WorldWideScience

Sample records for directional firing properties

  1. 75 FR 221 - Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire...

    Science.gov (United States)

    2010-01-05

    ... Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire Extinguishers as Installed... specification, have been supplied to the aviation industry for use in fire extinguishing equipment. * * * * * * * * * * * This Halon 1211 has subsequently been used to fill certain FFE [Fire Fighting Enterprises] portable...

  2. Direct estimation of diffuse gaseous emissions from coal fires: current methods and future directions

    Science.gov (United States)

    Engle, Mark A.; Olea, Ricardo A.; O'Keefe, Jennifer M. K.; Hower, James C.; Geboy, Nicholas J.

    2013-01-01

    Coal fires occur in nature spontaneously, contribute to increases in greenhouse gases, and emit atmospheric toxicants. Increasing interest in quantifying coal fire emissions has resulted in the adaptation and development of specialized approaches and adoption of numerical modeling techniques. Overview of these methods for direct estimation of diffuse gas emissions from coal fires is presented in this paper. Here we take advantage of stochastic Gaussian simulation to interpolate CO2 fluxes measured using a dynamic closed chamber at the Ruth Mullins coal fire in Perry County, Kentucky. This approach allows for preparing a map of diffuse gas emissions, one of the two primary ways that gases emanate from coal fires, and establishing the reliability of the study both locally and for the entire fire. Future research directions include continuous and automated sampling to improve quantification of gaseous coal fire emissions.

  3. Physical, mechanical, and fire properties of oriented strandboard with fire retardant treated veneers

    Science.gov (United States)

    Nadir Ayrilmis; Zeki Candan; Robert White

    2007-01-01

    This study evaluated physical, mechanical and fire properties of oriented strand boards (OSB) covered with fire retardant treated veneers. The beech (Fagus orientalis Lipsky) veneers were treated with either monoammonium phosphate, diammonium phosphate, lime water or a borax/boric acid (1 : 1 by weight) mixture. Physical and mechanical properties of the specimens were...

  4. Effects of prescribed fires on soil properties: A review.

    Science.gov (United States)

    Alcañiz, M; Outeiro, L; Francos, M; Úbeda, X

    2018-02-01

    Soils constitute one of the most valuable resources on earth, especially because soil is renewable on human time scales. During the 20th century, a period marked by a widespread rural exodus and land abandonment, fire suppression policies were adopted facilitating the accumulation of fuel in forested areas, exacerbating the effects of wildfires, leading to severe degradation of soils. Prescribed fires emerged as an option for protecting forests and their soils from wildfires through the reduction of fuels levels. However such fires can serve other objectives, including stimulating the regeneration of a particular plant species, maintaining biological diversity or as a tool for recovering grasslands in encroached lands. This paper reviews studies examining the short- and long- term impacts of prescribed fires on the physical, chemical and biological soil properties; in so doing, it provides a summary of the benefits and drawbacks of this technique, to help determine if prescribed fires can be useful for managing the landscape. From the study conducted, we can affirm that prescribed fires affects soil properties but differ greatly depending on soil initial characteristics, vegetation or type of fire. Also, it is possible to see that soil's physical and biological properties are more strongly affected by prescribed fires than are its chemical properties. Finally, we conclude that prescribed fires clearly constitute a disturbance on the environment (positive, neutral or negative depending on the soil property studied), but most of the studies reviewed report a good recovery and their effects could be less pronounced than those of wildfires because of the limited soil heating and lower fire intensity and severity. Copyright © 2017. Published by Elsevier B.V.

  5. Deterioration of mechanical properties of high strength structural steel S460N under transient state fire condition

    International Nuclear Information System (INIS)

    Qiang, Xuhong; Bijlaard, Frans S.K.; Kolstein, Henk

    2012-01-01

    Highlights: ► Mechanical properties of S460N under transient state fire condition are obtained. ► Elevated-temperature mechanical properties of steels are dependent on steel grades. ► No design standard is applicable to HSS S460N under transient state fire condition. ► Specific statements on various HSS in fire should be proposed in design standards. ► Research results offer accurate material property for structural design engineers. -- Abstract: 911 World Trade Centre Tragedy put fire safety of constructional steel structures into question. Since then, more and more research attention has been paid to the elevated-temperature mechanical properties of structural steels, which is a critical basis of evaluating the fire performance of steel structures. In the literature the available mechanical properties of structural steels under fire conditions were mainly obtained from steady state test method, as steady state test method is easier to perform than transient state test method and offers stress–strain curves directly. However, the transient state fire condition is considered to be more realistic to represent the real condition when constructions are exposed to fire. In order to reveal the deterioration of mechanical properties of the commonly used high strength structural steel S460N under transient state fire condition, tensile tests were conducted under various constant stress levels up to 800 MPa. The reduction factors of elastic modulus, yield and ultimate strengths of S460N under transient state fire condition were obtained and compared with current leading design standards and available literature. The application of such accurate elevated-temperature mechanical properties reduction factors of S460N can ensure a safe fire-resistance design and evaluation of steel structures with high strength steel S460N under transient state fire condition. This experimental study also supports other relative research on fire performance of steel structures with

  6. Direct carbon emissions from Canadian forest fires, 1959-1999

    International Nuclear Information System (INIS)

    Amiro, B. D.; Todd, J. B.; Flannigan, M. D.; Hirsch, K. G.; Wotton, B. M.; Logan, K. A.; Stocks, B. J.; Mason, J. A.; Martell, D. L.

    2001-01-01

    Fire is recognised as driving most of the boreal forest carbon balance in North America, therefore fires not only impact on carbon sequestration by forests, but emit greenhouse gases that have the potential to affect the environment. In this paper direct emissions of carbon from Canadian forest fires were estimated for all of Canada and for each ecozone for the period 1959 to 1999. Estimates were based on large fires ; fuel consumption for each fire was calculated using the Canadian Forest Fire Behaviour Prediction System. There were about 11,400 forest fires, averaging 2 x 10 6 hectare per year during this period. Boreal and taiga areas experienced the greatest area burned, releasing most of the carbon. The mean area-weighted fuel consumption for all fires was 2.6 kg of dry fuel per m 2 (1.3 kg carbon per m 2 ) varying from 1.8 kg to 3.9 kg per m 2 among ecozones. The mean annual direct carbon emission was estimated at 27 + or - 6 Tg carbon per year, or about 18 per cent of current carbon dioxide emissions from the Canadian energy sector, on average. This excludes post-fire effects, which cause an additional loss of carbon; changes to the forest also affect the strength of the forest carbon sink. Fire emissions have shown an increase over the past two decades and are likely to remain high due to anticipated changes in fire weather resulting from climate warming. 48 refs., 3 tabs., 6 figs

  7. Effects of fire retardants on physical, mechanical, and fire properties of flat-pressed WPCs

    Science.gov (United States)

    Nadir Ayrilmis; Jan T. Benthien; Heiko Thoemen; Robert H. White

    2012-01-01

    Physical, mechanical, and fire properties of the flat-pressed wood plastic composites (WPCs) incorporated with various fire retardants (10% by weight) at different levels of wood flour (WF) content, 40, 50, or 60 wt%, were investigated. The WPC panels were made from dry-blended WF, polypropylene (PP), and fire retardant (FR) powders with maleic anhydride-grafted PP (2...

  8. Maximum Constrained Directivity of Oversteered End-Fire Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Andrea Trucco

    2015-06-01

    Full Text Available For linear arrays with fixed steering and an inter-element spacing smaller than one half of the wavelength, end-fire steering of a data-independent beamformer offers better directivity than broadside steering. The introduction of a lower bound on the white noise gain ensures the necessary robustness against random array errors and sensor mismatches. However, the optimum broadside performance can be obtained using a simple processing architecture, whereas the optimum end-fire performance requires a more complicated system (because complex weight coefficients are needed. In this paper, we reconsider the oversteering technique as a possible way to simplify the processing architecture of equally spaced end-fire arrays. We propose a method for computing the amount of oversteering and the related real-valued weight vector that allows the constrained directivity to be maximized for a given inter-element spacing. Moreover, we verify that the maximized oversteering performance is very close to the optimum end-fire performance. We conclude that optimized oversteering is a viable method for designing end-fire arrays that have better constrained directivity than broadside arrays but with a similar implementation complexity. A numerical simulation is used to perform a statistical analysis, which confirms that the maximized oversteering performance is robust against sensor mismatches.

  9. Properties of fired clay brick incorporating with sewage sludge waste

    Science.gov (United States)

    Kadir, Aeslina Abdul; Salim, Nurul Salhana Abdul; Sarani, Noor Amira; Rahmat, Nur Aqma Izurin; Abdullah, Mohd Mustafa Al Bakri

    2017-09-01

    The production of sludge in wastewater treatment plant is about to increase every year and most of the sludge was directly disposed to landfill. In addition, the constraint to treat sludge is very high in cost and time- consuming could be disadvantages to the responsible parties. Therefore, this research was conducted to utilize sludge produced from the wastewater treatment plant into fired clay brick as one of the alternatives of disposal method. In this study, the research attempt to incorporate sewage sludge waste (SSW) into fired clay brick. The sewage sludge brick (SSB) mixtures were incorporated with 0%, 1%, 5%, 10%, and 20% of SSW. The manufactured bricks were fired at 1050°C with heating rate of 1°C/min. Physical and mechanical properties test were conducted such as shrinkage, density, water absorption and compressive strength. As the conclusion, brick with utilization 5% of SSW is acceptable to produce good quality of brick. This study shows by using SSW in fired clay brick could be an alternative method to dispose of the SSW and also could act as a replacement material for brick manufacturing with appropriate mix and design.

  10. Equilibrium and response properties of the integrate-and-fire neuron in discrete time

    Directory of Open Access Journals (Sweden)

    Moritz Helias

    2010-01-01

    Full Text Available The integrate-and-fire neuron with exponential postsynaptic potentials is a frequently employed model to study neural networks. Simulations in discrete time still have highest performance at moderate numerical errors, which makes them first choice for long-term simulations of plastic networks. Here we extend the population density approach to investigate how the equilibrium and response properties of the leaky integrate-and-fire neuron are affected by time discretization. We present a novel analytical treatment of the boundary condition at threshold, taking both discretization of time and finite synaptic weights into account. We uncover an increased membrane potential density just below threshold as the decisive property that explains the deviations found between simulations and the classical diffusion approximation. Temporal discretization and finite synaptic weights both contribute to this effect. Our treatment improves the standard formula to calculate the neuron’s equilibrium firing rate. Direct solution of the Markov process describing the evolution of the membrane potential density confirms our analysis and yields a method to calculate the firing rate exactly. Knowing the shape of the membrane potential distribution near threshold enables us to devise the transient response properties of the neuron model to synaptic input. We find a pronounced non-linear fast response component that has not been described by the prevailing continuous time theory for Gaussian white noise input.

  11. How to increase fire safety in buildings: Fire safety engineering

    NARCIS (Netherlands)

    Herpen, van R.A.P. (Ruud)

    2011-01-01

    Fire means beside direct (financial)damage often far more indirect costs caused by interruption of operations and loss in sales, market share, property and,in the worst case people can get injured or even get killed (on average around80 persons a year). Fire in buildings is clearly a disaster and

  12. Wildland fire ash: future research directions

    Science.gov (United States)

    Bodí, Merche B.; Martins, Deborah A.; Cerdà, Artemi; Balfour, Victoria N.; Santin, Cristina; Doerr, Stefan H.; Pereira, Paulo; Mataix-Solera, Jorge

    2014-05-01

    Ash is a key component of the forest fires affected land (Cerdà, 1998; Bodí et al., 2011; Pereira et al., 2013a). Ash controls the hydrological processes and determines the water repellency (Dlapa et al., 2012) and the infiltration rates (Cerdà and Doerr, 2008;). Moreover, ash is the key factor on runoff initiation and then on the soil erosion. Little is known about the impact of ash in different ecosystems, but during the last decade a substantial increase in the papers that show the role of ash in the Earth and Soil System were published (Bodí et al., 2012; Pereira et al., 2013b).. Ash is being found as the key component of the post-fire pedological, geomorphological and hydrological response after forest fires (Fernández et al., 2012; Martín et al., 2012; Bodí et al., 2013; Guénon et al., 2013; Pereira et al., 2013c). A recent State-of-the-Art review about wildland fire ash (Bodí et al., 2014) compiles the knowledge regarding the production, composition and eco-hydro-geomorphic effects of wildland fire ash. In the present paper we indicate the knowledge gaps detected and suggest topics that need more research effort concerning: i) data collection and analysis techniques: a) To develop standardized sampling techniques that allow cross comparison among sites and avoid inclusion of the underlying soil unless the burned surface soil forms part of the ash layer, b) To develop standardized methods to define and characterize ash, including its color, physical properties such as particle size distribution or density, proportion of pyrogenic C, chemical and biological reactivity and persistence in the environment, c) To validate, calibrate and test measurements collected through remote sensing with on-the-ground measurements. ii) ash production, deposition redistribution and fate: d) To untangle the significance of the effects of maximum temperature reached during combustion versus the duration of heating, e) To understand the production of ash by measuring its

  13. Evaluation of post fire changes in soil properties and influence on the hydrological and erosive dynamics in a Mediterranean watershed

    Science.gov (United States)

    Sanz, Inés; Aguilar, Cristina; Millares, Agustín

    2013-04-01

    In the last fifty years, forest fires and changes in land use and management practices have had a significant influenceon the evolution of soil loss processes in the Mediterranean area. Forest fires have immediate effects in hydrological processes mainly due to sudden changes in soil properties and vegetation cover. After a fire there is an increase in runoff processes and peak flows and thus in the amount and composition of the sediments produced. Silting in dams downstream is often reported so the description of the post-fire hydrological processes is crucial in order to optimize decision making. This study analyzes a micro-watershed of 25 ha in the south of Spain that suffered a fire in October 2010 burning around a 2 km2 area. As the erosive processes in this area are directly related to concentrated overland flow, an indirect assessment of soil loss is presented in this work based on evaluating changes in runoff in Mediterranean post-fire situations. For this, the study is divided into two main parts. Firstly, changes in soil properties and vegetation cover are evaluated. Secondly, the effects of these changes in the hydrological and erosive dynamics are assessed.The watershed had been monitored in previous studies so soil properties and the vegetation cover before the fire took place were already characterized. Besides, the hydrological response was also available through an already calibrated and validated physically-based distributed hydrological model. For the evaluation of soil properties, field measurement campaigns were designed. Philip Dunne's tests for the determination of saturated hydraulic conductivity, as well as moisture content and bulk density measurements were carried out in both unaltered and burned soil samples. Changes in the vegetation cover fraction were assessed through desktop analysis of Landsat-TM5 platform satellite images as well as through visual inspection in the field campaigns. The analysis of the hydraulic conductivity revealed

  14. Properties of flat-pressed wood plastic composites containing fire retardants

    Science.gov (United States)

    Nadir Ayrilmis; Jan. T. Benthien; Heiko Thoemen; Robert H. White

    2011-01-01

    This study investigated physical, mechanical, and fire properties of the flat-pressed wood plastic composites (WPCs) incorporated with various fire retardants (FRs) [5 or 15% by weight (wt)] at 50 wt % of the wood flour (WF). The WPC panels were made from dry-blended WF, polypropylene (PP) with maleic anhydride grafted PP (2 wt %), and FR powder formulations using a...

  15. Impact of a low intensity controlled-fire in some chemical soil properties.

    Science.gov (United States)

    Martínez-Murillo, Juan F.; Hueso-González, Paloma; Aranda-Gómez, Francisco; Damián Ruiz-Sinoga, José

    2014-05-01

    Some changes in chemical soil properties can be observed after fires of low intensities. pH and electric conductivity tend to increase, while C/N ratio decrease. In the case of organic matter, the content can increase due to the massive incorporation of necromass including, especially, plants and roots. The aim of this study is to assess the impact of low intensity and controlled fire in some soil properties in field conditions. El Pinarillo experimental area is located in South of Spain. Two set of closed plots were installed (24 m2: 12 m length x 2 m width). One of them was remained as control with the original vegetation cover (Mediterranean matorral: Rosmarinus officinalis, Cistus clusii, Lavandula stoechas, Chamaeropos humilis, Thymus baetica), and the other one was burnt in a controlled-fire in 2011. Weather conditions and water content of vegetation influenced in the intensity of fire (low). After the controlled-fire, soil surface sample (0-5 cm) were taken in both set of plots (B, burnt soil samples; C, control soil samples). Some soil chemical properties were analysed: organic matter content (OM), C/N ratio, pH and electrical conductivity (EC). Some changes were observed in B corroborating a controlled-fire of low intensity. pH remained equal after fire (B: pH=7.7±0.11; C: pH=7.7±0.04). An increment was obtained in the case of EC (B: EC=0.45 mScm-1±0.08 mScm-1; C: EC=0.35 mScm-1±0.07 mScm-1) and OM (B: OM=8.7%±3.8%; C: pH=7.3%±1.5%). Finally, C/N ratio decreased after fire respect to the control and initial conditions (B: C/N=39.0±14.6; C: C/N =46.5±10.2).

  16. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    Energy Technology Data Exchange (ETDEWEB)

    Amir, N., E-mail: norlailiamir@petronas.com.my; Othman, W. M. S. W., E-mail: wamosa@gmail.com; Ahmad, F., E-mail: faizahmad@petronas.com.my [Mechanical Engineering Department, Universiti Teknologi PETRONAS Bandar Seri Iskandar, 31750 Tronoh, Perak (Malaysia)

    2015-07-22

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.

  17. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    International Nuclear Information System (INIS)

    Amir, N.; Othman, W. M. S. W.; Ahmad, F.

    2015-01-01

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating

  18. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    Science.gov (United States)

    Amir, N.; Othman, W. M. S. W.; Ahmad, F.

    2015-07-01

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.

  19. [Patterns of action potential firing in cortical neurons of neonatal mice and their electrophysiological property].

    Science.gov (United States)

    Furong, Liu; Shengtian, L I

    2016-05-25

    To investigate patterns of action potential firing in cortical heurons of neonatal mice and their electrophysiological properties. The passive and active membrane properties of cortical neurons from 3-d neonatal mice were observed by whole-cell patch clamp with different voltage and current mode. Three patterns of action potential firing were identified in response to depolarized current injection. The effects of action potential firing patterns on voltage-dependent inward and outward current were found. Neurons with three different firing patterns had different thresholds of depolarized current. In the morphology analysis of action potential, the three type neurons were different in rise time, duration, amplitude and threshold of the first action potential evoked by 80 pA current injection. The passive properties were similar in three patterns of action potential firing. These results indicate that newborn cortical neurons exhibit different patterns of action potential firing with different action potential parameters such as shape and threshold.

  20. Evaluation of correlation between physical properties and ultrasonic pulse velocity of fired clay samples.

    Science.gov (United States)

    Özkan, İlker; Yayla, Zeliha

    2016-03-01

    The aim of this study is to establish a correlation between physical properties and ultrasonic pulse velocity of clay samples fired at elevated temperatures. Brick-making clay and pottery clay were studied for this purpose. The physical properties of clay samples were assessed after firing pressed clay samples separately at temperatures of 850, 900, 950, 1000, 1050 and 1100 °C. A commercial ultrasonic testing instrument (Proceq Pundit Lab) was used to evaluate the ultrasonic pulse velocity measurements for each fired clay sample as a function of temperature. It was observed that there became a relationship between physical properties and ultrasonic pulse velocities of the samples. The results showed that in consequence of increasing densification of the samples, the differences between the ultrasonic pulse velocities were higher with increasing temperature. These findings may facilitate the use of ultrasonic pulse velocity for the estimation of physical properties of fired clay samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A NOVEL FIRE RETARDANT AFFECTS FIRE PERFORMANCE AND MECHANICAL PROPERTIES OF WOOD FLOUR-HIGH DENSITY POLYETHYLENE COMPOSITES

    Directory of Open Access Journals (Sweden)

    Mingzhu Pan,

    2012-02-01

    Full Text Available Wood flour-high density polyethylene (HDPE composites were prepared to investigate the effects of ammonium polyphosphate based fire retardant content (2, 4, 6, 8, and 10-wt%, on the flammability, mechanical, and morphological properties of the wood flour-HDPE composites in this study. Cone calorimetry analysis showed that the addition of fire retardant could decrease the heat release rate (HRR and total smoke release of wood flour-HDPE composites, while it had no obviously effects on effective heat of combustion. Most of the decrease of the HRR occurred with the concentration of the fire retardant up to 4-wt%. With addition of fire retardant, the composites showed a decrease in tensile elongation at break and impact strength, and had no obvious effect on tensile and flexural strength. The scanning electron microscopy observation on the fracture surface of the composites indicated that fire retardant had a uniform dispersion in the wood flour-HDPE composites. However, interfacial bonding would be suggested to improve in wood flour-HDPE composites with ammonium polyphosphate based fire retardant.

  2. Mapping fire effects on ash and soil properties. Current knowledge and future perspectives.

    Science.gov (United States)

    Pereira, Paulo; Cerda, Artemi; Strielko, Irina

    2014-05-01

    Fire has heterogeneous impacts on ash and soil properties, depending on severity, topography of the burned area, type of soil and vegetation affected, and meteorological conditions during and post-fire. The heterogeneous impacts of fire and the complex topography of wildland environments impose the challenge of understand fire effects at diverse scales in space and time. Mapping is fundamental to identify the impacts of fire on ash and soil properties because allow us to recognize the degree of the fire impact, vulnerable areas, soil protection and distribution of ash and soil nutrients, important to landscape recuperation. Several methodologies have been used to map fire impacts on ash soil properties. Burn severity maps are very useful to understand the immediate and long-term impacts of fire on the ecosystems (Wagtendonk et al., 2004; Kokaly et al., 2007). These studies normally are carried out with remote sensing techniques and study large burned areas. On a large scale it is very important to detect the most vulnerable areas (e.g. with risk of runoff increase, flooding, erosion, sedimentation and debris flow) and propose -if necessary- immediate rehabilitation measures. Post-fire rehabilitation measures can be extremely costly. Thus the identification of the most affected areas will reduce the erosion risks and soil degradation (Miller and Yool, 2002; Robichaud et al., 2007; Robichaud, 2009), as the consequent economical, social and ecological impacts. Recently, the United States Department of Agriculture created a field guide to map post-fire burn severity, based on remote sensing and Geographical Information Systems (GIS) technologies. The map produced should reflect the effects of fire on soil properties, and identify areas where fire was more severe (Parsons et al. 2010). Remote sensing studies have made attempts to estimate soil and ash properties after the fire, as hydrophobicity (Lewis et al., 2008), water infiltration (Finnley and Glenn, 2010), forest

  3. Impact of the post fire management in some soil chemical properties. First results.

    Science.gov (United States)

    Francos, Marcos; Pereira, Paulo; Alcañiz, Meritxell; Úbeda, Xavi

    2016-04-01

    Post-fire management after severe wildfires has impact on soil properties. In Mediterranean environments management of fire affected areas is a common practice. This intervention may change soil chemical properties of the soil such as major cations. The aim of this work is to study the impact of different types of forest management in soil extractable calcium, magnesium, sodium and potassium after a severe wildfire. The study area is located in Ódena (Catalonia, Spain). The wildfire occurred at July 27th of 2015 and burned 1235 ha. After the fire an experimental plot was designed 9 plots with 2x2 meters (4 square meters). The different managements were: a) clear-cuted area and wood removed, b) no treatment); and c) clear-cutted. The results of the first sampling showed significant differences among all treatments in extractable calcium, sodium and potassium. The amount of these extractable elements was high in clear-cutted treatment in comparison to the others. No differences were identified in extractable magnesium. Overall, in the immediate period after the fire, burned area management, changed the studied soil properties. We are currently studying the evolution of this soil properties in these plots with the time

  4. The importance of fire simulation in fire prediction

    Directory of Open Access Journals (Sweden)

    Jevtić Radoje B.

    2014-01-01

    Full Text Available The appearance of fire in objects with lot of humans inside represents very possible real situation that could be very danger and could cause destructive consequences on human lives and material properties. Very important influence in fire prediction, fire protection, human and material properties safety could be a fire simulation in object. This simulation could give many useful information of possible fire propagation; possible and existed evacuation routes; possible and exited placing of fire, smoke, temperature conditions in object and many other information of crucial importance for human lives and material properties, such as the best places for sensors position, optimal number of sensors, projection of possible evacuation routes etc. There are many different programs for fire simulation. This paper presents complete fire simulation in Electrotechnical school Nikola Tesla in Niš in FDS.

  5. Oriented clay nanopaper from biobased components--mechanisms for superior fire protection properties.

    Science.gov (United States)

    Carosio, F; Kochumalayil, J; Cuttica, F; Camino, G; Berglund, L

    2015-03-18

    The toxicity of the most efficient fire retardant additives is a major problem for polymeric materials. Cellulose nanofiber (CNF)/clay nanocomposites, with unique brick-and-mortar structure and prepared by simple filtration, are characterized from the morphological point of view by scanning electron microscopy and X-ray diffraction. These nanocomposites have superior fire protection properties to other clay nanocomposites and fiber composites. The corresponding mechanisms are evaluated in terms of flammability (reaction to a flame) and cone calorimetry (exposure to heat flux). These two tests provide a wide spectrum characterization of fire protection properties in CNF/montmorrilonite (MTM) materials. The morphology of the collected residues after flammability testing is investigated. In addition, thermal and thermo-oxidative stability are evaluated by thermogravimetric analyses performed in inert (nitrogen) and oxidative (air) atmospheres. Physical and chemical mechanisms are identified and related to the unique nanostructure and its low thermal conductivity, high gas barrier properties and CNF/MTM interactions for char formation.

  6. Effect of Nano bentonite on Fire Retardant Properties of Medium density fiberboard (MDF

    Directory of Open Access Journals (Sweden)

    Ghonche Rassam

    2014-05-01

    Full Text Available In the present study, Fire – Retarding properties of nano-bentonite in medium density of fiberboard (MDF was studied. 10% of urea-formaldehyde resin was used as the adhesive of the matrix. Nano Bentonite at 5 levels (0%, 5%, 10%, 15% and 20% g/kg based of dry weight of fibers was used with the consumption of Urea-Formuldehyde (UF. Press pressure of 150 bar and temperature of 170during 4, 5, and 6 minutes were applied. Density was kept constant at 0.7 g/cm3 in all treatments. The measured properties consisted of mass reduction, inflammation time, fire-endurance, melting time and the burnt area. The results revealed that Nano-Bentonite had significant effect in approving fire retarding properties in medium density fiber board. The best properties at the level of 10% obtained and the same level recommended for industry use. The use of Nano-Bentonite more than 10% decreased the stickiness and the partly surface of fiberboards.

  7. Barriers to community-directed fire restoration

    Science.gov (United States)

    R. Bruce Hull; Bruce E. Goldstein

    2006-01-01

    Wild fire disasters create novel situations and challenges for natural resource managers, including working with emergent community groups that have a great deal of motivation for change, little familiarity with agency protocol, and strong preferences for the goals and methods of forest fire restoration, some of which may run counter to agency norms. After a fire,...

  8. Influence of long-term storage on fire hazard properties of metal nanopowders

    Science.gov (United States)

    Kyrmakova, O. S.; Sechin, A. I.; Nazarenko, O. B.

    2017-08-01

    The production and application of nanomaterials is rapidly expanding. Therefore the problem of their properties change during long-term storage becomes essential. The properties of metal nanopowders after long-term storage under ambient conditions were studied and the results are presented in this work. The aluminum, iron, zinc, and copper nanopowders produced by the method of electrical explosion of wires were investigated in this work. The investigation was carried out by X-ray and thermal analysis. The estimation of the flame propagation velocity in the bulk layer of nanopowders was carried out. The characteristics of the nanopowders of nanometals studied are given in terms of their fire hazard. The results can be used for diagnostic of fire hazard of nanomaterials and protection of the enterprises against fire and explosion.

  9. Biological properties of soils of former forest fires in Samosir Regency of North Sumatera

    Directory of Open Access Journals (Sweden)

    D. Elfiati

    2016-04-01

    Full Text Available A study that was aimed to identify the impact of forest fires on the biological properties of soils was carried out at former forest fire areas in Samosir Regency of North Sumatera. Soil samples were collected from former forest fire areas of 2014, 2013, 2012, 2011, 2010. The composite soil samples were collected systematically using diagonal method as much as 5 points in each period of fire. The soil samples were taken at three plots measuring 20 x 20 m 0-20 cm depth. Soil biological properties observed were soil organic C content, total number of microbes, abundance of arbuscular mycorrhizal fungi, phosphate solubilizing microbes, and soil microbial activity. The results showed that organic C content ranged from 0.75 to 2.47% which included criteria for very low to moderate. Arbuscular mycorrhizal fungi spores were found belonging to the genus of Glomus and Acaulospora. Spore number increased with the fire period ranging from 45 spores (forest fire in 2014 to 152 spores (forest fire in 2010. The total number of microbes obtained ranged from 53.78 x 107 cfu/mL (forest fire in 2010 to 89.70 x107 cfu/mL (forest fire in 2013. It was found 29 isolates of phosphate solubilizing microbes that consisted of 14 bacterial isolates and 15 fungi isolates with densities ranging from 27.642 x105 cfu/mL (forest fires in 2014 to 97.776 x 105 cfu/ mL (forest fires in 2011. The isolates of phosphate solubilizing bacteria identified consisted of Pseudomonas, Flavobacterium, Staphylococcus, and Mycobacterium genus, whereas the isolates of phosphate solubilizing fungi obtained consisted of Aspergillus and Penicillium genus. Soil respiration ranged from 2.14 kg / day (forest fire in 2010 up to 3.71 kg / day (forest fire in 2013. The varied results were greatly influenced by the type or form of the fires and intensity of fires. In the study area the type or form of the fires were canopy fires with low intensity.

  10. Effect of high temperature or fire on heavy weight concrete properties

    International Nuclear Information System (INIS)

    Sakr, K.; EL-Hakim, E.

    2005-01-01

    Temperature plays an important role in the use of concrete for shielding nuclear reactors. In the present work, the effect of different durations (1, 2 and 3 h) of high temperatures (250, 500, 750 and 950 deg. C) on the physical, mechanical and radiation properties of heavy concrete was studied. The effect of fire fitting systems on concrete properties was investigated. Results showed that ilmenite concrete had the highest density, modulus of elasticity and lowest absorption percent, and it had also higher values of compressive, tensile, bending and bonding strengths than gravel or baryte concrete. Ilmenite concrete showed the highest attenuation of transmitted gamma rays. Firing (heating) exposure time was inversely proportional to mechanical properties of all types of concrete. Ilmenite concrete was more resistant to elevated temperature. Foam or air proved to be better than water as a cooling system in concrete structure exposed to high temperature because water leads to a big damage in concrete properties

  11. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  12. Effects of firing temperature on the properties of ceramics produced from a clay tailings

    International Nuclear Information System (INIS)

    Oliveira, V.M.C.A.; Vidal, A.B.; Ribeiro, S.

    2012-01-01

    The aim of this study was to evaluate the properties of ceramics produced by the firing of a tailing from a clay mining of quartz sand for their application in construction, primarily in the floors and walls. The waste was pressed and the compacts were fired at 1000, 1100, 1200, 1300, 1400 and 1500°C. The results showed linear shrinkage (RL) and water absorption (AA) ranging from 0.5 to 6.5% and 16.4 to 0.5%, respectively. It was also decreased porosity and bulk density increased with increasing treatment temperature. In the analyzes of fracture was observed increase cohesion between particles and connections of the reduction in porosity with increasing firing temperature. The sample showed a better set of mechanical properties of the sample was fired at 1300°C, and present the best appearance. (author)

  13. The influence of fire retardants on the properties of beech and poplar veneers and plywood

    Directory of Open Access Journals (Sweden)

    Miljković Jovan

    2005-01-01

    Full Text Available Rising demands for fire resistance properties of wood construction and elements matching new standards have been an important part of building codes during the last decade. On the other side, lack of more detailed research on interaction between wood species and selected fire retardant chemicals even with basically one is evident. This is particularly truth with domestic wood species. In this research, beech and poplar veneers were immersed in 25% solutions of monoammonium phosphate (MP and sodium acetate (SA and impregnated for different periods of time. To determine the preliminary level of fire retardancy achieved in veneers before manufacturing of finished plywood, thermo gravimetric (TG and derivative thermo gravimetric (DTG methods were used. TG and DTG analyses of treated and untreated wood, as well as of fire retardants alone, were performed. The next properties of impregnated and no impregnated veneers and plywood were determined: absorption of imp regnant solution (A, weight percent gain (WPG of imp regnant, equilibrium moisture content (EMC, pH values, and in the case of plywood, strength and fire resistance. Fire resistance of plywood was tested in accordance with standard test for resistance to the effects of fire and the most efficient fire retardant, monoammonium phosphate, had the same result as TG/DTG analyses, which pointed out the validity of TG methods in predicting fire resistance of future products.

  14. Fire-retardant-treated strandboard : properties and fire performance

    Science.gov (United States)

    Jerrold Winandy; Qingwen Wang; Robert H. White

    2008-01-01

    This study evaluated a series of single-layer, randomly oriented strandboard panels made with one resin type, a single resin loading level, and four fire-retardant-treatment levels. The fire retardant (FR) evaluated was a pH-buffered combination of boric acid and organic phosphate. Siberian larch strands were separated into five batches. One batch of strands served as...

  15. Investigation into the dissolution and direct assay of high-fired plutonium dioxide

    International Nuclear Information System (INIS)

    Patterson, J.K.

    1976-01-01

    A fusion-melt and dissolution assay method has been developed and tested for the quantitative analysis of high-fired plutonium dioxide. The method employs fusion of the plutonium dioxide at temperatures greater than the melting point of an eutectic mixture of potassium pyrosulfate plus sodium peroxide. The resultant melt is then titrated directly by either controlled potential coulometry or a gravimetric titration, using standardized ceric sulfate as the titrant. It has been concluded from these investigations that by using the techniques described, high-fired plutonium dioxide (stochiometric) can be quantitatively dissolved and assayed to a degree heretofore beyond the state-of-the-art, while showing direct traceability to the Federal standards. After fusion, the dissolution and direct assay is applicable to existing routine analytical procedures. The method was designed so as to minimize physical handling, simplify the chemical operations, and maximize the personal safety of the analyst at an appreciable cost savings per analysis

  16. Prescribed fires effects on physico-chemical properties and quantity of runoff and soil erosion in a Mediterranean forest

    Science.gov (United States)

    Esteban Lucas-Borja, Manuel; Plaza Alvaréz, Pedro Antonio; Sagra, Javier; Alfaro Sánchez, Raquel; Moya, Daniel; Ferrandiz Gotor, Pablo; De las Heras Ibañez, Jorge

    2017-04-01

    Wildfires have an important influence in forest ecosystems. Contrary to high severity fire, which may have negative impacts on the ecosystems, low severity induce small changes on soil properties. Thus and in order to reduce fire risk, low-severity prescribed fires have been widely used as a fuel reduction tool and silvicultural treatment in Mediterranean forest ecosystems. However, fire may alter microsite conditions and little is known about the impact of prescribed burning on the physico-chemical properties of runoff. In this study, we compared the effects of prescribed burning on physico-chemical properties and quantity of runoff and soil erosion during twelve months after a low severity prescribed fire applied in twelve 16 m2 plot (6 burned plots and 6 control plots used for comparison) set up in the Lezuza forest (Albacete, central-eastern Spain). Physico-chemical properties and quantity of runoff and soil losses were monitored after each rainfall event (five rainfall events in total). Also, different forest stand characteristics (slope, tree density, basal area and shrub/herbal cover) affecting each plot were measured. Results showed that forest stand characteristics were very similar in all used plots. Also, physico-chemical runoff properties were highly modified after the prescribed fire, increasing water pH, carbonates, bicarbonates, total dissolved solids and organic matter content dissolved in water. Electrical conductivity, calcium, sodium, chloride and magnesium were not affected by prescribed fire. Soil losses were highly related to precipitation intensity and tree interception. Tree intercepted the rainfall and significantly reduced soil losses and also runoff quantity. In conclusion and after the first six-month experiment, the influence of prescribed fires on physico-chemical runoff properties should be taken into account for developing proper prescribed burnings guidelines.

  17. Nuclear power plants: a unique challenge to fire safety

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1992-01-01

    The evaluation of fire safety in a nuclear power plant must include the consideration of the impact of a fire on the operability of plant safety equipment and systems. This issue is not typical of the life safety and property protection issues which dominate traditional fire safety concerns. This paper provides a general discussion of the issue of nuclear power plant fire safety as it currently exists in the USA. Included is a discussion of the past history of nuclear power plant fire events, the development of nuclear industry specific fire safety guidelines, the adverse experience associated with the inadvertent operation of fire suppression systems, and the anticipated direction of fire safety requirements for future reactor designs in the USA. (Author)

  18. Measurement of temperature distributions in large pool fires with the use of directional flame thermometers

    International Nuclear Information System (INIS)

    Koski, Jorman A.

    2000-01-01

    Temperatures inside the flame zone of large regulatory pool fires measured during tests of radioactive materials packages vary widely with both time and position. Measurements made with several Directional Flame Thermometers, in which a thermocouple is attached to a thin metal sheet that quickly approaches flame temperatures, have been used to construct fire temperature distributions and cumulative probability distributions. As an aid to computer simulations of these large fires, these distributions are presented. The distributions are constructed by sorting fire temperature data into bins 10 C wide. A typical fire temperature distribution curve has a gradual increase starting at about 600 C, with the number of observations increasing to a peak near 1000 C, followed by an abrupt decrease in frequency, with no temperatures observed above 1200 C

  19. A Study on Spreading Direction of Coal-fire Based with TIR Remote Sensing in Wuda Coalfield from 2000 to 2006, Northern China

    International Nuclear Information System (INIS)

    Huo, H-Y; Jiang, X-G; Song, X-F; Liu, L; Ni, Z-Y; Gao, C-X; Zhang, Y-Z

    2014-01-01

    Coal fires are a common and serious problem in most coal producing countries. Coal fires could not only lead to a huge loss of non-renewable energy resources, but it also can cause many environmental problems such as GHG emission, land subsidence and increment of surface temperature. So it is very important to monitor the dynamic changes of coal fires. As far as large scale coal field, remote sensing provided researchers with a new and useful technique for coal fire detection. This paper developed a research over coal fire spreading direction using a multi-temporal TIR remote sensing approach. The results successfully showed that the direction of coal fire spreading and predicted the coal fire direction of development on a regional scale or on a whole coal field scale, and a quantitative analysis of coal fires was made in the research. The results showed that the coal fires had an average annual increase of 0.5 million square meters from 1999 to 2006, and the TIR remote sensing proved to be an available tool for coal fire mapping and prediction of coal fire development

  20. Investigations of bi-directional flow behaviour in presence of a large vertical opening in a fire compartment

    International Nuclear Information System (INIS)

    Sharma, Pavan K.; Gera, B.

    2011-01-01

    In the complex thermal hydraulics codes developed for fire, reactor and containment safety the junctions in the multi-compartment geometries are often modeled as uni-directional junctions and some construct of flow coefficient. However, certain large size junctions are known to depict bi-directional flow behaviour under specific circumstances. The CFD based computer code FDS was used for an earlier reported study of fire in an enclosure on the bidirectional flow behaviour in present of a wall opening. Numerical simulation is directed to monitor the entrainment of the fresh air from outside to the fire compartment and resulting plume deflection due to presence of a big opening. The paper presents the details of the analysis, the results obtained, and comparison with the reported experimental data in terms of plume deflection, entrainment. Detailed investigations have been carried out to understand the bi-directionality of a junction by analyzing studying the outgoing hot air flow and incoming cold air. (orig.)

  1. Operational experiences of (in)direct co-combustion in coal and gas fired power plants in Europe

    International Nuclear Information System (INIS)

    Van Ree, R.; Korbee, R.; Meijer, R.; Konings, T.; Van Aart, F.

    2001-02-01

    The operational experiences of direct and indirect co-combustion of biomass/waste in European coal and natural gas fired power plants are addressed. The operational experiences of mainly Dutch direct co-combustion activities in coal fired power plants are discussed; whereas an overview of European indirect co-combustion activities is presented. The technical, environmental, and economic feasibility of different indirect co-combustion concepts (i.e. upstream gasification, pyrolysis, combustion with steam-side integration) is investigated, and the results are compared with the economic preferable concept of direct co-combustion. Main technical constraints that limit the co-combustion capacity of biomass/waste in conventional coal fired power plants are: the grindability of the biomass/coal blend, the capacity of available unit components, and the danger of severe slagging, fouling, corrosion and erosion. The main environmental constraints that have to be taken into account are the quality of produced solid waste streams (fly ash, bottom ash, gypsum) and the applicable air emission regulations. 6 refs

  2. Firing properties of identified interneuron populations in the mammalian hindlimb central pattern generator

    DEFF Research Database (Denmark)

    Butt, S. J B; Harris-Warrick, Ronald M.; Kiehn, Ole

    2002-01-01

    a heterogenous population with neurons that fired in all phases of the locomotor cycle and exhibited varying degrees of rhythmicity, from strongly rhythmic to nonrhythmic. Among the rhythmic, putative CPG dCINs were populations that fired inphase with the ipsilateral or with the contralateral L2 locomotorlike......, with little direct contribution from the intrinsic pacemaker hyperpolarization-activated inward current. For both ipsilaterally and contralaterally firing dCINs the dominant synaptic drive was in-phase with the ipsilateral L2 motor activity. This study provides the first characterization of putative CPG...

  3. Resolving vorticity-driven lateral fire spread using the WRF-Fire coupled atmosphere–fire numerical model

    OpenAIRE

    Simpson, C. C.; Sharples, J. J.; Evans, J. P.

    2014-01-01

    Fire channelling is a form of dynamic fire behaviour, during which a wildland fire spreads rapidly across a steep lee-facing slope in a direction transverse to the background winds, and is often accompanied by a downwind extension of the active flaming region and extreme pyro-convection. Recent work using the WRF-Fire coupled atmosphere-fire model has demonstrated that fire channelling can be characterised as vorticity-driven lateral fire spread (VDLS). In t...

  4. Study on Fired Clay Bricks by Replacing Clay with Palm Oil Waste: Effects on Physical and Mechanical Properties

    Science.gov (United States)

    Kadir, A. A.; Sarani, N. A.; Abdullah, M. M. A. B.; Perju, M. C.; Sandu, A. V.

    2017-06-01

    Palm oil is one of the major agricultural industries in Malaysia. Due to the poor management system, the discarded palm oil waste has always been linked to the environment issues. During processing of palm oil, a considerable amount of solid waste by-products in the form of fibres, shells, empty fruit bunches and fly ashes are produce rapidly. Therefore, this study was conducted to incorporate 1%, 5% and 10% of palm oil waste into fired clay brick. Samples of brick were fired at 1050°C temperature with heating rates of 1°C/min. Manufactured bricks were tested with physical and mechanical properties including firing shrinkage, dry density, water absorption and compressive strength. The results demonstrated that the replacement of 1% up to 5% of palm oil waste had improved several properties, although, a decrease of performance in certain aspects has also been observed. As a result, palm oil waste can be utilized in an environmentally safe way into fired clay brick thus providing adequate properties of fired clay brick.

  5. Soil heating in chaparral fires: effects on soil properties, plant nutrients, erosion, and runoff

    Science.gov (United States)

    Leonard F. DeBano; Raymond M. Rice; Conrad C. Eugene

    1979-01-01

    This state-of-the-art report summarizes what is known about the effects of heat on soil during chaparral fires. It reviews the literature on the effects of such fires on soil properties, availabilty and loss of plant nutrients, soil wettability, erosion, and surface runoff. And it reports new data collected during recent prescribed burns and a wildfire in southern...

  6. Chemical Solutions of Fire Protection Problems

    Directory of Open Access Journals (Sweden)

    Vakhitova, L.M.

    2015-11-01

    Full Text Available The modern approaches to the creation of fire protective coatings by modifying intumescent systems by nanomaterials with study of the chemical reaction mechanisms under the high temperatures influence were considered. A systematic study of the interactions of components of polyphosphate type intumescent blend were carried out, a well-defined correlations between the directions of chemical processes and fire retardant properties of intumescent coatings were found. Efficient ways to simultaneous increase of fireprotective efficiency and performance characteristics of intumescent coatings (operatin life, resistance to environmental factors and bioсontamination were proposed. The results of fundamental research allowed to develop new formulations of flame retardant compositions, whose properties have been confirmed by tests in accordance with existing standardized methods, these results were introduced into production.

  7. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    OpenAIRE

    Otto Dvořák

    2016-01-01

    This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  8. Burn Severity and Its Impact on Soil Properties: 2016 Erskine Fire in the Southern Sierra Nevada

    Science.gov (United States)

    Haake, S.; Guo, J.; Krugh, W. C.

    2017-12-01

    Wildfire frequency in the southern Sierra Nevada has increased over the past decades. The effects of wildfires on soils can increase the frequency of slope failure and debris flow events, which pose a greater risk to people, as human populations expand into foothill and mountainous communities of the Sierra Nevada. Alterations in the physical properties of burned soils are one such effect that can catalyze slope failure and debris flow events. Moreover, the degree of a soil's physical alteration resulting from wildfire is linked to fire intensity. The 2016 Erskine fire occurred in the southern Sierra Nevada, burning 48,019 acres, resulting in soils of unburned, low, moderate, and high burn severities. In this study, the physical properties of soils with varying degrees of burn severity are explored within the 2016 Erskine fire perimeter. The results constrain the effects of burn severity on soil's physical properties. Unburned, low, moderate, and high burn severity soil samples were collected within the Erskine fire perimeter. Alterations in soils' physical properties resulting from burn severity are explored using X-ray diffractometry analysis, liquid limit, plastic limit, and shear strength tests. Preliminary results from this study will be used to assess debris flow and slope failure hazard models within burned areas of the Kern River watershed in the southern Sierra Nevada.

  9. Effect of High Temperature or fire on heavy weight concrete properties used in nuclear facilities

    International Nuclear Information System (INIS)

    Sakr, K.

    2003-01-01

    In the present work the effect of different duration (1, 2 and 3 hours) of high temperatures (250 degree C, 500 degree C, 750 degree C and 950 degree C) on the physical and mechanical properties of heavy concrete shields were studied. The effect of fire fitting systems on ordinary concrete was investigated. The work was extended to determine the effect of high temperature or accidental fire on the radiation properties of heavy weight concrete. Results showed that ilmenite concrete had the highest density, absorption, and modulus of elasticity when compared to the other types of studied concrete and it had also higher values of compressive, tensile, bending and bonding strength than ordinary or baryte concrete. Ilmenite concrete had the highest attenuation of transmitted gamma rays in comparing to gravel concrete and baryte concrete. Ilmenite concrete was more resistant to elevated temperature than gravel concrete and baryte concrete. Foam or air as a fire fitting system in concrete structure that exposed to high temperature or accidental fire proved that better than water

  10. Experimental research on the residual mechanical properties of an ordinary concretes after fire

    OpenAIRE

    Santos, C.C.; Rodrigues, J.P.

    2015-01-01

    This paper summarizes the results of an experimental research to assess the residual mechanical properties of an ordinary concrete after fire. It was studied the influence of the cooling process, the maximum temperature that the concrete was subjected to and the loading level on the residual mechanical properties of calcareous and granite aggregate concretes. The properties studied were the residual compressive, tensile, splitting and flexural strengths and modulus of elasticit...

  11. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    Directory of Open Access Journals (Sweden)

    Otto Dvořák

    2016-07-01

    Full Text Available This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  12. Influence of the contractile properties of muscle on motor unit firing rates during a moderate-intensity contraction in vivo.

    Science.gov (United States)

    Trevino, Michael A; Herda, Trent J; Fry, Andrew C; Gallagher, Philip M; Vardiman, John P; Mosier, Eric M; Miller, Jonathan D

    2016-08-01

    It is suggested that firing rate characteristics of motor units (MUs) are influenced by the physical properties of the muscle. However, no study has correlated MU firing rates at recruitment, targeted force, or derecruitment with the contractile properties of the muscle in vivo. Twelve participants (age = 20.67 ± 2.35 yr) performed a 40% isometric maximal voluntary contraction of the leg extensors that included linearly increasing, steady force, and decreasing segments. Muscle biopsies were collected with myosin heavy chain (MHC) content quantified, and surface electromyography (EMG) was recorded from the vastus lateralis. The EMG signal was decomposed into the firing events of single MUs. Slopes and y-intercepts were calculated for 1) firing rates at recruitment vs. recruitment threshold, 2) mean firing rates at steady force vs. recruitment threshold, and 3) firing rates at derecruitment vs. derecruitment threshold relationships for each subject. Correlations among type I %MHC isoform content and the slopes and y-intercepts from the three relationships were examined. Type I %MHC isoform content was correlated with MU firing rates at recruitment (y-intercepts: r = -0.577; slopes: r = 0.741) and targeted force (slopes: r = 0.853) vs. recruitment threshold and MU firing rates at derecruitment (y-intercept: r = -0.597; slopes: r = 0.701) vs. derecruitment threshold relationships. However, the majority of the individual MU firing rates vs. recruitment and derecruitment relationships were not significant (P > 0.05) and, thus, revealed no systematic pattern. In contrast, MU firing rates during the steady force demonstrated a systematic pattern with higher firing rates for the lower- than higher-threshold MUs and were correlated with the physical properties of MUs in vivo. Copyright © 2016 the American Physiological Society.

  13. Effect of PFM Firing Cycles on the Mechanical Properties, Phase Composition, and Microstructure of Nickel-Chromium Alloy.

    Science.gov (United States)

    Anwar, Mohd; Tripathi, Arvind; Kar, Sushil Kumar; Sekhar, K Chandra

    2015-12-01

    The purpose of this study was to compare the mechanical properties of beryllium-free nickel-chromium (Ni-Cr) dental casting alloy before and after each porcelain firing cycle (once fired, twice fired, and thrice fired) and to relate these properties to the microstructural changes and changes in X-ray diffraction patterns of Ni-Cr alloy that occur after each porcelain firing cycle. Forty tensile bar specimens and 20 disc-shaped specimens of Ni-Cr alloy were prepared. These specimens were divided into four groups. The first group was not heat treated and tested in the as-cast condition, thus serving as control group. The second, third, and fourth groups were fired once, twice, and thrice, respectively. Tensile bar specimens were loaded to failure in tension using a universal testing machine. Values of ultimate tensile strength, 0.1% yield strength, and percentage elongations were determined. Microstructural study and hardness testing were done using an optical microscope and digital Vickers hardness tester, respectively, on disc-shaped specimens. Disc-shaped specimens were again used to obtain the X-ray diffraction patterns by using diffractometer Bruker D8 focus. Statistical comparisons of the mechanical properties and hardness of the alloy were made with ANOVA. Intergroup comparisons of the data in the as-cast and fired specimens were analyzed by applying Tukey's HSD multiple comparison tests. Before porcelain firing, the alloy exhibited higher ultimate tensile strength (548 MPa), 0.1% yield strength (327 MPa), hardness (192 HV), and lower elongation values (18%). After each firing cycle, there was a significant (p alloy. The microstructure of the control group specimen exhibited heterogeneous microstructure, and after each firing, microstructure of the alloy was gradually homogenized by formation of grain boundaries at the interdendritic interfaces. X-ray diffraction pattern shows that the alloy exhibited four strong diffraction peaks within the range of 2θ = 40

  14. How clear-cutting affects fire severity and soil properties in a Mediterranean ecosystem.

    Science.gov (United States)

    Francos, Marcos; Pereira, Paulo; Mataix-Solera, Jorge; Arcenegui, Victoria; Alcañiz, Meritxell; Úbeda, Xavier

    2018-01-15

    Forest management practices in Mediterranean ecosystems are frequently employed to reduce both the risk and severity of wildfires. However, these pre-fire treatments may influence the effects of wildfire events on soil properties. The aim of this study is to examine the short-term effects of a wildfire that broke out in 2015 on the soil properties of three sites: two exposed to management practices in different years - 2005 (site M05B) and 2015 (site M15B) - and one that did not undergo any management (NMB) and to compare their properties with those recorded in a plot (Control) unaffected by the 2015 wildfire. We analyzed aggregate stability (AS), soil organic matter (SOM) content, total nitrogen (TN), carbon/nitrogen ratio (C/N), inorganic carbon (IC), pH, electrical conductivity (EC), extractable calcium (Ca), magnesium (Mg), sodium (Na), and potassium (K), microbial biomass carbon (C mic ) and basal soil respiration (BSR). In the managed plots, a clear-cutting operation was conducted, whereby part of the vegetation was cut and left covering the soil surface. The AS values recorded at the Control site were significantly higher than those recorded at M05B, whereas the TN and SOM values at NMB were significantly higher than those recorded at M05B. IC was significantly higher at M05B than at the other plots. There were no significant differences in C/N ratio between the analyzed sites. Soil pH at M05B was significantly higher than the value recorded at the Control plot. Extractable Ca was significantly higher at NMB than at both M05B and the Control, while extractable Mg was significantly lower at M05B than at NMB. Extractable K was significantly lower at the Control than at the three fire-affected plots. C mic was significantly higher at NMB than at the Control. BSR, BSR/C and BSR/C mic values at the fire-affected sites were significantly lower than those recorded at the Control. No significant differences were identified in C mic /C. Overall, a comparison of the

  15. Impacts of fire, fire-fighting chemicals and post-fire stabilization techniques on the soil-plant system

    OpenAIRE

    Fernández Fernández, María

    2017-01-01

    Forest fires, as well as fire-fighting chemicals, greatly affect the soil-plant system causing vegetation loss, alterations of soil properties and nutrient losses through volatilization, leaching and erosion. Soil recovery after fires depends on the regeneration of the vegetation cover, which protects the soil and prevents erosion. Fire-fighting chemicals contain compounds potentially toxic for plants and soil organisms, and thus their use might hamper the regeneration of burnt ecosystems. In...

  16. Influence of heating rate and temperature firing on the properties of bodies of red ceramic

    International Nuclear Information System (INIS)

    Silva, B.J. da; Goncalves, W.P.; Cartaxo, J.M.; Macedo, R.S.; Neves, G.A.; Santana, L.N.L.; Menezes, R.R.

    2011-01-01

    In the red ceramic industry, the firing is one of the main stages of the production process. There are two heating rates prevailing at this stage: the slow (traditional ceramics) and fast. The slow rate more used in Brazil, is considered delayed. This study aims to evaluate the influence of particle size and chemical composition of three mixture of clay, used in the manufacture of red ceramic products and to study the influence of the firing temperature on their technological properties. When subjected to heating rates slow and fast. Initially, the mixtures were characterized subsequently were extruded, dried and subjected to firing at temperatures of 900 and 1000 ° C with heating rates of 5, 20 and 30 °C/min. The results indicated that the chemical composition and particle size influenced significantly the technological properties and that the bodies obtained with the paste that had lower levels of flux showed better stability. (author)

  17. Biomass co-firing

    DEFF Research Database (Denmark)

    Yin, Chungen

    2013-01-01

    Co-firing biomass with fossil fuels in existing power plants is an attractive option for significantly increasing renewable energy resource utilization and reducing CO2 emissions. This chapter mainly discusses three direct co-firing technologies: pulverized-fuel (PF) boilers, fluidized-bed combus......Co-firing biomass with fossil fuels in existing power plants is an attractive option for significantly increasing renewable energy resource utilization and reducing CO2 emissions. This chapter mainly discusses three direct co-firing technologies: pulverized-fuel (PF) boilers, fluidized......-bed combustion (FBC) systems, and grate-firing systems, which are employed in about 50%, 40% and 10% of all the co-firing plants, respectively. Their basic principles, process technologies, advantages, and limitations are presented, followed by a brief comparison of these technologies when applied to biomass co...

  18. 36 CFR 13.976 - Fire.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Fire. 13.976 Section 13.976 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK... (fda) § 13.976 Fire. Lighting or maintaining a fire is prohibited in the FDA except— (a) In established...

  19. Fire resistance of wood members with directly applied protection

    Science.gov (United States)

    Robert H. White

    2009-01-01

    Fire-resistive wood construction is achieved either by having the structural elements be part of fire-rated assemblies or by using elements of sufficient size that the elements themselves have the required fire-resistance ratings. For exposed structural wood elements, the ratings in the United States are calculated using either the T.T. Lie method or the National...

  20. Direct and indirect effects of fires on the carbon balance of tropical forest ecosystems (Invited)

    Science.gov (United States)

    Randerson, J. T.; Tosca, M. G.; Ward, D. S.; Kasibhatla, P. S.; Mahowald, N. M.; Hess, P. G.

    2013-12-01

    Fires influence the carbon budget of tropical forests directly because they account for a significant component of net emissions from deforestation and forest degradation. They also have indirect effects on nearby intact forests by modifying regional climate, atmospheric composition, and patterns of nutrient deposition. These latter pathways are not well understood and are often ignored in climate mitigation efforts such as the United Nations Program on Reducing Emissions from Deforestation and forest Degradation (REDD+). Here we used the Community Atmosphere Model (CAM5) and the Global Fire Emissions Database (GFED3) to quantify the impacts of fire-emitted aerosols on the productivity of tropical forests. Across the tropical forest biome, fire-emitted aerosols reduced surface temperatures and increased the diffuse solar insolation fraction. These changes in surface meteorology increased gross primary production (GPP) in the Community Land Model. However, these drivers were more than offset in many regions by reductions in soil moisture and total solar radiation. The net effect of fire aerosols caused GPP to decrease by approximately 8% in equatorial Asia and 6% in the central Africa. In the Amazon, decreases in photosynthesis in the western part of the basin were nearly balanced by increases in the south and east. Using additional CAM5 and GEOS-Chem model simulations, we estimated fire contributions to surface concentrations of ozone. Using empirical relationships between ozone exposure and GPP from field studies and models, we estimated how tropical forest GPP was further modified by fire-induced ozone. Our results suggest that efforts to reduce the fire component of tropical land use fluxes may have sustainability benefits that extend beyond the balance sheet for greenhouse gases.

  1. Fires, ecological effects of

    Science.gov (United States)

    W. J. Bond; Robert Keane

    2017-01-01

    Fire is both a natural and anthropogenic disturbance influencing the distribution, structure, and functioning of terrestrial ecosystems around the world. Many plants and animals depend on fire for their continued existence. Others species, such as rainforest plants species, are extremely intolerant of burning and need protection from fire. The properties of a fire...

  2. Fire science at LLNL: A review

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, H.K. (ed.)

    1990-03-01

    This fire sciences report from LLNL includes topics on: fire spread in trailer complexes, properties of welding blankets, validation of sprinkler systems, fire and smoke detectors, fire modeling, and other fire engineering and safety issues. (JEF)

  3. Post-fire regeneration in a Mediterranean pine forest with historically low fire frequency

    Science.gov (United States)

    Buhk, Constanze; Götzenberger, Lars; Wesche, Karsten; Gómez, Pedro Sánchez; Hensen, Isabell

    2006-11-01

    Species of Mediterranean vegetation are known to regenerate directly after fire. The phenomenon of autosuccession (direct regeneration) has been found to be often combined with an increase of species richness during the first years after fire due to the high abundance of short-lived herbaceous plants facilitated by plentiful nutrients and light. The high degree of vegetation resilience, which is expressed in terms of autosuccession, has been explained by the selective pressure of fire in historic times. According to existing palaeoecological data, however, the Pinus halepensis forests in the Ricote Mountains (Province of Murcia, SE Spain) did not experience substantial fire impact before the presence of man nor are they especially fire-prone today. Therefore, we studied post-fire regeneration to find out if direct succession is present or if species from pre-fire vegetation are absent during the post-fire regeneration stages. Patterns of succession were deduced from observations made in sample plots on sites of a known regeneration age as well as in adjacent unburnt areas. The results of the vegetation analyses, including a Detrended Correspondence Analysis, indicate that Pinus halepensis forest regeneration after fire resembles autosuccession. As regards the presence of woody species, there is a high percentage similarity on north (83%) and south (70%) facing slopes during the first year after fire vs. reference areas which is due, for example, to direct regeneration of the resprouting Quercus coccifera or seeders like Pinus halepensis or Fumana laevipes. However, if herbaceous species are included in the comparison, the similarity on north-facing sites decreases (to 53%) with the presence of additional species, mainly ruderals like Anagallis arvensis or Reseda phyteuma, and even woody species on the burnt plots. This effect indicates "enhanced autosuccession", which was not found on south-facing sites where overall species richness was very high irrespective of

  4. Assessment of the material properties of a fire damaged building

    OpenAIRE

    Oladipupo OLOMO; Olufikayo ADERINLEWO; Moses TANIMOLA; Silvana CROOPE

    2012-01-01

    This study identifies a process for assessing the material properties of a fire damaged building so as to determine whether the remains can be utilized in construction or be demolished. Physical and chemical analysis were carried out on concrete and steel samples taken from various elements of the building after thorough visual inspection of the entire building had been conducted. The physical (non-destructive) tests included the Schmidt hammer and ultrasonic pulse velocity tests on the concr...

  5. WRF-Fire: coupled weather-wildland fire modeling with the weather research and forecasting model

    Science.gov (United States)

    Janice L. Coen; Marques Cameron; John Michalakes; Edward G. Patton; Philip J. Riggan; Kara M. Yedinak

    2012-01-01

    A wildland fire behavior module (WRF-Fire) was integrated into the Weather Research and Forecasting (WRF) public domain numerical weather prediction model. The fire module is a surface fire behavior model that is two-way coupled with the atmospheric model. Near-surface winds from the atmospheric model are interpolated to a finer fire grid and used, with fuel properties...

  6. Fire safety requirements for electric cables and lines in deep coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Herms, C D

    1982-01-07

    In the case of a mine fire, an additional hazard from combustible cable material is likely to arise only in those few areas of the mine where special circumstances might help the fire to spread along the cables. It is more important to preserve the functional integrity of cables in the outbye roads which are affected by fire gases then at the actual seat of the fire. Mine cables with better fire-resistant properties should be made from materials which do not propagate fires, do not release burning drops, develop the lowest possible fume density and/or will permanently resist gas temperatures of 200 to 300/sup 0/C. Fire test specifications should be defined for such special cables, based on corresponding draft VDE directives. In proposing these measures the proviso is made then improvement in safety can be clearly demonstrated.

  7. Geometry-Of-Fire Tracking Algorithm for Direct-Fire Weapon Systems

    Science.gov (United States)

    2015-09-01

    this specific application. A scaled-down version for a fire team was created with XBee Pro radios, Arduino Uno microcontrollers, Raspberry Pi computers...constructed with XBee Pro radios, Arduino Uno microcontrollers, Raspberry Pi computers and ROS [5]. The XBee Pro radios and Arduino Uno microcontrollers

  8. Soil microbiological properties and enzymatic activities of long-term post-fire recovery in dry and semiarid Aleppo pine (Pinus halepensis M.) forest stands

    Science.gov (United States)

    Hedo, J.; Lucas-Borja, M. E.; Wic, C.; Andrés-Abellán, M.; de Las Heras, J.

    2015-02-01

    Wildfires affecting forest ecosystems and post-fire silvicultural treatments may cause considerable changes in soil properties. The capacity of different microbial groups to recolonise soil after disturbances is crucial for proper soil functioning. The aim of this work was to investigate some microbial soil properties and enzyme activities in semiarid and dry Aleppo pine (Pinus halepensis M.) forest stands. Different plots affected by a wildfire event 17 years ago without or with post-fire silvicultural treatments 5 years after the fire event were selected. A mature Aleppo pine stand, unaffected by wildfire and not thinned was used as a control. Physicochemical soil properties (soil texture, pH, carbonates, organic matter, electrical conductivity, total N and P), soil enzymes (urease, phosphatase, β-glucosidase and dehydrogenase activities), soil respiration and soil microbial biomass carbon were analysed in the selected forests areas and plots. The main finding was that long time after this fire event produces no differences in the microbiological soil properties and enzyme activities of soil after comparing burned and thinned, burned and not thinned, and mature plots. Moreover, significant site variation was generally seen in soil enzyme activities and microbiological parameters. We conclude that total vegetation recovery normalises post-fire soil microbial parameters, and that wildfire and post-fire silvicultural treatments are not significant factors affecting soil properties after 17 years.

  9. THE REACTION TO FIRE TEST FOR FIRE RETARDANT AND FOR COMBUSTIBLE MATERIAL

    Directory of Open Access Journals (Sweden)

    Adelaida FANFAROVÁ

    2016-12-01

    Full Text Available Currently the natural materials become popular building material for houses, buildings and recreational property. The risk of fires in residential timber construction or eco houses cannot be completely ruled out, therefore there is a need for proper and correct implementing preventive measures and application of all available solutions, which may reduce the risk of fire as far as possible, to slow down the combustion process, to protect the life of people, animals and also the building itself until arrival members of the Fire and Rescue Services. Fireproofing of combustible materials is a specific area of fire protection. For scientific research as well as for real-life practice, not only their structural and physical properties, but also fire-technical characteristics are really important. The present researchers mostly focus on fire-retardant treatment of wood that is why the authors of this contribution focused on a different combustible material. This research article presents the experimental testing and examination of the reaction to fire test of the selected thermal insulation of hemp fiber that was impregnated by the selected fire retardant in laboratory conditions.

  10. Linking hydraulic properties of fire-affected soils to infiltration and water repellency

    Science.gov (United States)

    Moody, John A.; Kinner, David A.; Úbeda, Xavier

    2009-12-01

    SummaryHeat from wildfires can produce a two-layer system composed of extremely dry soil covered by a layer of ash, which when subjected to rainfall, may produce extreme floods. To understand the soil physics controlling runoff for these initial conditions, we used a small, portable disk infiltrometer to measure two hydraulic properties: (1) near-saturated hydraulic conductivity, K f and (2) sorptivity, S( θ i), as a function of initial soil moisture content, θ i, ranging from extremely dry conditions ( θ i ash, reference soils, soils unaffected by fire, and fire-affected soils. Each has a different degrees of water repellency that influences K f and S( θ i). Values of K f ranged from 4.5 × 10 -3 to 53 × 10 -3 cm s -1 for ash; from 0.93 × 10 -3 to 130 × 10 -3 cm s -1 for reference soils; and from 0.86 × 10 -3 to 3.0 × 10 -3 cm s -1, for soil unaffected by fire, which had the lowest values of K f. Measurements indicated that S( θ i) could be represented by an empirical non-linear function of θ i with a sorptivity maximum of 0.18-0.20 cm s -0.5, between 0.03 and 0.08 cm 3 cm -3. This functional form differs from the monotonically decreasing non-linear functions often used to represent S( θ i) for rainfall-runoff modeling. The sorptivity maximum may represent the combined effects of gravity, capillarity, and adsorption in a transitional domain corresponding to extremely dry soil, and moreover, it may explain the observed non-linear behavior, and the critical soil-moisture threshold of water repellent soils. Laboratory measurements of K f and S( θ i) are the first for ash and fire-affected soil, but additional measurements are needed of these hydraulic properties for in situ fire-affected soils. They provide insight into water repellency behavior and infiltration under extremely dry conditions. Most importantly, they indicate how existing rainfall-runoff models can be modified to accommodate a possible two-layer system in extremely dry conditions. These

  11. Numerical modeling of the effects of fire-induced convection and fire-atmosphere interactions on wildfire spread and fire plume dynamics

    Science.gov (United States)

    Sun, Ruiyu

    It is possible due to present day computing power to produce a fluid dynamical physically-based numerical solution to wildfire behavior, at least in the research mode. This type of wildfire modeling affords a flexibility and produces details that are not available in either current operational wildfire behavior models or field experiments. However before using these models to study wildfire, validation is necessary, and model results need to be systematically and objectively analyzed and compared to real fires. Plume theory and data from the Meteotron experiment, which was specially designed to provide results from measurements for the theoretical study of a convective plume produced by a high heat source at the ground, are used here to evaluate the fire plume properties simulated by two numerical wildfire models, the Fire Dynamics Simulator or FDS, and the Clark coupled atmosphere-fire model. The study indicates that the FDS produces good agreement with the plume theory and the Meteotron results. The study also suggests that the coupled atmosphere-fire model, a less explicit and ideally less computationally demanding model than the FDS; can produce good agreement, but that the agreement is sensitive to the method of putting the energy released from the fire into the atmosphere. The WFDS (Wildfire and wildland-urban interface FDS), an extension of the FDS to the vegetative fuel, and the Australian grass fire experiments are used to evaluate and improve the UULES-wildfire coupled model. Despite the simple fire parameterization in the UULES-wildfire coupled model, the fireline is fairly well predicted in terms of both shape and location in the simulation of Australian grass fire experiment F19. Finally, the UULES-wildfire coupled model is used to examine how the turbulent flow in the atmospheric boundary layer (ABL) affects the growth of the grass fires. The model fires showed significant randomness in fire growth: Fire spread is not deterministic in the ABL, and a

  12. Effect of boron and phosphate compounds on physical, mechanical, and fire properties of wood-polypropylene composites

    Science.gov (United States)

    Nadir Ayrilmis; Turgay Akbulut; Turker Dundar; Robert H. White; Fatih Mengeloglu; Umit Buyuksari; Zeki Candan; Erkan Avci

    2012-01-01

    Physical, mechanical, and fire properties of the injection-molded wood flour/polypropylene composites incorporated with different contents of boron compounds; borax/boric acid and zinc borate, and phosphate compounds; mono and diammonium phosphates were investigated. The effect of the coupling agent content, maleic anhydride-grafted polypropylene, on the properties of...

  13. 36 CFR 1002.13 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fires. 1002.13 Section 1002... § 1002.13 Fires. (a) The following are prohibited: (1) Lighting or maintaining a fire, except in... or lanterns in violation of established restrictions. (3) Lighting, tending, or using a fire, stove...

  14. Antimicrobial properties of nest volatiles in red imported fire ants, Solenopsis invicta (hymenoptera: formicidae)

    Science.gov (United States)

    Wang, Lei; Elliott, Brad; Jin, Xixuan; Zeng, Ling; Chen, Jian

    2015-12-01

    The antimicrobial property of volatiles produced by red imported fire ants, Solenopsis invicta, against Beauveria bassiana, a common entomopathogenic fungus, was demonstrated. The germination rate of B. bassiana spores was significantly reduced after they were exposed to volatiles within an artificial ant nest. Since the air that contained the same level of O2 and CO2 as that in artificial fire ant nests did not suppress the germination rate of B. bassiana, the observed reduction of germination rate must be caused by the toxicity of nest volatiles. Nest fumigation may be an important component of the social immune system in S. invicta.

  15. Oxygen-Fired CO{sub 2} Recycle for Application to Direct CO{sub 2} Capture form Coal-Fired Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Gale

    2010-09-26

    The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

  16. Head direction cell activity in mice: robust directional signal depends on intact otolith organs

    Science.gov (United States)

    Yoder, Ryan M.; Taube, Jeffrey S.

    2009-01-01

    The head direction (HD) cell signal is a representation of an animal's perceived directional heading with respect to its environment. This signal appears to originate in the vestibular system, which includes the semicircular canals and otolith organs. Preliminary studies indicate the semicircular canals provide a necessary component of the HD signal, but involvement of otolithic information in the HD signal has not been tested. The present study was designed to determine the otolithic contribution to the HD signal, as well as to compare HD cell activity of mice to that of rats. HD cell activity in the anterodorsal thalamus was assessed in wild-type C57BL/6J and otoconia-deficient tilted mice during locomotion within a cylinder containing a prominent visual landmark. HD cell firing properties in C57BL/6J mice were generally similar to those in rats. However, in C57BL/6J mice, landmark rotation failed to demonstrate dominant control of the HD signal in 36% of the sessions. In darkness, directional firing became unstable during 42% of the sessions, but landmark control was not associated with HD signal stability in darkness. HD cells were identified in tilted mice, but directional firing properties were not as robust as those of C57BL/6J mice. Most HD cells in tilted mice were controlled by landmark rotation, but showed substantial signal degradation across trials. These results support current models that suggest otolithic information is involved in the perception of directional heading. Furthermore, compared to rats, the HD signal in mice appears to be less reliably anchored to prominent environmental cues. PMID:19176815

  17. Mechanical, thermal, and fire properties of biodegradable polylactide/boehmite alumina composites

    CSIR Research Space (South Africa)

    Das, K

    2013-05-01

    Full Text Available Industrial & Engineering Chemistry Research May 2013/ Vol. 52(18), pp 6083-6091 Mechanical, Thermal, and Fire Properties of Biodegradable Polylactide/Boehmite Alumina Composites Kunal Das,*,† Suprakas Sinha Ray,†,‡ Steve Chapple,§ and James Wesley...-Smith‡ †Department of Applied Chemistry, University of Johannesburg, Doornforntein 2028, Johannesburg, South Africa ‡DST/CSIR National Centre for Nano-Structured Materials, Council for Scientific and Industrial Research, Pretoria 0001, South Africa §Polymer...

  18. 36 CFR 331.15 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fires. 331.15 Section 331.15... INDIANA § 331.15 Fires. Open fires are prohibited unless confined to fireplaces, grills, or other facilities designed for this purpose as designated by the District Engineer. Fires shall not be left...

  19. A brush fire forensic case.

    Science.gov (United States)

    Rella, R; Sturaro, A; Parvoli, G; Ferrara, D; Casellato, U; Vadalà, G

    2005-01-01

    In Italy, every summer forest fires attract public attention due to the number of victims, the intensity of the fires, the areas devastated, the environmental damage and the loss of property. Excluding some fires by natural causes, other causes are related to the social, economic, and productive profile of the territory. The erroneous expectation is that wooded areas destroyed by fire can then be used for private interests. Often, a fire, started to clear a small area, can completely change the expected result, producing disaster, loss of property, destruction of entire forests and resident fauna, and kill innocent people. In this case report, the reconstruction of an arson scene, the analytical techniques and the results obtained are illustrated in this paper, with the aim of sharing with other research laboratories the current knowledge on forest fire.

  20. 36 CFR 261.5 - Fire.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Fire. 261.5 Section 261.5... Prohibitions § 261.5 Fire. The following are prohibited: (a) Carelessly or negligently throwing or placing any ignited substance or other substance that may cause a fire. (b) Firing any tracer bullet or incendiary...

  1. 36 CFR 261.52 - Fire.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Fire. 261.52 Section 261.52... in Areas Designated by Order § 261.52 Fire. When provided by an order, the following are prohibited: (a) Building, maintaining, attending or using a fire, campfire, or stove fire. (b) Using an explosive...

  2. Optimal control of gun recoil in direct fire using magnetorheological absorbers

    International Nuclear Information System (INIS)

    Singh, Harinder J; Wereley, Norman M

    2014-01-01

    Optimal control of a gun recoil absorber is investigated for minimizing recoil loads and maximizing rate of fire. A multi-objective optimization problem was formulated by considering the mechanical model of the recoil absorber employing a spring and a magnetorheological (MR) damper. The damper forces are predicted by evaluating pressure drops using a nonlinear Bingham-plastic model. The optimization methodology provides multiple optimal design configurations with a trade-off between recoil load minimization and increased rate of fire. The configurations with low or high recoil loads imply low or high rate of fire, respectively. The gun recoil absorber performance is also analyzed for perturbations in the firing forces. The adaptive control of the MR damper for varying gun firing forces provides a smooth operation by returning the recoil mass to its battery position (ready to reload and fire) without incurring an end-stop impact. Furthermore, constant load transmissions are observed with respect to the recoil stroke by implementing optimal control during the simulated firing events. (paper)

  3. Optimal control of gun recoil in direct fire using magnetorheological absorbers

    Science.gov (United States)

    Singh, Harinder J.; Wereley, Norman M.

    2014-05-01

    Optimal control of a gun recoil absorber is investigated for minimizing recoil loads and maximizing rate of fire. A multi-objective optimization problem was formulated by considering the mechanical model of the recoil absorber employing a spring and a magnetorheological (MR) damper. The damper forces are predicted by evaluating pressure drops using a nonlinear Bingham-plastic model. The optimization methodology provides multiple optimal design configurations with a trade-off between recoil load minimization and increased rate of fire. The configurations with low or high recoil loads imply low or high rate of fire, respectively. The gun recoil absorber performance is also analyzed for perturbations in the firing forces. The adaptive control of the MR damper for varying gun firing forces provides a smooth operation by returning the recoil mass to its battery position (ready to reload and fire) without incurring an end-stop impact. Furthermore, constant load transmissions are observed with respect to the recoil stroke by implementing optimal control during the simulated firing events.

  4. Subsurface Fire Hazards Technical Report

    International Nuclear Information System (INIS)

    Logan, R.C.

    1999-01-01

    The results from this report are preliminary and cannot be used as input into documents supporting procurement, fabrication, or construction. This technical report identifies fire hazards and proposes their mitigation for the subsurface repository fire protection system. The proposed mitigation establishes the minimum level of fire protection to meet NRC regulations, DOE fire protection orders, that ensure fire containment, adequate life safety provisions, and minimize property loss. Equipment requiring automatic fire suppression systems is identified. The subsurface fire hazards that are identified can be adequately mitigated

  5. Microwave dielectric properties of low-fired Li_2TiO_3–MgO ceramics for LTCC applications

    International Nuclear Information System (INIS)

    Ma, Jian-Li; Fu, Zhi-Fen; Liu, Peng; Wang, Bing; Li, Yang

    2016-01-01

    Graphical abstract: This figure gives the Q × f and τ_f of Li_2TiO_3–MgO ceramics sintered at various temperatures with different LiF contents. Addition of LiF enhanced the sinterability and optimized the microwave dielectric properties of Li_2TiO_3–MgO ceramics. The excellent microwave dielectric properties (ε_r = 15.8, Q × f = 64,500 GHz, and τ_f = −0.2 ppm/°C) of Li_2TiO_3–MgO ceramics sintered at 850 °C illustrated that LiF is a simple effective sintering aids for Li_2TiO_3–MgO ceramics. Such sample was compatible with Ag electrodes, suitable for the low-temperature co-fired ceramics (LTCC) applications. - Highlights: • Temperature stability of Li_2TiO_3 ceramics were improved by doping MgO. • The low-fired Li_2TiO_3–MgO ceramics are fabricated. • LiF liquid phase reduced sintering temperature of Li_2TiO_3–MgO ceramics to 850 °C. • The low-fired Li_2TiO_3–MgO ceramics possess well microwave dielectric properties. • The sample was compatible with Ag electrodes and suitable for LTCC applications. - Abstract: We fabricated the low-fired Li_2TiO_3–MgO ceramics doped with LiF by a conventional solid-state route, and investigated systematically their sintering characteristics, microstructures and microwave dielectric properties. The results showed that temperature stability of Li_2TiO_3 ceramics were improved by doping MgO. Well microwave dielectric properties for Li_2TiO_3–13 wt%MgO (LTM) ceramics with ε_r = 16.4, Q × f = 87,500 GHz, and τ_f = −1.2 ppm/°C were obtained at 1325 °C. Furthermore, addition of LiF enhanced the sinterability and optimized the microwave dielectric properties of LTM ceramics. A typically sample of LTM-4 wt%LiF ceramics with optimum dielectric properties (ε_r = 15.8, Q × f = 64,500 GHz, and τ_f = −0.2 ppm/°C) were achieved at 850 °C for 4 h. Such sample was compatible with Ag electrodes, suitable for the low-temperature co-fired ceramics (LTCC) applications.

  6. Fire safety engineering

    International Nuclear Information System (INIS)

    Smith, D.N.

    1989-01-01

    The periodic occurrence of large-scale, potentially disastrous industrial accidents involving fire in hazardous environments such as oilwell blowouts, petrochemical explosions and nuclear installations highlights the need for an integrated approach to fire safety engineering. Risk reduction 'by design' and rapid response are of equal importance in the saving of life and property in such situations. This volume of papers covers the subject thoroughly, touching on such topics as hazard analysis, safety design and testing, fire detection and control, and includes studies of fire hazard in the context of environment protection. (author)

  7. 36 CFR 34.6 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Fires. 34.6 Section 34.6... ADMINISTRATIVE SITE REGULATIONS § 34.6 Fires. (a) All wildland, vehicular or structural fires shall be reported... Fire Laws and Regulations are adopted as a part of this part. Violation of any of these regulations is...

  8. Slag processing system for direct coal-fired gas turbines

    Science.gov (United States)

    Pillsbury, Paul W.

    1990-01-01

    Direct coal-fired gas turbine systems and methods for their operation are provided by this invention. The gas turbine system includes a primary zone for burning coal in the presence of compressed air to produce hot combustion gases and debris, such as molten slag. The turbine system further includes a secondary combustion zone for the lean combustion of the hot combustion gases. The operation of the system is improved by the addition of a cyclone separator for removing debris from the hot combustion gases. The cyclone separator is disposed between the primary and secondary combustion zones and is in pressurized communication with these zones. In a novel aspect of the invention, the cyclone separator includes an integrally disposed impact separator for at least separating a portion of the molten slag from the hot combustion gases.

  9. Development of fly ash boards with thermal, acoustic and fire insulation properties.

    Science.gov (United States)

    Leiva, C; Arenas, C; Vilches, L F; Alonso-Fariñas, B; Rodriguez-Galán, M

    2015-12-01

    This paper presents an experimental analysis on a new board composed of gypsum and fly ashes from coal combustion, which are mutually compatible. Physical and mechanical properties, sound absorption coefficient, thermal properties and leaching test have been obtained. The mechanical properties showed similar values to other commercial products. As far as the acoustic insulation characteristics are concerned, sound absorption coefficients of 0.3 and 0.8 were found. The board presents a low thermal conductivity and a fire resistance higher than 50 min (for 4 cm of thickness). The leaching of trace elements was below the leaching limit values. These boards can be considered as suitable to be used in building applications as partitions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. New fire diurnal cycle characterizations to improve fire radiative energy assessments made from MODIS observations

    NARCIS (Netherlands)

    Andela, N.; Kaiser, J.; van der Werf, G.R.

    2015-01-01

    Accurate near real time fire emissions estimates are required for air quality forecasts. To date, most approaches are based on satellite-derived estimates of fire radiative power (FRP), which can be converted to fire radiative energy (FRE) which is directly related to fire emissions. Uncertainties

  11. Energy Analysis and Environmental Impacts of Hybrid Giant Napier (Pennisetum Hydridum) Direct-fired Power Generation in South China

    Science.gov (United States)

    Liao, Yanfen; Fang, Hailin; Zhang, Hengjin; Yu, Zhaosheng; Liu, Zhichao; Ma, Xiaoqian

    2017-05-01

    To meet with the demand of energy conservation and emission reduction policies, the method of life cycle assessment (LCA) was used to assess the feasibility of Hybrid Giant Napier (HGN) direct-fired power generation in this study. The entire life cycle is consisted of five stages (cultivation and harvesting, transportation, drying and comminuting, direct-fired power generation, constructing and decommissioning of biomass power plant). Analytical results revealed that to generate 10000kWh electricity, 10.925 t of customized HGN fuel (moisture content: 30 wt%) and 6659.430 MJ of energy were required. The total environmental impact potential was 0.927 PET2010 (person equivalents, targeted, in 2010) and the global warming (GW), acidification (AC), and nutrient (NE) emissions were 339.235 kg CO2-eq, 22.033 kg SO2-eq, and 25.486 kg NOx-eq respectively. The effect of AC was the most serious among all calculated category impacts. The energy requirements and environmental impacts were found to be sensitive to single yield, average transport distance, cutting frequency, and moisture content. The results indicated that HGN direct-fired power generation accorded well with Chinese energy planning; in addition, HGN proved to be a promising contribution to reducing non-renewable energy consumption and had encouraging prospects as a renewable energy plant.

  12. Installation of a direct fired Lanham bread baking system. A demonstration at Family Loaf Bakery Ltd. (Bristol)

    Energy Technology Data Exchange (ETDEWEB)

    1985-10-01

    The first installation in the UK of a direct-fired continuous conveyor oven capable of producing 8,500 loaves/hour has reduced energy costs at Family Loaf Bakery's Avonmouth plant by pound 66,680/year and resulted in net cost savings to the company of pound 59,680/year. This saving was achieved by using a direct-fired oven which had a low thermal mass and small oven openings. When baking identical products, a 30% saving in oven fuel was obtained using the new system compared to conventional systems. For this bakery, it is expected to save over 12,000 GJ/year. The bread baking system was of USA development and initial teething problems adapting to the more dense UK bread have now been overcome. (U.K.).

  13. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  14. Synthesis of knowledge of extreme fire behavior: volume I for fire managers

    Science.gov (United States)

    Paul A. Werth; Brian E. Potter; Craig B. Clements; Mark A. Finney; Scott L. Goodrick; Martin E. Alexander; Miguel G. Cruz; Jason A. Forthofer; Sara S. McAllister

    2011-01-01

    The National Wildfire Coordinating Group definition of extreme fire behavior (EFB) indicates a level of fire behavior characteristics that ordinarily precludes methods of direct control action. One or more of the following is usually involved: high rate of spread, prolific crowning/spotting, presence of fire whirls, and strong convection column. Predictability is...

  15. Fire impact and assessment of post-fire actions of a typical Mediterranean forest from SW Spain

    Science.gov (United States)

    Jiménez-González, Marco A.; María De la Rosa, José; Jiménez-Morillo, Nicasio T.; Zavala, Lorena M.; Knicker, Heike

    2015-04-01

    Wildfires may cause significant changes in soil physical and chemical properties. In addition, soil organic matter (SOM) content and chemical properties are usually affected by fire. Fire impacts may negatively affect soil health and quality, and induce or enhance runoff generation and, thereby, soil erosion risk and cause damages to the habitat of species. This fact is especially dramatic in Mediterranean ecosystems, where forest fires are a frequent phenomenon and restoration strategies are a key issue. The goals of this study are to determine: i) the immediate effects of fire on soil properties, including changes occurred in the quantity and quality of SOM and ii) the effect of post-fire actions on soil properties. In August 2012, a wildfire affected a forest area of approx. 90 ha in Montellano (Seville, SW Spain; longitude 37.00 °, latitude -5.56 °). This area is dominated by pines (Pinus pinaster and Pinus halepensis), and eucalypts (Eucaliptus globulus) with a Mediterranean climate. Dominant soil types are Rendzic Leptosols and Calcaric Haplic Regosols. It is a poorly limestone-developed soil (usually swallower than 25 cm). Four soil subsamples were collected 1 month and 25 months after fire within an area of approximately 200 m2. Subsamples were mixed together, homogenized, air-dried, crushed and sieved (2 mm). One control sample was collected in an adjacent area. The litter layer was removed by hand and studied separately. Branches, stems, bushes and plant residues on the fire-affected area were removed 16 months after the fire using heavy machinery as part of the post-fire management. The present research focuses on the study of the elemental composition (C, H and N) and physical properties (pH, water holding capacity, electrical conductivity) of bulk soil samples, and on the spectroscopic analysis (FT-IR, 13C NMR) and analytical pyrolysis data obtained from bulk the oils and from the humic acid fraction. immediate effects of fire, including the charring

  16. Exploring functional relationships between post-fire soil water repellency, soil structure and physico-chemical properties

    Science.gov (United States)

    Quarfeld, Jamie; Brook, Anna; Keestra, Saskia; Wittenberg, Lea

    2016-04-01

    Soil water repellency (WR) and aggregate stability (AS) are two soil properties that are typically modified after burning and impose significant influence on subsequent hydrological and geomorphological dynamics. The response of AS and soil WR to fire depends upon how fire has influenced other key soil properties (e.g. soil OM, mineralogy). Meanwhile, routine thinning of trees and woody vegetation may alter soil properties (e.g. structure and porosity, wettability) by use of heavy machinery and species selection. The study area is situated along a north-facing slope of Mount Carmel national park (Israel). The selected sites are presented as a continuum of management intensity and fire histories. To date, the natural baseline of soil WR has yet to be thoroughly assessed and must be investigated alongside associated soil aggregating parameters in order to understand its overall impact. This study examines (i) the natural baseline of soil WR and physical properties compared to those of disturbed sites in the immediate (controlled burn) and long-term (10-years), and (ii) the interactions of soil properties with different control factors (management, surface cover, seasonal-temporal, burn temperature, soil organic carbon (OC) and mineralogy) in Mediterranean calcareous soils. Analysis of surface soil samples before and after destruction of WR by heating (200-600°C) was implemented using a combination of traditional methods and infrared (IR) spectroscopy. Management and surface cover type conditioned the wettability, soil structure and porosity of soils in the field, although this largely did not affect the heat-induced changes observed in the lab. A positive correlation was observed along an increasing temperature gradient, with relative maxima of MWD and BD reached by most soils at the threshold of 400-500°C. Preliminary analyses of soil OC (MIR) and mineralogical composition (VIS-NIR) support existing research regarding: (i) the importance of soil OC quality and

  17. Characterisation of solid recovered fuels for direct co-firing in large-scale PF power plants

    Energy Technology Data Exchange (ETDEWEB)

    Dunnu, Gregory

    2013-04-01

    Solid Recovered Fuels are solid fuels prepared from high calorific fractions of non-hazardous waste materials intended to be co-fired in coal power plants and industrial furnaces (CEN/TC 343). They are composed of a variety of materials of which some, although recyclable in theory, may be in a form that makes their recycling an unsound option. The SRF with a typical size range of 3 mm through 25 mm are to be directly co-fired in an existing pulverised coal power plant. In comparison to pulverised coal, the particle size distribution of the SRF is of several magnitudes higher, resulting in a different burnout behaviour. Size reduction of the SRF to a fraction similar to coal is not economically feasible. The aim here is, therefore, the direct co-firing of the solid recovered fuels in the boilers without any further size reduction. This approach, however, bears the risk of incomplete combustion if the injection points of the solid recovered fuels are not optimally selected. Accordingly, the prediction of the burner levels, at which the solid recovered fuels should be injected and whether or not a complete combustion will be achieved under full load condition, is the primary objective of this dissertation. In this research work, laboratory experiments have been conducted to forecast the success of co-firing the SRF in a commercial pulverised coal power plant. It involves the analyses of the fuel and its intermediate chars generated at conditions comparable to boiler conditions to determine some characteristic parameters, namely the burnout time, the aerodynamic lift velocity, the drag coefficient and the apparent densities. The data gathered from the laboratory experiments are transferred to boiler conditions to determine the particle trajectories and the maximum distance likely to travel before they are completely converted in the boiler. Different scenarios are examined and based on the results the best boiler injection points are predicted. Furthermore, an on

  18. Fire Source Accessibility of Water Mist Fire Suppression Improvement through Flow Method Control

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jun Ho; Kim, Hyeong Taek; Kim, Yun Jung; Park, Mun Hee [KHNP CRI, Daejeon (Korea, Republic of)

    2013-10-15

    Recently, nuclear power plants set CO{sub 2} fire suppression system. However it is hard to establish and to maintain and it also has difficulties performing function test. Therefore, it needs to develop a new fire suppression system to replace the existing CO{sub 2} fire suppression systems in nuclear power plant. In fact, already, there exist alternatives - gas fire suppression system or clean fire extinguishing agent, but it is hard to apply because it requires a highly complicated plan. However, water mist fire suppression system which has both water system and gas system uses small amount of water and droplet, so it is excellent at oxygen displacement and more suitable for nuclear power plant because it can avoid second damage caused by fire fighting water. This paper explains about enclosure effect of water mist fire suppression. And it suggests a study direction about water mist fire source approach improvement and enclosure effect improvement, using flow method control of ventilation system. Water mist fire suppression can be influenced by various variable. And flow and direction of ventilation system are important variable. Expectations of the plan for more fire source ventilation system is as in the following. It enhances enclosure effects of water mists, so it improves extinguish performance. Also the same effect as a inert gas injection causes can be achieved. Lastly, it is considered that combustible accessibility of water mists will increase because of descending air currents.

  19. Ash transformation in suspension fired boilers co-firing coal and straw

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Jensen, Peter Arendt; Jensen, Anker Degn

    In this literature report is provided a status for the present knowledge level on ash properties when co-firing coal and biomass. The fly ash formed in boilers using co-firing of coal and straw do have a large influence on ash deposit formation, boiler corrosion, fly ash utilization and operation...

  20. Wild fire aerosol optical properties measured by lidar at Haifa, Israel

    Science.gov (United States)

    Heese, Birgit; Hofer, Julian; Baars, Holger; Engelmann, Ronny; Althausen, Dietrich; Schechner, Yoav Y.

    2018-04-01

    Optical properties of fresh biomass burning aerosol were measured by lidar during the wild fires in Israel in November 2016. A single-wavelength lidar Polly was operated at the Technion Campus at Haifa. The detector with originally two channels at 532 and 607 nm was recently upgraded with a cross- and a co-polarised channel at 532 nm, and a rotational Raman channel at 530.2 nm. Preliminary results show high particle depolarisation ratios probably caused by soil dust and large fly-ash particles.

  1. Bistable firing properties of soleus motor units in unrestrained rats

    DEFF Research Database (Denmark)

    EKEN, T.; KIEHN, O.

    1989-01-01

    of the motoneuron pool by stimulation of la afferents, or inhibition by stimulation of skin afferents. The shifts were not related to gross limb movements. This phenomenon is referred to as a bistable firing pattern. Bistable firing also occurred spontaneously during quiet standing. Typically the firing frequency...... was unchanged or only phasically influenced. These results demonstrate for the first time a bistable firing pattern during postural activity in the intact animal. The firing pattern closely resembles the bistable behaviour described in spinal motoneurons in reduced preparations, where it is due to the presence...... of a plateau potential. This suggests that the bistable firing is unexplained by plateau potentials also in the intact animal....

  2. The effect of simulating porcelain firing on the elemental composition, microstructure, and mechanical properties of electroformed gold restorations

    Directory of Open Access Journals (Sweden)

    Youssef S. Al Jabbari

    2016-09-01

    Conclusion: Although microstructure and elemental composition of electroformed Au crowns remain unchanged, the mechanical properties are significantly affected by the thermal treatment of porcelain firing.

  3. Cinema Fire Modelling by FDS

    International Nuclear Information System (INIS)

    Glasa, J; Valasek, L; Weisenpacher, P; Halada, L

    2013-01-01

    Recent advances in computer fluid dynamics (CFD) and rapid increase of computational power of current computers have led to the development of CFD models capable to describe fire in complex geometries incorporating a wide variety of physical phenomena related to fire. In this paper, we demonstrate the use of Fire Dynamics Simulator (FDS) for cinema fire modelling. FDS is an advanced CFD system intended for simulation of the fire and smoke spread and prediction of thermal flows, toxic substances concentrations and other relevant parameters of fire. The course of fire in a cinema hall is described focusing on related safety risks. Fire properties of flammable materials used in the simulation were determined by laboratory measurements and validated by fire tests and computer simulations

  4. Cinema Fire Modelling by FDS

    Science.gov (United States)

    Glasa, J.; Valasek, L.; Weisenpacher, P.; Halada, L.

    2013-02-01

    Recent advances in computer fluid dynamics (CFD) and rapid increase of computational power of current computers have led to the development of CFD models capable to describe fire in complex geometries incorporating a wide variety of physical phenomena related to fire. In this paper, we demonstrate the use of Fire Dynamics Simulator (FDS) for cinema fire modelling. FDS is an advanced CFD system intended for simulation of the fire and smoke spread and prediction of thermal flows, toxic substances concentrations and other relevant parameters of fire. The course of fire in a cinema hall is described focusing on related safety risks. Fire properties of flammable materials used in the simulation were determined by laboratory measurements and validated by fire tests and computer simulations

  5. 36 CFR 327.10 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fires. 327.10 Section 327.10... Fires. (a) Gasoline and other fuels, except that which is contained in storage tanks of vehicles... onto or stored on the project without written permission of the District Commander. (b) Fires shall be...

  6. Human Nav1.8: enhanced persistent and ramp currents contribute to distinct firing properties of human DRG neurons

    Science.gov (United States)

    Han, Chongyang; Estacion, Mark; Huang, Jianying; Vasylyev, Dymtro; Zhao, Peng; Dib-Hajj, Sulayman D.

    2015-01-01

    Although species-specific differences in ion channel properties are well-documented, little has been known about the properties of the human Nav1.8 channel, an important contributor to pain signaling. Here we show, using techniques that include voltage clamp, current clamp, and dynamic clamp in dorsal root ganglion (DRG) neurons, that human Nav1.8 channels display slower inactivation kinetics and produce larger persistent current and ramp current than previously reported in other species. DRG neurons expressing human Nav1.8 channels unexpectedly produce significantly longer-lasting action potentials, including action potentials with half-widths in some cells >10 ms, and increased firing frequency compared with the narrower and usually single action potentials generated by DRG neurons expressing rat Nav1.8 channels. We also show that native human DRG neurons recapitulate these properties of Nav1.8 current and the long-lasting action potentials. Together, our results demonstrate strikingly distinct properties of human Nav1.8, which contribute to the firing properties of human DRG neurons. PMID:25787950

  7. Fire Models and Design Fires

    DEFF Research Database (Denmark)

    Poulsen, Annemarie

    The aim of this project is to perform an experimental study on the influence of the thermal feedback on the burning behavior of well ventilated pre-flashover fires. For the purpose an experimental method has been developed. Here the same identical objects are tested under free burn conditions...... carried out by Carleton University and NRC-IRC performed on seven different types of fire loads representing commercial premises, comprise the tests used for the study. The results show that for some of the room test the heat release rate increased due to thermal feedback compared to free burn for a pre......-flashover fire. Two phenomena were observed, that relate well to theory was found. In an incipient phase the heat release rate rose with the temperature of the smoke layer/enclosure boundaries. This increase was also found to depend on the flammability properties of the burning object. The results also...

  8. Fire exposed aluminium structures

    NARCIS (Netherlands)

    Maljaars, J.; Fellinger, J.E.J.; Soetens, F.

    2005-01-01

    Material properties and mechanical response models for fire design of steel structures are based on extensive research and experience. Contrarily, the behaviour of aluminium load bearing structures exposed to fire is relatively unexplored. This article gives an overview of physical and mechanical

  9. Wildland Fire Management Plan for Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Schwager, K.; Green, T. M.

    2014-01-01

    The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

  10. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Schwager, K.; Green, T. M.

    2014-10-01

    The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

  11. Behavior of prestressing steels after fire

    OpenAIRE

    Atienza Riera, José Miguel; Elices Calafat, Manuel

    2008-01-01

    Even if a fire does not give rise to apparent damage in a prestressed structure, mechanical properties of materials as well as load distribution can be affected. A verification of residual load bearing capacity after fire is necessary to determine if the structure can be maintained in use. Mechanical properties of structural steels at high temperatures have been extensively studied. However, no attention has been paid to the behavior of steel wires after fire. This paper seeks to give a simpl...

  12. 36 CFR 2.13 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Fires. 2.13 Section 2.13... PROTECTION, PUBLIC USE AND RECREATION § 2.13 Fires. (a) The following are prohibited: (1) Lighting or maintaining a fire, except in designated areas or receptacles and under conditions that may be established by...

  13. Firing probability and mean firing rates of human muscle vasoconstrictor neurones are elevated during chronic asphyxia

    DEFF Research Database (Denmark)

    Ashley, Cynthia; Burton, Danielle; Sverrisdottir, Yrsa B

    2010-01-01

    in the obstructive sleep apnoea syndrome (OSAS) is associated with an increase in firing probability and mean firing rate, and an increase in multiple within-burst firing. Here we characterize the firing properties of muscle vasoconstrictor neurones in patients with chronic obstructive pulmonary disease (COPD), who...... are chronically asphyxic. We tested the hypothesis that this elevated chemical drive would shift the firing pattern from that seen in healthy subjects to that seen in OSAS. The mean firing probability (52%) and mean firing rate (0.92 Hz) of 17 muscle vasoconstrictor neurones recorded in COPD were comparable...

  14. Directed networks, allocation properties and hierarchy formation

    NARCIS (Netherlands)

    Slikker, M.; Gilles, R.P.; Norde, H.W.; Tijs, S.H.

    2005-01-01

    We investigate properties for allocation rules on directed communication networks and the formation of such networks under these payoff properties. We study allocation rules satisfying two appealing properties, Component Efficiency (CE) and the Hierarchical Payoff Property (HPP). We show that such

  15. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90 Section 102-80.90 Public Contracts and Property Management Federal Property Management Regulations System...

  16. Fabrication of Robust Superhydrophobic Bamboo Based on ZnO Nanosheet Networks with Improved Water-, UV-, and Fire-Resistant Properties

    Directory of Open Access Journals (Sweden)

    Jingpeng Li

    2015-01-01

    Full Text Available Bamboo with water-resistant, UV-resistant, and fire-resistant properties was desirable in modern society. In this paper, the original bamboo was firstly treated with ZnO sol and then hydrothermally the ZnO nanosheet networks grow onto the bamboo surface and subsequently modified with fluoroalkyl silane (FAS-17. The FAS-17 treated bamboo substrate exhibited not only robust superhydrophobicity with a high contact angle of 161° but also stable repellency towards simulated acid rain (pH = 3 with a contact angle of 152°. Except for its robust superhydrophobicity, such a bamboo also presents superior water-resistant, UV-resistant, and fire-resistant properties.

  17. A novel direct-fired porous-medium boiler

    Science.gov (United States)

    Prasartkaew, Boonrit

    2018-01-01

    Nowadays, power and heat generation systems pay an important role in all economic sectors. These systems are mainly based on combustion reaction and operated under the second law of thermodynamics. A conventional boilers, a main component of heat and power generators, have thermal efficiency in the range of 70 to 85%, mainly owing to they have flue gas heat loss. This paper proposes a novel type of boiler, called a Direct-fired Porous-medium Boiler (DPB). Due to being operated without flue gas heat loss, its thermal efficiency cloud be approximately close to 100%. The steam produced from the proposed boiler; however, is not pure water steam. It is the composite gases of steam and combustion-product-gases. This paper aims at presenting the working concept and reporting the experimental results on the performance of the proposed boiler. The experiments of various operating parameters were performed and collected data were used for the performance analysis. The experimental results demonstrated that the proposed boiler can be operated as well as the conceptual design and then it is promising. It can be possibly further developed to be a high efficiency boiler by means of reducing or suppressing the surface heat loss with better insulator and/or refractory lined.

  18. Characterizing context-dependent differential firing activity in the hippocampus and entorhinal cortex.

    Science.gov (United States)

    Prerau, Michael J; Lipton, Paul A; Eichenbaum, Howard B; Eden, Uri T

    2014-04-01

    The rat hippocampus and entorhinal cortex have been shown to possess neurons with place fields that modulate their firing properties under different behavioral contexts. Such context-dependent changes in neural activity are commonly studied through electrophysiological experiments in which a rat performs a continuous spatial alternation task on a T-maze. Previous research has analyzed context-based differential firing during this task by describing differences in the mean firing activity between left-turn and right-turn experimental trials. In this article, we develop qualitative and quantitative methods to characterize and compare changes in trial-to-trial firing rate variability for sets of experimental contexts. We apply these methods to cells in the CA1 region of hippocampus and in the dorsocaudal medial entorhinal cortex (dcMEC), characterizing the context-dependent differences in spiking activity during spatial alternation. We identify a subset of cells with context-dependent changes in firing rate variability. Additionally, we show that dcMEC populations encode turn direction uniformly throughout the T-maze stem, whereas CA1 populations encode context at major waypoints in the spatial trajectory. Our results suggest scenarios in which individual cells that sparsely provide information on turn direction might combine in the aggregate to produce a robust population encoding. Copyright © 2014 Wiley Periodicals, Inc.

  19. Advanced materials for alternative fuel capable directly fired heat engines

    Energy Technology Data Exchange (ETDEWEB)

    Fairbanks, J.W.; Stringer, J. (eds.)

    1979-12-01

    The first conference on advanced materials for alternative fuel capable directly fired heat engines was held at the Maine Maritime Academy, Castine, Maine. It was sponsored by the US Department of Energy, (Assistant Secretary for Fossil Energy) and the Electric Power Research Institute, (Division of Fossil Fuel and Advanced Systems). Forty-four papers from the proceedings have been entered into EDB and ERA and one also into EAPA; three had been entered previously from other sources. The papers are concerned with US DOE research programs in this area, coal gasification, coal liquefaction, gas turbines, fluidized-bed combustion and the materials used in these processes or equipments. The materials papers involve alloys, ceramics, coatings, cladding, etc., and the fabrication and materials listing of such materials and studies involving corrosion, erosion, deposition, etc. (LTN)

  20. FIRE HAZARDS ANALYSIS - BUSTED BUTTE

    International Nuclear Information System (INIS)

    Longwell, R.; Keifer, J.; Goodin, S.

    2001-01-01

    The purpose of this fire hazards analysis (FHA) is to assess the risk from fire within individual fire areas at the Busted Butte Test Facility and to ascertain whether the DOE fire safety objectives are met. The objective, identified in DOE Order 420.1, Section 4.2, is to establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire related event. (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees. (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards. (4) Property losses from a fire and related events exceeding limits established by DOE. Critical process controls and safety class systems being damaged as a result of a fire and related events

  1. From the study of fire effects on individual soil properties to the development of soil quality indices. 1. The pioneer research

    Science.gov (United States)

    Mataix-Solera, Jorge; Zornoza, Raúl

    2013-04-01

    Although forest fires must be considered as a natural factor in Mediterranean ecosystems, the modification of its natural regime during last five decades has thansformed them in an environmental problem. In the Valencia region (E Spain) 1994 was the worst year in the history affecting more than 120,000 hectares. I started my Ph.D that year by studying the effects of fires in soil properties. The availability to be able to analyse a great set of different types of soil properties in the laboratories of University of Alicante allowed me to explore how fires could affect physical, chemical and micobiological soil properties. After years studying different soil properties, finding that several factors are involved, including: fire intensity and severity, vegetation, soil type, climate conditions, etc. (Mataix-Solera and Doerr, 2004; Mataix-Solera et al., 2008, 2011) my research as Ph-D supervisor has been focussed to investigate more in depth some selected properties, such as aggregate stability and water repellency (Arcenegui et al., 2007, 2008). But one of the main problems in the studies conducted with samples affected by wildfires is that for the evaluation of the fire impact in the soil it is necessary to have control (unburned) soil samples from a similar non-affected near area. The existing spatial variability under field conditions does not allow having comparable samples in some acses to develop a correct assessment. With this idea in mind one of my Ph.D researcher (R. Zornoza) dedicated his thesis to develope soil quality indices capable to assess the impact of soil perturbations without comparing groups of samples, but evaluating the equilibrium among different soil properties within each soil sample (Zornoza et al., 2007, 2008). Key words: wildfire, Mediterranean soils, soil degradation, wàter repellency, aggregate stability References: Arcenegui, V., Mataix-Solera, J., Guerrero, C., Zornoza, R., Mayoral, A.M., Morales, J., 2007. Factors controlling the

  2. Visual Orientation and Directional Selectivity through Thalamic Synchrony

    Science.gov (United States)

    Stanley, Garrett B.; Jin, Jianzhong; Wang, Yushi; Desbordes, Gaëlle; Wang, Qi; Black, Michael J.; Alonso, Jose-Manuel

    2012-01-01

    Thalamic neurons respond to visual scenes by generating synchronous spike trains on the timescale of 10 – 20 ms that are very effective at driving cortical targets. Here we demonstrate that this synchronous activity contains unexpectedly rich information about fundamental properties of visual stimuli. We report that the occurrence of synchronous firing of cat thalamic cells with highly overlapping receptive fields is strongly sensitive to the orientation and the direction of motion of the visual stimulus. We show that this stimulus selectivity is robust, remaining relatively unchanged under different contrasts and temporal frequencies (stimulus velocities). A computational analysis based on an integrate-and-fire model of the direct thalamic input to a layer 4 cortical cell reveals a strong correlation between the degree of thalamic synchrony and the nonlinear relationship between cortical membrane potential and the resultant firing rate. Together, these findings suggest a novel population code in the synchronous firing of neurons in the early visual pathway that could serve as the substrate for establishing cortical representations of the visual scene. PMID:22745507

  3. Change of mechanical properties of Norway Spruce wood due to degradation caused by fire retardants

    Czech Academy of Sciences Publication Activity Database

    Kloiber, Michal; Frankl, Jiří; Drdácký, Miloš; Kučerová, I.; Tippner, J.; Bryscejn, Jan

    2010-01-01

    Roč. 55, č. 4 (2010), s. 23-38 ISSN 1336-4561 Grant - others:GAČR(CZ) GA103/07/1091 Program:GA Institutional research plan: CEZ:AV0Z20710524 Keywords : wood degradation * fire retardant * mechanical properties * tensile strength * hardness Subject RIV: JN - Civil Engineering Impact factor: 0.284, year: 2010

  4. Human Na(v)1.8: enhanced persistent and ramp currents contribute to distinct firing properties of human DRG neurons.

    Science.gov (United States)

    Han, Chongyang; Estacion, Mark; Huang, Jianying; Vasylyev, Dymtro; Zhao, Peng; Dib-Hajj, Sulayman D; Waxman, Stephen G

    2015-05-01

    Although species-specific differences in ion channel properties are well-documented, little has been known about the properties of the human Nav1.8 channel, an important contributor to pain signaling. Here we show, using techniques that include voltage clamp, current clamp, and dynamic clamp in dorsal root ganglion (DRG) neurons, that human Na(v)1.8 channels display slower inactivation kinetics and produce larger persistent current and ramp current than previously reported in other species. DRG neurons expressing human Na(v)1.8 channels unexpectedly produce significantly longer-lasting action potentials, including action potentials with half-widths in some cells >10 ms, and increased firing frequency compared with the narrower and usually single action potentials generated by DRG neurons expressing rat Na(v)1.8 channels. We also show that native human DRG neurons recapitulate these properties of Na(v)1.8 current and the long-lasting action potentials. Together, our results demonstrate strikingly distinct properties of human Na(v)1.8, which contribute to the firing properties of human DRG neurons.

  5. Fire metrology: Current and future directions in physics-based measurements

    Science.gov (United States)

    Robert L. Kremens; Alistair M.S. Smith; Matthew B. Dickinson

    2010-01-01

    The robust evaluation of fire impacts on the biota, soil, and atmosphere requires measurement and analysis methods that can characterize combustion processes across a range of temporal and spatial scales. Numerous challenges are apparent in the literature. These challenges have led to novel research to quantify the 1) structure and heterogeneity of the pre-fire...

  6. Fire-regime variability impacts forest carbon dynamics for centuries to millennia

    Science.gov (United States)

    Hudiburg, Tara W.; Higuera, Philip E.; Hicke, Jeffrey A.

    2017-08-01

    Wildfire is a dominant disturbance agent in forest ecosystems, shaping important biogeochemical processes including net carbon (C) balance. Long-term monitoring and chronosequence studies highlight a resilience of biogeochemical properties to large, stand-replacing, high-severity fire events. In contrast, the consequences of repeated fires or temporal variability in a fire regime (e.g., the characteristic timing or severity of fire) are largely unknown, yet theory suggests that such variability could strongly influence forest C trajectories (i.e., future states or directions) for millennia. Here we combine a 4500-year paleoecological record of fire activity with ecosystem modeling to investigate how fire-regime variability impacts soil C and net ecosystem carbon balance. We found that C trajectories in a paleo-informed scenario differed significantly from an equilibrium scenario (with a constant fire return interval), largely due to variability in the timing and severity of past fires. Paleo-informed scenarios contained multi-century periods of positive and negative net ecosystem C balance, with magnitudes significantly larger than observed under the equilibrium scenario. Further, this variability created legacies in soil C trajectories that lasted for millennia. Our results imply that fire-regime variability is a major driver of C trajectories in stand-replacing fire regimes. Predicting carbon balance in these systems, therefore, will depend strongly on the ability of ecosystem models to represent a realistic range of fire-regime variability over the past several centuries to millennia.

  7. An Early Fire Detection Algorithm Using IP Cameras

    Directory of Open Access Journals (Sweden)

    Hector Perez-Meana

    2012-05-01

    Full Text Available The presence of smoke is the first symptom of fire; therefore to achieve early fire detection, accurate and quick estimation of the presence of smoke is very important. In this paper we propose an algorithm to detect the presence of smoke using video sequences captured by Internet Protocol (IP cameras, in which important features of smoke, such as color, motion and growth properties are employed. For an efficient smoke detection in the IP camera platform, a detection algorithm must operate directly in the Discrete Cosine Transform (DCT domain to reduce computational cost, avoiding a complete decoding process required for algorithms that operate in spatial domain. In the proposed algorithm the DCT Inter-transformation technique is used to increase the detection accuracy without inverse DCT operation. In the proposed scheme, firstly the candidate smoke regions are estimated using motion and color smoke properties; next using morphological operations the noise is reduced. Finally the growth properties of the candidate smoke regions are furthermore analyzed through time using the connected component labeling technique. Evaluation results show that a feasible smoke detection method with false negative and false positive error rates approximately equal to 4% and 2%, respectively, is obtained.

  8. Can listed property shares be a surrogate for direct property investment behaviour?

    Directory of Open Access Journals (Sweden)

    Douw Boshoff

    2012-03-01

    Full Text Available The listed property sector in South Africa has grown to a size which could be considered to be a good representation of the income producing property market in general. Stock market listed property investment funds offer the opportunity to compare indirect property investment to direct property investment, which could bridge the gap between irrational investment behaviour and intrinsic asset values. This study investigates the relationship between listed property share prices and the property values in listed property funds. The share prices are correlated with various factors, such as the accounting ratios of the companies, the financial statements of the companies and general economic variables. The outcome of the study is an explanation of the behaviour of listed property shares, and its relationship to the direct property market and the general economy. This would assist in the explanation of market behaviour and provides the opportunity to more accurately predict portfolio asset values, which might be used in the valuation of individual real estate assets.

  9. 46 CFR 132.120 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... deck. (g) No branch line may be directly connected to the fire main except for fighting fires or for... main system, it must lead from a discharge manifold near the fire pump. (i) The total cross-sectional... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 132.120 Section 132.120 Shipping COAST GUARD...

  10. Corrosion and Materials Performance in biomass fired and co-fired power plants

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Larsen, OH; Biede, O

    2003-01-01

    not previously encountered in coal-fired power plants. The type of corrosion attack can be directly ascribed to the composition of the deposit and the metal surface temperature. In woodchip boilers, a similar corrosion rate and corrosion mechanism has on some occasions been observed. Co-firing of straw (10...... and 20% energy basis) with coal has shown corrosion rates lower than those in straw-fired plants. With both 10 and 20% straw, no chlorine corrosion was seen. This paper will describe the results from in situ investigations undertaken in Denmark on high temperature corrosion in biomass fired plants....... Results from 100% straw-firing, woodchip and co-firing of straw with coal will be reported. The corrosion mechanisms observed are summarized and the corrosion rates for 18-8 type stainless steels are compared....

  11. 29 CFR 1915.505 - Fire response.

    Science.gov (United States)

    2010-07-01

    ... accomplished; (3) Set up an incident management system to coordinate and direct fire response functions...-2000 Standard on Protective Ensemble for Structural Fire Fighting (incorporated by reference, see... for Proximity Fire Fighting (incorporated by reference, see § 1915.5). (6) Personal Alert Safety...

  12. A Framework for Assessment of Intentional Fires

    Directory of Open Access Journals (Sweden)

    Iraj Mohammadfam

    2014-04-01

    Full Text Available Background & Objectives : It is not possible to live without using fire. However, fire could destruct human properties in a short time. One of the most important types of fire is intentional fire. This type of fire has become a great problem for insurance companies, fire departments, industries, government and business in the recent years. This study aimed to provide a framework for risk assessment of intentional fires . Methods: In the present study, risk assessment and management model for protecting critical properties and security vulnerability assessment model were used to develop a comprehensive framework for risk assessment of intentional fires. The framework was examined in an automotive industry . Results : The designed framework contained five steps as 1 asset inventory and prioritizing them according to their importance, 2 invasion assessment, 3 vulnerability assessment, 4 risk assessment and design and 5 implementation and evaluating the effectiveness of corrective/preventive actions. Thirty different scenarios for intentional fires were identified by implementing the designed framework in an automotive company, and then the associated risk of each scenario was quantitatively determined. Conclusion : Compared to seven models, the proposed framework represents its comprehension. Development of safety and security standards and a central security information bank to reduce security risks, including the risk of intentional fires is recommended .

  13. Fire weather and large fire potential in the northern Sierra Nevada

    Science.gov (United States)

    Brandon M. Collins

    2014-01-01

    Fuels, weather, and topography all contribute to observed fire behavior. Of these, weather is not only the most dynamic factor, it is the most likely to be directly influenced by climate change. In this study 40 years of daily fire weather observations from five weather stations across the northern Sierra Nevada were analyzed to investigate potential changes or trends...

  14. EFFICIENCY OF FIRE-FIGHTING PROTECTION OBJECTS IN PROVISION OF FIRE SAFETY AT INDUSTRIAL ENTERPRISES

    Directory of Open Access Journals (Sweden)

    A. V. Zhovna

    2008-01-01

    Full Text Available The paper gives an analysis of economic results pertaining to organization of a system for fire-fighting protection of industrial enterprises in theRepublicofBelarus. Statistical data on operational conditions of technical means of fire-fighting protection, particularly, automatic systems for detection and extinguishing of fires, systems of internal fire-fighting water-supply.  Requirements and provisions  of normative and technical documents are thoroughly studied. Observance of these documents is to ensure the required level of  fire safety. On the basis of the obtained results concerning  economic analysis of efficiency optimization directions are defined for selection of technical means of fire-fighting protection at objects of industrial purpose.

  15. Fire intensity impacts on post-fire temperate coniferous forest net primary productivity

    Science.gov (United States)

    Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.

    2018-02-01

    Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.

  16. Effect of post-fire salvage logging treatments on micobiological properties of two different soils in the Povince of Alicante.

    Science.gov (United States)

    Arcenegui, Victoria

    2017-04-01

    It is well known that the natural wildfire regime in Mediterranean forests is greatly disturbed by human activities. Fire can induce temporal or permanent changes in the soil (see Certini, 2005) and can retard or compromise the recovery of the ecosystem afterwards. Changes in soil properties and the impact on soil functions depend mainly on the severity of the fires (Neary et al., 1999) and type of soil and weather during and after burning (Robichaud & Hungerford, 2000). Post-fire management can have an additional impact on the ecosystem; in some cases, even more severe than the fire. Post-fire salvage logging treatments are very frequently but its ecological impact is uncertain. Mainly because there are so many variables at play. A research has been done in "Sierra de Mariola Natural Park" in Alcoi (M) and ''Cabo de San Antonio'' in Javea (J), both in the Province of Alicante (E Spain). A big forest fire (>500 has) occurred in July 2012 and in September 2014 respectively. After fire, salvage logging (SL) treatment were done. In the first area (M), with a soil classified as Typic Xerorthent, extraction of the burned wood using heavy machinery was applied. In contrast, in the second area (J), a Rhodoxeralf soil, not heavy machinery was used. Plots for monitoring this effect were installed in both areas and in a similar nearby area where no treatment was done, and then used as control (C) for comparison. Soil samplings were done immediately after treatment and 4 years and two years in M site and J site respectively. We examined the effect of salvage logging on basal soil respiration (BSR), and microbial biomass carbon (Cmic). Our results showed that in site M four years after the treatment, the plots without treatment showed a much better improvement for the properties monitored. And not differences were found in site J after two years of monitoring. The impact of salvage logging was different depending on the soil type and the way to do the treatment.

  17. Abrupt climate-independent fire regime changes

    Science.gov (United States)

    Pausas, Juli G.; Keeley, Jon E.

    2014-01-01

    Wildfires have played a determining role in distribution, composition and structure of many ecosystems worldwide and climatic changes are widely considered to be a major driver of future fire regime changes. However, forecasting future climatic change induced impacts on fire regimes will require a clearer understanding of other drivers of abrupt fire regime changes. Here, we focus on evidence from different environmental and temporal settings of fire regimes changes that are not directly attributed to climatic changes. We review key cases of these abrupt fire regime changes at different spatial and temporal scales, including those directly driven (i) by fauna, (ii) by invasive plant species, and (iii) by socio-economic and policy changes. All these drivers might generate non-linear effects of landscape changes in fuel structure; that is, they generate fuel changes that can cross thresholds of landscape continuity, and thus drastically change fire activity. Although climatic changes might contribute to some of these changes, there are also many instances that are not primarily linked to climatic shifts. Understanding the mechanism driving fire regime changes should contribute to our ability to better assess future fire regimes.

  18. Fire Technology Abstracts, volume 4, issue 1, August, 1981

    Science.gov (United States)

    Holtschlag, L. J.; Kuvshinoff, B. W.; Jernigan, J. B.

    This bibliography contains over 400 citations with abstracts addressing various aspects of fire technology. Subjects cover the dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention, suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, insurance, economics of loss and prevention, and more.

  19. Modeling of compartment fire

    International Nuclear Information System (INIS)

    Sathiah, P.; Siccama, A.; Visser, D.; Komen, E.

    2011-01-01

    Fire accident in a containment is a serious threat to nuclear reactors. Fire can cause substantial loss to life and property. The risk posed by fire can also exceed the risk from internal events within a nuclear reactor. Numerous research efforts have been performed to understand and analyze the phenomenon of fire in nuclear reactor and its consequences. Modeling of fire is an important subject in the field of fire safety engineering. Two approaches which are commonly used in fire modeling are zonal modeling and field modeling. The objective of this work is to compare zonal and field modeling approach against a pool fired experiment performed in a well-confined compartment. Numerical simulations were performed against experiments, which were conducted within PRISME program under the framework of OECD. In these experiments, effects of ventilation flow rate on heat release rate in a confined and mechanically ventilated compartment is investigated. Time dependent changes in gas temperature and oxygen mass fraction were measured. The trends obtained by numerical simulation performed using zonal model and field model compares well with experiments. Further validation is needed before this code can be used for fire safety analyses. (author)

  20. Optical properties of wet paper and simulation of the effect of autoprofiling on gas-fired IR drying

    Energy Technology Data Exchange (ETDEWEB)

    Ojala, K T; Lampinen, M J

    1991-01-01

    We have developed new models to determine the radiative heat transfer of gas-fired infrared dryers. A computer program based on the mathematical models is developed further. This program is used for studying the autoprofiling effect in gas-fired infrared drying. Optical properties of paper samples of different moisture contents as a function of wavelength are systematically measured by using FT-lR specrometer and integraing sphere techniques. These measurements covered the moisture content range of 6- 150 %. A new wavelength range (1.2- 1.9 mm), not properly covered by our earlier measurements, is measured by using a liquid nitrogen cooled detector. The total measured wavelength range is 1.0-20.0 mm. The moisture dependence of the optical properties of coating are calculated by using a theoretical model developed in State Research Centre of Finland, Laboratory of Optoelectronics. The radiation properties of component surfaces of the IR dryer were either measured or taken from literature. The mathematical models are based on the calculation of radiation energy balance between the main surfaces and layers in the dryer section. The energy efficiency can be calculated, when the temperatures of the radiator and the optical properties of all parts of the dryer are known. A computer program based on the models is developed further. The dryer efficiency as a function of the moisture content of paper is calculated. The extent of the autoprofiling effect in gas-fired IR drying is hereby achieved for light weight coated paper web. If the variation in moisture contents is high, the autoprofiling effect takes place and reduces the moisture variation. However, if the moisture variation is low, it is not a very significant phenomenon. The simulation results are compared to a pilot coater trial made in Cenre Technique du Papier, Grenoble.

  1. Co-firing biomass and fossil fuels

    International Nuclear Information System (INIS)

    Junge, D.C.

    1991-01-01

    In June 1989, the Alaska Energy Authority and the University of Alaska Anchorage published a monograph summarizing the technology of co-firing biomass and fossil fuels. The title of the 180 page monograph is 'Use of Mixed Fuels in Direct Combustion Systems'. Highlights from the monograph are presented in this paper with emphasis on the following areas: (1) Equipment design and operational experience co-firing fuels; (2) The impact of co-firing on efficiency; (3) Environmental considerations associated with co-firing; (4) Economic considerations in co-firing; and (5) Decision making criteria for co-firing

  2. Effect of Post-Fire Curing on the Residual Mechanical Properties of Fire-Damaged Self-Compacting Concrete

    NARCIS (Netherlands)

    Mirmomeni, M.; Heidarpour, A.; Schlangen, H.E.J.G.; Smith, S; Saouma, V.; Bolander, J.; Landis, E.

    2016-01-01

    Concrete is recognized for being a fire-resistant construction material. At elevated temperatures concrete can, however, undergo considerable damage such as strength degradation, cracking, and explosive spalling. In recent decades, reuse of fire-damaged concrete structures by means of developing

  3. Fire protection maintenance at Browns Ferry Nuclear Plant

    International Nuclear Information System (INIS)

    Kern, J.R.

    1989-01-01

    This paper describes two approaches to staffing and organizing a fire protection maintenance group. Both have been used at Browns Ferry Nuclear Plant. One takes traditional craft functions and relocates them from the plant maintenance department to the fire protection section. The other expands the role to include response to fire, medical, and hazardous material emergencies. Both approaches remove the fire protection supervisor from a purely staff role, and involve him/her in direct-line management functions. This results in improved technical direction to the craftsmen, improved quality of the work performed, and improved craft morale. It also assures the fire protection supervisor of much more detailed knowledge of the overall status of the fire protection systems

  4. Fire-induced Carbon Emissions and Regrowth Uptake in Western U.S. Forests: Documenting Variation Across Forest Types, Fire Severity, and Climate Regions

    Science.gov (United States)

    Ghimire, Bardan; Williams, Christopher A.; Collatz, George James; Vanderhoof, Melanie

    2012-01-01

    The forest area in the western United States that burns annually is increasing with warmer temperatures, more frequent droughts, and higher fuel densities. Studies that examine fire effects for regional carbon balances have tended to either focus on individual fires as examples or adopt generalizations without considering how forest type, fire severity, and regional climate influence carbon legacies. This study provides a more detailed characterization of fire effects and quantifies the full carbon impacts in relation to direct emissions, slow release of fire-killed biomass, and net carbon uptake from forest regrowth. We find important variations in fire-induced mortality and combustion across carbon pools (leaf, live wood, dead wood, litter, and duff) and across low- to high-severity classes. This corresponds to fire-induced direct emissions from 1984 to 2008 averaging 4 TgC/yr and biomass killed averaging 10.5 TgC/yr, with average burn area of 2723 sq km/yr across the western United States. These direct emission and biomass killed rates were 1.4 and 3.7 times higher, respectively, for high-severity fires than those for low-severity fires. The results show that forest regrowth varies greatly by forest type and with severity and that these factors impose a sustained carbon uptake legacy. The western U.S. fires between 1984 and 2008 imposed a net source of 12.3 TgC/yr in 2008, accounting for both direct fire emissions (9.5 TgC/yr) and heterotrophic decomposition of fire-killed biomass (6.1 TgC yr1) as well as contemporary regrowth sinks (3.3 TgC/yr). A sizeable trend exists toward increasing emissions as a larger area burns annually.

  5. EFFECTS OF IMPREGNATION WITH STYRENE AND NANO-ZINC OXIDE ON FIRE-RETARDING, PHYSICAL, AND MECHANICAL PROPERTIES OF POPLAR WOOD

    Directory of Open Access Journals (Sweden)

    Siroos Habibzade

    2016-12-01

    Full Text Available Nanoparticles have been vastly applied in wood polymer composites (WPCs in the recent years to improve some of the drawbacks of solid wood species. In the present study, the effects of ZnO nanoparticles on fire retarding, physical, and mechanical properties of polymerized poplar wood were investigated. Poplar specimens were impregnated with styrene monomer, containing four different contents of nano-zinc oxide (ZnO (0, 0.5, 1 and 1.5%, based on the dry weight of monomer. Results of the scanning electron microscopy (SEM showed homogeneous dispersion of ZnO nanoparticles in the WPC matrix. Nano-zinc oxide improved physical properties such as dimensional stability and water absorption. Moreover, mechanical properties increased in comparison to the control specimens. The impregnation process also significantly improved some of the fire-retarding properties, including the ignition time; however, the flammability nature of styrene aggravated some others, such as carbonized area. It was concluded that, although most of the properties were improved, the final application of WPC should be taken in to consideration before making decision on whether or not to impregnate populus wood with styrene.

  6. Simulating wall and corner fire tests on wood products with the OSU room fire model

    Science.gov (United States)

    H. C. Tran

    1994-01-01

    This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...

  7. Synthesis of knowledge of extreme fire behavior: volume 2 for fire behavior specialists, researchers, and meteorologists

    Science.gov (United States)

    Paul A. Werth; Brian E. Potter; Martin E. Alexander; Craig B. Clements; Miguel G. Cruz; Mark A. Finney; Jason M. Forthofer; Scott L. Goodrick; Chad Hoffman; W. Matt Jolly; Sara S. McAllister; Roger D. Ottmar; Russell A. Parsons

    2016-01-01

    The National Wildfire Coordinating Group’s definition of extreme fire behavior indicates a level of fire behavior characteristics that ordinarily precludes methods of direct control action. One or more of the following is usually involved: high rate of spread, prolific crowning/ spotting, presence of fire whirls, and strong convection column. Predictability is...

  8. The Effects of Thermophysical Properties and Environmental Conditions on Fire Performance of Intumescent Coatings on Glass Fibre-Reinforced Epoxy Composites.

    Science.gov (United States)

    Kandola, Baljinder K; Luangtriratana, Piyanuch; Duquesne, Sophie; Bourbigot, Serge

    2015-08-11

    Intumescent coatings are commonly used as passive fire protection systems for steel structures. The purpose of this work is to explore whether these can also be used effectively on glass fibre-reinforced epoxy (GRE) composites, considering the flammability of the composites compared to non-flammable steel substrate. The thermal barrier and reaction-to-fire properties of three commercial intumescent coatings on GRE composites have been studied using a cone calorimeter. Their thermophysical properties in terms of heating rate and/or temperature dependent char expansion ratios and thermal conductivities have been measured and correlated. It has been suggested that these two parameters can be used to design coatings to protect composite laminates of defined thicknesses for specified periods of time. The durability of the coatings to water absorption, peeling, impact, and flexural loading were also studied. A strong adhesion between all types of coatings and the substrate was observed. Water soaking had a little effect on the fire performance of epoxy based coatings. All types of 1 mm thick coatings on GRE helped in retaining ~90% of the flexural property after 2 min exposure to 50 kW/m² heat flux whereas the uncoated laminate underwent severe delamination and loss in structural integrity after 1 min.

  9. The Effects of Thermophysical Properties and Environmental Conditions on Fire Performance of Intumescent Coatings on Glass Fibre-Reinforced Epoxy Composites

    Directory of Open Access Journals (Sweden)

    Baljinder K. Kandola

    2015-08-01

    Full Text Available Intumescent coatings are commonly used as passive fire protection systems for steel structures. The purpose of this work is to explore whether these can also be used effectively on glass fibre-reinforced epoxy (GRE composites, considering the flammability of the composites compared to non-flammable steel substrate. The thermal barrier and reaction-to-fire properties of three commercial intumescent coatings on GRE composites have been studied using a cone calorimeter. Their thermophysical properties in terms of heating rate and/or temperature dependent char expansion ratios and thermal conductivities have been measured and correlated. It has been suggested that these two parameters can be used to design coatings to protect composite laminates of defined thicknesses for specified periods of time. The durability of the coatings to water absorption, peeling, impact, and flexural loading were also studied. A strong adhesion between all types of coatings and the substrate was observed. Water soaking had a little effect on the fire performance of epoxy based coatings. All types of 1 mm thick coatings on GRE helped in retaining ~90% of the flexural property after 2 min exposure to 50 kW/m2 heat flux whereas the uncoated laminate underwent severe delamination and loss in structural integrity after 1 min.

  10. 36 CFR 9.46 - Accidents and fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Accidents and fires. 9.46... MINERALS MANAGEMENT Non-Federal Oil and Gas Rights § 9.46 Accidents and fires. The operator shall take technologically feasible precautions to prevent accidents and fires, shall notify the Superintendent within 24...

  11. Fabrication of Robust Super hydrophobic Bamboo Based on ZnO Nano sheet Networks with Improved Water-, UV-, and Fire-Resistant Properties

    International Nuclear Information System (INIS)

    Li, J.; Sun, Q.; Yao, Q.; Wang, J.; Han, Sh.; Jin, Ch.

    2014-01-01

    Bamboo with water-resistant, UV-resistant, and fire-resistant properties was desirable in modern society. In this paper, the original bamboo was firstly treated with ZnO sol and then hydrothermally the ZnO nano sheet networks grow onto the bamboo surface and subsequently modified with fluoro alkyl silane (FAS-17). The FAS-17 treated bamboo substrate exhibited not only robust super hydrophobicity with a high contact angle of 161° but also stable repellency towards simulated acid rain (ph = 3) with a contact angle of 152°. Except for its robust super hydrophobicity, such a bamboo also presents superior water-resistant, UV-resistant, and fire-resistant properties.

  12. Manufacturing of Fire Resistance Geopolymer: A Review

    Directory of Open Access Journals (Sweden)

    Aziz Ikmal Hakem

    2016-01-01

    Full Text Available Protection against fire using inorganic polymer is a new application of engineering technology. Even though, there are varieties of fire-protection materials, there is always a need for the development of new materials with improved thermophysical properties and low cost. Geopolymer composites materials are promising from this point of view. Granulated blast furnace slag, boiler ash and fly ash have been used as the prime materials for forming geopolymers composites. Geopolymers have been studied due to its unique properties such as a good fire resistance. Geopolymer offers an innovative for application associated with the high thermal application. This paper summarizes on the potential of alkaliactivated materials over the past decades along with outlines of the manufacturing of geopolymer composites for fire resistance application.

  13. Effects of salvage logging on soil properties and vegetation recovery in a fire-affected Mediterranean forest: A two year monitoring research.

    Science.gov (United States)

    García-Orenes, F; Arcenegui, V; Chrenková, K; Mataix-Solera, J; Moltó, J; Jara-Navarro, A B; Torres, M P

    2017-05-15

    Post-fire management can have an additional impact on the ecosystem; in some cases, even more severe than the fire. Salvage logging (SL) is a common practice in most fire-affected areas. The management of burnt wood can determine microclimatic conditions and seriously affect soil properties. In some cases, the way of doing it, using heavy machinery, and the vulnerability of soils to erosion and degradation can make this management potentially aggressive to soil. Research was done in "Sierra de Mariola Natural Park" (E Spain). A forest fire (>500ha) occurred in July 2012. In February 2013, SL treatment was applied in a part of the affected forest. Plots for monitoring this effect were installed in this area and in a similar nearby area where no treatment was done, used as control (C). Soil samplings were done immediately after treatment and every 6months during two years. Some soil properties were analysed, including organic matter (OM) content, nitrogen (N) available phosphorous (P) basal soil respiration (BSR), microbial biomass carbon (C mic ), bulk density (BD), water repellency (WR), aggregate stability (AS) and field capacity (FC). SL treatment caused an increase in BD, a decrease of AS, FC, OM and N. In the control area, in general the soil properties remained constant across the 2years of monitoring, and the microbial parameters (BSR and C mic ), initially affected by the fire, recovered faster in C than in the SL area. Plant recovery also showed some differences between treatments. No significant differences were observed in the number of plant species recorded (richness) comparing C versus SL plots, but the number of individuals of each species (evenness) was significantly higher in C plots. In conclusion, we can affirm that for the conditions of this study case, SL had a negative effect on the soil-plant system. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Ash transformation in suspension fired boilers co-firing coal and straw

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Jensen, Peter Arendt; Jensen, Anker Degn

    The properties of the ash from co-firing of coal and straw have a large influence on boiler operation, flue gas cleaning equipment and appropriate utilization of the fly ash. A study on the fuel composition and local conditions influence on fly ash properties has been done by making entrained flo...

  15. Effects of Fire on Soil Properties, Erosion and Hydrologic Regime of Zrebar Lake Watershed

    Directory of Open Access Journals (Sweden)

    Shirko Ebrahimi Mohammadi

    2017-02-01

    Full Text Available Introduction: Forest herbs due to decrease of runoff coefficient and the kinetic energy of raindrops, is known as a key factor in controlling runoff and soil conservation. Many physical (hydrophobicity, electrical conductivity, pH, particle size distribution, color and temperature regimes, chemical (quality and quantity of organic matter, nutrient availability and biological (Microbial biomass, soil invertebrates living community soil properties can be affected by forest fires. Fire not only reduces forest herbs, vulnerability against splashing rain but also has strong effects on the hydrological cycle and soil loss. despite of repeated fires, there are very few studies about fire impact on natural resources of the west of the country, especially the city of Marivan, in Kurdistan province so this study aimed to investigate the short-term fire impacts on soil properties, Hydrologic regime, soil erosion and sedimentation of Zrebar Lake watershed in west of Iran. Materials and Methods: Considering the importance of the slope on the hydrological response of the watershed, slope classes of the Zrebar Lake watershed were mapped. Therefore, effects of fire on hydrological characteristics, erosion and sedimentation were studied by the establishment of twelve 0.25 square meter plots in three replications at two dominant slope classes (0 to 30 and 30 to 60% in burned and natural areas . The first plots in the burned and natural sections, was established randomly and two other plots with the similar conditions at a distance of 1.5 meters from each other were established. Garden Spray Simulator with constant pressure was used to fall rain from half a meter height for thirty minutes with an intensity of about 2 mm min-1 and 1 mm droplet diameter according to the general weather conditions of the studied area. For every five minutes, runoff and sediment were collected. Runoff volume by weighting and suspended sediment concentration by drying at 105°c were

  16. Methods and means of sodium fire fighting

    International Nuclear Information System (INIS)

    Zemskij, G.T.

    1985-01-01

    Methods and means for coaling sodium fire fighting are analyzed. Their advantages and drawbacks are considered. Comparative data on sodium fire fighting using some of considered compositions are presented. High efficiency of self-expanding compositions (Grafeks SK-23 and RS) is noted. Properties of MGS new composition for sodium fire fighting are considered. High fighting ability of the composition independent of burning metal layer width is shown. It is noted that fire fighting MGS efficiency decreases with growth of time of free fire burning which affects fire fighting methods. Technical means of powder delivery to burning sodium are reported

  17. 30 CFR 75.1107-6 - Capacity of fire suppression devices; location and direction of nozzles.

    Science.gov (United States)

    2010-07-01

    ... nozzles of each fire suppression device shall, where practicable, be located so as to take advantage of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Capacity of fire suppression devices; location... Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment...

  18. Fire and smoke retardants

    Science.gov (United States)

    Drews, M. J.

    Despite a reduction in Federal regulatory activity, research concerned with flame retardancy and smoke suppression in the private sector appears to be increasing. This trend seem related to the increased utilization of plastics for end uses which traditionally have employed metal or wood products. As a result, new markets have appeared for thermally stable and fire resistance thermoplastic materials, and this in turn has spurred research and development activity. In addition, public awareness of the dangers associated with fire has increased as a result of several highly publicized hotel and restaurant fires within the past two years. The consumers recognition of flammability characteristics as important materials property considerations has increased. The current status of fire and smoke retardant chemistry and research are summarized.

  19. Comparative analysis of direct and indirect property investment ...

    African Journals Online (AJOL)

    Comparative analysis of direct and indirect property investment returns in Abuja. ... in property shares is more risky than commercial property due to the risk ... of the stock market, it was discovered that there is a strong positive relationship ...

  20. Fire effects on soil and hydrology

    NARCIS (Netherlands)

    Stoof, C.R.

    2011-01-01

    Fire can significantly increase a landscape’s vulnerability to flooding and erosion events. By removing vegetation, changing soil properties and inducing soil water repellency, fire can increase the risk and erosivity of overland flow. Mitigation of land degradation and flooding events after

  1. Tainted with prejudices. Part 1. Directly fired hall heating systems; Mit Vorurteilen behaftet. T. 1. Direktbefeuerte Hallenheizsysteme

    Energy Technology Data Exchange (ETDEWEB)

    Schulte, J. [Jochem Schulte Gruppe, Arnsberg (Germany)

    2008-03-15

    Despite the fact that modern directly fired hall heating systems have many advantages, this branch still faces many concerns from the past. In addition many small craftsmen companies wrongly estimate the installation expenses and are sparing with such installation orders. Nowadays the assembly is not more expensive than the assembly of a conventional heating plant and even the technical requirements are comparable. (orig.)

  2. DOE Fire Protection Handbook, Volume I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The Department of Energy (DOE) Fire Protection Program is delineated in a number of source documents including; the Code of Federal Regulations (CFR), DOE Policy Statements and Orders, DOE and national consensus standards (such as those promulgated by the National Fire Protection Association), and supplementary guidance, This Handbook is intended to bring together in one location as much of this material as possible to facilitate understanding and ease of use. The applicability of any of these directives to individual Maintenance and Operating Contractors or to given facilities and operations is governed by existing contracts. Questions regarding applicability should be directed to the DOE Authority Having Jurisdiction for fire safety. The information provided within includes copies of those DOE directives that are directly applicable to the implementation of a comprehensive fire protection program. They are delineated in the Table of Contents. The items marked with an asterisk (*) are included on the disks in WordPerfect 5.1 format, with the filename noted below. The items marked with double asterisks are provided as hard copies as well as on the disk. For those using MAC disks, the files are in Wordperfect 2.1 for MAC.

  3. Fire severity and ecosytem responses following crown fires in California shrublands.

    Science.gov (United States)

    Keeley, Jon E; Brennan, Teresa; Pfaff, Anne H

    2008-09-01

    Chaparral shrublands burn in large high-intensity crown fires. Managers interested in how these wildfires affect ecosystem processes generally rely on surrogate measures of fire intensity known as fire severity metrics. In shrublands burned in the autumn of 2003, a study of 250 sites investigated factors determining fire severity and ecosystem responses. Using structural equation modeling we show that stand age, prefire shrub density, and the shortest interval of the prior fire history had significant direct effects on fire severity, explaining > 50% of the variation in severity. Fire severity per se is of interest to resource managers primarily because it is presumed to be an indicator of important ecosystem processes such as vegetative regeneration, community recovery, and erosion. Fire severity contributed relatively little to explaining patterns of regeneration after fire. Two generalizations can be drawn: fire severity effects are mostly shortlived, i.e., by the second year they are greatly diminished, and fire severity may have opposite effects on different functional types. Species richness exhibited a negative relationship to fire severity in the first year, but fire severity impacts were substantially less in the second postfire year and varied by functional type. Much of this relationship was due to alien plants that are sensitive to high fire severity; at all scales from 1 to 1000 m2, the percentage of alien species in the postfire flora declined with increased fire severity. Other aspects of disturbance history are also important determinants of alien cover and richness as both increased with the number of times the site had burned and decreased with time since last fire. A substantial number of studies have shown that remote-sensing indices are correlated with field measurements of fire severity. Across our sites, absolute differenced normalized burn ratio (dNBR) was strongly correlated with field measures of fire severity and with fire history at a

  4. The efficacy of fuel treatment in mitigating property loss during wildfires: Insights from analysis of the severity of the catastrophic fires in 2009 in Victoria, Australia.

    Science.gov (United States)

    Price, Owen F; Bradstock, Ross A

    2012-12-30

    Treatment of fuel (e.g. prescribed fire, logging) in fire-prone ecosystems is done to reduce risks to people and their property but effects require quantification, particularly under severe weather conditions when the destructive potential of fires on human infrastructure is maximised. We analysed the relative effects of fuel age (i.e. indicative of the effectiveness of prescribed fire) and logging on remotely sensed (SPOT imagery) severity of fires which occurred in eucalypt forests in Victoria, Australia in 2009. These fires burned under the most severe weather conditions recorded in Australia and caused large losses of life and property. Statistical models of the probability of contrasting extremes of severity (crown fire versus fire confined to the understorey) were developed based on effects of fuel age, logging, weather, topography and forest type. Weather was the primary influence on severity, though it was reduced at low fuel ages in Moderate but not Catastrophic, Very High or Low fire-weather conditions. Probability of crown fires was higher in recently logged areas than in areas logged decades before, indicating likely ineffectiveness as a fuel treatment. The results suggest that recently burnt areas (up to 5-10 years) may reduce the intensity of the fire but not sufficiently to increase the chance of effective suppression under severe weather conditions. Since house loss was most likely under these conditions (67%), effects of prescribed burning across landscapes on house loss are likely to be small when weather conditions are severe. Fuel treatments need to be located close to houses in order to effectively mitigate risk of loss. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  6. Recovery Time After a Late-Dry Season Fire: the Effect on Fluxes, Surface Properties and Vegetation Green-Up.

    Science.gov (United States)

    Saha, M. V.; D'Odorico, P.; Scanlon, T. M.

    2014-12-01

    Large regions of Africa burn on an annual basis. These fires damage vegetation, change surface albedo and modify the hydrologic cycle. Quantifying the magnitude and persistence of these changes is key in understanding the complex ways in which fire affects ecosystem functioning at smaller scales and will inform ongoing modeling efforts. We report the results of a field study in a semi-arid savanna in northern Botswana during the transition from dry to wet season (Oct-Dec) in 2012 and 2013. The goals of this study were to: (1) characterize the multifaceted effect that late dry-season fires have on fluxes and radiative surface processes during green-up, and (2) describe the timescales over which these variables recover to non-burnt levels. Our study synthesizes a suite of data, including flux tower measurements, vegetation sampling, time-lapse photography and concurrent remotely sensed variables over plots with variable burn patterns. Albedo decreased immediately after fire, converging on unburned values 10 days post-burn. The magnitude and direction of this response was comparable to the albedo change elicited by strong rainfall events. Soil temperature and soil heat flux were not significantly modified by fire. Carbon fluxes showed no discernible difference from an unburned control site immediately after fire. There was a small burst in ecosystem respiration at immediately following the first post-fire rainfall event, returning to baseline values after 3 days. Persistent CO2 release, which we attribute to soil respiration, occurred for 10 days after successive strong wetting events, confirming the centrality of available moisture in determining ecosystem function. Fire delayed the green-up in some plots, but this effect was variable and short-lived. One month after fire there was no evidence of a difference in ground observations of greenness between burnt and control plots or plots that differed in their time of burning. We attribute the relatively ephemeral

  7. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part II-Comparison with Experimental Results.

    Science.gov (United States)

    Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge

    2017-04-28

    Based on a phenomenological methodology, a three dimensional (3D) thermochemical model was developed to predict the temperature profile, the mass loss and the decomposition front of a carbon-reinforced epoxy composite laminate (T700/M21 composite) exposed to fire conditions. This 3D model takes into account the energy accumulation by the solid material, the anisotropic heat conduction, the thermal decomposition of the material, the gas mass flow into the composite, and the internal pressure. Thermophysical properties defined as temperature dependant properties were characterised using existing as well as innovative methodologies in order to use them as inputs into our physical model. The 3D thermochemical model accurately predicts the measured mass loss and observed decomposition front when the carbon fibre/epoxy composite is directly impacted by a propane flame. In short, the model shows its capability to predict the fire behaviour of a carbon fibre reinforced composite for fire safety engineering.

  8. Assessment of the material properties of a fire damaged building

    Directory of Open Access Journals (Sweden)

    Oladipupo OLOMO

    2012-12-01

    Full Text Available This study identifies a process for assessing the material properties of a fire damaged building so as to determine whether the remains can be utilized in construction or be demolished. Physical and chemical analysis were carried out on concrete and steel samples taken from various elements of the building after thorough visual inspection of the entire building had been conducted. The physical (non-destructive tests included the Schmidt hammer and ultrasonic pulse velocity tests on the concrete samples, tensile strength test on the steel samples and chemical tests involving the assessment of the quantities of cement, sulphates and chloride concentrations in the samples. A redesign of the building elements was also carried out and the results were compared with the existing design. The non-destructive test results indicated compressive strengths as low as 9.9 N/mm2, the tensile strength test indicated a maximum strength of 397.48 N/mm2 and the chemical test indicated chloride contents as high as 0.534 g per gramme of concrete. These properties deviated significantly from standard requirements. Based on these results, it was concluded that the remains of the building should be demolished.

  9. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Science.gov (United States)

    2010-07-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a thorough knowledge and understanding of the principles of physics and chemistry governing fire growth...

  10. Effect of boron compounds on physical, mechanical, and fire properties of injection molded wood plastic composites

    Science.gov (United States)

    Nadir Ayrilmis; Turgay Akbulut; Turker Dundar; Robert H. White; Fatih Mengeloglu; Zeki Candan; Umit Buyuksari; Erkan Avci

    2011-01-01

    Physical, mechanical, and fire properties of the injection-molded wood flour/polypropylene composites (WPCs) incorporated with different levels of boron compounds, borax/boric acid (BX/BA) (0.5:0.5 wt %) and zinc borate (ZB) (4, 8, or 12 wt %) were investigated. The effect of the coupling agent loading (2, 4, or 6 wt %), maleic anhydride-grafted PP (MAPP), on the...

  11. Assessment of Post Forest Fire Landslides in Uttarakhand Himalaya, India

    Science.gov (United States)

    Sharma, N.; Singh, R. B.

    2017-12-01

    According to Forest Survey of India-State Forest Report (2015), the total geographical area of Uttarakhand is 53, 483 covers km2 out of which 24,402 km2 area covers under total forest covers. As noticed during last week of April, 2016 forest of Uttarakhand mountains was gutted down due to major incidences of fire. This incident caused huge damage to different species of flora-fauna, human being, livestock, property and destruction of mountain ecosystem. As per media reports, six people were lost their lives and recorded several charred carcasses of livestock's due to this incident. The forest fire was affected the eleven out of total thirteen districts which roughly covers the 0.2% (approx.) of total vegetation covers.The direct impact of losses are easy to be estimated but indirect impacts of this forest fire are yet to be occurred. The threat of post Forest fire induced landslides during rainfall is themain concern. Since, after forest fire top soil and rocks are loose due to loss of vegetation as binding and protecting agent against rainfall. Therefore, the pore water pressure and weathering will be very high during rainy season which can cause many landslides in regions affected by forest fire. The demarcation of areas worse affected by forest fire is necessary for issuing alerts to habitations and important infrastructures. These alerts will be based upon region specific probable rainfall forecasting through Indian Meteorological Department (IMD). The main objective is to develop a tool for detecting early forest fire and to create awareness amongst mountain community, researchers and concerned government agencies to take an appropriate measures to minimize the incidences of Forest fire and impact of post forest fire landslides in future through implementation of sustainable mountain strategy.

  12. Climate Impacts of Fire-Induced Land-Surface Changes

    Science.gov (United States)

    Liu, Y.; Hao, X.; Qu, J. J.

    2017-12-01

    One of the consequences of wildfires is the changes in land-surface properties such as removal of vegetation. This will change local and regional climate through modifying the land-air heat and water fluxes. This study investigates mechanism by developing and a parameterization of fire-induced land-surface property changes and applying it to modeling of the climate impacts of large wildfires in the United States. Satellite remote sensing was used to quantitatively evaluate the land-surface changes from large fires provided from the Monitoring Trends in Burning Severity (MTBS) dataset. It was found that the changes in land-surface properties induced by fires are very complex, depending on vegetation type and coverage, climate type, season and time after fires. The changes in LAI are remarkable only if the actual values meet a threshold. Large albedo changes occur in winter for fires in cool climate regions. The signs are opposite between the first post-fire year and the following years. Summer day-time temperature increases after fires, while nigh-time temperature changes in various patterns. The changes are larger in forested lands than shrub / grassland lands. In the parameterization scheme, the detected post-fire changes are decomposed into trends using natural exponential functions and fluctuations of periodic variations with the amplitudes also determined by natural exponential functions. The final algorithm is a combination of the trends, periods, and amplitude functions. This scheme is used with Earth system models to simulate the local and regional climate effects of wildfires.

  13. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    Science.gov (United States)

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  14. 46 CFR 28.315 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... After September 15, 1991, and That Operate With More Than 16 Individuals on Board § 28.315 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel 36 feet (11.8 meters) or more in length must...

  15. Optical properties of wet paper and simulation of the effect of autoprofiling on gas-fired IR drying

    Energy Technology Data Exchange (ETDEWEB)

    Ojala, K T; Lampinen, M J [Helsinki University of Technology (FI)

    1991-12-01

    Mathematical models are developed to determine the radiative heat transfer of gas-fired infrared dryers. These models are based on the calculation of radiation energy balance between the main surfaces and layers in the dryer section. The energy efficiency can be calculated, when the temperatures of the radiator and the optical properties of all parts of the dryer are known. A computer program is used for studying the autoprofiling effect in gas-fired infrared drying. Optical properties of paper samples of different moisture contents as a function of wavelength are systematically measured by using FT-IR spectrometer and integrating sphere techniques. These measurements covered the moisture content range of 6-150%. The total measured wavelength range is 1.0-20.0 {mu}m. The moisture content of paper increases the absorptivity mainly in two wavelength ranges, i.e. 1.4-2.6 {mu}m and 3.75-6.0 {mu}m. In these ranges, the difference between the absorptivity of two sheets (dry weight 41.1 g/m{sup 2}, moisture contents 6.0% and 20.8%) is 5-10%. Outside these ranges, the difference is less than 5%. The radiation properties of component surfaces of the IR dryer were measured or taken from literature. The dryer efficiency as a function of the moisture content of paper is calculated. The extent of the autoprofilling effect in gas-fired IR drying is hereby achieved for light weight coated paper web. In one simulation, before the dryer, the moisture difference between two sheets was 5.0% (=20% - 15%). After the dryer, the moisture difference was reduced to 4.5%. If the variation in moisture contents is high, the autoprofilling effect takes place and reduces the moisture variaton. (AB).

  16. Exploratory Studies Facility Subsurface Fire Hazards Analysis

    International Nuclear Information System (INIS)

    Logan, Richard C.

    2002-01-01

    The primary objective of this Fire Hazard Analysis (FHA) is to confirm the requirements for a comprehensive fire and related hazards protection program for the Exploratory Studies Facility (ESF) are sufficient to minimize the potential for: The occurrence of a fire or related event; A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public or the environment; Vital U.S. Department of Energy (DOE) programs suffering unacceptable interruptions as a result of fire and related hazards; Property losses from a fire and related events exceeding limits established by DOE; and Critical process controls and safety class systems being damaged as a result of a fire and related events

  17. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part I-Characterisation of Thermophysical Properties.

    Science.gov (United States)

    Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge

    2017-05-04

    Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering.

  18. Fire vegetative ash and erosion in the Mediterranean areas. State of the art and future perspectives

    Science.gov (United States)

    Pereira, Paulo; Cerdà, Artemi

    2013-04-01

    Fire is a global phenomenon with important ecological impacts. Among all ecosystems, the Mediterranean is frequently visited by severe wildfires with serious impacts on soil properties and increase soil vulnerability to erosion due vegetation removal. After the fire the ash distributed in soil surface can mitigate soil exposition to erosion and rain splash (Cerda and Doerr, 2008), however, this depends on the fire severity that have implications on the type of ash produced (Pereira et al., 2010). High fire severities produced thinner ash that it is easily transported by wind, contrary to low severity wildfires where combustion is not so intense and the mass loss is less, providing a better soil protection in the immediate period after the fire. Soil protection after the fire highly depends on fire severity (Pereira et al. 2013a; Pereira et al. 2013b). Ash it is a highly mobile material, thus this protection can change in space and time, providing a better cover in some areas and worst in others. In the period immediate after the fire, ash can change soil hydrological properties, increasing water retention and reducing sediment transport in relation to bare soil areas (Cerda and Doerr, 2008), but also clog soil pores, seal the soil and increase erosion (Onda et al., 2008). In fact results are controversial and the impacts of vegetative ash in soil erosion may rely on the proprieties of ash produced, that can be extremely variable, even in small distances (Pereira and Úbeda, 2010), due the different conditions of combustions. Ash produced at low severity temperatures can be highly hydrophilic (Bodi et al., 2011) and induce soil hydrophobicity (Bodi et al., 2012). Other mechanisms as the direct impact of fire in soil, can induce soil water repellency, and do not have any interference of vegetative ash. This fire can induce direct (e.g temperature) and indirect (e.g. ash properties) on soil wettability, with obvious implications on spatio-temporal pattern of soil

  19. Large scale fire experiments in the HDR containment as a basis for fire code development

    International Nuclear Information System (INIS)

    Hosser, D.; Dobbernack, R.

    1993-01-01

    Between 1984 and 1991 7 different series of large scale fire experiments and related numerical and theoretical investigations have been performed in the containment of a high pressure reactor in Germany (known as HDR plant). The experimental part included: gas burner tests for checking the containment behaviour; naturally ventilated fires with wood cribs; naturally and forced ventilated oil pool fires; naturally and forced ventilated cable fires. Many results of the oil pool and cable fires can directly be applied to predict the impact of real fires at different locations in a containment on mechanical or structural components as well as on plant personnel. But the main advantage of the measurements and observations was to serve as a basis for fire code development and validation. Different types of fire codes have been used to predict in advance or evaluate afterwards the test results: zone models for single room and multiple room configurations; system codes for multiple room configurations; field models for complex single room configurations. Finally, there exist codes of varying degree of specialization which have proven their power and sufficient exactness to predict fire effects as a basis for optimum fire protection design. (author)

  20. Analysis of directional radiative behavior and heating efficiency for a gas-fired radiant burner

    International Nuclear Information System (INIS)

    Li, B.X.; Lu, Y.P.; Liu, L.H.; Kudo, K.; Tan, H.P.

    2005-01-01

    For the purpose of energy conservation and uniform heating of object surface, a gas-fired porous radiant burner with a bundle of reflecting tubes is developed. A physical model is developed to simulate the directional radiative behavior of this heating device, in which the Monte Carlo method based on the concept of radiation distribution factor is used to compute the directional radiative behavior. The effects of relating parameters on the directional behavior of radiative heating and the heating efficiency are analyzed. With the increase of the length-to-radius ratio of tube, the radiation heating efficiency decreases, but the radiation energy incident on the object surface is more collimated. The radiation heating efficiency increases with the specular reflectivity. With the increase in length of tube segment with specular reflective surface, the radiation heating efficiency increases, but the extent of concentration and collimation of radiative energy decreases. For real design of the heating device, some trade-offs are needed to balance the radiation heating efficiency and the uniformity of radiative heating of object surface

  1. Rapid response tools and datasets for post-fire modeling: Linking Earth Observations and process-based hydrological models to support post-fire remediation

    Science.gov (United States)

    M. E. Miller; M. Billmire; W. J. Elliot; K. A. Endsley; P. R. Robichaud

    2015-01-01

    Preparation is key to utilizing Earth Observations and process-based models to support post-wildfire mitigation. Post-fire flooding and erosion can pose a serious threat to life, property and municipal water supplies. Increased runoff and sediment delivery due to the loss of surface cover and fire-induced changes in soil properties are of great concern. Remediation...

  2. Effects of fire ash on soil water retention

    NARCIS (Netherlands)

    Stoof, C.R.; Wesseling, J.G.; Ritsema, C.J.

    2010-01-01

    Despite the pronounced effect of fire on soil hydrological systems, information on the direct effect of fire on soil water retention characteristics is limited and contradictory. To increase understanding in this area, the effect of fire on soil water retention was evaluated using laboratory burning

  3. Effects of body formulation and firing temperature to properties of ceramic tile incorporated with electric arc furnace (EAF) slag waste

    Science.gov (United States)

    Sharif, Nurulakmal Mohd; Lim, Chi Yang; Teo, Pao Ter; Seman, Anasyida Abu

    2017-07-01

    Significant quantities of sludge and slag are generated as waste materials or by-products from steel industries. One of the by-products is Electric Arc Furnace (EAF) steel slag which consists of oxides such as CaO, Al2O3 and FeO. This makes it possible for slag to partially replace the raw materials in ceramic tile production. In our preliminary assessment of incorporating the EAF slag into ceramic tile, it was revealed that at fixed firing temperature of 1150°C, the tile of composition 40 wt.% EAF slag - 60 wt.% ball clay has comparable properties with commercial ceramic tile. Thus, this current study would focus on effects of body formulation (different weight percentages of K-feldspar and silica) and different firing temperatures to properties of EAF slag added ceramic tile. EAF slag from Southern Steel Berhad (SSB) was crushed into micron size (EAF slag content was 40 wt.%) and milled with ball clay, K-feldspar and silica before compacted and fired at 1125°C and 1150°C. The EAF slag added tile was characterized in terms of water absorption, apparent porosity, bulk density, modulus of rupture (MOR) and phase analysis via X-ray diffraction (XRD). The composition of 40 wt.% EAF slag - 30 wt.% ball clay - 10 wt.% K-feldspar - 20 wt.% silica (10F_20S), fired at 1150°C showed the lowest water absorption, apparent porosity and highest bulk density due to enhancement of densification process during firing. However, the same composition of ceramic tile (10F_20S) had the highest MOR at lower firing temperature of 1125°C, contributed by presence of the highest total amount of anorthite and wollastonite reinforcement crystalline phases (78.40 wt.%) in the tile. Overall, both the water absorption and MOR of all ceramic tiles surpassed the requirement regulated by MS ISO 13006:2014 Standard (Annex G: Dry-pressed ceramic tile with low water absorption, Eb ≤ 0.50 % and minimum MOR of 35 MPa).

  4. On the fluid mechanics of fires

    Energy Technology Data Exchange (ETDEWEB)

    TIESZEN,SHELDON R.

    2000-02-29

    Fluid mechanics research related to fire is reviewed with focus on canonical flows, multiphysics coupling aspects, experimental and numerical techniques. Fire is a low-speed, chemically-reacting, flow in which buoyancy plans an important role. Fire research has focused on two canonical flows, the reacting boundary-layer and the reacting free plume. There is rich, multi-lateral, bi-directional, coupling among fluid mechanics and scalar transport, combustion, and radiation. There is only a limited experimental fluid-mechanics database for fire due to measurement difficulties in the harsh environment, and the focus within the fire community on thermal/chemical consequences. Increasingly, computational fluid dynamics techniques are being used to provide engineering guidance on thermal/chemical consequences and to study fire phenomenology.

  5. Perceptions of Wildfire Threat and Mitigation Measures by Residents of Fire-Prone Communities in the Northeast: Survey Results and Wildland Fire Management Implications

    Science.gov (United States)

    Robert L. Ryan; Mark B. Wamsley

    2006-01-01

    We surveyed residents of fire-prone areas of the Central Pine Barrens of Long Island, New York, and the Plymouth Pine Barrens in Massachusetts to learn how they perceived wildland fire risk and management techniques for reducing fire hazard. We found that residents considered the fire threat to their own property to be relatively low in spite of first-hand experience...

  6. Exploratory Studies Facility Subsurface Fire Hazards Analysis

    International Nuclear Information System (INIS)

    Kubicek, J. L.

    2001-01-01

    The primary objective of this Fire Hazard Analysis (FHA) is to confirm the requirements for a comprehensive fire and related hazards protection program for the Exploratory Studies Facility (ESF) are sufficient to minimize the potential for: (1) The occurrence of a fire or related event. (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public or the environment. (3) Vital US. Department of Energy (DOE) programs suffering unacceptable interruptions as a result of fire and related hazards. (4) Property losses from a fire and related events exceeding limits established by DOE. (5) Critical process controls and safety class systems being damaged as a result of a fire and related events

  7. A Study of Coal Fire Propagation with Remotely Sensed Thermal Infrared Data

    Directory of Open Access Journals (Sweden)

    Hongyuan Huo

    2015-03-01

    Full Text Available Coal fires are a common and serious problem in most coal-bearing countries. Thus, it is very important to monitor changes in coal fires. Remote sensing provides a useful technique for investigating coal fields at a large scale and for detecting coal fires. In this study, the spreading direction of a coal fire in the Wuda Coal Field (WCF, northwest China, was analyzed using multi-temporal Landsat Thematic Mapper (TM and Enhanced Thematic Mapper (ETM+ thermal infrared (TIR data. Using an automated method and based on the land surface temperatures (LST that were retrieved from these thermal data, coal fires related to thermal anomalies were identified; the locations of these fires were validated using a coal fire map (CFM that was developed via field surveys; and the cross-validation of the results was also carried out using the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER thermal infrared images. Based on the results from longtime series of satellite TIR data set, the spreading directions of the coal fires were determined and the coal fire development on the scale of the entire coal field was predicted. The study delineated the spreading direction using the results of the coal fire dynamics analysis, and a coal fire spreading direction map was generated. The results showed that the coal fires primarily spread north or northeast in the central part of the WCF and south or southwest in the southern part of the WCF. In the northern part of the WCF, some coal fires were spreading north, perhaps coinciding with the orientation of the coal belt. Certain coal fires scattered in the northern and southern parts of the WCF were extending in bilateral directions. A quantitative analysis of the coal fires was also performed; the results indicate that the area of the coal fires increased an average of approximately 0.101 km2 per year.

  8. Remote sensing fire and fuels in southern California

    Science.gov (United States)

    Philip Riggan; Lynn Wolden; Bob Tissell; David Weise; J. Coen

    2011-01-01

    Airborne remote sensing at infrared wavelengths has the potential to quantify large-fire properties related to energy release or intensity, residence time, fuel-consumption rate, rate of spread, and soil heating. Remote sensing at a high temporal rate can track fire-line outbreaks and acceleration and spotting ahead of a fire front. Yet infrared imagers and imaging...

  9. Fire retardant polyisocyanurate foam

    Science.gov (United States)

    Riccitiello, S. R.; Parker, J. A.

    1972-01-01

    Fire retardant properties of low density polymer foam are increased. Foam has pendant nitrile groups which form thermally-stable heterocyclic structures at temperature below degradation temperature of urethane linkages.

  10. Repository Subsurface Preliminary Fire Hazard Analysis

    International Nuclear Information System (INIS)

    Logan, Richard C.

    2001-01-01

    This fire hazard analysis identifies preliminary design and operations features, fire, and explosion hazards, and provides a reasonable basis to establish the design requirements of fire protection systems during development and emplacement phases of the subsurface repository. This document follows the Technical Work Plan (TWP) (CRWMS M and O 2001c) which was prepared in accordance with AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities''; Attachment 4 of AP-ESH-008, ''Hazards Analysis System''; and AP-3.11Q, ''Technical Reports''. The objective of this report is to establish the requirements that provide for facility nuclear safety and a proper level of personnel safety and property protection from the effects of fire and the adverse effects of fire-extinguishing agents

  11. Extinguisher powder for liquid metal fires

    Energy Technology Data Exchange (ETDEWEB)

    Menzenhauer, P; Ochs, G [Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorentwicklung

    1978-11-01

    The extinguisher introduced here based on graphite exhibited considerably improved extinguishing properties compared to other extinguishing powders. It has no aggressive properties, is, as for as could be tested in the short time available, non-hygroscopic and thus very easy to remove after extinguishing and cooling of the fire. The amount of extinguisher necessary is only a fraction of the amounts needed of other common powders. Storage is no problem and nerely a small storage amount is required. This extinguisher is excellently suitable for fighting sodium surface fires.

  12. Extinguisher powder for liquid metal fires

    International Nuclear Information System (INIS)

    Menzenhauer, P.; Ochs, G.

    1978-01-01

    The extinguisher introduced here based on graphite exhibited considerably improved extinguishing properties compared to other extinguishing powders. It has no aggressive properties, is, as for as could be tested in the short time available, non-hygroscopic and thus very easy to remove after extinguishing and cooling of the fire. The amount of extinguisher necessary is only a fraction of the amounts needed of other common powders. Storage is no problem and nerely a small storage amount is required. This extinguisher is excellently suitable for fighting sodium surface fires. (orig./HP) [de

  13. Evaluation of technical feasibility of closed-cycle non-equilibrium MHD power generation with direct coal firing. Final report, Task 1

    Energy Technology Data Exchange (ETDEWEB)

    1981-11-01

    Program accomplishments in a continuing effort to demonstrate the feasibility of direct coal fired, closed cycle, magnetohydrodynamic power generation are detailed. These accomplishments relate to all system aspects of a CCMHD power generation system including coal combustion, heat transfer to the MHD working fluid, MHD power generation, heat and cesium seed recovery and overall systems analysis. Direct coal firing of the combined cycle has been under laboratory development in the form of a high slag rejection, regeneratively air cooled cyclone coal combustor concept, originated within this program. A hot bottom ceramic regenerative heat exchanger system was assembled and test fired with coal for the purposes of evaluating the catalytic effect of alumina on NO/sub x/ emission reduction and operability of the refractory dome support system. Design, procurement, fabrication and partial installation of a heat and seed recovery flow apparatus was accomplished and was based on a stream tube model of the full scale system using full scale temperatures, tube sizes, rates of temperature change and tube geometry. Systems analysis capability was substantially upgraded by the incorporation of a revised systems code, with emphasis on ease of operator interaction as well as separability of component subroutines. The updated code was used in the development of a new plant configuration, the Feedwater Cooled (FCB) Brayton Cycle, which is superior to the CCMHD/Steam cycle both in performance and cost. (WHK)

  14. Short Jute Fiber Reinforced Polypropylene Composites: Effect of Nonhalogenated Fire Retardants

    Directory of Open Access Journals (Sweden)

    Sk. Sharfuddin Chestee

    2017-01-01

    Full Text Available Short jute fiber reinforced polypropylene (PP composites were prepared using a single screw extrusion moulding. Jute fiber content in the composites is optimized with the extent of mechanical properties, and composites with 20% jute show higher mechanical properties. Dissimilar concentrations of several fire retardants (FRs, such as magnesium oxide (MO, aluminum oxide (AO, and phosphoric acid (PA, were used in the composites. The addition of MO, AO, and PA improved the fire retardancy properties (ignition time, flame height, and total firing time of the composites. Ignition time for 30% MO, flame height for 30% PA, and total firing time for 20% MO content composites showed good results which were 8 sec, 1 inch, and 268 sec, respectively. Mechanical properties (tensile strength, tensile modulus, bending strength, bending modulus, and elongation at break, degradation properties (soil test, weathering test, and percentage of weight loss, and water uptake were studied.

  15. 77 FR 58492 - Prohibitions Governing Fire

    Science.gov (United States)

    2012-09-21

    ... DEPARTMENT OF AGRICULTURE Forest Service 36 CFR Part 261 RIN 0596-AD08 Prohibitions Governing Fire AGENCY: Forest Service, USDA. ACTION: Direct final rule. SUMMARY: The Forest Service is making purely... Fire. * * * * * (j) Operating or using any internal or external combustion engine without a spark...

  16. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Green,T.

    2009-10-23

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the

  17. Assessing Wildfire Risk in Cultural Heritage Properties Using High Spatial and Temporal Resolution Satellite Imagery and Spatially Explicit Fire Simulations: The Case of Holy Mount Athos, Greece

    Directory of Open Access Journals (Sweden)

    Giorgos Mallinis

    2016-02-01

    Full Text Available Fire management implications and the design of conservation strategies on fire prone landscapes within the UNESCO World Heritage Properties require the application of wildfire risk assessment at landscape level. The objective of this study was to analyze the spatial variation of wildfire risk on Holy Mount Athos in Greece. Mt. Athos includes 20 monasteries and other structures that are threatened by increasing frequency of wildfires. Site-specific fuel models were created by measuring in the field several fuel parameters in representative natural fuel complexes, while the spatial extent of the fuel types was determined using a synergy of high-resolution imagery and high temporal information from medium spatial resolution imagery classified through object-based analysis and a machine learning classifier. The Minimum Travel Time (MTT algorithm, as it is embedded in FlamMap software, was applied in order to evaluate Burn Probability (BP, Conditional Flame Length (CFL, Fire Size (FS, and Source-Sink Ratio (SSR. The results revealed low burn probabilities for the monasteries; however, nine out of the 20 monasteries have high fire potential in terms of fire intensity, which means that if an ignition occurs, an intense fire is expected. The outputs of this study may be used for decision-making for short-term predictions of wildfire risk at an operational level, contributing to fire suppression and management of UNESCO World Heritage Properties.

  18. The vestibulo- and preposito-cerebellar cholinergic neurons of a ChAT-tdTomato transgenic rat exhibit heterogeneous firing properties and the expression of various neurotransmitter receptors.

    Science.gov (United States)

    Zhang, Yue; Kaneko, Ryosuke; Yanagawa, Yuchio; Saito, Yasuhiko

    2014-04-01

    Cerebellar function is regulated by cholinergic mossy fiber inputs that are primarily derived from the medial vestibular nucleus (MVN) and prepositus hypoglossi nucleus (PHN). In contrast to the growing evidence surrounding cholinergic transmission and its functional significance in the cerebellum, the intrinsic and synaptic properties of cholinergic projection neurons (ChPNs) have not been clarified. In this study, we generated choline acetyltransferase (ChAT)-tdTomato transgenic rats, which specifically express the fluorescent protein tdTomato in cholinergic neurons, and used them to investigate the response properties of ChPNs identified via retrograde labeling using whole-cell recordings in brainstem slices. In response to current pulses, ChPNs exhibited two afterhyperpolarisation (AHP) profiles and three firing patterns; the predominant AHP and firing properties differed between the MVN and PHN. Morphologically, the ChPNs were separated into two types based on their soma size and dendritic extensions. Analyses of the firing responses to time-varying sinusoidal current stimuli revealed that ChPNs exhibited different firing modes depending on the input frequencies. The maximum frequencies in which each firing mode was observed were different between the neurons that exhibited distinct firing patterns. Analyses of the current responses to the application of neurotransmitter receptor agonists revealed that the ChPNs expressed (i) AMPA- and NMDA-type glutamate receptors, (ii) GABAA and glycine receptors, and (iii) muscarinic and nicotinic acetylcholine receptors. The current responses mediated by these receptors of MVN ChPNs were not different from those of PHN ChPNs. These findings suggest that ChPNs receive various synaptic inputs and encode those inputs appropriately across different frequencies. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  19. Synchronization of two coupled turbulent fires

    Science.gov (United States)

    Takagi, Kazushi; Gotoda, Hiroshi; Miyano, Takaya; Murayama, Shogo; Tokuda, Isao T.

    2018-04-01

    We numerically study the scale-free nature of a buoyancy-induced turbulent fire and synchronization of two coupled turbulent fires. A scale-free structure is detected in weighted networks between vortices, while its lifetime obeys a clear power law, indicating intermittent appearances, disappearances, and reappearances of the scale-free property. A significant decrease in the distance between the two fire sources gives rise to a synchronized state in the near field dominated by the unstable motion of large-scale of transverse vortex rings. The synchronized state vanishes in the far field forming well-developed turbulent plumes, regardless of the distance between the two fire sources.

  20. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part I—Characterisation of Thermophysical Properties

    Directory of Open Access Journals (Sweden)

    Pauline Tranchard

    2017-05-01

    Full Text Available Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA, Simultaneous Thermal analysis (STA, Laser Flash analysis (LFA, and Fourier Transform Infrared (FTIR analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper. The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering.

  1. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part I—Characterisation of Thermophysical Properties

    Science.gov (United States)

    Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge

    2017-01-01

    Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering. PMID:28772854

  2. Model of large pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Fay, J.A. [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)]. E-mail: jfay@mit.edu

    2006-08-21

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables.

  3. Model of large pool fires

    International Nuclear Information System (INIS)

    Fay, J.A.

    2006-01-01

    A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables

  4. Risk Insights Gained from Fire Incidents

    International Nuclear Information System (INIS)

    Kazarians, Mardy; Nowlen, Steven P.

    1999-01-01

    There now exist close to 20 years of history in the application of Probabilistic Risk Assessment (PRA) for the analysis of fire risk at nuclear power plants. The current methods are based on various assumptions regarding fire phenomena, the impact of fire on equipment and operator response, and the overall progression of a fire event from initiation through final resolution. Over this same time period, a number of significant fire incidents have occurred at nuclear power plants around the world. Insights gained from US experience have been used in US studies as the statistical basis for establishing fire initiation frequencies both as a function of the plant area and the initiating fire source.To a lesser extent, the fire experience has also been used to assess the general severity and duration of fires. However, aside from these statistical analyses, the incidents have rarely been scrutinized in detail to verify the underlying assumptions of fire PRAs. This paper discusses an effort, under which a set of fire incidents are being reviewed in order to gain insights directly relevant to the methods, data, and assumptions that form the basis for current fire PRAs. The paper focuses on the objectives of the effort, the specific fire events being reviews methodology, and anticipated follow-on activities

  5. A Mega-fire event in Central Russia: fire weather, radiative, and optical properties of the atmosphere, and consequences for subboreal forest plants

    Science.gov (United States)

    Nataly Y. Chubarova; Nickolay G. Prilepsky; Alexei N. Rublev; Allen R. Riebau

    2009-01-01

    In 2002, a major drought and prolonged high temperatures occurred in central Russia that resulted in unprecedented wildland fires. These fires occurred under extreme fire danger conditions and were impossible for the Russian authorities to extinguish. It is perhaps somewhat unique that the fires were first burning peat bogs and later forests, causing very massive smoke...

  6. Modelling of Fire in an Open Car Park

    DEFF Research Database (Denmark)

    Marton, Timea; Dederichs, Anne Simone; Giuliani, Luisa

    2015-01-01

    Steel car parks exhibit high vulnerability to fire, as a consequence of the degradation of the steel mechanical properties at high temperatures and of the combustible type and amount. Real fire accidents in open car parks demonstrated a much faster and extended fire spread than predictions......, assuming that a fire spread rate of 12 min and consider at most 3-4 vehicles on fire at the same time. Fire Dynamic Simulator (FDS) is applied in this current paper to study fire spread between cars. The outcomes of the investigations show that the fire spread is strongly influenced by the geometrical...... layout and that the distance between cars plays a determinant role on the fire spread rate and ignition of adjacent cars. In particular it was found that the fire spread can be faster than 12 minutes in the case of the cars parked 40 and 60 cm from each other....

  7. ESTIMATION OF NEAR SUBSURFACE COAL FIRE GAS EMISSIONS BASED ON GEOPHYSICAL INVESTIGATIONS

    Science.gov (United States)

    Chen-Brauchler, D.; Meyer, U.; Schlömer, S.; Kus, J.; Gundelach, V.; Wuttke, M.; Fischer, C.; Rueter, H.

    2009-12-01

    Spontaneous and industrially caused subsurface coal fires are worldwide disasters that destroy coal resources, cause air pollution and emit a large amount of green house gases. Especially in developing countries, such as China, India and Malaysia, this problem has intensified over the last 15 years. In China alone, 10 to 20 million tons of coal are believed to be lost in uncontrolled coal fires. The cooperation of developing countries and industrialized countries is needed to enforce internationally concerted approaches and political attention towards the problem. The Clean Development Mechanism (CDM) under the framework of the Kyoto Protocol may provide an international stage for financial investment needed to fight the disastrous situation. A Sino-German research project for coal fire exploration, monitoring and extinction applied several geophysical approaches in order to estimate the annual baseline especially of CO2 emissions from near subsurface coal fires. As a result of this project, we present verifiable methodologies that may be used in the CDM framework to estimate the amount of CO2 emissions from near subsurface coal fires. We developed three possibilities to approach the estimation based on (1) thermal energy release, (2) geological and geometrical determinations as well as (3) direct gas measurement. The studies involve the investigation of the physical property changes of the coal seam and bedrock during different burning stages of a underground coal fire. Various geophysical monitoring methods were applied from near surface to determine the coal volume, fire propagation, temperature anomalies, etc.

  8. The theory, direction, and magnitude of ecosystem fire probability as constrained by precipitation and temperature.

    Science.gov (United States)

    Guyette, Richard; Stambaugh, Michael C; Dey, Daniel; Muzika, Rose Marie

    2017-01-01

    The effects of climate on wildland fire confronts society across a range of different ecosystems. Water and temperature affect the combustion dynamics, irrespective of whether those are associated with carbon fueled motors or ecosystems, but through different chemical, physical, and biological processes. We use an ecosystem combustion equation developed with the physical chemistry of atmospheric variables to estimate and simulate fire probability and mean fire interval (MFI). The calibration of ecosystem fire probability with basic combustion chemistry and physics offers a quantitative method to address wildland fire in addition to the well-studied forcing factors such as topography, ignition, and vegetation. We develop a graphic analysis tool for estimating climate forced fire probability with temperature and precipitation based on an empirical assessment of combustion theory and fire prediction in ecosystems. Climate-affected fire probability for any period, past or future, is estimated with given temperature and precipitation. A graphic analyses of wildland fire dynamics driven by climate supports a dialectic in hydrologic processes that affect ecosystem combustion: 1) the water needed by plants to produce carbon bonds (fuel) and 2) the inhibition of successful reactant collisions by water molecules (humidity and fuel moisture). These two postulates enable a classification scheme for ecosystems into three or more climate categories using their position relative to change points defined by precipitation in combustion dynamics equations. Three classifications of combustion dynamics in ecosystems fire probability include: 1) precipitation insensitive, 2) precipitation unstable, and 3) precipitation sensitive. All three classifications interact in different ways with variable levels of temperature.

  9. The theory, direction, and magnitude of ecosystem fire probability as constrained by precipitation and temperature.

    Directory of Open Access Journals (Sweden)

    Richard Guyette

    Full Text Available The effects of climate on wildland fire confronts society across a range of different ecosystems. Water and temperature affect the combustion dynamics, irrespective of whether those are associated with carbon fueled motors or ecosystems, but through different chemical, physical, and biological processes. We use an ecosystem combustion equation developed with the physical chemistry of atmospheric variables to estimate and simulate fire probability and mean fire interval (MFI. The calibration of ecosystem fire probability with basic combustion chemistry and physics offers a quantitative method to address wildland fire in addition to the well-studied forcing factors such as topography, ignition, and vegetation. We develop a graphic analysis tool for estimating climate forced fire probability with temperature and precipitation based on an empirical assessment of combustion theory and fire prediction in ecosystems. Climate-affected fire probability for any period, past or future, is estimated with given temperature and precipitation. A graphic analyses of wildland fire dynamics driven by climate supports a dialectic in hydrologic processes that affect ecosystem combustion: 1 the water needed by plants to produce carbon bonds (fuel and 2 the inhibition of successful reactant collisions by water molecules (humidity and fuel moisture. These two postulates enable a classification scheme for ecosystems into three or more climate categories using their position relative to change points defined by precipitation in combustion dynamics equations. Three classifications of combustion dynamics in ecosystems fire probability include: 1 precipitation insensitive, 2 precipitation unstable, and 3 precipitation sensitive. All three classifications interact in different ways with variable levels of temperature.

  10. The impact of wildland fires on calcareous Mediterranean pedosystems (Sardinia, Italy) - An integrated multiple approach.

    Science.gov (United States)

    Capra, Gian Franco; Tidu, Simona; Lovreglio, Raffaella; Certini, Giacomo; Salis, Michele; Bacciu, Valentina; Ganga, Antonio; Filzmoser, Peter

    2018-05-15

    Sardinia (Italy), the second largest island of the Mediterranean Sea, is a fire-prone land. Most Sardinian environments over time were shaped by fire, but some of them are too intrinsically fragile to withstand the currently increasing fire frequency. Calcareous pedoenvironments represent a significant part of Mediterranean areas, and require important efforts to prevent long-lasting degradation from fire. The aim of this study was to assess through an integrated multiple approach the impact of a single and highly severe wildland fire on limestone-derived soils. For this purpose, we selected two recently burned sites, Sant'Antioco and Laconi. Soil was sampled from 80 points on a 100×100m grid - 40 in the burned area and 40 in unburned one - and analyzed for particle size fractions, pH, electrical conductivity, organic carbon, total N, total P, and water repellency (WR). Fire behavior (surface rate of spread (ROS), fireline intensity (FLI), flame length (FL)) was simulated by BehavePlus 5.0.5 software. Comparisons between burned and unburned areas were done through ANOVA as well as deterministic and stochastic interpolation techniques; multiple correlations among parameters were evaluated by principal factor analysis (PFA) and differences/similarities between areas by principal component analysis (PCA). In both sites, fires were characterized by high severity and determined significant changes to some soil properties. The PFA confirmed the key ecological role played by fire in both sites, with the variability of a four-modeled components mainly explained by fire parameters, although the induced changes on soils were mainly site-specific. The PCA revealed the presence of two main "driving factors": slope (in Sant'Antioco), which increased the magnitude of ROS and FLI; and soil properties (in Laconi), which mostly affected FL. In both sites, such factors played a direct role in differentiating fire behavior and sites, while they played an indirect role in determining

  11. The Ndop plain clayey materials (Bamenda area – NW Cameroon: Mineralogical, geochemical, physical characteristics and properties of their fired products

    Directory of Open Access Journals (Sweden)

    Rose Yongue-Fouateu

    2016-09-01

    Full Text Available The physicochemical, mineralogical and technological properties of clayey materials from the Ndop plain (NW Cameroon have been investigated, for their ceramic applications. The clayey materials have mixed facies with colour ranging from brown, grey, mottled and yellowish brown. The thickness of the exploitable clay layer is more than 5 m. Their mineralogical constituents are quartz, kaolinite, illite and feldspars, with kaolinite as major clay mineral. Based on the geochemistry, their source rocks might be felsic, with a mafic rock inference. These materials display high percentage in fine particles and high Atterberg limits. For all the firing temperatures, flexural strength (1.2–11 MPa, water absorption (8.03–24.27%, linear shrinkage (2.10%, weight loss (4.88–16.54% and bulk density (1.57–2.03 g/cm3 indicate good ceramic properties for firing samples between 900 and 1100 °C. Most of the fired test bricks show a brick red colour with good to very good cohesion. The studied clays were thus, suitable as raw materials for roof tiles, light weight blocks and hollow bricks; however, mixing of high clayey and highly silty materials could improve the quality of the products.

  12. Human Factors in Fire Safety Management and Prevention

    Directory of Open Access Journals (Sweden)

    M.A. Othuman Mydin

    2014-07-01

    Full Text Available Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. It involves the study of the behavior, compartmentalization, and investigation of fire and its related emergencies, as well as the research and development, production, testing and application of mitigating systems. Problems still occurred despite of the adequate fire safety systems installed. For most people in high-risk buildings, not all accidents were caused by them. They were more likely to be the victims of a fire that occurred. Besides damaging their properties and belongings, some people were burned to death for not knowing what to do if fire happens in their place. This paper will present the human factors in fire safety management and prevention system.

  13. Fire, humans and landscape. Is there a connection?

    Science.gov (United States)

    Valese, Eva; Ascoli, Davide; Conedera, Marco; Held, Alex

    2013-04-01

    Fire evolved on the earth under the direct influence of climate and the accumulation of burnable biomass at various times and spatial scales. As a result, fire regimes depend not only on climatic and biological factors, but also greatly reflect the cultural background of how people do manage ecosystems and fire. A new awareness among scientists and managers has been rising about the ecological role of fire and the necessity to understand its past natural and cultural dynamics in different ecosystems, in order to preserve present ecosystem functionality and minimize management costs and negative impacts. As a consequence we assisted in the last decades to a general shift from the fire control to the fire management approach, where fire prevention, fire danger rating, fire ecology, fire pre-suppression and suppression strategies are fully integrated in the landscape management. Nowadays, a large number of authors recognize that a total suppression strategy, as the one adopted during last decades, leads to a fire paradox: the more we fight for putting out all fires, the more extreme events occur and cause long term damages. The aim of this review is to provide a state of art about the connection between fire, humans and landscape, along time and space. Negative and positive impacts on ecosystem services and values are put in evidence, as well as their incidence on human aptitude to fire use as to fire suppression. In order to capture a consistent fragment of fire history, palaeofires and related palynological studies are considered. They enable a valuable, even if partial, look at the millenary fire regime. Actual strategies and future directions are described in order to show what are the alternatives for living with fire, since removing completely this disturbance from earth is not a option, nor feasible neither advisable. Examples from the world, in particular from the Alps and the Mediterranean basin, are shown for better illustrating the signature of

  14. Process simulation of co-firing torrefied biomass in a 220 MWe coal-fired power plant

    International Nuclear Information System (INIS)

    Li, Jun; Zhang, Xiaolei; Pawlak-Kruczek, Halina; Yang, Weihong; Kruczek, Pawel; Blasiak, Wlodzimierz

    2014-01-01

    Highlights: • The performances of torrefaction based co-firing power plant are simulated by using Aspen Plus. • Mass loss properties and released gaseous components have been studied during biomass torrefaction processes. • Mole fractions of CO 2 and CO account for 69–91% and 4–27% in total torrefied gases. • The electrical efficiency reduced when increasing either torrefaction temperature or substitution ratio of biomass. - Abstract: Torrefaction based co-firing in a pulverized coal boiler has been proposed for large percentage of biomass co-firing. A 220 MWe pulverized coal-power plant is simulated using Aspen Plus for full understanding the impacts of an additional torrefaction unit on the efficiency of the whole power plant, the studied process includes biomass drying, biomass torrefaction, mill systems, biomass/coal devolatilization and combustion, heat exchanges and power generation. Palm kernel shells (PKS) were torrefied at same residence time but 4 different temperatures, to prepare 4 torrefied biomasses with different degrees of torrefaction. During biomass torrefaction processes, the mass loss properties and released gaseous components have been studied. In addition, process simulations at varying torrefaction degrees and biomass co-firing ratios have been carried out to understand the properties of CO 2 emission and electricity efficiency in the studied torrefaction based co-firing power plant. According to the experimental results, the mole fractions of CO 2 and CO account for 69–91% and 4–27% in torrefied gases. The predicted results also showed that the electrical efficiency reduced when increasing either torrefaction temperature or substitution ratio of biomass. A deep torrefaction may not be recommended, because the power saved from biomass grinding is less than the heat consumed by the extra torrefaction process, depending on the heat sources

  15. Fire, carbon, and climate change

    International Nuclear Information System (INIS)

    Amiro, B.; Flannigan, M.

    2005-01-01

    One million hectares of forest are harvested in Canada annually, with 1 to 8 million hectares destroyed by fire and a further 10 to 25 million hectares consumed by insects. Enhanced disturbances have meant that Canadian forests are becoming carbon sources instead of carbon sinks. Canadian fire statistics from the year 1920 were provided along with a map of large fires between 1980 and 1999. A cycle of combustion losses, decomposition and regeneration of forests was presented, along with a stylized concept of forest carbon life cycles with fire. Direct emissions from forests fires were evaluated. An annual net ecosystem production in Canadian boreal forests and stand age was presented. Projections of areas burned were presented based on weather and fire danger relationships, with statistics suggesting that a 75 to 120 per cent increase is likely to occur by the end of this century. Trend observations show that areas burned are correlated with increasing temperature caused by anthropogenic effects. Prevention, detection, suppression and fuels management were presented as areas that needed improvement in fire management. However, management strategies may only postpone an increase in forest fires. Changes in disturbances such as fire and insects will be a significant early impact of climate change on forests. tabs., figs

  16. Calibration of the CAFE-3D fire code with controlled indoor fire data

    International Nuclear Information System (INIS)

    Lopez, C.; Koski, J.A.; Khalil, I.; Suo-Anttila, A.

    2004-01-01

    The Container Analysis Fire Environment (CAFE) code contains a computational fluid dynamics (CFD) based fire model that has been successfully coupled to standard finite element computer codes. This coupling of CFD and finite element codes allows for a more realistic modeling of the thermal performance of objects engulfed in fire, which aids in the design and risk analysis of radioactive material packages. The CAFE fire model is based on a three-dimensional finite volume formulation of basic fire chemistry and fluid dynamics. This fire model includes a variable-density primitive-variable formulation of mass, momentum, energy and species equations. Multiple chemical species and soot formation are included in the combustion model. Thermal radiation is modeled as diffusive radiation transport inside the flame zone and as view-factor radiation outside the flame zone. Turbulence is modeled with an eddy diffusivity model. The soot model is coupled to the diffusive radiation formulation using the Rosseland approximation and the optical properties of soot. In order to verify and improve the accuracy of computers codes, they should be benchmarked against test data. This paper describes a set of experiments that were performed at the Fire Laboratory for Accreditation of Modeling by Experiment (FLAME) fire facility of Sandia National Laboratories in Albuquerque, New Mexico, USA. The paper also describes how the data collected from the experiments was used to calibrate and benchmark the CAFE-3D fire code. Detailed description of the tests performed and comparisons between the calculated results and the collected data from the experiments are provided

  17. Fire-retardant decorative inks for aircraft interiors

    Science.gov (United States)

    Kourtides, D. A.; Nir, Z.; Mikroyannidis, J. A.

    1985-01-01

    Commercial and experimental fire retardants were screened as potential fire retardants for acrylic printing inks used on aircraft interior sandwich panels. The fire retardants are selected according to their physical properties and their thermostabilities. A criterion for selecting a more stable fire retardant is established. Thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) are used to determine thermostabilities. Results show that the fire retardant formulations are more thermally stable than the acrylic ink control. It is determined that an ink formulation containing a brominated phenol and carboxy-terminated butadiene acrylonitrile which has been modified with a brominated polymeric additive (BPA), yields the highest limiting oxygen index (LOI) of all the compounds tested. All of the fire-retardant formulations have a higher oxygen index than the baseline acrylic ink.

  18. Fire management of California shrubland landscapes

    Science.gov (United States)

    Keeley, Jon E.

    2002-01-01

    Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.

  19. PG BN 1600 sodium fire protection system

    International Nuclear Information System (INIS)

    Bar, J.; Urbancik, L.

    1978-12-01

    A design was developed of a fire protection system for steam generator of a 1600 MW sodium cooled fast reactor (BN-1600). Chemical reactions are described of liquid sodium with atmospheric components and solid materials coming into contact with sodium in its release from the steam generator, and in safeguarding protection against sodium fires. The requirements for the purity of nitrogen as an atmosphere inert to liquid sodium are given. Characteristics and basic parameters are shown of level and spray fires, elementary terms are explained concerning the properties of aerosols formed during fires, the methods and means of release signalling and fire alarm are described as are fire precautions using fire-fighting equipment, modifying the support tank and the cell bottom and building sewage pits. The design of the system comprises an alarm system for liquid sodium using point and line electric contact sensors and flame photometer based aerosol sensors as well as a fire-fighting system based on the system of channelling liquid sodium into emergency discharge tanks filled with an inert gas, a set of fire extinguishers and other fire fighting material, and measures for the elimination of sodium fire consequences. (J.B.)

  20. Material Analysis for a Fire Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Alexander; Nemer, Martin B.

    2014-08-01

    This report consolidates technical information on several materials and material classes for a fire assessment. The materials include three polymeric materials, wood, and hydraulic oil. The polymers are polystyrene, polyurethane, and melamine- formaldehyde foams. Samples of two of the specific materials were tested for their behavior in a fire - like environment. Test data and the methods used to test the materials are presented. Much of the remaining data are taken from a literature survey. This report serves as a reference source of properties necessary to predict the behavior of these materials in a fire.

  1. Colemanite: a fire retardant candidate for wood plastic composites

    Science.gov (United States)

    Evren Terzi; Saip Nami Kartal; Sabriye Piskin; Nicole Stark; Aysel Kanturk Figen; Robert H. White

    2018-01-01

    The use of raw boron minerals (i.e. tincalconite, colemanite, and ulexite) was evaluated to increase the fire performance of wood plastic composites (WPCs) in comparison with commercially available fire retardants (FRs). Cone calorimetry and limited oxygen index tests were performed to evaluate the fire properties of WPC specimens. Artificial weathering and 3-point...

  2. Surface Fire Hazards Analysis Technical Report-Constructor Facilities

    International Nuclear Information System (INIS)

    Flye, R.E.

    2000-01-01

    The purpose of this Fire Hazards Analysis Technical Report (hereinafter referred to as Technical Report) is to assess the risk from fire within individual fire areas to ascertain whether the U.S. Department of Energy (DOE) fire safety objectives are met. The objectives identified in DOE Order 420.1, Change 2, Facility Safety, Section 4.2, establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: The occurrence of a fire or related event; A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public, or the environment; Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards; Property losses from a fire and related events exceeding defined limits established by DOE; and Critical process controls and safety class systems being damaged as a result of a fire and related events

  3. Control Properties of Bottom Fired Marine Boilers

    DEFF Research Database (Denmark)

    Solberg, Brian; Andersen, Palle; Karstensen, Claus M. S.

    2007-01-01

    This paper focuses on model analysis of a dynamic model of a bottom fired one-pass smoke tube boiler. Linearized versions of the model are analyzed and show large variations in system gains at steady state as function of load whereas gain variations near the desired bandwidth are small. An analys...

  4. [Corrosion property and oxide film of dental casting alloys before and after porcelain firing].

    Science.gov (United States)

    Ma, Qian; Wu, Feng-ming

    2011-03-01

    To evaluate the types and compositions of oxide films formed during porcelain-fused-to-metal (PFM) firing on three kinds of dental casting alloys, and to investigate the corrosion property of these alloys in Dulbecco's modification of Eagle's medium (DMEM) cell culture fluid, before and after PFM firing. Specimens of three dental casting alloys (Ni-Cr, Co-Cr and Ni-Ti) before and after PFM firing were prepared, and were immersed in DMEM cell culture fluid. After 30 days, the type and concentration of released metal ions were measured using inductively coupled plasma atomic emission spectroscopy (ICP-AES). X-ray photoelectron spectroscopy (XPS) and scanning electron microscope (SEM) were used for analysis of oxide film on the alloys. One way-ANOVA was adopted in data analysis. The total amount of metal ions released from the three dental alloys was found to be highest in Ni-Cr alloy [(2.829 ± 0.694) mg/L], followed by Co-Cr [(2.120 ± 0.418) mg/L] and Ni-Ti alloy [(1.211 ± 0.101) mg/L]. The amount of Ni ions released from Ni-Cr alloys [(1.531 ± 0.392) mg/L] was higher than that from Ni-Ti alloys [(0.830 ± 0.052) mg/L]. The amount of Cr, Mo ions released from Co-Cr alloy [Cr: (0.048 ± 0.011) mg/L, Mo: (1.562 ± 0.333) mg/L] was higher than that from Ni-Cr alloy [Cr: (0.034 ± 0.002) mg/L, Mo: (1.264 ± 0.302) mg/L] and Ni-Ti alloy [Cr: (0.013 ± 0.006) mg/L, Mo: (0.151 ± 0.026) mg/L] (P < 0.05). After PFM firing, the total amount of metal irons released from the three dental alloys decreased [Ni-Cr: (0.861 ± 0.054) mg/L, Co-Cr: (0.695 ± 0.327) mg/L, Ni-Ti: (0.892 ± 0.115) mg/L] (P < 0.05). In addition, XPS showed increase of Cr(2)O(3) and Mo-Ni oxide on the surface of all the alloys after PFM firing. The amount of ions released from Ni-Cr alloy was the highest among the three dental casting alloys, this means Ni-Cr alloy is prone to corrode. The PFM firing process changed the alloys' surface composition. Increased Ni, Cr and Mo were found in oxide film, and

  5. Infrared optical properties of a coal-fired power plant plume

    International Nuclear Information System (INIS)

    Stearns, L.P.; Pueschel, R.F.

    1983-01-01

    Infrared measurements in the 8--14-μm spectral region were made of two coal-fired power plant plumes and area haze in the Four Corners region of New Mexico from 1 to 7 Nov. 1980. The layer tranmittance, optical depth, and volume extinction coefficient derived from measurements on four nonconsecutive days show the effects of the plumes on the IR optical properties of the atmosphere. The average contribution of the plume alone to the IR extinction coefficient was 74% at the Four Corners plant; the background haze contributed 7--11%. More efficient particulate emission control at the San Juan power plant reduced the average contribution of its plume to 57% of the extinction coefficient. The haze contributed an average of 16%. The results show an increase with time of the haze bulk extinction coefficient during a persistent anticyclonic synoptic situation. Extinction coefficients of the haze showed a linearity with particulate loading, which led to estimates of IR volume extinctions of the free troposphre from aerosol measurements

  6. Modeling post-fire hydro-geomorphic recovery in the Waldo Canyon Fire

    Science.gov (United States)

    Kinoshita, Alicia; Nourbakhshbeidokhti, Samira; Chin, Anne

    2016-04-01

    Wildfire can have significant impacts on watershed hydrology and geomorphology by changing soil properties and removing vegetation, often increasing runoff and soil erosion and deposition, debris flows, and flooding. Watershed systems may take several years or longer to recover. During this time, post-fire channel changes have the potential to alter hydraulics that influence characteristics such as time of concentration and increase time to peak flow, flow capacity, and velocity. Using the case of the 2012 Waldo Canyon Fire in Colorado (USA), this research will leverage field-based surveys and terrestrial Light Detection and Ranging (LiDAR) data to parameterize KINEROS2 (KINematic runoff and EROSion), an event oriented, physically-based watershed runoff and erosion model. We will use the Automated Geospatial Watershed Assessment (AGWA) tool, which is a GIS-based hydrologic modeling tool that uses commonly available GIS data layers to parameterize, execute, and spatially visualize runoff and sediment yield for watersheds impacted by the Waldo Canyon Fire. Specifically, two models are developed, an unburned (Bear Creek) and burned (Williams) watershed. The models will simulate burn severity and treatment conditions. Field data will be used to validate the burned watersheds for pre- and post-fire changes in infiltration, runoff, peak flow, sediment yield, and sediment discharge. Spatial modeling will provide insight into post-fire patterns for varying treatment, burn severity, and climate scenarios. Results will also provide post-fire managers with improved hydro-geomorphic modeling and prediction tools for water resources management and mitigation efforts.

  7. Hotel and Motel Fire Safety Project - USFA

    Data.gov (United States)

    Department of Homeland Security — Provides a listing of properties compliant with the requirements of the Hotel and Motel Fire Safety Act of 1990. Users may search for compliant properties and submit...

  8. Fire as a galvanizing and fragmenting influence on communities: the case of the Rodeo-Chediski fire

    Science.gov (United States)

    Matthew S. Carroll; Patricia J. Cohn; David N. Seesholtz; Lorie L. Higgins

    2005-01-01

    Large wildfires that burn through the "forest-residential intermix" are complex events with a variety of social impacts. This study looks at three northern Arizona community clusters directly affected by the 2002 Rodeo-Chediski fire. Our analysis suggests that the fire event led to both the emergence of cohesion and conflict in the study area. Community...

  9. Application Study of Fire Severity Classification

    International Nuclear Information System (INIS)

    Kim, In Hwan; Kim, Hyeong Taek; Jee, Moon Hak; Kim, Yun Jung

    2013-01-01

    This paper introduces the Fire Incidents Severity Classification Method for Korean NPPs that may be derived directly from the data fields and feasibility study for domestic uses. FEDB was characterized in more detail and assessed based on the significance of fire incidents in the updated database and five fire severity categories were defined. The logical approach to determine the fire severity starts from the most severe characteristics, namely challenging fires, and continues to define the less challenging and undetermined categories in progress. If the FEDB is utilized for Korean NPPs, the ways of Fire Severity Classification suggested in 2.4 above can be utilized for the quantitative fire risk analysis in future. The Fire Events Database (FEDB) is the primary source of fire data which are used for fire frequency in Fire PSA (Probabilistic Safety Assessment). The purpose of its development is to calculate the quantitative fire frequency at the comprehensive and consolidated source derived from the fire incident information available for Nuclear Power Plants (NPPs). Recently, the Fire Events Database (FEDB) was updated by Electric Power Research Institute (EPRI) and Nuclear Regulatory Commission (NRC) in U. S. The FEDB is intended to update the fire event history up to 2009. A significant enhancement to it is the reorganization and refinement of the database structure and data fields. It has been expanded and improved data fields, coding consistency, incident detail, data review fields, and reference data source traceability. It has been designed to better support several Fire PRA uses as well

  10. Stronger Fire-Resistant Epoxies

    Science.gov (United States)

    Fohlen, George M.; Parker, John A.; Kumar, Devendra

    1988-01-01

    New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.

  11. Effects of Burn Severity and Environmental Conditions on Post-Fire Regeneration in Siberian Larch Forest

    Directory of Open Access Journals (Sweden)

    Thuan Chu

    2017-03-01

    Full Text Available Post-fire forest regeneration is strongly influenced by abiotic and biotic heterogeneity in the pre- and post-fire environments, including fire regimes, species characteristics, landforms, hydrology, regional climate, and soil properties. Assessing these drivers is key to understanding the long-term effects of fire disturbances on forest succession. We evaluated multiple factors influencing patterns of variability in a post-fire boreal Larch (Larix sibirica forest in Siberia. A time-series of remote sensing images was analyzed to estimate post-fire recovery as a response variable across the burned area in 1996. Our results suggested that burn severity and water content were primary controllers of both Larch forest recruitment and green vegetation cover as defined by the forest recovery index (FRI and the fractional vegetation cover (FVC, respectively. We found a high rate of Larch forest recruitment in sites of moderate burn severity, while a more severe burn was the preferable condition for quick occupation by vegetation that included early seral communities of shrubs, grasses, conifers and broadleaf trees. Sites close to water and that received higher solar energy during the summer months showed a higher rate of both recovery types, defined by the FRI and FVC, dependent on burn severity. In addition to these factors, topographic variables and pre-fire condition were important predictors of post-fire forest patterns. These results have direct implications for the post-fire forest management in the Siberian boreal Larch region.

  12. Fire Regime Characteristics along Environmental Gradients in Spain

    Directory of Open Access Journals (Sweden)

    María Vanesa Moreno

    2016-11-01

    Full Text Available Concern regarding global change has increased the need to understand the relationship between fire regime characteristics and the environment. Pyrogeographical theory suggests that fire regimes are constrained by climate, vegetation and fire ignition processes, but it is not obvious how fire regime characteristics are related to those factors. We used a three-matrix approach with a multivariate statistical methodology that combined an ordination method and fourth-corner analysis for hypothesis testing to investigate the relationship between fire regime characteristics and environmental gradients across Spain. Our results suggest that fire regime characteristics (i.e., density and seasonality of fire activity are constrained primarily by direct gradients based on climate, population, and resource gradients based on forest potential productivity. Our results can be used to establish a predictive model for how fire regimes emerge in order to support fire management, particularly as global environmental changes impact fire regime characteristics.

  13. Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose

    Directory of Open Access Journals (Sweden)

    Marta Ferreiro-González

    2016-05-01

    Full Text Available Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose has been developed for the analysis of Ignitable Liquid Residues (ILRs. The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA and linear discriminant analysis (LDA were applied to the MS data (45–200 m/z to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin were used to ignite different substrates (wood, cotton, cork, paper and paperboard. A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses.

  14. Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose

    Science.gov (United States)

    Ferreiro-González, Marta; Barbero, Gerardo F.; Palma, Miguel; Ayuso, Jesús; Álvarez, José A.; Barroso, Carmelo G.

    2016-01-01

    Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose) has been developed for the analysis of Ignitable Liquid Residues (ILRs). The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA) and linear discriminant analysis (LDA) were applied to the MS data (45–200 m/z) to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin) were used to ignite different substrates (wood, cotton, cork, paper and paperboard). A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses. PMID:27187407

  15. Disentangling the drivers of coarse woody debris behavior and carbon gas emissions during fire

    Science.gov (United States)

    Zhao, Weiwei; van der Werf, Guido R.; van Logtestijn, Richard S. P.; van Hal, Jurgen R.; Cornelissen, Johannes H. C.

    2016-04-01

    The turnover of coarse woody debris, a key terrestrial carbon pool, plays fundamental roles in global carbon cycling. Biological decomposition and fire are two main fates for dead wood turnover. Compared to slow decomposition, fire rapidly transfers organic carbon from the earth surface to the atmosphere. Both a-biotic environmental factors and biotic wood properties determine coarse wood combustion and thereby its carbon gas emissions during fire. Moisture is a key inhibitory environmental factor for fire. The properties of dead wood strongly affect how it burns either directly or indirectly through interacting with moisture. Coarse wood properties vary between plant species and between various decay stages. Moreover, if we put a piece of dead wood in the context of a forest fuel bed, the soil and wood contact might also greatly affect their fire behavior. Using controlled laboratory burns, we disentangled the effects of all these driving factors: tree species (one gymnosperms needle-leaf species, three angiosperms broad-leaf species), wood decay stages (freshly dead, middle decayed, very strongly decayed), moisture content (air-dried, 30% moisture content in mass), and soil-wood contact (on versus 3cm above the ground surface) on dead wood flammability and carbon gas efflux (CO2 and CO released in grams) during fire. Wood density was measured for all coarse wood samples used in our experiment. We found that compared to other drivers, wood decay stages have predominant positive effects on coarse wood combustion (for wood mass burned, R2=0.72 when air-dried and R2=0.52 at 30% moisture content) and associated carbon gas emissions (for CO2andCO (g) released, R2=0.55 when air-dried and R2=0.42 at 30% moisture content) during fire. Thus, wood decay accelerates wood combustion and its CO2 and CO emissions during fire, which can be mainly attributed to the decreasing wood density (for wood mass burned, R2=0.91 when air-dried and R2=0.63 at 30% moisture content) as wood

  16. Properties and Performance of Rubberwood Particleboard Treated With Bp® Fire Retardant

    OpenAIRE

    Izran K.; Abood F.; Yap K. C.; Abdul Rashid A. M.; Zaidon A.

    2011-01-01

    Rubberwood composites are available in many sizes and are frequently used as furniture and partitioning inputs. However they are naturally combustible and may limit its usage for other value-added products. Treating wood composites with fire retardant was one of the most effective ways to prevent such occurrence. In this study, Rubberwood (Hevea brasiliensis) particleboards were incorporated with BP® fire retardant through hot and cold soaking processes. Four different concentrations of fire ...

  17. Modelling the meteorological forest fire niche in heterogeneous pyrologic conditions.

    Science.gov (United States)

    De Angelis, Antonella; Ricotta, Carlo; Conedera, Marco; Pezzatti, Gianni Boris

    2015-01-01

    Fire regimes are strongly related to weather conditions that directly and indirectly influence fire ignition and propagation. Identifying the most important meteorological fire drivers is thus fundamental for daily fire risk forecasting. In this context, several fire weather indices have been developed focussing mainly on fire-related local weather conditions and fuel characteristics. The specificity of the conditions for which fire danger indices are developed makes its direct transfer and applicability problematic in different areas or with other fuel types. In this paper we used the low-to-intermediate fire-prone region of Canton Ticino as a case study to develop a new daily fire danger index by implementing a niche modelling approach (Maxent). In order to identify the most suitable weather conditions for fires, different combinations of input variables were tested (meteorological variables, existing fire danger indices or a combination of both). Our findings demonstrate that such combinations of input variables increase the predictive power of the resulting index and surprisingly even using meteorological variables only allows similar or better performances than using the complex Canadian Fire Weather Index (FWI). Furthermore, the niche modelling approach based on Maxent resulted in slightly improved model performance and in a reduced number of selected variables with respect to the classical logistic approach. Factors influencing final model robustness were the number of fire events considered and the specificity of the meteorological conditions leading to fire ignition.

  18. Salvage logging effect on soil properties in a fire-affected Mediterranean forest: a two years monitoring research

    Science.gov (United States)

    Mataix-Solera, Jorge; Moltó, Jorge; Arcenegui, Vicky; García-Orenes, Fuensanta; Chrenkovà, Katerina; Torres, Pilar; Jara-Navarro, Ana B.; Díaz, Gisela; Izquierdo, Ezequiel

    2015-04-01

    In the Mediterranean countries, forest fires are common and must be considered as an ecological factor, but changes in land use, especially in the last five decades have provoked a modification in their natural regime. Moreover, post-fire management can have an additional impact on the ecosystem; in some cases, even more severe than the fire. Salvage logging is a traditional management in most fire-affected areas. In some cases, the way of doing it, using heavy machinery, and the vulnerability of soils to erosion and degradation make this management potentially very agresive to soil, and therefore to the ecosystem. Very little research has been done to study how this treatment could affect soil health. In this research we show 2 years of monitoring of some soil properties in an area affected by a forest fire, where some months later this treatment was applied. The study area is located in 'Sierra de Mariola Natural Park' in Alcoi, Alicante (E Spain). A big forest fire (>500 has) occurred in July 2012. The forest is composed mainly of Pinus halepensis trees with an understory of typical Mediterranean shrubs species such as Quercus coccifera, Rosmarinus officinalis, Thymus vulgaris, Brachypodium retusum, etc. Soil is classified as a Typic Xerorthent (Soil Survey Staff, 2014) developed over marls. In February 2013, salvage logging (SL) treatment consisting in a complete extraction of the burned wood using heavy machinery was applied in a part of the affected forest. Plots for monitoring this effect were installed in this area and in a similar nearby area where no treatment was done, and then used as control (C) for comparison. Soil samplings were done immediately after treatment and every 6 months. Some soil properties were analysed, including soil organic matter (SOM) content, basal soil respiration (BSR), microbial biomass carbon (MBC), bulk density (BD), soil water repellency (SWR), aggregate stability (AS), field capacity, nitrogen, etc. After two years of

  19. Monitoring the degradation of physical properties and fire hazards of high-impact polystyrene composite with different ageing time in natural environments.

    Science.gov (United States)

    Wang, Bibo; Zhang, Yan; Tao, Youji; Zhou, Xia; Song, Lei; Jie, Ganxin; Hu, Yuan

    2018-06-15

    The current study aims at monitoring the role of the different natural environments on the physical properties and fire hazards of HIPS composites ageing in Turpan and Qionghai. The results indicated that the chromatic aberration and degradation of surface appearance intensified with the increasing ageing time. More flame retardants migrated and were eroded for HIPS composites ageing in Qionghai than those ageing in Turpan, which was caused by the combination of sunlight, high temperature and rainwater in Qionghai. After degradation in the natural environments, the HIPS composites possessed the lower thermal stability and char residues, more toxic gases release, higher peak heat release rate and fire hazard. For example, the peak heat release rate in Qionghai increased by 88.9%, which is much higher than that of in Turpan (55.6%). Moreover, the tensile strength and elongation at break decreased by 46% and 59% for HIPS composites ageing in Turpan and reduced by 53% and 67% for HIPS composites aged in Qionghai, respectively. The results demonstrate that more serious degradation of physical properties and higher fire hazard for HIPS composites ageing in Qionghai than those in Turpan due to the different natural ageing environments. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Fire-Retardant, Self-Extinguishing Inorganic/Polymer Composite Memory Foams.

    Science.gov (United States)

    Chatterjee, Soumyajyoti; Shanmuganathan, Kadhiravan; Kumaraswamy, Guruswamy

    2017-12-27

    Polymeric foams used in furniture and automotive and aircraft seating applications rely on the incorporation of environmentally hazardous fire-retardant additives to meet fire safety norms. This has occasioned significant interest in novel approaches to the elimination of fire-retardant additives. Foams based on polymer nanocomposites or based on fire-retardant coatings show compromised mechanical performance and require additional processing steps. Here, we demonstrate a one-step preparation of a fire-retardant ice-templated inorganic/polymer hybrid that does not incorporate fire-retardant additives. The hybrid foams exhibit excellent mechanical properties. They are elastic to large compressional strain, despite the high inorganic content. They also exhibit tunable mechanical recovery, including viscoelastic "memory". These hybrid foams are prepared using ice-templating that relies on a green solvent, water, as a porogen. Because these foams are predominantly comprised of inorganic components, they exhibit exceptional fire retardance in torch burn tests and are self-extinguishing. After being subjected to a flame, the foam retains its porous structure and does not drip or collapse. In micro-combustion calorimetry, the hybrid foams show a peak heat release rate that is only 25% that of a commercial fire-retardant polyurethanes. Finally, we demonstrate that we can use ice-templating to prepare hybrid foams with different inorganic colloids, including cheap commercial materials. We also demonstrate that ice-templating is amenable to scale up, without loss of mechanical performance or fire-retardant properties.

  1. Fire-retardant foams

    Science.gov (United States)

    Gagliani, J.

    1978-01-01

    Family of polyimide resins are being developed as foams with exceptional fire-retardant properties. Foams are potentially useful for seat cushions in aircraft and ground vehicles and for applications such as home furnishings and building-construction materials. Basic formulations can be modified with reinforcing fibers or fillers to produce celular materials for variety of applications. By selecting reactants, polymer structure can be modified to give foams with properties ranging from high resiliency and flexibility to brittleness and rigidity.

  2. WILDLAND FIRE MANAGEMENT PLAN FOR BROOKHAVEN NATIONAL LABORATORY.

    Energy Technology Data Exchange (ETDEWEB)

    ENVIRONMENTAL AND WASTE MANAGEMENT SERVICES DIVISION

    2003-09-01

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) and the Upton Ecological and Research Reserve (Upton Reserve) is based on the U.S. Fish & Wildlife Service (FWS) fire management planning procedures and was developed in cooperation with the Department of Energy (DOE) by Brookhaven Science Associates. As the Upton Reserve is contained within the BNL 5,265-acre site, it is logical that the plan applies to both the Upton Reserve and BNL. The Department of the Interior policy for managing wildland fires requires that all areas managed by FWS that can sustain fire must have an FMP that details fire management guidelines for operational procedures and specifies values to be protected or enhanced. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL/Upton Reserve Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered and threatened species and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL and the Upton Reserve. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of FWS, BNL, and the Upton Reserve. This Fire Management Plan is a modified version of the Long Island National Wildlife Refuge Complex Fire plan (updated in 2000), which contains all FWS fire plan requirements and is presented in the format specified by the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. FWS shall be, through an Interagency Agreement dated November 2000 (Appendix C), responsible for coordinating and

  3. Supporting FIRE-suppression strategies combining fire spread MODelling and SATellite data in an operational context in Portugal: the FIRE-MODSAT project

    Science.gov (United States)

    Sá, Ana C. L.; Benali, Akli; Pinto, Renata M. S.; Pereira, José M. C.; Trigo, Ricardo M.; DaCamara, Carlos C.

    2014-05-01

    Large wildfires are infrequent but account for the most severe environmental, ecological and socio-economic impacts. In recent years Portugal has suffered the impact of major heat waves that fuelled records of burnt area exceeding 400.000ha and 300.000ha in 2003 and 2005, respectively. According to the latest IPCC reports, the frequency and amplitude of summer heat waves over Iberia will very likely increase in the future. Therefore, most climate change studies point to an increase in the number and extent of wildfires. Thus, an increase in both wildfire impacts and fire suppression difficulties is expected. The spread of large wildfires results from a complex interaction between topography, meteorology and fuel properties. Wildfire spread models (e.g. FARSITE) are commonly used to simulate fire growth and behaviour and are an essential tool to understand their main drivers. Additionally, satellite active-fire data have been used to monitor the occurrence, extent, and spread of wildfires. Both satellite data and fire spread models provide different types of information about the spatial and temporal distribution of large wildfires and can potentially be used to support strategic decisions regarding fire suppression resource allocation. However, they have not been combined in a manner that fully exploits their potential and minimizes their limitations. A knowledge gap still exists in understanding how to minimize the impacts of large wildfires, leading to the following research question: What can we learn from past large wildfires in order to mitigate future fire impacts? FIRE-MODSAT is a one-year funded project by the Portuguese Foundation for the Science and Technology (FCT) that is founded on this research question, with the main goal of improving our understanding on the interactions between fire spread and its environmental drivers, to support fire management decisions in an operational context and generate valuable information to improve the efficiency of the

  4. Characterization of biomass burning aerosols from forest fire in Indonesia

    Science.gov (United States)

    Fujii, Y.; Iriana, W.; Okumura, M.; Lestari, P.; Tohno, S.; Akira, M.; Okuda, T.

    2012-12-01

    Biomass burning (forest fire, wild fire) is a major source of pollutants, generating an estimate of 104 Tg per year of aerosol particles worldwide. These particles have adverse human health effects and can affect the radiation budget and climate directly and indirectly. Eighty percent of biomass burning aerosols are generated in the tropics and about thirty percent of them originate in the tropical regions of Asia (Andreae, 1991). Several recent studies have reported on the organic compositions of biomass burning aerosols in the tropical regions of South America and Africa, however, there is little data about forest fire aerosols in the tropical regions of Asia. It is important to characterize biomass burning aerosols in the tropical regions of Asia because the aerosol properties vary between fires depending on type and moisture of wood, combustion phase, wind conditions, and several other variables (Reid et al., 2005). We have characterized PM2.5 fractions of biomass burning aerosols emitted from forest fire in Indonesia. During the dry season in 2012, PM2.5 aerosols from several forest fires occurring in Riau, Sumatra, Indonesia were collected on quartz and teflon filters with two mini-volume samplers. Background aerosols in forest were sampled during transition period of rainy season to dry season (baseline period). Samples were analyzed with several analytical instruments. The carbonaceous content (organic and elemental carbon, OC and EC) of the aerosols was analyzed by a thermal optical reflectance technique using IMPROVE protocol. The metal, inorganic ion and organic components of the aerosols were analyzed by X-ray Fluorescence (XRF), ion chromatography and gas chromatography-mass spectrometry, respectively. There was a great difference of chemical composition between forest fire and non-forest fire samples. Smoke aerosols for forest fires events were composed of ~ 45 % OC and ~ 2.5 % EC. On the other hand, background aerosols for baseline periods were

  5. Multiple Property Cross Direction Control of Paper Machines

    Directory of Open Access Journals (Sweden)

    Markku Ohenoja

    2011-07-01

    Full Text Available Cross direction (CD control in sheet-forming process forms a challenging problem with high dimensions. Accounting the interactions between different properties and actuators, the dimensionality increases further and also computational issues arise. We present a multiple property controller feasible to be used especially with imaging measurements that provide high sampling frequency and therefore enable short control interval. The simulation results state the benefits of multiple property CD control over single property control and single property control using full feedforward compensation. The controller presented may also be tuned in automated manner and the results demonstrate the effect of tuning on input saturation.

  6. Soil surface changes increase runoff and erosion risk after a low–moderate severity fire

    NARCIS (Netherlands)

    Stoof, C.R.; Ferreira, A.J.D.; Mol, W.; Berg, van den J.; Kort, De A.; Drooger, S.; Slingerland, E.C.; Mansholt, A.U.; Ritsema, C.J.

    2015-01-01

    Post-fire land degradation is to a large degree determined by what happens to soil properties and ground cover during and after the fire. To study fire impact in relation to fire intensity and post-fire soil exposure, a 9-ha Portuguese shrubland catchmentwas burned by experimental fire in the 2008/9

  7. Rigid Polyurethane Nanocomposites Prepared by Direct Incorporation: Effects of Nanoclay, Carbon Nanotubes and Mixing Speed on Physical and Morphological Properties

    Science.gov (United States)

    Ramadhoni, Benni; Ujianto, Onny; Nadapdap, Maxwell

    2018-03-01

    Rigid polyurethane (PU) nanocomposites were fabricated via solution mixing of PU, nanoclay and multiwalled carbon nanotubes (MWCNT) according to full factorial DoE. The nanoclay and MWCNT concentration as well as mixing speed were varied. The effects of controlled variables on reduced compressive strength, fire retardancy, hardness and morphological properties were analized. In general, the results showed that incorporation of nanofillers into PU matrix successfully elevated nanocomposites performance. The properties changed from -12% to 45% for reduced compressive strength, 9% to 30% for reduced fire retardancy and -32% to 101% for reduced hardness. The results suggested that the improvements were affected by nanoclay dispersion that acted as nucleating agent which resulted in smaller close cells of PU structures.

  8. Wildland fire limits subsequent fire occurrence

    Science.gov (United States)

    Sean A. Parks; Carol Miller; Lisa M. Holsinger; Scott Baggett; Benjamin J. Bird

    2016-01-01

    Several aspects of wildland fire are moderated by site- and landscape-level vegetation changes caused by previous fire, thereby creating a dynamic where one fire exerts a regulatory control on subsequent fire. For example, wildland fire has been shown to regulate the size and severity of subsequent fire. However, wildland fire has the potential to influence...

  9. High Temperature Corrosion in Biomass-Fired Boilers

    DEFF Research Database (Denmark)

    Henriksen, Niels; Montgomery, Melanie; Hede Larsen, Ole

    2002-01-01

    condense on superheater components. This gives rise to specific corrosion problems not previously encountered in coal-fired power plants. The type of corrosion attack can be directly ascribed to the composition of the deposit and the metal surface temperature. To avoid such high corrosion rates, woodchip...... has also been utilised as a fuel. Combustion of woodchip results in a smaller amount of ash, and potassium and chlorine are present in lesser amounts. However, significant corrosion rates were still seen. A case study of a woodchip fired boiler is described. The corrosion mechanisms in both straw-fired...... and woodchip fired boilers are discussed....

  10. Fuel buildup and potential fire behavior after stand-replacing fires, logging fire-killed trees and herbicide shrub removal in Sierra Nevada forests

    Science.gov (United States)

    McGinnis, Thomas W.; Keeley, Jon E.; Stephens, Scott L.; Roller, Gary B.

    2010-01-01

    Typically, after large stand-replacing fires in mid-elevation Sierra Nevada forests, dense shrub fields occupy sites formerly occupied by mature conifers, until eventually conifers overtop and shade out shrubs. Attempting to reduce fuel loads and expedite forest regeneration in these areas, the USDA Forest Service often disrupts this cycle by the logging of fire-killed trees, replanting of conifers and killing of shrubs. We measured the effects of these treatments on live and dead fuel loads and alien species and modeled potential fire behavior and fire effects on regenerating forests. Sampling occurred in untreated, logged and herbicide-treated stands throughout the Sierra Nevada in four large fire areas 4–21 years after stand-replacing fires. Logging fire-killed trees significantly increased total available dead fuel loads in the short term but did not affect shrub cover, grass and forb cover, alien species cover or alien species richness. Despite the greater available dead fuel loads, fire behavior was not modeled to be different between logged and untreated stands, due to abundant shrub fuels in both logged and untreated stands. In contrast, the herbicide treatment directed at shrubs resulted in extremely low shrub cover, significantly greater alien species richness and significantly greater alien grass and forb cover. Grass and forb cover was strongly correlated with solar radiation on the ground, which may be the primary reason that grass and forb cover was higher in herbicide treated stands with low shrub and tree cover. Repeat burning exacerbated the alien grass problem in some stands. Although modeled surface fire flame lengths and rates of spread were found to be greater in stands dominated by shrubs, compared to low shrub cover conifer plantations, surface fire would still be intense enough to kill most trees, given their small size and low crown heights in the first two decades after planting.

  11. Alcohol skin preparation causes surgical fires.

    Science.gov (United States)

    Rocos, B; Donaldson, L J

    2012-03-01

    Surgical fires are a rare but serious preventable safety risk in modern hospitals. Data from the US show that up to 650 surgical fires occur each year, with up to 5% causing death or serious harm. This study used the National Reporting and Learning Service (NRLS) database at the National Patient Safety Agency to explore whether spirit-based surgical skin preparation fluid contributes to the cause of surgical fires. The NRLS database was interrogated for all incidents of surgical fires reported between 1 March 2004 and 1 March 2011. Each report was scrutinised manually to discover the cause of the fire. Thirteen surgical fires were reported during the study period. Of these, 11 were found to be directly related to spirit-based surgical skin preparation or preparation soaked swabs and drapes. Despite manufacturer's instructions and warnings, surgical fires continue to occur. Guidance published in the UK and US states that spirit-based skin preparation solutions should continue to be used but sets out some precautions. It may be that fire risk should be included in pre-surgical World Health Organization checklists or in the surgical training curriculum. Surgical staff should be aware of the risk that spirit-based skin preparation fluids pose and should take action to minimise the chance of fire occurring.

  12. Development of new index for forest fire risk using satellite images in Indonesia through the direct spectral measurements of soil

    Science.gov (United States)

    Hashimoto, A.; Akita, M.; Takahashi, Y.; Suzuki, H.; Hasegawa, Y.; Ogino, Y.; Naruse, N.; Takahashi, Y.

    2016-12-01

    In recent years, the smoke caused by the forest fires in Indonesia has become a serious problem. Most of the land in Indonesia is covered with peat moss, which occurs the expanding of fires due to the burning itself. Thus, the surface soil water, reflecting the amount of precipitation in the area, can become the indication of the risk of fires. This study aims to develop a new index reflecting the risk of forest fires in Indonesia using satellite remote sensing through the direct spectral measurements of peat moss soil.We have prepared the peat moss in 7 steps of soil water content measured at an accuracy of ±15 percent (Field pro, WD-3). We obtained spectra between 400nm and 1050nm (Source: halogen lamp, spectroscope: self-made space time, spectral analysis kit) from the peat moss.The obtained spectra show the difference from the previous spectral measurement for the soil in various water content. There are the features, especially, in the wavelength range of ultraviolet (400-450nm) and infrared (530-800nm) as shown in the figure; the more the soil water increases, the lower the reflectance becomes. We have developed a new index using the New deep blue band (433 453nm and NIR band 845 885nm of Landsat 8. The resulting satellite images calculated by our original index appears to reflect the risk of forest fires rather than well-known indices such as Normalized Difference Water Index and Normalized difference Soil Index.In conclusion, we have created a new index that highly reflects to the degree of soil water of a peat soil in Indonesia.

  13. Investigations concerning fire-induced accidents in nuclear facilities

    International Nuclear Information System (INIS)

    Lamuth, P.; Lernout, L.A.; Bonneval, F.; Cottaz, M.

    1996-01-01

    In the context of fire protection in technical buildings of French nuclear facilities, three principles have been adopted: prevention, detection and fire-fighting. Their implementation makes it possible on the one hand to limit the fire ignition and the fire growth, and on the other hand to prevent fire extent which would lead to unavailability of several safety related equipment. Although progress has been made in this direction, the fire risks have still not been eliminated. It is therefore essential to evaluate the fire effects and to assess their consequences. To this end, three main R and D programs have been conducted into fires. Part I sets out the fire PSA methodology used for a 900 MWe PWR. Part II gives an outline of two fire and ventilation computer codes useful for the fire PSA. Finally, part III gives an outline of the tests already performed and those currently under way in the two laboratories of the Institut de Protection et de Surete Nucleaire (IPSN) in order to qualify the codes and provide useful information for the safety assessment. (author)

  14. Fire protection and safety in working with sodium. Pt. 2

    International Nuclear Information System (INIS)

    Foerster, K.; Kremer, K.H.; Wolf, J.

    1978-01-01

    The use of sodium as a heat transfer medium in nuclear plant and the associated development of sodium technology caused the requirement for adapting fire and safety precautions to new conditions of dealing with this liquid. The comparison in the first part of this article of the properties of sodium with those of petrol clarified the different fire characteristics of sodium compared to many other combustible materials and the effects of fires which differ from conventional fires. Based on this, measures for fire precautions and for safety of personnel are introduced. (orig.) [de

  15. Effects of Boron Compounds on the Mechanical and Fire Properties of Wood-chitosan and High-density Polyethylene Composites

    Directory of Open Access Journals (Sweden)

    Guo-Fu Wu

    2014-05-01

    Full Text Available Wood-plastic composites (WPCs represent a growing class of durable, low-maintenance construction materials whose use can decrease dependence on petroleum. High-density polyethylene (HDPE, chitosan (CS, wood flour (WF, boric acid (BA, and borax (BX, as well as maleic anhydride grafted polyethylene (MAPE and polyethylene wax (PE wax, were used to develop a durable wood-plastic composite (WPC using the extrusion method. The effects of boron compounds (3%, 6%, 9%, or 12% by weight BA/BX on the mechanical and fire properties of the WPCs were investigated. Mechanical testing indicated that as the percentage weight of boron compounds increased, the flexural modulus, flexural strength, and tensile strength significantly decreased. Cone calorimeter tests were used to characterize the fire performance of the WPCs, and these results suggested that adding BA/BX compounds to WPCs modestly improved the fire performance. As the percentage weight of BA/BX increased from 3% to 9%, the time to ignition (TTI, heat release rate (HRR, total heat release rate (HRR-Total, smoke production rate (SPR, and specific extinction area (SEA of the WPCs were all reduced.

  16. FIRE-PRAN

    International Nuclear Information System (INIS)

    Waterfall, K.W.

    1991-01-01

    Shell Internationale Petroleum Maatschappij B.V. (SIPM), is a service company in the Royal Dutch/Shell Group of Companies who provides services worldwide (outside of the USA) to Shell Operating Companies. It has defined and recommended for implementation by Shell Companies a policy on safety (Enhanced Safety Management policy) to manage the total safety aspects of all they do, including the design, engineering, installation and operation of their facilities worldwide. This policy affects all activities in such a way as to avoid harm to health of, or injury to employees and others as well as avoiding damage to property. This in turn reflects through specific policies and standards for investment strategy, engineering and operations of facilities. With average Group losses due to major fires and explosion (for each incident over Brit-pounds 100,000) between 1988 and 1990 being of the order of Brit-pounds 28 million, there is an obvious potential to effectively employ fire protection criteria in design. However, Shell need to ensure the cost-effective application of protective measures, but first and foremost it is essential not to jeopardize life or risk damage to the environment. FIRE-PRAN has the possibility to do this efficiently as it is A systematic team approach for identification of all potential fire and explosion hazards and consequences, and a means for developing optimal means of protection for all types of facilities. It should thus be considered as an auditing technique, but one that fits into the overall safe management of activities. This paper discusses the status of development of the FIRE-PRAN technique following its successful application over a number of years to a variety of equipment and installations

  17. Nuclear insurance fire risk

    International Nuclear Information System (INIS)

    Dressler, E.G.

    2001-01-01

    Nuclear facilities operate under the constant risk that radioactive materials could be accidentally released off-site and cause injuries to people or damages to the property of others. Management of this nuclear risk, therefore, is very important to nuclear operators, financial stakeholders and the general public. Operators of these facilities normally retain a portion of this risk and transfer the remainder to others through an insurance mechanism. Since the nuclear loss exposure could be very high, insurers usually assess their risk first-hand by sending insurance engineers to conduct a nuclear insurance inspection. Because a serious fire can greatly increase the probability of an off-site release of radiation, fire safety should be included in the nuclear insurance inspection. This paper reviews essential elements of a facility's fire safety program as a key factor in underwriting nuclear third-party liability insurance. (author)

  18. Disentangling effects of key coarse woody debris fuel properties on its combustion, consumption and carbon gas emissions during experimental laboratory fire

    NARCIS (Netherlands)

    Zhao, Weiwei; van Logtestijn, Richard S.P.; van der Werf, Guido R.; van Hal, Jurgen R.; Cornelissen, Johannes H.C.

    2018-01-01

    Coarse woody debris is a key terrestrial carbon pool, and its turnover through fire plays a fundamental role in global carbon cycling. Coarse dead wood fuel properties, which vary between tree species and wood decay stages, might affect its combustion, consumption and carbon gas emissions during

  19. Safety tests carried out at Cadarache. Sodium fires

    International Nuclear Information System (INIS)

    Fruchard, M.

    1976-01-01

    Safety test on sodium fires developed at the Cadarache Nuclear Centre by the Department of Nuclear Safety, section of safety experiments on radioactivity transfer are conducted in two main directions: analysis of the behavior and thermodynamic consequences of accidental fires, working on the basis of typical experimental results; research and development of methods and equipment to control and if possible extinguish these fires. The most important part of this programme is concerned with the sodium pool fires which would result from the failure of a secondary coolant circuit pipe [fr

  20. Thermodynamic Analysis of Supplementary-Fired Gas Turbine Cycles

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Henriksen, Ulrik Birk; Qvale, Einar Bjørn

    2002-01-01

    This paper presents an analysis of the possibilities for improving the efficiency of an indirectly biomass-fired gas turbine (IBFGT) by supplementary direct gas-firing. The supplementary firing may be based on natural gas, biogas, or pyrolysis gas. {The interest in this cycle arise from a recent...... demonstration of a two-stage gasification process through construction of several plants.} A preliminary analysis of the ideal recuperated Brayton cycle shows that for this cycle any supplementary firing will have a marginal efficiency of unity per extra unit of fuel. The same result is obtained...

  1. Forest fires prevention and limitation of the greenhouse effect

    Directory of Open Access Journals (Sweden)

    2005-01-01

    Full Text Available The contribution of forest fires to the carbon budget and greenhouse effect is examined at global and national (Italian scale and forest management options directed to preventing fires are briefly outlined.

  2. 24 CFR 200.86 - Covenant for fire and other hazard insurance.

    Science.gov (United States)

    2010-04-01

    ... Covenant for fire and other hazard insurance. The mortgage shall contain a covenant binding the mortgagor to maintain fire and extended coverage insurance on the property in accordance with terms and... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Covenant for fire and other hazard...

  3. Climate change and future fire regimes: Examples from California

    Science.gov (United States)

    Keeley, Jon E.; Syphard, Alexandra D.

    2016-01-01

    Climate and weather have long been noted as playing key roles in wildfire activity, and global warming is expected to exacerbate fire impacts on natural and urban ecosystems. Predicting future fire regimes requires an understanding of how temperature and precipitation interact to control fire activity. Inevitably this requires historical analyses that relate annual burning to climate variation. Fuel structure plays a critical role in determining which climatic parameters are most influential on fire activity, and here, by focusing on the diversity of ecosystems in California, we illustrate some principles that need to be recognized in predicting future fire regimes. Spatial scale of analysis is important in that large heterogeneous landscapes may not fully capture accurate relationships between climate and fires. Within climatically homogeneous subregions, montane forested landscapes show strong relationships between annual fluctuations in temperature and precipitation with area burned; however, this is strongly seasonal dependent; e.g., winter temperatures have very little or no effect but spring and summer temperatures are critical. Climate models that predict future seasonal temperature changes are needed to improve fire regime projections. Climate does not appear to be a major determinant of fire activity on all landscapes. Lower elevations and lower latitudes show little or no increase in fire activity with hotter and drier conditions. On these landscapes climate is not usually limiting to fires but these vegetation types are ignition-limited. Moreover, because they are closely juxtaposed with human habitations, fire regimes are more strongly controlled by other direct anthropogenic impacts. Predicting future fire regimes is not rocket science; it is far more complicated than that. Climate change is not relevant to some landscapes, but where climate is relevant, the relationship will change due to direct climate effects on vegetation trajectories, as well as

  4. Climate Change and Future Fire Regimes: Examples from California

    Directory of Open Access Journals (Sweden)

    Jon E. Keeley

    2016-08-01

    Full Text Available Climate and weather have long been noted as playing key roles in wildfire activity, and global warming is expected to exacerbate fire impacts on natural and urban ecosystems. Predicting future fire regimes requires an understanding of how temperature and precipitation interact to control fire activity. Inevitably this requires historical analyses that relate annual burning to climate variation. Fuel structure plays a critical role in determining which climatic parameters are most influential on fire activity, and here, by focusing on the diversity of ecosystems in California, we illustrate some principles that need to be recognized in predicting future fire regimes. Spatial scale of analysis is important in that large heterogeneous landscapes may not fully capture accurate relationships between climate and fires. Within climatically homogeneous subregions, montane forested landscapes show strong relationships between annual fluctuations in temperature and precipitation with area burned; however, this is strongly seasonal dependent; e.g., winter temperatures have very little or no effect but spring and summer temperatures are critical. Climate models that predict future seasonal temperature changes are needed to improve fire regime projections. Climate does not appear to be a major determinant of fire activity on all landscapes. Lower elevations and lower latitudes show little or no increase in fire activity with hotter and drier conditions. On these landscapes climate is not usually limiting to fires but these vegetation types are ignition-limited. Moreover, because they are closely juxtaposed with human habitations, fire regimes are more strongly controlled by other direct anthropogenic impacts. Predicting future fire regimes is not rocket science; it is far more complicated than that. Climate change is not relevant to some landscapes, but where climate is relevant, the relationship will change due to direct climate effects on vegetation

  5. Analyzing post-fire topography at the hillslope-channel interface with terrestrial LiDAR: contrasting geomorphic responses from the 2012 Waldo Canyon Fire of Colorado and the 2013 Springs Fire of California

    Science.gov (United States)

    Storesund, R.; Chin, A.; Florsheim, J. L.; O'Hirok, L.; Williams, K.; Austin, K. E.

    2014-12-01

    Mountains areas are increasingly susceptible to wildfires because of warming climates. Although knowledge of the hydro-geomorphological impacts of wildfire has advanced in recent years, much is still unknown regarding how environmental fluxes move through burned watersheds. Because of the loss of vegetation and hydrophobic soils, flash floods often accompany elevated runoff events from burned watersheds, making direct process measurements challenging. Direct measurements are also only partly successful at capturing the spatial variations of post-fire effects. Coupled with short temporal windows for observing such responses, opportunities are often missed for collecting data needed for developing predictive models. Terrestrial LiDAR scanning (TLS) of burned areas allows detailed documentation of the post-fire topography to cm-level accuracy, providing pictures of geomorphic responses not previously possible. This paper reports a comparative study of hillslope-channel interactions, using repeat TLS, in two contrasting environments. Burned by the 2012 Waldo Canyon Fire and 2013 Springs Fire, in Colorado and California respectively, the study sites share many similarities including steep erosive slopes, small drainage areas, and step-pool channel morphologies. TLS provided a tool to test the central hypothesis that, dry ravel, distinct in the California Mediterranean environment, would prompt a greater sedimentological response from the Springs Fire compared to the Waldo Canyon Fire. At selected sites in each area, TLS documented baseline conditions immediately following the fire. Repeat scanning after major storms allowed detection of changes in the landscape. Results show a tendency for sedimentation in river channels in the study sites interacting with dry ravel on hillslopes, whereas erosion dominated the response from the Waldo Canyon Fire with an absence of dry ravel. These data provide clues to developing generalizations for post-fire effects at regional scales

  6. The Calculation and Design of Fire suppression system in the proton accelerator research center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Cho, J. H.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Joo, H. G.

    2010-01-01

    The fire protection system is composed of various fire suppression systems and fire detection and alarm systems. The primary function of the fire protection system is to protect life and property from a fire through detecting fires quickly and suppressing those fires that occur. In this paper, we described the fire suppression system only. The fire suppression system capacity for fire hydrant, the water mist system, sprinkler system and clean agent system is calculated and designed in compliance with the applicable Korean Acts that are applicable to fire protection and the NFSC code

  7. Intumescent paint as fire protection coating

    Directory of Open Access Journals (Sweden)

    R. B. R.S. OLIVEIRA

    Full Text Available Abstract This paper is a compendium on intumescent paint and its main features regarding chemical composition, thermophysical properties and performance as a fire-retardant material. Some of the main technical publications and lines of research on the subject are presented herein. The purpose of this paper is to show the current stage of the technical research being conducted on the topic and enable a better understanding of this fire-retardant material.

  8. Fire-induced risk in Andisols: An State-of-the-Art

    Science.gov (United States)

    Neris, Jonay; Cerdà, Artemi; Santamarta, Juan C.; Doerr, Stefan

    2014-05-01

    Wildfires are increasingly recognized as the primary natural hazard affecting forests and woodlands (Pausas, 2004), and changing the soil properties due to the heat (Aznar et al., 2013). They are also the factor that determines the increase in soil and water losses (Cerdà, 1998a; Shakesby, 2011). Fire contributes to increase the surface runoff due to the water repellency (Mataix-Solera et al., 2004; Cerdà and Doerr, 2008) although a quick recovery is found when vegetation is recovered (Cerdà, 1988b; Guénon et al., 2013). Within the recovery process ash is the key factor once the vegetation is recovered (Bodí et al., 2011; León et al., 2013; Pereira et al., 2013). To reduce the impact of forest fires some strategies were developed (Prats et al., 2013). The fire direct and indirect impacts on ecosystems and the human population, infrastructures, supplies and goods have been increasing over the last decades due to climatic and socio-economic changes and are projected to increase further in the future. In the densely populated volcanic regions that are characterized by steep and fire-prone slopes, Andisols are the main soil type. Their mineralogical properties provide them with specific chemical and physical properties which strength their fertility and resistance to erosion but also differentiate their response to environmental disturbances such as land use change (Jiménez et al., 2006; Neris et al., 2012) but also forest fires and agricultural burning (Neris et al., 2013; Poulenard et al., 2001). Despite their relevance for human development and safety, little specific knowledge exists about them and papers addressing their singularities are limited. This works seeks to compile and review existing scientific works focused on the effects of fire on this particular type of soils, evaluate their response to this disturbance and identify knowledge gaps related to the fire-induced risk in Andisols in order to develop new lines of research. Acknowledgements This

  9. Fire history, effects and management in southern Nevada [Chapter 5

    Science.gov (United States)

    Mathew L. Brooks; Jeanne C. Chambers; Randy A. McKinley

    2013-01-01

    Fire can be both an ecosystem stressor (Chapter 2) and a critical ecosystem process, depending on when, where, and under what conditions it occurs on the southern Nevada landscape. Fire can also pose hazards to human life and property, particularly in the wildland/urban interface (WUI). The challenge faced by land managers is to prevent fires from occurring where they...

  10. Instrumentation for mine safety: fire and smoke problems and solutions

    International Nuclear Information System (INIS)

    Stevens, R.B.

    1982-01-01

    Underground fires continue to be one of the most serious hazards to life and property in the mining industry. Although underground mines are analogous to high-rise buildings where persons are isolated from immediate escape or rescue, application of technology to locate and control fire hazards while still in their controllable state is slow to be implemented in underground mines. This paper describes several USBM (Bureau of Mines) safety programs which included in-mine testing with mine fire and smoke sensors, telemetry and instrumentation to develop recommendations for improving mine fire safety. It is hoped that the technology developed during these programs can be added to other programs to provide the mining industry with the necessary fire safety facts. By recognizing fire potentials and being provided with cost-effective, proven components that will perform reliably under the poor environmental conditions of mining, mine operators can provide protection for their working life and property equal to that which they provide for themselves and their families at home. The basis of this report is two USBM programs for fire protection in metal and nonmetal mines and one coal program. The data was collected beginning in May 1974 and continuing through the present with underground tests of a South African fire system installed at Magma Mine in Superior, Arizona, and a computer-assisted, experimental system at Peabody Coal Mine in Pawnee, Illinois

  11. Electrical Switchgear Building No. 5010-ESF Fire Hazards Technical Report

    International Nuclear Information System (INIS)

    N.M. Ruonavaara

    2001-01-01

    The purpose of this Fire Hazards Analysis Technical Report (hereinafter referred to as Technical Report) is to assess the risk from fire within individual fire areas to ascertain whether the U.S. Department of Energy (DOE) fire safety objectives are met. The objectives, identified in DOE Order 420.1, Change 2, Fire Safety, Section 4.2, establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire or related event; (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of the employees, the public, and the environment; (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards; (4) Property losses from a fire and related events exceeding defined limits established by DOE; and (5) Critical process controls and safety class systems being damaged as a result of a fire and related event

  12. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-01-01

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  13. Properties of fly ash and metakaolín based geopolymer panels under fire resistance tests

    Directory of Open Access Journals (Sweden)

    Luna-Galiano, Y.

    2015-09-01

    Full Text Available This paper presents the results of a study about the effect of fire on geopolymer paste composed of fly ashes, metakaolin and sodium silicate. 2 cm thick, 28 cm high and 18 cm wide panels were filled with the paste obtained. After 28 days of curing at 20 °C and 45% of relative humidity, different tests were carried out in the geopolymers: physico-chemical (density, water absorption, porosity, mechanical (flexural and compressive strength, fire resistance and environmental (leaching and radioactivity. The panels manufactured have been compared with other commercial panels in order to determine the recycling possibilities of fly ashes in manufacturing new fire-insulating geopolymers. The panels obtained can be utilized for the production of interior wall materials, with a good physical, mechanical, fire resistant properties without any environmental problem.Este documento presenta los resultados de un estudio sobre el efecto del fuego sobre pastas de geopolímeros compuestas de cenizas volantes, metacaolín y silicato sódico. Con la pasta obtenida se han rellenado paneles de dimensiones 2 cm de espesor, 28 cm de altura y 18 cm de ancho. Tras 28 días de curado a 20 °C y un 45% de humedad relativa, diferentes ensayos fueron realizados en los geopolímeros obtenidos: fisicoquímicos (densidad, absorción de agua, porosidad, mecánicos (resistencia a compresión y a flexión, de resistencia al fuego y medioambientales (lixiviación y radioactividad. Los paneles fabricados han sido comparados con paneles comerciales para determinar las posibilidades de reciclaje de las cenizas volantes para la fabricación de nuevos productos geopoliméricos con propiedades aislantes al fuego. Los paneles obtenidos pueden ser utilizados para la producción de paredes interiores, con buenas propiedades físicas, mecánicas y de resistencia al fuego sin ningún problema medioambiental.

  14. Parametric study for the fire safety design of steel structures

    DEFF Research Database (Denmark)

    Aiuti, Riccardo; Giuliani, Luisa

    2013-01-01

    the considered time of fire exposure. A deeper knowledge on the failure mode of steel structure is however important in order to ensure the safety of the people and properties outside the building. Aim of this paper is to analyze the behaviour of single elements, sub-assemblies and frames exposed to fire...... or hindered thermal expansion induced on the element by the rest of the structure. Nevertheless, restrained thermal expansion is known to significantly affect the behaviour of steel structures in fire, and the compliance with a prescribed resistance class doesn’t ensure the integrity of the building after...... and find out the basic collapse mechanisms of structural elements in fire conditions, considering the rest of the construction with appropriate constraints. The analysis is carried out taking into account material and geometrical nonlinearities as well as the degradation of steel properties at high...

  15. Liquid nitrogen fire extinguishing system test report

    International Nuclear Information System (INIS)

    Beidelman, J.A.

    1972-01-01

    The objective of this test series was to demonstrate the feasibility of using liquid nitrogen as a fire-extinguishing agent for certain types of metal fires. It was intended to provide data and experience appropriate to the design of a second series which will test the applicability of this technique to plutonium fires and which will develop more detailed operating information and permit more precise measurement of test parameters-oxygen depletion rates and equilibrium concentrations, temperature effects, and nitrogen pressures, flow rates, spray methods and patterns, etc. The test series was directed specifically toward extinguishment of metal fires occurring in well-confined areas and was not intended to be representative of any larger classification. Fires of several types were tested, e.g., magnesium, mixed magnesium and zirconium, sodium and cerium

  16. GASIFICATION BASED BIOMASS CO-FIRING - PHASE I

    Energy Technology Data Exchange (ETDEWEB)

    Babul Patel; Kevin McQuigg; Robert F. Toerne

    2001-12-01

    Biomass gasification offers a practical way to use this locally available fuel source for co-firing traditional large utility boilers. The gasification process converts biomass into a low Btu producer gas that can be fed directly into the boiler. This strategy of co-firing is compatible with variety of conventional boilers including natural gas fired boilers as well as pulverized coal fired and cyclone boilers. Gasification has the potential to address all problems associated with the other types of co-firing with minimum modifications to the existing boiler systems. Gasification can also utilize biomass sources that have been previously unsuitable due to size or processing requirements, facilitating a reduction in the primary fossil fuel consumption in the boiler and thereby reducing the greenhouse gas emissions to the atmosphere.

  17. La Crema: A case study of mutual fire insurance

    OpenAIRE

    Antonio Cabrales; Antoni Calvó; Matthew O. Jackson

    2000-01-01

    We analyze a mutual fire insurance mechanism used in Andorra, which is called La Crema in the local language. This mechanism relies on households' announced property values to determine how much a household is reimbursed in the case of a fire and how payments are apportioned among other households. The only Pareto-efficient al- location reachable through the mechanism requires that all house- holds honestly report the true value of their property. However, such honest reporting is not an equi...

  18. Healthcare costs of burn patients from homes without fire sprinklers.

    Science.gov (United States)

    Banfield, Joanne; Rehou, Sarah; Gomez, Manuel; Redelmeier, Donald A; Jeschke, Marc G

    2015-01-01

    The treatment of burn injuries requires high-cost services for healthcare and society. Automatic fire sprinklers are a preventive measure that can decrease fire injuries, deaths, property damage, and environmental toxins. This study's aim was to conduct a cost analysis of patients with burn or inhalation injuries caused by residential fires and to compare this with the cost of implementing residential automatic fire sprinklers. We conducted a cohort analysis of adult burn patients admitted to our provincial burn center (1995-2012). Patient demographics and injury characteristics were collected from medical records and clinical and coroner databases. Resource costs included average cost per day at our intensive care and rehabilitation program, transportation, and property loss. During the study period, there were 1557 residential fire-related deaths province-wide and 1139 patients were admitted to our provincial burn center as a result of a flame injury occurring at home. At our burn center, the average cost was CAN$84,678 per patient with a total cost of CAN$96,448,194. All resources totaled CAN$3,605,775,200. This study shows the considerable healthcare costs of burn patients from homes without fire sprinklers.

  19. Fire hazard analysis of the radioactive mixed waste trenchs

    International Nuclear Information System (INIS)

    McDonald, K.M.

    1995-01-01

    This Fire Hazards Analysis (FHA) is intended to assess comprehensively the risk from fire associated with the disposal of low level radioactive mixed waste in trenches within the lined landfills, provided by Project W-025, designated Trench 31 and 34 of the Burial Ground 218-W-5. Elements within the FHA make recommendations for minimizing risk to workers, the public, and the environment from fire during the course of the operation's activity. Transient flammables and combustibles present that support the operation's activity are considered and included in the analysis. The graded FHA contains the following elements: description of construction, protection of essential safety class equipment, fire protection features, description of fire hazards, life safety considerations, critical process equipment, high value property, damage potential--maximum credible fire loss (MCFL) and maximum possible fire loss (MPFL), fire department/brigade response, recovery potential, potential for a toxic, biological and/or radiation incident due to a fire, emergency planning, security considerations related to fire protection, natural hazards (earthquake, flood, wind) impact on fire safety, and exposure fire potential, including the potential for fire spread between fire areas. Recommendations for limiting risk are made in the text of this report and printed in bold type. All recommendations are repeated in a list in Section 18.0

  20. Advanced technique for computing fuel combustion properties in pulverized-fuel fired boilers

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R. (Vsesoyuznyi Teplotekhnicheskii Institut (Russian Federation))

    1992-03-01

    Reviews foreign technical reports on advanced techniques for computing fuel combustion properties in pulverized-fuel fired boilers and analyzes a technique developed by Combustion Engineering, Inc. (USA). Characteristics of 25 fuel types, including 19 grades of coal, are listed along with a diagram of an installation with a drop tube furnace. Characteristics include burn-out intensity curves obtained using thermogravimetric analysis for high-volatile bituminous, semi-bituminous and coking coal. The patented LFP-SKM mathematical model is used to model combustion of a particular fuel under given conditions. The model allows for fuel particle size, air surplus, load, flame height, and portion of air supplied as tertiary blast. Good agreement between computational and experimental data was observed. The method is employed in designing new boilers as well as converting operating boilers to alternative types of fuel. 3 refs.

  1. 24 CFR 242.33 - Covenant for malpractice, fire, and other hazard insurance.

    Science.gov (United States)

    2010-04-01

    ... for malpractice, fire, and other hazard insurance. The mortgage shall contain a covenant binding the mortgagor to maintain adequate liability, fire, and extended coverage insurance on the property. The... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Covenant for malpractice, fire, and...

  2. Intumescent Coatings as Fire Retardants

    Science.gov (United States)

    Parker, J. A.; Fohlen, G. M.; Sawko, P. M.; Fish, R. H.

    1970-01-01

    The development of fire-retardant coatings to protect surfaces which may be exposed to fire or extreme heat is a subject of intense interest to many industries. A fire-retardant paint has been developed which represents a new chemical approach for preparing intumescent coatings, and potentially, is very important to fire-prevention authorities. The requirements for a superior coating include ease of application, suitability to a wide variety of surfaces and finishes, and stability over an extended period of time within a broad range of ambient temperature and humidity conditions. These innovative coatings, when activated by the heat of a fire, react to form a thick, low-density, polymeric coating or char layer. Water vapor and sulphur dioxide are released during the intumescent reaction. Two fire-protection mechanisms thus become available: (1) the char layer retards the flow of heat, due to the extremely low thermal conductivity; and (2) water vapor and sulfur dioxide are released, providing fire quenching properties. Still another mechanism functions in cases where the char, by virtue of its high oxidation resistance and low thermal conductivity, reaches a sufficiently high temperature to re-radiate much of the incident heat load. The coatings consist of dispersions of selective salts of a nitro-amino-arornatic compound. Specifically, para-nitroaniline bisulfate and the ammonium salt of para-nitroaniline-ortho sulphuric acid (2-amino-5-nitrobenzenesulphuric acid) are used. Suitable vehicles are cellulose nitrate of lacquer grade, a nitrite-phenolic modified rubber, or epoxy-polysulfide copolymer. Three separate formulations have been developed. A solvent is usually employed, such as methylethyl ketone, butyl acetate, or toluene, which renders the coatings suitably thin and which evaporates after the coatings are applied. Generally, the intumescent material is treated as insoluble in the vehicle, and is ground and dispersed in the vehicle and solvent like an

  3. The calcium-binding protein parvalbumin modulates the firing 1 properties of the reticular thalamic nucleus bursting neurons.

    Science.gov (United States)

    Albéri, Lavinia; Lintas, Alessandra; Kretz, Robert; Schwaller, Beat; Villa, Alessandro E P

    2013-06-01

    The reticular thalamic nucleus (RTN) of the mouse is characterized by an overwhelming majority of GABAergic neurons receiving afferences from both the thalamus and the cerebral cortex and sending projections mainly on thalamocortical neurons. The RTN neurons express high levels of the "slow Ca(2+) buffer" parvalbumin (PV) and are characterized by low-threshold Ca(2+) currents, I(T). We performed extracellular recordings in ketamine/xylazine anesthetized mice in the rostromedial portion of the RTN. In the RTN of wild-type and PV knockout (PVKO) mice we distinguished four types of neurons characterized on the basis of their firing pattern: irregular firing (type I), medium bursting (type II), long bursting (type III), and tonically firing (type IV). Compared with wild-type mice, we observed in the PVKOs the medium bursting (type II) more frequently than the long bursting type and longer interspike intervals within the burst without affecting the number of spikes. This suggests that PV may affect the firing properties of RTN neurons via a mechanism associated with the kinetics of burst discharges. Ca(v)3.2 channels, which mediate the I(T) currents, were more localized to the somatic plasma membrane of RTN neurons in PVKO mice, whereas Ca(v)3.3 expression was similar in both genotypes. The immunoelectron microscopy analysis showed that Ca(v)3.2 channels were localized at active axosomatic synapses, thus suggesting that the differential localization of Ca(v)3.2 in the PVKOs may affect bursting dynamics. Cross-correlation analysis of simultaneously recorded neurons from the same electrode tip showed that about one-third of the cell pairs tended to fire synchronously in both genotypes, independent of PV expression. In summary, PV deficiency does not affect the functional connectivity between RTN neurons but affects the distribution of Ca(v)3.2 channels and the dynamics of burst discharges of RTN cells, which in turn regulate the activity in the thalamocortical circuit.

  4. Ten Years of Post-Fire Vegetation Recovery following the 2007 Zaca Fire using Landsat Satellite Imagery

    Science.gov (United States)

    Hallett, J. K. E.; Miller, D.; Roberts, D. A.

    2017-12-01

    Forest fires play a key role in shaping eco-systems. The risk to vegetation depends on the fire regime, fuel conditions (age and amount), fire temperature, and physiological characteristics such as bark thickness and stem diameter. The 2007 Zaca Fire (24 kilometers NE of Buellton, Santa Barbara County, California) burned 826.4 km2 over the course of 2 months. In this study, we used a time series of Landsat 5 Thematic Mapper and Landsat 8 Operational Land Imager imagery, to evaluate plant burn severity and post fire recovery as defined into classes of above average recovery, normal recovery, and below average recovery. We spectrally unmixed the images into green vegetation (GV), non-photosynthetic vegetation (NPV), soil surface (SOIL), and ash with a spectral library developed using Constrained Reference Endmember Selection (CRES). We delineated the fire perimeter using the differenced Normalized Burn Ratio (dNBR) and evaluated changes in this index and the Normalized Difference Vegetation Index through time. The results showed an immediate decline in GV and NPV fractions, with a rise in soil and ash fractions directly following the fire, with a slow recovery in GV fraction and a loss of bare soil cover. The was a sharp increase in the ash fraction following the fire and gradual decrease in the year after. Most areas have recovered as of 2017, with prominent recovery in the center of the burn scar and reduced recovery in areas to the south. These results indicate how post-fire vegetation varies based on initial burn severity and pre-fire GV and NPV fractions.

  5. Mechanical Properties and Microstructure of Fast – Fired Clinker Tiles Based on Wierzbka I Raw Material

    OpenAIRE

    Gajek M.; Rapacz-Kmita A.; Dudek M.; Partyka J.

    2016-01-01

    The article presents results of research on microstructural and mechanical properties of floor tiles clinker manufactured on the basis of Wierzbka I raw material, which is part of the deposit Wierzbka, near Suchedniów. Wierzbka I clay was added in various volume fractions to the standard tile compositions used in industrial practice. The samples were pressed in a range of from 21 MPa to 42 MPa and fired in the laboratory furnace at 1130°C to 1190°C. Selected compositions were pressed at 28 MP...

  6. Repos, fire sales, and bankruptcy policy

    OpenAIRE

    Antinolfi, Gaetano; Carapella, Francesca; Kahn, Charles; Martin, Antoine; Mills, David; Nosal, Ed

    2012-01-01

    The events from the 2007-2009 financial crisis have raised concerns that the failure of large financial institutions can lead to destabilizing fire sales of assets. The risk of fire sales is related to exemptions from bankruptcy's automatic stay provision enjoyed by a number of financial contracts, such as repo. An automatic stay prohibits collection actions by creditors against a bankrupt debtor or his property. It prevents a creditor from liquidating collateral of a defaulting debtor since ...

  7. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  8. Theoretical-probability evaluation of the fire hazard of coal accumulations

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, F F

    1978-01-01

    An evaluation is suggested for the fire hazard of coal accumulations, based on determining the probability of an endogenic fire. This probability is computed by using the statistical characteristics of the temperature distribution of spontaneous heating in large accumulations, and the criteria of Gluzberg's fire hazard that is determined by the coal's physico-chemical properties, oxygen concentration, and the size of the accumulations. 4 references.

  9. Numerical Modelling of Fire-Atmosphere Interactions and the 2003 Canberra Bushfires

    Science.gov (United States)

    Simpson, C.; Sturman, A.; Zawar-Reza, P.

    2010-12-01

    It is well known that the behaviour of a wildland fire is strongly associated with the conditions of its surrounding atmosphere. However, the two-way interactions between fire behaviour and the atmospheric conditions are not well understood. A numerical model is used to simulate wildland fires so that the nature of these fire-atmosphere interactions, and how they might affect fire behaviour, can be further investigated. The 2003 Canberra bushfires are used as a case study due to their highly destructive and unusual behaviour. On the 18th January 2003, these fires spread to the urban suburbs of Canberra, resulting in the loss of four lives and the destruction of over 500 homes. Fire-atmosphere interactions are believed to have played an important role in making these fires so destructive. WRF-Fire is used to perform real data simulations of the 2003 Canberra bushfires. WRF-Fire is a coupled fire-atmosphere model, which combines a semi-empirical fire spread model with an atmospheric model, allowing it to directly simulate the two-way interactions between a fire and its surrounding atmosphere. These simulations show the impact of the presence of a fire on conditions within the atmospheric boundary layer. This modification of the atmosphere, resulting from the injection of heat and moisture released by the fire, appears to have a direct feedback onto the overall fire behaviour. The bushfire simulations presented in this paper provide important scientific insights into the nature of fire-atmosphere interactions for a real situation. It is expected that they will also help fire managers in Australia to better understand why the 2003 Canberra bushfires were so destructive, as well as to gain improved insight into bushfire behaviour in general.

  10. Fire Hazard Analysis for the Cold Vacuum Drying facility (CVD) Facility

    Energy Technology Data Exchange (ETDEWEB)

    SINGH, G.

    2000-09-06

    The CVDF is a nonreactor nuclear facility that will process the Spent Nuclear Fuels (SNF) presently stored in the 105-KE and 105-KW SNF storage basins. Multi-canister overpacks (MCOs) will be loaded (filled) with K Basin fuel transported to the CVDF. The MCOs will be processed at the CVDF to remove free water from the fuel cells (packages). Following processing at the CVDF, the MCOs will be transported to the CSB for interim storage until a long-term storage solution can be implemented. This operation is expected to start in November 2000. A Fire Hazard Analysis (FHA) is required for all new facilities and all nonreactor nuclear facilities, in accordance with U.S. Department of Energy (DOE) Order 5480.7A, Fire Protection. This FHA has been prepared in accordance with DOE 5480.7A and HNF-PRO-350, Fire Hazard Analysis Requirements. Additionally, requirements or criteria contained in DOE, Richland Operations Office (RL) RL Implementing Directive (RLID) 5480.7, Fire Protection, or other DOE documentation are cited, as applicable. This FHA comprehensively assesses the risk of fire at the CVDF to ascertain whether the specific objectives of DOE 5480.7A are met. These specific fire protection objectives are: (1) Minimize the potential for the occurrence of a fire. (2) Ensure that fire does not cause an onsite or offsite release of radiological and other hazardous material that will threaten the public health and safety or the environment. (3) Establish requirements that will provide an acceptable degree of life safety to DOE and contractor personnel and ensure that there are no undue hazards to the public from fire and its effects in DOE facilities. (4) Ensure that vital DOE programs will not suffer unacceptable delays as a result of fire and related perils. (5) Ensure that property damage from fire and related perils does not exceed an acceptable level. (6) Ensure that process control and safety systems are not damaged by fire or related perils. This FHA is based on the

  11. Fire Hazard Analysis for the Cold Vacuum Drying facility (CVD) Facility

    International Nuclear Information System (INIS)

    SINGH, G.

    2000-01-01

    The CVDF is a nonreactor nuclear facility that will process the Spent Nuclear Fuels (SNF) presently stored in the 105-KE and 105-KW SNF storage basins. Multi-canister overpacks (MCOs) will be loaded (filled) with K Basin fuel transported to the CVDF. The MCOs will be processed at the CVDF to remove free water from the fuel cells (packages). Following processing at the CVDF, the MCOs will be transported to the CSB for interim storage until a long-term storage solution can be implemented. This operation is expected to start in November 2000. A Fire Hazard Analysis (FHA) is required for all new facilities and all nonreactor nuclear facilities, in accordance with U.S. Department of Energy (DOE) Order 5480.7A, Fire Protection. This FHA has been prepared in accordance with DOE 5480.7A and HNF-PRO-350, Fire Hazard Analysis Requirements. Additionally, requirements or criteria contained in DOE, Richland Operations Office (RL) RL Implementing Directive (RLID) 5480.7, Fire Protection, or other DOE documentation are cited, as applicable. This FHA comprehensively assesses the risk of fire at the CVDF to ascertain whether the specific objectives of DOE 5480.7A are met. These specific fire protection objectives are: (1) Minimize the potential for the occurrence of a fire. (2) Ensure that fire does not cause an onsite or offsite release of radiological and other hazardous material that will threaten the public health and safety or the environment. (3) Establish requirements that will provide an acceptable degree of life safety to DOE and contractor personnel and ensure that there are no undue hazards to the public from fire and its effects in DOE facilities. (4) Ensure that vital DOE programs will not suffer unacceptable delays as a result of fire and related perils. (5) Ensure that property damage from fire and related perils does not exceed an acceptable level. (6) Ensure that process control and safety systems are not damaged by fire or related perils. This FHA is based on the

  12. FIRE

    International Nuclear Information System (INIS)

    Brtis, J.S.; Hausheer, T.G.

    1990-01-01

    FIRE, a microcomputer based program to assist engineers in reviewing and documenting the fire protection impact of design changes has been developed. Acting as an electronic consultant, FIRE is designed to work with an experienced nuclear system engineer, who may not have any detailed fire protection expertise. FIRE helps the engineer to decide if a modification might adversely affect the fire protection design of the station. Since its first development, FIRE has been customized to reflect the fire protection philosophy of the Commonwealth Edison Company. That program is in early production use. This paper discusses the FIRE program in light of its being a useful application of expert system technologies in the power industry

  13. Broadleaf deciduous forest counterbalanced the direct effect of climate on Holocene fire regime in hemiboreal/boreal region (NE Europe)

    Science.gov (United States)

    Feurdean, Angelica; Veski, Siim; Florescu, Gabriela; Vannière, Boris; Pfeiffer, Mirjam; O'Hara, Robert B.; Stivrins, Normunds; Amon, Leeli; Heinsalu, Atko; Vassiljev, Jüri; Hickler, Thomas

    2017-08-01

    Disturbances by fire are essential for the functioning of boreal/hemiboreal forests, but knowledge of long-term fire regime dynamics is limited. We analysed macrocharcoal morphologies and pollen of a sediment record from Lake Lielais Svētiņu (eastern Latvia), and in conjunction with fire traits analysis present the first record of Holocene variability in fire regime, fuel sources and fire types in boreal forests of the Baltic region. We found a phase of moderate to high fire activity during the cool and moist early (mean fire return interval; mFRI of ∼280 years; 11,700-7500 cal yr BP) and the late (mFRI of ∼190 years; 4500-0 cal yr BP) Holocene and low fire activity (mFRI of ∼630 years) during the Holocene Thermal Optimum (7500-4500 cal yr BP). Charcoal morphotypes and the pollen record show the predominance of frequent surface fires, occasionally transitioning to the crown during Pinus sylvestris-Betula boreal forests and less frequent surface fires during the dominance of temperate deciduous forests. In contrast to the prevailing opinion that fires in boreal forests are mostly low to moderate severity surface fires, we found evidence for common occurrence of stand-replacing crown fires in Picea abies canopy. Our results highlight that charcoal morphotypes analysis allows for distinguishing the fuel types and surface from crown fires, therefore significantly advancing our interpretation of fire regime. Future warmer temperatures and increase in the frequency of dry spells and abundant biomass accumulation can enhance the fire risk on the one hand, but will probably promote the expansion of broadleaf deciduous forests to higher latitudes, on the other hand. By highlighting the capability of broadleaf deciduous forests to act as fire-suppressing landscape elements, our results suggest that fire activity may not increase in the Baltic area under future climate change.

  14. A Review of Fire Interactions and Mass Fires

    Directory of Open Access Journals (Sweden)

    Mark A. Finney

    2011-01-01

    Full Text Available The character of a wildland fire can change dramatically in the presence of another nearby fire. Understanding and predicting the changes in behavior due to fire-fire interactions cannot only be life-saving to those on the ground, but also be used to better control a prescribed fire to meet objectives. In discontinuous fuel types, such interactions may elicit fire spread where none otherwise existed. Fire-fire interactions occur naturally when spot fires start ahead of the main fire and when separate fire events converge in one location. Interactions can be created intentionally during prescribed fires by using spatial ignition patterns. Mass fires are among the most extreme examples of interactive behavior. This paper presents a review of the detailed effects of fire-fire interaction in terms of merging or coalescence criteria, burning rates, flame dimensions, flame temperature, indraft velocity, pulsation, and convection column dynamics. Though relevant in many situations, these changes in fire behavior have yet to be included in any operational-fire models or decision support systems.

  15. Fires in rooms containing electrical components - incident planning, fire fighting tactics, risks

    International Nuclear Information System (INIS)

    Magnusson, Tommy; Ottosson, Jan; Lindskog, BertiI; Soederquist Bende, Evy; Eriksson, Fredrik; Haffling, Stefan

    2006-12-01

    On July 1, 2005 a fire occurred within an electrical switch room at Forsmark Nuclear Power Plant. At the evaluation of the incident it was identified that the pre-fire plans did not give sufficient information in order to make the appropriate decisions. Questions raised based on the incident are how decisions are made and orders are delegated with respect to the incident command, which fire fighting tactic should be used, which types of extinguishing media should be used, what are the risks with respect to safety of staff and safety of the reactor. Lessons learned from the fire at Forsmark were that pre-incident planning was at hand but the information was not sufficient to make the correct initial decisions that might be critical for life and property. One of the most crucial ingredients in all safety related work is to utilize previous experience in order to maintain a high degree of safety. Lessons learnt are also the foundation on which the ability to construct or create strong barriers against a certain fault phenomena, fault mechanism or type of initial event. In the case of nuclear processes, fire is considered as an important and critical initial event which has to be recognized in a number of cases in order to maintain a safe process. The likelihood for a fire to represent an initial event should not be underestimated and can therefore not be neglected, probabilistically or deterministically, unless the inherent safety systems can not control the event in an acceptable manner. Regardless of safety measures and lessons learnt from previous experiences in the construction and the operation of the nuclear facility, fires can occur. Previous experiences point out that process system, e.g. systems that are part of the turbine, are more frequently subject to fire incidents compared to ordinary safety systems. Fires in electrical components, often electrical cabinets, can be difficult to handle and to extinguish quickly. This report presents the background work

  16. Quantitative analysis of forest fire extinction efficiency

    Directory of Open Access Journals (Sweden)

    Miguel E. Castillo-Soto

    2015-08-01

    Full Text Available Aim of study: Evaluate the economic extinction efficiency of forest fires, based on the study of fire combat undertaken by aerial and terrestrial means. Area of study, materials and methods: Approximately 112,000 hectares in Chile. Records of 5,876 forest fires that occurred between 1998 and 2009 were analyzed. The area further provides a validation sector for results, by incorporating databases for the years 2010 and 2012. The criteria used for measuring extinction efficiency were economic value of forestry resources, Contraction Factor analysis and definition of the extinction costs function. Main results: It is possible to establish a relationship between burnt area, extinction costs and economic losses. The method proposed may be used and adapted to other fire situations, requiring unit costs for aerial and terrestrial operations, economic value of the property to be protected and speed attributes of fire spread in free advance. Research highlights: The determination of extinction efficiency in containment works of forest fires and potential projection of losses, different types of plant fuel and local conditions favoring the spread of fire broaden the admissible ranges of a, φ and Ce considerably.

  17. Probabilistic analysis of fires in nuclear plants

    International Nuclear Information System (INIS)

    Unione, A.; Teichmann, T.

    1985-01-01

    The aim of this paper is to describe a multilevel (i.e., staged) probabilistic analysis of fire risks in nuclear plants (as part of a general PRA) which maximizes the benefits of the FRA (fire risk assessment) in a cost effective way. The approach uses several stages of screening, physical modeling of clearly dominant risk contributors, searches for direct (e.g., equipment dependences) and secondary (e.g., fire induced internal flooding) interactions, and relies on lessons learned and available data from and surrogate FRAs. The general methodology is outlined. 6 figs., 10 tabs

  18. Introduction: Strengthening the foundation of wildland fire Effects prediction for research and management

    Science.gov (United States)

    Matthew B. Dickinson; Kevin C. Ryan

    2010-01-01

    As prescribed fire use increases and the options for responding to wildfires continue to expand beyond suppression, the need for improving fire effects prediction capabilities be¬comes increasingly apparent. The papers in this Fire Ecology special issue describe recent advances in fire effects prediction for key classes of direct (first-order) fire effects. Important...

  19. FIRE-RESISTANCE PROPERTIES RESEARCH OF “WATER GLASS - GRAPHITE MICROPARTICLES” COMPOSITE MATERIAL

    Directory of Open Access Journals (Sweden)

    E. A. Pitukhin

    2016-03-01

    Full Text Available Subject of Research. Research results of the fire-resistance for “water glass - graphite microparticles” composite material (CM are given. The method for fire-resistance test of the micro composition is suggested in order to determine the limit state of the experimental samples under hightemperature action. Method. Test-benchequipment being used for research includes metering devices of temperature and time, as well as laboratory electric furnace PL20 with a maximum temperature in the chamber up to 1250ºC. Fire-resistance limit for the test samples of composite material is determined by the loss of insulating ability (I. For that purpose, the time is obtained from the test beginning with the standard temperature mode up to a limiting condition. Main Results. In accordance with the requirements of regulatory documents fire-resistance limit I15 has been obtained equal to 15 minutes. The qualitative and quantitative phase analysis of the CM structure has been done. By the study of samples by X-ray diffraction and electron microscopy we have determined that the material retains the same chemical structure with a monotonic heating above 700° C. Practical Relevance. The composite material with obtained characteristics can be used as a protective coating for building constructions with the aim of fire-resistance enhancement and fuel hazard reduction.

  20. First Order Fire Effects Model: FOFEM 4.0, user's guide

    Science.gov (United States)

    Elizabeth D. Reinhardt; Robert E. Keane; James K. Brown

    1997-01-01

    A First Order Fire Effects Model (FOFEM) was developed to predict the direct consequences of prescribed fire and wildfire. FOFEM computes duff and woody fuel consumption, smoke production, and fire-caused tree mortality for most forest and rangeland types in the United States. The model is available as a computer program for PC or Data General computer.

  1. Cerebellar Shaping of Motor Cortical Firing Is Correlated with Timing of Motor Actions

    Directory of Open Access Journals (Sweden)

    Abdulraheem Nashef

    2018-05-01

    Full Text Available Summary: In higher mammals, motor timing is considered to be dictated by cerebellar control of motor cortical activity, relayed through the cerebellar-thalamo-cortical (CTC system. Nonetheless, the way cerebellar information is integrated with motor cortical commands and affects their temporal properties remains unclear. To address this issue, we activated the CTC system in primates and found that it efficiently recruits motor cortical cells; however, the cortical response was dominated by prolonged inhibition that imposed a directional activation across the motor cortex. During task performance, cortical cells that integrated CTC information fired synchronous bursts at movement onset. These cells expressed a stronger correlation with reaction time than non-CTC cells. Thus, the excitation-inhibition interplay triggered by the CTC system facilitates transient recruitment of a cortical subnetwork at movement onset. The CTC system may shape neural firing to produce the required profile to initiate movements and thus plays a pivotal role in timing motor actions. : Nashef et al. identified a motor cortical subnetwork recruited by cerebellar volley that was transiently synchronized at movement onset. Cerebellar control of cortical firing was dominated by inhibition that shaped task-related firing of neurons and may dictate motor timing. Keywords: motor control, primates, cerebellar-thalamo-cortical, synchrony, noise correlation, reaction time

  2. FIRES: Fire Information Retrieval and Evaluation System - A program for fire danger rating analysis

    Science.gov (United States)

    Patricia L. Andrews; Larry S. Bradshaw

    1997-01-01

    A computer program, FIRES: Fire Information Retrieval and Evaluation System, provides methods for evaluating the performance of fire danger rating indexes. The relationship between fire danger indexes and historical fire occurrence and size is examined through logistic regression and percentiles. Historical seasonal trends of fire danger and fire occurrence can be...

  3. Histone acetylation regulates the time of replication origin firing.

    Science.gov (United States)

    Vogelauer, Maria; Rubbi, Liudmilla; Lucas, Isabelle; Brewer, Bonita J; Grunstein, Michael

    2002-11-01

    The temporal firing of replication origins throughout S phase in yeast depends on unknown determinants within the adjacent chromosomal environment. We demonstrate here that the state of histone acetylation of surrounding chromatin is an important regulator of temporal firing. Deletion of RPD3 histone deacetylase causes earlier origin firing and concurrent binding of the replication factor Cdc45p to origins. In addition, increased acetylation of histones in the vicinity of the late origin ARS1412 by recruitment of the histone acetyltransferase Gcn5p causes ARS1412 alone to fire earlier. These data indicate that histone acetylation is a direct determinant of the timing of origin firing.

  4. Comparative Analysis of Direct and Indirect Property Investment ...

    African Journals Online (AJOL)

    Sultan

    substitute for direct property investment in Abuja, Nigeria. The study .... of stock market investment using Lagos,. Ibadan and ... ordinary shares and saving account for the. Adeogun ... Hence, the need for this study which provides information.

  5. 78 FR 14351 - Wildland Fire Executive Council; Renewal

    Science.gov (United States)

    2013-03-05

    ... to provide advice on the coordinated national level wildland fire policy leadership, direction, and program oversight in support to the Wildland Fire Leadership Council. FOR FURTHER INFORMATION CONTACT: Ms... the Fish and Wildlife Act of 1956 (16 U.S.C. 742a- 742j), the Federal Land Policy and Management Act...

  6. Feasibility study on utilization of palm fibre waste into fired clay brick

    Science.gov (United States)

    Kadir, A. A.; Sarani, N. A.; Zaman, N. N.; Abdullah, Mohd Mustafa Al Bakri

    2017-04-01

    Malaysia is the second largest of palm oil producer after Indonesia, which contribute to 50 % of palm oil production. With this demand, the increasing of palm oil plantation over the years has led to the large production of agricultural waste, for example palm fibre waste. This study investigates different percentages of palm fibre (0 %, 1 %, 5 % and 10 %) to be incorporated into fired clay brick. Manufactured bricks were fired at 1 °C/min heating rate up to 1050 °C. The effects of manufacture bricks on the physical and mechanical properties of manufactured brick were also determined. All brick samples were tested due to the physical and mechanical properties which include dry density, firing shrinkage, initial rate of suction (IRS), water absorption, porosity and compressive strength. Findings show that increasing palm fibre waste affected the properties of brick, which decreased their density, besides increased firing shrinkage, IRS, water absorption, porosity and compressive strength. However, all the manufactured brick still followed the requirement.

  7. Cigarette Fires Involving Upholstered Furniture in Residences: The Role that Smokers, Smoker Behavior, and Fire Standard Compliant Cigarettes Play

    Science.gov (United States)

    Butry, David T.; Thomas, Douglas S.

    2017-01-01

    Residential structure fires pose a significant risk to life and property. A major source of these fires is the ignition of upholstered furniture by cigarettes. It has long been established that cigarettes and other lighted tobacco products could ignite upholstered furniture and were a leading cause of fire deaths in residences. In recent years, states have adopted fire standard compliant cigarettes (‘FSC cigarettes’) that are made with a wrapping paper that contains regularly spaced bands, which increases the likelihood of self-extinguishment. This paper measures the effectiveness of FSC cigarettes on the number of residential fires involving upholstered furniture, and the resulting fatalities, injuries, and extent of flame spread, while accounting for the under-reporting of fire incidents. In total, four models were estimated using fire department data from 2002 to 2011. The results provide evidence that FSC cigarettes, on average, reduced the number of residential fires by 45 %, reduced fatalities by 23 %, and extent of flame spread by 27 % in 2011. No effect on injuries was found. Within each state, effectiveness is moderated by the number of smokers and their consumption patterns. In general, FSC cigarettes are more effective in places with a large smoking population who engage in heavier smoking. There is a very limited effect on the lightest of smokers, suggesting behavioral differences between heavy and light smokers that influence fire risk. PMID:28751788

  8. Fire propagation equation for the explicit identification of fire scenarios in a fire PSA

    International Nuclear Information System (INIS)

    Lim, Ho Gon; Han, Sang Hoon; Moon, Joo Hyun

    2011-01-01

    When performing fire PSA in a nuclear power plant, an event mapping method, using an internal event PSA model, is widely used to reduce the resources used by fire PSA model development. Feasible initiating events and component failure events due to fire are identified to transform the fault tree (FT) for an internal event PSA into one for a fire PSA using the event mapping method. A surrogate event or damage term method is used to condition the FT of the internal PSA. The surrogate event or the damage term plays the role of flagging whether the system/component in a fire compartment is damaged or not, depending on the fire being initiated from a specified compartment. These methods usually require explicit states of all compartments to be modeled in a fire area. Fire event scenarios, when using explicit identification, such as surrogate or damage terms, have two problems: there is no consideration of multiple fire propagation beyond a single propagation to an adjacent compartment, and there is no consideration of simultaneous fire propagations in which an initiating fire event is propagated to multiple paths simultaneously. The present paper suggests a fire propagation equation to identify all possible fire event scenarios for an explicitly treated fire event scenario in the fire PSA. Also, a method for separating fire events was developed to make all fire events a set of mutually exclusive events, which can facilitate arithmetic summation in fire risk quantification. A simple example is given to confirm the applicability of the present method for a 2x3 rectangular fire area. Also, a feasible asymptotic approach is discussed to reduce the computational burden for fire risk quantification

  9. Influence of Fire Mosaics, Habitat Characteristics and Cattle Disturbance on Mammals in Fire-Prone Savanna Landscapes of the Northern Kimberley.

    Science.gov (United States)

    Radford, Ian J; Gibson, Lesley A; Corey, Ben; Carnes, Karin; Fairman, Richard

    2015-01-01

    Patch mosaic burning, in which fire is used to produce a mosaic of habitat patches representative of a range of fire histories ('pyrodiversity'), has been widely advocated to promote greater biodiversity. However, the details of desired fire mosaics for prescribed burning programs are often unspecified. Threatened small to medium-sized mammals (35 g to 5.5 kg) in the fire-prone tropical savannas of Australia appear to be particularly fire-sensitive. Consequently, a clear understanding of which properties of fire mosaics are most instrumental in influencing savanna mammal populations is critical. Here we use mammal capture data, remotely sensed fire information (i.e. time since last fire, fire frequency, frequency of late dry season fires, diversity of post-fire ages in 3 km radius, and spatial extent of recently burnt, intermediate and long unburnt habitat) and structural habitat attributes (including an index of cattle disturbance) to examine which characteristics of fire mosaics most influence mammals in the north-west Kimberley. We used general linear models to examine the relationship between fire mosaic and habitat attributes on total mammal abundance and richness, and the abundance of the most commonly detected species. Strong negative associations of mammal abundance and richness with frequency of late dry season fires, the spatial extent of recently burnt habitat (post-fire age fire age classes in the models. Our results indicate that both a high frequency of intense late dry season fires and extensive, recently burnt vegetation are likely to be detrimental to mammals in the north Kimberley. A managed fire mosaic that reduces large scale and intense fires, including the retention of ≥4 years unburnt patches, will clearly benefit savanna mammals. We also highlighted the importance of fire mosaics that retain sufficient shelter for mammals. Along with fire, it is clear that grazing by introduced herbivores also needs to be reduced so that habitat quality is

  10. Standard on fire protection for self-propelled and mobile surface mining equipment. 2001 ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Safeguard life and property against fire and related hazards in mines with the latest requirements in NFPA 121. This 2001 edition covers fire detection, suppression, ignition sources, fire risk assessment and maintenance of mining equipment systems. 4 apps.

  11. Appraisal of Fire Safety Management Systems at Educational Buildings

    Directory of Open Access Journals (Sweden)

    Nadzim N.

    2014-01-01

    Full Text Available Educational buildings are one type of government asset that should be protected, and they play an important role as temporary communal meeting places for children, teachers and communities. In terms of management, schools need to emphasize fire safety for their buildings. It is well known that fires are not only a threat to the building’s occupants, but also to the property and the school environment. A study on fire safety management has been carried out on schools that have recently experienced fires in Penang. From the study, it was found that the school buildings require further enhancement in terms of both active and passive fire protection systems. For instance, adequate fire extinguishers should be provided to the school and the management should inspect and maintain fire protection devices regularly. The most effective methods to increase the level of awareness on fire safety are by organizing related programs on the management of fire safety involving all staff, teachers and students, educational talks on the dangers of fire and important actions to take in the event of an emergency, and, lastly, to appoint particular staff to join the management safety team in schools.

  12. Design of Fire/Gas Penetration Seals and fire exposure tests for Tokamak Fusion Test Reactor experimental areas

    International Nuclear Information System (INIS)

    Cavalluzzo, S.

    1983-01-01

    A Fire/Gas Penetration Seal is required in every penetration through the walls and ceilings into the Test Cell housing the Tokamak Fusion Test Reactor (TFTR), as well as other adjacent areas to protect the TFTR from fire damage. The penetrations are used for field coil lead stems, diagnostics systems, utilities, cables, trays, mechanical devices, electrical conduits, vacuum liner, air conditioning ducts, water pipes, and gas pipes. The function of the Fire/Gas Penetration Seals is to prevent the passage of fire and products of combustion through penetrations for a period of time up to three hours and remain structurally intact during fire exposure. The Penetration Seal must withstand, without rupture, a fire hose water stream directed at the hot surface. There are over 3000 penetrations ranging in size from several square inches to 100 square feet, and classified into 90 different types. The material used to construct the Fire/Gas Penetration Seals consist of a single and a two-component room temperature vulcanizing (RTV) silicone rubber compound. Miscellaneous materials such as alumina silica refractory fibers in board, blanket and fiber forms are also used in the construction and assembly of the Seals. This paper describes some of the penetration seals and the test procedures used to perform the three-hour fire exposure tests to demonstrate the adequacy of the seals

  13. Benefits of Allothermal Biomass Gasification for Co-Firing

    Energy Technology Data Exchange (ETDEWEB)

    Van der Meijden, C.M.; Van der Drift, A.; Vreugdenhil, B.J. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-04-15

    Many countries have set obligations to reduce the CO2 emissions from coal fired boilers. Co-firing of biomass in existing coal fired power plants is an attractive solution to reduce CO2 emissions. Co-firing can be done by direct mixing of biomass with coal (direct co-firing) or by converting the biomass into a gas or liquid which is fired in a separate burner (indirect co-firing). Direct co-firing is a rather simple solution, but requires a high quality and expensive biomass fuel (e.g. wood pellets). Indirect co-firing requires an additional installation that converts the solid biomass into a gas or liquid, but has the advantage that it can handle a wide range of cheap biomass fuels (e.g. demolition wood) and most of the biomass ash components are separated from the gas before it enters the boiler. Separation of biomass ash can prevent fouling issues in the boiler. Indirect co-firing, using biomass gasification technology, is already common practice. In Geertruidenberg (the Netherlands) a 80 MWth Lurgi CFB gasifier produces gas from demolition wood which is co-fired in the Amer PC boiler. In Ruien (Belgium) a 50 MWth Foster Wheeler fluidized bed gasifier is in operation. The Energy research Centre of the Netherlands (ECN) developed a 'second generation' allothermal gasifier called the MILENA gasifier. This gasifier has some major advantages over conventional fluidized bed gasifiers. The heating value of the produced gas is approximately 2.5 times higher than of gas produced by conventional bubbling / circulating fluidized bed gasifiers. This results in smaller adaptations to the membrane wall of the boiler for the gas injection, thus lower costs. A major disadvantage of most fluidized bed gasifiers is the incomplete conversion of the fuel. Typical fuel conversions vary between 90 and 95%. The remaining combustible material, also containing most of the biomass ash components, is blown out of the gasifier and removed from the gas stream by a cyclone to

  14. Special Frits for Direct-On Enamelling of Pipelines

    International Nuclear Information System (INIS)

    Berdzenishvili, I.; Siradze, M.; Erokhin, V.; Kldiashvili, R.

    2010-01-01

    The compositions of low-melting zirconium-strontium frits have been developed for direct-on enamelling of pipes. Owing to the given combination of active cations, toxic fluorine and expensive nickel and lithium were eliminated from glass frit compositions. The enamels were subjected to firing by the induction method. In the synthesized enamels, the optimal complex of properties combining high corrosion-resistant and thermo-mechanic indices, adhesive strength and required specifications was realized. These enamels are recommended for testing on pipelines. (author)

  15. Fire Hazards Analysis for the 200 Area Interim Storage Area

    International Nuclear Information System (INIS)

    JOHNSON, D.M.

    2000-01-01

    This documents the Fire Hazards Analysis (FHA) for the 200 Area Interim Storage Area. The Interim Storage Cask, Rad-Vault, and NAC-1 Cask are analyzed for fire hazards and the 200 Area Interim Storage Area is assessed according to HNF-PRO-350 and the objectives of DOE Order 5480 7A. This FHA addresses the potential fire hazards associated with the Interim Storage Area (ISA) facility in accordance with the requirements of DOE Order 5480 7A. It is intended to assess the risk from fire to ensure there are no undue fire hazards to site personnel and the public and to ensure property damage potential from fire is within acceptable limits. This FHA will be in the form of a graded approach commensurate with the complexity of the structure or area and the associated fire hazards

  16. Study of the physicochemical properties of an extinguishing powder for sodium fires: aging, fabrication, and mechanism of extinction

    International Nuclear Information System (INIS)

    Kusumanindyah, Nur-Andriani-Pramudita

    2016-01-01

    The French atomic and alternatives Energy Commission (CEA) developed an effective powder capable of extinguishing sodium fire. It is a powder based on a mixture of lithium carbonate (Li_2CO_3) and low-hydrated sodium carbonate (Na_2CO_3.H_2O) in a near eutectic proportion, with a melting temperature of around 500 C, associated with graphite. However, ever since the dismantling of several old sodium installations, CEA has at its disposal an important stock of unused powder batches. The idea of re-utilizing these powders initiates the question about their efficiency to extinguish a sodium fire after long term storage. This study proposed the physicochemical analyses of these powders in order to identify their compositions and characteristics for different batches. The results highlight the presence of lithium sodium carbonate (LiNaCO_3) and trona (Na_2CO_3.NaHCO_3.2H_2O), which are not mentioned in the patent. The aging experiments were developed to study the role of moisture and ambient carbon dioxide during the storage. The results showed that LiNaCO_3 is sensitive to the presence of moisture, able to transform it into lithium carbonate and sodium carbonate monohydrate, meanwhile the latter reacts with water and carbon dioxide to form trona. a study of the formation of LiNaCO_3 allowed the understanding of the fabrication method of the powder. This compound is found to be produced as the results of mechano-chemical reactions between Li_2CO_3 and Na_2CO_3.H_2O during the grinding process. The Chris(X)ti-Na experimental facility is built to understand the mechanisms of extinction especially related to the role of physicochemical properties on extinction. Two steps of extinction mechanisms are proposed that includes (1) the formation of liquid sodium hydroxide (NaOH) and (2) the melting of eutectic carbonates. The first step can happen directly (via the direct reaction of trona and/or Na_2CO_3.H_2O with Na(g) and/or Na_2O(s)) or indirectly (via the decomposition

  17. IoT-Based Intelligent Modeling of Smart Home Environment for Fire Prevention and Safety

    OpenAIRE

    Faisal Saeed; Anand Paul; Abdul Rehman; Won Hwa Hong; Hyuncheol Seo

    2018-01-01

    Fires usually occur in homes because of carelessness and changes in environmental conditions. They cause threats to the residential community and may result in human death and property damage. Consequently, house fires must be detected early to prevent these types of threats. The immediate notification of a fire is the most critical issue in domestic fire detection systems. Fire detection systems using wireless sensor networks sometimes do not detect a fire as a consequence of sensor failure....

  18. The improvement for fire retardant and radiation resistance characteristics of chloroprene rubber

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. Y.; Lee, C.; Kim, P. J.; Kim, J. H

    2004-04-01

    In the report, in order to improve the fire retardancy better Chloroprene Rubber (CR) after adding each fixed amount of inorganic metallic hydroxide, and then compared and assessed fire retardancy with electrical properties and mechanical properties we intended to choose the most excellent additives. Also according to Co{sup 60} {gamma}-ray irradiation, we compared electrical, echanical and fire retardant characteristics to analyse to have the additives of inorganic filler effect on CR's antirad characteristic. In result, CR containing inorganic additive, advanced considerably fire retardant characteristics, but seems to be tended to declined electrical and mechanical characteristics on the whole. In syntherically comparison, the specimen viewed the most excellent characteristics is CR containing Magnesium hydroxide. As to Co{sup 60} {gamma}-ray irradiated Chloroprene rubber containing inorganic additives, fire retardant characteristic are improved, but electrical and mechanical properties are deteriorated as a function of radiation dose. Comparing before irradiation and after irradiation, the best inorganic filler into CR consider Magnesium hydroxide. In this report, in case of adding 30 phr of inorganic filler to CR we observed fire retardancy and radiation resistance characteristics change in according to the kinds of additives, but the research for choosing the optimum amount of additives is considered to progress from now on as adjusting the amount of additives presented excellent characteristics.

  19. Directional excitation of Rg due to ripple-fired explosions: 2-Dimensional finite-difference simulations

    International Nuclear Information System (INIS)

    Jih, Rong-Song

    1993-01-01

    A major issue for the Non-Proliferation Treaty is the discrimination of large chemical explosions from possible clandestine or small nuclear tests. Unless discrimination is possible, the numerous mining blasts could give ample opportunity for concealing clandestine tests. Ripple-fired explosions are commonly used to fragment rocks during quarry and open-pit mining. The periodicity inherent in the ripple firing could produce a seismic reinforcement at the frequency of the delay between shots or rows. It has been suggested that the convolution of a single explosion with a comb function of variable spacing and variable amplitude can be used to model the distinctive signature of ripple firing. Baumgardt and Ziegler (1988) delicately demonstrated that the incoherent array-stack spectra can be used to identify some multiple shots recorded at NORSAR. By superpositioning the waveform due to a single shot with proper time delay, they were able to model the source multiplicity under the assumption that the spatial spreading of the shots is negligible with respect to the distance to the receiver. The work by Stump et al. successfully characterized the major features of the wavefield due to ripple firings at near-source ranges

  20. Comparison of the characteristics of fire and non-fire households in the 2004-2005 survey of fire department-attended and unattended fires.

    Science.gov (United States)

    Greene, Michael A

    2012-06-01

    Comparison of characteristics of fire with non-fire households to determine factors differentially associated with fire households (fire risk factors). National household telephone survey in 2004-2005 by the US Consumer Product Safety Commission with 916 fire households and a comparison sample of 2161 non-fire households. There were an estimated 7.4 million fires (96.6% not reported to fire departments) with 130,000 injuries. Bivariate analysis and multivariate logistic regression analyses to assess differences in household characteristics. Significant factors associated with fire households were renting vs. owning (OR 1.988 pfire households with non-cooking fires (OR 1.383 p=0.0011). Single family houses were associated with non-fire households in the bivariate analysis but not in the multivariate analyses. Renting, household members under 18 years old and smokers are risk factors for unattended fires, similar to the literature for fatal and injury fires. Differences included household members over 65 years old (associated with non-fire households), college/postgraduate education (associated with fire households) and lack of significance of income. Preventing cooking fires (64% of survey incidents), smoking prevention efforts and fire prevention education for families with young children have the potential for reducing unattended fires and injuries.

  1. Monitoring Fires from Space and Getting Data in to the hands of Users: An Example from NASA's Fire Information for Resource Management System (FIRMS)

    Science.gov (United States)

    Davies, D.; Wong, M.; Ilavajhala, S.; Molinario, G.; Justice, C. O.

    2012-12-01

    This paper discusses the broad uptake of MODIS near-real-time (NRT) active fire data for applications. Prior to the launch of MODIS most real-time satellite-derived fire information was obtained from NOAA AVHRR via direct broadcast (DB) systems. Whilst there were efforts to make direct broadcast stations affordable in developing countries, such as through the Local Applications of Satellite Remote Technologies (LARST), these systems were relatively few and far between and required expertise to manage and operate. One such system was in Etosha National Park (ENP) in Namibia. Prior to the installation of the AVHRR DB system in ENP, fires were reported by rangers and the quality, accuracy and timing of reports was variable. With the introduction of the DB station, early warning of fires improved and fire maps could be produced for park managers within 2-3 hours by staff trained to process data, interpret images and produce maps. Up keep and maintenance of such systems was relatively costly for parks with limited resources therefore when global fire data from MODIS became available uptake was widespread. NRT data from MODIS became availalbe through a collaboration between the MODIS Fire Team and the US Forest Service (USFS) Remote Sensing Applications Center to provide rapid access to imagery to help fight the Montana wildfires of 2001. This prompted the development of a Rapid Response System for fire data that eventually led to the operational use of MODIS data by the USFS for fire monitoring. Building on this success, the Fire Information for Resource Management System (FIRMS) project was funded by NASA Applications, and developed under the umbrella of the GOFC-GOLD Fire program, to further improve products and services for the global fire information community. FIRMS was developed as a web-based geospatial tool, offering a range of geospatial data services, including a fire email alert service which is widely used around the world. FIRMS was initially developed to

  2. Remote sensing of fire severity: linking post-fire reflectance data with physiological responses in two western conifer species

    Science.gov (United States)

    Sparks, A. M.; Smith, A. M.; Kolden, C.; Apostol, K. G.; Boschetti, L.

    2014-12-01

    Fire is a common disturbance in forested ecosystems in the western U.S. and can be responsible for long-term impacts on vegetation and soil. An improved understanding of how ecosystems recover after fire is necessary so that land managers can plan for and mitigate the effects of these disturbances. Although several studies have attempted to link fire intensity with severity, direct links between spectral indices of severity and key physiological changes in vegetation are not well understood. We conducted an assessment of how two western conifer species respond to four fire radiative energy treatments, with spectra acquired pre- and up to a month post-burn. After transforming the spectral data into Landsat 8 equivalent reflectance, burn severity indices commonly used in the remote sensing community were compared to concurrent physiological measurements including gas exchange and photosynthetic rate. Preliminary results indicate significant relationships between several fire severity indices and physiological responses measured in the conifer seedlings.

  3. BBN Model with Quantitative Inputs for Risk Analysis of Uncontrolled Fire in Machinery Space

    OpenAIRE

    Azizpour, Hooshyar

    2016-01-01

    The past decades has witnessed a significant increase in the number and volume of international trade through the sea. Thousands of ships are sailing in the coastal and international waters all over the world. Accident in the sea transport not only results loss of property for the owners of vessels and traders of cargo, but also threatens the environment and the humans who are directly or indirectly associated with the marine industry. One of the most dangerous accidents in ships is fire and...

  4. Mid-21st-century climate changes increase predicted fire occurrence and fire season length, Northern Rocky Mountains, United States

    Science.gov (United States)

    Riley, Karin L.; Loehman, Rachel A.

    2016-01-01

    Climate changes are expected to increase fire frequency, fire season length, and cumulative area burned in the western United States. We focus on the potential impact of mid-21st-century climate changes on annual burn probability, fire season length, and large fire characteristics including number and size for a study area in the Northern Rocky Mountains. Although large fires are rare they account for most of the area burned in western North America, burn under extreme weather conditions, and exhibit behaviors that preclude methods of direct control. Allocation of resources, development of management plans, and assessment of fire effects on ecosystems all require an understanding of when and where fires are likely to burn, particularly under altered climate regimes that may increase large fire occurrence. We used the large fire simulation model FSim to model ignition, growth, and containment of wildfires under two climate scenarios: contemporary (based on instrumental weather) and mid-century (based on an ensemble average of global climate models driven by the A1B SRES emissions scenario). Modeled changes in fire patterns include increased annual burn probability, particularly in areas of the study region with relatively short contemporary fire return intervals; increased individual fire size and annual area burned; and fewer years without large fires. High fire danger days, represented by threshold values of Energy Release Component (ERC), are projected to increase in number, especially in spring and fall, lengthening the climatic fire season. For fire managers, ERC is an indicator of fire intensity potential and fire economics, with higher ERC thresholds often associated with larger, more expensive fires. Longer periods of elevated ERC may significantly increase the cost and complexity of fire management activities, requiring new strategies to maintain desired ecological conditions and limit fire risk. Increased fire activity (within the historical range of

  5. Sodium Fire Demonstration Facility Design and Operation

    International Nuclear Information System (INIS)

    Cho, Youngil; Kim, Jong-Man; Lee, Jewhan; Hong, Jonggan; Yeom, Sujin; Cho, Chungho; Jung, Min-Hwan; Gam, Da-Young; Jeong, Ji-Young

    2014-01-01

    Although sodium has good characteristics such as high heat transfer rate and stable nuclear property, it is difficult to manage because of high reactivity. Sodium is solid at the room temperature and it easily reacts with oxygen resulting in fire due to the reaction heat. Thus, sodium must be stored in a chemically stable place, i.e., an inert gas-sealed or oil filled vessel. When a sodium fire occurs, the Na 2 O of white fume is formed. It is mainly composed of Na 2 O 2 , NaOH, and Na 2 CO 3 , ranging from 0.1 to several tens of micrometers in size. It is known that the particle size increases by aggregation during floating in air. Thus, the protection method is important and should be considered in the design and operation of a sodium system. In this paper, sodium fire characteristics are described, and the demonstration utility of outbreak of sodium fire and its extinguishing is introduced. In this paper, sodium fire characteristics and a demonstration facility are described. The introduced sodium fire demonstration facility is the only training device used to observe a sodium fire and extinguish it domestically. Furthermore, the type of sodium fire will be diversified with the enhancement of the utility. It is expected that this utility will contribute to experience in the safe treatment of sodium by the handlers

  6. GASIFICATION BASED BIOMASS CO-FIRING - PHASE I; SEMIANNUAL

    International Nuclear Information System (INIS)

    Babul Patel; Kevin McQuigg; Robert F. Toerne

    2001-01-01

    Biomass gasification offers a practical way to use this locally available fuel source for co-firing traditional large utility boilers. The gasification process converts biomass into a low Btu producer gas that can be fed directly into the boiler. This strategy of co-firing is compatible with variety of conventional boilers including natural gas fired boilers as well as pulverized coal fired and cyclone boilers. Gasification has the potential to address all problems associated with the other types of co-firing with minimum modifications to the existing boiler systems. Gasification can also utilize biomass sources that have been previously unsuitable due to size or processing requirements, facilitating a reduction in the primary fossil fuel consumption in the boiler and thereby reducing the greenhouse gas emissions to the atmosphere

  7. Exploiting heat treatment effects on SMAs macro and microscopic properties in developing fire protection devices

    Science.gov (United States)

    Burlacu, L.; Cimpoeşu, N.; Bujoreanu, L. G.; Lohan, N. M.

    2017-08-01

    Ni-Ti shape memory alloys (SMAs) are intelligent alloys which demonstrate unique properties, such as shape memory effect, two-way shape memory effect, super-elasticity and vibration damping which, accompanied by good processability, excellent corrosion resistance and biocompatibility as well as fair wear resistance and cyclic stability, enabled the development of important industrial applications (such as sensors, actuators, fasteners, couplings and valves), medical applications (such as stents, bone implants, orthodontic archwires, minimal invasive surgical equipment) as well as environmental health and safety devices (anti-seismic dampers, fire safety devices). The phase transitions in Ni-Ti SMAs are strongly influenced by processing methods, chemical compositions and thermomechanical history. This paper presents a study of the effects of heat treatment on the mechanical and thermal properties of commercial Ni-Ti shape memory alloy (SMA). The experimental work involved subjecting a SMA rod to heat-treatment consisting in heating up to 500°C, 10 minutes-maintaining and water quenching. Mechanical properties were highlighted by microhardness tests while thermal characteristics were emphasized by differential scanning calorimetry (DSC). The presence of chemical composition fluctuations was checked by X-ray energy dispersive spectroscopy performed with an EDAX Bruker analyzer.

  8. Managing the risks of risk management on large fires

    Science.gov (United States)

    Donald G. MacGregor; Armando González-Cabán

    2013-01-01

    Large fires pose risks to a number of important values, including the ecology, property and the lives of incident responders. A relatively unstudied aspect of fire management is the risks to which incident managers are exposed due to organizational and sociopolitical factors that put them in a position of, for example, potential liability or degradation of their image...

  9. Overview of the Fire Lab at Missoula Experiments (FLAME)

    Science.gov (United States)

    S. M. Kreidenweis; J. L. Collett; H. Moosmuller; W. P. Arnott; WeiMin Hao; W. C. Malm

    2010-01-01

    The Fire Lab at Missoula Experiments (FLAME) used a series of open biomass burns, conducted in 2006 and 2007 at the Forest Service Fire Science Laboratory in Missoula, MT, to characterize the physical, chemical and optical properties of biomass combustion emissions. Fuels were selected primarily based on their projected importance for emissions from prescribed and wild...

  10. Investigation of Fire Safety Awareness and Management in Mall

    Directory of Open Access Journals (Sweden)

    Abdul Rahim N.

    2014-03-01

    Full Text Available In spite of having sufficient fire safety system installed in buildings, the incidence of fire hazard becomes the furthermost and supreme threat to health and safety, as well as property to any community. In order to make sure that the safety of the building and its users, the fundamental features depends on the fire precaution system and equipment which should be according to the standard requirements. Nevertheless, the awareness on fire safety could necessarily alleviate the damages or rate of fatality during the event of fire. This paper presents the results on the investigation of fire safety awareness and management, concentrating on shopping mall. The endeavour of this study is to explore the level of fire safety knowledge of the users in the mall, and to study the effectiveness level of fire safety management in a mall. From the study, public awareness is highly related to understanding human behaviour and their personal background. The respondents’ levels of awareness are rather low, which reflects on their poor action when facing emergency situation during fire. The most effective methods identified to improve the awareness and effectiveness of fire safety level is through involvement in related fire safety programmes, distribution of pamphlets or brochures on fire safety and appointing specific personnel for Emergency Response Team in the mall.

  11. Targeting Forest Management through Fire and Erosion Modeling

    Science.gov (United States)

    Elliot, William J.; Miller, Mary Ellen; MacDonald, Lee H.

    2013-04-01

    Forests deliver a number of ecosystem services, including clean water. When forests are disturbed by wildfire, the timing and quantity of runoff can be altered, and the quality can be severely degraded. A modeling study for about 1500 km2 in the Upper Mokelumne River Watershed in California was conducted to determine the risk of wildfire and the associated potential sediment delivery should a wildfire occur, and to calculate the potential reduction in sediment delivery that might result from fuel reduction treatments. The first step was to predict wildfire severity and probability of occurrence under current vegetation conditions with FlamMap fire prediction tool. FlamMap uses current vegetation, topography, and wind characteristics to predict the speed, flame length, and direction of a simulated flame front for each 30-m pixel. As the first step in the erosion modeling, a geospatial interface for the WEPP model (GeoWEPP) was used to delineate approximately 6-ha hillslope polygons for the study area. The flame length values from FlamMap were then aggregated for each hillslope polygon to yield a predicted fire intensity. Fire intensity and pre-fire vegetation conditions were used to estimate fire severity (either unburned, low, moderate or high). The fire severity was combined with soil properties from the STATSGO database to build the vegetation and soil files needed to run WEPP for each polygon. Eight different stochastic climates were generated to account for the weather variability within the basin. A modified batching version of GeoWEPP was used to predict the first-year post-fire sediment yield from each hillslope and subwatershed. Estimated sediment yields ranged from 0 to more than 100 Mg/ha, and were typical of observed values. The polygons that generated the greatest amount of sediment or that were critical for reducing fire spread were identified, and these were "treated" by reducing the amount of fuel available for a wildfire. The erosion associated with

  12. Post-fire mulching and soil hydrological response

    Science.gov (United States)

    Jordán, Antonio; Zavala, Lorena M.; Gordillo-Rivero, Ángel J.; Muñoz-Rojas, Miriam; Keesstra, Saskia; Cerdà, Artemi

    2017-04-01

    In general, one of the major threats after a forest fire is the increased erosion. This can occur due to the erosive impact of rainfall after a drastic reduction of vegetation cover or to changes in soil surface properties that contribute to enhanced runoff flow. There is a consensus among researchers that one of the best ways to reduce this risk is to apply a mulch cover (straw, shredded wood or other materials) immediately after fire. In this study, we studied the effectiveness of various types of mulch materials for the reduction of runoff and soil loss during the first 3 years after a forest fire, in plots of different sizes, with special attention to water repellency and physical properties of the soil surface. In general, straw mulch reduced both runoff and erosion rate more than other treatments. However, the effect was much more important on larger plots. This may be due to specific processes and impacts on sediment connectivity and surface water flow. Therefore, the effect of the scale seems to be an important factor in the management of burnt soils.

  13. Direct compression properties of microcrystalline cellulose and its ...

    African Journals Online (AJOL)

    The influence of silicified microcrystalline cellulose (SMCC) on the flow, compaction and tableting properties of metronidazole powder was investigated. The study compared medium grades of both SMCC and standard microcrystalline cellulose (MCC) as direct compressible excipients. The bulk densities, Hausner quotient ...

  14. Firing: the proof test for ceramic processing

    International Nuclear Information System (INIS)

    Kingery, W.D.

    1975-01-01

    The object of ceramic processing is to form ware having certain shapes and properties. Thus, one test of the success of processing procedures must be in terms of the resulting structure and characteristics of a material after firing. During the firing process some few variations resulting from processing may be evened out, but the great majority of variation tends to be amplified. Examination of a few cases illustrates the nature of the defect amplification process. (U.S.)

  15. Short- and medium-term effects of three fire fighting chemicals on the properties of a burnt soil

    International Nuclear Information System (INIS)

    Couto-Vazquez, A.; Gonzalez-Prieto, S.J.

    2006-01-01

    The impact of three fire fighting chemicals (FFC) on 11 chemical soil properties and on soil recovery (0-2 cm depth) was evaluated 1, 30, 90 and 365 days after a prescribed fire. Five treatments were considered: unburnt soil (United States) and burnt soil with 2 l m -2 of water alone (BS) or mixed with the foaming agent Auxquimica RFC-88 at 1% (BS + Fo), Firesorb at 1.5% (BS + Fi) and FR Cross ammonium polyphosphate at 20% (BS + Ap). At t = 1 day, soil pH increases in the order US 15 N decreased in all burnt soils (significatively in BS + Ap) due to the inputs of 15 N depleted ashes from leguminous vegetation. Compared with US, soil δ 15 N increased significantly in all burnt plots between t = 90 days (30 days in BS + Ap) and t = 365 days, suggesting a medium-term fire-triggered increment of N outputs ( 15 N depleted). As is habitually the case, there was a transient post-fire increase of NH 4 + -N levels (significative for BS + FFC plots) that lasted for 30 (BS, BS + Fo and BS + Fi) to 90 days (BS + Ap). The high initial NH 4 + -N levels in BS + Ap (200x that of US; 9-18x those of BS, BS + Fo and BS + Fi), and its persistence can delay the post-fire vegetation recovery due to the toxicity of NH 4 + to seeds and seedlings. NO 3 -N levels changed significantly only in BS + Ap between t = 30 and t = 90 days due to the nitrification of its large NH 4 + -N pool. Except in BS + Ap, whose soil P levels were 70-140x (t = 1 days) and 10-20x (t = 365 days) higher than in the other treatments, available P content in BS and BS + FFC was not significatively higher than in US. The concentrations of available cations in BS and BS + FFC were higher (not always significatively, except for K) than in US until t = 90 days, likely due to ashes- and FFC-derived cations. Contrarily to divalent cations, monovalent cations (more soluble and easily leached) decreased slowly until t = 90 days

  16. Calculation of Fire Severity Factors and Fire Non-Suppression Probabilities For A DOE Facility Fire PRA

    International Nuclear Information System (INIS)

    Elicson, Tom; Harwood, Bentley; Lucek, Heather; Bouchard, Jim

    2011-01-01

    Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. The fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: Development of time-dependent fire heat release rate profiles (required as input to CFAST), Calculation of fire severity factors based on CFAST detailed fire modeling, and Calculation of fire non-suppression probabilities.

  17. Fire risk analysis, fire simulation, fire spreading and impact of smoke and heat on instrumentation electronics - State-of-the-Art Report

    International Nuclear Information System (INIS)

    Roewekamp, M.; Bertrand, R.; Bonneval, F.; Hamblen, D.; Siu, N.; Aulamo, H.; Martila, J.; Sandberg, J.; Virolainen, R.

    2000-01-01

    OECD countries. The contents of each chapter are based on the writers' knowledge on his or her national practices and on the results of the questionnaire. The emphasis in the descriptions of the national practices also reflects the information supplied by the responding countries. Fire PSA is also used in other OECD countries, but the scope of this report is limited to those countries which responded to the questionnaire. The contents of this report are as follows: Fire PSA methodology overview - Based on a review of fire risk studies performed in the contributing countries, the report addresses different methodology and applications issues. Methodology issues, treated in Chapter 2, include the treatment of physical barriers, fire detection and suppression systems and fire fighting. They also include the treatment of operator actions and dependencies (both direct and indirect) between a fire and the plant's safety systems, definition of initiating events, and screening methods. Key assumptions and the effect of plant operational state (i.e., full power vs. low power operation) are dealt with in the report as well. Fire simulation models and codes applied or available - Chapter 3 of the report identifies which fire simulation codes have been used in actual PSAs. The models and scenarios used in different codes are described. To build confidence on fire simulation models, validation against experimental results in different types of fires is necessary. Fire experiments and the pre- and post experiment calculation used for code validation as well as ongoing fire simulation code development projects are discussed. Examples of fire scenarios and typical modeling assumptions are treated and numerous references are given in Chapter 3. References for experimental case studies and related simulation models and codes used for analyzing the production and spreading of smoke are also provided. The impact of smoke and heat - The immediate consequences of fires are caused by heat

  18. [Lightning-caused fire, its affecting factors and prediction: a review].

    Science.gov (United States)

    Zhang, Ji-Li; Bi, Wu; Wang, Xiao-Hong; Wang, Zi-Bo; Li, Di-Fei

    2013-09-01

    Lightning-caused fire is the most important natural fire source. Its induced forest fire brings enormous losses to human beings and ecological environment. Many countries have paid great attention to the prediction of lightning-caused fire. From the viewpoint of the main factors affecting the formation of lightning-caused fire, this paper emphatically analyzed the effects and action mechanisms of cloud-to-ground lightning, fuel, meteorology, and terrain on the formation and development process of lightning-caused fire, and, on the basis of this, summarized and reviewed the logistic model, K-function, and other mathematical methods widely used in prediction research of lightning-caused fire. The prediction methods and processes of lightning-caused fire in America and Canada were also introduced. The insufficiencies and their possible solutions for the present researches as well as the directions of further studies were proposed, aimed to provide necessary theoretical basis and literature reference for the prediction of lightning-caused fire in China.

  19. Cutting costs through detailed probabilistic fire risk analysis

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luiz; Huser, Asmund; Vianna, Savio [Det Norske Veritas PRINCIPIA, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    A new procedure for calculation of fire risks to offshore installations has been developed. The purposes of the procedure are to calculate the escalation and impairment frequencies to be applied in quantitative risk analyses, to optimize Passive Fire Protection (PFP) arrangement, and to optimize other fire mitigation means. The novelties of the procedure are that it uses state of the art Computational Fluid Dynamics (CFD) models to simulate fires and radiation, as well as the use of a probabilistic approach to decide the dimensioning fire loads. A CFD model of an actual platform was used to investigate the dynamic properties of a large set of jet fires, resulting in detailed knowledge of the important parameters that decide the severity of offshore fires. These results are applied to design the procedure. Potential increase in safety is further obtained for those conditions where simplified tools may have failed to predict abnormal heat loads due to geometrical effects. Using a field example it is indicated that the probabilistic approach can give significant reductions in PFP coverage with corresponding cost savings, still keeping the risk at acceptable level. (author)

  20. Radiatively-driven processes in forest fire and desert dust plumes

    Energy Technology Data Exchange (ETDEWEB)

    Weinzierl, Bernadett Barbara

    2008-07-01

    The absorption of solar radiation by atmospheric aerosol particles is important for the climate effects of aerosols. Absorption by aerosol particles heats atmospheric layers, even though the net effect for the entire atmospheric column may still be a cooling. Most experimental studies on absorbing aerosols so far focussed mainly on the aerosol properties and did not consider the influence of the aerosols on the thermodynamic structure of the atmosphere. In this study, data from two international aircraft field experiments, the Intercontinental Transport of Ozone and Precursors study (ITOP) 2004 and the Saharan Mineral Dust Experiment (SAMUM) 2006 are investigated. The ITOP data were collected before the work on this thesis started, while the logistics and the instrument preparation of the SAMUM campaign, the weather forecast during SAMUM and the in-situ aerosol measurements during SAMUM were done within this thesis. The experimental data are used to explore the impact of layers containing absorbing forest fire and desert dust aerosol particles on the atmospheric stability and the implications of a changed stability on the development of the aerosol microphysical and optical properties during long-range transport. For the first time, vertical profiles of the Richardson number Ri are used to assess the stability and mixing in forest fire and desert dust plumes. Also for the first time, the conclusions drawn from the observations of forest fire and desert dust aerosol, at first glance apparently quite different aerosol types, are discussed from a common perspective. Two mechanisms, the selfstabilising and the sealed ageing effect, acting in both forest fire and desert dust aerosol layers, are proposed to explain the characteristic temperature structure as well as the aerosol properties observed in lofted forest fire and desert dust plumes. The proposed effects impact on the ageing of particles within the plumes and reduce the plume dilution, therefore extending the

  1. A review of fire interactions and mass fires

    Science.gov (United States)

    Mark A. Finney; Sara S. McAllister

    2011-01-01

    The character of a wildland fire can change dramatically in the presence of another nearby fire. Understanding and predicting the changes in behavior due to fire-fire interactions cannot only be life-saving to those on the ground, but also be used to better control a prescribed fire to meet objectives. In discontinuous fuel types, such interactions may elicit fire...

  2. Fire history, effects, and management in southern Nevada [Chapter 5] (Executive Summary)

    Science.gov (United States)

    Matthew L. Brooks; Jeanne C. Chambers; Randy A. McKinley

    2013-01-01

    Fire can be both an ecosystem stressor and a critical ecosystem process, depending on when, where, and under what conditions it occurs on the southern Nevada landscape. Fire can also pose hazards to human life and property, particularly in the wildland/ urban interface (WUI). The challenge faced by land managers is to prevent fires from occurring where they are likely...

  3. Fire characteristics charts for fire behavior and U.S. fire danger rating

    Science.gov (United States)

    Faith Ann Heinsch; Pat Andrews

    2010-01-01

    The fire characteristics chart is a graphical method of presenting U.S. National Fire Danger Rating indices or primary surface or crown fire behavior characteristics. A desktop computer application has been developed to produce fire characteristics charts in a format suitable for inclusion in reports and presentations. Many options include change of scales, colors,...

  4. Properties of conductive thick-film inks

    Science.gov (United States)

    Holtze, R. F.

    1972-01-01

    Ten different conductive inks used in the fabrication of thick-film circuits were evaluated for their physical and handling properties. Viscosity, solid contents, and spectrographic analysis of the unfired inks were determined. Inks were screened on ceramic substrates and fired for varying times at specified temperatures. Selected substrates were given additional firings to simulate the heat exposure received if thick-film resistors were to be added to the same substrate. Data are presented covering the (1) printing characteristics, (2) solderability using Sn-63 and also a 4 percent silver solder, (3) leach resistance, (4) solder adhesion, and (5) wire bonding properties. Results obtained using different firing schedules were compared. A comparison was made between the various inks showing general results obtained for each ink. The changes in firing time or the application of a simulated resistor firing had little effect on the properties of most inks.

  5. Fire protection and fire fighting in nuclear installations

    International Nuclear Information System (INIS)

    1989-01-01

    Fires are a threat to all technical installations. While fire protection has long been a well established conventional discipline, its application to nuclear facilities requires special considerations. Nevertheless, for a long time fire engineering has been somewhat neglected in the design and operation of nuclear installations. In the nuclear industry, the Browns Ferry fire in 1975 brought about an essential change in the attention paid to fire problems. Designers and plant operators, as well as insurance companies and regulators, increased their efforts to develop concepts and methods for reducing fire risks, not only to protect the capital investment in nuclear plants but also to consider the potential secondary effects which could lead to nuclear accidents. Although the number of fires in nuclear installations is still relatively large, their overall importance to the safety of nuclear power plants was not considered to be very high. Only more recently have probabilistic analyses changed this picture. The results may well have to be taken into account more carefully. Various aspects of fire fighting and fire protection were discussed during the Symposium, the first of its kind to be organized by the IAEA. It was convened in co-operation with several organizations working in the nuclear or fire protection fields. The intention was to gather experts from nuclear engineering areas and the conventional fire protection field at one meeting with a view to enhancing the exchange of information and experience and to presenting current knowledge on the various disciplines involved. The presentations at the meeting were subdivided into eight sessions: standards and licensing (6 papers); national fire safety practices (7 papers); fire safety by design (11 papers); fire fighting (2 papers); computer fire modeling (7 papers); fire safety in fuel center facilities (7 papers); fire testing of materials (3 papers); fire risk assessment (5 papers). A separate abstract was

  6. Informing the network: Improving communication with interface communities during wildland fire

    Science.gov (United States)

    Taylor, J.G.; Gillette, S.C.; Hodgson, R.W.; Downing, J.L.; Burns, M.R.; Chavez, D.J.; Hogan, J.T.

    2007-01-01

    An interagency research team studied fire communications that took place during different stages of two wildfires in southern California: one small fire of short duration and one large fire of long duration. This "quick- response" research showed that pre-fire communication planning was particularly effective for smaller fire events and parts of that planning proved invaluable for the large fire event as well. Information seeking by the affected public relied on locally convenient sources during the small fire. During the large fire, widespread evacuations disrupted many of the local informal communication networks. Residents' needs were for "real-time, " place-specific information: precise location, severity, size, and direction of spread of the fires. Fire management agencies must contribute real-time, place-specific fire information when it is most needed by the affected public, as they try to make sense out of the chaos of a wildland fire. Disseminating fire information as broadly as possible through multiple pathways will maximize the probability of the public finding the information they need. ?? Society for Human Ecology.

  7. Fire resistant polyamide based on 1-(diorganooxyphosphonyl)methyl-2,4- and -2,6diamino benzene

    Science.gov (United States)

    Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)

    1986-01-01

    1-(Diorganooxyphosphonyl)methyl2,4- and-2,6diamino benzenes are reacted with polyacylhalides and optionally comonomers to produce polyamides which have desirable heat and fire resistance properties. These polymers are used to form fibers and fabrics where fire resistance properties are important, e.g., aircraft equipment and structures.

  8. Sensitivity Analysis on Fire Modeling of Main Control Board Fire Using Fire Dynamics Simulator

    International Nuclear Information System (INIS)

    Kang, Dae Il; Lim, Ho Gon

    2015-01-01

    In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number for fire initiation places. Hanul Unit 3 NPP was selected as a reference plant for this study. In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number of fire initiation places. A main control board (MCB) fire can cause a forced main control room (MCR) abandonment of the operators as well as the function failures or spurious operations of the control and instrumentation-related components. If the MCR cannot be habitable, a safe shutdown from outside the MCR can be achieved and maintained at an alternate shutdown panel independent from the MCR. When the fire modeling for an electrical cabinet such as an MCB was performed, its many input parameters can affect the fire simulation results. This study results showed that the decrease in the height of fire ignition place and the use of single fire ignition place in fire modeling for the propagating fire shortened MCR abandonment time

  9. Sensitivity Analysis on Fire Modeling of Main Control Board Fire Using Fire Dynamics Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Lim, Ho Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number for fire initiation places. Hanul Unit 3 NPP was selected as a reference plant for this study. In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number of fire initiation places. A main control board (MCB) fire can cause a forced main control room (MCR) abandonment of the operators as well as the function failures or spurious operations of the control and instrumentation-related components. If the MCR cannot be habitable, a safe shutdown from outside the MCR can be achieved and maintained at an alternate shutdown panel independent from the MCR. When the fire modeling for an electrical cabinet such as an MCB was performed, its many input parameters can affect the fire simulation results. This study results showed that the decrease in the height of fire ignition place and the use of single fire ignition place in fire modeling for the propagating fire shortened MCR abandonment time.

  10. Fire resistant nuclear fuel cask

    International Nuclear Information System (INIS)

    Heckman, R.C.; Moss, M.

    1979-01-01

    The disclosure is directed to a fire resistant nuclear fuel cask employing reversibly thermally expansible bands between adjacent cooling fins such that normal outward flow of heat is not interfered with, but abnormal inward flow of heat is impeded or blocked

  11. Permafrost thaw and fire history: implications of boreal tree cover changes on land surface properties and turbulent energy fluxes in the Taiga Plains, Canada

    Science.gov (United States)

    Sonnentag, Oliver; Helbig, Manuel; Payette, Fanny; Wischnewski, Karoline; Kljun, Natascha; Chasmer, Laura; Pappas, Christoforos; Detto, Matteo; Baltzer, Jennifer; Quinton, William; Marsh, Philip

    2016-04-01

    . The spatial heterogeneities within the eddy covariance flux footprints (forest/wetland vs. wetland) were resolved with a two-dimensional footprint model parameterized with various remote sensing data sets. Our results suggest that an increasing coverage of wetlands at the expense of forests reduces ga and thus the efficiency of the land surface to transfer heat to the atmosphere. At the same time gs is increased and thus more moisture is lost to the atmosphere from saturated wetland surfaces. The alteration of bulk transfer land surface properties lead to drastic decreases in Bowen ratios by reducing H and increasing LE with increasing coverage of wetlands. The most pronounced contrasts between forests and wetlands are observed in H during the late snow cover period in April. We used a similar set of eddy covariance flux measurements made concurrently at Havikpak Creek (68°19' N; 133°31' W) and Trail Valley Creek (68°44' N; 133°26' W), a boreal forest and a nearby tundra site in the boreal-tundra ecotone, respectively, as a first-order proxy for potentially increasing PTC under more stable permafrost conditions in contrast to Scotty Creek. Preliminary results indicate trends in ga, gs, H and LE opposite to those observed at Scotty Creek between forests and wetlands. Our study demonstrates diverging implications of boreal tree cover changes on land surface properties and turbulent energy fluxes, thus on regional climate system feedback directions and strengths, as a function of permafrost conditions and fire history.

  12. Effects of Burn Severity and Environmental Conditions on Post-Fire Regeneration in Siberian Larch Forest

    OpenAIRE

    Thuan Chu; Xulin Guo; Kazuo Takeda

    2017-01-01

    Post-fire forest regeneration is strongly influenced by abiotic and biotic heterogeneity in the pre- and post-fire environments, including fire regimes, species characteristics, landforms, hydrology, regional climate, and soil properties. Assessing these drivers is key to understanding the long-term effects of fire disturbances on forest succession. We evaluated multiple factors influencing patterns of variability in a post-fire boreal Larch (Larix sibirica) forest in Siberia. A time-series o...

  13. Study of the effect on biodiversity of prescribed fire in the wildland-urban interface of Granada (Spain

    Directory of Open Access Journals (Sweden)

    S. Montoya

    2013-05-01

    Full Text Available The problematic of fire is evident, since in recent years the number of hectares affected in our country is very high. The aim of this study is to obtain information about soil’s behaviour under controlled burning wildland-urban interface areas, in order to prevent major forest fires without being affected soil properties. Organic carbon content and soil moisture were selected to evaluate fire effect on soil. After the analysis we can say that preventive burning in an initial stage does not affect the organic matter content or soil water retention capacity. This indicates the important role of fire intensity and duration on fire effect on soil properties.

  14. Reduction of Fire Hazard in Materials for Irrigators and Water Collectors in Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, N. V.; Konstantinova, N. I., E-mail: konstantinova-n@inbox.ru [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation); Gordon, E. P. [Research and Production Center “Kaustik” (Russian Federation); Poedintsev, E. A. [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation)

    2016-09-15

    A way of reducing the fire hazard of PVC film used to make cooling-tower irrigators and water collectors is examined. A new generation of fire retardant, nanostructured magnesium hydroxide, is used to impart fire retardant properties. The fabrication technology is optimized with a roller-calendering manufacturing technique, and the permissible ranges of fire hazard indicators for materials in irrigators and water collectors are determined.

  15. Mine-fire diagnostics applied to the Carbondale, Pennsylvania mine-fire site. Rept. of Investigations/1992

    International Nuclear Information System (INIS)

    Kim, A.G.; Justin, T.R.; Miller, J.F.

    1992-01-01

    The U.S. Bureau of Mines applied its mine fire diagnostic method to an abandoned anthracite mine fire site in Carbondale, Lackawanna County, PA. The technique to locate fires in abandoned coal mines and coal refuse piles includes the determination of hydrocarbon concentrations in mine gases, the imposition of an underground gas flow direction, and use of a surface mapping method, to define heated and cold zones in underground coal strata. The heated zones at Carbondale were characterized by elevated methane concentrations. The results of 25 communication tests were analyzed to define 2 large (approximately 100 by 250 ft) and 5 small, isolated heated zones. An approximate correlation existed between the location of the heated zones and areas of anomalous snow melt. The correlation between the results of the diagnostic test and subsurface temperatures was not significant

  16. Control Properties of Bottom Fired Marine Boilers

    DEFF Research Database (Denmark)

    Solberg, Brian; Andersen, Palle; Karstensen, Claus M. S.

    2005-01-01

    This paper focuses on model analysis of a dynamic model of a bottom fired one-pass smoke tube boiler. Linearised versions of the model are analysed to determine how gain, time constants and right half plane zeros (caused by the shrink-and-swell phenomenon) depend on the steam flow load. Furthermore...... the interactions in the system are inspected to analyse potential benefit from using a multivariable control strategy in favour of the current strategy based on single loop theory. An analysis of the nonlinear model is carried out to further determine the nonlinear characteristics of the boiler system...

  17. Flame spread and smoke temperature of full-scale fire test of car fire

    Directory of Open Access Journals (Sweden)

    Dayan Li

    2017-09-01

    Full Text Available Full-scale experiments using two 4-door sedan passenger cars, placed side by side in the reverse direction, were carried out to establish the burning behavior and describe the spread of fire to adjacent car. The temperature was measured by thermocouples. Radiant heat flux was measured with heat flux gauge placed at a distance of 5 m, at the right side of the car. Four cameras were placed inside the car and in the fire test room recording burning behavior during the test. Engine compartment was ignited by a sponge dipped with little gasoline. During the experiment, the ignition was initiated in the engine compartment of car I and approximately 20 min were enough time for fire to spread into the second car. Fully-developed burning of two cars occurred at 29 min. It was observed that the flame spread through car roof faster than through the bottom of car compartment. The fire followed a slow rate spread from engine compartment to car cab. The temperature inside the car peaked at the point of 900 °C. The peak smoke temperatures at every location were measured at the range of 89–285 °C. The smoke production at the time of 11 min to 15 min 50 s of fire was 1.76 m3/s, which was obtained through indirect calculation method.

  18. Can butterflies evade fire? Pupa location and heat tolerance in fire prone habitats of Florida.

    Science.gov (United States)

    Thom, Matthew D; Daniels, Jaret C; Kobziar, Leda N; Colburn, Jonathan R

    2015-01-01

    Butterflies such as the atala hairstreak, Eumaeus atala Poey, and the frosted elfin, Callophrys irus Godart, are restricted to frequently disturbed habitats where their larval host plants occur. Pupae of these butterflies are noted to reside at the base of host plants or in the leaf litter and soil, which may allow them to escape direct mortality by fire, a prominent disturbance in many areas they inhabit. The capacity of these species to cope with fire is a critical consideration for land management and conservation strategies in the locations where they are found. Survival of E. atala pupae in relation to temperature and duration of heat pulse was tested using controlled water bath experiments and a series of prescribed fire field experiments. Survival of E. atala pupae was correlated to peak temperature and heat exposure in both laboratory and field trials. In addition, E. atala survival following field trials was correlated to depth of burial; complete mortality was observed for pupae at the soil surface. Fifty percent of E. atala survived the heat generated by prescribed fire when experimentally placed at depths ≥ 1.75 cm, suggesting that pupation of butterflies in the soil at depth can protect from fatal temperatures caused by fire. For a species such as E. atala that pupates above ground, a population reduction from a burn event is a significant loss, and so decreasing the impact of prescribed fire on populations is critical.

  19. Fire protection

    International Nuclear Information System (INIS)

    Janetzky, E.

    1980-01-01

    Safety and fire prevention measurements have to be treated like the activities developing, planning, construction and erection. Therefore it is necessary that these measurements have to be integrated into the activities mentioned above at an early stage in order to guarantee their effectiveness. With regard to fire accidents the statistics of the insurance companies concerned show that the damage caused increased in the last years mainly due to high concentration of material. Organization of fire prevention and fire fighting, reasons of fire break out, characteristics and behaviour of fire, smoke and fire detection, smoke and heat venting, fire extinguishers (portable and stationary), construction material in presence of fire, respiratory protection etc. will be discussed. (orig./RW)

  20. Influence of Fire Mosaics, Habitat Characteristics and Cattle Disturbance on Mammals in Fire-Prone Savanna Landscapes of the Northern Kimberley.

    Directory of Open Access Journals (Sweden)

    Ian J Radford

    Full Text Available Patch mosaic burning, in which fire is used to produce a mosaic of habitat patches representative of a range of fire histories ('pyrodiversity', has been widely advocated to promote greater biodiversity. However, the details of desired fire mosaics for prescribed burning programs are often unspecified. Threatened small to medium-sized mammals (35 g to 5.5 kg in the fire-prone tropical savannas of Australia appear to be particularly fire-sensitive. Consequently, a clear understanding of which properties of fire mosaics are most instrumental in influencing savanna mammal populations is critical. Here we use mammal capture data, remotely sensed fire information (i.e. time since last fire, fire frequency, frequency of late dry season fires, diversity of post-fire ages in 3 km radius, and spatial extent of recently burnt, intermediate and long unburnt habitat and structural habitat attributes (including an index of cattle disturbance to examine which characteristics of fire mosaics most influence mammals in the north-west Kimberley. We used general linear models to examine the relationship between fire mosaic and habitat attributes on total mammal abundance and richness, and the abundance of the most commonly detected species. Strong negative associations of mammal abundance and richness with frequency of late dry season fires, the spatial extent of recently burnt habitat (post-fire age <1 year within 3 km radius and level of cattle disturbance were observed. Shrub cover was positively related to both mammal abundance and richness, and availability of rock crevices, ground vegetation cover and spatial extent of ≥4 years unburnt habitat were all positively associated with at least some of the mammal species modelled. We found little support for diversity of post-fire age classes in the models. Our results indicate that both a high frequency of intense late dry season fires and extensive, recently burnt vegetation are likely to be detrimental to

  1. Burn Severities, Fire Intensities, and Impacts to Major Vegation Types from the Cerro Grande Fire

    International Nuclear Information System (INIS)

    Balice, R.G.; Bennett, K.D.; Wright, M.A.

    2005-01-01

    The Cerro Grande Fire resulted in major impacts and changes to the ecosystems that were burned. To partially document these effects, we estimated the acreage of major vegetation types that were burned at selected burn severity levels and fire intensity levels. To accomplish this, we adopted independently developed burn severity and fire intensity maps, in combination with a land cover map developed for habitat management purposes, as a basis for the analysis. To provide a measure of confidence in the acreage estimates, the accuracies of these maps were also assessed. In addition, two other maps of comparable quality were assessed for accuracy: one that was developed for mapping fuel risk and a second map that resulted from a preliminary application of an evolutionary computation software system, called GENIE. According to the burn severity map and the fire intensity map, the Cerro Grande Fire is estimated to have covered 42,885.4 acres and 42,854.7 acres, respectively. Of this, 57.0 percent was burned at low severity and 34.7 percent was burned at high severity. Similarly, 40.0 percent of the Cerro Grande Fire burned at high fire intensity, greater than 70 percent mortality, while 33.1 percent burned at moderately low intensity, 10 to 40 percent mortality. The most frequently burned cover types over the entire Cerro Grande Fire were ponderosa pine forest and mixed conifer forest, at approximately 43 percent each. However, portions of the fire that burned on Los Alamos National Laboratory (LANL) property were predominantly in ponderosa pine forests, whereas the Cerro Grande Fire burned primarily in mixed conifer forests on lands managed by other agencies. Some of the polygons of burn severities and fire intensities were extensive. The two largest burn severity polygons were 10,111 acres and 10,903 acres and these were burned at low severity. The next two largest polygons were 8999 acres (14 square miles) and 1551 acres (2.4 square miles) and both of these polygons

  2. Physicochemical properties of aerosol released in the case of a fire involving materials used in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Ouf, F.-X., E-mail: francois-xavier.ouf@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA/LPMA, PSN-RES/SCA/LECEV, Gif-Sur-Yvette 91192 (France); Mocho, V.-M.; Pontreau, S.; Wang, Z. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSN-RES/SCA/LPMA, PSN-RES/SCA/LECEV, Gif-Sur-Yvette 91192 (France); Ferry, D. [Aix-Marseille Université, CNRS UMR 7325, CINaM, 13009 Marseille (France); Yon, J. [CORIA-UMR 6614-Normandie Université, CNRS-Université et Insa de Rouen, Campus Universitaire du Madrillet, 76800 Saint-Etienne-du-Rouvray (France)

    2015-02-11

    Graphical abstract: - Highlights: • We characterize the aerosol emitted during thermal degradation of common materials. • Oxygen concentration on aerosol properties has been investigated. • Influence of oxygen concentration is limited to the organic carbon fraction. • The organic carbon fraction is correlated to the C:H ratio. • For pure materials, monomer diameter is correlated to the emission factor. - Abstract: For industrial concerns, and more especially for nuclear applications, the characterization of soot is essential for predicting the behaviour of containment barriers in fire conditions. This study deals with the characterization (emission factor, composition, size, morphology, microstructure) of particles produced during thermal degradation of materials found in nuclear facilities (electrical cables, polymers, oil and solvents). Small-scale experiments have been conducted for oxygen concentrations [O{sub 2}] ranging from 15% to 21% in order to imitate the oxygen depletion encountered during a confined fire. Particles denote distinct shapes, from aggregates composed of monomers with diameters ranging from 31.2 nm to 52.8 nm, to compact nanoparticles with diameters ranging from 15 nm to 400 nm, and their composition strongly depends on fuel type. Despite the organic to total carbon ratio (OC/TC), their properties are poorly influenced by the decrease in [O{sub 2}]. Finally, two empirical correlations are proposed for predicting the OC/TC ratio and the monomer diameter, respectively, as a function of the fuel's carbon to hydrogen ratio and the emission factor.

  3. A new design method for industrial portal frames in fire

    OpenAIRE

    Song, YY; Huang, Z; Burgess, IW; Plank, RJ

    2009-01-01

    For single-storey steel portal frames in fire, especially when they are situated close to a site perimeter, it is imperative that the boundary walls stay close to vertical, so that fires which occur are not allowed to spread to adjacent properties. A current UK fire design guide requires either that the whole frame be protected as a single element, or that the rafter may be left unprotected if column bases and foundations are designed to resist the forces and moments generated by rafter colla...

  4. Soil properties in fire-consumed log burnout openings in a Missouri oak savanna

    Science.gov (United States)

    Charles C. Rhoades; A. J. Meier; A. J. Rebertus

    2004-01-01

    Downed logs are known to increase species diversity in many forest ecosystems by increasing resource and structural complexity and by altering fire behavior in fire-prone ecosystems. In a frequently burned oak savanna in central Missouri, combustion of downed logs formed patches that have remained free of herbaceous vegetation for more than 3 years. To assess the...

  5. Fire in the Earth System: Bridging data and modeling research

    Science.gov (United States)

    Hantson, Srijn; Kloster, Silvia; Coughlan, Michael; Daniau, Anne-Laure; Vanniere, Boris; Bruecher, Tim; Kehrwald, Natalie; Magi, Brian I.

    2016-01-01

    Significant changes in wildfire occurrence, extent, and severity in areas such as western North America and Indonesia in 2015 have made the issue of fire increasingly salient in both the public and scientific spheres. Biomass combustion rapidly transforms land cover, smoke pours into the atmosphere, radiative heat from fires initiates dramatic pyrocumulus clouds, and the repeated ecological and atmospheric effects of fire can even impact regional and global climate. Furthermore, fires have a significant impact on human health, livelihoods, and social and economic systems.Modeling and databased methods to understand fire have rapidly coevolved over the past decade. Satellite and ground-based data about present-day fire are widely available for applications in research and fire management. Fire modeling has developed in part because of the evolution in vegetation and Earth system modeling efforts, but parameterizations and validation are largely focused on the present day because of the availability of satellite data. Charcoal deposits in sediment cores have emerged as a powerful method to evaluate trends in biomass burning extending back to the Last Glacial Maximum and beyond, and these records provide a context for present-day fire. The Global Charcoal Database version 3 compiled about 700 charcoal records and more than 1,000 records are expected for the future version 4. Together, these advances offer a pathway to explore how the strengths of fire data and fire modeling could address the weaknesses in the overall understanding of human-climate–fire linkages.A community of researchers studying fire in the Earth system with individual expertise that included paleoecology, paleoclimatology, modern ecology, archaeology, climate, and Earth system modeling, statistics, geography, biogeochemistry, and atmospheric science met at an intensive workshop in Massachusetts to explore new research directions and initiate new collaborations. Research themes, which emerged from

  6. Influence of expandable graphite on fire resistance and water resistance of flame-retardant coatings

    International Nuclear Information System (INIS)

    Wang, Zhenyu; Han, Enhou; Ke, Wei

    2007-01-01

    Expandable graphite (EG) coating and ammonium polyphosphate-pentaerythritol-melamine (APP-PER-MEL) coating were prepared. Thermal degradation and char formation of the coatings were investigated by differential thermal analysis (DTA), thermogravimetry (TG), X-ray diffraction (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The results have shown that the anti-oxidation and fire-resistant properties of expandable graphite coating containing EG with size of 74 μm are better than those of APP-PER-MEL coating. The static immersion test was applied to study water resistance of the coatings, and the fire protection test and mechanical test were used to analyse heat insulation and mechanical properties of coatings before and after water immersion. The fire-resistant and mechanical properties of APP-PER-MEL coating were severely damaged by water immersion, whereas EG coating containing 8.5% EG with size of 74 μm could retain the good fire resistance even after 500 h water immersion

  7. Constructive fire protection of steel corrugated beams of buildings and other structures

    Directory of Open Access Journals (Sweden)

    Ilyin Nikolay

    2017-01-01

    Full Text Available The research introduces a methodology of establishing indicators of fire safety of a building in relation to a guaranteed duration of steel fire-proof corrugated beams resistance in conditions of standard fire tests. Indicators of fire safety are also established in the assessment of design limits of steel fire-proof corrugated beams during design process, construction or maintenance of the building as well as in reducing economic costs when testing steel structures for fire resisting property. The suggested methodology introduces the system of actions aimed to design constructive fire protection of steel corrugated beams of buildings. Technological effect is achieved by conducting firing tests of steel construction by non-destructive methods; the evaluation of fire resistance of fire-proof elements of corrugated beams (corrugated web, upper and lower shelves is identified by the least fire-proof element of a welded I-beam. In this methodology fire resistance duration of the constituent elements of a welded I-beam with account of its fire protection ability is described with an analytic function taken as variables. These variables are intensity strength of stresses and the degree of fire protection of a compound element.

  8. Evidence of fuels management and fire weather influencing fire severity in an extreme fire event.

    Science.gov (United States)

    Lydersen, Jamie M; Collins, Brandon M; Brooks, Matthew L; Matchett, John R; Shive, Kristen L; Povak, Nicholas A; Kane, Van R; Smith, Douglas F

    2017-10-01

    Following changes in vegetation structure and pattern, along with a changing climate, large wildfire incidence has increased in forests throughout the western United States. Given this increase, there is great interest in whether fuels treatments and previous wildfire can alter fire severity patterns in large wildfires. We assessed the relative influence of previous fuels treatments (including wildfire), fire weather, vegetation, and water balance on fire-severity in the Rim Fire of 2013. We did this at three different spatial scales to investigate whether the influences on fire severity changed across scales. Both fuels treatments and previous low to moderate-severity wildfire reduced the prevalence of high-severity fire. In general, areas without recent fuels treatments and areas that previously burned at high severity tended to have a greater proportion of high-severity fire in the Rim Fire. Areas treated with prescribed fire, especially when combined with thinning, had the lowest proportions of high severity. The proportion of the landscape burned at high severity was most strongly influenced by fire weather and proportional area previously treated for fuels or burned by low to moderate severity wildfire. The proportion treated needed to effectively reduce the amount of high severity fire varied by spatial scale of analysis, with smaller spatial scales requiring a greater proportion treated to see an effect on fire severity. When moderate and high-severity fire encountered a previously treated area, fire severity was significantly reduced in the treated area relative to the adjacent untreated area. Our results show that fuels treatments and low to moderate-severity wildfire can reduce fire severity in a subsequent wildfire, even when burning under fire growth conditions. These results serve as further evidence that both fuels treatments and lower severity wildfire can increase forest resilience. © 2017 by the Ecological Society of America.

  9. properties of fired bodies made from tanzanian talc- clay mixes

    African Journals Online (AJOL)

    Mgina

    Furthermore, the percentage shrinkage of the fired crisp bodies was found to increase with temperature. ... mixes having the highest percentage of clay showed the highest amount of shrinkage. In general, ..... BGS Technical Report. WG /931/1.

  10. Social and Biophysical Predictors of Public Perceptions of Extreme Fires

    Science.gov (United States)

    Hall, T. E.; Kooistra, C. M.; Paveglio, T.; Gress, S.; Smith, A. M.

    2013-12-01

    To date, what constitutes an 'extreme' fire has been approached separately by biophysical and social scientists. Research on the biophysical characteristics of fires has identified potential dimensions of extremity, including fire size and vegetation mortality. On the social side, factors such as the degree of immediate impact to one's life and property or the extent of social disruption in the community contribute to a perception of extremity. However, some biophysical characteristics may also contribute to perceptions of extremity, including number of simultaneous ignitions, rapidity of fire spread, atypical fire behavior, and intensity of smoke. Perceptions of these impacts can vary within and across communities, but no studies to date have investigated such perceptions in a comprehensive way. In this study, we address the question, to what extent is the magnitude of impact of fires on WUI residents' well-being explained by measurable biophysical characteristics of the fire and subjective evaluations of the personal and community-level impacts of the fire? We bring together diverse strands of psychological theory, including landscape perception, mental models, risk perception, and community studies. The majority of social science research on fires has been in the form of qualitative case studies, and our study is methodologically unique by using a nested design (hierarchical modeling) to enable generalizable conclusions across a wide range of fires and human communities. We identified fires that burned in 2011 or 2012 in the northern Rocky Mountain region that were at least 1,000 acres and that intersected (within 15 km) urban clusters or identified Census places. For fires where an adequately large number of households was located in proximity to the fire, we drew random samples of approximately 150 individuals for each fire. We used a hybrid internet (Qualtrics) and mail survey, following the Dillman method, to measure individual perceptions. We developed two

  11. Analysis of factors influencing fire damage to concrete using nonlinear resonance vibration method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gang Kyu; Park, Sun Jong; Kwak, Hyo Gyoung [Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, KAIST, Daejeon (Korea, Republic of); Yim, Hong Jae [Dept. of Construction and Disaster Prevention Engineering, Kyungpook National University, Sangju (Korea, Republic of)

    2015-04-15

    In this study, the effects of different mix proportions and fire scenarios (exposure temperatures and post-fire-curing periods) on fire-damaged concrete were analyzed using a nonlinear resonance vibration method based on nonlinear acoustics. The hysteretic nonlinearity parameter was obtained, which can sensitively reflect the damage level of fire-damaged concrete. In addition, a splitting tensile strength test was performed on each fire-damaged specimen to evaluate the residual property. Using the results, a prediction model for estimating the residual strength of fire-damaged concrete was proposed on the basis of the correlation between the hysteretic nonlinearity parameter and the ratio of splitting tensile strength.

  12. Does fire affect amphibians and reptiles in eastern U.S. oak forests?

    Science.gov (United States)

    Rochelle B. Renken

    2006-01-01

    Current information about the effect of fire on amphibians and reptiles in oak forests of the Eastern and Central United States is reviewed. Current data suggest that fire results in little direct mortality of amphibians and reptiles. Fire has no effect on overall amphibian abundance, diversity, and number of species in comparisons of burned and unburned plots, though...

  13. Repeated experimental fires and window of disturbance in relation to runoff in a Mediterranean shrubland

    Directory of Open Access Journals (Sweden)

    E. Gimeno-García

    2013-05-01

    Full Text Available This study is focused on exploring the effect of repeated experimental fires on post-fire runoff generation through a sixteen years monitoring runoff yield from erosion plots (eight years after the first fire and other eight years after the second one in a Mediterranean shrubland area (La Concordia Experimental Station, considering the fire severity and the post-fire erosive rainfall events. The conceptual framework of the window of disturbance is used to analyze how long the runoff yield in burned plots shows clear differences respect to the unburned ones, as well as, the recovery-rate model for multiple fire events. Results show that the effect of repeated fires on runoff yield is related to a combination of fire severity, climatic conditions (mainly rainfall intensity, I30, soil hydrological properties (infiltration capacity, steady state infiltration and soil water retention capacity, and rate of vegetation recovery. Eight years after the first fire, even though soil hydrological properties are recovered as well as vegetation cover did, rainfall events with I30 ≥20 mm h-1 still promoted differences between burned and control plots. The second post-fire disturbance period was associated with the low vegetation recovery, and also with rainfall events with I30 ≥20 mm h-1 even seven years after the repeated fires.

  14. Firing patterns of spontaneously active motor units in spinal cord-injured subjects.

    Science.gov (United States)

    Zijdewind, Inge; Thomas, Christine K

    2012-04-01

    Involuntary motor unit activity at low rates is common in hand muscles paralysed by spinal cord injury. Our aim was to describe these patterns of motor unit behaviour in relation to motoneurone and motor unit properties. Intramuscular electromyographic activity (EMG), surface EMG and force were recorded for 30 min from thenar muscles of nine men with chronic cervical SCI. Motor units fired for sustained periods (>10 min) at regular (coefficient of variation ≤ 0.15, CV, n =19 units) or irregular intervals (CV>0.15, n =14). Regularly firing units started and stopped firing independently suggesting that intrinsic motoneurone properties were important for recruitment and derecruitment. Recruitment (3.6 Hz, SD 1.2), maximal (10.2 Hz, SD 2.3, range: 7.5-15.4 Hz) and derecruitment frequencies were low (3.3 Hz, SD 1.6), as were firing rate increases after recruitment (~20 intervals in 3 s). Once active, firing often covaried, promoting the idea that units received common inputs.Half of the regularly firing units showed a very slow decline (>40 s) in discharge before derecruitment and had interspike intervals longer than their estimated after hyperpolarisation potential (AHP) duration (estimated by death rate and breakpoint analyses). The other units were derecruited more abruptly and had shorter estimated AHP durations. Overall, regularly firing units had longer estimated AHP durations and were weaker than irregularly firing units, suggesting they were lower threshold units. Sustained firing of units at regular rates may reflect activation of persistent inward currents, visible here in the absence of voluntary drive, whereas irregularly firing units may only respond to synaptic noise.

  15. Fire hazard analysis for Plutonium Finishing Plant complex

    International Nuclear Information System (INIS)

    MCKINNIS, D.L.

    1999-01-01

    A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41, Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards

  16. Application of Paste Backfill in Underground Coal Fires

    Science.gov (United States)

    Masniyom, M.; Drebenstedt, C.

    2009-04-01

    Coal fires are known from different coalfields worldwide. China, India, USA, Australia, Indonesia and South Africa are the main countries affected by coal fires. The fires is thermally intensive and cause numerous sinkholes, large-scale subsidence, air pollution, global warming, loss of mining productivity and increasing safety risk. The Wuda Inner Mongolia coalfield has been selected as a possible test area for paste backfill. The traditional methods, executed by fire fighting teams, by covering the coalfire areas with soil, blasting burning coal outcrops and injecting water in the subsurface fire pockets are continuously improved and extended. Initiatives to introduce modern techniques, such as backfill placement at fracture and borehole, to cool down the burning coal and cut off the air supply. This study is to investigate backfill materials and techniques suited for underground coal fires. Laboratory tests were carried out on physical, chemical and mechanical properties of different backfill materials and mixtures thereof. Special attention was paid to materials generated as by-products and other cheaply available materials e.g. fly ash from power plants. There is a good chance that one of the different material mixtures investigated can be used as a technically and economically viable backfill for underground coal fires.

  17. Regional fire monitoring and characterization using global NASA MODIS fire products in dry lands of Central Asia

    Science.gov (United States)

    Loboda, Tatiana V.; Giglio, Louis; Boschetti, Luigi; Justice, Christopher O.

    2012-06-01

    Central Asian dry lands are grass- and desert shrub-dominated ecosystems stretching across Northern Eurasia. This region supports a population of more than 100 million which continues to grow at an average rate of 1.5% annually. Dry steppes are the primary grain and cattle growing zone within Central Asia. Degradation of this ecosystem through burning and overgrazing directly impacts economic growth and food supply in the region. Fire is a recurrent disturbance agent in dry lands contributing to soil erosion and air pollution. Here we provide an overview of inter-annual and seasonal fire dynamics in Central Asia obtained from remotely sensed data. We evaluate the accuracy of the Moderate Resolution Imaging Spectroradiometer (MODIS) global fire products within Central Asian dry lands and use these products to characterize fire occurrence between 2001 and 2009. The results show that on average ˜15 million ha of land burns annually across Central Asia with the majority of the area burned in August and September in grasslands. Fire is used as a common crop residue management practice across the region. Nearly 89% of all burning occurs in Kazakhstan, where 5% and 3% of croplands and grasslands, respectively, are burned annually.

  18. Laboratory fire behavior measurements of chaparral crown fire

    Science.gov (United States)

    C. Sanpakit; S. Omodan; D. Weise; M Princevac

    2015-01-01

    In 2013, there was an estimated 9,900 wildland fires that claimed more than 577,000 acres of land. That same year, about 542 prescribed fires were used to treat 48,554 acres by several agencies in California. Being able to understand fires using laboratory models can better prepare individuals to combat or use fires. Our research focused on chaparral crown fires....

  19. Effects of Preprocessing on Multi-Direction Properties of Aluminum Alloy Cold-Spray Deposits

    Science.gov (United States)

    Rokni, M. R.; Nardi, A. T.; Champagne, V. K.; Nutt, S. R.

    2018-05-01

    The effects of powder preprocessing (degassing at 400 °C for 6 h) on microstructure and mechanical properties of 5056 aluminum deposits produced by high-pressure cold spray were investigated. To investigate directionality of the mechanical properties, microtensile coupons were excised from different directions of the deposit, i.e., longitudinal, short transverse, long transverse, and diagonal and then tested. The results were compared to properties of wrought 5056 and the coating deposited with as-received 5056 Al powder and correlated with the observed microstructures. Preprocessing softened the particles and eliminated the pores within them, resulting in more extensive and uniform deformation upon impact with the substrate and with underlying deposited material. Microstructural characterization and finite element simulation indicated that upon particle impact, the peripheral regions experienced more extensive deformation and higher temperatures than the central contact zone. This led to more recrystallization and stronger bonding at peripheral regions relative to the contact zone area and yielded superior properties in the longitudinal direction compared with the short transverse direction. Fractography revealed that crack propagation takes place along the particle-particle interfaces in the transverse directions (caused by insufficient bonding and recrystallization), whereas through the deposited particles, fracture is dominant in the longitudinal direction.

  20. Wildland fire in ecosystems: effects of fire on flora

    Science.gov (United States)

    James K. Brown; Jane Kapler Smith

    2000-01-01

    VOLUME 2: This state-of-knowledge review about the effects of fire on flora and fuels can assist land managers with ecosystem and fire management planning and in their efforts to inform others about the ecological role of fire. Chapter topics include fire regime classification, autecological effects of fire, fire regime characteristics and postfire plant community...

  1. Effects of prescribed fire and post-fire rainfall on mercury mobilization and subsequent contamination assessment in a legacy mine site in Victoria, Australia.

    Science.gov (United States)

    Abraham, Joji; Dowling, Kim; Florentine, Singarayer

    2018-01-01

    Prescribed fire conducted in fire-prone areas is a cost-effective choice for forest management, but it also affects many of the physicochemical and bio-geological properties of the forest soil, in a similar manner to wild fires. The aim of this study is to investigate the nature of the mercury mobilization after a prescribed fire and the subsequent temporal changes in concentration. A prescribed fire was conducted in a legacy mine site in Central Victoria, Australia, in late August 2015 and soil sample collection and analyses were carried out two days before and two days after the fire, followed by collection at the end of each season and after an intense rainfall event in September 2016. Results revealed the occurrence of mercury volatilization (8.3-97%) during the fire, and the mercury concentration displayed a significant difference (p fire. Integrated assessment with number of pollution indices has shown that the study site is extremely contaminated with mercury during all the sampling events, and this poses a serious ecological risk due to the health impacts of mercury on human and ecosystems. In times of climate fluctuation with concomitant increase in forest fire (including prescribed fire), and subsequent precipitation and runoff, the potential for an increased amount of mercury being mobilized is of heighted significance. Therefore, it is recommended that prescribed fire should be cautiously considered as a forest management strategy in any mercury affected landscapes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Changes in marsh soils for six months after a fire

    International Nuclear Information System (INIS)

    Schmalzer, P.A.; Hinkle, C.R.; Koller, A.M. Jr.

    1991-01-01

    In this study, the authors examined changes in the soil nutrient levels in marsh systems after fire. These studies were conducted in conjunction with studies of particulates and gases generated from biomass combustion and flux measures of methane and nitric oxide before and after the fire. Here data are presented through six months postfire, past the time during which flux measurements were made. These data indicate that changes in soil properties occur at different times after the fire and persist for different intervals, indicating the need for long-term postfire observations

  3. Adsorber fires

    International Nuclear Information System (INIS)

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  4. Direct Seeding of Pinus halepensis Mill. for Recovery of Burned Semi-Arid Forests: Implications for Post-Fire Management for Improving Natural Regeneration

    Directory of Open Access Journals (Sweden)

    Francisco Antonio García-Morote

    2017-09-01

    Full Text Available Background: In order to maximize the resiliency of Pinus halepensis in semiarid forests, we analyzed direct seeding methods to recover burned stands by simulating post-fire soil treatments. Methods: Seeding was done by installing spot seeding (100 seeds in a 50 × 50 cm plot, using five methods: (1 covering seeding with wood chips; (2 seeding in branch piles; (3 seeding along trunks on contour-felled logs (on the shaded side; (4 seeding next to grass (Stipa tenacissima; and (5 seeding on the bare ground (control. The experiment was replicated according to aspect (northern and southern aspects. The response variables were seed germination (%, and seedling survival after the summer (measured in autumn 2015 and 2016. Direct seeding was carried out in 32 plots with 160-spot seeding, and data were analyzed using general linear models, including nested random effects. Results: Wood chips as a surface-covering material represented the only treatment that significantly improved seed germination and seedling survival (by 12.4%, and 17.4 seedlings m−2 in year 2, respectively compared with the control in the two topographic aspects. Conclusions: Covering seeding with wood chips, and thus chipping wood within the burned stand, form a recommended post-fire treatment to improve regeneration in Pinus halepensis semiarid stands.

  5. Advancing dendrochronological studies of fire in the United States

    Science.gov (United States)

    Harley, Grant L.; Baisan, Christopher H.; Brown, Peter M.; Falk, Donald A.; Flatley, William T.; Grissino-Mayer, Henri D.; Hessl, Amy; Heyerdahl, Emily K.; Kaye, Margot W.; Lafon, Charles W.; Margolis, Ellis; Maxwell, R. Stockton; Naito, Adam T.; Platt, William J.; Rother, Monica T.; Saladyga, Thomas; Sherriff, Rosemary L.; Stachowiak, Lauren A.; Stambaugh, Michael C.; Sutherland, Elaine Kennedy; Taylor, Alan H.

    2018-01-01

    Dendroecology is the science that dates tree rings to their exact calendar year of formation to study processes that influence forest ecology (e.g., Speer 2010, Amoroso et al., 2017). Reconstruction of past fire regimes is a core application of dendroecology, linking fire history to population dynamics and climate effects on tree growth and survivorship. Since the early 20th century when dendrochronologists recognized that tree rings retained fire scars (e.g., Figure 1), and hence a record of past fires, they have conducted studies worldwide to reconstruct the historical range and variability of fire regimes (e.g., frequency, severity, seasonality, spatial extent), the influence of fire regimes on forest structure and ecosystem dynamics, and the top-down (e.g., climate) and bottom-up (e.g., fuels, topography) drivers of fire that operate at a range of temporal and spatial scales. As in other scientific fields, continued application of dendrochronological techniques to study fires has shaped new trajectories for the science. Here we highlight some important current directions in the United States (US) and call on our international colleagues to continue the conversation with perspectives from other countries.

  6. Landscape fragmentation, severe drought, and the new Amazon forest fire regime.

    Science.gov (United States)

    Alencar, Ane A; Brando, Paulo M; Asner, Gregory P; Putz, Francis E

    2015-09-01

    Changes in weather and land use are transforming the spatial and temporal characteristics of fire regimes in Amazonia, with important effects on the functioning of dense (i.e., closed-canopy), open-canopy, and transitional forests across the Basin. To quantify, document, and describe the characteristics and recent changes in forest fire regimes, we sampled 6 million ha of these three representative forests of the eastern and southern edges of the Amazon using 24 years (1983-2007) of satellite-derived annual forest fire scar maps and 16 years of monthly hot pixel information (1992-2007). Our results reveal that changes in forest fire regime properties differentially affected these three forest types in terms of area burned and fire scar size, frequency, and seasonality. During the study period, forest fires burned 15% (0.3 million ha), 44% (1 million ha), and 46% (0.6 million ha) of dense, open, and transitional forests, respectively. Total forest area burned and fire scar size tended to increase over time (even in years of average rainfall in open canopy and transitional forests). In dense forests, most of the temporal variability in fire regime properties was linked to El Nino Southern Oscillation (ENSO)-related droughts. Compared with dense forests, transitional and open forests experienced fires twice as frequently, with at least 20% of these forests' areas burning two or more times during the 24-year study period. Open and transitional forests also experienced higher deforestation rates than dense forests. During drier years, the end of the dry season was delayed by about a month, which resulted in larger burn scars and increases in overall area burned later in the season. These observations suggest that climate-mediated forest flammability is enhanced by landscape fragmentation caused by deforestation, as observed for open and transitional forests in the Eastern portion of the Amazon Basin.

  7. Proximity to vacant buildings is associated with increased fire risk in Baltimore, Maryland, homes.

    Science.gov (United States)

    Schachterle, Stephen E; Bishai, David; Shields, Wendy; Stepnitz, Rebecca; Gielen, Andrea C

    2012-04-01

    Fires and burns are a leading cause of unintentional injury death in the USA. Although it has been anecdotally reported that vacant dwellings are at a higher risk for fire, the association between vacancy and fire risk at the individual household level has not been empirically measured. In this cross-sectional study, geocoded residential vacant properties (VP) and fire events are analysed in Baltimore City at the census tract level and the individual household level. On average, a 10% increase in the proportion of vacancies in a census tract was associated with a 9.9% increase in fires (95% CI: 5% to 15%). Random-effects Poisson models, controlling for housing and neighbourhood conditions, found contagion effects. The risk of fire in an occupied dwelling increased by 8% (95% CI: 1% to 10%) for every vacant structure within 10 m, and the risk of fire decreased by half (95% CI: 45% to 62%) for every km between an occupied dwelling and vacant building. Close proximity to VP was associated with trash fires within dwellings (p=0.039) and structure fires (p=0.012). We believe that this is the first study to demonstrate increased risk posed by nearby VP at the household level, confirming earlier ecological analyses of the role of VP as strong correlates of home fires. Measurement of this risk can motivate property owners, policy makers and insurers to invest in risk reduction measures that include building maintenance and trash removal.

  8. OCULUS fire: a command and control system for fire management with crowd sourcing and social media interconnectivity

    Science.gov (United States)

    Thomopoulos, Stelios C. A.; Kyriazanos, Dimitris M.; Astyakopoulos, Alkiviadis; Dimitros, Kostantinos; Margonis, Christos; Thanos, Giorgos Konstantinos; Skroumpelou, Katerina

    2016-05-01

    AF3 (Advanced Forest Fire Fighting2) is a European FP7 research project that intends to improve the efficiency of current fire-fighting operations and the protection of human lives, the environment and property by developing innovative technologies to ensure the integration between existing and new systems. To reach this objective, the AF3 project focuses on innovative active and passive countermeasures, early detection and monitoring, integrated crisis management and advanced public information channels. OCULUS Fire is the innovative control and command system developed within AF3 as a monitoring, GIS and Knowledge Extraction System and Visualization Tool. OCULUS Fire includes (a) an interface for real-time updating and reconstructing of maps to enable rerouting based on estimated hazards and risks, (b) processing of GIS dynamic re-construction and mission re-routing, based on the fusion of airborne, satellite, ground and ancillary geolocation data, (c) visualization components for the C2 monitoring system, displaying and managing information arriving from a variety of sources and (d) mission and situational awareness module for OCULUS Fire ground monitoring system being part of an Integrated Crisis Management Information System for ground and ancillary sensors. OCULUS Fire will also process and visualise information from public information channels, social media and also mobile applications by helpful citizens and volunteers. Social networking, community building and crowdsourcing features will enable a higher reliability and less false alarm rates when using such data in the context of safety and security applications.

  9. CCDP evaluation of the fire areas of KSNP using CFAST

    International Nuclear Information System (INIS)

    Lee, Yoon Hwan; Yang, Joon Eon; Kim, Jong Hoon

    2005-01-01

    During the past decade, the nuclear power industry has been moving away from prescriptive rules and practices toward risk-informed and performance-based engineering analysis to support the decision making for plant fire protection programs. For example, the National Fire Protection Association (NFPA) prepared NFPA 805, Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants 2001 Edition. One crucial element in supporting the risk-informed fire protection is availability of simple and reliable methods and tools for evaluating the likelihood and consequences of fire scenarios. These tools directly benefit risk-informed and performance-based fire protection and application of risk information to resolve fire protection issues. Now the deterministic analysis results for the cable integrity is not given in case of performing the fire PSA. So it is necessary to apply the results for the fire modeling to the fire PSA model to develop the more realistic model. This document is intended to analyze the peak temperature of the upper gas layer using the fire modeling code, CFAST , to evaluate the integrity of the cable located on the dominant pump rooms, and to assess the CCDP(Conditional Core Damage Probability) using the results of the cable integrity. Accordingly, the fire safety assessment for the dominant fire areas using the fire modeling code will be capable of evaluating the consequences of the fire scenario, of reducing the the uncertainty, and to develop a more realistic model

  10. Putting out fire with gasoline: pitfalls in the silvicultural treatment of canopy fuels

    Science.gov (United States)

    Christopher R. Keyes; J. Morgan Varner

    2007-01-01

    There is little question that forest stand structure is directly related to fire behavior, and that canopy fuel structure may be altered using silvicultural methods to successfully modify forest fire behavior and reduce susceptibility to crown fire initiation and spread. Silvicultural treatments can remediate hazardous stand structures that have developed as a result...

  11. GABAB-receptor activation alters the firing pattern of dopamine neurons in the rat substantia nigra.

    Science.gov (United States)

    Engberg, G; Kling-Petersen, T; Nissbrandt, H

    1993-11-01

    Previous electrophysiological experiments have emphasized the importance of the firing pattern for the functioning of midbrain dopamine (DA) neurons. In this regard, excitatory amino acid receptors appear to constitute an important modulatory control mechanism. In the present study, extracellular recording techniques were used to investigate the significance of GABAB-receptor activation for the firing properties of DA neurons in the substantia nigra (SN) in the rat. Intravenous administration of the GABAB-receptor agonist baclofen (1-16 mg/kg) was associated with a dose-dependent regularization of the firing pattern, concomitant with a reduction in burst firing. At higher doses (16-32 mg/kg), the firing rate of the DA neurons was dose-dependently decreased. Also, microiontophoretic application of baclofen regularized the firing pattern of nigral DA neurons, including a reduction of burst firing. Both the regularization of the firing pattern and inhibition of firing rate produced by systemic baclofen administration was antagonized by the GABAB-receptor antagonist CGP 35348 (200 mg/kg, i.v.). The GABAA-receptor agonist muscimol produced effects on the firing properties of DA neurons that were opposite to those observed following baclofen, i.e., an increase in firing rate accompanied by a decreased regularity. The NMDA receptor antagonist MK 801 (0.4-3.2 mg/kg, i.v.) produced a moderate, dose-dependent increase in the firing rate of the nigral DA neurons as well as a slightly regularized firing pattern. Pretreatment with MK 801 (3.2 mg/kg, i.v., 3-10 min) did neither promote nor prevent the regularization of the firing pattern or inhibition of firing rate on the nigral DA neurons produced by baclofen. The present results clearly show that GABAB-receptors can alter the firing pattern of nigral DA neurons, hereby counterbalancing the previously described ability of glutamate to induce burst firing activity on these neurons.

  12. Predicting hydrological and erosional risks in fire-affected watersheds: recent advances and research gaps

    Science.gov (United States)

    Nunes, João Pedro; Keizer, Jan Jacob

    2017-04-01

    Models can be invaluable tools to assess and manage the impacts of forest fires on hydrological and erosion processes. Immediately after fires, models can be used to identify priority areas for post-fire interventions or assess the risks of flooding and downstream contamination. In the long term, models can be used to evaluate the long-term implications of a fire regime for soil protection, surface water quality and potential management risks, or determine how changes to fire regimes, caused e.g. by climate change, can impact soil and water quality. However, several challenges make post-fire modelling particularly difficult: • Fires change vegetation cover and properties, such as by changing soil water repellency or by adding an ash layer over the soil; these processes, however are not described in currently used models, so that existing models need to be modified and tested. • Vegetation and soils recover with time since fire, changing important model parameters, so that the recovery processes themselves also need to be simulated, including the role of post-fire interventions. • During the window of vegetation and soil disturbance, particular weather conditions, such as the occurrence of severe droughts or extreme rainfall events, can have a large impact on the amount of runoff and erosion produced in burnt areas, so that models that smooth out these peak responses and rather simulate "long-term" average processes are less useful. • While existing models can simulate reasonable well slope-scale runoff generation and associated sediment losses and their catchment-scale routing, few models can accommodate the role of the ash layer or its transport by overland flow, in spite of its importance for soil fertility losses and downstream contamination. This presentation will provide an overview of the importance of post-fire hydrological and erosion modelling as well as of the challenges it faces and of recent efforts made to overcome these challenges. It will

  13. Stream nitrogen responses to fire in the Southeastern U.S.

    Science.gov (United States)

    James M. Vose; Stephanie H. Laseter; Steve G. McNulty

    2005-01-01

    Fire can play a significant role in runoff, sediment yield, and nitrate transport in aquatic and terrestrial ecosystems in the southeast US. The typical impact of fire is an immediate change in the physical properties of the soil and forest floor surface, followed by mid- and long-term changes in biological pools and cycling processes. Depending upon the severity of...

  14. Risk assessment of main control board fire using fire dynamics simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il, E-mail: dikang@kaeri.re.kr [KAERI, 1045 Daedeokdaero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Kim, Kilyoo; Jang, Seung-Cheol [KAERI, 1045 Daedeokdaero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Yoo, Seong Yeon [Chungnam National University, 79, Daehagro, Yuseong-Gu, Daejeon (Korea, Republic of)

    2015-08-15

    Highlights: • A decision tree for evaluating the risk of a main control board (MCB) fire was proposed to systematically determine the MCB fire scenarios. • Fire simulations using fire dynamics simulator (FDS) were performed to estimate the time to MCR abandonment. • Non-propagating and propagating fire scenarios were considered for fire simulations. • The current study indicates that the quantification of the MCB fire risk should address the propagating fire and non-propagating fire scenarios if the MCB has no internal barriers between the panels. - Abstract: This paper presents the process and results of a risk assessment for a main control board (MCB) fire using fire dynamics simulator (FDS). A decision tree for evaluating the risk of a MCB fire was proposed to systematically determine the MCB fire scenarios, and fire simulations using FDS were performed to estimate the time to MCR abandonment. As a reference NPP for this study, Hanul unit 3 in Korea was selected and its core damage frequency (CDF) owing to the MCB fire was quantified. Two types of fire scenarios were considered for fire simulations: non-propagating fire scenarios occurring within a single MCB panel and propagating fire scenarios spreading from one control panel to the adjacent panels. Further, the fire scenarios were classified into fires with and without a heating, ventilation, and air conditioning system (HVACS). The fire simulation results showed that the major factor causing the MCR evacuation was the optical density irrelevant to the availability of the HVACS. The risk assessment results showed that the abandonment fire scenario risk was less than the non-abandonment fire scenario risk and the propagating fire scenario risk was greater than the non-propagating fire scenario risk.

  15. Risk assessment of main control board fire using fire dynamics simulator

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kilyoo; Jang, Seung-Cheol; Yoo, Seong Yeon

    2015-01-01

    Highlights: • A decision tree for evaluating the risk of a main control board (MCB) fire was proposed to systematically determine the MCB fire scenarios. • Fire simulations using fire dynamics simulator (FDS) were performed to estimate the time to MCR abandonment. • Non-propagating and propagating fire scenarios were considered for fire simulations. • The current study indicates that the quantification of the MCB fire risk should address the propagating fire and non-propagating fire scenarios if the MCB has no internal barriers between the panels. - Abstract: This paper presents the process and results of a risk assessment for a main control board (MCB) fire using fire dynamics simulator (FDS). A decision tree for evaluating the risk of a MCB fire was proposed to systematically determine the MCB fire scenarios, and fire simulations using FDS were performed to estimate the time to MCR abandonment. As a reference NPP for this study, Hanul unit 3 in Korea was selected and its core damage frequency (CDF) owing to the MCB fire was quantified. Two types of fire scenarios were considered for fire simulations: non-propagating fire scenarios occurring within a single MCB panel and propagating fire scenarios spreading from one control panel to the adjacent panels. Further, the fire scenarios were classified into fires with and without a heating, ventilation, and air conditioning system (HVACS). The fire simulation results showed that the major factor causing the MCR evacuation was the optical density irrelevant to the availability of the HVACS. The risk assessment results showed that the abandonment fire scenario risk was less than the non-abandonment fire scenario risk and the propagating fire scenario risk was greater than the non-propagating fire scenario risk

  16. Identifying the location of fire refuges in wet forest ecosystems.

    Science.gov (United States)

    Berry, Laurence E; Driscoll, Don A; Stein, John A; Blanchard, Wade; Banks, Sam C; Bradstock, Ross A; Lindenmayer, David B

    2015-12-01

    The increasing frequency of large, high-severity fires threatens the survival of old-growth specialist fauna in fire-prone forests. Within topographically diverse montane forests, areas that experience less severe or fewer fires compared with those prevailing in the landscape may present unique resource opportunities enabling old-growth specialist fauna to survive. Statistical landscape models that identify the extent and distribution of potential fire refuges may assist land managers to incorporate these areas into relevant biodiversity conservation strategies. We used a case study in an Australian wet montane forest to establish how predictive fire simulation models can be interpreted as management tools to identify potential fire refuges. We examined the relationship between the probability of fire refuge occurrence as predicted by an existing fire refuge model and fire severity experienced during a large wildfire. We also examined the extent to which local fire severity was influenced by fire severity in the surrounding landscape. We used a combination of statistical approaches, including generalized linear modeling, variogram analysis, and receiver operating characteristics and area under the curve analysis (ROC AUC). We found that the amount of unburned habitat and the factors influencing the retention and location of fire refuges varied with fire conditions. Under extreme fire conditions, the distribution of fire refuges was limited to only extremely sheltered, fire-resistant regions of the landscape. During extreme fire conditions, fire severity patterns were largely determined by stochastic factors that could not be predicted by the model. When fire conditions were moderate, physical landscape properties appeared to mediate fire severity distribution. Our study demonstrates that land managers can employ predictive landscape fire models to identify the broader climatic and spatial domain within which fire refuges are likely to be present. It is essential

  17. Effects of fire on major forest ecosystem processes: an overview.

    Science.gov (United States)

    Chen, Zhong

    2006-09-01

    Fire and fire ecology are among the best-studied topics in contemporary ecosystem ecology. The large body of existing literature on fire and fire ecology indicates an urgent need to synthesize the information on the pattern of fire effects on ecosystem composition, structure, and functions for application in fire and ecosystem management. Understanding fire effects and underlying principles are critical to reduce the risk of uncharacteristic wildfires and for proper use of fire as an effective management tool toward management goals. This overview is a synthesis of current knowledge on major effects of fire on fire-prone ecosystems, particularly those in the boreal and temperate regions of the North America. Four closely related ecosystem processes in vegetation dynamics, nutrient cycling, soil and belowground process and water relations were discussed with emphases on fire as the driving force. Clearly, fire can shape ecosystem composition, structure and functions by selecting fire adapted species and removing other susceptible species, releasing nutrients from the biomass and improving nutrient cycling, affecting soil properties through changing soil microbial activities and water relations, and creating heterogeneous mosaics, which in turn, can further influence fire behavior and ecological processes. Fire as a destructive force can rapidly consume large amount of biomass and cause negative impacts such as post-fire soil erosion and water runoff, and air pollution; however, as a constructive force fire is also responsible for maintaining the health and perpetuity of certain fire-dependent ecosystems. Considering the unique ecological roles of fire in mediating and regulating ecosystems, fire should be incorporated as an integral component of ecosystems and management. However, the effects of fire on an ecosystem depend on the fire regime, vegetation type, climate, physical environments, and the scale of time and space of assessment. More ecosystem

  18. Burnthrough Modeling of Marine Grade Aluminum Alloy Structural Plates Exposed to Fire

    OpenAIRE

    Rippe, Christian M

    2015-01-01

    Current fire induced burnthrough models of aluminum typically rely solely on temperature thresholds and cannot accurately capture either the occurrence or the time to burnthrough. This research experimentally explores the fire induced burnthrough phenomenon of AA6061-T651 plates under multiple sized exposures and introduces a new burnthrough model based on the near melting creep rupture properties of the material. Fire experiments to induce burnthrough on aluminum plates were conducted us...

  19. Do agricultural terraces and forest fires recurrence in Mediterranean afforested micro-catchments alter soil quality and soil nutrient content?

    Science.gov (United States)

    E Lucas-Borja, Manuel; Calsamiglia, Aleix; Fortesa, Josep; García-Comendador, Julián; Gago, Jorge; Estrany, Joan

    2017-04-01

    parameters due to land abandonment and the lack of terraced management. In addition, forest fire recurrence exacerbates soil degradation processes due to the direct effects on vegetation and soil properties.

  20. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  1. Fire-Walking

    Science.gov (United States)

    Willey, David

    2010-01-01

    This article gives a brief history of fire-walking and then deals with the physics behind fire-walking. The author has performed approximately 50 fire-walks, took the data for the world's hottest fire-walk and was, at one time, a world record holder for the longest fire-walk (www.dwilley.com/HDATLTW/Record_Making_Firewalks.html). He currently…

  2. Forest-fire models

    Science.gov (United States)

    Haiganoush Preisler; Alan Ager

    2013-01-01

    For applied mathematicians forest fire models refer mainly to a non-linear dynamic system often used to simulate spread of fire. For forest managers forest fire models may pertain to any of the three phases of fire management: prefire planning (fire risk models), fire suppression (fire behavior models), and postfire evaluation (fire effects and economic models). In...

  3. Evaluation of technical feasibility of closed-cycle non-equilibrium MHD power generation with direct coal firing. Final report, Task I

    Energy Technology Data Exchange (ETDEWEB)

    1981-11-01

    Program accomplishments in a continuing effort to demonstrate the feasibility of direct coal-fired, closed-cycle MHD power generation are reported. This volume contains the following appendices: (A) user's manual for 2-dimensional MHD generator code (2DEM); (B) performance estimates for a nominal 30 MW argon segmented heater; (C) the feedwater cooled Brayton cycle; (D) application of CCMHD in an industrial cogeneration environment; (E) preliminary design for shell and tube primary heat exchanger; and (F) plant efficiency as a function of output power for open and closed cycle MHD power plants. (WHK)

  4. Quantifying the effect of fuel reduction treatments on fire behavior in boreal forests

    Science.gov (United States)

    B.W. Butler; R.D. Ottmar; T.S. Rupp; R. Jandt; E. Miller; K. Howard; R. Schmoll; S. Theisen; R.E. Vihnanek; D. Jimenez

    2013-01-01

    Mechanical (e.g., shearblading) and manual (e.g., thinning) fuel treatments have become the preferred strategy of many fire managers and agencies for reducing fire hazard in boreal forests. This study attempts to characterize the effectiveness of four fuel treatments through direct measurement of fire intensity and forest floor consumption during a single prescribed...

  5. Fire Perimeters

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2003. Some fires...

  6. Fire History

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2002. Some fires...

  7. Electronic firing systems and methods for firing a device

    Science.gov (United States)

    Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  8. Thermodynamic properties calculation of the flue gas based on its composition estimation for coal-fired power plants

    International Nuclear Information System (INIS)

    Xu, Liang; Yuan, Jingqi

    2015-01-01

    Thermodynamic properties of the working fluid and the flue gas play an important role in the thermodynamic calculation for the boiler design and the operational optimization in power plants. In this study, a generic approach to online calculate the thermodynamic properties of the flue gas is proposed based on its composition estimation. It covers the full operation scope of the flue gas, including the two-phase state when the temperature becomes lower than the dew point. The composition of the flue gas is online estimated based on the routinely offline assays of the coal samples and the online measured oxygen mole fraction in the flue gas. The relative error of the proposed approach is found less than 1% when the standard data set of the dry and humid air and the typical flue gas is used for validation. Also, the sensitivity analysis of the individual component and the influence of the measurement error of the oxygen mole fraction on the thermodynamic properties of the flue gas are presented. - Highlights: • Flue gas thermodynamic properties in coal-fired power plants are online calculated. • Flue gas composition is online estimated using the measured oxygen mole fraction. • The proposed approach covers full operation scope, including two-phase flue gas. • Component sensitivity to the thermodynamic properties of flue gas is presented.

  9. On MHD waves, fire-hose and mirror instabilities in anisotropic plasmas

    Directory of Open Access Journals (Sweden)

    L.-N. Hau

    2007-09-01

    Full Text Available Temperature or pressure anisotropies are characteristic of space plasmas, standard magnetohydrodynamic (MHD model for describing large-scale plasma phenomena however usually assumes isotropic pressure. In this paper we examine the characteristics of MHD waves, fire-hose and mirror instabilities in anisotropic homogeneous magnetized plasmas. The model equations are a set of gyrotropic MHD equations closed by the generalized Chew-Goldberger-Low (CGL laws with two polytropic exponents representing various thermodynamic conditions. Both ions and electrons are allowed to have separate plasma beta, pressure anisotropy and energy equations. The properties of linear MHD waves and instability criteria are examined and numerical examples for the nonlinear evolutions of slow waves, fire-hose and mirror instabilities are shown. One significant result is that slow waves may develop not only mirror instability but also a new type of compressible fire-hose instability. Their corresponding nonlinear structures thus may exhibit anticorrelated density and magnetic field perturbations, a property used for identifying slow and mirror mode structures in the space plasma environment. The conditions for nonlinear saturation of both fire-hose and mirror instabilities are examined.

  10. Fire weather conditions and fire-atmosphere interactions observed during low-intensity prescribed fires - RxCADRE 2012

    Science.gov (United States)

    Craig B. Clements; Neil P. Lareau; Daisuke Seto; Jonathan Contezac; Braniff Davis; Casey Teske; Thomas J. Zajkowski; Andrew T. Hudak; Benjamin C. Bright; Matthew B. Dickinson; Bret W. Butler; Daniel Jimenez; J. Kevin. Hiers

    2016-01-01

    The role of fire-atmosphere coupling on fire behaviour is not well established, and to date few field observations have been made to investigate the interactions between fire spread and fire-induced winds. Therefore, comprehensive field observations are needed to better understand micrometeorological aspects of fire spread. To address this need, meteorological...

  11. Vorticity and turbulence observations during a wildland fire on sloped terrain

    Science.gov (United States)

    Contezac, J.; Clements, C. B.; Hall, D.; Seto, D.; Davis, B.

    2013-12-01

    Fire-atmosphere interactions represent an atmospheric boundary-layer regime typically associated with complex circulations that interact with the fire front. In mountainous terrain, these interactions are compounded by terrain-driven circulations that often lead to extreme fire behavior. To better understand the role of complex terrain on fire behavior, a set of field experiments was conducted in June 2012 in the Coast Range of central California. The experiments were conducted on steep valley sidewalls to allow fires to spread upslope. Instrumentation used to measure fire-atmosphere interactions included three micrometeorological towers arranged along the slope and equipped with sonic anemometers, heat flux radiometers, and fine-wire thermocouples. In addition, a scanning Doppler lidar was used to measured winds within and above the valley, and airborne video imagery was collected to monitor fire behavior characteristics. The experimental site was located on the leeside of a ridge where terrain-induced flow and opposing mesoscale winds aloft interacted to create a zone of high wind shear. During the burn, the interaction between the fire and atmosphere caused the generation of several fire whirls that develop as a result of several environmental conditions including shear-generated vorticity and fire front geometry. Airborne video imagery indicated that upon ignition, the plume tilted in the opposite direction from the fire movement suggesting that higher horizontal momentum from aloft was brought to the surface, resulting in much slower fire spread rates due to opposing winds. However, after the fire front had passed the lowest tower located at the base of the slope, a shift in wind speed and direction caused a fire whirl to develop near an L-shaped kink in the fire front. Preliminary results indicate that at this time, winds at the bottom of the slope began to rotate with horizontal vorticity values of -0.2 s^-1. Increased heat flux values at this time indicated

  12. Community participation in fire management planning: The Trinity county fire safe council's fire plan

    Science.gov (United States)

    Yvonne Everett

    2008-01-01

    In 1999, Trinity County CA, initiated a participatory fire management planning effort. Since that time, the Trinity County Fire Safe Council has completed critical portions of a fire safe plan and has begun to implement projects defined in the plan. Completion of a GIS based, landscape scale fuels reduction element in the plan defined by volunteer fire fighters, agency...

  13. Advanced analysis of forest fire clustering

    Science.gov (United States)

    Kanevski, Mikhail; Pereira, Mario; Golay, Jean

    2017-04-01

    Analysis of point pattern clustering is an important topic in spatial statistics and for many applications: biodiversity, epidemiology, natural hazards, geomarketing, etc. There are several fundamental approaches used to quantify spatial data clustering using topological, statistical and fractal measures. In the present research, the recently introduced multi-point Morisita index (mMI) is applied to study the spatial clustering of forest fires in Portugal. The data set consists of more than 30000 fire events covering the time period from 1975 to 2013. The distribution of forest fires is very complex and highly variable in space. mMI is a multi-point extension of the classical two-point Morisita index. In essence, mMI is estimated by covering the region under study by a grid and by computing how many times more likely it is that m points selected at random will be from the same grid cell than it would be in the case of a complete random Poisson process. By changing the number of grid cells (size of the grid cells), mMI characterizes the scaling properties of spatial clustering. From mMI, the data intrinsic dimension (fractal dimension) of the point distribution can be estimated as well. In this study, the mMI of forest fires is compared with the mMI of random patterns (RPs) generated within the validity domain defined as the forest area of Portugal. It turns out that the forest fires are highly clustered inside the validity domain in comparison with the RPs. Moreover, they demonstrate different scaling properties at different spatial scales. The results obtained from the mMI analysis are also compared with those of fractal measures of clustering - box counting and sand box counting approaches. REFERENCES Golay J., Kanevski M., Vega Orozco C., Leuenberger M., 2014: The multipoint Morisita index for the analysis of spatial patterns. Physica A, 406, 191-202. Golay J., Kanevski M. 2015: A new estimator of intrinsic dimension based on the multipoint Morisita index

  14. Model of fire spread around Krsko Power Plant

    International Nuclear Information System (INIS)

    Vidmar, P.; Petelin, S.

    2001-01-01

    The idea behind the article is how to define fire behaviour. The work is based on an analytical study of fire origin, its development and spread. The study is based on thermodynamics, heat transfer and the study of hydrodynamics and combustion, which represent the bases of fire dynamics. The article shows a practical example of a leak of hazardous chemicals from a tank. Because of the inflammability of the fluid, fire may start. We have tried to model fire propagation around the Krsko power plant, and show what extended surrounding area could be affected. The model also considers weather conditions, in particular wind speed and direction. For this purpose we have used the computer code Safer Trace, which is based on zone models. That means that phenomena are described by physical and empirical equations. An imperfection in this computer code is the inability to consider ground topology. However in the case of the Krsko power plant, topology is not so important, as the plan is located in a relatively flat region. Mathematical models are presented. They show the propagation of hazardous fluid in the environment considering meteorological data. The work also shows which data are essential to define fire spread and shows the main considerations of Probabilistic Safety Assessment for external fire event.(author)

  15. Fire hazard analysis for Plutonium Finishing Plant complex

    Energy Technology Data Exchange (ETDEWEB)

    MCKINNIS, D.L.

    1999-02-23

    A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41, Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards.

  16. Managing wildland fires: integrating weather models into fire projections

    Science.gov (United States)

    Anne M. Rosenthal; Francis Fujioka

    2004-01-01

    Flames from the Old Fire sweep through lands north of San Bernardino during late fall of 2003. Like many Southern California fires, the Old Fire consumed susceptible forests at the urban-wildland interface and spread to nearby city neighborhoods. By incorporating weather models into fire perimeter projections, scientist Francis Fujioka is improving fire modeling as a...

  17. Behaviour of concrete structures in fire

    Directory of Open Access Journals (Sweden)

    Fletcher Ian A.

    2007-01-01

    Full Text Available This paper provides a "state-of-the-art" review of research into the effects of high temperature on concrete and concrete structures, extending to a range of forms of construction, including novel developments. The nature of concrete-based structures means that they generally perform very well in fire. However, concrete is fundamentally a complex material and its properties can change dramatically when exposed to high temperatures. The principal effects of fire on concrete are loss of compressive strength, and spalling - the forcible ejection of material from the surface of a member. Though a lot of information has been gathered on both phenomena, there remains a need for more systematic studies of the effects of thermal exposures. The response to realistic fires of whole concrete structures presents yet greater challenges due to the interactions of structural elements, the impact of complex small-scale phenomena at full scale, and the spatial and temporal variations in exposures, including the cooling phase of the fire. Progress has been made on modeling the thermomechanical behavior but the treatment of detailed behaviors, including hygral effects and spalling, remains a challenge. Furthermore, there is still a severe lack of data from real structures for validation, though some valuable insights may also be gained from study of the performance of concrete structures in real fires. .

  18. Protection against fire hazards in French nuclear power plants

    International Nuclear Information System (INIS)

    Chapus, J.

    2000-01-01

    The prevention of fire in French nuclear power plants has followed the evolution of safety regulations. Today fire hazards are no longer considered as classical industrial risks but as specific risks that deserve to be studied thoroughly and in a more formalized form. In the beginning of the eighties EDF was committed to the redaction of a technical referential against fire gathering all the directives applicable to the N4-type plant (1450 MW). In 1994 this technical referential was reconsidered and enlarged in order to involve 900 MW and 1300 MW units. In each nuclear power plant a PAI (plan against fire) has been elaborated so that the installation can be progressively upgraded according to the last standard defined by the technical referential. (A.C.)

  19. Enhancing adaptive capacity for restoring fire-dependent ecosystems: the Fire Learning Network's Prescribed Fire Training Exchanges

    Directory of Open Access Journals (Sweden)

    Andrew G. Spencer

    2015-09-01

    Full Text Available Prescribed fire is a critical tool for promoting restoration and increasing resilience in fire-adapted ecosystems, but there are barriers to its use, including a shortage of personnel with adequate ecological knowledge and operational expertise to implement prescribed fire across multijurisdictional landscapes. In the United States, recognized needs for both professional development and increased use of fire are not being met, often because of institutional limitations. The Fire Learning Network has been characterized as a multiscalar, collaborative network that works to enhance the adaptive capacity of fire management institutions, and this network developed the Prescribed Fire Training Exchanges (TREXs to address persistent challenges in increasing the capacity for prescribed fire implementation. Our research was designed to investigate where fire professionals face professional barriers, how the TREX addresses these, and in what ways the TREX may be contributing to the adaptive capacity of fire management institutions. We evaluated the training model using surveys, interviews, focus groups, and participant observation. We found that, although the training events cannot overcome all institutional barriers, they incorporate the key components of professional development in fire; foster collaboration, learning, and network building; and provide flexible opportunities with an emphasis on local context to train a variety of professionals with disparate needs. The strategy also offers an avenue for overcoming barriers faced by contingent and nonfederal fire professionals in attaining training and operational experience, thereby increasing the variety of actors and resources involved in fire management. Although it is an incremental step, the TREX is contributing to the adaptive capacity of institutions in social-ecological systems in which fire is a critical ecological process.

  20. Multifractal analysis of forest fires in complex regions

    Science.gov (United States)

    Vega Orozco, C. D.; Kanevski, M.; Golay, J.; Tonini, M.; Conedera, M.

    2012-04-01

    Forest fires can be studied as point processes where the ignition points represent the set of locations of the observed events in a defined study region. Their spatial and temporal patterns can be characterized by their fractal properties; which quantify the global aspect of the geometry of the support data. However, a monofractal dimension can not completely describe the pattern structure and related scaling properties. Enhancements in fractal theory had developed the multifractal concept which describes the measures from which interlinked fractal sets can be retrieved and characterized by their fractal dimension and singularity strength [1, 2]. The spatial variability of forest fires is conditioned by an intermixture of human, topographic, meteorological and vegetation factors. This heterogeneity makes fire patterns complex scale-invariant processes difficult to be depicted by a single scale. Therefore, this study proposes an exploratory data analysis through a multifractal formalism to characterize and quantify the multiscaling behaviour of the spatial distribution pattern of this phenomenon in a complex region like the Swiss Alps. The studied dataset is represented by 2,401 georeferenced forest fire ignition points in canton Ticino, Switzerland, in a 40-years period from 1969 to 2008. Three multifractal analyses are performed: one assesses the multiscaling behaviour of fire occurrence probability of the support data (raw data) and four random patterns simulated within three different support domains; second analysis studies the multifractal behavior of patterns from anthropogenic and natural ignited fires (arson-, accident- and lightning-caused fires); and third analysis aims at detecting scale-dependency of the size of burned area. To calculate the generalized dimensions, Dq, a generalization of the box counting methods is carried out based on the generalization of Rényi information of the qth order moment of the probability distribution. For q > 0, Dq

  1. Materials Problems and Solutions in Biomass Fired Plants

    DEFF Research Database (Denmark)

    Larsen, Ole Hede; Montgomery, Melanie

    2006-01-01

    ascribed to the composition of the deposit and the metal surface temperature. In woodchip boilers, a similar corrosion rate and corrosion mechanism has on some occasions been observed. Co-firing of straw (10 and 20% energy basis) with coal has shown corrosion rates lower than those in straw-fired plants......Due to Denmark’s pledge to reduce carbon dioxide emissions, biomass is utilised increasingly as a fuel for generating energy. Extensive research and demonstration projects especially in the area of material performance for biomass fired boilers have been undertaken to make biomass a viable fuel...... resource. When straw is combusted, potassium chloride and potassium sulphate are present in ash products, which condense on superheater components. This gives rise to specific chlorine corrosion problems not previously encountered in coal-fired power plants. The type of corrosion attack can be directly...

  2. Surface forcing of non-stand-replacing fires in Siberian larch forests

    Science.gov (United States)

    Chen, Dong; Loboda, Tatiana V.

    2018-04-01

    Wildfires are the dominant disturbance agent in the Siberian larch forests. Extensive low- to mediate-intensity non-stand-replacing fires are a notable property of fire regime in these forests. Recent large scale studies of these fires have focused mostly on their impacts on carbon budget; however, their potential impacts on energy budget through post-fire albedo changes have not been considered. This study quantifies the post-fire surface forcing for Siberian larch forests that experienced non-stand-replacing fires between 2001 and 2012 using the full record of MODIS MCD43A3 albedo product and a burned area product developed specifically for the Russian forests. Despite a large variability, the mean effect of non-stand-replacing fires imposed through albedo is a negative forcing which lasts for at least 14 years. However, the magnitude of the forcing is much smaller than that imposed by stand-replacing fires, highlighting the importance of differentiating between the two fire types in the studies involving the fire impacts in the region. The results of this study also show that MODIS-based summer differenced normalized burn ratio (dNBR) provides a reliable metric for differentiating non-stand-replacing from stand-replacing fires with an overall accuracy of 88%, which is of considerable importance for future work on modeling post-fire energy budget and carbon budget in the region.

  3. Diffusion properties of active particles with directional reversal

    International Nuclear Information System (INIS)

    Großmann, R; Bär, M; Peruani, F

    2016-01-01

    The diffusion properties of self-propelled particles which move at constant speed and, in addition, reverse their direction of motion repeatedly are investigated. The internal dynamics of particles triggering these reversal processes is modeled by a stochastic clock. The velocity correlation function as well as the mean squared displacement is investigated and, furthermore, a general expression for the diffusion coefficient for self-propelled particles with directional reversal is derived. Our analysis reveals the existence of an optimal, finite rotational noise amplitude which maximizes the diffusion coefficient. We comment on the relevance of these results with regard to biological systems and suggest further experiments in this context. (paper)

  4. US Fire Administration Fire Statistics

    Data.gov (United States)

    Department of Homeland Security — The U.S. Fire Administration collects data from a variety of sources to provide information and analyses on the status and scope of the fire problem in the United...

  5. The role of fire in the boreal carbon budget

    Science.gov (United States)

    Harden, J.W.; Trumbore, S.E.; Stocks, B.J.; Hirsch, A.; Gower, S.T.; O'Neill, K. P.; Kasischke, E.S.

    2000-01-01

    To reconcile observations of decomposition rates, carbon inventories, and net primary production (NPP), we estimated long-term averages for C exchange in boreal forests near Thompson, Manitoba. Soil drainage as defined by water table, moss cover, and permafrost dynamics, is the dominant control on direct fire emissions. In upland forests, an average of about 10-30% of annual NPP was likely consumed by fire over the past 6500 years since these landforms and ecosystems were established. This long-term, average fire emission is much larger than has been accounted for in global C cycle models and may forecast an increase in fire activity for this region. While over decadal to century times these boreal forests may be acting as slight net sinks for C from the atmosphere to land, periods of drought and severe fire activity may result in net sources of C from these systems.

  6. Experimental study of fire barriers preventing vertical fire spread in ETISs

    Directory of Open Access Journals (Sweden)

    Xin Huang

    2013-11-01

    Full Text Available In recent years, the external thermal insulation system (ETIS has been applied increasingly in a large amount of buildings for energy conservation purpose. However, the increase use of combustible insulation materials in the ETIS has raised serious fire safety problems. Fires involving this type of ETIS have caused severe damage and loss. In order to improve its fire safety, fire barriers were suggested to be installed. This paper introduces fire experiments that have been done to study the effects of fire barriers on preventing vertical fire spread along the ETIS. The experiments were performed according to BS 8414-1:2002 “Fire performance of external cladding systems – Part 1: Test method for non-loadbearing external cladding systems applied to the face of the building”. The test facility consists of a 9 m high wall. The fire sources were wood cribs with a fire size of 3 ± 0.5 MW. The insulation materials were expanded polystyrene foam (EPS. The fire barrier was a horizontal strip of rockwool with a width of 300 mm. Thermocouples were used to measure temperatures outside and inside the ETIS. A series of experiments with different fire scenarios were done: no fire barrier, two fire barriers and three fire barriers at different heights. Test results were compared. The results show that the ETIS using EPS without fire barriers almost burned out, while the ETIS with fire barriers performed well in preventing fire spread. The temperatures above the fire barrier were much lower than those below the fire barrier, and most of the insulation materials above the top fire barrier stayed in place.

  7. Fire effects on Gambel oak in southwestern ponderosa pine-oak forests

    Science.gov (United States)

    Scott R. Abella; Peter Z. Fulé

    2008-01-01

    Gambel oak (Quercus gambelii) is ecologically and aesthetically valuable in southwestern ponderosa pine (Pinus ponderosa) forests. Fire effects on Gambel oak are important because fire may be used in pine-oak forests to manage oak directly or to accomplish other management objectives. We used published literature to: (1) ascertain...

  8. Introducing GFWED: The Global Fire Weather Database

    Science.gov (United States)

    Field, R. D.; Spessa, A. C.; Aziz, N. A.; Camia, A.; Cantin, A.; Carr, R.; de Groot, W. J.; Dowdy, A. J.; Flannigan, M. D.; Manomaiphiboon, K.; hide

    2015-01-01

    The Canadian Forest Fire Weather Index (FWI) System is the mostly widely used fire danger rating system in the world. We have developed a global database of daily FWI System calculations, beginning in 1980, called the Global Fire WEather Database (GFWED) gridded to a spatial resolution of 0.5 latitude by 2-3 longitude. Input weather data were obtained from the NASA Modern Era Retrospective-Analysis for Research and Applications (MERRA), and two different estimates of daily precipitation from rain gauges over land. FWI System Drought Code calculations from the gridded data sets were compared to calculations from individual weather station data for a representative set of 48 stations in North, Central and South America, Europe, Russia,Southeast Asia and Australia. Agreement between gridded calculations and the station-based calculations tended to be most different at low latitudes for strictly MERRA based calculations. Strong biases could be seen in either direction: MERRA DC over the Mato Grosso in Brazil reached unrealistically high values exceeding DCD1500 during the dry season but was too low over Southeast Asia during the dry season. These biases are consistent with those previously identified in MERRAs precipitation, and they reinforce the need to consider alternative sources of precipitation data. GFWED can be used for analyzing historical relationships between fire weather and fire activity at continental and global scales, in identifying large-scale atmosphereocean controls on fire weather, and calibration of FWI-based fire prediction models.

  9. Ethnoecology of Fire: An Experimental Approach in the Ohio Valley

    Science.gov (United States)

    Erin B. Hines; Jan Salick; Elaine Kennedy Sutherland; Todd F. Hutchinson; Steve Sutherland; Steve Sutherland

    2000-01-01

    Native Americans used fire to manipulate nature and directly benefit their survival. Certain plant species, many of which were useful to Native Americans as sources of food, fiber, dye, medicine, and game browse, are adapted to survive and even thrive in post-burn environments. Evidence suggests that Native Americans intentionally set fires to encourage growth and...

  10. Costs of fire suppression forces based on cost-aggregation approach

    Science.gov (United States)

    Gonz& aacute; lez-Cab& aacute; Armando n; Charles W. McKetta; Thomas J. Mills

    1984-01-01

    A cost-aggregation approach has been developed for determining the cost of Fire Management Inputs (FMls)-the direct fireline production units (personnel and equipment) used in initial attack and large-fire suppression activities. All components contributing to an FMI are identified, computed, and summed to estimate hourly costs. This approach can be applied to any FMI...

  11. Criteria for classification and reporting of fire incidences in nuclear power plants of India

    International Nuclear Information System (INIS)

    Kapoor, R.K.

    1998-01-01

    Is is important that all fires in and around fire effective neighbourhood of Nuclear Power Plant (NPP) should be promptly reported (Reportable fires) and investigated. However, the depth of investigation and the range of authorities to whom the individual fire incidence need to be reported depends upon the severity of fire. In case of conventional non-chemical industries, the severity of fire depends mainly on the extent of loss caused by fire on property and the burn injury to persons. In case of NPP, two additional losses viz, release of radioactivity to working/public environment and the risk to safety related systems of NPP due to fire assume greater importance. This paper describes the criteria used in NPPs of India for classification of reportable fire incidences into four categories, viz. Insignificant, small, medium and large fires. It also gives the level of investigation depending upon the severity of fire. The fire classification scheme is explained in this paper with the help of worked out examples and two incidences of fire in Indian NPPs. (author)

  12. The footprint of Alaskan tundra fires during the past half-century: implications for surface properties and radiative forcing

    International Nuclear Information System (INIS)

    Rocha, Adrian V; Loranty, Michael M; Higuera, Phil E; Mack, Michelle C; Hu Fengsheng; Jones, Benjamin M; Breen, Amy L; Rastetter, Edward B; Shaver, Gus R; Goetz, Scott J

    2012-01-01

    Recent large and frequent fires above the Alaskan arctic circle have forced a reassessment of the ecological and climatological importance of fire in arctic tundra ecosystems. Here we provide a general overview of the occurrence, distribution, and ecological and climate implications of Alaskan tundra fires over the past half-century using spatially explicit climate, fire, vegetation and remote sensing datasets for Alaska. Our analyses highlight the importance of vegetation biomass and environmental conditions in regulating tundra burning, and demonstrate that most tundra ecosystems are susceptible to burn, providing the environmental conditions are right. Over the past two decades, fire perimeters above the arctic circle have increased in size and importance, especially on the North Slope, indicating that future wildfire projections should account for fire regime changes in these regions. Remote sensing data and a literature review of thaw depths indicate that tundra fires have both positive and negative implications for climatic feedbacks including a decadal increase in albedo radiative forcing immediately after a fire, a stimulation of surface greenness and a persistent long-term (>10 year) increase in thaw depth. In order to address the future impact of tundra fires on climate, a better understanding of the control of tundra fire occurrence as well as the long-term impacts on ecosystem carbon cycling will be required. (letter)

  13. Ash transformation during co-firing coal and straw

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Jensen, Peter Arendt; Jensen, Anker Degn

    2007-01-01

    Co-firing straw with coal in pulverized fuel boilers can cause problems related to fly ash utilization, deposit formation, corrosion and SCR catalyst deactivation due to the high contents of Cl and K in the ash. To investigate the interaction between coal and straw ash and the effect of coal...... quality on fly ash and deposit properties, straw was co-fired with three kinds of coal in an entrained flow reactor. The compositions of the produced ashes were compared to the available literature data to find suitable scaling parameters that can be used to predict the composition of ash from straw...... and coal co-firing. Reasonable agreement in fly ash compositions regarding total K and fraction of water soluble K was obtained between co-firing in an entrained flow reactor and full-scale plants. Capture of potassium and subsequent release of HCl can be achieved by sulphation with SO2 and more...

  14. FEMME- post-Fire Emergency ManageMEnt tool.

    Science.gov (United States)

    Vieira, Diana; Serpa, Dalila; Rocha, João; Nunes, João; Keizer, Jacob

    2017-04-01

    Wildfires can have important impacts on hydrological and soil erosion processes in forest catchments, due to the destruction of vegetation cover and changes to soil properties. The involved processes however, are non-linear and not fully understood. This has severely limited the understanding on the impacts of wildfires, and, as a consequence, current runoff-erosion models are poorly adapted to recently burned forest conditions. Furthermore, while post-fire forestry operations and, to a lesser extent, post-fire soil conservation measures are commonly applied, their hydrological and erosion impacts continue poorly known, hampering decision-making by land owners and managers. Past post-wildfire research in Portugal has involved simple adaptations of plot-scale runoff-erosion models to post-fire conditions. This follow-up study focusses on model adaptation to selected post-fire soil conservation measures. To this end, full stock is taken of various datasets collected by several (past and ongoing research projects. The selected model is the Morgan-Morgan-Finney model (MMF, Morgan,2001), which already proved its suitability for post-fire conditions in Portugal (Vieira et al, 2010, 2014) as well as NW-Spain ( Fernández et al., 2010). The present results concerned runoff and erosion different burn severities and various post-fire mitigation treatments (mulch, hydromulch, needle cast, barriers), focussing on the plot and field scale. The results for both the first and the second year following the wildfire revealed good model efficiency, not only for burned and untreated conditions but also for burned and treated conditions. These results thus reinforced earlier findings that MMF is a suitable model for the envisaged post-fire soil erosion assessment tool, coined "FEMME". The data used for post-fire soil erosion calibration with the MMF already allows the delineation of the post-fire management FEMME tool. Nevertheless, further model assessment will address additional

  15. Optimizing prescribed fire allocation for managing fire risk in central Catalonia.

    Science.gov (United States)

    Alcasena, Fermín J; Ager, Alan A; Salis, Michele; Day, Michelle A; Vega-Garcia, Cristina

    2018-04-15

    We used spatial optimization to allocate and prioritize prescribed fire treatments in the fire-prone Bages County, central Catalonia (northeastern Spain). The goal of this study was to identify suitable strategic locations on forest lands for fuel treatments in order to: 1) disrupt major fire movements, 2) reduce ember emissions, and 3) reduce the likelihood of large fires burning into residential communities. We first modeled fire spread, hazard and exposure metrics under historical extreme fire weather conditions, including node influence grid for surface fire pathways, crown fraction burned and fire transmission to residential structures. Then, we performed an optimization analysis on individual planning areas to identify production possibility frontiers for addressing fire exposure and explore alternative prescribed fire treatment configurations. The results revealed strong trade-offs among different fire exposure metrics, showed treatment mosaics that optimize the allocation of prescribed fire, and identified specific opportunities to achieve multiple objectives. Our methods can contribute to improving the efficiency of prescribed fire treatment investments and wildfire management programs aimed at creating fire resilient ecosystems, facilitating safe and efficient fire suppression, and safeguarding rural communities from catastrophic wildfires. The analysis framework can be used to optimally allocate prescribed fire in other fire-prone areas within the Mediterranean region and elsewhere. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Comparative Evaluation of Five Fire Emissions Datasets Using the GEOS-5 Model

    Science.gov (United States)

    Ichoku, C. M.; Pan, X.; Chin, M.; Bian, H.; Darmenov, A.; Ellison, L.; Kucsera, T. L.; da Silva, A. M., Jr.; Petrenko, M. M.; Wang, J.; Ge, C.; Wiedinmyer, C.

    2017-12-01

    Wildfires and other types of biomass burning affect most vegetated parts of the globe, contributing 40% of the annual global atmospheric loading of carbonaceous aerosols, as well as significant amounts of numerous trace gases, such as carbon dioxide, carbon monoxide, and methane. Many of these smoke constituents affect the air quality and/or the climate system directly or through their interactions with solar radiation and cloud properties. However, fire emissions are poorly constrained in global and regional models, resulting in high levels of uncertainty in understanding their real impacts. With the advent of satellite remote sensing of fires and burned areas in the last couple of decades, a number of fire emissions products have become available for use in relevant research and applications. In this study, we evaluated five global biomass burning emissions datasets, namely: (1) GFEDv3.1 (Global Fire Emissions Database version 3.1); (2) GFEDv4s (Global Fire Emissions Database version 4 with small fires); (3) FEERv1 (Fire Energetics and Emissions Research version 1.0); (4) QFEDv2.4 (Quick Fire Emissions Dataset version 2.4); and (5) Fire INventory from NCAR (FINN) version 1.5. Overall, the spatial patterns of biomass burning emissions from these inventories are similar, although the magnitudes of the emissions can be noticeably different. The inventories derived using top-down approaches (QFEDv2.4 and FEERv1) are larger than those based on bottom-up approaches. For example, global organic carbon (OC) emissions in 2008 are: QFEDv2.4 (51.93 Tg), FEERv1 (28.48 Tg), FINN v1.5 (19.48 Tg), GFEDv3.1 (15.65 Tg) and GFEDv4s (13.76 Tg); representing a factor of 3.7 difference between the largest and the least. We also used all five biomass-burning emissions datasets to conduct aerosol simulations using the NASA Goddard Earth Observing System Model, Version 5 (GEOS-5), and compared the resulting aerosol optical depth (AOD) output to the corresponding retrievals from MODIS

  17. Three-dimensional tracking for efficient fire fighting in complex situations

    Science.gov (United States)

    Akhloufi, Moulay; Rossi, Lucile

    2009-05-01

    Each year, hundred millions hectares of forests burn causing human and economic losses. For efficient fire fighting, the personnel in the ground need tools permitting the prediction of fire front propagation. In this work, we present a new technique for automatically tracking fire spread in three-dimensional space. The proposed approach uses a stereo system to extract a 3D shape from fire images. A new segmentation technique is proposed and permits the extraction of fire regions in complex unstructured scenes. It works in the visible spectrum and combines information extracted from YUV and RGB color spaces. Unlike other techniques, our algorithm does not require previous knowledge about the scene. The resulting fire regions are classified into different homogenous zones using clustering techniques. Contours are then extracted and a feature detection algorithm is used to detect interest points like local maxima and corners. Extracted points from stereo images are then used to compute the 3D shape of the fire front. The resulting data permits to build the fire volume. The final model is used to compute important spatial and temporal fire characteristics like: spread dynamics, local orientation, heading direction, etc. Tests conducted on the ground show the efficiency of the proposed scheme. This scheme is being integrated with a fire spread mathematical model in order to predict and anticipate the fire behaviour during fire fighting. Also of interest to fire-fighters, is the proposed automatic segmentation technique that can be used in early detection of fire in complex scenes.

  18. Validation of the NATO Armaments Ballistic Kernel for use in small-arms fire control systems

    Directory of Open Access Journals (Sweden)

    D. Corriveau

    2017-06-01

    Full Text Available In support for the development of a new small-arm ballistic computer based on the NATO Armaments Ballistic Kernel (NABK for the Canadian snipers, DRDC Valcartier Research Centre was asked to carry out high-fidelity 6 degree-of-freedom (6-DOF trajectory simulations for a set of relevant vignettes for the snipers, and to compare the direct fire 6-DOF simulation results with those obtained with the 4-DOF NATO Armaments Ballistic Kernel (NABK adapted to simulate small-arm ammunition trajectories. To conduct this study, DRDC Valcartier Research Centre used BALCO v1.0b. This paper presents (1 the process and the methodology employed to carry out the sniper direct fire solution study, (2 the modeling and the simulation of the sniper projectile, the approach used in calculating the firing solutions, and the results of direct fire simulations for the sniper vignettes, and (3 an analysis of firing solutions obtained with the BALCO engine versus those of NABK. The work presented in this paper serves to validate the use of NABK for the new sniper ballistic computer.

  19. Enhanced Fire Events Database to Support Fire PRA

    International Nuclear Information System (INIS)

    Baranowsky, Patrick; Canavan, Ken; St. Germain, Shawn

    2010-01-01

    This paper provides a description of the updated and enhanced Fire Events Data Base (FEDB) developed by the Electric Power Research Institute (EPRI) in cooperation with the U.S. Nuclear Regulatory Commission (NRC). The FEDB is the principal source of fire incident operational data for use in fire PRAs. It provides a comprehensive and consolidated source of fire incident information for nuclear power plants operating in the U.S. The database classification scheme identifies important attributes of fire incidents to characterize their nature, causal factors, and severity consistent with available data. The database provides sufficient detail to delineate important plant specific attributes of the incidents to the extent practical. A significant enhancement to the updated FEDB is the reorganization and refinement of the database structure and data fields and fire characterization details added to more rigorously capture the nature and magnitude of the fire and damage to the ignition source and nearby equipment and structures.

  20. Fire impacts on European Boreal soils: A review

    Science.gov (United States)

    Pereira, Paulo; Oliva, Marc; Cerda, Artemi

    2016-04-01

    Fire is an important natural disturbance in boreal ecosystems, fundamental to understand plant distribution (Ryan, 2002; Wallenius et al., 2004; Granstrom, 2001). Nevertheless, nowadays the intense and successful, fire suppression measures are changing their ecological role (Pereira et al., 2013a,b). This is consequence of the lack of understanding of stakeholders and decision makers about the role of the fire in the ecosystems (Mierasukas and Pereira, 2013; Pereira et al., 2016). This fire suppression measures are increasing the amount of fuel accumulation and the risk of severe wildfires, which can increase of frequency and severity in a context of climate change. Fire is a good tool for landscape management and restoration of degraded ecosystems (Toivanen and Kotiaho, 2007). Fire is considered a soil forming factor (Certini, 2014) and in boreal environments it has been observed that low fire severities, do not change importantly soil properties, mean fire severities induce positive impacts on soil, since add an important amounts of nutrients into soil profile and high severity fires had negative impacts due to the high consumption of organic matter (Vanha-Majamaa et al., 2007; Pereira et al., 2014). References Certini, G., 2014. Fire as a soil-forming factor. Ambio, 43, 191-195 Granstrom A. 2001. Fire management for biodiversity in the European Boreal forest. Scandinavian Journal of Forest Research 3: 62-69. Mierauskas, P., Pereira, P. (2013) Stakeholders perception about prescribed fire use in Lithuania. First results, Flamma, 4(3), 157-161. Pereira, P., Cerdà, A., Jordán, A., Bolutiene, V., Úbeda, X., Pranskevicius, M., Mataix-Solera, J. (2013) Spatio-temporal vegetation recuperation after a grassland fire in Lithuania, Procedia Environmental Sciences, 19:856-864 Pereira, P., Mierauskas, P., Ubeda, X., Mataix-Solera, J.,Cerda, A. (2012) Fire in protected areas - the effect of the protection and importance of fire management, Environmental Research

  1. Fire Behavior (FB)

    Science.gov (United States)

    Robert E. Keane

    2006-01-01

    The Fire Behavior (FB) method is used to describe the behavior of the fire and the ambient weather and fuel conditions that influence the fire behavior. Fire behavior methods are not plot based and are collected by fire event and time-date. In general, the fire behavior data are used to interpret the fire effects documented in the plot-level sampling. Unlike the other...

  2. Metal fires and their implications for advanced reactors.

    Energy Technology Data Exchange (ETDEWEB)

    Nowlen, Steven Patrick; Figueroa, Victor G.; Olivier, Tara Jean; Hewson, John C.; Blanchat, Thomas K.

    2010-10-01

    This report details the primary results of the Laboratory Directed Research and Development project (LDRD 08-0857) Metal Fires and Their Implications for Advance Reactors. Advanced reactors may employ liquid metal coolants, typically sodium, because of their many desirable qualities. This project addressed some of the significant challenges associated with the use of liquid metal coolants, primary among these being the extremely rapid oxidation (combustion) that occurs at the high operating temperatures in reactors. The project has identified a number of areas for which gaps existed in knowledge pertinent to reactor safety analyses. Experimental and analysis capabilities were developed in these areas to varying degrees. In conjunction with team participation in a DOE gap analysis panel, focus was on the oxidation of spilled sodium on thermally massive surfaces. These are spills onto surfaces that substantially cool the sodium during the oxidation process, and they are relevant because standard risk mitigation procedures seek to move spill environments into this regime through rapid draining of spilled sodium. While the spilled sodium is not quenched, the burning mode is different in that there is a transition to a smoldering mode that has not been comprehensively described previously. Prior work has described spilled sodium as a pool fire, but there is a crucial, experimentally-observed transition to a smoldering mode of oxidation. A series of experimental measurements have comprehensively described the thermal evolution of this type of sodium fire for the first time. A new physics-based model has been developed that also predicts the thermal evolution of this type of sodium fire for the first time. The model introduces smoldering oxidation through porous oxide layers to go beyond traditional pool fire analyses that have been carried out previously in order to predict experimentally observed trends. Combined, these developments add significantly to the safety

  3. Development at the wildland-urban interface and the mitigation of forest-fire risk.

    Science.gov (United States)

    Spyratos, Vassilis; Bourgeron, Patrick S; Ghil, Michael

    2007-09-04

    This work addresses the impacts of development at the wildland-urban interface on forest fires that spread to human habitats. Catastrophic fires in the western United States and elsewhere make these impacts a matter of urgency for decision makers, scientists, and the general public. Using a simple fire-spread model, along with housing and vegetation data, we show that fire size probability distributions can be strongly modified by the density and flammability of houses. We highlight a sharp transition zone in the parameter space of vegetation flammability and house density. Many actual fire landscapes in the United States appear to have spreading properties close to this transition. Thus, the density and flammability of buildings should be taken into account when assessing fire risk at the wildland-urban interface. Moreover, our results highlight ways for regulation at this interface to help mitigate fire risk.

  4. Pattern formation and firing synchronization in networks of map neurons

    International Nuclear Information System (INIS)

    Wang Qingyun; Duan Zhisheng; Huang Lin; Chen Guanrong; Lu Qishao

    2007-01-01

    Patterns and collective phenomena such as firing synchronization are studied in networks of nonhomogeneous oscillatory neurons and mixtures of oscillatory and excitable neurons, with dynamics of each neuron described by a two-dimensional (2D) Rulkov map neuron. It is shown that as the coupling strength is increased, typical patterns emerge spatially, which propagate through the networks in the form of beautiful target waves or parallel ones depending on the size of networks. Furthermore, we investigate the transitions of firing synchronization characterized by the rate of firing when the coupling strength is increased. It is found that there exists an intermediate coupling strength; firing synchronization is minimal simultaneously irrespective of the size of networks. For further increasing the coupling strength, synchronization is enhanced. Since noise is inevitable in real neurons, we also investigate the effects of white noise on firing synchronization for different networks. For the networks of oscillatory neurons, it is shown that firing synchronization decreases when the noise level increases. For the missed networks, firing synchronization is robust under the noise conditions considered in this paper. Results presented in this paper should prove to be valuable for understanding the properties of collective dynamics in real neuronal networks

  5. Study of the Thermal Properties and the Fire Performance of Flame Retardant-Organic PCM in Bulk Form

    Directory of Open Access Journals (Sweden)

    Anabel Palacios

    2018-01-01

    Full Text Available The implementation of organic phase change materials (PCMs in several applications such as heating and cooling or building comfort is an important target in thermal energy storage (TES. However, one of the major drawbacks of organic PCMs implementation is flammability. The addition of flame retardants to PCMs or shape-stabilized PCMs is one of the approaches to address this problem and improve their final deployment in the building material sector. In this study, the most common organic PCM, Paraffin RT-21, and fatty acids mixtures of capric acid (CA, myristic acid (MA, and palmitic acid (PA in bulk, were tested to improve their fire reaction. Several flame retardants, such as ammonium phosphate, melamine phosphate, hydromagnesite, magnesium hydroxide, and aluminum hydroxide, were tested. The properties of the improved PCM with flame retardants were characterized by thermogravimetric analyses (TGA, the dripping test, and differential scanning calorimetry (DSC. The results for the dripping test show that fire retardancy was considerably enhanced by the addition of hydromagnesite (50 wt % and magnesium hydroxide (50 wt % in fatty acids mixtures. This will help the final implementation of these enhanced PCMs in building sector. The influence of the addition of flame retardants on the melting enthalpy and temperatures of PCMs has been evaluated.

  6. Study of the Thermal Properties and the Fire Performance of Flame Retardant-Organic PCM in Bulk Form

    Science.gov (United States)

    Palacios, Anabel; De Gracia, Alvaro

    2018-01-01

    The implementation of organic phase change materials (PCMs) in several applications such as heating and cooling or building comfort is an important target in thermal energy storage (TES). However, one of the major drawbacks of organic PCMs implementation is flammability. The addition of flame retardants to PCMs or shape-stabilized PCMs is one of the approaches to address this problem and improve their final deployment in the building material sector. In this study, the most common organic PCM, Paraffin RT-21, and fatty acids mixtures of capric acid (CA), myristic acid (MA), and palmitic acid (PA) in bulk, were tested to improve their fire reaction. Several flame retardants, such as ammonium phosphate, melamine phosphate, hydromagnesite, magnesium hydroxide, and aluminum hydroxide, were tested. The properties of the improved PCM with flame retardants were characterized by thermogravimetric analyses (TGA), the dripping test, and differential scanning calorimetry (DSC). The results for the dripping test show that fire retardancy was considerably enhanced by the addition of hydromagnesite (50 wt %) and magnesium hydroxide (50 wt %) in fatty acids mixtures. This will help the final implementation of these enhanced PCMs in building sector. The influence of the addition of flame retardants on the melting enthalpy and temperatures of PCMs has been evaluated. PMID:29329212

  7. Study of the Thermal Properties and the Fire Performance of Flame Retardant-Organic PCM in Bulk Form.

    Science.gov (United States)

    Palacios, Anabel; De Gracia, Alvaro; Haurie, Laia; Cabeza, Luisa F; Fernández, A Inés; Barreneche, Camila

    2018-01-12

    The implementation of organic phase change materials (PCMs) in several applications such as heating and cooling or building comfort is an important target in thermal energy storage (TES). However, one of the major drawbacks of organic PCMs implementation is flammability. The addition of flame retardants to PCMs or shape-stabilized PCMs is one of the approaches to address this problem and improve their final deployment in the building material sector. In this study, the most common organic PCM, Paraffin RT-21, and fatty acids mixtures of capric acid (CA), myristic acid (MA), and palmitic acid (PA) in bulk, were tested to improve their fire reaction. Several flame retardants, such as ammonium phosphate, melamine phosphate, hydromagnesite, magnesium hydroxide, and aluminum hydroxide, were tested. The properties of the improved PCM with flame retardants were characterized by thermogravimetric analyses (TGA), the dripping test, and differential scanning calorimetry (DSC). The results for the dripping test show that fire retardancy was considerably enhanced by the addition of hydromagnesite (50 wt %) and magnesium hydroxide (50 wt %) in fatty acids mixtures. This will help the final implementation of these enhanced PCMs in building sector. The influence of the addition of flame retardants on the melting enthalpy and temperatures of PCMs has been evaluated.

  8. Mechanical properties and fire retardancy of bidirectional reinforced composite based on biodegradable starch resin and basalt fibres

    Directory of Open Access Journals (Sweden)

    2008-11-01

    Full Text Available Environmental problems caused by extensive use of polymeric materials arise mainly due to lack of landfill space and depletion of finite natural resources of fossil raw materials, such as petroleum or natural gas. The substitution of synthetic petroleum-based resins with natural biodegradable resins appears to be one appropriate measure to remedy the above-mentioned situation. This study presents the development of a composite that uses environmentally degradable starch-based resin as matrix and basalt fibre plain fabric as reinforcement. Prepreg sheets were manufactured by means of a modified doctor blade system and a hot power press. The sheets were used to manufacture bidirectional-reinforced specimens with fibre volume contents ranging from 33 to 61%. Specimens were tested for tensile and flexural strength, and exhibited values of up to 373 and 122 MPa, respectively. Through application of silane coupling agents to the reinforcement fibres, the flexural composite properties were subsequently improved by as much as 38%. Finally, in order to enhance the fire retardancy and hence the applicability of the composite, fire retardants were applied to the resin, and their effectiveness was tested by means of flame rating (according to UL 94 and thermogravimetric analysis (TGA, respectively.

  9. Modification of poly(styrene-block-butadiene-block-styrene) [SBS] with phosphorus containing fire retardants

    DEFF Research Database (Denmark)

    Chernyy, Sergey; Ullah, Saif; Jomaas, Grunde

    2015-01-01

    An elaborate survey of the chemical modification methods for endowing highly flammable SBS with increased fire resistant properties by means of chemical modification of the polymer backbone with phosphorus containing fire retardant species is presented. Optimal conditions for free radical addition...

  10. A study on fire design accidental loads for aluminum safety helidecks

    Directory of Open Access Journals (Sweden)

    Sang Jin Kim

    2016-11-01

    Full Text Available The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

  11. Study on aging management of fire protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Fang Huasong; Du Yu; Li Jianwen; Shi Haining; Tu Fengsheng

    2010-01-01

    Fire prevention, fire fighting and fire automatic alarms are three aspects which be included in fire protection system in nuclear power plants. The fire protection system can protect personnel, equipment etc in the fire, so their performance will have a direct influence on the safe operation in nuclear power plants. The disabled accidents caused by aging have happened continuously with the extension of time in the fire protection system, which is the major security risk during the running time in nuclear power plants. In view of the importance of fire protection system and the severity of aging problems, the aging are highly valued by the plant operators and related organizations. Though the feedback of operating experience in nuclear power plant, the impact of the fire-fighting equipment aging on system performance and reliability be assessed, the aging sensitive equipment be selected to carry out the aging analysis and to guide the management and maintenance to guarantee the healthy operation in life time of fire protection system in nuclear power plant. (authors)

  12. The effect of fire on spatial separation between wolves and caribou

    Directory of Open Access Journals (Sweden)

    Hugh S. Robinson

    2012-03-01

    Full Text Available Fire management is an important conservation tool in Canada’s national parks. Fires can benefit some species, while others may be negatively impacted. We used GPS and VHF collar data for 47 wolves from 12 separate packs and 153 caribou from 5 separate herds, and resource selection analysis to model the effects of fire on these species’ habitat and potential interactions. Resource selection modeling showed that wolves select for burned areas and areas close to burns, presumably due to the presence of primary prey (i.e., elk and moose, while caribou avoid burns. Fire reduced the amount of high quality caribou habitat (a direct effect, but also increased the probability of wolf-caribou overlap (an indirect effect. We delineated a spatial index of caribou “safe zones” (areas of low overlap with wolves, and found a positive relationship between the proportion of a herd’s home range represented by “safe zone” in winter and population size (P = 0.10, n=4. While currently-planned prescribed fires in Banff and Jasper reduced the amount of quality caribou habitat by up to 4%, they reduced the area of “safe zones” by up to 7%, varying by herd, location, and season. We suggest that conservation managers should account for the indirect, predator-mediated impacts of fire on caribou in addition to direct effects of habitat loss.

  13. Structure and phylogenetic diversity of post-fire ectomycorrhizal communities of maritime pine.

    Science.gov (United States)

    Rincón, A; Santamaría, B P; Ocaña, L; Verdú, M

    2014-02-01

    Environmental disturbances define the diversity and assemblage of species, affecting the functioning of ecosystems. Fire is a major disturbance of Mediterranean pine forests. Pines are highly dependent on the ectomycorrhizal (EM) fungal symbiosis, which is critical for tree recruitment under primary succession. To determine the effects of time since fire on the structure and recovery of EM fungal communities, we surveyed the young Pinus pinaster regenerate in three sites differing in the elapsed time after the last fire event. Pine roots were collected, and EM fungi characterized by sequencing the internal transcribed spacer (ITS) and the large subunit (LSU) regions of the nuclear ribosomal (nr)-DNA. The effects of the elapsed time after fire on the EM community structure (richness, presence/absence of fungi, phylogenetic diversity) and on soil properties were analysed.Fungal richness decreased with the elapsed time since the fire; although, the phylogenetic diversity of the EM community increased. Soil properties were different depending on the elapsed time after fire and particularly, the organic matter, carbon-to-nitrogen (C/N) ratio, nitrogen and iron significantly correlated with the assemblage of fungal species. Ascomycetes, particularly Tuberaceae and Pezizales, were significantly over-represented on saplings in the burned site. On seedlings, a significant over-representation of Rhizopogonaceae and Atheliaceae was observed in the most recently burned site, while other fungi (i.e. Cortinariaceae) were significantly under-represented. Our results are consistent with the hypothesis that fire can act as a selective agent by printing a phylogenetic signal on the EM fungal communities associated with naturally regenerated pines, pointing out to some groups as potential fire-adapted fungi.

  14. Detection and Characterization of Low Temperature Peat Fires during the 2015 Fire Catastrophe in Indonesia Using a New High-Sensitivity Fire Monitoring Satellite Sensor (FireBird).

    Science.gov (United States)

    Atwood, Elizabeth C; Englhart, Sandra; Lorenz, Eckehard; Halle, Winfried; Wiedemann, Werner; Siegert, Florian

    2016-01-01

    Vast and disastrous fires occurred on Borneo during the 2015 dry season, pushing Indonesia into the top five carbon emitting countries. The region was affected by a very strong El Niño-Southern Oscillation (ENSO) climate phenomenon, on par with the last severe event in 1997/98. Fire dynamics in Central Kalimantan were investigated using an innovative sensor offering higher sensitivity to a wider range of fire intensities at a finer spatial resolution (160 m) than heretofore available. The sensor is onboard the TET-1 satellite, part of the German Aerospace Center (DLR) FireBird mission. TET-1 images (acquired every 2-3 days) from the middle infrared were used to detect fires continuously burning for almost three weeks in the protected peatlands of Sebangau National Park as well as surrounding areas with active logging and oil palm concessions. TET-1 detection capabilities were compared with MODIS active fire detection and Landsat burned area algorithms. Fire dynamics, including fire front propagation speed and area burned, were investigated. We show that TET-1 has improved detection capabilities over MODIS in monitoring low-intensity peatland fire fronts through thick smoke and haze. Analysis of fire dynamics revealed that the largest burned areas resulted from fire front lines started from multiple locations, and the highest propagation speeds were in excess of 500 m/day (all over peat > 2m deep). Fires were found to occur most often in concessions that contained drainage infrastructure but were not cleared prior to the fire season. Benefits of implementing this sensor system to improve current fire management techniques are discussed. Near real-time fire detection together with enhanced fire behavior monitoring capabilities would not only improve firefighting efforts, but also benefit analysis of fire impact on tropical peatlands, greenhouse gas emission estimations as well as mitigation measures to reduce severe fire events in the future.

  15. Dynamical mechanisms for sensitive response of aperiodic firing cells to external stimulation

    International Nuclear Information System (INIS)

    Xie Yong; Xu Jianxue; Hu Sanjue; Kang Yanmei; Yang Hongjun; Duan Yubin

    2004-01-01

    An interesting phenomenon that aperiodic firing neurons have a higher sensitivity to drugs than periodic firing neurons have been reported for the chronically compressed dorsal root ganglion neurons in rats. In this study, the dynamical mechanisms for such a phenomenon are uncovered from the viewpoint of dynamical systems theory. We use the Rose-Hindmarsh neuron model to illustrate our opinions. Periodic orbit theory is introduced to characterize the dynamical behavior of aperiodic firing neurons. It is considered that bifurcations, crises and sensitive dependence of chaotic motions on control parameters can be the underlying mechanisms. And then, a similar analysis is applied to the modified Chay model describing the firing behavior of pancreatic beta cells. The same dynamical mechanisms can be obtained underlying that aperiodic firing cells are more sensitive to external stimulation than periodic firing ones. As a result, we conjecture that sensitive response of aperiodic firing cells to external stimulation is a universal property of excitable cells

  16. Study on evaluation of containment capability of glove box under fire accident (2)

    International Nuclear Information System (INIS)

    Abe, Hitoshi; Watanabe, Koji; Tashiro, Shinsuke; Uchiyama, Gunzo

    2007-11-01

    In the MOX fuel fabrication facility, MOX is required to be handled in glove box to sustain containment of MOX into the facility. In case of fire in the facility, the containment capability of glove box may be deteriorated by pyrolysis or combustion of the plastic materials as components of glove box caused by thermal stress from flame. The purpose of this study is to examine pyrolysis and combustion properties of the materials for applying them to quantitative evaluation method for the containment capability of glove box under fire. This report summarize experimental results about the properties under the air condition and investigation of evaluation model for estimating time-course of deteriorating containment capability of glove box under fire. (author)

  17. FDS Modeling of the Sensitivity of the Smoke Potential Values used in Fire Safety Strategies

    DEFF Research Database (Denmark)

    Corches, Andrei-Mircea; Ulriksen, Lene; Jomaas, Grunde

    2014-01-01

    To investigate the sensitivity of Fire Dynamics Simulator (FDS) with respect to the input parameters that are used to define the optical properties of the smoke, a parametric study was performed for relevant fire scenarios in an open plan office building. The parametric study mainly focuses on th...... to defining the design fires will reduce the sensitivity of the numerical fire simulation and further reduce the risk of overestimating the evacuation safety level (ESL) of the building....

  18. Coal Field Fire Fighting - Practiced methods, strategies and tactics

    Science.gov (United States)

    Wündrich, T.; Korten, A. A.; Barth, U. H.

    2009-04-01

    Subsurface coal fires destroy millions of tons of coal each year, have an immense impact to the ecological surrounding and threaten further coal reservoirs. Due to enormous dimensions a coal seam fire can develop, high operational expenses are needed. As part of the Sino-German coal fire research initiative "Innovative technologies for exploration, extinction and monitoring of coal fires in Northern China" the research team of University of Wuppertal (BUW) focuses on fire extinction strategies and tactics as well as aspects of environmental and health safety. Besides the choice and the correct application of different extinction techniques further factors are essential for the successful extinction. Appropriate tactics, well trained and protected personnel and the choice of the best fitting extinguishing agents are necessary for the successful extinction of a coal seam fire. The chosen strategy for an extinction campaign is generally determined by urgency and importance. It may depend on national objectives and concepts of coal conservation, on environmental protection (e.g. commitment to green house gases (GHG) reductions), national funding and resources for fire fighting (e.g. personnel, infrastructure, vehicles, water pipelines); and computer-aided models and simulations of coal fire development from self ignition to extinction. In order to devise an optimal fire fighting strategy, "aims of protection" have to be defined in a first step. These may be: - directly affected coal seams; - neighboring seams and coalfields; - GHG emissions into the atmosphere; - Returns on investments (costs of fire fighting compared to value of saved coal). In a further step, it is imperative to decide whether the budget shall define the results, or the results define the budget; i.e. whether there are fixed objectives for the mission that will dictate the overall budget, or whether the limited resources available shall set the scope within which the best possible results shall be

  19. Fire-driven alien invasion in a fire-adapted ecosystem

    Science.gov (United States)

    Keeley, Jon E.; Brennan, Teresa J.

    2012-01-01

    Disturbance plays a key role in many alien plant invasions. However, often the main driver of invasion is not disturbance per se but alterations in the disturbance regime. In some fire-adapted shrublands, the community is highly resilient to infrequent, high-intensity fires, but changes in the fire regime that result in shorter fire intervals may make these communities more susceptible to alien plant invasions. This study examines several wildfire events that resulted in short fire intervals in California chaparral shrublands. In one study, we compared postfire recovery patterns in sites with different prefire stand ages (3 and 24 years), and in another study we compared sites that had burned once in four years with sites that had burned twice in this period. The population size of the dominant native shrub Adenostoma fasciculatum was drastically reduced following fire in the 3-year sites relative to the 24-year sites. The 3-year sites had much greater alien plant cover and significantly lower plant diversity than the 24-year sites. In a separate study, repeat fires four years apart on the same sites showed that annual species increased significantly after the second fire, and alien annuals far outnumbered native annuals. Aliens included both annual grasses and annual forbs and were negatively correlated with woody plant cover. Native woody species regenerated well after the first fire but declined after the second fire, and one obligate seeding shrub was extirpated from two sites by the repeat fires. It is concluded that some fire-adapted shrublands are vulnerable to changes in fire regime, and this can lead to a loss of native diversity and put the community on a trajectory towards type conversion from a woody to an herbaceous system. Such changes result in alterations in the proportion of natives to non-natives, changes in functional types from deeply rooted shrubs to shallow rooted grasses and forbs, increased fire frequency due to the increase in fine fuels

  20. Fire-driven alien invasion in a fire-adapted ecosystem.

    Science.gov (United States)

    Keeley, Jon E; Brennan, Teresa J

    2012-08-01

    Disturbance plays a key role in many alien plant invasions. However, often the main driver of invasion is not disturbance per se but alterations in the disturbance regime. In some fire-adapted shrublands, the community is highly resilient to infrequent, high-intensity fires, but changes in the fire regime that result in shorter fire intervals may make these communities more susceptible to alien plant invasions. This study examines several wildfire events that resulted in short fire intervals in California chaparral shrublands. In one study, we compared postfire recovery patterns in sites with different prefire stand ages (3 and 24 years), and in another study we compared sites that had burned once in four years with sites that had burned twice in this period. The population size of the dominant native shrub Adenostoma fasciculatum was drastically reduced following fire in the 3-year sites relative to the 24-year sites. The 3-year sites had much greater alien plant cover and significantly lower plant diversity than the 24-year sites. In a separate study, repeat fires four years apart on the same sites showed that annual species increased significantly after the second fire, and alien annuals far outnumbered native annuals. Aliens included both annual grasses and annual forbs and were negatively correlated with woody plant cover. Native woody species regenerated well after the first fire but declined after the second fire, and one obligate seeding shrub was extirpated from two sites by the repeat fires. It is concluded that some fire-adapted shrublands are vulnerable to changes in fire regime, and this can lead to a loss of native diversity and put the community on a trajectory towards type conversion from a woody to an herbaceous system. Such changes result in alterations in the proportion of natives to non-natives, changes in functional types from deeply rooted shrubs to shallow rooted grasses and forbs, increased fire frequency due to the increase in fine fuels

  1. Active and passive fire protection system in academic building KH. Mas Mansur, Islamic University of Indonesia

    Directory of Open Access Journals (Sweden)

    Suryoputro M. Ragil

    2018-01-01

    Full Text Available According to the theory of fire triangle, the existence of combustible materials, heat, and oxygen can cause fire disaster. KH. Mas Mansur building, Islamic University of Indonesia has a fire protection, but rarely to be checked regularly and the number of equipment is less standard as well as the lack of an evacuation route map to facilitate the evacuation process. Inside the building also does not provide safety signs such as the evacuation directions, exit, and warning in case of fire. Therefore, researchers analysed the infrastructure of prevention and control in the building KH. Mas Mansur. Researchers used the method of observation, interviews, and checklist to know the condition directly, and compare with the standard regulations. Results concordance rate of existing infrastructure is 67% fire extinguisher, hydrant box 56%, 71% alarms, sprinkler 0%, 40% detectors, emergency doors 71%, 50% emergency stairs, assembly point 0% and directions 0%. The current results were below the standard of at least 80%. As for recommendations, researchers create a new evacuation map then put the existing infrastructure according to standard regulations, and it had consulted with the specialist of Occupational Safety and Health in the field of fire.

  2. Quantification of regional radiative impacts and climate effects of tropical fire aerosols

    Science.gov (United States)

    Tosca, M. G.; Zender, C. S.; Randerson, J. T.

    2011-12-01

    Regionally expansive smoke clouds originating from deforestation fires in Indonesia can modify local precipitation patterns via direct aerosol scattering and absorption of solar radiation (Tosca et al., 2010). Here we quantify the regional climate impacts of fire aerosols for three tropical burning regions that together account for about 70% of global annual fire emissions. We use the Community Atmosphere Model, version 5 (CAM5) coupled to a slab ocean model (SOM) embedded within the Community Earth System Model (CESM). In addition to direct aerosol radiative effects, CAM5 also quantifies indirect, semi-direct and cloud microphysical aerosol effects. Climate impacts are determined using regionally adjusted emissions data that produce realistic aerosol optical depths in CAM5. We first analyzed a single 12-year transient simulation (1996-2007) forced with unadjusted emissions estimates from the Global Fire Emissions Database, version 3 (GFEDv3) and compared the resulting aerosol optical depths (AODs) for 4 different burning regions (equatorial Asia, southern Africa, South America and boreal North America) to observed MISR and MODIS AODs for the same period. Based on this analysis we adjusted emissions for each burning region between 150 and 300% and forced a second simulation with the regionally adjusted emissions. Improved AODs from this simulation are compared to AERONET observations available at 15 stations throughout the tropics. We present here two transient simulations--one with the adjusted fire emissions and one without fires--to quantify the cumulative fire aerosol climate impact for three major tropical burning regions (equatorial Asia, southern Africa and South America). Specifically, we quantify smoke effects on radiation, precipitation, and temperature. References Tosca, M.G., J.T. Randerson, C.S. Zender, M.G. Flanner and P.J. Rasch (2010), Do biomass burning aerosols intensify drought in equatorial Asia during El Nino?, Atmos. Chem. Phys., 10, 3515

  3. Effects of fire and three fire-fighting chemicals on main soil properties, plant nutrient content and vegetation growth and cover after 10 years

    International Nuclear Information System (INIS)

    Fernández-Fernández, M.; Gómez-Rey, M.X.; González-Prieto, S.J.

    2015-01-01

    The study addresses a knowledge-gap in the long-term ecological consequences of fire and fire-fighting chemicals. Ten years after a prescribed fire and the application of three fire-fighting chemicals, their effects on the soil–plant system were evaluated. Five treatments were established: unburnt soils (US) and burnt soils treated with water alone (BS), foaming agent (BS + Fo), Firesorb (BS + Fi) and ammonium polyphosphate (BS + Ap). Soils (0–2 cm depth) and foliar material of shrubs (Erica umbellata, Pterospartum tridentatum and Ulex micranthus) and trees (Pinus pinaster) were analysed for total N, δ 15 N, and soil-available and plant total macronutrients and trace elements. Soil pH, NH 4 + –N and NO 3 − –N; pine basal diameter and height; and shrub cover and height were also measured. Compared with US plots, burnt soils had less nitrates and more Mo. Although differences were not always significant, BS + Ap had the highest levels of soil available P, Na and Al. Plants from BS + Ap plots had higher values of δ 15 N (P. pinaster and E. umbellata), P (all species), Na (P. tridentatum and U. micranthus) and Mg (E. umbellata and P. tridentatum) than other treatments; while K in plants from BS + Ap plots was the highest among treatments for P. pinaster and the lowest for the shrubs. Pines in US plots were higher and wider than in burnt treatments, except for BS + Ap, where the tallest and widest trees were found, although half of them were either dead (the second highest mortality after BS + Fi) or had a distorted trunk. BS + Ap was the treatment with strongest effects on plants, showing E. umbellata the lowest coverage and height, P. tridentatum the highest coverage, U. micranthus one of the lowest coverages and being the only treatment where Genista triacanthos was absent. Consequently, it is concluded that both fire and ammonium polyphosphate application had significant effects on the soil–plant system after 10 years. - Highlights: • We hypothesized

  4. Passive fire building protection system evaluation (case study: millennium ict centre)

    Science.gov (United States)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  5. Estimating Landscape Fire Particulate Matter (PM) Emissions over Southern Africa using MSG-SEVIRI Fire Radiative Power (FRP) and MODIS Aerosol Optical Thickness Observations

    Science.gov (United States)

    Mota, Bernardo; Wooster, Martin J.

    2016-04-01

    The approach to estimating landscape fire fuel consumption based on the remotely sensed fire radiative power (FRP) thermal energy release rate, as opposed to burned area, is now relatively widely used in studies of fire emissions, including operationally within the Copernicus Atmosphere Monitoring Service (CAMS). Nevertheless, there are still limitations to the approach, including uncertainties associated with using only the few daily overpasses typically provided by polar orbiting satellite systems, the conversion between FRP and smoke emissions, and the increased likelihood that the more frequent data from geostationary systems fails to detect the (probably highly numerous) smaller (i.e. low FRP) component of a regions fire regime. In this study, we address these limitations to directly estimate fire emissions of Particular Matter (PM; or smoke aerosols) by presenting an approach combining the "bottom-up" FRP observations available every 15 minutes across Africa from the Meteosat Spinning Enhanced Visible and Infrared Imager (SEVIRI) Fire Radiative Product (FRP) processed at the EUMETSAT LSA SAF, and the "top-down" aerosol optical thickness (AOT) measures of the fire plumes themselves as measured by the Moderate-resolution Imaging Spectro-radiometer (MODIS) sensors aboard the Terra (MOD04_L2) and Aqua (MYD04_L2) satellites. We determine PM emission coefficients that relate directly to FRP measures by combining these two datasets, and the use of the almost continuous geostationary FRP observations allows us to do this without recourse to (uncertain) data on wind speed at the (unknown) height of the matching plume. We also develop compensation factors to address the detection limitations of small/low intensity (low FRP) fires, and remove the need to estimate fuel consumption by going directly from FRP to PM emissions. We derive the smoke PM emissions coefficients per land cover class by comparing the total fire radiative energy (FRE) released from individual fires

  6. Toxic and fire hazard of flooring

    Directory of Open Access Journals (Sweden)

    Illarionova L. V.

    2017-12-01

    Full Text Available polymer materials have become widespread in the modern construction industry due to their cheapness and variety. With regard to their popularity at the present time there can appear the issues of their toxic and fire danger. The work has studied the samples of two floor synthetic building materials. The results of the determination of the fire hazard indicators of materials (combustibility, flammability, smoke ratio showed their compliance with the current certificates. The authors have studied the properties of gaseous combustion products of samples by the method of thermal analysis and FTIR analysis. The results of chloride ions analysis according the formula of Maxwell-Mohr in thermolysis products indicate the toxicity of the materials studied.

  7. Post-fire vegetation and fuel development influences fire severity patterns in reburns.

    Science.gov (United States)

    Coppoletta, Michelle; Merriam, Kyle E; Collins, Brandon M

    2016-04-01

    In areas where fire regimes and forest structure have been dramatically altered, there is increasing concern that contemporary fires have the potential to set forests on a positive feedback trajectory with successive reburns, one in which extensive stand-replacing fire could promote more stand-replacing fire. Our study utilized an extensive set of field plots established following four fires that occurred between 2000 and 2010 in the northern Sierra Nevada, California, USA that were subsequently reburned in 2012. The information obtained from these field plots allowed for a unique set of analyses investigating the effect of vegetation, fuels, topography, fire weather, and forest management on reburn severity. We also examined the influence of initial fire severity and time since initial fire on influential predictors of reburn severity. Our results suggest that high- to moderate-severity fire in the initial fires led to an increase in standing snags and shrub vegetation, which in combination with severe fire weather promoted high-severity fire effects in the subsequent reburn. Although fire behavior is largely driven by weather, our study demonstrates that post-fire vegetation composition and structure are also important drivers of reburn severity. In the face of changing climatic regimes and increases in extreme fire weather, these results may provide managers with options to create more fire-resilient ecosystems. In areas where frequent high-severity fire is undesirable, management activities such as thinning, prescribed fire, or managed wildland fire can be used to moderate fire behavior not only prior to initial fires, but also before subsequent reburns.

  8. Human impacts on 20th century fire dynamics and implications for global carbon and water trajectories

    Science.gov (United States)

    Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben

    2018-03-01

    Fire is a fundamental Earth system process and the primary ecosystem disturbance on the global scale. It affects carbon and water cycles through changing terrestrial ecosystems, and at the same time, is regulated by weather and climate, vegetation characteristics, and, importantly, human ignitions and suppression (i.e., the direct human effect on fire). Here, we utilize the Community Land Model version 4.5 (CLM4.5) to quantify the impacts of changes in human ignition and suppression on fire dynamics and associated carbon and water cycles. We find that the impact is to significantly reduce the 20th century global burned area by a century average of 38 Mha/yr and by 103 Mha/yr at the end of the century. Land carbon gain is weakened by 17% over the 20th century, mainly due to increased human deforestation fires and associated escape fires (i.e., degradation fires) in the tropical humid forests, even though the decrease in burned area in many other regions due to human fire suppression acts to increase land carbon gain. The direct human effect on fire weakens the upward trend in global runoff throughout the century by 6% and enhances the upward trend in global evapotranspiration since 1945 by 7%. In addition, the above impacts in densely populated, highly developed (if population density > 0.1 person/km2), or moderately populated and developed regions are of opposite sign to those in other regions. Our study suggests that particular attention should be paid to human deforestation and degradation fires in the tropical humid forests when reconstructing and projecting fire carbon emissions and net atmosphere-land carbon exchange and estimating resultant impacts of direct human effect on fire.

  9. Human impacts on 20th century fire dynamics and implications for global carbon and water trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben

    2018-03-01

    Fire is a fundamental Earth system process and the primary ecosystem disturbance on the global scale. It affects carbon and water cycles through changing terrestrial ecosystems, and at the same time, is regulated by weather and climate, vegetation characteristics, and, importantly, human ignitions and suppression (i.e., the direct human effect on fire). Here, we utilize the Community Land Model version 4.5 (CLM4.5) to quantify the impacts of changes in human ignition and suppression on fire dynamics and associated carbon and water cycles. We find that the impact is to significantly reduce the 20th century global burned area by a century average of 38 Mha/yr and by 103 Mha/yr at the end of the century. Land carbon gain is weakened by 17% over the 20th century, mainly due to increased human deforestation fires and associated escape fires (i.e., degradation fires) in the tropical humid forests, even though the decrease in burned area in many other regions due to human fire suppression acts to increase land carbon gain. The direct human effect on fire weakens the upward trend in global runoff throughout the century by 6% and enhances the upward trend in global evapotranspiration since ~ 1945 by 7%. In addition, the above impacts in densely populated, highly developed (if population density > 0.1 person/km2), or moderately populated and developed regions are of opposite sign to those in other regions. Our study suggests that particular attention should be paid to human deforestation and degradation fires in the tropical humid forests when reconstructing and projecting fire carbon emissions and net atmosphere-land carbon exchange and estimating resultant impacts of direct human effect on fire.

  10. Influence of firing temperature on the color properties of orthoferrite PrFeO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Luxová, Jana, E-mail: jana.luxova@upce.cz; Šulcová, Petra; Trojan, Miroslav

    2014-03-01

    Highlights: • PrFeO{sub 3} was prepared by solid state reaction in temperature region 1000–1500 °C. • Methods of thermal analysis were used for determination of thermal properties. • Pigments have different brown color hues depending on calcining temperature. • Pigment samples are applicable into glaze and organic matrix. • Single phase sample was prepared at higher temperatures of calcination. - Abstract: Orthoferrites belong to the large group of inorganic pigments and thanks to their excellent properties they have been widely used in various industries. Orthoferrite PrFeO{sub 3} with the perovskite structure was obtained in this work. This compound was synthesized with the solid state reaction by calcination in the temperature region 1000–1500 °C. The methods of thermal analysis were used for characterization of thermal behavior, formation and thermal stability of the tested orthoferrite. The main aim of this work was to study the influence of calcination temperature on the color properties of PrFeO{sub 3}. The color properties of powdered samples and the samples applied into ceramic transparent glaze and organic matrix in mass tone were also studied. The tested samples can be described by different brown color hues depending on calcining temperature. The phase composition of the powdered compounds was studied by X-ray diffraction analysis and the results of the powdered samples prepared at lower temperatures informed about the presence of several-phases compound. Particle size distribution of the samples was observed in dependence on calcination temperature too. The values of mean particle size of tested orthoferrites are moved from 3.9 to 18.5 μm. For preparation of orthoferrites with the excellent color properties the firing temperature 1200 °C is necessary.

  11. Site properties have a stronger influence than fire severity on ectomycorrhizal fungi and associated N-cycling bacteria in regenerating post-beetle-killed lodgepole pine forests.

    Science.gov (United States)

    Kennedy, Nabla M; Robertson, Susan J; Green, D Scott; Scholefield, Scott R; Arocena, Joselito M; Tackaberry, Linda E; Massicotte, Hugues B; Egger, Keith N

    2015-09-01

    Following a pine beetle epidemic in British Columbia, Canada, we investigated the effect of fire severity on rhizosphere soil chemistry and ectomycorrhizal fungi (ECM) and associated denitrifying and nitrogen (N)-fixing bacteria in the root systems of regenerating lodgepole pine seedlings at two site types (wet and dry) and three fire severities (low, moderate, and high). The site type was found to have a much larger impact on all measurements than fire severity. Wet and dry sites differed significantly for almost all soil properties measured, with higher values identified from wet types, except for pH and percent sand that were greater on dry sites. Fire severity caused few changes in soil chemical status. Generally, bacterial communities differed little, whereas ECM morphotype analysis revealed ectomycorrhizal diversity was lower on dry sites, with a corresponding division in community structure between wet and dry sites. Molecular profiling of the fungal ITS region confirmed these results, with a clear difference in community structure seen between wet and dry sites. The ability of ECM fungi to colonize seedlings growing in both wet and dry soils may positively contribute to subsequent regeneration. We conclude that despite consecutive landscape disturbances (mountain pine beetle infestation followed by wildfire), the "signature" of moisture on chemistry and ECM community structure remained pronounced.

  12. A Method of Fire Scenarios Identification in a Consolidated Fire Risk Analysis

    International Nuclear Information System (INIS)

    Lim, Ho Gon; Han, Sang Hoon; Yang, Joon Eon

    2010-01-01

    Conventional fire PSA consider only two cases of fire scenarios, that is one for fire without propagation and the other for single propagation to neighboring compartment. Recently, a consolidated fire risk analysis using single fault tree (FT) was developed. However, the fire scenario identification in the new method is similar to conventional fire analysis method. The present study develops a new method of fire scenario identification in a consolidated fire risk analysis method. An equation for fire propagation is developed to identify fire scenario and a mapping method of fire scenarios into internal event risk model is discussed. Finally, an algorithm for automatic program is suggested

  13. Fire and fire ecology: Concepts and principles

    Science.gov (United States)

    Mark A. Cochrane; Kevin C. Ryan

    2009-01-01

    Fire has been central to terrestrial life ever since early anaerobic microorganisms poisoned the atmosphere with oxygen and multicellular plant life moved onto land. The combination of fuels, oxygen, and heat gave birth to fire on Earth. Fire is not just another evolutionary challenge that life needed to overcome, it is, in fact, a core ecological process across much...

  14. Forest fires

    International Nuclear Information System (INIS)

    Fuller, M.

    1991-01-01

    This book examines the many complex and sensitive issues relating to wildland fires. Beginning with an overview of the fires of 1980s, the book discusses the implications of continued drought and considers the behavior of wildland fires, from ignition and spread to spotting and firestorms. Topics include the effects of weather, forest fuels, fire ecology, and the effects of fire on plants and animals. In addition, the book examines firefighting methods and equipment, including new minimum impact techniques and compressed air foam; prescribed burning; and steps that can be taken to protect individuals and human structures. A history of forest fire policies in the U.S. and a discussion of solutions to fire problems around the world completes the coverage. With one percent of the earth's surface burning every year in the last decade, this is a penetrating book on a subject of undeniable importance

  15. Probabilistic safety analysis for fire events for the NPP Isar 2

    International Nuclear Information System (INIS)

    Schmaltz, H.; Hristodulidis, A.

    2007-01-01

    The 'Probabilistic Safety Analysis for Fire Events' (Fire-PSA KKI2) for the NPP Isar 2 was performed in addition to the PSA for full power operation and considers all possible events which can be initiated due to a fire. The aim of the plant specific Fire-PSA was to perform a quantitative assessment of fire events during full power operation, which is state of the art. Based on simplistic assumptions referring to the fire induced failures, the influence of system- and component-failures on the frequency of the core damage states was analysed. The Fire-PSA considers events, which will result due to fire-induced failures of equipment on the one hand in a SCRAM and on the other hand in events, which will not have direct operational effects but because of the fire-induced failure of safety related installations the plant will be shut down as a precautionary measure. These events are considered because they may have a not negligible influence on the frequency of core damage states in case of failures during the plant shut down because of the reduced redundancy of safety related systems. (orig.)

  16. Detection and Characterization of Low Temperature Peat Fires during the 2015 Fire Catastrophe in Indonesia Using a New High-Sensitivity Fire Monitoring Satellite Sensor (FireBird)

    Science.gov (United States)

    Atwood, Elizabeth C.; Englhart, Sandra; Lorenz, Eckehard; Halle, Winfried; Wiedemann, Werner; Siegert, Florian

    2016-01-01

    Vast and disastrous fires occurred on Borneo during the 2015 dry season, pushing Indonesia into the top five carbon emitting countries. The region was affected by a very strong El Niño-Southern Oscillation (ENSO) climate phenomenon, on par with the last severe event in 1997/98. Fire dynamics in Central Kalimantan were investigated using an innovative sensor offering higher sensitivity to a wider range of fire intensities at a finer spatial resolution (160 m) than heretofore available. The sensor is onboard the TET-1 satellite, part of the German Aerospace Center (DLR) FireBird mission. TET-1 images (acquired every 2–3 days) from the middle infrared were used to detect fires continuously burning for almost three weeks in the protected peatlands of Sebangau National Park as well as surrounding areas with active logging and oil palm concessions. TET-1 detection capabilities were compared with MODIS active fire detection and Landsat burned area algorithms. Fire dynamics, including fire front propagation speed and area burned, were investigated. We show that TET-1 has improved detection capabilities over MODIS in monitoring low-intensity peatland fire fronts through thick smoke and haze. Analysis of fire dynamics revealed that the largest burned areas resulted from fire front lines started from multiple locations, and the highest propagation speeds were in excess of 500 m/day (all over peat > 2m deep). Fires were found to occur most often in concessions that contained drainage infrastructure but were not cleared prior to the fire season. Benefits of implementing this sensor system to improve current fire management techniques are discussed. Near real-time fire detection together with enhanced fire behavior monitoring capabilities would not only improve firefighting efforts, but also benefit analysis of fire impact on tropical peatlands, greenhouse gas emission estimations as well as mitigation measures to reduce severe fire events in the future. PMID:27486664

  17. Fine-particle sodium tracer for long-range transport of the Kuwaiti oil-fire smoke

    Energy Technology Data Exchange (ETDEWEB)

    Lowenthal, D.H.; Borys, R.D.; Rogers, C.F.; Chow, J.C.; Stevens, R.K.

    1993-04-23

    Evidence for long-range transport of the Kuwaiti oil-fire smoke during the months following the Persian Gulf War has been more or less indirect. However, more-recent data on the aerosol chemistry of Kuwaiti oil-fire plumes provides a direct link between those fires and aerosols collected at the Mauna Loa Observatory (MLO) during the late spring and summer of 1991. By itself, temporal covariation of fine-particle concentrations of elemental carbon, sulfur, and the noncrustal V/Zn ratio in MLO aerosols suggested a link to large-scale oil-combustion sources, but not necessarily to Kuwait. However, high concentrations of fine-particle (0.1-1.0 microm diameter) NaCl were observed in the 'white' oil-fire plumes over Kuwait during the summer of 1991. In the absence of other demonstratable sources of fine-particle Na, these relationships provide a direct link between the Kuwaiti oil-fires and aerosol composition observed at MLO. (Copyright (c) 1993 American Geophysical Union.)

  18. Optimizing Organophosphorus Fire Resistant Finish for Cotton Fabric Using Box-Behnken Design

    International Nuclear Information System (INIS)

    Sohail, Y.; Parag, B.; Nemeshwaree, B.; Giorgio, R.

    2016-01-01

    N-methylol dimethyl phosphono propionamide (MDPA) is one of the most utilized fire resistant (FR) finishes for cotton fabrics, utilized as part of a formulation with trimethylol melamine (TMM) to acquire better crosslinking and enhanced FR properties. The system parameters of the finishing treatment were upgraded for better FR properties and low mechanical loss to the fabric by the response surface methodology utilizing Box-Behnken statistical designed experimental strategy. The impacts of concentration on the cotton fabric’s properties (fire resistance and mechanical properties) were assessed with the regression equations. The optimum conditions by predicting the FR reagents focusing intact mechanical properties of the fabric were additionally studied. It was found that the parameters of crosslinking agents in the FR formulation have a prime role in the general FR properties of the cotton fabrics. The R-squared estimations of the considerable number of responses were above 92%, demonstrating the level of relationship between the predicted values by the Box-Behnken frameworks and the real test results.

  19. Browns Ferry fire

    International Nuclear Information System (INIS)

    Harkleroad, J.R.

    1983-01-01

    A synopsis of the March 22, 1975 fire at Browns Ferry Nuclear Plant is discussed. Emphasis is placed on events prior to and during the fire. How the fire started, fire fighting activities, fire and smoke development, and restoration activities are discussed

  20. Overview of the 2013 FireFlux II grass fire field experiment

    Science.gov (United States)

    C.B. Clements; B. Davis; D. Seto; J. Contezac; A. Kochanski; J.-B. Fillipi; N. Lareau; B. Barboni; B. Butler; S. Krueger; R. Ottmar; R. Vihnanek; W.E. Heilman; J. Flynn; M.A. Jenkins; J. Mandel; C. Teske; D. Jimenez; J. O' Brien; B. Lefer

    2014-01-01

    In order to better understand the dynamics of fire-atmosphere interactions and the role of micrometeorology on fire behaviour the FireFlux campaign was conducted in 2006 on a coastal tall-grass prairie in southeast Texas, USA. The FireFlux campaign dataset has become the international standard for evaluating coupled fire-atmosphere model systems. While FireFlux is one...

  1. Introducing the Global Fire WEather Database (GFWED)

    Science.gov (United States)

    Field, R. D.

    2015-12-01

    The Canadian Fire Weather Index (FWI) System is the mostly widely used fire danger rating system in the world. We have developed a global database of daily FWI System calculations beginning in 1980 called the Global Fire WEather Database (GFWED) gridded to a spatial resolution of 0.5° latitude by 2/3° longitude. Input weather data were obtained from the NASA Modern Era Retrospective-Analysis for Research (MERRA), and two different estimates of daily precipitation from rain gauges over land. FWI System Drought Code calculations from the gridded datasets were compared to calculations from individual weather station data for a representative set of 48 stations in North, Central and South America, Europe, Russia, Southeast Asia and Australia. Agreement between gridded calculations and the station-based calculations tended to be most different at low latitudes for strictly MERRA-based calculations. Strong biases could be seen in either direction: MERRA DC over the Mato Grosso in Brazil reached unrealistically high values exceeding DC=1500 during the dry season but was too low over Southeast Asia during the dry season. These biases are consistent with those previously-identified in MERRA's precipitation and reinforce the need to consider alternative sources of precipitation data. GFWED is being used by researchers around the world for analyzing historical relationships between fire weather and fire activity at large scales, in identifying large-scale atmosphere-ocean controls on fire weather, and calibration of FWI-based fire prediction models. These applications will be discussed. More information on GFWED can be found at http://data.giss.nasa.gov/impacts/gfwed/

  2. Peripheral facial nerve lesions induce changes in the firing properties of primary motor cortex layer 5 pyramidal cells.

    Science.gov (United States)

    Múnera, A; Cuestas, D M; Troncoso, J

    2012-10-25

    Facial nerve lesions elicit long-lasting changes in vibrissal primary motor cortex (M1) muscular representation in rodents. Reorganization of cortical representation has been attributed to potentiation of preexisting horizontal connections coming from neighboring muscle representation. However, changes in layer 5 pyramidal neuron activity induced by facial nerve lesion have not yet been explored. To do so, the effect of irreversible facial nerve injury on electrophysiological properties of layer 5 pyramidal neurons was characterized. Twenty-four adult male Wistar rats were randomly subjected to two experimental treatments: either surgical transection of mandibular and buccal branches of the facial nerve (n=18) or sham surgery (n=6). Unitary and population activity of vibrissal M1 layer 5 pyramidal neurons recorded in vivo under general anesthesia was compared between sham-operated and facial nerve-injured animals. Injured animals were allowed either one (n=6), three (n=6), or five (n=6) weeks recovery before recording in order to characterize the evolution of changes in electrophysiological activity. As compared to control, facial nerve-injured animals displayed the following sustained and significant changes in spontaneous activity: increased basal firing frequency, decreased spike-associated local field oscillation amplitude, and decreased spontaneous theta burst firing frequency. Significant changes in evoked-activity with whisker pad stimulation included: increased short latency population spike amplitude, decreased long latency population oscillations amplitude and frequency, and decreased peak frequency during evoked single-unit burst firing. Taken together, such changes demonstrate that peripheral facial nerve lesions induce robust and sustained changes of layer 5 pyramidal neurons in vibrissal motor cortex. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

  3. Model comparisons for estimating carbon emissions from North American wildland fire

    Science.gov (United States)

    Nancy H.F. French; William J. de Groot; Liza K. Jenkins; Brendan M. Rogers; Ernesto Alvarado; Brian Amiro; Bernardus De Jong; Scott Goetz; Elizabeth Hoy; Edward Hyer; Robert Keane; B.E. Law; Donald McKenzie; Steven G. McNulty; Roger Ottmar; Diego R. Perez-Salicrup; James Randerson; Kevin M. Robertson; Merritt. Turetsky

    2011-01-01

    Research activities focused on estimating the direct emissions of carbon from wildland fires across North America are reviewed as part of the North American Carbon Program disturbance synthesis. A comparison of methods to estimate the loss of carbon from the terrestrial biosphere to the atmosphere from wildland fires is presented. Published studies on emissions from...

  4. Post-fire Water Quality Response and Associated Physical Drivers

    Science.gov (United States)

    Rust, A.; Saxe, S.; Hogue, T. S.; McCray, J. E.; Rhoades, C.

    2017-12-01

    The frequency and severity of forest fires is increasing across the western US. Wildfires are known to impact water quality in receiving waters; many of which are important sources of water supply. Studies on individual forest fires have shown an increase in total suspended solids, nutrient and metal concentrations and loading in receiving streams. The current research looks at a large number of fires across a broad region (Western United States) to identify typical water quality changes after fire and the physical characteristics that drive those responses. This presentation will overview recent development of an extensive database on post-fire water quality. Across 172 fires, we found that water quality changed significantly in one out of three fires up to five years after the event compared to pre-burn conditions. For basins with higher frequency data, it was evident that water quality changes were significant in the first three years following fire. In both the initial years following fire and five years after fire, concentrations and loading rates of dissolved nutrients such as nitrite, nitrate and orthophosphate and particulate forms of nutrients, total organic nitrogen, total nitrogen, total phosphate, and total phosphorus increase thirty percent of the time. Concentrations of some major dissolved ions and metals decrease, with increased post-fire flows, while total particulate concentrations increased; the flux of both dissolved and particulate forms increase in thirty percent of the fires over five years. Water quality change is not uniform across the studied watersheds. A second goal of this study is to identify physical characteristics of a watershed that drive water quality response. Specifically, we investigate the physical, geochemical, and climatological characteristics of watersheds that control the type, direction, and magnitude of water quality change. Initial results reveal vegetation recovery is a key driver in post-fire water quality response

  5. Corrosion behaviour and surface analysis of a Co-Cr and two Ni-Cr dental alloys before and after simulated porcelain firing.

    Science.gov (United States)

    Qiu, Jing; Yu, Wei-Qiang; Zhang, Fu-Qiang; Smales, Roger J; Zhang, Yi-Lin; Lu, Chun-Hui

    2011-02-01

    This study evaluated the corrosion behaviour and surface properties of a commercial cobalt-chromium (Co-Cr) alloy and two nickel-chromium (Ni-Cr) alloys [beryllium (Be)-free and Be-containing] before and after a simulated porcelain-firing process. Before porcelain firing, the microstructure, surface composition and hardness, electrochemical corrosion properties, and metal-ion release of as-cast alloy specimens were examined. After firing, similar alloy specimens were examined for the same properties. In both as-cast and fired conditions, the Co-Cr alloy (Wirobond C) showed significantly more resistance to corrosion than the two Ni-Cr alloys. After firing, the corrosion rate of the Be-free Ni-Cr alloy (Stellite N9) increased significantly, which corresponded to a reduction in the levels of Cr, molybdenum (Mo), and Ni in the surface oxides and to a reduction in the thickness of the surface oxide film. The corrosion properties of the Co-Cr alloy and the Be-containing Ni-Cr alloy (ChangPing) were not significantly affected by the firing process. Porcelain firing also changed the microstructure and microhardness values of the alloys, and there were increases in the release of Co and Ni ions, especially for Ni from the Be-free Ni-Cr alloy. Thus, the corrosion rate of the Be-free Ni-Cr alloy increased significantly after porcelain firing, whereas the firing process had little effect on the corrosion susceptibility of the Co-Cr alloy and the Be-containing Ni-Cr alloy. © 2011 Eur J Oral Sci.

  6. Fire models for assessment of nuclear power plant fires

    International Nuclear Information System (INIS)

    Nicolette, V.F.; Nowlen, S.P.

    1989-01-01

    This paper reviews the state-of-the-art in available fire models for the assessment of nuclear power plants fires. The advantages and disadvantages of three basic types of fire models (zone, field, and control volume) and Sandia's experience with these models will be discussed. It is shown that the type of fire model selected to solve a particular problem should be based on the information that is required. Areas of concern which relate to all nuclear power plant fire models are identified. 17 refs., 6 figs

  7. Ash in fire affected ecosystems

    Science.gov (United States)

    Pereira, Paulo; Jordan, Antonio; Cerda, Artemi; Martin, Deborah

    2015-04-01

    Ash in fire affected ecosystems Ash lefts an important footprint in the ecosystems and has a key role in the immediate period after the fire (Bodi et al., 2014; Pereira et al., 2015). It is an important source of nutrients for plant recover (Pereira et al., 2014a), protects soil from erosion and controls soil hydrological process as runoff, infiltration and water repellency (Cerda and Doerr, 2008; Bodi et al., 2012, Pereira et al., 2014b). Despite the recognition of ash impact and contribution to ecosystems recuperation, it is assumed that we still have little knowledge about the implications of ash in fire affected areas. Regarding this situation we wanted to improve our knowledge in this field and understand the state of the research about fire ash around world. The special issue about "The role of ash in fire affected ecosystems" currently in publication in CATENA born from the necessity of joint efforts, identify research gaps, and discuss future cooperation in this interdisciplinary field. This is the first special issue about fire ash in the international literature. In total it will be published 10 papers focused in different aspects of the impacts of ash in fire affected ecosystems from several parts of the world: • Fire reconstruction using charcoal particles (Burjachs and Espositio, in press) • Ash slurries impact on rheological properties of Runoff (Burns and Gabet, in press) • Methods to analyse ash conductivity and sorbtivity in the laboratory and in the field (Balfour et al., in press) • Termogravimetric and hydrological properties of ash (Dlapa et al. in press) • Effects of ash cover in water infiltration (Leon et al., in press) • Impact of ash in volcanic soils (Dorta Almenar et al., in press; Escuday et al., in press) • Ash PAH and Chemical extracts (Silva et al., in press) • Microbiology (Barreiro et al., in press; Lombao et al., in press) We believe that this special issue will contribute importantly to the better understanding of

  8. [Factors affecting the vegetation restoration after fires in cold temperate wetlands: A review].

    Science.gov (United States)

    Zhao, Feng-Jun; Wang, Li-Zhong; Shu, Li-Fu; Chen, Peng-Yu; Chen, Li-guang

    2013-03-01

    Cold temperate wetland plays an important role in maintaining regional ecological balance. Fire is an important disturbance factor in wetland ecosystem. Severe burning can induce the marked degradation of the ecological functions of wetland ecosystem. The vegetation restoration, especially the early vegetation restoration, after fires, is the premise and basis for the recovery of the ecological functions of the ecosystem. This paper reviewed the research progress on the factors affecting the vegetation restoration after fires in wetlands. The vegetation restoration after fires in cold temperate wetlands was controlled by the fire intensity, fire size, vegetation types before fires, regeneration characteristics of plant species, and site conditions. It was considered that the long-term monitoring on the post-fire vegetation restoration in cold temperate wetland, the key factors affecting the vegetation restoration, the roles of frozen soil layer on the post-fire vegetation restoration, and the theories and technologies on the vegetation restoration would be the main research directions in the future.

  9. Research field of fire technology in Finland

    Science.gov (United States)

    Loikkanen, P.; Holm, C.

    1987-02-01

    The goal of the study is to give an overview of the whole diversified research field of fire technology and its problems. For this reason the research subjects have been grouped so that the responsibilities of different authorities, the legislation and specifications, various fields of technology, areas of industry, and groups of products could all be found as clearly as possible. The field has been divided into nine sub-areas. They are: general grounds, fire physics and chemistry, structural fire prevention, textiles and furnishings, devices for heating and other use, detection, fire fighting and rescue, quality control, and special problems. The sub-areas have been divided into 34 main subjects and these, excluding those of special problems, further into as many as 117 subject groups. Characteristics and problems of the sub-areas and the main subjects have been described. The subject groups have been characterized by key words and concepts which outline the projects. No concrete research projects and programs have, however, been directly suggested because their extent and contents depend essentially on financing and other available resources.

  10. THERMAL AND DIELECTRIC PROPERTIES OF PINE WOOD IN THE TRANSVERSE DIRECTION

    Directory of Open Access Journals (Sweden)

    Hamiyet Şahin Kol

    2009-11-01

    Full Text Available In this paper, the thermal conductivity and dielectric parameters for pine [Pinus sylvestris (L.] woods were determined in transverse directions for moisture conditions from oven-dry to 22 percent at a room temperature of 22 to 24 °C. Results indicate that the behaviors of thermal conductivity and dielectric parameters with moisture content and structural directions were similar. In general, the properties increased within the range studied with increasing moisture content. The radial values were similar to tangential values for both thermal conductivity and dielectric properties. The data presented here should be useful in most design problems where pine wood is subjected to microwave electric fields and heat changes.

  11. Nano-oxides to improve the surface properties of ceramic tiles

    International Nuclear Information System (INIS)

    Rambaldi, E.; Tucci, A.; Esposito, L.; Naldi, D.; Timellini, G.

    2010-01-01

    The aim of the present work is to realise ceramic tiles with superior surface mechanical characteristics and chemical resistance, by the addition of nano-oxides, such as zirconia and alumina, since such advanced ceramics oxides are well known for their excellent mechanical properties and good resistance to chemical etching. In order to avoid any dangerousness, the nanoparticles were used in form of aqueous suspension and they were sprayed, by airbrush, directly onto the dried ceramic support, before firing. To observe the distribution of the nanoparticles and to optimise the surface treatment, SEM-EDS analyses were carried out on the fired samples. XRD analysis was conducted to assess the phases evolution of the different materials during the firing step. The surface mechanical characteristics of the samples have been evaluated by Vickers hardness and scratch test. In addition, also chemical resistance tests were performed. Microstructural observations allowed to understand how alumina and zirconia nanoparticles acted to improve the surface performances of the modified ceramic tiles. (Author) 20 refs.

  12. “Use of fire extinguishers”—a new course with a new simulator

    CERN Multimedia

    HSE Unit & GS/FB

    2012-01-01

    Don’t wait, sign up! A new training course, “Handling of fire extinguishers”, is available since the beginning of March 2012. The training course is given by members of CERN’s Fire Brigade (GS-FB) and is intended for all members of personnel of CERN. Upon successful completion of the training course, you will be able to do the following: recognise a potentially combustible item and the various fire classes; choose the appropriate extinguisher for a given fire class; handle a fire extinguisher properly and efficiently; apply CERN's safety instructions. An important part of the training are the different firefighting exercises conducted using a new simulator, which makes it possible to simulate real conditions such as the following: a fire in the office; a fire in an electrical cabinet; a fire involving chemicals.        Don’t wait:  sign up for the training course directly ...

  13. WindWizard: A New Tool for Fire Management Decision Support

    Science.gov (United States)

    Bret W. Butler; Mark Finney; Larry Bradshaw; Jason Forthofer; Chuck McHugh; Rick Stratton; Dan Jimenez

    2006-01-01

    A new software tool has been developed to simulate surface wind speed and direction at the 100m to 300 m scale. This tool is useful when trying to estimate fire behavior in mountainous terrain. It is based on widely used computational fluid dynamics technology and has been tested against measured wind flows. In recent years it has been used to support fire management...

  14. Fire spread estimation on forest wildfire using ensemble kalman filter

    Science.gov (United States)

    Syarifah, Wardatus; Apriliani, Erna

    2018-04-01

    Wildfire is one of the most frequent disasters in the world, for example forest wildfire, causing population of forest decrease. Forest wildfire, whether naturally occurring or prescribed, are potential risks for ecosystems and human settlements. These risks can be managed by monitoring the weather, prescribing fires to limit available fuel, and creating firebreaks. With computer simulations we can predict and explore how fires may spread. The model of fire spread on forest wildfire was established to determine the fire properties. The fire spread model is prepared based on the equation of the diffusion reaction model. There are many methods to estimate the spread of fire. The Kalman Filter Ensemble Method is a modified estimation method of the Kalman Filter algorithm that can be used to estimate linear and non-linear system models. In this research will apply Ensemble Kalman Filter (EnKF) method to estimate the spread of fire on forest wildfire. Before applying the EnKF method, the fire spread model will be discreted using finite difference method. At the end, the analysis obtained illustrated by numerical simulation using software. The simulation results show that the Ensemble Kalman Filter method is closer to the system model when the ensemble value is greater, while the covariance value of the system model and the smaller the measurement.

  15. Fire Influences on Atmospheric Composition, Air Quality, and Climate

    Science.gov (United States)

    Voulgarakis, Apostolos; Field, Robert D.

    2015-01-01

    Fires impact atmospheric composition through their emissions, which range from long-lived gases to short-lived gases and aerosols. Effects are typically larger in the tropics and boreal regions but can also be substantial in highly populated areas in the northern mid-latitudes. In all regions, fire can impact air quality and health. Similarly, its effect on large-scale atmospheric processes, including regional and global atmospheric chemistry and climate forcing, can be substantial, but this remains largely unexplored. The impacts are primarily realised in the boundary layer and lower free troposphere but can also be noticeable in upper troposphere/lower stratosphere (UT/LS) region, for the most intense fires. In this review, we summarise the recent literature on findings related to fire impact on atmospheric composition, air quality and climate. We explore both observational and modelling approaches and present information on key regions and on the globe as a whole. We also discuss the current and future directions in this area of research, focusing on the major advances in emission estimates, the emerging efforts to include fire as a component in Earth system modelling and the use of modelling to assess health impacts of fire emissions.

  16. Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-19

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  17. Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-08

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

  18. Risk Assessment of the Main Control Room Fire Using Fire Simulations

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kilyoo; Jang, Seung Cheol

    2013-01-01

    KAERI is performing a fire PSA for a reference plant, Ulchin Unit 3, as part of developing the Korean site risk profile (KSRP). Fire simulations of the MCR fire were conducted using the CFAST (Consolidated Fire Growth and Smoke Transport) model and FDS (fire dynamic simulator) to improve the uncertainty in the MCR fire risk analysis. Using the fire simulation results, the MCR abandonment risk was evaluated. Level 1 PSA (probabilistic safety assessment) results of Ulchin Unit 3 using the EPRI PRA (probabilistic risk assessment) implementation guide showed that the MCR (main control room) fire was the main contributor to the core damage frequency. Recently, U. S. NRC and EPRI developed NUREG/CR-6850 to provide state-of-the-art methods, tools, and data for the conduct of a fire PSA for a commercial NPP

  19. Effects of fire and three fire-fighting chemicals on main soil properties, plant nutrient content and vegetation growth and cover after 10 years

    Energy Technology Data Exchange (ETDEWEB)

    Fernández-Fernández, M., E-mail: mariafernandez@iiag.csic.es; Gómez-Rey, M.X., E-mail: mxgomez@iiag.csic.es; González-Prieto, S.J., E-mail: serafin@iiag.csic.es

    2015-05-15

    The study addresses a knowledge-gap in the long-term ecological consequences of fire and fire-fighting chemicals. Ten years after a prescribed fire and the application of three fire-fighting chemicals, their effects on the soil–plant system were evaluated. Five treatments were established: unburnt soils (US) and burnt soils treated with water alone (BS), foaming agent (BS + Fo), Firesorb (BS + Fi) and ammonium polyphosphate (BS + Ap). Soils (0–2 cm depth) and foliar material of shrubs (Erica umbellata, Pterospartum tridentatum and Ulex micranthus) and trees (Pinus pinaster) were analysed for total N, δ{sup 15}N, and soil-available and plant total macronutrients and trace elements. Soil pH, NH{sub 4}{sup +}–N and NO{sub 3}{sup −}–N; pine basal diameter and height; and shrub cover and height were also measured. Compared with US plots, burnt soils had less nitrates and more Mo. Although differences were not always significant, BS + Ap had the highest levels of soil available P, Na and Al. Plants from BS + Ap plots had higher values of δ{sup 15}N (P. pinaster and E. umbellata), P (all species), Na (P. tridentatum and U. micranthus) and Mg (E. umbellata and P. tridentatum) than other treatments; while K in plants from BS + Ap plots was the highest among treatments for P. pinaster and the lowest for the shrubs. Pines in US plots were higher and wider than in burnt treatments, except for BS + Ap, where the tallest and widest trees were found, although half of them were either dead (the second highest mortality after BS + Fi) or had a distorted trunk. BS + Ap was the treatment with strongest effects on plants, showing E. umbellata the lowest coverage and height, P. tridentatum the highest coverage, U. micranthus one of the lowest coverages and being the only treatment where Genista triacanthos was absent. Consequently, it is concluded that both fire and ammonium polyphosphate application had significant effects on the soil–plant system after 10 years

  20. Fire simulation of the canister transfer and installation vehicle

    International Nuclear Information System (INIS)

    Peltokorpi, L.

    2012-12-01

    A pyrolysis model of the canister transfer and installation vehicle was developed and vehicle fires in the final disposal tunnel and in the central tunnel were simulated using the fire simulation program FDS (Fire Dynamics Simulator). For comparison, same vehicle fire was also simulated at conditions in which the fire remained as a fuel controlled during the whole simulation. The purpose of the fire simulations was to simulate the fire behaviour realistically taking into account for example the limitations coming from the lack of oxygen. The material parameters for the rubber were defined and the simulation models for the tyres developed by simulating the fire test of a front wheel loader rubber tyre done by SP Technical Research Institute of Sweden. In these simulations the most important phenomena were successfully brought out but the timing of the phenomena was difficult. The final values for the rubber material parameters were chosen so that the simulated fire behaviour was at least as intense as the measured one. In the vehicle fire simulations a hydraulic oil or diesel leak causing a pool fire size of 2 MW and 2 m 2 was assumed. The pool fire was assumed to be located under the tyres of the SPMT (Self Propelled Modular Transporters) transporter. In each of the vehicle fire simulations only the tyres of the SPMT transporter were observed to be burning whereas the tyres of the trailer remained untouched. In the fuel controlled fire the maximum power was slightly under 10 MW which was reached in about 18 minutes. In the final disposal tunnel the growth of the fire was limited due to the lack of oxygen and the relatively fast air flows existing in the tunnel. Fast air flows caused the flame spreading to be limited to the certain directions. In the final disposal tunnel fire the maximum power was slightly over 7 MW which was reached about 8 minutes after the ignition. In the central tunnel there was no shortage of oxygen but the spread of the fire was limited due