that results in a poor prognosis although recent advances in treatment. We present the clinical, nuclear medicine findings and therapeutic aspects of a serie of 6 patients with histopathological diagnosis of ECD, who have undergone both bone scintigraphy (BS) and 18F-fluorodeoxyglucose (18FDG)-PET/CT scans in our institution. A complementary 18F-fluorodopa (18FDOPA)-PET/CT was performed in one case. Three different

  10. The role of 18FDG, 18FDOPA PET/CT and 99mTc bone scintigraphy imaging in Erdheim–Chester disease

    International Nuclear Information System (INIS)

    García-Gómez, F.J.; Acevedo-Báñez, I.; Martínez-Castillo, R.; Tirado-Hospital, J.L.; Cuenca-Cuenca, J.I.; Pachón-Garrudo, V.M.; Álvarez-Pérez, R.M.; García-Jiménez, R.; Rivas-Infante, E.; García-Morillo, J.S.; Borrego-Dorado, I.

    2015-01-01

    Highlights: • Erdheim–Chester disease (ECD) is a rare non-Langerhans cell histiocitosis, characterized by multisystemic xanthogranulomatous infiltration by foamy histiocytes. Etiology and pathogenesis are still unknown and only about 500 cases are related in the literature. • Multifocal nature of involvement in ECD can produce a wide variety of clinical signs. In our experience, neurological involvement is associated with mortality in all cases. Characteristic long bone osteosclerosis was a quasi-pathognomonic finding in bone scintigraphy. • To the best of our knowledge, the 18FDOPA-PET/CT not seem useful in the initial staging of ECD based on a single case report. • Bone scintigraphy and the 18FDG-PET/CT that were particularly useful in despite systemic involvement, locate the optimum site for biopsy and treatment response evaluation. In this context, a baseline 18FDG-PET/CT with an optional bone scintigraphy may help in monitoring the disease and could be considered when patients were incidentally diagnosed and periodically follow-up 18FDG-PET/CT must be performed in the follow up to evaluate the treatment response. - Abstract: Erdheim–Chester disease (ECD) is a rare non-Langerhans cell histiocitosis, characterized by multisystemic xanthogranulomatous infiltration by foamy histiocytes that stain positively for CD68 marker but not express CD1a and S100 proteins. Etiology and pathogenesis are still unknown and only about 500 cases are related in the literature. Multisystemic involvement leads to a wide variety of clinical manifestations that results in a poor prognosis although recent advances in treatment. We present the clinical, nuclear medicine findings and therapeutic aspects of a serie of 6 patients with histopathological diagnosis of ECD, who have undergone both bone scintigraphy (BS) and 18F-fluorodeoxyglucose (18FDG)-PET/CT scans in our institution. A complementary 18F-fluorodopa (18FDOPA)-PET/CT was performed in one case. Three different

  11. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  12. Role of 18F-FDG PET/CT in Posttreatment Evaluation of Anal Carcinoma.

    Science.gov (United States)

    Houard, Clémence; Pinaquy, Jean-Baptiste; Mesguich, Charles; Henriques de Figueiredo, Bénédicte; Cazeau, Anne-Laure; Allard, Jean-Baptiste; Laharie, Hortense; Bordenave, Laurence; Fernandez, Philippe; Vendrely, Véronique

    2017-09-01

    The aim of this study was to evaluate the relevance of PET/CT and 18 F-FDG as a strategy for response evaluation after chemoradiotherapy for anal cancer. For this, the performance of posttreatment 18 F-FDG PET/CT, the impact on patient care, and the predictive value of metabolic response were assessed. Methods: This was a retrospective and multicenter analysis of 87 patients treated by chemoradiotherapy for anal squamous cell carcinoma between October 2007 and October 2013. All patients underwent systematic posttreatment 18 F-FDG PET/CT and were followed with at least a clinical examination every 4 mo for 2 y and every 6 mo thereafter. Disease progression was confirmed by biopsy for all patients in the case of local recurrence before surgery. Kaplan-Meier and Cox regression models were used to test for associations between metabolic or clinical endpoints and progression-free survival (PFS) or cause-specific survival (CSS). Results: The median follow-up was 25 mo. 18 F-FDG PET/CT was performed 1-8 mo (median, 4 mo) after completion of chemoradiotherapy. Overall, 25 patients relapsed and 13 died. The posttherapy 18 F-FDG PET/CT did not show any abnormal 18 F-FDG uptake (complete metabolic response [CMR]) in 55 patients whereas 32 displayed incomplete response (non-CMR): 15 patients with partial response and 17 with disease progression. The sensitivity of 18 F-FDG PET/CT to detect residual tumor tissue was 92% (95% confidence interval [CI], 75%-97%), specificity was 85% (95% CI, 75%-92%), positive predictive value was 72% (95% CI, 61%-90%), and negative predictive value was 96.4% (95% CI, 90%-98.7%). The 2-y PFS was 96% (95% CI, 90-100) for patients with CMR and 28% (95% CI, 14-47) for non-CMR patients ( P PET/CT changed patient management in 14 cases (16%), with relevant modifications in 12 (14%). A Cox proportional hazards model of survival outcome indicated that a CMR was the only significant predictor of PFS and CSS ( P PET/CT shows good accuracy in posttreatment

  13. Accuracy of CT enterography and magnetic resonance enterography imaging to detect lesions preoperatively in patients undergoing surgery for Crohn's disease.

    Science.gov (United States)

    Seastedt, Kenneth P; Trencheva, Koiana; Michelassi, Fabrizio; Alsaleh, Doaa; Milsom, Jeffrey W; Sonoda, Toyooki; Lee, Sang W; Nandakumar, Govind

    2014-12-01

    CT enterography and magnetic resonance enterography have emerged as first-line imaging technologies for the evaluation of the gastrointestinal tract in Crohn's disease. The purpose of this work was to evaluate the accuracy of these imaging modalities to identify Crohn's disease lesions preoperatively. This was a retrospective chart review. The study was conducted at a single institution. Seventy-six patients with Crohn's disease with preoperative CT enterography and/or magnetic resonance enterography were included in the study. The number of stenoses, fistulas, and abscesses on CT enterography and/or magnetic resonance enterography before surgery were compared with operative findings. Forty patients (53%) were women, 46 (60%) underwent surgery for recurrent Crohn's disease, and 46 (57%) had previous abdominal surgery. Thirty-six (47%) had a preoperative CT enterography and 43 (57%) had a preoperative magnetic resonance enterography. CT enterography sensitivity was 75% for stenosis and 50% for fistula. MRE sensitivity was 68% for stenosis and 60% for fistula. The negative predictive values of CT enterography and magnetic resonance enterography for stenosis were very low (54% and 65%) and were 85% and 81% for fistula. CT enterography had 76% accuracy for stenosis and 79% for fistula; magnetic resonance enterography had 78% accuracy for stenosis and 85% for fistula. Both were accurate for abscess. False-negative rates for CT enterography were 50% for fistula and 25% for stenosis. False-negative rates for magnetic resonance enterography were 40% for fistula and 32% for stenosis. Unexpected intraoperative findings led to modification of the planned surgical procedure in 20 patients (26%). This study was limited by its small sample size, its retrospective nature, and that some studies were performed at outside institutions. CT enterography and magnetic resonance enterography in patients with Crohn's disease were accurate for the identification of abscesses but not for

  14. Assessment of colonic disease by multi-slice CT pneumocolon after incomplete colonoscopy

    International Nuclear Information System (INIS)

    Zhao Zehua; Liu Wenjin; Xu Songsen; Wang Kang; Wang Weizhong

    2004-01-01

    Objective: To evaluate the use of preoperative MSCT in patients with clinically suspected colorectal disease after incomplete colonoscopy. Methods: After incomplete colonoscopy, 31 patients underwent MSCT before and after intravenous injection of iodinated contrast agent. CT virtual colonography (CTVC), multiplanar reformation (MPR), shaded surface display (SSD), and Raysum images were obtained by using 4 different software in workstation. The results of MSCT were compared with the findings of colonoscopy, intraoperative colon palpation, and postoperative pathology. Results: After incomplete colonoscopy, MSCT was successfully performed in all 31 cases. Postoperative pathology revealed 22 colorectal cancers (one synchronous cancers, two with polyps) and 9 benign disease. 22 colonic carcinomas were all correctly diagnosed by MSCT (including synchronous disease), 2 benign diseases were misdiagnosed as malignancy, and one polyp was missed. Conclusion: MSCT is a feasible and useful method for evaluating the entire colon before surgery in patients with occlusive disease. (author)

  15. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  16. Spiral CT in kidney: assumption of renal function by objective evaluation of renal cortical enhancement

    International Nuclear Information System (INIS)

    Choi, Bo Yoon; Lee, Jong Seok; Lee, Joon Woo; Myung, Jae Sung; Sim, Jung Suk; Seong, Chang Kyu; Kim, Seung Hyup; Choi, Guk Myeong; Chi, Seong Whi

    2000-01-01

    To correlate the degree of renal cortical enhancement, objectively evaluated by means of spiral CT with the serum level of creatinine, and to determine the extent to which this degree of enhancement may be used to detect renal parenchymal disease. Eighty patients (M:F = 50:30; age + 25-19, (mean 53) years) with available serum level of creatinine who underwent spiral CT between September and October 1999 were included in this study. In fifty patients the findings suggested hepatic or biliary diseases such as hepatoma, biliary cancer, or stone, while in thirty, renal diseases such as cyst, hematoma, or stone appeared to be present. Spiral CT imaging of the cortical phase was obtained at 30-40 seconds after the injection of 120 ml of non-ionic media at a rate of 3 ml/sec. The degree of renal cortical enhancement was calculated by dividing the CT attenuation number of renal cortex at the level of the renal hilum by the CT attenuation number of aorta at the same level. The degree of renal cortical enhancement was compared with the serum level of creatinine, and the degree of renal cortical enhancement in renal parenchymal disease with that of the normal group. Among eighty patients there were five with renal parenchymal disease and 75 with normal renal function. The ratio of the CT attenuation number of renal cortex to that of aorta at the level of the renal hilum ranged between 0.49 and 0.99 (mean, 0.79; standard deviation, 0.15). while the serum level of creatinine ranged between 0.6 and 3.2 mg/dl. There was significant correlation (coefficient of -0.346) and a statistically significant probability of 0.002 between the ratio of the CT attenuation numbers and the serum level of creatinine. There was a significant difference (statistically significant probability of less than 0.01) between those with renal parenchymal disease and the normal group. The use of spiral CT to measure the degree of renal cortical enhancement provides not only an effective index for

  17. CT characteristics of thoracoabdominal localized Castleman disease

    International Nuclear Information System (INIS)

    Wang Rengui; Huo Meng; Wang Dandan

    2010-01-01

    Objective: To assess the CT characteristics of thoracoabdominal localized Castleman disease (LCD) in 55 cases and correlate with histopathologic features. Methods: Fifty-five patients with LCD proved histopathologically in thorax (n=25) and abdomen (n=30) were collected during past 20 years. The unenhanced and contrast-enhanced CT were performed in all patients. Two radiologists reviewed CT images and the CT findings were analyzed simultaneously. Results: In 54 patients with hyaline-vascular type (n=50) and mixed type (n=4) localized CD, the lesion typically presented as solitary mass (90.7%, 49 cases), with irregular or lobular or infiltrative margin (83.3%, 45 cases), central calcification (38.9%, 21 cases), marked enhancement (100%, 54 cases), focal non-necrosis low attenuation areas (72.2%, 39 cases), lymphadenopathy (70.4%, 38 cases) and dilated feeding vessels adjacent to the mass (96.3%, 52 cases). One lesion with plasma cell type localized CD presented as a mass with irregular margin, mild enhancement and central necrosis, Four morphologic patterns were classified on CT, including solitary mass with well-circumscribed margin (n=4), irregular or lobular margin (n=30), infiltrative or halo-like margin (n=16), and multiple coalescent masses (n=5). Conclusion: CT features of thoracoabdominal localized CD are closely related to the location and pathological type. LCD with hyaline-vascular and mixed type has typical CT characteristics, while LCD with plasma cell type has no typical CT findings. (authors)

  18. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    Energy Technology Data Exchange (ETDEWEB)

    Du, Louise Y [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Umoh, Joseph [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Nikolov, Hristo N [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Pollmann, Steven I [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Lee, Ting-Yim [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Holdsworth, David W [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada)

    2007-12-07

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 {mu}m, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm{sup -1} and noise of {+-}35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.

  19. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    International Nuclear Information System (INIS)

    Du, Louise Y; Umoh, Joseph; Nikolov, Hristo N; Pollmann, Steven I; Lee, Ting-Yim; Holdsworth, David W

    2007-01-01

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 μm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm -1 and noise of ±35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy

  20. Pulmonary aspergillosis in immunocompetent patients without air-meniscus sign and underlying lung disease: CT findings and histopathologic features

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Soon Ho; Park, Chang Min; Goo, Jin Mo; Lee, Hyun Ju (Dept. of Radiology and Institute of Radiation Medicine, Seoul National Univ. Hospital, Seoul (Korea, Republic of)), email: rosaceci@radiol.snu.ac.kr

    2011-09-15

    Background: Pulmonary aspergillosis in immunocompetent patients has been described as a saprophytic infection with pre-existing lung lesions showing an air-meniscus sign on chest radiograph or CT scans. There have been rare articles dealing with pulmonary aspergillosis in immunocompetent patients without pre-existing lung lesions. Purpose: To evaluate the CT findings of pulmonary aspergillosis in immunocompetent patients without air-meniscus and underlying lung disease and to correlate the CT findings and pathologic features of pulmonary aspergillosis in these patients. Material and Methods: A total of seven surgically proven pulmonary aspergillosis found in immunocompetent patients without an air-meniscus and underlying lung disease (M:F = 1:6; mean age 63.4 years) were included. On CT, the lesion shape, margin, type, location, diameter, presence of satellite nodules, presence of CT halo sign or hypodense sign, and interval growth were evaluated. Histopathologic features of each lesion were classified as one of the following; primary aspergilloma, chronic necrotizing pulmonary aspergillosis, or invasive pulmonary aspergillosis. Correlation between CT findings and pathological features was performed. Results: All lesions presented as a nodule or mass unable to differentiate from malignancy. Most lesions had well-defined margins (n = 4), appeared as solid lesions (n = 7), and were located in the upper lobe (n = 5). Mean diameter of lesions was 2.3 cm. Satellite nodules (n = 2), CT halo sign (n = 1), and hypodense sign (n = 4) were found. Only one lesion increased in size during follow-up. Lesions were pathologically classified as primary aspergilloma (n = 3) and chronic necrotizing pulmonary aspergillosis (n = 4). The hypodense sign on CT was pathologically proved as dense fungal hyphae filled in bronchus and CT halo sign as parenchymal hemorrhage. Conclusion: Pulmonary aspergillosis predominantly presented as a nodule or mass mimicking malignancy in the upper lobes

  1. Pulmonary aspergillosis in immunocompetent patients without air-meniscus sign and underlying lung disease: CT findings and histopathologic features

    International Nuclear Information System (INIS)

    Yoon, Soon Ho; Park, Chang Min; Goo, Jin Mo; Lee, Hyun Ju

    2011-01-01

    Background: Pulmonary aspergillosis in immunocompetent patients has been described as a saprophytic infection with pre-existing lung lesions showing an air-meniscus sign on chest radiograph or CT scans. There have been rare articles dealing with pulmonary aspergillosis in immunocompetent patients without pre-existing lung lesions. Purpose: To evaluate the CT findings of pulmonary aspergillosis in immunocompetent patients without air-meniscus and underlying lung disease and to correlate the CT findings and pathologic features of pulmonary aspergillosis in these patients. Material and Methods: A total of seven surgically proven pulmonary aspergillosis found in immunocompetent patients without an air-meniscus and underlying lung disease (M:F = 1:6; mean age 63.4 years) were included. On CT, the lesion shape, margin, type, location, diameter, presence of satellite nodules, presence of CT halo sign or hypodense sign, and interval growth were evaluated. Histopathologic features of each lesion were classified as one of the following; primary aspergilloma, chronic necrotizing pulmonary aspergillosis, or invasive pulmonary aspergillosis. Correlation between CT findings and pathological features was performed. Results: All lesions presented as a nodule or mass unable to differentiate from malignancy. Most lesions had well-defined margins (n = 4), appeared as solid lesions (n = 7), and were located in the upper lobe (n = 5). Mean diameter of lesions was 2.3 cm. Satellite nodules (n = 2), CT halo sign (n = 1), and hypodense sign (n = 4) were found. Only one lesion increased in size during follow-up. Lesions were pathologically classified as primary aspergilloma (n = 3) and chronic necrotizing pulmonary aspergillosis (n = 4). The hypodense sign on CT was pathologically proved as dense fungal hyphae filled in bronchus and CT halo sign as parenchymal hemorrhage. Conclusion: Pulmonary aspergillosis predominantly presented as a nodule or mass mimicking malignancy in the upper lobes

  2. CT EVALUATION OF AZYGOESOPHAGEAL RECESS IN ADULTS

    Directory of Open Access Journals (Sweden)

    Kulamani Sahoo

    2015-02-01

    Full Text Available Azygoesophageal recess (AER is right posterior mediastinal recess . Knowledge of normal radiologic appearance and manifestations of disease in AER can facilitate the detection and diagnosis of many intrathoracic diseases ranging from infective processes to tumors involving mediastinum, lung/pleura, lymphatic system, upper gastrointestinal system (esophagus & stomach & cardio - vascular system. Aim of this study was to investigate various intrathoracic pathologies, altering the configuration of AER on CT in adults & to find out any significance with various disease processes. This study was carried out in CT center, Department of Radiodiagnosis, Krishna Institute of medical sciences, Karad from October 2012 - September 2014. CT thorax of 156 patients was studied for configuration of AER irrespective of pathology. In this study , configuration of AER was altered in descending order with pathologies belonging to following systems: Respiratory system (Lung parenchyma pathologies causing volume loss of right lower lobe particularly Koch’s , UIP , Malignancy , Pleural pathologies (Secondary more common than Primary >Lymphatic system(secondary subcarinal lymph node more common than Primary Lymphoma >Cardio - vascular system(Cardiomegaly particularly Left atrial enlargement >Gastrointestinal system ( hiatus herni a & esophageal Cancer > Mediastinum ( Koch’s of dorsal spine with paraspinal abscess.

  3. Prospective evaluation of 68Ga-DOTANOC PET-CT in differentiated thyroid cancer patients with raised thyroglobulin and negative 131I-whole body scan: comparison with 18F-FDG PET-CT

    International Nuclear Information System (INIS)

    Kundu, Parveen; Lata, Sneh; Sharma, Punit; Singh, Harmandeep; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    The purpose of the study was to evaluate the role of 68 Ga-DOTANOC PET-CT in differentiated thyroid cancer (DTC) patients with negative 131 I-whole body scan (WBS) along with serially increasing serum thyroglobulin (Tg), and compare the same with 18 F-FDG PET-CT. Sixty two DTC patients with serially rising Tg levels and negative 131 I-WBS were prospectively enrolled. All patients underwent 68 Ga-DOTANOC PET-CT and 18 F-FDG PET-CT within an interval of two weeks. PET-CT analysis was done on a per-patient basis, location wise and lesion wise. All PET-CT lesions were divided into four categories-local, nodal, pulmonary and skeletal. Histopathology and/or serial serum Tg level, clinical and imaging follow up (minimum-1 year) were used as a reference standard. Ga-DOTANOC PET-CT demonstrated disease in 40/62 (65 %) patients and 18 F-FDG PET-CT in 45/62 (72 %) patients, with no significant difference on McNemar analysis (p = 0.226). Per-patient sensitivity and specificity of 68 Ga-DOTANOC PET-CT was 78.4 %, 100 %, and for 18 F-FDG PET-CT was 86.3 %, 90.9 %, respectively. Out of 186 lesions detected by both PET-CTs, 121/186 (65 %) lesions were seen on 68 Ga-DOTANOC PET-CT and 168/186 (90.3 %) lesions on 18 F-FDG PET-CT (p 68 Ga-DOTANOC PET-CT and 18 F-FDG PET-CT for detection of local disease (k = 0.92), while moderate agreement was noted for nodal and pulmonary disease (k = 0.67). 68 Ga-DOTANOC PET-CT changed management in 21/62 (34 %) patients and 18 F-FDG PET-CT in 17/62 (27 %) patients. Ga-DOTANOC PET-CT is inferior to 18 F-FDG PET-CT on lesion based but not on patient based analysis for detection of recurrent/residual disease in DTC patients with negative WBS scan and elevated serum Tg levels. It can also help in selection of potential candidates for peptide receptor radionuclide therapy. (orig.)

  4. Evaluation of living liver donors using contrast enhanced multidetector CT – The radiologists impact on donor selection

    International Nuclear Information System (INIS)

    Ringe, Kristina Imeen; Ringe, Bastian Paul; Falck, Christian von; Shin, Hoen-oh; Becker, Thomas; Pfister, Eva-Doreen; Wacker, Frank; Ringe, Burckhardt

    2012-01-01

    Living donor liver transplantation (LDLT) is a valuable and legitimate treatment for patients with end-stage liver disease. Computed tomography (CT) has proven to be an important tool in the process of donor evaluation. The purpose of this study was to evaluate the significance of CT in the donor selection process. Between May 1999 and October 2010 170 candidate donors underwent biphasic CT. We retrospectively reviewed the results of the CT and liver volumetry, and assessed reasons for rejection. 89 candidates underwent partial liver resection (52.4%). Based on the results of liver CT and volumetry 22 candidates were excluded as donors (31% of the cases). Reasons included fatty liver (n = 9), vascular anatomical variants (n = 4), incidental finding of hemangioma and focal nodular hyperplasia (n = 1) and small (n = 5) or large for size (n = 5) graft volume. CT based imaging of the liver in combination with dedicated software plays a key role in the process of evaluation of candidates for LDLT. It may account for up to 1/3 of the contraindications for LDLT

  5. Proton MRI in the evaluation of pulmonary sarcoidosis: Comparison to chest CT

    International Nuclear Information System (INIS)

    Chung, Jonathan H.; Little, Brent P.; Forssen, Anna V.; Yong, Jin; Nambu, Atsushi; Kazlouski, Demitry; Puderbach, Michael; Biederer, Juergen; Lynch, David A.

    2013-01-01

    Purpose: The purpose of this study was to determine the feasibility of proton MRI of the lung in sarcoidosis patients and the agreement between the imaging appearance of pulmonary sarcoidosis on MRI and CT. Materials and methods: Chest CT scans and dedicated pulmonary MRI scans (including HASTE, VIBE, and TrueFISP sequences) were performed within 90 days of each other in 29 patients. The scans were scored for gross parenchymal opacification, reticulation, nodules, and masses using a 3-point lobar scale. Total and subset scores for corresponding MRI and CT scans were compared using the Spearman correlation test, Bland–Altman plots, and Cohen's quadratic-weighted kappa analysis. MRI scores were compared to CT by lobe and disease category, using percentage agreement, Spearman rank correlation, and Cohen's quadratic-weighted kappa. Results: The mean (±s.d.) time between MRI and CT scans was 33 ± 32 days. There was substantial correlation and agreement between total disease scoring on MRI and CT with a Spearman correlation coefficient of 0.774 (p < 0.0001) and a Cohen's weighted kappa score of 0.646. Correlation and agreement were highest for gross parenchymal opacification (0.695, 0.528) and reticulation (0.609, 0.445), and lowest in the setting of nodules (0.501, 0.305). Agreement testing was not performed for mass scores due to low prevalence. Upper lobe scoring on MRI and CT demonstrated greater agreement compared to the lower lobes (average difference in Cohen's weighted kappa score of 0.112). Conclusion: There is substantial correlation and agreement between MRI and CT in the scoring of pulmonary sarcoidosis, though MRI evaluation in the upper lobes may be more accurate than in the lower lobes

  6. Role of X-ray CT in the evaluation of extension of ovarian cancer

    International Nuclear Information System (INIS)

    Saito, Takashi

    1991-01-01

    To evaluate the utility of X-ray computed tomography (CT) in the management of malignant ovarian tumor, preoperative CT of 89 patients with ovarian cancer were analyzed on the basis of their surgically confirmed findings. Relationships between CT findings and clinical factors such as actual tumor spread, stage, and accomplished surgery were studied. The results obtained were as follows. The rates of correct diagnosis in tumor spread were 79.8% for tumor growth on the external surface of the ovary, 77.6% for involvement of both ovaries, 79.8% for ascites, 78.2% for metastasis to the uterus, 68.2% for peritoneal metastasis, 77.0% for metastasis to the intestine, and 79.3% for the metastasis to the omentum. Comparing the stage suggested by CT (CT stage) and the stage revealed by surgery (surgical stage), the stages coincided in 57 patients (64.0%). CT stages were overestimated in 9 caces and underestimated in 23 caces. As for the practicability of surgery, either complete or standard operation was performed in 31 of 33 caces (93.9%) of CT stage I, 21 of 28 (75.0%) of CT stage II, and 11 of 28 (39.3%) of CT stage III. The possibility of accomplishing surgery was very low when CT indicated stage III disease. (author)

  7. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  8. The evaluation of atherosclerosis in coronary arteries with CT values

    International Nuclear Information System (INIS)

    Takemoto, Akiko

    1990-01-01

    In 50 patients with ischemic heart disease, X-ray computed tomography (CT) and coronary arteriography (CAG) were performed to compare CT values and CAG-proven stenosis in the left main trunk, left anterior descending, left circumflex, and right coronary artery. Luminal stenosis was graded as normal (no stenosis), minimal (between normal and significant), and significant (more than 50% in the left main trunk; more than 75% in the other arteries). CT values were significantly correlated with coronary artery stenosis; -5.4 in the normal group (71 arteries), +5.0 in the minimal group (63 arteries), and +31.8 in the significant group (51 arteries). In the normal group, CT values were independent of aging; -4.9 for patients younger than 50 years, -8.0 for those aged 50 to 59 years, and -0.4 for those more than 60 years. Increased CT values were associated with severer coronary artery disease shown on CAG. In determining significant coronary artery stenosis, CT values of more than 35 had a positive predictive value of 73.3%, a sensitivity of 43.1%, a specificity of 94.0%, an accuracy of 80.0%, and a likelihood ratio of 7.18. Measurement of CT values for the coronary arteries seems to be a noninvasive method for predicting significant stenosis. For patients younger than 60 years, high CT values even in a single artery seem to be associated with a high likelihood of significant stenosis and multivessel disease. (N.K.)

  9. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  10. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Ciet, Pierluigi [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands); Serra, Goffredo; Catalano, Carlo [University of Rome ' ' Sapienza' ' , Radiology, Rome (Italy); Bertolo, Silvia; Morana, Giovanni [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Spronk, Sandra [Erasmus MC, Radiology, Rotterdam (Netherlands); Erasmus MC, Epidemiology, Rotterdam (Netherlands); Ros, Mirco [Ca' Foncello Hospital, Pediatrics, Treviso (Italy); Fraioli, Francesco [University College London (UCL), Institute of Nuclear Medicine, London (United Kingdom); Quattrucci, Serena [University of Rome Sapienza, Pediatrics, Rome (Italy); Assael, M.B. [Azienda Ospedaliera di Verona, Verona CF Center, Verona (Italy); Pomerri, Fabio [University of Padova, Department of Medicine-DIMED, Padova (Italy); Tiddens, Harm A.W.M. [Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands)

    2016-03-15

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  11. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    International Nuclear Information System (INIS)

    Ciet, Pierluigi; Serra, Goffredo; Catalano, Carlo; Bertolo, Silvia; Morana, Giovanni; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M.B.; Pomerri, Fabio; Tiddens, Harm A.W.M.

    2016-01-01

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  12. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  13. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  14. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío, E-mail: paulohsm42@gmail.com [Universidade de Campinas (UNICAMP), SP (Brazil). Escola de Medicina; Mengatti Jair [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-11-15

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ({sup 67}Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of {sup 99m}Tc-EDDA-HYNIC-TOC, and 21 after injection of {sup 111}In-DTPA-octreotide. All patients also underwent {sup 67}Ga citrate imaging, except for one patient who died before the {sup 67}Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by {sup 67}Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than {sup 67}Ga uptake in 11 of the 20 patients with positive images and similar to {sup 67}Ga uptake in the other 9 patients. The only patient who did not undergo {sup 67}Ga scintigraphy underwent {sup 99m}Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with {sup 99m}Tc-EDDA-HYNIC-TOC or {sup 111}In-DTPA-octreotide seems to be a good alternative to {sup 67}Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  15. Angio-CT in congenital heart disease and kidney pathology in children, preliminary report

    International Nuclear Information System (INIS)

    Biejat, A.; Zielinski, T.; Tarnowska, A.

    2004-01-01

    Due to recent development in computer tomography technique especially in the field of spiral CT, additional computer programming support for 3D reconstruction and automatic contrast media syringe systems, CT is a useful diagnostic tool in pediatric radiology in patients with congenital heart disease and kidneys pathology. Between July 2001 and June 2003 in our CT department 31 angio CT examinations were performed (19 in congenital heart disease and 12 in patients with kidneys pathology). The most important group consists patients after surgical correction of aortic coarctation (CoA)-13 cases. In the kidney pathology group the most common indication for the CT was arterial hypertension - 7 cases. CT examinations were performed using Toshiba ASTEION single - detector system with modified Rogalla et al. protocols. Regular CT scans were complemented with additional multiplane presentations and 3D and MIP reconstructions of the vessels. Original protocols were modified mostly in reduction of contrast media administration (up to 1ml/kg) and pitch increase to 1.2-1.7. Patients with heart disease in contrary to kidney pathology patients were also diagnosed with invasive procedures. In congenital heart disease group recoarctation was diagnosed in angio CT in 7 cases and in 5 cases in angiography. In remaining group CT confirmed angiography results in 3 cases (complex heart anomaly). In 2 cases of anomalous pulmonary venosus return and double aortic arch angiography confirmed CT results. In 7 cases with arterial hypertension Angio-CT revealed: nephrosclerosis in 1 case and IVC thrombosis in another. In remaining 5 cases CT results were normal. Angio-CT in pediatric patients should be performed with automatic syringes proper contrast media administration and physical parameters (mAs, kV) and can limit the indications for invasive procedures. (author)

  16. CT findings of pancreatic disease

    International Nuclear Information System (INIS)

    Lee, Mi Sook; Park, In Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song; Won, Jong Jin

    1988-01-01

    CT was found to be a reliable, often specific, and noninvasive method for detecting pancreatic diseases. In a study of pancreatic lesions, 37 cases having satisfactory operative and histological proofs were analyzed by CT at PMC from Jan. 1986 to Oct. 1987. The results were as following: 1. Male:female is 26:11. 2. The incidence of pancreatic disease were as follows: 1) Pancreatic cancer:21 cases (56%) a.Head:12 cases b.Body:4 cases c.Tail:1 case d.Body and tail:1 case e.Uncinate process:2 cases f.Entire pancreas: 1 case 2) Acute pancreatitis: 6 cases (16%) 3) Chronic pancreatitis:5 cases (14%) 3. The characteristic CT findings: 1) 100% of pancreatic head cancer showed focal mass or alteration of pancreatic head contour and biliary tree dilatation, and 33% (7/12) fat line obliteration. 2) All of other pancreatic cancer except head appeared as focal mass or contour alteration and fat line obliteration. 3) Total 6 cases of acute pancreatitis showed that 5 cases diffuse enlargement of pancreas, 3 fluid collection (2 cases:left anterior pararenal and posterior pararenal space and lesser sac, 1 case:only pancreas body) and 1 case abscess formation. 4) Total 5 cases of chronic pancreatitis revealed diffuse enlargement 2 cases and atrophy 1 case, pancreatic ductal dilatation 3 cases, calcification 2 cases, and biliary tree dilatation with CBD tapering appearance 1 case. 5) All cases of pseudocysts were well marginated cystic lesions that located at head in 3 cases and tail 3 cases, and 4 cases were well defined pure cystic masses but 1 case was well capsulated cyst with multiple internal septation

  17. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  18. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho; Kim, Jong Hyo; Chae, Young Moon; Lee, Yun Hee; Han, Heon

    2006-01-01

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher (ρ = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis

  19. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho [Boramae Munincipal Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Jong Hyo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Chae, Young Moon [Yonsei University Graduate School of Public Heath, Seoul (Korea, Republic of); Lee, Yun Hee [The Graduate School of Imformation, Yonsei, Seoul (Korea, Republic of); Han, Heon [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2006-06-15

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher ({rho} = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis.

  20. CT findings of pleural lesions: differential diagnosis between malignant benign diseases

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seung Yon; Lim, Tae Hwan; Kim, Woo Sun; Park, Kwang Gil [Asan Medical Center, University of Ulsan, College of Medicine, Seoul (Korea, Republic of)

    1991-05-15

    A number of benign and malignant diseases may cause pleural abnormalities. Since the resolution of computed tomography (CT) has been improved, the detailed anatomy of pleura can now be well delineated in various pleural diseases. We reviewed retrospectively the CT findings of 60 patients with pathologically proved pleural diseases in order to find out the differential points between benign and malignant diseases. Thirty-six patients had malignant diseases (20 adenocarcinoma, 8 squamous cell carcinoma, 4 small cell carcinoma, 2 lung metastasis, 1 large cell carcinoma, 1 small and large cell carcinoma), and 24 patients had benign diseases (16 tuberculosis including empyema, 3 bacterial empyema, 3 pneumonia, 1 lung abscess, 1 lung contusion). The CT features that suggested malignant pleural diseases were high-grade mediastinal involvement (57.9%, {rho} < 0.1), thick and irregular thickening with nodularity and mass formations (38.5%, {rho} < 0.1), Circumferential pleural thickening 132.1%, {rho} < 0.01), and aggressive pleural effusion 122.2%, {rho} < 0.05). Benign pleural lesions were typically represented by pleural calcification (50%) and extrapleural fat accumulation (45.8%)

  1. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  2. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  3. Evaluation of CT findings for diagnosis of pleural effusions

    International Nuclear Information System (INIS)

    Arenas-Jimenez, J.; Alonso-Charterina, S.; Fernandez-Latorre, F.; Gil-Sanchez, S.; Sanchez-Paya, J.; Lloret-Llorens, M.

    2000-01-01

    Computed tomography studies are usually used to assess patients with pleural effusions, and radiologists should be aware of the significance of different CT findings for the diagnosis of the effusion. The purpose of this study was to evaluate CT findings for etiological diagnosis of pleural effusions. Contrast-enhanced CT of the chest of 211 patients with pleural effusion of definite diagnosis were evaluated. The CT images were evaluated for the presence and extent of pleural effusion, thickening or nodules, extrapleural fat and other changes in the mediastinum or lung. The CT scans were read by two independent observers and correlation between them was evaluated. Comparison of CT findings between benign and malignant effusions, between exudates and transudates, and between empyemas and the other parapneumonic effusions were carried out. Kappa values for most CT findings were >0.85. Loculation, pleural thickening, pleural nodules, and extrapleural fat of increased density were only present in exudative effusions. Multiple pleural nodules and nodular pleural thickening were the only pleural findings limited to malignant pleural effusions. The signs were also more frequently seen in empyemas than in other parapneumonic effusions. Computed tomography findings can help to distinguish between transudates and exudates. Although there is some overlap between benign and malignant pleural effusions, pleural nodules and nodular pleural thickening were present almost exclusively in the latter. Although differences between CT findings of empyemas and the other parapneumonic effusions exist, there is no finding which can definitely differentiate between them. (orig.)

  4. Comparison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, W.G. Jr.; Waluch, V.; Yadley, R.A.; Wycoff, R.R.

    1984-09-01

    Magnetic resonance imaging (MR) (0.35T) and computed tomography (CT) were compared in 400 consecutive patients with suspected disease of the brain and cervical spinal cord. Of 325 positive diagnoses, MR detected abnormality while CT was normal in 93; MR was more specific in 68; MR and CT gave equivalent information in 129; CT was more specific in 32; and CT was positive while MR was normal in 3. MR was superior to CT in detection of multiple sclerosis, subcortical arteriosclerotic encephalopathy, posterior fossa infarcts and tumors, small extra-axial fluid collections, and cervical syringomyelia. CT was preferable in evaluation of meningiomas and separation of tumor from edema. CT takes less time and may be preferable in patients with acute trauma as well as very young or elderly individuals. Thus the two studies should be considered complementary.

  5. Comparison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord

    International Nuclear Information System (INIS)

    Bradley, W.G. Jr.; Waluch, V.; Yadley, R.A.; Wycoff, R.R.

    1984-01-01

    Magnetic resonance imaging (MR) (0.35T) and computed tomography (CT) were compared in 400 consecutive patients with suspected disease of the brain and cervical spinal cord. Of 325 positive diagnoses, MR detected abnormality while CT was normal in 93; MR was more specific in 68; MR and CT gave equivalent information in 129; CT was more specific in 32; and CT was positive while MR was normal in 3. MR was superior to CT in detection of multiple sclerosis, subcortical arteriosclerotic encephalopathy, posterior fossa infarcts and tumors, small extra-axial fluid collections, and cervical syringomyelia. CT was preferable in evaluation of meningiomas and separation of tumor from edema. CT takes less time and may be preferable in patients with acute trauma as well as very young or elderly individuals. Thus the two studies should be considered complementary

  6. Evolution of overall CT in the staging of patients with Hodgkin's disease

    International Nuclear Information System (INIS)

    Maurizi Enrici, R.; Capua, A.; Osti, M.F.; Sarra, R.; Tombolini, V.; Anselmo, A.P.; Campodonico, F.

    1991-01-01

    From 1983 through 1989, 141 untreated patients with Hodgkin's disease underwent CT of the abdomen. They subsequently underwent staging laparotomy plus splenectomy and multiple biopsies of liver and lymph nodes, at the Institute of Radiology and Hematology, University 'La Sapienza', Rome. CT results were compared with surgical findings to evaluate CT sensitivity, specificity, and overall accuracy. The cases from this series were divided into two groups depending on the characteristics of the CT scanners employed. From 1983 to 1985, 78 patients were examined with 3nd-generation CT units; from 1986 to 1989, 63 patients underwent CT performed with 3rd-generation scanner. The results from the two groups were analyzed according to these parameters. A total number of 622 biopsies were performed, of spleen, liver and lymph nodes. CT sensitivity, specificity, and overall accuracy were: 22.9% (group I) vs 43.7% (group II), 83.1% vs 92%, and 68.4% vs 81.2% for lymph nodes; 28.1% vs 36.3%, 93.5% vs 98%, and 66.7% vs 87.3% for the spleen, and 12.5% vs 42.8%, 97.1% vs 98.2% and 88.5% vs 92.1% for the liver. Our results demonstrate an obvious increase in reliability with newer units, even though a high percentage of false-negatives were still observed in our series, which caused understaging in 19.4% of cases vs 24.4 in group I

  7. CT features of pulmonary mycobacterial disease in patients with acquired immunodeficiency syndrome

    International Nuclear Information System (INIS)

    Zhu Ying; Zhang Zhiyong; Shi Yuxin; Feng Feng

    2013-01-01

    Objective: To study the CT features of pulmonary non-tuberculous mycobacteria (NTM) disease in patients with acquired immunodeficiency syndrome (AIDS) and explore the different CT appearances between AIDS-NTM and AIDS-TB. Methods: CT findings of pulmonary NTM disease in 27 AIDS patients (NTM group) were retrospectively analyzed and compared with that of tuberculosis in 30 AIDS patients (TB group). The results were statistically analyzed using Fisher's exact test. Results: CT findings of NTM appeared significantly more than that of TB as follows: high-density nodules (n = 18 vs 1, P < 0.01), ground-glass opacities (n = 10 vs 0, P < 0.01), fibrotic band (n = 17 vs 3, P < 0.01), bronchiectasis (9 vs 2, P = 0.012). CT findings of NTM appeared significantly less than that of TB as follows: miliary nodules (0 vs 6, P = 0.016), air space consolidations (n = 2 vs 11, P < 0.01), pleural effusion (n = 1 vs 9, P < 0.01). Conclusion: Nodule and fibrotic band accompanied with bronchiectasis were the main CT manifestations of pulmonary NTM disease in AIDS patients, while air space consolidation accompanied with pleural effusion and miliary nodules were the predominate CT findings of pulmonary tuberculosis in AIDS patients. (authors)

  8. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  9. Preoperative CT evaluation of adenocarcinoma of the gastroesophageal junction

    International Nuclear Information System (INIS)

    Bennett, J.D.; Lefcoe, M.S.; Finley, R.; Yoshi, C.; Inculet, R.

    1988-01-01

    A retrospective review was undertaken of 53 preoperative computed tomographic (CT) scans obtained between March 1983 and April 1988 from patients undergoing surgery for adenocarcinoma of the gastroesophageal junction, and results were correlated with the surgical-pathologic findings. CT was unreliable in predicting aortic, pericardial, or pancreatic invasion (sensitivity, 0/8; specificity, 41/45). Of 45 pathologically positive nodal groups, the largest node measured on CT scans was 10 mm or less in 36 cases. The accuracy of preoperative CT in staging adenocarcinoma of the gastroesophageal junction is limited by its low sensitivity in detecting local invasion. Nodal size as measured with CT is not a reliable indicator of metastatic disease

  10. Veno-occlusive disease of the colon - CT findings

    International Nuclear Information System (INIS)

    Rademaker, J.

    1998-01-01

    Venous occlusion is a rare cause of ischemic bowel disease and is usually brought about by thrombosis that may occur as a complication of systemic disorders like systemic lupus erythematosus, Behcet disease or Churg-Strauss syndrome. This report describes a patient with veno-occlusive disease of the colon caused by lymphocytic phlebitis. Typical CT findings included homogeneous bowel wall thickening and vascular engorgement. (orig.) (orig.)

  11. Evaluation of living liver donors using contrast enhanced multidetector CT – The radiologists impact on donor selection

    Directory of Open Access Journals (Sweden)

    Ringe Kristina

    2012-07-01

    Full Text Available Abstract Background Living donor liver transplantation (LDLT is a valuable and legitimate treatment for patients with end-stage liver disease. Computed tomography (CT has proven to be an important tool in the process of donor evaluation. The purpose of this study was to evaluate the significance of CT in the donor selection process. Methods Between May 1999 and October 2010 170 candidate donors underwent biphasic CT. We retrospectively reviewed the results of the CT and liver volumetry, and assessed reasons for rejection. Results 89 candidates underwent partial liver resection (52.4%. Based on the results of liver CT and volumetry 22 candidates were excluded as donors (31% of the cases. Reasons included fatty liver (n = 9, vascular anatomical variants (n = 4, incidental finding of hemangioma and focal nodular hyperplasia (n = 1 and small (n = 5 or large for size (n = 5 graft volume. Conclusion CT based imaging of the liver in combination with dedicated software plays a key role in the process of evaluation of candidates for LDLT. It may account for up to 1/3 of the contraindications for LDLT.

  12. The muscle CT of thigh in chronic Werdnig-Hoffmann disease

    International Nuclear Information System (INIS)

    Horikawa, Hirosei; Konagaya, Masaaki; Takayanagi, Tetsuya; Otsuji, Hideaki

    1986-01-01

    In this paper, the muscle CT of thigh in chronic Werdnig-Hoffmann disease (chronic WH) was evaluated. The subjects were five cases of chronic WH (3 males and 2 females, ages ranging from 6 to 22 years) and four control males. All cases showed symmetrical muscular weakness. The proximal muscle were more affected than the distal in the upper limbs. But the muscle strength of hip adduction was relatively spared as compared with other strength of lower limbs. The CT scan was carried out at the upper quarter level between lesser trochanter and medial condyle of the femur. The muscle CT of cases aged 6 and 7 years showed the severely decreased cross-sectional area of muscle without significant decrease in density. The atrophic muscles were surrounded by a large amount of low density area. The hamstring muscles and the adductor muscles, especially adductor longus muscle (ALM), were less affected than the quadriceps femoris muscles. Spotty and moth-eaten low density areas were observed dominantly in the severely affected muscles. In the advanced cases, only ALM could be identified on the CT image. The other muscles were unable to be identified because of severe atrophy with extremely low density. These CT findings suggest the process of muscular wastings of chronic WH as follows; at first muscle fibers are atrophied due to denervation and sooner or later replaced with fat tissue. Moreover, the preservation of ALM suggests that loss of anterior horn cells does not always go on homogeneously. (author)

  13. A comparative study between subjective assessment and quantitative evaluation of CT findings with cerebral palsy

    International Nuclear Information System (INIS)

    Sugie, Yoko; Sugie, Hideo; Kitai, Akiko; Maruyama, Hiroshi; Fukuyama, Yukio

    1982-01-01

    Computed tomography (CT) was performed on 200 children with children palsy with Hitachi CT-H250. The CT scans of 136 cases revealed cerebral atrophy with ventricular and/or subarachnoid space enlargement. The lateral ventricles, the third ventricle and the two parts of subarachnoid space on the CT picture were subjectively evaluated and divided into five grades ranging from no enlargement to marked enlargement. In addition, the size of the ventricles and the subarachnoid spaces were quantitatively determined; the transverse diameter of brain (b), the largest width of the anterior horns of the lateral ventricles (c), the bicaudate nuclear distance (d), the greatest width of the third ventricle, the longitudinal cerebral fissure and sylvian fissures as described by Miyao et al. (1978). Comparison of these quantitative techniques confirmed the initial subjective evaluation. However, in some cases, amendment of the subjective evaluation was needed. As mentioned before (Miyao et al.), the cerebral longitudinal fissure was relatively wide in normal infants. Accordingly, it was often difficult to find out abnormal widening only by subjective evaluation. The purpose of this paper was to establish the criteria of quantitative measuring and assessing of the lateral and third ventricles, the cerebral longitudinal fissurem, and the sylvian fissures enlargement. Interpretation of some problem cases associated with measuring was also discussed. The quantitative CT evaluation may be a good reference in assessing cerebral atrophy in cerebral palsy and other neurological diseases. (author)

  14. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  15. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  16. Evaluation of CT in the investigation of patellofemoral malalignment

    International Nuclear Information System (INIS)

    Zhang Quan; Huang Huangyuan; Xia Jun; Chen Wenjun

    1999-01-01

    Objective: To evaluate CT in investigating patellofemoral malalignment. Methods: CT was used to evaluate 32 patients (50 knees) with persistent patellofemoral pain and 15 asymptomatic volunteers (20 knees). Multiple mid-patellar images were obtained at 30 degree flexion. Results: Compared to controls, the patients had marked malalignment including three distinct patterns. 11 knees had lateral patellae based on high congruence angles (CA). 8 knees had tilted patellae with lower lateral patellofemoral angles (LPFA). 10 knees had both high CA and lower LPFA indicating both lateral and tilted patella. Conclusions: CT may be the optimal imaging method of evaluating the patellofemoral joint. An awareness of different patterns of malalignment is a significant advantage of CT when planning selective surgical realignment for these patients

  17. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  18. Assessment of trunk muscle density using CT and its association with degenerative disc and facet joint disease of the lumbar spine.

    Science.gov (United States)

    Sebro, Ronnie; O'Brien, Liam; Torriani, Martin; Bredella, Miriam A

    2016-09-01

    The purpose of this study was (1) to evaluate the association of trunk muscle density assessed by computed tomography (CT) with age, gender, and BMI and (2) to evaluate the association between trunk muscle CT density and degenerative disc and facet joint disease of the lumbar spine. The study was IRB approved and HIPAA compliant. The study group comprised 100 subjects (mean age 44.4 ± 22.2 years, 51 % male) who underwent CT of the abdomen and pelvis without intravenous contrast. Exclusion criteria included prior abdominal or spine surgery, active malignancy and scoliosis. CTs were reviewed and the attenuation of the rectus abdominis, transverse abdominis, internal and external obliques, psoas, multifidus, longissimus and gluteus maximus were measured bilaterally at consistent levels. Degenerative disc and bilateral facet joint disease were scored using established methods. Univariate analyses were performed using linear regression. Multivariate linear regression was performed to adjust for age, gender and BMI. CT density of each trunk muscle correlated inversely with age (p degenerative disc and facet joint disease in the univariate analyses (p degenerative disc and facet joint disease respectively in the multivariate analysis. Fatty infiltration of trunk musculature increases with age and BMI. Fatty infiltration of the gluteus maximus and transverse abdominis are associated with degenerative disc and facet joint disease, independent of age, gender and BMI.

  19. Intraosseous lipomata in Paget's disease: an unusual CT appearance

    International Nuclear Information System (INIS)

    Robbie, M.J.; Pratsis, K.K.; Lockie, D.J.

    1991-01-01

    A case of multiple intraosseous lumbar vertebral lipomata is reported occurring in the prescence of Paget's disease. The pathology and radiology are correlated. An 84 year old man with Paget's disease presented after a cerebrovascular accident which caused him a mild right hemiparesis. Lumbar vertebral lesions were noted incidentally on abdominal radiographs and a CT scan was performed to define the abnormal areas. CT appearance favoured a slow growing non-invasive lesion. However, it failed to show the lower attenuation expected of a fatty lesion such as a lipoma. It is estimated that CT can be diagnostic if it does show fat level attenuation while Magnetic Resonance Imaging can define the lesion in the sagittal and coronal planes as well as provide the signal characteristics of fat (high signal on T1 and T2 weighted images) irrespective of its myxoid ground substance content

  20. ECG gated NMR-CT for cardiovascular diseases

    International Nuclear Information System (INIS)

    Nishikawa, J.; Machida, K.; Iio, M.; Yoshimoto, N.; Sugimoto, T.; Kawaguchi, H.; Mano, H.

    1984-01-01

    The authors applied NMR-CT to cardiac study with ECG gated technique to evaluate the left ventricular (LV) function and compared it with cardiovascular nuclear medicine study (NM). The NMR-CT machine has resistive air-core magnet with 0.15 Tesla. The saturation recovery image or inversion recovery image were obtained as 256 x 256 matrix and 15 mm in thickness. The study population was ten patients who were evaluated both by NMR image and by NM performed within one week interval. The heart muscle was able to be visualized without any contrast material nor radioisotopes in inversion recovery images, whereas saturation recovery images failed to separate heart muscle from blood pool. The wall motions of LV in both methods were well correlated except for inferior wall. The values of ejection fraction in NMR image were moderately low, but two modalities showed satisfactory correlation (r=0.85). The region of myocardial infarction was revealed as wall thinning and/or wall motion abnormality. It is still preliminary to draw a conclusion, however, it can be said that in the evaluation of LV function, method by NMR might be of equal value to those of NM. It can be certain that eventually gated NMR-CT will become more effective method for various aspects of cardiovascular evaluation

  1. Assessment of trunk muscle density using CT and its association with degenerative disc and facet joint disease of the lumbar spine

    International Nuclear Information System (INIS)

    Sebro, Ronnie; O'Brien, Liam; Torriani, Martin; Bredella, Miriam A.

    2016-01-01

    The purpose of this study was (1) to evaluate the association of trunk muscle density assessed by computed tomography (CT) with age, gender, and BMI and (2) to evaluate the association between trunk muscle CT density and degenerative disc and facet joint disease of the lumbar spine. The study was IRB approved and HIPAA compliant. The study group comprised 100 subjects (mean age 44.4 ± 22.2 years, 51 % male) who underwent CT of the abdomen and pelvis without intravenous contrast. Exclusion criteria included prior abdominal or spine surgery, active malignancy and scoliosis. CTs were reviewed and the attenuation of the rectus abdominis, transverse abdominis, internal and external obliques, psoas, multifidus, longissimus and gluteus maximus were measured bilaterally at consistent levels. Degenerative disc and bilateral facet joint disease were scored using established methods. Univariate analyses were performed using linear regression. Multivariate linear regression was performed to adjust for age, gender and BMI. CT density of each trunk muscle correlated inversely with age (p < 0.001) and BMI (p < 0.001). CT density of each trunk muscle correlated inversely with degenerative disc and facet joint disease in the univariate analyses (p < 0.001); however, only the gluteus maximus and the transverse abdominis remained significant predictors of degenerative disc and facet joint disease respectively in the multivariate analysis. Fatty infiltration of trunk musculature increases with age and BMI. Fatty infiltration of the gluteus maximus and transverse abdominis are associated with degenerative disc and facet joint disease, independent of age, gender and BMI. (orig.)

  2. Veno-occlusive disease of the colon - CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Rademaker, J [Department of Radiology I, Medical School Hannover (Germany)

    1998-10-01

    Venous occlusion is a rare cause of ischemic bowel disease and is usually brought about by thrombosis that may occur as a complication of systemic disorders like systemic lupus erythematosus, Behcet disease or Churg-Strauss syndrome. This report describes a patient with veno-occlusive disease of the colon caused by lymphocytic phlebitis. Typical CT findings included homogeneous bowel wall thickening and vascular engorgement. (orig.) (orig.) With 1 fig., 4 refs.

  3. Use of 18F-FDG PET/CT in the preoperative evaluation of patients diagnosed with peritoneal carcinomatosis of ovarian origin, candidates to cytoreduction and hipec. A pending issue

    International Nuclear Information System (INIS)

    Lopez-Lopez, V.; Cascales-Campos, P.A.; Gil, J.; Frutos, L.; Andrade, R.J.; Fuster-Quiñonero, M.; Feliciangeli, E.; Gil, E.; Parrilla, P.

    2016-01-01

    Highlights: • CT showed the better results confirming ovarian peritoneal disease than 18 F-FDG PET/CT. • CT and 18 F-FDG PET/CT present a low detection capability for LSS-3 injury. • Main utility of 18 F-FDG PET/CT is the evaluation of extraperitoneal extension. - Abstract: Purpose: To evaluate the clinical usefulness of the results obtained with 18 F-FDG PET/CT in relation to CT in the preoperative staging of patients with peritoneal carcinomatosis secondary to primary or recurrent ovarian cancer candidates to cytoreductive surgery and hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC). Material and methods: A retrospective study comparing the results obtained with CT and 18 F-FDG PET/CT in the preoperative evaluation of a series of 59 patients was performed. In all patients the peritoneal carcinomatosis index (PCI) was determined by preoperative radiological CT and 18F-FDG PET/CT and compared with surgical PCI, which was considered as reference. Results: Of the 59 patients studied, in 55 peritoneal carcinomatosis presences were confirmed (4 patients had complete responses to neoadjuvant chemotherapy). The mean surgical, CT and 18F-FDG PET/CT PCI was 9.46 ± 7.70, 3.69 ± 3.96 and 2.25 ± 1.02, respectively. In the global disease detection, CT showed a higher positive likelihood ratio (LR+) than 18 F-FDG PET/CT (15.3, 95% CI 8.35–28.04 vs. 3.47, 95% CI 3.36–5.11) and a lower negative likelihood ratio (LR-) than 18F-FDG PET/CT (0.67, 95% CI 0.61–0.73 vs. 0.82, 95% CI 0.76–0.88). In every region of the abdomen the CT showed a greater LR+ than 18F-FDG PET/CT and a lower LR- than 18F-FDG PET/CT. Conclusions: CT showed the best diagnostic results compared to 18 F-FDG PET/CT to confirme the presence of peritoneal disease. The lower performance of the 18 F-FDG PET/CT suggests that the main utility of 18 F-FDG PET/CT is to evaluate a possible metastatic extraperitoneal spread of the disease.

  4. Computed tomography in neoplastic diseases of the skull base and adjacent areas using EMI scanner CT-1000

    International Nuclear Information System (INIS)

    Ono, Yoshimi; Ohtake, Eiji; Asakura, Koichi; Tanohata, Kazunori; Ito, Otomasa

    1980-01-01

    CT-findings of 145 patients with and without neoplastic diseases of the skull base were evaluated using EMI CT-1000. Analysis of 64 patients without any lesion at the skull base showed more artifacts compared with that of higher slices, so that good or fair images were obtained only in 64% of this groups of patients. The most important factor in producing artifacts are considered to be caused by patient's movement. We also evaluated the tumor extension to the skull base in 81 patients. They were 24 brain tumors, 21 pituitary adenomas, and 36 nasopharyngeal and paranasal cancers. Four out of 24 brain tumors showed extracranial extension, 12 pituitary adenomas infiltrating outside of the sella turcica, and 10 cases of nasopharyngeal cancers showed intracranial extension. It was concluded that CT presented an excellent information in evaluating the degree of extension of neoplasms which invading to the skull base. (author)

  5. Utility of F-18 FDG PET/CT on the evaluation of primary bone lymphoma.

    Science.gov (United States)

    Wang, Li-Juan; Wu, Hu-Bing; Wang, Meng; Han, Yan-Jiang; Li, Hong-Sheng; Zhou, Wen-Lan; Wang, Quan-Shi

    2015-11-01

    Primary bone lymphoma (PBL) is a rare type of malignant lymphoma. Few data have been reported regarding the utility of F-18 FDG PET/CT in this disease. The aim of this study was to assess the role of F-18 FDG PET/CT in the diagnosis and therapeutic effect evaluation of PBL. A total of 19 consecutive patients with PBL were enrolled. Whole-body PET/CT scan was performed for all patients. The diagnosis of PBL was established by histopathology and immunohistochemistry. F-18 FDG PET/CT was positive in 94.7% (18/19) of patients. Uptake of FDG in lesions was intense with SUVmax of 15.14 ± 11.82. Multiple involved lesions were found in 47.4% (9/19) patients, while 52.6% presented with a single involved lesion. Based on the lesions, PET detected 98.9% (87/88) lesions. Among them, 71.6% (63/88) lesions were found to be located in axial skeleton and 28.4% (25/88) in the extremity skeleton. FDG PET/CT also found the lesions infiltrate to the surrounding soft tissue in 84.2% (16/19) patients. On the syn-modality CT, the bone destruction was noted in 43.2% (38/88) of the lesions, of which 50.0% lesions presented as slight change in bone density and 50.0% as severe change. The diagnostic sensitivity of PET was much higher than that of CT (98.9% vs. 43.2%, P=0.000). PET/CT was performed for evaluation of treatment response in 13 patients. In 12 patients with complete response(CR), PET/CT found the 25 lesions were F-18 FDG fully resoluted after treatment, however, bone destruction was still presented in 72.0% (18/25) lesions. The present study suggests that F-18 FDG PET/CT was a sensitive imaging modality for diagnosis and treatment response evaluation of PBL. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of 99Tcm-trodat-1 SPECT/CT imaging in the diagnosis of parkinson's disease in early stage

    International Nuclear Information System (INIS)

    Liu Xiaohua; Tai Jian; Zhang Fuhai; Xiao Qian; Jia Qiang; Dong Feng

    2004-01-01

    Parkinson's disease is a progressive neurodegenerative disorder characterized by a selective loss of dopamine in the striatum with age. At present, the diagnosis of Parkinson's disease is mainly remained in clinical standard. According to the clinical symptoms and the response to DOPA treatment, it is not difficult to diagnose typical PD. But it is difficult to diagnose early stage PD, which lacks the typical clinical symptoms and signs. A 99Tcm -labeled tropane derivative that binds to dopamine transporter with high selectivity is [2- [ [2- [ [ [3- (4-chlorophenyl)- 8-methyl- 8-azabicyclo [3,2,1 ] oct-2-yl]methyl] (2-mercaptoethyl)amino] eth yl]amino]ethanethiolato(3-)-N2,N2',S2,S2'] oxo-[1R-(exo-exo)] (TRODAT-1). Objective: The purpose of this study is to evaluate the clinical application of 99Tcm-TRODAT-1 SPECT/CT imaging in the diagnosis of Parkinson's disease (PD) in early stage. Methods: Twenty-four patients with early-stage idiopathic Parkinson's disease were recruited. For all patients, the severity was assessed by the Hoehnand Yahrscale. Twenty-four early stage PD patients (15 Hoehn Yahr stage I and 9 Hoehn Yahr stage II), eight advanced PD patients and ten healthy volunteers (five men, five women) were studied by 99Tcm-TRODAT-1 SPECT/CT imaging. 99Tcm-TRODAT-1 was prepared from a lyophilized kit. Brain SPECT imaging was performed 2 hours after injection, using GE Discovery VH equipped with FanBeam collimators. Data were obtained using energy window of 20% centered on 140 KEV for 99Tcm. The brain SPECT data were acquired after Hawkeye CT acquisition. Regions of interest were delineated over the striata and the cerebella, and the ratios of striatum-to-cerebellum (ST/CB) were calculated. Specific uptake in the striatum and its subregions, including the putamen and caudate nucleus, was calculated and compared with that of the other side as well as that of healthy volunteers. Results: Dopamine transporter (DAT) imaging of the 10 healthy volunteers showed

  7. Automated Detection of Healthy and Diseased Aortae from Images Obtained by Contrast-Enhanced CT Scan

    Directory of Open Access Journals (Sweden)

    Michael Gayhart

    2013-01-01

    Full Text Available Purpose. We developed the next stage of our computer assisted diagnosis (CAD system to aid radiologists in evaluating CT images for aortic disease by removing innocuous images and highlighting signs of aortic disease. Materials and Methods. Segmented data of patient’s contrast-enhanced CT scan was analyzed for aortic dissection and penetrating aortic ulcer (PAU. Aortic dissection was detected by checking for an abnormal shape of the aorta using edge oriented methods. PAU was recognized through abnormally high intensities with interest point operators. Results. The aortic dissection detection process had a sensitivity of 0.8218 and a specificity of 0.9907. The PAU detection process scored a sensitivity of 0.7587 and a specificity of 0.9700. Conclusion. The aortic dissection detection process and the PAU detection process were successful in removing innocuous images, but additional methods are necessary for improving recognition of images with aortic disease.

  8. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schlattmann, Peter [University Hospital of Friedrich-Schiller University Jena, Department of Medical Statistics, Informatics and Documentation, Jena (Germany); Schuetz, Georg M. [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, Marc [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2011-09-15

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with {<=}16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  9. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    International Nuclear Information System (INIS)

    Schlattmann, Peter; Schuetz, Georg M.; Dewey, Marc

    2011-01-01

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with ≤16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  10. Weight preserving image registration for monitoring disease progression in lung CT.

    Science.gov (United States)

    Gorbunova, Vladlena; Lol, Pechin; Ashraf, Haseem; Dirksen, Asger; Nielsen, Mads; de Bruijne, Marleen

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan compared with intensities in the deformed baseline image indicate local loss of lung tissue that is associated with progression of emphysema. To account for differences in lung intensity owing to differences in the inspiration level in the two scans rather than disease progression, we propose to adjust the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans and may result in a more sensitive measure of disease progression than standard quantitative CT measures.

  11. Treatment response evaluation with 18F-FDG PET/CT and 18F-NaF PET/CT in multiple myeloma patients undergoing high-dose chemotherapy and autologous stem cell transplantation.

    Science.gov (United States)

    Sachpekidis, Christos; Hillengass, J; Goldschmidt, H; Wagner, B; Haberkorn, U; Kopka, K; Dimitrakopoulou-Strauss, A

    2017-01-01

    The aim of this study was to assess the combined use of the radiotracers 18 F-FDG and 18 F-NaF in treatment response evaluation of a group of multiple myeloma (MM) patients undergoing high-dose chemotherapy (HDT) followed by autologous stem cell transplantation (ASCT) by means of static (whole-body) and dynamic PET/CT (dPET/CT). Thirty-four patients with primary, previously untreated MM scheduled for treatment with HDT followed by ASCT were enrolled in the study. All patients underwent PET/CT scanning with 18 F-FDG and 18 F-NaF before and after therapy. Treatment response by means of PET/CT was assessed according to the European Organization for Research and Treatment of Cancer (EORTC) 1999 criteria. The evaluation of dPET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modelling and a non-compartmental approach leading to the extraction of fractal dimension (FD). An analysis was possible in 29 patients: three with clinical complete response (CR) and 26 with non-CR (13 patients near complete response-nCR, four patients very good partial response-VGPR, nine patients partial response-PR). After treatment, 18 F-FDG PET/CT was negative in 14/29 patients and positive in 15/29 patients, showing a sensitivity of 57.5 % and a specificity of 100 %. According to the EORTC 1999 criteria, 18 F-FDG PET/CT-based treatment response revealed CR in 14 patients ( 18 F-FDG PET/CT CR), PR in 11 patients ( 18 F-FDG PET/CT PR) and progressive disease in four patients ( 18 F-FDG PET/CT PD). In terms of 18 F-NaF PET/CT, 4/29 patients (13.8 %) had a negative baseline scan, thus failed to depict MM. Regarding the patients for which a direct lesion-to-lesion comparison was feasible, 18 F-NaF PET/CT depicted 56 of the 129 18 F-FDG positive lesions (43 %). Follow-up 18 F-NaF PET/CT showed persistence of 81.5 % of the baseline 18 F-NaF positive MM lesions after treatment, despite the fact that 64

  12. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  13. 18F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    International Nuclear Information System (INIS)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober; Middendorp, Markus; Mack, Martin; Vogl, Thomas J.; Bisdas, Sotirios

    2009-01-01

    The purpose of this paper is to evaluate the impact of adding combined 18 F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P≥0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6±18.6 ml, the mean volume derived by the MR imaging was 17.6±19.1 ml while the estimated by PET/CT volume was 18.8±18.1 ml (P≤0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  14. Cardiovascular disease prediction: do pulmonary disease-related chest CT features have added value?

    International Nuclear Information System (INIS)

    Jairam, Pushpa M.; Jong, Pim A. de; Mali, Willem P.T.M.; Isgum, Ivana; Graaf, Yolanda van der

    2015-01-01

    Certain pulmonary diseases are associated with cardiovascular disease (CVD). Therefore we investigated the incremental predictive value of pulmonary, mediastinal and pleural features over cardiovascular imaging findings. A total of 10,410 patients underwent diagnostic chest CT for non-cardiovascular indications. Using a case-cohort approach, we visually graded CTs from the cases and from an approximately 10 % random sample of the baseline cohort (n = 1,203) for cardiovascular, pulmonary, mediastinal and pleural findings. The incremental value of pulmonary disease-related CT findings above cardiovascular imaging findings in cardiovascular event risk prediction was quantified by comparing discrimination and reclassification. During a mean follow-up of 3.7 years (max. 7.0 years), 1,148 CVD events (cases) were identified. Addition of pulmonary, mediastinal and pleural features to a cardiovascular imaging findings-based prediction model led to marginal improvement of discrimination (increase in c-index from 0.72 (95 % CI 0.71-0.74) to 0.74 (95 % CI 0.72-0.75)) and reclassification measures (net reclassification index 6.5 % (p < 0.01)). Pulmonary, mediastinal and pleural features have limited predictive value in the identification of subjects at high risk of CVD events beyond cardiovascular findings on diagnostic chest CT scans. (orig.)

  15. Cardiovascular disease prediction: do pulmonary disease-related chest CT features have added value?

    Energy Technology Data Exchange (ETDEWEB)

    Jairam, Pushpa M. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Jong, Pim A. de; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Isgum, Ivana [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Graaf, Yolanda van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Collaboration: PROVIDI study-group

    2015-06-01

    Certain pulmonary diseases are associated with cardiovascular disease (CVD). Therefore we investigated the incremental predictive value of pulmonary, mediastinal and pleural features over cardiovascular imaging findings. A total of 10,410 patients underwent diagnostic chest CT for non-cardiovascular indications. Using a case-cohort approach, we visually graded CTs from the cases and from an approximately 10 % random sample of the baseline cohort (n = 1,203) for cardiovascular, pulmonary, mediastinal and pleural findings. The incremental value of pulmonary disease-related CT findings above cardiovascular imaging findings in cardiovascular event risk prediction was quantified by comparing discrimination and reclassification. During a mean follow-up of 3.7 years (max. 7.0 years), 1,148 CVD events (cases) were identified. Addition of pulmonary, mediastinal and pleural features to a cardiovascular imaging findings-based prediction model led to marginal improvement of discrimination (increase in c-index from 0.72 (95 % CI 0.71-0.74) to 0.74 (95 % CI 0.72-0.75)) and reclassification measures (net reclassification index 6.5 % (p < 0.01)). Pulmonary, mediastinal and pleural features have limited predictive value in the identification of subjects at high risk of CVD events beyond cardiovascular findings on diagnostic chest CT scans. (orig.)

  16. Creation and evaluation of complementary composite three-dimensional image in various brain diseases. An application of three-dimensional brain SPECT image and three-dimensional CT image

    International Nuclear Information System (INIS)

    Seiki, Yoshikatsu; Shibata, Iekado; Mito, Toshiaki; Sugo, Nobuo

    2000-01-01

    The purpose of this study was to develop 3D composite images for use in functional and anatomical evaluation of various cerebral pathologies. Imaging studies were performed in normal volunteers, patients with hydrocephalus and patients with brain tumor (meningioma and metastatic tumor) using a three-detector SPECT system (Prism 3000) and helical CT scanner (Xvigor). 123 I-IMP was used in normal volunteers and patients with hydrocephalus, and 201 TLCL in patients with brain tumor. An Application Visualization System-Medical Viewer (AVS-MV) was used on a workstation (Titan 2) to generate 3D images. A new program was developed by synthesizing surface rendering and volume rendering techniques. The clinical effects of shunt operations were successfully evaluated in patients with hydrocephalus by means of translucent 3D images of the deep brain. Changes in the hypoperfusion area around the cerebral ventricle were compared with morphological changes in the cerebral ventricle on CT. In addition to the information concerning the characteristics of brain tumors and surrounding edemas, hemodynamic changes and changeable hypoperfusion areas around the tumors were visualized on 3D composite CT and SPECT images. A new method of generating 3D composite images of CT and SPECT was developed by combining graphic data from different systems on the same workstation. Complementary 3D composite images facilitated quantitative analysis of brain volume and functional analysis in various brain diseases. (author)

  17. Quantitative measurement of lung density with x-ray CT and positron CT, (2). Diseased subjects

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-05-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm/sup 3/), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm/sup 3/) with increased extravascular lung density (0.23gcm/sup 3/). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm/sup 3/ and 0.10mlcm/sup 3/ respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases.

  18. Brain atrophy in Huntington's disease: A CT-scan study

    International Nuclear Information System (INIS)

    Starkstein, S.E.; Folstein, S.E.; Brandt, J.; McDonnell, A.; Folstein, M.

    1989-01-01

    CT-scan measurements of cortical and subcortical atrophy were carried out in 34 patients with Huntington's disease (HD). While a significant correlation was observed between parameters of subcortical atrophy (bicaudate ratio, bifrontal ratio and third ventricular ratio) and duration of the disease, there was no significant correlation between these parameters and age. On the other hand, measurements of cortical atrophy (frontal fissure ratio and cortical sulci ratio) correlated significantly with age but not with duration of the disease. When a group of 24 HD patients were compared on CT-scan measurements with a group of 24 age-matched normal controls, significant differences were obtained for all the variables examined, but the bicaudate ratio showed the highest sensitivity and specificity. Even mildly affected patients, with duration of motor symptoms less than 3 years had higher bicaudate ratios than age-matched controls. (orig.)

  19. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  20. Pulmonary light-chain deposition disease: CT and pathology findings in nine patients

    International Nuclear Information System (INIS)

    Sheard, S.; Nicholson, A.G.; Edmunds, L.; Wotherspoon, A.C.; Hansell, D.M.

    2015-01-01

    Aim: To review the clinical features of nine patients with pulmonary light-chain deposition disease (LCDD) and record their high-resolution CT (HRCT) and histopathological findings. Materials and methods: Patients with a diagnosis of LCDD on lung biopsy specimen were retrospectively identified. The HRCT characteristics of nodules, cysts, and ancillary findings; change at follow-up; and histopathological findings were documented. Results: Features common to all nine cases were thin-walled cysts. In seven cases, vessels traversing the cysts were identified. The majority of patients (8/9) had at least one pulmonary nodule. There was no zonal predominance of either cysts or nodules. The disease appeared stable in the majority of cases with no serial change in HRCT appearances (5/6 cases with follow-up data, mean duration 29 months). Conclusion: To the authors' knowledge, this is the largest series of pulmonary LCDD patients in the literature, and the first systematic assessment of HRCT findings. Pulmonary cysts are a unifying feature, usually with pulmonary nodules, and serial change on HRCT is unusual. - Highlights: • Nine cases of pulmonary light chain deposition disease with high-resolution CT. • CT scans assessed for abnormal features. • Clinical data and histopathological findings obtained. • All patients had thin-walled cysts on CT, often with traversing vessels. • CT features of disease in this group are cysts, nodules and an indolent course

  1. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De [Chonnam Univ. Medical School, Kwangju (Korea, Republic of)

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis.

  2. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis

  3. Use of CT in the evaluation of cochlear otosclerosis

    International Nuclear Information System (INIS)

    Mafee, M.F.; Valvassori, G.E.; Deitch, R.L.; Norouzi, P.; Henrikson, G.C.; Capek, V.; Applebaum, E.L.

    1985-01-01

    Otosclerosis (otospongiosis) occurs when the hard endochondral bone of the otic capsule is replaced by spongy vascular foci of haversian bone. Using computed tomography (CT), the authors studied the ears of 32 selected patients with mixed or sensorineural hearing loss; 24 were suspected of having otosclerosis. CT proved valuable in detecting cochlear otosclerosis, foci of demineralization, and changes in bony texture and enables the easy recognition of subtle radiographic findings. This paper also reports the CT findings of temporal bones in osteogenesis imperfecta and Paget disease

  4. Automated volumetry of temporal horn of lateral ventricle for detection of Alzheimer's disease in CT scan

    Science.gov (United States)

    Takahashi, Noriyuki; Kinoshita, Toshibumi; Ohmura, Tomomi; Matsuyama, Eri; Toyoshima, Hideto

    2018-02-01

    The rapid increase in the incidence of Alzheimer's disease (AD) has become a critical issue in low and middle income countries. In general, MR imaging has become sufficiently suitable in clinical situations, while CT scan might be uncommonly used in the diagnosis of AD due to its low contrast between brain tissues. However, in those countries, CT scan, which is less costly and readily available, will be desired to become useful for the diagnosis of AD. For CT scan, the enlargement of the temporal horn of the lateral ventricle (THLV) is one of few findings for the diagnosis of AD. In this paper, we present an automated volumetry of THLV with segmentation based on Bayes' rule on CT images. In our method, first, all CT data sets are normalized into an atlas by using linear affine transformation and non-linear wrapping techniques. Next, a probability map of THLV is constructed in the normalized data. Then, THLV regions are extracted based on Bayes' rule. Finally, the volume of the THLV is evaluated. This scheme was applied to CT scans from 20 AD patients and 20 controls to evaluate the performance of the method for detecting AD. The estimated THLV volume was markedly increased in the AD group compared with the controls (P < .0001), and the area under the receiver operating characteristic curve (AUC) was 0.921. Therefore, this computerized method may have the potential to accurately detect AD on CT images.

  5. Cerebral blood flow mapping using stable xenon-enhanced CT in sickle cell cerebrovascular disease

    International Nuclear Information System (INIS)

    Numaguchi, Y.; Robinson, A.E.; Carey, J.E.

    1990-01-01

    The cerebral blood flow (CBF) of 25 patients with sickle cell cerebrovascular disease (SCCVD) was examined using a xenon-CT flow mapping method. Brain CT and MR findings were correlated with those of the xenon-CT flow studies. CBF defects on xenon-CT correlated reasonably well with the areas of cortical infarctions on the MR images, but in 27% of the cases, flow defects were slightly larger than the areas of infarctions on the MR images. In deep watershed or basal ganglia infarctions, abnormal CBF was noted about the cerebral cortex near infarctions in 72% of the patients, regardless of infarction sizes on the MR images. However, decreased CBF was recognized in 4 of the 9 children whose MR images were virtually normal. Thus, the extent of flow depletion cannot be predicted accurately by MR imaging alone. Xenon-CT flow mapping proved a safe and reliable procedure for evaluation of the CBF of patients with SCCVD. Although this study is preliminary, it may have a potential in selecting patients for hypertransfusion therapy, as a noninvasive test and for following children with SCCVD during their therapy. Careful correlation of results of CBF with those of MR imaging or of CT is important for objective interpretations of flow mapping images. (orig.)

  6. The importance of PET/CT in the evaluation of patients with Ewing tumors

    Directory of Open Access Journals (Sweden)

    Júlio Brandão Guimarães

    2015-06-01

    Full Text Available Abstract The effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging.

  7. Anatomy and function: PET-CT.

    Science.gov (United States)

    Kajander, Sami; Saraste, Antti; Ukkonen, Heikki; Knuuti, Juhani

    2010-05-01

    CT coronary angiography and perfusion PET form an attractive combination to study coronary artery lesions and their consequences in patients with coronary artery disease. Whereas CT provides non-invasive assessment of coronary lumen and wall, PET perfusion is a reliable method for the evaluation of myocardial flow. CT, although very capable of ruling out significant coronary artery disease, is less than satisfactory in assessing the actual significance of the detected lesions. PET imaging, despite its excellent sensitivity, fails to describe the exact anatomy of the epicardial vessels. By fusing image data from these two modalities, lesions can be accurately correlated with their physiological or anatomical counterparts. Hybrid PET-CT devices, now in wide clinical use, allow such fusion in a one-stop-shop study. Although still seeking its place in clinical scenarios, growing evidence suggests that hybrid PET-CT imaging of coronary anatomy and myocardial perfusion can accurately - and non-invasively - assess the existence and degree of coronary artery disease.

  8. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  9. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong-Ryool; Min, Jung-Joon [Chonnam National Univ. Hwasun Hospital, Hwasun (Korea, Republic of); Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P. [Nuclear Medicine and Center for PET/CT, Zentralk Bad Berka, Bad Verka (Germany)

    2012-06-15

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease.

  10. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Min, Jung-Joon; Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P.

    2012-01-01

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease

  11. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  12. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast...... establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone....... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT...

  13. {sup 18}F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober [JW Goethe University, Department of Oromaxillofacial Surgery, Frankfurt (Germany); Middendorp, Markus [JW Goethe University, Department of Nuclear Medicine, Frankfurt (Germany); Mack, Martin; Vogl, Thomas J. [JW Goethe University, Department of Radiology, Frankfurt (Germany); Bisdas, Sotirios [Eberhard Karls University, Department of Neuroradiology, Tuebingen (Germany)

    2009-10-15

    The purpose of this paper is to evaluate the impact of adding combined {sup 18}F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P{>=}0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6{+-}18.6 ml, the mean volume derived by the MR imaging was 17.6{+-}19.1 ml while the estimated by PET/CT volume was 18.8{+-}18.1 ml (P{<=}0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  14. Use of (18)F-FDG PET/CT in the preoperative evaluation of patients diagnosed with peritoneal carcinomatosis of ovarian origin, candidates to cytoreduction and hipec. A pending issue.

    Science.gov (United States)

    Lopez-Lopez, V; Cascales-Campos, P A; Gil, J; Frutos, L; Andrade, R J; Fuster-Quiñonero, M; Feliciangeli, E; Gil, E; Parrilla, P

    2016-10-01

    To evaluate the clinical usefulness of the results obtained with (18)F-FDG PET/CT in relation to CT in the preoperative staging of patients with peritoneal carcinomatosis secondary to primary or recurrent ovarian cancer candidates to cytoreductive surgery and hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC). A retrospective study comparing the results obtained with CT and (18)F-FDG PET/CT in the preoperative evaluation of a series of 59 patients was performed. In all patients the peritoneal carcinomatosis index (PCI) was determined by preoperative radiological CT and 18F-FDG PET/CT and compared with surgical PCI, which was considered as reference. Of the 59 patients studied, in 55 peritoneal carcinomatosis presences were confirmed (4 patients had complete responses to neoadjuvant chemotherapy). The mean surgical, CT and 18F-FDG PET/CT PCI was 9.46±7.70, 3.69±3.96 and 2.25±1.02, respectively. In the global disease detection, CT showed a higher positive likelihood ratio (LR+) than (18)F-FDG PET/CT (15.3, 95% CI 8.35-28.04 vs. 3.47, 95% CI 3.36-5.11) and a lower negative likelihood ratio (LR-) than 18F-FDG PET/CT (0.67, 95% CI 0.61-0.73 vs. 0.82, 95% CI 0.76-0.88). In every region of the abdomen the CT showed a greater LR+ than 18F-FDG PET/CT and a lower LR- than 18F-FDG PET/CT. CT showed the best diagnostic results compared to (18)F-FDG PET/CT to confirme the presence of peritoneal disease. The lower performance of the (18)F-FDG PET/CT suggests that the main utility of (18)F-FDG PET/CT is to evaluate a possible metastatic extraperitoneal spread of the disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  16. The effect of CT urography in the diagnosis of non-calculous urinary obstruction diseases

    International Nuclear Information System (INIS)

    Zhang Zhuiyang; Shen Yuanliang; Li Xin; Cao Rongmei; Xu Xiqi; Dong Jian; Hua Dongying

    2004-01-01

    Objective: To evaluate the diagnostic effect of CT urography (CTU) in patients with non-calculous obstructive diseases of urinary tract. Methods: Forty cases with non-calculous urinary obstruction underwent helical CT during nephrographic and excretory phases. Three dimensional CTU was obtained with the reconstruction of excretory phase axial images through the workstation. Results: 24 of 40 cases with benign obstruction had a slight or severe urinary dilation. Among them,18 congenital urinary malformations showed specific findings. Four ureteric inflammations revealed a gradual taper of the lumen just like a beak, and another two prostatic hypertrophy appeared oval impression upon the middle of the posterior bladder. Six intrinsic and 10 extrinsic tumors were seen irregular filling defects of the urinary tracts as well as soft tissue mass surrounding the obstructive site, accompanied by the middle urinary dilation in 12 cases and severe in four. Meanwhile, bilateral ureterohydronephroses were also found in four extrinsic tumors. In six patients with unilateral nonfunctioning urinary tracts, CTU could be imaged with minimum intensity projection (MinIP) and then be merged with contralateral maximum intensity projection (MaxIP). Conclusion: CTU is an effective modality in the evaluation of non-calculous urinary obstruction diseases. (authors)

  17. Cone beam CT for organs motion evaluation in pediatric abdominal neuroblastoma

    International Nuclear Information System (INIS)

    Nazmy, Mohamed Soliman; Khafaga, Yasser; Mousa, Amr; Khalil, Ehab

    2012-01-01

    Background and purpose: To quantify the organ motion relative to bone in different breathing states in pediatric neuroblastoma using cone beam CT (CBCT) for better definition of the planning margins during abdominal IMRT. Methods and materials: Forty-two datasets of kV CBCT for 9 pediatric patients with abdominal neuroblastoma treated with IMRT were evaluated. Organs positions on planning CT scan were considered the reference position against which organs and target motions were evaluated. The position of the kidneys and the liver was assessed in all scans. The target movement was evaluated in four patients who were treated for gross residual disease. Results: The mean age of the patients was 4.1 ± 1.6 years. The range of target movement in the craniocaudal direction (CC) was 5 mm. In the CC direction, the range of movement was 10 mm for the right kidney, and 8 mm for the left kidney. Similarly, the liver upper edge range of motion was 11 mm while the lower edge range of motion was 13 mm. Conclusions: With the use of daily CBCT we may be able to reduce the PTV margin. If CBCT is not used daily, a wider margin is needed.

  18. Feasibility of Single Scan for Simultaneous Evaluation of Regional Krypton and Iodine Concentrations with Dual-Energy CT: An Experimental Study.

    Science.gov (United States)

    Hong, Sae Rom; Chang, Suyon; Im, Dong Jin; Suh, Young Joo; Hong, Yoo Jin; Hur, Jin; Kim, Young Jin; Choi, Byoung Wook; Lee, Hye-Jeong

    2016-11-01

    Purpose To evaluate the feasibility of a simultaneous single scan of regional krypton and iodine concentrations by using dual-energy computed tomography (CT). Materials and Methods The study was approved by the institutional animal experimental committee. An airway obstruction model was first made in 10 beagle dogs, and a pulmonary arterial occlusion was induced in each animal after 1 week. For each model, three sessions of dual-energy CT (80% krypton ventilation [krypton CT], 80% krypton ventilation with iodine enhancement [mixed-contrast agent CT], and iodine enhancement [iodine CT]) were performed. Krypton maps were made from krypton and mixed-contrast agent CT, and iodine maps were made from iodine and mixed-contrast agent CT. Observers measured overlay Hounsfield units of the diseased and contralateral segments on each map. Values were compared by using the Wilcoxon signed-rank test. Results In krypton maps of airway obstruction, overlay Hounsfield units of diseased segments were significantly decreased compared with those of contralateral segments in both krypton and mixed-contrast agent CT (P = .005 for both). However, the values of mixed-contrast agent CT were significantly higher than those of krypton CT for both segments (P = .005 and .007, respectively). In iodine maps of pulmonary arterial occlusion, values were significantly lower in diseased segments than in contralateral segments for both iodine and mixed-contrast agent CT (P = .005 for both), without significant difference between iodine and mixed-contrast agent CT for both segments (P = .126 and .307, respectively). Conclusion Although some limitations may exist, it might be feasible to analyze regional krypton and iodine concentrations simultaneously by using dual-energy CT. © RSNA, 2016.

  19. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  20. Evaluation of computer-based computer tomography stratification against outcome models in connective tissue disease-related interstitial lung disease: a patient outcome study.

    Science.gov (United States)

    Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M

    2016-11-23

    To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively

  1. Treatment response evaluation with {sup 18}F-FDG PET/CT and {sup 18}F-NaF PET/CT in multiple myeloma patients undergoing high-dose chemotherapy and autologous stem cell transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Sachpekidis, Christos [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); University of Bern, Department of Nuclear Medicine, Inselspital, Bern University Hospital, Bern (Switzerland); Hillengass, J.; Wagner, B. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); Goldschmidt, H. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); National Center for Tumor Diseases (NCT) Heidelberg, Heidelberg (Germany); Haberkorn, U. [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); University of Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Kopka, K. [German Cancer Research Center (DKFZ), Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Dimitrakopoulou-Strauss, A. [German Cancer Research Center (DKFZ), Medical PET Group-Biological Imaging, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2017-01-15

    The aim of this study was to assess the combined use of the radiotracers {sup 18}F-FDG and {sup 18}F-NaF in treatment response evaluation of a group of multiple myeloma (MM) patients undergoing high-dose chemotherapy (HDT) followed by autologous stem cell transplantation (ASCT) by means of static (whole-body) and dynamic PET/CT (dPET/CT). Thirty-four patients with primary, previously untreated MM scheduled for treatment with HDT followed by ASCT were enrolled in the study. All patients underwent PET/CT scanning with {sup 18}F-FDG and {sup 18}F-NaF before and after therapy. Treatment response by means of PET/CT was assessed according to the European Organization for Research and Treatment of Cancer (EORTC) 1999 criteria. The evaluation of dPET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modelling and a non-compartmental approach leading to the extraction of fractal dimension (FD). An analysis was possible in 29 patients: three with clinical complete response (CR) and 26 with non-CR (13 patients near complete response-nCR, four patients very good partial response-VGPR, nine patients partial response-PR). After treatment, {sup 18}F-FDG PET/CT was negative in 14/29 patients and positive in 15/29 patients, showing a sensitivity of 57.5 % and a specificity of 100 %. According to the EORTC 1999 criteria, {sup 18}F-FDG PET/CT-based treatment response revealed CR in 14 patients ({sup 18}F-FDG PET/CT CR), PR in 11 patients ({sup 18}F-FDG PET/CT PR) and progressive disease in four patients ({sup 18}F-FDG PET/CT PD). In terms of {sup 18}F-NaF PET/CT, 4/29 patients (13.8 %) had a negative baseline scan, thus failed to depict MM. Regarding the patients for which a direct lesion-to-lesion comparison was feasible, {sup 18}F-NaF PET/CT depicted 56 of the 129 {sup 18}F-FDG positive lesions (43 %). Follow-up {sup 18}F-NaF PET/CT showed persistence of 81.5 % of the baseline {sup 18}F

  2. Longitudinal micro-CT as an outcome measure of interstitial lung disease in TNF-transgenic mice.

    Directory of Open Access Journals (Sweden)

    Richard D Bell

    Full Text Available Rheumatoid arthritis associated interstitial lung disease (RA-ILD is a debilitating condition with poor survival prognosis. High resolution computed tomography (CT is a common clinical tool to diagnose RA-ILD, and is increasingly being adopted in pre-clinical studies. However, murine models recapitulating RA-ILD are lacking, and CT outcomes for inflammatory lung disease have yet to be formally validated. To address this, we validate μCT outcomes for ILD in the tumor necrosis factor transgenic (TNF-Tg mouse model of RA.Cross sectional μCT was performed on cohorts of male TNF-Tg mice and their WT littermates at 3, 4, 5.5 and 12 months of age (n = 4-6. Lung μCT outcomes measures were determined by segmentation of the μCT datasets to generate Aerated and Tissue volumes. After each scan, lungs were obtained for histopathology and 3 sections stained with hematoxylin and eosin. Automated histomorphometry was performed to quantify the tissue area (nuclei, cytoplasm, and extracellular matrix and aerated area (white space within the tissue sections. Spearman's correlation coefficients were used to evaluate the extent of association between μCT imaging and histopathology endpoints.TNF-Tg mice had significantly greater tissue volume, total lung volume and mean intensity at all timepoints compared to age matched WT littermates. Histomorphometry also demonstrated a significant increase in tissue area at 3, 4, and 5.5 months of age in TNF-Tg mice. Lung tissue volume was correlated with lung tissue area (ρ = 0.81, p<0.0001, and normalize lung aerated volume was correlated with normalized lung air area (ρ = 0.73, p<0.0001.We have validated in vivo μCT as a quantitative biomarker of ILD in mice. Further, development of longitudinal measures is critical for dissecting pathologic progression of ILD, and μCT is a useful non-invasive method to study lung inflammation in the TNF-Tg mouse model.

  3. A case of Neuro-Behcet's disease with an interesting CT scan picture

    International Nuclear Information System (INIS)

    Sato, Jinichi; Kamitani, Hiroshi; Masuzawa, Hideaki; Matsui, Takayoshi; Mizobe, Masafumi.

    1981-01-01

    A Case of Neuro-Behcet's disease with an interesting CT scan picture was reported. A 31-year-old man with a known history of Behcet's disease was transferred to the Kantoh-Teishin Hospital upon suspicion of a brain tumor in the basal ganglia. Right hemiparesis and mild dysarthria of three weeks' duration and long-standing bilateral blindness were noted. Computerized tomography (CT) demonstrated an enhanced mass in the basal ganglia and surrounding irregular, low-density area in the white matter of the left frotoparietal lobe. The ventricles were shifted to the right. Left carotid angiography revealed a shift of the anterior cerebral artery to the right and a mild deformity of the Sylvian triangle. No tumor stain or abnormal vessels were seen. After high doses of prednisolone, his condition gradually improved. A CT scan two weeks later revealed a decrease in the low-density area and the mass effect, but an unchanged pathological contrast enhancement in the basal ganglia. The contrast enhancement lasted for two months. The CT scan of Neuro-Behcet's disease was discussed. (author)

  4. CT evaluation of thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Hee [Insung Hospital, Chuncheon (Korea, Republic of); Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness.

  5. CT evaluation of thymus in myasthenia gravis

    International Nuclear Information System (INIS)

    Kim, Guk Hee; Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck

    1989-01-01

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness

  6. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  7. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  8. The application of PET/CT in immunoglobulin G4-related disease

    International Nuclear Information System (INIS)

    Zhang Huiwei; Zhao Jun

    2013-01-01

    Immunoglobulin G4 (IgG4)-related disease is a kind of new systemic entity characterized by mass-forming lesions in various organs that consist of lymphoplasmacytic infiltrates and fibrosclerosis with numerous IgG4-positive plasma cells. PET/CT has been widely used in clinical as a whole body examination that earned plenty of successful experience, especially in multiple locations and organs cancer such as lymphoma. PET/CT also has a potential application in IgG4-related diseases as its feature of systemic. (authors)

  9. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  10. Acquired cystic kidney disease in dialysis and renal transplant patients: ultrasonography and CT analysis

    International Nuclear Information System (INIS)

    Jeon, Young Tae; Lee, Hae Kyung; Jung, Mi Sun; Yoon, Jong Pil; Hong, Hyun Sook; Kwon, Kui Hyang; Choi, Deuk Lin; Hwang, Seung Duk; Lee, Hi Bahl

    1997-01-01

    To evaluate by US and CT the incidence and complications of acquired cystic kidney disease (ACKD) in dialysis and renal transplant patients and to compare the effectiveness of US and CT in the diagnosis of this entity. This study was prospectively performed in 70 dialysis patients and 13 renal transplant patients, and excluded any with multiple renal cysts or polycystic kidney disease, on as seen on initial films. US were obtained in all patients, and CT scans were randomly obtained in 27 who had been on dialysis for 3 years or more; all these US and CT scans were analyzed, with particular emphasis on whether or not cysts were present. In order to correlate the numbers of cysts with duration of dialysis, all patients were assigned to one of three groups, according to the number of cysts found (group 1, 0; group 2, 1-4; group 3, >4). Only group 3 was diagnosed as suffering from ACKD. In order to compare the cyst-detection capability of US with that of CT, 27 dialysis patients who had undergone US and CT were divided into four groups according to the number of cysts found (grade 1, 0; grade 2, 1-4; grade 3, 5-10; grade 4, >10). Seventy dialysis patients were divided according to the results of US, as follows : group 1, 20%; group 2, 47.1%; group 3, 32.9%. The mean duration of dialysis in group 1 (31.9 months) was statistically different from that in group 2 (50.6 months) and in group 3 (95.8 months) (p < 0.000). Thirteen renal transplant patients were divided as follows : group 1, 61.5%; group 2, 38.5%; group 3, 0%. In dialysis patients with ACKD, complications noted were renal cell carcinoma (n=1), hemorrhagic cysts (n=2), and hematomas (n=2). Among the 27 dialysis patients who underwent CT, this and US showed an equal grade of cystic change in 53.7%, while CT showed a higher grade in 46.3%. The detection rate of ACKD in these 27 patients was 46% on US and 63% on CT. A prolongation of dialysis corresponded to an increased incidence of ACKD; renal neoplasm and

  11. CT staging of renal pelvis tumor

    International Nuclear Information System (INIS)

    Yoon, Soo Woong; Cho, Kyoung Sik; Lee, Jong Hwa; Ham, Su Yeon; Won, Yeong Cheol; Ji, Eun Kyung; Choi, Seong Hun; Shin, Byung Suck

    1999-01-01

    To assess the value of computed tomography (CT) in the preoperative staging of transitional cell carcinoma (TCC) of the renal pelvis. We retrospectively evaluated the CT TNM staging of 38 patients with TCC of the renal pelvis who had undergone preoperative abdominal CT examination between January 1990 and January 1998. In CT staging for differentiation between early-stage (T0-2) and advanced-stage disease (T3-T4), three criteria were used, namely the presence or obliteration of the renal sinus fat layer, the smoothness or irregularity of margin between the tumor and renal parenchyma, and the presence or absence of hydronephrosis proximal to the tumor. CT staging was performed by two genitourinary radiologists blinded to the pathologic results, and was compared with pathologic staging. Pathologic results revealed 19 cases of early stage disease (T0=8, T1=9, T2=2) and 19 of advanced stage (T3=12, T4=7). Overall CT staging accuracy was 82%(31/38) ; four cases were overstaged and three were understaged. In early-stage disease, sensitivity and specificity were 79%, and 84%, and in advanced stage disease were 83% and 80%. Three of four overstaged cases showed hydronephrosis proximal to the tumor. In the second CT staging, using proximal hydronephrosis of the tumor as a criterion for early-stage disease, the sensitivity and specificity of early-stage disease were 95% and 75%, respectively, and the specificity of advanced-stage disease was 95%. When hydronephrosis proximal to a tumor was considered to be a sign of early stage disease, the CT staging of renal pelvic TCC was highly accurate

  12. Bilateral primary renal lymphoma in a pediatric patient: staging and response evaluation with ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    Dhull, V S; Mukherjee, A; Karunanithi, S; Durgapal, P; Bal, C; Kumar, R

    2015-01-01

    Primary renal lymphoma (PRL) is a rare disease. We here present the case of an 8-year-old child who presented with bilateral renal masses. On biopsy, it was confirmed to be B-cell non-Hodgkin's lymphoma. (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography (PET/CT) for staging demonstrated (18)F-FDG avid bilateral renal masses, with no other abnormal focus. Follow up (18)F-FDG PET/CT showed complete resolution of the disease after six cycles of chemotherapy. Here we have highlighted the potential role of (18)F-FDG PET/CT in staging and response evaluation of a patient with PRL and presented a brief review. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  13. CT and conventional radiographic techniques in interstitial pulmonary disease

    International Nuclear Information System (INIS)

    Leipner, N.; Schueller, H.; Uexkuell-Gueldenband, V. v.; Schlolaut, K.H.; Overlack, A.; Bonn Univ.

    1988-01-01

    One hundred and sixty-four patients with pulmonary fibrosis were examined by CT and by conventional radiological methods. Sixty patients had asbestosis, thirty-nine silicosis, forty sarcoidosis and twenty-five had idiopathic pulmonary fibrosis. CT is superior to conventional radiography in evaluating interstitial pulmonary changes, particularly of the pleura and the lung parenchyma. In sixty-nine patients there were some findings which could only be demonstrated by CT. In asbestosis, silicosis and sarcoidosis the CT classification of the lung parenchyma which we have suggested produces significantly better correlation with vital capacity than can be achieved from conventional chest films, according to the guidelines of the I.L.O. (orig./GDG) [de

  14. Chest CT features of cystic fibrosis in Korea: Comparison with non-cystic fibrosis diseases

    International Nuclear Information System (INIS)

    Yang, So Yeon; Lee, Kyung Soo; Kim, Tae Jung; Kim, Tae Sung; Cha, Min Jae; Yoon, Hyun Jung

    2017-01-01

    Cystic fibrosis (CF) is a rare congenital disease in Korea, and its clinical and imaging findings are unclear. The objective of our study was to describe the clinical and CT features of CF in Korea and compare its features with those of other diseases mimicking CF. From November 1994 to December 2014, a presumptive diagnosis of CF was made in 23 patients based on clinical or radiological examination. After the exclusion of 10 patients without diagnostic confirmation, 13 patients were included in the study. A diagnosis of CF was made with the CF gene study. CT findings were evaluated for the presence and distribution of parenchymal abnormalities including bronchiectasis, tree-in-bud (TIB) pattern, mucus plugging, consolidation, and mosaic attenuation. Of the 13 patients, 7 (median age, 15 years) were confirmed as CF, 4 (median age, 19 years) had primary ciliary dyskinesia, 1 had bronchiectasis of unknown cause, and 1 had chronic asthma. CT of patients with CF showed bilateral bronchiectasis, TIB pattern, mosaic attenuation, and mucus plugging in all patients, with upper lung predominance (57%). In CT of the non-CF patients, bilateral bronchiectasis, TIB pattern, mosaic attenuation, and mucus plugging were also predominant features, with lower lung predominance (50%). Korean patients with CF showed bilateral bronchiectasis, cellular bronchiolitis, mucus plugging, and mosaic attenuation, which overlapped with those of non-CF patients. CF gene study is recommended for the definitive diagnosis of CF in patients with these clinical and imaging features

  15. Chest CT features of cystic fibrosis in Korea: Comparison with non-cystic fibrosis diseases

    Energy Technology Data Exchange (ETDEWEB)

    Yang, So Yeon; Lee, Kyung Soo; Kim, Tae Jung; Kim, Tae Sung [Dept. of Radiology, and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Cha, Min Jae [Dept. of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul (Korea, Republic of); Yoon, Hyun Jung [Dept. of Radiology, Hanyang University Hospital, Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    Cystic fibrosis (CF) is a rare congenital disease in Korea, and its clinical and imaging findings are unclear. The objective of our study was to describe the clinical and CT features of CF in Korea and compare its features with those of other diseases mimicking CF. From November 1994 to December 2014, a presumptive diagnosis of CF was made in 23 patients based on clinical or radiological examination. After the exclusion of 10 patients without diagnostic confirmation, 13 patients were included in the study. A diagnosis of CF was made with the CF gene study. CT findings were evaluated for the presence and distribution of parenchymal abnormalities including bronchiectasis, tree-in-bud (TIB) pattern, mucus plugging, consolidation, and mosaic attenuation. Of the 13 patients, 7 (median age, 15 years) were confirmed as CF, 4 (median age, 19 years) had primary ciliary dyskinesia, 1 had bronchiectasis of unknown cause, and 1 had chronic asthma. CT of patients with CF showed bilateral bronchiectasis, TIB pattern, mosaic attenuation, and mucus plugging in all patients, with upper lung predominance (57%). In CT of the non-CF patients, bilateral bronchiectasis, TIB pattern, mosaic attenuation, and mucus plugging were also predominant features, with lower lung predominance (50%). Korean patients with CF showed bilateral bronchiectasis, cellular bronchiolitis, mucus plugging, and mosaic attenuation, which overlapped with those of non-CF patients. CF gene study is recommended for the definitive diagnosis of CF in patients with these clinical and imaging features.

  16. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  17. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    Treatment strategy in patients with suspected coronary artery disease (CAD) is driven by symptomatology in combination with diagnostic evaluation of the extent and/or severity of atherosclerosis in the coronary arteries and ischemia in the myocardium, i.e., the anatomic and functional correlates of CAD. Whereas multislice row computed tomography (MSCT) has the advantage of detecting coronary atherosclerosis at its earliest stages, thereby allowing initiation of appropriate therapeutic measures well before development of obstructive CAD, myocardial perfusion imaging (MPI) SPECT can clarify the hemodynamic consequences of the anatomic findings on MSCT based on a functional assessment of myocardial blood flow. There is a lack of correlation between coronary artery calcium (CAC), coronary artery stenosis, and MPI SPECT. Therefore CAC scoring and stress MPI should be thus considered complementary approaches rather than exclusionary in the evaluation of the patient at risk for CAD. The integration of anatomic and functional information may provide additional information for the clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The majority of previous studies are based on a sequential flowchart, starting with either SPECT or CAC scoring that finally directs the therapeutic strategy. Patients at low risk for CAD can be selected for primary prevention, and patients at high risk for CAD can be directly selected for coronary angiography (CAG). The remaining group of patients at intermediate risk for CAD can be substratified into lower- and higher-risk categories based on the presence or absence of stress-induced ischemia on MPI SPECT and CAC scoring. An integration of SPECT and CAC as a starting point for CAD detection in symptomatic patients at intermediate risk for CAD may facilitate a tailored diagnostic as well as therapeutic approach. Finally, using SPECT/CT, MPI SPECT, and CAC findings may be completed with CT angiography

  18. CT in the evaluation of severe liver trauma

    International Nuclear Information System (INIS)

    Machado, Marcel Autran C.; Souza Rocha, Manoel de; Machado, Manoel C.C.; Macedo Neto, Augusto Cesar de; Maciel, Rosangela Pereira; Simonetti, Celso.

    1995-01-01

    Abdominal CT is a common examination in the evaluation of patients with blunt abdominal trauma and clinical suspicion for solid organ injury when reasons for immediate laparotomy are not present. A case of major blunt hepatic injury in a 22-year-old patient is reported. The authors present a brief review of the literature and discussion about the role of CT scan in the evaluation of hepatic trauma, surgical planning and postoperative follow-up. (author). 15 refs., 3 figs., 1 tab

  19. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact.

    Science.gov (United States)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander; Lauridsen, Torsten; Hauge, Ellen-Margrethe; Jørgensen, Henrik L; Jørgensen, Niklas Rye; Feidenhansl, Robert; Pinholt, Else Marie

    2017-09-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone. The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT method, one histologic bone section is comparable to the 3D evaluation. Further, the two methods complement each other with knowledge on BIC in 2D and 3D. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Clinical evaluation of MRI for lumbar spinal disease

    International Nuclear Information System (INIS)

    Moriwaka, Yosuke; Nakayama, Sachiko; Murai, Nobuko; Watanabe, Katsushi; Kawano, Keiichiro; Tajima, Naoya; Kihara, Yasushi; Okada, Akihiko; Fujimoto, Toshiro.

    1985-01-01

    Thirty-two patients were examined to determine the clinical usefulness of magnetic resonance imaging (MRI) of the lumbar spine. MRI using a resistive magnet at 0.1 Tesla was compared with computed tomography (CT) and myelography. A saturation recovery (SR) technique with repetition time (TR) of 500 msec was used in all cases. There were 19 cases with disk herniation, 5 with canal stenosis, 2 with spondylosis deformans and 6 with other suspected disease. MRI showed the protrusion of disk, displacement of epidural fat and degenerative change of disk more clearly than CT and myelography. Of the 12 herniated disks, 8 disks were clearly shown and one was not detected by MRI. In some cases, herniated disk could not be differentiated from disk bulging. With further technical advance, MRI is likely to become the initial procedure for evaluation of lumbar spinal disease. (author)

  1. Evaluation of peripheral pulmonary perfusion decrease of 99m-Tc MAA scintigraphy using SPECT/CT

    International Nuclear Information System (INIS)

    Yoneyama, Tatsuya; Kamisaki, Yuichi; Kameda, Keisuke; Seto, Hikaru

    2012-01-01

    We often experienced non-segmented peripheral patchy decrease (NSPPD) in 99m Tc-macro-aggregated albumin (MAA) pulmonary perfusion scan using single photon emission computed tomography (SPECT)/CT. Seventy cases were evaluated by 99m Tc-MAA SPECT/CT. NSPPD was seen in 22 cases (31.4%), of which 17 were assessed for pulmonary hypertension. Pulmonary hypertension was diagnosed in 11 cases, which consisted of 3 chronic thromboembolic pulmonary hypertension, 2 idiopathic pulmonary arterial hypertension, 2 systemic lupus eryhthematosus and 4 left ventricular heart disease. We suggest that NSPPD may indicate the early stage of pulmonary hypertension (PH). (author)

  2. Evaluation of computer tomography in cerebro-vascular disease (Strokes)

    International Nuclear Information System (INIS)

    Lee, Young Sik; Baek, Seung Yon; Rhee, Chung Sik; Kim, Hee Seup

    1984-01-01

    Most of cerebrovascular disease are composed of vascular occulusive changes and hemorrhage. Now a day, the computed tomography is the best way for evaluation of cerebrovascular disease including detection of nature, location, and associated changes. This study includes evaluation of computed tomography of 70 patients with cerebrovascular disease during the period of 10 months from April. 1983 to Feb. 1984 in Department of Radiology, Ewha Womans University Hospital. The results were as follows: 1. Age distribution of the total 70 patients was broad ranging from 25 years to 79 years. 78.6% of patients were over the age of 50. The male and female sex ratio was 1.4:1. 2. 4 out of 70 patients were normal and 66 patients revealed abnormal on C.T. findings; those were intracranial hemorrhage (28 patients), cerebral infarction (34 patients) and brain atrophy (4 patients). 3. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (28 cases), and next was basal ganglia (2 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. 4. In cases of intracranial hemorrhage, the basal ganglia was most common site of lesion (15 cases). The next common site was cerebral hemisphere (9 cases). 6 patients of all intracranial hemorrhage were combined with intraventricular hemorrhage. Ratio of right and left was 2:3. 5. In patients with motor weakness or hemiparesis, more common findings on CT scan were cerebral infarction. In case with hemiplegia, more common CT findings were intracerebral hemorrhage. 6. Of the 40 cases thought to be cerebral infarction initially by clinical findings and spinal tap. 8 cases (20.0%) were proved to be cerebral hemorrhage by the CT scan. However, of the 22 cases thought to be cerebral hemorrhage, initially, only two cases (9.0%) were cerebral infarction

  3. Hypoxic-ischemic encephalopathy in neonates and infants: an evaluation with spiral CT

    International Nuclear Information System (INIS)

    Zhu Linghua

    2006-01-01

    Objective: To evaluate spiral CT imaging in the diagnosis of hypoxic-ischemic encephalopathy (HIE) in the neonates and infants. Methods: 112 children with history of asphyxia in peri-natal period and evident clinical symptoms were evaluated with Spiral CT. CT findings were studied. Results: 46 minor cases, 57 moderate cases and 9 severe cases were found out of 112 patients. Intracranial hemorrhage was revealed in 38 cases. Mortality occurred in 1 case. Conclusion: Spiral CT is helpful for evaluating brain damage and predicting prognosis in neonates with HIE. (authors)

  4. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  5. FDG PET-CT findings of extra-thoracic sarcoid are associated with cardiac sarcoid: A rationale for using FGD PET-CT for cardiac sarcoid evaluation.

    Science.gov (United States)

    Patel, Darshan C; Gunasekaran, Senthil S; Goettl, Christopher; Sweiss, Nadera J; Lu, Yang

    2017-07-05

    This retrospective study investigates the relationship between cardiac and extra-thoracic sarcoid findings on FDG PET-CT using a 72-hour pretest high-fat, high-protein, and very low-carbohydrate (HFHPVLC) diet. A total of 196 consecutive FDG PET-CT scans with 72-hour HFHPVLC diet preparation were performed between December 2014 and December 2015 in known sarcoid patients. Of these scans, 5 were excluded for non-adherence to diet preparation or underlying cancer. Cardiac and extra-thoracic sarcoid lesions were categorized and measured for radiotracer uptake. A total of 188 patients had 191 eligible FDG PET/CT scans (3 follow-up scans), of which there were 20 (10%) positive, 6 indeterminate (3%), and 165 (86%) negative for CS. Among the 20 scans positive for CS, 8 (40%) had findings of both cardiac and extra-thoracic sarcoid. Our study shows that 40% of CS patients also have FDG PET-CT findings of extra-thoracic sarcoid. This makes an intriguing case for FDG PET-CT use with pretest diet prep over cardiac MRI (CMR) for cardiac sarcoid evaluation, given that CMR is likely to overlook these extra-thoracic sites of disease.

  6. Pathophysiology of acute small bowel disease with CT correlation

    International Nuclear Information System (INIS)

    Sarwani, N.; Tappouni, R.; Tice, J.

    2011-01-01

    The objective of this article is to review the pathophysiology of acute small bowel diseases, and to correlate the mechanisms of disease with computed tomography (CT) findings. Disease entities will be classified into the following: immune mediated and infectious causes, vascular causes, mechanical causes, trauma, and others. Having an understanding of acute small bowel pathophysiology is a useful teaching tool, and can lead to imaging clues to the most likely diagnosis of acute small bowel disorders.

  7. Segmentation of Lung Structures in CT

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau

    This thesis proposes and evaluates new algorithms for segmenting various lung structures in computed tomography (CT) images, namely the lungs, airway trees and vessel trees. The main objective of these algorithms is to facilitate a better platform for studying Chronic Obstructive Pulmonary Disease......, 200 randomly selected CT scans were manually evaluated by medical experts, and only negligible or minor errors were found in nine scans. The proposed algorithm has been used to study how changes in smoking behavior affect CT based emphysema quantification. The algorithms for segmenting the airway...

  8. CT and ERCP diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Wang Dongfang; Cao Ran

    2003-01-01

    Objective: To evaluate some specific CT and ERCP findings for differentiating the nature of biliary obstructive diseases. Methods: In total 85 cases of obstructive jaundice verified by pathology were selected. The CT findings in 45 cases and ERCP features in 68 cases were retrospectively analyzed. Results: Mild dilatation of intrahepatic bile ducts were usually found in benign diseases, while moderately or severely dilated intrahepatic bile ducts were revealed in malignancies. Dilatation of intrahepatic bile ducts in vine pattern was one of the characteristic signs of malignant lesions, while 'withered branches' dilatation was usually found in benign diseases. Dilated extra-hepatic bile duct abruptly narrowed or obstructed was a typical finding in malignancies, while gradual tapering of common bile duct at the obstructed level usually indicated benign nature of the disease. Conclusion: Both CT and ERCP are valuable modalities in locating and differential diagnosis of biliary obstruction. A combined evaluation improves the accuracy of diagnosis

  9. Tomography high Resolution CT findings of nontuberculous mycobacterial pulmonary disease: Comparison between the first treatment and the re treatment group

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Soon Hyuk; Cho, Bum Sang; Jeon, Min Hee; Kim, Eun Young; Kang, Min Ho; Yi, Kyung Sik; Lee, Seung Young; Kim, Sung Jin; Lee, Ki Man [Chungbuk National Univ., Cheongju, (Korea, Republic of)

    2012-06-15

    To analyze and compare the thin section CT findings of first and re treatment nontuberculous mycobacterial (NTM) pulmonary disease. Between January 2005 and April 2010, 121 patients with positive sputum culture for NTM were recruited. We included only 32 patients underwent high resolution chest CT and were confirmed by American Thoracic Society criteria NTM pulmonary infection (first treatment 15, re treatment 17 patients). CT images of 32 patients were reviewed retrospectively. We evaluated the frequency and laterality of the followings; nodule, increased density, bronchial change, parenchymal change. The significantly frequent CT findings of the re treatment NTM group were well defined nodules (retreatment 82.4%, first treatment 33.3%, p = 0.00), consolidations (retreatment 88.2%, first treatment 53.3%, p = 0.03), bronchial changes (bronchiectasis; retreatment 100%, first treatment 66.6%, p = 0.01, bronchial narrowing; retreatment 23.5%, first treatment 0%, p = 0.04 and mucoid impaction; retreatment-58.8%, first treatment-20.0%, p = 0.03) and atelectasis with bronchiectasis (retreatment-88.2%, first treatment 26.7%, p = 0.00). However, most of the evaluated thin section CT findings, such as centrilobular and ill defined nodules, lobular, segmental and subpleural consolidations, ground glass attenuation, bronchial wall thickening, cavities, pleural lesions, fibrotic band, emphysema and laterality of lesions, have not shown significant differences between first treatment and the re treatment group. Thin section CT findings of well defined nodules, consolidations, bronchial changes (bronchiectasis, bronchial narrowing and mucoid impaction) and atelectasis with bronchiectasis are highly suggestive of re treatment NTM pulmonary disease.

  10. Chronic ankle instability: evaluation with stress radiography, CT and CT arthrography

    International Nuclear Information System (INIS)

    Faure, Ch.; Deplus, F.; Bochu, M.; Besse, J.L.; Moyen, B.

    1997-01-01

    We retrospectively evaluated the anterior talo-fibular ligament and the tarsal sinus of 17 patients who had complained of chronic ankle external instability. This study based on both surgery and CT-arthrography findings shows the pathologic or normal aspects of the talo-fibular anterior ligament (normal, lax, fibrosis residue, ruptured). It confirms the good anatomic analysis of the tarsal sinus, i particular the anterior talo-calcaneal interosseous ligament and the search for fibrosis. We underline that capsular distension due to subtalar laxity is not detected with medical imaging. Compared with surgery (all patients), CT arthrography demonstrated the different aspects of the anterior talo fibular ligament injuries (normal, lax, discontinuous). (authors)

  11. Weight preserving image registration for monitoring disease progression in lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Lo, Pechin Chien Pau; Haseem, Ashraf

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan...... the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans...

  12. Three-dimensional CT of the pediatric spine

    International Nuclear Information System (INIS)

    Starshak, R.J.; Crawford, C.R.; Waisman, R.C.; Sty, J.R.

    1987-01-01

    CT of the spine has been shown to be useful in evaluating congenital, neoplastic, inflammatory, and traumatic lesions. Any portion of the neural arch may be involved by these disease processes. The complex nature of the spinal column can make evaluation of these abnormalities difficult on axial CT. This is especially true if the spine is distorted by scoliosis, kyphosis, or lordosis. This exhibit illustrates the advantages and drawbacks of three-dimensional CT reconstructed images of spinal abnormalities in children

  13. Evaluation of Prostate Cancer Bone Metastases with 18F-NaF and 18F-Fluorocholine PET/CT.

    Science.gov (United States)

    Beheshti, Mohsen; Rezaee, Alireza; Geinitz, Hans; Loidl, Wolfgang; Pirich, Christian; Langsteger, Werner

    2016-10-01

    18 F-fluorocholine is a specific promising agent for imaging tumor cell proliferation, particularly in prostate cancer, using PET/CT. It is a beneficial tool in the early detection of marrow-based metastases because it excludes distant metastases and evaluates the response to hormone therapy. In addition, 18 F-fluorocholine has the potential to differentiate between degenerative and malignant osseous abnormalities because degenerative changes are not choline-avid; however, the agent may accumulate in recent traumatic bony lesions. On the other hand, 18 F-NaF PET/CT can indicate increased bone turnover and is generally used in the assessment of primary and secondary osseous malignancies, the evaluation of response to treatment, and the clarification of abnormalities on other imaging modalities or clinical data. 18 F-NaF PET/CT is a highly sensitive method in the evaluation of bone metastases from prostate cancer, but it has problematic specificity, mainly because of tracer accumulation in degenerative and inflammatory bone diseases. In summary, 18 F-NaF PET/CT is a highly sensitive method, but 18 F-fluorocholine PET/CT can detect early bone marrow metastases and provide greater specificity in the detection of bone metastases in patients with prostate cancer. However, the difference seems not to be significant. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Atherosclerotic stenoses of renal arteries: Evaluation with CT

    International Nuclear Information System (INIS)

    Marteau, V.; Melki, J.P.; DuTemple, C.; Despres, E.; Taieb, A.

    1987-01-01

    Recent reports have shown that the long-term results of transluminal angioplasty (PTA) in renal arteries, performed to treat renovascular hypertension resulting from atherosclerotic disease, depended on the location, extent, and consistency of the obstructing lesions. Therefore, 30 patients shown with arteriography to have 40 atherosclerotic stenoses and five occlusions of the renal artery underwent CT for study of the walls of the aorta and renal arteries. CT easily demonstrates atherosclerotic lesions and seems better than arteriography when the lesions are ostial. It shows whether stenoses are calcified and also defines the lesions of the abdominal aorta, which is helpful when surgical bypass is considered. The paper presents the authors' preliminary findings. Long-term follow-up of these patients show if CT has a predictive value about PTA results

  15. Thin-section CT of Cushing's disease

    International Nuclear Information System (INIS)

    Takahashi, Tatsuo; Kuwayama, Akio; Katoh, Tetsuo; Ichihara, Kaoru; Kageyama, Naoki; Nakamura, Koji.

    1983-01-01

    Using 1.5 mm contiguous sections with a GE CT/T 8800 scanner, we investigated the sellar regions of 22 cases of Cushing's diseases which had been diagnosed endocrinologically. Each sellar turcica was normal in size, and in only 5 cases were there significant findings on 2 mm-thick sellar-floor polytomography. Nine tumors appeared as regions of a hypodense area, and three tumors were diagnosed by indirect signs, for example, stalk deviation and diaphragmatic plane asymmetry. The other 10 cases, especially those previously operated on or irradiated, were diagnosed as falsely positive or negative. Because it is best of the microadenomas appear hypodense within the strongly contrast-enhanced anterior pituitary glands, it is better for scans to be obtained immediately after rapid intravenous contrast infusion. Hypodense areas of microadenomas are best demonstrated on direct coronal scans or reversed scans of 1.5 mm-thickness thin-slice sections. By these methods, microadenomas, if they are over 5-6 mm in diameter, can appear as hypodense. Sellar floor findings by means of thin-section CT were more sensitive than those of polytomography and had more advantages in local diagnosis. If the tumor were over 4 mm in diameter, local changes in the sellar floor could be demonstrated by thin-section CT, but by polytomography no changes in the sellar floor could be demonstrated until the tumor size reached 6 mm. (author)

  16. Primary pulmonary cryptococcosis: evaluation of CT characteristics in 26 immunocompetent Chinese patients

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Yanjuan; Liu, Guobing; Ghimire, Prasanna; Liao, Meiyan; Xu, Liying [Dept. of Radiology, Zhongnan Hospital of Wuhan Univ., Wuhan (China)], E-mail: leometeor123@gmail.com; Shi, Heshui [Dept. of Radiology, Union Hospital affiliated to Tongji Medical College of Huazhong Univ. of Science and Technology, Wuhan (China); Yang, Guifang [Dept. of Pathology, Zhongnan Hospital of Wuhan Univ., Wuhan (China); Wang, Guanliang [Dept. of Radiology, Taizhou Hospital of Zhejiang Province, Taizhou (China)

    2012-07-15

    Background. Discrepancies still exist in the diagnosis of primary pulmonary cryptococcosis in immunocompetent patients. Purpose. To describe and evaluate radiological manifestations of pulmonary cryptococcosis in immunocompetent patients. Material and Methods. Twenty-six histopathologically confirmed cases of pulmonary cryptococcosis were analyzed for clinical, pathological, and CT characteristics. Necessary statistical tests for differences in CT presentations and correlation analysis between clinical and CT characteristics were performed. Results. The patients' ages ranged from 24 to 79 years, with 20 men and six women. Eighteen patients were symptomatic, with cough as the most common symptom (n = 14, 53.8%). Nodules (n = 21, 80.8%) were the most common CT findings. Eight cases presented with solitary and nine with multiple nodules, while 13 cases presented with irregular and 19 with ill-defined nodules. The halo sign was demonstrated, encompassing nodules in 14 of the 21 patients. Lesions were mainly localized in the lower lobes of the lungs (n = 15, 57.7%) with peripheral distribution (n = 18, 69.2%). Ground-glass opacities (GGOs) were more easily detected in older patients (66.7%, P <0.01). No significant differences in CT abnormalities were found between male and female patients. Conclusion. Primary pulmonary cryptococcosis in immunocompetent patients exhibits certain CT characteristics. The typical presentation includes multiple nodules with the halo sign scattered in the peripheral field in the lower lobes of the bilateral lungs. This could contribute to diagnosis of the disease entity. However, vigilance should be exercised when facing GGOs, with or without nodules, in older patients.

  17. CT diagnosis of hepatic alveolar echinococcosis and evaluation after albendazole chemotherapy

    International Nuclear Information System (INIS)

    Wu Jingquan; Liu Yuehan; Wang Xiaogen

    1998-01-01

    Purpose: To analyze the CT features and evaluate albendazole chemotherapy of hepatic alveolar echinococcosis with computed tomography (CT). Methods: Twenty-one patients of hepatic alveolar echincoccosis were diagnosed by epidemiological, clinical, serological tests, and studied with US and CT. Twenty patients were followed up by CT scanning from 1 to 9 years (mean 3.9 years) after albendazole chemotherapy. Results: CT scanning of liver before treatment displayed heterogeneous hypodense lesions, with irregular, obscure contour and calcifications According to CT features, the hepatic lesions were divided into 3 forms: solid mass in 7 cases, pseudocyst in 6 cases and mixed in 8 cases. Three patients had contrast study. The hepatic lesions were not markedly enhanced, but the lesions were seen more clearly and appeared more extensive. In follow-up examination of 20 cases, 4 were apparently cured, 5 improved, 5 stabilized, and 6 cases remained pseudocyst. Conclusion: CT scanning was of value not only for diagnosis of hepatic alveolar echinococcosis, but also useful in evaluation of chemotherapeutic efficacy

  18. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  19. PET/CT for staging and follow-up of pediatric nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cheuk, Daniel K.L. [St Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); The University of Hong Kong, Department of Paediatrics and Adolescent Medicine, Pokfulam (China); Sabin, Noah D.; Hossain, Moinul; Krasin, Matthew J.; Shulkin, Barry L. [St Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); Wozniak, Amy [St Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); Naik, Mihir [St Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); University of Texas Health Science Center, Department of Radiation Oncology, San Antonio, TX (United States); Rodriguez-Galindo, Carlos [St Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); Hematology/Oncology, Dana-Farber Cancer Institute, Boston, MA (United States)

    2012-07-15

    While FDG PET/CT for the evaluation of nasopharyngeal carcinoma (NPC) in adult patients has documented advantages and disadvantages compared with conventional imaging, to our knowledge, no studies of FDG PET/CT for the evaluation of NPC in pediatric patients have been performed. In this investigation, we studied the utility of FDG PET/CT in children with NPC. The study group comprised 18 children with biopsy-proven NPC who underwent FDG PET/CT and MRI (total 38 pairs of images). All baseline and follow-up FDG PET/CT and MRI studies were independently reviewed for restaging of disease. The concordance between FDG PET/CT and MRI in T, N, and overall staging was 29%, 64%, and 43%, respectively. Compared with MRI, FDG PET/CT yielded lower T and overall staging and showed less cervical and retropharyngeal lymphadenopathy. The concordance between follow-up FDG PET/CT and MRI was 79% overall and 100% 9 months after therapy. In patients who achieved complete remission, FDG PET/CT showed disease clearance 3-6 months earlier than MRI. There were no false-positive or false-negative FDG PET/CT scans during follow-up. FDG PET/CT may underestimate tumor extent and regional lymphadenopathy compared with MRI at the time of diagnosis, but it helps to detect metastases and clarify ambiguous findings. FDG PET/CT is sensitive and specific for follow-up and enables earlier determination of disease remission. FDG PET/CT is a valuable imaging modality for the evaluation and monitoring of NPC in pediatric patients. (orig.)

  20. CT diagnosis in the evaluation of vertebral trauma

    International Nuclear Information System (INIS)

    Emori, Takumi; Kadoya, Satoru; Nakamura, Tsutomu; Ito, Shotaro; Kwak, Ryungchan

    1984-01-01

    The diagnostic capability of the CT scan of the vertebral trauma and a comparison with the results of a routine roentgenogram and tomogram were studied in 11 patients. In total, there were 15 fractured vertebrae: 3 in the upper cervical, 3 in the lower cervical, and 9 in the thoracic and thoraco-lumbar vertebrae. In the detailed evaluation of the vertebral fractures, CT provided more information than plain films in all 15 fractured vertebrae, with a better visualization of the spinal bony details, particularly at the upper cervical, thoracic, and thoraco-lumbar levels, where the interpretation of the spinal abnormalities is usually difficult because of adjacent structures such as the skull and thorax. Only CT was able to demonstrate impingements on the vertebral canal by bony fragments. Post-traumatic syringomyelia was incidentally demonstrated in one patient on a plain CT. In 6 patients, conventional tomography was done, but no additional information with regard to spinal instability and spinal-cord compression was obtained. The usage of sagittal tomography was also limited, because it required a change in the patient's position, which might worsen the neurological deficits. On the other hand, a plain roentgenogram and conventional tomography were superior in the evaluation of spinal malalignment and fractures running horizontally. In summary, both plain roentgenograms and CT images provided detailed information about vertebral injury, whereas conventional tomography is judged to be inferior and not always necessary. Based on these results, our new diagnostic and therapeutic approaches using CT for the vertebral injuries were presented. (author)

  1. Usefulness of {sup 131}I-SPECT/CT and {sup 18}F-FDG PET/CT in evaluating successful {sup 131}I and retinoic acid combined therapy in a patient with metastatics struma ovarii

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Lee, In Ki; Kang, Keon Wook; Lee, Dong Soo; Chung, June Key [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ryu, Young Hoon [Dept. of Nuclear Medicine, Yonsei University College of Medicine, Seoul (Korea, Republic of); Min, Hye Sook [Dept. of Pathology, Seoul National University Hospital, Seoul (Korea, Republic of); Lee, Dae Hee [Dept. of Oncology, GSAM Hosptial, Gunpo (Korea, Republic of)

    2015-03-15

    Metastatic struma ovarii is an extremely rare disease, and the treatment of choice has not been established. Here, we introduce the case of a 36-year-old female pregnant patient with metastatic struma ovarii. Initial treatment was an exploratory laparotomy to remove multiple peritoneal masses. After delivery, a total thyroidectomy was done for the further {sup 131}I-therapy. {sup 131}I-SPECT/CT and {sup 18}F-FDG PET/CT showed multiple hepatic metastases and extensive peritoneal seeding nodules. Multiple {sup 131}I and retinoic acid combination therapies were performed, resulting in marked improvement. {sup 131}I-SPECT/CT and {sup 18}F-FDG PET/CT were quite useful for evaluating the biologic characteristics of the metastase.

  2. Three-dimensional CT of the pediatric spine

    International Nuclear Information System (INIS)

    Starshak, R.J.; Crawford, C.R.; Waisman, R.C.; Sty, J.R.

    1987-01-01

    CT of the spine has been shown to be useful in evaluating congenital, neoplastic, inflammatory, and traumatic lesions. Any portion of the neural arch may be involved by these disease processes. However, the complex nature of the spinal column can make evaluation of these abnormalities difficult on axial CT. This is especially true if the spine is distorted by scoliosis, kyphosis, or lordosis. The principal advantage of three-dimensional CT is its ability to display the surface relationships of complicated objects. The complexity of the spinal axis makes it ideal for study with three-dimensional CT. This presentation illustrates the advantages and drawbacks of three-dimensional CT in spinal abnormalities in children

  3. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  4. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    International Nuclear Information System (INIS)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B.; Screaton, Nicholas J.

    2009-01-01

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  5. {sup 18}F{sub F}DG PET in evaluating malignancies compared with CT, MRI and pathology in 58 cases

    Energy Technology Data Exchange (ETDEWEB)

    Li, L. [Air Force General Hospital, Beijing (Switzerland)

    2000-07-01

    This article discussed the practical application of {sup 18}F-FDG PET imaging techniques to depict, state, or define recurrences for five important malignancies: lung cancer, colorectal and head-and-neck cancer, intracranial malignant glioma and primary or secondary hepatic malignant diseases. And comparisons of {sup 18}F-FDG PET with CT, MRI imaging were addressed specifically. We reviewed our initial experience with 48 malignant and ten non-malignant cases. Among malignant group, 36 cases were confirmed by operation or biopsy, Other ten non-malignant diseases, including brain infarction, post-radiotherapy necrosis or scar and lung abscesses were followed with CT or MRI at least 6 months. All patients received intravenous administration of {sup 18}F-FDG 10-15 mCi, followed by a 40 minutes uptake phase, and subsequent imaged using a Siemens ECAT 931 whole-body scanner with resolution of 4 mm FWHM in the center of the field of view. Filtered back projection reconstruction was used to display attenuated or non-attenuated corrected images. The result of {sup 18}F-FDG PET was retrospectively evaluated to assess the degree of uptake of {sup 18}F-FDG PET in the tumor tissues and compared with CT, MRI and pathology. CT and MRI exam were taken before or after PET study in two weeks. {sup 18}F-FDG PET scans showed a significantly increased FDG metabolism in 47 malignant lesions, The tumor / normal tissue FDG uptake rate were 4.16 {+-}2.11. In 47 cases with neoplasm, {sup 18}F-FDG PET findings were constant with or further confirmed the CT or MRI diagnosis in 35/47 (74.5%) and 12/47 (253%) cases. Another one small intracranial metastasis (<0,6cm), shown on contrast MRI was not displayed by glucose metabolism Otherwise, the tumor/normal tissue FDG uptake rate were 0.86 {+-} 1,46 in ten non-malignant cases. Most of post-radiotherapy cerebral necrosis, which can't be distinguished on both contrast CT and MRI, showed FDG uptake defect. One cerebral infarction, previously

  6. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  7. Quantifying the usefulness of CT in evaluating seniors with abdominal pain

    International Nuclear Information System (INIS)

    Lewis, Lawrence M.; Klippel, Allen P.; Bavolek, Rebecca A.; Ross, Laura M.; Scherer, Tara M.; Banet, Gerald A.

    2007-01-01

    Objectives: (1) Determine if older patients with abdominal pain who receive emergency department (ED) abdominal CT have changes in diagnosis and/or disposition more often than similar patients without CT; (2) compare physician confidence in diagnosis and disposition for patients with versus without CT; (3) document factors that most influence physician's decision to order abdominal CT in this population. Methods: ED patients 60 years of age or older, with acute non-traumatic abdominal pain were enrolled over a 6-week period. Physicians documented a preliminary and final ED diagnosis and disposition, along with pre- and post-evaluation confidence levels. Decision to order CT, along with clinical information most influencing that decision, was noted. Physician confidence levels and percent change in diagnosis and disposition were compared for patients with versus without CT. Results: One hundred and twenty-six patients comprised study sample. Abdominal CT rate was 59% (95%CI, 50-67%). CT was associated with an increased change in diagnosis (46%; 95%CI, 4-58% versus 29%; 95%CI, 16-42%), but no change in disposition between patients with versus without CT. Preliminary diagnostic confidence was lower for EPs who ordered a CT than for those who did not (p < 0.001). Patient history most influenced ordering CT, whereas prior lab/imaging results most influenced not ordering CT. Conclusion: Patients with CT had a change in diagnosis more often than those without. Preliminary diagnostic confidence was lower in CT group. Percent change in disposition did not differ between groups. Physicians most often ordered CT based on history and did not order CT when other diagnostic evaluation supported a specific diagnosis

  8. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  9. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  10. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  11. PET/CT imaging in response evaluation of patients with small cell lung cancer

    DEFF Research Database (Denmark)

    Fischer, Barbara M; Mortensen, Jann; Langer, Seppo W

    2006-01-01

    UNLABELLED: There is an increasing amount of evidence on the usability of PET in response evaluation of non-small cell lung cancer. However, data on SCLC is scarce and mainly retrospective. This prospective study assesses the use of PET (positron emission tomography) and PET/CT in response...... evaluation of patients with small cell lung cancer (SCLC). METHODS: Assignment of early and final response was compared between PET, PET/CT, and CT in 20 patients with SCLC. Final response as assigned by CT (RECIST) served as reference. RESULTS: At response evaluation after one cycle of chemotherapy major...... by PET/CT is feasible, but it is uncertain whether it adds further information to evaluation by RECIST, thus further studies and standardization of methods are needed....

  12. FDG-PET/CT in the evaluation of anal carcinoma

    International Nuclear Information System (INIS)

    Cotter, Shane E.; Grigsby, Perry W.; Siegel, Barry A.

    2006-01-01

    Purpose: Surgical staging and treatment of anal carcinoma has been replaced by noninvasive staging studies and combined modality therapy. In this study, we compare computed tomography (CT) and physical examination to [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) in the staging of carcinoma of the anal canal, with special emphasis on determination of spread to inguinal lymph nodes. Methods and Materials: Between July 2003 and July 2005, 41 consecutive patients with biopsy-proved anal carcinoma underwent a complete staging evaluation including physical examination, CT, and 2-FDG-PET/CT. Patients ranged in age from 30 to 89 years. Nine men were HIV-positive. Treatment was with standard Nigro regimen. Results: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) detected 91% of nonexcised primary tumors, whereas CT visualized 59%. FDG-PET/CT detected abnormal uptake in pelvic nodes of 5 patients with normal pelvic CT scans. FDG-PET/CT detected abnormal nodes in 20% of groins that were normal by CT, and in 23% without abnormality on physical examination. Furthermore, 17% of groins negative by both CT and physical examination showed abnormal uptake on FDG-PET/CT. HIV-positive patients had an increased frequency of PET-positive lymph nodes. Conclusion: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography detects the primary tumor more often than CT. FDG-PET/CT detects substantially more abnormal inguinal lymph nodes than are identified by standard clinical staging with CT and physical examination

  13. Imaging fusion (SPECT/CT) in degenerative disease of spine

    International Nuclear Information System (INIS)

    Bernal, P.; Ucros, G.; Bermudez, S.; Ocampo, M.

    2007-01-01

    Full text: Objective: To determine the utility of Fusion Imaging SPECT/CT in degenerative pathology of the spine and to establish the impact of the use of fusion imaging in spinal pain due to degenerative changes of the spine. Materials and methods: 44 Patients (M=21, F=23) average age of 63 years and with degenerative pathology of spine were sent to Diagnosis Imaging department in FSFB. Bone scintigraphy (SPECT), CT of spine (cervical: 30%, Lumbar 70%) and fusion imaging were performed in all of them. Bone scintigraphy was carried out in a gamma camera Siemens Diacam double head attached to ESOFT computer. The images were acquired in matrix 128 x 128, 20 seg/imag, 64 images. CT of spine was performed same day or two days after in Helycoidal Siemens somatom emotion CT. The fusion was done in a Dicom workstation in sagital, axial and coronal reconstruction. The findings were evaluated by 2 Nuclear Medicine physicians and 2 radiologists of the staff of FSFB in an independent way. Results: Bone scan (SPECT) and CT of 44 patients were evaluated. CT showed facet joint osteoarthrities in 27 (61.3%) patients, uncovertebral joint arthrosis in 7 (15.9%), bulging disc in 9(20.4%), spinal nucleus lesion in 7(15.9%), osteophytes in 9 (20.4%), spinal foraminal stenosis in 7 (15.9%), spondylolysis/spondylolisthesis in 4 (9%). Bone scan showed facet joint osteoarthrities in 29 (65.9%), uncovertebral joint arthrosis in 4 (9%), osteophytes in 9 (20.4%) and normal 3 (6.8%). The imaging fusion showed coincidence findings (main lesion in CT with high uptake in scintigraphy) in 34 patients (77.2%) and no coincidence in 10 (22.8%). In 15 (34.09%) patients the fusion provided additional information. The analysis of the findings of CT and SPECT showed similar results in most of the cases and the fusion didn't provide additional information but it allowed to confirm the findings but when the findings didn't match where the CT showed several findings and SPECT only one area with high uptake

  14. Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer

    Directory of Open Access Journals (Sweden)

    Saima Riaz

    2017-06-01

    Full Text Available Objective(s: Small cell lung cancer (SCLC is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM staging of SCLC, compared to the conventional computed tomography (CT scan and its potential role as a prognosticator.Methods: This retrospective review was conducted on 23 patients, who were histopathologically diagnosed to have SCLC and referred for undergoing 18F-FDG PET/CT scanning during October 2009-December 2015. The rate of agreement between the CT and 18F-FDG PET/CT findings for TNM staging was calculated using the Cohen’s kappa (κ. The median follow-up time was eight months, ranging 27-3 months. The overall and disease-free survival rates were calculated based on the extent of disease.Results: 19 cases were male and four female with the mean age of 58±9 years. The 18F-FDG PET/CT identified limited and extensive diseases in 2 (8.7% and 21 (91.3% patients, respectively. In addition, the results of the Cohen’s kappa demonstrated a strong (κ=0.82, fair (κ=0.24, and poor (κ=0.12 agreement between the PET/CT and CT findings for determining tumor, node, and metastasis stages, respectively. The 18F-FDG PET/CT scans upstaged disease in 47% of the cases with visceral and osseous metastasis. The disease-free survival rates for the limited and extensive diseases were 100% and 23% within the 12-month follow-up. In addition, 8 (35% patients expired during the follow-up period.Conclusion: Improved nodal and metastatic disease identification highlights the role of 18F-FDG PET/CT scanning in initial staging of SCLC with prognostic implications.

  15. Evaluation of clinical efficacy of transrectal sonography and computed tomography for prostatic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroki; Ohe, Hiroshi; Tanahashi, Toshikatsu and others

    1988-07-01

    Receiver operating characteristics (ROC) analysis was performed to evaluate the clinical efficacy of transrectal sonography (US) and computed tomography (CT) for prostatic diseases. One hundred US and CT images of prostatic diseases collected from 10 medical institutions, including 33 cases of prostatic cancer, 29 of benign prostatic hypertrophy, 7 of prostatitis, 2 of prostatic stone and 29 of normal finding, were read by 21 urologists. As the results, US was found to be more useful than CT for both the detection of prostatic diseases and the differentiation between prostatic cancer and benign prostatic hypertrophy. The sensitivity of US for the diagnosis of prostatic cancer was 64.2 % on average of all the urologists. However, the sensitivity was 80.0 % on average of 5 urologists who have read more than 3,000 US images and 59.5 % on average of 16 doctors who have read within 3,000 US images.

  16. Evaluation of solitary pulmonary nodules by integrated PET/CT: improved accuracy by FDG uptake pattern and CT findings

    International Nuclear Information System (INIS)

    Joon Young Choi; Kyung Soo Lee; O Jung Kwon; Young Mog Shim; Kyung-Han Lee; Yong Choi; Yearn Seong Choe; Byung-Tae Kim

    2004-01-01

    Objective: FDG PET is useful to differentiate malignancy from benign lesions in the evaluation of solitary pulmonary nodules (SPNs). However, FDG PET showed false positive results in benign inflammatory lesions such as tuberculosis and organizing pneumonia. Furthermore, malignant tumors such as adenocarcinoma (AC) with bronchioloalveolar carcinoma (BAC) type had lower FDG uptake than other cell types of non-small cell lung cancer. We investigated whether FDG uptake pattern and image findings of CT for attenuation correction could improve accuracy for evaluating SPNs over SUV in integrated PET/CT imaging using FDG. Methods: Forty patients (M:F = 23:17, mean age 58.2±9.4 yrs) with non-calcified SPNs (diameter on CT 30 mm, no significant mediastinal node enlargement, no atelectasis) were included. All subjects underwent integrated PET/CT imaging using FDG. One nuclear medicine physician and 1 chest radiologist interpreted the PET and non-contrast CT images for attenuation correction, respectively. On PET images, maximum SUV of SPN was acquired, and FDG uptake pattern was categorized as diffusely increased or heterogeneously increased with upper threshold of window setting adjusted to maximum SUV of each nodule. A radiologist interpreted SPNs as benign or malignant based on CT images with lung and mediastinai window settings blinded to PET findings. Results: On pathological exam, 30 SPNs were confirmed to be malignant (11 AC with non-BAC type, 8 AC with BAC type, 8 squamous cell carcinoma, 1 adenosquamous cell carcinoma, 1 neuroendocrine carcinoma, 1 large cell carcinoma), and 10 were benign (4 tuberculosis, 3 organizing pneumonia, 2 sclerosing pneumocytoma, 1 non-specific inflammation). All 5 nodules with max SUV 7.0 except one with tuberculoma had malignancy. When only nodules with diffusely increased uptake were considered malignant in indeterminate group with max SUV of 4.0 to 7.0, PET could diagnose 5 of 9 malignant nodules with one false positive nodule. In 6 of

  17. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  18. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Funama, Yoshinori

    2011-01-01

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 ± 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m 2 ) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 2 at baseline was high in patients with advanced age, CVD and DM and in patients without oncologic disease

  19. Characterizing IgG4-related disease with 18F-FDG PET/CT: a prospective cohort study

    International Nuclear Information System (INIS)

    Zhang, Jingjing; Ma, Yanru; Niu, Na; Wang, Xinwei; Li, Fang; Zhu, Zhaohui; Chen, Hua; Lin, Wei; Zhang, Fengchun; Zhang, Wen; Xiao, Yu; Liang, Zhiyong

    2014-01-01

    IgG4-related disease (IgG4-RD) is an increasingly recognized clinicopathological disorder with immune-mediated inflammatory lesions mimicking malignancies. A cohort study was prospectively designed to investigate the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in characterizing IgG4-RD. Thirty-five patients diagnosed with IgG4-RD according to the consensus criteria were enrolled with informed consent. All patients underwent baseline 18 F-FDG PET/CT evaluation. Among them, 29 patients underwent a second 18 F-FDG PET/CT scan after 2 to 4 weeks of steroid-based therapy. All 35 patients were found with 18 F-FDG-avid hypermetabolic lesion(s); 97.1 % (34/35) of these patients showed multi-organ involvement. Among the 35 patients, 71.4 % (25/35) patients were found with more organ involvement on 18 F-FDG PET/CT than conventional evaluations including physical examination, ultrasonography, and computed tomography (CT). 18 F-FDG PET/CT demonstrated specific image characteristics and pattern of IgG4-RD, including diffusely elevated 18 F-FDG uptake in the pancreas and salivary glands, patchy lesions in the retroperitoneal region and vascular wall, and multi-organ involvement that cannot be interpreted as metastasis. Comprehensive understanding of all involvement aided the biopsy-site selection in seven patients and the recanalization of ureteral obstruction in five patients. After 2 to 4 weeks of steroid-based therapy at 40 mg to 50 mg prednisone per day, 72.4 % (21/29) of the patients showed complete remission, whereas the others exhibited > 81.8 % decrease in 18 F-FDG uptake. F-FDG PET/CT is a useful tool for assessing organ involvement, monitoring therapeutic response, and guiding interventional treatment of IgG4-RD. The image pattern is suggested to be updated into the consensus diagnostic criteria for IgG4-RD. (orig.)

  20. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    International Nuclear Information System (INIS)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease. (author)

  1. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease.

  2. A pilot study of three dimensional color CT images of brain diseases to improve informed consent

    International Nuclear Information System (INIS)

    Tanizaki, Yoshio; Akiyama, Takenori; Hiraga, Kenji; Akaji, Kazunori

    2005-01-01

    We have described brain diseases to patients and their family using monochrome CT images. It is thought that patients have difficulties in giving their consent to our conventional explanation because their understanding of brain diseases is based on three dimensional and color images, however, standard CT images are two dimensional and gray scale images. We have been trying to use three dimensional color CT images to improve the typical patient's comprehension of brain diseases. We also try to simulate surgery using these images. Multi-slice CT accumulates precise isotropic voxel data within a half minute. These two dimensional and monochrome data are converted to three dimensional color CT images by 3D workstation. Three dimensional color CT images of each brain structures (e.g. scalp, skull, brain, ventricles and lesions) are created separately. Then, selected structures are fused together for different purposes. These images are able to rotate around any axis. Because the methods to generate three-dimensional color images have not established, we neurosurgeons must create these images. In particular, when an operation is required, the surgeon should create the images. In this paper, we demonstrate how three-dimensional color CT images can improve informed consent. (author)

  3. Basic principles of pulmonary anatomy and physiology for CT interpretation of lung diseases

    International Nuclear Information System (INIS)

    Remy-Jardin, M.; Beigelman, C.; Desfontaines, C.; Dupont, S.; Remy, J.

    1989-01-01

    High resolution CT is now the method of choice in the diagnosis of lung diseases, especially in their early recognition. However, the radiologist must be aware of precise anatomic, pathologic and physiologic data which are observed when the patient is supine. This concept leads to a transversal analysis of lung diseases by CT, as previously proposed in the coronal and sagittal planes for conventional chest X Ray interpretation. The aim of the study is to demonstrate that these regional differences in the lung must be included in the method of chest scanning but also in the interpretation of lung diseases [fr

  4. Atheromatous extracranial carotid arteries: CT evaluation correlated with arteriography and pathologic examination

    International Nuclear Information System (INIS)

    Leeson, M.D.; Cacayorin, E.D.; Iliya, A.R.; Hodge, C.J.; Culebras, A.; Collins, G.H.; Kieffer, S.A.

    1985-01-01

    Dynamic, rapid sequence, axial computed tomography (CT) was employed to evaluate the extracranial common and internal carotid arteries in 17 patients with clinical histories suggesting recent or remote ischemia in the territory supplied by the internal carotid artery. The CT findings were correlated with arteriographic observations and with gross and histologic evaluations of endarterectomy specimens. Areas of arterial wall thickening were evaluated on CT scans with regard to both degree of thickening and radiographic density (attenuation). The degree of vessel wall thickening secondary to atheromatous plaque demonstrated on CT scans corresponded closely to the severity of luminal compromise seen on arteriograms. While arteriography provides information regarding the status of the arterial lumen, CT offers the potential of accurate characterization of pathologic changes in the wall of the extracranial carotid arteries in patients with symptoms of cerebral ischemia

  5. CT-guided unilateral thalamotomy with macroelectrode mapping for the treatment of Parkinson's disease

    International Nuclear Information System (INIS)

    Valalik, I.; Julow, J.; Sagi, S; Solymosi, D.

    2001-01-01

    Objective. To evaluate the effect of unilateral thalamotomy in patients with Parkinson's disease. Methods. The junction of the ventralis oralis posterior and ventralis intermedius nuclei targeted under CT-guidance, and confirmed by impedance recording and macrostimulation. Results. At the 6-month assessment the tremor has been completely abolished in 37 patients (82.2 %), and reduced in 6 patients (13.3 %). The unified Parkinson's disease rating scale tremor score decreased by 92.5 %, rigidity improved by 65.9 %. Axial symptoms and bradykinesia showed smaller improvement. The levodopa and anti-cholinergic medication significantly reduced. An improvement in the quality of life measured by the Parkinson's disease questionnaire (PDQ-39) has been observed. The dimensions of mobility, activities of daily living, emotional well being, and Stigma were significantly (P < 0.05) better, other changes were not significant. The single index improved from 47.8 ± 7.8 to 28.9 ± 6.3. Transient complications noted in 9 patients (20 %), mild persistent morbidity observed in 3 patients (6.7 %). At the 1, 2 and 3-year follow-up neither contralateral tremor, rigidity, nor bradykinesia progression was statistically significant. Conclusions. CT-guided thalamotomy with macro-electrode mapping provides a safe, effective and long lasting control of tremor and rigidity, reduces the need for medication, and improves the quality of life. (author)

  6. Performance evaluation of 8 CT scanners for clinical use in Italy

    International Nuclear Information System (INIS)

    Pinto, I.; De Denaro, M.; Giribona, P.; Gicericin, C.; Bravar, D.

    1988-01-01

    In the past few years the use of CT scanners has widely spread in Italian care institutions. This methodology has thus become an important creates the need for an accurate study of the various aspects of the phenomenon, e.g. technological, diagnostic and economic. In order to evaluate the quality of the CT scanners used in our country, the majors suppliers of the Italian market were asked to provide us with a unit from their production. Six out of 7 companies complied with our request. A standard protocol was used to evaluate the performance of 8 CT scanners, currently used in Italy. The following parameters were evaluated: spatial resolution, contrast resolution, noise, slice thickness, uniformity, linearity and radiation dose. Five currently-used operating modalities were employed. The results allow an overall assessment of the performance of the 8 CT scanners

  7. CT imaging of hepatic veno-occlusive disease (an analysis 14 cases)

    International Nuclear Information System (INIS)

    Zhang Guohua; Kong Azhao; Fang Junwei; Chen Yuejing; Zheng Weiliang; Dong Danjun; Zhang Shizheng

    2006-01-01

    Objective: To probe imaging characteristics of the hepatic veno-occlusive disease (VOD) based on clinical features and abdomen CT findings. Methods: Fourteen patients including 6 male and 8 female aged from 41 to 73 years were enrolled in this study. They all had previous trauma history and notoginseng was given as herbal remedy. Dynamic enhanced CT and color Dopplor ultrasound examinations were routinely used. Two of them received venous angiography and four cases were pathologically proved as VOD after CT guided needle biopsy. Results: Hepatic swelling and ascites were found on plain CT scan. Diffuse patchy areas without enhancement indicative of poorly hepatic perfusion were found. Hepatic veins were compressed and became thin, and inferior vena cava was flat and narrow without distal dilation or collateral circulation. No obstruction of hepatic veins and inferior vena cava was found on ultrasound and venography. Conclusion: Dynamic enhanced CT is highly valuable for early assessing VOD and imaging features of venous hepatic congestion found on CT was strongly suggestive of VOD if there's previous history of treatment of gynura segetum. (authors)

  8. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  9. PET/CT versus bone marrow biopsy in the initial evaluation of bone marrow infiltration in various pediatric malignancies.

    Science.gov (United States)

    Zapata, Claudia P; Cuglievan, Branko; Zapata, Catalina M; Olavarrieta, Raquel; Raskin, Scott; Desai, Kavita; De Angulo, Guillermo

    2018-02-01

    Accurate staging is essential in the prognosis and management of pediatric malignancies. Current protocols require screening for marrow infiltration with bone marrow biopsy (BMB) as the gold standard. Positron emission tomography-computed tomography (PET-CT) is commonly used to complete the staging process and can also be used to evaluate marrow infiltration. To compare PET-CT and BMB in the initial evaluation of bone marrow infiltration in pediatric cancers. We retrospectively reviewed new cases of EWS, rhabdomyosarcoma, neuroblastoma, and lymphoma diagnosed between January 2009 and October 2014. Each case had undergone both PET-CT and BMB within 4 weeks without treatment in the interval between screening modalities. We reviewed 69 cases. Bone marrow infiltration was demonstrated in 34 cases by PET-CT and in 18 cases by BMB. The sensitivity and negative predictive value of PET-CT were both 100%. Interestingly, the cases in which infiltration was not detected on BMB had an abnormal marrow signal on PET-CT focal or distant to iliac crest. PET-CT has a high sensitivity when assessing marrow infiltration in pediatric malignancies. Advances in radiologic modalities may obviate the use of invasive, painful, and costly procedures like BMB. Furthermore, biopsy results are limited by insufficient tissue or the degree of marrow infiltration (diffuse vs. focal disease). PET-CT can improve the precision of biopsy when used as a guiding tool. This study proposes the use of PET-CT as first-line screening for bone marrow infiltration to improve the accuracy of staging in new diagnoses. © 2017 Wiley Periodicals, Inc.

  10. FDG-PET/CT in autosomal dominant polycystic kidney disease patients with suspected cyst infection.

    Science.gov (United States)

    Pijl, Jordy Pieter; Glaudemans, Andor W J M; Slart, Riemer H J A; Kwee, Thomas Christian

    2018-04-13

    Purpose: To determine the value of 18 F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) for diagnosing renal or hepatic cyst infection in patients with autosomal dominant polycystic kidney disease (ADPKD). Methods: This retrospective single-center study included all patients with ADPKD who underwent FDG-PET/CT because of suspected cyst infection between 2010 and 2017. Results: Thirty FDG-PET/CT scans of thirty individual patients were included, of which 19 were positive for cyst infection. According to a previously established clinical and biochemical reference standard, FDG-PET/CT achieved sensitivity of 88.9%, specificity of 75.0%, positive predictive value of 84.2%, and negative predictive value of 81.8% for the diagnosis of cyst infection. In 5 cases, FDG-PET/CT suggested a different pathologic process that explained the symptoms, including pneumonia ( n = 1), generalized peritonitis ( n = 1), pancreatitis ( n = 1), colitis ( n = 1), and cholangitis ( n = 1). Total duration of hospital stay and duration between FDG-PET/CT scan and hospital discharge of patients with an FDG-PET/CT scan positive for cyst infection were significantly longer than those with a negative scan ( P = 0.005 and P = 0.009, respectively). Creatinine levels were significantly higher in patients with an FDG-PET/CT scan positive for cyst infection than in patients with a negative scan ( P = 0.015). Other comparisons of clinical parameters (age, gender, presence of fever (>38.5°C) for more than 3 days, abdominal pain, history of solid organ transplantation and nephrectomy, immune status), laboratory values (C-reactive protein level (CRP), leukocyte count, estimated glomerular filtration rate), and microbiologic results (blood and urine cultures) were not significantly different ( P = 0.13-1.00) between FDG-PET/CT-positive and -negative patients. Conclusion: FDG-PET/CT is a useful and recommendable (upfront) imaging modality for the evaluation of

  11. Thin-section CT imaging that correlates with pulmonary function tests in obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki, E-mail: arakawa@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine (Japan); Fukushima, Yasutugu [Department of Pulmonary Medicine and Clinical Immunology, Dokkyo Medical University (Japan); Kaji, Yasushi [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)

    2011-11-15

    Purpose: The purpose of this study was to identify independent CT findings that correlated with pulmonary function tests (PFTs) in patients with obstructive airway diseases. Materials and methods: Sixty-eight patients with obstructive airway disease and 29 normal subjects (mean age, 52 years; 36 men and 61 women) underwent inspiratory and expiratory thin-section CT and PFTs. Patient with obvious emphysema was excluded. Two radiologists independently reviewed the images and semi-quantitatively evaluated lung attenuation (mosaic perfusion, air trapping) and airway abnormalities (extent and severity of bronchial wall thickening and bronchiectasis, bronchiolectasis or centrilobular nodules, mucous plugging). Univariate, multivariate and receiver operating characteristic (ROC) analyses were performed with CT findings and PFTs. Results: Forty-two patients showed obstructive PFTs, 26 symptomatic patients showed near-normal PFTs. On univariate analysis, air trapping and bronchial wall thickening showed highest correlation with obstructive PFTs such as FEV1.0/FVC, MMEF and FEF75 (r ranged from -0.712 to -0.782; p < 0.001), while mosaic perfusion and mucous plugging showed moderate correlation, and bronchiectasis, bronchiolectasis and nodules showed the least, but significant, correlation. Multiple logistic analyses revealed air trapping and bronchial wall thickening as the only significant independent determinants of obstructive PFTs. ROC analysis revealed the cut-off value of air trapping for obstructive PFTs to be one-third of whole lung (area under curve, 0.847). Conclusions: Our study confirmed air trapping and bronchial wall thickening are the most important observations when imaging obstructive PFTs. The cut-off value of air trapping for identifying obstructive PFTs was one-third of lung irrespective of inspiratory CT findings.

  12. Evaluation of anemia on unenhanced CT of the thorax

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Zhang Xuelin; Zhong Qun; Zhang Fan; Zhang Wensheng

    2006-01-01

    Objective: To explore the correlation between CT density of blood in Cardiac Chambers and hemoglobin concentration in blood, and to evaluate the veracity of diagnosis of aneamia on unenhanced computed tomography of the thorax. Methods: Thorax (heart) helical CT was performed in 92 patients. In each case, the CT values of the blood pool in left ventricle and ventricular septum were tested, and the ratio of blood pool/ventricular septum were calculated. The hemoglobin concentration in blood was tested. The correlation among these indexes were analysed. Results: In these factors, CT density of blood was strongly and positively correlated with hemoglobin concentration in blood (r=0.571, P=0.000), and the CT density ratio was also strongly and positively correlated with hemoglobin concentration in blood (r=0.650, P=0.000). It dramatically implies that the patient may be suffering from aneamia when the ratio is Ness than 90% (male) or 87% (female). Conclusion: Blood pool/ventricular septum CT density ratio may be as a reliable indicator for judging and grading aneamia with CT. (authors)

  13. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    Science.gov (United States)

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (Pdynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  14. Diagnosis of gynecologic pelvic masses by CT scans

    International Nuclear Information System (INIS)

    Ito, Hisao; Kubo, Atsushi; Takagi, Yaeko; Kinoshita, Fumio; Maekawa, Akira.

    1981-01-01

    Two hundred eighty four patients with gynecologic pelvic masses were evaluated with CT scans. Of the patients, 196 had subsequent surgical determination of abnormalities and pathological proof of diagnosis was obtained. Only these 196 patients were included in this study. The CT scans could provide correct diagnosis in 113 of 114 (99%) patients with benign uterine tumor and in all (100%) patients with either serous cystadenoma or dermoid cyst. However, evaluation of mucinous cystadenoma (44%) and endometriosis cyst (37%) by CT scan has some limitations. It was difficult to differentiate mucinous cystadenoma from ovarian carcinoma, because both lesions had partial multiloculation and solid-like areas in the cyst. The CT findings of endometriosis cyst had similarity with serous cystadenoma, and 5 of 8 patients with this disease were diagnosed as serous cystadenoma. Ovarian fibroma and endometrial cancer were also not determined by CT scans. CT identified 87% of patients with ovarian cancer, while false positive rate of this disease was 38% (8/21). In 6 of 13 patients with both of leiomyoma and ovarian cyst, CT was able to demonstrate ovarian lesions that were overlooked by bimanual examinations. The role of CT scanning in our clinical practice is discussed. (author)

  15. Acute pancreatitis: staging with CT

    International Nuclear Information System (INIS)

    Gialeli, E.; Petrocheilou, G.; Georgaki, S.; Tzemailas, I.; Adraktas, A.; Charilas, G.; Patsiogiannis, V.

    2012-01-01

    Full text: Introduction: Computed Tomography (CT) is the imaging modality of choice for the diagnosis and staging of acute pancreatitis and its complications. Objectives and tasks: The purpose of this presentation is to demonstrate the findings in CT images which are useful for staging acute pancreatitis according to Balthazar, their significance and restrictions. Materials and methods: CT images from patients who were referred to our Department for an abdominal CT scan for the diagnosis or/and staging of acute pancreatitis were retrospectively studied. Results: In acute pancreatitis, CT helps to stage the severity of inflammatory process, to detect pancreatic necrosis and to depict local complications. CT severity index (CTSI), which was proposed by Balthazar et al, combines the grade of pancreatitis with the extent of pancreatic necrosis assigning points to the patients in order to find the severity index which scales from 0-10. More points are given for a higher grade of pancreatitis and for more extensive necrosis. Types of pancreatitis according to CTSI are: interstitial (Balthazar grade A-C), exudative (Balthazar grade D or E), necrotising (Balthazar grade E, CTSI:10) and central gland necrotising. Patients with pancreatitis but no collections or necrosis have an interstitial (mild) pancreatitis. In exudative pancreatitis there is normal enhancement of the entire pancreas associated with extensive peripancreatic collections. Necrotizing (severe) pancreatitis is characterized by protacted clinical course, high incidence of local complications and high mortality rate. Central gland necrosis is a subtype of necrotizing pancreatitis. Conclusions: The combination of CT imaging and clinical and laboratory evaluation allows the early diagnosis of acute pancreatitis. Acute pancreatitis may vary from a mild uneventful disease to a severe life-threatening illness with multisystemic organ failure. Thus, it is crucial to identify patients who are at high risk of severe

  16. Spinal CT scan, 1. Cervical and thoracic spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ. (Japan))

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections.

  17. Retroperitoneal Castleman's disease: US, CT and MRI findings

    International Nuclear Information System (INIS)

    Bonini, Claudio; Boretti, Juan J.; Villavicencio, Roberto; Oxilia, Hector; Costamagna, Cecilia; Ferrer, Jaime; Secchi, Mario

    2003-01-01

    Purpose: To describe de imaging features of this unusual localization of Castleman's disease. Materials and methods: Two patients (man: 62 years old, woman: 27 years old) with epigastric abdominal pain were studied. The physical examination was negative in the woman while in the other case a peri umbilical tumor was observed. The laboratory and the tumor markers were negative. Both patients had a history of appendectomy. US, TC and MRI were performed. After surgery the pathological examination included stain techniques with hematoxylin-eosin, Masson's techniques and PAS. Results: Retroperitoneal Castleman's disease in peri pancreatic localization (extremely rare). The US showed slight hypoechoic homogeneous lesions with clear rims. CT without contrast revealed isodense lesions and one of them presented a small calcification, the e.v. contrast CT showed a clear homogeneous reinforcement. MRI demonstrated hypointense lesions on T1, hyperintense on T2, and after the administration of gadolinium these lesions showed a marked reinforcement on the arterial phase, which persisted on the late venous phase. The differential diagnosis with pancreatic tumoral pathology was difficult. The pathological examination revealed a lymphoid angio follicular hyperplasia of hyaline vascular type. Conclusion: Retroperitoneal Castlelman's disease is a rare entity. The different imaging methods did not provide an accurate diagnosis of this entity since there are no pathognomonic features. The pathological examination was required to define the diagnosis in both reported cases. (author)

  18. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun

    2005-01-01

    There is little information on the ability of non-ECG-gated cardiac CT to demonstrate the coronary arteries of children. To evaluate the visibility of the origin and proximal course of coronary arteries on non-ECG-gated cardiac CT, in which the coronary artery was not of primary diagnostic concern, in children with congenital heart disease. From December 2002 to March 2004, 126 cardiac CT examinations from 104 children (median age 11 months; age range 1 day to 15 years) were evaluated. All patients had ventriculo-arterial concordance and no malformations of the great arteries; those with coronary artery anomalies were excluded. Contrast-enhanced 16-slice spiral CT was performed without ECG-gating and multiplanar images for coronary arteries were obtained. The visibility of coronary artery origins was graded on a three-point scale, while nine segments of the arteries were graded on a four-point scale. CT images in which it was possible to trace the coronary arteries were considered diagnostic. The visibility of each whole coronary artery and the origins and proximal four segments of coronary arteries were calculated. The visibility of coronary arteries was also correlated with patient age. The percentage of CT images of diagnostic quality was 49.3% for the whole coronary artery and 81.7% for the origins and proximal four segments. There was a significant positive correlation between the visibility of coronary arteries and age. Non-ECG-gated cardiac CT, in which the coronary artery is not of primary diagnostic concern, is frequently able to visualize the origin and proximal course of coronary arteries and may be helpful in detecting coronary artery anomalies in children with congenital heart disease. (orig.)

  19. PET/CT in sarcoidosis associated with oncological disease

    International Nuclear Information System (INIS)

    Bianco, C.; Servente, L.; Valuntas, L.; García Fontes, L.; Engler, H.

    2017-01-01

    Purposes: To describe the radiological findings of sarcoidosis or sarcoid-like reactions in cancer patients being monitored by positron emission computed tomography (PET/CT). Materials and methods: A retrospective analysis was performed on 18 PET/CT studies performed over 3 years in patients with lymphomas and solid tumours who presented with hypermetabolic hiliar-mediastinal adenopathies. The morphological pattern of these adenopathies, the distribution, and in some cases the association with pulmonary nodules, might suggest sarcoidosis as a differential diagnosis. Results: Oncological diseases corresponded to breast (4), prostate (3), ovary (2), and others (9). The adenopathies were classified in 7 of the 18 patients as benign after histological confirmation of sarcoidosis, anthracosis or sarcoid-like reaction. The evolutionary behaviour in 5 patients was compatible with benign lesions. The biopsy of 2 patients indicated secondary lesions and malignancy was confirmed by the evolution of the 4 remaining cases. There was a total of 12 (66%) benign lesions. Discussion: Sarcoidosis must be suspected in the presence of hypermetabolic hiliar-mediastinal adenopathies with a characteristic morphological pattern and pulmonary changes. However, biopsy is required to rule out oncological recurrence. The use of new PET/CT markers for differential diagnosis represents a challenge. Aminoacid synthesis tracers such as “1”8F-fluorothymidine (FLT) and “1”8F-fluoromethyltyrosine (FMT) are useful in the differentiation between malignancy and granulomatous diseases in oncologic patients. Conclusion: The differential diagnosis of sarcoidosis should be considered in the presence of bilateral symmetric mediastinal hilum lymphadenopathies. (authors) [es

  20. Utility of FDG PET/CT in IgG4-related systemic disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, K., E-mail: koyakn@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto (Japan); Nakamoto, Y.; Togashi, K. [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto (Japan)

    2012-04-15

    IgG4-related systemic disease (IgG4-RSD) is an emerging clinical entity about which much remains to be elucidated, in terms of its aetiology, pathogenesis, diagnosis, treatment and outcome. Autoimmune pancreatitis (AIP) and Mikulicz disease (MD) are the two major, well-studied constituents of IgG4-RSD. AIP and MD have common characteristics of forming tumour-mimicking lesions that consist of lymphoplasmacytic infiltrates and fibrosclerosis with numerous immunoglobulin G4 (IgG4)-positive plasma cells, as well as various multi-organ manifestations of IgG4-RSD. 2-[{sup 18}F]-fluoro-2-deoxy-D-glucose positron-emission tomography/ computed tomography (FDG PET/CT) enables the acquisition of whole-body images and provides functional information about disease activity; as such it has a valuable role in staging extent of disease, guiding biopsy, and monitoring response to treatment. However, FDG PET/CT is likely to be only one component of the management strategy, and clinical, laboratory, imaging and histological findings are crucial in the overall diagnosis of the condition. At present FDG PET/CT does not have a well-established role in the assessment of patients with IgG4-RSD and future prospective studies are required to define the cost-effectiveness and clinical impact in this patient group more accurately.

  1. Utility of FDG PET/CT in IgG4-related systemic disease

    International Nuclear Information System (INIS)

    Nakatani, K.; Nakamoto, Y.; Togashi, K.

    2012-01-01

    IgG4-related systemic disease (IgG4-RSD) is an emerging clinical entity about which much remains to be elucidated, in terms of its aetiology, pathogenesis, diagnosis, treatment and outcome. Autoimmune pancreatitis (AIP) and Mikulicz disease (MD) are the two major, well-studied constituents of IgG4-RSD. AIP and MD have common characteristics of forming tumour-mimicking lesions that consist of lymphoplasmacytic infiltrates and fibrosclerosis with numerous immunoglobulin G4 (IgG4)-positive plasma cells, as well as various multi-organ manifestations of IgG4-RSD. 2-[ 18 F]-fluoro-2-deoxy-D-glucose positron-emission tomography/ computed tomography (FDG PET/CT) enables the acquisition of whole-body images and provides functional information about disease activity; as such it has a valuable role in staging extent of disease, guiding biopsy, and monitoring response to treatment. However, FDG PET/CT is likely to be only one component of the management strategy, and clinical, laboratory, imaging and histological findings are crucial in the overall diagnosis of the condition. At present FDG PET/CT does not have a well-established role in the assessment of patients with IgG4-RSD and future prospective studies are required to define the cost-effectiveness and clinical impact in this patient group more accurately.

  2. Thoracic CT findings of adult-onset still's disease: a case report

    International Nuclear Information System (INIS)

    Choi, Sun Young; Kim, Ki Jun; Lee, Jung Whee; Lee, Sung Yong; Hong, Yeon Sik

    2006-01-01

    Adult-onset of Still's disease is a rare systemic rheumatic disorder. It involves various organs including the lungs and pleura. We report here the CT findings of a patient with the thoracic manifestations of Still's disease, including axillary and mediastinal lymphadenopathies, pleural and pericardial effusions and infiltrations in both lung bases

  3. Preoperative CT evaluation on nasal cavity for transsphenoidal approach

    International Nuclear Information System (INIS)

    Saeki, Naokatsu; Yamaura, Akira; Hoshi, Seiichiro; Sunada, Souichi; Sunami, Kenro

    1997-01-01

    Preoperative bone CT scans sliced parallel to the surgical plane were evaluated in 32 cases of transsphenoidal surgery. This method predicted patients with narrow nasal cavity, and helped to determine the rhinological maneuvers for providing a wider operative field. In addition, it helps to plan the need and extent of sella floor removal in re-operated cases. There was relatively little difference in the width and length of the nasal cavity between acromegalic and non-acromegalic patients. Hence, bone CT scans are useful in the preoperative evaluation of patients undergoing transsphenoidal surgery. (author)

  4. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  5. Major motor atrophic patterns in the face and neck: CT evaluation

    International Nuclear Information System (INIS)

    Harnsberger, H.R.; Dillon, W.P.

    1985-01-01

    Cranial nerve deficits from various pathologic processes of the head and neck may result in characteristic patterns of denervation muscular atrophy. Such atrophic patterns may be clues to the location and extent of the lesion, particularly when cranial nerves are involved early in the course of the disease process. Thirty-six patients with computed tomographic (CT) evidence of muscular atrophy secondary to pathologic conditions involving the motor division of cranial nerves were examined. Five characteristic denervation muscular atrophy patterns seen on CT scans were identified. Recognition of these atrophic patterns can prevent misinterpretation of their CT appearance and direct the CT examination to the course of the compromised cranial nerve from the brainstem to its peripheral innervation

  6. High resolution CT of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Harumi (Kyoto Univ. (Japan). Faculty of Medicine)

    1991-02-01

    The emergence of computed tomography (CT) in the early 1970s has greatly contributed to diagnostic radiology. The brain was the first organ examined with CT, followed by the abdomen. For the chest, CT has also come into use shortly after the introduction in the examination of the thoracic cavity and mediastinum. CT techniques were, however, of limited significance in the evaluation of pulmonary diseases, especially diffuse pulmonary diseases. High-resolution CT (HRCT) has been introduced in clinical investigations of the lung field. This article is designed to present chest radiographic and conventional tomographic interpretations and to introduce findings of HRCT corresponding to the same shadows, with a summation of the significance of HRCT and issues of diagnostic imaging. Materials outlined are tuberculosis, pneumoconiosis, bronchopneumonia, mycoplasma pneumonia, lymphangitic carcinomatosis, sarcoidosis, diffuse panbronchiolitis, interstitial pneumonia, and pulmonary emphysema. Finally, an overview of basic investigations evolved from HRCT is given. (N.K.) 140 refs.

  7. Evaluation of lateral margin of left lobe of the liver on CT scan : focus on perisplenic extension

    International Nuclear Information System (INIS)

    Seo, Chang Hye; Cha, Seong Sook; Lee, Byung Jin; Choi, Jae Young; Choi, Seok Jin; Eun, Choong Ki

    1996-01-01

    The perisplenic extension of the left lobe of the liver can be misinterpreted as a splenic or perisplenic lesion on ultrasonography(US) and computed tomography(CT). The purpose of our study is to classify the lateral margin of the left lobe of the liver into three types and to evaluate the incidence and the relationship between each type and abnormal liver on CT scan. A total of 515 abdominal CT scans from patients over 15 years old were retrospectively evaluated. Liver contours were divided into three types on the basis of degree of the left lateral extension of the left lobe of the liver. Type A was defined as the lateral extension of the left lobe of liver to the medial portion of the stomach, type C as the perisplenic portion, and type B as between the two types. Each type was further divided into normal and abnormal liver groups based on clinical, CT, surgical and patholigic findings and evaluated on its ratio of normal and abnormal liver, intrahepatic diseases associated with an abnormal liver and statistical significance between a normal and abnormal liver. The incidence of the three types of liver among the 515 patients was 360(69.9%), 121(23.5%) and 34(6.6%) patients in type A, B and C, respectively. Type C showed normal liver in six patients, which was 2.7% of all normal livers(221/515) and abnormal liver in 28 patients, which was 9.5% of all abnormal livers(294/515). Type A showed normal liver in 49.7%, abnormal liver in 50.3% and there was not statistically significant difference between normal and abnormal liver(p>0.05). Type B showed normal liver in 29.8% and abnormal liver in 70.2%;type C showed normal liver in 17.6%, abnormal liver in 82.4% and there was a statistically significant difference between normal and abnormal liver(P<0.001). The space occupying lesion(SOL) was most common(52.6%) in all the abnormal livers and hepatoma was the most common disease in the SOL(47.2%). In the abnormal type C liver, SOL(58%) and diffuse hepatopathy(32.8%) were

  8. Differential Diagnosis of the pancreatic disease : significance of perivascular changes at celiac trunk and superior mesenteric artery on CT

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ryang; Kim, Ki Whang; Yu, Jeong Sik; Kim, Ji Hyung; Kim, Dong Guk; Lee, Sung Il; Ahn, Chang Soo; Oh, Sei Jung [Yonsei Univ., Seoul (Korea, Republic of). Coll. of Medicine; Kim, Young Hwan [Sanggye Paik Hospital, Seoul (Korea, Republic of)

    1998-03-01

    The purpose of this paper is to classify perivascular change in the celiac trunk and SMA occurring in pancreatic disease and to evaluate its significance in differential diagnosis. In 73 patients with pancreatic disease (42, acute pancreatitis; 14, chronic pancreatitis; 17, pancreatic cancer) abdominal CT findings were retrospectively reviewed. We defined infiltration as linear or irregular density and thickening as presence of a soft tissue mantle surrounding the vessel, and statistically evaluated the usefulness of these factors for the differential diagnosis of pancreatic diseases. Thickening of the celiac trunk and SMA is a valuable finding in the differential diagnosis of pancreatic inflammatory disease and pancreatic cancer. When applied to the differential diagnosis of pancreatic disease, perivascular change should be classified as either infiltration or thickening. (author). 10 refs., 1 tab., 2 figs.

  9. Differential Diagnosis of the pancreatic disease : significance of perivascular changes at celiac trunk and superior mesenteric artery on CT

    International Nuclear Information System (INIS)

    Kwon, Ryang; Kim, Ki Whang; Yu, Jeong Sik; Kim, Ji Hyung; Kim, Dong Guk; Lee, Sung Il; Ahn, Chang Soo; Oh, Sei Jung

    1998-01-01

    The purpose of this paper is to classify perivascular change in the celiac trunk and SMA occurring in pancreatic disease and to evaluate its significance in differential diagnosis. In 73 patients with pancreatic disease (42, acute pancreatitis; 14, chronic pancreatitis; 17, pancreatic cancer) abdominal CT findings were retrospectively reviewed. We defined infiltration as linear or irregular density and thickening as presence of a soft tissue mantle surrounding the vessel, and statistically evaluated the usefulness of these factors for the differential diagnosis of pancreatic diseases. Thickening of the celiac trunk and SMA is a valuable finding in the differential diagnosis of pancreatic inflammatory disease and pancreatic cancer. When applied to the differential diagnosis of pancreatic disease, perivascular change should be classified as either infiltration or thickening. (author). 10 refs., 1 tab., 2 figs

  10. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    McEvoy, Fintan; Buelund, Lene Elisabeth; Strathe, Anders Bjerring

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  11. Solitary pulmonary nodules: impact of functional CT on the cost-effectiveness of FDG-PET

    International Nuclear Information System (INIS)

    Miles, K.A.; Keith, C.J.; Wong, D.C.; Griffiths, M.R.

    2002-01-01

    Full text: FDG-PET has been shown to be cost-effective for the evaluation of solitary pulmonary nodules (SPNs) in Australia. This study evaluates the impact on cost-effectiveness produced by incorporating a novel CT technique, functional CT, into diagnostic algorithms for characterisation of SPNs. Four diagnostic strategies were evaluated using decision tree sensitivity analysis. The first strategy comprised patients undergoing conventional CT alone (CT). The second comprised conventional CT followed by functional CT study (FCT), when the SPN was not benign on conventional CT. The third strategy comprised conventional CT, which if positive is followed by FDG-PET (PET) and a fourth strategy where patients with a positive conventional CT undergo functional CT, which if positive also undergo FDG-PET (FCT+PET). Values for disease prevalence and diagnostic accuracy of PET, CT and functional CT were obtained from a literature review, using Australia values where available. Procedure costs were derived from the Medicare Benefits Schedule and DRG Cost Weights for Australian public hospitals. The cost per patient, accuracy and Incremental Cost-Accuracy Ratio (ICAR) were determined for each strategy. Sensitivity analysis evaluated the effect of disease prevalence on cost-effectiveness. Results: At the prevalence of malignancy reported from Australian series (54%), the FCT strategy incurs the least cost ($5560/patient), followed by the FCT+PET ($5910/patient). The FCT+PET strategy is the most cost-effective strategy with an ICAR of $12059/patient, followed by the PET strategy with an ICAR of $12300/patient. At levels of disease prevalence below 54% the above relationship for cost-effectiveness remains the same. For high levels of disease prevalence, CT or FCT are found to be more cost-effective. At typical prevalence of malignancy the cost-effectiveness of PET is enhanced by the addition of functional CT, but at high prevalence functional CT alone is most cost

  12. A prospective study to evaluate the impact of FDG-PET on CT-based radiotherapy treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Leong, Trevor; Everitt, Craig; Yuen, Kally; Condron, Sara; Hui, Andrew; Ngan, Samuel Y.K.; Pitman, Alexander; Lau, Eddie W.F.; MacManus, Michael; Binns, David; Ackerly, Trevor; Hicks, Rodney J.

    2006-01-01

    Background and purpose: This prospective study sought to determine how the use of combined PET/CT for radiotherapy treatment planning of oesophageal cancer would alter the delineation of tumour volumes compared to CT alone if PET/CT is assumed to more accurately represent true disease extent. Patients and methods: All patients underwent FDG-PET/CT scanning in the radiotherapy treatment position. For each patient, two separate gross tumour volumes (GTV) were defined, one based on CT images alone (GTV-CT) and another based on combined PET/CT data (GTV-PET). Corresponding planning target volumes (PTV) were generated, and separate treatment plans were then produced. For each patient, volumetric analysis of GTV-CT, PTV-CT and GTV-PET was performed to quantify the proportion of PET-avid disease that was not included in the GTV and PTV (geographic miss) if CT data alone were used for radiotherapy planning. Assessment of the cranial and caudal extent of the primary oesophageal tumour as defined by CT alone vs PET/CT was also compared. Results: The addition of PET information altered the clinical stage in 8 of 21 eligible patients enrolled on the study (38%); 4 patients had distant metastatic disease and 4 had unsuspected regional nodal disease. Sixteen patients proceeded to the radiotherapy planning phase of the study and received definitive chemoradiation planned with the PET/CT data set. The GTV based on CT information alone excluded PET-avid disease in 11 patients (69%), and in five patients (31%) this would have resulted in a geographic miss of gross tumour. The discordance between CT and PET/CT was due mainly to differences in defining the longitudinal extent of disease in the oesophagus. The cranial extent of the primary tumour as defined by CT vs PET/CT differed in 75% of cases, while the caudal extent differed in 81%. Conclusions: This study demonstrates that if combined PET/CT is used for radiotherapy treatment planning, there may be alterations to the delineation

  13. Perpheral bronchopleural fistula: CT evaluation in 22 patients

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Min Young; Choi, Seong Hee; Kim, Eung Jo; Lee, Jin Joo; Kim, Oak

    1999-01-01

    To determine the usefulness of CT for the evaluation of peripheral bronchopleural fistulas. CT scans of 22 patients with persistent air leak, as seen on serial chest PA, and a clinical history, were retrospectively evaluated. We determined the visibility of direct communication between the lung and pleural space, and the frequency and location of this, and if direct communications were not visualized the probable cause. A bronchopleural fistula(n=13) or its probable cause(n=6) was visualized in 19 patients(86%). Direct communications between the lung and pleural space were seen in 13 patients(59%) ; there were six cases of tuberculous empyema, three of tuberculosis, two of necrotizing empyema, one of trauma, and one of postobstructive pneumonitis. In six patients, bronchiectatic change in peripheral lung adjacent to the pleural cavity was noted, and although this was seen as a probable cause of bronchopleural fistula, direct communication was invisible. Bronchopleural fistula or its probable cause was multiple in 18 of 19 patients, involving the upper and lower lobe in eight, the upper in nine, and the lower in two. CT is useful for evaluating the presence of bronchopleural fistula, and its frequency and location, and in patients in whom the fistula is not directly visualized, the cause of this

  14. Comparison of plain radiography and CT in postoperative evaluation of ankle fractures

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, K.; Qiang, M.; Li, H.; Dai, H.

    2015-01-01

    Aim: To compare postoperative plain radiographs with computed tomography (CT) post-processing images in evaluating the quality of anatomical reduction and internal fixation of ankle fractures. Materials and methods: A total of 168 patients who sustained closed ankle fracture and were treated with open reduction and internal fixation in East Hospital were reviewed. Postoperative plain radiographs and CT post-processing images were evaluated. The observation was performed under volume-rendering mode and multiplanar reconstruction mode. The assessment was performed by two independent orthopaedic surgeons. The inter- and intra-observer variations were analysed by kappa statistics. The differences between plain radiographs and CT post-processing images were compared using χ 2 test (McNemar's test). Results: Inter- and intra-observer agreement was almost perfect (0.813–1.000) using CT post-processing images, which was higher than that using plain radiographs (0.323–0.848). More non-anatomical reduction could be recognised in the supination–external rotation (SER), supination–adduction (SAD), pronation–external rotation (PER), and overall groups (p<0.05) and more poor internal fixation could be recognised in the SER, SAD, and overall groups (p<0.05) using CT post-processing images than using radiographs. Conclusion: More residual articular step, fracture fragment displacement, and poor internal fixation could be detected by CT post-processing images than plain radiographs. -- Highlights: •We compared postoperative X-rays with CT images in ankle fractures. •The evaluation agreement using CT images was higher than X-rays. •CT images detect more residual articular steps than X-rays. •CT images detect more fracture fragment displacement than X-rays. •CT images detect more poor internal fixation than X-rays

  15. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  16. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [JWG University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank [Hannover Medical School, Department of Neuroradiology, Hannover (Germany); Berding, Georg [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Weissenborn, Karin; Ahl, Bjoern [Hannover Medical School, Department of Neurology, Hannover (Germany)

    2006-10-15

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [{sup 15}O]H{sub 2}O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  17. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    International Nuclear Information System (INIS)

    Bisdas, Sotirios; Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank; Berding, Georg; Weissenborn, Karin; Ahl, Bjoern

    2006-01-01

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [ 15 O]H 2 O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  18. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  19. An evaluation of automatic coronary artery calcium scoring methods with cardiac CT using the orCaScore framework.

    Science.gov (United States)

    Wolterink, Jelmer M; Leiner, Tim; de Vos, Bob D; Coatrieux, Jean-Louis; Kelm, B Michael; Kondo, Satoshi; Salgado, Rodrigo A; Shahzad, Rahil; Shu, Huazhong; Snoeren, Miranda; Takx, Richard A P; van Vliet, Lucas J; van Walsum, Theo; Willems, Tineke P; Yang, Guanyu; Zheng, Yefeng; Viergever, Max A; Išgum, Ivana

    2016-05-01

    The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular disease (CVD) events. In clinical practice, CAC is manually identified and automatically quantified in cardiac CT using commercially available software. This is a tedious and time-consuming process in large-scale studies. Therefore, a number of automatic methods that require no interaction and semiautomatic methods that require very limited interaction for the identification of CAC in cardiac CT have been proposed. Thus far, a comparison of their performance has been lacking. The objective of this study was to perform an independent evaluation of (semi)automatic methods for CAC scoring in cardiac CT using a publicly available standardized framework. Cardiac CT exams of 72 patients distributed over four CVD risk categories were provided for (semi)automatic CAC scoring. Each exam consisted of a noncontrast-enhanced calcium scoring CT (CSCT) and a corresponding coronary CT angiography (CCTA) scan. The exams were acquired in four different hospitals using state-of-the-art equipment from four major CT scanner vendors. The data were divided into 32 training exams and 40 test exams. A reference standard for CAC in CSCT was defined by consensus of two experts following a clinical protocol. The framework organizers evaluated the performance of (semi)automatic methods on test CSCT scans, per lesion, artery, and patient. Five (semi)automatic methods were evaluated. Four methods used both CSCT and CCTA to identify CAC, and one method used only CSCT. The evaluated methods correctly detected between 52% and 94% of CAC lesions with positive predictive values between 65% and 96%. Lesions in distal coronary arteries were most commonly missed and aortic calcifications close to the coronary ostia were the most common false positive errors. The majority (between 88% and 98%) of correctly identified CAC lesions were assigned to the correct artery. Linearly weighted Cohen's kappa

  20. Standardization of MIP technique in three-dimensional CT portography: usefulness in evaluation of portosystemic collaterals in cirrhotic patients

    International Nuclear Information System (INIS)

    Kim, Jong Gi; Kim, Yong; Kim, Chang Won; Lee, Jun Woo; Lee, Suk Hong

    2003-01-01

    To assess the usefulness of three-dimensional CT portography using a standardized maximum intensity projection (MIP) technique for the evaluation of portosystemic collaterals in cirrhotic patients. In 25 cirrhotic patients with portosystemic collaterals, three-phase CT using a multide-tector-row helical CT scanner was performed to evaluate liver disease. Late arterial-phase images were transferred to an Advantage Windows 3.1 workstation (Gener Electric). Axial images were reconstructed by means of three-dimensional CT portography, using both a standardized and a non-standardized MIP technique, and the respective reconstruction times were determined. Three-dimensional CT portography with the standardized technique involved eight planes, namely the spleno-portal confluence axis (coronal, lordotic coronal, lordotic coronal RAO 30 .deg. C, and lordotic coronal LAO 30 .deg. C), the left renal vein axis (lordotic coronal), and axial MIP images (lower esophagus level, gastric fundus level and splenic hilum). The eight MIP images obtained in each case were interpreted by two radiologists, who reached a consensus in their evaluation. The portosystemic collaterals evaluated were as follows: left gastric vein dilatation; esophageal, paraesophageal, gastric, and splenic varix; paraumbilical vein dilatation; gastro-renal, spleno-renal, and gastro-spleno-renal shunt; mesenteric, retroperitoneal, and omental collaterals. The average reconstruction time using the non-standardized MIP technique was 11 minutes 23 seconds, and with the standardized technique, the time was 6 minutes 5 seconds. Three-dimensional CT portography with the standardized technique demonstrated left gastric vein dilatation (n=25), esophageal varix (n=18), paraesophageal varix (n=13), gastric varix (n=4), splenic varix (n=4), paraumbilical vein dilatation (n=4), gastro-renal shunt (n=3), spleno-renal shunt (n=3), and gastro-spleno-renal shunt (n=1). Using three-dimensional CT protography and the non

  1. FDG-PET/CT imaging in the management of HIV-associated multicentric Castleman's disease

    International Nuclear Information System (INIS)

    Barker, Rob; Kazmi, Fahrad; Stebbing, Justin; Chinn, Roger; Ngan, Sarah; Bower, Mark; Nelson, Mark; O'Doherty, Michael

    2009-01-01

    To evaluate the role of FDG-PET/CT scanning in the management of HIV-associated multicentric Castleman's disease (MCD) a rare lymphoproliferative disorder associated with infection by human herpesvirus 8 (HHV8). Nine patients with histologically confirmed MCD underwent fused FDG-PET/CT scans at initial MCD diagnosis (n = 3), at MCD relapse (n = 4), or during remission (n = 2). All seven patients with active MCD had markedly elevated plasma HHV8 viral loads, but the patients in remission had no HHV8 viraemia. The three patients with newly diagnosed MCD were not on antiretroviral therapy at the time of imaging, but the other six were all on fully suppressive antiretroviral regimens. In the seven patients with active MCD (newly diagnosed or relapse) 33/91 lymph node groups (36%) included radiologically enlarged nodes on the CT scan, whilst 57/91 lymph node groups (63%) showed enhanced FDG uptake on the PET scan. In scans from patients in remission, there were no enlarged lymph nodes on the CT scan but 3 lymph nodes (11%) demonstrated enhanced FDG uptake. The median SUV recorded for the seven patients with active MCD was 4.8 (range 2.6-9.3) which was significantly higher than the median value of 2.5 recorded for the patients in remission (Mann-Whitney U test, p = 0.011). Despite the small number of patients, in HIV-positive individuals with active MCD, FDG-PET scans more frequently detected abnormal uptake than CT scans detected enlarged lymph nodes. FDG-PET scanning has a useful role in the management of HIV-associated MCD in selecting appropriate sites for biopsy, and in staging and monitoring these lymphoproliferations. (orig.)

  2. Diagnostic CT imaging of the heart and aorta in health and disease

    International Nuclear Information System (INIS)

    Watanabe, Shigeru

    1981-01-01

    Despite recent remarkable developments in computed tomography (CT) for many organs in the human body, its clinical application concerning the cardiovascular system has been slow. In this study, we investigated clinical applications of CT for the cardiovascular system. We used conventional CT without ECG synchronization and ECG-synchronized CT. By the former, the size, the shape, and the arrangement of cardiovascular structures and the presence of pericardial effusion and calcifications were shown. For the latter, ECG gating method and data sorting method were used, and the cardiac border movement, the sequential changes of cross-sectional cardiac areas and the changing ratio were studied by both methods. The cardiac CT was found to be a useful noninvasive method for observation of anatomical features in various cardiovascular diseases and for the analysis of cardiac motion - especially, dyssynergia such as hypokinesis, akinesis and paradoxical movement in myocardial infarctions. (author)

  3. Disease progression in AIDS on PET fluorodeoxyglucose, CT and MR brain images

    International Nuclear Information System (INIS)

    Verma, R.C.; Bennett, L.; Gan, M.; Kloumehr, F.; Mathisen, G.; Jones, F.D.; Wasterlain, C.; Mandelkern, M.; Ropchan, J.; Blahd, W.; Yaghmal, I.

    1990-01-01

    This paper correlates changes in the brain demonstrated on F-18 fluorodeoxyglucose (FDG) positron emission tomographic (PET) scans and CT or MR images with disease severity in patients with acquired immunodeficiency syndrome (AIDS). Data from 30 patients who tested positive for human immunodeficiency virus (HIV) who were at various stages of AIDS, and who had undergone FDG PET, CT, and/or MR imaging were reviewed retrospectively. The average CD4 lymphocyte counts, an indicator of disease severity in AIDS, in 25 symptomatic (group I) and five healthy seropositive (group II) subjects were 300 and 694 cells/mm 3 , respectively. Cortical atrophy was present on CT and/or MR imaging in 92% in group I and only 20% in group II. Of the 17 patients in group I who underwent PET scans 11 demonstrated an elevated basal ganglia to frontal cortex (BG/FC) ratio of FDG uptake; only one of the four in group II had this finding

  4. Hydatid disease of the spleen; Ultrasonography, CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N. von; Stridbeck, H. (Dept. of Diagnostic Radiology, King Faisal Specialist Hospital, and Research Center, Riyadh (Saudi Arabia) Lund Univ. Hospital (Sweden))

    1992-09-01

    Seven patients with hydatid disease of the spleen were examined by radiography, ultrasound, CT, and in one case MR imaging. The observations were confirmed by patho-anatomic findings except in 2 patients where high indirect hemagglutination tests confirmed the diagnosis. (orig./MG).

  5. CT findings of cerebrovascular diseases in patients with atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Hideki; Iwamoto, Toshihiko; Kanaya, Kiyoshi; Hanyu, Haruo; Yamaguchi, Katsuhiko; Katsunuma, Hideyo

    1988-02-01

    CT findings of cerebrovascular diseases were studied in 111 patients with atrial fibrillation (Af). One of these patients had cerebral hemorrhage, and another, subarachnoid hemorrhage, while the others all had cerebral infarctions. CT revealed 122 lesions with a low-density area (LDA) in 105 patients. Based on the cerebral artery territory, the 122 CT lesions were classified into the following 8 types: 10 hemispheric, 43 superficial, 23 deep, 28 superficial+deep, 1 anterior cerebral artery, 6 posterior cerebral artery, 10 watershed, and 1 vertebrobasilar. Therefore, infarctions of the internal carotid artery (ICA) system, including 94 infarctions of the middle cerebral artery territory, were most frequent, accounting for 94% of all lesions. The ratio of the left to the right infarctions of the ICA system was 1.1:1. However, it should be noted that non-embolic infarctions can occur even patients with Af.

  6. Evaluation of abdominal CT in the initial treatment of abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishii, Takashi; Kuwata, Katsuya; Yoneyama, Chihiro; Kitamura, Kazuya; Sasaki, Yoshifumi; Kamachi, Masahiro; Nishiguchi, Hiroyasu.

    1986-01-01

    During the last four years 102 patients with abdominal trauma were examined by CT for preoperative evaluation in our hospital. In 35 patients (34 %), the CT scans revealed no abnormal findings. They were all managed conservatively except for one case of perforated small bowel. In 67 patients (66 %) CT revealed evidences of substantial abdominal or retroperitoneal trauma. In 30 of them CT findings were confirmed by surgery. Hepatic injury is usually easily recognized by CT. CT is also useful for the detection of renal or splenic injuries. The majority of those parenchymatous organ injuries were successfully managed with conservative therapy, despite apparent traumatic lesions revealed by CT. Repeat CT scans is proved to be very useful to follow the changes of these traumatic lesions. In conclusion, application of abdominal CT is extremely useful for the initial decision making in treatment of patients with abdominal trauma and for the follow-up observation of injured lesions. (author)

  7. Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol

    International Nuclear Information System (INIS)

    Thomas, C.; Patschan, O.; Nagele, U.; Stenzl, A.; Ketelsen, D.; Tsiflikas, I.; Reimann, A.; Brodoefel, H.; Claussen, C.; Kopp, A.; Heuschmid, M.; Schlemmer, H.P.; Buchgeister, M.

    2009-01-01

    The efficiency and radiation dose of a low-dose dual-energy (DE) CT protocol for the evaluation of urinary calculus disease were evaluated. A low-dose dual-source DE-CT renal calculi protocol (140 kV, 46 mAs; 80 kV, 210 mAs) was derived from the single-energy (SE) CT protocol used in our institution for the detection of renal calculi (120 kV, 75 mAs). An Alderson-Rando phantom was equipped with thermoluminescence dosimeters and examined by CT with both protocols. The effective doses were calculated. Fifty-one patients with suspected or known urinary calculus disease underwent DE-CT. DE analysis was performed if calculi were detected using a dedicated software tool. Results were compared to chemical analysis after invasive calculus extraction. An effective dose of 3.43 mSv (male) and 5.30 mSv (female) was measured in the phantom for the DE protocol (vs. 3.17/4.57 mSv for the SE protocol). Urinary calculi were found in 34 patients; in 28 patients, calculi were removed and analyzed (23 patients with calcified calculi, three with uric acid calculi, one with 2,8-dihyxdroxyadenine-calculi, one patient with a mixed struvite calculus). DE analysis was able to distinguish between calcified and non-calcified calculi in all cases. In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo. (orig.)

  8. Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol.

    Science.gov (United States)

    Thomas, C; Patschan, O; Ketelsen, D; Tsiflikas, I; Reimann, A; Brodoefel, H; Buchgeister, M; Nagele, U; Stenzl, A; Claussen, C; Kopp, A; Heuschmid, M; Schlemmer, H-P

    2009-06-01

    The efficiency and radiation dose of a low-dose dual-energy (DE) CT protocol for the evaluation of urinary calculus disease were evaluated. A low-dose dual-source DE-CT renal calculi protocol (140 kV, 46 mAs; 80 kV, 210 mAs) was derived from the single-energy (SE) CT protocol used in our institution for the detection of renal calculi (120 kV, 75 mAs). An Alderson-Rando phantom was equipped with thermoluminescence dosimeters and examined by CT with both protocols. The effective doses were calculated. Fifty-one patients with suspected or known urinary calculus disease underwent DE-CT. DE analysis was performed if calculi were detected using a dedicated software tool. Results were compared to chemical analysis after invasive calculus extraction. An effective dose of 3.43 mSv (male) and 5.30 mSv (female) was measured in the phantom for the DE protocol (vs. 3.17/4.57 mSv for the SE protocol). Urinary calculi were found in 34 patients; in 28 patients, calculi were removed and analyzed (23 patients with calcified calculi, three with uric acid calculi, one with 2,8-dihyxdroxyadenine-calculi, one patient with a mixed struvite calculus). DE analysis was able to distinguish between calcified and non-calcified calculi in all cases. In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo.

  9. Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C. [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Patschan, O.; Nagele, U.; Stenzl, A. [University of Tuebingen, Department of Urology, Tuebingen (Germany); Ketelsen, D.; Tsiflikas, I.; Reimann, A.; Brodoefel, H.; Claussen, C.; Kopp, A.; Heuschmid, M.; Schlemmer, H.P. [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Buchgeister, M. [University of Tuebingen, Medical Physics, Department of Radiation Oncology, Tuebingen (Germany)

    2009-06-15

    The efficiency and radiation dose of a low-dose dual-energy (DE) CT protocol for the evaluation of urinary calculus disease were evaluated. A low-dose dual-source DE-CT renal calculi protocol (140 kV, 46 mAs; 80 kV, 210 mAs) was derived from the single-energy (SE) CT protocol used in our institution for the detection of renal calculi (120 kV, 75 mAs). An Alderson-Rando phantom was equipped with thermoluminescence dosimeters and examined by CT with both protocols. The effective doses were calculated. Fifty-one patients with suspected or known urinary calculus disease underwent DE-CT. DE analysis was performed if calculi were detected using a dedicated software tool. Results were compared to chemical analysis after invasive calculus extraction. An effective dose of 3.43 mSv (male) and 5.30 mSv (female) was measured in the phantom for the DE protocol (vs. 3.17/4.57 mSv for the SE protocol). Urinary calculi were found in 34 patients; in 28 patients, calculi were removed and analyzed (23 patients with calcified calculi, three with uric acid calculi, one with 2,8-dihyxdroxyadenine-calculi, one patient with a mixed struvite calculus). DE analysis was able to distinguish between calcified and non-calcified calculi in all cases. In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo. (orig.)

  10. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  11. An experience of detection brain disease by roentgenographic CT on head

    International Nuclear Information System (INIS)

    Kobata, Daikichi

    1996-01-01

    MRI and MRA are recommended today from the standpoint of sensitivity for the detraction of asymptomatic brain disease, and roentgenographic CT on head is not recommended. Under certain circumstances, however, having recently been given an opportunity of detecting brain disease by means of roentgenographic CT on head, we make a report of the diagnostic results. The examinees were the staff members of a non-profit organization consisting of 62 men and 56 women whose age was 48.6 years on the average. Asymptomatic brain disease was found in 6 cases including 1 case of cerebral infarction, 1 case of calcification of cerebral vascular wall and 1 case of cranial osteoma with a suspicion of Gardner syndrome. Incidentally, there were 31 cases with a complaint of headache, 20 cases of hypertension and 3 cases with a past history of head trauma. After such findings were obtained, guidance was provided to each of them. (author)

  12. CT volumetric measurements of the orbits in Graves' disease

    International Nuclear Information System (INIS)

    Krahe, T.; Schlolaut, K.H.; Poss, T.; Trier, H.G.; Lackner, K.; Bonn Univ.; Bonn Univ.

    1989-01-01

    The volumes of the four recti muscles and the orbital fat was measured by CT in 40 normal persons and in 60 patients with clinically confirmed Graves' disease. Compared with normal persons, 42 patients (70%) showed an increase in muscle volume and 28 patients (46.7%) an increase in the amount of fat. In nine patients (15%) muscle volume was normal, but the fat was increased. By using volumetric measurements, the amount of fat in the orbits in patients with Graves' disease could be determined. (orig.) [de

  13. Cine CT in the evaluation of coronary bypass graft patency

    International Nuclear Information System (INIS)

    Stanford, W.; Rooholamini, M.; Rumberger, J.; Marcus, M.; Hiratzka, L.

    1986-01-01

    Cine CT produces axial images over an 8-cm section of the aorta in 50 msec. This characteristic makes the technique useful for evaluating coronary bypass graft (CBG) patency. With the use of 40 ml of 67% iothalamate sodium injected via an antecubital vein, 28 patients with 68 CBGs underwent cine CT. Ten patients with 21 CBGs also underwent cardiac catheterization. In the latter group the overall accuracy of cine CT compared to cardiac catheterization was 95.2% (20/21). The sensitivity was 94.1% (16/17), and the specificity was 100% (4/4). This figure compares favorably with the 92% sensitivity achieved with conventional CT

  14. Pelvic Hydatid Disease: CT and MRI Findings Causing Sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Sanal, Hatice Tuba; Kocaoglu, Murat; Bulakbasi, Nail; Yildirim, Duzgun [Gulhane Military Medical School, Department of Radiology, 06018, Ankara (Turkmenistan)

    2007-12-15

    Pelvic masses, especially hydatid disease, rarely present with sciatica. We present the computed tomography (CT) and the magnetic resonance imaging (MRI) findings of a 49-year-old female patient with presacral hydatid disease, who was evaluated for her sciatica. We also want to emphasize the importance of assessing the pelvis of patients with symptoms and clinical findings that are inconsistent and that cannot be satisfactorily explained by the spinal imaging findings. isc herniation in the lumbar spine is a well-known etiology of back pains and sciatica, but whenever disc herniation of the lumbar spine is excluded by the employed imaging modalities, then the pelvis should be examined for other possible etiologies of nerve compression. We describe here a patient, who was complaining of sciatica, with no abnormal findings in her lumbar spinal magnetic resonance imaging (MRI). The cause of her sciatica was found to be associated with a pelvic hydatid cyst compressing the lumbosacral nerve plexus. In conclusion, if no pathology is evident for the lumbar discal structures, in connection with the cause of sciatica and lumbar back pains, then the pelvis should also be examined for the possible etiologies of compression of the lumbosacral nerve plexus. Whenever a multiseptated cyst is come across in a patient of an endemic origin with a positive history for hydatid disease like surgery, indicating recurrence, hydatid cyst is the most likely diagnosis.

  15. Pelvic Hydatid Disease: CT and MRI Findings Causing Sciatica

    International Nuclear Information System (INIS)

    Sanal, Hatice Tuba; Kocaoglu, Murat; Bulakbasi, Nail; Yildirim, Duzgun

    2007-01-01

    Pelvic masses, especially hydatid disease, rarely present with sciatica. We present the computed tomography (CT) and the magnetic resonance imaging (MRI) findings of a 49-year-old female patient with presacral hydatid disease, who was evaluated for her sciatica. We also want to emphasize the importance of assessing the pelvis of patients with symptoms and clinical findings that are inconsistent and that cannot be satisfactorily explained by the spinal imaging findings. isc herniation in the lumbar spine is a well-known etiology of back pains and sciatica, but whenever disc herniation of the lumbar spine is excluded by the employed imaging modalities, then the pelvis should be examined for other possible etiologies of nerve compression. We describe here a patient, who was complaining of sciatica, with no abnormal findings in her lumbar spinal magnetic resonance imaging (MRI). The cause of her sciatica was found to be associated with a pelvic hydatid cyst compressing the lumbosacral nerve plexus. In conclusion, if no pathology is evident for the lumbar discal structures, in connection with the cause of sciatica and lumbar back pains, then the pelvis should also be examined for the possible etiologies of compression of the lumbosacral nerve plexus. Whenever a multiseptated cyst is come across in a patient of an endemic origin with a positive history for hydatid disease like surgery, indicating recurrence, hydatid cyst is the most likely diagnosis

  16. SPECT/CT: main applications in nuclear medicine

    International Nuclear Information System (INIS)

    Perera Pintado, Alejandro; Torres Aroche, Leonel A.; Vergara Gil, Alex; Batista Cuéllar, Juan F.; Prats Capote, Anaís

    2017-01-01

    SPECT/CT has represented not only the possibility of acquiring anatomical and functional images in one single study, but also a revolution for the clinical management of several diseases, taking the better of each one of these imaging modalities. The present work is aimed at presenting an overview of the most important applications of the SPECT/CT in the field of oncology, cardiology and neurology. New technological advances in the design of innovative solid state detectors and related equipment have had a positive effect on the performance of this kind of dual modality. This hybrid technique improves the sensitivity and the specificity of gammagraphic studies, as well as shortens the acquisition times and gives attenuation correction of co-registered images, which, in turn, makes their analysis easier. Some of the main applications for the study of oncological diseases are the following: localization and follow-up of different kinds of tumors, their metastasis and relapses, as well as the optimization of radiotherapy doses. This technique has been useful to evaluate the coronary artery disease allowing an adequate attenuation correction of images, the determination of calcium score, and performing angio-CT studies, according to the CT quality. SPECT/CT has also gained ground in the assessment of some neurological diseases. Conclusions: The introduction of new technological advances and radiopharmaceuticals thus predicting a more relevant place for SPECT/CT in clinical practice. (author)

  17. An evaluation of the use of oral contrast media in abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro [Mater Dei Hospital, Medical Imaging Department, Msida (Malta); Borg Grima, Karen; Zarb, Francis [Mater Dei Hospital, Faculty of Health Sciences, Msida (Malta)

    2014-11-15

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  18. An evaluation of the use of oral contrast media in abdominopelvic CT

    International Nuclear Information System (INIS)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro; Borg Grima, Karen; Zarb, Francis

    2014-01-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  19. How to use PET/CT in the evaluation of response to radiotherapy.

    Science.gov (United States)

    Decazes, Pierre; Thureau, Sébastien; Dubray, Bernard; Vera, Pierre

    2017-11-28

    Radiotherapy is a major treatment modality for many cancers. Tumor response after radiotherapy determines the subsequent steps of the patient's management (surveillance, adjuvant or salvage treatment and palliative care). Tumor response assessed during radiotherapy offers a promising opportunity to adapt the treatment plan to reduced / increased target volume, to specifically target sub-volumes with relevant biological characteristics (metabolism, hypoxia, proliferation ...) and to further spare the organs at risk. In addition to its role in the diagnosis and the initial staging, Positron Emission Tomography combined with a Computed Tomography (PET/CT) provides functional information and is therefore attractive to evaluate tumor response. To review the published data addressing PET/CT as an evaluation tool in irradiated tumors. Reports on PET/CT acquired at various times (during radiotherapy, after initial (chemo-)radiotherapy, after definitive radiotherapy and during posttreatment follow-up) in solid tumors (lung, head-and-neck, cervix, esophagus, prostate and rectum) were collected and reviewed. Various tracers and technical are also discussed. 18F-FDG PET/CT has a well-established role in clinical routine after definitive chemo-radiotherapy for locally advanced head-and-neck cancers. 18F-choline PET/CT is indicated in prostate cancer patients with biochemical failure. 18F-FDG PET/CT is optional in many others circumstances and the clinical benefits of assessing tumor response with PET/CT remain a field of very active research. The combination of PET with Magnetic Resonance Imaging (PET/MRI) may prove to be valuable in irradiated rectal and cervix cancers. Tumor response can be evaluated by PET/CT with clinical consequences in multiple situations, notably in head and neck and prostate cancers, after radiotherapy. Further clinical evaluation for most cancers is still needed, possibly in association to MRI.

  20. Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update

    Directory of Open Access Journals (Sweden)

    Nakanishi R

    2016-06-01

    Full Text Available Rine Nakanishi, Mathew J Budoff Los Angeles Biomedical Research Institute, Harbor-UCLA Medical Center, Torrance, CA, USA Abstract: After a decade of clinical use of coronary computed tomographic angiography (CCTA to evaluate the anatomic severity of coronary artery disease, new methods of deriving functional information from CCTA have been developed. These methods utilize the anatomic information provided by CCTA in conjunction with computational fluid dynamics to calculate fractional flow reserve (FFR values from CCTA image data sets. Computed tomography-derived FFR (CT-FFR enables the identification of lesion-specific drop noninvasively. A three-dimensional CT-FFR modeling technique, which provides FFR values throughout the coronary tree (HeartFlow FFRCT analysis, has been validated against measured FFR and is now approved by the US Food and Drug Administration for clinical use. This technique requires off-site supercomputer analysis. More recently, a one-dimensional computational analysis technique (Siemens cFFR, which can be performed on on-site workstations, has been developed and is currently under investigation. This article reviews CT-FFR technology and clinical evidence for its use in stable patients with suspected coronary artery disease. Keywords: fractional flow reserve, coronary computed tomographic angiography, FFRCT, cFFR

  1. RADIODIAGNOSIS OF PLEURAL LESIONS WITH USG AND CT SCAN

    Directory of Open Access Journals (Sweden)

    Bheemashanker

    2017-09-01

    Full Text Available BACKGROUND Ultrasound is easy available, less expensive study. It differentiates pleural effusion, consolidation and masses. CT scores in diagnosing early pleural lesions and helps in localising lesions differentiating benign and malignant. The aim of the study is to- 1. Assess the value of ultrasonography and computed tomography in evaluation of pleural lesions. 2. Determine the sensitivity and specificity of ultrasound and CT in pleural lesions. MATERIALS AND METHODS The present study was aimed at assessing the value of ultrasonography and CT in evaluating the pleural lesions. In our study, during the period of 12 months, 100 patients with pleural effusions were evaluated. The most common cause was transudate. Exudates consist of malignant and non-malignant causes. RESULTS The study group was defined into two groups- Malignant and non-malignant group based on pleural effusion of transudate and exudate types. CT and ultrasound has success rate of 100% and 85% respectively to identify neoplastic and non-neoplastic disease. Diagnostic accuracy of CT and ultrasound are comparable while CT scores over ultrasound in failed cases. CT has 100% sensitivity and 100% specificity in pleural lesions. CT has more therapeutic value compared to ultrasound. CONCLUSION The role of ultrasound and CT are complimentary, give high yield of positive results for pleural mass differentiation; useful for guided procedures like pleural biopsy and pleural drainage. Combined study not only useful for localisation of lesion, but also gives information about the extent of disease and characterising the tissue density by analysis of attenuation coefficient.

  2. Application of PET/CT in treatment response evaluation and recurrence prediction in patients with newly-diagnosed multiple myeloma.

    Science.gov (United States)

    Li, Ying; Liu, Junru; Huang, Beihui; Chen, Meilan; Diao, Xiangwen; Li, Juan

    2017-04-11

    Multiple myeloma (MM) causes osteolytic lesions which can be detected by 18F-fluorodeoxyglucose positron emission tomography/Computed tomography (18F-FDG PET/CT). We prospectively involve 96 Newly diagnosed MM to take PET/CT scan at scheduled treatment time (figure 1), and 18F-FDG uptake of lesion was measured by SUVmax and T/Mmax. All MM patients took bortezomib based chemotherapy as induction and received ASCT and maintenance. All clinical features were analyzed with the PET/CT image changes, and some relationships between treatment response and FDG uptakes changes were found: Osteolytic lesions of MM uptakes higher FDG than healthy volunteers, and this trend is more obvious in extramedullary lesions. Compared to X-ray, PET/CT was more sensitive both in discoering bone as well as extramedullary lesions. In newly diagnosed MM, several adverse clinical factors were related to high FDG uptakes of bone lesions. Bone lesion FDG uptakes of MM with P53 mutation or with hypodiploidy and complex karyotype were also higher than those without such changes. In treatment response, PET/CT showed higher sensitivity in detecting tumor residual disease than immunofixation electrophoresis. But in relapse prediction, it might show false positive disease recurrences and the imaging changes might be influenced by infections and hemoglobulin levels. PET/CT is sensitive in discovering meduallary and extrameduallary lesions of MM, and the 18F-FDG uptake of lesions are related with clinical indictors and biological features of plasma cells. In evaluating treatment response and survival, PET/CT showed its superiority. But in predicting relapse or refractory, it may show false positive results.

  3. Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)

    International Nuclear Information System (INIS)

    Hui, Peter K.T.; Goo, Hyun Woo; Du, Jing; Ip, Janice J.K.; Kanzaki, Suzu; Kim, Young Jin; Kritsaneepaiboon, Supika; Lilyasari, Oktavia; Siripornpitak, Suvipaporn

    2017-01-01

    With incremental utilization of pediatric cardiac CT in congenital heart disease, it is imperative to define its current radiation dose levels in clinical practice in order to help imagers optimize CT protocols, particularly in Asia and other developing countries where CT physicists are not readily available. To evaluate current radiation dose levels and influencing factors in cardiac CT in children with congenital heart disease in Asia by conducting a retrospective multi-center, multi-vendor study. We included 1,043 pediatric cardiac CT examinations performed in 8 centers between January 2014 and December 2014 to evaluate congenital heart disease. In five weight groups, we calculated radiation dose metrics including volume CT dose index, size-specific dose estimate, dose-length product and effective dose. Age at CT exam, gender, tube voltage, scan mode, CT indication and image reconstruction algorithm were analyzed to learn whether they influenced CT radiation dose. Volume CT dose index, size-specific dose estimate, dose-length product and effective dose of pediatric cardiac CT showed variations in the range of 4.3-23.8 mGy, 4.9-17.6 mGy, 55.8-501.3 mGy circle cm and 1.5-3.2 mSv, respectively, within five weight groups. Gender, tube voltage, scan mode and cardiac function assessment significantly influenced CT radiation dose. This multi-center, multi-vendor study demonstrated variations in radiation dose metrics of pediatric cardiac CT reflecting current practice in Asia. Gender, tube voltage, scan mode and cardiac function assessment should be considered as essential radiation dose-influencing factors in developing optimal pediatric cardiac CT protocols. (orig.)

  4. Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)

    Energy Technology Data Exchange (ETDEWEB)

    Hui, Peter K.T. [Hong Kong Baptist Hospital, Department of Radiology, Hong Kong, SAR (China); Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Du, Jing [Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Beijing (China); Ip, Janice J.K. [Queen Mary Hospital, Department of Radiology, Hong Kong, SAR (China); Kanzaki, Suzu [National Cerebral and Cardiovascular Center, Department of Radiology, Osaka (Japan); Kim, Young Jin [Yonsei University, Shinchon Severance Hospital, Department of Radiology, Seoul (Korea, Republic of); Kritsaneepaiboon, Supika [Songklanagarind Hospital, Prince of Songkla University, Department of Radiology, Hat Yai (Thailand); Lilyasari, Oktavia [University of Indonesia, National Cardiovascular Center Harapan Kita, Department of Cardiology, Jakarta (Indonesia); Siripornpitak, Suvipaporn [Ramathibodi Hospital, Mahidol University, Department of Radiology, Salaya (Thailand)

    2017-07-15

    With incremental utilization of pediatric cardiac CT in congenital heart disease, it is imperative to define its current radiation dose levels in clinical practice in order to help imagers optimize CT protocols, particularly in Asia and other developing countries where CT physicists are not readily available. To evaluate current radiation dose levels and influencing factors in cardiac CT in children with congenital heart disease in Asia by conducting a retrospective multi-center, multi-vendor study. We included 1,043 pediatric cardiac CT examinations performed in 8 centers between January 2014 and December 2014 to evaluate congenital heart disease. In five weight groups, we calculated radiation dose metrics including volume CT dose index, size-specific dose estimate, dose-length product and effective dose. Age at CT exam, gender, tube voltage, scan mode, CT indication and image reconstruction algorithm were analyzed to learn whether they influenced CT radiation dose. Volume CT dose index, size-specific dose estimate, dose-length product and effective dose of pediatric cardiac CT showed variations in the range of 4.3-23.8 mGy, 4.9-17.6 mGy, 55.8-501.3 mGy circle cm and 1.5-3.2 mSv, respectively, within five weight groups. Gender, tube voltage, scan mode and cardiac function assessment significantly influenced CT radiation dose. This multi-center, multi-vendor study demonstrated variations in radiation dose metrics of pediatric cardiac CT reflecting current practice in Asia. Gender, tube voltage, scan mode and cardiac function assessment should be considered as essential radiation dose-influencing factors in developing optimal pediatric cardiac CT protocols. (orig.)

  5. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    International Nuclear Information System (INIS)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo

    2013-01-01

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  6. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo [Children' s Hospital, Fudan University, Department of Radiology, Shanghai (China)

    2013-07-15

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  7. Metrizamide CT myelography of Hirayama's diseases

    International Nuclear Information System (INIS)

    Matsumura, Kiichiro; Inoue, Kiyoharu; Yagishita, Akira.

    1984-01-01

    We reported two cases of Hirayama's disease of about one year history. Case 1 had muscular weakness and atrophy of the upper extremity in the C7, C8, and Th1 segmental levels bilaterally but much more conspicuously on the left side. Case 2 had the same problem in the same segmental levels of the left upper extremity. In both cases the needle EMG showed neurogenic patterns in the atrophic muscles. Plain cervical X-rays and metrizamide myelographies were unremarkable in both cases. In case 1, metrizamide CT myelography showed a marked flattening and a loss of the normal rounded configuration of the antero-lateral aspects of the cervical spinal cord bilaterally but with a left sided emphasis. This was most prominent in the C6 vertebral body level, and was strictly localized to the C5, C6, and C7 vertebral body levels, which correspond to the C6, C7, C8, and Th1 spinal cord levels. There was however no physical compression of the spinal cord to explain the deformity. In case 2, metrizamide CT myelography showed a straightening and a loss of the normal rounded shape of the antero-lateral aspect of the cervical spinal cord on the left side, which was localized to the C6 and C7 vertebral body levels (corresponding to the C7, C8, and Th1 spinal cord levels). Taking the physical and EMG findings into account, we considered that the findings of the metrizamide CT myelography of the two cases represent the anterior horn atrophy localized to the lower cervical spinal cord. (author)

  8. Bone scan and SPECT/CT findings in marble bone disease

    International Nuclear Information System (INIS)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram

    2012-01-01

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ( 99m Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  9. Bone scan and SPECT/CT findings in marble bone disease

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram [Jaslok Hospital and Research Centre, Woril (India)

    2012-03-15

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ({sup 99m}Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  10. CT evaluation of the bile ducts in patients with fatty liver

    International Nuclear Information System (INIS)

    Quint, L.E.; Glazer, G.M.

    1984-01-01

    Computed tomographic (CT) evaluation of the bile ducts in the fatty liver can be difficult, since hepatic attenuation decreases with increased triglyceride content, and liver parenchyma may become isodense with bile. Forty-seven patients with fatty infiltration of the liver were retrospectively identified. In 7 of these patients, attenuation of liver and bile differed by less than 10 HU. In 2 patients, dilated intrahepatic ducts were invisible using CT, because bile was isodense with fatty liver parenchyma. Thus, the fatty liver presents a potential pitfall in CT evaluation of the bile ducts. For maximal accuracy scans should be obtained both before and after administration of intravenous urographic contrast material

  11. An evaluation on CT image acquisition method for medical VR applications

    Science.gov (United States)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  12. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

    Science.gov (United States)

    Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain

    2018-05-01

    To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) statistic (F)=28.52, padvanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.

  13. CT of chronic infiltrative lung disease: Prevalence of mediastinal lymphadenopathy

    Energy Technology Data Exchange (ETDEWEB)

    Niimi, Hiroshi; Kang, Eun-Young; Kwong, S. [Univ. of British Columbia and Vancouver Hospital and Health Sciences Centre (Canada)] [and others

    1996-03-01

    Our goal was to determine the prevalence of mediastinal lymph node enlargement at CT in patients with diffuse infiltrative lung disease. The study was retrospective and included 175 consecutive patients with diffuse infiltrative lung diseases. Diagnoses included idiopathic pulmonary fibrosis (IPF) (n = 61), usual interstitial pneumonia associated with collagen vascular disease (CVD) (n = 20), idiopathic bronchiolitis obliterans organizing pneumonia (BOOP) (n = 22), extrinsic allergic alveolitis (EAA) (n = 17), and sarcoidosis (n = 55). Fifty-eight age-matched patients with CT of the chest performed for unrelated conditions served as controls. The presence, number, and sites of enlarged nodes (short axis {ge}10 mm in diameter) were recorded. Enlarged mediastinal nodes were present in 118 of 175 patients (67%) with infiltrative lung disease and 3 of 58 controls (5%) (p < 0.001). The prevalence of enlarged nodes was 84% (46 of 55) in sarcoidosis, 67% (41 of 61) in IPF, 70% (14 of 20) in CVD, 53% (9 of 17) in EAA, and 36% (8 of 22) in BOOP. The mean number of enlarged nodes was higher in sarcoidosis (mean 3.2) than in the other infiltrative diseases (mean 1.2) (p < 0.001). Enlarged nodes were most commonly present in station 10R, followed by 7, 4R, and 5. Patients with infiltrative lung disease frequently have enlarged mediastinal lymph nodes. However, in diseases other than sarcoid, usually only one or two nodes are enlarged and their maximal short axis diameter is <15 mm. 11 refs., 2 figs., 1 tab.

  14. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  15. Orbital flourine-18-fluorodeoxyglucose positron emission tomography in patients with Graves' disease for evaluation of active inflammation.

    Science.gov (United States)

    Uslu-Beşli, Lebriz; Kabasakal, Levent; Sağer, Sait; Cicik, Erdoğan; Asa, Sertaç; Sönmezoğlu, Kerim

    2017-11-01

    Prediction and early diagnosis of orbitopathy is needed in patients with Graves' disease, especially when radioiodine therapy is planned. Positron emission tomography/computerized tomography (PET/CT) using flourine-18-fluorodeoxyglucose (FDG) is an effective imaging modality in detection of inflammation, however, its ability to detect orbital inflammation has not been well studied. The aim of our study is to determine the ability of FDG PET/CT to detect orbital inflammation related with Graves' disease, identify active orbitopathy, predict the radioiodine-triggered orbitopathy, and find out the effects of radioiodine on orbital inflammation. Total 31 Graves' disease patients and 17 controls were included. All Graves' disease patients underwent cranial FDG PET/CT imaging prior therapy. Radioiodine therapy and post-treatment PET/CT study was applied to 21 patients. PET/CT images of all examinees were evaluated, measuring extraocular muscle maximum standard uptake value (SUVmax) and muscle thickness. FDG uptake was increased in the majority of extraocular muscles in Graves' disease patients in comparison to controls and this increase was found to be irrelevant from muscle thickness. Extraocular muscle SUVmax values did not increase in Graves' orbitopathy patients who received radioiodine under corticosteroid prophylaxis. SUVmax level of all orbital rectus muscles were increased after radioiodine therapy in nonsmokers, whereas no increase was detected in smokers. FDG PET/CT may be helpful in detection of extraocular muscle inflammation and it may show ongoing orbitopathy in early stages of inflammation before anatomical changes occur.

  16. Performance evaluation of X-ray CT using visible scintillation light

    International Nuclear Information System (INIS)

    Kodama, Kiyoyuki; Hamada, Minoru; Suzuki, Tamotsu; Hashimoto, Masatoshi; Hanada, Takashi; Ide, Tatsuya; Maruyama, Koichi

    2004-01-01

    We proposed a new method of performance evaluation for X-ray CT using visible scintillation light and examined its usefulness in this study. When we scanned a plastic scintillator disk in a gantry opening of the X-ray CT, we could observe visible scintillation light. The rotation of the light-emitting area of the disk corresponded to that of the X-ray tube. We were able to record the scintillation light by digital video camera. By analyzing the area of visible scintillation light, the rotation speed of the X-ray tube, angular spread of the X-ray beam, uniformity of the incident X-rays, and change in X-ray energy were measured. No other method is available to obtain the above parameters of X-ray CT during a single CT scan. In the measurements of the uniformity of incident X-rays and change of X-ray energy, our method showed good accuracy in detecting the attenuation caused by the couch between the X-ray tube and the plastic scintillator disc. The proposed method is inexpensive and easy-to-use. We conclude that the method is a useful tool for performance evaluation as well as a maintenance tool for X-ray CT. (author)

  17. CT findings of cerebrovascular diseases in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Kubo, Hideki; Iwamoto, Toshihiko; Kanaya, Kiyoshi; Hanyu, Haruo; Yamaguchi, Katsuhiko; Katsunuma, Hideyo

    1988-01-01

    CT findings of cerebrovascular diseases were studied in 111 patients with atrial fibrillation (Af). One of these patients had cerebral hemorrhage, and another, subarachnoid hemorrhage, while the others all had cerebral infarctions. CT revealed 122 lesions with a low-density area (LDA) in 105 patients. Based on the cerebral artery territory, the 122 CT lesions were classified into the following 8 types: 10 hemispheric, 43 superficial, 23 deep, 28 superficial+deep, 1 anterior cerebral artery, 6 posterior cerebral artery, 10 watershed, and 1 vertebrobasilar. Therefore, infarctions of the internal carotid artery (ICA) system, including 94 infarctions of the middle cerebral artery territory, were most frequent, accounting for 94% of all lesions. The ratio of the left to the right infarctions of the ICA system was 1.1:1. However, it should be noted that non-embolic infarctions can occur even patients with Af. (author)

  18. The CT evaluation of cephalic and cervical adenoid cystic carcinoma

    International Nuclear Information System (INIS)

    Gu Yajia; Wang Jiuhua; Wang HOngshi; Chen Tongzhen

    2000-01-01

    Objective: To evaluate the CT manifestations of cephalic and cervical adenoid cystic carcinoma (ACC). Methods: Thirty-three cases of ACC were analyzed retrospectively. Of all cases, 22 cases underwent operation and 11 cases received radiotherapy. The manifestations of CT were evaluated and compared with the clinical and pathologic results. Results: Tumors originated from parotid gland (5 cases), floor of mouth (5 cases), nasal cavity and nasopharynx (5 cases), tongue (4 cases), palate (3 cases), tracheas (3 cases), submandibular gland (2 cases), tonsilla (2 cases), maxillary sinus (2 cases), and cheek (2 cases), respectively. The CT manifestations included: (1)ethmoid density in 21 cases, partial ethmoid density in 5 cases. (2)the morphology of ACC was irregular and the growth of the tumor was amorphous in 17 cases, and the margin of the tumor was vague in 20 cases. (3)ACC often grew along the nerve with infiltration, which caused destruction of the skull base in 5 cases and atrophy of mastication muscles and/or buccinator in 3 cases. Conclusion: (1)The characteristics of cephalic and cervical adenoid cystic carcinoma on CT scans were ethmoid density, infiltrated growth, growing along the nerve with infiltration, and submucous growth. Among them, the most important manifestation, which could lead to the histologic diagnosis on CT, was ethmoid density. (2)The range of ACC was usually underestimated on CT. (3)The manifestation of tumor growth along the nerve could be apparently displayed on MRI

  19. Characteristic of muscle involvement evaluated by CT scans in early stages of progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Arai, Yumi

    1993-01-01

    Muscle CT scans were performed in order to compare the characteristic distribution of progressive muscle involvement in the early stages of Duchenne type (DMD) and Fukuyama type muscular dystrophy (FCMD). Muscle images at the levels of the 3rd lumbar vertebra, thigh and calf were assessed by visual inspection, and mean CT numbers calculated for individual muscles were statistically analysed. On visual inspection, intramuscular low density areas and muscular atrophy were observed in the muscles of older patients with either disease. These changes were, however, more extensive at thigh level in DMD, and at calf level in FCMD. Nevertheless, the mean CT numbers of muscles in which only slight changes were grossly visible on CT scans displayed progressive decreases with increasing age. Moreover, a significant negative relationship was recognizable between age and mean CT number in almost all muscles examined. Comparison of the slopes of the regression lines revealed that the so-called selective pattern of muscle involvement characteristic of the symptomatic stage had already partially manifested in the preclinical or early stages of both diseases. In FCMD, the rates of decrease in CT numbers were extremely rapid for calf muscles as compared with those in DMD, indicating that this is one reason for FCMD patients never becoming ambulatory. However, for almost all of the other muscles, the CT numbers in FCMD decreased in parallel with the corresponding CT numbers in DMD; thus, these diseases displayed a similarity in the pattern of muscle involvement, despite their different pathogenetic mechanisms and inheritance patterns. (author)

  20. Evaluation of visual and computer-based CT analysis for the identification of functional patterns of obstruction and restriction in hypersensitivity pneumonitis.

    Science.gov (United States)

    Jacob, Joseph; Bartholmai, Brian J; Brun, Anne Laure; Egashira, Ryoko; Rajagopalan, Srinivasan; Karwoski, Ronald; Kouranos, Vasileios; Kokosi, Maria; Hansell, David M; Wells, Athol U

    2017-11-01

    To determine whether computer-based quantification (CALIPER software) is superior to visual computed tomography (CT) scoring in the identification of CT patterns indicative of restrictive and obstructive functional indices in hypersensitivity pneumonitis (HP). A total of 135 consecutive HP patients had CT parenchymal patterns evaluated quantitatively by both visual scoring and CALIPER. Results were evaluated against: forced vital capacity (FVC), total lung capacity (TLC), diffusing capacity for carbon monoxide (DL CO ) and a composite physiological index (CPI) to identify which CT scoring method better correlated with functional indices. CALIPER-derived scores of total interstitial lung disease extent correlated more strongly than visual scores: FVC (CALIPER R = 0.73, visual R = 0.51); DL CO (CALIPER R = 0.61, visual R = 0.48); and CPI (CALIPER R = 0·70, visual R = 0·55). The CT variable that correlated most strongly with restrictive functional indices was CALIPER pulmonary vessel volume (PVV): FVC R = 0.75, DL CO R = 0.68 and CPI R = 0.76. Ground-glass opacity quantified by CALIPER alone demonstrated strong associations with restrictive functional indices: CALIPER FVC R = 0.65; DL CO R = 0.59; CPI R = 0.64; and visual = not significant. Decreased attenuation lung quantified by CALIPER was a better morphological measure of obstructive lung disease than equivalent visual scores as judged by relationships with TLC (CALIPER R = 0.63 and visual R = 0.12). All results were maintained on multivariate analysis. CALIPER improved on visual scoring in HP as judged by restrictive and obstructive functional correlations. Decreased attenuation regions of the lung quantified by CALIPER demonstrated better linkages to obstructive lung physiology than visually quantified CT scores. A novel CALIPER variable, the PVV, demonstrated the strongest linkages with restrictive functional indices and could represent a new

  1. Convolutional neural networks for the detection of diseased hearts using CT images and left atrium patches

    Science.gov (United States)

    Dormer, James D.; Halicek, Martin; Ma, Ling; Reilly, Carolyn M.; Schreibmann, Eduard; Fei, Baowei

    2018-02-01

    Cardiovascular disease is a leading cause of death in the United States. The identification of cardiac diseases on conventional three-dimensional (3D) CT can have many clinical applications. An automated method that can distinguish between healthy and diseased hearts could improve diagnostic speed and accuracy when the only modality available is conventional 3D CT. In this work, we proposed and implemented convolutional neural networks (CNNs) to identify diseased hears on CT images. Six patients with healthy hearts and six with previous cardiovascular disease events received chest CT. After the left atrium for each heart was segmented, 2D and 3D patches were created. A subset of the patches were then used to train separate convolutional neural networks using leave-one-out cross-validation of patient pairs. The results of the two neural networks were compared, with 3D patches producing the higher testing accuracy. The full list of 3D patches from the left atrium was then classified using the optimal 3D CNN model, and the receiver operating curves (ROCs) were produced. The final average area under the curve (AUC) from the ROC curves was 0.840 +/- 0.065 and the average accuracy was 78.9% +/- 5.9%. This demonstrates that the CNN-based method is capable of distinguishing healthy hearts from those with previous cardiovascular disease.

  2. Evaluation of patient absorbed dose in a PET-CT test

    International Nuclear Information System (INIS)

    Guerra P, F.; Mourao F, A. P.; Santana, P. C.

    2017-10-01

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg 18 F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the 18 F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  3. Evaluation of patient absorbed dose in a PET-CT test

    Energy Technology Data Exchange (ETDEWEB)

    Guerra P, F.; Mourao F, A. P. [Federal University of Minas Gerais, Department of Nuclear Engineering, Av. Antonio Carlos 6627, CEP 31270-901, Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P. C., E-mail: fgpaiva92@gmail.com [Federal University of Minas Gerais, Medical School, Av. Prof. Alfredo Balena 190, CEP 30123970, Santa Efigenia, Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg {sup 18}F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the {sup 18}F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  4. The value of brain scanning in cerebro-vascular disease by CT

    International Nuclear Information System (INIS)

    Huber, G.; Emde, H.

    1980-01-01

    Brain scanning by scintigraphy and CT studies of the brain are complementary methods. The precise demonstration of the anatomy and the pathology of the brain by CT is supplemented by brain scintigraphy due to the latter's value to assess the hemodynamic properties of a lesion and thus provide important clues to its site and sometimes even its histology. This is especially true in vascular brain disease thus either dispensing the need for an invasive procedure such as angiography or providing information for a specific approach. (orig.) 891 MG/orig. 892 MKO [de

  5. Sensitivity of whole-body CT and MRI versus projection radiography in the detection of osteolyses in patients with monoclonal plasma cell disease

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Maya B., E-mail: m.mueller-wolf@dkfz.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Department of Radiology, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Murray, Fritz, E-mail: fritz.murray@hotmail.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Kilk, Kerstin, E-mail: k_fechtner@hotmail.com [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); Hillengass, Jens, E-mail: jens.hillengass@med.uni-heidelberg.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Delorme, Stefan, E-mail: s.delorme@dkfz-heidelberg.de [Department of Radiology, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Heiss, Christiane, E-mail: c.heiss@dkfz-heidelberg.de [Department of Biostatistics, German Cancer Research Center (Dkfz), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Neben, Kai, E-mail: k.neben@klinikum-mittelbaden.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Goldschmidt, Hartmut, E-mail: hartmut.goldschmidt@med.uni-heidelberg.de [Department of Haematology, Oncology, Rheumatology, University Hospital Heidelberg and National Center for Tumour Diseases, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich, E-mail: hu.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg Germany (Germany); and others

    2014-07-15

    Purpose: To compare sensitivity of whole-body Computed Tomography (wb-CT) and whole-body Magnetic Resonance Imaging (wb-MRI) with Projection Radiography (PR) regarding each method's ability to detect osteolyses in patients with monoclonal plasma cell disease. Patients and methods: The bone status of 171 patients was evaluated. All patients presented with multiple myeloma (MM) of all stages, monoclonal gammopathy of unknown significance (MGUS) or solitary plasmacytoma. Two groups were formed. Group A consisted of 52 patients (26 females, 26 males) with an average age of 62 years (range, 45–89 years) who received, both, PR and wb-CT as part of their diagnostic work-up. Group B comprised 119 patients (58 females, 61 males) averaging 57 years of age (range, 20–80 years) who received, both, PR and wb-MRI. Two experienced radiologists were blinded regarding the disease status and assessed the number and location of osteolyses in consensus. A distinction was made between axial and extra-axial lesions. Results: In group A, wb-CT revealed osteolyses in 12 patients (23%) that were not detected in PR. CT was superior in detecting lesions in patients with osteopenia and osteoporosis. Compared with PR, wb-CT was significantly more sensitive in detecting osteolyses than PR (p < 0.001). This was particularly true for axial lesions. Additionally, CT revealed clinically relevant incidental findings in 33 patients (63%). In group B, wb-MRI revealed lesions in 19 patients (16%) that were not detected in PR. All lesions detected by PR were also detected by wb-MRI and wb-CT. Wb-MRI and wb-CT are each superior to PR in detecting axial lesions. Conclusion: Wb-CT can detect 23% more focal lesions than PR, especially in the axial skeleton. Therefore, this imaging method should be preferred over PR in the diagnostic work-up and staging of patients with monoclonal plasma cell disease.

  6. CT findings of pulmonary tuberculosis in adult patients with no underlying disease

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Takeuchi, Noriyuki; Johkoh, Tsuyoshi

    1992-01-01

    To evaluate the CT spectrum of pulmonary tuberculosis, we reviewed CT of the chest in 80 adult patients with active pulmonary tuberculosis who had not been treated for tuberculosis. Main patterns seen in patients with active tuberculosis were: (1) nodular shadow (56%), (2) confluent consolidation (15%), and (3) round consolidation (16%). Other CT patterns were: (1) miliary tuberculosis (n=4), (2) pleural effusion only (n=4), and (3) normal chest (n=2). Major features seen at CT included segmental distribution (97%), satellite lesions (86%), single cavity in each cavitary lesion (95%), ectatic change of the bronchi, tendency of distortion or contraction. (author)

  7. Acute gynecologic disorders in adolescents: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Tong [Soonchunhyang Univ. Cheonan Hospital/Soonchunhyang Univ. College of Medicine, Cheonan (Korea, Republic of)

    2012-09-15

    Gynecologic disorders that cause pelvic pain in adolescents include hemorrhagic ovarian cysts, rupture or torsion of ovarian cyst or tumors, hematocolpos caused by vaginal obstruction, endometriosis, cystic uterine adenomyosis, pelvic inflammatory diseases, and pelvic inclusion cyst. The use of CT for the evaluation of pelvic pain is increasing, and CT is useful if ultrasound findings are not decisive and the lesion is extensive.

  8. Amyloid goiter in a child - US, CT and MR evaluation

    International Nuclear Information System (INIS)

    Perez Fontan, F.J.; Mosquera Oses, J.; Pombo Felipe, F.; Rodriguez Sanchez, I.; Arnaiz Pena, S.

    1992-01-01

    There are few radiological descriptions of amyloid goiter, basically in adult patients or oriental origin. We present a ten-year-old boy with Still's disease and secondary thyroid amyloidosis, describing the US, CT and MR findings. (orig.)

  9. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  10. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  11. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  12. PET/CT in therapy evaluation of patients with lung cancer

    DEFF Research Database (Denmark)

    Langer, Natasha Hemicke; Christensen, Tine Nøhr; Langer, Seppo W

    2014-01-01

    FDG-PET/CT is a well documented and widespread used imaging modality for the diagnosis and staging of patient with lung cancer. FDG-PET/CT is increasingly used for the assessment of treatment effects during and after chemotherapy. However, PET is not an accepted surrogate end-point for assessment...... of response rate in clinical trials. The aim of this review is to present current evidence on the use of PET in response evaluation of patients with lung cancer and to introduce the pearls and pitfalls of the PET-technology relating to response assessment. Based on this and relating to validation criteria......, including stable technology, standardization, reproducibility and broad availability, the review discusses why, despite numerous studies on response assessment indicating a possible role for FDG-PET/CT, PET still has no place in guidelines relating to response evaluation in lung cancer....

  13. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    International Nuclear Information System (INIS)

    Farago, Giuseppe; Caldiera, V.; Antozzi, C.; Bellino, A.; Innocenti, A.; Ciceri, E.

    2017-01-01

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  14. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    Energy Technology Data Exchange (ETDEWEB)

    Farago, Giuseppe [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Fondazione IRCCS Istituto Neurologico Carlo Besta, Department of Interventional Neuroradiology, Milan (Italy); Caldiera, V. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Antozzi, C.; Bellino, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuroimmunology and Neuromuscular Diseases, Milan (Italy); Innocenti, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuro-Oncology, Milan (Italy); Ciceri, E. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Azienda Ospedaliera Universitaria Integrata Borgo Trento, Department of Neuroradiology, Verona (Italy)

    2017-05-15

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  15. SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

    International Nuclear Information System (INIS)

    Zhang, J; Ge, G; Winkler, M; Cong, W; Wang, G

    2014-01-01

    Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose

  16. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  17. Association of esophageal inflammation, obesity and gastroesophageal reflux disease: from FDG PET/CT perspective.

    Directory of Open Access Journals (Sweden)

    Yen-Wen Wu

    Full Text Available OBJECTIVE: Gastroesophageal reflux disease (GERD is associated with bothersome symptoms and neoplastic progression into Barrett's esophagus and esophageal adenocarcinoma. We aim to determine the correlation between GERD, esophageal inflammation and obesity with 18F-Fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT. METHODS: We studied 458 subjects who underwent a comprehensive health check-up, which included an upper gastrointestinal endoscopy, FDG PET/CT and complete anthropometric measures. GERD symptoms were evaluated with Reflux Disease Questionnaire. Endoscopically erosive esophagitis was scored using the Los Angeles classification system. Inflammatory activity, represented by standardized uptake values (SUVmax of FDG at pre-determined locations of esophagus, stomach and duodenum, were compared. Association between erosive esophagitis, FDG activity and anthropometric evaluation, including body mass index (BMI, waist circumference, visceral and subcutaneous adipose tissue volumes were analyzed. RESULTS: Subjects with erosive esophagitis (n = 178, 38.9% had significantly higher SUVmax at middle esophagus (2.69±0.74 vs. 2.41±0.57, P<.001 and esophagogastric junction (3.10±0.89 vs. 2.38±0.57, P<.001, marginally higher at upper esophageal sphincter (2.29±0.42 vs. 2.21±0.48, P = .062, but not in stomach or duodenum. The severity of erosive esophagitis correlated with SUVmax and subjects with Barrett's esophagus had the highest SUVmax at middle esophagus and esophagogastric junction. Heartburn positively correlated with higher SUVmax at middle oesophagus (r = .262, P = .003. Using multivariate regression analyses, age (P = .027, total cholesterol level (P = .003, alcohol drinking (P = .03, subcutaneous adipose tissue (P<.001, BMI (P<.001 and waist circumference (P<.001 were independently associated with higher SUVmax at respective esophageal locations. CONCLUSIONS: Esophageal

  18. A prospective trial comparing FDG-PET/CT and CT to assess tumor response to cetuximab in patients with incurable squamous cell carcinoma of the head and neck

    International Nuclear Information System (INIS)

    Adkins, Douglas; Ley, Jessica; Dehdashti, Farrokh; Siegel, Marilyn J; Wildes, Tanya M; Michel, Loren; Trinkaus, Kathryn; Siegel, Barry A

    2014-01-01

    Computed tomography (CT), the standard method to assess tumor response to cetuximab in incurable squamous cell carcinoma of the head and neck (SCCHN), performs poorly as judged by the disparity between high disease control rate (46%) and short time to progression (TTP) (70 days). F-18 fluorodeoxyglucose positron emission tomography (FDG-PET)/CT is an alternative method to assess tumor response. The primary objective of this prospective trial was to evaluate the metabolic response of target lesions, assessed as the change in maximum standardized uptake value (SUV max ) on FDG-PET/CT before and after 8 weeks (cycle 1) of cetuximab. Secondary objectives were to compare tumor response by CT (RECIST 1.0) and FDG-PET/CT (EORTC criteria) following cycle 1, and determine TTP with continued cetuximab administration in patients with disease control by CT after cycle 1 but stratified for disease control or progression by FDG-PET/CT. Among 27 patients, the mean percent change of SUV max of target lesions after cycle 1 was −21% (range: +72% to −81%); by FDG-PET/CT, partial response (PR)/stable disease (SD) occurred in 15 patients (56%) and progression in 12 (44%), whereas by CT, PR/SD occurred in 20 (74%) and progression in 7 (26%). FDG-PET/CT and CT assessments were discordant in 14 patients (P = 0.0029) and had low agreement (κ = 0.30; 95% confidence interval [CI]: 0.12, 0.48). With disease control by CT after cycle 1, median TTP was 166 days (CI: 86, 217) if the FDG-PET/CT showed disease control and 105 days (CI: 66, 159) if the FDG-PET/CT showed progression (P < 0.0001). Median TTP of the seven patients whose post cycle 1 CT showed progression compared to the 12 whose FDG-PET/CT showed progression were similar (53 [CI: 49, 56] vs. 61 [CI: 50, 105] days, respectively). FDG-PET/CT may be better than CT in assessing benefit of cetuximab in incurable SCCHN

  19. Role of CT in management of mesothelioma

    International Nuclear Information System (INIS)

    Godwin, J.D.; Rusch, V.W.; Shuman, W.P.

    1987-01-01

    The authors examined the accuracy of CT in determining the extent of disease and its role in the follow-up of patients with malignant pleural mesothelioma. Twenty patients underwent complex CT-anatomic correlation. CT was unable to demonstrate small tumor implants in the chest wall (four cases), upper abdomen (two cases), or contralateral hemidiaphragm (one case). Occasionally there was difficulty distinguishing tumor invasion of soft tissues from simple contiguity, benign from malignant nodes, and recurrent tumor from surgical changes. In six of eight treated patients, CT demonstrated recurrence -8 months before signs or symptoms appeared. Despite its limitations, CT is essential in the initial evaluation and follow-up of patients with mesothelioma

  20. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  1. Evaluation of obstructive airway lesions in complex congenital heart disease using composite volume-rendered images from multislice CT

    International Nuclear Information System (INIS)

    Choo, Ki Seok; Kim, Chang Won; Lee, Tae Hong; Kim, Suk; Kim, Kun Il; Lee, Hyoung Doo; Ban, Ji Eun; Sung, Si Chan; Chang, Yun Hee

    2006-01-01

    Multislice CT (MSCT) allows high-quality volume-rendered (VR) and composite volume-rendered images. To investigate the clinical usefulness of composite VR images in the evaluation of the relationship between cardiovascular structures and the airway in children with complex congenital heart disease (CHD). Four- or 16-slice MSCT scanning was performed consecutively in 77 children (mean age 6.4 months) with CHD and respiratory symptoms, a chest radiographic abnormality, or abnormal course of the pulmonary artery on ECHO. MSCT scanning was performed during breathing or after sedation. Contrast medium (2 ml/kg) was administered through a pedal venous route or arm vein in all patients. The VR technique was used to reconstruct the cardiovascular structures and airway, and then both VR images were composed using the commercial software (VoxelPlus 2 ; Daejeon, Korea). Stenoses were seen in the trachea in 1 patient and in the bronchi in 14 patients (19%). Other patients with complex CHD did not have significant airway stenoses. Composite VR images with MSCT can provide more exact airway images in relationship to the surrounding cardiovascular structures and thus help in optimizing management strategies in treating CHD. (orig.)

  2. CT evaluation of underlying cause in spontaneous subcapsular and perirenal hemorrhage

    International Nuclear Information System (INIS)

    Sebastia, M.C.; Perez-Molina, M.O.; Alvarez-Castells, A.; Quiroga, S.; Pallisa, E.

    1997-01-01

    We evaluated the CT scans of 13 patients with spontaneous subcapsular or perinephric hemorrhage (SPH) associated with these underlying causes: 4 angiomyolipomas, 2 renal cell carcinomas, 1 renal metastatic malignant melanoma, 1 ruptured renal artery aneurysm, 1 adrenal myelolipoma, 1 ruptured renal abscess, 2 ruptured hemorrhagic cysts, and 1 patient with undiagnosed coagulation disorder. Our objective was to ascertain whether an underlying cause of SPH was identifiable by CT, and to determine the extension of the hematomas. Computed tomography identified the hematoma in all 13 cases (sensitivity 100 %). In all 12 cases in which there was a renal or adrenal anatomic lesion, the underlying cause was identified with CT (100 %), with correct diagnosis in 11 cases (91.6 %). The case in which no lesion was identified was the undiagnosed coagulation disorder. We conclude that CT is a useful technique for the initial evaluation of SPH, permitting diagnosis of hemorrhage and identification of the underlying cause. (orig.). With 6 figs., 1 tab

  3. CT evaluation of underlying cause in spontaneous subcapsular and perirenal hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Sebastia, M.C. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Perez-Molina, M.O. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Alvarez-Castells, A. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Quiroga, S. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Pallisa, E. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain)

    1997-06-01

    We evaluated the CT scans of 13 patients with spontaneous subcapsular or perinephric hemorrhage (SPH) associated with these underlying causes: 4 angiomyolipomas, 2 renal cell carcinomas, 1 renal metastatic malignant melanoma, 1 ruptured renal artery aneurysm, 1 adrenal myelolipoma, 1 ruptured renal abscess, 2 ruptured hemorrhagic cysts, and 1 patient with undiagnosed coagulation disorder. Our objective was to ascertain whether an underlying cause of SPH was identifiable by CT, and to determine the extension of the hematomas. Computed tomography identified the hematoma in all 13 cases (sensitivity 100 %). In all 12 cases in which there was a renal or adrenal anatomic lesion, the underlying cause was identified with CT (100 %), with correct diagnosis in 11 cases (91.6 %). The case in which no lesion was identified was the undiagnosed coagulation disorder. We conclude that CT is a useful technique for the initial evaluation of SPH, permitting diagnosis of hemorrhage and identification of the underlying cause. (orig.). With 6 figs., 1 tab.

  4. Post transplant lymphoproliferative disease in pediatric solid organ transplant patients: A possible role for [{sup 18}F]-FDG-PET(/CT) in initial staging and therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Falck, C. von [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany)], E-mail: Falck.Christian.von@mh-hannover.de; Maecker, B. [Department of Pediatric Hematology and Oncology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Schirg, E. [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Boerner, A.R.; Knapp, W.H. [Department of Nuclear Medicine, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Klein, C. [Department of Pediatric Hematology and Oncology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Galanski, M. [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany)

    2007-09-15

    Post transplant lymphoproliferative disease (PTLD) is a severe complication after solid organ or bone marrow transplantation. In pediatric transplant recipients PTLD is the most common malignancy. The aim of this study was to evaluate a possible role for positron emission tomography with [{sup 18}F]-2-fluoro-2-desoxy-glucose (FDG) in the initial staging and in therapy monitoring of pediatric patients suffering from biopsy-proven CD20-positive PTLD after solid organ transplantation. Seven pediatric patients were included. All available imaging studies - CT (n = 15), MRI (n = 16) and PET/PETCT (n = 16) - were reviewed on a lesion by lesion base. The performance of FDG-PET in the initial staging and during therapy with a chimeric anti-CD20 antibody was compared to conventional cross sectional imaging and correlated with the clinical outcome. FDG-PET identified all sites of disease as shown by CT/MRI and helped to clarify the significance of equivocal findings. The initial stage of disease was correctly identified by FDG-PET alone when compared to CT/MRI. During therapy, FDG-PET was superior to conventional cross-sectional imaging in the early evaluation of response.

  5. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  6. 18FDG uptake associated with CT density on PET/CT in lungs with and without chronic interstitial lung diseases

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Okada, Ken; Taki, Yasuyuki; Goto, Ryoi; Kinomura, Shigeo; Fukuda, Hiroshi

    2009-01-01

    The dependent-density of computed tomography (CT) images of positron emission tomography (PET)/CT is sometimes difficult to distinguish from chronic interstitial lung disease (ILD) when it accompanies increased 18 F-fluorodeoxy-D-glucose ( 18 FDG) uptake. Though the possible utility of 18 FDG-PET for the diagnosis of active ILD has been reported, the clinical relevance of mild lung 18 FDG uptake in ILD cases without signs and symptoms suggesting acute progression has not been described. This study aimed to test relationships between 18 FDG uptake and lung density on CT using PET/CT in patients with normal lung as well as clinically stable chronic ILD. Thirty-six patients with normal lungs (controls) and 28 patients with chronic ILD (ILD cases) without acute exacerbation were retrospectively selected from 18 FDG PET/CT scans performed in examination of malignant neoplasms. Elliptical regions of interest (ROIs) were placed on the lung. The relationships between CT density and 18 FDG uptake between the control and ILD cases were tested. The CT density and 18 FDG uptake had a linear correlation in both the controls and the ILD cases without a difference in their regression slopes, and they were overlapped between the controls and the ILD cases with higher mean values in the ILD cases. Lung 18 FDG uptake was considered to reflect a gravity-dependent tissue density in the normal lung. Though the lung 18 FDG uptake as well as the CT density tended to be higher in chronic ILD patients, it may be difficult to distinguish them in normal dependent regions from those related to chronic ILD in some cases. (author)

  7. Significance of 18F-FDG PET/CT imaging in the evaluation of the efficacy of lymphoma

    Institute of Scientific and Technical Information of China (English)

    CHEN Chengcheng; WANG Zhengguang; CHENG Nan

    2014-01-01

    To evaluate the 18F-labeled deoxyglucose (18F-FDG) PET/CT imaging in the evaluation of the efficacy of ly-mphoma significance.Methods:42 cases of our hospital patients with malignant lymphoma for 2-5 times 18F-FDG PET/CT imaging results in the treatment process, and the treatment process simple CT results were compared and analyzed, the final results were confirmed by pathology and clinical. Results:The lesions were found in153,including 141 malignant, benign 12, sensitivity, specificity, and accuracy evaluating of lymphoma treatment effect of 18F-FDG PET/CT were, 99.30%, 91.67%, 98.70%, were significantly better than CT examination (PCT in the evaluation of ly-mphoma treatment was superior to CT scan purely, it is an effective means of monitoring the efficacy of lymphoma, it can provide the basis for effective treatment programs in clinical work.

  8. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CTCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CTCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  9. Clinical usefulness of multidetector-row CT to evaluate coronary artery calcium score in type 2 diabetes

    International Nuclear Information System (INIS)

    Nishioka, Makiko; Sakuma, Toru; Sano, Hironari; Utsunomiya, Kazunori; Agata, Toshihiko; Shimizu, Keisuke; Tajima, Naoko

    2004-01-01

    According to recent studies, multidetector-row CT (MDCT) with a retrospective electrocardiogram (ECG)-gating reconstruction algorithm shows a high correlation with coronary artery calcium score determined using electron-beam CT. Diabetes leads to many macrovascular complications, including coronary artery disease. The aim of this study was to evaluate risk factors for cardiac macroangiopathy in type 2 diabetes using MDCT. An observational cross-sectional study was performed in 90 patients with diabetes mellitus. Coronary calcium data was acquired by MDCT (SOMATOM Volume Zoom, Siemens AG, Medical Solutions, Germany). Physical examinations, laboratory data, glycemic control, and control of other risk factors were analyzed. The coronary artery calcium score increased with age. Multivariant analysis revealed that the coronary calcium score was closely correlated with electrocardiogram evaluation and control of hypertension. Coronary artery calcium score as determined by MDCT can be used as a screening radiological examination for cardiac macroangiopathy in diabetes patients with electrocardiogram abnormality and hypertension. (author)

  10. Restaging oesophageal cancer after neoadjuvant therapy with {sup 18}F-FDG PET-CT: identifying interval metastases and predicting incurable disease at surgery

    Energy Technology Data Exchange (ETDEWEB)

    Findlay, John M. [Churchill Hospital, Oxford OesophagoGastric Centre, Oxford (United Kingdom); Churchill Hospital, NIHR Oxford Biomedical Research Centre, Oxford (United Kingdom); Gillies, Richard S.; Maynard, Nicholas D. [Churchill Hospital, Oxford OesophagoGastric Centre, Oxford (United Kingdom); Franklin, James M.; Teoh, Eugene J.; Gleeson, Fergus V.; Bradley, Kevin M. [Churchill Hospital, Department of Nuclear Medicine, Oxford (United Kingdom); Jones, Greg E. [Churchill Hospital, Oxford OesophagoGastric Centre, Oxford (United Kingdom); Royal Berkshire Hospital, Reading (United Kingdom); Di Carlo, Sara [Churchill Hospital, Oxford OesophagoGastric Centre, Oxford (United Kingdom); Queen' s Medical Centre, Nottingham (United Kingdom); Middleton, Mark R. [Churchill Hospital, NIHR Oxford Biomedical Research Centre, Oxford (United Kingdom)

    2016-10-15

    It is unknown whether restaging oesophageal cancer after neoadjuvant therapy with positron emission tomography-computed tomography (PET-CT) is more sensitive than contrast-enhanced CT for disease progression. We aimed to determine this and stratify risk. This was a retrospective study of patients staged before neoadjuvant chemotherapy (NAC) by {sup 18}F-FDG PET-CT and restaged with CT or PET-CT in a single centre (2006-2014). Three hundred and eighty-three patients were restaged (103 CT, 280 PET-CT). Incurable disease was detected by CT in 3 (2.91 %) and PET-CT in 17 (6.07 %). Despite restaging unsuspected incurable disease was encountered at surgery in 34/336 patients (10.1 %). PET-CT was more sensitive than CT (p = 0.005, McNemar's test). A new classification of FDG-avid nodal stage (mN) before NAC (plus tumour FDG-avid length) predicted subsequent progression, independent of conventional nodal stage. The presence of FDG-avid nodes after NAC and an impassable tumour stratified risk of incurable disease at surgery into high (75.0 %; both risk factors), medium (22.4 %; either), and low risk (3.87 %; neither) groups (p < 0.001). Decision theory supported restaging PET-CT. PET-CT is more sensitive than CT for detecting interval progression; however, it is insufficient in at least higher risk patients. mN stage and response (mNR) plus primary tumour characteristics can stratify this risk simply. (orig.)

  11. Restaging oesophageal cancer after neoadjuvant therapy with "1"8F-FDG PET-CT: identifying interval metastases and predicting incurable disease at surgery

    International Nuclear Information System (INIS)

    Findlay, John M.; Gillies, Richard S.; Maynard, Nicholas D.; Franklin, James M.; Teoh, Eugene J.; Gleeson, Fergus V.; Bradley, Kevin M.; Jones, Greg E.; Di Carlo, Sara; Middleton, Mark R.

    2016-01-01

    It is unknown whether restaging oesophageal cancer after neoadjuvant therapy with positron emission tomography-computed tomography (PET-CT) is more sensitive than contrast-enhanced CT for disease progression. We aimed to determine this and stratify risk. This was a retrospective study of patients staged before neoadjuvant chemotherapy (NAC) by "1"8F-FDG PET-CT and restaged with CT or PET-CT in a single centre (2006-2014). Three hundred and eighty-three patients were restaged (103 CT, 280 PET-CT). Incurable disease was detected by CT in 3 (2.91 %) and PET-CT in 17 (6.07 %). Despite restaging unsuspected incurable disease was encountered at surgery in 34/336 patients (10.1 %). PET-CT was more sensitive than CT (p = 0.005, McNemar's test). A new classification of FDG-avid nodal stage (mN) before NAC (plus tumour FDG-avid length) predicted subsequent progression, independent of conventional nodal stage. The presence of FDG-avid nodes after NAC and an impassable tumour stratified risk of incurable disease at surgery into high (75.0 %; both risk factors), medium (22.4 %; either), and low risk (3.87 %; neither) groups (p < 0.001). Decision theory supported restaging PET-CT. PET-CT is more sensitive than CT for detecting interval progression; however, it is insufficient in at least higher risk patients. mN stage and response (mNR) plus primary tumour characteristics can stratify this risk simply. (orig.)

  12. Intramuscular ganglia arising from the superior tibiofibular joint: CT and MR evaluation

    International Nuclear Information System (INIS)

    Bianchi, S.; Abdelwahab, I.F.; Kenan, S.; Zwass, A.; Ricci, G.; Palomba, G.

    1995-01-01

    To evaluate the role of magnetic resonance imaging (MRI) and computed tomography (CT) in the diagnosis of intramuscular ganglia (IMG) that arise from the superior tibiofibular joint (STFJ). Our series consisted of three men and three women. Four patients were studied by MRI, one by CT only, and two by both modalities. Contrast was used in one of the two patients studied by CT. MRI was obtained in at least two orthogonal planes to demonstrate the relation of the ganglia to STFJ. The MR and CT appearance of these ganglia was basically that of a well-defined soft tissue mass with low attenuation on CT images consistent with the presence of fluid. On MR studies, they had an isointense signal on T1-weighted images and a homogenous high-intensity signal on T2-weighted images. MRI demonstrated the attachment of these ganglia to the STFJ. CT and MRI were effective, noninvasive modalities in the evaluation of IMG. The imaging features on both modalities were consistent with the presence of fluid-containing lesions that had close proximity and were attached to the STFJ. The combination of location and the fluid consistency of these lesions facilitated the diagnosis. (orig.)

  13. 18F-FDG PET/CT in follow-up evaluation in pediatric patients with Langerhans histiocytosis.

    Science.gov (United States)

    Garcia, J R; Riera, E; Bassa, P; Mourelo, S; Soler, M

    We evaluated the impact of 18 F-FDG PET/CT in identifying sites of active disease and to assess therapeutic follow up in a group of pediatric patients with Langerhans cell histiocytosis (LCH). During 2007-2013, 13 18 F-FDG PET/CT studies were performed for follow-up in 7 patients with a diagnosis of LCH (4 female, 3 male; 1-12 years-old). PET findings were analyzed and correlated with the CT and MRI. Findings were also follow-up by these techniques. PET was negative in 4 patients (all diagnosed with bone lesions and one with pituitary involvement also). CT findings showed residual morphological bone lesions in all patients, and hypophysis MRI study showed no abnormal signal. PET remained negative at 10, 14, 25 and 28 months, and no new lesions on CT and MRI were detected. PET was positive in 3 patients (one with cervical lymphadenopathy and 2 with bone lesions, one also with pituitary involvement not identified by PET). CT findings showed pathological cervical lymphadenopathy (n=1), bone lesions (n=2) and also a pituitary MRI lesion (n=1). In a patient with cervical lymphadenopathy histology demonstrated LCH involvement. In the other 2 patients, PET remained positive with an increase of 18 F-FDG bone uptake at 17 and 19 months. In our preliminar study, 18 F-FDG PET is a useful imaging procedure, along with other diagnostic tools, for identification of active lesions. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  15. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  16. Comparison of FDG-PET/CT and contrast-enhanced CT for monitoring therapy response in patients with metastatic breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Riedl, Christopher C.; Ulaner, Gary A.; Jochelson, Maxine S.; Weber, Wolfgang A. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Pinker, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ong, Leonard T. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Baltzer, Pascal [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); McArthur, Heather L. [Cedars-Sinai Medical Center, Department of Medicine, Breast Oncology, Los Angeles, CA (United States); Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Dickler, Maura [Memorial Sloan Kettering Cancer Center, Department of Medicine, New York, NY (United States)

    2017-08-15

    The aim of this study was to compare fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and contrast-enhanced computed tomography (CE-CT) for the prediction of progression-free survival (PFS) and disease-specific survival (DSS) in patients with stage IV breast cancer undergoing systemic therapy. Sixty-five patients with metastatic breast cancer treated with first- or second-line systemic therapy in prospective clinical trials were included. Response to treatment was evaluated by Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 for CE-CT and by PET Response Criteria in Solid Tumors (PERCIST), respectively. All responders by RECIST (n = 22) were also responders by PERCIST, but 40% (17/43) of non-responders by RECIST were responders by PERCIST. Responses according to RECIST and PERCIST both correlated with PFS, but PERCIST showed a significantly higher predictive accuracy (concordance index for PFS: 0.70 vs. 0.60). One-year PFS for responders vs. non-responders by RECIST was 59% vs. 27%, compared to 63% vs. 0% by PERCIST. Four-year DSS of responders and non-responders by RECIST was 50% and 38%, respectively (p = 0.2, concordance index: 0.55) as compared to 58% vs. 18% for PERCIST (p < 0.001, concordance index: 0.65). Response on PET/CT was also a significantly better predictor for DSS than disease control on CE-CT. In patients with metastatic breast cancer, tumor response on PET/CT appears to be a superior predictor of PFS and DSS than response on CE-CT. Monitoring tumor response by PET/CT may increase the power of clinical trials using tumor response as an endpoint, and may improve patient management in clinical routine. (orig.)

  17. Lumbar CT findings of patients with low back pain

    International Nuclear Information System (INIS)

    Lee, Yong Chul; Kim, Yang Soo; Kim, Kyun Sang

    1986-01-01

    Low back pain is probably the second most common disease entity to upper respiratory infection in developed country. We were missing at least 50% of the pathologic conditions by using conventional diagnostic modalities in low back pain. They did tell us nothing or little about facet abnormalities, lateral recesses, vertebral canal and soft tissue surrounding lumbar spines. High resolutional CT has been the biggest turning point in the diagnosis and management of low back pain. CT make a contribution to reducing the morbidity and probably the cost of evaluating patients with low back pain, and to increasing diagnostic accuracy. We observed 100 cases of lumbar CT using TCT 80A scanner for the evaluation of low back pain during the period from Apr. 1985 to Sept. 1985 at Chung-Ang University Hospital. Lumbar CT scan reveals high-positive findings (98%) in low back pain patients. Common low back disorders in CT are disc bulging (53%), herniated nucleus pulposus (32%), degenerative arthritis in posterior facet joints (27%), spinal stenosis (20%) and postoperative spines (15%). Uncommon low back disorders in CT are compression fracture of vertebral bodies, spondylolysis or spondylolisthesis, tropism, transitional vertebra, Scheueman's disease, limbic fracture, transverse process or articular process fracture, sacroiliac joint subluxation, conjoined nerve root and meningocele.

  18. Lumbar CT findings of patients with low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Chul; Kim, Yang Soo; Kim, Kyun Sang [Chung-Ang University, Seoul (Korea, Republic of)

    1986-04-15

    Low back pain is probably the second most common disease entity to upper respiratory infection in developed country. We were missing at least 50% of the pathologic conditions by using conventional diagnostic modalities in low back pain. They did tell us nothing or little about facet abnormalities, lateral recesses, vertebral canal and soft tissue surrounding lumbar spines. High resolutional CT has been the biggest turning point in the diagnosis and management of low back pain. CT make a contribution to reducing the morbidity and probably the cost of evaluating patients with low back pain, and to increasing diagnostic accuracy. We observed 100 cases of lumbar CT using TCT 80A scanner for the evaluation of low back pain during the period from Apr. 1985 to Sept. 1985 at Chung-Ang University Hospital. Lumbar CT scan reveals high-positive findings (98%) in low back pain patients. Common low back disorders in CT are disc bulging (53%), herniated nucleus pulposus (32%), degenerative arthritis in posterior facet joints (27%), spinal stenosis (20%) and postoperative spines (15%). Uncommon low back disorders in CT are compression fracture of vertebral bodies, spondylolysis or spondylolisthesis, tropism, transitional vertebra, Scheueman's disease, limbic fracture, transverse process or articular process fracture, sacroiliac joint subluxation, conjoined nerve root and meningocele.

  19. Clinical value of surgical staging with preoperative 18F-FDG PET/CT evaluation for mediastinal lymph nodes in lung cancer

    International Nuclear Information System (INIS)

    Li Hong; Wang Xiaoming; Xu Weina; Xin Jun; Guo Qiyong

    2012-01-01

    Objective: To investigate the clinical value of preoperative 18 F-FDG PET/CT for surgical staging by evaluating mediastinal lymphadenopathy in lung cancer. Methods: Sixty-eight patients with lung cancer underwent both 18 F-FDG PET/CT and chest CT. The results of PET/CT and CT were compared with pathological results. χ 2 and t tests were used for data analysis. Results: A total of 222 mediastinal lymph nodes were resected in 68 patients and 84 (37.8%) were confirmed as metastases by pathology. The sensitivity, specificity, accuracy, positive and negative predictive values for PET/CT and CT were 71.4% (60/84) vs 48.8% (41/84), 66.7% (92/138) vs 49.3% (68/138), 68.5% (152/222) vs 49.1%(109/222), 56.6% (60/106) vs 36.9% (41/111), 79.3% (92/116) vs 61.3 % (68/111), respectively (χ 2 =8.96, 8.57, 17.19, 8.43, 8.88, all P<0.05). The staging consistency of PET/CT with pathology was 73.5% (50/68), which was significantly higher than that of CT with pathology (41.2% (28/68); χ 2 =14.55, P<0.01). The identification of N 1 and N 2 disease was, respectively, 66.7%(10/15) and 79.2% (19/24) by PET/CT, 13.3%(2/15) and 45.8% (11/24) by CT (χ 2 =8.89 and 5.69, both P<0.05). The SUV max of lymph nodes greater than and equal to 10 mm in short diameter was significantly higher than those with short diameters less than 10 mm (5.5±2.8 vs 2.2±0.9, t=5.17, P<0.05). Conclusion: Preoperative 18 F-FDG PET/CT is more accurate for evaluating mediastinal lymphadenopathy and staging in patients with lung cancer than CT, and therefore is more valuable for optimizing the best treatment strategies. (authors)

  20. CT of the chest in the evaluation of idiopathic pulmonary arterial hypertension in children

    Energy Technology Data Exchange (ETDEWEB)

    Chaudry, Gulraiz [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Children' s Hospital Boston, Department of Radiology, Boston, MA (United States); MacDonald, Cathy; Gundogan, Munire; Manson, David [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Adatia, Ian [UCSF Children' s Hospital, Department of Pediatric Cardiology, San Francisco, CA (United States)

    2007-04-15

    Idiopathic pulmonary arterial hypertension (IPAH) is a rare disease in children. By definition it is a diagnosis of exclusion, and CT of the chest is primarily performed to exclude other causes. Previous studies have defined CT features suggestive of the diagnosis of IPAH, but these have all been limited to the adult population. Contrast-enhanced chest CT and high-resolution CT findings in IPAH were evaluated in an attempt to define features consistently seen in children with this condition. The chest CT scans performed at initial presentation were reviewed in 17 children with echocardiographic or angiographic evidence of IPAH. There were nine boys and eight girls, ranging in age from 1 month to 17 years. The extrapulmonary findings included cardiomegaly with right-sided cardiac enlargement, which was seen in 13 children. The central pulmonary arteries were enlarged in 15 children, with peripheral enlargement in two. In six children this resulted in bronchial compression. In addition, mediastinal and hilar lymphadenopathy was noted in three children. Prominent intrapulmonary features included a peripheral vasculopathy, with enlarged tortuous vessels, seen in eight children. Ill-defined ground-glass centrilobular opacities were also noted in eight children, representing the most common parenchymal abnormality. Other findings included septal lines in five, diffuse ground-glass opacification in four and focal hyperlucent zones in three. Mosaic attenuation was seen in one child. A variety of imaging findings are identified in IPAH. Features particularly consistent with the diagnosis include peripheral vasculopathy and centrilobular opacities in the setting of cardiomegaly and central pulmonary arterial enlargement. (orig.)

  1. CT of the chest in the evaluation of idiopathic pulmonary arterial hypertension in children

    International Nuclear Information System (INIS)

    Chaudry, Gulraiz; MacDonald, Cathy; Gundogan, Munire; Manson, David; Adatia, Ian

    2007-01-01

    Idiopathic pulmonary arterial hypertension (IPAH) is a rare disease in children. By definition it is a diagnosis of exclusion, and CT of the chest is primarily performed to exclude other causes. Previous studies have defined CT features suggestive of the diagnosis of IPAH, but these have all been limited to the adult population. Contrast-enhanced chest CT and high-resolution CT findings in IPAH were evaluated in an attempt to define features consistently seen in children with this condition. The chest CT scans performed at initial presentation were reviewed in 17 children with echocardiographic or angiographic evidence of IPAH. There were nine boys and eight girls, ranging in age from 1 month to 17 years. The extrapulmonary findings included cardiomegaly with right-sided cardiac enlargement, which was seen in 13 children. The central pulmonary arteries were enlarged in 15 children, with peripheral enlargement in two. In six children this resulted in bronchial compression. In addition, mediastinal and hilar lymphadenopathy was noted in three children. Prominent intrapulmonary features included a peripheral vasculopathy, with enlarged tortuous vessels, seen in eight children. Ill-defined ground-glass centrilobular opacities were also noted in eight children, representing the most common parenchymal abnormality. Other findings included septal lines in five, diffuse ground-glass opacification in four and focal hyperlucent zones in three. Mosaic attenuation was seen in one child. A variety of imaging findings are identified in IPAH. Features particularly consistent with the diagnosis include peripheral vasculopathy and centrilobular opacities in the setting of cardiomegaly and central pulmonary arterial enlargement. (orig.)

  2. CT in meningitis purulenta

    International Nuclear Information System (INIS)

    Yoshida, Akira; Fujiwara, Katsuhiko; Iino, Shigeru; Ochi, Masaharu; Yoshioka, Hiroshi

    1982-01-01

    Twenty nine infants with meningitis purulenta were classified into 5 groups according to CT findings in the acute stage: cerebral infarction group, subdural hygroma group, ventricular enlargement group, and a group of other diseases. In each group, clinical findings, surgical procedures and prognosis were evaluated. In the cerebral infarction group, although 3 of 4 patients underwent V-P shunt or subdural drainage, remarkable sequelae were found in all the cases. Of 4 subdural hygroma patients, 2 had subdural drainage, and 4 of 8 patients with ventricular enlargement underwent V-P shunt. All the patients of the two groups had favorable prognosis without any sequela. A patient with cerebral herniation in the group of other diseases died in its acute stage. Eleven infants without abnormal CT findings showed normal psychomotor development. (Ueda, J.)

  3. Clinical value of FDG PET/CT in the diagnosis of suspected recurrent ovarian cancer: is there an impact of FDG PET/CT on patient management?

    International Nuclear Information System (INIS)

    Bilici, Ahmet; Ustaalioglu, Bala Basak Oven; Seker, Mesut; Salepci, Taflan; Gumus, Mahmut; Canpolat, Nesrin; Tekinsoy, Bulent

    2010-01-01

    The aim of this study was to evaluate the clinical value of FDG PET/CT in patients with suspected ovarian cancer recurrence as compared with diagnostic CT, and to assess the impact of the results of FDG PET/CT on treatment planning. Included in this retrospective study were 60 patients with suspected recurrent ovarian cancer who had previously undergone primary debulking surgery and had been treated with adjuvant chemotherapy. Diagnostic CT and FDG PET/CT imaging were performed for all patients as clinically indicated. The changes in the clinical management of patients according to the results of FDG PET/CT were also analysed. FDG PET/CT was performed in 21 patients with a previously negative or indeterminate diagnostic CT scan, but an elevated CA-125 level, and provided a sensitivity of 95% in the detection of recurrent disease. FDG PET/CT revealed recurrent disease in 19 patients. In 17 of 60 patients, the indication for FDG PET/CT was an elevated CA-125 level and an abnormal diagnostic CT scan to localize accurately the extent of disease. FDG PET/CT scans correctly identified recurrent disease in 16 of the 17 patients, a sensitivity of 94.1%. Moreover, FDG PET/CT was performed in 18 patients with clinical symptoms of ovarian cancer recurrence, an abnormal diagnostic CT scan, but a normal CA-125 level. In this setting, FDG PET/CT correctly confirmed recurrent disease in seven patients providing a sensitivity of 100% in determining recurrence. In four patients, FDG PET/CT was carried out for the assessment of treatment response. Three of four scans were classified as true-negative indicating a complete response. In the other patient, FDG PET/CT identified progression of disease. In total, 45 (75%) of the 60 patients had recurrent disease, in 14 (31.1%) documented by histopathology and in 31 (68.9%) on clinical follow-up, while 15 (25%) had no evidence of recurrent disease. The overall sensitivity, specificity, accuracy, and positive and negative predictive value

  4. Technical Evaluation Report 41: WebCT: A major shift of emphasis

    Directory of Open Access Journals (Sweden)

    Kristine Thibeault

    2004-11-01

    Full Text Available The evaluation reports in this series usually feature several products at once. The current review, however, comes at a time when one of the most widely used (and expensive online learning management systems is undergoing a major change in its marketing strategy and corporate focus. WebCT is currently evolving to a new version (WebCT Vista, with much attendant discussion by distance education (DE users. The current review, as the others in this series, adds the DE student's perspective to this discussion. The review compares the existing WebCT Campus Edition with the new WebCT Vista, and examines some of the problems associated with the migration to Vista at the institutional level. A response to the report by the WebCT company is appended.

  5. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  6. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  7. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    International Nuclear Information System (INIS)

    Guy, Stephen D.; Tramontana, Adrian R.; Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A.; Lau, Eddie; Hicks, Rodney J.; Seymour, John F.

    2012-01-01

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [ 18 F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature ≥38 C and neutrophil count <500 cells/μl for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/μl (range 0-730 cells/μl). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  8. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Stephen D.; Tramontana, Adrian R. [Western Health, Department of Infectious Diseases, Private Bag, Footscray, Victoria (Australia); University of Melbourne, Parkville, Victoria (Australia); Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Infectious Diseases, Melbourne, Victoria (Australia); Lau, Eddie; Hicks, Rodney J. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Centre for Cancer Imaging, Melbourne, Victoria (Australia); Seymour, John F. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Haematology, Melbourne, Victoria (Australia)

    2012-08-15

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [{sup 18} F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature {>=}38 C and neutrophil count <500 cells/{mu}l for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/{mu}l (range 0-730 cells/{mu}l). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  9. Quantification of neonatal lung parenchymal density via ultrashort echo time MRI with comparison to CT.

    Science.gov (United States)

    Higano, Nara S; Fleck, Robert J; Spielberg, David R; Walkup, Laura L; Hahn, Andrew D; Thomen, Robert P; Merhar, Stephanie L; Kingma, Paul S; Tkach, Jean A; Fain, Sean B; Woods, Jason C

    2017-10-01

    To demonstrate that ultrashort echo time (UTE) magnetic resonance imaging (MRI) can achieve computed tomography (CT)-like quantification of lung parenchyma in free-breathing, non-sedated neonates. Because infant CTs are used sparingly, parenchymal disease evaluation via UTE MRI has potential for translational impact. Two neonatal control cohorts without suspected pulmonary morbidities underwent either a research UTE MRI (n = 5; 1.5T) or a clinically-ordered CT (n = 9). Whole-lung means and anterior-posterior gradients of UTE-measured image intensity (arbitrary units, au, normalized to muscle) and CT-measured density (g/cm 3 ) were compared (Mann-Whitney U-test). Separately, a diseased neonatal cohort (n = 5) with various pulmonary morbidities underwent both UTE MRI and CT. UTE intensity and CT density were compared with Spearman correlations within ∼33 anatomically matched regions of interest (ROIs) in each diseased subject, spanning low- to high-density tissues. Radiological classifications were evaluated in all ROIs, with mean UTE intensities and CT densities compared in each classification. In control subjects, whole-lung UTE intensities (0.51 ± 0.04 au) were similar to CT densities (0.44 ± 0.09 g/cm 3 ) (P = 0.062), as were UTE (0.021 ± 0.020 au/cm) and CT (0.034 ± 0.024 [g/cm 3 ]/cm) anterior-posterior gradients (P = 0.351). In diseased subjects' ROIs, significant correlations were observed between UTE and CT (P ≤0.007 in each case). Relative differences between UTE and CT were small in all classifications (4-25%). These results demonstrate a strong association between UTE image intensity and CT density, both between whole-lung tissue in control patients and regional radiological pathologies in diseased patients. This indicates the potential for UTE MRI to longitudinally evaluate neonatal pulmonary disease and to provide visualization of pathologies similar to CT, without sedation/anesthesia or ionizing radiation

  10. A scientific update on biosimilar infliximab (CT-P13) in rheumatic diseases.

    Science.gov (United States)

    Taylor, Peter

    2015-01-01

    The development of biologic drugs has undoubtedly enhanced the spectrum of treatments available for immune-mediated inflammatory rheumatic diseases such as rheumatoid arthritis. However, despite their clear clinical benifits, use of biologics is often hindered by their high costs. The manufacture and subsequent approval of more cost-effective 'biosimilar' versions of these drugs may address this issue and improve patient access. CT-P13 (Remsima(®), Inflectra(®)), a biosimilar of infliximab (Remicade(®)), has shown comparable efficacy, safety and pharmacokinetics to its originator drug in clinical studies. The articles in this supplement present a scientific update on the development and use of biosimilars in rheumatic disorders, with specific focus on CT-P13. The information discussed highlights the predicted positive clinical and economic impact of biosimilars on the management of rheumatic diseases.

  11. Primary staging of laryngeal and hypopharyngeal cancer: CT, MR imaging and dual-energy CT

    International Nuclear Information System (INIS)

    Kuno, Hirofumi; Onaya, Hiroaki; Fujii, Satoshi; Ojiri, Hiroya; Otani, Katharina; Satake, Mitsuo

    2014-01-01

    Laryngeal and hypopharyngeal cancer, in particular T4a disease associated with cartilage invasion and extralaryngeal spread, needs to be evaluated accurately because treatment can impact heavily on a patient's quality of life. Reliable imaging tools are therefore indispensible. CT offers high spatial and temporal resolution and remains the preferred imaging modality. Although cartilage invasion can be diagnosed with acceptable accuracy by applying defined criteria for combinations of erosion, lysis and transmural extralaryngeal spread, iodine-enhanced tumors and non-ossified cartilage are sometimes difficult to distinguish. MR offers high contrast resolution for images without motion artifacts, although inflammatory changes in cartilage sometimes resemble cartilage invasion. With dual-energy CT, combined iodine overlay images and weighted average images can be used for evaluation of cartilage invasion, since iodine enhancement is evident in tumor tissue but not in cartilage. Extralaryngeal spread can be evaluated from CT, MR or dual-energy CT images and the routes of tumor spread into the extralaryngeal soft tissue must be considered; (1) via the thyrohyoid membrane along the superior laryngeal neurovascular bundle, (2) via the inferior pharyngeal constrictor muscle, and (3) via the cricothyroid membrane. Radiologists need to understand the advantages and limitations of each imaging modality for staging of laryngeal and hypopharyngeal cancer

  12. The usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region

    International Nuclear Information System (INIS)

    Grzesiakowska, U.; Tacikowska, M.; Krajewski, R.; Starosciak, S.; Smorczewska, M.; Wiszniewska-Rawlik, D.

    2005-01-01

    The aim of the study was to determine the usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region. All the patients were treated surgically. CT and/or MR imaging was done in every patient for preoperative evaluation of soft tissue infiltration, destruction of bone structures, and metastasis of lymph nodes of the head and neck. The results of these imagings were compared with surgical evaluations and microscopic examination of postoperative specimens. Both CT and MR imaging have high accuracy in evaluating soft tissue infiltration. CT imaging is much better than MR in evaluating bony destruction. MR imaging is better in evaluating recurrent tumors, in which CT has very low specificity. MR imaging is the only method for evaluating infiltration of the central nervous system.The authors propose the following diagnostic algorithm: CT imaging for initial evaluation before treatment, MR imaging in suspected cases of infiltration of the central nervous system, and MR imaging in recurrent tumors after surgical and radiation treatment. (author)

  13. Initial use of fast switched dual energy CT for coronary artery disease

    Science.gov (United States)

    Pavlicek, William; Panse, Prasad; Hara, Amy; Boltz, Thomas; Paden, Robert; Yamak, Didem; Licato, Paul; Chandra, Naveen; Okerlund, Darin; Dutta, Sandeep; Bhotika, Rahul; Langan, David

    2010-04-01

    Coronary CT Angiography (CTA) is limited in patients with calcified plaque and stents. CTA is unable to confidently differentiate fibrous from lipid plaque. Fast switched dual energy CTA offers certain advantages. Dual energy CTA removes calcium thereby improving visualization of the lumen and potentially providing a more accurate measure of stenosis. Dual energy CTA directly measures calcium burden (calcium hydroxyapatite) thereby eliminating a separate non-contrast series for Agatston Scoring. Using material basis pairs, the differentiation of fibrous and lipid plaques is also possible. Patency of a previously stented coronary artery is difficult to visualize with CTA due to resolution constraints and localized beam hardening artifacts. Monochromatic 70 keV or Iodine images coupled with Virtual Non-stent images lessen beam hardening artifact and blooming. Virtual removal of stainless steel stents improves assessment of in-stent re-stenosis. A beating heart phantom with 'cholesterol' and 'fibrous' phantom coronary plaques were imaged with dual energy CTA. Statistical classification methods (SVM, kNN, and LDA) distinguished 'cholesterol' from 'fibrous' phantom plaque tissue. Applying this classification method to 16 human soft plaques, a lipid 'burden' may be useful for characterizing risk of coronary disease. We also found that dual energy CTA is more sensitive to iodine contrast than conventional CTA which could improve the differentiation of myocardial infarct and ischemia on delayed acquisitions. These phantom and patient acquisitions show advantages with using fast switched dual energy CTA for coronary imaging and potentially extends the use of CT for addressing problem areas of non-invasive evaluation of coronary artery disease.

  14. CT-sialographic evaluation of 19 cases of alivary gland tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tadashi [Komoro Kousei General Hospital, Nagano (Japan)

    1999-09-01

    Sixteen patients with parotid gland tumors and 3 patients with submandibular gland tumors were evaluated by CT sialography. The 19 patients were 5 to 78 years old, mean age: 57.3 years. CT sialography was performed preoperatively, and postoperative histological examination indicated that the tumors were benign in 13, a cyst in 1, malignant tumors in 4, and a malignant lymphoma in 1 patient. The tumorous lesion detection rate by CT sialography was 100%. The major duct was visualized in all patients, and the examination was informative about the special relationship between the tumor and the facial nerve. No sign of malignancy was noted in an epithelialmyoepithelial carcinoma of 10 mm in diameter on CT sialography. In 2 patients adhesion to surrounding tissues observed intraoperatively was judged to be benign tumors by CT sialography. The marginal morphology of the tumor and the presence or absence of low density areas and punctuate leakage in the interior of the tumor were useful for the judgement of malignancy of salivary gland tumors. CT sialography, which provides diverse information on the location and morphology of the tumor, should be performed early for the diagnosis of salivary gland tumors. (author)

  15. Learning with distribution of optimized features for recognizing common CT imaging signs of lung diseases

    Science.gov (United States)

    Ma, Ling; Liu, Xiabi; Fei, Baowei

    2017-01-01

    Common CT imaging signs of lung diseases (CISLs) are defined as the imaging signs that frequently appear in lung CT images from patients. CISLs play important roles in the diagnosis of lung diseases. This paper proposes a novel learning method, namely learning with distribution of optimized feature (DOF), to effectively recognize the characteristics of CISLs. We improve the classification performance by learning the optimized features under different distributions. Specifically, we adopt the minimum spanning tree algorithm to capture the relationship between features and discriminant ability of features for selecting the most important features. To overcome the problem of various distributions in one CISL, we propose a hierarchical learning method. First, we use an unsupervised learning method to cluster samples into groups based on their distribution. Second, in each group, we use a supervised learning method to train a model based on their categories of CISLs. Finally, we obtain multiple classification decisions from multiple trained models and use majority voting to achieve the final decision. The proposed approach has been implemented on a set of 511 samples captured from human lung CT images and achieves a classification accuracy of 91.96%. The proposed DOF method is effective and can provide a useful tool for computer-aided diagnosis of lung diseases on CT images.

  16. The usefulness of CT scanning in clinical observation on the patients with Alzheimer`s disease; Znaczenie tomografii komputerowej w obserwacji klinicznej pacjentow z choroba Alzheimera

    Energy Technology Data Exchange (ETDEWEB)

    Golebiowski, M; Barcikowska, M; Pfeffer-Baczuk, A; Luczywek, E [Akademia Medyczna, Warsaw (Poland)

    1994-12-31

    On the basis of brain CT studies of 150 patients of the clinic for persons with Alzheimer`s disease the diagnostic utility of measurement of hippocampal fissure and craniocerebral ratios was assessed. In analyzed group hippocampal fissure measurements greater than 4 mm occurred only in patients with symptoms of Alzheimer`s type dementia. The measurement showed 90% sensitivity and 70% specificity as the prognostic factor of clinical course, especially at the first part of the disease. The evaluation of the hippocampal fissure in conjunction with detailed analysis of CT picture of the atrophic brain allowed for precise final diagnosis. (author). 14 refs, 4 refs.

  17. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  18. CT diagnosis of simple renal cysts

    International Nuclear Information System (INIS)

    Nanakawa, Seito; Yasunaga, Tadamasa; Tsuchigame, Tadatoshi; Kawano, Shoji; Takahashi, Mutsumasa; Fukui, Koutaro.

    1987-01-01

    CT is indispensable in the evaluation of renal masses, providing noninvasive and clear transverse images. With wider clinical application of CT, renal cysts have been found more frequently. CT examinations on 500 patients, who underwent CT for the diagnosis of renal diseases except for renal cysts, have been reviewed and analysed. The incidence of renal cysts was 9.6 % without prediction for sexes, but the incidence and sizes of the cysts increased with the advancing age. The upper portion of the kidneys was more frequently involved, but there was no relationship between number, sex and age of the patients. Since renal cysts produce mass effect in the kidneys, understanding of the nature and incidence of the renal cysts is important in diagnosing renal mass lesions. (author)

  19. Magnetic resonance imaging (MRI) in diffuse liver diseases. Comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Masaharu; Ebara, Masaaki; Ohto, Masao

    1987-06-01

    MRI (Magnetic Resonance Imaging) was performed in 74 patients with chronic hepatitis, liver cirrhosis, idiopathic portal hypertension, Budd-Chiari syndrome, extrahepatic protal vein occlusion, Wilson disease and hemochromatosis. We measured relaxation time of the liver and the spleen in these patients and compared MRI with CT in the diagnostic capability. MRI was superior to plain CT in the detection of collateral vessels in liver cirrhosis and extrahepatic protal vein occlusion. MRI could also demonstrate the occluded part of the inferior vena cava in Budd-Chiari syndrome. However, MRI was almost the same as CT in the visualization of the hepatic configuration in liver cirrhosis. In liver cirrhosis, T1 values of the liver and the spleen were longer than those in normal controls, and T1 values of the liver were correlated with ICG R-15. Hepatic T1 values in Budd-Chiari syndrome were longer than those in normal controls.

  20. 111In-Pentetreotide SPECT/CT in Pulmonary Carcinoid.

    Science.gov (United States)

    Chiaravalloti, Agostino; Spanu, Angela; Danieli, Roberta; Dore, Francesca; Piras, Bastiana; Falchi, Antonio; Tavolozza, Mario; Madeddu, Giuseppe; Schillaci, Orazio

    2015-07-01

    We evaluated somatostatin receptor scintigraphy (SRS) with (111)In-pentetreotide incremental value in pulmonary carcinoid (PC) diagnosis compared to contrast enhanced Computed Tomography (ceCT). We enrolled 81 patients with ascertained PC, 39 at initial staging and 42 in follow-up; the primary tumor had already been excised in 68 cases. Single Photon emission Computed Tomography (SPECT) images were reconstructed with the iterative method and fused with non-enhanced Computed tomography (CT) images. Primary PC or metastatic lesions were ascertained in 55/81 patients and SPECT/CT was positive in 50/55 cases, while ceCT was positive in 44/55. Comparing SPECT/CT with ceCT results, we found a sensitivity of 96 vs. 87.5%, and specificity of 92% vs. 97% for the detection of primary lesion or recurrent disease. A total of 198 lesions were ascertained at SPECT/CT, while 161 at ceCT, with values of sensitivity and specificity of 85.5% and 84.6% for SRS and 75.2% and 90.5% respectively. (111)In-Pentetreotide SPECT/CT proved to be more sensitive and accurate than ceCT, thus enhancing its role in evaluating patients with PC. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  1. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  2. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  3. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  4. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee

    2009-01-01

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  5. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea); Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun [University of Ulsan College of Medicine, Department of Pediatric Cardiac Surgery, Asan Medical Center, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [University of Ulsan College of Medicine, Department of Pediatric Cardiology, Asan Medical Center, Seoul (Korea)

    2009-03-15

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  6. X-ray CT evaluation of pulmonary involvements of sarcoidosis

    International Nuclear Information System (INIS)

    Nishimura, Koichi; Izumi, Takateru; Kitaichi, Masanori

    1987-01-01

    We evaluated high resolution CT in 60 patients with histologically diagnosed pulmonary sarcoidosis and, also, studied the relationship between CT and findings in open lung biopsy specimens in 2 cases. The CT findings were as follows: (1) thickening of bronchial wall shadows (27 out of 60 cases, 45.0 %), (2) irregular enlargement of pulmonary vascular shadows (39 cases, 65.0 %), (3) small or large nodular shadows (24 cases, 40.0 %), (4) local volume loss (14 cases, 23.3 %), (5) slightly increased density of localized lung field areas (24 cases, 40.0 %), (6) pleural or subpleural involvement (27 cases, 45.0 %), (7) lymph node enlargement (59 cases, 98.3 %). X-ray CT in 7 patients revealed no evidence of lung field involvement in patients with histologicall confirmed epithelioid cell granuloma in transbronchial lung biopsy specimens. Lesions located within vessels or in the vascular wall, perivascular sheath or alveoli surrounding blood vessels might cause pulmonary vascular shadows to appear swollen on CT. In a comparative study, we found irregular dilatation of pulmonary vascular shadows corresponding to granulomas in the connective tissue sheath of blood vessels. Also, thickening of bronchial wall shadows corresponded to granulomas in and around the bronchial wall. From the point of histopathological view epithelioid cell granulomas in the bronchovascular sheath were most marked in sarcoidosis, and they apperaed on CT as an irregular enlargement of pulmonary vascular shadows and thickening of the bronchial wall. On the other hand, we reported that collapse of alveoli and fibrosis surrounding blood vessels could cause irregular enlargement of pulmonary vascular shadows on CT in idiopathic pulmonary fibrosis (IPF). Such shadows were seen on CT in both sarcoidosis and IPF but the mechanism of their appearance differed. (J.P.N.)

  7. A case of Addison's disease accompanied with bilateral adrenal calcification on CT

    International Nuclear Information System (INIS)

    Lee, Li-Chik; Fujita, Naohisa; Ohba, Yachiyo

    1985-01-01

    A 62-year-old woman was admitted to our hospital with complaints of general malaise and hyperpigmentation. We diagnosed her case as primary adrenocortical insufficiency (Addison's disease) by endocrinological studies. CT demonstrated dense calcification in both adrenal beds without evidence of normal glandular remnants. Calcified adrenal is not specific to tuberculosis, but some points of CT findings are useful for pathogenetic approach. Recently, there have been several reports that ACTH producing pituitary tumors develop in patients treated with conventional corticosteroid replacement. Corticosteroid should be administered by monitoring of plasma cortisol and ACTH concentrations. (author)

  8. Computed tomography in the evaluation of thyroid disease

    International Nuclear Information System (INIS)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-01-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum

  9. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  10. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  11. CT and MR urography

    International Nuclear Information System (INIS)

    Hadjidekov, G.

    2012-01-01

    Full text: Learning objectives:1) To describe the techniques of CT Urography and of MR urography; 2) To illustrate the benefit of the methods in clinical practice; 3)To present typical cases from the daily practice CT has become the mainstay of uroradiology in adults. CT urography is an excellent technique for the evaluation of urinary tract calculi, trauma, infections, complicated cysts, renal masses, having high sensitivity and specificity for both conditions facilitated by the possibilities for multiplanar imaging of the urinary system. It resembles excretory urography and consists of unenhanced, nephrographic, and pyelographic phases and can be used even as routine investigation. MR urography is a new, modern modality for evaluation of various urological abnormalities providing both morphological and functional information by means of different sequences with or without injection of gadolinium. The method is clinically useful in the evaluation of the collecting system, various variants and congenital abnormalities of the kidney, different cases of obstruction of the excretory system, tumors and inflammatory processes, hematuria. Compared to CT urography, MR urography is particularly beneficial in pediatric group or pregnant patients. It can also be performed in patients with renal insufficiency, iodine allergy and other cases of contraindications to the use of ionizing radiation. CT and MR urography are promising diagnostic methods of the wide spectrum of pathological conditions affecting the urinary tract. They are highly informative and overcome a lot of limitations of the other imaging modalities with the potential to become leading modalities to diagnose kidney diseases and other urogenital disorders.

  12. Selecting registration schemes in case of interstitial lung disease follow-up in CT

    International Nuclear Information System (INIS)

    Vlachopoulos, Georgios; Korfiatis, Panayiotis; Skiadopoulos, Spyros; Kazantzi, Alexandra; Kalogeropoulou, Christina; Pratikakis, Ioannis; Costaridou, Lena

    2015-01-01

    Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the

  13. Selecting registration schemes in case of interstitial lung disease follow-up in CT

    Energy Technology Data Exchange (ETDEWEB)

    Vlachopoulos, Georgios; Korfiatis, Panayiotis; Skiadopoulos, Spyros; Kazantzi, Alexandra [Department of Medical Physics, School of Medicine,University of Patras, Patras 26504 (Greece); Kalogeropoulou, Christina [Department of Radiology, School of Medicine, University of Patras, Patras 26504 (Greece); Pratikakis, Ioannis [Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi 67100 (Greece); Costaridou, Lena, E-mail: costarid@upatras.gr [Department of Medical Physics, School of Medicine, University of Patras, Patras 26504 (Greece)

    2015-08-15

    Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the

  14. PET/CT in staging and treatment response evaluation in lymphomas

    International Nuclear Information System (INIS)

    Bochev, P.

    2015-01-01

    Full text:The introduction of positron emission tomography (PET) and especially PET/CT with FDG in 2001 resulted in new concepts of overall management of patients with lymphoma and changed significantly the staging process and treatment response assessment. The considerable amount of literature and clinical trial data allowed leading cancer organizations like NCCN to incorporate in their current guidelines FDG-PET as a sole imaging modality in the management of Hodgkin‘s lymphoma, and an essential one in the management of FDG avid non-Hodgkin lymphoma (where indications vary based on particular histology). Main indications of FDG PET/CT in lymphoma are initial staging, restaging upon completion of therapy (EOT PET) and treatment response assessment. While staging with FDG and EOT PET restaging alone or combined with CECT have a straight-forward advantage over CT in evaluating small and borderline sized lymph nodes, bone marrow involvement and residual masses, treatment response assessment is rather challenging. By now and after long term trial evaluations, the response assessment is based on a visual assessment five point scale – Deauvillae criteria for response evaluation in HD and combined lugano criteria for NHL. The scale defines PET negative and PET positive cases as a presentation of responders versus non-responders which directly affects management. Although ESMO restricts the use of FDG-PET response evaluation in clinical trials only, NCCN go further, and bases its treatment recommendations on FDG-PET (Interim PET). Nowadays PET/CT is extensively used also in radiotherapy planning, which, in lymphoma patients include initial staging scans on a flat table, in order to assure similar position of future involved sites RT. Despite the extensive use of FDG with the above mentioned indications, neither evidence based guidelines, nor routine clinical practice could recommend follow up of lymphoma patients with FDG-PET. An exception could be made for ositive or

  15. FDG-PET/CT imaging in the management of HIV-associated multicentric Castleman's disease

    Energy Technology Data Exchange (ETDEWEB)

    Barker, Rob; Kazmi, Fahrad; Stebbing, Justin; Chinn, Roger [Imperial College School of Medicine, The Chelsea and Westminster Hospital, Department of Radiology, London (United Kingdom); Ngan, Sarah; Bower, Mark [Imperial College School of Medicine, The Chelsea and Westminster Hospital, Department of Oncology, London (United Kingdom); Nelson, Mark [Imperial College School of Medicine, The Chelsea and Westminster Hospital, Department of HIV Medicine, London (United Kingdom); O' Doherty, Michael [St. Thomas' Hospital, Clinical PET Centre, Guys and St. Thomas Hospital Trust, London (United Kingdom)

    2009-04-15

    To evaluate the role of FDG-PET/CT scanning in the management of HIV-associated multicentric Castleman's disease (MCD) a rare lymphoproliferative disorder associated with infection by human herpesvirus 8 (HHV8). Nine patients with histologically confirmed MCD underwent fused FDG-PET/CT scans at initial MCD diagnosis (n = 3), at MCD relapse (n = 4), or during remission (n = 2). All seven patients with active MCD had markedly elevated plasma HHV8 viral loads, but the patients in remission had no HHV8 viraemia. The three patients with newly diagnosed MCD were not on antiretroviral therapy at the time of imaging, but the other six were all on fully suppressive antiretroviral regimens. In the seven patients with active MCD (newly diagnosed or relapse) 33/91 lymph node groups (36%) included radiologically enlarged nodes on the CT scan, whilst 57/91 lymph node groups (63%) showed enhanced FDG uptake on the PET scan. In scans from patients in remission, there were no enlarged lymph nodes on the CT scan but 3 lymph nodes (11%) demonstrated enhanced FDG uptake. The median SUV recorded for the seven patients with active MCD was 4.8 (range 2.6-9.3) which was significantly higher than the median value of 2.5 recorded for the patients in remission (Mann-Whitney U test, p = 0.011). Despite the small number of patients, in HIV-positive individuals with active MCD, FDG-PET scans more frequently detected abnormal uptake than CT scans detected enlarged lymph nodes. FDG-PET scanning has a useful role in the management of HIV-associated MCD in selecting appropriate sites for biopsy, and in staging and monitoring these lymphoproliferations. (orig.)

  16. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  17. PET-CT in the evaluation of sarcomas of soft tissues

    International Nuclear Information System (INIS)

    Serna M, J.A.; Quiroz C, O.; Sanchez C, N.; Diaz V, G.

    2007-01-01

    18 F-FDG PET-CT is an image modality of great utility in the evaluation of primary or recurrent lesions of soft tissues. It is necessary to determine the cost-benefit of the different image modalities, although one waits that by means of a better diagnostic, statification and the determination of the grade of malignancy, the PET-CT nowadays can reduce the cost and the complications of the invasive diagnostic methods. (Author)

  18. Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Tian Xinhua; Liu Jianhua; Gong Tingting; Geng Lili; Sun Yong

    2011-01-01

    Objective: To investigate the clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease, and to evaluate the relationship of the image quality and radiation dose between prospective ECG-gated and retrospective ECG-gated cardiac CT angiography (CTA). Methods: Sixty patients who doubt congenital heart disease underwent cardiac CTA, and they were randomly divided into two groups. Thirty patients in group A underwent prospective ECG-gated cardiac CTA, and thirty patients in group B underwent retrospective ECG-gated cardiac CTA. Then the homogeneous enhancement of vascular structures, stair-step artifact, overall image quality and radiation dose were evaluated. Results: The homogeneous enhancement of vascular structures were 2.8±0.3 and 2.7±0.6, respectively, in two groups; and there was no statistical significance (P>0.05). The stair-step artifact were 3.0±0.9 and 3.1±0.9, respectively, in two groups; and there was also no statistical significance (P>0.05). The overall image quality were 3.0±0.8 and 3.1±0.9, respectively, in two group; and there was statistical significance (P>0.05). However, the effective dose were (5.24±0.52) mSv and (16.68±1.49) mSv, respectively, in two groups; and there was statistical significance (P<0.001). Conclusion: Compared with retrospective ECG-gated cardiac CTA, prospective ECG-gated cardiac CTA can reduce radiation dose about 68.6% , while maintaining the image quality which could be made diagnosis. (authors)

  19. T2 mapping of CT remodelling patterns in interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Buzan, Maria T.A. [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Eichinger, Monika; Heussel, Claus Peter [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Kreuter, Michael; Herth, Felix J. [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Thoraxklinik at Heidelberg University Hospital, Department of Pneumology, Center for Rare and Interstitial Lung Diseases, Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Warth, Arne [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); University Hospital Heidelberg, Institute for Pathology, Heidelberg (Germany); Pop, Carmen Monica [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Dinkel, Julien [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), Munich (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-11-15

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  20. T2 mapping of CT remodelling patterns in interstitial lung disease

    International Nuclear Information System (INIS)

    Buzan, Maria T.A.; Eichinger, Monika; Heussel, Claus Peter; Kreuter, Michael; Herth, Felix J.; Kauczor, Hans-Ulrich; Warth, Arne; Pop, Carmen Monica; Dinkel, Julien

    2015-01-01

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  1. PET for the evaluation of pleural thickening observed on CT

    NARCIS (Netherlands)

    Kramer, H; Pieterman, RM; Slebos, DJ; Timens, W; Vaalburg, W; Koeter, GH; Groen, HJM

    Early discrimination between benign and malignant pleural diseases is vital for the treatment and prognosis of a patient. Imaging is traditionally performed with CT or MRI, with an accuracy of 50%-75%. PET has proven to be superior as a diagnostic tool in several malignancies. In this prospective

  2. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  3. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  4. Dynamic computed tomography findings in cerebrovascular diseases

    International Nuclear Information System (INIS)

    Araki, Yutaka; Tomoda, Kaname; Kariya, Mitsumasa; Mori, Shigeru; Mitomo, Masanori.

    1988-01-01

    Dynamic CT was performed with 41 patients with the clinically diagnosed cerebrovascular diseases. A visual evaluation based on the dynamic CT images classified six patterns of brain parenchymal enhancement, especially four patterns of which could only be detected by dynamic CT technique. Dynamic CT was proved of great value in detecting regional cerebral tissue filled by collaterals in retrograde fashion because of the occlusion of main arteries, namely brain tissue perfusion of internal carotid occlusion disease and moyamoya disease was best understood by dynamic CT with adequate resolution. (author)

  5. Multicenter Comparison of Contrast-Enhanced FDG PET/CT and 64-Slice Multi-Detector-Row CT for Initial Staging and Response Evaluation at the End of Treatment in Patients With Lymphoma.

    Science.gov (United States)

    Gómez León, Nieves; Delgado-Bolton, Roberto C; Del Campo Del Val, Lourdes; Cabezas, Beatriz; Arranz, Reyes; García, Marta; Cannata, Jimena; González Ortega, Saturnino; Pérez Sáez, Mª Ángeles; López-Botet, Begoña; Rodríguez-Vigil, Beatriz; Mateo, Marta; Colletti, Patrick M; Rubello, Domenico; Carreras, José L

    2017-08-01

    To compare staging correctness between contrast-enhanced FDG PET/ceCT and 64-slice multi-detector-row CT (ceCT64) for initial staging and response evaluation at the end of treatment (EOT) in patients with Hodgkin lymphoma, diffuse large B cell lymphoma (DLBCL), and follicular lymphoma. This prospective study compared initial staging and response evaluation at EOT. One hundred eighty-one patients were randomly assigned to either ceCT64 or FDG PET/ceCT. A nuclear medicine physician and a radiologist read FDG PET/ceCT scans independently and achieved post hoc consensus, whereas another independent radiologist interpreted ceCT64 separately. The reference standard included all clinical information, all tests, and follow-up. Ethics committees of the participating centers approved the study, and all participants provided written consent. Ninety-one patients were randomized to ceCT64 and 90 to FDG PET/ceCT; 72 had Hodgkin lymphoma, 72 had DLBCL, and 37 had follicular lymphoma. There was excellent correlation between the reference standard and initial staging for both FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84), although evaluation of the response at EOT was excellent only for FDG PET/ceCT (κ = 0.91). Our study demonstrated satisfactory agreement between FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84) in initial staging compared with the reference standard (P = 0.16). Response evaluation at EOT with FDG PET/ceCT (κ = 0.91) was superior compared with ceCT64 (κ = 0.307) (P < 0.001).

  6. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    International Nuclear Information System (INIS)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi; Morikage, Noriyasu; Sano, Yuichi; Suga, Kazuyoshi

    2013-01-01

    Background: Dual-energy perfusion CT (DE p CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE p CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE p CT using a 64-slice dual-source CT. DE p CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V 120 ), 1-15 HU (V 15 ), 1-10 HU (V 10 ), and 1-5 HU (V 5 ). Each relative ratio per V 120 was expressed as the %V 15 , %V 10 , and %V 5 . Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V 15 , V 10 , V 5 , %V 15 , %V 10 , and %V 5 were also significantly higher than those without IPC (P = 0.001). %V 5 had a better correlation with D-dimer (r = 0.30, P p CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE

  7. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  8. The role of pneumothorax CT for the evaluation of aortic invasion by lung cancer

    International Nuclear Information System (INIS)

    Yokoi, Kohei; Mori, Kiyoshi; Miyazawa, Naoto; Magota, Seizo; Honda, Kazuyoshi; Sasagawa, Michizo

    1987-01-01

    To improve the accuracy of T3 diagnosis in lung cancer, Pneumothorax CT was carried out in four patients having diagnosis of plain CT and enhanced CT. Both plain and enhanced CT demonstrated obliteration of low density zone between tumor and the aorta in all cases. In three of four cases, Pneumothorax CT, however, demonstrated free air space where tumor was evaluated to be invaded. Remaining one presented the loss of such free air space even by Pneumothorax CT and was made the diagnosis of aortic invasion, which was confirmed by surgicopathological finding. Pneumothorax CT is useful for the diagnosis of ruling out tumor invasion to the aorta. (author)

  9. What is the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after CT?

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Kwanseop [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)], E-mail: kwanseop@hallym.or.kr; Kim, Min-Jeong; Yoon, Hoi Soo; Jeon, Eui Yong; Koh, Sung Hye [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Min, Kwangseon [Department of Pathology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Choi, Dongil [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (Korea, Republic of)

    2010-04-15

    The objective of our study was to estimate the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after abdominoplevic CT. A total of 104 patients initially underwent abdominopelvic CT before appendix US due to acute abdominal pain. All CT examinations were evaluated retrospectively for the presence of acute appendicitis. The findings of appendix on CT were classified into five categories (definite appendicitis, probably appendicitis, equivocal CT findings for diagnosis of appendicitis, probably not appendicitis, and normal looking appendix). Appendix US images and their radiologic reports were also evaluated retrospectively. Then, CT and US findings were correlated with clinical or pathologic diagnosis. Three all patients with definite appendicitis initially on CT again showed US findings of appendicitis. In the 32 patients of probably appendicitis on CT, US showed normal looking appendix in seven patients (21.8%, 7 of 32) who improved with medical treatment and discharged. In the 16 patients of equivocal CT findings for diagnosis of appendicitis, US showed appendicitis in seven patients (43.8%, 7 of 16) and normal looking appendix in nine patients. In the 12 patients of probably not appendicitis on CT, US showed acute appendicitis in two patients (16.7%, 2 of 12). In the 41 patients of normal looking appendix on CT, US showed acute appendicitis in five patients (12.2%, 5 of 41). US reevaluation enables us to avoid misdiagnosis of appendicitis on CT and improve diagnostic accuracy of acute appendicitis.

  10. Diagnosis of non-osseous spinal metastatic disease: the role of PET/CT and PET/MRI.

    Science.gov (United States)

    Batouli, Ali; Braun, John; Singh, Kamal; Gholamrezanezhad, Ali; Casagranda, Bethany U; Alavi, Abass

    2018-06-01

    The spine is the third most common site for distant metastasis in cancer patients with approximately 70% of patients with metastatic cancer having spinal involvement. Positron emission tomography (PET), combined with computed tomography (CT) or magnetic resonance imaging (MRI), has been deeply integrated in modern clinical oncology as a pivotal component of the diagnostic work-up of patients with cancer. PET is able to diagnose several neoplastic processes before any detectable morphological changes can be identified by anatomic imaging modalities alone. In this review, we discuss the role of PET/CT and PET/MRI in the diagnostic management of non-osseous metastatic disease of the spinal canal. While sometimes subtle, recognizing such disease on FDG PET/CT and PET/MRI imaging done routinely in cancer patients can guide treatment strategies to potentially prevent irreversible neurological damage.

  11. Two- and three-dimensional CT evaluation of sacral and pelvic anomalies

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Magid, D.

    1988-01-01

    Pelvic anomalies are difficult to evaluate with standard techniques. Detailed knowledge of the existing pelvic structures and musculature is essential for successful repair. The authors evaluated 12 patients with complex malformations of the pelvis using two- and three-dimensional imaging. The anomalies included bladder exstrophy (n = 4), cloacal exstrophy (n = 1), duplicated and absent sacrum (n = 3), myelomeningoceles (n = 2), and diastrophic dwarfism (n = 2). The two-dimensional images consisted of sequential coronal and sagittal reconstructions that could be reviewed dynamically on screen. Three-dimensional images were generated on the Pixar imaging computer with use of volumetric rendering. Two- and three-dimensional CT proved complementary in the evaluation of pelvic anomalies, providing optimal information from transaxial CT data

  12. Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyun; Chang, Yun Woo; Hwang, Jung Hwa; Kim, Hyung Hwan; Lee, Eun Hye; Yang, Seung Boo

    2013-01-01

    To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy.

  13. CT evaluation of hepatocellular carcinomas supplied by right inferior phrenic arteries

    International Nuclear Information System (INIS)

    Wen Ming; Zhu Mingxia; Huang Yonghuo

    2002-01-01

    Objective: To evaluate the CT appearance of the hepatocellular carcinomas (HCC) supplied by the right inferior phrenic arteries (RIPA). Methods: A total of 195 consecutive cases of HCCs examined with helical CT and arteriography were studied. 15 proven HCCs cases were supplied by the RIPA. On arterial-phase CT images, the size of the RIPA, the left inferior phrenic arteries, and HCCs were measured, and the origin of RIPA and the location of HCCs were recorded. The CT findings in these 15 cases were correlated with arterio-graphic images. Results: CT showed RIPA on the right diaphragmatic crus as high attenuation in all patients. The origin of RIPA was demonstrated in 11 cases. The diameter of the RIPA (3.1 +- 1.1) mm was larger than that of the left inferior phrenic artery (1.3 +- 0.4) mm (P < 0.05). Conclusion: On CT images, if the RIPA asymmetrically dilates, and its diameter is larger than 2.5 mm, it is suggested that the HCC is supplied by the RIPA

  14. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.

    Science.gov (United States)

    Matenine, Dmitri; Mascolo-Fortin, Julia; Goussard, Yves; Després, Philippe

    2015-11-01

    The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of

  15. Significance of computed tomography for diagnosis of heart diseases

    International Nuclear Information System (INIS)

    Senda, Kohei; Sakuma, Sadayuki

    1983-01-01

    Computed tomography (CT) with a 2 sec scanner was carried out on 105 cases with various heart disease in order to detect CT findings in each heart disease. Significance of CT as a imaging study was evaluated in comparison with scintigraphic, echographic and roentgenographic studies. CT with contrast enhancement in moderate inspiration was able to demonstrate accurately organic changes of intra-and extracardiac structure. Comparing with other imaging studies, CT was superior in detection of calcified or intracardiac mass lesion in spite of low value in evaluating cardiac function or dynamics. (author)

  16. CT pulmonary densitovolumetry in patients with acromegaly: a comparison between active disease and controlled disease

    Science.gov (United States)

    Camilo, Gustavo B; Carvalho, Alysson R S; Machado, Dequitier C; Mogami, Roberto; Melo, Pedro L

    2015-01-01

    Objective: Our purpose was to compare the findings of CT pulmonary densitovolumetry and pulmonary function in patients with active acromegaly and controlled acromegaly and, secondarily, to correlate these findings. Methods: 11 patients with active acromegaly, 18 patients with controlled acromegaly and 17 control subjects, all non-smokers, underwent quantification of lung volume using multidetector CT (Q-MDCT) and pulmonary function tests. Results: Patients with active acromegaly had larger total lung mass (TLM) values than the controls and larger amounts of non-aerated compartments than the other two groups. Patients with active acromegaly also had larger amounts of poorly aerated compartments than the other two groups, a difference that was observed in both total lung volume (TLV) and TLM. TLV as measured by inspiratory Q-MDCT correlated significantly with total lung capacity, whereas TLV measured using expiratory Q-MDCT correlated significantly with functional residual capacity. Conclusion: Patients with active acromegaly have more lung mass and larger amounts of non-aerated and poorly aerated compartments. There is a relationship between the findings of CT pulmonary densitovolumetry and pulmonary function test parameters. Advances in knowledge: Although the nature of our results demands further investigation, our data suggest that both CT pulmonary densitovolumetry and pulmonary function tests can be used as useful tools for patients with acromegaly by assisting in the prediction of disease activity. PMID:26246281

  17. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  18. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  19. Evaluation of the low dose cardiac CT imaging using ASIR technique

    Science.gov (United States)

    Fan, Jiahua; Hsieh, Jiang; Deubig, Amy; Sainath, Paavana; Crandall, Peter

    2010-04-01

    Today Cardiac imaging is one of the key driving forces for the research and development activities of Computed Tomography (CT) imaging. It requires high spatial and temporal resolution and is often associated with high radiation dose. The newly introduced ASIR technique presents an efficient method that offers the dose reduction benefits while maintaining image quality and providing fast reconstruction speed. This paper discusses the study of image quality of the ASIR technique for Cardiac CT imaging. Phantoms as well as clinical data have been evaluated to demonstrate the effectiveness of ASIR technique for Cardiac CT applications.

  20. CT versus FDG-PET/CT response evaluation in patients with metastatic colorectal cancer treated with irinotecan and cetuximab

    DEFF Research Database (Denmark)

    Skougaard, Kristin; Johannesen, Helle Hjorth; Nielsen, Dorte

    2014-01-01

    included in a phase II trial and treated with cetuximab and irinotecan every second week. They underwent FDG-PET/CT examination at baseline and after every fourth treatment cycle. Response evaluation was performed prospectively according to Response Evaluation Criteria in Solid Tumors (RECIST 1...

  1. Labyrinthitis ossificans in a child with sickle cell disease: CT and MRI findings

    International Nuclear Information System (INIS)

    Liu, Benjamin P.; Saito, Naoko; Wang, Jimmy J.; Mian, Asim Z.; Sakai, Osamu

    2009-01-01

    The association between sensorineural hearing loss and sickle cell disease has been described, and labyrinthine hemorrhage has been reported with sickle cell disease. We report the CT and MRI findings of labyrinthitis ossificans in a child with sickle cell disease who presented with sensorineural hearing loss. Labyrinthitis ossificans is associated with an infectious, inflammatory, or destructive insult to the membranous labyrinth; however, it has not been specifically described with sickle cell disease. Recognition of this condition is important because it affects both management and prognosis of this disease. (orig.)

  2. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  3. An immunoglobulin G-4 related sclerosing disease of the small bowel: CT and small bowel series findings

    International Nuclear Information System (INIS)

    Ko, Young Hwan; Hwang, Dae Hyun; Min, Seon Jeong; Woo, Ji Young; Kim, Jeong Won; Hong, Hye Sook; Yang, Ik; Lee, Yul

    2013-01-01

    Immunoglobulin G4 (IgG4)-related sclerosing disease is rare and is known to involve various organs. We present a case of histologically proven IgG4-related sclerosing disease of the small bowel with imaging findings on computed tomography (CT) and small bowel series. CT showed irregular wall thickening, loss of mural stratification and aneurysmal dilatation of the distal ileum. Small bowel series showed aneurysmal dilatations, interloop adhesion with traction and abrupt angulation.

  4. Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.

    Science.gov (United States)

    Nakajima, Reiko; Abe, Koichiro; Kondo, Tsunenori; Tanabe, Kazunari; Sakai, Shuji

    2016-06-01

    We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB phases, and compared the accumulation values with regard to histological type (clear cell carcinoma [CCC] vs. non-clear cell carcinoma [N-CCC]), the TNM stage (high stage [3-4] vs. low stage [1-2]), the Fuhrman grade (high grade [3-4] vs. low grade [1-2]) and presence versus absence of venous (V) and lymphatic (Ly) invasion. In the ED phase, visual evaluation revealed no significant differences in FDG accumulation in terms of each item. However, the maximum standardized uptake value and tumour-to-normal tissue ratios were significantly higher in the CCCs compared to the N-CCCs (p PET/CT is a useful tool for the evaluation of RCCs. • ED and WB FDG-PET/ CT helps to assess patients with RCC • ED FDG-PET/CT enabled differentiation between CCC and N-CCC • FDG accumulation in the WB phase reflects tumour aggressiveness • Management of RCC is improved by ED and WB FDG-PET/CT.

  5. Prognostic Value of FDG-PET, Based on the Revised Response Criteria, in Patients with Malignant Lymphoma: A Comparison with CT/MRI Evaluations, Based on the International Working Group/ Cotswolds Meeting Criteria

    Directory of Open Access Journals (Sweden)

    Kayako Isohashi

    2015-07-01

    Full Text Available Objective(s: Post-treatment evaluations by CT/MRI (based on the International Working Group/ Cotswolds meeting guidelines and PET (based on Revised Response Criteria, were examined in terms of progression-free survival (PFS in patients with malignant lymphoma (ML. Methods: 79 patients, undergoing CT/MRI for the examination of suspected lesions and whole-body PET/CT before and after therapy, were included in the study during April 2007-January 2013. The relationship between post-treatment evaluations (CT/MRI and PET and PFS during the follow-up period was examined, using Kaplan-Meier survival analysis. The patients were grouped according to the histological type into Hodgkin’s lymphoma (HL, diffuse large B-cell lymphoma (DLBCL, and other histological types. The association between post-treatment evaluations (PET or PET combined with CT/ MRI and PFS was examined separately. Moreover, the relationship between disease recurrence and serum soluble interleukin-2 receptor, lactic dehydrogenase, and C-reactive protein levels was evaluated before and after the treatment. Results: Patients with incomplete remission on both CT/MRI and PET had a significantly shorter PFS, compared to patients with complete remission on both CT/MRI and PET and those exhibiting incomplete remission on CT/MRI and complete remission on PET (P

  6. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  7. Evaluation of the role of 18FDG-PET/CT in radiotherapy target definition in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Newbold, Katie L; Partridge, Mike; Cook, Gary; Sharma, Bhupinder; Rhys-Evans, Peter; Harrington, Kevin J; Nutting, Christopher M [The Royal Marsden NHS Foundation Trust, Sutton, Surrey (United Kingdom)

    2008-08-15

    Background and purpose. As techniques for radiotherapy delivery have developed, increasingly accurate localisation of disease is demanded. Functional imaging, particularly PET and its fusion with anatomical modalities, such as PET/CT, promises to improve detection and characterisation of disease. This study evaluated the impact of 18FDG-PET/CT on radiotherapy target volume definition in head and neck cancer (HNC). Materials and methods. The PET/CT scans of patients with HNC were used in a radiotherapy planning (RTP) study. The gross tumour volume (GTV), clinical target volume (CTV) and planning target volume (PTV) were defined conventionally and compared to those defined using the PET/CT. Data were reported as the median value with 95% confidence intervals. Results. Eighteen patients were consented, 9 had known primary tumour site, 9 presented as unknown primary. In nine cases where the primary site was known, the combined primary and nodal GTV (GTVp+n) increased by a median of 6.1cm3 (2.6, 12.2) or 78% (18, 313), p=0.008 with CTV increasing by a median of 10.1cm3 (1.3, 30.6) or 4% (0, 13) p=0.012. In 9 cases of unknown primary the GTVp+n increased by a median 6.3cm3 (0.2, 15.7) or 61% (4, 210), p=0.012, with CTV increasing by a median 155.4cm3 (2.7, 281.7) or 95% (1, 137), p=0.008. Conclusion. 18FDG-PET revealed disease lying outside the conventional target volume, either extending a known area or highlighting a previously unknown area of disease, including the primary tumour in 5 cases. We recommend PET/CT in the RTP of all cases of unknown primary. In patients with a known primary, although the change in volume was statistically significant the clinical impact is less clear. 18FDG-PET can also show areas within the conventional target volume that are hypermetabolic which may be possible biological target volumes for dose escalation studies in the future

  8. Efficacy and Safety of the Biosimilar Infliximab CT-P13 Treatment in Inflammatory Bowel Diseases: A Prospective, Multicentre, Nationwide Cohort.

    Science.gov (United States)

    Gecse, Krisztina B; Lovász, Barbara D; Farkas, Klaudia; Banai, János; Bene, László; Gasztonyi, Beáta; Golovics, Petra Anna; Kristóf, Tünde; Lakatos, László; Csontos, Ágnes Anna; Juhász, Márk; Nagy, Ferenc; Palatka, Károly; Papp, Mária; Patai, Árpád; Lakner, Lilla; Salamon, Ágnes; Szamosi, Tamás; Szepes, Zoltán; Tóth, Gábor T; Vincze, Áron; Szalay, Balázs; Molnár, Tamás; Lakatos, Péter L

    2016-02-01

    Biosimilar infliximab CT-P13 is approved for all indications of the originator product in Europe. Prospective data on its efficacy, safety, and immunogenicity in inflammatory bowel diseases are lacking. A prospective, nationwide, multicentre, observational cohort was designed to examine the efficacy, safety, and immunogenicity of CT-P13 infliximab biosimilar in the induction treatment of Crohn's disease [CD] and ulcerative colitis [UC]. Demographic data were collected and a harmonised monitoring strategy was applied. Early clinical remission, response, and early biochemical response were evaluated at Week 14, steroid-free clinical remission was evaluated at Week 30. Therapeutic drug level was monitored using a conventional enzyme-linked immunosorbent assay. In all, 210 consecutive inflammatory bowel disease [126 CD and 84 UC] patients were included in the present cohort. At Week 14, 81.4% of CD and 77.6% of UC patients showed clinical response and 53.6% of CD and 58.6% of UC patients were in clinical remission. Clinical remission rates at Week 14 were significantly higher in CD and UC patients who were infliximab naïve, compared with those with previous exposure to the originator compound [p < 0.05]. Until Week 30, adverse events were experienced in 17.1% of all patients. Infusion reactions and infectious adverse events occurred in 6.6% and 5.7% of all patients, respectively. This prospective multicentre cohort shows that CT-P13 is safe and effective in the induction of clinical remission and response in both CD and UC. Patients with previous infliximab exposure exhibited decreased response rates and were more likely to develop allergic reactions. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  9. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  10. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  11. RADIOLOGICAL EVALUATION OF OBSTRUCTIVE JAUNDICE BY ULTRASOUND AND CT

    Directory of Open Access Journals (Sweden)

    Padmalatha

    2015-10-01

    Full Text Available INTRODUCTION: The goals of any radiologic procedure in obstructive Jaundice are to confirm the presence of bile duct obstruction, its location, its extent & the probable cause. It should also attempt to obtain a map of the biliary tree that will help the surgeon to det ermine the best approach to each individual case. OBJECTIVES: 1. To evaluate the role of Ultrasound and CT in patients presenting with clinical features of obstructive jaundice. 2. To evaluate the causes of obstructive jaundice by Ultrasound and CT. PATIENTS AND METHODS: The study was carried with 45 patients from January 2006 to September 2007 who were attending the surgical and Gastroenterology Departments, Govt. General Hospital, Kurnool, which is an attached hospital to Kurnool Medical College, Kurnool. O BSERVATIONS AND RESULTS: In our study, there is female predominance with male: female ratio 1: 1.6.Majority of patients are in age group of 41 - 50 years. Jaundice was the commonest presentation in all patients followed by pruritis in 72% and pain abdomen in 67% of patients. Ultrasound identified the benign cause of biliary obstruction in 79.1% cases and the malignant cause in 61.9% cases. CT identified the benign cause of biliary obstruction in 91.6% of patients and the malignant cause in 80.9% cases.

  12. The central nervous system manifestation and CT findings of Fabry's disease

    International Nuclear Information System (INIS)

    Toyonaga, Kazutaka; Nishihira, Takeo

    1983-01-01

    A case of Fabry's disease with central nervous system dysfunction is reported. This 27-year-old man had recurrent episodes of pains in the extremities when he was a child. Spontaneous clinical remission occured around puberty. He had been well until age 22 when he experienced transient weakness of the left arm. The following year he developed transient blindness of the right eye. Then, he developed weakness in the extremities, dysphagia, dysarthria, and was brought to the hospital in unconscious state. Several members of his family are affected with the same disease presenting leg pains, kidney disease and angiokeratoma. Physical examination disclosed an optic atrophy, pseudobulbar palsy with spastic weakness in the all extremities and multiple angiokeratoma in the flank, buttocks and thighs. Abnormal laboratory findings included leukocytosis, increased ESR and strongly positive CRP. Biopsy of the skin disclosed dilated capilaries with numerous vacuoles in the cytoplasm of the epithelial cells. Thin-layer chromatography of the urine sediment showed a marked increase in ceramide trihexoside. Leukocyte alphagalactosidase level was abnormally low. CT scan showed diffuse cerebral atrophy and multiple low density areas in the thalamus, ventral pons and centrum semiovale. The CT findings and possible mechanism of the response to predonisolone were also discussed. (author)

  13. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  14. Diagnosing extracranial atherosclerotic diseases with spiral CT

    International Nuclear Information System (INIS)

    Moran, C.J.; Vannier, M.W.; Erickson, K.K.; Broderick, D.F.; Kido, D.K.; Yoffie, R.L.

    1991-01-01

    This paper reports that this discovery study was performed to determine whether extracranial carotid artery plaques could be diagnosed with a new CT technique (spiral CT) that allows nondistorted three-dimensional (3D) reconstructions in the z axis. Twenty carotid arteries were examined with spiral CT in normal volunteers and in patients suspected of having atherosclerotic plaques in the extracranial carotid arteries. The Somatom Plus CT table was advanced at a constant rate, the x-ray tube was continuously rotated, and 3D data were continuously acquired. Sixty milliliters of nonionic contrast medium was injected intravenously previous to and during the acquisition of data. The carotid bifurcations were identified in all patients. Planar images, similar to conventional intraarterial angiograms, were routinely produced from the volumetric CT data

  15. The role of 11C-choline positron emission tomography- computed tomography and videomediastinoscopy in the evaluation of diseases of middle mediastinum

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Middle mediastinal masses comprise a wide variety of tumors but may also reflect lymphadenopathy, and thus remain an interesting diagnostic challenge. We performed positron emission tomography (PET) of mediastinal masses in order to evaluate the ability of PET to predict the malignancy of these tumors. We compared histologic findings, videomediastinoscopy, computed tomography (CT), and PET-CT in patients with mediastinal disease. Methods Thirty-two patients were evaluated with CT, PET-CT and videomediastionoscopy, and all studies were performed within four weeks in each patient. 11C-choline as a PET tracer was used to visualize masses. PET data were evaluated using the standardized uptake value (SUV) and were compared with pathologic data.Results There were 13 men and 19 women aged from 21 to 74 (mean 45.2) years. Among the patients with mediastinal diseases, sarcoidosis was diagnosed in 12 patients, tuberculosis in 5 patients, lymphoma in 5 patients, and noncaseating granulomata without classical "sarcoid" finding in 3 patients. N2 or N3 nodal metastasis was revealed in 6 of 7 patients who had non-small cell lung cancer or suspected lung cancer, and one was negative (the pathological diagnosis was reactive hyperplasia). The accuracies for correctly diagnosing mediastinal masses for CT, PET-CT and videomediastinoscopy were 38% (12/32), 63% (20/32), and 91% (29/32) respectively. The diagnostic accuracy of videomediastinoscopy was superior to that of PET-CT (χ2=11.130,P<0.001). The SUVs were similar among these diseases. On the other hand, if the diagnostic classification was benign vs malignancy, the accuracies for CT, PET-CT and videomediastinoscopy were 53% (17/32), 75% (24/32), 100% (32/32) respectively. The diagnostic accuracy of videomediastinoscopy was superior to that of PET-CT (χ2=22.042, P<0.001). The SUV of malignant lesions (6.9, 3.2-9.8; n=11) appeared to be higher than that of benign lesions (4.9, 2.9-8.3; n=21), however, this difference

  16. Usefulness of {sup 18}F-FDG-PET/CT in Evaluating a Brainstem Glioma in an Adult Patient with Neurofibromatosis Type 1

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Muoio, Barbara; Del Ciello, Annemilia [Univ. of the Sacred, Rome (Italy); Bertagna, Francesco [Univ. of Brescia, Brescia (Italy)

    2013-09-15

    We describe a case of a brainstem glioma (BSG) occurred in an adult patient with neurofibromatosis type 1 (NF1) and evaluated by Flourine-18-Fluorodeoxyglucose-positron emission tomography/computed tomography ({sup 18}F-FDG-PET/CT). A 32-year-old male patient with NF1 underwent brain magnetic resonance imaging (MRI) for the onset of diplopia, facial paresis and cerebellar signs and symptoms. MRI showed a brainstem lesion compatible with BSG. Biopsy was not performed. {sup 18}F-FDG-PET/CT demonstrated intense {sup 18}F-FDG uptake in the brainstem lesion, suggesting an aggressive neoplasm. The patient was referred to radiotherapy but he developed rapid disease progression. In this case, {sup 18}F-FDG-PET/CT provided useful information about this rare NF1-associated tumor. Subsequently, the patient was referred to radiotherapy, but he developed rapid disease progression and died 3 months later. NF-1 is an autosomal dominant disorder characterized by multiple cafe-au-lait spots, axillary and inguinal freckling, multiple cutaneous neurofibromas, and iris Lisch nodules. NF-1 is also characterized by low-grade tumors of the central and peripheral nervous system. There is also an increased risk of developing malignant tumors such as malignant peripheral nerve sheath tumors or central nervous system high-grade gliomas. NF1-associated BSGs are less common than NF1-associated optic gliomas (OGs) and seem to represent a particular entity which tend, as a whole, to have a more favorable prognosis and a more indolent course than BSGs in patients without NF1; nevertheless, some NF1-associted BSG may rapidly progress. {sup 18}F-FDG-PET/CT has demonstrated to provide useful information to the surveillance of OGs in children with NF1, particularly to identify progressive, symptomatic tumors. To the best of our knowledge, there are no data about the usefulness of {sup 18}F-FDG-PET/CT in adult patients with NF1-associated BSG. In our case, {sup 18}F-FDG-PET/CT has been useful in

  17. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    Science.gov (United States)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the

  18. Two cases of cervical disc disease with intramedullary pathological changes, which are responsible for their neurological syndromes, on delayed CT myelography

    International Nuclear Information System (INIS)

    Isu, Toyohiko; Iwasaki, Yoshinobu; Abe, Hiroshi; Tashiro, Kunio; Murai, Hiroshi; Miyasaka, Kazuo

    1987-01-01

    We report two cases of cervical disc disease with myelopathy classified as of motor system syndrome type showing small contrast accumulation within the spinal cord on delayed CT myelography. In our two cases, high density spots on delayed CT myelography were bilaterally localized within the spinal cord, and believed represent pathological changes of the spinal cord, such as collection of microcavities or cystic necrosis. In case 1, the high density areas seemed to be localized in the anterior horn and corticospinal tract, and in case 2, they seemed to be localized in the corticospinal tract. The patient in case 1 produced signs and symptoms resembling motor neurone disease and lesion could not be differentiated from the latter. Delayed CT myelography showed that the cause of the upper limb amyotrophy was attributed to an anterior horn disorder and that of pyramidal tract sign to a corticospinal tract disorder. Therefore, we could differentiate the lesion from motor neurone disease on delayed CT myelography in case 1. In conclusion, we emphasize that delayed CT myelography can demonstrate the intramedullary pathological changes in the cervical disc disease and is useful in distinguishing between cervical disc disease simulating motor neurone disease and the latter. (author)

  19. Dysplastic gangliocytoma of the cerebellum (Lhermitte-Duclos disease). Case report with CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Uki, Jiro; Kanda, Shinji; Asakura, Ken; Takeda, Fumikazu

    1985-08-01

    A case of dysplastic gangliocytoma of the cerebellum, or Lhermitte-Duclos disease, is reported along with its CT findings, and the cases so far reported in the literature are reviewed. This is the 50th case report since the first description in 1920. This 61-year-old female had suffered from right hemifacial spasms for more than 20 years and from bilateral tinnitus with auditory disturbances for two years. Four years before admission, she underwent gastric resection and cancer chemotherapy for gastric cancer. Plain craniograms showed a thinned and ballooned occipital squama on the right side. Vertebral angiograms revealed a large tumor stain, with early venous filling, in the right posterior fossa. A CT scan showed a large, low-density mass, with small calcified areas in it, in the right posterior fossa. A postcontrast CT scan revealed no contrast enhancement, except for dilated vascular enhancement, within the tumor. No hydrocephalus was observed. Metrizamide CT cisternography revealed a huge intraaxial mass compressing the brain stem. (J.P.N.).

  20. Gynecological applications of helical CT using SmartPrep

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Akira; Kakizaki, Dai; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1999-11-01

    SmartPrep is software program for scanning a given region of interest (ROI) at optimal contrast density. An operator can arbitrarily define ROI and preset the CT value at which scanning should be started. After the injection of a contrast medium, system conducts continuous monitoring of the ROI and the operator starts helical scanning of the planned region when the present CT value has been reached. In comparison with conventional helical CT that requires a period of time from the beginning of contrast medium injection to the beginning of scanning, SmartPrep minimizes personal error and better depicts the artery-predominant phase under optimal conditions. In this study we examine the usefulness of contrast-enhanced helical CT using SmartPrep in the evaluation of gynecological disease. When the contrast medium was injected into the dorsal vein of the hand at a rate of 3 ml/sec, strong staining of pelvic arteries was observed in the CT images started at 17 to 23 sec after injection. The early-phase helical CT obtained under these conditions provided good depiction of lesions in cases of placenta accreta and invasive mole, as well as clear demonstration of tumor angiogenesis and evaluation of laterality in cases of cervical cancer. Comparison of the early and delayed phase also facilitated easier evaluation of lymph nodes than conventional comparison of simple and contrast-enhanced CT. The results thus suggest the usefulness of contrast-enhanced helical CT using SmartPrep in gynecology. (author)