WorldWideScience

Sample records for direct measured dc-signals

  1. Experience with a PC-based system for noise and DC signal analysis in PWRs

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1996-01-01

    A data acquisition system that was originally developed for noise diagnostics in PWRs was expanded to include DC signal analysis in addition to noise analysis. The system has been used in PWRs for reactor diagnostics, determination of root cause of process anomalies, instrument calibration verification, measurement of drop time of control and shutdown rods, testing of timing and sequencing of control rod drive mechanisms, emergency diesel generator monitoring, etc. These applications are reviewed in this paper. (author)

  2. Direct neutrino mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Weinheimer, Christian, E-mail: weinheimer@uni-muenster.de [Westfaelische Wilhelms-Universitaet, Institut fuer Kernphysik (Germany)

    2013-03-15

    Direct neutrino mass experiments are complementary to searches for neutrinoless double {beta}-decay and to analyses of cosmological data. The previous tritium beta decay experiments at Mainz and at Troitsk have achieved upper limits on the neutrino mass of about 2 eV/c{sup 2} . The KATRIN experiment under construction will improve the neutrino mass sensitivity down to 200 meV/c{sup 2} by increasing strongly the statistics and-at the same time-reducing the systematic uncertainties. Huge improvements have been made to operate the system extremely stably and at very low background rate. The latter comprises new methods to reject secondary electrons from the walls as well as to avoid and to eject electrons stored in traps. As an alternative to tritium {beta}-decay experiments cryo-bolometers investigating the endpoint region of {sup 187}Re {beta}-decay or the electron capture of {sup 163}Ho are being developed. This article briefly reviews the current status of the direct neutrino mass measurements.

  3. Directional wave measurements and modelling

    Digital Repository Service at National Institute of Oceanography (India)

    Anand, N.M.; Nayak, B.U.; Bhat, S.S.; SanilKumar, V.

    Some of the results obtained from analysis of the monsoon directional wave data measured over 4 years in shallow waters off the west coast of India are presented. The directional spectrum computed from the time series data seems to indicate...

  4. Directed information measures in neuroscience

    CERN Document Server

    Vicente, Raul; Lizier, Joseph

    2014-01-01

    Analysis of information transfer has found rapid adoption in neuroscience, where a highly dynamic transfer of information continuously runs on top of the brain's slowly-changing anatomical connectivity. Measuring such transfer is crucial to understanding how flexible information routing and processing give rise to higher cognitive function. Directed Information Measures in Neuroscience reviews recent developments of concepts and tools for measuring information transfer, their application to neurophysiological recordings and analysis of interactions. Written by the most active researchers in the field the book discusses the state of the art, future prospects and challenges on the way to an efficient assessment of neuronal information transfer. Highlights include the theoretical quantification and practical estimation of information transfer, description of transfer locally in space and time, multivariate directed measures, information decomposition among a set of stimulus/responses variables, and the relation ...

  5. Direct measurements of neutrino masses

    Energy Technology Data Exchange (ETDEWEB)

    Holzschuh, E [Zurich Univ. (Switzerland). Inst. fuer Physik

    1996-11-01

    The direct measurements have so far given no indication for a nonzero (positive) mass of any of the three known neutrinos. The experiments measuring the tau and the muon neutrino are good shape. The tritium experiments are in an unfortunate situation. It is unclear to me whether the problems are experimental or theoretical or a combination of both. The electronic final states distribution have been calculated, but the results have never been tested experimentally. The most important question to be answered is about the validity of the sudden approximation. (author) 9 figs., 2 tabs., 16 refs.

  6. Direct measurements of neutrino mass

    International Nuclear Information System (INIS)

    Robertson, R.G.H.

    1991-01-01

    Some recent developments in the experimental search for neutrino mass are discussed. New data from Los Alamos on the electron neutrino mass as measured in tritium beta decay give an upper limit of 9.3 eV at the 95% confidence level. This result is not consistent with the long-standing ITEP result of 26(5) eV within a ''model-independent'' range of 17 to 40 eV. It now appears that the electron neutrino is not sufficiently massive to close the universe by itself. Hime and Jelley report finding new evidence for a 17-keV neutrino in the Β decay of 35 S and 63 Ni. Many other experiments are being reported and the situation is still unresolved. 56 refs., 1 fig., 3 tabs

  7. Wind measurement via direct detection lidar

    Science.gov (United States)

    Afek, I.; Sela, N.; Narkiss, N.; Shamai, G.; Tsadka, S.

    2013-10-01

    Wind sensing Lidar is considered a promising technology for high quality wind measurements required for various applications such as hub height wind resource assessment, power curve measurements and advanced, real time, forward looking turbine control. Until recently, the only available Lidar technology was based on coherent Doppler shift detection, whose market acceptance has been slow primarily due to its exuberant price. Direct detection Lidar technology provides an alternative to remote sensing of wind by incorporating high precision measurement, a robust design and an affordable price tag.

  8. Direct friction measurement in draw bead testing

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2005-01-01

    The application of draw beads in sheet metal stamping ensures controlled drawing-in of flange parts. Lubrication conditions in draw beads are severe due to sliding under simultaneous bending. Based on the original draw bead test design by Nine [1] comprehensive studies of friction in draw beads...... have been reported in literature. A major drawback in all these studies is that friction is not directly measured, but requires repeated measurements of the drawing force with and without relative sliding between the draw beads and the sheet material. This implies two tests with a fixed draw bead tool...... and a freely rotating tool respectively, an approach, which inevitably implies large uncertainties due to scatter in the experimental conditions. In order to avoid this problem a new draw bead test is proposed by the authors measuring the friction force acting on the tool radius directly by a build...

  9. Direct measurement of the W boson width

    Energy Technology Data Exchange (ETDEWEB)

    Abazov, V.M.; /Dubna, JINR; Abbott, B.; /Oklahoma U.; Abolins, M.; /Michigan State U.; Acharya, B.S.; /Tata Inst.; Adams, M.; /Illinois U., Chicago; Adams, T.; /Florida State U.; Aguilo, E.; /Alberta U. /Simon Fraser U. /McGill U.; Ahsan, M.; /Kansas State U.; Alexeev, G.D.; /Dubna, JINR; Alkhazov, G.; /St. Petersburg, INP; Alton, A.; /Michigan U. /Northeastern U.

    2009-09-01

    We present a direct measurement of the width of the W boson using the shape of the transverse mass distribution of W {yields} e{nu} candidates selected in 1 fb{sup -1} of data collected with the D0 detector at the Fermilab Tevatron collider in p{bar p} collisions at {radical}s = 1.96 TeV. We use the same methods and data sample that were used for our recently published W boson mass measurement, except for the modeling of the recoil, which is done with a new method based on a recoil library. Our result, 2.028 {+-} 0.072 GeV, is in agreement with the predictions of the standard model and is the most precise direct measurement result from a single experiment to date.

  10. Direct amplitude detuning measurement with ac dipole

    Directory of Open Access Journals (Sweden)

    S. White

    2013-07-01

    Full Text Available In circular machines, nonlinear dynamics can impact parameters such as beam lifetime and could result in limitations on the performance reach of the accelerator. Assessing and understanding these effects in experiments is essential to confirm the accuracy of the magnetic model and improve the machine performance. A direct measurement of the machine nonlinearities can be obtained by characterizing the dependency of the tune as a function of the amplitude of oscillations (usually defined as amplitude detuning. The conventional technique is to excite the beam to large amplitudes with a single kick and derive the tune from turn-by-turn data acquired with beam position monitors. Although this provides a very precise tune measurement it has the significant disadvantage of being destructive. An alternative, nondestructive way of exciting large amplitude oscillations is to use an ac dipole. The perturbation Hamiltonian in the presence of an ac dipole excitation shows a distinct behavior compared to the free oscillations which should be correctly taken into account in the interpretation of experimental data. The use of an ac dipole for direct amplitude detuning measurement requires careful data processing allowing one to observe the natural tune of the machine; the feasibility of such a measurement is demonstrated using experimental data from the Large Hadron Collider. An experimental proof of the theoretical derivations based on measurements performed at injection energy is provided as well as an application of this technique at top energy using a large number of excitations on the same beam.

  11. Is direct measurement of time possible?

    Science.gov (United States)

    Reynolds, Thomas

    2017-08-01

    Is direct measurement of time possible? The answer to this question may depend upon how one understands time. Is time an essential constituent of physical reality? Or is what scientists are talking about when they use the symbol ‘t’ or the word ‘time’ an human cultural construct, as the Chief of the USA NIST Divisions of Time and Frequency and of Quantum Physics has suggested. Few aspects of physics do not reference activity to time, but many discussions within either view of time seem to use one same, largely traditional, language of time. Briefly considering the question of measurement, including from a formal measure-theoretic point of view, clarifies the situation.

  12. Measuring Rock-Fluid Adhesion Directly

    Science.gov (United States)

    Tadmor, R.

    2017-12-01

    We show how to measure directly solid-liquid adhesion. We consider the normal adhesion, the work adhesion, and the lateral adhesion. The technique at the center of the method is Centrifugal Adhesion Balance (CAB) which allows coordinated manipulation of normal and lateral forces. For example: 1. It allows to induce an increase in the normal force which pulls on a liquid drop while keeping zero lateral force. This method mimics a drop that is subjected to a gravitational force that is gradually increasing. 2. It allows to increase the lateral force at zero normal force, mimicking zero gravity. From this one can obtain additional solid-liquid interaction parameters. When performing work of adhesion measurements, the values obtained are independent of drop size and are in agreement with theoretical predictions.

  13. Verification of the directivity index and other measures of directivity in predicting directional benefit

    Science.gov (United States)

    Dittberner, Andrew; Bentler, Ruth

    2005-09-01

    The relationship between various directivity measures and subject performance with directional microphone hearing aids was determined. Test devices included first- and second-order directional microphones. Recordings of sentences and noise (Hearing in Noise Test, HINT) were made through each test device in simple, complex, and anisotropic background noise conditions. Twenty-six subjects, with normal hearing, were administered the HINT test recordings, and directional benefit was computed. These measures were correlated to theoretical, free-field, and KEMAR DI values, as well as front-to-back ratios, in situ SNRs, and a newly proposed Db-SNR, wherein a predictive value of the SNR improvement is calculated as a function of the noise source incidence. The different predictive scores showed high correlation to the measured directional benefit scores in the complex (diffuse-like) background noise condition (r=0.89-0.97, pThe Db-SNR approach and the in situ SNR measures provided excellent prediction of subject performance in all background noise conditions (0.85-0.97, pthe predictive measures could account for the effects of reverberation on the speech signal (r=0.35-0.40, p<0.05).

  14. A sensor element for direct radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bajons, P.; Wernhart, U.; Zeiler, H. [University of Vienna (Austria). Institut of Material Physics

    1998-08-01

    A combination of a photodiode with a nonimaging light concentrator is developed to perform measurements of the direct solar radiation component. A prototype composed of low price elements is taken as a starting point to discuss the problems which must be faced when calibrating such sensors. By this the influence of the angle of incidence and spectral distribution (caused by different air mass or varying degree of clearness) of the incident radiation on the behavior of the system is studied. The readings are compared to the calculated (global minus diffuse) readings obtained from two standard star pyranometers. Finally the possibilities for increasing the accuracy of the sensor element and for applying the device are discussed. (author)

  15. Osmocapsules for direct measurement of osmotic strength.

    Science.gov (United States)

    Kim, Shin-Hyun; Lee, Tae Yong; Lee, Sang Seok

    2014-03-26

    Monodisperse microcapsules with ultra-thin membranes are microfluidically designed to be highly sensitive to osmotic pressure, thereby providing a tool for the direct measurement of the osmotic strength. To make such osmocapsules, water-in-oil-in-water double-emulsion drops with ultra-thin shells are prepared as templates through emulsification of core-sheath biphasic flow in a capillary microfluidic device. When photocurable monomers are used as the oil phase, the osmocapsules are prepared by in-situ photopolymerization of the monomers, resulting in semipermeable membranes with a relatively large ratio of membrane thickness to capsule radius, approximately 0.02. These osmocapsules are buckled by the outward flux of water when they are subjected to a positive osmotic pressure difference above 125 kPa. By contrast, evaporation-induced consolidation of middle-phase containing polymers enables the production of osmocapsules with a small ratio of membrane thickness to capsule radius of approximately 0.002. Such an ultra-thin membrane with semi-permeability makes the osmocapsules highly sensitive to osmotic pressure; a positive pressure as small as 12.5 kPa induces buckling of the capsules. By employing a set of distinct osmocapsules confining aqueous solutions with different osmotic strengths, the osmotic strength of unknown solutions can be estimated through observation of the capsules that are selectively buckled. This approach provides the efficient measurement of the osmotic strength using only a very small volume of liquid, thereby providing a useful alternative to other measurement methods which use complex setups. In addition, in-vivo measurement of the osmotic strength can be potentially accomplished by implanting these biocompatible osmocapsules into tissue, which is difficult to achieve using conventional methods. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Wave directional spectrum from array measurements

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A; Sarma, Y; Menon, H.B.

    Using the method of Esteva (1976, 1977), whcih assumes that at the frequency band the waves approach from just a single "mean" wave direction, wave direction has been consistently, accurately and unambiguously evaluated as a function of frequency...

  17. Electronegative Gas Thruster - Direct Thrust Measurement Project

    Science.gov (United States)

    Dankanich, John (Principal Investigator); Aanesland, Ane; Polzin, Kurt; Walker, Mitchell

    2015-01-01

    This effort is an international collaboration and academic partnership to mature an innovative electric propulsion (EP) thruster concept to TRL 3 through direct thrust measurement. The initial target application is for Small Satellites, but can be extended to higher power. The Plasma propulsion with Electronegative GASES (PEGASES) concept simplifies ion thruster operation, eliminates a neutralizer requirement and should yield longer life capabilities and lower cost implementation over conventional gridded ion engines. The basic proof-of concept has been demonstrated and matured to TRL 2 over the past several years by researchers at the Laboratoire de Physique des Plasma in France. Due to the low maturity of the innovation, there are currently no domestic investments in electronegative gas thrusters anywhere within NASA, industry or academia. The end product of this Center Innovation Fund (CIF) project will be a validation of the proof-of-concept, maturation to TRL 3 and technology assessment report to summarize the potential for the PEGASES concept to supplant the incumbent technology. Information exchange with the foreign national will be one-way with the exception of the test results. Those test results will first go through a standard public release ITAR/export control review, and the results will be presented in a public technical forum, and the results will be presented in a public technical forum.

  18. Electronegative Gas Thruster - Direct Thrust Measurement

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort is an international collaboration and academic partnership to mature an innovative electric propulsion (EP) thruster concept to TRL 3 through direct...

  19. Microparticle impact sensor measures energy directly

    Science.gov (United States)

    Alexander, W. M.; Berg, O. E.

    1965-01-01

    Construction of a capacitor sensor consisting of a dielectric layer between two conductive surface layers and connected across a potential source through a sensing resistor permits measurement of energy of impinging particles without degradation of sensitivity. A measurable response is produced without penetration of the dielectric layer.

  20. Implementing Measures of the Ecodesign Directive

    DEFF Research Database (Denmark)

    Andersen, Rikke Dorothea; Remmen, Arne

    2011-01-01

    on energy efficiency, power consumption, water consumption, information requirements and in some cases quality and performance issues. All IM only take the use phase of the products life time into consideration. The ambition level of the IM is analysed through a detailed case study of the IM for televisions....... It is argued that the IM have not succeeded in setting up sufficient ecodesign requirements, as only one life cycle phase and mainly one environmental impact category is addressed. The result of an analysis of televisions (TVs) on the market shows that new technologies have been developed that reduce power...... consumption significantly, and these technologies have been assessed not being mature enough to be included in the IM and the preparatory studies. Hence, it is concluded in this article that the process around the Ecodesign Directive has been too slow to be considered a driver for increasing material...

  1. Direct measurements of the magnetic entropy change

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Neves Bez, Henrique; von Moos, Lars

    2015-01-01

    An experimental device that can accurately measure the magnetic entropy change, Δs, as a function of temperature, T, and magnetic field, H, is presented. The magnetic field source is in this case a set of counter-rotating concentric Halbach-type magnets, which produce a highly homogeneous applied...... to the ambient are negligible in terms of the calorimetric determination of the magnetic entropy change, while the losses cannot be ignored when correcting for the actual sample temperature. We apply the device to two different types of samples; one is commercial grade Gd, i.e., a pure second-order phase...

  2. Direct measurement of tritium in urine by liquid scintillation method

    International Nuclear Information System (INIS)

    Zhang Caihong; Wen Qinghua; Chen Kefei; Li Huaixin

    1999-01-01

    The author introduces the method for direct measurement of tritium concentration in urine using liquid scintillation. Effects of sampling containers, store patterns and storage time are studied. Meanwhile, results of two methods are compared with direct measurement method and oxidation distillation method. The results shows that direct measurement method is a economic and simple method, which can meet the need of determination of urine tritium for NPP workers. There is no significant difference compared with the data obtained by oxidation distillation method

  3. Direct methods for radionuclides measurement in water environment

    International Nuclear Information System (INIS)

    Chernyaev, A.; Gaponov, I.; Kazennov, A.

    2004-01-01

    The paper is devoted to the direct method of anthropogenic radionuclide measurement in the water environment. Opportunities of application of submersible gamma-spectrometers for in situ underwater measurements of gamma-radiating nuclides and also the direct method for 90 Sr detection are considered

  4. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2006-01-01

    A special Bending-Under-Tension (BUT) transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all...... measured directly, thus enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication...

  5. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2004-01-01

    A special BUT-transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all measured directly, thus...... enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication in drawing of stainless steel...

  6. Accurate measurement of directional emittance of solar energy materials

    NARCIS (Netherlands)

    Nijnatten, van P.A.; Hugo-Le Gof, A.; Granqvist, C.-G.; Lampert, C.M.

    1992-01-01

    Directional emittance plays an important role in the calculation of radiative heat exchange. It partly determines the thermal insulation of single and multiple glazing and the efficiency of solar collectors. An emissiometer has been designed and built, capable for measurements of the directional

  7. Direct measurement of γ-emitting radionuclides in waste drum

    International Nuclear Information System (INIS)

    Ma Ruwei; Mao Yong; Zhang Xiuzhen; Xia Xiaobin; Guo Caiping; Han Yueqin

    1993-01-01

    The low-level rad waste produced from nuclear power plant, nuclear facilities, and in the process of their decommissioning is stored in waste depository. For the safety of transport and storage of these wastes, some test must be done. One of them is to analyse the kinds and activities of radionuclides in each waste drum. Segmented scanning gamma spectrum analysis can be used for direct measurement of gamma-emitting radionuclides in drum. Gamma emitters such as Co-60, Cs-137, Ra-226 can be measured directly from outside of drum. A method and system for direct measuring gamma emitters in waste drum are described, and measuring apparatus and measurement results as well

  8. Image analysis software versus direct anthropometry for breast measurements.

    Science.gov (United States)

    Quieregatto, Paulo Rogério; Hochman, Bernardo; Furtado, Fabianne; Machado, Aline Fernanda Perez; Sabino Neto, Miguel; Ferreira, Lydia Masako

    2014-10-01

    To compare breast measurements performed using the software packages ImageTool(r), AutoCAD(r) and Adobe Photoshop(r) with direct anthropometric measurements. Points were marked on the breasts and arms of 40 volunteer women aged between 18 and 60 years. When connecting the points, seven linear segments and one angular measurement on each half of the body, and one medial segment common to both body halves were defined. The volunteers were photographed in a standardized manner. Photogrammetric measurements were performed by three independent observers using the three software packages and compared to direct anthropometric measurements made with calipers and a protractor. Measurements obtained with AutoCAD(r) were the most reproducible and those made with ImageTool(r) were the most similar to direct anthropometry, while measurements with Adobe Photoshop(r) showed the largest differences. Except for angular measurements, significant differences were found between measurements of line segments made using the three software packages and those obtained by direct anthropometry. AutoCAD(r) provided the highest precision and intermediate accuracy; ImageTool(r) had the highest accuracy and lowest precision; and Adobe Photoshop(r) showed intermediate precision and the worst accuracy among the three software packages.

  9. Estimating Radar Velocity using Direction of Arrival Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Horndt, Volker [General Atomics Aeronautical Systems, Inc., San Diego, CA (United States); Bickel, Douglas Lloyd [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Naething, Richard M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    Direction of Arrival (DOA) measurements, as with a monopulse antenna, can be compared against Doppler measurements in a Synthetic Aperture Radar ( SAR ) image to determine an aircraft's forward velocity as well as its crab angle, to assist the aircraft's navigation as well as improving high - performance SAR image formation and spatial calibration.

  10. Direct Thermodynamic Measurements of the Energetics of Information Processing

    Science.gov (United States)

    2017-08-08

    Title: Direct thermodynamic measurements of the energetics of information processing Report Term: 0-Other Email : roukes@caltech.edu Distribution...INVESTIGATOR(S): Phone Number: 6263952916 Principal: Y Name: PhD Michael L. Roukes Email : roukes@caltech.edu PARTICIPANTS: Person Months Worked: 1.00... writing of this final DURIP report. These initial data directly demonstrate our ability to drive and detect nanomechanical motion at ultralow

  11. Direct liquid content measurement applicable for He II space cryostats

    International Nuclear Information System (INIS)

    Wanner, M.

    1988-01-01

    A direct calorimetric method for content measurement in the He II cryostat ISO was assessed. A well defined heat pulse into the He II bath causes a small temperature increase which can be measured and directly correlated to the liquid mass through the He II specific heat. To study this method under the potential zero gravity constraints of disconnected liquid volumes a setup was established for investigating heat transfer between separated liquid volumes. The results for different fluid configurations confirm that even for completely disconnected volumes the heat is almost immediately distributed throughout the whole liquid by evaporation and recondensation

  12. Directivity measurements in aluminum using a laser ultrasonics system

    International Nuclear Information System (INIS)

    Sakamoto, J M S; Pacheco, G M; Tittmann, B R; Baba, A

    2011-01-01

    A laser ultrasonics system was setup to measure the directivity (angular dependence pattern) of the amplitude of ultrasonic waves generated in aluminum samples. A pulsed Nd:YAG laser operating at 1064 nm optical wavelength, with typical pulse width (FWHM) of 8 ns, and energy per pulse of 450 mJ, was used to generate the ultrasound waves in the samples. The laser detection system was a Mach-Zehnder interferometer with typical noise-limited resolution of 0.25 nm (rms), frequency range from 50 kHz to 20 MHz, and measurement range from -75 nm/V to +75 nm/V. Two different optical spot sizes of the Nd:YAG laser were used to generate waves in the ablation regime: one was focused and the other was unfocused. Using the obtained data, the directivity graphics were drawn and compared with the theoretical curves, showing a good agreement. The experiments showed the directivity as a function of the optical spot size. For a point ultrasonic source (or focused optical spot), the directivity shows that the longitudinal waves present considerable amplitude in all directions. For a larger ultrasonic source (or an unfocused optical spot) the directivity shows that the longitudinal waves are generated with the higher amplitudes inside angles around ±10 0 .

  13. NEWSdm: Nuclear Emulsions for WIMP Search with directional measurement

    Directory of Open Access Journals (Sweden)

    Di Crescenzo A.

    2017-01-01

    Full Text Available Direct Dark Matter searches are nowadays one of the most exciting research topics. Several experimental efforts are concentrated on the development, construction, and operation of detectors looking for the scattering of target nuclei with Weakly Interactive Massive Particles (WIMPs. The measurement of the direction of WIMP-induced nuclear recoils is a challenging strategy to extend dark matter searches beyond the neutrino floor and provide an unambiguous signature of the detection of Galactic dark matter. Current directional experiments are based on the use of gas TPC whose sensitivity is strongly limited by the small achievable detector mass. We present an innovative directional experiment based on the use of a solid target made by newly developed nuclear emulsions and read-out systems reaching a position resolution of the order of 10 nm.

  14. NEWSdm: Nuclear Emulsions for WIMP Search with directional measurement

    Science.gov (United States)

    Di Crescenzo, A.

    2017-12-01

    Direct Dark Matter searches are nowadays one of the most exciting research topics. Several experimental efforts are concentrated on the development, construction, and operation of detectors looking for the scattering of target nuclei with Weakly Interactive Massive Particles (WIMPs). The measurement of the direction of WIMP-induced nuclear recoils is a challenging strategy to extend dark matter searches beyond the neutrino floor and provide an unambiguous signature of the detection of Galactic dark matter. Current directional experiments are based on the use of gas TPC whose sensitivity is strongly limited by the small achievable detector mass. We present an innovative directional experiment based on the use of a solid target made by newly developed nuclear emulsions and read-out systems reaching a position resolution of the order of 10 nm.

  15. Writer identification using directional ink-trace width measurements

    NARCIS (Netherlands)

    Brink, A. A.; Smit, J.; Bulacu, M. L.; Schomaker, L. R. B.

    As suggested by modern paleography, the width of ink traces is a powerful source of information for off-line writer identification, particularly if combined with its direction. Such measurements can be computed using simple, fast and accurate methods based on pixel contours, the combination of which

  16. Convergence of Algorithms for Reconstructing Convex Bodies and Directional Measures

    DEFF Research Database (Denmark)

    Gardner, Richard; Kiderlen, Markus; Milanfar, Peyman

    2006-01-01

    We investigate algorithms for reconstructing a convex body K in Rn from noisy measurements of its support function or its brightness function in k directions u1, . . . , uk. The key idea of these algorithms is to construct a convex polytope Pk whose support function (or brightness function) best...

  17. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  18. Performance analysis and evaluation of direct phase measuring deflectometry

    Science.gov (United States)

    Zhao, Ping; Gao, Nan; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian

    2018-04-01

    Three-dimensional (3D) shape measurement of specular objects plays an important role in intelligent manufacturing applications. Phase measuring deflectometry (PMD)-based methods are widely used to obtain the 3D shapes of specular surfaces because they offer the advantages of a large dynamic range, high measurement accuracy, full-field and noncontact operation, and automatic data processing. To enable measurement of specular objects with discontinuous and/or isolated surfaces, a direct PMD (DPMD) method has been developed to build a direct relationship between phase and depth. In this paper, a new virtual measurement system is presented and is used to optimize the system parameters and evaluate the system's performance in DPMD applications. Four system parameters are analyzed to obtain accurate measurement results. Experiments are performed using simulated and actual data and the results confirm the effects of these four parameters on the measurement results. Researchers can therefore select suitable system parameters for actual DPMD (including PMD) measurement systems to obtain the 3D shapes of specular objects with high accuracy.

  19. High-temperature ultrasonic measurements applied to directly heated samples

    International Nuclear Information System (INIS)

    Moore, R.I.; Taylor, R.E.

    1984-01-01

    High-temperature ultrasonic measurements of Young's modulus were made of graphite samples heated directly. The samples were cylindrical rods of the same geometry as that used in the multiproperty apparatus for simultaneous/consecutive measurements of a number of thermophysical properties to high temperatures. The samples were resonated in simple longitudinal vibration modes. Measurements were performed up to 2000 K. Incorporation of ultrasonic measurements of Young's modulus in the capabilities of the multiproperty apparatus is valuable because (i) ultrasonic measurements can be related to normal destructive measurements of this property; (ii) they can be used for screening materials or acceptance testing of specimens; (iii) they can be used to increase the understanding of thermophysical properties and property correlations. (author)

  20. Direct measurement of annual β dose using TLD on porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Xia Junding; Wang Weida; Zhou Zhixin

    1999-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of direct measurement of annual β dose using ultrathin TLD (CaSO 4 :Tm) on porcelain was studied. Since the TLD was placed into a hole left after sampling for the TL measurement, the method will not cause any new damage to the studied object. The results show that the technique is suitable for measuring annual β dose and improving accuracy of TL authentication test for both porcelain and pottery

  1. Measurement of proton momentum distributions using a direct geometry instrument

    International Nuclear Information System (INIS)

    Senesi, R; Andreani, C; Kolesnikov, A I

    2014-01-01

    We report the results of inelastic neutron scattering measurements on bulk water and ice using the direct geometry SEQUOIA chopper spectrometer at the Spallation Neutron Source (USA), with incident energy E i = 6 eV. In this set up the measurements allow to access the Deep Inelastic Neutron Scattering regime. The scattering is centred at the proton recoil energy given by the impulse approximation, and the shape of the recoil peak conveys information on the proton momentum distribution in the system. The comparison with the performance of inverse geometry instruments, such as VESUVIO at the ISIS source (UK), shows that complementary information can be accessed by the use of direct and inverse geometry instruments. Analysis of the neutron Compton profiles shows that the proton kinetic energy in ice at 271 K is larger than in room temperature liquid water, in agreement with previous measurements on VESUVIO

  2. Comparison of NWP wind speeds and directions to measured wind speeds and directions

    DEFF Research Database (Denmark)

    Astrup, Poul; Mikkelsen, Torben

    Numerical Weather Predictions (NWP) of wind speed and direction has been compared to measurements for seven German sites for nuclear power plants, and for Risø, the site of the Danish nuclear research reactors now being decommissioned . For the German sites the data cover approximately three month...

  3. DI3 - A New Procedure for Absolute Directional Measurements

    Directory of Open Access Journals (Sweden)

    A Geese

    2011-06-01

    Full Text Available The standard observatory procedure for determining a geomagnetic field's declination and inclination absolutely is the DI-flux measurement. The instrument consists of a non-magnetic theodolite equipped with a single-axis fluxgate magnetometer. Additionally, a scalar magnetometer is needed to provide all three components of the field. Using only 12 measurement steps, all systematic errors can be accounted for, but if only one of the readings is wrong, the whole measurement has to be rejected. We use a three-component sensor on top of the theodolites telescope. By performing more measurement steps, we gain much better control of the whole procedure: As the magnetometer can be fully calibrated by rotating about two independent directions, every combined reading of magnetometer output and theodolite angles provides the absolute field vector. We predefined a set of angle positions that the observer has to try to achieve. To further simplify the measurement procedure, the observer is guided by a pocket pc, in which he has only to confirm the theodolite position. The magnetic field is then stored automatically, together with the horizontal and vertical angles. The DI3 measurement is periodically performed at the Niemegk Observatory, allowing for a direct comparison with the traditional measurements.

  4. Direct shaft torque measurements in a transient turbine facility

    International Nuclear Information System (INIS)

    Beard, Paul F; Povey, Thomas

    2011-01-01

    This paper describes the development and implementation of a shaft torque measurement system for the Oxford Turbine Research Facility (formerly the Turbine Test Facility (TTF) at QinetiQ, Farnborough), or OTRF. As part of the recent EU TATEF II programme, the facility was upgraded to allow turbine efficiency measurements to be performed. A shaft torque measurement system was developed as part of this upgrade. The system is unique in that, to the authors' knowledge, it provided the first direct measurement of shaft torque in a transient turbine facility although the system has wider applicability to rotating test facilities in which power measurement is a requirement. The adopted approach removes the requirement to quantify bearing friction, which can be difficult to accurately calibrate under representative operating conditions. The OTRF is a short duration (approximately 0.4 s run time) isentropic light-piston facility capable of matching all of the non-dimensional parameters important for aerodynamic and heat studies, namely Mach number, Reynolds number, non-dimensional speed, stage pressure ratio and gas-to-wall temperature ratio. The single-stage MT1 turbine used for this study is a highly loaded unshrouded design, and as such is relevant to modern military, or future civil aero-engine design. Shaft torque was measured directly using a custom-built strain gauge-based torque measurement system in the rotating frame of reference. This paper describes the development of this measurement system. The system was calibrated, including the effects of temperature, to a traceable primary standard using a purpose-built facility. The bias and precision uncertainties of the measured torque were ±0.117% and ±0.183%, respectively. To accurately determine the shaft torque developed by a turbine in the OTRF, small corrections due to inertial torque (associated with changes in the rotational speed) and aerodynamic drag (windage) are required. The methods for performing these

  5. Direct measurements of transport properties are essential for site characterization

    International Nuclear Information System (INIS)

    Wright, J.; Conca, J.L.

    1994-08-01

    Direct measurements of transport parameters on subsurface sediments using, the UFA method provided detailed hydrostratigraphic mapping, and subsurface flux distributions at a mixed-waste disposal site at Hanford. Seven hundred unsaturated conductivity measurements on fifty samples were obtained in only six months total of UFA run time. These data are used to provide realistic information to conceptual models, predictive models and restoration strategies. The UFA instrument consists of an ultracentrifuge with a constant, ultralow flow pump that provides fluid to the sample surface through a rotating seal assembly and microdispersal system. Effluent from the sample is collected in a transparent, volumetrically-calibrated chamber at the bottom of the sample assembly. Using a strobe light, an observer can check the chamber while the sample is being centrifuged. Materials can be run in the UFA as recomposited samples or in situ samples can be subcored directly into the sample UFA chamber

  6. Direct measurement of skin friction with a new instrument

    Science.gov (United States)

    Vakili, A. D.; Wu, J. M.

    1986-01-01

    The design and performance of a small belt-type skin-friction gage to measure wall shear-stress coefficients in wind-tunnel testing are described, summarizing the report of Vakili and Wu (1982). The sensor employs a flexible belt of variable surface characteristics; this belt, wrapped tightly around two cylinders mounted on frictionless flexures, is equipped with strain gages to estimate the deflection of the belt by the flow. An alternative approach uses IR illumination, optical fibers, and a photosensitive transistor, permitting direct measurement of the belt deflection. Drawings, diagrams, and graphs of sample data are provided.

  7. Direct nn-Scattering Measurement With the Pulsed Reactor YAGUAR.

    Science.gov (United States)

    Mitchell, G E; Furman, W I; Lychagin, E V; Muzichka, A Yu; Nekhaev, G V; Strelkov, A V; Sharapov, E I; Shvetsov, V N; Chernuhin, Yu I; Levakov, B G; Litvin, V I; Lyzhin, A E; Magda, E P; Crawford, B E; Stephenson, S L; Howell, C R; Tornow, W

    2005-01-01

    Although crucial for resolving the issue of charge symmetry in the nuclear force, direct measurement of nn-scattering by colliding free neutrons has never been performed. At present the Russian pulsed reactor YAGUAR is the best neutron source for performing such a measurement. It has a through channel where the neutron moderator is installed. The neutrons are counted by a neutron detector located 12 m from the reactor. In preliminary experiments an instantaneous value of 1.1 × 10(18)/cm(2)s was obtained for the thermal neutron flux density. The experiment will be performed by the DIANNA Collaboration as International Science & Technology Center (ISTC) project No. 2286.

  8. Radar velocity determination using direction of arrival measurements

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W.; Bickel, Douglas L.; Naething, Richard M.; Horndt, Volker

    2017-12-19

    The various technologies presented herein relate to utilizing direction of arrival (DOA) data to determine various flight parameters for an aircraft A plurality of radar images (e.g., SAR images) can be analyzed to identify a plurality of pixels in the radar images relating to one or more ground targets. In an embodiment, the plurality of pixels can be selected based upon the pixels exceeding a SNR threshold. The DOA data in conjunction with a measurable Doppler frequency for each pixel can be obtained. Multi-aperture technology enables derivation of an independent measure of DOA to each pixel based on interferometric analysis. This independent measure of DOA enables decoupling of the aircraft velocity from the DOA in a range-Doppler map, thereby enabling determination of a radar velocity. The determined aircraft velocity can be utilized to update an onboard INS, and to keep it aligned, without the need for additional velocity-measuring instrumentation.

  9. Transportable IOT measurement station for direct-broadcast satellites

    Science.gov (United States)

    Ulbricht, Michael

    A transportable 11.7-12.5-GHz flux-density measurement facility for use in the in-orbit testing (IOT) of the FRG TV-Sat direct-broadcast satellites is described. Major components include a 1.2-m-diameter antenna, the fluxmeter, a radiometer to determine atmospheric attenuation, a weather station, and a control and data-processing computer; all of the components are mounted on a 5.10 x 2.35 x 2.70-m trailer. IOT performance parameters include gain/temperature ratio 15.9 dB/K, measurement range -97 to -117 dBW/sq m, measurement accuracy less than 0.5 dB rms, and measurement rate 250-650 msec. Photographs and a block diagram are provided.

  10. Direct Measurement of the Surface Energy of Graphene.

    Science.gov (United States)

    van Engers, Christian D; Cousens, Nico E A; Babenko, Vitaliy; Britton, Jude; Zappone, Bruno; Grobert, Nicole; Perkin, Susan

    2017-06-14

    Graphene produced by chemical vapor deposition (CVD) is a promising candidate for implementing graphene in a range of technologies. In most device configurations, one side of the graphene is supported by a solid substrate, wheras the other side is in contact with a medium of interest, such as a liquid or other two-dimensional material within a van der Waals stack. In such devices, graphene interacts on both faces via noncovalent interactions and therefore surface energies are key parameters for device fabrication and operation. In this work, we directly measured adhesive forces and surface energies of CVD-grown graphene in dry nitrogen, water, and sodium cholate using a modified surface force balance. For this, we fabricated large (∼1 cm 2 ) and clean graphene-coated surfaces with smooth topography at both macro- and nanoscales. By bringing two such surfaces into contact and measuring the force required to separate them, we measured the surface energy of single-layer graphene in dry nitrogen to be 115 ± 4 mJ/m 2 , which was similar to that of few-layer graphene (119 ± 3 mJ/m 2 ). In water and sodium cholate, we measured interfacial energies of 83 ± 7 and 29 ± 6 mJ/m 2 , respectively. Our work provides the first direct measurement of graphene surface energy and is expected to have an impact both on the development of graphene-based devices and contribute to the fundamental understanding of surface interactions.

  11. Direct Measurement of Photon Recoil from a Levitated Nanoparticle

    Science.gov (United States)

    Jain, Vijay; Gieseler, Jan; Moritz, Clemens; Dellago, Christoph; Quidant, Romain; Novotny, Lukas

    2016-06-01

    The momentum transfer between a photon and an object defines a fundamental limit for the precision with which the object can be measured. If the object oscillates at a frequency Ω0 , this measurement backaction adds quanta ℏΩ0 to the oscillator's energy at a rate Γrecoil, a process called photon recoil heating, and sets bounds to coherence times in cavity optomechanical systems. Here, we use an optically levitated nanoparticle in ultrahigh vacuum to directly measure Γrecoil. By means of a phase-sensitive feedback scheme, we cool the harmonic motion of the nanoparticle from ambient to microkelvin temperatures and measure its reheating rate under the influence of the radiation field. The recoil heating rate is measured for different particle sizes and for different excitation powers, without the need for cavity optics or cryogenic environments. The measurements are in quantitative agreement with theoretical predictions and provide valuable guidance for the realization of quantum ground-state cooling protocols and the measurement of ultrasmall forces.

  12. Strong Measurements Give a Better Direct Measurement of the Quantum Wave Function.

    Science.gov (United States)

    Vallone, Giuseppe; Dequal, Daniele

    2016-01-29

    Weak measurements have thus far been considered instrumental in the so-called direct measurement of the quantum wave function [4J. S. Lundeen, Nature (London) 474, 188 (2011).]. Here we show that a direct measurement of the wave function can be obtained by using measurements of arbitrary strength. In particular, in the case of strong measurements, i.e., those in which the coupling between the system and the measuring apparatus is maximum, we compared the precision and the accuracy of the two methods, by showing that strong measurements outperform weak measurements in both for arbitrary quantum states in most cases. We also give the exact expression of the difference between the original and reconstructed wave function obtained by the weak measurement approach; this will allow one to define the range of applicability of such a method.

  13. Directly Measuring the Degree of Quantum Coherence using Interference Fringes

    Science.gov (United States)

    Wang, Yi-Tao; Tang, Jian-Shun; Wei, Zhi-Yuan; Yu, Shang; Ke, Zhi-Jin; Xu, Xiao-Ye; Li, Chuan-Feng; Guo, Guang-Can

    2017-01-01

    Quantum coherence is the most distinguished feature of quantum mechanics. It lies at the heart of the quantum-information technologies as the fundamental resource and is also related to other quantum resources, including entanglement. It plays a critical role in various fields, even in biology. Nevertheless, the rigorous and systematic resource-theoretic framework of coherence has just been developed recently, and several coherence measures are proposed. Experimentally, the usual method to measure coherence is to perform state tomography and use mathematical expressions. Here, we alternatively develop a method to measure coherence directly using its most essential behavior—the interference fringes. The ancilla states are mixed into the target state with various ratios, and the minimal ratio that makes the interference fringes of the "mixed state" vanish is taken as the quantity of coherence. We also use the witness observable to witness coherence, and the optimal witness constitutes another direct method to measure coherence. For comparison, we perform tomography and calculate l1 norm of coherence, which coincides with the results of the other two methods in our situation. Our methods are explicit and robust, providing a nice alternative to the tomographic technique.

  14. Precision Photometric Extinction Corrections from Direct Atmospheric Measurements

    Science.gov (United States)

    McGraw, John T.; Zimmer, P.; Linford, J.; Simon, T.; Measurement Astrophysics Research Group

    2009-01-01

    For decades astronomical extinction corrections have been accomplished using nightly mean extinction coefficients derived from Langley plots measured with the same telescope used for photometry. Because this technique results in lost time on program fields, observers only grudgingly made sporadic extinction measurements. Occasionally extinction corrections are not measured nightly but are made using tabulated mean monthly or even quarterly extinction coefficients. Any observer of the sky knows that Earth's atmosphere is an ever-changing fluid in which is embedded extinction sources ranging from Rayleigh (molecular) scattering to aerosol, smoke and dust scattering and absorption, to "just plain cloudy.” Our eyes also tell us that the type, direction and degree of extinction changes on time scales of minutes or less - typically shorter than many astronomical observations. Thus, we should expect that atmospheric extinction can change significantly during a single observation. Mean extinction coefficients might be well-defined nightly means, but those means have high variance because they do not accurately record the wavelength-, time-, and angle-dependent extinction actually affecting each observation. Our research group is implementing lidar measurements made in the direction of observation with one minute cadence, from which the absolute monochromatic extinction can be measured. Simultaneous spectrophotometry of nearby bright standard stars allows derivation and MODTRAN modeling atmospheric transmission as a function of wavelength for the atmosphere through which an observation is made. Application of this technique is demonstrated. Accurate real-time extinction measurements are an enabling factor for sub-1% photometry. This research is supported by NSF Grant 0421087 and AFRL Grant #FA9451-04-2-0355.

  15. Direct measurements of intermolecular forces by chemical force microscopy

    Science.gov (United States)

    Vezenov, Dmitri Vitalievich

    1999-12-01

    Detailed description of intermolecular forces is key to understanding a wide range of phenomena from molecular recognition to materials failure. The unique features of atomic force microscopy (AFM) to make point contact force measurements with ultra high sensitivity and to generate spatial maps of surface topography and forces have been extended to include measurements between well-defined organic molecular groups. Chemical modification of AFM probes with self-assembled monolayers (SAMs) was used to make them sensitive to specific molecular interactions. This novel chemical force microscopy (CFM) technique was used to probe forces between different molecular groups in a range of environments (vacuum, organic liquids and aqueous solutions); measure surface energetics on a nanometer scale; determine pK values of the surface acid and base groups; measure forces to stretch and unbind a short synthetic DNA duplex and map the spatial distribution of specific functional groups and their ionization state. Studies of adhesion forces demonstrated the important contribution of hydrogen bonding to interactions between simple organic functionalities. The chemical identity of the tip and substrate surfaces as well as the medium had a dramatic effect on adhesion between model monolayers. A direct correlation between surface free energy and adhesion forces was established. The adhesion between epoxy polymer and model mixed SAMs varied with the amount of hydrogen bonding component in the monolayers. A consistent interpretation of CFM measurements in polar solvents was provided by contact mechanics models and intermolecular force components theory. Forces between tips and surfaces functionalized with SAMs terminating in acid or base groups depended on their ionization state. A novel method of force titration was introduced for highly local characterization of the pK's of surface functional groups. The pH-dependent changes in friction forces were exploited to map spatially the

  16. Activity plan: Directional drilling and environmental measurements while drilling

    International Nuclear Information System (INIS)

    Myers, D.A.

    1998-01-01

    This activity plan describes the testing of directional drilling combined with environmental measurements while drilling at two Hanford Site locations. A cold test is to be conducted at the 105A Mock Tank Leak Facility in the 200 East Area. A hot test is proposed to be run at the 216-B-8 tile field north of the 241-B Tank Farm in 200 East Area. Criteria to judge the success, partial success or failure of various aspects of the test are included. The TWRS program is assessing the potential for use of directional drilling because of an identified need to interrogate the vadose zone beneath the single-shell tanks. Because every precaution must be taken to assure that investigation activities do not violate the integrity of the tanks, control of the drill bit and ability to follow a predetermined drill path are of utmost importance and are being tested

  17. Measuring directional urban spatial interaction in China: A migration perspective.

    Science.gov (United States)

    Li, Fangzhou; Feng, Zhiming; Li, Peng; You, Zhen

    2017-01-01

    The study of urban spatial interaction is closely linked to that of economic geography, urban planning, regional development, and so on. Currently, this topic is generating a great deal of interest among researchers who are striving to find accurate ways to measure urban spatial interaction. Classical spatial interaction models lack theoretical guidance and require complicated parameter-adjusting processes. The radiation model, however, as proposed by Simini et al. with rigorous formula derivation, can simulate directional urban spatial interaction. We applied the radiation model in China to simulate the directional migration number among 337 nationwide research units, comprising 4 municipalities and 333 prefecture-level cities. We then analyzed the overall situation in Chinese cities, the interaction intensity hierarchy, and the prime urban agglomerations from the perspective of migration. This was done to ascertain China's urban spatial interaction and regional development from 2000 to 2010 to reveal ground realities.

  18. Activity plan: Directional drilling and environmental measurements while drilling

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.A.

    1998-07-16

    This activity plan describes the testing of directional drilling combined with environmental measurements while drilling at two Hanford Site locations. A cold test is to be conducted at the 105A Mock Tank Leak Facility in the 200 East Area. A hot test is proposed to be run at the 216-B-8 tile field north of the 241-B Tank Farm in 200 East Area. Criteria to judge the success, partial success or failure of various aspects of the test are included. The TWRS program is assessing the potential for use of directional drilling because of an identified need to interrogate the vadose zone beneath the single-shell tanks. Because every precaution must be taken to assure that investigation activities do not violate the integrity of the tanks, control of the drill bit and ability to follow a predetermined drill path are of utmost importance and are being tested.

  19. Direct measurement of the intrinsic ankle stiffness during standing.

    Science.gov (United States)

    Vlutters, M; Boonstra, T A; Schouten, A C; van der Kooij, H

    2015-05-01

    Ankle stiffness contributes to standing balance, counteracting the destabilizing effect of gravity. The ankle stiffness together with the compliance between the foot and the support surface make up the ankle-foot stiffness, which is relevant to quiet standing. The contribution of the intrinsic ankle-foot stiffness to balance, and the ankle-foot stiffness amplitude dependency remain a topic of debate in the literature. We therefore developed an experimental protocol to directly measure the bilateral intrinsic ankle-foot stiffness during standing balance, and determine its amplitude dependency. By applying fast (40 ms) ramp-and-hold support surface rotations (0.005-0.08 rad) during standing, reflexive contributions could be excluded, and the amplitude dependency of the intrinsic ankle-foot stiffness was investigated. Results showed that reflexive activity could not have biased the torque used for estimating the intrinsic stiffness. Furthermore, subjects required less recovery action to restore balance after bilateral rotations in opposite directions compared to rotations in the same direction. The intrinsic ankle-foot stiffness appears insufficient to ensure balance, ranging from 0.93±0.09 to 0.44±0.06 (normalized to critical stiffness 'mgh'). This implies that changes in muscle activation are required to maintain balance. The non-linear stiffness decrease with increasing rotation amplitude supports the previous published research. With the proposed method reflexive effects can be ruled out from the measured torque without any model assumptions, allowing direct estimation of intrinsic stiffness during standing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. LEAD SLOWING DOWN SPECTROSCOPY FOR DIRECT Pu MASS MEASUREMENTS

    International Nuclear Information System (INIS)

    Ressler, Jennifer J.; Smith, Leon E.; Anderson, Kevin K.

    2008-01-01

    The direct measurement of Pu in previously irradiated fuel assemblies is a recognized need in the international safeguards community. A suitable technology could support more timely and independent material control and accounting (MC and A) measurements at nuclear fuel storage areas, the head-end of reprocessing facilities, and at the product-end of recycled fuel fabrication. Lead slowing down spectroscopy (LSDS) may be a viable solution for directly measuring not only the mass of 239Pu in fuel assemblies, but also the masses of other fissile isotopes such as 235U and 241Pu. To assess the potential viability of LSDS, an LSDS spectrometer was modeled in MCNP5 and 'virtual assays' of nominal PWR assemblies ranging from 0 to 60 GWd/MTU burnup were completed. Signal extraction methods, including the incorporation of nonlinear fitting to account for self-shielding effects in strong resonance regions, are described. Quantitative estimates of Pu uncertainty are given for simplistic and more realistic fuel isotopic inventories calculated using ORIGEN. A discussion of additional signal-perturbing effects that will be addressed in future work, and potential signal extraction approaches that could improve Pu mass uncertainties, are also discussed

  1. Directly measured secondhand smoke exposure and COPD health outcomes

    Directory of Open Access Journals (Sweden)

    Balmes John

    2006-06-01

    Full Text Available Abstract Background Although personal cigarette smoking is the most important cause and modulator of chronic obstructive pulmonary disease (COPD, secondhand smoke (SHS exposure could influence the course of the disease. Despite the importance of this question, the impact of SHS exposure on COPD health outcomes remains unknown. Methods We used data from two waves of a population-based multiwave U.S. cohort study of adults with COPD. 77 non-smoking respondents with a diagnosis of COPD completed direct SHS monitoring based on urine cotinine and a personal badge that measures nicotine. We evaluated the longitudinal impact of SHS exposure on validated measures of COPD severity, physical health status, quality of life (QOL, and dyspnea measured at one year follow-up. Results The highest level of SHS exposure, as measured by urine cotinine, was cross-sectionally associated with poorer COPD severity (mean score increment 4.7 pts; 95% CI 0.6 to 8.9 and dyspnea (1.0 pts; 95% CI 0.4 to 1.7 after controlling for covariates. In longitudinal analysis, the highest level of baseline cotinine was associated with worse COPD severity (4.7 points; 95% CI -0.1 to 9.4; p = 0.054, disease-specific QOL (2.9 pts; -0.16 to 5.9; p = 0.063, and dyspnea (0.9 pts; 95% CI 0.2 to 1.6 pts; p Conclusion Directly measured SHS exposure appears to adversely influence health outcomes in COPD, independent of personal smoking. Because SHS is a modifiable risk factor, clinicians should assess SHS exposure in their patients and counsel its avoidance. In public health terms, the effects of SHS exposure on this vulnerable subpopulation provide a further rationale for laws prohibiting public smoking.

  2. Probing Anisotropic Surface Properties of Molybdenite by Direct Force Measurements.

    Science.gov (United States)

    Lu, Zhenzhen; Liu, Qingxia; Xu, Zhenghe; Zeng, Hongbo

    2015-10-27

    Probing anisotropic surface properties of layer-type mineral is fundamentally important in understanding its surface charge and wettability for a variety of applications. In this study, the surface properties of the face and the edge surfaces of natural molybdenite (MoS2) were investigated by direct surface force measurements using atomic force microscope (AFM). The interaction forces between the AFM tip (Si3N4) and face or edge surface of molybdenite were measured in 10 mM NaCl solutions at various pHs. The force profiles were well-fitted with classical DLVO (Derjaguin-Landau-Verwey-Overbeek) theory to determine the surface potentials of the face and the edge surfaces of molybdenite. The surface potentials of both the face and edge surfaces become more negative with increasing pH. At neutral and alkaline conditions, the edge surface exhibits more negative surface potential than the face surface, which is possibly due to molybdate and hydromolybdate ions on the edge surface. The point of zero charge (PZC) of the edge surface was determined around pH 3 while PZC of the face surface was not observed in the range of pH 3-11. The interaction forces between octadecyltrichlorosilane-treated AFM tip (OTS-tip) and face or edge surface of molybdenite were also measured at various pHs to study the wettability of molybdenite surfaces. An attractive force between the OTS-tip and the face surface was detected. The force profiles were well-fitted by considering DLVO forces and additional hydrophobic force. Our results suggest the hydrophobic feature of the face surface of molybdenite. In contrast, no attractive force between the OTS-tip and the edge surface was detected. This is the first study in directly measuring surface charge and wettability of the pristine face and edge surfaces of molybdenite through surface force measurements.

  3. GMTI Direction of Arrival Measurements from Multiple Phase Centers.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bickel, Douglas L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    Ground Moving Target Indicator (GMTI) radar attempts to detect and locate targets with unknown motion. Very slow-moving targets are difficult to locate in the presence of surrounding clutter. This necessitates multiple antenna phase centers (or equivalent) to offer independent Direction of Arrival (DOA) measurements. DOA accuracy and precision generally remains dependent on target Signal-to-Noise Ratio (SNR), Clutter-toNoise Ratio (CNR), scene topography, interfering signals, and a number of antenna parameters. This is true even for adaptive techniques like Space-Time-AdaptiveProcessing (STAP) algorithms.

  4. Directed energy deflection laboratory measurements of common space based targets

    Science.gov (United States)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  5. Direct measurement of friction of a fluctuating contact line.

    Science.gov (United States)

    Guo, Shuo; Gao, Min; Xiong, Xiaomin; Wang, Yong Jian; Wang, Xiaoping; Sheng, Ping; Tong, Penger

    2013-07-12

    We report a direct measurement of the friction coefficient of a fluctuating (and slipping) contact line using a thin vertical glass fiber of diameter d with one end glued onto a cantilever beam and the other end touching a liquid-air interface. By measuring the broadening of the resonant peak of the cantilever system with varying liquid viscosity η, we find the friction coefficient of the contact line has a universal form, ξ(c)≃0.8πdη, independent of the liquid-solid contact angle. The obtained scaling law is further supported by the numerical simulation based on the phase field model under the generalized Navier boundary conditions.

  6. Hadron shower profile and direction measurements in a segmented calorimeter

    International Nuclear Information System (INIS)

    Auchincloss, P.; Blair, R.; Haber, C.

    1982-01-01

    Recently a test measurement was made to see how well the direction of the shower induced by neutrino interactions could be determined in the lab-E detector at Fermilab. While the calorimeter in lab-E has very coarse sampling compared to the detectors described at this workshop, the method used to sample the shower could be employed in other more finely segmented detectors. The shower angle resolution obtained (36 mr.FWHM) is largely constrained by the sampling. In this test pulse heights in 2mm. steps across the hadron shower at five points along the shower were recorded. This was done with 20 wires and 20 fast ADC's. A standard MWPC system intended to accomplish the same task would have required about 250 wires and 250 ADC channels. This considerable saving in system complexity should be possible for any system where finely segmented pulse height measurements are required

  7. A Direct Measurement of the $W$ Decay Width

    Energy Technology Data Exchange (ETDEWEB)

    Vine, Troy [Univ. of College, London (United Kingdom)

    2008-08-01

    A direct measurement of the W boson total decay width is presented in proton-antiproton collisions at √s = 1.96 TeV using data collected by the CDF II detector. The measurement is made by fitting a simulated signal to the tail of the transverse mass distribution in the electron and muon decay channels. An integrated luminosity of 350 pb-1 is used, collected between February 2002 and August 2004. Combining the results from the separate decay channels gives the decay width as 2.038 ± 0.072 GeV in agreement with the theoretical prediction of 2.093 ± 0.002 GeV. A system is presented for the management of detector calibrations using a relational database schema. A description of the implementation and monitoring of a procedure to provide general users with a simple interface to the complete set of calibrations is also given.

  8. A review of direct experimental measurements of detachment

    Science.gov (United States)

    Boedo, J.; McLean, A. G.; Rudakov, D. L.; Watkins, J. G.

    2018-04-01

    Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. We review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson scattering in the divertor region and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.

  9. Zener diode controls switching of large direct currents

    Science.gov (United States)

    1965-01-01

    High-current zener diode is connected in series with the positive input terminal of a dc supply to block the flow of direct current until a high-frequency control signal is applied across the zener diode. This circuit controls the switching of large dc signals.

  10. National policy measures. Right approach to foreign direct investment flows

    Directory of Open Access Journals (Sweden)

    Cătălin-Emilian HUIDUMAC-PETRESCU

    2013-02-01

    Full Text Available 2011 was a difficult year for all the countries, developed and emerging ones. For overcoming the negative effects of the financial crisis, many economies have established as purpose to adopt new economic policies regarding the foreign direct investment flows (FDI, even to stimulate the flows or to reduce it (protectionism measures. So, there can be identified two categories of national policies: measures for the FDI flows stimulation and measures whose aim was the weighting of FDI developing, through restriction and regulation. In the first category we could include the liberalization measures and promotional and faciletation policies. In this study we evidenced that the fundament of the second category of policies is the belief that the FDI outward lead to job exports, to a raise of unemployment and a weakness of the industrial base.Many reports on FDI flows, here we talk about those made by UNCTAD, show that the regulation and restriction policies are seen as a possible protectionism, especially in the agricultural and extractive industries, where there have been required nationalization processes and divestments. Even more, the economies which adopted this kind of policies have been less interested in investing abroad, the outward of FDI being affected and globally the total outward decreased.

  11. Resistivity measurements using a direct current induction method (1963)

    International Nuclear Information System (INIS)

    Delaplace, J.; Hillairet, J.

    1964-01-01

    The conventional methods for measuring electrical resistivities necessitate the fixing of electrical contacts on the sample either mechanically or by soldering. Furthermore it is also necessary to carry,out the measurements on low cross-section samples which are not always easy to obtain. Our direct-current induction method on the other hand requires no contacts and can easily be applied to samples of large cross-section. The sample is placed in a uniform magnetic field; at the moment when the current is cut, eddy currents appear in the sample which tend to oppose the disappearance of the field. The way in which the magnetic flux decreases in the sample makes it possible to determine the resistivity of the material. This method has been applied to samples having diameters of between 1 and 30 mm in the case of metals which are good conductors. It gives a value for the local resistivity and makes it possible to detect any variation along a sample. The measurements can be carried out at all temperature from a few degrees absolute to 500 deg. C. We have used the induction method to follow the purification of beryllium by zone-melting; it is in effect possible to estimate the purity of a material by resistivity measurements. We have measured the resistivity along each bar treated by the zone-melting technique and have thus, localised the purest section. High temperature measurements have been carried out on uranium carbide and on iron-aluminium alloys. This method constitutes an interesting means of investigation the resistivity of solid materials. Its accuracy and rapidity make it particularly adapted both to fundamental research and to production control. (authors) [fr

  12. Direct measurement of Lorentz transformation with Doppler effects

    Science.gov (United States)

    Chen, Shao-Guang

    For space science and astronomy the fundamentality of one-way velocity of light (OWVL) is selfevident. The measurement of OWVL (distance/interval) and the clock synchronization with light-signal transfer make a logical circulation. This means that OWVL could not be directly measured but only come indirectly from astronomical method (Romer's Io eclipse and Bradley's sidereal aberration), furthermore, the light-year by definitional OWVL and the trigonometry distance with AU are also un-measurable. For to solve this problem two methods of clock synchronization were proposed: The direct method is that at one end of dual-speed transmissionline with single clock measure the arriving-time difference of longitudinal wave and transverse wave or ordinary light and extraordinary light, again to calculate the collective sending-time of two wave with Yang's /shear elastic-modulus ratio (E/k) or extraordinary/ordinary light refractive-index ratio (ne/no), which work as one earthquake-station with single clock measures first-shake time and the distance to epicenter; The indirect method is that the one-way wavelength l is measured by dual-counters Ca and Cb and computer's real-time operation of reading difference (Nb - Na) of two counters, the frequency f is also simultaneously measured, then l f is just OWVL. Therefore, with classical Newtonian mechanics and ether wave optics, OWVL can be measured in the Galileo coordinate system with an isotropic length unit (1889 international meter definition). Without any hypotheses special relativity can entirely establish on the metrical results. When a certain wavelength l is defined as length unit, foregoing measurement of one-way wavelength l will become as the measurement of rod's length. Let a rigidity-rod connecting Ca and Cb moves relative to lamp-house with velocity v, rod's length L = (Nb - Na) l will change follow v by known Doppler effect, i.e., L(q) =L0 (1+ (v/c) cos q), where L0 is the proper length when v= 0, v• r = v cos q

  13. Dust grain characterization — Direct measurement of light scattering

    Science.gov (United States)

    BartoÅ, P.; Pavlů, J.

    2018-01-01

    Dust grains play a key role in dusty plasma since they interact with the plasma we can use them to study plasma itself. The grains are illuminated by visible light (e.g., a laser sheet) and the situation is captured with camera. Despite of simplicity, light scattering on similar-to-wavelength sized grains is complex phenomenon. Interaction of the electromagnetic wave with material has to be computed with respect to Maxwell equations — analytic solution is nowadays available only for several selected shapes like sphere, coated sphere, or infinite cylinder. Moreover, material constants needed for computations are usually unknown. For computation result verification and material constant determination, we designed and developed a device directly measur­ing light scattering profiles. Single dust grains are trapped in the ultrasonic field (so called "acoustic levitation") and illuminated by the laser beam. Scattered light is then measured by a photodiode mounted on rotating platform. Synchronous detection is employed for a noise reduction. This setup brings several benefits against conventional methods: (1) it works in the free air, (2) the measured grain is captured for a long time, and (3) the grain could be of arbitrary shape.

  14. Discoveries from Revisiting Apollo Direct Active Measurements of Lunar Dust

    Science.gov (United States)

    O'Brien, Brian

    2010-05-01

    New missions to the moon being developed by China, Japan, India, USA, Russia and Europe and possibilities of human missions about 2020 face the reality that 6 Apollo expeditions did not totally manage or mitigate effects of easily-mobilised and very "sticky" lunar dust on humans and hardware. Laboratory and theoretical modelling cannot reliably simulate the complex lunar environments that affect dynamical movements of lunar dust. The only direct active measurements of lunar dust during Apollo were made by matchbox-sized minimalist Dust Detector Experiments (DDEs) deployed to transmit some 30 million digital measurements from Apollo 11, 12, 14 and 15. These were misplaced or relatively ignored until 2009, when a self-funded suite of discoveries (O'Brien Geophys. Research Letters FIX 6 May 2099) revealed unexpected properties of lunar dust, such as the adhesive force being stronger as illumination increased. We give the first reports of contrasting effects, contamination or cleansing, from rocket exhausts of Apollo 11, 12, 14 and 15 Lunar Modules leaving the moon. We further strengthen the importance of collateral dust inadvertently splashed on Apollo hardware by human activities. Dust management designs and mission plans require optimum use of such in situ measurements, extended by laboratory simulations and theoretical modelling.

  15. Direct measurement of VOC diffusivities in tree tissues

    DEFF Research Database (Denmark)

    Baduru, K.K.; Trapp, Stefan; Burken, Joel G.

    2008-01-01

    Recent discoveries in the phytoremediation of volatile organic compounds (VOCs) show that vapor-phase transport into roots leads to VOC removal from the vadose zone and diffusion and volatilization out of plants is an important fate following uptake. Volatilization to the atmosphere constitutes one...... in numerous vegetation−VOC interactions, including the phytoremediation of soil vapors and dissolved aqueous-phase contaminants. The diffusion of VOCs through freshly excised tree tissue was directly measured for common groundwater contaminants, chlorinated compounds such as trichloroethylene, perchloroethene......, and tetrachloroethane and aromatic hydrocarbons such as benzene, toluene, and methyl tert-butyl ether. All compounds tested are currently being treated at full scale with tree-based phytoremediation. Diffusivities were determined by modeling the diffusive transport data with a one-dimensional diffusive flux model...

  16. Direct electronic measurement of Peltier cooling and heating in graphene.

    Science.gov (United States)

    Vera-Marun, I J; van den Berg, J J; Dejene, F K; van Wees, B J

    2016-05-10

    Thermoelectric effects allow the generation of electrical power from waste heat and the electrical control of cooling and heating. Remarkably, these effects are also highly sensitive to the asymmetry in the density of states around the Fermi energy and can therefore be exploited as probes of distortions in the electronic structure at the nanoscale. Here we consider two-dimensional graphene as an excellent nanoscale carbon material for exploring the interaction between electronic and thermal transport phenomena, by presenting a direct and quantitative measurement of the Peltier component to electronic cooling and heating in graphene. Thanks to an architecture including nanoscale thermometers, we detected Peltier component modulation of up to 15 mK for currents of 20 μA at room temperature and observed a full reversal between Peltier cooling and heating for electron and hole regimes. This fundamental thermodynamic property is a complementary tool for the study of nanoscale thermoelectric transport in two-dimensional materials.

  17. Towards a direct measurement of vacuum magnetic birefringence: PVLAS achievements

    Science.gov (United States)

    Della Valle, F.; Di Domenico, G.; Gastaldi, U.; Milotti, E.; Pengo, R.; Ruoso, G.; Zavattini, G.

    2010-11-01

    Nonlinear effects in vacuum have been predicted but never observed yet directly. The PVLAS collaboration has long been working on an apparatus aimed at detecting such effects by measuring vacuum magnetic birefringence. Unfortunately the sensitivity has been affected by unaccounted noise and systematics since the beginning. A new small prototype ellipsometer has been designed and characterized at the Department of Physics of the University of Ferrara, Italy entirely mounted on a single seismically isolated optical bench. With a finesse F = 414,000 and a cavity length L = 0.5 m we have reached the sensitivity of ψ=2ṡ101/√{Hz} given the laser power at the output of the ellipsometer of P = 24 mW. This record result, very close to the predicted limit, demonstrates the feasibility of reaching such sensitivities, and opens the way to designing a dedicated apparatus for a first detection of vacuum magnetic birefringence.

  18. Quantum analysis of the direct measurement of light waves

    International Nuclear Information System (INIS)

    Saldanha, Pablo L

    2014-01-01

    In a beautiful experiment performed about a decade ago, Goulielmakis et al (2004 Science 305 1267–69) made a direct measurement of the electric field of light waves. However, they used a laser source to produce the light field, whose quantum state has a null expectation value for the electric field operator, so how was it possible to measure this electric field? Here we present a quantum treatment for the f:2f interferometer used to calibrate the carrier–envelope phase of the light pulses in the experiment. We show how the special nonlinear features of the f:2f interferometer can change the quantum state of the electromagnetic field inside the laser cavity to a state with a definite oscillating electric field, explaining how the ‘classical’ electromagnetic field emerges in the experiment. We discuss that this experiment was, to our knowledge, the first demonstration of an absolute coherent superposition of different photon number states in the optical regime. (paper)

  19. Direct measurements of the lifetime of medium-heavy hypernuclei

    Science.gov (United States)

    Qiu, X.; Tang, L.; Chen, C.; Margaryan, A.; Wood, S. A.; Achenbach, P.; Ahmidouch, A.; Albayrak, I.; Androic, D.; Asaturyan, A.; Asaturyan, R.; Ates, O.; Badui, R.; Baturin, P.; Boeglin, W.; Bono, J.; Brash, E.; Carter, P.; Chen, X.; Chiba, A.; Christy, M. E.; Dalton, M. M.; Danagoulian, S.; De Leo, R.; Doi, D.; Elaasar, M.; Ent, R.; Fenker, H.; Fujii, Y.; Furic, M.; Gabrielyan, M.; Gan, L.; Garibaldi, F.; Gaskell, D.; Gasparian, A.; Gogami, T.; Hashimoto, O.; Horn, T.; Hu, B.; Hungerford, Ed V.; Jones, M.; Kanda, H.; Kaneta, M.; Kawama, D.; Khanal, H.; Kohl, M.; Liyanage, A.; Luo, W.; Maeda, K.; Markowitz, P.; Marikyan, G.; Maruta, T.; Matsumura, A.; Maxwell, V.; Mkrtchyan, A.; Mkrtchyan, H.; Nagao, S.; Nakamura, S. N.; Narayan, A.; Neville, C.; Niculescu, G.; Niculescu, M. I.; Nunez, A.; Nuruzzaman; Okayasu, Y.; Petkovic, T.; Pochodzalla, J.; Reinhold, J.; Rodriguez, V. M.; Samanta, C.; Sawatzky, B.; Seva, T.; Shichijo, A.; Tadevosyan, V.; Taniya, N.; Tsukada, K.; Veilleux, M.; Vulcan, W.; Wesselmann, F. R.; Yamamoto, T.; Ye, Z.; Yokota, K.; Yuan, L.; Zhamkochyan, S.; Zhu, L.; HKS (JLab E02-017) Collaboration

    2018-05-01

    The lifetime of a Λ particle embedded in a nucleus (hypernucleus) decreases from that of free Λ decay mainly due to the opening of the ΛN → NN weak decay channel. However, it is generally believed that the lifetime of a hypernucleus attains a constant value (saturation) for medium to heavy hypernuclear masses, yet this hypothesis has been difficult to verify. This paper presents a direct measurement of the lifetime of medium-heavy hypernuclei that were hyper-fragments produced by fission or break-up from heavy hypernuclei initially produced with a 2.34 GeV photon-beam incident on thin Fe, Cu, Ag, and Bi target foils. For each event, fragments were detected in coincident pairs by a low-pressure multi-wire proportional chamber system. The lifetime was extracted from decay time spectrum formed by the difference of the time zeros between the pairs. The measured lifetime from each target is actually a statistical average over a range of mass with mean about 1/2 of the target mass and appears to be a constant of about 200 ps. Although this result cannot exclude unexpected shorter or longer lifetimes for some specific hypernuclei or hypernuclear states, it shows that a systematic decrease in lifetime as hypernuclear mass increases is not a general feature for hypernuclei with mean mass up to A ≈ 130. On the other hand, the success of this experiment and its technique shows that the time delayed fissions observed and used by all the lifetime measurements done so far on heavy hypernuclei could likely have originated from hyper-fragments lighter than the assumed masses.

  20. Parent-child relationship of directly measured physical activity

    Directory of Open Access Journals (Sweden)

    Mâsse Louise C

    2011-03-01

    Full Text Available Abstract Background Studies on parent-child correlations of physical activity have been mixed. Few studies have examined concurrent temporal patterns of physical activity and sedentary behaviors in parents and children using direct measures. The purpose of this study was to examine parent-child activity correlations by gender, day of week, and time of day, using accelerometers - a method for direct assessment of physical activity. Methods Accelerometers were used to assess physical activity and sedentary time in 45 fathers, 45 mothers and their children (23 boys, 22 girls, mean age 9.9 years over the course of 4 days (Thursday - Sunday. Participants were instructed to wear accelerometers for 24 hours per day. Data from accelerometers were aggregated into waking hours on weekdays and weekends (6:00 am to midnight and weekday after-school hours (3:00 - 7:00 pm. Results Across the 4 days, the mean minutes per day of moderate-to-vigorous physical activity (MVPA for fathers was 30.0 (s.d. = 17.3, for mothers was 30.1 (s.d. = 20.1 and for children was 145.47 (s.d. = 51.64. Mothers' and fathers' minutes of MVPA and minutes of sedentary time were positively correlated with child physical activity and sedentary time (all ps Conclusions Greater parental MVPA was associated with increased child MVPA. In addition, having two parents with higher levels of MVPA was associated with greater levels of activity in children. Sedentary time in children was not as strongly correlated with that of their parents. Findings lend support to the notion that to increase childhood activity levels it may be fruitful to improve physical activity among parents.

  1. Measurements of direct CP violation in charm decays at LHCb

    CERN Document Server

    INSPIRE-00257861

    2013-01-01

    Two searches for direct CP violation in D 0 ! h h + (where h = K or ) are presented using data corresponding to an integrated luminosity of 1.0 fb 1 collected in 2011 by LHCb in pp collisions at a centre-of-mass energy of 7 TeV. One analysis uses D 0 mesons produced via a D resonance and the other analysis uses D 0 mesons originating from semileptonic b - decays. In the rst case the avour is tagged by the charge of the accompanying pion and in the latter by the muon charge. The dierence of the CP -violating asymmetries ( A CP = A CP ( K K + ) A CP ( + )) in the two decay channels is measured to be A CP (muon tagged) = (0 : 49 0 : 30 (stat) 0 : 14 (syst))% ; A CP (pion tagged) = ( 0 : 35 0 : 15 (stat) 0 : 10 (syst))% ; A CP (LHCb) = ( 0 : 15 0 : 16)% : These results do not conrm evidence for CP violation in the charm sector

  2. Measured and projected performance of plasma direct converters

    International Nuclear Information System (INIS)

    Barr, W.L.; Moir, R.W.

    1981-01-01

    Test results from two plasma direct converters and their predicted cost and performance on tandem mirror fusion reactors are present. The tests were done at high power density (approx. 70 W/cm 2 ) in steady state to simulate the predicted conditions in a reactor. A single stage unit and a two-stage unit of the Venetian blind type were tested at up to 100 kV and 6 kW for a total time of about 80 hours. Measured efficiencies, when projected to a reactor, are typically about 50% for a single stage unit and 60 to 70% for a two-stage unit, depending on the energy distribution of the ions, the degree of subdivision of the collectors, and on the gas pressure. The high ambipolar potential in tandem mirror devices makes this good efficiency possible. When radiatively cooled grids are used, the incident power density is limited to about 100 W/cm 2 by the thermionic emission of electrons

  3. Direct methods for measuring radionuclides in the human body

    International Nuclear Information System (INIS)

    1996-01-01

    Occupational exposure leading to intakes of internally incorporated radionuclides can occur as a result of various activities. This includes work associated with the different stages of the nuclear fuel cycle, the use of radioactive sources in medicine, scientific research, agriculture and industry, and occupations which involve exposure to enhanced levels of naturally occurring radionuclides. In 1987 the IAEA published a Safety Guide on basic principles for occupational radiation monitoring which set forth principles and objectives of a strategy for monitoring exposures of workers. Since drafting of the present Safety Practice commenced, the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) have been issued. On the basis of the principles laid down in the BSS, the 1987 Safety Guide is also being revised, and recommendations on the assessment of the occupational intake of radioactive materials are to be added. The present Safety Practice, which deals with direct measurement of radionuclides in the human body, is the first to be published in this area. Refs, figs, tabs

  4. The possible direct use of satellite radiance measurements by the Atmospheric Radiation Measurement Program

    International Nuclear Information System (INIS)

    1993-03-01

    The Atmospheric Radiation Measurement (ARM) Program is a major research program initiated by the Department of Energy to improve our understanding of radiative and cloud processes critical to predicting the Earth's climate and its changes. Central to this concept is the use of four to six intensively instrumented sites for long-term study and characterization of the processes of interest. The instrumentation suites will include ground-based, high-accuracy radiometers for measuring the short and longwave surface flux, as well as an extensive set of ground-and air-based instrumentation for characterizing the intervening atmospheric column. Satellite-based measurements are expected to play a very important role in providing top-of-the-atmosphere measurements. In this study, we examine the possibility of comparing ARM outputs directly with satellite measurements, thereby ensuring the independence of these two important data sets. Thus we focused on what do satellites really measure and how well do they measure it. On what can we do about the general lack of adequate visible channel calibration. On what is the best way for ARM to obtain near-real-time access to this unprocessed data. And on what is the optimum way for ARM to make use of satellite data

  5. Direct measurements of protein-stabilized gold nanoparticle interactions.

    Science.gov (United States)

    Eichmann, Shannon L; Bevan, Michael A

    2010-09-21

    We report integrated video and total internal reflection microscopy measurements of protein stabilized 110 nm Au nanoparticles confined in 280 nm gaps in physiological media. Measured potential energy profiles display quantitative agreement with Brownian dynamic simulations that include hydrodynamic interactions and camera exposure time and noise effects. Our results demonstrate agreement between measured nonspecific van der Waals and adsorbed protein interactions with theoretical potentials. Confined, lateral nanoparticle diffusivity measurements also display excellent agreement with predictions. These findings provide a basis to interrogate specific biomacromolecular interactions in similar experimental configurations and to design future improved measurement methods.

  6. Development of an instrument for direct ozone production rate measurements: measurement reliability and current limitations

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien

    2018-02-01

    Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument

  7. Toward a direct comparison of field and laboratory goniometer measurements

    NARCIS (Netherlands)

    Dangel, S.; Verstraete, M.; Schopfer, J.; Kneubuehler, M.; Schaepman, M.E.; Itten, K.I.

    2005-01-01

    Field and laboratory goniometers are widely used in the remote sensing community to assess spectrodirectional reflection properties of selected targets. Even when the same target and goniometer system are used, field and laboratory results cannot directly be compared due to inherent differences,

  8. 47 CFR 73.154 - AM directional antenna partial proof of performance measurements.

    Science.gov (United States)

    2010-10-01

    ... available to the FCC upon request. Maps showing new measurement points, i.e., points not measured in the...) Measurement points shall be selected from the points measured in latest full proof of performance provided..., the licensee shall measure directional field strength for comparison to either the directional or the...

  9. Directly acting spring loaded safety valves as shock reducing measure

    International Nuclear Information System (INIS)

    Ismaier, A.; Schluecker, E.

    2010-01-01

    Hydraulic shocks as induced by fast closure of armatures or by sudden pump failures are massive impacts in piping systems and require extensive measures to absorb the generated load. Basically the avoidance of water hammers are preferable but in case of emergency shutdowns unavoidable hydraulic shocks have to be reduced by appropriate measures. The authors describe experiments with spring loaded safety valves as shock reducing measures. It was shown that the vale dimensions is essential for the efficacy. A realistic modeling is possible using the one-dimensional fluid mechanics code ROLAST.

  10. Direct photon measurements by the D OE experiment

    International Nuclear Information System (INIS)

    Abachi, S.

    1996-07-01

    We report a measurement of the cross section for production of isolated photons with transverse energy E T > 12 GeV in the central (absolute value of η -1 . The cross section is compared with a next-to-leading order (NLO) QCD calculation. We also present preliminary measurements of the center of mass scattering angle distribution and of the correlations between the rapidity of the photon and that of the leading jet in the event

  11. Direct Optical Measurement of Vorticity in Fluid Flow

    Science.gov (United States)

    2015-12-11

    Rotational Doppler Effect ( RDE ) and Laguerre-Gaussian (LG) light beams that possess orbital angular momentum (OAM). The approach has been implemented...Analogously, but much less utilized, the Rotational Doppler Effect ( RDE ) can be used to measure the angular velocity of a rotating object [4-5...Measuring with RDE requires the use of Laguerre-Gaussian (LG) light beams that possess orbital angular momentum (OAM) l , a spatial (azimuthal

  12. Some new possibilities in direct visible and x ray measurements

    International Nuclear Information System (INIS)

    Gex, J.P.; Sauneuf, R.; Boutot, J.P.; Delmotte, J.C.

    1979-01-01

    Subnanosecond photodetection measurements in visible and X ray range with vacuum cell and very thin microchannel plate phototube (coupled with a fast scintillator or not) in conjunction with fast oscilloscope (5 GHz) are presented. They are compared to those given by a visible or a gold photocathode X-ray streak camera (temporal resolution better than 20 ps). (author)

  13. Methods for direct measurement of the plasma potential

    DEFF Research Database (Denmark)

    Andersen, S. A.; Christoffersen, G. B.; Jensen, Vagn Orla

    1972-01-01

    Reports on a simple experimental technique which can be used for determination of the plasma where the plasma potential prevails; these ions are accepted by the analyser plate when phi c= phi pl. Part of this technique has been used by Andersen, Jensen, Michelsen and Nielsen (1971) in measurements...

  14. Direct-current proton-beam measurements at Los Alamos

    International Nuclear Information System (INIS)

    Sherman, J.; Stevens, R.R.; Schneider, J.D.; Zaugg, T.

    1994-01-01

    Recently, a CW proton accelerator complex was moved from Chalk River Laboratories (CRL) to Los Alamos National Laboratory. This includes a 50-keV dc proton injector with a single-solenoid low-energy beam transport system (LEBT) and a CW 1.25-MeV, 267-MHz radiofrequency quadrupole (RFQ). The move was completed after CRL had achieved 55-mA CW operation at 1.25 MeV using 250-kW klystrode tubes to power the RFQ. These accelerator components are prototypes for the front end of a CW linac required for an accelerator-driven transmutation linac, and they provide early confirmation of some CW accelerator components. The injector (ion source and LEBT) and emittance measuring unit are installed and operational at Los Alamos. The dc microwave ion source has been operated routinely at 50-keV, 75-mA hydrogen-ion current. This ion source has demonstrated very good discharge and H 2 gas efficiencies, and sufficient reliability to complete CW RFQ measurements at CRL. Proton fraction of 75% has been measured with 550-W discharge power. This high proton fraction removes the need for an analyzing magnet. Proton LEBT emittance measurements completed at Los Alamos suggest that improved transmission through the RFQ may be achieved by increasing the solenoid focusing current. Status of the final CW RFQ operation at CRL and the installation of the RFQ at Los Alamos is given

  15. Prospects for direct measurement of time-integrated Bs mixing

    International Nuclear Information System (INIS)

    Siccama, I.

    1994-01-01

    This note investigates the prospects of measuring time-integrated B s mixing. Three inclusive decay modes of the B s meson are discussed. For each reconstruction mode, the expected number of events and the different background channels are discussed. Estimates are given for the uncertainty on the mixing parameter χ s . (orig.)

  16. New Directions in Mass Communications Research: Physiological Measurement.

    Science.gov (United States)

    Fletcher, James E.

    Psychophysiological research into the effects of mass media, specifically the music of the masses, promises increased insight into the control the media exert on all their consumers. Attention and retention of mass media messages can be tested by measuring the receiver's electrodernal activity, pupil dilation, peripheral vasodilation, and heart…

  17. Direct measurement technique for shock wave velocity with irradiation drive

    International Nuclear Information System (INIS)

    Wang Feng; Peng Xiaoshi; Liu Shenye; Jiang Xiaohua; Ding Yongkun

    2011-01-01

    According to the ionization mechanism of transparent material under super high pressure, the direct diagnosis method of shock wave has been analyzed. With the Drude free electron model, the reflectivity difference of shock wave front under different pressures was analyzed. The blank effect in the detector was studied, which is caused by the X-ray ionization of transparent material, after analyzing the reflectivity data in space-time scale. The experiment shows that the beginning point and duration of blank effect are consistent with the start point and duration of laser pulse, respectively. And the reflectivity of shock wave front is about 35% when the shock velocity is 32 km/s. The reason and solution for blank effect was presented. The formula to calculate the shock wave velocity in transparent material was also deduced and verified. (authors)

  18. The Measure of Human Error: Direct and Indirect Performance Shaping Factors

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Candice D. Griffith; Jeffrey C. Joe

    2007-08-01

    The goal of performance shaping factors (PSFs) is to provide measures to account for human performance. PSFs fall into two categories—direct and indirect measures of human performance. While some PSFs such as “time to complete a task” are directly measurable, other PSFs, such as “fitness for duty,” can only be measured indirectly through other measures and PSFs, such as through fatigue measures. This paper explores the role of direct and indirect measures in human reliability analysis (HRA) and the implications that measurement theory has on analyses and applications using PSFs. The paper concludes with suggestions for maximizing the reliability and validity of PSFs.

  19. Direct measurement of the plasma response to electrostatic ion waves

    International Nuclear Information System (INIS)

    Sarfaty, M.; DeSouza-Machado, S.; Skiff, F.

    1995-01-01

    Plasma wave-wave and wave-particle interactions are studied in a linear magnetized plasma. The relatively quiet plasma is produced by an argon gas-discharge. The plasma density is n e ≅ 10 9 cm -3 and the electron/ion temperatures are T e ≅ 5eV and T i = 0.05eV. A grid and a four ring antenna, both mounted on a scanning carriage, are used to launch electrostatic ion waves in the plasma. Laser Induced Fluorescence measurements of both the linear and the nonlinear plasma response to the wave fields are presented. The Vlasov-Poisson equations are used to explain the measured zero, first and second order terms of the ion distribution function in the presence of wave fields. In addition to the broadening (heating) of the ion distribution as the authors increase the wave amplitudes, induced plasma flows are observed both along and across the magnetic field

  20. Direct measurement of bull's-eye nanoantenna metal loss

    Science.gov (United States)

    Hassani Nia, Iman; Jang, Sung J.; Memis, Omer G.; Gelfand, Ryan; Mohseni, Hooman

    2013-09-01

    The loss in optical antennas can affect their performance for their practical use in many branches of science such as biological and solar cell applications. However the big question is that how much loss is due to the joule heating in the metals. This would affect the efficiency of solar cells and is very important for single photon detection and also for some applications where high heat generation in nanoantennas is desirable, for example, payload release for cancer treatment. There are few groups who have done temperature measurements by methods such as Raman spectroscopy or fluorescence polarization anisotropy. The latter method, which is more reliable than Raman spectroscopy, requires the deposition of fluorescent molecules on the antenna surface. The molecules and the polarization of radiation rotate depending upon the surface temperature. The reported temperature measurement accuracy in this method is about 0.1° C. Here we present a method based on thermo-reflectance that allows better temperature accuracy as well as spatial resolution of 500 nm. Moreover, this method does not require the addition of new materials to the nanoantenna. We present the measured heat dissipation from bull's-eye nanoantennas and compare them with 3D simulation results.

  1. A Scale Elasticity Measure for Directional Distance Function and its Dual

    OpenAIRE

    Valentin Zelenyuk

    2011-01-01

    In this paper we introduce a scale elasticity measure based on directional distance function for multi-output-multi-input technologies and explore its fundamental properties. Specifically, we derive necessary and sufficient condition for equivalence of the scale elasticity measure based on the directional distance function with the input oriented and output oriented scale elasticity measures. We also establish duality relationship between the scale elasticity measure based on the directional ...

  2. Direct measurement of exciton valley coherence in monolayer WSe2

    KAUST Repository

    Hao, Kai

    2016-02-29

    In crystals, energy band extrema in momentum space can be identified by a valley index. The internal quantum degree of freedom associated with valley pseudospin indices can act as a useful information carrier, analogous to electronic charge or spin. Interest in valleytronics has been revived in recent years following the discovery of atomically thin materials such as graphene and transition metal dichalcogenides. However, the valley coherence time—a crucial quantity for valley pseudospin manipulation—is difficult to directly probe. In this work, we use two-dimensional coherent spectroscopy to resonantly generate and detect valley coherence of excitons (Coulomb-bound electron–hole pairs) in monolayer WSe2 (refs ,). The imposed valley coherence persists for approximately one hundred femtoseconds. We propose that the electron–hole exchange interaction provides an important decoherence mechanism in addition to exciton population recombination. This work provides critical insight into the requirements and strategies for optical manipulation of the valley pseudospin for future valleytronics applications.

  3. Directional rf probe for measurement of conductivity of flowing plasmas

    International Nuclear Information System (INIS)

    Jayakumar, R.; Chakravarthy, D.P.; Rohatgi, V.K.

    1977-01-01

    An electrodeless immersible rf probe for measurement of plasma conductivity in the range 0.01 to 100 mho/m has been designed and fabricated. The probe, with an overall diameter of 11 mm, employs unidirectional electromagnetic field lines which reduce the inaccuracies caused by insertion of the probe in a flowing plasma. In the range studied the probe output shows a linear relationship with the conductivity of the medium. Such probes are of interest in the study of MHD and reentry plasmas

  4. Direct measurement of nonlinear properties of bipartite quantum states.

    Science.gov (United States)

    Bovino, Fabio Antonio; Castagnoli, Giuseppe; Ekert, Artur; Horodecki, Paweł; Alves, Carolina Moura; Sergienko, Alexander Vladimir

    2005-12-09

    Nonlinear properties of quantum states, such as entropy or entanglement, quantify important physical resources and are frequently used in quantum-information science. They are usually calculated from a full description of a quantum state, even though they depend only on a small number of parameters that specify the state. Here we extract a nonlocal and a nonlinear quantity, namely, the Renyi entropy, from local measurements on two pairs of polarization-entangled photons. We also introduce a "phase marking" technique which allows the selection of uncorrupted outcomes even with nondeterministic sources of entangled photons. We use our experimental data to demonstrate the violation of entropic inequalities. They are examples of nonlinear entanglement witnesses and their power exceeds all linear tests for quantum entanglement based on all possible Bell-Clauser-Horne-Shimony-Holt inequalities.

  5. Direct measurement of helical cell motion of the spirochete leptospira.

    Science.gov (United States)

    Nakamura, Shuichi; Leshansky, Alexander; Magariyama, Yukio; Namba, Keiichi; Kudo, Seishi

    2014-01-07

    Leptospira are spirochete bacteria distinguished by a short-pitch coiled body and intracellular flagella. Leptospira cells swim in liquid with an asymmetric morphology of the cell body; the anterior end has a long-pitch spiral shape (S-end) and the posterior end is hook-shaped (H-end). Although the S-end and the coiled cell body called the protoplasmic cylinder are thought to be responsible for propulsion together, most observations on the motion mechanism have remained qualitative. In this study, we analyzed the swimming speed and rotation rate of the S-end, protoplasmic cylinder, and H-end of individual Leptospira cells by one-sided dark-field microscopy. At various viscosities of media containing different concentrations of Ficoll, the rotation rate of the S-end and protoplasmic cylinder showed a clear correlation with the swimming speed, suggesting that these two helical parts play a central role in the motion of Leptospira. In contrast, the H-end rotation rate was unstable and showed much less correlation with the swimming speed. Forces produced by the rotation of the S-end and protoplasmic cylinder showed that these two helical parts contribute to propulsion at nearly equal magnitude. Torque generated by each part, also obtained from experimental motion parameters, indicated that the flagellar motor can generate torque >4000 pN nm, twice as large as that of Escherichia coli. Furthermore, the S-end torque was found to show a markedly larger fluctuation than the protoplasmic cylinder torque, suggesting that the unstable H-end rotation might be mechanically related to changes in the S-end rotation rate for torque balance of the entire cell. Variations in torque at the anterior and posterior ends of the Leptospira cell body could be transmitted from one end to the other through the cell body to coordinate the morphological transformations of the two ends for a rapid change in the swimming direction. Copyright © 2014 Biophysical Society. Published by Elsevier Inc

  6. Direct Photon and Neutral Mesons Measurements with the ALICE Detector

    CERN Document Server

    Matyja, Adam

    2016-01-01

    The ALICE experiment at LHC is dedicated to studies of the Quark– Gluon Plasma (QGP) state, which is going to be created in heavy-ion collisions. Both photons and neutral mesons are excellent probes for QGP formation. Photons are produced during the different stages of the expan- sion of the initial hot matter fireball. They do not interact strongly with the medium and passing through it, they carry information on their emis- sion point. The prompt photons which are formed at the early stage of the collision enable us to test perturbative QCD constraining parton distri- butions and fragmentation functions. Looking into the regime of thermal photons, one can extract the temperature of the medium. The medium- induced energy loss of particles can be investigated via the measurement of neutral meson spectra for different centrality classes as well as via neutral meson–hadron correlations. A decrease of the nuclear modification factor ( R AA ) with centrality of the collision is observed. The suppression of th...

  7. Direct and Indirect Measures of Level-2 Perspective-Taking in Children and Adults

    Science.gov (United States)

    Surtees, Andrew D. R.; Butterfill, Stephen A.; Apperly, Ian A.

    2012-01-01

    Studies with infants show divergence between performance on theory of mind tasks depending on whether "direct" or "indirect" measures are used. It has been suggested that direct measures assess a flexible but cognitively demanding ability to reason about the minds of others, whereas indirect measures assess distinct processes…

  8. A Scale Elasticity Measure for Directional Distance Function and its Dual: Theory and DEA Estimation

    OpenAIRE

    Valentin Zelenyuk

    2012-01-01

    In this paper we focus on scale elasticity measure based on directional distance function for multi-output-multi-input technologies, explore its fundamental properties and show its equivalence with the input oriented and output oriented scale elasticity measures. We also establish duality relationship between the scale elasticity measure based on the directional distance function with scale elasticity measure based on the profit function. Finally, we discuss the estimation issues of the scale...

  9. Measurements of integrated direct, diffuse and global ultraviolet-B radiation

    International Nuclear Information System (INIS)

    Utrillas, M.P.; Pedrós, R.; Gandía, S.; Gómez-Amo, J.L.; Estellés, V.; Martínez-Lozano, J.A.

    2015-01-01

    We present the first multiyear set of simultaneous measurements of the global ultraviolet-B radiation and its two components: direct and diffuse. The measurements have been taken with four YES-UVB-1 radiometers: two radiometers to measure the diffuse radiation, one provided with a shadow band and the other with a shadow disk on a Sun tracker; a radiometer to measure the global horizontal radiation; and a Sun-tracking radiometer to measure the direct radiation with an especially designed radiance collimator. The diffuse minute-values measured with both instruments agree within a coefficient correlation of 1.00. The diffuse component represents at least 50% of the global UVB (ultraviolet-B) radiation. The minute values of global UVB irradiance obtained by adding the direct and diffuse components concur with the measured global irradiance. Therefore, the measurement of the direct irradiance enables the estimation of the diffuse component, and gives an insight into the factors that affect its value, especially aerosols. - Highlights: • Simultaneous measurements of global, direct and diffuse UVB (ultraviolet-B) radiation. • The diffuse minute-values are at least 50% of the global ones. • The diffuse measurements are highly correlated to the aerosol load. • The sum of direct + diffuse radiation concur with the measured global.

  10. Measurement of direct currents of under 10-10 ampere and of resistances of 1012 Ω for a direct current

    International Nuclear Information System (INIS)

    Vagner, J.

    1965-01-01

    Measurement of weak direct currents by Townsend's method using a vibrating condenser electrometer. Development of a current generator giving a pico-ampere independently of the resistance of the circuit used. Development of generators giving currents which may be adjusted continuously and exactly (0.1 to 1 pico-ampere, 1 to 10 pico-amperes, 10 to 100 pico-amperes). Measurement of very high resistances (10 12 Ω) by three different methods. Graphs are made by plotting the value of the resistance against the potential difference applied across it (from 50 milli-volts to 50 volts). Two methods use adjustable current generators and the third is applicable to the measurement of resistances of between 10 7 and 10 13 Ω using a series of condensers ranging from 50 pico-farads to 10 micro-farads. The accuracy of the measurements is between 0. 5 and 1 per cent. (author) [fr

  11. Programmes of measures under the water framework directive – a comparative case study

    DEFF Research Database (Denmark)

    Baaner, Lasse

    2011-01-01

    The water framework directive requires programmes of measures composed by the Member States, in order to achieve its environmental objectives. This article examines three programmes of measures for river basins in Denmark, Sweden, and Norway, with a focus on the differences in how the programmes...... direct the authorities’ activities with regard to water management. It concludes that there are major differences in the precision of the measures, the range of legal instruments used, and in the focus on active and direct management of the aquatic environment. The Danish programme seems to facilitate...

  12. Measurements of energy spectra of fast electrons from PF-1000 in the upstream and downstream directions

    Energy Technology Data Exchange (ETDEWEB)

    Kwiatkowski, R.; Czaus, K.; Skladnik-Sadowska, E.; Malinowski, K.; Zebrowski, J. [The Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Sadowski, M.J. [The Andrzej Soltan Institute for Nuclear Studies (IPJ), 05-400 Otwock-Swierk (Poland); Karpinski, L.; Paduch, M.; Scholz, M. [Institute of Plasma Physics and Laser Microfusion (IPPLM), 01-497 Warsaw (Poland); Kubes, P. [Czech Technical University (CVUT), 166-27 Prague, (Czech Republic)

    2011-07-01

    The paper describes measurements of energy spectra of electrons emitted in the upstream direction along the symmetry-axis of the PF-1000 facility, operated with the deuterium filling at 21 kV, 290 kJ. The measurements were performed with a magnetic analyzer. The same analyzer was used to measure also electron beams emitted in along the symmetry-axis in the downstream direction. The recorded spectra showed that the electron-beams emitted in the upstream direction have energies in the range from about 40 keV to about 800 keV, while those in the downstream direction have energies in the range from about 60 keV to about 200 keV. These spectra confirm that in the PF (Plasma Focus) plasma column there appear strong local fields accelerating charged particles in different directions. This document is composed of a paper and a poster. (authors)

  13. Calibration-free absolute frequency response measurement of directly modulated lasers based on additional modulation.

    Science.gov (United States)

    Zhang, Shangjian; Zou, Xinhai; Wang, Heng; Zhang, Yali; Lu, Rongguo; Liu, Yong

    2015-10-15

    A calibration-free electrical method is proposed for measuring the absolute frequency response of directly modulated semiconductor lasers based on additional modulation. The method achieves the electrical domain measurement of the modulation index of directly modulated lasers without the need for correcting the responsivity fluctuation in the photodetection. Moreover, it doubles measuring frequency range by setting a specific frequency relationship between the direct and additional modulation. Both the absolute and relative frequency response of semiconductor lasers are experimentally measured from the electrical spectrum of the twice-modulated optical signal, and the measured results are compared to those obtained with conventional methods to check the consistency. The proposed method provides calibration-free and accurate measurement for high-speed semiconductor lasers with high-resolution electrical spectrum analysis.

  14. An alternative method for the measurement of the mechanical impulse of a vertically directed blast

    CSIR Research Space (South Africa)

    Turner, GR

    2008-01-01

    Full Text Available An alternative method for the measurement of the total mechanical impulse of a vertically directed blast due to an explosive charge is presented. The method differs from apparatus that employ a vertically displaced mass (similar in principle...

  15. X mapping in man: evidence against direct measurable linkage between ocular albinism and deutan colour blindness.

    Science.gov (United States)

    Pearce, W G; Sanger, R

    1976-01-01

    A Newfoundland kindred in which ocular albinism and deutan colour blindness are segregating provides strong evidence against the loci for these two X-borne characters being within direct measurable distance of each other. PMID:1085370

  16. Directional spectrum of ocean waves from array measurements using phase/time/path difference methods

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A.; Sarma, Y.V.B.; Menon, H.B.

    Wave direction has for the first time been consistently, accurately and unambiguously evaluated from array measurements using the phase/time/path difference (PTPD) methods of Esteva in case of polygonal arrays and Borgman in case of linear arrays...

  17. Direct measurement of the centre of mass location in walking persons

    African Journals Online (AJOL)

    h-1 on a motorised treadmill are presented. These data are the first direct measurements of COM oscillation in walking humans over an entire stride. Data found using other, less direct methods are not dissimilar to the data obtained for COM ...

  18. Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

    Energy Technology Data Exchange (ETDEWEB)

    Kreim, Susanne Waltraud

    2009-08-25

    This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i.e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10{sup -7}. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range. (orig.)

  19. Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

    International Nuclear Information System (INIS)

    Kreim, Susanne Waltraud

    2009-01-01

    This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i.e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10 -7 . The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range. (orig.)

  20. Use of Direct Current Resistivity Measurements to Assess AISI 304 Austenitic Stainless Steel Sensitization

    OpenAIRE

    Mesquita, Ramaiany Carneiro; Mecury, José Manoel Rivas; Tanaka, Auro Atsumi; Sousa, Regina Célia de

    2015-01-01

    This paper describes the feasibility of using direct current electrical resistivity measurements to evaluate AISI 304 austenitic stainless steel sensitization. ASTM A262 – Practice A and double loop electrochemical potentiodynamic reactivation (DL-EPR) tests were performed to assess the degree of sensitization (DoS) qualitatively and quantitatively, and electrical resistivity (ER) was measured by the four-point direct-current potential drop method. The results indicate that the DoS incr...

  1. A new device for production measurements of field integral and field direction of SC dipole magnets

    International Nuclear Information System (INIS)

    Preissner, H.; Bouchard, R.; Luethke, P.; Makulski, A.; Meinke, R.; Nesteruk, K.

    1990-01-01

    The performance of all superconducting magnets for HERA is tested in the DESY magnet test facility and their magnetic field is measured. For dipole magnets the magnitude and the direction of the field is measured point by point along the axis with a mole-type probe which is transported through the beam pipe. The positioning of the probe is done via a toothed belt with an accuracy of 1 mm. The probe houses two Hall probes perpendicular to each other, a gravitational tilt sensor and an NMR probe. The field in the plateau is measured by NMR, the fringe field is measured by the Hall probes and the field direction relative to gravity is obtained from the ratio of the two Hall voltages and the tilt sensor. The field integral is determined with an accuracy of 10 -4 and the average field direction is measured with an accuracy of 0.2 mrad. 4 refs., 4 figs

  2. Estimations of On-site Directional Wave Spectra from Measured Ship Responses

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2006-01-01

    include an quivalence of energy in the governing equations and, as regards the parametric concept, a frequency dependent spreading of the waves is introduced. The paper includes an extensive analysis of full-scale measurements for which the directional wave spectra are estimated by the two ship response......In general, two main concepts can be applied to estimate the on-site directional wave spectrum on the basis of ship response measurements: 1) a parametric method which assumes the wave spectrum to be composed by parameterised wave spectra, or 2) a non-parametric method where the directional wave...

  3. Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Kenichi; Okamoto, Atsushi [Graduate School of Science, Nagoya Univ., Nagoya (Japan); Yoshimura, Shinji; Tanaka, Masayoshi Y. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2000-07-01

    It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

  4. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  5. Wind gust measurements using pulsed Doppler wind-lidar: comparison of direct and indirect techniques

    DEFF Research Database (Denmark)

    The measurements of wind gusts, defined as short duration wind speed maxima, have traditionally been limited by the height that can be reached by weather masts. Doppler lidars can potentially provide information from levels above this and thereby fill this gap in our knowledge. To measure the 3D...... is 3.9 s) which can provide high resolution turbulent measurements, both in the vertical direction, and potentially in the horizontal direction. In this study we explore different strategies of wind lidar measurements to measure the wind speed maxima. We use a novel stochastic turbulence reconstruction...... model, driven by the Doppler lidar measurements, which uses a non-linear particle filter to estimate the small-scale turbulent fluctuations. The first results show that the reconstruction method can reproduce the wind speed maxima measured by the sonic anemometer if a low-pass filter with a cut...

  6. γ-γ directional angular correlations measurements for transitions in 140 Ce

    International Nuclear Information System (INIS)

    Zamboni, C.B.; Lapolli, A.L.; Silva Figueira, M.C. da; Yoneama, M.L.; Dias, J.F.; Medeiros, J.A.G. de.

    1990-01-01

    The directional correlations of coincident gamma transitions have been measured in 140 Ce following the β - decay of 140 La, with T 1/2 = 40,3 hs, using a spectrometer consisting of two Ge detectors. The measurements were carried out for 8 gamma cascades and the multipole mixing ratios, δ, for the majority gamma transitions were extracted from the present results. (author)

  7. Measurements of ionospheric TEC in the direction of GPS satellites and comparison with three ionospheric models

    Directory of Open Access Journals (Sweden)

    E. Zuccheretti

    1997-06-01

    Full Text Available The IEN Galileo Ferraris uses GPS for time and frequency synchronization. To obtain high performance it is important to reduce the error due to the ionospheric time-delay in GPS measurements. Evaluations of TEC in the direction of GPS satellites, obtained from three different ionospheric models, have been compared with corresponding measurements by GPS signal.

  8. Comparing Direct versus Indirect Measures of the Pedagogical Effectiveness of Team Testing

    Science.gov (United States)

    Bacon, Donald R.

    2011-01-01

    Direct measures (tests) of the pedagogical effectiveness of team testing and indirect measures (student surveys) of pedagogical effectiveness of team testing were collected in several sections of an undergraduate marketing course with varying levels of the use of team testing. The results indicate that although students perceived team testing to…

  9. Measuring and explaining multi-directional inefficiency in the Malaysian dairy industry

    NARCIS (Netherlands)

    Mohd Suhaimi, Nurul Aisyah Binti; Mey, de Yann; Oude Lansink, Alfons

    2017-01-01

    Purpose: The purpose of this paper is to measure the technical inefficiency of dairy farms and subsequently investigate the factors affecting technical inefficiency in the Malaysian dairy industry. Design/methodology/approach: This study uses multi-directional efficiency analysis to measure the

  10. Measurement of spin motions in a storage ring outside the stable polarization direction

    International Nuclear Information System (INIS)

    Akchurin, N.; Badano, L.; Bravar, A.; Istituto Nazionale di Fisica Nucleare, Legnaro

    1993-06-01

    Polarized, stored beams are becoming a more and more important tool in nuclear and high energy physics. In order to measure the beam polarization in a storage ring the polarization vector of the stored beams has to aim, revolution for revolution, over a period of seconds to minutes, into the same, so-called ''stable'' direction. In this paper measurements at the Indiana University cooler ring (IUCF) are described in which for the first time in a storage ring oscillations of the polarization vector around this stable direction have been measured. The existence and the dynamics of such oscillations are, for instance, important for a new proposed technique for polarizing stored hadron beams

  11. Direct optical measurement of light coupling into planar waveguide by plasmonic nanoparticles.

    Science.gov (United States)

    Pennanen, Antti M; Toppari, J Jussi

    2013-01-14

    Coupling of light into a thin layer of high refractive index material by plasmonic nanoparticles has been widely studied for application in photovoltaic devices, such as thin-film solar cells. In numerous studies this coupling has been investigated through measurement of e.g. quantum efficiency or photocurrent enhancement. Here we present a direct optical measurement of light coupling into a waveguide by plasmonic nanoparticles. We investigate the coupling efficiency into the guided modes within the waveguide by illuminating the surface of a sample, consisting of a glass slide coated with a high refractive index planar waveguide and plasmonic nanoparticles, while directly measuring the intensity of the light emitted out of the waveguide edge. These experiments were complemented by transmittance and reflectance measurements. We show that the light coupling is strongly affected by thin-film interference, localized surface plasmon resonances of the nanoparticles and the illumination direction (front or rear).

  12. Directional anisotropy in thermal infrared measurements over Toulouse city centre during the CAPITOUL measurement campaigns: first results

    Science.gov (United States)

    Lagouarde, J.-P.; Irvine, M.

    2008-12-01

    The measurements of surface temperature are prone to important directional anisotropy related to the structure of the canopy and the radiative and energy exchanges inside of it. Directional effects must be taken into account for a number of practical applications such as the correction of large swath satellite data, the assimilation of thermal infrared (TIR) measurements in surface models, the design of future spatial missions… For urban canopies, experimental measurements of TIR directional anisotropy previously performed during summer days over Marseille in the framework of the ESCOMPTE campaign (2001) revealed significant angular surface temperature variations with noticeable hot spot effects whose intensity was related to the canopy structure. The CAPITOUL project ( http://medias.cnrs.fr/capitoul/ ) provided the opportunity to extend these results to other seasons and to nighttime conditions. The experimental setup is based on the use of 2 airborne TIR cameras with different lenses, inclination and resolution, and installed aboard a small aircraft. The flight protocol allowed the retrieval of directional anisotropy in all azimutal directions and in a range of zenith viewing angles between nadir and 62°. Measurements were performed during several intensive operation periods (IOP) in summer (2004 july), autumn (2004 September and October) and winter (2005 February). Only the first results of the 2004 autumn and 2005 winter IOPs are presented in this paper. The results obtained in daytime conditions confirm the systematic hot spot effects observed in previous experiments over cities. The variations found seem to be particularly important in winter when sun elevation is low: for instance they range between -4 and 10 K between oblique and nadir viewing in February. During nighttime conditions, angular variations are much lower (always less than 2 K between nadir and 60° zenithal viewing angle), whichever the azimutal viewing direction.

  13. Should direct measurements of tumor oxygenation relate to the radiobiological hypoxic fraction of a tumor?

    International Nuclear Information System (INIS)

    Fenton, Bruce M.; Kiani, Mohammad F.; Siemann, Dietmar W.

    1995-01-01

    Purpose: Numerous previous studies have attempted to relate the radiobiological hypoxic fraction (HF) to direct measures of tumor oxygenation such as HbO 2 saturations, tumor pO 2 levels, or hypoxic cell labeling. Although correlations have been found within tumor lines, no overall relationships were seen across tumor lines. The current objective was to examine the effect on HF of changes in the fractions of the oxygenated and anoxic tumor cells that remain clonogenic. Methods and Materials: A mathematical model was developed that relates the HF to direct measures of tumor oxygenation. The primary assumptions were that: (a) the tumor is divided into distinct compartments of either fully oxygenated or fully anoxic cells, and (b) the survival of the oxygenated cells is negligible compared to that of the anoxic cells. Based on these assumptions, the HF is plotted as a function of the fractions of clonogenic or nonclonogenic, and oxygenated or anoxic cells. Results: If all cells are clonogenic, then the HF equals the fraction of anoxic cells. If a higher fraction of anoxic than oxygenated cells are nonclonogenic, then the HF will be overestimated by the fraction of the tumor measured to be anoxic using direct measuring techniques. If a higher fraction of the oxygenated than anoxic cells are nonclonogenic, the HF will be underestimated by the fraction of anoxic cells. Conclusion: Correlations between the HF and direct measures of tumor oxygenation have been described within tumor lines evaluated under different physiological condition. However, such relationships can be totally unpredictable between different tumors if the fraction of the anoxic cells that is clonogenic varies substantially. Clearly, if tumor anoxia cannot be detected using direct measures, this is an accurate indication that the tumor is well oxygenated. When tumor anoxia is present, however, the conclusions are ambiguous. Even when a small fraction of the tumor is measured as anoxic, direct measures

  14. The agreement between parent-reported and directly measured child language and parenting behaviors

    Directory of Open Access Journals (Sweden)

    Shannon K Bennetts

    2016-11-01

    Full Text Available Parenting behaviors are commonly targeted in early interventions to improve children’s language development. Accurate measurement of both parenting behaviors and children’s language outcomes is thus crucial for sensitive assessment of intervention outcomes. To date, only a small number of studies have compared parent-reported and directly measured behaviors, and these have been hampered by small sample sizes and inaccurate statistical techniques, such as correlations. The Bland-Altman Method and Reduced Major Axis regression represent more reliable alternatives because they allow us to quantify fixed and proportional bias between measures. In this study, we draw on data from two Australian early childhood cohorts (N= 201 parents and slow-to-talk toddlers aged 24 months; and N=218 parents and children aged 6-36 months experiencing social adversity to (1 examine agreement and quantify bias between parent-reported and direct measures, and (2 to determine socio-demographic predictors of the differences between parent-reported and direct measures. Measures of child language and parenting behaviors were collected from parents and their children. Our findings support the utility of the Bland-Altman Method and Reduced Major Axis regression in comparing measurement methods. Results indicated stronger agreement between parent-reported and directly measured child language, and poorer agreement between measures of parenting behaviors. Child age was associated with difference scores for child language; however the direction varied for each cohort. Parents who rated their child’s temperament as more difficult tended to report lower language scores on the parent questionnaire, compared to the directly measured scores. Older parents tended to report lower parenting responsiveness on the parent questionnaire, compared to directly measured scores. Finally, speaking a language other than English was associated with less responsive parenting behaviors on the

  15. Direct measurement of the beam deflection angle using the axial B-dot field

    Directory of Open Access Journals (Sweden)

    Xiaozhong He

    2011-05-01

    Full Text Available Beam position monitors are an important diagnostics tool for particle accelerator operation and related beam dynamics research. The measurement of the beam deflection angle, or moving direction of a charged particle beam with respect to the beam pipe axis, can provide useful additional information. Beam monitors sensitive to the beam’s azimuthal B-dot field (sometimes referred as B dots are used to measure the displacement (position of the beam centroid, as the beam generates a dipole term of the azimuthal magnetic field. Similarly, a dipole term of the axial magnetic field will be generated by the beam moving in a direction not parallel to the axis of the beam pipe. In this paper, a new method using the axial B-dot field is presented to measure the beam deflection angle directly, including the theoretical background. Simulations using the MAFIA numerical code have been performed, demonstrating a good agreement to the new established analytical model.

  16. Measurement of acoustic characteristics of Japanese Buddhist temples in relation to sound source location and direction.

    Science.gov (United States)

    Soeta, Yoshiharu; Shimokura, Ryota; Kim, Yong Hee; Ohsawa, Tomohiro; Ito, Ken

    2013-05-01

    Although temples are important buildings in the Buddhist community, the acoustic quality has not been examined in detail. Buddhist monks change the location and direction according to the ceremony, and associated acoustical changes have not yet been examined scientifically. To discuss the desired acoustics of temples, it is necessary to know the acoustic characteristics appropriate for each phase of a ceremony. In this study, acoustic measurements were taken at various source locations and directions in Japanese temples. A directional loudspeaker was used as the source to provide vocal acoustic fields, and impulse responses were measured and analyzed. The speech transmission index was higher and the interaural cross-correlation coefficient was lower for the sound source directed toward the side wall than that directed toward the altar. This suggests that the change in direction improves speech intelligibility, and the asymmetric property of direct sound and complex reflections from the altar and side wall increases the apparent source width. The large and coupled-like structure of the altar of a Buddhist temple may have reinforced the reverberation components and the table in the altar, which is called the "syumidan," may have decreased binaural coherence.

  17. Residual stress measurement with focused acoustic waves and direct comparison with X-ray diffraction stress measurements

    International Nuclear Information System (INIS)

    Sathish, Shamachary; Moran, Thomas J.; Martin, Richard W.; Reibel, Richard

    2005-01-01

    The technique of measuring small changes in acoustic wave velocity due to external or internal stress has been used for quantitative determination of residual stress in materials during the last decade. Application of similar methodology with focused acoustic waves leads to residual stress measurement with spatial resolution of a few millimeters to a few microns. The high spatial resolution residual stress measurement required development of new methodologies in both the design of acoustic lenses and the instrumentation for acoustic wave velocity determination. This paper presents two new methodologies developed for the measurement of residual stress with spatial resolution of a few millimeters. The design of new type of acoustic lens for achieving higher spatial resolution in residual stress measurement is introduced. Development of instrumentation for high precision local surface wave velocity measurement will be presented. Residual stresses measured around a crack tip in a sample of Ti-6A1-4V using a focused beam will be compared with X-ray diffraction measurements performed on the same region of the sample. Results of residual stress measurements along a direction perpendicular to the electron beam weld in a sample of Ti-6A1-4V, determined using focused acoustic waves and X-ray diffraction technique, are also presented. The spatial resolution and penetration depth of X-rays and focused acoustic beams with reference to residual stress measurements are discussed

  18. Photopolarimetric properties of leaf and vegetation covers over a wide range of measurement directions

    Science.gov (United States)

    Sun, Zhongqiu; Peng, Zhiyan; Wu, Di; Lv, Yunfeng

    2018-02-01

    The optical scattering property of the target is the essential signal for passive remote sensing applications. To deepen our understanding of the light reflected from vegetation, we present results of photopolarimetric laboratory measurements from single leaf and two vegetation covers (planophile and erectophile) over a wide range of viewing directions. The bidirectional polarized reflectance factor (BPRF) was used to characterize the polarization property of our samples. We observed positive and negative polarization (-BPRFQ) of all samples in the forward scattering and backward scattering directions, respectively. Based on the comparison of the BPRF among single leaf, planophile vegetation and erectophile vegetation, our measurements demonstrate that the orientation of the leaf is a key factor in describing the amount of polarization in the forward scattering direction. Our measurements also validated certain model results stating that (1) specular reflection generates a portion of polarization in the forward scattering direction and diffuses scattering of polarized light in all hemisphere directions, (2) BPRFU is anti-symmetric in the principal plane from a recent study in which the authors simulated the polarized reflectance of vegetation cover using the vector radiative transfer theory. These photopolarimetric measurement results, which can be completely explained by the theoretical results, are useful in remote sensing applications to vegetation.

  19. Direct LSC method for determination of bio-origin by C-14 measurement

    International Nuclear Information System (INIS)

    Kristof, Romana; Kozar Logar, Jasmina

    2017-01-01

    The aim of the research was to test the generalized direct liquid scintillation spectrometry (LSC) method for bio-origin determination by measurement of C-14. Examples of diversified items with known and unknown bio-origin were measured by liquid scintillation counting and analyzed by procedures, developed for fuel samples. Bio-origin of fuels, lubricants and monomer resins were successfully determined via direct LSC method after simple sample preparation with acceptable accuracy and trueness despite their diversity in color, viscosity, density or chemical composition. (author)

  20. Direct Heat-Flux Measurement System (MDF) for Solar central Receiver Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ballestrin, J.

    2001-07-01

    A direct flux measurement system, MDF, has been designed, constructed and mounted on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA) in addition to an indirect flux measurement system based on a CCD camera. It's one of the main future objectives to compare systematically both measurements of the concentrated solar power, increasing in this way the confidence in the estimate of this quantity. Today everything is prepared to perform the direct flux measurement on the aperture of solar receivers: calorimeter array, data acquisition system and software. the geometry of the receiver determines the operation and analysis procedures to obtain the indecent power onto the defined area. The study of previous experiences with direct flux measurement systems ha been useful to define a new simpler and more accurate system. A description of each component of the MDF system is included, focusing on the heat-flux sensors or calorimeters, which enables these measurements to be done in a few seconds without water-cooling. The incident solar power and the spatial flux distribution on the aperture of the volumetric receiver Hitrec II are supplied by the above-mentioned MDF system. The first results obtained during the evaluation of this solar receiver are presented including a sunrise-sunset test. All these measurements have been concentrated in one coefficient that describes the global behavior of the Solar Power Plant. (Author) 18 refs.

  1. Dimension reduction of frequency-based direct Granger causality measures on short time series.

    Science.gov (United States)

    Siggiridou, Elsa; Kimiskidis, Vasilios K; Kugiumtzis, Dimitris

    2017-09-01

    The mainstream in the estimation of effective brain connectivity relies on Granger causality measures in the frequency domain. If the measure is meant to capture direct causal effects accounting for the presence of other observed variables, as in multi-channel electroencephalograms (EEG), typically the fit of a vector autoregressive (VAR) model on the multivariate time series is required. For short time series of many variables, the estimation of VAR may not be stable requiring dimension reduction resulting in restricted or sparse VAR models. The restricted VAR obtained by the modified backward-in-time selection method (mBTS) is adapted to the generalized partial directed coherence (GPDC), termed restricted GPDC (RGPDC). Dimension reduction on other frequency based measures, such the direct directed transfer function (dDTF), is straightforward. First, a simulation study using linear stochastic multivariate systems is conducted and RGPDC is favorably compared to GPDC on short time series in terms of sensitivity and specificity. Then the two measures are tested for their ability to detect changes in brain connectivity during an epileptiform discharge (ED) from multi-channel scalp EEG. It is shown that RGPDC identifies better than GPDC the connectivity structure of the simulated systems, as well as changes in the brain connectivity, and is less dependent on the free parameter of VAR order. The proposed dimension reduction in frequency measures based on VAR constitutes an appropriate strategy to estimate reliably brain networks within short-time windows. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. New strain measurement method at axial tensile test of thin films through direct imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jong-Eun [Department of Automotive Engineering, Seoul National Uinversity of Technolgy, 172 Gongneung-2 Dong, Nowon-Gu, Seoul (Korea, Republic of); Park, Jun-Hyub [Department of Mechatronics Engineering, College of Engineering, Tongmyong University, 535, Yongdang-Dong, Nam-Gu, Busan 608-711 (Korea, Republic of); Kang, Dong-Joong [School of Mechanical Eng., Pusan National University, Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea, Republic of)], E-mail: jhyubpark@korea.com

    2008-09-07

    This paper proposes a new method for measuring strain during a tensile test of the specimen with micrometre size through direct imaging. A specimen was newly designed for adoption of direct imaging which was the main contribution of the proposed system. The structure of the specimen has eight indicators that make it possible to adopt direct imaging and it is fabricated using the same process of microelectromechanical system (MEMS) devices to guarantee the feasibility of the tensile test. We implemented a system for non-contact in situ measurement of strain with the specimen, the image-based displacement measurement system. Extension of the gauge length in the specimen could be found robustly by computing the positions of the eight rectangular-shape indicators on the image. Also, for an easy setup procedure, the region of interest was found automatically through the analysis of the edge projection profile along the horizontal direction. To gain confidence in the reliability of the system, the tensile test for the Al-3%Ti thin film was performed, which is widely used as a material in MEMS devices. Tensile tests were performed and displacements were measured using the proposed method and also the capacitance type displacement sensor for comparison. It is demonstrated that the new strain measurement system can be effectively used in the tensile test of the specimen at microscale with easy setup and better accuracy.

  3. Measuring spatially- and directionally-varying light scattering from biological material.

    Science.gov (United States)

    Harvey, Todd Alan; Bostwick, Kimberly S; Marschner, Steve

    2013-05-20

    Light interacts with an organism's integument on a variety of spatial scales. For example in an iridescent bird: nano-scale structures produce color; the milli-scale structure of barbs and barbules largely determines the directional pattern of reflected light; and through the macro-scale spatial structure of overlapping, curved feathers, these directional effects create the visual texture. Milli-scale and macro-scale effects determine where on the organism's body, and from what viewpoints and under what illumination, the iridescent colors are seen. Thus, the highly directional flash of brilliant color from the iridescent throat of a hummingbird is inadequately explained by its nano-scale structure alone and questions remain. From a given observation point, which milli-scale elements of the feather are oriented to reflect strongly? Do some species produce broader "windows" for observation of iridescence than others? These and similar questions may be asked about any organisms that have evolved a particular surface appearance for signaling, camouflage, or other reasons. In order to study the directional patterns of light scattering from feathers, and their relationship to the bird's milli-scale morphology, we developed a protocol for measuring light scattered from biological materials using many high-resolution photographs taken with varying illumination and viewing directions. Since we measure scattered light as a function of direction, we can observe the characteristic features in the directional distribution of light scattered from that particular feather, and because barbs and barbules are resolved in our images, we can clearly attribute the directional features to these different milli-scale structures. Keeping the specimen intact preserves the gross-scale scattering behavior seen in nature. The method described here presents a generalized protocol for analyzing spatially- and directionally-varying light scattering from complex biological materials at multiple

  4. Direct Measurement of the 7Be Solar Neutrino Flux with 192 Days of Borexino Data

    International Nuclear Information System (INIS)

    Arpesella, C.; Di Pietro, G.; Monzani, M. E.; Back, H. O.; Hardy, S.; Joyce, M.; Manecki, S.; Raghavan, R. S.; Rountree, D.; Vogelaar, R. B.; Balata, M.; Di Credico, A.; Gazzana, S.; Korga, G.; Laubenstein, M.; Orsini, M.; Papp, L.; Razeto, A.; Tartaglia, R.; Bellini, G.

    2008-01-01

    We report the direct measurement of the 7 Be solar neutrino signal rate performed with the Borexino detector at the Laboratori Nazionali del Gran Sasso. The interaction rate of the 0.862 MeV 7 Be neutrinos is 49±3 stat ±4 syst counts/(day·100 ton). The hypothesis of no oscillation for 7 Be solar neutrinos is inconsistent with our measurement at the 4σ C.L. Our result is the first direct measurement of the survival probability for solar ν e in the transition region between matter-enhanced and vacuum-driven oscillations. The measurement improves the experimental determination of the flux of 7 Be, pp, and CNO solar ν e , and the limit on the effective neutrino magnetic moment using solar neutrinos

  5. Measurement of the sea surface wind speed and direction by an airborne microwave radar altimeter

    Energy Technology Data Exchange (ETDEWEB)

    Nekrassov, A. [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. fuer Hydrophysik

    2001-07-01

    A pilot needs operational information about wind over sea as well as wave height to provide safety of a hydroplane landing on water. Near-surface wind speed and direction can be obtained with an airborne microwave scatterometer, radar designed for measuring the scatter characteristics of a surface. Mostly narrow-beam antennas are applied for such wind measurement. Unfortunately, a microwave narrow-beam antenna has considerable size that hampers its placing on flying apparatus. In this connection, a possibility to apply a conventional airborne radar altimeter as a scatterometer with a nadir-looking wide-beam antenna in conjunction with Doppler filtering for recovering the wind vector over sea is discussed, and measuring algorithms of sea surface wind speed and direction are proposed. The obtained results can be used for creation of an airborne radar system for operational measurement of the sea roughness characteristics and for safe landing of a hydroplane on water. (orig.)

  6. Barkhausen noise measurements give direct observation of magnetocrystalline anisotropy energy in ferromagnetic polycrystals

    International Nuclear Information System (INIS)

    Espina-Hernández, J H; Pérez-Benítez, J A; Caleyo, F; Hallen, J M; Baudin, T; Helbert, A L

    2013-01-01

    This paper presents experimental evidence of the capability of Barkhausen noise measurements to estimate the angular dependence of the average magnetocrystalline energy in soft magnetic polycrystalline materials. Three different API 5L steel samples, all obtained from out-of-service pipelines, were investigated using crystallographic texture and Barkhausen noise measurements. The angular dependence of the rms voltage of the Barkhausen signal was determined in each sample for the time band corresponding to the saturation-to-remanence part of the hysteresis loop where irreversible domain rotation occurs. For each angular position, the rms voltage of the Barkhausen noise signal in this time band was interpreted as a direct measure of the magnetocrystalline anisotropy energy of the polycrystal in the corresponding direction. A strong correlation between the angular dependence of both the rms voltage of the Barkhausen signal in the time band of interest and the average magnetocrystalline energy obtained from crystallographic texture measurements was found experimentally. (fast track communication)

  7. Using Measured Plane-of-Array Data Directly in Photovoltaic Modeling: Methodology and Validation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Janine; Freestate, David; Riley, Cameron; Hobbs, William

    2016-11-01

    Measured plane-of-array (POA) irradiance may provide a lower-cost alternative to standard irradiance component data for photovoltaic (PV) system performance modeling without loss of accuracy. Previous work has shown that transposition models typically used by PV models to calculate POA irradiance from horizontal data introduce error into the POA irradiance estimates, and that measured POA data can correlate better to measured performance data. However, popular PV modeling tools historically have not directly used input POA data. This paper introduces a new capability in NREL's System Advisor Model (SAM) to directly use POA data in PV modeling, and compares SAM results from both POA irradiance and irradiance components inputs against measured performance data for eight operating PV systems.

  8. Direct measurements of the Gibbs free energy of OH using a CW tunable laser

    Science.gov (United States)

    Killinger, D. K.; Wang, C. C.

    1979-01-01

    The paper describes an absorption measurement for determining the Gibbs free energy of OH generated in a mixture of water and oxygen vapor. These measurements afford a direct verification of the accuracy of thermochemical data of H2O at high temperatures and pressures. The results indicate that values for the heat capacity of H2O obtained through numerical computations are correct within an experimental uncertainty of 0.15 cal/mole K.

  9. The Promotion of Foreign Direct Investment into Japan - The Measures' Impact on FDI Series

    OpenAIRE

    Maiko Wada

    2005-01-01

    At the occasion of delivering the fiscal year 2003 policy speech, Prime Minister Junichiro Koizumi proposed to double foreign direct investment (hereafter, FDI) stock into Japan within five years to revitalize the Japanese economy. Against this background, various measures aimed at promoting FDI into Japan have been investigated and implemented by the government and concerned ministries. A number of significant measures implemented in the most recent years to improve the investment environmen...

  10. Direct Measurements of Smartphone Screen-Time: Relationships with Demographics and Sleep

    OpenAIRE

    Christensen, Matthew A.; Bettencourt, Laura; Kaye, Leanne; Moturu, Sai T.; Nguyen, Kaylin T.; Olgin, Jeffrey E.; Pletcher, Mark J.; Marcus, Gregory M.

    2016-01-01

    Background Smartphones are increasingly integrated into everyday life, but frequency of use has not yet been objectively measured and compared to demographics, health information, and in particular, sleep quality. Aims The aim of this study was to characterize smartphone use by measuring screen-time directly, determine factors that are associated with increased screen-time, and to test the hypothesis that increased screen-time is associated with poor sleep. Methods We performed a cross-sectio...

  11. Direct measurement of the Cu oxidation number of cuprate superconductor ceramics

    International Nuclear Information System (INIS)

    Dankhazi, Z.; Szasz, A.; Kojnok, J.; Gal, M.; Torkos, K.; Solymos, K.; Kirchmayr, H.; Mueller, H.; Watson, L.M.

    1991-01-01

    The Cu oxidation number of YBa 2 Cu 3 O 7 was measured directly by soft X-ray fluorescent spectroscopy both at room temperature and at liquid N 2 temperature. The measurements are based on a calibration curve from different Ba-O compounds. The effects of changes in oxidation number above and below the transition temperature and its role in high-T c superconductivity are discussed

  12. Direct measurement of the magnetocaloric effect in Tb5Si2Ge2

    International Nuclear Information System (INIS)

    Tocado, L.; Palacios, E.; Burriel, R.

    2005-01-01

    A method for measuring the adiabatic temperature change ΔT S upon quasi-static application of an external magnetic field H is proposed. ΔT S is directly measured with an accuracy better than 0.01K. Results of experiments on the giant magnetocaloric compound Tb 5 Si 2 Ge 2 are compared with those obtained from magnetization and heat capacity in an applied field

  13. Using a simple apparatus to measure direct and diffuse photosynthetically active radiation at remote locations.

    Directory of Open Access Journals (Sweden)

    Michael J Cruse

    Full Text Available Plant canopy interception of photosynthetically active radiation (PAR drives carbon dioxide (CO2, water and energy cycling in the soil-plant-atmosphere system. Quantifying intercepted PAR requires accurate measurements of total incident PAR above canopies and direct beam and diffuse PAR components. While some regional data sets include these data, e.g. from Atmospheric Radiation Measurement (ARM Program sites, they are not often applicable to local research sites because of the variable nature (spatial and temporal of environmental variables that influence incoming PAR. Currently available instrumentation that measures diffuse and direct beam radiation separately can be cost prohibitive and require frequent adjustments. Alternatively, generalized empirical relationships that relate atmospheric variables and radiation components can be used but require assumptions that increase the potential for error. Our goal here was to construct and test a cheaper, highly portable instrument alternative that could be used at remote field sites to measure total, diffuse and direct beam PAR for extended time periods without supervision. The apparatus tested here uses a fabricated, solar powered rotating shadowband and other commercially available parts to collect continuous hourly PAR data. Measurements of total incident PAR had nearly a one-to-one relationship with total incident radiation measurements taken at the same research site by an unobstructed point quantum sensor. Additionally, measurements of diffuse PAR compared favorably with modeled estimates from previously published data, but displayed significant differences that were attributed to the important influence of rapidly changing local environmental conditions. The cost of the system is about 50% less than comparable commercially available systems that require periodic, but not continual adjustments. Overall, the data produced using this apparatus indicates that this instrumentation has the

  14. Comparative Analysis of Direct and Indirect 131I Measurement Methods from the Stack to Outdoor

    Directory of Open Access Journals (Sweden)

    G. Suhariyono

    2017-11-01

    Full Text Available The radioisotope production facility at PUSPIPTEK Serpong produces and processes 131I that can disperse to the settlements (community and the environment around the Serpong Nuclear Area (SNA. 131I is produced routinely for medical uses in hospitals and pharmacies, for both domestic uses and export. 131I is a beta and gamma emitting radioactive material and can cause thyroid cancer. The problem was that there was so far no research and in-depth assessment of the aerial dispersion of 131I radioactivity emitted from the radioisotope production stack to the environment at actual conditions. The research was conducted through simultaneous measurement of 131I radioactivity in the stack of the 131I radioisotope production facility, Serpong, and outdoor in house courtyards around SNA in normal condition (no accident based on the variations of the distance and wind direction. Direct measurements were carried out with a portable in-situ NaI(Tl detector at outdoor, and with a LaBr3 detector in the stack. Indirect measurements were carried out by using charcoal filter and vacuum pump in the stack and outdoor. The direct measurement method has many advantages over the indirect measurement. The direct measurement method was found to be more accurate, less expensive, easier to operate, needing just one operator in its implementation, portable, and can be operated continuously and for long durations. The overall activity concentrations of 131I on average obtained by either direct or indirect method were still below the upper limit of 131I activity concentration in the air (530 Bq/m3 stipulated by the Regulation of the Chairman of BAPETEN (Perka BAPETEN No. 7/2013. 

  15. Calculating meal glycemic index by using measured and published food values compared with directly measured meal glycemic index.

    Science.gov (United States)

    Dodd, Hayley; Williams, Sheila; Brown, Rachel; Venn, Bernard

    2011-10-01

    Glycemic index (GI) testing is normally based on individual foods, whereas GIs for meals or diets are based on a formula using a weighted sum of the constituents. The accuracy with which the formula can predict a meal or diet GI is questionable. Our objective was to compare the GI of meals, obtained by using the formula and by using both measured food GI and published values, with directly measured meal GIs. The GIs of 7 foods were tested in 30 healthy people. The foods were combined into 3 meals, each of which provided 50 g available carbohydrate, including a staple (potato, rice, or spaghetti), vegetables, sauce, and pan-fried chicken. The mean (95% CI) meal GIs determined from individual food GI values and by direct measurement were as follows: potato meal [predicted, 63 (56, 70); measured, 53 (46, 62)], rice meal [predicted, 51 (45, 56); measured, 38 (33, 45)], and spaghetti meal [predicted, 54 (49, 60); measured, 38 (33, 44)]. The predicted meal GIs were all higher than the measured GIs (P < 0.001). The extent of the overestimation depended on the particular food, ie, 12, 15, and 19 GI units (or 22%, 40%, and 50%) for the potato, rice, and spaghetti meals, respectively. The formula overestimated the GI of the meals by between 22% and 50%. The use of published food values also overestimated the measured meal GIs. Investigators using the formula to calculate a meal or diet GI should be aware of limitations in the method. This trial is registered with the Australian and New Zealand Clinical Trials Registry as ACTRN12611000210976.

  16. An accuracy measurement method for star trackers based on direct astronomic observation.

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-03-07

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.

  17. Optical-feedback semiconductor laser Michelson interferometer for displacement measurements with directional discrimination

    International Nuclear Information System (INIS)

    Rodrigo, Peter John; Lim, May; Saloma, Caesar

    2001-01-01

    An optical-feedback semiconductor laser Michelson interferometer (OSMI) is presented for measuring microscopic linear displacements without ambiguity in the direction of motion. The two waves from the interferometer arms, one from the reference mirror and the other from the reflecting moving target, are fed back into the lasing medium (λ=830 nm), causing variations in the laser output power. We model the OSMI into an equivalent Fabry-Perot resonator and derive the dependence of the output power (and the junction voltage) on the path difference between the two interferometer arms. Numerical and experimental results consistently show that the laser output power varies periodically (period, λ/2) with path difference. The output power variation exhibits an asymmetric behavior with the direction of motion, which is used to measure, at subwavelength resolution, the displacement vector (both amplitude and direction) of the moving sample. Two samples are considered in the experiments: (i) a piezoelectric transducer and (ii) an audio speaker

  18. A new measurement of direct CP violation in two pion decays of the neutral kaon

    CERN Document Server

    Fanti, V.; Marras, D.; Musa, L.; Bevan, A.J.; Gershon, T.J.; Hay, B.; Moore, R.W.; Moore, K.N.; Munday, D.J.; Needham, M.D.; Parker, Michael Andrew; Takach, S.F.; White, T.O.; Wotton, S.A.; Barr, G.; Blumer, H.; Bocquet, G.; Bremer, J.; Ceccucci, A.; Cogan, J.; Cundy, D.; Doble, N.; Funk, W.; Gatignon, L.; Gianoli, A.; Gonidec, A.; Govi, G.; Grafstrom, P.; Kesseler, G.; Kubischta, W.; Lacourt, A.; Luitz, S.; Matheys, J.P.; Norton, A.; Palestini, S.; Panzer-Steindel, B.; Peyaud, B.; Schinzel, D.; Taureg, H.; Velasco, M.; Vossnack, O.; Wahl, Heinrich; Wirrer, G.; Gaponenko, A.; Kekelidze, V.; Madigozhin, D.; Mestvirishvili, A.; Potrebenikov, Yu.; Tatishvili, G.; Tkatchev, A.; Zinchenko, A.; Bertolotto, L.; Boyle, O.; Knowles, I.G.; Martin, V.J.; Parsons, H.L.C.; Peach, K.J.; Talamonti, C.; Contalbrigo, M.; Dalpiaz, P.; Duclos, J.; Formica, A.; Frabetti, P.L.; Martini, M.; Petrucci, F.; Savrie, M.; Bizzeti, A.; Calvetti, M.; Collazuol, G.; Graziani, G.; Iacopini, E.; Lenti, M.; Michetti, A.; Becker, H.G.; Buchholz, P.; Coward, D.H.; Ebersberger, C.; Fox, H.; Kalter, A.; Kleinknecht, K.; Koch, U.; Kopke, L.; Renk, B.; Scheidt, J.; Schmidt, J.; Schonharting, V.; Schue, Y.; Wilhelm, R.; Wittgen, M.; Chollet, J.C.; Crepe-Renaudin, Sabine; Fayard, L.; Iconomidou-Fayard, L.; Ocariz, J.; Unal, G.; Vattolo, D.; Wingerter-Seez, I.; Anzivino, G.; Bordacchini, F.; Cenci, P.; Lubrano, P.; Nappi, A.; Pepe, M.; Punturo, M.; Bertanza, L.; Bigi, A.; Calafiura, P.; Carosi, R.; Casali, R.; Cerri, C.; Cirilli, M.; Costantini, F.; Fantechi, R.; Giudici, S.; Gorini, B.; Mannelli, I.; Marzulli, V.; Pierazzini, G.; Raffaelli, F.; Sozzi, M.; Cheze, J.B.; De Beer, M.; Debu, P.; Granier de Cassagnac, R.; Hristov, P.; Mazzucato, E.; Schanne, S.; Turlay, R.; Vallage, B.; Augustin, I.; Bender, M.; Holder, M.; Ziolkowski, M.; Arcidiacono, R.; Biino, C.; Cester, R.; Marchetto, F.; Menichetti, Ezio A.; Pastrone, N.; Nassalski, J.; Rondio, E.; Szleper, M.; Wislicki, W.; Wronka, S.; Dibon, H.; Fischer, G.; Jeitler, M.; Markytan, M.; Mikulec, I.; Neuhofer, G.; Pernicka, M.; Taurok, A.

    1999-01-01

    The NA48 experiment at CERN has performed a new measurement of direct CP violation, based on data taken in 1997 by simultaneously collecting $kl$ and $ks$ decays into $pipin$ and $pipic$. The result for the CP violating parameter $ epr$ is $(18.5 pm 4.5 mathrm{(stat)} pm 5.8 mathrm{(syst)}) imes10^{-4}$.

  19. Direct measurements of air layer profiles under impacting droplets using high-speed color interferometry

    NARCIS (Netherlands)

    van der Veen, Roeland; Tran, Tuan; Lohse, Detlef; Sun, Chao

    2012-01-01

    A drop impacting on a solid surface deforms before the liquid makes contact with the surface. We directly measure the time evolution of the air layer profile under the droplet using high-speed color interferometry, obtaining the air layer thickness before and during the wetting process. Based on the

  20. A Direct inverse model to determine permeability fields from pressure and flow rate measurements

    NARCIS (Netherlands)

    Brouwer, G.K.; Fokker, P.A.; Wilschut, F.; Zijl, W.

    2008-01-01

    The determination of the permeability field from pressure and flow rate measurements in wells is a key problem in reservoir engineering. This paper presents a Double Constraint method for inverse modeling that is an example of direct inverse modeling. The method is used with a standard

  1. A direct measurement of the baryonic mass function of galaxies & implications for the galactic baryon fraction

    NARCIS (Netherlands)

    Papastergis, Emmanouil; Cattaneo, Andrea; Huang, Shan; Giovanelli, Riccardo; Haynes, Martha P.

    2012-01-01

    We use both an HI-selected and an optically-selected galaxy sample to directly measure the abundance of galaxies as a function of their "baryonic" mass (stars + atomic gas). Stellar masses are calculated based on optical data from the Sloan Digital Sky Survey (SDSS) and atomic gas masses are

  2. Direct measurement of the inelastic neutron acceleration by 177mLu

    Directory of Open Access Journals (Sweden)

    Menelle A.

    2010-03-01

    Full Text Available The inelastic neutron acceleration (INNA cross section on the long-lived isomer state of 177mLu has been measured from a new isomeric target using a direct method. The detection of high energy neutrons has been performed using a specially designed setup and a cold neutron beam at the ORPHEE reactor facility in Saclay.

  3. Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; van den Berg, Albert

    2004-01-01

    The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with

  4. Overtones of isoscalar giant resonances studied in direct particle decay measurements

    NARCIS (Netherlands)

    Hunyadi, M; van den Berg, AM; Csatlos, M; Csige, L; Davids, B; Garg, U; Gulyas, J; Harakeh, MN; de Huu, MA; Krasznahorkay, A; Sohler, D; Wortche, HJ

    The isoscalar giant dipole resonance (ISGDR), which is the lowest-energy overtone mode of the isoscalar giant resonances, has been studied in some medium-heavy and heavy nuclei in coincidence measurements. The observation of the direct nucleon decay channels significantly helped to enhance giant

  5. Direct Measurement of the Band Structure of a Buried Two-Dimensional Electron Gas

    DEFF Research Database (Denmark)

    Miwa, Jill; Hofmann, Philip; Simmons, Michelle Y.

    2013-01-01

    We directly measure the band structure of a buried two dimensional electron gas (2DEG) using angle resolved photoemission spectroscopy. The buried 2DEG forms 2 nm beneath the surface of p-type silicon, because of a dense delta-type layer of phosphorus n-type dopants which have been placed there...

  6. FoCal – A high granularity electromagnetic calorimeter for forward direct photon measurements

    NARCIS (Netherlands)

    Zhang, C.

    2017-01-01

    The measurement of direct photon production at forward rapidity (y∼3−5) at the LHC provides access to the structure of protons and nuclei at very small values of fractional momentum (x∼10−5). FoCal, an extremely-high-granularity Forward Calorimeter covering 3.3<η<5.3 is proposed as a detector

  7. Direct measurement of the charge distribution along a biased carbon nanotube bundle using electron holography

    DEFF Research Database (Denmark)

    Beleggia, Marco; Kasama, Takeshi; Dunin-Borkowski, Rafal E.

    2011-01-01

    Nanowires and nanotubes can be examined in the transmission electron microscope under an applied bias. Here we introduce a model-independent method, which allows the charge distribution along a nanowire or nanotube to be measured directly from the Laplacian of an electron holographic phase image....

  8. Direct and indirect measures of speech articulator motions using low power EM sensors

    International Nuclear Information System (INIS)

    Barnes, T; Burnett, G; Gable, T; Holzrichter, J F; Ng, L

    1999-01-01

    Low power Electromagnetic (EM) Wave sensors can measure general properties of human speech articulator motions, as speech is produced. See Holzrichter, Burnett, Ng, and Lea, J.Acoust.Soc.Am. 103 (1) 622 (1998). Experiments have demonstrated extremely accurate pitch measurements ( and lt; 1 Hz per pitch cycle) and accurate onset of voiced speech. Recent measurements of pressure-induced tracheal motions enable very good spectra and amplitude estimates of a voiced excitation function. The use of the measured excitation functions and pitch synchronous processing enable the determination of each pitch cycle of an accurate transfer function and, indirectly, of the corresponding articulator motions. In addition, direct measurements have been made of EM wave reflections from articulator interfaces, including jaw, tongue, and palate, simultaneously with acoustic and glottal open/close signals. While several types of EM sensors are suitable for speech articulator measurements, the homodyne sensor has been found to provide good spatial and temporal resolution for several applications

  9. Experience with novel technologies for direct measurement of atmospheric NO2

    Science.gov (United States)

    Hueglin, Christoph; Hundt, Morten; Mueller, Michael; Schwarzenbach, Beat; Tuzson, Bela; Emmenegger, Lukas

    2017-04-01

    Nitrogen dioxide (NO2) is an air pollutant that has a large impact on human health and ecosystems, and it plays a key role in the formation of ozone and secondary particulate matter. Consequently, legal limit values for NO2 are set in the EU and elsewhere, and atmospheric observation networks typically include NO2 in their measurement programmes. Atmospheric NO2 is principally measured by chemiluminescence detection, an indirect measurement technique that requires conversion of NO2 into nitrogen monoxide (NO) and finally calculation of NO2 from the difference between total nitrogen oxides (NOx) and NO. Consequently, NO2 measurements with the chemiluminescence method have a relatively high measurement uncertainty and can be biased depending on the selectivity of the applied NO2 conversion method. In the past years, technologies for direct and selective measurement of NO2 have become available, e.g. cavity attenuated phase shift spectroscopy (CAPS), cavity enhanced laser absorption spectroscopy and quantum cascade laser absorption spectrometry (QCLAS). These technologies offer clear advantages over the indirect chemiluminescence method. We tested the above mentioned direct measurement techniques for NO2 over extended time periods at atmospheric measurement stations and report on our experience including comparisons with co-located chemiluminescence instruments equipped with molybdenum as well as photolytic NO2 converters. A still open issue related to the direct measurement of NO2 is instrument calibration. Accurate and traceable reference standards and NO2 calibration gases are needed. We present results from the application of different calibration strategies based on the use of static NO2 calibration gases as well as dynamic NO2 calibration gases produced by permeation and by gas-phase titration (GPT).

  10. Direct measurements of neutral density depletion by two-photon absorption laser-induced fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Aanesland, A.; Liard, L.; Leray, G.; Jolly, J.; Chabert, P.

    2007-01-01

    The ground state density of xenon atoms has been measured by spatially resolved laser-induced fluorescence spectroscopy with two-photon excitation in the diffusion chamber of a magnetized Helicon plasma. This technique allows the authors to directly measure the relative variations of the xenon atom density without any assumptions. A significant neutral gas density depletion was measured in the core of the magnetized plasma, in agreement with previous theoretical and experimental works. It was also found that the neutral gas density was depleted near the radial walls

  11. Direct measurement of the top quark mass in $p\\bar p$ collisions at D0

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, Oleg [Kirchhoff Inst. Phys.

    2017-10-11

    The mass of the top quark is a fundamental parameter of the Standard Model and has to be determined experimentally. In these proceedings, I review recent direct measurements of the top quark mass in $p\\bar p$ collisions at $\\sqrt s=1.96$ TeV recorded by the D0 experiment at the Tevatron. The measurements are performed in final states containing one and two charged leptons. I will present the legacy combination of all top quark mass measurements from the D0 experiment and their combination with results from the CDF experiment. A relative precision of down to 0.3\\% is attained.

  12. Measurement of Rank and Other Properties of Direct and Scattered Signals

    Directory of Open Access Journals (Sweden)

    Svante Björklund

    2016-01-01

    Full Text Available We have designed an experiment for low-cost indoor measurements of rank and other properties of direct and scattered signals with radar interference suppression in mind. The signal rank is important also in many other applications, for example, DOA (Direction of Arrival estimation, estimation of the number of and location of transmitters in electronic warfare, and increasing the capacity in wireless communications. In real radar applications, such measurements can be very expensive, for example, involving airborne radars with array antennas. We have performed the measurements in an anechoic chamber with several transmitters, a receiving array antenna, and a moving reflector. Our experiment takes several aspects into account: transmitted signals with different correlation, decorrelation of the signals during the acquisition interval, covariance matrix estimation, noise eigenvalue spread, calibration, near-field compensation, scattering in a rough surface, and good control of the influencing factors. With our measurements we have observed rank, DOA spectrum, and eigenpatterns of direct and scattered signals. The agreement of our measured properties with theoretic and simulated results in the literature shows that our experiment is realistic and sound. The detailed description of our experiment could serve as help for conducting other well-controlled experiments.

  13. A direct-measurement technique for estimating discharge-chamber lifetime. [for ion thrusters

    Science.gov (United States)

    Beattie, J. R.; Garvin, H. L.

    1982-01-01

    The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

  14. Mathematical modeling for corrosion environment estimation based on concrete resistivity measurement directly above reinforcement

    International Nuclear Information System (INIS)

    Lim, Young-Chul; Lee, Han-Seung; Noguchi, Takafumi

    2009-01-01

    This study aims to formulate a resistivity model whereby the concrete resistivity expressing the environment of steel reinforcement can be directly estimated and evaluated based on measurement immediately above reinforcement as a method of evaluating corrosion deterioration in reinforced concrete structures. It also aims to provide a theoretical ground for the feasibility of durability evaluation by electric non-destructive techniques with no need for chipping of cover concrete. This Resistivity Estimation Model (REM), which is a mathematical model using the mirror method, combines conventional four-electrode measurement of resistivity with geometric parameters including cover depth, bar diameter, and electrode intervals. This model was verified by estimation using this model at areas directly above reinforcement and resistivity measurement at areas unaffected by reinforcement in regard to the assessment of the concrete resistivity. Both results strongly correlated, proving the validity of this model. It is expected to be applicable to laboratory study and field diagnosis regarding reinforcement corrosion. (author)

  15. Measurement of spin motions in a storage ring outside the stable polarization direction

    International Nuclear Information System (INIS)

    Akchurin, N.; McPherson, J.; Olchowski, F.; Onel, Y.; Badano, L.; Conte, M.; Bravar, A.; Penzo, A.; Hall, J.; Kreiser, H.

    1993-01-01

    Polarized, stored beams are becoming a more and more important tool in nuclear and high energy physics. In order to measure the beam polarization in a storage ring the polarization vector of the stored beam has to aim, revolution for revolution, over a period of seconds to minutes, into the same, so-called open-quote stableclose quotes, direction. In this paper measurements at the Indiana University Cooler Ring (IUCF) are described in which for the first time in a storage ring oscillations of the polarization vector around this stable direction have been measured. The existence and the dynamics of such oscillations are, for instance, important for a new proposed technique for polarizing stored hadron beams

  16. Measuring Air Temperature in Glazed Ventilated Facades in the Presence of Direct Solar Radiation

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Zanghirella, Fabio; Heiselberg, Per

    2007-01-01

    A distinctive element of buildings with a double glazed façade is naturally or mechanically driven flow in a ventilated cavity. Accurate air temperature measurements in the cavity are crucial to evaluate the dynamic performance of the façade, to predict and control its behavior as a significant...... part of the complete ventilation system. Assessment of necessary cooling/heating loads and of the whole building energy performance will then depend on the accuracy of measured air temperature. The presence of direct solar radiation is an essential element for the façade operation, but it can heavily...... affect measurements of air temperature and may lead to errors of high magnitude using bare thermocouples and even adopting shielding devices. Two different research groups, from Aalborg University and Politecnico di Torino, tested separately various techniques to shield thermocouples from direct...

  17. Underground localization using dual magnetic field sequence measurement and pose graph SLAM for directional drilling

    International Nuclear Information System (INIS)

    Park, Byeolteo; Myung, Hyun

    2014-01-01

    With the development of unconventional gas, the technology of directional drilling has become more advanced. Underground localization is the key technique of directional drilling for real-time path following and system control. However, there are problems such as vibration, disconnection with external infrastructure, and magnetic field distortion. Conventional methods cannot solve these problems in real time or in various environments. In this paper, a novel underground localization algorithm using a re-measurement of the sequence of the magnetic field and pose graph SLAM (simultaneous localization and mapping) is introduced. The proposed algorithm exploits the property of the drilling system that the body passes through the previous pass. By comparing the recorded measurement from one magnetic sensor and the current re-measurement from another magnetic sensor, the proposed algorithm predicts the pose of the drilling system. The performance of the algorithm is validated through simulations and experiments. (paper)

  18. Underground localization using dual magnetic field sequence measurement and pose graph SLAM for directional drilling

    Science.gov (United States)

    Park, Byeolteo; Myung, Hyun

    2014-12-01

    With the development of unconventional gas, the technology of directional drilling has become more advanced. Underground localization is the key technique of directional drilling for real-time path following and system control. However, there are problems such as vibration, disconnection with external infrastructure, and magnetic field distortion. Conventional methods cannot solve these problems in real time or in various environments. In this paper, a novel underground localization algorithm using a re-measurement of the sequence of the magnetic field and pose graph SLAM (simultaneous localization and mapping) is introduced. The proposed algorithm exploits the property of the drilling system that the body passes through the previous pass. By comparing the recorded measurement from one magnetic sensor and the current re-measurement from another magnetic sensor, the proposed algorithm predicts the pose of the drilling system. The performance of the algorithm is validated through simulations and experiments.

  19. Methodological challenges surrounding direct-to-consumer advertising research--the measurement conundrum.

    Science.gov (United States)

    Hansen, Richard A; Droege, Marcus

    2005-06-01

    Numerous studies have focused on the impact of direct-to-consumer (DTC) prescription drug advertising on consumer behavior and health outcomes. These studies have used various approaches to assess exposure to prescription drug advertising and to measure the subsequent effects of such advertisements. The objectives of this article are to (1) discuss measurement challenges involved in DTC advertising research, (2) summarize measurement approaches commonly identified in the literature, and (3) discuss contamination, time to action, and endogeneity as specific problems in measurement design and application. We conducted a review of the professional literature to identify illustrative approaches to advertising measurement. Specifically, our review of the literature focused on measurement of DTC advertising exposure and effect. We used the hierarchy-of-effects model to guide our discussion of processing and communication effects. Other effects were characterized as target audience action, sales, market share, and profit. Overall, existing studies have used a variety of approaches to measure advertising exposure and effect, yet the ability of measures to produce a valid and reliable understanding of the effects of DTC advertising can be improved. Our review provides a framework for conceptualizing DTC measurement, and can be used to identify gaps in the literature not sufficiently addressed by existing measures. Researchers should continue to explore correlations between exposure and effect of DTC advertising, but are obliged to improve and validate measurement in this area.

  20. Use of O2 airglow for calibrating direct atomic oxygen measurements from sounding rockets

    Directory of Open Access Journals (Sweden)

    G. Witt

    2009-12-01

    Full Text Available Accurate knowledge about the distribution of atomic oxygen is crucial for many studies of the mesosphere and lower thermosphere. Direct measurements of atomic oxygen by the resonance fluorescence technique at 130 nm have been made from many sounding rocket payloads in the past. This measurement technique yields atomic oxygen profiles with good sensitivity and altitude resolution. However, accuracy is a problem as calibration and aerodynamics make the quantitative analysis challenging. Most often, accuracies better than a factor 2 are not to be expected from direct atomic oxygen measurements. As an example, we present results from the NLTE (Non Local Thermodynamic Equilibrium sounding rocket campaign at Esrange, Sweden, in 1998, with simultaneous O2 airglow and O resonance fluorescence measurements. O number densities are found to be consistent with the nightglow analysis, but only within the uncertainty limits of the resonance fluorescence technique. Based on these results, we here describe how better atomic oxygen number densities can be obtained by calibrating direct techniques with complementary airglow photometer measurements and detailed aerodynamic analysis. Night-time direct O measurements can be complemented by photometric detection of the O2 (b1∑g+−X3∑g- Atmospheric Band at 762 nm, while during daytime the O2 (a1Δg−X3∑g- Infrared Atmospheric Band at 1.27 μm can be used. The combination of a photometer and a rather simple resonance fluorescence probe can provide atomic oxygen profiles with both good accuracy and good height resolution.

  1. Direct measurement of catalase activity in living cells and tissue biopsies.

    Science.gov (United States)

    Scaglione, Christine N; Xu, Qijin; Ramanujan, V Krishnan

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies - can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Direct measurement of catalase activity in living cells and tissue biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan, E-mail: Ramanujanv@csmc.edu

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  3. Direct measurement of catalase activity in living cells and tissue biopsies

    International Nuclear Information System (INIS)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan

    2016-01-01

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  4. Separation of Rashba and Dresselhaus spin-orbit interactions using crystal direction dependent transport measurements

    International Nuclear Information System (INIS)

    Ho Park, Youn; Kim, Hyung-jun; Chang, Joonyeon; Hee Han, Suk; Eom, Jonghwa; Choi, Heon-Jin; Cheol Koo, Hyun

    2013-01-01

    The Rashba spin-orbit interaction effective field is always in the plane of the two-dimensional electron gas and perpendicular to the carrier wavevector but the direction of the Dresselhaus field depends on the crystal orientation. These two spin-orbit interaction parameters can be determined separately by measuring and analyzing the Shubnikov-de Haas oscillations for various crystal directions. In the InAs quantum well system investigated, the Dresselhaus term is just 5% of the Rashba term. The gate dependence of the oscillation patterns clearly shows that only the Rashba term is modulated by an external electric field

  5. Directed clustering coefficient as a measure of systemic risk in complex banking networks

    Science.gov (United States)

    Tabak, Benjamin M.; Takami, Marcelo; Rocha, Jadson M. C.; Cajueiro, Daniel O.; Souza, Sergio R. S.

    2014-01-01

    Recent literature has focused on the study of systemic risk in complex networks. It is clear now, after the crisis of 2008, that the aggregate behavior of the interaction among agents is not straightforward and it is very difficult to predict. Contributing to this debate, this paper shows that the directed clustering coefficient may be used as a measure of systemic risk in complex networks. Furthermore, using data from the Brazilian interbank network, we show that the directed clustering coefficient is negatively correlated with domestic interest rates.

  6. Precision measurements, dark matter direct detection and LHC Higgs searches in a constrained NMSSM

    International Nuclear Information System (INIS)

    Bélanger, G.; Hugonie, C.; Pukhov, A.

    2009-01-01

    We reexamine the constrained version of the Next-to-Minimal Supersymmetric Standard Model with semi universal parameters at the GUT scale (CNMSSM). We include constraints from collider searches for Higgs and susy particles, upper bound on the relic density of dark matter, measurements of the muon anomalous magnetic moment and of B-physics observables as well as direct searches for dark matter. We then study the prospects for direct detection of dark matter in large scale detectors and comment on the prospects for discovery of heavy Higgs states at the LHC

  7. A review of measurement-based assessments of the aerosol direct radiative effect and forcing

    Directory of Open Access Journals (Sweden)

    H. Yu

    2006-01-01

    Full Text Available Aerosols affect the Earth's energy budget directly by scattering and absorbing radiation and indirectly by acting as cloud condensation nuclei and, thereby, affecting cloud properties. However, large uncertainties exist in current estimates of aerosol forcing because of incomplete knowledge concerning the distribution and the physical and chemical properties of aerosols as well as aerosol-cloud interactions. In recent years, a great deal of effort has gone into improving measurements and datasets. It is thus feasible to shift the estimates of aerosol forcing from largely model-based to increasingly measurement-based. Our goal is to assess current observational capabilities and identify uncertainties in the aerosol direct forcing through comparisons of different methods with independent sources of uncertainties. Here we assess the aerosol optical depth (τ, direct radiative effect (DRE by natural and anthropogenic aerosols, and direct climate forcing (DCF by anthropogenic aerosols, focusing on satellite and ground-based measurements supplemented by global chemical transport model (CTM simulations. The multi-spectral MODIS measures global distributions of aerosol optical depth (τ on a daily scale, with a high accuracy of ±0.03±0.05τ over ocean. The annual average τ is about 0.14 over global ocean, of which about 21%±7% is contributed by human activities, as estimated by MODIS fine-mode fraction. The multi-angle MISR derives an annual average AOD of 0.23 over global land with an uncertainty of ~20% or ±0.05. These high-accuracy aerosol products and broadband flux measurements from CERES make it feasible to obtain observational constraints for the aerosol direct effect, especially over global the ocean. A number of measurement-based approaches estimate the clear-sky DRE (on solar radiation at the top-of-atmosphere (TOA to be about -5.5±0.2 Wm-2 (median ± standard error from various methods over the global ocean. Accounting for thin cirrus

  8. Position measurement of the direct drive motor of Large Aperture Telescope

    Science.gov (United States)

    Li, Ying; Wang, Daxing

    2010-07-01

    Along with the development of space and astronomy science, production of large aperture telescope and super large aperture telescope will definitely become the trend. It's one of methods to solve precise drive of large aperture telescope using direct drive technology unified designed of electricity and magnetism structure. A direct drive precise rotary table with diameter of 2.5 meters researched and produced by us is a typical mechanical & electrical integration design. This paper mainly introduces position measurement control system of direct drive motor. In design of this motor, position measurement control system requires having high resolution, and precisely aligning the position of rotor shaft and making measurement, meanwhile transferring position information to position reversing information corresponding to needed motor pole number. This system has chosen high precision metal band coder and absolute type coder, processing information of coders, and has sent 32-bit RISC CPU making software processing, and gained high resolution composite coder. The paper gives relevant laboratory test results at the end, indicating the position measurement can apply to large aperture telescope control system. This project is subsidized by Chinese National Natural Science Funds (10833004).

  9. Direct localised measurement of electrical resistivity profile in rat and embryonic chick retinas using a microprobe

    Directory of Open Access Journals (Sweden)

    Harald van Lintel

    2010-01-01

    Full Text Available We report an alternative technique to perform a direct and local measurement of electrical resistivities in a layered retinal tissue. Information on resistivity changes along the depth in a retina is important for modelling retinal stimulation by retinal prostheses. Existing techniques for resistivity-depth profiling have the drawbacks of a complicated experimental setup, a less localised resistivity probing and/or lower stability for measurements. We employed a flexible microprobe to measure local resistivity with bipolar impedance spectroscopy at various depths in isolated rat and chick embryo retinas for the first time. Small electrode spacing permitted high resolution measurements and the probe flexibility contributed to stable resistivity profiling. The resistivity was directly calculated based on the resistive part of the impedance measured with the Peak Resistance Frequency (PRF methodology. The resistivity-depth profiles for both rat and chick embryo models are in accordance with previous mammalian and avian studies in literature. We demonstrate that the measured resistivity at each depth has its own PRF signature. Resistivity profiles obtained with our setup provide the basis for the construction of an electric model of the retina. This model can be used to predict variations in parameters related to retinal stimulation and especially in the design and optimisation of efficient retinal implants.

  10. Direct gamma and gamma+jet measurement capability of ATLAS @ LHC Quark Matter 2009 talk

    CERN Document Server

    Baker, MD

    2009-01-01

    Direct photon and photon-jet correlations are ideal tools for tomographic studies of the dense medium created in heavy ion collisions at LHC energies. Due to their weak interactions with the medium, direct photons serve as standard candles for hard-scattering processes, providing a clean calibration of the momentum of the associated jets. The ATLAS detector has excellent capabilities to make these measurements. In particular, the electromagnetic calorimeter, covering the full azimuth for |eta| < 4.9, has longitudinal segmentation and fine transverse segmentation along eta in the range |eta| < 2.4. This combination of fine granularity, longitudinal segmentation and large acceptance is unique among the LHC detectors. We show how this will provide an optimal capability to distinguish direct photon clusters from neutral meson clusters based on their shower profile over a wide acceptance in eta, phi out to 200 GeV in pT . This opens up the possibility for studying various final state photons, includi...

  11. Manufacturing of the ISO 25178-70 material measures with direct laser writing: a feasibility study

    Science.gov (United States)

    Eifler, M.; Hering, J.; von Freymann, G.; Seewig, J.

    2018-06-01

    The standard ISO 25178-70 defines material measures for the calibration of 2D- and 3D-topography measurement devices. Some of the suggested material measures are established within the industrial application for a long time while others have not yet been extensively researched regarding their practical abilities. This paper describes a holistic and systematic investigation of the ISO 25178-70 material measures. The manufacturing of the suggested geometries is executed with two-photon laser lithography, alias direct laser writing (DLW). Since this manufacturing process is not yet frequently used in a material measures context, it is examined regarding its suitability for the fabrication of the ISO 25178-70 material measures. With DLW, it is possible to manufacture multiple material measures on one sample in order to enable a comprehensive calibration of optical topography measurement devices. The manufactured ISO 25178-70 geometries are examined using different 3D-topography measuring devices. In doing so, their abilities regarding the calibration of the devices can be evaluated and the practical feasibility of their industrial application is assessed. For the review of this practical usefulness, varying calibration and evaluation strategies are taken into account.

  12. Comparison of direct measurement methods for headset noise exposure in the workplace

    Directory of Open Access Journals (Sweden)

    Flora G Nassrallah

    2016-01-01

    Full Text Available The measurement of noise exposure from communication headsets poses a methodological challenge. Although several standards describe methods for general noise measurements in occupational settings, these are not directly applicable to noise assessments under communication headsets. For measurements under occluded ears, specialized methods have been specified by the International Standards Organization (ISO 11904 such as the microphone in a real ear and manikin techniques. Simpler methods have also been proposed in some national standards such as the use of general purpose artificial ears and simulators in conjunction with single number corrections to convert measurements to the equivalent diffuse field. However, little is known about the measurement agreement between these various methods and the acoustic manikin technique. Twelve experts positioned circum-aural, supra-aural and insert communication headsets on four different measurement setups (Type 1, Type 2, Type 3.3 artificial ears, and acoustic manikin. Fit-refit measurements of four audio communication signals were taken under quiet laboratory conditions. Data were transformed into equivalent diffuse-field sound levels using third-octave procedures. Results indicate that the Type 1 artificial ear is not suited for the measurement of sound exposure under communication headsets, while Type 2 and Type 3.3 artificial ears are in good agreement with the acoustic manikin technique. Single number corrections were found to introduce a large measurement uncertainty, making the use of the third-octave transformation preferable.

  13. Direct and indirect measurement of somatic cell count as indicator of intramammary infection in dairy goats

    Directory of Open Access Journals (Sweden)

    Olofsson Ida

    2011-03-01

    Full Text Available Abstract Background Mastitis is the most important and costly disease in dairy goat production. Subclinical mastitis is common in goats and is mainly caused by contagious bacteria. Several methods to diagnose subclinical mastitis are available. In this study indirect measurement of somatic cell count (SCC by California Mastitis Test (CMT and direct measurement of SCC using a portable deLaval cell counter (DCC are evaluated. Swedish goat farmers would primarily benefit from diagnostic methods that can be used at the farm. The purpose of the study was to evaluate SCC measured by CMT and DCC as possible markers for intramammary infection (IMI in goats without clinical symptoms of mastitis. Moreover to see how well indirect measurement of SCC (CMT corresponded to direct measurement of SCC (DCC. Method Udder half milk samples were collected once from dairy goats (n = 111, in five different farms in Northern and Central Sweden. Only clinically healthy animals were included in the study. All goats were in mid to late lactation at sampling. Milk samples were analyzed for SCC by CMT and DCC at the farm, and for bacterial growth at the laboratory. Results Intramammary infection, defined as growth of udder pathogens, was found in 39 (18% of the milk samples. No growth was found in 180 (81% samples while 3 (1% samples were contaminated. The most frequently isolated bacterial species was coagulase negative staphylococci (CNS (72% of all isolates, followed by Staphylococcus aureus (23% of all isolates. Somatic cell count measured by DCC was strongly (p = 0.000 associated with bacterial growth. There was also a very strong association between CMT and bacterial growth. CMT 1 was associated with freedom of IMI while CMT ≥2 was associated with IMI. Indirect measurement of SCC by CMT was well correlated with SCC measured by DCC. Conclusions According to the results, SCC measured with CMT or DCC can predict udder infection in goats, and CMT can be used as a

  14. Broadband Direct UVA irradiance measurement for clear skies evaluated using a smartphone

    International Nuclear Information System (INIS)

    Igoe, D.; Parisi, A.V.

    2015-01-01

    UVA wavelengths (320-400 nm) have been implicated in recent studies to contribute to melanoma induction and skin photo-aging in humans and damage to plants. The use of smartphones in UVA observations is a way to supplement measurements made by traditional radiometric and spectro-radiometric technology. Although the smartphone image sensor is not capable of determining broadband UVA irradiances, these can be reconstructed from narrowband irradiances, which the smartphone, with narrowband and neutral density filters, can quantify with discrepancies not exceeding 5 %. Three models that reconstruct direct broadband clear sky UVA were developed from narrowband irradiances derived from smartphone image sensor pixel data with coefficients of determination of between 0.97 and 0.99. Reasonable accuracy and precision in determining the direct broadband UVA was maintained for observations made with solar zenith angles as high as 70 deg. . The developed method has the potential to increase the uptake of the measurement of broadband UVA irradiances. (authors)

  15. Direct measurement of the pulse duration and frequency chirp of seeded XUV free electron laser pulses

    Science.gov (United States)

    Azima, Armin; Bödewadt, Jörn; Becker, Oliver; Düsterer, Stefan; Ekanayake, Nagitha; Ivanov, Rosen; Kazemi, Mehdi M.; Lamberto Lazzarino, Leslie; Lechner, Christoph; Maltezopoulos, Theophilos; Manschwetus, Bastian; Miltchev, Velizar; Müller, Jost; Plath, Tim; Przystawik, Andreas; Wieland, Marek; Assmann, Ralph; Hartl, Ingmar; Laarmann, Tim; Rossbach, Jörg; Wurth, Wilfried; Drescher, Markus

    2018-01-01

    We report on a direct time-domain measurement of the temporal properties of a seeded free-electron laser pulse in the extreme ultraviolet spectral range. Utilizing the oscillating electromagnetic field of terahertz radiation, a single-shot THz streak-camera was applied for measuring the duration as well as spectral phase of the generated intense XUV pulses. The experiment was conducted at FLASH, the free electron laser user facility at DESY in Hamburg, Germany. In contrast to indirect methods, this approach directly resolves and visualizes the frequency chirp of a seeded free-electron laser (FEL) pulse. The reported diagnostic capability is a prerequisite to tailor amplitude, phase and frequency distributions of FEL beams on demand. In particular, it opens up a new window of opportunities for advanced coherent spectroscopic studies making use of the high degree of temporal coherence expected from a seeded FEL pulse.

  16. Direct measurement of conformational strain energy in protofilaments curling outward from disassembling microtubule tips.

    Science.gov (United States)

    Driver, Jonathan W; Geyer, Elisabeth A; Bailey, Megan E; Rice, Luke M; Asbury, Charles L

    2017-06-19

    Disassembling microtubules can generate movement independently of motor enzymes, especially at kinetochores where they drive chromosome motility. A popular explanation is the 'conformational wave' model, in which protofilaments pull on the kinetochore as they curl outward from a disassembling tip. But whether protofilaments can work efficiently via this spring-like mechanism has been unclear. By modifying a previous assay to use recombinant tubulin and feedback-controlled laser trapping, we directly demonstrate the spring-like elasticity of curling protofilaments. Measuring their mechanical work output suggests they carry ~25% of the energy of GTP hydrolysis as bending strain, enabling them to drive movement with efficiency similar to conventional motors. Surprisingly, a β-tubulin mutant that dramatically slows disassembly has no effect on work output, indicating an uncoupling of disassembly speed from protofilament strain. These results show the wave mechanism can make a major contribution to kinetochore motility and establish a direct approach for measuring tubulin mechano-chemistry.

  17. A self-decoupling piezoresistive sensor for measuring microforce in horizontal and vertical directions

    International Nuclear Information System (INIS)

    Zhou, Jie; Rong, Weibin; Wang, Lefeng; Gao, Peng; Sun, Lining

    2016-01-01

    This paper presents the design, fabrication and calibration of a novel two-dimension microforce sensor with nano-Newton resolution. The sensor, mainly composed of a clamped–clamped beam (horizontal detecting beam), an overhanging beam (vertical detecting beam) and a half-folded beam, is highly sensitive to microforces in the horizontal (parallel to the probe of the designed sensor) and vertical (perpendicular to the wafer surface) directions. The four vertical sidewall surface piezoresistors (horizontal piezoresistors) and two surface piezoresistors (vertical piezoresistors) were fabricated to achieve the requirements of two-dimension microforce measurements. Combining the sensor structure with Wheatstone bridge configurations, the microforce decoupling among the x , y , and z direction can be realized. Accordingly, the sensor is capable of detecting microforces in the horizontal and vertical directions independently. The calibration results verified that the sensor sensitivities at room temperature are 210.58 V N −1 and 159.2 V N −1 in the horizontal and vertical directions, respectively. Additionally, the sensor’s corresponding force resolutions are estimated at 2 nN and 3 nN in theory, respectively. The sensor can be used to measure the contact force between manipulating tools and micro-objects, in fields such as microassembly and biological assays. (paper)

  18. The concordance of directly and indirectly measured built environment attributes and physical activity adoption

    Directory of Open Access Journals (Sweden)

    O'Connor Daniel P

    2011-07-01

    Full Text Available Background Physical activity (PA adoption is essential for obesity prevention and control, yet ethnic minority women report lower levels of PA and are at higher risk for obesity and its comorbidities compared to Caucasians. Epidemiological studies and ecologic models of health behavior suggest that built environmental factors are associated with health behaviors like PA, but few studies have examined the association between built environment attribute concordance and PA, and no known studies have examined attribute concordance and PA adoption. Purpose The purpose of this study was to associate the degree of concordance between directly and indirectly measured built environment attributes with changes in PA over time among African American and Hispanic Latina women participating in a PA intervention. Method Women (N = 410 completed measures of PA at Time 1 (T1 and Time 2 (T2; environmental data collected at T1 were used to compute concordance between directly and indirectly measured built environment attributes. The association between changes in PA and the degree of concordance between each directly and indirectly measured environmental attribute was assessed using repeated measures analyses. Results There were no significant associations between built environment attribute concordance values and change in self-reported or objectively measured PA. Self-reported PA significantly increased over time (F(1,184 = 7.82, p = .006, but this increase did not vary by ethnicity or any built environment attribute concordance variable. Conclusions Built environment attribute concordance may not be associated with PA changes over time among minority women. In an effort to promote PA, investigators should clarify specific built environment attributes that are important for PA adoption and whether accurate perceptions of these attributes are necessary, particularly among the vulnerable population of minority women.

  19. Assembly for the measurement of the most probable energy of directed electron radiation

    International Nuclear Information System (INIS)

    Geske, G.

    1987-01-01

    This invention relates to a setup for the measurement of the most probable energy of directed electron radiation up to 50 MeV. The known energy-range relationship with regard to the absorption of electron radiation in matter is utilized by an absorber with two groups of interconnected radiation detectors embedded in it. The most probable electron beam energy is derived from the quotient of both groups' signals

  20. Direct measurements of the 160.01-min oscillation in the solar radio brightness

    International Nuclear Information System (INIS)

    Efanov, V.A.; Moiseev, I.G.; Nesterov, N.S.

    1983-01-01

    Direct (nondifferential) brightness measurements of the quiet sun at lambda = 8.2 and 13.5 mm, corrected by the Bouguer law for absorption in the terrestrial atmosphere, confirm the presence of a 160.009 +- 0.002 min periodicity. At the two wavelengths the relative amplitudes are roughly-equal0.6 x 10 -3 , 1 x 10 -3 . Maximum radio brightness occurs at the phase when optical data indicate the photosphere radius is largest

  1. Direct Emissivity Measurements of Painted Metals for Improved Temperature Estimation During Laser Damage Testing

    Science.gov (United States)

    2014-03-27

    policy or position of the United States Air Force, the Department of Defense, or the United States Government . This material is declared a work of the...U.S. Government and is not subject to copyright protection in the United States. AFIT-ENP-14-M-43 DIRECT EMISSIVITY MEASUREMENTS OF PAINTED METALS FOR...Source The laser probe in use for this test is a Daylight Solutions Unicorn II quantum cascade laser operating at 3.77 µm. According to the laser

  2. Direct measurement of surface-state conductance by microscopic four-point probe method

    DEFF Research Database (Denmark)

    Hasegawa, S.; Shiraki, I.; Tanikawa, T.

    2002-01-01

    For in situ measurements of local electrical conductivity of well defined crystal surfaces in ultrahigh vacuum, we have developed microscopic four-point probes with a probe spacing of several micrometres, installed in a scanning-electron - microscope/electron-diffraction chamber. The probe...... is precisely positioned on targeted areas of the sample surface by using piezoactuators. This apparatus enables conductivity measurement with extremely high surface sensitivity, resulting in direct access to surface-state conductivity of the surface superstructures, and clarifying the influence of atomic steps...

  3. Feasibility study of direct spectra measurements for Thomson scattered signals for KSTAR fusion-grade plasmas

    Science.gov (United States)

    Park, K.-R.; Kim, K.-h.; Kwak, S.; Svensson, J.; Lee, J.; Ghim, Y.-c.

    2017-11-01

    Feasibility study of direct spectra measurements of Thomson scattered photons for fusion-grade plasmas is performed based on a forward model of the KSTAR Thomson scattering system. Expected spectra in the forward model are calculated based on Selden function including the relativistic polarization correction. Noise in the signal is modeled with photon noise and Gaussian electrical noise. Electron temperature and density are inferred using Bayesian probability theory. Based on bias error, full width at half maximum and entropy of posterior distributions, spectral measurements are found to be feasible. Comparisons between spectrometer-based and polychromator-based Thomson scattering systems are performed with varying quantum efficiency and electrical noise levels.

  4. Method of measuring directed electron velocities in flowing plasma using the incoherent regions of laser scattering

    International Nuclear Information System (INIS)

    Jacoby, B.A.; York, T.M.

    1979-02-01

    With the presumption that a shifted Maxwellian velocity distribution adequately describes the electrons in a flowing plasma, the details of a method to measure their directed velocity are described. The system consists of a ruby laser source and two detectors set 180 0 from each other and both set at 90 0 with respect to the incident laser beam. The lowest velocity that can be determined by this method depends on the electron thermal velocity. The application of this diagnostic to the measurement of flow velocities in plasma being lost from the ends of theta-pinch devices is described

  5. Direct measurement of the quantum state of the electromagnetic field in a superconducting transmission line

    International Nuclear Information System (INIS)

    Melo, F. de; Aolita, L.; Davidovich, L.; Toscano, F.

    2006-01-01

    We propose an experimental procedure to directly measure the state of an electromagnetic field inside a resonator, corresponding to a superconducting transmission line, coupled to a Cooper-pair box (CPB). The measurement protocol is based on the use of a dispersive interaction between the field and the CPB, and the coupling to an external classical field that is tuned to resonance with either the field or the CPB. We present a numerical simulation that demonstrates the feasibility of this protocol, which is within reach of present technology

  6. Direct measurement of gaseous activities by diffusion-in long proportional counter method

    International Nuclear Information System (INIS)

    Yoshida, M.; Yamamoto, T.; Wu, Y.; Aratani, T.; Uritani, A.; Mori, C.

    1993-01-01

    Direct measurement of gaseous activities by the diffusion-in long proportional counter method (DLPC method) was studied. The measuring time without end effect was estimated by observing the behavior of 37 Ar in the counter and was long enough to carry out the accurate activity measurement. The correction for wall effect was also examined on the basis of the measured and calculated correction factors. Among the tested gases of methane, P10 gas and propane, P10 gas was made clear to be a suitable counting gas for the DLPC method because of good diffusion properties and small wall effect. This method is quite effective for standardization of gaseous activities used for tracer experiments and calibration works of radioactive gas monitoring instruments. (orig.)

  7. Clustering of children's activity behaviour: the use of self-report versus direct measures

    Directory of Open Access Journals (Sweden)

    Tremblay Mark S

    2011-05-01

    Full Text Available Abstract While we concur with the objectives of the recent International Journal of Behavioural Nutrition and Physical Activity paper published by Jago and colleagues titled "Physical activity and sedentary behaviour typologies of 10-11 year olds", we feel that the results as currently presented do not support their conclusions. Though the authors created groups of children with dramatically different patterns of self-reported physical activity and sedentary behaviour, an inspection of the objectively measured accelerometry data shows little difference between the groups. Further, in at least one instance the difference between groups was of the opposite direction when using objective measures, as opposed to the self-report measures used in the published analysis. Thus, we caution the authors from making conclusions based on their self-report data, and propose that they re-analyze their data using their objectively measured data instead.

  8. Direct optical band gap measurement in polycrystalline semiconductors: A critical look at the Tauc method

    International Nuclear Information System (INIS)

    Dolgonos, Alex; Mason, Thomas O.; Poeppelmeier, Kenneth R.

    2016-01-01

    The direct optical band gap of semiconductors is traditionally measured by extrapolating the linear region of the square of the absorption curve to the x-axis, and a variation of this method, developed by Tauc, has also been widely used. The application of the Tauc method to crystalline materials is rooted in misconception–and traditional linear extrapolation methods are inappropriate for use on degenerate semiconductors, where the occupation of conduction band energy states cannot be ignored. A new method is proposed for extracting a direct optical band gap from absorption spectra of degenerately-doped bulk semiconductors. This method was applied to pseudo-absorption spectra of Sn-doped In 2 O 3 (ITO)—converted from diffuse-reflectance measurements on bulk specimens. The results of this analysis were corroborated by room-temperature photoluminescence excitation measurements, which yielded values of optical band gap and Burstein–Moss shift that are consistent with previous studies on In 2 O 3 single crystals and thin films. - Highlights: • The Tauc method of band gap measurement is re-evaluated for crystalline materials. • Graphical method proposed for extracting optical band gaps from absorption spectra. • The proposed method incorporates an energy broadening term for energy transitions. • Values for ITO were self-consistent between two different measurement methods.

  9. Proposal of traceability chain for direct measurements of radioactive contamination in Cuba

    International Nuclear Information System (INIS)

    Walwyn Salas, Gonzalo; Tamayo Garcia, Jose A.; Cornejo Diaz, Nestor

    2008-01-01

    The measurements of the radioactive surface contamination are common used to demonstrate the compliance with safety regulations at national level. It is mandatory that those measurements are traceable to national standards through the suitable calibration of the monitors used for survey. In Cuba, there is not a harmonized methodology for evaluation of contamination from direct measurements and no standardized calibration service for portable monitors is routinely provided to users. The Secondary Standard Dosimetry Laboratory of Cuba has recently established the calibration service of contamination monitors in terms of instrument efficiency using the reference sources of known emission rate per unit area in accordance with international normative ISO 8769. In the present paper, is proposed a traceable scheme of direct measurements of contamination that involve the calibration at the laboratory level using multi-source method and the evaluation of contaminations at user level in terms of activity per unit area. Some improvements from the previous single-source method of calibration are explained in order to support the advantages that offer the new chain for those measurements in the country. (author)

  10. Ovarian radiographic and direct measurements of Japanese Quail ( Coturnix coturnix japonica submitted to light restriction

    Directory of Open Access Journals (Sweden)

    M. Albuquerque

    Full Text Available ABSTRACT Often, in pet birds, any stimulus to lay eggs is unwanted in order to reduce reproductive diseases and disorders. The objectives of this study were: to determine the time necessary to promote ovary involution after an eight hour photoperiod using laying Japanese quails (Coturnix coturnix japonica; to connect the ovarian radiographic measurements with egg production; and to compare these measurements with direct ovary data obtained at necropsy. Birds were separated into three groups: 12h/24d (control group - 12h photoperiod for 24 days, 8h/24d and 8h/36d (8h photoperiod for 24 and 36 days. After euthanasia, all cadavers were x-rayed to measure ovary length and height. Birds were necropsied to measure ovarian length and weight. Results: radiographic ovary length demonstrated strong and positive correlation (r=0.96 with direct ovary length of all three groups; laying quails showed higher ovary height (p=0.025 and length (p=0.009 than non-laying quails; eight hours of artificial light per day promotes ovary length (p=0.025 and weight (p=0.009 reduction. Conclusions: radiography can estimate the ovary measure and indicate posture; an eight hour photoperiod of 24 days is not enough to promote ovarian regression, while the use of reduced photoperiod for 36 days promotes significant ovary involution.

  11. Measuring Dynamic Signals with Direct Sensor-to-Microcontroller Interfaces Applied to a Magnetoresistive Sensor

    Directory of Open Access Journals (Sweden)

    Ernesto Sifuentes

    2017-05-01

    Full Text Available This paper evaluates the performance of direct interface circuits (DIC, where the sensor is directly connected to a microcontroller, when a resistive sensor subjected to dynamic changes is measured. The theoretical analysis provides guidelines for the selection of the components taking into account both the desired resolution and the bandwidth of the input signal. Such an analysis reveals that there is a trade-off between the sampling frequency and the resolution of the measurement, and this depends on the selected value of the capacitor that forms the RC circuit together with the sensor resistance. This performance is then experimentally proved with a DIC measuring a magnetoresistive sensor exposed to a magnetic field of different frequencies, amplitudes, and waveforms. A sinusoidal magnetic field up to 1 kHz can be monitored with a resolution of eight bits and a sampling frequency of around 10 kSa/s. If a higher resolution is desired, the sampling frequency has to be lower, thus limiting the bandwidth of the dynamic signal under measurement. The DIC is also applied to measure an electrocardiogram-type signal and its QRS complex is well identified, which enables the estimation, for instance, of the heart rate.

  12. Measuring Dynamic Signals with Direct Sensor-to-Microcontroller Interfaces Applied to a Magnetoresistive Sensor.

    Science.gov (United States)

    Sifuentes, Ernesto; Gonzalez-Landaeta, Rafael; Cota-Ruiz, Juan; Reverter, Ferran

    2017-05-18

    This paper evaluates the performance of direct interface circuits (DIC), where the sensor is directly connected to a microcontroller, when a resistive sensor subjected to dynamic changes is measured. The theoretical analysis provides guidelines for the selection of the components taking into account both the desired resolution and the bandwidth of the input signal. Such an analysis reveals that there is a trade-off between the sampling frequency and the resolution of the measurement, and this depends on the selected value of the capacitor that forms the RC circuit together with the sensor resistance. This performance is then experimentally proved with a DIC measuring a magnetoresistive sensor exposed to a magnetic field of different frequencies, amplitudes, and waveforms. A sinusoidal magnetic field up to 1 kHz can be monitored with a resolution of eight bits and a sampling frequency of around 10 kSa/s. If a higher resolution is desired, the sampling frequency has to be lower, thus limiting the bandwidth of the dynamic signal under measurement. The DIC is also applied to measure an electrocardiogram-type signal and its QRS complex is well identified, which enables the estimation, for instance, of the heart rate.

  13. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  14. Ultrasound elastography: the new frontier in direct measurement of muscle stiffness.

    Science.gov (United States)

    Brandenburg, Joline E; Eby, Sarah F; Song, Pengfei; Zhao, Heng; Brault, Jeffrey S; Chen, Shigao; An, Kai-Nan

    2014-11-01

    The use of brightness-mode ultrasound and Doppler ultrasound in physical medicine and rehabilitation has increased dramatically. The continuing evolution of ultrasound technology has also produced ultrasound elastography, a cutting-edge technology that can directly measure the mechanical properties of tissue, including muscle stiffness. Its real-time and direct measurements of muscle stiffness can aid the diagnosis and rehabilitation of acute musculoskeletal injuries and chronic myofascial pain. It can also help monitor outcomes of interventions affecting muscle in neuromuscular and musculoskeletal diseases, and it can better inform the functional prognosis. This technology has implications for even broader use of ultrasound in physical medicine and rehabilitation practice, but more knowledge about its uses and limitations is essential to its appropriate clinical implementation. In this review, we describe different ultrasound elastography techniques for studying muscle stiffness, including strain elastography, acoustic radiation force impulse imaging, and shear-wave elastography. We discuss the basic principles of these techniques, including the strengths and limitations of their measurement capabilities. We review the current muscle research, discuss physiatric clinical applications of these techniques, and note directions for future research. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Measurements of Nitrogen Dioxide Total Column Amounts using a Brewer Double Spectrophotometer in Direct Sun Mode

    Science.gov (United States)

    Cede, Alexander; Herman, Jay; Richter, Andreas; Krotkov, Nickolay; Burrows, John

    2006-01-01

    NO2 column amounts were measured for the past 2 years at Goddard Space Flight Center, Greenbelt, Maryland, using a Brewer spectrometer in direct Sun mode. A new bootstrap method to calibrate the instrument is introduced and described. This technique selects the cleanest days from the database to obtain the solar reference spectrum. The main advantage for direct Sun measurements is that the conversion uncertainty from slant column to vertical column is negligible compared to the standard scattered light observations where it is typically on the order of 100% (2sigma) at polluted sites. The total 2sigma errors of the direct Sun retrieved column amounts decrease with solar zenith angle and are estimated at 0.2 to 0.6 Dobson units (DU, 1 DU approx. equal to 2.7 10(exp 16) molecules cm(exp -2)), which is more accurate than scattered light measurements for high NO2 amounts. Measured NO2 column amounts, ranging from 0 to 3 DU with a mean of 0.7 DU, show a pronounced daily course and a strong variability from day to day. The NO2 concentration typically increases from sunrise to noon. In the afternoon it decreases in summer and stays constant in winter. As expected from the anthropogenic nature of its source, NO2 amounts on weekends are significantly reduced. The measurements were compared to satellite retrievals from Scanning Image Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY). Satellite data give the same average NO2 column and show a seasonal cycle that is similar to the ground data in the afternoon. We show that NO2 must be considered when retrieving aerosol absorption properties, especially for situations with low aerosol optical depth.

  16. First direct mass measurements on nobelium and lawrencium with the Penning trap mass spectrometer SHIPTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Dworschak, Michael Gerhard

    2009-12-08

    The Penning trap mass spectrometer SHIPTRAP at GSI Darmstadt was set up for high-precision mass measurements of heavy radionuclides produced in fusion evaporation reactions and separated from the primary beam by the velocity filter SHIP. It consists of a gas stopping cell for the deceleration of the high energetic reaction products, an RFQ cooler and buncher for cooling and accumulation of the ions, and a double Penning trap system to perform mass measurements. The mass is determined by measuring the cyclotron frequency of the ion of interest in a strong homogeneous magnetic field and comparing it to the frequency of a well-known reference ion. With this method relative uncertainties in the order of 10{sup -8} can be achieved. Recently, mass measurements of the three nobelium isotopes {sup 252-254}No (Z=102) and the lawrencium isotope {sup 255}Lr (Z=103) were performed successfully. These were the first direct mass measurements of transuranium elements ever per- formed. The production rate of the atoms of interest was about one per second or less. The results of the measurements on nobelium confirm the previous mass values which were deduced from Q{sub {alpha}} values. In the case of {sup 255}Lr the mass excess value, which was previously only estimated from systematic trends, was for the first time directly measured. These results mark the first step in the exploration of the region of transuranium elements which is planned at SHIPTRAP. The main objective is to fix the endpoints of {alpha} decay chains which are originating from superheavy elements close to the predicted island of stability. (orig.)

  17. Direct measurement of the ballistic motion of a freely floating colloid in Newtonian and viscoelastic fluids.

    Science.gov (United States)

    Hammond, Andrew P; Corwin, Eric I

    2017-10-01

    A thermal colloid suspended in a liquid will transition from a short-time ballistic motion to a long-time diffusive motion. However, the transition between ballistic and diffusive motion is highly dependent on the properties and structure of the particular liquid. We directly observe a free floating tracer particle's ballistic motion and its transition to the long-time regime in both a Newtonian fluid and a viscoelastic Maxwell fluid. We examine the motion of the free particle in a Newtonian fluid and demonstrate a high degree of agreement with the accepted Clercx-Schram model for motion in a dense fluid. Measurements of the functional form of the ballistic-to-diffusive transition provide direct measurements of the temperature, viscosity, and tracer radius. We likewise measure the motion in a viscoelastic Maxwell fluid and find a significant disagreement between the theoretical asymptotic behavior and our measured values of the microscopic properties of the fluid. We observe a greatly increased effective mass for a freely moving particle and a decreased plateau modulus.

  18. Direct measurements of conventional and anisotropic magnetocaloric effect in binary RAl2 single crystals

    Science.gov (United States)

    Monteiro, J. C. B.; Gandra, F. G.

    2017-06-01

    We report on specific heat and magnetocaloric effect (MCE) measurements in single crystals of HoAl2, DyAl2, and TbAl2 measured by a heat flux technique using Peltier devices. Those compounds order ferromagnetically at 31 K, 61 K, and 106 K respectively, and present a spin reorientation transition (SRT) below TC. We study the dependence of the SRT with magnetic field and temperature by means of specific heat measurements performed in single crystals oriented at the [" separators="| 100 ], [" separators="| 110 ], and [" separators="| 111 ] directions with the aid of calculations using a simple model. We obtained the conventional MCE for HoAl2 and TbAl2 and also the anisotropic version of the effect obtained indirectly from the specific heat for TbAl2 and DyAl2. We also present the results for a direct determination of the anisotropic MCE for DyAl2 by measuring the heat flux generated by a rotation of the single crystal under constant field.

  19. Direct measurement of thermal conductivity in solid iron at planetary core conditions.

    Science.gov (United States)

    Konôpková, Zuzana; McWilliams, R Stewart; Gómez-Pérez, Natalia; Goncharov, Alexander F

    2016-06-02

    The conduction of heat through minerals and melts at extreme pressures and temperatures is of central importance to the evolution and dynamics of planets. In the cooling Earth's core, the thermal conductivity of iron alloys defines the adiabatic heat flux and therefore the thermal and compositional energy available to support the production of Earth's magnetic field via dynamo action. Attempts to describe thermal transport in Earth's core have been problematic, with predictions of high thermal conductivity at odds with traditional geophysical models and direct evidence for a primordial magnetic field in the rock record. Measurements of core heat transport are needed to resolve this difference. Here we present direct measurements of the thermal conductivity of solid iron at pressure and temperature conditions relevant to the cores of Mercury-sized to Earth-sized planets, using a dynamically laser-heated diamond-anvil cell. Our measurements place the thermal conductivity of Earth's core near the low end of previous estimates, at 18-44 watts per metre per kelvin. The result is in agreement with palaeomagnetic measurements indicating that Earth's geodynamo has persisted since the beginning of Earth's history, and allows for a solid inner core as old as the dynamo.

  20. Indirect and direct measurement of thermal neutron acceleration by inelastic scattering on the 177Lu isomer

    International Nuclear Information System (INIS)

    Belier, G.; Roig, O.; Meot, V.; Daugas, J.M.; Aupiais, J.; Jutier, Ch.; Le Petit, G.; Veyssiere, Ch.

    2008-01-01

    When neutrons interact with isomers, these isomers can de-excite and in such a reaction the outgoing neutron has an energy greater than the in-going one. This process is referred as Inelastic Neutron Acceleration or Super-elastic Scattering. Up to now this process was observed for only two nucleus, 152m Eu and 180m Hf by measuring the number of fast neutrons produced by isomeric targets irradiated with thermal neutrons. In these experiments the energies of the accelerated neutrons were not measured. This report presents an indirect measurement of inelastic neutron acceleration on 177m Lu, based on the burn-up and the radiative capture cross sections measurements. Since at thermal energies the inelastic scattering and the radiative capture are the only processes that contribute to the isomer burn-up, the inelastic cross section can be deduced from the difference between the two measured quantities. Applying this method for the 177 Lu isomer with different neutron fluxes we obtained a value of (257 ± 50) barns (for a temperature of 323 K) and determined that there is no integral resonance for this process. In addition the radiative capture cross section on 177g Lu was measured with a much better accuracy than the accepted value. Since the acceleration cross section is quite high, a direct measurement of this process was undertaken, sending thermal neutrons and measuring the fast neutrons. The main goal now is to measure the outgoing neutron energies in order to identify the neutron transitions in the exit channel. In particular the K conservation question can be addressed by such a measurement. (author)

  1. Prospects for direct neutron capture measurements on s-process branching point isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, C.; Lerendegui-Marco, J.; Quesada, J.M. [Universidad de Sevilla, Dept. de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Domingo-Pardo, C. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Kaeppeler, F. [Karlsruhe Institute of Technology, Institut fuer Kernphysik, Karlsruhe (Germany); Palomo, F.R. [Universidad de Sevilla, Dept. de Ingenieria Electronica, Sevilla (Spain); Reifarth, R. [Goethe-Universitaet Frankfurt am Main, Frankfurt am Main (Germany)

    2017-05-15

    The neutron capture cross sections of several unstable key isotopes acting as branching points in the s-process are crucial for stellar nucleosynthesis studies, but they are very challenging to measure directly due to the difficult production of sufficient sample material, the high activity of the resulting samples, and the actual (n, γ) measurement, where high neutron fluxes and effective background rejection capabilities are required. At present there are about 21 relevant s-process branching point isotopes whose cross section could not be measured yet over the neutron energy range of interest for astrophysics. However, the situation is changing with some very recent developments and upcoming technologies. This work introduces three techniques that will change the current paradigm in the field: the use of γ-ray imaging techniques in (n, γ) experiments, the production of moderated neutron beams using high-power lasers, and double capture experiments in Maxwellian neutron beams. (orig.)

  2. Plasma dynamics near critical density inferred from direct measurements of laser hole boring

    Science.gov (United States)

    Gong, Chao; Tochitsky, Sergei Ya.; Fiuza, Frederico; Pigeon, Jeremy J.; Joshi, Chan

    2016-06-01

    We have used multiframe picosecond optical interferometry to make direct measurements of the hole boring velocity, vHB, of the density cavity pushed forward by a train of C O2 laser pulses in a near critical density helium plasma. As the pulse train intensity rises, the increasing radiation pressure of each pulse pushes the density cavity forward and the plasma electrons are strongly heated. After the peak laser intensity, the plasma pressure exerted by the heated electrons strongly impedes the hole boring process and the vHB falls rapidly as the laser pulse intensity falls at the back of the laser pulse train. A heuristic theory is presented that allows the estimation of the plasma electron temperature from the measurements of the hole boring velocity. The measured values of vHB, and the estimated values of the heated electron temperature as a function of laser intensity are in reasonable agreement with those obtained from two-dimensional numerical simulations.

  3. Directivity of Spherical Polyhedron Sound Source Used in Near-Field HRTF Measurements

    International Nuclear Information System (INIS)

    Yu Guang-Zheng; Xie Bo-Sun; Rao Dan

    2010-01-01

    The omnidirectional character is one of important requirements for the sound source used in near-field head-related transfer function (HRTF) measurements. Based on the analysis on the radiation sound pressure and directivity character of various spherical polyhedron sound sources, a spherical dodecahedral sound source with radius of 0.035m is proposed and manufactured. Theoretical and measured results indicate that the sound source is approximately omnidirectional below the frequency of 8 kHz. In addition, the sound source has reasonable magnitude response from 350Hz to 20kHz and linear phase characteristics. Therefore, it is suitable for the near-field HRTF measurements. (fundamental areas of phenomenology(including applications))

  4. Detection system qualification for direct measurement of thyroid internal contamination by radioiodine

    International Nuclear Information System (INIS)

    Tiberi, V.; Battisti, P.; Gualdrini, G.

    1999-01-01

    The work deals with a detection system qualification for direct measurements of thyroid internal contamination by radioiodine. The isotopes 131 I and 125 I are the most frequently used in nuclear medicine. Because of their volatility they are very dangerous for thyroid contamination by inhalation. The system has been projected to be easily and fast used and above all transportable where the control is necessary. These characteristic make it able to realise supervision programs of internal contamination by radioiodine. In fact due the very high control frequencies (each 15 days for 131 I), these programs are usually very expensive and demanding when they are executed in external measurement laboratories. The following steps are described: devices presentation, calculation of energy and efficiency parameters, minimum detectable activity, time system reliability, best operative conditions in the measurements. At the end an application example of the system is reported [it

  5. Direct dose measurement on patient during percutaneous coronary intervention procedures using radiophotoluminescence glass dosimeters

    International Nuclear Information System (INIS)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Sato, Tadaya; Oosaka, Hajime; Toyoshima, Hideto; Zuguchi, Masayuki; Abe, Yoshihisa

    2017-01-01

    The purpose of this research was to measure accurate patient entrance skin dose and maximum skin absorbed dose (MSD) to prevent radiation skin injuries in percutaneous coronary interventions (PCIs). We directly measured the MSD on 50 PCIs by using multiple radiophotoluminescence glass dosimeters and a modified dosimetry gown. Also, we analysed the correlation between the MSD and indirect measurement parameters, such as fluoroscopic time (FT), dose-area product (DAP) and cumulative air kerma (C-AK). There were very strong correlations between MSD and FT, DAP and C-AK, with the correlation between MSD and C-AK being the strongest (r = 0.938). In conclusion, the regression lines using MSD as an outcome value (y) and C-AK as predictor variables (x) were y = 1.12x (R"2 = 0.880). From the linear regression equation, MSD is estimated to be ∼1.12 times that of C-AK in real time. (authors)

  6. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    Science.gov (United States)

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  7. Evidence for production of single top quarks and first direct measurement of |Vtb|

    International Nuclear Information System (INIS)

    Abazov, V.M.; Abbott, B.; Abolins, M.; Acharya, B.S.; Adams, M.; Adams, T.; Aguilo, E.; Ahn, S.H.; Ahsan, M.; Alexeev, G.D.; Alkhazov, G.; Alton, A.; Alverson, G.; Alves, G.A.; Anastasoaie, M.; Ancu, L.S.; Andeen, T.; Anderson, S.; Andrieu, B.; Anzelc, M.S.; Arnoud, Y.

    2006-01-01

    The D0 Collaboration presents first evidence for the production of single top quarks at the Fermilab Tevatron p(bar p) collider. Using a 0.9 fb -1 dataset, we apply a multivariate analysis to separate signal from background and measure σ(p(bar p) → tb + X, tqb + X) = 4.9 ± 1.4 pb. The probability to measure a cross section at this value or higher in the absence of signal is 0.035%, corresponding to a 3.4 standard deviation significance. We use the cross section measurement to directly determine the CKM matrix element that describes the W tb coupling and find 0.68 tb | (le) 1 at 95% C.L

  8. Evaluation of the dose committed as based on direct measurements with the Whole Body Counter

    International Nuclear Information System (INIS)

    Meladani, C.; Castellani, C.M.; Battisti, P.; Tarroni, G.

    1989-01-01

    During normal working activities or in accidental situations, when the introduction of radioactive gamma emitters is non-negligible amount, accurate determination of effective committed dose equivalent based on direct measurements of the internal contamination cannot be avoided. Internal contamination measurements carried out by Whole Body Counter and the application of dosimetric and metabolic models as proposed by ICRP Publication 30 allow the intakes and committed dose equivalents to be evaluated. This paper presents the evaluation methodologies of committed dose equivalent both for istantaneous and extended contaminations. Furthermore, some advice about useful, opportune modes and time uncertainties due to the application of generalized models to particular situations, are also reported. On the basis of the Chernobyl experience, the general criteria for the chice and size of homogeneous groups of individuals to be measured, are finally submitted with a view to collecting the necessary radiation protection information concerning contamination of a part or a whole population

  9. Fractional Flow Reserve Measurement by Coronary Computed Tomography Angiography: A Review with Future Directions

    Directory of Open Access Journals (Sweden)

    Asim Rizvi

    2016-12-01

    Full Text Available Invasive fractional flow reserve (FFR measurement is currently the gold standard for coronary intervention. FFR measurement by coronary computed tomography angiography (FFRCT is a novel and promising imaging technology that permits noninvasive assessment of physiologically significant coronary lesions. FFRCT is capable of combining the anatomic information provided by coronary computed tomography angiography with computational fluid dynamics to compute FFR. To date, several studies have reported the diagnostic performance of FFRCT compared with invasive FFR measurement as the reference standard. Further studies are now being implemented to determine the clinical feasibility and economic implications of FFRCT techniques. This article provides an overview and discusses the available evidence as well as potential future directions of FFRCT.

  10. Reliability of an analysis method for measuring diaphragm excursion by means of direct visualization with videofluoroscopy.

    Science.gov (United States)

    Yi, Liu C; Nascimento, Oliver A; Jardim, José R

    2011-06-01

    The purpose of this study was to verify the reproducibility between two different observers of an analysis method for diaphragmatic displacement measurements using direct visualization with videofluoroscopy. 29 mouth breathing children aged 5 to 12 years from both genders were analyzed. The diaphragmatic displacement evaluation was divided in three parts: videofluoroscopy with VHS recording in standing, sitting, and dorsal positions; digitalization of the images; and measurement of the distance between diaphragmatic domes during a breathing cycle using Adobe Photoshop 5.5 and Adobe Premiere PRO 6.5 software. The intraclass correlation coefficients presented excellent reproducibility in all positions, with coefficients always above 0.94. Mean of the measurements of the diaphagramatic domes displacement done by the two observers were similar (Phealthcare professionals. Copyright © 2010 SEPAR. Published by Elsevier Espana. All rights reserved.

  11. Magnitude and directional measures of water and Cr(VI) fluxes by passive flux meter.

    Science.gov (United States)

    Campbell, Timothy J; Hatfield, Kirk; Klammler, Harald; Annable, Michael D; Rao, P S C

    2006-10-15

    A new configuration of the passive fluxmeter (PFM) is presented that provides for simultaneous measurements of both the magnitude and the direction of ambient groundwater specific discharge qo and Cr(VI) mass flux J(Cr). The PFM is configured as a cylindrical unit with an interior divided into a center section and three outer sectors, each packed with a granular anion exchange resin having high sorption capacity for the Cr(VI) oxyanions CrO4(2-) and HCrO4-. The sorbent in the center section is preloaded with benzoate as the "resident" tracer. Laboratory experiments were conducted in which PFMs were placed in porous packed bed columns, through which was passed a measured volume of synthetic groundwater containing Cr(VI). During the deployment period, some of the resident tracer is depleted while the Cr(VI) is sorbed. The resin was then removed from the four sectors separately and extracted to determine the "captured" mass of Cr(VI) and the residual mass of the resident tracer in each. Cumulative specific discharge, q0t, values were assessed using the residual mass of benzoate retained in the center section. The direction of this discharge theta was ascertained from the mass distribution of benzoate intercepted and retained in the outer three sections of the PFM. Cumulative chromium fluxes, J(Cr)t, were quantified using the total Cr(VI) mass intercepted and retained on the PFM. Experiments produced an average measurement error for direction theta of 3 degrees +/- 14 degrees, while the average measurement errors for q0 and J(Cr) were, respectively, -8% +/- 15% and -12% +/- 23%. Results demonstrate the potential utility of the new PFM configuration for characterizing groundwater and contaminant fluxes.

  12. Deep-water measurements of container ship radiated noise signatures and directionality.

    Science.gov (United States)

    Gassmann, Martin; Wiggins, Sean M; Hildebrand, John A

    2017-09-01

    Underwater radiated noise from merchant ships was measured opportunistically from multiple spatial aspects to estimate signature source levels and directionality. Transiting ships were tracked via the Automatic Identification System in a shipping lane while acoustic pressure was measured at the ships' keel and beam aspects. Port and starboard beam aspects were 15°, 30°, and 45° in compliance with ship noise measurements standards [ANSI/ASA S12.64 (2009) and ISO 17208-1 (2016)]. Additional recordings were made at a 10° starboard aspect. Source levels were derived with a spherical propagation (surface-affected) or a modified Lloyd's mirror model to account for interference from surface reflections (surface-corrected). Ship source depths were estimated from spectral differences between measurements at different beam aspects. Results were exemplified with a 4870 and a 10 036 twenty-foot equivalent unit container ship at 40%-56% and 87% of service speeds, respectively. For the larger ship, opportunistic ANSI/ISO broadband levels were 195 (surface-affected) and 209 (surface-corrected) dB re 1 μPa 2 1 m. Directionality at a propeller blade rate of 8 Hz exhibited asymmetries in stern-bow (<6 dB) and port-starboard (<9 dB) direction. Previously reported broadband levels at 10° aspect from McKenna, Ross, Wiggins, and Hildebrand [(2012b). J. Acoust. Soc. Am. 131, 92-103] may be ∼12 dB lower than respective surface-affected ANSI/ISO standard derived levels.

  13. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  14. Directed Forgetting in Direct and Indirect Tests of Memory: Seeking Evidence of Retrieval Inhibition Using Electrophysiological Measures

    Science.gov (United States)

    Van Hooff, Johanna C.; Whitaker, T. Aisling; Ford, Ruth M.

    2009-01-01

    We investigated whether directed forgetting as elicited by the item-cueing method results solely from "differential rehearsal" of to-be-remembered vs. to-be-forgotten words or, additionally, from "inhibitory" processes that actively impair retrieval of to-be-forgotten words. During study, participants (N = 24) were instructed to remember half of a…

  15. Measurement of the beta-gamma directional correlation of the transition 46Sc→46Ti

    International Nuclear Information System (INIS)

    Krexner, G.

    1978-01-01

    Measuring the forward - backward asymmetry of the direction of gamma quanta with respect to the direction of a preceding beta particle emission is one of the methods which have been developed over the past twenty years to investigate parity admixtures in nuclear states. Both theoretical calculations and experiments using this method yield very small values for the considered effect. Moreover the accuracy is limited for statistical reasons. Hence there exists a fundamental interest in proving the experimental arrangement to be free of systematic errors. The subject of this work is an experiment checking a six - detector apparatus which has been used to investigate the beta - gamma directional correlation in the decay 203 Hg→ 203 Tl. For the control measurement the transition 46 Sc→ 46 Ti was chosen. The asymmetry coefficient should yield zero and thus furnish evidence of the absence of systematic errors. The necessary 46 Sc source had to meet very restricting requirements. The feasibility of various methods for producing radioactive samples was reviewed; finally a specially designed high vacuum evaporation plant was constructed. The concept of this device and the preparation of the source are dealt with in detail. A preliminary result of the control experiment is given. However, at present a definite interpretation of the obtained values is not possible. (author)

  16. A novel method for direct measurement of complement convertases activity in human serum.

    Science.gov (United States)

    Blom, A M; Volokhina, E B; Fransson, V; Strömberg, P; Berghard, L; Viktorelius, M; Mollnes, T E; López-Trascasa, M; van den Heuvel, L P; Goodship, T H; Marchbank, K J; Okroj, M

    2014-10-01

    Complement convertases are enzymatic complexes that play a central role in sustaining and amplification of the complement cascade. Impairment of complement function leads directly or indirectly to pathological conditions, including higher infection rate, kidney diseases, autoimmune- or neurodegenerative diseases and ischaemia-reperfusion injury. An assay for direct measurement of activity of the convertases in patient sera is not available. Existing assays testing convertase function are based on purified complement components and, thus, convertase formation occurs under non-physiological conditions. We designed a new assay, in which C5 blocking compounds enabled separation of the complement cascade into two phases: the first ending at the stage of C5 convertases and the second ending with membrane attack complex formation. The use of rabbit erythrocytes or antibody-sensitized sheep erythrocytes as the platforms for convertase formation enabled easy readout based on measurement of haemolysis. Thus, properties of patient sera could be studied directly regarding convertase activity and membrane attack complex formation. Another advantage of this assay was the possibility to screen for host factors such as C3 nephritic factor and other anti-complement autoantibodies, or gain-of-function mutations, which prolong the half-life of complement convertases. Herein, we present proof of concept, detailed description and validation of this novel assay. © 2014 British Society for Immunology.

  17. Measurement of plant and soil water isotope composition by direct equilibration methods

    Science.gov (United States)

    Scrimgeour, C. M.

    1995-11-01

    Water contained in plant and soil samples can be analysed for 2H and 18O content by direct equilibration while contained within the sample matrix. Methods for this are described and compared with the commonly used azeotropic distillation of samples before isotope analysis. For δ18O, direct equilibration with CO 2 gives results in good agreement with azeotropic distillation, i.e. within 0.5%o at natural abundance. Direct equilibration is a practical method for individual twig samples containing less than 0.5 ml of water, and offers significant operator time savings compared with azeotropic distillation. Batches of up to 100 samples can be prepared in less time than required for a single azeotropic distillation, and analysis by automated continuous-flow isotope ratio mass spectrometry after equilibration for 3 days again requires a minimum of operator time. Complete equilibration of plant water with H 2 for δ2H measurement occurs only after the plant material has been heated to 100°C under vacuum. The method described here is barely precise enough for natural abundance measurements ( δ 2H ± 15‰ ) but is well suited to field tracer studies with deuterium oxide.

  18. Measuring Broadband IR Irradiance in the Direct Solar Beam and Recent Developments

    Energy Technology Data Exchange (ETDEWEB)

    Reda, Ibrahim; Andreas, Afshin; Dooraghi, Mike; Habte, Aron; Sengupta, Manajit; Kutchenreiter, Mark

    2016-12-14

    Solar and atmospheric science radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference which is maintained by Absolute Cavity Radiometers (ACRs). An ACR is an open cavity with no window, developed to measure the extended broadband spectrum of the terrestrial direct solar beam irradiance that extends beyond the ultraviolet and infrared bands; i.e. below 0.2 um and above 50 um, respectively. On the other hand, the pyranometers and pyrheliometers were developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to the spectral range of approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers, which measure the atmospheric longwave irradiance, are also used for solar and atmospheric science applications and calibrated with traceability to a consensus reference, yet they are calibrated during nighttime only, because no consensus reference has been established for the daytime longwave irradiance. This poster describes a method to measure the broadband longwave irradiance in the terrestrial direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The described method is used to measure the irradiance from sunrise to sunset; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 with an estimated uncertainty of 1.5 Wm-2, for a solar zenith angle range from 80 degrees to 16 degrees, respectively. Recent development shows that there is greater than 1.1 percent bias in measuring shortwave solar irradiance.

  19. Direct and quadrature inductances measurement of the permanent magnetic linear synchronous machines

    Energy Technology Data Exchange (ETDEWEB)

    Li Liyi [Electrical Engineering Dept./Harbin Institute of Technology, Harbin 150000 (China); Hong Junjie, E-mail: wizard0663@126.co [School of Engineering/Sun Yat-Sen University, Guangzhou 510006 (China); Wu Hongxing; Kou Baoquan; Liu Rizhong [Electrical Engineering Dept./Harbin Institute of Technology, Harbin 150000 (China)

    2011-05-15

    Research highlights: {yields} The d- and q-axis inductances are derived theoretically. {yields} The new measurement principle of the d- and q-axis inductances is analyzed. {yields} A corresponding measuring circuit is developed. {yields} Measurement results match those of the FEM well. -- Abstract: Permanent magnetic linear synchronous machines (PMLSMs) are playing a more important role either in transportation systems or magnetic launch systems, for the excellent advantages. It is indispensable to high performance controllers that some machine parameters are known such as the direct axis (d-axis) and quadrature axis (q-axis) inductances. In this paper, self and mutual inductances of the three-phase winding are deduced by basic electric machinery theory, and the measured inductances are analyzed since the mutual inductances and the corresponding terminals among three-phase windings are changing as different phase winding is concerned. The d- and q-axis inductances are measured with the designed circuit, and the experimental measurement method is validated by the comparison between the experimental and finite element method (FEM) results.

  20. Direct and quadrature inductances measurement of the permanent magnetic linear synchronous machines

    International Nuclear Information System (INIS)

    Li Liyi; Hong Junjie; Wu Hongxing; Kou Baoquan; Liu Rizhong

    2011-01-01

    Research highlights: → The d- and q-axis inductances are derived theoretically. → The new measurement principle of the d- and q-axis inductances is analyzed. → A corresponding measuring circuit is developed. → Measurement results match those of the FEM well. -- Abstract: Permanent magnetic linear synchronous machines (PMLSMs) are playing a more important role either in transportation systems or magnetic launch systems, for the excellent advantages. It is indispensable to high performance controllers that some machine parameters are known such as the direct axis (d-axis) and quadrature axis (q-axis) inductances. In this paper, self and mutual inductances of the three-phase winding are deduced by basic electric machinery theory, and the measured inductances are analyzed since the mutual inductances and the corresponding terminals among three-phase windings are changing as different phase winding is concerned. The d- and q-axis inductances are measured with the designed circuit, and the experimental measurement method is validated by the comparison between the experimental and finite element method (FEM) results.

  1. Direct measurement of radioactive carbon in Vietnamese vodkas by Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Hattori, Takamitsu

    2014-01-01

    From the view point of applying to laboratory exercise of radioactivity measurement by a Liquid Scintillation Counter (LSC), Vietnamese vodkas have specific features as measurement samples, for example, they are colorless, have high ethanol content, and only very few organic materials are included. Investigation was made to make sure that the Vietnamese vodkas are appropriate or not as a measurement sample for the LSC exercise. Direct measurements of 14 C without any chemical pre-treatment were made on both radioactive concentrations and specific activities of three kinds of Vietnamese vodka and also pure ethanol reagent. The LSC measurements reveal that estimated 14 C concentration is proportional to ethanol content in samples and that specific activity of 14 C shows good agreement among the Vietnamese vodkas and pure ethanol, as well as the reference value of 0.25 Bq/g of Carbon. Thus the conclusion is derived that the Vietnamese vodkas can be applied with high accuracy to the LSC exercise as measurement samples. (author)

  2. Direct measurement of wall shear stress in a reattaching flow with a photonic sensor

    International Nuclear Information System (INIS)

    Ayaz, U K; Ioppolo, T; Ötügen, M V

    2013-01-01

    Wall shear stress measurements are carried out in a planar backward-facing step flow using a micro-optical sensor. The sensor is essentially a floating element system and measures the shear stress directly. The transduction method to measure the floating element deflection is based on the whispering gallery optical mode (WGM) shifts of a dielectric microsphere. This method is capable of measuring floating element displacements of the order of a nanometer. The floating element surface is circular with a diameter of ∼960 µm, which is part of a beam that is in contact with the dielectric microsphere. The sensor is calibrated for shear stress as well as pressure sensitivity yielding 7.3 pm Pa −1 and 0.0236 pm Pa −1 for shear stress and pressure sensitivity, respectively. Hence, the contribution by the wall pressure is less than two orders of magnitude smaller than that of shear stress. Measurements are made for a Reynolds number range of 2000–5000 extending to 18 step heights from the step face. The results are in good agreement with those of earlier reports. An analysis is also carried out to evaluate the performance of the WGM sensor including measurement sensitivity and bandwidth. (paper)

  3. Development of a direct push based in-situ thermal conductivity measurement system

    Science.gov (United States)

    Chirla, Marian Andrei; Vienken, Thomas; Dietrich, Peter; Bumberger, Jan

    2016-04-01

    Heat pump systems are commonly utilized in Europe, for the exploitation of the shallow geothermal potential. To guarantee a sustainable use of the geothermal heat pump systems by saving resources and minimizing potential negative impacts induced by temperature changes within soil and groundwater, new geothermal exploration methods and tools are required. The knowledge of the underground thermal properties is a necessity for a correct and optimum design of borehole heat exchangers. The most important parameter that indicates the performance of the systems is thermal conductivity of the ground. Mapping the spatial variability of thermal conductivity, with high resolution in the shallow subsurface for geothermal purposes, requires a high degree of technical effort to procure adequate samples for thermal analysis. A collection of such samples from the soil can disturb sample structure, so great care must be taken during collection to avoid this. Factors such as transportation and sample storage can also influence measurement results. The use of technologies like Thermal Response Test (TRT) require complex mechanical and electrical systems for convective heat transport in the subsurface and longer monitoring times, often three days. Finally, by using thermal response tests, often only one integral value is obtained for the entire coupled subsurface with the borehole heat exchanger. The common thermal conductivity measurement systems (thermal analyzers) can perform vertical thermal conductivity logs only with the aid of sample procurement, or by integration into a drilling system. However, thermal conductivity measurements using direct push with this type of probes are not possible, due to physical and mechanical limitations. Applying vertical forces using direct push technology, in order to penetrate the shallow subsurface, can damage the probe and the sensors systems. The aim of this study is to develop a new, robust thermal conductivity measurement probe, for direct

  4. 2D temperature field measurement in a direct-injection engine using LIF technology

    Science.gov (United States)

    Liu, Yongfeng; Tian, Hongsen; Yang, Jianwei; Sun, Jianmin; Zhu, Aihua

    2011-12-01

    A new multi-spectral detection strategy for temperature laser- induced- fluorescence (LIF) 2-D imaging measurements is reported for high pressure flames in high-speed diesel engine. Schematic of the experimental set-up is outlined and the experimental data on the diesel engine is summarized. Experiment injection system is a third generation Bosch high-pressure common rail featuring a maximum pressure of 160MPa. The injector is equipped with a six-hole nozzle, where each hole has a diameter of 0.124 mm. and slightly offset to the center of the cylinder axis to allow a better cooling of the narrow bridge between the exhaust valves. The measurement system includes a blower, which supplied the intake flow rate, and a prototype single-valve direct injection diesel engine head modified to lay down the swirled-type injector. 14-bit digital CCD cameras are employed to achieve a greater level of accuracy in comparison to the results of previous measurements. The temperature field spatial distributions in the cylinder for different crank angle degrees are carried out in a single direct-injection diesel engine.

  5. Using alternative or direct anthropometric measurements to assess risk for malnutrition in nursing homes.

    Science.gov (United States)

    Lorini, Chiara; Collini, Francesca; Castagnoli, Mariangela; Di Bari, Mauro; Cavallini, Maria Chiara; Zaffarana, Nicoletta; Pepe, Pasquale; Lucenteforte, Ersilia; Vannacci, Alfredo; Bonaccorsi, Guglielmo

    2014-10-01

    The aim of this study was to use the Malnutrition Universal Screening Tool (MUST) to assess the applicability of alternative versus direct anthropometric measurements for evaluating the risk for malnutrition in older individuals living in nursing homes (NHs). We conducted a cross-sectional survey in 67 NHs in Tuscany, Italy. We measured the weight, standing height (SH), knee height (KH), ulna length (UL), and middle-upper-arm circumference of 641 NH residents. Correlations between the different methods for calculating body mass index (BMI; using direct or alternative measurements) were evaluated by the intraclass correlation coefficient and the Bland-Altman method; agreement in the allocation of participants to the same risk category was assessed by squared weighted kappa statistic and indicators of internal relative validity. The intraclass correlation coefficient for BMI calculated using KH was 0.839 (0.815-0.861), whereas those calculated by UL were 0.890 (0.872-0.905). The limits of agreement were ±6.13 kg/m(2) using KH and ±4.66 kg/m(2) using UL. For BMI calculated using SH, 79.9% of the patients were at low risk, 8.1% at medium risk, and 12.2% at high risk for malnutrition. The agreement between this classification and that obtained using BMI calculated by alternative measurements was "fair-good." When it is not possible to determine risk category by using SH, we suggest using the alternative measurements (primarily UL, due to its highest sensitivity) to predict the height and to compare these evaluations with those obtained by using middle-upper-arm-circumference to predict the BMI. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Direct measurement of fast transients by using boot-strapped waveform averaging

    Science.gov (United States)

    Olsson, Mattias; Edman, Fredrik; Karki, Khadga Jung

    2018-03-01

    An approximation to coherent sampling, also known as boot-strapped waveform averaging, is presented. The method uses digital cavities to determine the condition for coherent sampling. It can be used to increase the effective sampling rate of a repetitive signal and the signal to noise ratio simultaneously. The method is demonstrated by using it to directly measure the fluorescence lifetime from Rhodamine 6G by digitizing the signal from a fast avalanche photodiode. The obtained lifetime of 4.0 ns is in agreement with the known values.

  7. The direct heat measurement of mechanical energy storage metal-organic frameworks.

    Science.gov (United States)

    Rodriguez, Julien; Beurroies, Isabelle; Loiseau, Thierry; Denoyel, Renaud; Llewellyn, Philip L

    2015-04-07

    In any process, the heat exchanged is an essential property required in its development. Whilst the work related to structural transitions of some flexible metal-organic frameworks (MOFs) has been quantified and linked with potential applications such as molecular springs or shock absorbers, the heat related to such transitions has never been directly measured. This has now been carried out with MIL-53(Al) using specifically devised calorimetry experiments. We project the importance of these heats in devices such as molecular springs or dampers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Detection of solar radio brightness oscillations with 160.01-min period from direct measurements

    International Nuclear Information System (INIS)

    Efanov, V.A.; Moiseev, I.G.; Nesterov, N.S.

    1983-01-01

    It is shown that direct measurements of the quiet Sun brightness at 8.2 and 13.5 mm wavelengths corrected for extinction in the Earth atmosphere by means of the Bouguer law reveal the 160.01-min periodic component. The relative amplitudes of variations are of approximately 6x10 -4 at the shorter wavelength and of 10 -3 at the longer one. The brightness maximum coincides with the phase of the maximal radius of the photosphere as derived from the optical data

  9. Binaural loudness for artificial-head measurements in directional sound fields

    DEFF Research Database (Denmark)

    Sivonen, Ville Pekka; Ellermeier, Wolfgang

    2008-01-01

    The effect of the sound incidence angle on loudness was investigated for fifteen listeners who matched the loudness of sounds coming from five different incidence angles in the horizontal plane to that of the same sound with frontal incidence. The stimuli were presented via binaural synthesis...... by using head-related transfer functions measured for an artificial head. The results, which exhibited marked individual differences, show that loudness depends on the direction from which a sound reaches the listener. The average results suggest a relatively simple rule for combining the two signals...... at the ears of an artificial head for binaural loudness predictions....

  10. Direct measurement of oxygen in brown coals and carbochemical products by means of fast neutron analysis

    International Nuclear Information System (INIS)

    Raeppel, P.; Foerster, H.

    1990-01-01

    Analyses of elemental oxygen by means of fast neutron activation permit high-accuracy measurements of oxygen concentrations in East German brown coal; this applies to run-of-mine brown coal as well as to demineralized brown coal. The relative error was 4% in the first case and 2% in the latter case. Pre-washing with 1n ammonium acetate solution permits direct analyses of the oxygen bonded to the coal minerals. The method is applicable to other carbonaceous materials, e.g. coal ashes, solid hydrogenation residues, cokes, coal extracts, asphaltenes, oils, etc., at oxygen concentrations of 1-50%. (orig.) [de

  11. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.; Smith, Casey; Ghoneim, Mohamed T.; Yu, Qingkai; Hussain, Muhammad Mustafa

    2013-01-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  12. Practical colorimeter for direct measurement of microplates in enzyme immunoassay systems.

    Science.gov (United States)

    Clem, T R; Yolken, R H

    1978-01-01

    A colorimeter capable of measuring results of enzyme-linked immunosorbent assay (ELISA) reactions directly in the wells of a microtiter plate is described. This colorimeter proved to be as accurate as a conventional spectrophotometer in assessing ELISA reactions, but had the advantage of not requiring transfer of the specimen to a separate chamber. With this colorimeter, 96 specimens can be read in approximately 5 min. A practical colorimeter such as this can make the use of ELISA tests more feasible for many laboratories.

  13. Direct measurement of sub-Debye-length attraction between oppositely charged surfaces.

    Science.gov (United States)

    Kampf, Nir; Ben-Yaakov, Dan; Andelman, David; Safran, S A; Klein, Jacob

    2009-09-11

    Using a surface force balance with fast video analysis, we have measured directly the attractive forces between oppositely charged solid surfaces (charge densities sigma(+), sigma(-)) across water over the entire range of interaction, in particular, at surface separations D below the Debye screening length lambda(S). At very low salt concentration we find a long-ranged attraction between the surfaces (onset ca. 100 nm), whose variation at D

  14. Direct measurement of the Ds branching fraction to φπ

    International Nuclear Information System (INIS)

    Bai, J.Z.; Bardon, O.; Blum, I.; Breakstone, A.; Burnett, T.; Chen, G.P.; Chen, H.F.; Chen, J.; Chen, S.J.; Chen, S.M.; Chen, Y.; Chen, Y.B.; Chen, Y.Q.; Cheng, B.S.; Cowan, R.F.; Cui, H.C.; Cui, X.Z.; Ding, H.L.; Du, Z.Z.; Dunwoodie, W.; Fan, X.L.; Fang, J.; Fero, M.; Gao, C.S.; Gao, M.L.; Gao, S.Q.; Gao, W.X.; Gratton, P.; Gu, J.H.; Gu, S.D.; Gu, W.X.; Gu, Y.F.; Guo, Y.N.; Han, S.W.; Han, Y.; Harris, F.A.; Hatanaka, M.; He, J.; He, K.R.; He, M.; Hitlin, D.G.; Hu, G.Y.; Hu, H.B.; Hu, T.; Hu, X.Q.; Huang, D.Q.; Huang, Y.Z.; Izen, J.M.; Jia, Q.P.; Jiang, C.H.; Jin, Y.; Jones, L.; Kang, S.H.; Kelsey, M.H.; Kim, B.K.; Lai, Y.F.; Lan, H.B.; Lang, P.F.; Lankford, A.; Li, F.; Li, J.; Li, P.Q.; Li, Q.; Li, R.B.; Li, W.; Li, W.D.; Li, W.G.; Li, X.; Li, X.N.; Lin, S.Z.; Liu, H.M.; Liu, J.H.; Liu, Q.; Liu, R.G.; Liu, Y.; Liu, Z.A.; Lou, X.C.; Lowery, B.; Lu, J.G.; Ma, A.M.; Ma, E.C.; Ma, J.M.; Mao, H.S.; Mao, Z.P.; Malchow, R.; Mandelkern, M.; Meng, X.C.; Ni, H.L.; Nie, J.; Olsen, S.L.; Oyang, J.; Paluselli, D.; Pan, L.J.; Panetta, J.; Porter, F.; Prabhakar, E.; Qi, N.D.; Que, Y.K.; Quigley, J.; Rong, G.; Schernau, M.; Schmid, B.; Schultz, J.; Shao, Y.Y.; Shen, D.L.; Shen, H.; Shen, X.Y.; Sheng, H.Y.; Shi, H.Z.; Shi, X.R.; Smith, A.; Soderstrom, E.; Song, X.F.; Standifird, J.; Stoker, D.; Sun, F.; Sun, H.S.; Sun, S.J.; Synodinos, J.; Tan, Y.P.; Tang, S.Q.; Toki, W.; Tong, G.L.; Torrence, E.; Wang, F.; Wang, L.S.; Wang, L.Z.; Wang, M.; Wang, P.; Wang, P.L.; Wang, S.M.; Wang, T.J.; Wang, W.; Wang, Y.Y.; Whittaker, S.; Wilson, R.; Wisniewski, W.J.; Xi, D.M.; Xia, X.M.; Xie, P.P.; Xu, D.Z.; Xu, R.S.; Xu, Z.Q.; Xue, S.T.; Yamamoto, R.; Yan, J.; Yan, W.G.; Yang, C.M.; Yang, C.Y.; Yang, W.; Yao, H.B.; Ye, M.H.; Ye, S.Z.; Yu, C.S.; Yu, C.X.; Yu, Z.Q.; Yuan, C.Z.; Zhang, B.Y.; Zhang, C.C.; Zhang, D.H.; Zhang, H.L.; Zhang, J.; Zhang, J.W.; Zhang, L.S.; Zhang, S.Q.; Zhang, Y.; Zhang, Y.Y.; Zhao, D.X.; Zhao, J.W.; Zhao, M.; Zhao, P.D.; Zhao, W.R.; Zhao, W.X.; Zheng, J.H.

    1995-01-01

    The Beijing Spectrometer (BES) Collaboration has observed exclusive pair production of D s mesons at the Beijing Electron-Positron Collider (BEPC) at a center-of-mass energy of 4.03 GeV. The D s mesons are detected in the φπ + , bar K *0 K + , and bar K 0 K + decay modes; two fully reconstructed events yield the value (3.9 -1.9-1.1 +5.1+1.8 )% for the D s branching fraction to φπ. This is the first direct, model-independent measurement of this quantity

  15. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.

    2013-08-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  16. A self-discharge model of Lithium-Sulfur batteries based on direct shuttle current measurement

    DEFF Research Database (Denmark)

    Knap, Vaclav; Stroe, Daniel Loan; Swierczynski, Maciej Jozef

    2016-01-01

    . A simple but comprehensive mathematical model of the Li-S battery cell self-discharge based on the shuttle current was developed and is presented. The shuttle current values for the model parameterization were obtained from the direct shuttle current measurements. Furthermore, the battery cell depth......-of-discharge values were recomputed in order to account for the influence of the self-discharge and provide a higher accuracy of the model. Finally, the derived model was successfully validated against laboratory experiments at various conditions....

  17. Directed flow in heavy-ion collisions at NICA: What is interesting to measure?

    Energy Technology Data Exchange (ETDEWEB)

    Bravina, L.V. [University of Oslo, Department of Physics, Oslo (Norway); National Research Nuclear University ' ' MEPhI' ' , (Moscow Engineering Physics Institute), Moscow (Russian Federation); Goethe University, Frankfurt Institute for Advanced Studies (FIAS), Frankfurt (Germany); Zabrodin, E.E. [University of Oslo, Department of Physics, Oslo (Norway); Lomonosov Moscow State University, Skobeltsyn Institute of Nuclear Physics, Moscow (Russian Federation); National Research Nuclear University ' ' MEPhI' ' , (Moscow Engineering Physics Institute), Moscow (Russian Federation); Goethe University, Frankfurt Institute for Advanced Studies (FIAS), Frankfurt (Germany)

    2016-08-15

    We study the formation of the directed flow of hadrons in nuclear collisions at energies between AGS and SPS in Monte Carlo cascade model. The slope of the proton flow at midrapidity tends to zero (softening) with increasing impact parameter of the collision. For very peripheral topologies this slope becomes negative (antiflow). The effect is caused by rescattering of hadrons in remnants of the colliding nuclei. Since the softening of the proton flow can be misinterpreted as indication of the presence of quark-gluon plasma, we propose several measurements at NICA facility which can help one to distinguish between the cases with and without the plasma formation. (orig.)

  18. An experimental technique for the direct measurement of N2O5 reactivity on ambient particles

    Directory of Open Access Journals (Sweden)

    T. H. Bertram

    2009-06-01

    Full Text Available An experimental approach for the direct measurement of trace gas reactivity on ambient aerosol particles has been developed. The method utilizes a newly designed entrained aerosol flow reactor coupled to a custom-built chemical ionization mass spectrometer. The experimental method is described via application to the measurement of the N2O5 reaction probability, γ (N2O5. Laboratory investigations on well characterized aerosol particles show that measurements of γ (N2O5 observed with this technique are in agreement with previous observations, using conventional flow tube methods, to within ±20% at atmospherically relevant particle surface area concentrations (0–1000 μm2 cm−3. Uncertainty in the measured γ (N2O5 is discussed in the context of fluctuations in potential ambient biases (e.g., temperature, relative humidity and trace gas loadings. Under ambient operating conditions we estimate a single-point uncertainty in γ (N2O5 that ranges between ± (1.3×10-2 + 0.2×γ (N2O5, and ± (1.3×10-3 + 0.2×γ (N2O5 for particle surface area concentrations of 100 to 1000 μm2 cm−3, respectively. Examples from both laboratory investigations and field observations are included alongside discussion of future applications for the reactivity measurement and optimal deployment locations and conditions.

  19. Direct mass measurements of light neutron-rich nuclei using fast recoil spectrometers

    International Nuclear Information System (INIS)

    Vieira, D.J.; Wouters, J.M.

    1987-01-01

    Extensive new mass measurement capabilities have evolved with the development of recoil spectrometers. In the Z = 3 to 9 neutron-rich region alone, 12 neutron-rich nuclei have been determined for the first time by the fast-recoil direct mass measurement method. A recent experiment using the TOFI spectrometer illustrates this technique. A systematic investigation of nuclei that lie along or near the neutron-drip line has provided a valuable first glimpse into the nuclear structure of such nuclei. No evidence for a large single-particle energy gap at N = 14 is observed; however, a change in the two-neutron separation model calculations, and is interpreted in terms of the smaller 1s/sub 1/2/ - 1s/sub 1/2/ interaction compared to that of the 0d/sub 5/2/ - 0d/sub 5/2/ neutron-neutron interaction. 18 refs., 7 figs., 1 tab

  20. Four-point probe measurements of a direct current potential drop on layered conductive cylinders

    International Nuclear Information System (INIS)

    Lu, Yi; Bowler, John R

    2012-01-01

    We have determined the steady state electric field due to direct current flowing via point contacts at the cylindrical surface of a uniformly layered conductive rod of finite length. The solution allows one to use four-point probe potential drop measurements to estimate the conductivity or thickness of the layer assuming that the other parameters are known. The electrical potential in the rod has a zero radial derivative at its surface except at the injection and extractions points. This means that the required solution can be expressed in terms of a Green’s function satisfying a Neumann boundary condition. Four-point measurements have been made to demonstrate the validity of theoretical results. (paper)

  1. Four-point probe measurements of a direct current potential drop on layered conductive cylinders

    Science.gov (United States)

    Lu, Yi; Bowler, John R.

    2012-11-01

    We have determined the steady state electric field due to direct current flowing via point contacts at the cylindrical surface of a uniformly layered conductive rod of finite length. The solution allows one to use four-point probe potential drop measurements to estimate the conductivity or thickness of the layer assuming that the other parameters are known. The electrical potential in the rod has a zero radial derivative at its surface except at the injection and extractions points. This means that the required solution can be expressed in terms of a Green’s function satisfying a Neumann boundary condition. Four-point measurements have been made to demonstrate the validity of theoretical results.

  2. Multiparty Quantum Direct Secret Sharing of Classical Information with Bell States and Bell Measurements

    Science.gov (United States)

    Song, Yun; Li, Yongming; Wang, Wenhua

    2018-02-01

    This paper proposed a new and efficient multiparty quantum direct secret sharing (QDSS) by using swapping quantum entanglement of Bell states. In the proposed scheme, the quantum correlation between the possible measurement results of the members (except dealer) and the original local unitary operation encoded by the dealer was presented. All agents only need to perform Bell measurements to share dealer's secret by recovering dealer's operation without performing any unitary operation. Our scheme has several advantages. The dealer is not required to retain any photons, and can further share a predetermined key instead of a random key to the agents. It has high capacity as two bits of secret messages can be transmitted by an EPR pair and the intrinsic efficiency approaches 100%, because no classical bit needs to be transmitted except those for detection. Without inserting any checking sets for detecting the eavesdropping, the scheme can resist not only the existing attacks, but also the cheating attack from the dishonest agent.

  3. Direct measurements of particle transport in dc glow discharge dusty plasmas

    International Nuclear Information System (INIS)

    Thomas, E. Jr.

    2001-01-01

    Many recent experiments in dc glow discharge plasmas have shown that clouds of dust particles can be suspended near the biased electrodes. Once formed, the dust clouds have well defined boundaries while particle motion within the clouds can be quite complex. Because the dust particles in the cloud can remain suspended in the plasma for tens of minutes, it implies that the particles have a low diffusive loss rate and follow closed trajectories within the cloud. In the experiments discussed in this paper, direct measurements of the dust particle velocities are made using particle image velocimetry (PIV) techniques. From the velocity measurements, a reconstruction of the three-dimensional transport of the dust particles is performed. A qualitative model is developed for the closed motion of the dust particles in a dc glow discharge dusty plasma. (orig.)

  4. A direct approach to fault-tolerance in measurement-based quantum computation via teleportation

    International Nuclear Information System (INIS)

    Silva, Marcus; Danos, Vincent; Kashefi, Elham; Ollivier, Harold

    2007-01-01

    We discuss a simple variant of the one-way quantum computing model (Raussendorf R and Briegel H-J 2001 Phys. Rev. Lett. 86 5188), called the Pauli measurement model, where measurements are restricted to be along the eigenbases of the Pauli X and Y operators, while qubits can be initially prepared both in the vertical bar + π/4 > := 1/√2( vertical bar 0> + e i(π/4) vertical bar 1>) state and the usual vertical bar +> := 1/√2 ( vertical bar 0 > + vertical bar 1>) state. We prove the universality of this quantum computation model, and establish a standardization procedure which permits all entanglement and state preparation to be performed at the beginning of computation. This leads us to develop a direct approach to fault-tolerance by simple transformations of the entanglement graph and preparation operations, while error correction is performed naturally via syndrome-extracting teleportations

  5. Direct measurement of α_Q_E_D(m_Z"2) at the FCC-ee

    International Nuclear Information System (INIS)

    Janot, Patrick

    2016-01-01

    When the measurements from the FCC-ee become available, an improved determination of the standard-model “input' parameters will be needed to fully exploit the new precision data towards either constraining or fitting the parameters of beyond-the-standard-model theories. Among these input parameters is the electromagnetic coupling constant estimated at the Z mass scale, α_Q_E_D(m_Z"2). The measurement of the muon forward-backward asymmetry at the FCC-ee, just below and just above the Z pole, can be used to make a direct determination of α_Q_E_D(m_Z"2) with an accuracy deemed adequate for an optimal use of the FCC-ee precision data.

  6. Direct measurement of alpha_QED(mZ)at the FCC-ee

    CERN Document Server

    Janot, Patrick

    2016-02-08

    When the measurements from the FCC-ee become available, an improved determination of the standard-model "input" parameters will be needed to fully exploit the new precision data towards either constraining or fitting the parameters of beyond-the-standard-model theories. Among these input parameters is the electromagnetic coupling constant estimated at the Z mass scale, alpha_QED(mZ). The measurement of the muon forward- backward asymmetry at the FCC-ee, just below and just above the Z pole, can be used to make a direct determination of alpha_QED(mZ) with an accuracy deemed adequate for an optimal use of the FCC-ee precision data.

  7. Measurement of temperature distributions in large pool fires with the use of directional flame thermometers

    International Nuclear Information System (INIS)

    Koski, Jorman A.

    2000-01-01

    Temperatures inside the flame zone of large regulatory pool fires measured during tests of radioactive materials packages vary widely with both time and position. Measurements made with several Directional Flame Thermometers, in which a thermocouple is attached to a thin metal sheet that quickly approaches flame temperatures, have been used to construct fire temperature distributions and cumulative probability distributions. As an aid to computer simulations of these large fires, these distributions are presented. The distributions are constructed by sorting fire temperature data into bins 10 C wide. A typical fire temperature distribution curve has a gradual increase starting at about 600 C, with the number of observations increasing to a peak near 1000 C, followed by an abrupt decrease in frequency, with no temperatures observed above 1200 C

  8. Environmental Measurement-While-Drilling System and Horizontal Directional Drilling Technology Demonstration, Hanford Site

    International Nuclear Information System (INIS)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A.; Myers, D.A.; Gardner, M.G.; Williamson, T.; Huffman, J.

    1999-01-01

    The Environmental Measurement-While-Drilling (EMWD) system and Horizontal Directional Drilling (HDD) were successfully demonstrated at the Mock Tank Leak Simulation Site and the Drilling Technology Test Site, Hanford, Washington. The use of directional drilling offers an alternative to vertical drilling site characterization. Directional drilling can develop a borehole under a structure, such as a waste tank, from an angled entry and leveling off to horizontal at the desired depth. The EMWD system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drill bit data during drilling operations. The technology demonstration consisted of the development of one borehole under a mock waste tank at a depth of approximately minus8 m (minus27 ft.), following a predetermined drill path, tracking the drill path to within a radius of approximately1.5 m (5 ft.), and monitoring for zones of radiological activity using the EMWD system. The purpose of the second borehole was to demonstrate the capability of drilling to a depth of ∼ -21 m (-70 ft.), the depth needed to obtain access under the Hanford waste tanks, and continue drilling horizontally. This report presents information on the HDD and EMWD technologies, demonstration design, results of the demonstrations, and lessons learned

  9. The half-life of 227Th by direct and indirect measurements

    International Nuclear Information System (INIS)

    Collins, S.M.; Pommé, S.; Jerome, S.M.; Ferreira, K.M.; Regan, P.H.; Pearce, A.K.

    2015-01-01

    Utilising a chemically purified solution the radioactive half-life of 227 Th has been determined indirectly by observation of the ingrowth of 223 Ra using an ionisation chamber (IC) and for the first time by direct observation of the change in activity with time using a high-purity germanium (HPGe) γ-ray spectrometer. The radioactive decay was observed for ~104 days (~5.6 half-lives) by γ-ray spectrometry and approximately 63 days and 72 days (~3.4 and ~3.9 half-lives) using an ionisation chamber (IC). The resulting half-life values – 18.695 (4) days (IC) and 18.683 (20) days (HPGe) – are consistent and detailed uncertainty budgets are presented for the two measurement techniques. A weighted mean of our results of 18.695 (4) days is inconsistent with the most precise published half-life value of 18.7176 (52) days (Jordan and Blanke, 1967). A critical evaluation of literature data has been performed, indicating a paucity of reliable and independent measurements. Selected independent published values have been used to determine a recommended half-life of 18.697 (7) days. A method has been introduced in the course of this work so that the recommended half-life of 227 Th as determined by ingrowth can be modified if a different 223 Ra half-life has been determined, evaluated and adopted. - Highlights: • First direct measurement of 227 Th half-life by HPGe γ-ray spectrometry. • Precision half-life measurement by ionisation chamber. • New half-life of 18.695 (4) days determined. • Critical evaluation of published half-lives and recommended value determined

  10. Direct mass measurements of 100Sn and magic nuclei near the N=Z line

    International Nuclear Information System (INIS)

    Chartier, M.

    1996-01-01

    The masses of nuclei far from stability are of particular interest in nuclear structure studies, and many methods of varying precision have been developed to undertake their measurement. A direct time of flight technique in conjunction with the SPEG spectrometer at GANIL has been extended to the mass measurement of proton-rich nuclei near N = Z line in the mass region A ≅ 60-80 known to provide input for astrophysical modelling of the rp-process and information relevant to the nuclear structure in a region of high deformation. The radioactive beams were produced via the fragmentation of a 78 Kr beam on a nat Ni target, using the new SISSI device. A purification method based on the stripping of the secondary ions was successfully used for the first time, and the masses of 70 Se and 71 Se were measured. In order to improve the mass resolution for heavier nuclei, another method using the second cyclotron of GANIL (CSS2) as a high resolution spectrometer has been developed. An experiment aimed at measuring the masses of A 100 isobars in the vicinity of the doubly magic nucleus 100 Sn was successfully performed, using this original technique. Secondary ions of 100 Ag, 100 Cd, 100 In and 100 Sn produced via fusion-evaporation reaction 50 Cr + 58 Ni and simultaneously accelerated in the CSS2 cyclotron. The mass of 100 Cd and, for the first time, the masses of 100 Sn were determined directly with respect to the reference mass of 100 Ag. These results have been compared to various theoretical predictions and open the discussion on considerations of spin-isospin symmetry. (author)

  11. Direct measurements of methane emissions from abandoned oil and gas wells in Pennsylvania.

    Science.gov (United States)

    Kang, Mary; Kanno, Cynthia M; Reid, Matthew C; Zhang, Xin; Mauzerall, Denise L; Celia, Michael A; Chen, Yuheng; Onstott, Tullis C

    2014-12-23

    Abandoned oil and gas wells provide a potential pathway for subsurface migration and emissions of methane and other fluids to the atmosphere. Little is known about methane fluxes from the millions of abandoned wells that exist in the United States. Here, we report direct measurements of methane fluxes from abandoned oil and gas wells in Pennsylvania, using static flux chambers. A total of 42 and 52 direct measurements were made at wells and at locations near the wells ("controls") in forested, wetland, grassland, and river areas in July, August, October 2013 and January 2014, respectively. The mean methane flow rates at these well locations were 0.27 kg/d/well, and the mean methane flow rate at the control locations was 4.5 × 10(-6) kg/d/location. Three out of the 19 measured wells were high emitters that had methane flow rates that were three orders of magnitude larger than the median flow rate of 1.3 × 10(-3) kg/d/well. Assuming the mean flow rate found here is representative of all abandoned wells in Pennsylvania, we scaled the methane emissions to be 4-7% of estimated total anthropogenic methane emissions in Pennsylvania. The presence of ethane, propane, and n-butane, along with the methane isotopic composition, indicate that the emitted methane is predominantly of thermogenic origin. These measurements show that methane emissions from abandoned oil and gas wells can be significant. The research required to quantify these emissions nationally should be undertaken so they can be accurately described and included in greenhouse gas emissions inventories.

  12. Indirect and direct methods for measuring a dynamic throat diameter in a solid rocket motor

    Science.gov (United States)

    Colbaugh, Lauren

    In a solid rocket motor, nozzle throat erosion is dictated by propellant composition, throat material properties, and operating conditions. Throat erosion has a significant effect on motor performance, so it must be accurately characterized to produce a good motor design. In order to correlate throat erosion rate to other parameters, it is first necessary to know what the throat diameter is throughout a motor burn. Thus, an indirect method and a direct method for determining throat diameter in a solid rocket motor are investigated in this thesis. The indirect method looks at the use of pressure and thrust data to solve for throat diameter as a function of time. The indirect method's proof of concept was shown by the good agreement between the ballistics model and the test data from a static motor firing. The ballistics model was within 10% of all measured and calculated performance parameters (e.g. average pressure, specific impulse, maximum thrust, etc.) for tests with throat erosion and within 6% of all measured and calculated performance parameters for tests without throat erosion. The direct method involves the use of x-rays to directly observe a simulated nozzle throat erode in a dynamic environment; this is achieved with a dynamic calibration standard. An image processing algorithm is developed for extracting the diameter dimensions from the x-ray intensity digital images. Static and dynamic tests were conducted. The measured diameter was compared to the known diameter in the calibration standard. All dynamic test results were within +6% / -7% of the actual diameter. Part of the edge detection method consists of dividing the entire x-ray image by an average pixel value, calculated from a set of pixels in the x-ray image. It was found that the accuracy of the edge detection method depends upon the selection of the average pixel value area and subsequently the average pixel value. An average pixel value sensitivity analysis is presented. Both the indirect

  13. Direct Measurement of Tree Height Provides Different Results on the Assessment of LiDAR Accuracy

    Directory of Open Access Journals (Sweden)

    Emanuele Sibona

    2016-12-01

    Full Text Available In this study, airborne laser scanning-based and traditional field-based survey methods for tree heights estimation are assessed by using one hundred felled trees as a reference dataset. Comparisons between remote sensing and field-based methods were applied to four circular permanent plots located in the western Italian Alps and established within the Alpine Space project NewFor. Remote sensing (Airborne Laser Scanning, ALS, traditional field-based (indirect measurement, IND, and direct measurement of felled trees (DIR methods were compared by using summary statistics, linear regression models, and variation partitioning. Our results show that tree height estimates by Airborne Laser Scanning (ALS approximated to real heights (DIR of felled trees. Considering the species separately, Larix decidua was the species that showed the smaller mean absolute difference (0.95 m between remote sensing (ALS and direct field (DIR data, followed by Picea abies and Pinus sylvestris (1.13 m and 1.04 m, respectively. Our results cannot be generalized to ALS surveys with low pulses density (<5/m2 and with view angles far from zero (nadir. We observed that the tree heights estimation by laser scanner is closer to actual tree heights (DIR than traditional field-based survey, and this was particularly valid for tall trees with conical shape crowns.

  14. Boosting the Direct CP Measurement of the Higgs-Top Coupling.

    Science.gov (United States)

    Buckley, Matthew R; Gonçalves, Dorival

    2016-03-04

    Characterizing the 125 GeV Higgs boson is a critical component of the physics program at the LHC Run II. In this Letter, we consider tt[over ¯]H associated production in the dileptonic mode. We demonstrate that the difference in azimuthal angle between the leptons from top decays can directly reveal the CP structure of the top-Higgs coupling with the sensitivity of the measurement substantially enhanced in the boosted Higgs regime. We first show how to access this channel via H→bb[over ¯] jet-substructure tagging, then demonstrate the ability of the new variable to measure CP. Our analysis includes all signal and background samples simulated via the MC@NLO algorithm including hadronization and underlying-event effects. Using a boosted Higgs substructure with dileptonic tops, we find that the top-Higgs coupling strength and the CP structure can be directly probed with achievable luminosity at the 13 TeV LHC.

  15. Measurement of particle directions in low earth orbit with a Timepix

    International Nuclear Information System (INIS)

    Gohl, St.; Bergmann, B.; Granja, C.; Pichotka, M.; Polansky, S.; Pospisil, S.; Owens, A.

    2016-01-01

    In Low Earth Orbit (LEO) in space electronic equipment aboard satellites and space crews are exposed to high ionizing radiation levels. To reduce radiation damage and the exposure of astronauts, to improve shielding and to assess dose levels, it is valuable to know the composition of the radiation fields and particle directions. The presented measurements are carried out with the Space Application of Timepix Radiation Monitor (SATRAM). There, a Timepix detector (300 μm thick silicon sensor, pixel pitch 55 μm, 256 × 256 pixels) is attached to the Proba-V, an earth observing satellite of the European Space Agency (ESA). The Timepix detector's capability was used to determine the directions of energetic charged particles and their corresponding stopping powers. Data are continuously taken at an altitude of 820 km on a sun-synchronous orbit. The particles pitch angles with respect to the sensor layer were measured and converted to an Earth Centred Earth Fixed (ECEF) coordinate system. Deviations from an isotropic field are extracted by normalization of the observed angular distributions by a Geant4 Monte Carlo simulation —taking the systematics of the reconstruction algorithm and the pixelation into account.

  16. Acquisition and deconvolution of seismic signals by different methods to perform direct ground-force measurements

    Science.gov (United States)

    Poletto, Flavio; Schleifer, Andrea; Zgauc, Franco; Meneghini, Fabio; Petronio, Lorenzo

    2016-12-01

    We present the results of a novel borehole-seismic experiment in which we used different types of onshore-transient-impulsive and non-impulsive-surface sources together with direct ground-force recordings. The ground-force signals were obtained by baseplate load cells located beneath the sources, and by buried soil-stress sensors installed in the very shallow-subsurface together with accelerometers. The aim was to characterize the source's emission by its complex impedance, function of the near-field vibrations and soil stress components, and above all to obtain appropriate deconvolution operators to remove the signature of the sources in the far-field seismic signals. The data analysis shows the differences in the reference measurements utilized to deconvolve the source signature. As downgoing waves, we process the signals of vertical seismic profiles (VSP) recorded in the far-field approximation by an array of permanent geophones cemented at shallow-medium depth outside the casing of an instrumented well. We obtain a significant improvement in the waveform of the radiated seismic-vibrator signals deconvolved by ground force, similar to that of the seismograms generated by the impulsive sources, and demonstrates that the results obtained by different sources present low values in their repeatability norm. The comparison evidences the potentiality of the direct ground-force measurement approach to effectively remove the far-field source signature in VSP onshore data, and to increase the performance of permanent acquisition installations for time-lapse application purposes.

  17. Direct Reflectance Measurements from Drones: Sensor Absolute Radiometric Calibration and System Tests for Forest Reflectance Characterization

    Science.gov (United States)

    Hakala, Teemu; Scott, Barry; Theocharous, Theo; Näsi, Roope; Suomalainen, Juha; Greenwell, Claire; Fox, Nigel

    2018-01-01

    Drone-based remote sensing has evolved rapidly in recent years. Miniaturized hyperspectral imaging sensors are becoming more common as they provide more abundant information of the object compared to traditional cameras. Reflectance is a physically defined object property and therefore often preferred output of the remote sensing data capture to be used in the further processes. Absolute calibration of the sensor provides a possibility for physical modelling of the imaging process and enables efficient procedures for reflectance correction. Our objective is to develop a method for direct reflectance measurements for drone-based remote sensing. It is based on an imaging spectrometer and irradiance spectrometer. This approach is highly attractive for many practical applications as it does not require in situ reflectance panels for converting the sensor radiance to ground reflectance factors. We performed SI-traceable spectral and radiance calibration of a tuneable Fabry-Pérot Interferometer -based (FPI) hyperspectral camera at the National Physical Laboratory NPL (Teddington, UK). The camera represents novel technology by collecting 2D format hyperspectral image cubes using time sequential spectral scanning principle. The radiance accuracy of different channels varied between ±4% when evaluated using independent test data, and linearity of the camera response was on average 0.9994. The spectral response calibration showed side peaks on several channels that were due to the multiple orders of interference of the FPI. The drone-based direct reflectance measurement system showed promising results with imagery collected over Wytham Forest (Oxford, UK). PMID:29751560

  18. Direct measurement of discrete valley and orbital quantum numbers in bilayer graphene.

    Science.gov (United States)

    Hunt, B M; Li, J I A; Zibrov, A A; Wang, L; Taniguchi, T; Watanabe, K; Hone, J; Dean, C R; Zaletel, M; Ashoori, R C; Young, A F

    2017-10-16

    The high magnetic field electronic structure of bilayer graphene is enhanced by the spin, valley isospin, and an accidental orbital degeneracy, leading to a complex phase diagram of broken symmetry states. Here, we present a technique for measuring the layer-resolved charge density, from which we directly determine the valley and orbital polarization within the zero energy Landau level. Layer polarization evolves in discrete steps across 32 electric field-tuned phase transitions between states of different valley, spin, and orbital order, including previously unobserved orbitally polarized states stabilized by skew interlayer hopping. We fit our data to a model that captures both single-particle and interaction-induced anisotropies, providing a complete picture of this correlated electron system. The resulting roadmap to symmetry breaking paves the way for deterministic engineering of fractional quantum Hall states, while our layer-resolved technique is readily extendable to other two-dimensional materials where layer polarization maps to the valley or spin quantum numbers.The phase diagram of bilayer graphene at high magnetic fields has been an outstanding question, with orders possibly between multiple internal quantum degrees of freedom. Here, Hunt et al. report the measurement of the valley and orbital order, allowing them to directly reconstruct the phase diagram.

  19. Direct Reflectance Measurements from Drones: Sensor Absolute Radiometric Calibration and System Tests for Forest Reflectance Characterization.

    Science.gov (United States)

    Hakala, Teemu; Markelin, Lauri; Honkavaara, Eija; Scott, Barry; Theocharous, Theo; Nevalainen, Olli; Näsi, Roope; Suomalainen, Juha; Viljanen, Niko; Greenwell, Claire; Fox, Nigel

    2018-05-03

    Drone-based remote sensing has evolved rapidly in recent years. Miniaturized hyperspectral imaging sensors are becoming more common as they provide more abundant information of the object compared to traditional cameras. Reflectance is a physically defined object property and therefore often preferred output of the remote sensing data capture to be used in the further processes. Absolute calibration of the sensor provides a possibility for physical modelling of the imaging process and enables efficient procedures for reflectance correction. Our objective is to develop a method for direct reflectance measurements for drone-based remote sensing. It is based on an imaging spectrometer and irradiance spectrometer. This approach is highly attractive for many practical applications as it does not require in situ reflectance panels for converting the sensor radiance to ground reflectance factors. We performed SI-traceable spectral and radiance calibration of a tuneable Fabry-Pérot Interferometer -based (FPI) hyperspectral camera at the National Physical Laboratory NPL (Teddington, UK). The camera represents novel technology by collecting 2D format hyperspectral image cubes using time sequential spectral scanning principle. The radiance accuracy of different channels varied between ±4% when evaluated using independent test data, and linearity of the camera response was on average 0.9994. The spectral response calibration showed side peaks on several channels that were due to the multiple orders of interference of the FPI. The drone-based direct reflectance measurement system showed promising results with imagery collected over Wytham Forest (Oxford, UK).

  20. A new method for the direct measurement of the energy absorption coefficient of gamma rays

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.; Shukri, A.; Tajuddin, A.A.; Ghose, A.M.

    1988-01-01

    The most important primary interaction cross section of gamma radiation which is of interest in radiation dosimetry and health physics is the energy absorption coefficient μ en of the medium under study. Direct measurement of μ en is, however, difficult and recourse is t aken to theoretical computations for its estimation. In this study a new, simple and direct method for the determination of μ en is reported. The method is based on paraxial sphere transmission using a proportional-response gamma detector. The bremsstrahlung originating from photoelectrons in the absorbing medium and fluorescence radiations from shielding etc. have been suppressed by using suitable filters. The effects of nonparaxiality of finite sample thickness have been accounted for, using extrapolation procedures. The deviation from nonproportionality and other corrections have been shown to be small. The measured value of μ en for paraffin has been determined as (3.3+-0.2)x10 -3 m 2 /Kg. This compares favourably with the theoretically computed value of 3.35 x 10 -3 m 2 /Kg given by Hubbell et al [pt

  1. Real-time positioning technology in horizontal directional drilling based on magnetic gradient tensor measurement

    Science.gov (United States)

    Deng, Guoqing; Yao, Aiguo

    2017-04-01

    Horizontal directional drilling (HDD) technology has been widely used in Civil Engineering. The dynamic position of the drill bit during construction is one of significant facts determining the accuracy of the trajectory of HDD. A new method now has been proposed to detecting the position of drill bit by measuring the magnetic gradient tensor of the ground solenoid magnetic beacon. Compared with traditional HDD positioning technologies, this new model is much easier to apply with lower request for construction sites and higher positioning efficiency. A direct current (DC) solenoid as a magnetic dipole is placed on ground near the drill bit, and related sensors array which contains four Micro-electromechanical Systems (MEMS ) tri-axial magnetometers, one MEMS tri-axial accelerometer and one MEMS tri-axial gyroscope is set up for measuring the magnetic gradient tensor of the magnetic dipole. The related HDD positioning model has been established and simulation experiments have been carried out to verify the feasibility and reliability of the proposed method. The experiments show that this method has good positioning accuracy in horizontal and vertical direction, and totally avoid the impact of the environmental magnetic field. It can be found that the posture of the magnetic beacon will impact the remote positioning precision within valid positioning range, and the positioning accuracy is higher with longer baseline for limited space in drilling tools. The results prove that the relative error can be limited in 2% by adjusting position of the magnetic beacon, the layers of the enameled coil, the sensitive of magnetometers and the baseline distance. Conclusion can be made that this new method can be applied in HDD positioning with better effect and wider application range than traditional method.

  2. In-situ Measurements of the Direction of Propagation of Pump Waves

    Science.gov (United States)

    James, H. G.; Bernhardt, P. A.; Leyser, T.; Siefring, C. L.

    2017-12-01

    In the course of an experiment to modify the ionosphere, the direction of pump wave propagation is affected by density gradients in the horizontal and vertical directions, fundamentally affecting wave-energy transport. Horizontal gradients on various scales may await a modification attempt as a preexisting state of the ionosphere and/or be changed by the deposition of heater radio-frequency energy. In the results from the Radio Receiver Instrument (RRI) in the enhanced Polar Outflow Probe (e-POP), we have recorded on the order of 100 flights over ionospheric heaters revealing a variety of processes that high-frequency pump waves experience in the ionosphere. E-POP flies on the Canadian satellite CASSIOPE in an elliptic (320 x 1400 km), highly-inclined (81°) orbit. High frequency measurements have been/are being made near SPEAR, HAARP, Sura, EISCAT Heating and Arecibo. Electromagnetic waves from ground-based heaters are detected by the two, orthogonal, 6-m dipoles on the RRI. The high input impedance of the RRI means that the dipoles act as voltage probes, from which the electric field of incoming waves can be simply computed. When combined with cold-magnetoplasma electric-field theory, the relationship of voltages on the two orthogonal dipoles is used to deduce the direction of arrival of an incoming wave in three dimensions. We illustrate the technique by its application to analysis of signals from different transmitters. These results show a variety of pump-wave propagation directions, indicating the complexity of density structure within which modification might take place. Such complexity illustrates the importance of three-dimensional models of density in the vicinity of modification.

  3. Sensor for direct measurement of the boundary shear stress in fluid flow

    Science.gov (United States)

    Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph; Lih, Shyh-Shiuh; Sherrit, Stewart; Chang, Zensheu; Chen, Beck; Widholm, Scott; Ostlund, Patrick

    2011-04-01

    The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear and normal stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear and normal stress and their fluctuations are attractive alternatives. However, this approach is a challenging one especially for high spatial resolution and high fidelity measurements. The authors designed and fabricated a prototype miniature shear stress sensor including an EDM machined floating plate and a high-resolution optical encoder. Tests were performed both in air as well as operation in water with controlled flow. The sensor sensitivity, stability and signal-to-noise level were measured and evaluated. The detailed test results and a discussion of future work will be presented in this paper.

  4. Direct Strain and Slope and Slope Measurement Using 2D DSPSI

    International Nuclear Information System (INIS)

    Dandach, W.; Molimard, J.; Picart, P.

    2011-01-01

    Large variety of optical full-field measurement techniques are being developed and applied to solve mechanical problems. Since each technique possesses its own merits, it is important to know the capabilities and limitations of such techniques. Among these optical full-field methods, interferometry techniques take an important place. They are based on illumination with coherent light (laser). In shearing interferometry the difference of the out of-plane displacement in two neighboring object points is directly measured. Since object displacement does not result in interferometry fringes, the method is suited for localization of strain concentrations and is indeed used in industry for this purpose. DSPSI possesses the advantage over conventional out-of-plane displacement-sensitive interferometry, that only a single difference of the unwrapped phase map is required to obtain flexural strains, thereby relieving problems with noise and reduction in the field of view. A first work in this domain (DSPSI) [1] was made in 1973, later recent studies emerged to provide a quantitative system of measurements [2]. This work aims to present the results of strain and slope measurements using digital speckle pattern shearing interferometry (DSPSI). (author)

  5. Qweak: First Direct Measurement of the Weak Charge of the Proton

    Directory of Open Access Journals (Sweden)

    Nuruzzaman

    2014-04-01

    Full Text Available The Qweak experiment at Hall C of Thomas Jefferson National Accelerator Facility has made the first direct measurement of the weak charge of the proton, QWp, through a precision measurement of the parity-violating asymmetry in elastic e-p scattering at low momentum transfer Q2= 0.025 (GeV/c2 with incident electron beam energy of 1.155 GeV. The Qweak experiment, along with earlier results of parity violating elastic scattering experiments, is expected to determine the most precise value of QWp which is suppressed in the Standard Model. If this result is further combined with the 133Cs atomic parity violation (APV measurement, significant constraints on the weak charge of the up quark, down quark, and neutron can be extracted. This data will also be used to determine the weak-mixing angle, sin2 θW, with a relative uncertainty of < 0.5% that will provide a competitive measurement of the running of sin2 θW to low Q2. An overview of the experiment and its results using the commissioning dataset, constituting approximately 4% of the data collected in the experiment, are reported here.

  6. Galactically inertial space probes for the direct measurement of the metric expansion of the universe

    International Nuclear Information System (INIS)

    Cagnani, Ivan

    2011-01-01

    Astrometric data from the future GAIA and OBSS missions will allow a more precise calculation of the local galactic circular speed, and better measurements of galactic movements relative to the CMB will be obtained by post-WMAP missions (ie Planck). Contemporary development of high specific impulse electric propulsion systems (ie VASIMIR) will enable the development of space probes able to properly compensate the galactic circular speed as well as the resulting attraction to the centre of our galaxy. The probes would appear immobile to an ideal observer fixed at the centre of the galaxy, in contrast of every other galactic object, which would appear moving according to their local galactic circular speed and their proper motions. Arranging at least three of these galactically static probes in an extended formation and measuring reciprocal distances of the probes over time with large angle laser ranges could allow a direct measurement of the metric expansion of the universe. Free-drifting laser-ranged targets released by the spacecrafts could also be used to measure and compensate solar system's induced local perturbations. For further reducing local effects and increase the accuracy of the results, the distance between the probes should be maximized and the location of the probes should be as far as possible from the Sun and any massive object (ie Jupiter, Saturn). Gravitational waves could also induce random errors but data from GW observatories like the planned LISA could be used to correct them.

  7. Comparison of fine particle measurements from a direct-reading instrument and a gravimetric sampling method.

    Science.gov (United States)

    Kim, Jee Young; Magari, Shannon R; Herrick, Robert F; Smith, Thomas J; Christiani, David C

    2004-11-01

    Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed In this study, two such measurement methods were used simultaneously and compared. PM2.5 was sampled using a filter-based gravimetric sampling method and a direct-reading instrument, the TSI Inc. model 8520 DUSTTRAK aerosol monitor. Both sampling methods were used to determine the PM2.5 exposure in a group of boilermakers exposed to welding fumes and residual fuel oil ash. The geometric mean PM2.5 concentration was 0.30 mg/m3 (GSD 3.25) and 0.31 mg/m3 (GSD 2.90)from the DUSTTRAK and gravimetric method, respectively. The Spearman rank correlation coefficient for the gravimetric and DUSTTRAK PM2.5 concentrations was 0.68. Linear regression models indicated that log, DUSTTRAK PM2.5 concentrations significantly predicted loge gravimetric PM2.5 concentrations (p gravimetric PM2.5 concentrations was found to be modified by surrogate measures for seasonal variation and type of aerosol. PM2.5 measurements from the DUSTTRAK are well correlated and highly predictive of measurements from the gravimetric sampling method for the aerosols in these work environments. However, results from this study suggest that aerosol particle characteristics may affect the relationship between the gravimetric and DUSTTRAK PM2.5 measurements. Recalibration of the DUSTTRAK for the specific aerosol, as recommended by the manufacturer, may be necessary to produce valid measures of airborne particulate matter.

  8. Direct measurement of electron beam quality conversion factors using water calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, James, E-mail: james.renaud@mail.mcgill.ca; Seuntjens, Jan [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4 (Canada); Sarfehnia, Arman [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 3E2 (Canada); Marchant, Kristin [Allan Blair Cancer Centre, Saskatchewan Cancer Agency, Regina, Saskatchewan S4T 7T1, Canada and Department of Oncology, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A1 (Canada); McEwen, Malcolm; Ross, Carl [Ionizing Radiation Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6 (Canada)

    2015-11-15

    Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol

  9. Direct measurement of electron beam quality conversion factors using water calorimetry.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Marchant, Kristin; McEwen, Malcolm; Ross, Carl; Seuntjens, Jan

    2015-11-01

    In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9-20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%-0.40%) and its influence on the perturbation correction (Type B, 0.10%-0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, kecal, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM's TG-51 protocol. General agreement between the relative

  10. Direct measurements of meltwater runoff on the Greenland ice sheet surface.

    Science.gov (United States)

    Smith, Laurence C; Yang, Kang; Pitcher, Lincoln H; Overstreet, Brandon T; Chu, Vena W; Rennermalm, Åsa K; Ryan, Jonathan C; Cooper, Matthew G; Gleason, Colin J; Tedesco, Marco; Jeyaratnam, Jeyavinoth; van As, Dirk; van den Broeke, Michiel R; van de Berg, Willem Jan; Noël, Brice; Langen, Peter L; Cullather, Richard I; Zhao, Bin; Willis, Michael J; Hubbard, Alun; Box, Jason E; Jenner, Brittany A; Behar, Alberto E

    2017-12-12

    Meltwater runoff from the Greenland ice sheet surface influences surface mass balance (SMB), ice dynamics, and global sea level rise, but is estimated with climate models and thus difficult to validate. We present a way to measure ice surface runoff directly, from hourly in situ supraglacial river discharge measurements and simultaneous high-resolution satellite/drone remote sensing of upstream fluvial catchment area. A first 72-h trial for a 63.1-km 2 moulin-terminating internally drained catchment (IDC) on Greenland's midelevation (1,207-1,381 m above sea level) ablation zone is compared with melt and runoff simulations from HIRHAM5, MAR3.6, RACMO2.3, MERRA-2, and SEB climate/SMB models. Current models cannot reproduce peak discharges or timing of runoff entering moulins but are improved using synthetic unit hydrograph (SUH) theory. Retroactive SUH applications to two older field studies reproduce their findings, signifying that remotely sensed IDC area, shape, and supraglacial river length are useful for predicting delays in peak runoff delivery to moulins. Applying SUH to HIRHAM5, MAR3.6, and RACMO2.3 gridded melt products for 799 surrounding IDCs suggests their terminal moulins receive lower peak discharges, less diurnal variability, and asynchronous runoff timing relative to climate/SMB model output alone. Conversely, large IDCs produce high moulin discharges, even at high elevations where melt rates are low. During this particular field experiment, models overestimated runoff by +21 to +58%, linked to overestimated surface ablation and possible meltwater retention in bare, porous, low-density ice. Direct measurements of ice surface runoff will improve climate/SMB models, and incorporating remotely sensed IDCs will aid coupling of SMB with ice dynamics and subglacial systems. Copyright © 2017 the Author(s). Published by PNAS.

  11. Direct Measurement of Neutral/Ion Beam Power using Thermocouple Analysis

    International Nuclear Information System (INIS)

    Day, I.; Gee, S.

    2006-01-01

    Modern Neutral Beam Injection systems such as those used on JET and MAST routinely use thermocouples embedded close to the surface of beam stopping elements, such as calorimeters and ion dumps, coupled to high speed data acquisition systems to determine beam profile and position from temperature rise data. With the availability of low cost data acquisition and storage systems it is now possible to record data from all thermocouples in a fully instrumented calorimeter or ion dump on 20 ms timescales or better. This sample rate is sufficiently fast to enable the thermocouple data to be used to calculate the incident power density from 1d heat transfer theory. This power density data coupled with appropriate Gaussian fits enables the determination of the 2d beam profile and thus allows an instantaneous and direct measurement of beam power. The theory and methodology required to analyse the fast thermocouple data from the MAST calorimeter and residual ion dump thermocouples is presented and direct measurements of beam power density are demonstrated. The power of desktop computers allows such analysis to be carried out virtually instantaneously. The methods used to automate this analysis are discussed in detail. A code, utilising the theory and methodology, has been developed to allow immediate measurements of beam power on a pulse by pulse basis. The uncertainty in determining the beam power density is shown to be less than 10 %. This power density data is then fitted to a 2d Gaussian beam profile and integrated to establish the total beam power. Results of this automated analysis for the neutral beam and residual ion power of the MAST duopigatron and PINI NBI systems are presented. This technology could be applied to a beam power safety interlock system. The application to a beam shine through protection system for the inner wall of the JET Tokamak is discussed as an example. (author)

  12. Intrinsic reaction kinetics of coal char combustion by direct measurement of ignition temperature

    International Nuclear Information System (INIS)

    Kim, Ryang-Gyoon; Jeon, Chung-Hwan

    2014-01-01

    A wire heating reactor that can use a synchronized experimental method was developed to obtain the intrinsic kinetics of large coal char particles ranging in size from 0.4 to 1 mm. This synchronization system consists of three parts: a thermocouple wire for both heating and direct measurement of the particle temperature, a photodetector sensor for determining ignition/burnout points by measuring the intensity of luminous emission from burning particles, and a high-speed camera–long-distance microscope for observing and recording the movement of luminous zone directly. Coal char ignition was found to begin at a spot on the particle's external surface and then moved across the entire particle. Moreover, the ignition point determined according to the minimum of dT/dt is a spot point and not a full growth point. The ignition temperature of the spot point rises as the particle diameter increases. A spot ignition model, which describes the ignition in terms of the internal conduction and external/internal oxygen diffusion, was then developed to evaluate the intrinsic kinetics and predict the ignition temperature of the coal char. Internal conduction was found to be important in large coal char particles because its effect becomes greater than that of oxygen diffusion as the particle diameter increases. In addition, the intrinsic kinetics of coal char obtained from the spot ignition model for two types of coal does not differ significantly from the results of previous investigators. -- Highlights: • A novel technique was used to measure the coal char particle temperature. • The ignition point determined from a dT/dt minimum is a spot ignition point. • A spot ignition model was suggested to analyze the intrinsic reaction kinetics of coal char. • Internal conduction has to be considered in order to evaluate the intrinsic kinetics for larger particle (above 1 mm)

  13. Direct measurements of meltwater runoff on the Greenland ice sheet surface

    Science.gov (United States)

    Smith, Laurence C.; Yang, Kang; Pitcher, Lincoln H.; Overstreet, Brandon T.; Chu, Vena W.; Rennermalm, Åsa K.; Ryan, Jonathan C.; Cooper, Matthew G.; Gleason, Colin J.; Tedesco, Marco; Jeyaratnam, Jeyavinoth; van As, Dirk; van den Broeke, Michiel R.; van de Berg, Willem Jan; Noël, Brice; Langen, Peter L.; Cullather, Richard I.; Zhao, Bin; Willis, Michael J.; Hubbard, Alun; Box, Jason E.; Jenner, Brittany A.; Behar, Alberto E.

    2017-12-01

    Meltwater runoff from the Greenland ice sheet surface influences surface mass balance (SMB), ice dynamics, and global sea level rise, but is estimated with climate models and thus difficult to validate. We present a way to measure ice surface runoff directly, from hourly in situ supraglacial river discharge measurements and simultaneous high-resolution satellite/drone remote sensing of upstream fluvial catchment area. A first 72-h trial for a 63.1-km2 moulin-terminating internally drained catchment (IDC) on Greenland's midelevation (1,207–1,381 m above sea level) ablation zone is compared with melt and runoff simulations from HIRHAM5, MAR3.6, RACMO2.3, MERRA-2, and SEB climate/SMB models. Current models cannot reproduce peak discharges or timing of runoff entering moulins but are improved using synthetic unit hydrograph (SUH) theory. Retroactive SUH applications to two older field studies reproduce their findings, signifying that remotely sensed IDC area, shape, and supraglacial river length are useful for predicting delays in peak runoff delivery to moulins. Applying SUH to HIRHAM5, MAR3.6, and RACMO2.3 gridded melt products for 799 surrounding IDCs suggests their terminal moulins receive lower peak discharges, less diurnal variability, and asynchronous runoff timing relative to climate/SMB model output alone. Conversely, large IDCs produce high moulin discharges, even at high elevations where melt rates are low. During this particular field experiment, models overestimated runoff by +21 to +58%, linked to overestimated surface ablation and possible meltwater retention in bare, porous, low-density ice. Direct measurements of ice surface runoff will improve climate/SMB models, and incorporating remotely sensed IDCs will aid coupling of SMB with ice dynamics and subglacial systems.

  14. Direct and indirect measurement of neuromuscular fatigue in Canadian football players.

    Science.gov (United States)

    Clarke, Nick; Farthing, Jonathan P; Lanovaz, Joel L; Krentz, Joel R

    2015-05-01

    This study assessed the effects of a fatiguing game simulation (G-Sim) on the balance of collegiate Canadian football players. The purpose of the study was to evaluate postural control as a potential tool for monitoring neuromuscular fatigue (NMF) in collision-based team sports. Fifteen male Canadian football players were recruited (mean±SD: age 21.8±1.6 years, weight 97.6±14.7 kg). Indirect NMF measures (postural sway and countermovement jump (CMJ)) were performed 24 h before (TBase), immediately before (TPre) and after (TPost), and 24 h (T24) and 48 h after (T48) a Canadian football G-Sim. Peak isometric knee extensor torque of a maximal voluntary contraction (MVC) and electrically evoked tetani at 20 Hz (P20) and 80 Hz (P80) were also recorded as direct NMF measures at TBase, TPre, TPost, and T48. At TPost, we observed significant declines in MVC, P20, and the MVC/P80 ratio (-15.3%, -15.7%, and -12.1%, respectively; n=12) along with reductions in CMJ takeoff velocity and peak power (-6.9% and -6.5%, respectively; n=12) and larger area of the center of pressure trajectory (95.2%; n=10) during a 60-s postural sway task. All variables were no longer different than baseline by T48. Acute neuromuscular impairment in this cohort is likely attributable to alterations in excitation-contraction coupling due to structural damage and central activation failure. Congruency between the direct and indirect measures of NMF suggests monitoring postural sway has the potential to identify both neuromuscular and somatosensory alterations induced by acute game-induced fatigue in collision-based team sports players.

  15. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  16. Advances in the simulation and automated measurement of well-sorted granular material: 2. Direct measures of particle properties

    Science.gov (United States)

    Buscombe, D.; Rubin, D. M.

    2012-06-01

    In this, the second of a pair of papers on the structure of well-sorted natural granular material (sediment), new methods are described for automated measurements from images of sediment, of: 1) particle-size standard deviation (arithmetic sorting) with and without apparent void fraction; and 2) mean particle size in material with void fraction. A variety of simulations of granular material are used for testing purposes, in addition to images of natural sediment. Simulations are also used to establish that the effects on automated particle sizing of grains visible through the interstices of the grains at the very surface of a granular material continue to a depth of approximately 4 grain diameters and that this is independent of mean particle size. Ensemble root-mean squared error between observed and estimated arithmetic sorting coefficients for 262 images of natural silts, sands and gravels (drawn from 8 populations) is 31%, which reduces to 27% if adjusted for bias (slope correction between observed and estimated values). These methods allow non-intrusive and fully automated measurements of surfaces of unconsolidated granular material. With no tunable parameters or empirically derived coefficients, they should be broadly universal in appropriate applications. However, empirical corrections may need to be applied for the most accurate results. Finally, analytical formulas are derived for the one-step pore-particle transition probability matrix, estimated from the image's autocorrelogram, from which void fraction of a section of granular material can be estimated directly. This model gives excellent predictions of bulk void fraction yet imperfect predictions of pore-particle transitions.

  17. Direct measurement of first-pass ileal clearance of a bile acid in humans

    International Nuclear Information System (INIS)

    Galatola, G.; Jazrawi, R.P.; Bridges, C.; Joseph, A.E.; Northfield, T.C.

    1991-01-01

    The purpose of this study was to develop and validate a method of directly measuring ileal bile acid absorption efficiency during a single enterohepatic cycle (first-pass ileal clearance). This has become feasible for the first time because of the availability of the synthetic gamma-labeled bile acid 75Selena-homocholic acid-taurine (75SeHCAT). Together with the corresponding natural bile acid cholic acid-taurine (labeled with 14C), SeHCAT was infused distal to an occluding balloon situated beyond the ampulla of Vater in six healthy subjects. Completion of a single enterohepatic cycle was assessed by obtaining a plateau for 75SeHCAT activity proximal to the occluding balloon, which prevented further cycles. Unabsorbed 75SeHCAT was collected after total gut washout, which was administered distal to the occluding balloon. 75SeHCAT activity in the rectal effluent measured by gamma counter was compared with that of absorbed 75SeHCAT level measured by gamma camera and was used to calculate first-pass ileal clearance. This was very efficient (mean value, 96%) and showed very little variation in the six subjects studied (range, 95%-97%). A parallel time-activity course in hepatic bile for 14C and 75Se during a single enterohepatic cycle, together with a ratio of unity for 14C/75Se in samples obtained at different time intervals, suggests that 75SeHCAT is handled by the ileum like the natural bile acid cholic acid-taurine. Extrapolation of 75SeHCAT first-pass ileal clearance to that of the natural bile acid therefore seems justifiable. In a subsidiary experiment, ileal absorption efficiency per day for 75SeHCAT was also measured by scanning the gallbladder area on 5 successive days after the measurement of first-pass ileal clearance. In contrast with absorption efficiency per cycle, absorption efficiency per day varied widely (49%-86%)

  18. Reducing heliostat field costs by direct measurement and control of the mirror orientation

    Science.gov (United States)

    van den Donker, P.; Rosinga, G.; van Voorthuysen, E. du Marchie

    2016-05-01

    The first commercial CSP Central Receiver System has been in operation since 2007. The technology required for such a central receiver system is quite new. The determining factor of the price of electricity is the capital investment in the heliostat field. The cost level per square meter of the heliostat field is rather high. Sun2point is questioning the market development, which is trying to get the cost level down by aiming at large heliostats. Sun2Point aims at mass manufacturing small heliostats to achieve low prices. Mass manufacturing off-site and transport over long distances is possible for small heliostats only. Calibration on the spot is a labour-intensive activity. Autonomous, factory calibrated and wireless controlled heliostats are the solution to lower installation cost. A new measurement method that directly reports the orientation of the heliostat in relation to the earth and the sun can solve the calibration problem when the heliostats are installed. The application of small heliostats will be much cheaper as a result of this measurement method. In this paper several methods for such a measurement are described briefly. The new Sun2Point method has successfully been tested. In this paper Sun2Point challenges the CSP community to investigate this approach. A brief survey is presented of many aspects that lead to a low price.

  19. Direct concentration and viability measurement of yeast in corn mash using a novel imaging cytometry method.

    Science.gov (United States)

    Chan, Leo L; Lyettefi, Emily J; Pirani, Alnoor; Smith, Tim; Qiu, Jean; Lin, Bo

    2011-08-01

    Worldwide awareness of fossil-fuel depletion and global warming has been increasing over the last 30 years. Numerous countries, including the USA and Brazil, have introduced large-scale industrial fermentation facilities for bioethanol, biobutanol, or biodiesel production. Most of these biofuel facilities perform fermentation using standard baker's yeasts that ferment sugar present in corn mash, sugar cane, or other glucose media. In research and development in the biofuel industry, selection of yeast strains (for higher ethanol tolerance) and fermentation conditions (yeast concentration, temperature, pH, nutrients, etc.) can be studied to optimize fermentation performance. Yeast viability measurement is needed to identify higher ethanol-tolerant yeast strains, which may prolong the fermentation cycle and increase biofuel output. In addition, yeast concentration may be optimized to improve fermentation performance. Therefore, it is important to develop a simple method for concentration and viability measurement of fermenting yeast. In this work, we demonstrate an imaging cytometry method for concentration and viability measurements of yeast in corn mash directly from operating fermenters. It employs an automated cell counter, a dilution buffer, and staining solution from Nexcelom Bioscience to perform enumeration. The proposed method enables specific fluorescence detection of viable and nonviable yeasts, which can generate precise results for concentration and viability of yeast in corn mash. This method can provide an essential tool for research and development in the biofuel industry and may be incorporated into manufacturing to monitor yeast concentration and viability efficiently during the fermentation process.

  20. Measurements of direct CP-violating asymmetries in charmless decays of bottom baryons.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2014-12-12

    We report final measurements of direct CP-violating asymmetries in charmless decays of neutral bottom hadrons to pairs of charged hadrons with the upgraded Collider Detector at the Fermilab Tevatron. Using the complete √s=1.96  TeV proton-antiproton collisions data set, corresponding to 9.3  fb⁻¹ of integrated luminosity, we measure A(Λ(b)⁰→pπ⁻)=+0.06±0.07(stat)±0.03(syst) and A(Λ(b)⁰→pK⁻)=-0.10±0.08(stat)±0.04(syst), compatible with no asymmetry. In addition we measure the CP-violating asymmetries in B(s)⁰→K⁻π⁺ and B⁰→K⁺π⁻ decays to be A(B(s)⁰→K⁻π⁺)=+0.22±0.07(stat)±0.02(syst) and A(B⁰→K⁺π⁻)=-0.083±0.013(stat)±0.004(syst), respectively, which are significantly different from zero and consistent with current world averages.

  1. Anodal transcranial direct current stimulation reduces psychophysically measured surround suppression in the human visual cortex.

    Directory of Open Access Journals (Sweden)

    Daniel P Spiegel

    Full Text Available Transcranial direct current stimulation (tDCS is a safe, non-invasive technique for transiently modulating the balance of excitation and inhibition within the human brain. It has been reported that anodal tDCS can reduce both GABA mediated inhibition and GABA concentration within the human motor cortex. As GABA mediated inhibition is thought to be a key modulator of plasticity within the adult brain, these findings have broad implications for the future use of tDCS. It is important, therefore, to establish whether tDCS can exert similar effects within non-motor brain areas. The aim of this study was to assess whether anodal tDCS could reduce inhibitory interactions within the human visual cortex. Psychophysical measures of surround suppression were used as an index of inhibition within V1. Overlay suppression, which is thought to originate within the lateral geniculate nucleus (LGN, was also measured as a control. Anodal stimulation of the occipital poles significantly reduced psychophysical surround suppression, but had no effect on overlay suppression. This effect was specific to anodal stimulation as cathodal stimulation had no effect on either measure. These psychophysical results provide the first evidence for tDCS-induced reductions of intracortical inhibition within the human visual cortex.

  2. Modeling of Production and Quality of Bioethanol Obtained from Sugarcane Fermentation Using Direct Dissolved Sugars Measurements

    Directory of Open Access Journals (Sweden)

    Borja Velazquez-Marti

    2016-04-01

    Full Text Available Bioethanol production from sugarcane represents an opportunity for urban-agricultural development in small communities of Ecuador. Despite the fact that the industry for bioethanol production from sugarcane in Brazil is fully developed, it is still considered expensive as a small rural business. In order to be able to reduce the costs of monitoring the production process, and avoid the application of expensive sensors, the aim of this research was modeling the kinetics of production of bioethanol based on direct measurements of Brix grades, instead of the concentration of alcohol, during the process of cane juice bio-fermentation with Saccharomyces cerevisiae. This avoids the application of expensive sensors that increase the investment costs. Fermentation experiments with three concentrations of yeast and two temperatures were carried out in a laboratory reactor. In each case Brix grades, amount of ethanol and alcoholic degree were measured. A mathematical model to predict the quality and production of bioethanol was developed from Brix grade measurements, obtaining an adjusted coefficient of determination of 0.97. The model was validated in a pilot plant.

  3. Direct measurement of methane hydrate composition along the hydrate equilibrium boundary

    Science.gov (United States)

    Circone, S.; Kirby, S.H.; Stern, L.A.

    2005-01-01

    The composition of methane hydrate, namely nW for CH 4??nWH2O, was directly measured along the hydrate equilibrium boundary under conditions of excess methane gas. Pressure and temperature conditions ranged from 1.9 to 9.7 MPa and 263 to 285 K. Within experimental error, there is no change in hydrate composition with increasing pressure along the equilibrium boundary, but nW may show a slight systematic decrease away from this boundary. A hydrate stoichiometry of n W = 5.81-6.10 H2O describes the entire range of measured values, with an average composition of CH4??5.99(??0.07) H2O along the equilibrium boundary. These results, consistent with previously measured values, are discussed with respect to the widely ranging values obtained by thermodynamic analysis. The relatively constant composition of methane hydrate over the geologically relevant pressure and temperature range investigated suggests that in situ methane hydrate compositions may be estimated with some confidence. ?? 2005 American Chemical Society.

  4. The Need for Direct High-Energy Cosmic-Ray Measurements

    Science.gov (United States)

    Jones, Frank C.; Streitmatter, Robert

    2004-01-01

    Measuring the chemical composition of the cosmic rays in the energy region of greater than or equal to 10(exp 12)eV would be highly useful in settling several nagging questions concerning the propagation of cosmic rays in the galaxy. In particular an accurate measurement of secondary to primary ratios such as Boron to Carbon would gibe clear evidence as to whether the propagation of cosmic rays is determined by a diffusion coefficient that varies with the particle's energy as E(sup 0.5) or E(sup 0.3). This would go a long ways in helping us to understand the anistropy (or lack thereof) of the highest energy cosmic rays and the power requirements for producing those particles at approximately equal to 10(exp 18) eV which are believed to be highest energy particles produced in the Galaxy. This would be only one of the benefits of a mission such as ACCESS to perform direct particle measurements on very high energy cosmic rays.

  5. Measurements of Direct CP Violation, CPT Symmetry, and Other Parameters in the Neutral Kaon System

    Energy Technology Data Exchange (ETDEWEB)

    Worcester, Elizabeth Turner [Univ. of Chicago, IL (United States)

    2007-12-01

    The authors present precision measurements of the direct CP violation parameter, Re(ϵ'/ϵ), the kaon parameters, Δm and τS, and the CPT tests, Φ± and ΔΦ, in neutral kaon decays. These results are based on the full dataset collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This dataset contains ~ 15 million K → π0π0 decays and ~ 69 million K → π+π- decays. They describe significant improvements to the precision of these measurements relative to previous KTeV analyses. They find Re(ϵ'/ϵ = [19.2 ± 1.1(stat) ± 1.8(syst)] x 10-4, Δm = (5265 ± 10) x 106 hs-1, and τS = (89.62 ± 0.05) x 10-12 s. They measure Φ± = (44.09 ± 1.00)° and ΔΦ = (0.29 ± 0.31)°; these results are consistent with CPT symmetry.

  6. Direct measurements show decreasing methane emissions from natural gas local distribution systems in the United States.

    Science.gov (United States)

    Lamb, Brian K; Edburg, Steven L; Ferrara, Thomas W; Howard, Touché; Harrison, Matthew R; Kolb, Charles E; Townsend-Small, Amy; Dyck, Wesley; Possolo, Antonio; Whetstone, James R

    2015-04-21

    Fugitive losses from natural gas distribution systems are a significant source of anthropogenic methane. Here, we report on a national sampling program to measure methane emissions from 13 urban distribution systems across the U.S. Emission factors were derived from direct measurements at 230 underground pipeline leaks and 229 metering and regulating facilities using stratified random sampling. When these new emission factors are combined with estimates for customer meters, maintenance, and upsets, and current pipeline miles and numbers of facilities, the total estimate is 393 Gg/yr with a 95% upper confidence limit of 854 Gg/yr (0.10% to 0.22% of the methane delivered nationwide). This fraction includes emissions from city gates to the customer meter, but does not include other urban sources or those downstream of customer meters. The upper confidence limit accounts for the skewed distribution of measurements, where a few large emitters accounted for most of the emissions. This emission estimate is 36% to 70% less than the 2011 EPA inventory, (based largely on 1990s emission data), and reflects significant upgrades at metering and regulating stations, improvements in leak detection and maintenance activities, as well as potential effects from differences in methodologies between the two studies.

  7. Methane Emission By Grazing Livestock. A Synopsis Of 1000 Direct Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lassey, K.R. [National Institute of Water and Atmospheric Research (NIWA), Wellington (New Zealand); Ulyatt, M.J. [New Zealand Pastoral Agriculture Research Institute (AgResearch), Palmerston North (New Zealand)

    2000-07-01

    In a series of field campaigns since 1995, a team of atmospheric and ruminant-nutrition scientists have measured methane emissions directly from individual ruminant livestock freely grazing representative New Zealand pastures. The technique collects integrated 'breath' samples during grazing, using an implanted SF6 source as a conservative calibrated tracer, an approach pioneered by Johnson et al. [1994]. Most of these measurements have been on grazing sheep (942 animal-days to Aug 1999), others on grazing dairy cows (283), with some measurements also on sheep under controlled feeding conditions (305) [eg, Lassey et al., 1997; Ulyatt et al., 1999]. The aim is to characterise the variability of emission rates, including their dependence on pasture quality and physiological condition. The research goal is two-fold: (1) to provide a better scientific basis for assessing the national emissions inventory; and (2) to investigate options for mitigating livestock emissions. Here, we discuss the research strategy and overview the principal research findings. We note in particular, that as a source of enterically fermented methane, sheep may not be merely 'small cattle'. 5 refs.

  8. Application possibility of the direct current conduction method for nondestructive crack measurement

    International Nuclear Information System (INIS)

    Riedl, R.

    1982-01-01

    An important value to determine the danger of cracks is the determination of crack depths. The crack depth can be determined quite accurate by means of the direct current conduction method, if one holds onto certain rules. Often complicated experimental set-ups are applied. However, portable commercial devices can be obtained that can be used for partial fluxation, that yield good results. By means of two examples: crack conduction samples in which the built-up of a constant-cracking is persued up to a certain depth, as well as the persuasion of an continuing crack in a bearing cylinder, shall be demonstrated that is very well possible to record accurate profiles with commercial devices and to avoid expensive measurement devices. (orig.) [de

  9. Direct measurement and characterization of active photosynthesis zones inside biofuel producing and wastewater remediating microalgal biofilms

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Hans C.; Kesaano, Maureen; Moll, Karen; Smith, Terence; Gerlach, Robin; Carlson, Ross; Miller, Charles D.; Peyton, Brent; Cooksey, Keith; Gardner, Robert D.; Sims, Ronald C.

    2014-03-01

    Abstract: Microalgal biofilm based technologies are of keen interest due to their high biomass concentrations and ability to utilize renewable resources, such as light and CO2. While photoautotrophic biofilms have long been used for wastewater remediation applications, biofuel production represents a relatively new and under-represented focus area. However, the direct measurement and characterization of fundamental parameters required for physiological analyses are challenging due to biofilm heterogeneity. This study evaluated oxygenic photosynthesis and biofuel precursor molecule production using a novel rotating algal biofilm reactor (RABR) operated at field- and laboratory-scales for wastewater remediation and biofuel production, respectively. Clear differences in oxygenic-photosynthesis, respiration and biofuel-precursor capacities were observed between the two systems and different conditions based on light and nitrogen availability. Nitrogen depletion was not found to have the same effect on lipid accumulation compared to prior planktonic studies. Physiological characterizations of these microalgal biofilms identify potential areas for future process optimization.

  10. Measurement of direct CP-violation with the NA48 experiment at the CERN SPS

    CERN Document Server

    Blümer, H

    1999-01-01

    The NA48 experiment at the CERN SPS uses simultaneous, nearly collinear beams of long-lived and short-lived neutral kaons to measure the direct CP-violation parameter epsilon '/ epsilon using the double ratio method to an overall accuracy of 2.10/sup -4/, three times better than previous results. The detector has been installed and commissioned in 1995 and 1996. First physics data were recorded during 42 days in fall 1997 yielding more events than the previous experiment NA31. The talk presents the apparatus performance, data quality, the current status of the physics analysis and ongoing activities. The experiment has performed another data run from May to September 1998, which has given a substantial increase in statistics. (11 refs).

  11. Direct measurement of the biphoton Wigner function through two-photon interference

    Science.gov (United States)

    Douce, T.; Eckstein, A.; Walborn, S. P.; Khoury, A. Z.; Ducci, S.; Keller, A.; Coudreau, T.; Milman, P.

    2013-01-01

    The Hong-Ou-Mandel (HOM) experiment was a benchmark in quantum optics, evidencing the non–classical nature of photon pairs, later generalized to quantum systems with either bosonic or fermionic statistics. We show that a simple modification in the well-known and widely used HOM experiment provides the direct measurement of the Wigner function. We apply our results to one of the most reliable quantum systems, consisting of biphotons generated by parametric down conversion. A consequence of our results is that a negative value of the Wigner function is a sufficient condition for non-gaussian entanglement between two photons. In the general case, the Wigner function provides all the required information to infer entanglement using well known necessary and sufficient criteria. The present work offers a new vision of the HOM experiment that further develops its possibilities to realize fundamental tests of quantum mechanics using simple optical set-ups. PMID:24346262

  12. Direct mass measurements of neutron-deficient xenon isotopes using the ISOLTRAP mass spectrometer

    CERN Document Server

    Dilling, J; Beck, D; Bollen, G; Herfurth, F; Kellerbauer, A G; Kluge, H J; Moore, R B; Scheidenberger, C; Schwarz, S; Sikler, G

    2004-01-01

    The masses of the noble-gas Xe isotopes with 114 $\\leq$ A $\\leq$ 123 have been directly measured for the first time. The experiments were carried out with the ISOLTRAP triple trap spectrometer at the online mass separator ISOLDE/CERN. A mass resolving power of the Penning trap spectrometer of $m/\\Delta m$ of close to a million was chosen resulting in an accuracy of $\\delta m \\leq 13$ keV for all investigated isotopes. Conflicts with existing, indirectly obtained, mass data by several standard deviations were found and are discussed. An atomic mass evaluation has been performed and the results are compared to information from laser spectroscopy experiments and to recent calculations employing an interacting boson model.

  13. Direct Measurement of Trace Elemental Mercury in Hydrocarbon Matrices by Gas Chromatography with Ultraviolet Photometric Detection.

    Science.gov (United States)

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2015-11-17

    We introduce a technique for the direct measurement of elemental mercury in light hydrocarbons such as natural gas. We determined elemental mercury at the parts-per-trillion level with high precision [photometric detection (GC-UV) at 254 nm. Our approach requires a small sample volume (1 mL) and does not rely on any form of sample preconcentration. The GC-UV separation employs an inert divinylbenzene porous layer open tubular column set to separate mercury from other components in the sample matrix. We incorporated a 10-port gas-sampling valve in the GC-UV system, which enables automated sampling, as well as back flushing capability to enhance system cleanliness and sample throughput. Total analysis time is 98% over this range.

  14. FARADAY CUP AWARD: High Sensitivity Tune Measurement using Direct Diode Detection

    CERN Document Server

    Gasior, M

    2012-01-01

    Direct Diode Detection (3D) is a technique developed at CERN initially for the LHC tune measurement system, to reach a sensitivity allowing observation of beam betatron oscillations with amplitudes below a micrometre. In this technique simple peak diode detectors are used to convert short beam pulses from a beam position pick-up into slowly varying signals. Their DC components, constituting a large background related to beam offsets, are suppressed by series capacitors, while the small signals related to beam oscillations are passed to the subsequent stages for amplification and filtering. As the demodulated beam oscillation signals are already in the kHz range, their processing is simple and they can be digitised with high resolution audio ADCs. This paper presents the history as well as the adventures of the 3D development and prototyping, along with some technical details. It documents a very efficient collaboration between CERN and Brookhaven National Laboratory (BNL), with contributions from other labora...

  15. Direct measurement of density oscillation induced by a radio-frequency wave

    International Nuclear Information System (INIS)

    Yamada, T.; Ejiri, A.; Shimada, Y.; Oosako, T.; Tsujimura, J.; Takase, Y.; Kasahara, H.

    2007-01-01

    An O-mode reflectometer at a frequency of 25.85 GHz was applied to plasmas heated by the high harmonic fast wave (21 MHz) in the TST-2 spherical tokamak. An oscillation in the phase of the reflected microwave in the rf range was observed directly for the first time. In TST-2, the rf (250 kW) induced density oscillation depends mainly on the poloidal rf electric field, which is estimated to be about 0.2 kV/m rms by the reflectometer measurement. Sideband peaks separated in frequency by ion cyclotron harmonics from 21 MHz, and peaks at ion cyclotron harmonics which are suggested to be quasimodes generated by parametric decay, were detected

  16. Calibration method based on direct radioactivity measurement for radioactive gas monitoring instruments

    International Nuclear Information System (INIS)

    Yoshida, Makoto; Ohi, Yoshihiro; Chida, Tohru; Wu, Youyang.

    1993-01-01

    A calibration method for radioactive gas monitoring instruments was studied. In the method, gaseous radioactivity standards were provided on the basis of the direct radioactivity measurement by the diffusion-in long proportional counter method (DLPC method). The radioactivity concentration of the gas mixture through a monitoring instrument was determined by sampling the known volume of the gas mixture into the proportional counter used for the DLPC method. Since oxygen in the gas mixture decreased the counting efficiency in a proportional counter, the influence on calibration was experimentally estimated. It was not serious and able to be easily corrected. By the present method, the relation between radioactivity concentration and ionization current was determined for a gas-flow ionization chamber with 1.5 l effective volume. It showed good agreement with the results in other works. (author)

  17. Combined local current distribution measurements and high resolution neutron radiography of operating direct methanol fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Alexander; Wippermann, Klaus [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy Research, IEF-3: Fuel Cells; Sanders, Tilman [RWTH Aachen (DE). Inst. for Power Electronics and Electrical Drives (ISEA); Arlt, Tobias [Helmholtz Centre Berlin (Germany). Inst. for Applied Materials

    2010-07-01

    Neutron radiography allows the investigation of the local fluid distribution in direct methanol fuel cells (DMFCs) under operating conditions. Spatial resolutions in the order of some tens of micrometers at the full test cell area are achieved. This offers the possibility to study practice-oriented, large stack cells with an active area of several hundred cm{sup 2} as well as specially designed, small test cells with an area of some cm{sup 2}. Combined studies of high resolution neutron radiography and segmented cell measurements are especially valuable, because they enable a correlation of local fluid distribution and local performance [1, 2]. The knowledge of this interdependency is essential to optimise the water management and performance respecting a homogeneous fluid, current and temperature distribution and to achieve high performance and durability of DMFCs. (orig.)

  18. Direct measurements of the velocity and thickness of ''explosively'' propagating buried molten layers in amorphous silicon

    International Nuclear Information System (INIS)

    Lowndes, D.H.; Jellison, G.E. Jr.; Pennycook, S.J.; Withrow, S.P.; Mashburn, D.N.

    1986-01-01

    Simultaneous infrared (1152 nm) and visible (633 nm) reflectivity measurements with nanosecond resolution were used to study the initial formation and subsequent motion of pulsed KrF laser-induced ''explosively'' propagating buried molten layers in ion implantation-amorphized silicon. The buried layer velocity decreases with depth below the surface, but increases with KrF laser energy density; a maximum velocity of about 14 m/s was observed, implying an undercooling-velocity relationship of approx. 14 K/(m/s). Z-contrast scanning transmission electron microscopy was used to form a direct chemical image of implanted Cu ions transported by the buried layer and showed that the final buried layer thickness was <15 nm

  19. Measurement of direct CP-violation with the experiments NA31 and NA48 at CERN

    International Nuclear Information System (INIS)

    Renk, B.

    1992-01-01

    The NA31 experiment has measured the CP violation parameter var-epsilon '/var-epsilon. The result of data collected in 1988 is Re(var-epsilon '/var-epsilon)=(1.7±1.0)x10 -3 . A preliminary result of data collected in 1989 is Re(var-epsilon '/var-epsilon)=(2.1±0.9)x10 -3 . Combining these two results with the original result from the 1986 data set we obtain Re(var-epsilon '/var-epsilon)=(2.3±0.7)x10 -3 , which is a more than three standard deviation evidence for direct CP violation. A new experiment NA48 is under construction which aims for a significant reduction of the statistical and the systematical errors in order to reach a combined error not exceeding 2x10 -4

  20. Probing surface charge potentials of clay basal planes and edges by direct force measurements.

    Science.gov (United States)

    Zhao, Hongying; Bhattacharjee, Subir; Chow, Ross; Wallace, Dean; Masliyah, Jacob H; Xu, Zhenghe

    2008-11-18

    The dispersion and gelation of clay suspensions have major impact on a number of industries, such as ceramic and composite materials processing, paper making, cement production, and consumer product formulation. To fundamentally understand controlling mechanisms of clay dispersion and gelation, it is necessary to study anisotropic surface charge properties and colloidal interactions of clay particles. In this study, a colloidal probe technique was employed to study the interaction forces between a silica probe and clay basal plane/edge surfaces. A muscovite mica was used as a representative of 2:1 phyllosilicate clay minerals. The muscovite basal plane was prepared by cleavage, while the edge surface was obtained by a microtome cutting technique. Direct force measurements demonstrated the anisotropic surface charge properties of the basal plane and edge surface. For the basal plane, the long-range forces were monotonically repulsive within pH 6-10 and the measured forces were pH-independent, thereby confirming that clay basal planes have permanent surface charge from isomorphic substitution of lattice elements. The measured interaction forces were fitted well with the classical DLVO theory. The surface potentials of muscovite basal plane derived from the measured force profiles were in good agreement with those reported in the literature. In the case of edge surfaces, the measured forces were monotonically repulsive at pH 10, decreasing with pH, and changed to be attractive at pH 5.6, strongly suggesting that the charge on the clay edge surfaces is pH-dependent. The measured force profiles could not be reasonably fitted with the classical DLVO theory, even with very small surface potential values, unless the surface roughness was considered. The surface element integration (SEI) method was used to calculate the DLVO forces to account for the surface roughness. The surface potentials of the muscovite edges were derived by fitting the measured force profiles with the

  1. Direct measurement of tritium production rate in LiPb with removed parasitic activities: Preliminary experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kuc, Tadeusz, E-mail: kuc@agh.edu.pl; Pohorecki, Władysław; Ostachowicz, Beata

    2014-10-15

    Liquid scintillation (LS) technique applied to direct measurement of tritium activity produced in LiPb eutectic in Frascati HCLL TBM mock-up neutronic experiment has been tested so far in the case of LS measurement after long period since irradiation. LiPb samples irradiated in neutron filed show, except of tritium, meaningful activity of other radioisotopes (parasitic). Parasitic activity, mainly from isotopes of lead ({sup 209}Pb, {sup 204m}Pb, {sup 203}Pb) calculated with the use of FISPACT, exceeds ca 5 times tritium activity 1.4 h after irradiation. We propose to remove disturbing radioisotopes in a chemical way to avoid long “cooling” of the irradiated samples before tritium measurement. Samples (1 g of LiPb) irradiated in reactor fast neutron flux were diluted and metallic cations removed by chemical precipitation. For this purpose we used: potassium iodide (KJ), strontium chloride (SrCl{sub 2}), APDC (C{sub 5}H{sub 8}NS{sub 2}·NH{sub 4}), NaDDTC (C{sub 5}H{sub 10}NNaS{sub 2}·3H{sub 2}O), and PAN (C{sub 15}H{sub 11}N{sub 3}O). Precipitation procedure in each case lasted ca 5–25 min, and the following filtration next 10–20 min. In each filtrate (ca 120 ml) we measured Pb concentration in total reflection X-ray fluorescence (TXRF) analyzer and parasitic activity (left after 21-day “cooling”) applying HPGe gamma spectrometer. Pb cations precipitated by SrCl{sub 2} and than by PAN lowered activity of Pb isotopes to less than 1% of the initial tritium activity. Another combination of reagents: NaDDTC followed by SrCl{sub 2} in a single and double step filtration reduced Pb concentration 10{sup 2} and 10{sup 4} times, respectively. Reduction of this order allows tritium radiometric measurement ca 3 h after irradiation with acceptable accuracy. This time can be shortened by applying correction for decay of known parasitic activity. Input of {sup 76}As and other less abundant radioisotopes can be eliminated using high purity LiPb. Tritium activity of

  2. Prevalence of advanced adenomas in small and diminutive colon polyps using direct measurement of size.

    Science.gov (United States)

    Tsai, Franklin C; Strum, Williamson B

    2011-08-01

    Most studies reporting polyp size use visual estimates. Determining the prevalence of advanced histology based on direct measurement of polyp size may help guide the management of polyps found at optical colonoscopy (OC) and CT colonography (CTC). We designed a large, prospective study to assess the prevalence of advanced adenomas based on direct measurement of polyp size by a certified pathologists' assistant as reported in the pathology report. Patients between 40 and 89 years of age who presented for screening colonoscopy were included in our study. Advanced adenomas were defined as ≥10 mm or ≥25% villous features, high grade dysplasia or cancer. Polyps were divided by size into three groups: diminutive (≤5 mm), small (6-9 mm) and large (≥10 mm). If more than one adenoma was present, the most advanced was used for analysis. We evaluated 6,905 consecutive patients referred for colonoscopy between January 2005 and December 2006. Of the 4,967 who met the inclusion criteria, the mean age was 58.8 and consisted of 59% women. Overall, 930 (18.7%) had an adenoma; 248 (5%) were advanced adenomas including 8 (0.16%) cancers. Of 89 polyps≥10 mm, 76 (85%) had advanced histology; of 247 polyps 6-9 mm, 67 (27%) were advanced; of 1,025 polyps ≤5 mm, 105 (10%) were advanced. Thus, 172 of 248 (69%) patients with advanced adenomas had small or diminutive adenomas. Our data indicate the majority (69%) of advanced adenomas are advanced adenomas (10%). These findings may help guide the management of sub-centimeter colon polyps found by OC or CTC.

  3. Developing model-making and model-breaking skills using direct measurement video-based activities

    Science.gov (United States)

    Vonk, Matthew; Bohacek, Peter; Militello, Cheryl; Iverson, Ellen

    2017-12-01

    This study focuses on student development of two important laboratory skills in the context of introductory college-level physics. The first skill, which we call model making, is the ability to analyze a phenomenon in a way that produces a quantitative multimodal model. The second skill, which we call model breaking, is the ability to critically evaluate if the behavior of a system is consistent with a given model. This study involved 116 introductory physics students in four different sections, each taught by a different instructor. All of the students within a given class section participated in the same instruction (including labs) with the exception of five activities performed throughout the semester. For those five activities, each class section was split into two groups; one group was scaffolded to focus on model-making skills and the other was scaffolded to focus on model-breaking skills. Both conditions involved direct measurement videos. In some cases, students could vary important experimental parameters within the video like mass, frequency, and tension. Data collected at the end of the semester indicate that students in the model-making treatment group significantly outperformed the other group on the model-making skill despite the fact that both groups shared a common physical lab experience. Likewise, the model-breaking treatment group significantly outperformed the other group on the model-breaking skill. This is important because it shows that direct measurement video-based instruction can help students acquire science-process skills, which are critical for scientists, and which are a key part of current science education approaches such as the Next Generation Science Standards and the Advanced Placement Physics 1 course.

  4. Direct assessment of lung function in COPD using CT densitometric measures

    International Nuclear Information System (INIS)

    Gu, Suicheng; Leader, Joseph; Gur, David; Pu, Jiantao; Zheng, Bin; Chen, Qihang; Sciurba, Frank; Kminski, Naftali

    2014-01-01

    To investigate whether lung function in patients with chronic obstructive pulmonary disease (COPD) can be directly predicted using CT densitometric measures and assess the underlying prediction errors as compared with the traditional spirometry-based measures. A total of 600 CT examinations were collected from a COPD study. In addition to the entire lung volume, the extent of emphysema depicted in each CT examination was quantified using density mask analysis (densitometry). The partial least square regression was used for constructing the prediction model, where a repeated random split-sample validation was employed. For each split, we randomly selected 400 CT exams for training (regression) purpose and the remaining 200 exams for assessing performance in prediction of lung function (e.g., FEV1 and FEV1/FVC) and disease severity. The absolute and percentage errors as well as their standard deviations were computed. The averaged percentage errors in prediction of FEV1, FEV1/FVC%, TLC, RV/TLC% and DLco% predicted were 33%, 17%, 9%, 18% and 23%, respectively. When classifying the exams in terms of disease severity grades using the CT measures, 37% of the subjects were correctly classified with no error and 83% of the exams were either correctly classified or classified into immediate neighboring categories. The linear weighted kappa and quadratic weighted kappa were 0.54 (moderate agreement) and 0.72 (substantial agreement), respectively. Despite the existence of certain prediction errors in quantitative assessment of lung function, the CT densitometric measures could be used to relatively reliably classify disease severity grade of COPD patients in terms of GOLD. (paper)

  5. Edge effects in four-point direct current potential drop measurements on metal plates

    International Nuclear Information System (INIS)

    Lu, Y; Bowler, N; Bowler, J R; Huang, Y

    2009-01-01

    Four-point direct current potential drop (DCPD) measurements are commonly used to measure the conductivity (or resistivity) of semiconductors and ferrous or non-ferrous metals. The measured electrical potential difference is often interpreted in terms of analytic expressions developed for large plates that are either 'thin' or 'thick' relative to the probe length. It is well known that the presence of the back surface of a plate leads to a solution expressed in terms of an infinite series representing the current source and its images. This approach can be generalized to account for multiple surfaces in order to obtain a solution for a finite plate, but convergence of the series is poor when the plate dimensions are similar to or smaller than the separation of the current injection and extraction points. Here, Fourier series representations of the infinite sums are obtained. It is shown that the Fourier series converge with many fewer terms than the series obtained from image theory, for plates with dimensions similar to or smaller than the separation of the current injection and extraction points. Comparing calculated results for the potential drop obtained by a four-point probe centred on finite plates of varying dimension, with those for a probe in contact with a large (laterally infinite) plate, estimates are given of the uncertainty due to edge effects in measurements on small plates interpreted using analytic formulae developed for large plates. It is also shown that these uncertainties due to edge effects are reduced, for a given plate size, if the probe pick-up points are moved closer to the current injection points, rather than adopting the common arrangement in which the four probe points are equally spaced. Calculated values of DCPD are compared with experimental data taken on aluminium and spring-steel plates of various sizes and excellent agreement is obtained.

  6. Edge effects in four-point direct current potential drop measurements on metal plates

    Science.gov (United States)

    Lu, Y.; Bowler, N.; Bowler, J. R.; Huang, Y.

    2009-07-01

    Four-point direct current potential drop (DCPD) measurements are commonly used to measure the conductivity (or resistivity) of semiconductors and ferrous or non-ferrous metals. The measured electrical potential difference is often interpreted in terms of analytic expressions developed for large plates that are either 'thin' or 'thick' relative to the probe length. It is well known that the presence of the back surface of a plate leads to a solution expressed in terms of an infinite series representing the current source and its images. This approach can be generalized to account for multiple surfaces in order to obtain a solution for a finite plate, but convergence of the series is poor when the plate dimensions are similar to or smaller than the separation of the current injection and extraction points. Here, Fourier series representations of the infinite sums are obtained. It is shown that the Fourier series converge with many fewer terms than the series obtained from image theory, for plates with dimensions similar to or smaller than the separation of the current injection and extraction points. Comparing calculated results for the potential drop obtained by a four-point probe centred on finite plates of varying dimension, with those for a probe in contact with a large (laterally infinite) plate, estimates are given of the uncertainty due to edge effects in measurements on small plates interpreted using analytic formulae developed for large plates. It is also shown that these uncertainties due to edge effects are reduced, for a given plate size, if the probe pick-up points are moved closer to the current injection points, rather than adopting the common arrangement in which the four probe points are equally spaced. Calculated values of DCPD are compared with experimental data taken on aluminium and spring-steel plates of various sizes and excellent agreement is obtained.

  7. SO2 plume height retrieval from direct fitting of GOME-2 backscattered radiance measurements

    Science.gov (United States)

    van Gent, J.; Spurr, R.; Theys, N.; Lerot, C.; Brenot, H.; Van Roozendael, M.

    2012-04-01

    The use of satellite measurements for SO2 monitoring has become an important aspect in the support of aviation control. Satellite measurements are sometimes the only information available on SO2 concentrations from volcanic eruption events. The detection of SO2 can furthermore serve as a proxy for the presence of volcanic ash that poses a possible hazard to air traffic. In that respect, knowledge of both the total vertical column amount and the effective altitude of the volcanic SO2 plume is valuable information to air traffic control. The Belgian Institute for Space Aeronomy (BIRA-IASB) hosts the ESA-funded Support to Aviation Control Service (SACS). This system provides Volcanic Ash Advisory Centers (VAACs) worldwide with near real-time SO2 and volcanic ash data, derived from measurements from space. We present results from our algorithm for the simultaneous retrieval of total vertical columns of O3 and SO2 and effective SO2 plume height from GOME-2 backscattered radiance measurements. The algorithm is an extension to the GODFIT direct fitting algorithm, initially developed at BIRA-IASB for the derivation of improved total ozone columns from satellite data. The algorithm uses parameterized vertical SO2 profiles which allow for the derivation of the peak height of the SO2 plume, along with the trace gas total column amounts. To illustrate the applicability of the method, we present three case studies on recent volcanic eruptions: Merapi (2010), Grímsvotn (2011), and Nabro (2011). The derived SO2 plume altitude values are validated with the trajectory model FLEXPART and with aerosol altitude estimations from the CALIOP instrument on-board the NASA A-train CALIPSO platform. We find that the effective plume height can be obtained with a precision as fine as 1 km for moderate and strong volcanic events. Since this is valuable information for air traffic, we aim at incorporating the plume height information in the SACS system.

  8. Direct measurement of NO3 radical reactivity in a boreal forest

    Science.gov (United States)

    Liebmann, Jonathan; Karu, Einar; Sobanski, Nicolas; Schuladen, Jan; Ehn, Mikael; Schallhart, Simon; Quéléver, Lauriane; Hellen, Heidi; Hakola, Hannele; Hoffmann, Thorsten; Williams, Jonathan; Fischer, Horst; Lelieveld, Jos; Crowley, John N.

    2018-03-01

    We present the first direct measurements of NO3 reactivity (or inverse lifetime, s-1) in the Finnish boreal forest. The data were obtained during the IBAIRN campaign (Influence of Biosphere-Atmosphere Interactions on the Reactive Nitrogen budget) which took place in Hyytiälä, Finland during the summer/autumn transition in September 2016. The NO3 reactivity was generally very high with a maximum value of 0.94 s-1 and displayed a strong diel variation with a campaign-averaged nighttime mean value of 0.11 s-1 compared to a daytime value of 0.04 s-1. The highest nighttime NO3 reactivity was accompanied by major depletion of canopy level ozone and was associated with strong temperature inversions and high levels of monoterpenes. The daytime reactivity was sufficiently large that reactions of NO3 with organic trace gases could compete with photolysis and reaction with NO. There was no significant reduction in the measured NO3 reactivity between the beginning and end of the campaign, indicating that any seasonal reduction in canopy emissions of reactive biogenic trace gases was offset by emissions from the forest floor. Observations of biogenic hydrocarbons (BVOCs) suggested a dominant role for monoterpenes in determining the NO3 reactivity. Reactivity not accounted for by in situ measurement of NO and BVOCs was variable across the diel cycle with, on average, ≈ 30 % missing during nighttime and ≈ 60 % missing during the day. Measurement of the NO3 reactivity at various heights (8.5 to 25 m) both above and below the canopy, revealed a strong nighttime, vertical gradient with maximum values closest to the ground. The gradient disappeared during the daytime due to efficient vertical mixing.

  9. Directly measuring melt at a vertical face tidewater glacier: is it possible?

    Science.gov (United States)

    Sutherland, D.; Amundson, J. M.; Duncan, D.; Jackson, R. H.; Kienholz, C.; Motyka, R. J.; Nash, J. D.

    2017-12-01

    Direct observations of melt on the underwater portion of tidewater glaciers have proved elusive, mostly due to the inherent dangers of making measurements next to a calving ice front. Additionally, the melting process itself is often masked by large ice speeds, variable calving across the glacier front, and enhanced melting due to rising subglacial discharge plumes. Here, we use repeat multibeam sonar images of LeConte Glacier to assess the possibility of measuring terminus melt in situ. LeConte Glacier is a fast-moving tidewater system in southeast Alaska with ice speeds of 25 m d-1 and previously estimated submarine melting that accounts for 50% of ice loss at the front. In August 2016, May 2017, and September 2017, we conducted intensive fieldwork at the 1.5 km long, 250 m deep glacier front, collecting dozens of repeat multibeam images of the underwater terminus. Combined with coincident time-lapse photography and surface radar measurements, we attempt to disentangle the ambient melt at the glacier face from ice motion and calving. We use a suite of oceanographic observations of the emerging subglacial discharge plume to separate portions of the glacier front that show evidence of enhanced melting versus portions outside of the affected plume areas. We find a complex, time-varying geometry, with regions of undercutting, overcutting, and large discharge channels. Measurements like these are critical to i) improving numerical model parameterizations of coupled glacier-ocean interactions and ii) developing a process-based understanding of how the literal ice-ocean boundary evolves in time and space.

  10. Direct spectrometry: a new alternative for measuring the fluorescence of composite resins and dental tissues.

    Science.gov (United States)

    da Silva, Tm; de Oliveira, Hpm; Severino, D; Balducci, I; Huhtala, Mfrl; Gonçalves, Sep

    2014-01-01

    The aim of this study was to evaluate the fluorescence intensity of different composite resins and compare those values with the fluorescence intensity of dental tissues. Different composite resins were used to make 10 discs (2 mm in depth and 4 mm in diameter) of each brand, divided into groups: 1) Z (Filtek Z350, 3M ESPE), 2) ES (Esthet-X, Dentsply), 3) A (Amelogen Plus, Ultradent), 4) DVS (Durafill-VS, Heraeus Kulzer) with 2 mm composite resin for enamel (A2), 5) OES ([Esthet-X] opaque-OA [1 mm] + enamel-A2 [1 mm]); 6) ODVSI ([Charisma-Opal/Durafill-VSI], opaque-OM (1 mm) + translucent [1mm]), and 7) DVSI ([Durafill- VSI] translucent [2 mm]). Dental tissue specimens were obtained from human anterior teeth cut in a mesiodistal direction to obtain enamel, dentin, and enamel/dentin samples (2 mm). The fluorescence intensity of specimens was directly measured using an optic fiber associated with a spectrometer (Ocean Optics USB 4000) and recorded in graphic form (Origin 8.0 program). Data were submitted to statistical analysis using Dunnet, Tukey, and Kruskall-Wallis tests. Light absorption of the composite resins was obtained in a spectral range from 250 to 450 nm, and that of dental tissues was between 250 and 300 nm. All composite resins were excited at 398 nm and exhibited maximum emissions of around 485 nm. Fluorescence intensity values for all of the resins showed statistically significant differences (measured in arbitrary units [AUs]), with the exception of groups Z and DVS. Group DVSI had the highest fluorescence intensity values (13539 AU), followed by ODVS (10440 AU), DVS (10146 AU), ES (3946 AU), OES (3841 AU), A (3540 AU), and Z (1146 AU). The fluorescence intensity values for the composite resins differed statistically from those of dental tissues (E=1380 AU; D=6262 AU; E/D=3251 AU). The opacity interfered with fluorescence intensity, and group Z demonstrated fluorescence intensity values closest to that of tooth enamel. It is concluded that the

  11. Direct rotating ring-disk measurement of the sodium borohydride diffusion coefficient in sodium hydroxide solutions

    Energy Technology Data Exchange (ETDEWEB)

    Chatenet, M. [Laboratoire d' Electrochimie et de Physico-chimie des Materiaux et des Interfaces, LEPMI, UMR 5631 CNRS/Grenoble-INP/UJF, 1130 rue de la piscine, BP75, 38402 Saint Martin d' Heres Cedex (France)], E-mail: Marian.Chatenet@phelma.grenoble-inp.fr; Molina-Concha, M.B. [Laboratoire d' Electrochimie et de Physico-chimie des Materiaux et des Interfaces, LEPMI, UMR 5631 CNRS/Grenoble-INP/UJF, 1130 rue de la piscine, BP75, 38402 Saint Martin d' Heres Cedex (France); El-Kissi, N. [Laboratoire de Rheologie, UMR 5520 CNRS/Grenoble-INP/UJF, 1301 rue de la piscine, 38041 Grenoble Cedex 9 (France); Parrour, G.; Diard, J.-P. [Laboratoire d' Electrochimie et de Physico-chimie des Materiaux et des Interfaces, LEPMI, UMR 5631 CNRS/Grenoble-INP/UJF, 1130 rue de la piscine, BP75, 38402 Saint Martin d' Heres Cedex (France)

    2009-07-15

    This paper presents the experimental determination of the diffusion coefficient of borohydride anion and solution kinematic viscosity for a large panel of NaOH + NaBH{sub 4} electrolytic solutions relevant for use as anolyte in Direct Borohydride Fuel Cells (DBFC). The diffusion coefficients have been measured by the transit-time technique on gold rotating ring-disk electrodes, and verified using other classical techniques reported in the literature, namely the Levich method and Electrochemical Impedance Spectroscopy on a gold RDE, or chronoamperometry at a gold microdisk. The agreement between these methods is generally good. The diffusion coefficients measured from the RRDE technique are however ca. twice larger than those previously reported in the literature (e.g. ca. 3 x 10{sup -5} cm{sup 2} s{sup -1} in 1 M NaOH + 0.01 M NaBH{sub 4} at 25 deg. C in the present study vs. ca. 1.6 x 10{sup -5} cm{sup 2} s{sup -1} in 1 M NaOH + 0.02 M NaBH{sub 4} at 30 deg. C in the literature, as measured by chronoamperometry at a gold microsphere), which is thoroughly discussed. Our measurements using chronoamperometry at a gold microdisk showed that such technique can yield diffusion coefficient values below what expected. The origin of such finding is explained in the frame of the formation of both a film of boron-oxide(s) at the surface of the (static) gold microdisk and the generation of H{sub 2} bubbles at the electrode surface (as a result of the heterogeneous hydrolysis at Au), which alter the access to the electrode surface and thus prevents efficient measurements. Such film formation and H{sub 2} bubbles generation is not so much of an issue for rotating electrodes thanks to the convection of electrolyte which sweeps the electrode surface. In addition, should such film be present, the transit-time determination technique on a RRDE displays the advantage of not being very sensible to its presence: the parameter measured is the time taken by a perturbation generated the

  12. Direct rotating ring-disk measurement of the sodium borohydride diffusion coefficient in sodium hydroxide solutions

    International Nuclear Information System (INIS)

    Chatenet, M.; Molina-Concha, M.B.; El-Kissi, N.; Parrour, G.; Diard, J.-P.

    2009-01-01

    This paper presents the experimental determination of the diffusion coefficient of borohydride anion and solution kinematic viscosity for a large panel of NaOH + NaBH 4 electrolytic solutions relevant for use as anolyte in Direct Borohydride Fuel Cells (DBFC). The diffusion coefficients have been measured by the transit-time technique on gold rotating ring-disk electrodes, and verified using other classical techniques reported in the literature, namely the Levich method and Electrochemical Impedance Spectroscopy on a gold RDE, or chronoamperometry at a gold microdisk. The agreement between these methods is generally good. The diffusion coefficients measured from the RRDE technique are however ca. twice larger than those previously reported in the literature (e.g. ca. 3 x 10 -5 cm 2 s -1 in 1 M NaOH + 0.01 M NaBH 4 at 25 deg. C in the present study vs. ca. 1.6 x 10 -5 cm 2 s -1 in 1 M NaOH + 0.02 M NaBH 4 at 30 deg. C in the literature, as measured by chronoamperometry at a gold microsphere), which is thoroughly discussed. Our measurements using chronoamperometry at a gold microdisk showed that such technique can yield diffusion coefficient values below what expected. The origin of such finding is explained in the frame of the formation of both a film of boron-oxide(s) at the surface of the (static) gold microdisk and the generation of H 2 bubbles at the electrode surface (as a result of the heterogeneous hydrolysis at Au), which alter the access to the electrode surface and thus prevents efficient measurements. Such film formation and H 2 bubbles generation is not so much of an issue for rotating electrodes thanks to the convection of electrolyte which sweeps the electrode surface. In addition, should such film be present, the transit-time determination technique on a RRDE displays the advantage of not being very sensible to its presence: the parameter measured is the time taken by a perturbation generated the disk to reach the ring trough a distance several orders

  13. Direct measurement of the total decay width of the top quark.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2013-11-15

    We present a measurement of the total decay width of the top quark using events with top-antitop quark pair candidates reconstructed in the final state with one charged lepton and four or more hadronic jets. We use the full Tevatron run II data set of sqrt[s]=1.96  TeV proton-antiproton collisions recorded by the CDF II detector. The top quark mass and the mass of the hadronically decaying W boson are reconstructed for each event and compared with distributions derived from simulated signal and background samples to extract the top quark width (Γtop) and the energy scale of the calorimeter jets with in situ calibration. For a top quark mass Mtop=172.5  GeV/c2, we find 1.10<Γtop<4.05  GeV at 68% confidence level, which is in agreement with the standard model expectation of 1.3 GeV and is the most precise direct measurement of the top quark width to date.

  14. Using linear time-invariant system theory to estimate kinetic parameters directly from projection measurements

    International Nuclear Information System (INIS)

    Zeng, G.L.; Gullberg, G.T.

    1995-01-01

    It is common practice to estimate kinetic parameters from dynamically acquired tomographic data by first reconstructing a dynamic sequence of three-dimensional reconstructions and then fitting the parameters to time activity curves generated from the time-varying reconstructed images. However, in SPECT, the pharmaceutical distribution can change during the acquisition of a complete tomographic data set, which can bias the estimated kinetic parameters. It is hypothesized that more accurate estimates of the kinetic parameters can be obtained by fitting to the projection measurements instead of the reconstructed time sequence. Estimation from projections requires the knowledge of their relationship between the tissue regions of interest or voxels with particular kinetic parameters and the project measurements, which results in a complicated nonlinear estimation problem with a series of exponential factors with multiplicative coefficients. A technique is presented in this paper where the exponential decay parameters are estimated separately using linear time-invariant system theory. Once the exponential factors are known, the coefficients of the exponentials can be estimated using linear estimation techniques. Computer simulations demonstrate that estimation of the kinetic parameters directly from the projections is more accurate than the estimation from the reconstructed images

  15. Determination of microturbulence enhanced electron collisionality in magnetized coaxial accelerator channels by direct magnetic field measurement

    International Nuclear Information System (INIS)

    Black, D.C.; Mayo, R.M.; Caress, R.W.

    1997-01-01

    A miniature magnetic probe array, consisting of 10 spatially separated coils, has been used to obtain profile information on the time varying magnetic field within the 2.54 cm wide flow channel of the coaxial plasma source experiment (CPS-1) [R. M. Mayo et al., Plasma Sources Sci. Technol. 4, 47 (1995)]. The magnetic field data have been used, together with a resistive, Hall magnetohydrodynamic (MHD) model of applied field distortion by the flowing plasma, to obtain estimates of the microturbulent enhancement to electron collisionality within the CPS-1 flow channel. These measurements provide direct experimental evidence of anomalous electron collisionality, a previously predicted effect in these devices. The anomaly parameter, a=ν an /ν cl , determined both from the distortion of contours of constant magnetic flux, and from local B θ and B z measurements scales with the classical electron magnetization parameter (Ω cl =ω ce /ν e cl ), indicating that collisionality plays a strong role in determining the level of anomalous transport in the plasma. When this anomaly parameter scaling is cast in terms of the ratio ν e cl /ω lh , it is found that the resistivity enhancement scales with ν e cl /ω lh , and becomes significant at ν e cl /ω lh ≤1, suggesting that a lower hybrid drift instability may be the responsible mechanism for enhanced transport. copyright 1997 American Institute of Physics

  16. External meeting: KATRIN - direct measurement of neutrino masses with sub-eV sensitivity

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY - ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 - Tél : 022 379 62 73 - Fax: 022 379 69 92 Wednesday 18 April 2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium KATRIN - direct measurement of neutrino masses with sub-eV sensitivity by Prof. Guido Drexlin, Karlsruhe Institute of Technology KIT The major scientific objective of the international Karlsruhe Tritum Neutrino (KATRIN) Experiment is the model independent measurement of the electron neutrino mass in tritium beta decay with a sensitivity of 200 meV. In the cosmological context, this allows an investigation of whether massive relic neutrinos left over from the Big Bang play a specific role as hot dark matter in the evolution of large scale structures of the universe. In particle physics KATRIN will allow for discrimination between different neutrino mass models (either of quasi-degenerate or hierarchical pattern).The key components of KATRIN comprise...

  17. CMOS direct time interval measurement of long-lived luminescence lifetimes.

    Science.gov (United States)

    Yao, Lei; Yung, Ka Yi; Cheung, Maurice C; Chodavarapu, Vamsy P; Bright, Frank V

    2011-01-01

    We describe a Complementary Metal-Oxide Semiconductor (CMOS) Direct Time Interval Measurement (DTIM) Integrated Circuit (IC) to detect the decay (fall) time of the luminescence emission when analyte-sensitive luminophores are excited with an optical pulse. The CMOS DTIM IC includes 14 × 14 phototransistor array, transimpedance amplifier, regulated gain amplifier, fall time detector, and time-to-digital convertor. We examined the DTIM system to measure the emission lifetime of oxygen-sensitive luminophores tris(4,7-diphenyl-1, 10-phenanthroline) ruthenium(II) ([Ru(dpp)(3)](2+)) encapsulated in sol-gel derived xerogel thin-films. The DTIM system fabricated using TSMC 0.35 μm process functions to detect lifetimes from 4 μs to 14.4 μs but can be tuned to detect longer lifetimes. The system provides 8-bit digital output proportional to lifetimes and consumes 4.5 mW of power with 3.3 V DC supply. The CMOS system provides a useful platform for the development of reliable, robust, and miniaturized optical chemical sensors.

  18. Direct Reconstruction of Two-Dimensional Currents in Thin Films from Magnetic-Field Measurements

    Science.gov (United States)

    Meltzer, Alexander Y.; Levin, Eitan; Zeldov, Eli

    2017-12-01

    An accurate determination of microscopic transport and magnetization currents is of central importance for the study of the electric properties of low-dimensional materials and interfaces, of superconducting thin films, and of electronic devices. Current distribution is usually derived from the measurement of the perpendicular component of the magnetic field above the surface of the sample, followed by numerical inversion of the Biot-Savart law. The inversion is commonly obtained by deriving the current stream function g , which is then differentiated in order to obtain the current distribution. However, this two-step procedure requires filtering at each step and, as a result, oversmooths the solution. To avoid this oversmoothing, we develop a direct procedure for inversion of the magnetic field that avoids use of the stream function. This approach provides enhanced accuracy of current reconstruction over a wide range of noise levels. We further introduce a reflection procedure that allows for the reconstruction of currents that cross the boundaries of the measurement window. The effectiveness of our approach is demonstrated by several numerical examples.

  19. High temperature thermal conductivity measurements of UO2 by Direct Electrical Heating. Final report

    International Nuclear Information System (INIS)

    Bassett, B.

    1980-10-01

    High temperature properties of reactor type UO 2 pellets were measured using a Direct Electrical Heating (DEH) Facility. Modifications to the experimental apparatus have been made so that successful and reproducible DEH runs may be carried out while protecting the pellets from oxidation at high temperature. X-ray diffraction measurements on the UO 2 pellets have been made before and after runs to assure that sample oxidation has not occurred. A computer code has been developed that will model the experiment using equations that describe physical properties of the material. This code allows these equations to be checked by comparing the model results to collected data. The thermal conductivity equation for UO 2 proposed by Weilbacher has been used for this analysis. By adjusting the empirical parameters in Weilbacher's equation, experimental data can be matched by the code. From the several runs analyzed, the resulting thermal conductivity equation is lambda = 1/4.79 + 0.0247T/ + 1.06 x 10 -3 exp[-1.62/kT/] - 4410. exp[-3.71/kT/] where lambda is in w/cm K, k is the Boltzman constant, and T is the temperature in Kelvin

  20. Measuring and explaining multi-directional inefficiency in the Malaysian dairy industry.

    Science.gov (United States)

    Mohd Suhaimi, Nurul Aisyah Binti; de Mey, Yann; Oude Lansink, Alfons

    2017-01-01

    The purpose of this paper is to measure the technical inefficiency of dairy farms and subsequently investigate the factors affecting technical inefficiency in the Malaysian dairy industry. This study uses multi-directional efficiency analysis to measure the technical inefficiency scores on a sample of 200 farm observations and single-bootstrap truncated regression model to define factors affecting technical inefficiency. Managerial and program inefficiency scores are presented for intensive and semi-intensive production systems. The results reveal marked differences in the inefficiency scores across inputs and between production systems. Intensive systems generally have lowest managerial and program inefficiency scores in the Malaysian dairy farming sector. Policy makers could use this information to advise dairy farmers to convert their farming system to the intensive system. The results suggest that the Malaysian Government should redefine its policy for providing farm finance and should target young farmers when designing training and extension programs in order to improve the performance of the dairy sector. The existing literature on Southeast Asian dairy farming has neither focused on investigating input-specific efficiency nor on comparing managerial and program efficiency. This paper aims to fill this gap.

  1. Direct measurement of the Concurrence of spin-entangled states in a cavity–quantum dot system

    International Nuclear Information System (INIS)

    Dong, Ping; Liu, Jun; Zhang, Li-Hua; Cao, Zhuo-Liang

    2016-01-01

    A scheme for implementing the direct measurement of Concurrence is given in a cavity–quantum dot system. The scenario not only can directly measure the Concurrence of two-spin pure entangled state, but also suitable for the case of mixed state. More importantly, all of the operations are of geometric nature, which depend on the cavity-state-free evolution and can be robust against random operation errors. Our scheme provided an alternative method for directly measuring the degree of entanglement in solid-state system.

  2. Methods for Specific Electrode Resistance Measurement during Transcranial Direct Current Stimulation

    Science.gov (United States)

    Khadka, Niranjan; Rahman, Asif; Sarantos, Chris; Truong, Dennis Q.; Bikson, Marom

    2014-01-01

    Background Transcranial Direct Current Stimulation (tDCS) is investigated to treat a wide range of neuropsychiatric disorders, for rehabilitation, and for enhancing cognitive performance. The monitoring of electrode resistance before and during tDCS is considered important for tolerability and safety, where an unusually high resistance is indicative of undesired electrode or poor skin contact conditions. Conventional resistance measurement methods do not isolate individual electrode resistance but rather measures overall voltage. Moreover, for HD-tDCS devices, cross talk across electrodes makes concurrent resistance monitoring unreliable. Objective We propose a novel method for monitoring of the individual electrode resistance during tDCS, using a super-position of direct current with a test-signal (low-intensity and low-frequency sinusoids with electrode– specific frequencies) and a single sentinel electrode (not used for DC). Methods To validate this methodology, we developed lumped-parameter models of two and multi-electrode tDCS. Approaches with and without a sentinel electrode were solved and underlying assumptions identified. Assumptions were tested and parameterized in healthy participants using forearm stimulation combining tDCS (2 mA) and sinusoidal test-signals (38 μA and 76 μA peak to peak at 1 Hz, 10 Hz, and 100 Hz) and an in vitro test (where varied electrode failure modes were created). DC and AC component voltages across the electrodes were compared and participants were asked to rate subjective pain. Results A sentinel electrode is required to isolate electrode resistance in a two-electrode tDCS system. For multi-electrode resistance tracking, cross talk was aggravated with electrode proximity and current/resistance mismatches, but could be corrected using proposed approaches. Average voltage and average pain scores were not significantly different across test current intensities and frequencies (two-way repeated measures ANOVA) indicating the

  3. Direct interferometric measurement of the atomic dipole phase in high-order harmonic generation

    International Nuclear Information System (INIS)

    Chiara Corsi; Angela Pirri; Emiliano Sali

    2006-01-01

    Complete test of publication follows. For low gas densities and negligible ionization, the so-called atomic dipole phase, connected with the electronic dynamics involved in the generation process, is the main source of phase modulation and incoherence of high-order harmonics. To accurately determine these laser-intensity-induced phase shifts is therefore of great importance, both for the possible spectroscopic applications of harmonics and for the controlled generation of attosecond pulses. In a semiclassical description, only two electronic trajectories contribute to generate plateau harmonics during each pump optical half-cycle. Electrons appearing in the continuum by tunnel ionization may follow two different quantum paths, namely a long (l) and a short (s) trajectory before recombination. According to the SFA approximation, the harmonic of q th order acquires a phase proportional to the electronic classical action, and simply given by: ψ 0 j (r,t) -α q j I(r,t) with j = l, s where α q j are non-linear phase coefficients, roughly proportional to the time that the originating electron spends in the continuum before recombination. The space and time variation of the laser intensity (I(r,t), causes just a little phase modulation for the s-trajectory harmonic component, while the l-trajectory component becomes strongly chirped and spatially defocused; this gives rise to two spatially-separated regions having different temporal coherence. Here we report the first direct measurement of such atomic dipole phase in the process of high-order harmonic generation. Differently from previous measurements based in the most natural way, i.e., by interferometry. Two phase-locked pump pulses generate two phase-locked harmonic pulses in two nearby positions in a gas jet; one of them is used as a fixed phase reference while the generating intensity of the other is varied. The shift of the XUV interference fringes observed in the far field then gives a direct estimate of the

  4. A gateway to new physics. Direct measurement of the top Yukawa coupling to the Higgs boson

    Energy Technology Data Exchange (ETDEWEB)

    Bruscino, Nello

    2017-05-15

    The top quark has the largest Yukawa coupling in the Standard Model, is the main contribution to the Higgs mass m{sub H} corrections and defines the evolution of the Higgs effective potential with the energy, together with m{sub H}. It can be directly measured through the associated production process pp → t anti tH. Two searches for this process are described in this thesis, using data collected with the ATLAS detector at the Large Hadron Collider. The fully hadronic analysis is performed with data corresponding to an integrated luminosity of 20.3 fb{sup -1} at a centre-of-mass energy of √(s)=8 TeV and uses a boosted decision tree algorithm to discriminate between signal and background: the dominant multijet background is estimated using a data-driven method. An upper limit of 6.4(5.4) times the Standard Model cross section is observed (expected) at 95% confidence level and a best-fit value of 1.6±2.6 for the signal strength μ{sub t} {sub anti} {sub tH}=σ{sub t} {sub anti} {sub tH}{sup obs}/σ{sub t} {sub anti} {sub tH}{sup SM} is measured. The multilepton analysis uses data collected at √(s)=13 TeV, corresponding to an integrated luminosity of 36.5 fb{sup -1}. Events with exactly three leptons are selected and a boosted decision tree is also exploited. The major sources of background are estimated using a simultaneous fit technique, which determines their normalisations in three control regions. An upper limit of 2.3(1.7) times the Standard Model cross section is observed (expected) at 95% confidence level and a best-fit value of 0.68{sup +0.89}{sub -0.68} for μ{sub t} {sub anti} {sub tH} is measured.

  5. In situ Probe Microphone Measurement for Testing the Direct Acoustical Cochlear Stimulator

    Directory of Open Access Journals (Sweden)

    Christof Stieger

    2017-08-01

    Full Text Available Hypothesis: Acoustical measurements can be used for functional control of a direct acoustic cochlear stimulator (DACS.Background: The DACS is a recently released active hearing implant that works on the principle of a conventional piston prosthesis driven by the rod of an electromagnetic actuator. An inherent part of the DACS actuator is a thin titanium diaphragm that allows for movement of the stimulation rod while hermetically sealing the housing. In addition to mechanical stimulation, the actuator emits sound into the mastoid cavity because of the motion of the diaphragm.Methods: We investigated the use of the sound emission of a DACS for intra-operative testing. We measured sound emission in the external auditory canal (PEAC and velocity of the actuators stimulation rod (Vact in five implanted ears of whole-head specimens. We tested the influence various positions of the loudspeaker and a probe microphone on PEAC and simulated implant malfunction in one example.Results: Sound emission of the DACS with a signal-to-noise ratio >10 dB was observed between 0.5 and 5 kHz. Simulated implant misplacement or malfunction could be detected by the absence or shift in the characteristic resonance frequency of the actuator. PEAC changed by <6 dB for variations of the microphone and loudspeaker position.Conclusion: Our data support the feasibility of acoustical measurements for in situ testing of the DACS implant in the mastoid cavity as well as for post-operative monitoring of actuator function.

  6. Direct measurement of acid efflux from isolated guinea pig pancreatic ducts.

    Science.gov (United States)

    Hootman, Seth R; Hobbs, Errett C; Luckie, Douglas B

    2005-05-01

    The current studies used the technique of microphysiometry to directly determine the effects of stimulators and inhibitors of pancreatic duct secretion on acid efflux from isolated pancreatic ducts. Main and interlobular ducts were isolated from guinea pig pancreata by collagenase digestion and manual selection. Segments were placed in the chambers of a microphysiometer, which uses a silicon chip-based, light-addressable potentiometric sensor to determine the proton concentration in the superfusing solution. Isolated ducts were superfused with a low buffer capacity Ringer's solution at 37 degrees C and the extracellular acidification rate (EAR) was determined by computer-directed protocols. A survey of potential agonists demonstrated that both secretin and the cholinomimetic, carbachol, dramatically increased EAR, with EC50 of 3 nmol/L and 0.6 mumol/L, respectively. The changes in EAR induced by both secretagogues were rapid, peaking within 4-6 minutes, and then declining to a level below the peak but above basal EAR. The enhanced EAR was maintained for at least 30 minutes in the presence of either secretagogue. More modest increases in EAR were evoked by bombesin, substance P, and vasoactive intestinal peptide (VIP). Cholecystokinin and isoproterenol caused no significant change in pancreatic duct EAR. A combination of amiloride and bafilomycin A1, inhibitors, respectively, of Na/H exchange and of vacuolar type H-ATPase activity, caused a dramatic drop in EAR but did not fully inhibit the increase in EAR elicited by carbachol, suggesting that other mechanisms may contribute to agonist-stimulated EAR of pancreatic ducts. Thus, the results support the use of microphysiometry as a tool to study pancreatic duct physiology and in particular a method to measure acid efflux from the serosal surface.

  7. Estimates of rates and errors for measurements of direct-γ and direct-γ + jet production by polarized protons at RHIC

    International Nuclear Information System (INIS)

    Beddo, M.E.; Spinka, H.; Underwood, D.G.

    1992-01-01

    Studies of inclusive direct-γ production by pp interactions at RHIC energies were performed. Rates and the associated uncertainties on spin-spin observables for this process were computed for the planned PHENIX and STAR detectors at energies between √s = 50 and 500 GeV. Also, rates were computed for direct-γ + jet production for the STAR detector. The goal was to study the gluon spin distribution functions with such measurements. Recommendations concerning the electromagnetic calorimeter design and the need for an endcap calorimeter for STAR are made

  8. Measurements of delayed hydride cracking propagation rate in the radial direction of Zircaloy-2 cladding tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, T., E-mail: kubo@nfd.co.jp [Nippon Nuclear Fuel Development Co., Ltd., 2163 Narita-cho, Oarai-machi, Ibaraki 311-1313 (Japan); Kobayashi, Y. [M.O.X. Co., Ltd., 1828-520 Hirasu-cho, Mito, Ibaraki 311-0853 (Japan); Uchikoshi, H. [Nippon Nuclear Fuel Development Co., Ltd., 2163 Narita-cho, Oarai-machi, Ibaraki 311-1313 (Japan)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The delayed hydride cracking (DHC) velocity of Zircaloy-2 was measured. Black-Right-Pointing-Pointer The velocity followed the Arrhenius law up to 270 Degree-Sign C. Activation energy was 49 kJ/mol. Black-Right-Pointing-Pointer The threshold stress intensity factor for the DHC was from 4 to 6 MPa m{sup 1/2}. Black-Right-Pointing-Pointer An increase in material strength accelerated the DHC. Black-Right-Pointing-Pointer Precipitation and fracture of hydrides at a crack tip is responsible for the DHC. - Abstract: Delayed hydride cracking (DHC) tests of Zircaloy-2 cladding tubes were performed in the chamber of a scanning electron microscope (SEM) to directly observe the crack propagation and measure the crack velocity in the radial direction of the tubes. Pre-cracks were produced at the outer surfaces of the tubes. Hydrogen contents of the tubes were from 90 ppm to 130 ppm and test temperatures were from 225 Degree-Sign C to 300 Degree-Sign C. The crack velocity followed the Arrhenius law at temperatures lower than about 270 Degree-Sign C with apparent activation energy of about 49 kJ/mol. The upper temperature limit for DHC, above which DHC did not occur, was about 280 Degree-Sign C. The threshold stress intensity factor for the initiation of the crack propagation, K{sub IH}, was from about 4 MPa m{sup 1/2} to 6 MPa m{sup 1/2}, almost independent of temperature. An increase in 0.2% offset yield stress of the material accelerated the crack velocity and slightly decreased K{sub IH}. Detailed observations of crack tip movement showed that cracks propagated in an intermittent fashion and the propagation gradually approached the steady state as the crack depth increased. The SEM observations also showed that hydrides were formed at a crack tip and a number of micro-cracks were found in the hydrides. It was presumed from these observations that the repetition of precipitation and fracture of hydrides at the crack tip would be

  9. 30 CFR 202.353 - Measurement standards for reporting and paying royalties and direct use fees.

    Science.gov (United States)

    2010-07-01

    ... royalties and direct use fees. 202.353 Section 202.353 Mineral Resources MINERALS MANAGEMENT SERVICE... standards for reporting and paying royalties and direct use fees. (a) For geothermal resources used to... a royalty or direct use fee is due on Form MMS-2014 in: (1) Millions of Btu to the nearest whole...

  10. Investigating summer flow paths in a Dutch agricultural field using high frequency direct measurements

    Science.gov (United States)

    Delsman, J. R.; Waterloo, M. J.; Groen, M. M. A.; Groen, J.; Stuyfzand, P. J.

    2014-11-01

    The search for management strategies to cope with projected water scarcity and water quality deterioration calls for a better understanding of the complex interaction between groundwater and surface water in agricultural catchments. We separately measured flow routes to tile drains and an agricultural ditch in a deep polder in the coastal region of the Netherlands, characterized by exfiltration of brackish regional groundwater flow and intake of diverted river water for irrigation and water quality improvement purposes. We simultaneously measured discharge, electrical conductivity and temperature of these separate flow routes at hourly frequencies, disclosing the complex and time-varying patterns and origins of tile drain and ditch exfiltration. Tile drainage could be characterized as a shallow flow system, showing a non-linear response to groundwater level changes. Tile drainage was fed primarily by meteoric water, but still transported the majority (80%) of groundwater-derived salt to surface water. In contrast, deep brackish groundwater exfiltrating directly in the ditch responded linearly to groundwater level variations and is part of a regional groundwater flow system. We could explain the observed salinity of exfiltrating drain and ditch water from the interaction between the fast-responding pressure distribution in the subsurface that determined groundwater flow paths (wave celerity), and the slow-responding groundwater salinity distribution (water velocity). We found water demand for maintaining water levels and diluting salinity through flushing to greatly exceed the actual sprinkling demand. Counterintuitively, flushing demand was found to be largest during precipitation events, suggesting the possibility of water savings by operational flushing control.

  11. Direct measurement of the precursors of adrenocorticotropin in human plasma by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Crosby, S.R.; Stewart, M.F.; Ratcliffe, J.G.; White, A.

    1988-01-01

    An immunoradiometric assay (IRMA) for the direct measurement of the precursors of ACTH in unextracted human plasma has been developed and evaluated clinically in normal subjects and patients with disorders of the hypothalamic-pituitary-adrenal axis. The IRMA is based on an iodinated monoclonal antibody to ACTH and a monoclonal antibody to gamma MSH coupled to Sephacryl S300. The assay detects only peptides containing both epitopes, i.e. POMC (31K) and pro-ACTH (22K). The reference standard was partially purified POMC from culture medium of human corticotroph adenoma cells. The detection limit (greater than +2.5SD of the 0 standard) was 2.0 pmol/L and the within-assay coefficient of variation was less than 10% between 29 and 2600 pmol/L. Plasma concentrations of ACTH precursor peptides in 11 normal subjects sampled at 0930 h ranged from 5-34 pmol/L. The concentrations in the patient groups studied were: 260-2300 pmol/L in 5 patients with the ectopic ACTH syndrome associated with small cell lung cancer, less than 2.0-104 pmol/L in 10 patients with pituitary-dependent Cushing's disease, 23 pmol/L in a patient with Nelson's syndrome, and 3.0-230 pmol/L in 5 patients with Addison's disease. We conclude that this IRMA offers a simple and reliable method for measuring ACTH precursors in unextracted plasma. The proportionately greater elevation of ACTH precursors compared to ACTH in patients with the ectopic ACTH syndrome associated with small cell lung cancer but not in pituitary-dependent Cushing's syndrome, suggests that this assay may be clinically useful

  12. Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

    International Nuclear Information System (INIS)

    Sun, Lue; Mizuno, Yusuke; Goto, Takahisa; Iwamoto, Mari; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi

    2014-01-01

    Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose-area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. (author)

  13. A gateway to new physics: direct measurement of the top Yukawa coupling to the Higgs boson

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00405244; Wermes, Norbert

    The top quark has the largest Yukawa coupling in the Standard Model, is the main contribution to the Higgs mass $m_H$ corrections and defines the evolution of the Higgs effective potential with the energy, together with $m_H$. It can be directly measured through the associated production process $pp \\to t\\bar{t}H$. Two searches for this process are described in this thesis, using data collected with the ATLAS detector at the Large Hadron Collider. The fully hadronic analysis is performed with data corresponding to an integrated luminosity of $20.3\\,\\text{fb}^{-1}$ at a centre-of-mass energy of $\\sqrt{s}=8\\,\\text{TeV}$ and uses a boosted decision tree algorithm to discriminate between signal and background: the dominant multijet background is estimated using a data-driven method. An upper limit of $6.4$ ($5.4$) times the Standard Model cross section is observed (expected) at 95% confidence level and a best-fit value of $1.6 \\pm 2.6$ for the signal strength $\\mu_{t\\bar{t}H}=\\sigma_{t\\bar{t}H}^\\text{obs}/\\sigma...

  14. Measurement of photon production in the very forward direction in deep-inelastic scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, F.D. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania); Bucharest Univ. (Romania). Faculty of Physics; Alexa, C. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania); Andreev, V. [Lebedev Physical Institute, Moscow (RU)] (and others)

    2011-06-15

    The production of photons at very small angles with respect to the proton beam direction is studied in deep-inelastic positron-proton scattering at HERA. The data are taken with the H1 detector in the years 2006 and 2007 and correspond to an integrated luminosity of 126 pb{sup -1}. The analysis covers the range of negative four momentum transfer squared at the positron vertex 6measured for the most energetic photon with pseudorapidity {eta}>7.9 as a function of its transverse momentum p{sub T}{sup lead} and longitudinal momentum fraction of the incoming proton x{sub L}{sup lead}. In addition, the cross sections are studied as a function of the sum of the longitudinal momentum fraction x{sub L}{sup sum} of all photons in the pseudorapidity range {eta}>7.9. The cross sections are normalised to the inclusive deep-inelastic scattering cross section and compared to the predictions of models of deep-inelastic scattering and models of the hadronic interactions of high energy cosmic rays. (orig.)

  15. Direct measurement of local oxygen concentration in the bone marrow of live animals

    Science.gov (United States)

    Spencer, Joel A.; Ferraro, Francesca; Roussakis, Emmanuel; Klein, Alyssa; Wu, Juwell; Runnels, Judith M.; Zaher, Walid; Mortensen, Luke J.; Alt, Clemens; Turcotte, Raphaël; Yusuf, Rushdia; Côté, Daniel; Vinogradov, Sergei A.; Scadden, David T.; Lin, Charles P.

    2014-04-01

    Characterization of how the microenvironment, or niche, regulates stem cell activity is central to understanding stem cell biology and to developing strategies for the therapeutic manipulation of stem cells. Low oxygen tension (hypoxia) is commonly thought to be a shared niche characteristic in maintaining quiescence in multiple stem cell types. However, support for the existence of a hypoxic niche has largely come from indirect evidence such as proteomic analysis, expression of hypoxia inducible factor-1α (Hif-1α) and related genes, and staining with surrogate hypoxic markers (for example, pimonidazole). Here we perform direct in vivo measurements of local oxygen tension (pO2) in the bone marrow of live mice. Using two-photon phosphorescence lifetime microscopy, we determined the absolute pO2 of the bone marrow to be quite low (hypoxic as it is perfused with small arteries that are often positive for the marker nestin. These pO2 values change markedly after radiation and chemotherapy, pointing to the role of stress in altering the stem cell metabolic microenvironment.

  16. Direct Measurement of Surface Dissolution Rates in Potential Nuclear Waste Forms: The Example of Pyrochlore.

    Science.gov (United States)

    Fischer, Cornelius; Finkeldei, Sarah; Brandt, Felix; Bosbach, Dirk; Luttge, Andreas

    2015-08-19

    The long-term stability of ceramic materials that are considered as potential nuclear waste forms is governed by heterogeneous surface reactivity. Thus, instead of a mean rate, the identification of one or more dominant contributors to the overall dissolution rate is the key to predict the stability of waste forms quantitatively. Direct surface measurements by vertical scanning interferometry (VSI) and their analysis via material flux maps and resulting dissolution rate spectra provide data about dominant rate contributors and their variability over time. Using pyrochlore (Nd2Zr2O7) pellet dissolution under acidic conditions as an example, we demonstrate the identification and quantification of dissolution rate contributors, based on VSI data and rate spectrum analysis. Heterogeneous surface alteration of pyrochlore varies by a factor of about 5 and additional material loss by chemo-mechanical grain pull-out within the uppermost grain layer. We identified four different rate contributors that are responsible for the observed dissolution rate range of single grains. Our new concept offers the opportunity to increase our mechanistic understanding and to predict quantitatively the alteration of ceramic waste forms.

  17. Melt-Pool Temperature and Size Measurement During Direct Laser Sintering

    Energy Technology Data Exchange (ETDEWEB)

    List, III, Frederick Alyious [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dinwiddie, Ralph Barton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Carver, Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gockel, Joy E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    Additive manufacturing has demonstrated the ability to fabricate complex geometries and components not possible with conventional casting and machining. In many cases, industry has demonstrated the ability to fabricate complex geometries with improved efficiency and performance. However, qualification and certification of processes is challenging, leaving companies to focus on certification of material though design allowable based approaches. This significantly reduces the business case for additive manufacturing. Therefore, real time monitoring of the melt pool can be used to detect the development of flaws, such as porosity or un-sintered powder and aid in the certification process. Characteristics of the melt pool in the Direct Laser Sintering (DLS) process is also of great interest to modelers who are developing simulation models needed to improve and perfect the DLS process. Such models could provide a means to rapidly develop the optimum processing parameters for new alloy powders and optimize processing parameters for specific part geometries. Stratonics’ ThermaViz system will be integrated with the Renishaw DLS system in order to demonstrate its ability to measure melt pool size, shape and temperature. These results will be compared with data from an existing IR camera to determine the best approach for the determination of these critical parameters.

  18. Measurement of photon production in the very forward direction in deep-inelastic scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, F.D.; Alexa, C.; Rotaru, M.; Stoicea, G. [National Inst. for Physics and Nuclear Engineering, Bucharest (Romania); Andreev, V.; Belousov, A.; Eliseev, A.; Fomenko, A.; Gogitidze, N.; Lebedev, A.; Malinovski, E.; Rusakov, S.; Shtarkov, L.N.; Soloviev, Y.; Vazdik, Y. [Lebedev Physical Inst., Moscow (Russian Federation); Backovic, S.; Dubak, A.; Lastovicka-Medin, G.; Picuric, I.; Raicevic, N. [Univ. of Montenegro, Podgorica (ME); Baghdasaryan, A.; Baghdasaryan, S.; Zohrabyan, H. [Yerevan Physics Inst. (Armenia); Barrelet, E. [Univ. Pierre et Marie Curie Paris 6, LPNHE, Paris (France); Univ. Denis Diderot Paris 7, CNRS/IN2P3, Paris (France); Bartel, W.; Belov, P.; Brandt, G.; Brinkmann, M.; Britzger, D.; Campbell, A.J.; Eckerlin, G.; Elsen, E.; Felst, R.; Fischer, D.J.; Fleischer, M.; Gayler, J.; Ghazaryan, S.; Glazov, A.; Gouzevitch, M.; Grebenyuk, A.; Grell, B.R.; Habib, S.; Haidt, D.; Helebrant, C.; Kleinwort, C.; Kogler, R.; Kraemer, M.; Levonian, S.; Lipka, K.; List, J.; Meyer, A.B.; Meyer, J.; Niebuhr, C.; Nowak, K.; Olsson, J.E.; Pahl, P.; Panagoulias, I.; Papadopoulou, T.; Petrukhin, A.; Piec, S.; Pitzl, D.; Schmitt, S.; Sefkow, F.; South, D.; Steder, M.; Wuensch, E. [DESY, Hamburg (Germany); Begzsuren, K.; Ravdandorj, T.; Tseepeldorj, B. [Inst. of Physics and Technology of the Mongolian Academy of Sciences, Ulaanbaatar (Mongolia); Bizot, J.C.; Brisson, V.; Delcourt, B.; Jacquet, M.; Pascaud, C.; Tran, T.H.; Zhang, Z.; Zomer, F. [Univ. Paris-Sud, CNRS/IN2P3, LAL, Orsay (France); Boudry, V.; Moreau, F.; Specka, A. [Ecole Polytechnique, CNRS/IN2P3, LLR, Palaiseau (France); Bozovic-Jelisavcic, I.; Mudrinic, M.; Pandurovic, M.; Smiljanic, I. [Univ. of Belgrade, Vinca Institute of Nuclear Sciences, Belgrade (RS); Bracinik, J.; Kenyon, I.R.; Newman, P.R.; Thompson, P.D. [Univ. of Birmingham (United Kingdom); Bruncko, D.; Cerny, V.; Ferencei, J. [Slovak Academy of Sciences, Inst. of Experimental Physics, Kosice (Slovakia)] [and others

    2011-10-15

    The production of photons at very small angles with respect to the proton beam direction is studied in deep-inelastic positron-proton scattering at HERA. The data are taken with the H1 detector in the years 2006 and 2007 and correspond to an integrated luminosity of 126 pb{sup -1}. The analysis covers the range of negative four momentum transfer squared at the positron vertex 6measured for the most energetic photon with pseudorapidity {eta}>7.9 as a function of its transverse momentum p{sub T}{sup lead} and longitudinal momentum fraction of the incoming proton x{sub L}{sup lead}. In addition, the cross sections are studied as a function of the sum of the longitudinal momentum fraction x{sub L}{sup sum} of all photons in the pseudorapidity range {eta}>7.9. The cross sections are normalised to the inclusive deep-inelastic scattering cross section and compared to the predictions of models of deep-inelastic scattering and models of the hadronic interactions of high energy cosmic rays. (orig.)

  19. Direct assessment as a measure of institutional effectiveness in a dental hygiene distance education program.

    Science.gov (United States)

    Olmsted, Jodi L

    2014-10-01

    This ten-year, longitudinal examination of a dental hygiene distance education (DE) program considered student performance on standard benchmark assessments as direct measures of institutional effectiveness. The aim of the study was to determine if students face-to-face in a classroom with an instructor performed differently from their counterparts in a DE program, taking courses through the alternative delivery system of synchronous interactive television (ITV). This study used students' grade point averages and National Board Dental Hygiene Examination scores to assess the impact of ITV on student learning, filling a crucial gap in current evidence. The study's research population consisted of 189 students who graduated from one dental hygiene program between 1997 and 2006. One hundred percent of the institution's data files for these students were used: 117 students were face-to-face with the instructor, and seventy-two received instruction through the ITV system. The results showed that, from a year-by-year perspective, no statistically significant performance differences were apparent between the two student groups when t-tests were used for data analysis. The DE system examined was considered effective for delivering education if similar performance outcomes were the evaluation criteria used for assessment.

  20. Serum and urinary oestrone sulphate in pregnancy and delivery measured by a direct radioimmunoassay

    International Nuclear Information System (INIS)

    Honjo, Hideo; Kitawaki, Jo; Itoh, Masafumi; Yasuda, Jinsuke; Yamamoto, Takara; Yamamoto, Takao; Okada, Hiroji; Ohkubo, Tadashi; Nambara, Toshio

    1986-01-01

    Serum and urinary levels of oestrone sulphate in pregnancy and delivery were measured by a direct radioimmunoassay without hydrolysis. the serum and urinary oestrone sulphate increased as pregnancy progressed. the mean level of serum oestrone sulphate increased to the highest peak of 494 pmol/ml at the 35th gestational week and then decreased. The mean level of urinary oestrone sulphate increased to the highest peak of 1.28 μmol/l at the 34th gestational week and the decreased. At vaginal deliveries, the mean level of maternal peripheral serum oestrone sulphate increased hourly at as high a level as 979 pmol/ml. The mean serum level of oestrone sulphate was 204 pmol/ml in the umbilical artery and 145 pmol/ml in the umbilical vein. At Caesarean section, on the other hand, the maternal peripheral serum level of oestrone sulphate averaged 362 pmol/ml. The mean serum levels of oestrone sulphate wre 90.7 pmol/ml and 171 pmol/ml in the umbilical artery and umbilical vein, respectively. These results suggest a maternal origin of oestrone sulphate in pregnancy, with fluctuations in the levels being of interest in relation to labour pain. (author)

  1. Direct Measurements of Leaf Level CH4 and CO2 Exchange in a Boreal Forest

    Science.gov (United States)

    Crill, P.; Lindroth, A.; Vestin, P.; Båth, A.

    2008-12-01

    Reports of aerobic CH4 sources from leaves and litter of a variety of forests and plant functional types have added a potential mystery to our understanding of CH4 dynamics especially if these sources contribute enough to have a significant impact on the global budget. We have made direct measurements of leaf level CH4 and CO2 exchange using a quartz branch cuvette in a boreal forest in Norunda, Sweden since August of this year. The cuvette was temperature controlled and was designed to close for 5 minutes every 30 minutes. Air was circulated to a Los Gatos CH4/CO2 infrared absorption laser spectrometer. Air and cuvette temperatures, PAR and UV radiation (Kipp and Zonen, CUV4; spectral range 300-380 nm) were measured at the branch chamber. The study was made in the Norunda 100 years old stand consisting of a mixture of Scots pine (Pinus sylvestris L.) , Birch (Betula sp.) and Norway spruce (Picea abies (L.) Karst.). The cuvette was moved between trees at roughly 5 day intervals. A null empty cuvette period was included in the rotation. The initial data show the expected CO2 uptake correlated with incident PAR and low rates of emission at night. However, there was no clear pattern of emissions detectable in the CH4. We estimate that we should be able to resolve a change of 0.5 ppbv CH4 min- 1 with our analytical setup. Both the daytime (1000-1600) and nighttime (2200-0400) averages were less than our detection. Even on very sunny days with high PAR and UV flux values, no consistent pattern was detectable. The lack of a distinct signal may be due to the fact that the past month has been very rainy, it is late in the growth season at these latitudes and sun angles are increasing quickly. The trees were at the northern edge of a clearing and we were also measuring mid height (2-3 m) leaves and branches of young trees. The branch cuvette design can also be optimized to improve its sensitivity.

  2. Direct Measurements of Smartphone Screen-Time: Relationships with Demographics and Sleep.

    Science.gov (United States)

    Christensen, Matthew A; Bettencourt, Laura; Kaye, Leanne; Moturu, Sai T; Nguyen, Kaylin T; Olgin, Jeffrey E; Pletcher, Mark J; Marcus, Gregory M

    2016-01-01

    Smartphones are increasingly integrated into everyday life, but frequency of use has not yet been objectively measured and compared to demographics, health information, and in particular, sleep quality. The aim of this study was to characterize smartphone use by measuring screen-time directly, determine factors that are associated with increased screen-time, and to test the hypothesis that increased screen-time is associated with poor sleep. We performed a cross-sectional analysis in a subset of 653 participants enrolled in the Health eHeart Study, an internet-based longitudinal cohort study open to any interested adult (≥ 18 years). Smartphone screen-time (the number of minutes in each hour the screen was on) was measured continuously via smartphone application. For each participant, total and average screen-time were computed over 30-day windows. Average screen-time specifically during self-reported bedtime hours and sleeping period was also computed. Demographics, medical information, and sleep habits (Pittsburgh Sleep Quality Index-PSQI) were obtained by survey. Linear regression was used to obtain effect estimates. Total screen-time over 30 days was a median 38.4 hours (IQR 21.4 to 61.3) and average screen-time over 30 days was a median 3.7 minutes per hour (IQR 2.2 to 5.5). Younger age, self-reported race/ethnicity of Black and "Other" were associated with longer average screen-time after adjustment for potential confounders. Longer average screen-time was associated with shorter sleep duration and worse sleep-efficiency. Longer average screen-times during bedtime and the sleeping period were associated with poor sleep quality, decreased sleep efficiency, and longer sleep onset latency. These findings on actual smartphone screen-time build upon prior work based on self-report and confirm that adults spend a substantial amount of time using their smartphones. Screen-time differs across age and race, but is similar across socio-economic strata suggesting that

  3. Direct Measurements of Smartphone Screen-Time: Relationships with Demographics and Sleep.

    Directory of Open Access Journals (Sweden)

    Matthew A Christensen

    Full Text Available Smartphones are increasingly integrated into everyday life, but frequency of use has not yet been objectively measured and compared to demographics, health information, and in particular, sleep quality.The aim of this study was to characterize smartphone use by measuring screen-time directly, determine factors that are associated with increased screen-time, and to test the hypothesis that increased screen-time is associated with poor sleep.We performed a cross-sectional analysis in a subset of 653 participants enrolled in the Health eHeart Study, an internet-based longitudinal cohort study open to any interested adult (≥ 18 years. Smartphone screen-time (the number of minutes in each hour the screen was on was measured continuously via smartphone application. For each participant, total and average screen-time were computed over 30-day windows. Average screen-time specifically during self-reported bedtime hours and sleeping period was also computed. Demographics, medical information, and sleep habits (Pittsburgh Sleep Quality Index-PSQI were obtained by survey. Linear regression was used to obtain effect estimates.Total screen-time over 30 days was a median 38.4 hours (IQR 21.4 to 61.3 and average screen-time over 30 days was a median 3.7 minutes per hour (IQR 2.2 to 5.5. Younger age, self-reported race/ethnicity of Black and "Other" were associated with longer average screen-time after adjustment for potential confounders. Longer average screen-time was associated with shorter sleep duration and worse sleep-efficiency. Longer average screen-times during bedtime and the sleeping period were associated with poor sleep quality, decreased sleep efficiency, and longer sleep onset latency.These findings on actual smartphone screen-time build upon prior work based on self-report and confirm that adults spend a substantial amount of time using their smartphones. Screen-time differs across age and race, but is similar across socio-economic strata

  4. Ten years statistics of wind direction and wind velocity measurements performed at the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Becker, M.; Dilger, H.

    1979-06-01

    The measurements of wind direction and wind velocity performed at 60 m and 200 m height were evaluated for one year each and frequency distributions of the measured values were established. The velocity was divided into 1 m/s steps and the direction into 10 0 sectors. The frequency distribution of the wind direction reveals three maxima located in the southwest, northeast and north, respectively. The maximum of the frequency distribution of the wind velocity occurs between 4 and 5 m/s at 200 m height and between 3 and 4 m/s at 60 m height. (orig.) [de

  5. VALIDATION OF MITRAL VALVE ANNULUS DIMENSIONS MEASURED BY 2D TRANS-THORACIC ECHOCARDIOGRAPHY WITH GOLD STANDARD DIRECT INTRA-OPERATIVE MEASUREMENT

    OpenAIRE

    Praveen; Yadav; Ankur; Saket; Kaushal

    2014-01-01

    CONTEXT: Precise estimation of Mitral valve annulus dimensions preoperatively through Echocardiography is of paramount importance in replacement/repair surgeries. However a frequent disagreement was experienced between anticipated size of prosthetic valve based on echocardiography and actual valve size. This fact encouraged the authors to validate the measurements through echocardiography with gold-standard direct intra operative measurement. AIM: To compare the mitral val...

  6. Comparison of direct inter-filament resistance measurement on Nb3Sn strands between University of Twente and ENEA

    NARCIS (Netherlands)

    Zhou, Chao; Dhalle, Marc M.J.; Nijhuis, Arend; Breschi, M.; Spina, T.; Della Corte, A.; Corato, V.

    2013-01-01

    Experimental results of interfilament resistance measurements obtained with different facilities are compared. Two internal tin Nb3Sn strand types are tested at the University of Twente (UT) and ENEA Frascati. The direct interfilament resistance is measured with a standard four-point voltage-current

  7. Impact of hepatitis C virus genotype-4 eradication following direct acting antivirals on liver stiffness measurement

    Directory of Open Access Journals (Sweden)

    Tag-Adeen M

    2017-10-01

    Full Text Available Mohammed Tag-Adeen,1,2 Ahlam Mohamed Sabra,1 Yuko Akazawa,2 Ken Ohnita,2 Kazuhiko Nakao2 1Department of Internal Medicine, Qena School of Medicine, South Valley University, Qena, Egypt; 2Department of Gastroenterology and Hepatology, Nagasaki School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan Background: Liver fibrosis is the most important prognostic factor in chronic hepatitis C virus (HCV patients, and Egypt shows the highest worldwide HCV prevalence with genotype-4 predominance. The aim of this study was to investigate the degree of liver stiffness measurement (LSM improvement after successful HCV eradication.Patients and methods: The study included 84 chronic HCV Egyptian patients, and was conducted at Qena University Hospital from November 1, 2015 till October 31, 2016. LSM was obtained by FibroScan® before starting direct acting antiviral (DAA treatment and after achieving sustained virologic response-24 (SVR-24. Based on baseline LSM, patients were stratified into F0–F1, F2, F3 and F4 groups (METAVIR. LSM and laboratory data after achieving SVR-24 was compared with that before starting therapy in each fibrosis group (F0-F4, p-value <0.05 was statistically significant.Results: Following DAA treatment, 80 patients achieved SVR-24; of these, 50 were males (62.5%, mean age: 54.2±7.6 years, and mean body mass index: 28.6±2.2 kg/m2. Mean baseline LSM dropped from 15.6±10.8 to 12.1±8.7 kPa post-SVR; the maximum change of −5.8 occurred in F4 versus −2.79, −1.28 and +0.08 in F3, F2 and F0–F1 respectively (p<0.0001. At baseline, 41 patients were in the F4 group; only 16 (39% regressed to non-cirrhotic range (<12.5 kPa, while 25 (61% were still cirrhotic despite achieving SVR-24 (p<0.0001. Patients who achieved LSM improvement (n=64 have had significantly higher baseline aspartate transferase (AST and alanine transaminase (ALT. Also, those patients showed significant improvement in AST, AST/platelets ratio index

  8. Direct measurement of human plasma corticotropin-releasing hormone by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Linton, E.A.; McLean, C.; Nieuwenhuyzen Kruseman, A.C.; Tilders, F.J.; Van der Veen, E.A.; Lowry, P.J.

    1987-01-01

    A ''two-site'' immunoradiometric assay (IRMA) which allows the direct estimation of human CRH (hCRH) in plasma is described. Using this IRMA, basal levels of CRH in normal subjects ranged from 2-28 pg/mL [mean, 15 +/- 7 (+/- SD) pg/mL; n = 58]. Values in men and women were similar. Plasma CRH values within this range were also found in patients with Cushing's syndrome, Addison's disease, and Nelson's syndrome, with no correlation between plasma CRH and ACTH levels in these patients. Elevated plasma CRH levels were found in pregnant women near term [1462 +/- 752 (+/- SD) pg/mL; n = 55], and the dilution curve of this CRH-like immunoreactivity paralleled the IRMA standard curve. After its immunoadsorption from maternal plasma, this CRH-like material eluted on reverse phase high performance liquid chromatography with a retention time identical to that of synthetic CRH and had equipotent bioactivity with the synthetic peptide in the perfused anterior pituitary cell bioassay. Circulating CRH was not detected in Wistar rats, even after adrenalectomy and subsequent ether stress. Synthetic hCRH was degraded by fresh human plasma relatively slowly; 65% of added CRH remained after 1 h of incubation at 37 C. Degradation was inhibited by heat treatment (54 C; 1 h), cold treatment (4 C; 4 h), or freezing and thawing. Loss of synthetic rat CRH occurred more rapidly when fresh rat plasma was used; only 20% of added CRH remained under the same conditions. The inability to measure CRH in peripheral rat plasma may be due to the presence of active CRH-degrading enzymes which fragment the CRH molecule into forms not recognized by the CRH IRMA

  9. A Management State of POPs (Persistent Organic Pollutants) and the Measuring Direction - Centered By-Products

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Gyu; Lee, Hee Seon [Korea Environment Institute, Seoul (Korea)

    2000-12-01

    The chemical materials, DDT and Dioxin, threaten the human health and take the high toxicity on ecosystem and a living thing. Because the chemical materials remain in environment for a long time due to a slow natural decomposition, they are biologically concentrated through the food cycle in ecosystem and have a characteristic to move a long distance. Owing to such toxicity and the characteristics of chemical materials, the world organization named them as Persistent Organic Pollutants (POPs) and has been actively progressing the international movement to strictly restrict them since the middle of 1990s. POPs regulation agreement, which is on progress centered in UNEP, is facing to the conclusion of the agreement of 2001 year. An agricultural chemical of organic chlorine among 12 POPs indicated by UNEP has been already prohibited in the domestic use and manufacturing or not registered, so the basic research, including search and monitoring if POPs remain or not, is required afterward. Because Dioxin, Puran, Hexachlorobenzene (HCB) among POPs, which are produced as by-products from all kinds of industrial processes, are not raw materials dislike other POPs, their use and manufacturing cannot be only prohibited by the related law but also they have few substitutes. Therefore, they should be applied by the different regulation from the existing toxic chemicals in order to manage the toxicity of the materials. However, the regulation on by-products among POPs is just in the beginning stage, and even the producing source has not been yet confirmed. This study suggests the necessity of the management on Dioxin, Puran, HCB, by-products among POPs, and presents the measuring direction with grasping the domestic and foreign trend of the regulation on the materials. 70 refs., 2 figs., 56 tabs.

  10. Direct measurement of osmotic pressure of glycosaminoglycan solutions by membrane osmometry at room temperature.

    Science.gov (United States)

    Chahine, Nadeen O; Chen, Faye H; Hung, Clark T; Ateshian, Gerard A

    2005-09-01

    Articular cartilage is a hydrated soft tissue composed of negatively charged proteoglycans fixed within a collagen matrix. This charge gradient causes the tissue to imbibe water and swell, creating a net osmotic pressure that enhances the tissue's ability to bear load. In this study we designed and utilized an apparatus for directly measuring the osmotic pressure of chondroitin sulfate, the primary glycosaminoglycan found in articular cartilage, in solution with varying bathing ionic strength (0.015 M, 0.15 M, 0.5 M, 1 M, and 2 M NaCl) at room temperature. The osmotic pressure (pi) was found to increase nonlinearly with increasing chondroitin sulfate concentration and decreasing NaCl ionic bath environment. Above 1 M NaCl, pi changes negligibly with further increases in salt concentration, suggesting that Donnan osmotic pressure is negligible above this threshold, and the resulting pressure is attributed to configurational entropy. Results of the current study were also used to estimate the contribution of osmotic pressure to the stiffness of cartilage based on theoretical and experimental considerations. Our findings indicate that the osmotic pressure resulting from configurational entropy is much smaller in cartilage (based on an earlier study on bovine articular cartilage) than in free solution. The rate of change of osmotic pressure with compressive strain is found to contribute approximately one-third of the compressive modulus (H(A)(eff)) of cartilage (Pi approximately H(A)(eff)/3), with the balance contributed by the intrinsic structural modulus of the solid matrix (i.e., H(A) approximately 2H(A)(eff)/3). A strong dependence of this intrinsic modulus on salt concentration was found; therefore, it appears that proteoglycans contribute structurally to the magnitude of H(A), in a manner independent of osmotic pressure.

  11. Measurement of the optical density of packable composites: comparison between direct and indirect digital systems

    Directory of Open Access Journals (Sweden)

    Graziottin Luiz Felipe Rodrigues

    2002-01-01

    Full Text Available The aim of this study was to measure the optical density of four packable composite resins with widths of 1, 2, 3 and 4 mm, by means of Digora® (direct and DentScan DentView® (indirect digital imaging systems, in order to compare both methods. Twenty acrylic plates, with the proposed thicknesses, were used, each one containing a sample of each resin. Each acrylic plate was radiographed three times, under a standardized technique. For the Digora® system, an optical plate was used under each resin sample, and, for the DentScan DentView® system, occlusal films were employed, totalizing 60 exposures for each system. Optical plates and films were scanned and three consecutive optical readouts were carried out, totalizing 1,440 readouts. The results were submitted to statistical analysis and revealed that the average optical density of the four resins always increased as thickness increased. Regarding the comparisons between the composite resins, in both analysis the resin with the greater optical density was SurefilTM followed by ProdigyTM Condensable, AlertTM and Solitaire®. The correlations between the results of Digora® and DentScan DentView® were significant for the different thicknesses and materials. The observed tendency is that as the values obtained with the Digora® system increase, so do the values obtained with DentScan DentView®. While thickness increased, the values of optical density in both Digora® and DentScan DentView® tended to approach each other. The Digora® system presented smaller amplitude between the results obtained in adjacent thicknesses.

  12. Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry.

    Directory of Open Access Journals (Sweden)

    Laura M Langan

    Full Text Available Advanced in vitro culture from tissues of different origin includes three-dimensional (3D organoid micro structures that may mimic conditions in vivo. One example of simple 3D culture is spheroids; ball shaped structures typically used as liver and tumour models. Oxygen is critically important in physiological processes, but is difficult to quantify in 3D culture: and the question arises, how small does a spheroid have to be to have minimal micro-environment formation? This question is of particular importance in the growing field of 3D based models for toxicological assessment. Here, we describe a simple non-invasive approach modified for the quantitative measurement and subsequent evaluation of oxygen gradients in spheroids developed from a non-malignant fish cell line (i.e. RTG-2 cells using Electron Paramagnetic Resonance (EPR oximetry. Sonication of the paramagnetic probe Lithium phthalocyanine (LiPc allows for incorporation of probe particulates into spheroid during its formation. Spectra signal strength after incorporation of probe into spheroid indicated that a volume of 20 μl of probe (stock solution: 0.10 mg/mL is sufficient to provide a strong spectra across a range of spheroid sizes. The addition of non-toxic probes (that do not produce or consume oxygen report on oxygen diffusion throughout the spheroid as a function of size. We provide evidence supporting the use of this model over a range of initial cell seeding densities and spheroid sizes with the production of oxygen distribution as a function of these parameters. In our spheroid model, lower cell seeding densities (∼2,500 cells/spheroid and absolute size (118±32 μm allow control of factors such as pre-existing stresses (e.g. ∼ 2% normoxic/hypoxic interface for more accurate measurement of treatment response. The applied methodology provides an elegant, widely applicable approach to directly characterize spheroid (and other organoid cultures in biomedical and

  13. Measuring Self-Directed Learning: A Diagnostic Tool for Adult Learners

    Science.gov (United States)

    Khiat, Henry

    2015-01-01

    Self-directed learning is an important form of adult learning (Caffarella, 1993; Knowles, 1975; Knowles, Holton & Swanson, 2005; Merriam, 2001; Merriam & Caffarella, 1999). The strategies of self-directed learning allow adult learners to cope better with their studies while fulfilling family, work and other commitments. This study…

  14. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  15. Improved pointing information for SCIAMACHY from in-flight measurements of the viewing directions towards sun and moon

    Science.gov (United States)

    Bramstedt, Klaus; Stone, Thomas C.; Gottwald, Manfred; Noël, Stefan; Bovensmann, Heinrich; Burrows, John P.

    2017-07-01

    The SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) on Envisat (2002-2012) performed nadir, limb, solar/lunar occultation and various monitoring measurements. The pointing information of the instrument is determined by the attitude information of the Envisat platform with its star trackers together with the encoder readouts of both the azimuth and the elevation scanner of SCIAMACHY. In this work, we present additional sources of attitude information from the SCIAMACHY measurements itself. The basic principle is the same as used by the star tracker: we measure the viewing direction towards celestial objects, i.e. sun and moon, to detect possible mispointings. In sun over limb port observations, we utilise the vertical scans over the solar disk. In horizontal direction, SCIAMACHY's sun follower device (SFD) is used to adjust the viewing direction. Moon over limb port measurements use for both the vertical and the horizontal direction the adjustment by the SFD. The viewing direction is steered towards the intensity centroid of the illuminated part of the lunar disk. We use reference images from the USGS Robotic Lunar Observatory (ROLO) to take into account the inhomogeneous surface and the variations by lunar libration and phase to parameterise the location of the intensity centroid from the observation geometry. Solar observations through SCIAMACHY's so-called sub-solar port (with a viewing direction closely to zenith) also use the SFD in the vertical direction. In the horizontal direction the geometry of the port defines the viewing direction. Using these three type of measurements, we fit improved mispointing parameters by minimising the pointing offsets in elevation and azimuth. The geolocation of all retrieved products will benefit from this; the tangent heights are especially improved. The altitudes assigned to SCIAMACHY's solar occultation measurements are changed in the range of -130 to -330 m, the lunar occultation

  16. Improved pointing information for SCIAMACHY from in-flight measurements of the viewing directions towards sun and moon

    Directory of Open Access Journals (Sweden)

    K. Bramstedt

    2017-07-01

    Full Text Available The SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY on Envisat (2002–2012 performed nadir, limb, solar/lunar occultation and various monitoring measurements. The pointing information of the instrument is determined by the attitude information of the Envisat platform with its star trackers together with the encoder readouts of both the azimuth and the elevation scanner of SCIAMACHY. In this work, we present additional sources of attitude information from the SCIAMACHY measurements itself. The basic principle is the same as used by the star tracker: we measure the viewing direction towards celestial objects, i.e. sun and moon, to detect possible mispointings. In sun over limb port observations, we utilise the vertical scans over the solar disk. In horizontal direction, SCIAMACHY's sun follower device (SFD is used to adjust the viewing direction. Moon over limb port measurements use for both the vertical and the horizontal direction the adjustment by the SFD. The viewing direction is steered towards the intensity centroid of the illuminated part of the lunar disk. We use reference images from the USGS Robotic Lunar Observatory (ROLO to take into account the inhomogeneous surface and the variations by lunar libration and phase to parameterise the location of the intensity centroid from the observation geometry. Solar observations through SCIAMACHY's so-called sub-solar port (with a viewing direction closely to zenith also use the SFD in the vertical direction. In the horizontal direction the geometry of the port defines the viewing direction. Using these three type of measurements, we fit improved mispointing parameters by minimising the pointing offsets in elevation and azimuth. The geolocation of all retrieved products will benefit from this; the tangent heights are especially improved. The altitudes assigned to SCIAMACHY's solar occultation measurements are changed in the range of −130 to −330 m, the lunar

  17. Direct measurements of adsorption heats of hydrogen on nano-porous carbons

    International Nuclear Information System (INIS)

    Akihiko Matsumoto; Kazumasa Yamamoto; Tomoyuki Miyata

    2005-01-01

    Since a exciting report of hydrogen storage in single-walled carbon nano-tubes by Dillon and his colleagues, nano-porous carbon materials, such as carbon nano-tubes, carbon nano-horns and micro-porous activated carbon, have attracted considerable attention as hydrogen storage materials. Adsorption plays a predominating role in the hydrogen storage process on solid surfaces. The adsorption is a spontaneous process, which is caused by interaction between gas molecules and surface, hence, it is always exothermic process and observed as adsorption heats. For this reason, direct measurement of the adsorption heats by adsorption micro-calorimetry would provide quantitative information on the strength of adsorption interaction and the adsorption mechanism. However, the adsorption amounts of hydrogen on carbon materials are far less than those of condensable vapors near room temperature due to low critical temperature of hydrogen (33.2 K), therefore, the adsorption heats can not be determined accurately at conventional measurement conditions near room temperature and the atmospheric pressure. This contribution reports the calorimetric characterization of hydrogen adsorption on nano-porous carbon materials at low temperature and high-pressure conditions. The high-pressure adsorption apparatus consists of a volumetric adsorption line connected to a twin-conduction type microcalorimeter. Activated carbon fibers (ACF, Ad'all Co.) of different micro-pore sizes (Table 1) were used as model adsorbents. Each ACF has slit-shaped micropores of uniform size. The adsorption isotherms and differential heats of adsorption at high-pressure region from 0 to 10 MPa were simultaneously measured at isothermal condition from 203 to 298 K. The adsorption isotherms on ACF were of Henry type regardless of adsorption temperature and pore width; the uptakes increased linearly with equilibrium pressure. The adsorption isotherm at lower sorption temperature tended to show higher sorptivity. The

  18. Direct measurements of adsorption heats of hydrogen on nano-porous carbons

    International Nuclear Information System (INIS)

    Akihiko, Matsumoto; Kazumasa, Yamamoto; Tomoyuki, Miyata

    2005-01-01

    Since a exciting report of hydrogen storage in single-walled carbon nano-tubes by Dillon and his colleagues [1], nano-porous carbon materials, such as carbon nano-tubes, carbon nano-horns and micro-porous activated carbon, have attracted considerable attention as hydrogen storage materials. Adsorption plays a predominating role in the hydrogen storage process on solid surfaces. The adsorption is a spontaneous process, which is caused by interaction between gas molecules and surface, hence, it is always exothermic process and observed as adsorption heats. For this reason, direct measurement of the adsorption heats by adsorption microcalorimetry would provide quantitative information on the strength of adsorption interaction and the adsorption mechanism. However, the adsorption amounts of hydrogen on carbon materials are far less than those of condensable vapors near room temperature due to low critical temperature of hydrogen (33.2 K), therefore, the adsorption heats can not be determined accurately at conventional measurement conditions near room temperature and the atmospheric pressure. This contribution reports the calorimetric characterization of hydrogen adsorption on nano-porous carbon materials at low temperature and high-pressure conditions. The high-pressure adsorption apparatus consists of a volumetric adsorption line connected to a twin-conduction type microcalorimeter. Activated carbon fibers (ACF, Ad'all Co.) of different micropore sizes (Table 1) were used as model adsorbents. Each ACF has slit-shaped micropores of uniform size [2]. The adsorption isotherms and differential heats of adsorption at high-pressure region from 0 to 10 MPa were simultaneously measured at isothermal condition from 203 to 298 K. The adsorption isotherms on ACF were of Henry type regardless of adsorption temperature and pore width; the uptakes increased linearly with equilibrium pressure. The adsorption isotherm at lower sorption temperature tended to show higher sorptivity

  19. Aerosol direct effect on solar radiation over the eastern Mediterranean Sea based on AVHRR satellite measurements

    Science.gov (United States)

    Georgakaki, Paraskevi; Papadimas, Christos D.; Hatzianastassiou, Nikos; Fotiadi, Aggeliki; Matsoukas, Christos; Stackhouse, Paul; Kanakidou, Maria; Vardavas, Ilias M.

    2017-04-01

    Despite the improved scientific understanding of the direct effect of aerosols on solar radiation (direct radiative effect, DRE) improvements are necessary, for example regarding the accuracy of the magnitude of estimated DREs and their spatial and temporal variability. This variability cannot be ensured by in-situ surface and airborne measurements, while it is also relatively difficult to capture through satellite observations. This becomes even more difficult when complete spatial coverage of extended areas is required, especially concerning areas that host various aerosol types with variable physico-chemical and optical aerosol properties. Better assessments of aerosol DREs are necessary, relying on aerosol optical properties with high spatial and temporal variation. The present study aims to provide a refined, along these lines, assessment of aerosol DREs over the eastern Mediterranean (EM) Sea, which is a key area for aerosol studies. Daily DREs are computed for 1˚ x1˚ latitude-longitude grids with the FORTH detailed spectral radiation transfer model (RTM) using input data for various atmospheric and surface parameters, such as clouds, water vapor, ozone and surface albedo, taken from the NASA-Langley Global Earth Observing System (GEOS) database. The model spectral aerosol optical depth (AOD), single scattering albedo and asymmetry parameter are taken from the Global Aerosol Data Set and the NOAA Climate Data Record (CDR) version 2 of Advanced Very High resolution Radiometer (AVHRR) AOD dataset which is available over oceans at 0.63 microns and at 0.1˚ x0.1˚ . The aerosol DREs are computed at the surface, the top-of-atmosphere and within the atmosphere, over the period 1985-1995. Preliminary model results for the period 1990-1993 reveal a significant spatial and temporal variability of DREs over the EM Sea, for example larger values over the Aegean and Black Seas, surrounded by land areas with significant anthropogenic aerosol sources, and over the

  20. IR thermocycler for centrifugal microfluidic platform with direct on-disk wireless temperature measurement system

    Science.gov (United States)

    Burger, J.; Gross, A.; Mark, D.; Roth, G.; von Stetten, F.; Zengerle, R.

    2011-06-01

    The direct on-disk wireless temperature measurement system [1,2] presented at μTAS 2010 was further improved in its robustness. We apply it to an IR thermocycler as part of a centrifugal microfluidic analyzer for polymerase chain reactions (PCR). This IR thermocycler allows the very efficient direct heating of aqueous liquids in microfluidic cavities by an IR radiation source. The efficiency factor of this IR heating system depends on several parameters. First there is the efficiency of the IR radiator considering the transformation of electrical energy into radiation energy. This radiation energy needs to be focused by a reflector to the center of the cavity. Both, the reflectors shape and the quality of the reflecting layer affect the efficiency. On the way to the center of the cavity the radiation energy will be diminished by absorption in the surrounding air/humidity and especially in the cavity lid of the microfluidic disk. The transmission spectrum of the lid material and its thickness is of significant impact. We chose a COC polymer film with a thickness of 150 μm. At a peak frequency of the IR radiator of ~2 μm approximately 85 % of the incoming radiation energy passes the lid and is absorbed within the first 1.5 mm depth of liquid in the cavity. As we perform the thermocycling for a PCR, after heating to the denaturation temperature of ~ 92 °C we need to cool down rapidly to the primer annealing temperature of ~ 55 °C. Cooling is realized by 3 ventilators venting air of room temperature into the disk chamber. Due to the air flow itself and an additional rotation of the centrifugal microfluidic disk the PCR reagents in the cavities are cooled by forced air convection. Simulation studies based upon analogous electrical models enable to optimize the disk geometry and the optical path. Both the IR heater and the ventilators are controlled by the digital PID controller HAPRO 0135 [3]. The sampling frequency is set to 2 Hz. It could be further increased up

  1. Study of the directional spectrum of ocean waves using array, buoy and radar measurements

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A.

    Phase/time/path difference (PTPD) methods of Esteva [1977] and Borgman [1974] with two modifications, viz., true phase and coherence proposed in this thesis, have for the first time been successfully used for computing wave direction as a function...

  2. A novel method for direct measurement of complement convertases activity in human serum

    NARCIS (Netherlands)

    Blom, A.M.; Volokhina, E.B.; Fransson, V.; Stromberg, P.; Berghard, L.; Viktorelius, M.; Mollnes, T.E.; Lopez-Trascasa, M.; Heuvel, B. van den; Goodship, T.H.; Marchbank, K.J.; Okroj, M.

    2014-01-01

    Complement convertases are enzymatic complexes that play a central role in sustaining and amplification of the complement cascade. Impairment of complement function leads directly or indirectly to pathological conditions, including higher infection rate, kidney diseases, autoimmune- or

  3. Volatility measurement with directional change in Chinese stock market: Statistical property and investment strategy

    Science.gov (United States)

    Ma, Junjun; Xiong, Xiong; He, Feng; Zhang, Wei

    2017-04-01

    The stock price fluctuation is studied in this paper with intrinsic time perspective. The event, directional change (DC) or overshoot, are considered as time scale of price time series. With this directional change law, its corresponding statistical properties and parameter estimation is tested in Chinese stock market. Furthermore, a directional change trading strategy is proposed for invest in the market portfolio in Chinese stock market, and both in-sample and out-of-sample performance are compared among the different method of model parameter estimation. We conclude that DC method can capture important fluctuations in Chinese stock market and gain profit due to the statistical property that average upturn overshoot size is bigger than average downturn directional change size. The optimal parameter of DC method is not fixed and we obtained 1.8% annual excess return with this DC-based trading strategy.

  4. Residual DNA analysis in biologics development: review of measurement and quantitation technologies and future directions.

    Science.gov (United States)

    Wang, Xing; Morgan, Donna M; Wang, Gan; Mozier, Ned M

    2012-02-01

    Residual DNA (rDNA) is comprised of deoxyribonucleic acid (DNA) fragments and longer length molecules originating from the host organism that may be present in samples from recombinant biological processes. Although similar in basic structural base pair units, rDNA may exist in different sizes and physical forms. Interest in measuring rDNA in recombinant products is based primarily on demonstration of effective purification during manufacturing, but also on some hypothetical concerns that, in rare cases, depending on the host expression system, some DNA sequences may be potentially infectious or oncogenic (e.g., HIV virus and the Ras oncogene, respectively). Recent studies suggest that a sequence known as long interspersed nucleotide element-1 (LINE-1), widely distributed in the mammalian genome, is active as a retrotransposon that can be transcribed to RNA, reverse-transcribed into DNA and inserts into a new site in genome. This integration process could potentially disrupt critical gene functions or induce tumorigenesis in mammals. Genomic DNA from microbial sources, on the other hand, could add to risk of immunogenicity to the target recombinant protein being expressed, due to the high CpG content and unmethylated DNA sequence. For these and other reasons, it is necessary for manufacturers to show clearance of DNA throughout production processes and to confirm low levels in the final drug substance using an appropriately specific and quantitative analytical method. The heterogeneity of potential rDNA sequences that might be makes the testing of all potential analytes challenging. The most common methodology for rDNA quantitation used currently is real-time polymerase chain reaction (RT-PCR), a robust and proven technology. Like most rDNA quantitation methods, the specificity of RT-PCR is limited by the sequences to which the primers are directed. To address this, primase-based whole genome amplification is introduced herein. This paper will review the recent

  5. Fiscal policy and TFP in the OECD: Measuring direct and indirect effects

    OpenAIRE

    Everaert, Gerdie; Heylen, Freddy; Schoonackers, Ruben

    2014-01-01

    This paper analyzes the direct and indirect effects of fiscal policy on total factor productivity (TFP) in a panel of OECD countries over the period 1970-2012. Our contribution is twofold. First, when estimating the impact of fiscal policy on TFP from a production function approach, we identify the worldwide available level of technology by exploiting the observed strong cross-sectional dependence between countries instead of using ad hoc proxies for technology. Second, next to direct effects...

  6. Farmer-to-Consumer Direct Marketing: The Role of Customer Satisfaction Measurement for Service Innovations

    OpenAIRE

    Spiller, Achim; Zuhlsdorf, Anke; Mellin, Matthias

    2007-01-01

    The importance of direct marketing for high quality farm products has increased during the past few years. This paper analyses the impact of customer satisfaction and its driving forces for farmer- to-consumer direct marketing and is based on a customer survey in 33 organic and conventional on-farm stores in Germany. The results emphasise the role of store atmosphere and customer service as the main influencing factors on customer satisfaction.

  7. A Novel Multiparty Quantum Secret Sharing Scheme of Secure Direct Communication Based on Bell States and Bell Measurements

    International Nuclear Information System (INIS)

    Shi Run-Hua; Huang Liu-Sheng; Yang Wei; Zhong Hong

    2011-01-01

    We present a novel quantum secret sharing scheme of secure direct communication and analyze its security. This scheme takes Einstein—Podolsky—Rosen (EPR) pairs in Bell states as quantum resources. In order to obtain the direct communication message, all agents only need to perform Bell measurements, not to perform any local unitary operation. The total efficiency in this scheme approaches 100% as the classical information exchanged is unnecessary except for the eavesdropping checks. (general)

  8. Thyroid doses in Belarus resulting from the Chernobyl accident: comparison of the estimates based on direct thyroid measurements and on measurements of 131I in milk

    International Nuclear Information System (INIS)

    Shinkarev, Sergey; Gavrilin, Yury; Khrouch, Valery; Savkin, Mikhail; Bouville, Andre; Luckyanov, Nicholas

    2008-01-01

    A substantial increase of childhood cancer cases observed in Belarus, Ukraine and Russia after the Chernobyl accident has been associated with thyroid exposure to radio iodines following the accident. A large number of direct thyroid measurements (i.e. measurement of the exposure rate near the thyroid of the subject)were conducted in Belarus during a few weeks after the accident. Individual thyroid doses based on results of the direct thyroid measurements were estimated for about 126,000 Belarusian residents and settlement-average thyroid doses for adults were calculated for 426 contaminated settlements in Gomel and Mogilev Oblasts. Another set of settlement-average thyroid doses for adults was estimated based on results of activity measurements in milk samples for 28 settlements (with not less than 2 spectrometric measurements) and 155 settlements (with not less than 5 total beta-activity measurements) in Gomel and Mogilev Oblasts. Concentrations of 131 I in milk were derived from these measurements. In the estimation of this set of thyroid doses, it was assumed that adults consumed 0.5 L d -1 of milk locally produced. The two sets of dose estimates were compared for 47 settlements, for which simultaneously were available a dose estimate based on thyroid measurements and a dose estimate based either on spectrometric or radiometric milk data. The settlement average thyroid doses based on milk activity measurements were higher than those based on direct thyroid measurements by a factor of 1.8 for total beta-activity measurements (30 settlements were compared) and by a factor of 2.4 for spectrometric measurements (17 settlements). This systematic difference can be explained by overestimation of the milk consumption rate used in the calculation of the milk-based thyroid doses and/or by application of individual countermeasures by people. (author)

  9. A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review

    Directory of Open Access Journals (Sweden)

    Hardt Jill

    2008-11-01

    Full Text Available Abstract Background Accurate assessment is required to assess current and changing physical activity levels, and to evaluate the effectiveness of interventions designed to increase activity levels. This study systematically reviewed the literature to determine the extent of agreement between subjectively (self-report e.g. questionnaire, diary and objectively (directly measured; e.g. accelerometry, doubly labeled water assessed physical activity in adults. Methods Eight electronic databases were searched to identify observational and experimental studies of adult populations. Searching identified 4,463 potential articles. Initial screening found that 293 examined the relationship between self-reported and directly measured physical activity and met the eligibility criteria. Data abstraction was completed for 187 articles, which described comparable data and/or comparisons, while 76 articles lacked comparable data or comparisons, and a further 30 did not meet the review's eligibility requirements. A risk of bias assessment was conducted for all articles from which data was abstracted. Results Correlations between self-report and direct measures were generally low-to-moderate and ranged from -0.71 to 0.96. No clear pattern emerged for the mean differences between self-report and direct measures of physical activity. Trends differed by measure of physical activity employed, level of physical activity measured, and the gender of participants. Results of the risk of bias assessment indicated that 38% of the studies had lower quality scores. Conclusion The findings suggest that the measurement method may have a significant impact on the observed levels of physical activity. Self-report measures of physical activity were both higher and lower than directly measured levels of physical activity, which poses a problem for both reliance on self-report measures and for attempts to correct for self-report – direct measure differences. This review reveals

  10. Direct measurements of secondary water inventory of steam generator PGV-213 in operation

    Energy Technology Data Exchange (ETDEWEB)

    Tarankov, G.A.; Trunov, N.B.; Dranchenko, B.N.; Kamiagin, W.W. [OKB Gidropress (Russian Federation)

    1997-12-31

    Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

  11. Evaluation of the usefulness of smartphone-directed applications for measuring heart rate and arrhythmia detection

    Directory of Open Access Journals (Sweden)

    Michał Witkowski

    2017-12-01

    Conclusions: The majority of the free applications, available for smartphones, are able to measure HR precisely in patients with sinus rhythm, while in patients with AF, the exact measurement is significantly impeded by HR deficits. Only one out of 16 applications was able to measure HR in a patient with AF. None of the available applications could detect AF.

  12. Direct measurements of secondary water inventory of steam generator PGV-213 in operation

    Energy Technology Data Exchange (ETDEWEB)

    Tarankov, G A; Trunov, N B; Dranchenko, B N; Kamiagin, W W [OKB Gidropress (Russian Federation)

    1998-12-31

    Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

  13. Performances of a HGCDTE APD based direct detection lidar at 2 μm. Application to dial measurements

    Science.gov (United States)

    Gibert, Fabien; Dumas, Arnaud; Rothman, Johan; Edouart, Dimitri; Cénac, Claire; Pellegrino, Jessica

    2018-04-01

    A lidar receiver with a direct detection chain adapted to a HgCdTe APD based detector with electric cooling is associated to a 2.05 μm Ho :YLF pulsed dual wavelength single mode transmitter to provide the first atmospheric lidar measurements using this technology. Experiments confirm the outstanding sensitivity of the detector and hightligth its huge potential for DIAL measurements of trace gas (CO2 and H2O) in this spectral domain. Performances of coherent vs direct detection at 2.05 μm is assessed.

  14. Performances of a HGCDTE APD based direct detection lidar at 2 μm. Application to dial measurements

    Directory of Open Access Journals (Sweden)

    Gibert Fabien

    2018-01-01

    Full Text Available A lidar receiver with a direct detection chain adapted to a HgCdTe APD based detector with electric cooling is associated to a 2.05 μm Ho :YLF pulsed dual wavelength single mode transmitter to provide the first atmospheric lidar measurements using this technology. Experiments confirm the outstanding sensitivity of the detector and hightligth its huge potential for DIAL measurements of trace gas (CO2 and H2O in this spectral domain. Performances of coherent vs direct detection at 2.05 μm is assessed.

  15. Direct speed of sound measurement within the atmosphere during a national holiday in New Zealand

    Science.gov (United States)

    Vollmer, M.

    2018-05-01

    Measuring the speed of sound belongs to almost any physics curriculum. Two methods dominate, measuring resonance phenomena of standing waves or time-of-flight measurements. The second type is conceptually simpler, however, performing such experiments with dimensions of meters usually requires precise electronic time measurement equipment if accurate results are to be obtained. Here a time-of-flight measurement from a video recording is reported with a dimension of several km and an accuracy for the speed of sound of the order of 1%.

  16. Local viscoelastic response of direct and indirect dental restorative composites measured by AFM.

    Science.gov (United States)

    Grattarola, Laura; Derchi, Giacomo; Diaspro, Alberto; Gambaro, Carla; Salerno, Marco

    2018-06-08

    We investigated the viscoelastic response of direct and indirect dental restorative composites by the novel technique of AM-FM atomic force microscopy. We selected four composites for direct restorations (Adonis, Optifil, EPH, CME) and three composites for indirect restorations (Gradia, Estenia, Signum). Scanning electron microscopy with micro-analysis was also used to support the results. The mean storage modulus of all composites was in the range of 10.2-15.2 GPa. EPH was the stiffest (pcomposites but Adonis and Estenia), while no significant difference was observed between direct and indirect group (p≥0.05). For the loss tangent, Gradia had the highest value (~0.3), different (pcomposites showed higher loss tangent (pcomposites. All composites exhibited minor contrast at the edge of fillers, showing that these are pre-polymerized, as confirmed by EDS.

  17. Constraining the 19Ne(p,γ)20Na Reaction Rate Using a Direct Measurement at DRAGON

    Science.gov (United States)

    Wilkinson, R.; Lotay, G.; Lennarz, A.; Ruiz, C.; Christian, G.; Akers, C.; Catford, W. N.; Chen, A. A.; Connolly, D.; Davids, B.; Hutcheon, D. A.; Jedrejcic, D.; Laird, A. M.; Martin, L.; McNeice, E.; Riley, J.; Williams, M.

    2018-01-01

    A direct measurement of the 19Ne(p, γ)20 Na reaction has been performed in inverse kinematics at the DRAGON recoil separator, at an energy ˜ 10 keV higher than previous measurements. The key resonance in the 19 Ne + p system relevant for ONe novae and Type-I X-ray burst temperatures have been successfully measured for the first time. Preliminary estimates of the resonance energy and strength are reported as Ec.m. ≈ 458 keV and ωγ ≈ 18 meV. These results are consistent with previous direct measurements, but disagree with the most recent study of the 19Ne(p, γ)20 Na reaction rate. These preliminary results will be finalised after a forthcoming negative log-likelihood analysis.

  18. Feasibility of direct reactivity measurement in multi-canister overpacks at the Cold Vacuum Drying Facility

    International Nuclear Information System (INIS)

    Cowan, R.G.

    1997-01-01

    A proposed method for measuring the chemical reaction rate (power) of breached N-Reactor fuel elements with water in a Multi-canister overpack (MCO) based on hydrogen release rate is evaluated. The reaction rate is measured at 50 C in an oxygen free water by applying a vacuum to boil the water and adding a low, measured flow of helium. The ratio of helium to hydrogen is used to infer the reaction rate. A test duration of less than 8 hours was found to provide sufficient accuracy for confidence in the measurement results. A more rigorous treatment of system measurement accuracy, which may yield shorter test durations, should be performed if this reactivity measurement is to be employed

  19. An Approach to Dynamic Line Rating State Estimation at Steady State Using Direct and Indirect Measurements

    DEFF Research Database (Denmark)

    Alvarez, David; Silva, Filipe Miguel Faria da; Mombello, Enrique E.

    2018-01-01

    Dynamic line rating has emerged as a solution for reducing congestion in overhead lines, allowing the optimization of power systems assets. This technique is based on direct and/or indirect monitoring of conductor temperature. Different devices and methods have been developed to sense conductor...

  20. Measurements of Dermal Uptake of Nicotine Directly from Air and Clothing

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Morrison, Glenn; Weschler, Charles J.

    2016-01-01

    Dermal uptake directly from air is a significant contributor to total exposure for certain organic compounds, and has been recently experimentally verified for two phthalates. The objective of the current study was to investigate whether airborne nicotine can be dermally absorbed. Two bare-skinne...

  1. Measurements of dermal uptake of nicotine directly from air and clothing

    DEFF Research Database (Denmark)

    Beko, G.; Morrison, G.; Weschler, Charles J.

    2017-01-01

    In this preliminary study, we have investigated whether dermal uptake of nicotine directly from air or indirectly from clothing can be a meaningful exposure pathway. Two participants wearing only shorts and a third participant wearing clean cotton clothes were exposed to environmental tobacco smo...

  2. Direct Measurement of Power Dissipated by Monte Carlo Simulations on CPU and FPGA Platforms

    OpenAIRE

    Albicocco, Pietro; Papini, Davide; Nannarelli, Alberto

    2012-01-01

    In this technical report, we describe how power dissipation measurements on different computing platforms (a desktop computer and an FPGA board) are performed by using a Hall effectbased current sensor. The chosen application is a Monte Carlo simulation for European option pricing which is a popular algorithm used in financial computations. The Hall effect probe measurements complement the measurements performed on the core of the FPGA by a built-in Xilinxpower monitoring system.

  3. Direct microscopic image and measurement of the atomization process of a port fuel injector

    International Nuclear Information System (INIS)

    Esmail, Mohamed; Kawahara, Nobuyuki; Tomita, Eiji; Sumida, Mamoru

    2010-01-01

    The main objective of this study is to observe and investigate the phenomena of atomization, i.e. the fuel break-up process very close to the nozzle exit of a practical port fuel injector (PFI). In order to achieve this objective, direct microscopic images of the atomization process were obtained using an ultra-high-speed video camera that could record 102 frames at rates of up to 1 Mfps, coupled with a long-distance microscope and Barlow lens. The experiments were carried out using a PFI in a closed chamber at atmospheric pressure. Time-series images of the spray behaviour were obtained with a high temporal resolution using backlighting. The direct microscopic images of a liquid column break-up were compared with experimental results from laser-induced exciplex fluorescence (LIEF), and the wavelength obtained from the experimental results compared with that predicated from the Kelvin–Helmholtz break-up model. The droplet size diameters from a ligament break-up were compared with results predicated from Weber's analysis. Furthermore, experimental results of the mean droplet diameter from a direct microscopic image were compared with the results obtained from phase Doppler anemometry (PDA) experimental results. Three conclusions were obtained from this study. The atomization processes and detailed characterizations of the break-up of a liquid column were identified; the direct microscopic image results were in good agreement with the results obtained from LIEF, experimental results of the wavelength were in good agreement with those from the Kelvin–Helmholtz break-up model. The break-up process of liquid ligaments into droplets was investigated, and Weber's analysis of the predicated droplet diameter from ligament break-up was found to be applicable only at larger wavelengths. Finally, the direct microscopic image method and PDA method give qualitatively similar trends for droplet size distribution and quantitatively similar values of Sauter mean diameter

  4. Direct microscopic image and measurement of the atomization process of a port fuel injector

    Science.gov (United States)

    Esmail, Mohamed; Kawahara, Nobuyuki; Tomita, Eiji; Sumida, Mamoru

    2010-07-01

    The main objective of this study is to observe and investigate the phenomena of atomization, i.e. the fuel break-up process very close to the nozzle exit of a practical port fuel injector (PFI). In order to achieve this objective, direct microscopic images of the atomization process were obtained using an ultra-high-speed video camera that could record 102 frames at rates of up to 1 Mfps, coupled with a long-distance microscope and Barlow lens. The experiments were carried out using a PFI in a closed chamber at atmospheric pressure. Time-series images of the spray behaviour were obtained with a high temporal resolution using backlighting. The direct microscopic images of a liquid column break-up were compared with experimental results from laser-induced exciplex fluorescence (LIEF), and the wavelength obtained from the experimental results compared with that predicated from the Kelvin-Helmholtz break-up model. The droplet size diameters from a ligament break-up were compared with results predicated from Weber's analysis. Furthermore, experimental results of the mean droplet diameter from a direct microscopic image were compared with the results obtained from phase Doppler anemometry (PDA) experimental results. Three conclusions were obtained from this study. The atomization processes and detailed characterizations of the break-up of a liquid column were identified; the direct microscopic image results were in good agreement with the results obtained from LIEF, experimental results of the wavelength were in good agreement with those from the Kelvin-Helmholtz break-up model. The break-up process of liquid ligaments into droplets was investigated, and Weber's analysis of the predicated droplet diameter from ligament break-up was found to be applicable only at larger wavelengths. Finally, the direct microscopic image method and PDA method give qualitatively similar trends for droplet size distribution and quantitatively similar values of Sauter mean diameter.

  5. Research on corrosion mechanism of suspension insulator steel foot of direct current system and measures for corrosion inhibition

    Science.gov (United States)

    Chen, He; Yang, Yueguang; Su, Guolei; Wang, Xiaoqing; Zhang, Hourong; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    There are increasingly serious electrocorrosion phenomena on insulator hardware caused by direct current transmission due to the wide-range popularization of extra high voltage direct current transmission engineering in our country. Steel foot corrosion is the main corrosion for insulators on positive polarity side of transmission lines. On one hand, the corrosion leads to the tapering off of steel foot diameter, having a direct influence on mechanical property of insulators; on the other hand, in condition of corrosion on steel foot wrapped in porcelain ware, the volume of the corrosion product is at least 50% more than that of the original steel foot, leading to bursting of porcelain ware, threatening safe operation of transmission lines. Therefore, it is necessary to conduct research on the phenomenon and propose feasible measures for corrosion inhibition. Starting with the corrosion mechanism, this article proposes two measures for corrosion inhibition, and verifies the inhibition effect in laboratory conditions, providing reference for application in engineering.

  6. Estimates of oceanic surface wind speed and direction using orthogonal beam scatterometer measurements and comparison of recent sea scattering theories

    Science.gov (United States)

    Moore, R. K.; Fung, A. K.; Dome, G. J.; Birrer, I. J.

    1978-01-01

    The wind direction properties of radar backscatter from the sea were empirically modelled using a cosine Fourier series through the 4th harmonic in wind direction (referenced to upwind). A comparison with 1975 JONSWAP (Joint North Sea Wave Project) scatterometer data, at incidence angles of 40 and 65, indicates that effects to third and fourth harmonics are negligible. Another important result is that the Fourier coefficients through the second harmonic are related to wind speed by a power law expression. A technique is also proposed to estimate the wind speed and direction over the ocean from two orthogonal scattering measurements. A comparison between two different types of sea scatter theories, one type presented by the work of Wright and the other by that of Chan and Fung, was made with recent scatterometer measurements. It demonstrates that a complete scattering model must include some provisions for the anisotropic characteristics of the sea scatter, and use a sea spectrum which depends upon wind speed.

  7. Stigma and Intellectual Disability: A Review of Related Measures and Future Directions

    Science.gov (United States)

    Werner, Shirli; Corrigan, Patrick; Ditchman, Nicole; Sokol, Kristin

    2012-01-01

    The theoretical construct of stigma has received much attention in psychiatric disability research, leading to the development of widely used measures. Such measures have had real world impact in that they allow for the assessment of stigma change efforts. The study of stigma has not received the same level of attention for persons with…

  8. Direct measurement of resistance of multiwalled carbon nanotubes using micro four-point probes

    DEFF Research Database (Denmark)

    Dohn, Søren; Mølhave, Kristian; Bøggild, Peter

    2005-01-01

    -point resistance at specific positions along the nanotubes, was measured by microprobes with different microelectrocle spacings. Individual nanotubes were investigated in more detail by measuring current as a function of bias voltage until the point of failure and the results are compared to previously reported...

  9. Direct measurement of gas solubilities in polymers with a high-pressure microbalance

    DEFF Research Database (Denmark)

    von Solms, Nicolas; Nielsen, Johannes Kristoffer; Hassager, Ole

    2004-01-01

    for methane, for which negative deviations from Henry's law behavior were observed. The diffusion coefficients for each of the gases in the polymer were also measured with the balance, although the uncertainty was greater than for the solubility measurements. (C) 2003 Wiley Periodicals, Inc. J Appl Polyrn Sci...

  10. Predictors of Social Skills for Preschool Children at Risk for ADHD: The Relationship between Direct and Indirect Measurements

    Science.gov (United States)

    Thomas, Lisa B.; Shapiro, Edward S.; DuPaul, George J.; Lutz, J. Gary; Kern, Lee

    2011-01-01

    The relationship between direct and indirect measurements of social skills and social problem behaviors for preschool children at risk for attention deficit hyperactivity disorder (ADHD) was examined. Participants included 137 preschool children, aged 3 to 5 years, at risk for ADHD, who were participating in a larger study examining the effects of…

  11. Interpretation of deep directional resistivity measurements acquired in high-angle and horizontal wells using 3-D inversion

    Science.gov (United States)

    Puzyrev, Vladimir; Torres-Verdín, Carlos; Calo, Victor

    2018-05-01

    The interpretation of resistivity measurements acquired in high-angle and horizontal wells is a critical technical problem in formation evaluation. We develop an efficient parallel 3-D inversion method to estimate the spatial distribution of electrical resistivity in the neighbourhood of a well from deep directional electromagnetic induction measurements. The methodology places no restriction on the spatial distribution of the electrical resistivity around arbitrary well trajectories. The fast forward modelling of triaxial induction measurements performed with multiple transmitter-receiver configurations employs a parallel direct solver. The inversion uses a pre-conditioned gradient-based method whose accuracy is improved using the Wolfe conditions to estimate optimal step lengths at each iteration. The large transmitter-receiver offsets, used in the latest generation of commercial directional resistivity tools, improve the depth of investigation to over 30 m from the wellbore. Several challenging synthetic examples confirm the feasibility of the full 3-D inversion-based interpretations for these distances, hence enabling the integration of resistivity measurements with seismic amplitude data to improve the forecast of the petrophysical and fluid properties. Employing parallel direct solvers for the triaxial induction problems allows for large reductions in computational effort, thereby opening the possibility to invert multiposition 3-D data in practical CPU times.

  12. Depth-kymography of vocal fold vibrations : part II. Simulations and direct comparisons with 3D profile measurements

    NARCIS (Netherlands)

    de Mul, Frits F. M.; George, Nibu A.; Qiu, Qingjun; Rakhorst, Gerhard; Schutte, Harm K.

    2009-01-01

    We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is

  13. Direct measurement of the cross section of neutron-neutron scattering at the YAGUAR reactor. Substantiation of the experiment technique

    International Nuclear Information System (INIS)

    Chernukhin, Yu.G.; Kandiev, Ya.Z.; Lartsev, V.D.; Levakov, B.G.; Modestov, D.G.; Simonenko, V.A.; Streltsov, S.I.; Khmel'nitskij, D.V.

    2006-01-01

    The main stage of experiment for direct measurement of cross section of neutron-neutron scattering σ nn at low energies (E nn determination. It was shown, that for achieving the criterion ε ∼ 4% it will be necessary to have 40-50 pulses of a reactor [ru

  14. Flying with the wind: Scale dependency of speed and direction measurements in modelling wind support in avian flight

    Science.gov (United States)

    Safi, Kamran; Kranstauber, Bart; Weinzierl, Rolf P.; Griffin, Larry; Reese, Eileen C.; Cabot, David; Cruz, Sebastian; Proaño, Carolina; Takekawa, John Y.; Newman, Scott H.; Waldenström, Jonas; Bengtsson, Daniel; Kays, Roland; Wikelski, Martin; Bohrer, Gil

    2013-01-01

    Background: Understanding how environmental conditions, especially wind, influence birds' flight speeds is a prerequisite for understanding many important aspects of bird flight, including optimal migration strategies, navigation, and compensation for wind drift. Recent developments in tracking technology and the increased availability of data on large-scale weather patterns have made it possible to use path annotation to link the location of animals to environmental conditions such as wind speed and direction. However, there are various measures available for describing not only wind conditions but also the bird's flight direction and ground speed, and it is unclear which is best for determining the amount of wind support (the length of the wind vector in a bird’s flight direction) and the influence of cross-winds (the length of the wind vector perpendicular to a bird’s direction) throughout a bird's journey.Results: We compared relationships between cross-wind, wind support and bird movements, using path annotation derived from two different global weather reanalysis datasets and three different measures of direction and speed calculation for 288 individuals of nine bird species. Wind was a strong predictor of bird ground speed, explaining 10-66% of the variance, depending on species. Models using data from different weather sources gave qualitatively similar results; however, determining flight direction and speed from successive locations, even at short (15 min intervals), was inferior to using instantaneous GPS-based measures of speed and direction. Use of successive location data significantly underestimated the birds' ground and airspeed, and also resulted in mistaken associations between cross-winds, wind support, and their interactive effects, in relation to the birds' onward flight.Conclusions: Wind has strong effects on bird flight, and combining GPS technology with path annotation of weather variables allows us to quantify these effects for

  15. Fast and direct measurements of the electrical properties of graphene using micro four-point probes

    International Nuclear Information System (INIS)

    Klarskov, M B; Dam, H F; Petersen, D H; Hansen, T M; Loewenborg, A; Booth, T J; Schmidt, M S; Boeggild, P; Lin, R; Nielsen, P F

    2011-01-01

    We present measurements of the electronic properties of graphene using a repositionable micro four-point probe system, which we show here to have unique advantages over measurements made on lithographically defined devices; namely speed, simplicity and lack of a need to pattern graphene. Measurements are performed in ambient, vacuum and controlled environmental conditions using an environmental scanning electron microscope (SEM). The results are comparable to previous results for microcleaved graphene on silicon dioxide (SiO 2 ). We observe a pronounced hysteresis of the charge neutrality point, dependent on the sweep rate of the gate voltage; and environmental measurements provide insight into the sensor application prospects of graphene. The method offers a fast, local and non-destructive technique for electronic measurements on graphene, which can be positioned freely on a graphene flake.

  16. Relating Direct Methanol Fuel Cell Performance to Measurements in a Liquid Half Cell

    DEFF Research Database (Denmark)

    Pedersen, Christoffer Mølleskov; Tynelius, Oskar; Lund-Olesen, Torsten

    2015-01-01

    Direct methanol fuel cells (DMFC) could act as a replacement for batteries in low power electronics. For instance, micro—DMFC’s could be used to power hearing instruments[1]. The power output of a DMFC is limited by the sluggish kinetics of both the methanol oxidation reaction (MOR) on the anode ...... Cells Bull. 2012 (2012) 12–16. doi:10.1016/S1464-2859(12)70367-X....

  17. Measurement of integrated healthcare delivery: a systematic review of methods and future research directions

    Directory of Open Access Journals (Sweden)

    Martin Strandberg-Larsen

    2009-02-01

    Full Text Available Background: Integrated healthcare delivery is a policy goal of healthcare systems. There is no consensus on how to measure the concept, which makes it difficult to monitor progress. Purpose: To identify the different types of methods used to measure integrated healthcare delivery with emphasis on structural, cultural and process aspects. Methods: Medline/Pubmed, EMBASE, Web of Science, Cochrane Library, WHOLIS, and conventional internet search engines were systematically searched for methods to measure integrated healthcare delivery (published – April 2008. Results: Twenty-four published scientific papers and documents met the inclusion criteria. In the 24 references we identified 24 different measurement methods; however, 5 methods shared theoretical framework. The methods can be categorized according to type of data source: a questionnaire survey data, b automated register data, or c mixed data sources. The variety of concepts measured reflects the significant conceptual diversity within the field, and most methods lack information regarding validity and reliability. Conclusion: Several methods have been developed to measure integrated healthcare delivery; 24 methods are available and some are highly developed. The objective governs the method best used. Criteria for sound measures are suggested and further developments should be based on an explicit conceptual framework and focus on simplifying and validating existing methods.

  18. Androgen radioimmunoassay in the ram: results of direct plasma testosterone and dehydroepiandrosterone measurement and physiological evaluation

    International Nuclear Information System (INIS)

    Garnier, D.-H.; Cotta, Y.; Terqui, M.

    1978-01-01

    Different radioimmunoassays of testosterone (T) dehydroepiandrosterone (DHA) and 5 α-dihydrotestosterone (5 α-DHT) were investigated for ram plasma. Specificity of the antisera, lack of noticeable binding in plasma, very low levels of other androgens allow direct plasma RIA for DHA and T by the double antibody technique. The levels obtained by this simplified method are in agreement with those found after extraction alone, after extraction and celite chromatography and after quantification with a completely different technique such as gas chromatography. The within assay variabilities for T and DHA were 4.7 p. 100 and 4.6 p. 100 respectively but vary with the level of steroid in plasma. The inter assay variabilities of T were 9.5 p. 100 and 3.2 p. 100 for 1.5 and 11.6 ng/ml of plasma respectively. The antiserum for 5 α-DHT have a specificity such that, even after celite chromatography some androgens (5 β-DHT) may interfere. However determinations of 5 α/5 β-DHT amounts are possible. The physiological validations of direct plasma T and DHA RIA were studied in various conditions. The DHA plasma variations are similar to those of T in Ram from birth to puberty, but the levels are lower. DHA plasma levels show a seasonal variation as does testosterone. Variations within 24 hrs of these two androgens were in synchrony. The direct plasma T and DHA assays are useful and inexpensive tools to characterize ram testicular function

  19. Direct measurement of homogeneously distributed radioactive air contamination with germanium detectors

    International Nuclear Information System (INIS)

    Sowa, W.

    1990-01-01

    Air contamination by γ emitting radionuclides was measured with a vertically arranged germanium detector, laterally shielded by a lead ring, and calibration factors and detection limits of a number of fission products determined. The possibility of measuring simultaneously existing air and soil contamination by measurements with and without lead shield is described. The change of detection limit of air contamination is presented for different soil contamination levels by the same radionuclide. Calibration factors are given to determine the dose rate on the ground due to air contamination by different radionuclides. (author)

  20. Controlled drilling technology for HLW management. Directional drilling and mechanics/stress measurements in the borehole

    International Nuclear Information System (INIS)

    Kiho, Kenzo; Shin, Koichi; Okada, Tetsuji; Obuchi, Yasuyoshi; Sunaga, Takayuki; Hase, Kazunori

    2013-01-01

    Since 2000, Central Research Institute of Electric Power Industry (CRIEPI) has been conducting the project on controlled drilling and the logging/measurement technologies in its boreholes. Especially borehole pressure meter and bore hole stress measurement apparatus which can apply to the controlled drilling system was developed. The bore hole was drilled to the 1000 m long in order to intersect the Omagari fault located at Horonobe town in Hokkaido and its core recovery was 99.8% as of FY. 2011. Using borehole logging/measurement/survey, the geological, hydrological, geo-mechanical, geophysical and geochemical data were collected and the Omagari fault was characterized. (author)

  1. Direct Measurement of the Isomerization Barrier of the Isolated Retinal Chromophore

    DEFF Research Database (Denmark)

    Dilger, Jonathan; Musbat, Lihi; Sheves, Mordechai

    2015-01-01

    Isomerizations of the retinal chromophore were investigated using the IMS-IMS technique. Four different structural features of the chromophore were observed, isolated, excited collisionally, and the resulting isomer and fragment distributions were measured. By establishing the threshold activatio...

  2. Performance measures to characterize directional corridor travel time delay based on probe vehicle data : final report.

    Science.gov (United States)

    2015-10-01

    Anonymous probe vehicle data are currently being collected on roadways throughout the United States. These data are being incorporated into local and statewide mobility reports to measure the performance of freeways and arterial systems. Predefined s...

  3. Implementing the water framework directive in Denmark - Lessons on agricultural measures from a legal and regulatory perspective

    DEFF Research Database (Denmark)

    Jacobsen, Brian H.; Anker, Helle Tegner; Baaner, Lasse

    2017-01-01

    One of the major challenges in the implementation of the Water Framework Directive (WFD) is how to address diffuse agricultural pollution of the aquatic environment. In Denmark the implementation of agricultural measures has been fraught with difficulty in the form of delays and legal proceedings...... and a policy failure. It is argued that the adoption of more flexible measures to be implemented at the local level could have resulted in fewer difficulties from an economic and legal point of view as measures could have been applied where there was a clear environmental benefit, and possibly also at a lower...

  4. In-situ permeability measurements with direct push techniques: Phase II topical report

    International Nuclear Information System (INIS)

    Lowry, W.; Mason, N.; Chipman, V.; Kisiel, K.; Stockton, J.

    1999-01-01

    This effort designed, fabricated, and field tested the engineering prototype of the Cone Permeametertrademark system. The integrated system includes the instrumented penetrometer probe, air and water pumps, flowrate controls, flow sensors, and a laptop-controlled data system. All of the equipment is portable and can be transported as luggage on airlines. The data system acquired and displays the process measurements (pressures, flows, and downhole temperature) in real time and calculates the resulting permeability. The measurement probe is a 2 inch diameter CPT rod section, incorporating a screened injection zone near the lower end of the rod and multiple sensitive absolute pressure sensors embedded in the probe at varying distances from the injection zone. Laboratory tests in a large test cell demonstrated the system's ability to measure nominally 1 Darcy permeability soil (30 to 40 Darcy material had been successfully measured in the Phase 1 effort). These tests also provided a shakedown of the system and identified minor instrument problems, which were resolved. Supplemental numerical modeling was conducted to evaluate the effects of layered permeability (heterogeneity) and anisotropy on the measurement system's performance. The general results of the analysis were that the Cone Permeameter could measure accurately, in heterogeneous media, the volume represented by the sample port radii if the outer pressure ports were used. Anisotropic permeability, while readily analyzed numerically, is more complicated to resolve with the simple analytical approach of the 1-D model, and will need further work to quantify. This phase culminated in field demonstrations at the DOE Savannah River Site. Saturated hydraulic conductivity measurements were completed at the D-Area Coal Pile Runoff Basin, and air permeability measurements were conducted at the M Area Integrated Demonstration Site and the 321 M area. The saturated hydraulic conductivity measurements were the most

  5. Pilot-model measurements of pilot responses in a lateral-directional control task

    Science.gov (United States)

    Adams, J. J.

    1976-01-01

    Pilot response during an aircraft bank-angle compensatory control task was measured by using an adaptive modeling technique. In the main control loop, which is the bank angle to aileron command loop, the pilot response was the same as that measured previously in single-input, single-output systems. The pilot used a rudder to aileron control coordination that canceled up to 80 percent of the vehicle yawing moment due to aileron deflection.

  6. Lidiam - direct-link computer for the photo measurement apparatus of a bubble chamber

    International Nuclear Information System (INIS)

    Deler, B.

    1964-01-01

    The treatment of bubble chamber pictures can be considerably improved by connecting conventional measuring machines to a small computer providing continuous control of the later as well as the immediate detection of errors and their immediate corrections. The computer will also perform first processing of the measured data. In addition the system described will improve the effective yield of each apparatus and facilitates the control of the data. A description is given here of the apparatus and of some future extensions. (author) [fr

  7. Direct measurement of adhesion energy of monolayer graphene as-grown on copper and its application to renewable transfer process.

    Science.gov (United States)

    Yoon, Taeshik; Shin, Woo Cheol; Kim, Taek Yong; Mun, Jeong Hun; Kim, Taek-Soo; Cho, Byung Jin

    2012-03-14

    Direct measurement of the adhesion energy of monolayer graphene as-grown on metal substrates is important to better understand its bonding mechanism and control the mechanical release of the graphene from the substrates, but it has not been reported yet. We report the adhesion energy of large-area monolayer graphene synthesized on copper measured by double cantilever beam fracture mechanics testing. The adhesion energy of 0.72 ± 0.07 J m(-2) was found. Knowing the directly measured value, we further demonstrate the etching-free renewable transfer process of monolayer graphene that utilizes the repetition of the mechanical delamination followed by the regrowth of monolayer graphene on a copper substrate. © 2012 American Chemical Society

  8. Direct 3-D morphological measurements of silicone rubber impression using micro-focus X-ray CT.

    Science.gov (United States)

    Kamegawa, Masayuki; Nakamura, Masayuki; Fukui, Yu; Tsutsumi, Sadami; Hojo, Masaki

    2010-01-01

    Three-dimensional computer models of dental arches play a significant role in prosthetic dentistry. The microfocus X-ray CT scanner has the advantage of capturing precise 3D shapes of deep fossa, and we propose a new method of measuring the three-dimensional morphology of a dental impression directly, which will eliminate the conversion process to dental casts. Measurement precision and accuracy were evaluated using a standard gage comprised of steel balls which simulate the dental arch. Measurement accuracy, standard deviation of distance distribution of superimposed models, was determined as +/-0.050 mm in comparison with a CAD model. Impressions and casts of an actual dental arch were scanned by microfocus X-ray CT and three-dimensional models were compared. The impression model had finer morphology, especially around the cervical margins of teeth. Within the limitations of the current study, direct three-dimensional impression modeling was successfully demonstrated using microfocus X-ray CT.

  9. Direct and indirect measurement of the magnetocaloric effect in bulk and nanostructured Ni-Mn-In Heusler alloy

    Science.gov (United States)

    Ghahremani, Mohammadreza; Aslani, Amir; Hosseinnia, Marjan; Bennett, Lawrence H.; Della Torre, Edward

    2018-05-01

    A systematic study of the magnetocaloric effect of a Ni51Mn33.4In15.6 Heusler alloy converted to nanoparticles via high energy ball-milling technique in the temperature range of 270 to 310 K has been performed. The properties of the particles were characterized by x-ray diffraction, electron microscopy, and magnetometer techniques. Isothermal magnetic field variation of magnetization exhibits field hysteresis in bulk Ni51Mn33.4In15.6 alloy across the martensitic transition which significantly lessened in the nanoparticles. The magnetocaloric effects of the bulk and nanoparticle samples were measured both with direct method, through our state of the art direct test bed apparatus with controllability over the applied fields and temperatures, as well as an indirect method through Maxwell and thermodynamic equations. In direct measurements, nanoparticle sample's critical temperature decreased by 6 K, but its magnetocaloric effect enhanced by 17% over the bulk counterpart. Additionally, when comparing the direct and indirect magnetocaloric curves, the direct method showed 14% less adiabatic temperature change in the bulk and 5% less adiabatic temperature change in the nanostructured sample.

  10. Automated spectro-goniometer: A spherical robot for the field measurement of the directional reflectance of snow

    International Nuclear Information System (INIS)

    Painter, Thomas H.; Paden, Brad; Dozier, Jeff

    2003-01-01

    We describe an automated spectro-goniometer (ASG) that rapidly measures the spectral hemispherical-directional reflectance factor (HDRF) of snow in the field across the wavelength range 0.4≤λ≤2.5 μm. Few measurements of snow's HDRF exist in the literature, in part caused by a lack of a portable instrument capable of rapid, repeatable sampling. The ASG is a two-link spherical robot coupled to a field spectroradiometer. The ASG is the first revolute joint and first automated field goniometer for use over snow and other smooth surfaces. It is light enough (∼50 kg) to be portable in a sled by an individual. The ASG samples the HDRF at arbitrary angular resolution and 0.5 Hz sampling rate. The arm attaches to the fixed-point frame 0.65 m above the surface. With vertical and oblique axes, the ASG places the sensor of the field spectroradiometer at any point on the hemisphere above a snow target. In standard usage, the ASG has the sun as the illumination source to facilitate in situ measurements over fragile surfaces not easily transported to the laboratory and to facilitate simultaneous illumination conditions for validation and calibration of satellite retrievals. The kinematics of the ASG is derived using Rodrigues' formula applied to the 2 degree-of-freedom arm. We describe the inverse kinematics for the ASG and solve the inverse problem from a given view angle to the necessary rotation about each axis. Its two-dimensional hemispheric sampling space facilitates the measurement of spectral reflectance from snow and other relatively smooth surfaces into any direction. The measurements will be used to validate radiative transfer model results of directional reflectance and to validate/calibrate directional satellite measurements of reflectance from these smooth surfaces

  11. Measurement of direct CP violation in the NA48 experiment; Mise en evidence de la violation directe de CP par l'experience NA48

    Energy Technology Data Exchange (ETDEWEB)

    Formica, A

    2001-10-01

    The 2 first chapters of this thesis are dedicated to the theoretical and experimental aspects of CP violation. The NA48 experiment is a third generation experiment like KTeV, NA48 has been designed to collect data concerning the simultaneous detection of the 4 decay modes: K{sub L,S} {yields} {pi}{pi} and to provide the measurement of the parameter of direct CP violation with an uncertainty nearing 2*10{sup -4}. The third chapter describes the experimental equipment of NA48 in CERN: the production of K{sub L} and K{sub S} beams, the tagging system, the detection system for K {yields} {pi}{sup +}{pi}{sup -}, the detection system for K {yields} {pi}{sup 0}{pi}{sup 0}, the data acquisition system, and the trigger system. Chapter 4 is dedicated to the selection and identification of events. Chapter 5 deals with specific problems concerning the detection of {pi}{sup +}{pi}{sup -}, it means: the dead time in the triggering system, the overflow of the chamber reading system and the inefficiency of shift chambers. Chapter 6 lists the different corrections and systematic errors concerning the double ratio R, and gives the following result: Re({epsilon}'/{epsilon}=(14.4{+-}2.6)*10{sup -4}) which is by itself, for the first time, an evidence of direct violation. (A.C.)

  12. Advances in Methane Isotope Measurements via Direct Absorption Spectroscopy with Applications to Oil and Gas Source Characterization

    Science.gov (United States)

    Yacovitch, T. I.; Herndon, S. C.; Roscioli, J. R.; Petron, G.; Shorter, J. H.; Jervis, D.; McManus, J. B.; Nelson, D. D.; Zahniser, M. S.; Kolb, C. E., Jr.

    2015-12-01

    Instrumental developments in the measurement of multiple isotopes of methane (12CH4, 13CH4 and 12CH3D) are presented. A first generation 8-micron instrument quantifies 12CH4 and 13CH4 at a 1-second rate via tunable infrared direct absorption spectroscopy (TILDAS). A second generation instrument uses two 3-micron intraband cascade lasers in an Aerodyne dual laser chassis for simultaneous measurement of 12CH4, 13CH4 and 12CH3D. Sensitivity and noise performance improvements are examined. The isotopic signature of methane provides valuable information for emission source identification of this greenhouse gas. A first generation spectrometer has been deployed in the field on a mobile laboratory along with a sophisticated 4-tank calibration system. Calibrations are done on an agressive schedule, allowing for the correction of measured isotope ratios to an absolute isotope scale. Distinct isotopic signatures are found for a number of emission sources in the Denver-Julesburg Basin: oil and gas gathering stations, compressor stations and processing plants; a municipal landfill, and dairy/cattle operations. The isotopic signatures are compared with measured ethane/methane ratios. These direct absorption measurements have larger uncertainties than samples measured via gas chromatography-mass spectrometry, but have several advantages over canister sampling methods: individual sources of short duration are easier to isolate; calibrated isotope ratio results are available immediately; replicate measurements on a single source are easily performed; and the number of sources sampled is not limited by canister availability and processing time.

  13. Metrological issues related to BRDF measurements around the specular direction in the particular case of glossy surfaces

    Science.gov (United States)

    Obein, Gaël.; Audenaert, Jan; Ged, Guillaume; Leloup, Frédéric B.

    2015-03-01

    Among the complete bidirectional reflectance distribution function (BRDF), visual gloss is principally related to physical reflection characteristics located around the specular reflection direction. This particular part of the BRDF is usually referred to as the specular peak. A good starting point for the physical description of gloss could be to measure the reflection properties around this specular peak. Unfortunately, such a characterization is not trivial, since for glossy surfaces the width of the specular peak can become very narrow (typically a full width at half maximum inferior to 0.5° is encountered). In result, new BRDF measurement devices with a very small solid angle of detection are being introduced. Yet, differences in the optical design of BRDF measurement instruments engender different measurement results for the same specimen, complicating direct comparison of the measurement results. This issue is addressed in this paper. By way of example, BRDF measurement results of two samples, one being matte and the other one glossy, obtained by use of two high level goniospectrophotometers with a different optical design, are described. Important discrepancies in the results of the glossy sample are discussed. Finally, luminance maps obtained from renderings with the acquired BRDF data are presented, exemplifying the large visual differences that might be obtained. This stresses the metrological aspects that must be known for using BRDF data. Indeed, the comprehension of parameters affecting the measurement results is an inevitable step towards progress in the metrology of surface gloss, and thus towards a better metrology of appearance in general.

  14. Direct method for measuring and witnessing quantum entanglement of arbitrary two-qubit states through Hong-Ou-Mandel interference

    Science.gov (United States)

    Bartkiewicz, Karol; Chimczak, Grzegorz; Lemr, Karel

    2017-02-01

    We describe a direct method for experimental determination of the negativity of an arbitrary two-qubit state with 11 measurements performed on multiple copies of the two-qubit system. Our method is based on the experimentally accessible sequences of singlet projections performed on up to four qubit pairs. In particular, our method permits the application of the Peres-Horodecki separability criterion to an arbitrary two-qubit state. We explicitly demonstrate that measuring entanglement in terms of negativity requires three measurements more than detecting two-qubit entanglement. The reported minimal set of interferometric measurements provides a complete description of bipartite quantum entanglement in terms of two-photon interference. This set is smaller than the set of 15 measurements needed to perform a complete quantum state tomography of an arbitrary two-qubit system. Finally, we demonstrate that the set of nine Makhlin's invariants needed to express the negativity can be measured by performing 13 multicopy projections. We demonstrate both that these invariants are a useful theoretical concept for designing specialized quantum interferometers and that their direct measurement within the framework of linear optics does not require performing complete quantum state tomography.

  15. Measuring the CO2 shadow price for wastewater treatment: A directional distance function approach

    International Nuclear Information System (INIS)

    Molinos-Senante, María; Hanley, Nick; Sala-Garrido, Ramón

    2015-01-01

    Highlights: • The shadow price of CO 2 informs about the marginal abatement cost of this pollutant. • It is estimated the shadow price of CO 2 for wastewater treatment plants. • The shadow prices depend on the setting of the directional vectors of the distance function. • Sewage sludge treatment technology affects the CO 2 shadow price. - Abstract: The estimation of the value of carbon emissions has become a major research and policy topic since the establishment of the Kyoto Protocol. The shadow price of CO 2 provides information about the marginal abatement cost of this pollutant. It is an essential element in guiding environmental policy issues, since the CO 2 shadow price can be used when fixing carbon tax rates, in environmental cost-benefit analysis and in ascertaining an initial market price for a trading system. The water industry could play an important role in the reduction of greenhouse gas (GHG) emissions. This paper estimates the shadow price of CO 2 for a sample of wastewater treatment plants (WWTPs), using a parametric quadratic directional distance function. Following this, in a sensitivity analysis, the paper evaluates the impact of different settings of directional vectors on the shadow prices. Applying the Mann–Whitney and Kruskal–Wallis non-parametric tests, factors affecting CO 2 prices are investigated. The variation of CO 2 shadow prices across the WWTPs evaluated argues in favour of a market-based approach to CO 2 mitigation as opposed to command-and-control regulation. The paper argues that the estimation of the shadow price of CO 2 for non-power enterprises can provide incentives for reducing GHG emissions

  16. Quantitative assay for the measurement of immune responses directed against the human placenta

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M; Sutcliffe, R G [Glasgow Univ. (UK)

    1982-02-12

    A quantitative in vitro immune assay based on the classical chromium release assay has been developed to detect immune responses directed against alien antigens expressed by the developing foetus and present on the maternal-facing surface of the human placenta. A plasma membrane fraction from the surface of the placenta was prepared and the vesicles thus formed were radiolabelled with /sup 51/Cr. The /sup 51/Cr-labelled vesicles, by various criteria, were found to be suitable for use as targets in a release assay. Further, by means of experimentally immunised animals, the target membranes were shown to be capable of detecting both cellular and humoral anti-placental activity.

  17. Direct measurements of particle flux along gap sides in castellated plasma facing component in COMPASS

    International Nuclear Information System (INIS)

    Dejarnac, Renaud; Dimitrova, Miglena; Komm, Michael; Schweer, Bernd; Terra, Alexis; Martin, Aurelien; Boizante, Gontran; Gunn, James P.; Panek, Radomir

    2014-01-01

    Highlights: •We designed a probe to measure plasma deposition into gaps during tokamak discharges. •Isat profiles are measured on both side of the gap for different gap orientations. •Ion current is measured at the bottom of the gap in the toroidal orientation. •Kinetic simulations reproduce well experimental profiles qualitatively. -- Abstract: In this paper, we report results of a dedicated experiment that gives the plasma penetration profiles inside a gap of a tokamak castellated plasma-facing component. A specially designed probe that recreates a gap between two tiles has been built for the purpose of this study. It allows to measure ion saturation profiles along the 2 sides and at the bottom of the gap for both poloidal and toroidal orientations. The novelty of such experiment is the real time measurement of the plasma flux inside the gap during a tokamak D-shaped discharge compared to previous experimental studies which were mainly post-mortem. This experiment was performed in the COMPASS tokamak and results are compared with particle-in-cell simulations. The plasma deposition is found to be asymmetric in both orientations with a stronger effect in poloidal gaps. The Larmor radius of the incoming ions plays a role in the plasma penetration only in poloidal gaps but seems to have little impact in toroidal gaps. Profiles are qualitatively well reproduced by simulations. Ion current is recorded at the bottom of a toroidal gap under certain conditions

  18. Direct comparison of AFM and SEM measurements on the same set of nanoparticles

    International Nuclear Information System (INIS)

    Delvallée, A; Feltin, N; Ducourtieux, S; Trabelsi, M; Hochepied, J F

    2015-01-01

    This article is the first step in the development of a hybrid metrology combining AFM and SEM techniques for measuring the dimensions of a nanoparticle population in 3D space (X,Y,Z). This method exploits the strengths of each technique on the same set of nanoparticles. AFM is used for measuring the nanoparticle height and the measurements along X and Y axes are deduced from SEM images. A sampling method is proposed in order to obtain the best deposition conditions of SiO 2 and gold nanoparticles on mica or silicon substrates. Only the isolated nanoparticles are taken into account in the histogram of size distribution. Moreover, a semi-automatic Matlab routine has also been developed to process the AFM and SEM images, measure and count the nanoparticles. This routine allows the user to exclusively select the isolated nanoparticles through a control interface. The measurements have been performed on spherical-like nanoparticles to test the method by comparing the results obtained with both techniques. (paper)

  19. Measurements of the large-scale direct-current Earth potential and possible implications for the geomagnetic dynamo.

    Science.gov (United States)

    1985-07-05

    The magnitude of the large-scale direct-current earth potential was measured on a section of a recently laid transatlantic telecommunications cable. Analysis of the data acquired on the 4476-kilometer cable yielded a mean direct-current potential drop of less than about 0.072 +/- 0.050 millivolts per kilometer. Interpreted in terms of a generation of the potential by the earth's geodynamo, such a small value of the mean potential implies that the toroidal and poloidal magnetic fields of the dynamo are approximately equal at the core-mantle boundary.

  20. Limits on the production of large transverse momentum direct photons deduced from the measurement of low-mass electron pairs

    International Nuclear Information System (INIS)

    Cobb, J.H.; Iwata, S.; Palmer, R.B.; Rahm, D.C.; Rehak, P.; Stumer, I.; Fabjan, C.W.; Fowler, E.; Mannelli, I.; Mouzourakis, P.; Nakamura, K.; Nappi, A.; Willis, W.J.; Goldberg, M.; Horwitz, N.; Moneti, G.C.; Lankford, A.J.; Kourkoumelis, C.

    1978-01-01

    The hadronic production of electron pairs with masses between 200 and 500 MeV and large transverse momentum has been measured at the CERN Intersecting Storage Rings (ISR). The expected relation between low-mass electron pairs and real photons is used to determine the direct hadronic production of photons. Contrary to indications from some previous experiments, the observed spectrum is consistent with expectations from the decay of known mesons, and leads to a value for the ratio of direct photons to π 0 of γ/π 0 =(0.55+-0.92)% for 2 = 55 GeV. (Auth.)

  1. Direct Measurement of Nuclear Dependence of Charged Current Quasielasticlike Neutrino Interactions Using MINERvA

    Science.gov (United States)

    Betancourt, M.; Ghosh, A.; Walton, T.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Bodek, A.; Bravar, A.; Cai, T.; Martinez Caicedo, D. A.; Carneiro, M. F.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Harris, D. A.; Higuera, A.; Hurtado, K.; Kiveni, M.; Kleykamp, J.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman, Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Sobczyk, J. T.; Solano Salinas, C. J.; Sánchez Falero, S.; Valencia, E.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; Minerva Collaboration

    2017-08-01

    Charged-current νμ interactions on carbon, iron, and lead with a final state hadronic system of one or more protons with zero mesons are used to investigate the influence of the nuclear environment on quasielasticlike interactions. The transferred four-momentum squared to the target nucleus, Q2, is reconstructed based on the kinematics of the leading proton, and differential cross sections versus Q2 and the cross-section ratios of iron, lead, and carbon to scintillator are measured for the first time in a single experiment. The measurements show a dependence on the atomic number. While the quasielasticlike scattering on carbon is compatible with predictions, the trends exhibited by scattering on iron and lead favor a prediction with intranuclear rescattering of hadrons accounted for by a conventional particle cascade treatment. These measurements help discriminate between different models of both initial state nucleons and final state interactions used in the neutrino oscillation experiments.

  2. Measurements of the low-energy gamma-ray continuum emission from the Galactic Center direction

    International Nuclear Information System (INIS)

    Jardim, M.V.A.; Martin, I.M.; Jardim, J.O.D.

    1982-07-01

    The measurement of the gamma-ray continuum emission from the Galactic Center (GC) can provide us information about the physical processes taking place there at the site of emission. Using the data obtained with a balloon-borne gamma-ray telescope to measure gamma-rays in the energy interval between 0,3 and 3 MeV, which was launched on March 28, 1980 from Cachoeira Paulista (SP), we calculeted two points for the continuum spectrum in the range between 0,34 and 0,67 MeV. The points are related to the GC emission radiated in the longitude interval - 31 0 0 . The measurements are compatible with the observations in 1969 and 1972 by Haymes et alii and Johnson, respectively. The power law spectrum suggests that the main component for the gamma-ray continuum emission below 10 MeV is dominated by the bremsstrahlung due to relativistic electrons. (Author) [pt

  3. Direct and CT measurements of canals and foramina of the skull base

    International Nuclear Information System (INIS)

    Berlis, A.; Schumacher, M.; Putz, R.

    1992-01-01

    This investigation is based on measurements of 60 macerated adult European skulls from the Alexander-Ecker Collection at the Anatomy Department of the University of Freiburg. Computer tomographical (CT) and anatomical measurements were compared to assess the accuracy of the CT representation of osseous structures. Nine structures were examined: the optic canal, superior orbital fissure, foramen rotundum, foramen ovale, foramen spinosum,foramen Vesalii (venosum), carotid canal, internal auditory canal and hypoglossal canal. Results show a good and even excellent correlation if the cranial opening is approximately at a right angle to the scanline. For this reason, the results of the coronal examination of the internal auditory canal are less satisfactory, and the coronal and axial measurements of the hypoglossal canal show only a moderately good correlation. (author)

  4. An Applied Anatomical Study of the Ethmoidal Arteries: Computed Tomographic and Direct Measurements in Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Karnov, Kirstine; Clemmensen, Anne

    2018-01-01

    and posterior ethmoidal foramina (AEF and PEF), optic canal (OC), respectively. However, the large interindividual variation of distances renders absolute values less applicable in a clinical setting. Preoperative measurements on CT images may provide more precise distances than absolute rules and thus lead...... to safer orbital surgery. The authors hypothesize that the distances to the ethmoidal arteries and the length of the medial wall are positively correlated and that measurements of the distances from the posterior lacrimal crest (PLC) on CT images are feasible with a low intra-and interobserver variability...... anterior landmarks to the arteries were positively correlated with the length of the medial wall. Measurements of the distances from the PLC to the ethmoidal arteries on CT images were feasible with a low intra-and interobserver variability. In conclusion, iatrogenic damage to the ethmoidal arteries...

  5. Direct measurement of Cu surface self-diffusion on a checked surface

    International Nuclear Information System (INIS)

    Cousty, Jacques; Peix, Roger; Perraillon, Bernard.

    1976-01-01

    A radiotracer technique ( 64 Cu) was developed to measure surface diffusion on copper surfaces of total impurity concentration not exceeding some 10 -3 monolayers. The apparatus used consists of a slow electron diffraction device, an Auger analysis spectrometer (CMA), an ion gun and an evaporation device assembled in an ultra-vacuum chamber holding a residual pressure below 10 -10 Torr. A sample handler enables the surface studied to be positioned in front of each of these instruments. During the diffusion treatment the chemical composition of the surface is checked intermittently, and afterwards the spread of the deposit is measured outside the ultravacuum chamber. Slices several microns thick are removed and dissolved separately in dishes containing HNO 3 . The activity is then measured with a flow counter [fr

  6. Estimating air emissions from a remediation of a petroleum sump using direct measurement and modeling

    International Nuclear Information System (INIS)

    Schmidt, C.E.

    1991-01-01

    A technical approach was developed for the remediation of a petroleum sump near a residential neighborhood. The approach evolved around sludge handling/in-situ solidification and on-site disposal. As part of the development of the engineering approach, a field investigation and modeling program was conducted to predict air emissions from the proposed remediation. Field measurements using the EPA recommended surface isolation flux chamber were conducted to represent each major activity or air exposure involving waste at the site. Air emissions from freshly disturbed petroleum waste, along with engineering estimates were used to predict emissions from each phase of the engineering approach. This paper presents the remedial approach and the measurement/modeling technologies used to predict air toxic emissions from the remediation. Emphasis will be placed on the measurement approaches used in obtaining the emission rate data and the assumptions used in the modeling to estimate emissions from engineering scenarios

  7. Off-axis ultraviolet-written thin-core fiber Bragg grating for directional bending measurements

    Science.gov (United States)

    Zhang, Lisong; Qiao, Xueguang; Liu, Qinpeng; Shao, Min; Jiang, Youhua; Huang, Dong

    2018-03-01

    A directional bending sensor based on thin-core fiber Bragg grating is proposed and demonstrated experimentally. It is inscribed by off-center technique and exposed by 193 nm ArF excimer laser through a phase mask. A series of cladding modes are excited and their intensities are enhanced to about 10 dB. The formation mechanism of those cladding modes is discussed and analyzed. The intensities of these cladding mode resonances is detected for bending and direction with maximum sensitivity 1.93 dB/m1 at 0° to - 1 . 95 dB/m1 at 180°under the curvature varied from 0 m-1to 2.5 m-1. The sensitivity of surrounding temperature is 11.3pm/°C ranging from 25 °C to 60 °C. This all-fiber structure has a great advantage for fiber orientation identification sensor with more convenient manufacture and needless de-localize FBGs.

  8. Direct mass measurements in the light neutron-rich region using a combined energy and time-of-flight technique

    International Nuclear Information System (INIS)

    Pillai, C.; Swenson, L.W.; Vieira, D.J.; Butler, G.W.; Wouters, J.M.; Rokni, S.H.; Vaziri, K.; Remsberg, L.P.

    1985-01-01

    This experiment has demonstrated that direct mass measurements can be performed (albeit of low precision in this first attempt) using the M proportional to ET 2 method. This technique has the advantage that many particle-bound nuclei, produced in fragmentation reactions can be measured simultaneously, independent of their N or Z. The main disadvantage of this approach is that both energy and time-of-flight must be measured precisely on an absolute scale. Although some mass walk with N and Z was observed in this experiment, these uncertainties were largely removed by extrapolating the smooth dependence observed for known nuclei which lie closer to the valley of β-stability. Mass measurements for several neutron-rich light nuclei ranging from 17 C to 26 Ne have been performed. In all cases these measurements agree with the latest mass compilation of Wapstra and Audi. The masses of 20 N and 24 F have been determined for the first time

  9. Benchmarking of 3D space charge codes using direct phase space measurements from photoemission high voltage dc gun

    Directory of Open Access Journals (Sweden)

    Ivan V. Bazarov

    2008-10-01

    Full Text Available We present a comparison between space charge calculations and direct measurements of the transverse phase space of space charge dominated electron bunches from a high voltage dc photoemission gun followed by an emittance compensation solenoid magnet. The measurements were performed using a double-slit emittance measurement system over a range of bunch charge and solenoid current values. The data are compared with detailed simulations using the 3D space charge codes GPT and Parmela3D. The initial particle distributions were generated from measured transverse and temporal laser beam profiles at the photocathode. The beam brightness as a function of beam fraction is calculated for the measured phase space maps and found to approach within a factor of 2 the theoretical maximum set by the thermal energy and the accelerating field at the photocathode.

  10. The direct measurement of the heteronuclear chemical shifts relative to tetramethylsilane

    International Nuclear Information System (INIS)

    Moritz, A.G.

    1988-12-01

    The measurement of heteronuclear chemical shifts using absolute frequencies of the heteronucleus and the 1 H resonance of tetramethylsilane has been examined. This method avoids the problems associated with external standards and gives results which can be obtained quickly and with high precision. The method has a number of advantages in the accurate measurement of chemical shifts, as for example 31 P in chemical warfare agents and related chemicals and allows multinuclear data to be obtained without dynamic range or potential interference problems. 15 refs., 4 tabs

  11. Direct measurement of electron density in microdischarge at atmospheric pressure by Stark broadening

    International Nuclear Information System (INIS)

    Dong Lifang; Ran Junxia; Mao Zhiguo

    2005-01-01

    We present a method and results for measurement of electron density in atmospheric-pressure dielectric barrier discharge. The electron density of microdischarge in atmospheric pressure argon is measured by using the spectral line profile method. The asymmetrical deconvolution is used to obtain Stark broadening. The results show that the electron density in single filamentary microdischarge at atmospheric pressure argon is 3.05x10 15 cm -3 if the electron temperature is 10,000 K. The result is in good agreement with the simulation. The electron density in dielectric barrier discharge increases with the increase of applied voltage

  12. Measurement of magnetic fields in the direct proximity of power line conductors

    International Nuclear Information System (INIS)

    Mamishev, A.V.; Russell, B.D.

    1995-01-01

    Modeling and managing of power frequency magnetic fields requires verification of theory with actual measurements. Measurements only at ground level are not always sufficient for comprehensive studies. The technique and the results of three-dimensional mapping of the power frequency magnetic fields high above ground level are presented in this paper. Comparative calculations illustrate relevance and approximations of the existing theoretical approach to field modeling. The influence of harmonics on the elliptical rotation of the magnetic field vector is illustrated. The possibility of use of the magnetic fields for the power line proximity detection is discussed

  13. Direct measurement of the impulse in a magnetic thrust chamber system for laser fusion rocket

    Energy Technology Data Exchange (ETDEWEB)

    Maeno, Akihiro; Yamamoto, Naoji; Nakashima, Hideki [Interdisciplinary Graduate School of Engineering Science, Kyushu University, 6-1 Kasuga-kouen, Kasuga, Fukuoka 816-8580 (Japan); Fujioka, Shinsuke; Johzaki, Tomoyuki [Institute of Laser Engineering, Osaka University, Suita, Osaka 565-087 (Japan); Mori, Yoshitaka [Graduate School for the Creation of New Photonics Industries, Hamamatsu, Shizuoka 431-1202 (Japan); Sunahara, Atsushi [Institute for Laser Technology, Suita, Osaka 565-087 (Japan)

    2011-08-15

    An experiment is conducted to measure an impulse for demonstrating a magnetic thrust chamber system for laser fusion rocket. The impulse is produced by the interaction between plasma and magnetic field. In the experiment, the system consists of plasma and neodymium permanent magnets. The plasma is created by a single-beam laser aiming at a polystyrene spherical target. The impulse is 1.5 to 2.2 {mu}Ns by means of a pendulum thrust stand, when the laser energy is 0.7 J. Without magnetic field, the measured impulse is found to be zero. These results indicate that the system for generating impulse is working.

  14. Real-time measurement of plutonium in air by direct-inlet surface ionization mass spectrometry. Status report

    International Nuclear Information System (INIS)

    Stoffels, J.J.

    1980-04-01

    A new technique is being developed for monitoring low-level airborne plutonium on a real-time basis. The technique is based on surface ionization mass spectrometry of airborne particles. It will be capable of measuring plutonium concentrations below the maximum permissible concentration (MPC) level. A complete mass spectrometer was designed and constructed for this purpose. Major components which were developed and made operational for the instrument include an efficient inlet for directly sampling particles in air, a wide dynamic range ion detector and a minicomputer-based ion-burst measurement system. Calibration of the direct-inlet mass spectrometer (DIMS) was initiated to establish the instrument's response to plutonium dioxide as a function of concentration and particle size. This work revealed an important problem - bouncing of particles upon impact with the ionizing filament. Particle bounce results in a significant loss of measurement sensitivity. The feasibility of using an oven ionizer to overcome the particle bounce problem has been demonstrated. A rhenium oven ionizer was designed and constructed for the purpose of trapping particles which enter via the direct inlet. High-speed particles were trapped in the oven yielding a measurement sensitivity comparable to that for particles which are preloaded. Development of the Pu DIMS can now be completed by optimizing the oven design and calibrating the instrument's performance with UO 2 and CeO 2 particles as analogs to PuO 2 particles

  15. Thoron and radon progeny concentration measurements using direct progeny sensors in HLNRAs of Kerala

    International Nuclear Information System (INIS)

    Mishra, R.; Prajith, R.; Gole, A.C.; Kanse, S.D.; Chougaonkar, M.P.; Sapra, B.K.; Mayya, Y.S.; Jayalekshmi, P.; Nair, Raghu Ram K.

    2010-01-01

    Passive Progeny Dosimeters (PPDs) were deployed in 500 houses in 3 villages namely Allapad, Chavara and Neendakara villages of Karunagapally Taluk of Kollam district of Kerala. Each PPD unit is a combination of a DTPS and a DRPS placed side-by-side for time integrated thoron and radon progeny concentration estimation respectively. The PPDs were suspended vertically in the rooms, such that the nearest distance from any wall or surface was at least 30 cm. These are, as of now, being exposed for a period of 3 months, after which they will be retrieved and analysed by chemical etching and track counting. Simultaneously, external gamma radiation measurements have also been made using a survey meter; these showed a variation from 13 to 118 μR/h in indoors and 21 to 213 μR/h in the outdoor environments. Spot measurements of thoron progeny concentrations were also made in 7 selected houses using the conventional grab filter-paper sampling technique at a flow-rate of 21 min -1 for 30 minutes, followed by alpha counting. The average thoron progeny concentration was found to be 2.0 ± 0.7 Bq m -3 . In the outdoor environment, filter-paper sampling was carried out for 2 hours at 21 min -1 and the thoron progeny concentration was measured as 2.96 Bq m -3 . To corroborate these measurements, a flow mode integrated sampler which uses the DTPS and DRPS elements was used

  16. Direct measurement of α2F in normal metals using point-contacts: noble metals

    International Nuclear Information System (INIS)

    Jansen, A.G.M.; Mueller, F.M.; Wyder, P.

    1976-01-01

    A new technique of forming tiny point junctions, first discussed by Sharvin, is described. By measuring the second derivative of voltage with respect to current, using techniques similar to tunnel junction spectroscopy, structure is found which is consistent with bulk phonon densities of states derived from neutron scattering. The same results were reported at LT 14 by Yanson using a shorted film technique

  17. Fire metrology: Current and future directions in physics-based measurements

    Science.gov (United States)

    Robert L. Kremens; Alistair M.S. Smith; Matthew B. Dickinson

    2010-01-01

    The robust evaluation of fire impacts on the biota, soil, and atmosphere requires measurement and analysis methods that can characterize combustion processes across a range of temporal and spatial scales. Numerous challenges are apparent in the literature. These challenges have led to novel research to quantify the 1) structure and heterogeneity of the pre-fire...

  18. Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer

    International Nuclear Information System (INIS)

    Dilling, J.; Audi, G.; Beck, D.; Bollen, G.; Henry, S.; Herfurth, F.; Kellerbauer, A.; Kluge, H.-J.; Lunney, D.; Moore, R.B.; Scheidenberger, C.; Schwarz, S.; Sikler, G.; Szerypo, J.

    2002-01-01

    The masses of Xe isotopes with 124≥A≥114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm∼12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found

  19. Possibilistic Belief Functions Generated by Direct Products of Single Possibilistic Measures

    Czech Academy of Sciences Publication Activity Database

    Kramosil, Ivan

    1999-01-01

    Roč. 9, č. 6 (1999), s. 517-525 ISSN 1210-0552 R&D Projects: GA AV ČR IAA1030803 Institutional research plan: AV0Z1030915 Keywords : belief functions * belief revision * Dempster combination rule * possibilistic measures * possibilistic belief functions Subject RIV: BA - General Mathematics

  20. Fast and direct measurements of the electrical properties of graphene using micro four-point probes

    DEFF Research Database (Denmark)

    Klarskov, Mikkel Buster; Dam, Henrik Friis; Petersen, Dirch Hjorth

    2011-01-01

    . Measurements are performed in ambient, vacuum and controlled environmental conditions using an environmental scanning electron microscope (SEM). The results are comparable to previous results for microcleaved graphene on silicon dioxide (SiO2). We observe a pronounced hysteresis of the charge neutrality point...

  1. The Major Field Test in Business: A Direct Measure of Learning in Common Business Disciplines

    Science.gov (United States)

    Simmons, Susan A.; Jones, Wesley M., Jr; Bolt, Cynthia E.

    2015-01-01

    Assurance of learning and its assessment are critical focal points in collegiate schools of business as programs strive to achieve or maintain Association to Advance Collegiate Schools of Business accreditation. Prior research suggests that student learning in business core disciplines can be measured by the Educational Testing Service Major Field…

  2. Development of a direct observation Measure of Environmental Qualities of Activity Settings.

    Science.gov (United States)

    King, Gillian; Rigby, Patty; Batorowicz, Beata; McMain-Klein, Margot; Petrenchik, Theresa; Thompson, Laura; Gibson, Michelle

    2014-08-01

    The aim of this study was to develop an observer-rated measure of aesthetic, physical, social, and opportunity-related qualities of leisure activity settings for young people (with or without disabilities). Eighty questionnaires were completed by sets of raters who independently rated 22 community/home activity settings. The scales of the 32-item Measure of Environmental Qualities of Activity Settings (MEQAS; Opportunities for Social Activities, Opportunities for Physical Activities, Pleasant Physical Environment, Opportunities for Choice, Opportunities for Personal Growth, and Opportunities to Interact with Adults) were determined using principal components analyses. Test-retest reliability was determined for eight activity settings, rated twice (4-6wk interval) by a trained rater. The factor structure accounted for 80% of the variance. The Kaiser-Meyer-Olkin Measure of Sampling Adequacy was 0.73. Cronbach's alphas for the scales ranged from 0.76 to 0.96, and interrater reliabilities (ICCs) ranged from 0.60 to 0.93. Test-retest reliabilities ranged from 0.70 to 0.90. Results suggest that the MEQAS has a sound factor structure and preliminary evidence of internal consistency, interrater, and test-retest reliability. The MEQAS is the first observer-completed measure of environmental qualities of activity settings. The MEQAS allows researchers to assess comprehensively qualities and affordances of activity settings, and can be used to design and assess environmental qualities of programs for young people. © 2014 Mac Keith Press.

  3. Measurements of area and the (island) species-area relationship: new directions for an old pattern

    DEFF Research Database (Denmark)

    Triantis, K.A.; Nogues-Bravo, D.; Hortal, J.

    2008-01-01

    show that increasing the accuracy of the estimation of area has negligible impact on the fit and form of the species-area relationship, even though our analyses included some of the most topographically diverse island groups in the world. In addition, we show that the inclusion of general measurements...

  4. Direct Measurement of Power Dissipated by Monte Carlo Simulations on CPU and FPGA Platforms

    DEFF Research Database (Denmark)

    Albicocco, Pietro; Papini, Davide; Nannarelli, Alberto

    In this technical report, we describe how power dissipation measurements on different computing platforms (a desktop computer and an FPGA board) are performed by using a Hall effectbased current sensor. The chosen application is a Monte Carlo simulation for European option pricing which is a popu...

  5. Direct inversion of circulation and mixing from tracer measurements – Part 1: Method

    Directory of Open Access Journals (Sweden)

    T. von Clarmann

    2016-11-01

    Full Text Available From a series of zonal mean global stratospheric tracer measurements sampled in altitude vs. latitude, circulation and mixing patterns are inferred by the inverse solution of the continuity equation. As a first step, the continuity equation is written as a tendency equation, which is numerically integrated over time to predict a later atmospheric state, i.e., mixing ratio and air density. The integration is formally performed by the multiplication of the initially measured atmospheric state vector by a linear prediction operator. Further, the derivative of the predicted atmospheric state with respect to the wind vector components and mixing coefficients is used to find the most likely wind vector components and mixing coefficients which minimize the residual between the predicted atmospheric state and the later measurement of the atmospheric state. Unless multiple tracers are used, this inversion problem is under-determined, and dispersive behavior of the prediction further destabilizes the inversion. Both these problems are addressed by regularization. For this purpose, a first-order smoothness constraint has been chosen. The usefulness of this method is demonstrated by application to various tracer measurements recorded with the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS. This method aims at a diagnosis of the Brewer–Dobson circulation without involving the concept of the mean age of stratospheric air, and related problems like the stratospheric tape recorder, or intrusions of mesospheric air into the stratosphere.

  6. Modeling Method for Increased Precision and Scope of Directly Measurable Fluxes at a Genome-Scale

    DEFF Research Database (Denmark)

    McCloskey, Douglas; Young, Jamey D.; Xu, Sibei

    2016-01-01

    pathways of traditional MFA models and also covers the additional pathways of purine, pyrimidine, isoprenoid, methionine, riboflavin, coenzyme A, and folate, as well as other biosynthetic pathways. When evaluating the iDM2014 using a set of measured intracellular intermediate and cofactor mass isotopomer...

  7. Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

    Science.gov (United States)

    Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther

    2018-04-01

    A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.

  8. A new method for the measurement of two-phase mass flow rate using average bi-directional flow tube

    International Nuclear Information System (INIS)

    Yoon, B. J.; Uh, D. J.; Kang, K. H.; Song, C. H.; Paek, W. P.

    2004-01-01

    Average bi-directional flow tube was suggested to apply in the air/steam-water flow condition. Its working principle is similar with Pitot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of pitot tube when it is used in the depressurization condition. The suggested flow tube was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. In the test, the pressure drop across the average bi-directional flow tube, system pressure and average void fraction were measured on the measuring plane. In the test, fluid temperature and injected mass flow rates of air and water phases were also measured by a RTD and two coriolis flow meters, respectively. To calculate the phasic mass flow rates : from the measured differential pressure and void fraction, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within 10% error of measured data

  9. Human epithelial cells increase their rigidity with ageing in vitro: direct measurements

    International Nuclear Information System (INIS)

    Berdyyeva, Tamara K; Woodworth, Craig D; Sokolov, Igor

    2005-01-01

    The decrease in elasticity of epithelial tissues with ageing contributes to many human diseases. This change was previously attributed to increased crosslinking of extracellular matrix proteins. Here we show that individual human epithelial cells also become significantly more rigid during ageing in vitro. Using atomic force microscopy (AFM), we found that the Young's modulus of viable cells was consistently increased two- to four-fold in older versus younger cells. Direct visualization of the cytoskeleton using a novel method involving the AFM suggested that increased rigidity of ageing cells was due to a higher density of cytoskeletal fibres. Our results identify a unique mechanism that might contribute to the age-related loss of elasticity in epithelial tissues

  10. Direct measurement of the free energy of aging hard sphere colloidal glasses.

    Science.gov (United States)

    Zargar, Rojman; Nienhuis, Bernard; Schall, Peter; Bonn, Daniel

    2013-06-21

    The nature of the glass transition is one of the most important unsolved problems in condensed matter physics. The difference between glasses and liquids is believed to be caused by very large free energy barriers for particle rearrangements; however, so far it has not been possible to confirm this experimentally. We provide the first quantitative determination of the free energy for an aging hard sphere colloidal glass. The determination of the free energy allows for a number of new insights in the glass transition, notably the quantification of the strong spatial and temporal heterogeneity in the free energy. A study of the local minima of the free energy reveals that the observed variations are directly related to the rearrangements of the particles. Our main finding is that the probability of particle rearrangements shows a power law dependence on the free energy changes associated with the rearrangements similar to the Gutenberg-Richter law in seismology.

  11. Information content of sky intensity and polarization measurements at right angles to the solar direction

    Science.gov (United States)

    Holland, A. C.; Thomas, R. W. L.; Pearce, W. A.

    1978-01-01

    The paper presents the results of a Monte Carlo simulation study of the brightness and polarization at right angles to the solar direction both for ground-based observations (looking up) and for satellite-based systems (looking down). Calculations have been made for a solar zenith angle whose cosine was 0.6 and wavelengths ranging from 3500 A to 9500 A. A sensitivity of signatures to total aerosol loading, aerosol particle size distribution and refractive index, and the surface reflectance albedo has been demonstrated. For Lambertian-type surface reflection the albedo effects enter solely through the intensity sensitivity, and very high correlations have been found between the polarization term signatures for the ground-based and satellite-based systems. Potential applications of these results for local albedo predictions and satellite imaging systems recalibrations are discussed.

  12. Direct measurement of nuclear cross-section of astrophysical interest: Results and perspectives

    Science.gov (United States)

    Cavanna, Francesca; Prati, Paolo

    2018-03-01

    Stellar evolution and nucleosynthesis are interconnected by a wide network of nuclear reactions: the study of such connection is usually known as nuclear astrophysics. The main task of this discipline is the determination of nuclear cross-section and hence of the reaction rate in different scenarios, i.e. from the synthesis of a few very light isotopes just after the Big Bang to the heavy element production in the violent explosive end of massive stars. The experimental determination of reaction cross-section at the astrophysical relevant energies is extremely difficult, sometime impossible, due to the Coulomb repulsion between the interacting nuclei which turns out in cross-section values down to the fbar level. To overcome these obstacles, several experimental approaches have been developed and the adopted techniques can be roughly divided into two categories, i.e. direct and indirect methods. In this review paper, the general problem of nuclear astrophysics is introduced and discussed from the point of view of experimental approach. We focus on direct methods and in particular on the features of low-background experiments performed at underground laboratory facilities. The present knowledge of reactions involved in the Big Bang and stellar hydrogen-burning scenarios is discussed as well as the ongoing projects aiming to investigate mainly the helium- and carbon-burning phases. Worldwide, a new generation of experiment in the MeV range is in the design phase or at the very first steps and decisive progresses are expected to come in the next years.

  13. Validation of cosmogenic nuclide production rate scaling factors through direct measurement

    Energy Technology Data Exchange (ETDEWEB)

    Graham, I.J. E-mail: i.graham@gns.cri.nz; Barry, B.J.; Ditchburn, R.G.; Whitehead, N.E

    2000-10-01

    {sup 7}Be produced in water targets by nuclear interactions of cosmic rays has been measured to determine cosmogenic nuclide production rates as a function of altitude (sea level to 2 km) and geomagnetic latitude (20-79 deg. S). Relative intensities of low energy cosmic ray neutrons have at the same time been measured using neutron monitors based on IGY/NM-64 designed to efficiently thermalise ca. 2-30 MeV neutrons. The research is on-going and we present here preliminary data from the past two years. Water target and neutron flux results are in general agreement, and are consistent with the altitude-dependent scaling factors of Lal [Earth Planet. Sci. Lett. 104 (1991) 4241]. Significant differences between the sea level, latitude-dependent neutron flux data and Lal's predictions are possibly related to the response function of the detector.

  14. Validation of cosmogenic nuclide production rate scaling factors through direct measurement

    CERN Document Server

    Graham, I J; Ditchburn, R G; Whitehead, N E

    2000-01-01

    sup 7 Be produced in water targets by nuclear interactions of cosmic rays has been measured to determine cosmogenic nuclide production rates as a function of altitude (sea level to 2 km) and geomagnetic latitude (20-79 deg. S). Relative intensities of low energy cosmic ray neutrons have at the same time been measured using neutron monitors based on IGY/NM-64 designed to efficiently thermalise ca. 2-30 MeV neutrons. The research is on-going and we present here preliminary data from the past two years. Water target and neutron flux results are in general agreement, and are consistent with the altitude-dependent scaling factors of Lal [Earth Planet. Sci. Lett. 104 (1991) 4241]. Significant differences between the sea level, latitude-dependent neutron flux data and Lal's predictions are possibly related to the response function of the detector.

  15. Qweak: First Direct Measurement of the Proton’s Weak Charge

    Directory of Open Access Journals (Sweden)

    Androic D.

    2017-01-01

    Full Text Available The Qweak experiment, which took data at Jefferson Lab in the period 2010 - 2012, will precisely determine the weak charge of the proton by measuring the parity-violating asymmetry in elastic e-p scattering at 1.1 GeV using a longitudinally polarized electron beam and a liquid hydrogen target at a low momentum transfer of Q2 = 0.025 (GeV/c2. The weak charge of the proton is predicted by the Standard Model and any significant deviation would indicate physics beyond the Standard Model. The technical challenges and experimental apparatus for measuring the weak charge of the proton will be discussed, as well as the method of extracting the weak charge of the proton. The results from a small subset of the data, that has been published, will also be presented. Furthermore an update will be given of the current status of the data analysis.

  16. Direct measurement of dose at depth in breast cancer using lithium fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Dawes, P J.D.K.; Aird, E G; Crawshaw, I P

    1988-05-01

    In 23 cases of breast cancer treated conservatively using external beam and interstitial radiotherapy, lithium fluoride thermoluminescent dosimetry has been used to measure the radiation dose received by the breast tissue at depth. Thirty-six investigations were made using a number of lithium fluoride micro-rods for each investigation. Three results could not be analysed because of measurement problems in two and insufficient information in one. Twenty-eight results were obtained at a depth in tissue greater than the build-up zone, 23 of the 28 falling within +- 5% and 27 of the 28 falling within +- 10% of the computer-calculated prescribed dose. Of five results obtained within the build-up zone, two fell within +- 5% and four within +- 10% of the prescribed dose.

  17. Direct measurement of dose at depth in breast cancer using lithium fluoride

    International Nuclear Information System (INIS)

    Dawes, P.J.D.K.; Aird, E.G.; Crawshaw, I.P.

    1988-01-01

    In 23 cases of breast cancer treated conservatively using external beam and interstitial radiotherapy, lithium fluoride thermoluminescent dosimetry has been used to measure the radiation dose received by the breast tissue at depth. Thirty-six investigations were made using a number of lithium fluoride micro-rods for each investigation. Three results could not be analysed because of measurement problems in two and insufficient information in one. Twenty-eight results were obtained at a depth in tissue greater than the build-up zone, 23 of the 28 falling within ± 5% and 27 of the 28 falling within ± 10% of the computer-calculated prescribed dose. Of five results obtained within the build-up zone, two fell within ± 5% and four within ± 10% of the prescribed dose. (author)

  18. Direct measurement of the Rayleigh scattering cross section in various gases

    International Nuclear Information System (INIS)

    Sneep, Maarten; Ubachs, Wim

    2005-01-01

    Using the laser-based technique of cavity ring-down spectroscopy extinction measurements have been performed in various gases straightforwardly resulting in cross sections for Rayleigh scattering. For Ar and N 2 measurements are performed in the range 470-490nm, while for CO 2 cross sections are determined in the wider range 470-570nm. In addition to these gases also for N 2 O, CH 4 , CO, and SF 6 the scattering cross section is determined at 532nm, a wavelength of importance for lidar applications and combustion laser diagnostics. In O 2 the cross section at 532nm is found to depend on pressure due to collision-induced light absorption. The obtained cross sections validate the cross sections for Rayleigh scattering as derived from refractive indices and depolarization ratios through Rayleigh's theory at the few %-level, although somewhat larger discrepancies are found for CO, N 2 O and CH 4

  19. Fluorescence lifetime measurement with confocal endomicroscopy for direct analysis of tissue biochemistry in vivo

    Directory of Open Access Journals (Sweden)

    Youngjae Won

    2016-08-01

    Full Text Available Confocal endomicroscopy is a powerful tool for in vivo real-time imaging at cellular resolution inside a living body without tissue resection. Microscopic fluorescence lifetime measurement can provide information about localized biochemical conditions such as pH and the concentrations of oxygen and calcium. We hypothesized that combining these techniques could assist accurate cancer discrimination by providing both biochemical and morphological information. We designed a dual-mode experimental setup for confocal endomicroscopic imaging and fluorescence lifetime measurement and applied it to a mouse xenograft model of activated human pancreatic cancer generated by subcutaneous injection of AsPC-1 tumor cells. Using this method with pH-sensitive sodium fluorescein injection, we demonstrated discrimination between normal and cancerous tissues in a living mouse. With further development, this method may be useful for clinical cancer detection.

  20. Nuclear-data evaluation based on direct and indirect measurements with general correlations

    International Nuclear Information System (INIS)

    Muir, D.W.

    1988-01-01

    Optimum procedures for the statistical improvement, or updating, of an existing nuclear-data evaluation are reviewed and redeveloped from first principles, consistently employing a minimum-variance viewpoint. A set of equations is derived which provides improved values of the data and their covariances, taking into account information from supplementary measurements and allowing for general correlations among all measurements. The minimum-variance solutions thus obtained, which we call the method of 'partitioned least squares,' are found to be equivalent to a method suggested by Yu. V. Linnik and applied by a number of authors to the analysis of fission-reactor integral experiments; however, up to now, the partitioned-least-squares formulae have not found widespread use in the field of basic data evaluation. This approach is shown to give the same results as the more commonly applied Normal equations, but with reduced matrix inversion requirements. Examples are provided to indicate potential areas of application. (author)

  1. Development of a direct measurement system for the standardization of neutron emission rates

    International Nuclear Information System (INIS)

    Ogheard, Florestan

    2012-01-01

    The manganese bath technique is the reference method for neutron source emission rates calibration. It is used to calibrate neutron sources using radionuclides (AmBe, PuBe, "2"5"2Cf,...) in terms of neutron emission rate under 4π sr. As a complement to this technique, the anisotropy of the source is measured using a rotating source holder and a neutron long counter. The neutron source to be measured is immersed in a manganese sulphate solution whereby the emitted neutrons are captured within the bath contents. In a typical configuration (a 1 m diameter sphere and a concentrated solution), approximately half of the neutrons lead to the creation of "5"6Mn via the "5"5Mn(n, γ) capture reaction. The "5"6Mn radionuclide has a half-life of approximately 2.6 hours and the bath reaches saturation when the number of nuclei decaying is equal to the number of nuclei created per unit time. The neutron emission rate from the source can then be deduced from the "5"6Mn activity at saturation, assuming proper modelling of the nuclear reactions occurring in the bath. The manganese bath facility at LNE-LNHB has been recently refurbished in order to comply with appropriate safety and radioprotection regulations. This has lead to the upgrading of both the measurement methodology and the modelling of the bath, and a study on the development of a new detector for the on-line measurement of the manganese activity was started. This new detector uses the β-γ coincidence measurement method. The beta channel consists of two photomultipliers tubes which allow the detection of Cerenkov light, and the gamma channel uses a solid scintillation detector. The advantage of this measurement method is that it allows the determination of the bath activity without any prior calibration, unlike the former method which uses a gamma-ray detector calibrated using a high activity manganese source. The principle of the Cerenkov-gamma coincidence measurement has been validated by a prototype of the

  2. Locally measuring the adhesion of InP directly bonded on sub-100 nm patterned Si

    International Nuclear Information System (INIS)

    Pantzas, K; Patriarche, G; Beaudoin, G; Itawi, A; Sagnes, I; Talneau, A; Bourhis, E Le; Troadec, D

    2016-01-01

    A nano-scale analogue to the double cantilever experiment that combines instrumented nano-indentation and atomic force microscopy is used to precisely and locally measure the adhesion of InP bonded on sub-100 nm patterned Si using oxide-free or oxide-mediated bonding. Surface-bonding energies of 0.548 and 0.628 J m"−"2, respectively, are reported. These energies correspond in turn to 51% and 57% of the surface bonding energy measured in unpatterned regions on the same samples, i.e. the proportion of unetched Si surface in the patterned areas. The results show that bonding on patterned surfaces can be as robust as on unpatterned surfaces, provided care is taken with the post-patterning surface preparation process and, therefore, open the path towards innovative designs that include patterns embedded in the Si guiding layer of hybrid III-V/Si photonic integrated circuits. (paper)

  3. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  4. The distribution of snow accumulation across the Austfonna ice cap, Svalbard: direct measurements and modelling

    OpenAIRE

    Taurisano, Andrea; Schuler, Thomas V.; Hagen, Jon Ove; Eiken, Trond; Loe, Even; Melvold, Kjetil; Kohler, Jack

    2007-01-01

    We present an analysis of the spatial variability in the snow accumulation on the Austfonna ice cap in Svalbard, Norway, based on the results of field investigations conducted in the spring of 1999, 2004 and 2005. During the campaigns ground penetrating radar measurements at 500 and 800 MHz were collected along profiles, along with additional manual snow sounding and pit stratigraphy work. The analysis of the data reveals a consistent pattern in the spatial distribution of the snow accumulati...

  5. Direct measurement of the partial decay energy of 7Be inner bremstrahlung spectrum

    International Nuclear Information System (INIS)

    Sanjeeviah, H.; Sanjeeviah, B.

    1978-01-01

    The inner bremsstrahlung spectrum accompanying orbital electron capture decay of 7 Be to the first excited state of 7 Li was measured in coincidence with 477 keV gamma rays. From the Jauch plot of the spectrum the partial decay energy was found to be 394 +- 16 keV. The shape factor of the inner bremsstrahlung spectrum close to the end point was accurately determined. It was found to be a constant X(1.001 +- 0.002) (author)

  6. Direct measurement of macroscopic electric fields produced by collective effects in electron-impact experiments

    International Nuclear Information System (INIS)

    Velotta, R.; Avaldi, L.; Camilloni, R.; Giammanco, F.; Spinelli, N.; Stefani, G.

    1996-01-01

    The macroscopic electric field resulting from the space charge produced in electron-impact experiments has been characterized by using secondary electrons of well-defined energy (e.g., Auger or autoionizing electrons) as a probe. It is shown that the measurement of the kinetic-energy shifts suffered by secondary electrons is a suitable tool for the analysis of the self-generated electric field in a low-density plasma. copyright 1996 The American Physical Society

  7. Direct measurement of skeletal muscle fatigue in patients with chronic heart failure.

    OpenAIRE

    Buller, N P; Jones, D; Poole-Wilson, P A

    1991-01-01

    Skeletal muscle function was measured as force production and fatigue in both the quadriceps (a large locomotive muscle) and adductor pollicis (a small intrinsic hand muscle) in five healthy volunteers, five patients with mild chronic heart failure, and five patients with severe chronic heart failure. The quadriceps of patients with chronic heart failure had a reduced muscle cross sectional area, a reduced maximum isometric force production, and an increased tendency to fatigue. Isometric for...

  8. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples.

    Science.gov (United States)

    Potamias, Dimitrios; Alxneit, Ivo; Wokaun, Alexander

    2017-09-01

    The design, implementation, calibration, and assessment of double modulation pyrometry to measure surface temperatures of radiatively heated samples in our 1 kW imaging furnace is presented. The method requires that the intensity of the external radiation can be modulated. This was achieved by a rotating blade mounted parallel to the optical axis of the imaging furnace. Double modulation pyrometry independently measures the external radiation reflected by the sample as well as the sum of thermal and reflected radiation and extracts the thermal emission as the difference of these signals. Thus a two-step calibration is required: First, the relative gains of the measured signals are equalized and then a temperature calibration is performed. For the latter, we transfer the calibration from a calibrated solar blind pyrometer that operates at a different wavelength. We demonstrate that the worst case systematic error associated with this procedure is about 300 K but becomes negligible if a reasonable estimate of the sample's emissivity is used. An analysis of the influence of the uncertainties in the calibration coefficients reveals that one (out of the five) coefficient contributes almost 50% to the final temperature error. On a low emission sample like platinum, the lower detection limit is around 1700 K and the accuracy typically about 20 K. Note that these moderate specifications are specific for the use of double modulation pyrometry at the imaging furnace. It is mainly caused by the difficulty to achieve and maintain good overlap of the hot zone with a diameter of about 3 mm Full Width at Half Height and the measurement spot both of which are of similar size.

  9. Electrical limit of silver nanowire electrodes: Direct measurement of the nanowire junction resistance

    KAUST Repository

    Selzer, Franz; Floresca, Carlo; Kneppe, David; Bormann, Ludwig; Sachse, Christoph; Weiß , Nelli; Eychmü ller, Alexander; Amassian, Aram; Mü ller-Meskamp, Lars; Leo, Karl

    2016-01-01

    We measure basic network parameters of silvernanowire (AgNW) networks commonly used as transparent conductingelectrodes in organic optoelectronic devices. By means of four point probing with nanoprobes, the wire-to-wire junction resistance and the resistance of single nanowires are measured. The resistanceRNW of a single nanowire shows a value of RNW=(4.96±0.18) Ω/μm. The junction resistanceRJ differs for annealed and non-annealed NW networks, exhibiting values of RJ=(25.2±1.9) Ω (annealed) and RJ=(529±239) Ω (non-annealed), respectively. Our simulation achieves a good agreement between the measured network parameters and the sheet resistanceRS of the entire network. Extrapolating RJ to zero, our study show that we are close to the electrical limit of the conductivity of our AgNW system: We obtain a possible RS reduction by only ≈20% (common RS≈10 Ω/sq). Therefore, we expect further performance improvements in AgNW systems mainly by increasing NW length or by utilizing novel network geometries.

  10. Direct measurement of interstellar extinction toward young stars using atomic hydrogen Lyα absorption

    Energy Technology Data Exchange (ETDEWEB)

    McJunkin, Matthew; France, Kevin; Brown, Alexander [Center for Astrophysics and Space Astronomy, University of Colorado, 389 UCB, Boulder, CO 80309 (United States); Schneider, P. C. [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany); Herczeg, Gregory J. [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China); Hillenbrand, Lynne [California Institute of Technology, Department of Astrophysics, MC105-24, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Schindhelm, Eric [Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States); Edwards, Suzan, E-mail: matthew.mcjunkin@colorado.edu [Five College Astronomy Department, Smith College, Northampton, MA 01063 (United States)

    2014-01-10

    Interstellar reddening corrections are necessary to reconstruct the intrinsic spectral energy distributions (SEDs) of accreting protostellar systems. The stellar SED determines the heating and chemical processes that can occur in circumstellar disks. Measurement of neutral hydrogen absorption against broad Lyα emission profiles in young stars can be used to obtain the total H I column density (N(H I)) along the line of sight. We measure N(H I) with new and archival ultraviolet observations from the Hubble Space Telescope (HST) of 31 classical T Tauri and Herbig Ae/Be stars. The H I column densities range from log{sub 10}(N(H I)) ≈19.6-21.1, with corresponding visual extinctions of A{sub V} =0.02-0.72 mag, assuming an R{sub V} of 3.1. We find that the majority of the H I absorption along the line of sight likely comes from interstellar rather than circumstellar material. Extinctions derived from new HST blue-optical spectral analyses, previous IR and optical measurements, and new X-ray column densities on average overestimate the interstellar extinction toward young stars compared to the N(H I) values by ∼0.6 mag. We discuss possible explanations for this discrepancy in the context of a protoplanetary disk geometry.

  11. Electrical limit of silver nanowire electrodes: Direct measurement of the nanowire junction resistance

    KAUST Repository

    Selzer, Franz

    2016-04-19

    We measure basic network parameters of silvernanowire (AgNW) networks commonly used as transparent conductingelectrodes in organic optoelectronic devices. By means of four point probing with nanoprobes, the wire-to-wire junction resistance and the resistance of single nanowires are measured. The resistanceRNW of a single nanowire shows a value of RNW=(4.96±0.18) Ω/μm. The junction resistanceRJ differs for annealed and non-annealed NW networks, exhibiting values of RJ=(25.2±1.9) Ω (annealed) and RJ=(529±239) Ω (non-annealed), respectively. Our simulation achieves a good agreement between the measured network parameters and the sheet resistanceRS of the entire network. Extrapolating RJ to zero, our study show that we are close to the electrical limit of the conductivity of our AgNW system: We obtain a possible RS reduction by only ≈20% (common RS≈10 Ω/sq). Therefore, we expect further performance improvements in AgNW systems mainly by increasing NW length or by utilizing novel network geometries.

  12. Direct measurements of relaxation times of phosphorus metabolites in the human myocardium

    International Nuclear Information System (INIS)

    Schindler, R.; Krahe, T.; Neubauer, S.; Hillenbrand, H.; Entzeroth, C.; Horn, M.; Lackner, K.; Ertl, G.

    1992-01-01

    The T 1 relaxation times of the phosphorus metabolites in human heart muscle measurable by 31 P-MR spectra were determined in 12 individuals using a 1.5 Tesla system. Several spectra were recorded consecutively with a pulse repetition time of 1.6s to 24 s. The T 1 times of creatine phosphate (CP), of γ-, α-, β-adenosintriphosphate (ATP), 2,3-diphosphoglycerate (2,3-DPG) together with anorganic phosphate) and phosphodiester (PDE) showed mean measurements of 6.1±0.5, 5.4±0.5, 5.0±0.5, 5.8±1.0, 7.6±1.0, and 5.0±1.0s (M±SE). The accuracy of the ISIS technique was tested with a special phantom. T 1 times were also measured in standard solutions (20mM CP, 10mM ATP); CP was 8.7±0.2s and γ-ATP was 9.9±0.7s. Corrections for partially saturated 31 P-MR spectra - at least for CP/ATP ratios - are relatively small. (orig.) [de

  13. Leishmania amazonensis chemotaxis under glucose gradient studied by the strength and directionality of forces measured with optical tweezers

    Science.gov (United States)

    de Ysasa Pozzo, Liliana; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz Carlos; Ayres, Diana Copi; Giorgio, Selma; Cesar, Carlos Lenz

    2007-02-01

    Chemotaxis is the mechanism microorganisms use to sense the environment surrounding them and to direct their movement towards attractive, or away from the repellent, chemicals. The biochemical sensing is almost the only way for communication between unicellular organisms. Prokaryote and Eukaryote chemotaxis has been mechanically studied mainly by observing the directionality and timing of the microorganisms movements subjected to a chemical gradient, but not through the directionality and strength of the forces it generates. To observe the vector force of microorganisms under a chemical gradient we developed a system composed of two large chambers connected by a tiny duct capable to keep the chemical gradient constant for more than ten hours. We also used the displacements of a microsphere trapped in an Optical Tweezers as the force transducer to measure the direction and the strength of the propulsion forces of flagellum of the microorganism under several gradient conditions. A 9μm diameter microsphere particle was trapped with a Nd:YAG laser and its movement was measured through the light scattered focused on a quadrant detector. We observed the behavior of the protozoa Leishmania amazonensis (eukaryote) under several glucose gradients. This protozoa senses the gradient around it by swimming in circles for three to five times following by tumbling, and not by the typical straight swimming/tumbling of bacteria. Our results also suggest that force direction and strength are also used to control its movement, not only the timing of swimming/tumbling, because we observed a higher force strength clearly directed towards the glucose gradient.

  14. Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy

    DEFF Research Database (Denmark)

    Loudon, J. C.; Yazdi, Sadegh; Kasama, Takeshi

    2015-01-01

    We demonstrate that images of flux vortices in a superconductor taken with a transmission electron microscope can be used to measure the penetration depth and coherence length in all directions at the same temperature and magnetic field. This is particularly useful for MgB2, where these quantities...... vary with the applied magnetic field and values are difficult to obtain at low field or in the c direction. We obtained images of flux vortices from a MgB2 single crystal cut in the ac plane by focused ion beam milling and tilted to 45 degrees. with respect to the electron beam about...... the crystallographic a axis. A new method was developed to simulate these images that accounted for vortices with a nonzero core in a thin, anisotropic superconductor and a simplex algorithm was used to make a quantitative comparison between the images and simulations to measure the penetration depths and coherence...

  15. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  16. Status on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kulisek, Jonathan A.; Anderson, Kevin K.; Casella, Andrew M.; Gesh, Christopher J.; Warren, Glen A.; Gavron, Victor A.; Devlin, M.; Haight, R. C.; O' Donnell, J. M.; Danon, Yaron; Weltz, Adam; Bonebrake, Eric; Imel, G. R.; Harris, Jason; Beller, Dennis; Hatchett, D.; Droessler, J.

    2012-08-30

    Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy. This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.

  17. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  18. Normal and system lupus erythematosus red blood cell interactions studied by double trap optical tweezers: direct measurements of aggregation forces

    Science.gov (United States)

    Khokhlova, Maria D.; Lyubin, Eugeny V.; Zhdanov, Alexander G.; Rykova, Sophia Yu.; Sokolova, Irina A.; Fedyanin, Andrey A.

    2012-02-01

    Direct measurements of aggregation forces in piconewton range between two red blood cells in pair rouleau are performed under physiological conditions using double trap optical tweezers. Aggregation and disaggregation properties of healthy and pathologic (system lupus erythematosis) blood samples are analyzed. Strong difference in aggregation speed and behavior is revealed using the offered method which is proposed to be a promising tool for SLE monitoring at single cell level.

  19. Determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities

    International Nuclear Information System (INIS)

    Rius, J.; Miravitlles, C.

    1988-01-01

    A strategy for the determination of crystal structures with large known fragments directly from measured X-ray powder diffraction intensities is presented. It is based on the automated full-symmetry Patterson search method described by Rius and Miravitlles where the Fourier coefficients of the observed Patterson function are modified to allow the use of powder diffraction intensity data. Its application to two structures, one with simulated and one with experimental data, is shown. (orig.)

  20. First direct landscape-scale measurement of tropical rain forest Leaf Area Index, a key driver of global primary productivity

    Science.gov (United States)

    David B. Clark; Paulo C. Olivas; Steven F. Oberbauer; Deborah A. Clark; Michael G. Ryan

    2008-01-01

    Leaf Area Index (leaf area per unit ground area, LAI) is a key driver of forest productivity but has never previously been measured directly at the landscape scale in tropical rain forest (TRF). We used a modular tower and stratified random sampling to harvest all foliage from forest floor to canopy top in 55 vertical transects (4.6 m2) across 500 ha of old growth in...