  1. A century of indicator dilution technique

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Jensen, Gorm B; Larsson, Henrik B W

    2014-01-01

    This review imparts the history and the present status of the indicator dilution technique with quantitative bolus injection. The first report on flow measurement with this technique appeared 100 years ago. In 1928, the use of intravascular dyes made possible a widespread application in animals...

  2. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  3. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition.

    Science.gov (United States)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita; Friis, Henrik; Kurpad, Anura; Wells, Jonathan C

    2017-08-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work to develop and adapt the deuterium dilution technique. We refined procedures for administration of isotope doses and collection of saliva. Furthermore, we established that equilibration time in local context is 3 h. These findings and the resulting standard operating procedures are important to improve data quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques.

  4. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition

    DEFF Research Database (Denmark)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita

    2017-01-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body...... composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work...... quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques....

  5. Renal artery blood flow assessed by video dilution technique before and after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Link, D.P.; Lewis, E.L.; Foerster, J.M.; Lee, G.

    1981-01-01

    Successful percutaneous transluminal angioplasty was performed in 3 cases of renal artery stenosis where the effect upon renal blood flow was quantified by video dilution technique. This technique adds important information to pressure gradients and renin assays obtained during the dilatation procedure. (Auth.)

  6. Investigation of CTBT OSI Radionuclide Techniques at the DILUTED WATERS Nuclear Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Baciak, James E.; Milbrath, Brian D.; Detwiler, Rebecca S.; Kirkham, Randy R.; Keillor, Martin E.; Lepel, Elwood A.; Seifert, Allen; Emer, Dudley; Floyd, Michael

    2012-11-01

    Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), a verification regime that includes the ability to conduct an On-Site Inspection (OSI) will be established. The Treaty allows for an OSI to include many techniques, including the radionuclide techniques of gamma radiation surveying and spectrometry and environmental sampling and analysis. Such radioactivity detection techniques can provide the “smoking gun” evidence that a nuclear test has occurred through the detection and quantification of indicative recent fission products. An OSI faces restrictions in time and manpower, as dictated by the Treaty; not to mention possible logistics difficulties due to the location and climate of the suspected explosion site. It is thus necessary to have a good understanding of the possible source term an OSI will encounter and the proper techniques that will be necessary for an effective OSI regime. One of the challenges during an OSI is to locate radioactive debris that has escaped an underground nuclear explosion (UNE) and settled on the surface near and downwind of ground zero. To support the understanding and selection of sampling and survey techniques for use in an OSI, we are currently designing an experiment, the Particulate Release Experiment (PRex), to simulate a small-scale vent from an underground nuclear explosion. PRex will occur at the Nevada National Security Site (NNSS). The project is conducted under the National Center for Nuclear Security (NCNS) funded by the National Nuclear Security Agency (NNSA). Prior to the release experiment, scheduled for Spring of 2013, the project scheduled a number of activities at the NNSS to prepare for the release experiment as well as to utilize the nuclear testing past of the NNSS for the development of OSI techniques for CTBT. One such activity—the focus of this report—was a survey and sampling campaign at the site of an old UNE that vented: DILUTED WATERS. Activities at DILUTED WATERS included vehicle-based survey

  7. Study of dilution of effluent discharged through a sea outfall near Mangalore using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.

    1987-01-01

    The fate of effluent discharged into water bodies is a matter of concern from the point of view of environmental pollution. Radiotracer techniques have been successfully used to study the change in concentration of effluents while being mixed with large water bodies. The technique used is to add a known concentration of radioactive tracer into the effluent stream and to measure the dilutions at different locations near the effluent discharge point with radiation detectors. M/s Mangalore Chemicals and Fertilizers Ltd (MCF) at Mangalore on the west coast of India disposes off the treated and initially diluted effluent at the rate of about 360 m 3 /h into the sea near by through an outfall extending about 100 meters into the sea. The effluent mainly contains ammonia in the range of 40-50 ppm as the pollutant. It was desired to measure the extent of dilution occurring to the effluent at a few locations of known distances along the sea shore from the discharge point of the effluent. Radiotracers 82 Br as ammonium bromide solution and tritium as tritiated water were employed for the study. The concentration measurement was done at site for 82 Br and by estimation of samples in the laboratory in the case of tritium. Dilution of the order of 1000 was obtained at about 100 meters distance for a continuous injection of about 4 hours. (author). 3 tables, 3 figures

  8. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  9. Simulation of limiting dilution technique in determination of immunocompetent cells frequency in irradiated cell cultures

    International Nuclear Information System (INIS)

    Martini Filho, R.J.; Barlette, V.E.; Goes, E.G.; Covas, D.T.; Orellana, M.

    2001-01-01

    Limiting dilution techniques (LDA) dose-response data have been used to detect immunocompetent T-Cells in microcultures. In this work, LDA frequencies estimates was obtained using χ2 minimization for irradiated cells in a range of 500 to 1,500 cGy. (author)

  10. 15N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    International Nuclear Information System (INIS)

    Ventura, Wilbur; Watanabe, Iwao

    1983-01-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the 15 N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. 15 N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower 15 N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N 2 fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the 15 N content of plants decreased in allowing the photodependent N 2 fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N 2 fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the 15 N dilution technique using the rice-covered soil as reference system. (Mori, K.)

  11. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  12. Vitamin A equivalency and apparent absorption of ß-carotene in ileostomy subjects using a dual-isotope dilution technique

    NARCIS (Netherlands)

    Bouwman, C.A.; Naber, T.H.J.; Breemen, van R.B.; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.M.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of ß-carotene in two diets using a dual-isotope dilution technique and the apparent ß-carotene absorption as measured by the oral–faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  13. Vitamin A equivalency and apparent absorption of beta-carotene in ileostomy subjects using a dual-isotope dilution technique.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; Naber, T.H.; Breemen, R.B. van; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of beta-carotene in two diets using a dual-isotope dilution technique and the apparent beta-carotene absorption as measured by the oral-faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  14. /sup 15/N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    Energy Technology Data Exchange (ETDEWEB)

    Ventura, W; Watanabe, Iwao [International Rice Research Inst., College, Laguna (Phillippines)

    1983-06-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the /sup 15/N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. /sup 15/N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower /sup 15/N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N/sub 2/ fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the /sup 15/N content of plants decreased in allowing the photodependent N/sub 2/ fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N/sub 2/ fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the /sup 15/N dilution technique using the rice-covered soil as reference system.

  15. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Pak, Yong Nam

    2016-01-01

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA

  16. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Pak, Yong Nam [Dept. of Chemistry Education, Korea National University of Education, Cheongju (Korea, Republic of)

    2016-11-15

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA.

  17. Determination of total uranium by mass spectrometry utilizing the isotopic dilution technique

    International Nuclear Information System (INIS)

    Cretella, R.F.; Noutary, C.J.; Servant, R.E.

    1981-01-01

    The isotopic dilution associated to mass spectrometry is a high-sensitivity technique that allows to work with microquantities of the sample, making it possible to analize the content in highly radioactive solutions with excellent accuracy and minimum risk. The proposed technique is described and its results are discussed through the analysis of: 1) A synthetic sample that simulates dissolved spent fuel elements; 2) Uranium dioxide of nuclear purity and 3) Uranium concentrate. 233 U(ORNL) was employed as a tracer and a Nuclide 12-90-SU mass spectrometer of simple magnetic focus as measurement instrument. The accuracy reached in the analyses is better than 0.5% with a reliability of 95%. The analysis of the errors shows that their main contributing source are the errors in the measurement of the isotopic ratios. (M.E.L.) [es

  18. DMSP and DMS dynamics and microzooplankton grazing in the Labrador Sea: application of the dilution technique

    Science.gov (United States)

    Wolfe, Gordon V.; Levasseur, Maurice; Cantin, Guy; Michaud, Sonia

    2000-12-01

    We adapted the dilution technique to study microzooplankton grazing of algal dimethylsulfoniopropionate (DMSP) vs. Chl a, and to estimate the impact of microzooplankton grazing on dimethyl sulfide (DMS) production in the Labrador Sea. Phytoplankton numbers were dominated by autotrophic nanoflagellates in the Labrador basin, but diatoms and colonial Phaeocystis pouchetii contributed significantly to phytomass at several high chlorophyll stations and on the Newfoundland and Greenland shelfs. Throughout the region, growth of algal Chl a and DMSP was generally high (0.2-1 d -1), but grazing rates were lower and more variable, characteristic of the early spring bloom period. Production and consumption of Chl a vs. DMSP followed no clear pattern, and sometimes diverged greatly, likely because of their differing distributions among algal prey taxa and size class. In several experiments where Phaeocystis was abundant, we observed DMS production proportional to grazing rate, and we found clear evidence of DMS production by this haptophyte following physical stress such as sparging or filtration. It is possible that grazing-activated DMSP cleavage by Phaeocystis contributes to grazer deterrence: protozoa and copepods apparently avoided healthy colonies (as judged by relative growth and grazing rates of Chl a and DMSP), and grazing of Phaeocystis was significant only at one station where cells were in poor condition. Although we hoped to examine selective grazing on or against DMSP-containing algal prey, the dilution technique cannot differentiate selective ingestion and varying digestion rates of Chl a and DMSP. We also found that the dilution method alone was poorly suited for assessing the impact of grazing on dissolved sulfur pools, because of rapid microbial consumption and the artifactual release of DMSP and DMS during filtration. Measuring and understanding the many processes affecting organosulfur cycling by the microbial food web in natural populations remain a

  19. Cardiac output determined by echocardiography in patients with cirrhosis: comparison with the indicator dilution technique

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Møller, Søren; Bendtsen, Flemming

    2003-01-01

    technique (CO(I)). METHODS: Twelve patients with cirrhosis were studied. CO(d) was measured as the spatial mean velocity of the left ventricular outflow tract, multiplied by the cross-sectional area and the heart rate. CO(I) was determined by the standard indicator dilution technique after injection of 125I...... albumin and 99mTc albumin into the right atrium and subsequent sampling from the femoral artery. RESULTS: The mean CO(d) and CO(I) were similar (7.20 vs 7.15 l/min, NS). A highly significant correlation was present between CO(d) and CO(I) (r = 0.86, P

  20. The relation of plasma octopamine to hepatic encephalopathy studied with stable isotope dilution technique

    International Nuclear Information System (INIS)

    Zhang Jianhua

    1992-01-01

    In order to investigate the relationship between octopamine and hepatic encephalopathy, plasma octopamine content of normal adults and hepatic patients (compensated or de-compensated cirrhotic, patients with encephalopathy) were determined with isotope dilution and GCMS technique, 200 ng of [1, 1-D]-octopamine was added to each sample as internal standard. After the de-proteinized plasma was subjected to cation exchange chromatography, the amine fraction was derivatized with PFP and analyzed with GCMS using the selected ion monitoring technique. The result showed that the level of plasma octopamine was significantly elevated in patients with encephalopathy. Since this method is sensitive and specific, it is readily applicable to the analysis of a few nano grams of octopamine

  1. Application of the mass spectrometry-isotope dilution technique for the determination of uranium contents in rocks

    International Nuclear Information System (INIS)

    Kakazu, M.H.; Iyer, S.S.

    1980-01-01

    Application of the spectrometric isotope dilution technique for the accurate determination of parts per million range of uranium in rock samples is described. The various aspects of the method like sample dissolution, ion exchange separation, mass spectrometric procedures are discussed. A single filament ionization source was employed for the isotope analysis. A carbon reduction method was used to reduce uranium oxide ions to uranium metal ions. The tracer solution for isotope dilution was prepared from National Bureau of Standards uranium isotopic Standard NBS U-970. Uranium contents are meassured for nine rock samples and the values obtained are compared with the uranium values measured by others workers. Errors caused in the uranium determination due to sample splitting problems as well as the incomplete acid digestion of the samples are discussed. (Author) [pt

  2. Isotope dilution analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fudge, A.

    1978-12-15

    The following aspects of isotope dilution analysis are covered in this report: fundamental aspects of the technique; elements of interest in the nuclear field, choice and standardization of spike nuclide; pre-treatment to achieve isotopic exchange and chemical separation; sensitivity; selectivity; and accuracy.

  3. Effects of the technique of cryopreservation and dilution/centrifugation after thawing on the motility and vitality of spermatozoa of oligoasthenozoospermic men

    Directory of Open Access Journals (Sweden)

    Esteves Sandro C.

    2003-01-01

    Full Text Available OBJECTIVE: Comparing in human semen samples with low initial quality, the effects of 2 techniques of cryopreservation and dilution/centrifugation after thawing on the spermatic motility and vitality. MATERIALS AND METHODS: Semen samples from 15 oligo and/or asthenozoospermic individuals assisted in the infertility sector of a tertiary hospital were obtained through masturbation. The samples were divided into 2 portions of equal volume, and diluted (1:1; v/v with the cryoprotector containing glycerol (Test yolk buffer. One portion was frozen through the technique of liquid nitrogen vapor with static phases (group I - GI, while the other was frozen through a programmable biological freezer with linear speed (Planer, Kryo 10, series III (group II - GII. The following parameters were assessed before freezing and after thawing: percentage of spermatozoa with progressive motility (Prog% and percentage of live spermatozoa (Vit%. After defrosting, Prog% was assessed before and after removal of cryoprotector diluent, in different time intervals (zero, 3 h, and 24 h. The statistical analysis has been accomplished by using the non-parametric tests of Wilcoxon and Friedman. RESULTS: There was significant reduction of Prog% and Vit% from before freezing to after defrosting in both groups, I and II (p < 0.001. Values of Prog% and Vit% were not statistically different between groups, after thawing. It has been observed a significant reduction in Prog% among portions frozen with the automated technique after dilution and centrifugation for removal of cryoprotector (p = 0.006. After cryoprotector removal, Prog% has been kept unaltered, in both groups, during the first 3 hours of incubation, although being superior in group I (p = 0,04. There was a significant decrease in Prog% after 24 hours of incubation, in both groups (p < 0,01. CONCLUSION: For human semen samples with low initial quality, freezing through vapor technique or through the automated technique

  4. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; West, C.E.; Breemen, R.B. van; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.; Lieshout, M. van; Russel, F.G.M.; Schaafsma, G.; Naber, A.H.J.

    2009-01-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted

  5. Utilization of tritiated water dilution technique in determination of nitrogen partitioning in cashmere goats

    International Nuclear Information System (INIS)

    Wang Linfeng; Yang Gaiqing; Liu Ping; Zhang Shijun

    2010-01-01

    In order to investigate nitrogen partitioning in local cashmere goats, six Inner Mogolia White Cashmere goats between 2 to 2.5 years old were used to determine the nitrogen partitioning in cashmere goats. The total retained nitrogen (TN) in body, distribution of body nitrgen and hair nitrogen were measured by general digestive and metabolism method combined with tritiated water dilution technique. Results showed that the combined methods were ideal for determining body nitrgen (BN) and hair nitrogen (fur nitrogen, FN) of Cashmere goats. There were obvious significance between BN and FN in different seasons. In telogen, BN and FN partitioning was 75.7% ± 0.62% and 24.3% ± 0.62%, respectively. Whereas, it changed to 66.6% ± 2.2% and 33.4% ± 2.2% in anagen. BN partitioning decreased when the season changed from telogen to anagen, while FN partitioning increased, which indicated that more nitrogen substance was partitioned to body growth in telogen, and more nitrogen substance was distribute to cashmere growth in anagen. These transformation were related to the changing of photoperiod and some hormones, such as melatonin (MT), prolactin (PRL) and IGF-I. It could be concluded that tritiated water dilution technique can be used to detect body protein content as well as BN, combining general digestive and metabolism experiment, FN partitoning can be determined. BN and FN partitoning varied with the season in cashmere goats because of hormones changing. (authors)

  6. Vitamin A equivalency of ß-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect

    NARCIS (Netherlands)

    Bouwman, C.A.; West, C.E.; Breemen, van R.B.; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.M.; Lieshout, van M.; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.J.

    2009-01-01

    Data on the vitamin A equivalency of ß-carotene in food are inconsistent. We quantified the vitamin A equivalency (¿g) of ß-carotene in two diets using the dual-isotope dilution technique and the oral¿faecal balance technique. A diet-controlled, cross-over intervention study was conducted in

  7. Dilution Confusion: Conventions for Defining a Dilution

    Science.gov (United States)

    Fishel, Laurence A.

    2010-01-01

    Two conventions for preparing dilutions are used in clinical laboratories. The first convention defines an "a:b" dilution as "a" volumes of solution A plus "b" volumes of solution B. The second convention defines an "a:b" dilution as "a" volumes of solution A diluted into a final volume of "b". Use of the incorrect dilution convention could affect…

  8. Effects of the technique of cryopreservation and dilution/centrifugation after thawing on the motility and vitality of spermatozoa of oligoasthenozoospermic men.

    Science.gov (United States)

    Esteves, Sandro C; Spaine, Deborah M; Cedenho, Agnaldo P; Srougi, Miguel

    2003-01-01

    Comparing in human semen samples with low initial quality, the effects of 2 techniques of cryopreservation and dilution/centrifugation after thawing on the spermatic motility and vitality. Semen samples from 15 oligo and/or asthenozoospermic individuals assisted in the infertility sector of a tertiary hospital were obtained through masturbation. The samples were divided into 2 portions of equal volume, and diluted (1:1; v/v) with the cryoprotector containing glycerol (Test yolk buffer). One portion was frozen through the technique of liquid nitrogen vapor with static phases (group I - GI), while the other was frozen through a programmable biological freezer with linear speed (Planer, Kryo 10, series III) (group II - GII). The following parameters were assessed before freezing and after thawing: percentage of spermatozoa with progressive motility (Prog%) and percentage of live spermatozoa (Vit%). After defrosting, Prog% was assessed before and after removal of cryoprotector diluent, in different time intervals (zero, 3 h, and 24 h). The statistical analysis has been accomplished by using the non-parametric tests of Wilcoxon and Friedman. There was significant reduction of Prog% and Vit% from before freezing to after defrosting in both groups, I and II (p live spermatozoa with progressive motility. The effects of dilution and centrifugation to remove the cryoprotector had a negative impact only in samples frozen through the automated technique. In both techniques, progressive motility is kept constant during the first 3 hours after thawing and removal of the cryoprotector, but is drastically diminished by the end of an incubation period of 24 hours.

  9. Estimation of endogenous faecal calcium in buffalo (BOS bubalis) by isotope dilution technique

    International Nuclear Information System (INIS)

    Singh, S.; Sareen, V.K.; Marwaha, S.R.; Sekhon, B.; Bhatia, I.S.

    1973-01-01

    Detailed investigations on the isotope-dilution technique for the estimation of endogenous faecal calcium were conducted with buffalo calves fed on growing ration. The ration consisted of wheat straw, green lucerne and concentrate mix. The endogenous faecal calcium was 3.71 g/day, which is 17.8 percent of the total faecal calcium. The apparent and true digestibilities of Ca were calculated as 51 and 60 percent respectively. The endogenous faecal calcium can be estimated in buffalo calves by giving single subcutaneous injection of Ca 45 and collecting blood samples on 12th and 21st days only, and representative sample from the faeces collected from 13th through 22nd day after the injection. (author)

  10. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  11. Gluconeogenesis from labeled carbon: estimating isotope dilution

    International Nuclear Information System (INIS)

    Kelleher, J.K.

    1986-01-01

    To estimate the rate of gluconeogenesis from steady-state incorporation of labeled 3-carbon precursors into glucose, isotope dilution must be considered so that the rate of labeling of glucose can be quantitatively converted to the rate of gluconeogenesis. An expression for the value of this isotope dilution can be derived using mathematical techniques and a model of the tricarboxylic acid (TCA) cycle. The present investigation employs a more complex model than that used in previous studies. This model includes the following pathways that may affect the correction for isotope dilution: 1) flux of 3-carbon precursor to the oxaloacetate pool via acetyl-CoA and the TCA cycle; 2) flux of 4- or 5-carbon compounds into the TCA cycle; 3) reversible flux between oxaloacetate (OAA) and pyruvate and between OAA and fumarate; 4) incomplete equilibrium between OAA pools; and 5) isotope dilution of 3-carbon tracers between the experimentally measured pool and the precursor for the TCA-cycle OAA pool. Experimental tests are outlined which investigators can use to determine whether these pathways are significant in a specific steady-state system. The study indicated that flux through these five pathways can significantly affect the correction for isotope dilution. To correct for the effects of these pathways an alternative method for calculating isotope dilution is proposed using citrate to relate the specific activities of acetyl-CoA and OAA

  12. EXAFS of dilute systems: fluorescence detection

    International Nuclear Information System (INIS)

    Hastings, J.B.

    1979-01-01

    Since the first observations of the variation of the absorption coefficient for x-rays above the energy thresholds in the thirties until the early seventies, measurements and analysis of these variations were merely intended for the understanding of the underlying physics. Recently, with the understanding of the information available about the local atomic structure in the neighborhood of the absorbing species and the availability of high intensity synchrotron radiation sources, EXAFS has become a powerful structural tool. In these discussions, the details of the measurements for very dilute species are presented. It is shown that for the more dilute systems the measurement of the emission rather than the direct absorption is a more favorable technique

  13. Study of ferrallitisation process in soil by application of isotopic dilution kinetic technique to iron

    International Nuclear Information System (INIS)

    Thomann, Christiane

    1978-01-01

    Isotopic dilution kinetic technique applied to iron may contribute to make clear the conditions of ''potential'' mobility of iron in soils, under the action of three factors: moisture, incubation period and organic matter imputs. Comparison between surface horizons of three tropical soils: leached ferruginous tropical soil, weakly ferrallitic red soil and ferrallitic soil shows that in the ferrallitisation process, weakly ferrallitic soil would take place between the two other types of soils with a maximum mobility of iron. This mobility decreases when organic matter rate decreases leading then to ''beige'' soil (ferruginous leached tropical soil), and when hydroxide rate increases, which leads to ferrallitic soil. In podzol (A 1 horizon), for the same rate of organic matter, potential mobility of iron is higher than in ferallitic soil, because it contains ten times more free iron than the podzol [fr

  14. Procedures for accurately diluting and dispensing radioactive solutions

    International Nuclear Information System (INIS)

    1975-01-01

    The technique currently used by various laboratories participating in international comparisons of radioactivity measurements are surveyed and recommendations for good laboratory practice established. Thus one describes, for instance, the preparation of solutions, dilution techniques, the use of 'pycnometers', weighing procedures (including buyoancy correction), etc. It should be possible to keep random and systematic uncertainties below 0.1% of the final result

  15. Application of the deuterated retinol dilution technique to detect changes in hepatic retinol reserves in infants who receive high dose vitamin A supplements

    International Nuclear Information System (INIS)

    Penny, M.; Lanata, C.; Butron, B.; Haskell, M.; Brown, K.

    1997-01-01

    The purpose of this pilot study is to determine whether the deuterated retinol dilution technique can detect changes in hepatic vitamin A reserves in Peruvian infants in response to supplementation with vitamin A palmitate. Approximately 40 infants, 9 months of age, will be recruited for the study and randomly assigned to four treatment groups. Hepatic vitamin A reserves will be estimated using the deuterated retinol dilution technique before and after administration of a single supplement containing either 0, 7.5, 15, or 30 mg RE as retinyl palmitate in corn oil. Mean hepatic vitamin A reserves will be calculated based on the plasma isotopic ratio of d4-retinol:retinol as per Furr, et. al. Hepatic vitamin A reserves will be compared within groups before and after supplementation, and among the four groups. The mean change in hepatic vitamin A reserves across the four treatment groups will be examined in relation to the amount of vitamin A supplement administered, using regression analysis. The results of the pilot study will provide information on the size and variation of hepatic vitamin A reserves in 9-month old Peruvian infants. This information will be useful for calculating samples sizes to evaluate vitamin A intervention strategies by estimating changes in hepatic vitamin A stores in this age group, using the DRD technique. (author)

  16. Application of the deuterated retinol dilution technique to detect changes in hepatic retinol reserves in infants who receive high dose vitamin A supplements

    Energy Technology Data Exchange (ETDEWEB)

    Penny, M; Lanata, C; Butron, B [Instituto de Investigacion Nutricional, Lima (Peru); Haskell, M; Brown, K [Programme in International Nutrition, Univ. of California, Davis, CA (United States)

    1998-12-31

    The purpose of this pilot study is to determine whether the deuterated retinol dilution technique can detect changes in hepatic vitamin A reserves in Peruvian infants in response to supplementation with vitamin A palmitate. Approximately 40 infants, 9 months of age, will be recruited for the study and randomly assigned to four treatment groups. Hepatic vitamin A reserves will be estimated using the deuterated retinol dilution technique before and after administration of a single supplement containing either 0, 7.5, 15, or 30 mg RE as retinyl palmitate in corn oil. Mean hepatic vitamin A reserves will be calculated based on the plasma isotopic ratio of d4-retinol:retinol as per Furr, et. al. Hepatic vitamin A reserves will be compared within groups before and after supplementation, and among the four groups. The mean change in hepatic vitamin A reserves across the four treatment groups will be examined in relation to the amount of vitamin A supplement administered, using regression analysis. The results of the pilot study will provide information on the size and variation of hepatic vitamin A reserves in 9-month old Peruvian infants. This information will be useful for calculating samples sizes to evaluate vitamin A intervention strategies by estimating changes in hepatic vitamin A stores in this age group, using the DRD technique. (author). 12 refs, 3 figs.

  17. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  18. Molecular analysis of two mouse dilute locus deletion mutations: Spontaneous dilute lethal20J and radiation-induced dilute prenatal lethal Aa2 alleles

    International Nuclear Information System (INIS)

    Strobel, M.C.; Seperack, P.K.; Copeland, N.G.; Jenkins, N.A.

    1990-01-01

    The dilute (d) coat color locus of mouse chromosome 9 has been identified by more than 200 spontaneous and mutagen-induced recessive mutations. With the advent of molecular probes for this locus, the molecular lesion associated with different dilute alleles can be recognized and precisely defined. In this study, two dilute mutations, dilute-lethal20J (dl20J) and dilute prenatal lethal Aa2, have been examined. Using a dilute locus genomic probe in Southern blot analysis, we detected unique restriction fragments in dl20J and Aa2 DNA. Subsequent analysis of these fragments showed that they represented deletion breakpoint fusion fragments. DNA sequence analysis of each mutation-associated deletion breakpoint fusion fragment suggests that both genomic deletions were generated by nonhomologous recombination events. The spontaneous dl20J mutation is caused by an interstitial deletion that removes a single coding exon of the dilute gene. The correlation between this discrete deletion and the expression of all dilute-associated phenotypes in dl20J homozygotes defines the dl20J mutation as a functional null allele of the dilute gene. The radiation-induced Aa2 allele is a multilocus deletion that, by complementation analysis, affects both the dilute locus and the proximal prenatal lethal-3 (pl-3) functional unit. Molecular analysis of the Aa2 deletion breakpoint fusion fragment has provided access to a previously undefined gene proximal to d. Initial characterization of this new gene suggests that it may represent the genetically defined pl-3 functional unit

  19. Individual Tracer Atoms in an Ultracold Dilute Gas

    Science.gov (United States)

    Hohmann, Michael; Kindermann, Farina; Lausch, Tobias; Mayer, Daniel; Schmidt, Felix; Lutz, Eric; Widera, Artur

    2017-06-01

    We report on the experimental investigation of individual Cs atoms impinging on a dilute cloud of ultracold Rb atoms with variable density. We study the relaxation of the initial nonthermal state and detect the effect of single collisions which has so far eluded observation. We show that, after few collisions, the measured spatial distribution of the tracer atoms is correctly described by a Langevin equation with a velocity-dependent friction coefficient, over a large range of Knudsen numbers. Our results extend the simple and effective Langevin treatment to the realm of light particles in dilute gases. The experimental technique developed opens up the microscopic exploration of a novel regime of diffusion at the level of individual collisions.

  20. Hybridizing pines with diluted pollen

    Science.gov (United States)

    Robert Z. Callaham

    1967-01-01

    Diluted pollens would have many uses by the tree breeder. Dilutions would be particularly advantageous in making many controlled pollinations with a limited amount of pollen. They also would be useful in artificial mass pollinations of orchards or single trees. Diluted pollens might help overcome troublesome genetic barriers to crossing. Feasibility o,f using diluted...

  1. Development of isotope dilution-liquid chromatography/mass spectrometry combined with standard addition techniques for the accurate determination of tocopherols in infant formula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joonhee; Jang, Eun-Sil; Kim, Byungjoo, E-mail: byungjoo@kriss.re.kr

    2013-07-17

    Graphical abstract: -- Highlights: •ID-LC/MS method showed biased results for tocopherols analysis in infant formula. •H/D exchange of deuterated tocopherols in sample preparation was the source of bias. •Standard addition (SA)-ID-LC/MS was developed as an alternative to ID-LC/MS. •Details of calculation and uncertainty evaluation of the SA-IDMS were described. •SA-ID-LC/MS showed a higher-order metrological quality as a reference method. -- Abstract: During the development of isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) for tocopherol analysis in infant formula, biased measurement results were observed when deuterium-labeled tocopherols were used as internal standards. It turned out that the biases came from intermolecular H/D exchange and intramolecular H/D scrambling of internal standards in sample preparation processes. Degrees of H/D exchange and scrambling showed considerable dependence on sample matrix. Standard addition-isotope dilution mass spectrometry (SA-IDMS) based on LC/MS was developed in this study to overcome the shortcomings of using deuterium-labeled internal standards while the inherent advantage of isotope dilution techniques is utilized for the accurate recovery correction in sample preparation processes. Details of experimental scheme, calculation equation, and uncertainty evaluation scheme are described in this article. The proposed SA-IDMS method was applied to several infant formula samples to test its validity. The method was proven to have a higher-order metrological quality with providing very accurate and precise measurement results.

  2. Phosphorus Use Efficiency by Brazilian Common Bean Genotypes Assessed by the {sup 32}P Dilution Technique

    Energy Technology Data Exchange (ETDEWEB)

    Franzini, V. I. [Brazilian Agricultural Research Corporation, EMBRAPA-Amazonia Oriental, Belem, PA (Brazil); Muraoka, T. [Center for Nuclear Energy in Agriculture, University of Sao Paulo, Piracicaba, SP (Brazil); Adu-Gyamfi, J. J [International Atomic Energy Agency, Vienna (Austria); Lynch, J. P. [Pennsylvania State University, University Park, PA (United States)

    2013-11-15

    The objectives of this work were to identify the most efficient common bean (Phaseolus vulgaris L.) genotypes on phosphorus (P) utilization, and verify if P from the seed affects the classification of common bean genotypes on P uptake efficiency when the {sup 32}P isotopic dilution technique is used. The experiment was conducted in a greenhouse, and plants were grown in pots with surface samples of a dystrophic Typic Haplustox. The treatments consisted of 50 common bean genotypes and two standard plant species, efficient or inefficient in P uptake. The results were assessed through correlation and cluster analysis (multivariate). Sangue de Boi, Rosinha, Thayu, Grafite, Horizonte, Pioneiro and Jalo Precoce common bean genotypes were the most efficient on P uptake, and Carioca 80, CNF 10, Perola, IAPAR 31, Roxao EEP, Apore, Pioneiro, Pontal, Timbo and Ruda were the most efficient in P utilization. The P derived from seed influences the identification of common bean genotypes for P uptake efficiency. (author)

  3. Phase diagrams of diluted transverse Ising nanowire

    International Nuclear Information System (INIS)

    Bouhou, S.; Essaoudi, I.; Ainane, A.; Saber, M.; Ahuja, R.; Dujardin, F.

    2013-01-01

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J cs exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given

  4. Radiotracer technique to quantify change in filtration velocity as a measure of dilution effect by artificial recharge in an arsenic infested aquifer at Ashoknagar, Habra - II block, 24 Paragana district, West Bengal

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2004-01-01

    Radioisotopes are frequently employed as tracers for various applications in industry, agricultural, medicine and hydrology. In hydrology, radiotracers are commonly applied to investigate several hydrological parameters of aquifers such as hydraulic conductivity, groundwater velocity and direction of flow etc. They impart valuable insight into the understanding of the hydrological systems. Application of radioisotopes in determination of groundwater flow velocity is now a well established technique. In this paper, groundwater filtration velocity was determined in an arsenic infested alluvium aquifer at Ashoknagar, Habra, West Bengal for determining the dilution effect due to arsenic free water. In some parts of West Bengal, generally shallow aquifers up to 80 m deep are contaminated due to geogenic arsenic. Researchers have different views about origin and mobility of arsenic in the groundwaters of West Bengal. For the removal of Arsenic from the groundwater various methods have been suggested and implemented such as ion-exchange, co-precipitation, adsorption, membrane separation and dilution etc. Dilution of the Arsenic concentration by artificial recharge of arsenic free water from the constructed pits in the contaminated aquifer is one such simple method. Efficacy of this method was studied by measuring filtration velocity in the contaminated aquifer at the Ashoknagar, Habra - II Block, North 24 Paragana district, West Bengal. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater. Point dilution technique in a single well was applied. Filtration velocity provided relevant information about the arsenic dilution in the groundwater by the artificial recharge and its value will be used as a model parameter. (author)

  5. Quantification of Labile Soil Mercury by Stable Isotope Dilution Techniques

    Science.gov (United States)

    Shetaya, Waleed; Huang, Jen-How; Osterwalder, Stefan; Alewell, Christine

    2016-04-01

    Mercury (Hg) is a toxic element that can cause severe health problems to humans. Mercury is emitted to the atmosphere from both natural and anthropogenic sources and can be transported over long distances before it is deposited to aquatic and terrestrial environments. Aside from accumulation in soil solid phases, Hg deposited in soils may migrate to surface- and ground-water or enter the food chain, depending on its lability. There are many operationally-defined extraction methods proposed to quantify soil labile metals. However, these methods are by definition prone to inaccuracies such as non-selectivity, underestimation or overestimation of the labile metal pool. The isotopic dilution technique (ID) is currently the most promising method for discrimination between labile and non-labile metal fractions in soil with a minimum disturbance to soil-solid phases. ID assesses the reactive metal pool in soil by defining the fraction of metal both in solid and solution phases that is isotopically-exchangeable known as the 'E-value'. The 'E-value' represents the metal fraction in a dynamic equilibrium with the solution phase and is potentially accessible to plants. This is carried out by addition of an enriched metal isotope to soil suspensions and quantifying the fraction of metal that is able to freely exchange with the added isotope by measuring the equilibrium isotopic ratio by ICP-MS. E-value (mg kg-1) is then calculated as follows: E-Value = (Msoil/ W) (CspikeVspike/ Mspike) (Iso1IAspike -Iso2IAspikeRss / Iso2IAsoil Rss - Iso1IAsoil) where M is the average atomic mass of the metal in the soil or the spike, W is the mass of soil (kg), Cspike is the concentration of the metal in the spike (mg L-1), Vspike is the volume of spike (L), IA is isotopic abundance, and Rss is the equilibrium ratio of isotopic abundances (Iso1:Iso2). Isotopic dilution has been successfully applied to determine E-values for several elements. However, to our knowledge, this method has not yet

  6. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  7. Analysis of structure and defects in thin silicon films deposited from hydrogen diluted silane

    International Nuclear Information System (INIS)

    Elzakker, G. van; Nadazdy, V.; Tichelaar, F.D.; Metselaar, J.W.; Zeman, M.

    2006-01-01

    Thin silicon layers have been deposited from silane diluted with hydrogen. The dilution ratio R (R = [H 2 ]/[SiH 4 ]) has been varied between R = 0 and R = 40. The structural properties of Si:H films have been studied using transmission electron microscopy imaging and Raman spectroscopy. The phase evolution from the amorphous phase into the mixed and eventually microcrystalline phase strongly depends on the hydrogen dilution. The initiation of the microcrystalline growth occurs between R = 20 and R = 25. The phase transition becomes more abrupt with increasing hydrogen dilution. Optoelectronic properties of the layers have been determined. Increasing hydrogen dilution results in films with increasing effective defect density and Urbach energy, which is related to inhomogeneous growth. The charge deep-level transient spectroscopy technique (Q-DLTS) was applied for the first time on hydrogen diluted thin silicon films in order to investigate the energy distribution of the defect states in these layers as a function of the dilution ratio R. The Q-DLTS spectra indicate a difference in defect-state distribution when the films evolve from the amorphous phase into the microcrystalline phase

  8. Phase diagrams of diluted transverse Ising nanowire

    Energy Technology Data Exchange (ETDEWEB)

    Bouhou, S.; Essaoudi, I. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Ainane, A., E-mail: ainane@pks.mpg.de [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Saber, M. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Ahuja, R. [Condensed Matter Theory Group, Department of Physics and Astronomy, Uppsala University, 75120 Uppsala (Sweden); Dujardin, F. [Laboratoire de Chimie et Physique des Milieux Complexes (LCPMC), Institut de Chimie, Physique et Matériaux (ICPM), 1 Bd. Arago, 57070 Metz (France)

    2013-06-15

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J{sub cs} exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given.

  9. Brewing Bokashi: Strengthening Student Skills in Dilution Theory through Fermentation Analysis

    Directory of Open Access Journals (Sweden)

    Robert E. Zdor

    2016-05-01

    Full Text Available One of the basic microbiological techniques that students should master is that of using dilution theory to calculate the levels of bacteria in a fluid. This tip reports on using a rice water-milk fermentation mixture termed Bokashi as an easily implemented exercise in the basic microbiological lab to give students multiple opportunities to use dilution theory. Due to the shifts in bacterial community composition over time, a variety of microbes can be cultured using selective and nonselective media. Microscopic observation and the use of GEN III microplates to determine the collective phenotypic pattern of the mixture both give additional opportunities for students to hone their skills in bacterial analysis. Due to the decrease in the pH of the mixture over time, the notion of acid tolerance in bacteria can be explored and assessed using the microplate. By performing multiple rounds of serial dilutions and spread plating, students can practice their skill at using dilution theory several times over the course of the exercise.

  10. Optical spacing effect in organic photovoltaic cells incorporating a dilute acceptor layer

    Energy Technology Data Exchange (ETDEWEB)

    Menke, S. Matthew; Lindsay, Christopher D.; Holmes, Russell J. [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-06-16

    The addition of spacing layers in organic photovoltaic cells (OPVs) can enhance light absorption by optimizing the spatial distribution of the incident optical field in the multilayer structure. We explore the optical spacing effect in OPVs achieved using a diluted electron acceptor layer of C{sub 60}. While optical spacing is often realized by optimizing buffer layer thickness, we find that optical spacing via dilution leads to cells with similar or enhanced photocurrent. This is observed despite a smaller quantity of absorbing molecules, suggesting a more efficient use of absorbed photons. In fact, dilution is found to concentrate optical absorption near the electron donor-acceptor interface, resulting in a marked increase in the exciton diffusion efficiency. Contrasting the use of changes in thickness to engineer optical absorption, the use of dilution does not significantly alter the overall thickness of the OPV. Optical spacing via dilution is shown to be a viable alternative to more traditional optical spacing techniques and may be especially useful in the continued optimization of next-generation, tandem OPVs where it is important to minimize competition for optical absorption between individual sub-cells.

  11. Optical spacing effect in organic photovoltaic cells incorporating a dilute acceptor layer

    International Nuclear Information System (INIS)

    Menke, S. Matthew; Lindsay, Christopher D.; Holmes, Russell J.

    2014-01-01

    The addition of spacing layers in organic photovoltaic cells (OPVs) can enhance light absorption by optimizing the spatial distribution of the incident optical field in the multilayer structure. We explore the optical spacing effect in OPVs achieved using a diluted electron acceptor layer of C 60 . While optical spacing is often realized by optimizing buffer layer thickness, we find that optical spacing via dilution leads to cells with similar or enhanced photocurrent. This is observed despite a smaller quantity of absorbing molecules, suggesting a more efficient use of absorbed photons. In fact, dilution is found to concentrate optical absorption near the electron donor-acceptor interface, resulting in a marked increase in the exciton diffusion efficiency. Contrasting the use of changes in thickness to engineer optical absorption, the use of dilution does not significantly alter the overall thickness of the OPV. Optical spacing via dilution is shown to be a viable alternative to more traditional optical spacing techniques and may be especially useful in the continued optimization of next-generation, tandem OPVs where it is important to minimize competition for optical absorption between individual sub-cells.

  12. A New Flow Control Technique Using Diluted Epinephrine in the N-butyl-2-cyanoacrylate Embolization of Visceral Artery Pseudoaneurysms Secondary to Chronic Pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Yamagami, Takuji [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan); Takeuchi, Yoshito [National Cancer Center, Division of Diagnostic Radiology (Japan); Matsumoto, Tomohiro; Asai, Shunsuke; Masui, Koji [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Sato, Hideki [Japan Red Cross Kyoto Daiichi Hospital, Department of Gastroenterology (Japan); Taniguchi, Fumihiro [Japan Red Cross Kyoto Daiichi Hospital, Department of Surgery (Japan); Sato, Osamu [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan)

    2012-08-15

    Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.

  13. Mössbauer Studies of dilute Magnetic Semiconductors

    CERN Multimedia

    Gislason, H P; Debernardi, A; Dlamini, W B

    2002-01-01

    The recent discovery of (dilute) magnetic semiconductors with wide band gaps, e.g. GaN, ZnO and other oxides, having Curie temperatures, T$_{\\textrm{c}}$, well above room temperature, has prompted extraordinary experimental and theoretical efforts to understand, control and exploit this unexpected finding not least in view of the obvious potential of such materials for the fabrication of "spin-(elec)tronic" or magneto-optic devices. Ferromagnetism (FM) was achieved mostly by doping with dilute 3d transition metal impurities, notably Mn, Fe, and Co (in \\% concentrations), during growth or by subsequent ion implantation. However, it is fair to state that experimentally the conditions for the occurrence of ferro-, antiferro- or paramagnetism with these impurities are not yet controlled as generally at least two conflicting forms of magnetism or none have been reported for each system - albeit often produced by different techniques. Theory is challenged as "conventional" models seem to fail and no generally accep...

  14. The phase diagrams of the site-diluted spin-1/2 Ising superlattice

    International Nuclear Information System (INIS)

    Saber, A.; Essaoudi, I.; Ainane, A.; Dujardin, F.; Saber, M.; Stebe, B.

    1998-08-01

    Using the effective field theory with a probability distribution technique that accounts for the single-site spin correlations, the critical behavior of a diluted spin-1/2 Ising superlattice consisting of two different ferromagnet materials is examined. The critical temperature of the system is studied as a function of the thickness of the constituents in a unit cell, the concentration of magnetic atoms, and the exchange interactions in each material. It is shown that the properties of the diluted system are different from those of the corresponding pure system. (author)

  15. Use of image analysis for monitoring the dilution of Physalis peruviana pulp

    Directory of Open Access Journals (Sweden)

    Silvana Licodiedoff

    2013-06-01

    Full Text Available The aim of this work was to develop linear models using the image analysis coupled with density measurements to monitor the dilution of the Physalis juice in the concentrations ranging from 0 to 100% in mass of juice pulp. A sample corresponding to 20% in the mass of juice pulp was for validating purposes and a prediction of 19.9±0.3%. The models with three parameters showed the best predictions, providing this technique with a promising future for the monitoring the dilution of fruit juices.

  16. Diluted Ising spin 1/2 lattice with an arbitrary coordination number

    International Nuclear Information System (INIS)

    Bach Thanh Cong; El Amraoui, Y.

    1993-01-01

    A useful representation for the Callen identity in the case of spin 1/2 is introduced by a simple technique. The phase diagrams, percolation problems of the diluted Ising lattice with arbitrary coordination number z are also discussed. (author). 12 refs, 5 figs

  17. Dilution and separation of solids and liquids of broiler litter for supply of digester

    Energy Technology Data Exchange (ETDEWEB)

    Aires, Airon Magno; Lucas Junior, Jorge de; Xavier, Cristiane de Almeida Neves; Miranda, Adelia Pereira; Fukayama, Ellen Hatsumi [Universidade Estadual Paulista (FCAV/UNESP), Jaboticabal, SP (Brazil). Fac. de Ciencias Agrarias e Veterinarias

    2008-07-01

    The solid separation techniques indicate that it can promote a support in anaerobic biological process. This trial was realized in FCAV-UNESP, Jaboticabal, Brazil, in Rural Engineering Department. For this trial two tests were developed, using broiler litter water diluted and separated in a 3mm mesh screen: the treatments consisted in (1kg) broiler litter diluted in (2kg) of water, (1kg) broiler litter and (4kg) water, (1kg) broiler litter diluted in (6kg) of water, (1kg) broiler litter and (8kg) of water, (1kg) broiler litter diluted in (10kg) of water, (1kg) broiler litter and (12kg) water and (1kg) broiler litter diluted in (14kg) of water. Total solids (TS), solid and liquid fraction and biogas production were estimated. There were no significant differences related to solid fraction retained in screen. As the broiler litter became more diluted, a raise in the liquid fractions quantities was observed, ranging from 20.9 to 89.4% of the total diluted waste. Biogas production potentials ranged from 0.2364 to 0.4666 m{sup 3} of biogas by 100kg of liquid fraction. Organic carbon numbers ranged from 0.21 to 0.47kg by 100kg of liquid fraction and 5.36 to 6.18kg by 100kg of solid fraction. The highest values obtained for this element in liquid fractions dilutions were 2:1 and 6:1 with 0.46 and 0.47kg by 100kg respectively. The separation of liquid and solid fraction of broiler litter was viable in the smaller dilutions, because those guarantee a reduction in the anaerobic digester implementation costs and dilution water economy. Solid fraction has potential for composting, mainly in a great scale production. (author)

  18. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  19. Radioisotope dilution technique for determination of vitamin B12 in foods

    International Nuclear Information System (INIS)

    Casey, P.J.; Speckman, K.R.; Ebert, F.J.; Hobbs, W.E.

    1982-01-01

    A radioisotope dilution (RID) method for the determination of vitamin B 12 is presented. The method combines a standard extraction procedure (AOAC 43.108, 12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products. Recovery studies on both groups yielded average recoveries of 98.1 and 95.8%, respectively. Reproducibility data generated from replicate analysis on both groups gave a relative standard deviation of 6.9% for the fortified group and 9.2% for the unfortified group. For the samples studied, the mean vitamin B 12 content determined by the RID method was 8.01 μ/100 g vs a mean of 7.54 μg/100 g by the AOAC microbiological method; the correlation coefficient was r = 0.983

  20. Isotope-dilution analyses of the metallic elements

    International Nuclear Information System (INIS)

    Chastagner, P.

    1982-01-01

    The isotope-dilution mass spectroscopy (IDMS) technique has proven to be to be a reliable, versatile analytical tool. Its applications seem to be limited only by the ingenuity of the investigator. Among its advantages are: small sample size; general applicability; precision and accuracy; dynamic range; simplified chemistry; determination is fixed at the time and place of isotopic homogenization. The last listed item is especially important for nuclear safeguards and processes where inventories are critical. IDMS is now a routine analytical technique in geochemical and nuclear laboratories, and in many environmental laboratories. Microgram and nanogram samples are normally used, frequently with automatic mass spectrometers, in many of these routine applications. More advanced techniques permit picogram and sub picogram samples to be analyzed, and spike to sample ratios can range from 1:1 to 1:10 12 with detection limits at attogram levels for some elements. 3 figures, 3 tables

  1. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    International Nuclear Information System (INIS)

    Pereira, L M C

    2017-01-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials. (topical review)

  2. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    Science.gov (United States)

    Pereira, L. M. C.

    2017-10-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials.

  3. Isotope dilution mass spectrometry for nuclear material accountability measurements: dreams and reality

    International Nuclear Information System (INIS)

    Deron, S.; )

    1996-01-01

    Gravimetry, titration, coulometry and isotope dilution mass spectrometry are alternative techniques which can be used to obtain elemental assays of the desirable accuracy. The communication briefly describes the characteristics of the procedure and summarizes a wealth of experience accumulated during actual accountability verification activities

  4. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  5. A comparative study on the production rates of VFA and bacteria in the rumen of buffalo and goat estimated by isotope dilution technique

    International Nuclear Information System (INIS)

    Verma, D.N.; Mehra, U.R.; Singh, U.B.; Ranjhan, S.K.

    1977-01-01

    Digestibility trials were conducted on Murrah buffaloes and Barbari goats with rumen cannulae in the rumen to determine the digestibility of the feed constituents and the production rates of bacteria and total VFA were estimated in the rumen by isotope dilution technique. The bacterial cells growth in the rumen was more in goats than buffaloes when fed ad libitum and calculated on equal feed intake, where as, in buffaloes fed on restricted diet equal to the goats the production of bacteria and VFA were higher. Goats converted 54.04 percent of their dietary nitrogen into microbial nitrogen which was more than twice of buffaloes. (author)

  6. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  7. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  8. Dilution Refrigeration of Multi-Ton Cold Masses

    CERN Document Server

    Wikus, P; CERN. Geneva

    2007-01-01

    Dilution refrigeration is the only means to provide continuous cooling at temperatures below 250 mK. Future experiments featuring multi-ton cold masses require a new generation of dilution refrigeration systems, capable of providing a heat sink below 10 mK at cooling powers which exceed the performance of present systems considerably. This thesis presents some advances towards dilution refrigeration of multi-ton masses in this temperature range. A new method using numerical simulation to predict the cooling power of a dilution refrigerator of a given design has been developed in the framework of this thesis project. This method does not only allow to take into account the differences between an actual and an ideal continuous heat exchanger, but also to quantify the impact of an additional heat load on an intermediate section of the dilute stream. In addition, transient behavior can be simulated. The numerical model has been experimentally verified with a dilution refrigeration system which has been designed, ...

  9. Hydrogenated dilute nitride semiconductors theory, properties, and applications

    CERN Document Server

    Ciatto, Gianluca

    2015-01-01

    ""The electrical and optical properties of the technologically and scientifically important dilute nitride semiconductors are strongly influenced by the introduction of atomic hydrogen. This volume is an excellent summary and resource for the most recent understanding of experimental results and state-of-the-art theoretical studies of the formation, reversibility, and microscopic structure of nitrogen-hydrogen complexes in these materials. The book details how a wide variety of experimental techniques have provided a detailed understanding of the role of hydrogen. It is the premier sourc

  10. Genetic variability in dinitrogen fixation between cowpea [Vigna unguiculata (L.) Walp] cultivars determined using the nitrogen-15 isotope dilution technique

    International Nuclear Information System (INIS)

    Ndiaye, M.A.F.; Spencer, M.M.; Gueye, M.

    2000-01-01

    N fixed in 16 cultivars of cowpea [Vigna unguiculata (L.) Walp] inoculated with effective Bradyrhizobium strains collected from the West African MIRCEN culture collection was measured by 15N isotope dilution technique. In all plant parts, significant differences in the percentage of N derived from the atmosphere (%Ndfa) and the amount of Ndfa occurred between the cultivars. Ndoute variety exhibited the highest %Ndfa (74.33% in shoots; 60.90% in roots) and accumulated more fixed N (960 mg N plant–1 and 38 mg N plant–1 in shoots and roots, respectively). Therefore this cultivar should be selected as the highest N-fixing cowpea cultivar. It also should be used in a breeding programme to contribute to the development of cultivars that could stimulate an intensive use of cowpea in many different cropping systems in Africa with a view to maintaining soil fertility. (Authors)

  11. Further development of IDGS: Isotope dilution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Li, T.K.; Parker, J.L.; Kuno, Y.; Sato, S.; Kamata, M.; Akiyama, T.

    1991-01-01

    The isotope dilution gamma-ray spectrometry (IDGS) technique for determining the plutonium concentration and isotopic composition of highly radioactive spent-fuel dissolver solutions has been further developed. Both the sample preparation and the analysis have been improved. The plutonium isotopic analysis is based on high-resolution, low-energy gamma-ray spectrometry. The plutonium concentration in the dissolver solutions then is calculated from the measured isotopic differences among the spike, the dissolver solution, and the spiked dissolver solution. Plutonium concentrations and isotopic compositions of dissolver solutions analyzed from this study agree well with those obtained by traditional isotope dilution mass spectrometry (IDMS) and are consistent with the first IDGS experimental result. With the current detector efficiency, sample size, and a 100-min count time, the estimated precision is ∼0.5% for 239 Pu and 240 Pu isotopic analyses and ∼1% for the plutonium concentration analysis. 5 refs., 2 figs., 7 tabs

  12. Field ionization mass spectrometry (FIMS) applied to tracer studies and isotope dilution analysis

    International Nuclear Information System (INIS)

    Anbar, M.; Heck, H.d'A.; McReynolds, J.H.; St John, G.A.

    1975-01-01

    The nonfragmenting nature of field ionization mass spectrometry makes it a preferred technique for the isotopic analysis of multilabeled organic compounds. The possibility of field ionization of nonvolatile thermolabile materials significantly extends the potential uses of this technique beyond those of conventional ionization methods. Multilabeled tracers may be studied in biological systems with a sensitivity comparable to that of radioactive tracers. Isotope dilution analysis may be performed reliably by this technique down to picogram levels. These techniques will be illustrated by a number of current studies using multilabeled metabolites and drugs. The scope and limitations of the methodology are discussed

  13. Hemodiafiltration using pre-dilutional on-line citrate dialysate: A new technique for regional citrate anticoagulation: A feasibility study

    Directory of Open Access Journals (Sweden)

    Radhouane Bousselmi

    2015-01-01

    Full Text Available A prospective, observational, feasibility study was carried out on four patients with end-stage renal failure undergoing bicarbonate hemodialysis to study the feasibility of an on-line hemodiafiltration technique using a citrate dialysate with pre-dilutional infusion of citrate as a technique for regional citrate anticoagulation. All patients had contraindication to systemic heparin anticoagulation. The dialysis technique consisted of an on-line hemodiafiltration with a citrate dialysate without calcium using a Fresenius 4008S dialysis machine and Fresenius Polysulfone F60 dialyzers. The infusion solution was procured directly from the dialysate and was infused into the arterial line. To avoid the risk of hypocalcemia, calcium gluconate was infused to the venous return line. The study was carried out in two stages. During the first stage, the citrate infusion rate was 80 mL/min and the calcium infusion rate was 9 mmol/h. At the second stage, the rates were 100 mL/min and 11 mmol/h, respectively. The primary endpoint of this study was the incidence of thrombosis in the extracorporeal blood circuit and/or the dialyzer. A total of 78 sessions were conducted. All the sessions were well tolerated clinically and there were no major incidents in any of the four patients. At the first stage of the study, there were five incidences of small clots in the venous blood chamber, an incidence of extracorporeal blood circuit thrombosis of 12.5%. At the second stage of the study, no cases of extracorporeal blood circuit or dialyzer thrombosis were noted. Hemodiafiltration with on-line citrate dialysate infusion to the arterial line is safe and allows an effective regional anticoagulation of the extracorporeal blood circuit without the need for systemic anticoagulation.

  14. Guideline on Isotope Dilution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Amy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-19

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. This method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.

  15. Development of the Melt-Dilute Treatment Technology for Al-Based DOE Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Peacock, H.B.; Adams, T.M.; Iyer, N.C.

    1998-09-01

    Spent foreign and domestic research reactor fuel assemblies will be sent to Savannah River Site and prepared for interim and eventual geologic storage. Many of the fuel plates have been made with high enriched uranium, and during long term storage, the integrity of the fuel maybe effected if the canister is breached. To reduce the potential for criticality, proliferation, and reduce storage volume, a new treatment technology called melt-dilute is being developed at SRS. The technique will melt the spent fuel assemblies and will dilute the isotopic content to below 20%. The process is simple and versatile

  16. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  17. Theoretical modeling of diluted antiferromagnetic systems

    International Nuclear Information System (INIS)

    Pozo, J; Elgueta, R; Acevedo, R

    2000-01-01

    Some magnetic properties of a Diluted Antiferromagnetic System (DAFS) are studied. The model of the two sub-networks for antiferromagnetism is used and a Heisenberg Hamiltonian type is proposed, where the square operators are expressed in terms of boson operators with the approach of spin waves. The behavior of the diluted system's fundamental state depends basically on the competition effect between the anisotropy field and the Weiss molecular field. The approach used allows the diluted system to be worked for strong anisotropies as well as when these are very weak

  18. Acetone and acetaldehyde determination in tomato juice by isotopic dilution

    International Nuclear Information System (INIS)

    Piva, M.-T.; Crouzet, J.

    1977-01-01

    Acetone and acetaldehyde content of tomato juice were determined by isotope dilution techniques. The juice is added to 14 C labelled compounds, carried along by nitrogen at low pressure. The mixture of 2.4 dinitrophenylhydrazones obtained from volatile compounds is separated by thin layer chromatography on silica gel and then on alumina. A determination of radioactivity and concentration of acetone and acetaldehyde 2,4 dinitrophenylhydrazones obtained after separation and elution allow to calculate the content of these two compounds in the initial product with the same sample. This technique could be used for determination of methanol and ethanol after transformation in 3,5 dinitrobenzoates [fr

  19. Comparison of dilution factors for German wastewater treatment plant effluents in receiving streams to the fixed dilution factor from chemical risk assessment.

    Science.gov (United States)

    Link, Moritz; von der Ohe, Peter C; Voß, Katharina; Schäfer, Ralf B

    2017-11-15

    Incomplete removal during wastewater treatment leads to frequent detection of compounds such as pharmaceuticals and personal care products in municipal effluents. A fixed standard dilution factor of 10 for effluents entering receiving water bodies is used during the exposure assessment of several chemical risk assessments. However, the dilution potential of German receiving waters under low flow conditions is largely unknown and information is sparse for other European countries. We calculated dilution factors for two datasets differing in spatial extent and wastewater treatment plant (WWTP) size: a national dataset comprising 1225 large WWTPs in Central and Northern Germany and a federal dataset for 678 WWTPs of a single state in Southwest Germany. We found that the fixed factor approach overestimates the dilution potential of 60% and 40% of receiving waters in the national and the federal dataset, with median dilution factors of 5 and 14.5, respectively. Under mean flow conditions, 8% of calculated dilution factors were below 10, with a median dilution factor of 106. We also calculated regional dilution factors that accounted for effluent inputs from upstream WWTPs. For the national and the federal dataset, 70% and 60% of calculated regional dilution factors fell below 10 under mean low flow conditions, respectively. Decrease of regional dilution potential in small receiving streams was mainly driven by the next WWTP upstream with a 2.5 fold drop of median regional dilution factors. Our results show that using the standard dilution factor of 10 would result in the underestimation of environmental concentrations for authorised chemicals by a factor of 3-5 for about 10% of WWTPs, especially during low flow conditions. Consequently, measured environmental concentrations might exceed predicted environmental concentrations and ecological risks posed by effluents could be much higher, suggesting that a revision of current risk assessment practices may be required

  20. Dilute acid/metal salt hydrolysis of lignocellulosics

    Science.gov (United States)

    Nguyen, Quang A.; Tucker, Melvin P.

    2002-01-01

    A modified dilute acid method of hydrolyzing the cellulose and hemicellulose in lignocellulosic material under conditions to obtain higher overall fermentable sugar yields than is obtainable using dilute acid alone, comprising: impregnating a lignocellulosic feedstock with a mixture of an amount of aqueous solution of a dilute acid catalyst and a metal salt catalyst sufficient to provide higher overall fermentable sugar yields than is obtainable when hydrolyzing with dilute acid alone; loading the impregnated lignocellulosic feedstock into a reactor and heating for a sufficient period of time to hydrolyze substantially all of the hemicellulose and greater than 45% of the cellulose to water soluble sugars; and recovering the water soluble sugars.

  1. Determination of microquantities of silver in platinum by isotope dilution

    International Nuclear Information System (INIS)

    Yedinakova, V.; Sladkovska, Y.

    1980-01-01

    A method is described for determining microquantities of silver in platinum. It is based on isotope dilution by means of substoichiometric extraction of dithizonates with carbon tetrachloride. The determination of silver according to this technique is not interfered by zinc or gold in quantities exceeding the silver content by one order of magnitude nor by a great excess of platinum. In the presence of copper the addition of complexon is necessary. (author)

  2. Dilution thermodynamics of the biologically relevant cation mixtures

    International Nuclear Information System (INIS)

    Kaczyński, Marek; Borowik, Tomasz; Przybyło, Magda; Langner, Marek

    2014-01-01

    Graphical abstract: - Highlights: • Dilution energetics of Ca 2+ can be altered by the aqueous phase ionic composition. • Dissipated heat upon Ca 2+ dilution is drastically reduced in the K + presence. • Reduction of the enthalpy change upon Ca 2+ dilution is K + concentration dependent. • The cooperativity of Ca 2+ hydration might be of great biological relevance providing a thermodynamic argument for the specific ionic composition of the intracellular environment. - Abstract: The ionic composition of intracellular space is rigorously controlled by a variety of processes consuming large quantities of energy. Since the energetic efficiency is an important evolutional criterion, therefore the ion fluxes within the cell should be optimized with respect to the accompanying energy consumption. In the paper we present the experimental evidence that the dilution enthalpies of the biologically relevant ions; i.e. calcium and magnesium depend on the presence of monovalent cations; i.e. sodium and potassium. The heat flow generated during the dilution of ionic mixtures was measured with the isothermal titration calorimetry. When calcium was diluted together with potassium the dilution enthalpy was drastically reduced as the function of the potassium concentration present in the solution. No such effect was observed when the potassium ions were substituted with sodium ones. When the dilution of magnesium was investigated the dependence of the dilution enthalpy on the accompanying monovalent cation was much weaker. In order to interpret experimental evidences the ionic cluster formation is postulated. The specific organization of such cluster should depend on ions charges, sizes and organization of the hydration layers

  3. Validity of the tritiated thymidine method for estimating bacterial growth rates: measurement of isotope dilution during DNA synthesis

    International Nuclear Information System (INIS)

    Pollard, P.C.; Moriarty, D.J.W.

    1984-01-01

    The rate of tritiated thymidine incorporation into DNA was used to estimate bacterial growth rates in aquatic environments. To be accurate, the calculation of growth rates has to include a factor for the dilution of isotope before incorporation. The validity of an isotope dilution analysis to determine this factor was verified in experiments reported here with cultures of a marine bacterium growing in a chemostat. Growth rates calculated from data on chemostat dilution rates and cell density agreed well with rates calculated by tritiated thymidine incorporation into DNA and isotope dilution analysis. With sufficiently high concentrations of exogenous thymidine, de novo synthesis of deoxythymidine monophosphate was inhibited, thereby preventing the endogenous dilution of isoope. The thymidine technique was also shown to be useful for measuring growth rates of mixed suspensions of bacteria growing anaerobically. Thymidine was incorporated into the DNA of a range of marine pseudomonads that were investigated. Three species did not take up thymidine. The common marine cyanobacterium Synechococcus species did not incorporate thymidine into DNA

  4. Multiple-indicator dilution technique for characterization of normal and retrograde flow in once-through rat liver perfusions

    International Nuclear Information System (INIS)

    St-Pierre, M.V.; Schwab, A.J.; Goresky, C.A.; Lee, W.F.; Pang, K.S.

    1989-01-01

    The technique of normal and retrograde rat liver perfusion has been widely used to probe zonal differences in drug-metabolizing activities. The validity of this approach mandates the same tissue spaces being accessed by substrates during both normal and retrograde perfusions. Using the multiple-indicator dilution technique, we presently examine the extent to which retrograde perfusion alters the spaces accessible to noneliminated references. A bolus dose of 51Cr-labeled red blood cells, 125I-albumin, 14C-sucrose and 3H2O was injected into the portal (normal) or hepatic (retrograde) vein of rat livers perfused at 10 ml per min per liver. The outflow perfusate was serially collected over 220 sec to characterize the transit times and the distribution spaces of the labels. During retrograde perfusion, red blood cells, albumin and sucrose profiles peaked later and lower than during normal perfusion, whereas the water curves were similar. The transit times of red blood cells, albumin and sucrose were longer (p less than 0.005), whereas those for water did not change. Consequently, retrograde flow resulted in significantly larger sinusoidal blood volumes (45%), albumin Disse space (42%) and sucrose Disse space (25%) than during normal flow, whereas the distribution spaces for total and intracellular water remained unaltered. The distension of the vascular tree was confirmed by electron microscopy, by which occasional isolated foci of widened intercellular recesses and spaces of Disse were observed. Cellular ultrastructure was otherwise unchanged, and there was no difference found between normal and retrograde perfusion for bile flow rates, AST release, perfusion pressure, oxygen consumption and metabolic removal of ethanol, a substrate with flow-limited distribution, which equilibrates rapidly with cell water (hepatic extraction ratios were virtually identical: normal vs. retrograde, 0.50 vs. 0.48 at 6 to 7.4 mM input concentration)

  5. Non‐diluted seawater enhances nasal ciliary beat frequency and wound repair speed compared to diluted seawater and normal saline

    Science.gov (United States)

    Bonnomet, Arnaud; Luczka, Emilie; Coraux, Christelle

    2016-01-01

    Background The regulation of mucociliary clearance is a key part of the defense mechanisms developed by the airway epithelium. If a high aggregate quality of evidence shows the clinical effectiveness of nasal irrigation, there is a lack of studies showing the intrinsic role of the different irrigation solutions allowing such results. This study investigated the impact of solutions with different pH and ionic compositions, eg, normal saline, non‐diluted seawater and diluted seawater, on nasal mucosa functional parameters. Methods For this randomized, controlled, blinded, in vitro study, we used airway epithelial cells obtained from 13 nasal polyps explants to measure ciliary beat frequency (CBF) and epithelial wound repair speed (WRS) in response to 3 isotonic nasal irrigation solutions: (1) normal saline 0.9%; (2) non‐diluted seawater (Physiomer®); and (3) 30% diluted seawater (Stérimar). The results were compared to control (cell culture medium). Results Non‐diluted seawater enhanced the CBF and the WRS when compared to diluted seawater and to normal saline. When compared to the control, it significantly enhanced CBF and slightly, though nonsignificantly, improved the WRS. Interestingly, normal saline markedly reduced the number of epithelial cells and ciliated cells when compared to the control condition. Conclusion Our results suggest that the physicochemical features of the nasal wash solution is important because it determines the optimal conditions to enhance CBF and epithelial WRS thus preserving the respiratory mucosa in pathological conditions. Non‐diluted seawater obtains the best results on CBF and WRS vs normal saline showing a deleterious effect on epithelial cell function. PMID:27101776

  6. The use of the 15N isotope dilution technique to estimate the contribution of associated biological nitrogen fixation to the nitrogen nutrition of Paspalum notatum cv. batatais

    International Nuclear Information System (INIS)

    Boddey, R.M.; Doebereiner, Johanna

    1983-01-01

    This paper reports the results of a field experiment to investigate the use of the 15 N-dilution technique to measure the contribution of biological N 2 fixation to the N nutrition of the batatais cultivar of Paspalum notatum. The pensacola cultivar of this grass supports little associated N 2 fixation as evidenced by the low associated C 2 H 2 reduction activity and was thus used as a nonfixing control plant. The grasses were grown in 60-cm diameter concrete cylinders sunk into the soil, and the effects of four different addition rates of labelled nitrogen (NH 4 ) 2 SO 4 , were investigated. The data from seven harvests clearly demonstrated that there was a significant input of plant associated N 2 fixation to the nutrition of the batatais cultivar amounting to approximately 20 kg N ha -1 year -1 . Problems associated with the conduct of such isotope dilution experiments are discussed including the importance of using nonfixing control plants of similar growth habit, the advantages and disadvantages of growing the plants in cylinders as opposed to field plots, and the various methods of application of labelled N fertilizer

  7. Storm Sewage Dilution in Smaller Streams

    DEFF Research Database (Denmark)

    Larsen, Torben; Vestergaard, Kristian

    1987-01-01

    A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow.......A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow....

  8. Extended aroma extract dilution analysis profile of Shiikuwasha (Citrus depressa Hayata pulp essential oil

    Directory of Open Access Journals (Sweden)

    Yonathan Asikin

    2018-01-01

    Full Text Available Shiikuwasha pulp is an important raw material for producing citrus essential oils. The volatile aroma composition of pulp essential oil was evaluated using gas chromatography (GC methods, and its aroma profile was assessed using GC-olfactometry with an extended aroma extract dilution analysis (AEDA technique in regard to alterations of odor strength and sensorial perception throughout serial dilution steps. The essential oil comprised a mixture of 55 aroma compounds, including monoterpene hydrocarbon, sesquiterpene hydrocarbon, alcohol, aldehyde, ester, and oxide compounds. The predominant compounds were limonene [57.36% (4462.80 mg/100 g of pulp] and γ-terpinene [25.14% (1956.21 mg/100 g of pulp]. However, linalool was identified as one of the key aroma components providing the highest flavor dilution factor in AEDA, whilst three sesquiterpene hydrocarbons (δ-elemene, germacrene B, and bicyclosesquiphellandrene and two esters (heptyl acetate and decyl acetate had superior relative flavor activities. The extended AEDA profile identified variations in assessed odor perceptions, intensity, and duration of aroma components over dilution, whereas the 12 most odor-active compounds showed comparable odor strengths.

  9. Estimation of Optimum Dilution in the GMAW Process Using Integrated ANN-GA

    Directory of Open Access Journals (Sweden)

    P. Sreeraj

    2013-01-01

    Full Text Available To improve the corrosion resistant properties of carbon steel, usually cladding process is used. It is a process of depositing a thick layer of corrosion resistant material over carbon steel plate. Most of the engineering applications require high strength and corrosion resistant materials for long-term reliability and performance. By cladding these properties can be achieved with minimum cost. The main problem faced on cladding is the selection of optimum combinations of process parameters for achieving quality clad and hence good clad bead geometry. This paper highlights an experimental study to optimize various input process parameters (welding current, welding speed, gun angle, and contact tip to work distance and pinch to get optimum dilution in stainless steel cladding of low carbon structural steel plates using gas metal arc welding (GMAW. Experiments were conducted based on central composite rotatable design with full replication technique, and mathematical models were developed using multiple regression method. The developed models have been checked for adequacy and significance. In this study, artificial neural network (ANN and genetic algorithm (GA techniques were integrated and labeled as integrated ANN-GA to estimate optimal process parameters in GMAW to get optimum dilution.

  10. Effect of the dilution factor on 18FDG and Na18F samples for bacterial endotoxin test using PTS (portable test system)

    International Nuclear Information System (INIS)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z.

    2011-01-01

    18 FDG and Na 18 F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as 18 F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of 18 FDG and Na 18 F for PTS analysis. Two different dilution factors for 18 FDG and 1:10 for Na 18 F were essayed: 1:10 and 1:100. 18 FDG and Na 18 solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for 18 FDG and 1:10 for Na 18 F. The recovery of the product positive control was 98-12% for 18 FDG 1:100 and 104-120% for Na 18 F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for 18 FDG and Na 18 F routine endotoxin test. (author)

  11. N fixation and transfer in Maize/Cowpea and Sorghum/Cowpea inter cropping systems as determined by N-15 isotope dilution technique

    International Nuclear Information System (INIS)

    Dayatilake, G.A.; Subasinghe, S.; Senaratne, R.

    2000-01-01

    N fixation and transfer in maize/cowpea and sorghum/cowpea intercropping systems, as determined by N-15 dilution technique was studied in two field trials conducted at Bata-atha, in the dry zone of Sri Lanka. Two cvs. of cowpea i.e; Bombay and MI-35 were used in maize/cowpea intercropping system, with following combinations of treatments; maize/Bombay, maize/MI-35, Bombay (monocrop), MI-35 (monocrop) and maize (monocrop). A similar set of treatments was used in sorghum/cowpea intercropping system also. The N-15 atom excess, percentage Ndfa, total amount of N fixed, N yield and the total dry matter production were estimated. Maize/cowpea intercropping resulted in an increase in total dry matter production and total N yield compared to monocrop treatment. However the percentage Ndfa and total N fixed showed a decrease compared to monocrop stand. The percentage Ndfa was 60-65 percent monocrop while the same was 45-50 percent in intercropped treatments

  12. Cryogen-free dilution refrigerators

    International Nuclear Information System (INIS)

    Uhlig, K

    2012-01-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4 He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4 He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  13. Cryogen-free dilution refrigerators

    Science.gov (United States)

    Uhlig, K.

    2012-12-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  14. Dilute chemical decontamination program review

    International Nuclear Information System (INIS)

    Anstine, L.D.; Blomgren, J.C.; Pettit, P.J.

    1980-01-01

    The objective of the Dilute Chemical Decontamination Program is to develop and evaluate a process which utilizes reagents in dilute concentrations for the decontamination of BWR primary systems and for the maintenance of dose rates on the out-of-core surfaces at acceptable levels. A discussion is presented of the process concept, solvent development, advantages and disadvantages of reagent systems, and VNC loop tests. Based on the work completed to date it is concluded that (1) rapid decontamination of BWRs using dilute reagents is feasible; (2) reasonable reagent conditions for rapid chemical decontamination are: 0.01M oxalic acid + 0.005M citric acid, pH3.0, 90/degree/C, 0.5 to 1.0 ppm dissolved oxygen; (3) control of dissolved oxygen concentration is important, since high levels suppress the rate of decontamination and low levels allow precipitation of ferrous oxalate. 4 refs

  15. Quantifying dilution caused by execution efficiency

    Directory of Open Access Journals (Sweden)

    Taís Renata Câmara

    Full Text Available Abstract In open pit mining, dilution is not always a factor systematically analyzed and calculated. Often it is only an adjusted number, for example, calculated or even empirically determined for a certain operational condition perpetuating along time in the form of a constant applied to calculating reserves or mine planning in attendance of audit requirements. Dilution and loss are factors that should be always considered for tonnage and grade estimates. These factors are always associated and can be determined considering several particularities of the deposit and the operation itself. In this study, a methodology was determined to identify blocks adjacent to the blocks previously planned to be mined. Thus, it is possible to estimate the dilution caused by poor operating efficiency, taking into account the inability of the equipment to perfectly remove each block, respecting its limits. Mining dilution is defined as the incorporation of waste material to ore due to the operational incapacity to efficiently separate the materials during the mining process, considering the physical processes, and the operating and geometric configurations of the mining with the equipment available.

  16. Defects in dilute nitrides

    International Nuclear Information System (INIS)

    Chen, W.M.; Buyanova, I.A.; Tu, C.W.; Yonezu, H.

    2005-01-01

    We provide a brief review our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in dilute nitrides, i.e. Ga(In)NAs and Ga(Al,In)NP. Defect complexes involving intrinsic defects such as As Ga antisites and Ga i self interstitials were positively identified.Effects of growth conditions, chemical compositions and post-growth treatments on formation of the defects are closely examined. These grown-in defects are shown to play an important role in non-radiative carrier recombination and thus in degrading optical quality of the alloys, harmful to performance of potential optoelectronic and photonic devices based on these dilute nitrides. (author)

  17. Non-diluted seawater enhances nasal ciliary beat frequency and wound repair speed compared to diluted seawater and normal saline.

    Science.gov (United States)

    Bonnomet, Arnaud; Luczka, Emilie; Coraux, Christelle; de Gabory, Ludovic

    2016-10-01

    The regulation of mucociliary clearance is a key part of the defense mechanisms developed by the airway epithelium. If a high aggregate quality of evidence shows the clinical effectiveness of nasal irrigation, there is a lack of studies showing the intrinsic role of the different irrigation solutions allowing such results. This study investigated the impact of solutions with different pH and ionic compositions, eg, normal saline, non-diluted seawater and diluted seawater, on nasal mucosa functional parameters. For this randomized, controlled, blinded, in vitro study, we used airway epithelial cells obtained from 13 nasal polyps explants to measure ciliary beat frequency (CBF) and epithelial wound repair speed (WRS) in response to 3 isotonic nasal irrigation solutions: (1) normal saline 0.9%; (2) non-diluted seawater (Physiomer®); and (3) 30% diluted seawater (Stérimar). The results were compared to control (cell culture medium). Non-diluted seawater enhanced the CBF and the WRS when compared to diluted seawater and to normal saline. When compared to the control, it significantly enhanced CBF and slightly, though nonsignificantly, improved the WRS. Interestingly, normal saline markedly reduced the number of epithelial cells and ciliated cells when compared to the control condition. Our results suggest that the physicochemical features of the nasal wash solution is important because it determines the optimal conditions to enhance CBF and epithelial WRS thus preserving the respiratory mucosa in pathological conditions. Non-diluted seawater obtains the best results on CBF and WRS vs normal saline showing a deleterious effect on epithelial cell function. © 2016 The Authors International Forum of Allergy & Rhinology, published by ARSAAOA, LLC.

  18. Dynamic dilution exponent in monodisperse entangled polymer solutions

    DEFF Research Database (Denmark)

    Shahid, T.; Huang, Qian; Oosterlinck, F.

    2017-01-01

    of concentration but also depends on the molar mass of the chains. While the proposed approach successfully explains the viscoelastic properties of a large number of semi-dilute solutions of polymers in their own oligomers, important discrepancies are found for semi-dilute entangled polymers in small-molecule......We study and model the linear viscoelastic properties of several entangled semi-dilute and concentrated solutions of linear chains of different molar masses and at different concentrations dissolved in their oligomers. We discuss the dilution effect of the oligomers on the entangled long chains....... In particular, we investigate the influence of both concentration and molar mass on the value of the effective dynamic dilution exponent determined from the level of the storage plateau at low and intermediate frequencies. We show that the experimental results can be quantitatively explained by considering...

  19. Development of analytical techniques for determining rare earth elements in geological materials

    International Nuclear Information System (INIS)

    Moraes, Noemia M.P. de; Kakazu, M.H.; Iyer, S.S.

    1987-01-01

    This work presents a comparative study between instrumental neutron activation analysis, inductively coupled plasma emission spectrometry and mass spectrometric isotope dilution techniques. Some advantages and disadvantages of the techniques are presented, depending on the type of the analysis required. Emphasis in give upon mass spectrometric isotope dilution, and some procedures for the development of this technique are presented. This methodology is being established by the nuclear and isotopic geology group of the IPEN. (author) [pt

  20. Dilution and Mixing in transient velocity fields: a first-order analysis

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe, P. J.; Fiori, Aldo; Bellin, Alberto

    2017-04-01

    An appealing remediation technique is in situ oxidation, which effectiveness is hampered by difficulties in obtaining good mixing of the injected oxidant with the contaminant, particularly when the contaminant plume is contained and therefore its deformation is physically constrained. Under such conditions (i.e. containment), mixing may be augmented by inducing temporal fluctuations of the velocity field. The temporal variability of the flow field may increase the deformation of the plume such that diffusive mass flux becomes more effective. A transient periodic velocity field can be obtained by an engineered sequence of injections and extractions from wells, which may serve also as a hydraulic barrier to confine the plume. Assessing the effectiveness of periodic flows to maximize solute mixing is a difficult task given the need to use a 3D setup and the large number of possible flow configurations that should be analyzed in order to identify the optimal one. This is the typical situation in which analytical solutions, though approximated, may assist modelers in screening possible alternative flow configurations such that solute dilution is maximized. To quantify dilution (i.e. a precondition that enables reactive mixing) we utilize the concept of the dilution index [1]. In this presentation, the periodic flow takes place in an aquifer with spatially variable hydraulic conductivity field which is modeled as a Stationary Spatial Random Function. We developed a novel first-order analytical solution of the dilution index under the hypothesis that the flow can be approximated as a sequence of steady state configurations with the mean velocity changing with time in intensity and direction. This is equivalent to assume that the characteristic time of the transient behavior is small compared to the period characterizing the change in time of the mean velocity. A few closed paths have been analyzed quantifying their effectiveness in enhancing dilution and thereby mixing

  1. Cost effectiveness of dilute chemical decontamination

    International Nuclear Information System (INIS)

    LeSurf, J.E.; Weyman, G.D.

    The basic principles of dilute chemical decontamination are described, as well as the method of application. Methods of computing savings in radiation dose and costs are presented, with results from actual experience and illustrative examples. It is concluded that dilute chemical decontamination is beneficial in many cases. It reduces radiation exposure of workers, saves money, and simplifies maintenance work

  2. The use of stable isotope dilution technique to determine the amount of breast milk consumed by infants

    International Nuclear Information System (INIS)

    Sajet, A. S.

    2011-01-01

    Exclusive breast feeding for six months to an infant, followed by the introduction of complementary food and continued with breast feeding is believed to be an optimal way of infants nutrition. There is a shortage in information about the amount of milk obtained from the infant's mother at least partially due to the difficulties associated with quantification of breast milk intake. The old technique, which depends on how the weight of the baby before and after breast feeding from mother, takes time and may be disturbing to the natural feeding pattern. It was possible to overcome these difficulties by using stable isotopes consumed by mother as D ose of deuterium oxide to mother i n particular dilution dose to mother and then move the dose from mother to baby through breast milk and this can calculate the total volume of breast milk consumed by the infant within 14 days since the dose oxide of deuterium consumed at first day. Dose of deuterium oxide to mother can also help to find out if there were any further quantity of water entering the child's body except breast milk, determine body composition for mother and infant, monitor the effects of programs strengthening food for pregnant mothers and lactating women in terms of quantity and quality of milk overnight, in addition to evaluating the effectiveness of programs to strengthen children's food. (author)

  3. A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients

    Czech Academy of Sciences Publication Activity Database

    Chan, C.; Smith, D.; Španěl, Patrik; McIntyre, Ch. W.; Davies, S. J.

    2008-01-01

    Roč. 23, č. 6 (2008), s. 2064-2070 ISSN 0931-0509 Institutional research plan: CEZ:AV0Z40400503 Keywords : flowing after-glow mass spectrometer (FA-MS) * body composition * deuterium dilution Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.568, year: 2008

  4. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam; Zhang, Ji; Fang, Tiegang; Roberts, William L.

    2014-01-01

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both

  5. Vitamin A metabolism, kinetic behavior and utilization: Rationale for the continued development and use of an isotope dilution technique for assessing vitamin A stores in human populations

    International Nuclear Information System (INIS)

    Green, M.H.

    1997-01-01

    The paper discusses the applicability of isotope dilution method in general and oral isotope dilution in particular to the assessment of vitamin A status in humans. It also highlights some aspects of vitamin A intake and metabolism as related to isotope dilution method. Areas of methodological research and development in vitamin A research are also proposed

  6. Neutron scattering study of dilute supercritical solutions

    International Nuclear Information System (INIS)

    Cochran, H.D.; Wignall, G.D.; Shah, V.M.; Londono, J.D.; Bienkowski, P.R.

    1994-01-01

    Dilute solutions in supercritical solvents exhibit interesting microstructures that are related to their dramatic macroscopic behavior. In typical attractive solutions, solutes are believed to be surrounded by clusters of solvent molecules, and solute molecules are believed to congregate in the vicinity of one another. Repulsive solutions, on the other hand, exhibit a local region of reduced solvent density around the solute with solute-solute congregation. Such microstructures influence solubility, partial molar volume, reaction kinetics, and many other properties. We have undertaken to observe these interesting microstructures directly by neutron scattering experiments on dilute noble gas systems including Ar. The three partial structure factors for such systems and the corresponding pair correlation functions can be determined by using the isotope substitution technique. The systems studied are uniquely suited for our objectives because of the large coherent neutron scattering length of the isotope 36 Ar and because of the accurate potential energy functions that are available for use in molecular simulations and theoretical calculations to be compared with the scattering results. We will describe our experiment, the unique apparatus we have built for it, and the neutron scattering results from our initial allocations of beam time. We will also describe planned scattering experiments to follow those with noble gases, including study of long-chain molecules in supercritical solvents. Such studies will involve hydrocarbon mixtures with and without deuteration to provide contrast

  7. The phase diagrams and the order parameters of the diluted superlattice with antiferromagnetic interface coupling

    International Nuclear Information System (INIS)

    Oubelkacem, A.; El Aouad, N.; Bentaleb, M.; Laaboudi, B.; Saber, M.

    2004-01-01

    Using the effective field theory with a probability distribution technique that accounts for the self-spin correlation functions, the magnetic properties of the diluted Ising superlattice consisting of two ferromagnetic materials A and B, with L a layers of diluted spins S a =((1)/(2)) and L b layers of diluted spins S b =1 with antiferromagnetic interface coupling are examined. For fixed values of the reduced exchange interactions and the concentration c of magnetic atoms, the phase diagrams, the two sublattice magnetizations and the total magnetization for the superlattice with the same spin S a =S b =((1)/(2)) and for S a =((1)/(2)), S b =1 are studied as a function of the temperature. We find a number of characteristic phenomena. In particular, the effect of the concentration c of magnetic atoms, the interlayer coupling and the layer thickness on both the compensation temperature and the magnetization profiles are clarified

  8. Nutritional assessment by isotope dilution analysis of body composition

    International Nuclear Information System (INIS)

    Szeluga, D.J.; Stuart, R.K.; Utermohlen, V.; Santos, G.W.

    1984-01-01

    The three components of body mass, body cell mass (BCM), extracellular fluid (ECF), and fat + extracellular solids (ECS: bone, tendon, etc) can be quantified using established isotope dilution techniques. With these techniques, total body water (TBW) and ECF are measured using 3H 2 O and 82 Bromine, respectively, as tracers. BCM is calculated from intracellular fluid (ICF) where ICF . TBW - ECF. Fat + ECS is estimated as: body weight - (BCM + ECF). TBW and ECF can be determined by either of two calculation methods, one requiring several timed plasma samples (extrapolation method) and one requiring a single plasma sample and a 4-h urine collection (urine-corrected method). The comparability of the two calculation methods was evaluated in 20 studies in 12 bone marrow transplant recipients. We found that for determination of TBW and ECF there was a very strong linear relationship (r2 greater than 0.98) between the calculation methods. Further comparisons (by t test, 2-sided) indicated that for the determination of ECF, the methods were not significantly (p greater than 0.90) different; however, TBW determined by the urine-corrected method was slightly (0.1 to 6%), but significantly (p less than 0.01) greater than that determined by the extrapolation method. Therefore, relative to the extrapolation method, the urine-corrected method ''over-estimates'' BCM and ''under-estimates'' fat + ECS since determination of these compartment sizes depends on measurement of TBW. We currently use serial isotope dilution studies to monitor the body composition changes of patients receiving therapeutic nutritional support

  9. Mechanisms of urine concentration and dilution (1961)

    International Nuclear Information System (INIS)

    Morel, F.; Guinnebault, M.

    1961-01-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [fr

  10. Sterility and Stability of Diluted Carprofen in a Multidose Vial in the Laboratory Animal Setting.

    Science.gov (United States)

    Simonek, Gregory D; Alarcio, Gwendolyne G; Brignolo, Laurie L

    2017-05-01

    Using compounded multidose vials (cMDV) is a common practice in the laboratory animal setting, where medications often are diluted to provide appropriate doses to rodents. However, bacterial contamination of MDV has been well established in both the human and veterinary medical literature. For this study, we created 14 cMDV by diluting carprofen into sterile water (dilution, 1:10) and stored 6 cMDV each at 5 and 24 °C. The stoppers of the cMDV were not cleaned with alcohol, and all were punctured twice daily for 28 d. The sterility of the diluted carprofen was evaluated by assessing bacterial growth on days 0, 7, 14, 21, and 28 and by testing for bacterial endotoxin on days 0 and 28. We used liquid chromatography-tandem mass spectrometry to assess the stability of 2 cMDV, with each cMDV being divided into the 2 storage-temperature subsets for days 0, 7, 14, 21, and 28. Neither bacterial contamination nor endotoxin was detected, and drug stability was stable over the 28 d. We suggest that with pragmatic techniques, such as secondary containment and consistent use of new needles, the contents of cMDV can remain sterile and stable for 28 d.

  11. ELISA technique standardisation for human toxocariasis diagnosis

    International Nuclear Information System (INIS)

    Espinoza, Y.; Suarez, R.; Huiza, A.

    2003-01-01

    To standardise ELISA technique for toxocara canis human infection diagnosis by using excreted-secreted antigen prepared in our country. T. canis eggs were collected by incubation with formalin (2%) at 28 o C in order to obtain third stage larvae that were freed and incubated in RPMI at 37 o C for 7 days; the medium was replaced by a similar one and stored at -20 o C. Antigen was concentrated and protein dosage was made. Sera from patients with toxocariasis and newborns were used as positive and negative controls by ELISA technique, dilutions 1/4 to 1/1024. Polystyrene plates were sensitised with antigen in several concentrations and conjugated peroxidase with horseradish IgG, anti human IgG and substrate OPD were used. Absorbance was read with spectrophotometer (Multiskan plus labsystems) at 492 nm. Cut off point was determined by negative sera absorbencies arithmetic mean plus 3 standard deviations. Antigen concentration was 50 ug/mL, sera dilution 1/128, conjugate dilution 1/1000 with optical density above 0,241. ELISA technique for serologic diagnosis of human infection by toxocara canis could be used in epidemiological studies in our country. Its efficacy will be determined in future studies

  12. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  13. Use of diluted urine for cultivation of Chlorella vulgaris.

    Science.gov (United States)

    Jaatinen, Sanna; Lakaniemi, Aino-Maija; Rintala, Jukka

    2016-01-01

    Our aim was to study the biomass growth of microalga Chlorella vulgaris using diluted human urine as a sole nutrient source. Batch cultivations (21 days) were conducted in five different urine dilutions (1:25-1:300), in 1:100-diluted urine as such and with added trace elements, and as a reference, in artificial growth medium. The highest biomass density was obtained in 1:100-diluted urine with and without additional trace elements (0.73 and 0.60 g L(-1), respectively). Similar biomass growth trends and densities were obtained with 1:25- and 1:300-diluted urine (0.52 vs. 0.48 gVSS L(-1)) indicating that urine at dilution 1:25 can be used to cultivate microalgal based biomass. Interestingly, even 1:300-diluted urine contained sufficiently nutrients and trace elements to support biomass growth. Biomass production was similar despite pH-variation from < 5 to 9 in different incubations indicating robustness of the biomass growth. Ammonium formation did not inhibit overall biomass growth. At the beginning of cultivation, the majority of the biomass consisted of living algal cells, while towards the end, their share decreased and the estimated share of bacteria and cell debris increased.

  14. Influence of extragent dilution upon light rare earths separation

    International Nuclear Information System (INIS)

    Korpusova, R.D.; Smirnova, N.N.

    1978-01-01

    The effect of diluting the extragent on separation of REE in the presence of 6 g-equiv. of LiNO 3 has been studied. For experiments use was made of TBP diluted with kerosene or butylbenzene (40,50,70 vol.%). The separation coefficients have been determined under conditions of saturation. The content of trace amounts of the components has been determined by the weight method; the content of macroimpurities - by the radiometric method. It has been established that the coefficient of Ce-La, Pr-La separation is not affected by the dilution of the extragent. The only exception is the Pr 142 -La pair; in the presence of trace amounts of better extracted element and two-fold dilution the separation coefficient increases almost by 150%. For the Pr-Ce pair the effect of dilution is better noticeable in that case when more extracted element is present in trace amounts. However, a comparison of the effect of dilution on separation coefficients of all REE pairs under study has shown that this effect is the strongest for the samarium-neodymium pair. The data obtained allow an assumption to be made that kerosene, as a diluent, affects the steric factor and coordination. Therefore, upon dilution the coefficient of the samarium-neodymium pair separation is affected most of all

  15. A new trajectory correction technique for linacs

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.; Ruth, R.D.

    1990-06-01

    In this paper, we describe a new trajectory correction technique for high energy linear accelerators. Current correction techniques force the beam trajectory to follow misalignments of the Beam Position Monitors. Since the particle bunch has a finite energy spread and particles with different energies are deflected differently, this causes ''chromatic'' dilution of the transverse beam emittance. The algorithm, which we describe in this paper, reduces the chromatic error by minimizing the energy dependence of the trajectory. To test the method we compare the effectiveness of our algorithm with a standard correction technique in simulations on a design linac for a Next Linear Collider. The simulations indicate that chromatic dilution would be debilitating in a future linear collider because of the very small beam sizes required to achieve the necessary luminosity. Thus, we feel that this technique will prove essential for future linear colliders. 3 refs., 6 figs., 2 tabs

  16. A probabilistic analysis of rapid boron dilution scenarios

    International Nuclear Information System (INIS)

    Kohut, P.; Diamond, D.J.

    1993-01-01

    A probabilistic and deterministic analysis of a rapid boron dilution scenario related to reactor restart was performed. The event is initiated by a loss of off-site power during the startup dilution process. The automatic restart of the charging pump in such cases may lead to the accumulation of a diluted slug of water in the lower plenum. The restart of the reactor coolant pumps may send the diluted slug through the core, adding sufficient reactivity to overcome the shutdown margin and cause a power excursion. The concern is that the power excursion is sufficient in certain circumstances to cause fuel damage. The estimated core damage frequency based on the scoping analysis is 1.0--3.0E-05/yr for the plants analyzed. These are relatively significant values when compared to desirable goals. The analysis contained assumptions related to plant specific design characteristics which may lead to non-conservative estimates. The most important conservative assumptions were that mixing of the injected diluted water is insignificant and that fuel damage occurs when the slug passes through the core

  17. Helium dilution refrigerator

    International Nuclear Information System (INIS)

    1973-01-01

    A new system of continuous heat exchange for a helium dilution refrigerator is proposed. The 3 He effluent tube is concurrent with the affluent mixed helium tube in a vertical downward direction. Heat exchange efficiency is enhanced by placing in series a number of elements with an enlarged surface area

  18. Relative volatility of dilute solutions of Rb-Cs system

    International Nuclear Information System (INIS)

    Gromov, P.B.; Izotov, V.P.; Nisel'son, L.A.

    1984-01-01

    Relative volatility of diluted solutions Rb-Cs in the temperature range 650-820 K and pressures 13-200 gPa has been studied. The system Rb-Cs in the range of diluted solutions obeys the Henry law. It is shown, that liquid-vapour equilibrium in diluted solutions of cesium in rubidium is characterized by negative deviation from perfection

  19. Regression dilution bias: tools for correction methods and sample size calculation.

    Science.gov (United States)

    Berglund, Lars

    2012-08-01

    Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.

  20. The bond diluted spin-1 Blume-Emery-Griffiths model in a transverse field

    International Nuclear Information System (INIS)

    Ez Zahraouy, H.

    1993-09-01

    The effect of Bond-dilution on the magnetic properties of a quantum transverse spin-1 Blume-Emery-Griffiths model is investigated within an expansion technique for cluster identities of a spin-1 localized spin system. The longitudinal and transverse magnetizations and quadrupolar moments are studied for several values of the bond concentration. A general formula, applicable to structures with arbitrary coordination number N, are given. (author). 41 refs, 6 figs

  1. Mechanisms of urine concentration and dilution (1961); Les mecanismes de concentration et de dilution de l'urine (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Morel, F; Guinnebault, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [French] Cette revue de question est consacree l'analyse d'un probleme de physiologie renale qui, au cours des dernieres annees, a subi un developpement et un renouveau remarquables. Sont successivement exposes: a) les donnees fournies par les mesures de clearance de l'eau libre et leur interpretation; b) les donnees fournies par la morphologie des nephrons et l'anatomie comparee du rein; c) les donnees concernant l'existence d'un gradient osmotique intrarenal; d) le principe de multiplication de concentration par contrecourant; e) la theorie actuelle de concentration de l'urine par contre-courant, et f) le controle physiologique des mecanismes de dilution et de concentration de l'urine. Les avantages de la theorie moderne et les obscurites qui subsistent sont enfin discutes. (auteurs)

  2. An overview the boron dilution issue in PWRs

    International Nuclear Information System (INIS)

    Hyvaerinen, J.

    1994-01-01

    The presentation is an overview of boron (boric acid) dilution in pressurized water reactors (PWRs). Boric acid has been widely used in PWRs as a dissolved poison, as one of the main reactivity controlling means, for a long time, from nearly but not quite from the beginning of the design, construction and operation of PWRs in the present-day sense. The specific safety issue, namely the risk of uncontrolled reactivity insertion due to inadvertent boron dilution, is discussed first, followed by a brief look on the history of boron usage in PWRs. A discussion of boron dilution phenomenology is presented next in general terms. Some particular concerns that boron dilution phenomena arouse in the minds of a regulator will also be presented before concluding with a brief look on the future of dissolved poisons. (11 refs.)

  3. Specific heat in diluted magnetic semiconductor quantum ring

    Science.gov (United States)

    Babanlı, A. M.; Ibragimov, B. G.

    2017-11-01

    In the present paper, we have calculated the specific heat and magnetization of a quantum ring of a diluted magnetic semiconductor (DMS) material in the presence of magnetic field. We take into account the effect of Rashba spin-orbital interaction, the exchange interaction and the Zeeman term on the specific heat. We have calculated the energy spectrum of the electrons in diluted magnetic semiconductor quantum ring. Moreover we have calculated the specific heat dependency on the magnetic field and Mn concentration at finite temperature of a diluted magnetic semiconductor quantum ring.

  4. The dilution effect on the extinction of wall diffusion flame

    Directory of Open Access Journals (Sweden)

    Ghiti Nadjib

    2014-12-01

    Full Text Available The dynamic process of the interaction between a turbulent jet diffusion methane flame and a lateral wall was experimentally studied. The evolution of the flame temperature field with the Nitrogen dilution of the methane jet flame was examined. The interaction between the diffusion flame and the lateral wall was investigated for different distance between the wall and the central axes of the jet flame. The dilution is found to play the central role in the flame extinction process. The flame response as the lateral wall approaches from infinity and the increasing of the dilution rate make the flame extinction more rapid than the flame without dilution, when the nitrogen dilution rate increase the flame temperature decrease.

  5. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Within the framework of the Safeguards Project of the Federal Republic of Germany at the Nuclear Research Center Karlsruhe an analytical intercomparison program was carried out in cooperation with 22 laboratories of 13 countries or international organizations. The main objective was the acquisition of basic data on the errors involved in the mass spectrometric isotope dilution analysis if it is applied to the determination of uranium and plutonium in diluted active feed solutions of reprocessing plants in routine operation. The results were evaluated by statistical methods mainly in regard to the calculation of the estimates of the variances for the different error components contributing to the total error of this analytical technique. Furthermore, the performance of two new methods for sample conditioning suggested by the International Atomic Energy Agency, Vienna, and the European Institute for Transuranium Elements (EURATOM), Karlsruhe, was successfully tested. The results of some investigations on the stability of diluted high active feed solutions and on comparison analysis by X-ray fluorescence spectrometry are also included. Data on the analytical efforts (manhours) invested in this study are reported as well as general experiences made in the organization and performance of an experiment on such an extended international level. (orig.) [de

  6. Effect of the dilution factor on {sup 18}FDG and Na{sup 18}F samples for bacterial endotoxin test using PTS (portable test system)

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z., E-mail: mbs@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    {sup 18}FDG and Na{sup 18}F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as {sup 18}F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of {sup 18}FDG and Na{sup 18}F for PTS analysis. Two different dilution factors for {sup 18}FDG and 1:10 for Na{sup 18}F were essayed: 1:10 and 1:100. {sup 18}FDG and Na{sup 18} solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for {sup 18}FDG and 1:10 for Na{sup 18}F. The recovery of the product positive control was 98-12% for {sup 18}FDG 1:100 and 104-120% for Na{sup 18}F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for {sup 18}FDG and Na{sup 18}F routine endotoxin test. (author)

  7. Sm isotope composition and Sm/Eu ratio determination in an irradiated 153Eu sample by ion exchange chromatography-quadrupole inductively coupled plasma mass spectrometry combined with double spike isotope dilution technique

    International Nuclear Information System (INIS)

    Bourgeois, M.; Isnard, H.; Gourgiotis, A.; Stadelmann, G.; Gautier, C.; Mialle, S.; Nonell, A.; Chartier, F.

    2011-01-01

    Within the framework of the research undertaken by the French Atomic Energy Commission on transmutation of long-lived radionuclides, targets of highly enriched actinides and fission products were irradiated in the fast neutron reactor Phenix. Precise and accurate measurements of the isotopic and elemental composition of the enriched elements are therefore required. In order to obtain the uncertainties of several per mil and to reduce handling time and exposure to analyst on radioactive material, the on-line coupling of ion exchange chromatography with quadrupole inductively coupled plasma mass spectrometry has been associated with the technique of the double spike isotope dilution. We present in this paper the results obtained on an irradiated sample of Europium oxide powder (enriched at 99.13% in 153 Eu). After irradiation of around 5 mg of Eu 2 O 3 powder the theoretical calculations predict the formation of several micrograms of gadolinium and samarium isotopes. In relation to the very high activity of the sample after irradiation and the very low quantity of Sm formed, the on-line ion exchange chromatography separation of Gd, Sm and Eu before Sm isotope ratio measurements has been developed for the quantification of the 152 Sm/ 153 Eu ratio. These on-line measurements were associated with the double spike isotope dilution technique after calibration of a 147 Sm/ 151 Eu spike solution. The external reproducibility of Sm isotopic ratios was determined to be around 0.5% (2 σ) resulting in a final uncertainty on the 152 Sm/ 153 Eu ratio of around 1% (2 σ). These on-line measurements present therefore a robust and high-throughput alternative to the thermal-ionisation mass spectrometry technique used so far in combination with off-line chromatographic separation, particularly in nuclear applications where characterisation of high activity sample solutions is required. (authors)

  8. Effects of dissolved species on radiolysis of diluted seawater

    International Nuclear Information System (INIS)

    Hata, Kuniki; Hanawa, Satoshi; Kasahara, Shigeki; Motooka, Takafumi; Tsukada, Takashi; Muroya, Yusa; Yamashita, Shinichi; Katsumura, Yosuke

    2014-01-01

    Fukushima Daiichi Nuclear Power Plants (NPPs) experienced seawater injection into the cores and fuel pools as an emergent measure after the accident. After the accident, retained water has been continuously desalinized, and subsequently the concentration of chloride ion (Cl"-) has been kept at a lower level these days. These ions in seawater are known to affect water radiolysis, which causes the production of radiolytic products, such as hydrogen peroxide (H_2O_2), molecular hydrogen (H_2) and molecular oxygen (O_2). However, the effects of dissolved ions relating seawater on the production of the stable radiolytic products are not well understood in the diluted seawater. To understand of the production behavior in diluted seawater under radiation, radiolysis calculations were carried out. Production of H_2 is effectively suppressed by diluting by up to vol10%. The concentrations of oxidants (H_2O_2 and O_2) are also suppressed by dilution of dissolved species. The effect of oxidants on corrosion of materials is thought to be low when the seawater was diluted by less than 1 vol% by water. It is also shown that deaeration is one of the effective measure to suppress the concentrations of oxidants at a lower level for any dilution conditions. (author)

  9. Near-wall molecular ordering of dilute ionic liquids

    NARCIS (Netherlands)

    Jitvisate, Monchai; Seddon, James Richard Thorley

    2017-01-01

    The interfacial behavior of ionic liquids promises tunable lubrication as well as playing an integral role in ion diffusion for electron transfer. Diluting the ionic liquids optimizes bulk parameters, such as electric conductivity, and one would expect dilution to disrupt the near-wall molecular

  10. On the Wigner law in dilute random matrices

    Science.gov (United States)

    Khorunzhy, A.; Rodgers, G. J.

    1998-12-01

    We consider ensembles of N × N symmetric matrices whose entries are weakly dependent random variables. We show that random dilution can change the limiting eigenvalue distribution of such matrices. We prove that under general and natural conditions the normalised eigenvalue counting function coincides with the semicircle (Wigner) distribution in the limit N → ∞. This can be explained by the observation that dilution (or more generally, random modulation) eliminates the weak dependence (or correlations) between random matrix entries. It also supports our earlier conjecture that the Wigner distribution is stable to random dilution and modulation.

  11. Asymptotic Distribution of Eigenvalues of Weakly Dilute Wishart Matrices

    Energy Technology Data Exchange (ETDEWEB)

    Khorunzhy, A. [Institute for Low Temperature Physics (Ukraine)], E-mail: khorunjy@ilt.kharkov.ua; Rodgers, G. J. [Brunel University, Uxbridge, Department of Mathematics and Statistics (United Kingdom)], E-mail: g.j.rodgers@brunel.ac.uk

    2000-03-15

    We study the eigenvalue distribution of large random matrices that are randomly diluted. We consider two random matrix ensembles that in the pure (nondilute) case have a limiting eigenvalue distribution with a singular component at the origin. These include the Wishart random matrix ensemble and Gaussian random matrices with correlated entries. Our results show that the singularity in the eigenvalue distribution is rather unstable under dilution and that even weak dilution destroys it.

  12. Modeling syngas-fired gas turbine engines with two dilutants

    Science.gov (United States)

    Hawk, Mitchell E.

    2011-12-01

    Prior gas turbine engine modeling work at the University of Wyoming studied cycle performance and turbine design with air and CO2-diluted GTE cycles fired with methane and syngas fuels. Two of the cycles examined were unconventional and innovative. The work presented herein reexamines prior results and expands the modeling by including the impacts of turbine cooling and CO2 sequestration on GTE cycle performance. The simple, conventional regeneration and two alternative regeneration cycle configurations were examined. In contrast to air dilution, CO2 -diluted cycle efficiencies increased by approximately 1.0 percentage point for the three regeneration configurations examined, while the efficiency of the CO2-diluted simple cycle decreased by approximately 5.0 percentage points. For CO2-diluted cycles with a closed-exhaust recycling path, an optimum CO2-recycle pressure was determined for each configuration that was significantly lower than atmospheric pressure. Un-cooled alternative regeneration configurations with CO2 recycling achieved efficiencies near 50%, which was approximately 3.0 percentage points higher than the conventional regeneration cycle and simple cycle configurations that utilized CO2 recycling. Accounting for cooling of the first two turbine stages resulted in a 2--3 percentage point reduction in un-cooled efficiency, with air dilution corresponding to the upper extreme. Additionally, when the work required to sequester CO2 was accounted for, cooled cycle efficiency decreased by 4--6 percentage points, and was more negatively impacted when syngas fuels were used. Finally, turbine design models showed that turbine blades are shorter with CO2 dilution, resulting in fewer design restrictions.

  13. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960)

    International Nuclear Information System (INIS)

    Bovard, P.; Candillon, C.

    1960-01-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [fr

  14. Stable isotope dilution analysis by thermal ionization mass spectrometry. Pt. 2

    International Nuclear Information System (INIS)

    Broekman, A.; Raaphorst, J.G. van

    1984-01-01

    The combination of stable isotope dilution analysis (SIDA) and thermal ionization mass spectrometry (TIMS) is in use for lead and uranium determination at milligram per kilogram levels for over 20 years. However, several other elements can also be determined accurately by SIDA/TIMS. In this study the determinations of cadmium and copper are described. Details of the digestion, electrochemical and ion-exchange separations and the loading of the elements on a filament are given. The advantages of the SIDA/TIMS technique are shown and illustrated with results for several certified reference materials. (orig.) [de

  15. Time-resolved optically-detected magnetic resonance of II-VI diluted-magnetic-semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V.Yu.; Karczewski, G. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Godlewski, M. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Dept. Mathem. and Natural Sci. College of Sci., Card. S. Wyszynski Univ., Warsaw (Poland); Yakovlev, D.R. [Experimental Physics 2, University of Dortmund, 44221 Dortmund (Germany); A. F. Ioffe Physico-Technical Institute, 194017 St. Petersburg (Russian Federation); Ryabchenko, S.M. [Institute of Physics NAS Ukraine, 03028 Kiev (Ukraine); Waag, A. [Institute of Semiconductor Technology, Braunschweig Technical University, 38106 Braunschweig (Germany)

    2007-01-15

    Time-resolved optically-detected magnetic resonance (ODMR) technique was used to study spin dynamics of Mn{sup 2+} ions in (Zn,Mn)Se- and (Cd,Mn)Te-based diluted magnetic semiconductor quantum wells. Times of spin-lattice relaxation have been measured directly from a dynamical shift of exciton luminescence lines after a pulsed impact of 60 GHz microwave radiation. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Theoretical investigation of the heavily-doped semiconductor aspect of ultra-dilute GaAsN

    Science.gov (United States)

    Sukpitak, Jessada; Sa-yakanit, Virulh

    2015-12-01

    The model of GaAs1- y N y ( y = 0.001) as a heavily-doped semiconductor in the ultra-dilute region is attentively examined. The model enables GaAsN to be viewed as a disordered assembly of three-dimensional quantum dots (potential wells) caused by random potential fluctuations from nitrogen pairs in the system. Consequently, Feynman's path-integration technique is applied in order to quantify the density of states (DOS) in the vicinity of the conduction band edge. The obtained DOS tail, even though overestimated, still clearly shows a much shorter tail than that the experimental result does. This shows that the heavily-doped semiconductor viewpoint is not proper for GaAsN, not even in the ultra-dilute region. Furthermore, this also suggests that the impurity wave function overlap is not a basic mechanism of band gap reduction.

  17. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  18. Application of radioisotope techniques in analysis of environmental pollutants

    International Nuclear Information System (INIS)

    Kyrs, M.; Moravec, A.

    1984-01-01

    A survey is tabulated of the use of radioisotope techniques, giving the detected pollutant and the sensitivity and accuracy of the method. The most frequently used principle is the substoichiometric variant of isotope dilution which may be divided into the method of isotope dilution and the radio-reagent method. Both methods are described and examples are given of the determination of pollutants. (J.P.)

  19. Mechanisms of urine concentration and dilution (1961); Les mecanismes de concentration et de dilution de l'urine (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Morel, F.; Guinnebault, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [French] Cette revue de question est consacree l'analyse d'un probleme de physiologie renale qui, au cours des dernieres annees, a subi un developpement et un renouveau remarquables. Sont successivement exposes: a) les donnees fournies par les mesures de clearance de l'eau libre et leur interpretation; b) les donnees fournies par la morphologie des nephrons et l'anatomie comparee du rein; c) les donnees concernant l'existence d'un gradient osmotique intrarenal; d) le principe de multiplication de concentration par contrecourant; e) la theorie actuelle de concentration de l'urine par contre-courant, et f) le controle physiologique des mecanismes de dilution et de concentration de l'urine. Les avantages de la theorie moderne et les obscurites qui subsistent sont enfin discutes. (auteurs)

  20. Sugar yields from dilute oxalic acid pretreatment of maple wood compared to those with other dilute acids and hot water.

    Science.gov (United States)

    Zhang, Taiying; Kumar, Rajeev; Wyman, Charles E

    2013-01-30

    Dilute oxalic acid pretreatment was applied to maple wood to improve compatibility with downstream operations, and its performance in pretreatment and subsequent enzymatic hydrolysis was compared to results for hydrothermal and dilute hydrochloric and sulfuric acid pretreatments. The highest total xylose yield of ∼84% of the theoretical maximum was for both 0.5% oxalic and sulfuric acid pretreatment at 160 °C, compared to ∼81% yield for hydrothermal pretreatment at 200 °C and for 0.5% hydrochloric acid pretreatment at 140 °C. The xylooligomer fraction from dilute oxalic acid pretreatment was only 6.3% of the total xylose in solution, similar to results with dilute hydrochloric and sulfuric acids but much lower than the ∼70% value for hydrothermal pretreatment. Combining any of the four pretreatments with enzymatic hydrolysis with 60 FPU cellulase/g of glucan plus xylan in the pretreated maple wood resulted in virtually the same total glucose plus xylose yields of ∼85% of the maximum possible. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Charged particle detectors based on high quality amorphous silicon deposited with hydrogen or helium dilution of silane

    International Nuclear Information System (INIS)

    Hong, Wan-Shick; Drewery, J.S.; Jing, Tao; Lee, Hyoung-Koo; Kaplan, S.N.; Perez-Mendez, V.; Mireshghi, Ali; Kitsuno, Yu

    1994-11-01

    Electrical transport properties of the authors PECVD a-Si:H material has been improved by using hydrogen and/or helium dilution of silane and lower substrate temperature for deposition. For hydrogen-diluted material they have measured electron and hole mobilities ∼ 4 times larger, and μτ values 2-3 times higher than for their standard a-Si:H. The density of ionized dangling bonds (N D *) also showed a factor of 5-10 improvement. Due to its higher conductivity, the improved a- Si:H material is more suitable than conventional a-Si:H for TFT applications. However, it is difficult to make thick layers by H-dilution because of high internal stress. On the other hand, thick detectors can be made at a faster rate and lower stress by low temperature deposition with He-dilution and subsequent annealing. The internal stress, which causes substrate bending and delamination, was reduced by a factor of 4 to ∼90 MPa, while the electronic quality was kept as good as that of the standard material. By this technique 35 μm-thick n-i-p diodes were made without significant substrate bending, and the electronic properties, such as electron mobility and ionized dangling bond density, were suitable for detecting minimum ionizing particles

  2. Charged particle detectors based on high quality amorphous silicon deposited with hydrogen or helium dilution of silane

    International Nuclear Information System (INIS)

    Hong, W.S.; Drewery, J.S.; Jing, T.; Lee, H.; Kaplan, S.N.; Perez-Mendez, V.; Kitsuno, Y.

    1995-01-01

    Electrical transport properties of the PECVD a-Si:H material has been improved by using hydrogen and/or helium dilution of silane and lower substrate temperature for deposition. For hydrogen-diluted material the authors measured electron and hole mobilities ∼4 times larger, and microτ values 2--3 times higher than for the standard a-Si:H. The density of ionized dangling bonds (N D *) also showed a factor of 5--10 improvement. Due to its higher conductivity, the improved a-Si:H material is more suitable than conventional a-Si:H for TFT applications. However, it is difficult to make thick layers by H-dilution because of high internal stress. On the other hand, thick detectors can be made at a faster rate and lower stress by low temperature deposition with He-dilution and subsequent annealing. The internal stress, which causes substrate bending and delamination, was reduced by a factor of 4 to ∼90 MPa, while the electronic quality was kept as good as that of the standard material. By this technique 35 microm-thick n-i-p diodes were made without significant substrate bending, and the electronic properties, such as electron mobility and ionized dangling bond density, were suitable for detecting minimum ionizing particles

  3. Assessment of body fat in the pony: part II. Validation of the deuterium oxide dilution technique for the measurement of body fat.

    Science.gov (United States)

    Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc

    2011-09-01

    Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.

  4. Uranium determination in sea water using the isotopic dilution technique and HR-ICPMS

    International Nuclear Information System (INIS)

    Pereira, Marcio Henrique da Costa; Sarkis, Jorge Eduardo de Souza; Hortellani, Marcos Antonio; Nascimento, Marcos R.L.

    2009-01-01

    In this work, the uranium total and the isotopic composition in seawater were calculated using the isotopic dilution applied to the mass spectrometry. The used tracer was a 233 U solution . Near 99 % of the present salts in the matrix were separated by evaporation up to the saturation point. The uranium present in aqueous phase was separated from the matrix through the ion exchange chromatography using the strong Dowex 1 x 8 200-400 mesh anionic resin in chloridric medium 12 M. The analyses were performed in a high resolution mass spectrometer with plasma inductively coupled source. The method validation was done using the seawater standard CASS-4 (Near shore Seawater Reference Material for Trace metals) produced by the NRC C. The procedure allowed to obtain the fractions exempt of salts, having as consequence a greater stability in the analytical signal, and a rise in the instrumental revenue for a great number of samples. The uranium found in the samples was present in levels considered naturals and were obtained with a precision near 2 %

  5. Gas chromatography/ion trap mass spectrometry applied for the analysis of triazine herbicides in environmental waters by an isotope dilution technique

    International Nuclear Information System (INIS)

    Cai Zongwei; Wang Dongli; Ma, W.T.

    2004-01-01

    A gas chromatography/ion trap mass spectrometry method was developed for the analysis of simazine, atrazine, cyanazine, as well as the degradation products of atrazine, such as deethylatrazine and deisopropylatrazine in environmental water samples. Isotope dilution technique was applied for the quantitative analysis of atrazine in water at low ng/l levels. One liter of water sample spiked with stable isotope internal standard atrazine-d 5 was extracted with a C 18 solid-phase extraction cartridge. The analysis was performed on an ion trap mass spectrometer operated in MS/MS method. The extraction recoveries were in the range of 83-94% for the triazine herbicides in water at the concentrations of 24, 200, and 1000 ng/l, while poor recoveries were obtained for the degradation products of atrazine. The relative standard deviation (R.S.D.) were within the range of 3.2-16.1%. The detection limits of the method were between 0.75 and 12 ng/l when 1 l of water was analyzed. The method was successfully applied to analyze environmental water samples collected from a reservoir and a river in Hong Kong for atrazine detected at concentrations between 3.4 and 26 ng/l

  6. Dilution Ratios for HB Line Phase I Eductor System

    International Nuclear Information System (INIS)

    Steimke, J.L.

    2002-01-01

    HB Line Phase I product transfer includes an eductor which transfers liquid from Product Hold Tank (PHT) RT-33 or RT-34 to Tank 11.1. The eductor also dilutes the liquid from the PHT with eductant. Dilution must be reliably controlled because of criticality concerns with H Canyon Tanks. The eductor system, which contains a 1 inch Model 264 Schutte and Koerting eductor, was previously modeled [1] in 1998 and dilution ratios were calculated for different flow restrictors, eductant pressures and densities for the eductant and the contents of the PHT. The previous calculation was performed using spreadsheet software no longer supported at SRS. For the previous work dilution ratio was defined as the volume of eductant consumed divided by volume of PHT contents transferred. Since 1998 HB Line Engineering has changed the definition of dilution ratio to the total volume of liquid, eductant consumed plus the volume of PHT liquid transferred, divided by the volume of PHT liquid transferred. The 1998 base case calculation was for a restrictor diameter of 0.334 inches, an eductant supply pressure of 15 psig, full PHT, an eductant specific gravity of 1.385 and a PHT density of 1.015. The base case dilution ratio calculated in 1998 using the current definition was 3.52. After accounting for uncertainty the minimum dilution ratio decreased to 3.23. In 2001 HB Line Engineering requested that the calculation be repeated for a manganous nitrate solution eductant and also a process water eductant. The other conditions were the same as for the 1998 calculation. The objective of this report is to document the calculations and the results

  7. Crystallization of calcium oxalate in minimally diluted urine

    Science.gov (United States)

    Bretherton, T.; Rodgers, A.

    1998-09-01

    Crystallization of calcium oxalate was studied in minimally diluted (92%) urine using a mixed suspension mixed product crystallizer in series with a Malvern particle sizer. The crystallization was initiated by constant flow of aqueous sodium oxalate and urine into the reaction vessel via two independent feed lines. Because the Malvern cell was in series with the reaction vessel, noninvasive measurement of particle sizes could be effected. In addition, aliquots of the mixed suspension were withdrawn and transferred to a Coulter counter for crystal counting and sizing. Steady-state particle size distributions were used to determine nucleation and growth kinetics while scanning electron microscopy was used to examine deposited crystals. Two sets of experiments were performed. In the first, the effect of the concentration of the exogenous sodium oxalate was investigated while in the second, the effect of temperature was studied. Calcium oxalate nucleation and growth rates were found to be dependent on supersaturation levels inside the crystallizer. However, while growth rate increased with increasing temperature, nucleation rates decreased. The favored phases were the trihydrate at 18°C, the dihydrate at 38° and the monohydrate at 58°C. The results of both experiments are in agreement with those obtained in other studies that have been conducted in synthetic and in maximally diluted urine and which have employed invasive crystal counting and sizing techniques. As such, the present study lends confidence to the models of urinary calcium oxalate crystallization processes which currently prevail in the literature.

  8. Behaviour of humic-bentonite aggregates in diluted suspensions ...

    African Journals Online (AJOL)

    Formation and disaggregation of micron-size aggregates in a diluted suspension made up of HSs and bentonite (B) were studied by tracing distribution of aggregate sizes and their counts in freshly prepared and aged suspensions, and at high (10 000) and low (1.0) [HS]/[B] ratios. Diluted HSB suspensions are unstable ...

  9. Hemodiafiltración en línea pre-dilucional, frente a post-dilucional: estudio comparativo de eficacia dialítica y tolerancia hemodinámica Pre-dilution versus post-dilution on-line haemodiafiltration: a comparative study of dialytic efficacy and haemodynamic tolerance

    Directory of Open Access Journals (Sweden)

    Raquel Menezo Viadero

    2012-06-01

    -dilucional en relación a los parámetros estudiados siempre que no se tenga en cuenta la problemática de los accesos vasculares. Con dicha técnica logramos mejores resultados de KT precisando la mitad de volumen de sustitución, con el consiguiente ahorro de agua ultrapura. La hemodiafiltración pre-dilucional puede ser una alternativa para aquellos pacientes que no se consiga un flujo arterial alto.On-line haemodiafiltration is a dialysis technique which combines the advantages of high-flow haemodialysis (diffusive transport and haemofiltration (convective transport. This technique allows different alternatives depending on how the reinfusion liquid is added: pre-dilution (before the dialyser and post-dilution (after the dialyser, each of them having advantages and disadvantages. The object of this study was to compare different dialytic and haemodynamic parameters in the pre- and post-dilution haemodiafiltration modes. A transversal prospective study was conducted of a population in dialysis already being treated with on-line haemodiafiltration, using each of the modes (pre- and post-dilution with them for 4 weeks. The following values were recorded: systolic and diastolic arterial pressure and cardiac frequency pre- and post-session, blood flow, venous pressure, volume of blood dialysed and replacement volume. Dialysis dosage was measured by means of ionic dialysance. 26 patients were studied: 30% women and 70% men, with an average age of 61±13 years. The average time under renal replacement treatment was 117±124.45 months, and the average time in haemodialysis was 50±54.38 months. The haemodynamic parameters showed no significant differences between the two modes studied (pre- and post-dilution. A statistically significant higher value for KT was obtained for the post-dilution haemodiafiltration technique, requiring half the replacement volume of the pre-dilution mode. Conclusions: The on-line haemodiafiltration technique is tolerated well in both infusion modes. With

  10. Diluted magnetic semiconductor nanowires exhibiting magnetoresistance

    Science.gov (United States)

    Yang, Peidong [El Cerrito, CA; Choi, Heonjin [Seoul, KR; Lee, Sangkwon [Daejeon, KR; He, Rongrui [Albany, CA; Zhang, Yanfeng [El Cerrito, CA; Kuykendal, Tevye [Berkeley, CA; Pauzauskie, Peter [Berkeley, CA

    2011-08-23

    A method for is disclosed for fabricating diluted magnetic semiconductor (DMS) nanowires by providing a catalyst-coated substrate and subjecting at least a portion of the substrate to a semiconductor, and dopant via chloride-based vapor transport to synthesize the nanowires. Using this novel chloride-based chemical vapor transport process, single crystalline diluted magnetic semiconductor nanowires Ga.sub.1-xMn.sub.xN (x=0.07) were synthesized. The nanowires, which have diameters of .about.10 nm to 100 nm and lengths of up to tens of micrometers, show ferromagnetism with Curie temperature above room temperature, and magnetoresistance up to 250 Kelvin.

  11. Mobile Melt-Dilute Treatment for Russian Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Peacock, H.

    2002-01-01

    Treatment of spent Russian fuel using a Melt-Dilute (MD) process is proposed to consolidate fuel assemblies into a form that is proliferation resistant and provides critically safety under storage and disposal configurations. Russian fuel elements contain a variety of fuel meat and cladding materials. The Melt-Dilute treatment process was initially developed for aluminum-based fuels so additional development is needed for several cladding and fuel meat combinations in the Russian fuel inventory (e.g. zirconium-clad, uranium-zirconium alloy fuel). A Mobile Melt-Dilute facility (MMD) is being proposed for treatment of spent fuels at reactor site storage locations in Russia; thereby, avoiding the costs of building separate treatment facilities at each site and avoiding shipment of enriched fuel assemblies over the road. The MMD facility concept is based on laboratory tests conducted at the Savannah River Technology Center (SRTC), and modular pilot-scale facilities constructed at the Savannah River Site for treatment of US spent fuel. SRTC laboratory tests have shown the feasibility of operating a Melt-Dilute treatment process with either a closed system or a filtered off-gas system. The proposed Mobile Melt-Dilute process is presented in this paper

  12. Plutonium determination by isotope dilution

    International Nuclear Information System (INIS)

    Lucas, M.

    1980-01-01

    The principle is to add to a known amount of the analysed solution a known amount of a spike solution consisting of plutonium 242. The isotopic composition of the resulting mixture is then determined by surface ionization mass spectrometry, and the plutonium concentration in the solution is deduced, from this measurement. For irradiated fuels neutronic studies or for fissile materials balance measurements, requiring the knowledge of the ratio U/Pu or of concentration both uranium and plutonium, it is better to use the double spike isotope dilution method, with a spike solution of known 233 U- 242 Pu ratio. Using this method, the ratio of uranium to plutonium concentration in the irradiated fuel solution can be determined without any accurate measurement of the mixed amounts of sample and spike solutions. For fissile material balance measurements, the uranium concentration is determined by using single isotope dilution, and the plutonium concentration is deduced from the ratio Pu/U and U concentration. The main advantages of isotope dilution are its selectivity, accuracy and very high sensitivity. The recent improvements made to surface ionization mass spectrometers have considerably increased the precision of the measurements; a relative precision of about 0.2% to 0.3% is obtained currently, but it could be reduced to 0.1%, in the future, with a careful control of the experimental procedures. The detection limite is around 0.1 ppb [fr

  13. Magnetic ordering in dilute YTb and YEr alloys

    International Nuclear Information System (INIS)

    Rainford, B.D.; Kilcoyne, S.H.; Mohammed, K.A.; Lanchester, P.C.; Stanley, H.B.; Caudron, R.

    1988-01-01

    Dilute YEr alloys (Er concentration between 3% and 10%) show the existence of sinusoidally modulated antiferromagnetism down to the lowest impurity concentrations studied. Extrapolation of the Neel temperatures for both YEr and YTb suggests a critical concentration is ≅ 0.8% Tb, Er. Ordering in such dilute alloys may result from exchange enhancement in the yttrium host

  14. Magnetic ordering in dilute YTb and YEr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Rainford, B.D.; Kilcoyne, S.H.; Mohammed, K.A.; Lanchester, P.C.; Stanley, H.B.; Caudron, R.

    1988-12-01

    Dilute YEr alloys (Er concentration between 3% and 10%) show the existence of sinusoidally modulated antiferromagnetism down to the lowest impurity concentrations studied. Extrapolation of the Neel temperatures for both YEr and YTb suggests a critical concentration is /approx equal/ 0.8% Tb, Er. Ordering in such dilute alloys may result from exchange enhancement in the yttrium host.

  15. Magneto-electrochemical recovery of diluted metals using three-dimensionally structured electrodes

    Science.gov (United States)

    Fernández, Dámaris; Romeral, Luis; Lyons, Michael E. G.

    2015-04-01

    In a typical metal recovery process, where highly purified metals are obtained from a concentrated electrolyte, usually the cathodic electrodes are planar and can be described mainly as bi-dimensional. This leads to a low space-time yield and low normalized space velocity with an impact on production rates. New requirements of low-energy consumption yet intensive production factories impose the need to adequate electrodes in order to comply. Furthermore, a reduction in the number of steps required to achieve a product would be ideal. This suggests that direct electro-precipitation of metals contained in diluted electrolytes would be in principle a desirable technique to implement. However, the less concentrated the solution, the higher the IR drop becomes, making the process more energy-consuming and current efficiency strongly decays. Good potential alternatives arise from three-dimensionally designed electrodes in the form of mesh, porous or fluidized beds, for instance, and several examples are well known in literature. Nevertheless, current efficiency can still be a problem in the more diluted electrolytes. Furthermore, the anodic electrode, where the counter reaction takes place, plays also an important role in determining the current efficiency of the overall process. In this case, the liquid-to-gas phase transition implies that the electrodes get a strong gas shield that increases the IR drop. Whereas shifting from bi-dimensional to three-dimensional electrodes could provide an alternative for achieving better performances, it is still far from the expected targets. Therefore alternative or complementary techniques to improve efficiency are required. It is well known that magnetic fields coupled with electric fields enhance mass transport via de Lorentz and other forces. In this work, the applications and properties of three-dimensional arrays subject to magnetic field interactions are examined and compared with the traditional bi-dimensional electrodes

  16. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  17. Calculations for BDAS Setpoint with Non-conservative Boron Dilution Analysis

    International Nuclear Information System (INIS)

    Lee, Hwan Soo; Shin, Ho Cheol; Kim, Yong Bae

    2014-01-01

    BDAS (Boron Dilution Alarm System) utilizes the ex-core detector instrumentation signals to detect a possible inadvertent boron dilution event during operation mode 3, 4, 5, 6. For boron dilution analysis, discrepancies in the active coolant volume and the assumed linearity of the ex-core instrumentation response were identified for CE type PWR and they were reported by NASL-04-02 These discrepancies have potential to impact to determine BDAS setpoint in a non-conservative manner Therefore, in this study, the calculation of BDAS setpoint with those discrepancies condition about OPR1000 was performed and analyzed for checking the safety of BDAS. The new BDAS setpoint is calculated with conservative condition which recommended from Westinghouse Electric Company. The setpoint of BDAS using non-linear ICRR curve decrease to about 5% compared to the setpoint of that using linear ICRR curve. And this effect of the non-linearity is to slightly delay the boron dilution alarm during the inadvertence boron dilution at mode 3, 4, and 5

  18. Single-borehole techniques

    International Nuclear Information System (INIS)

    Klotz, D.; Moser, H.; Trimborn, P.

    1978-01-01

    Proceeding on the theoretical considerations and on the experience and practice derived from laboratory and field testing, a system consisting of tracer injection units, detector units, measuring probe units and packers is presented, from which the different borehole probes required can be combined. A couple of examples of recent applications shows the position of the Single-Borehole Techniques with respect to the traditional methods used for the measurement of the ground-water flow. A confrontation of the permeabilities of different aquifers consents, both on the basis of the Single-Borehole Techniques as by pumping experiments, the determination of the reliability of the Point-Dilution-Method. The Point-Dilution-Method is giving information about the vertical and horizontal distribution of the permeabilities in an aquifer. By measuring the vertical current in two karst wells, the tributary horizons of a well have been determined, which gave valuable information for the subsequent well construction. Local leakages could be detected by measuring the vertical flow rate through observation wells arranged along a grout curtain erected on both sides of the retaining barrage of the Keban dam. (orig.) [de

  19. Accuracy of the tritium water dilution method for determining water flux in reindeer (Rangifer tarandus)

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, R D; White, R G; Luick, J R

    1976-06-01

    The accuracy of the tritium water dilution method in estimating water flux was evaluated in reindeer under various conditions of temperature and diet. Two non-pregnant female reindeer were restrained in metabolism stalls, within controlled-environment chambers, at temperatures of +10, -5, and -20/sup 0/C; varying amounts of a commercial pelleted ration (crude protein, 13 percent) or mixed lichens (crude protein, 3 percent) were offered, and water was provided ad libitum either as snow or in liquid form. Total body water volume and water turnover were estimated using tritiated water, and the daily outputs of feces and urine were measured for each of 12 different combinations of diet and temperature. Statistical analysis of the data showed that the tritium water dilution technique gives accurate determinations of total body water flux over a wide range of environmental and nutritional conditions.

  20. Paradigms in isotope dilution mass spectrometry for elemental speciation analysis

    International Nuclear Information System (INIS)

    Meija, Juris; Mester, Zoltan

    2008-01-01

    Isotope dilution mass spectrometry currently stands out as the method providing results with unchallenged precision and accuracy in elemental speciation. However, recent history of isotope dilution mass spectrometry has shown that the extent to which this primary ratio measurement method can deliver accurate results is still subject of active research. In this review, we will summarize the fundamental prerequisites behind isotope dilution mass spectrometry and discuss their practical limits of validity and effects on the accuracy of the obtained results. This review is not to be viewed as a critique of isotope dilution; rather its purpose is to highlight the lesser studied aspects that will ensure and elevate current supremacy of the results obtained from this method

  1. Activity coefficients at infinite dilution of hydrocarbons in glycols: Experimental data and thermodynamic modeling with the GCA-EoS

    International Nuclear Information System (INIS)

    González Prieto, Mariana; Williams-Wynn, Mark D.; Bahadur, Indra; Sánchez, Francisco A.; Mohammadi, Amir H.

    2017-01-01

    Highlights: • Experimental infinite dilution activity coefficients of hydrocarbons in glycols. • Inverse gas-liquid chromatography technique. • Solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. • Highly non-ideal systems are modeled with the GCA-EoS. - Abstract: The infinite dilution activity coefficients for 12 non-polar hydrocarbon solutes in the solvents, monoethylene and diethylene glycol, were measured using the gas-liquid chromatography technique. Pre-saturation of the carrier gas was required to avoid solvent loss from the chromatographic column during the measurements that were carried out at T = (303.15, 313.15 and 323.15) K for monoethylene glycol and at T = (304.15, 313.15 and 323.15) K for diethylene glycol. The solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. The new data are compared with the highly scattered data that is available in the open literature. Finally, these highly non-ideal systems are modeled with the GCA-EoS.

  2. Forms of vitamin B12 in radioisotope dilution assays

    International Nuclear Information System (INIS)

    Begley, J.A.; Hall, C.A.

    1981-01-01

    Since the presence of analogues of vitamin B 12 (B 12 , cobalamin, Cbl) has been postulated as the basis for the high values obtained by some radioisotope dilution assays (RIDA) of serum Cbl, serum was examined for analogues. None could be demonstrated in the extracts of serum prepared for RIDA as sought by both direct and indirect techniques. The natural forms of serum Cbl were converted to cyanocobalamin (CN Cbl) by this process of extraction which included cyanide (CN). The correctly performed RIDA for Cbl based on R binder gave higher values than a RIDA based on intrinsic factor or than by bioassay. By exclusion, the difference appeared to be due to unidentified factors rather than the presence of analogues. (author)

  3. Quantifying the dilution effect for models in ecological epidemiology.

    Science.gov (United States)

    Roberts, M G; Heesterbeek, J A P

    2018-03-01

    The dilution effect , where an increase in biodiversity results in a reduction in the prevalence of an infectious disease, has been the subject of speculation and controversy. Conversely, an amplification effect occurs when increased biodiversity is related to an increase in prevalence. We explore the conditions under which these effects arise, using multi species compartmental models that integrate ecological and epidemiological interactions. We introduce three potential metrics for quantifying dilution and amplification, one based on infection prevalence in a focal host species, one based on the size of the infected subpopulation of that species and one based on the basic reproduction number. We introduce our approach in the simplest epidemiological setting with two species, and show that the existence and strength of a dilution effect is influenced strongly by the choices made to describe the system and the metric used to gauge the effect. We show that our method can be generalized to any number of species and to more complicated ecological and epidemiological dynamics. Our method allows a rigorous analysis of ecological systems where dilution effects have been postulated, and contributes to future progress in understanding the phenomenon of dilution in the context of infectious disease dynamics and infection risk. © 2018 The Author(s).

  4. Single well techniques

    International Nuclear Information System (INIS)

    Drost, W.

    1983-01-01

    The single well technique method includes measurement of parameters of groundwater flow in saturated rock. For determination of filtration velocity the dilution of radioactive tracer is measured, for direction logging the collimeter is rotated in the probe linked with the compass. The limiting factor for measurement of high filtration velocities is the occurrence of turbulent flow. The single well technique is used in civil engineering projects, water works and subsurface drainage of liquid waste from disposal sites. The radioactive tracer method for logging the vertical fluid movement in bore-holes is broadly used in groundwater survey and exploitation. (author)

  5. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  6. performance of sorghum grown on a salt affected soil manured with dhaincha plant residues using a 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Al-Ain, F.; Razok, A.; Al-Shamma, M.

    2008-01-01

    A field experiment was conducted on a salt-affected soil to determine the effect of application of three types of Dhaincha (Sesbania aculeata pers.) residues (R, roots; L, shoots; L+R, shoots plus roots) of on the performance of sorghum (Sorghum bicolor L.) using the indirect 15 N isotopic dilution technique. Results indicated that Sesbania residues (L and L+R), used as green manures significantly increased grain yield, dry matter production, N uptake, and water use efficiency of sorghum. Percentages of N derived from residues (%Ndfr) in sorghum ranged from 6.4 to 28%. The N recoveries in sorghum were 52, 19. and 19.7% of the total amount contained in Sesbania roots, shoots and roots plus shoots, respectively. The beneficial effects of Sesbania residues are attributed not only to the additional N availability to the plants, but also to effects on the enhancement of soil N uptake, particularly in the L+R treatment. The findings suggest that the use of Sesbania aculeata residues, as a green manure, can provide a substantial portion of total N in sorghum. In addition, the use of Sesbania green manure in salt-affected soils, as a bio-reclaiming material, can be a promising approach for enhancing plant growth on a sustainable basis. (author)

  7. Evaluation of method for phthalate extraction from milk related to milk dilution ratio

    Directory of Open Access Journals (Sweden)

    Milojković Danica S.

    2015-01-01

    Full Text Available Liquid-liquid extraction techniques were compared coupled with gas chromatography-mass spectrometry (GC-MS, for the extraction and the determination of four phthalates: dimethyl phthalate (DMP, di-n-butyl phthalate (DBP, benzyl butyl phthalate (BBP and di-(2-ethylhexyl phthalate (DEHP in six different kinds of milk-based samples. Extraction factors: sample preparation, organic solvent type and volume, salt effect, agitation and the extraction time were optimized. The ion of base peaks (m/z 149 for DBP, BBP and DEHP and m/z 163 for DMP for investigated phthalates were selected for the screening studies. The acquisition was performed at the selected ion monitoring mode. The MSD response for GC-MS phthalate calibration standards was linear between 0.25 and 2.50 μg mL-1 with calculated LODs between 0.01 μg mL-1 to 0.04 μg mL-1 and LOQs of 0.05 μg mL-1 to 0.12 μg mL-1, while repeatability was between 1.7 % to 4.9 % RSD. The study demonstrated an increase of the recovery of less polar phthalates in matrix milk standards by matrix dilution. Recovery for hydrophilic phthalates, like DMP, was not changed by matrix dilution and it was continuously low for the investigated method. Two spiking levels were tested for influence of matrix dilution on phthalate recovery, showed the same trend. [Projekat Ministarstva nauke Republike Srbije, br. 31060

  8. Multi-element isotope dilution analyses using ICP-MS

    International Nuclear Information System (INIS)

    Volpe, A.M.

    1996-01-01

    Presently, 37 elements ranging from light (Li,B) through transition metals, noble, rare earth and heavy elements, to actinides and transuranics (Pu, Am, Cm) are measured by isotope dilution at Lawrence Livermore National Laboratory. Projects range from geological and hydrological to biological. The research goal is to measure accurately many elements present in diverse matrices at trace (ppb) levels using isotope dilution methods. Major advantages of isotope dilution methods are accuracy, elimination of ion intensity calibration, and quantitation for samples that require chemical separation. Accuracy depends on tracer isotope calibration, tracer-sample isotopic equilibration, and appropriate background, isobaric and mass bias corrections. Propagation of isotope ratio error due to improper tracer isotope addition is a major concern with multi-element analyses when abundances vary widely. 11 refs., 3 figs

  9. Dilute scintillators for large-volume tracking detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reeder, R.A. (University of New Mexico, Albuquerque, NM (United States)); Dieterle, B.D. (University of New Mexico, Albuquerque, NM (United States)); Gregory, C. (University of New Mexico, Albuquerque, NM (United States)); Schaefer, F. (University of New Mexico, Albuquerque, NM (United States)); Schum, K. (University of New Mexico, Albuquerque, NM (United States)); Strossman, W. (University of California, Riverside, CA (United States)); Smith, D. (Embry-Riddle Aeronautical Univ., Prescott, AZ (United States)); Christofek, L. (Los Alamos National Lab., NM (United States)); Johnston, K. (Los Alamos National Lab., NM (United States)); Louis, W.C. (Los Alamos National Lab., NM (United States)); Schillaci, M. (Los Alamos National Lab., NM (United States)); Volta, M. (Los Alamos National Lab., NM (United States)); White, D.H. (Los Alamos National Lab., NM (United States)); Whitehouse, D. (Los Alamos National Lab., NM (United States)); Albert, M. (University of Pennsylvania, Phi

    1993-10-01

    Dilute scintillation mixtures emit isotropic light for both fast and slow particles, but retain the Cherenkov light cone from fast particles. Large volume detectors using photomultipliers to reconstruct relativistic tracks will also be sensitive to slow particles if they are filled with these mixtures. Our data show that 0.03 g/l of b-PBD in mineral oil has a 2.4:1 ratio (in the first 12 ns) of isotropic light to Cherenkov light for positron tracks. The light attenuation length is greater than 15 m for wavelength above 400 nm, and the scintillation decay time is about 2 ns for the fast component. There is also a slow isotropic light component that is larger (relative to the fast component) for protons than for electrons. This effect allows particle identification by a technique similar to pulse shape discrimination. These features will be utilized in LSND, a neutrino detector at LAMPF. (orig.)

  10. Attentional sets influence perceptual load effects, but not dilution effects.

    Science.gov (United States)

    Benoni, Hanna; Zivony, Alon; Tsal, Yehoshua

    2014-01-01

    Perceptual load theory [Lavie, N. (1995). Perceptual load as a necessary condition for selective attention. Journal of Experimental Psychology: Human Perception and Performance, 21, 451-468.; Lavie, N., & Tsal, Y. (1994) Perceptual load as a major determinant of the locus of selection in visual attention. Perception & Psychophysics, 56, 183-197.] proposes that interference from distractors can only be avoided in situations of high perceptual load. This theory has been supported by blocked design manipulations separating low load (when the target appears alone) and high load (when the target is embedded among neutral letters). Tsal and Benoni [(2010a). Diluting the burden of load: Perceptual load effects are simply dilution effects. Journal of Experimental Psychology: Human Perception and Performance, 36, 1645-1656.; Benoni, H., & Tsal, Y. (2010). Where have we gone wrong? Perceptual load does not affect selective attention. Vision Research, 50, 1292-1298.] have recently shown that these manipulations confound perceptual load with "dilution" (the mere presence of additional heterogeneous items in high-load situations). Theeuwes, Kramer, and Belopolsky [(2004). Attentional set interacts with perceptual load in visual search. Psychonomic Bulletin & Review, 11, 697-702.] independently questioned load theory by suggesting that attentional sets might also affect distractor interference. When high load and low load were intermixed, and participants could not prepare for the presentation that followed, both the low-load and high-load trials showed distractor interference. This result may also challenge the dilution account, which proposes a stimulus-driven mechanism. In the current study, we presented subjects with both fixed and mixed blocks, including a mix of dilution trials with low-load trials and with high-load trials. We thus separated the effect of dilution from load and tested the influence of attentional sets on each component. The results revealed that whereas

  11. Interaction Studies of Dilute Aqueous Oxalic Acid

    Directory of Open Access Journals (Sweden)

    Kiran Kandpal

    2007-01-01

    Full Text Available Molecular conductance λm, relative viscosity and density of oxalicacid at different concentration in dilute aqueous solution were measured at 293 K.The conductance data were used to calculate the value association constant.Viscosity and density data were used to calculate the A and B coefficient ofJone-Dole equation and apparent molar volume respectively. The viscosityresults were utilized for the applicability of Modified Jone-Dole equation andStaurdinger equations. Mono oxalate anion acts, as structure maker and thesolute-solvent interaction were present in the dilute aqueous oxalic acid.

  12. The Melt-Dilute Treatment Technology Offgas Development Status Report

    International Nuclear Information System (INIS)

    Adams, T. M.

    1999-01-01

    The melt-dilute treatment technology is being developed to facilitate the ultimate disposition of highly enriched Al-Base DOE spent nuclear fuels in a geologic repository such as that proposed for Yucca Mountain. The melt-dilute process is a method of preparing DOE spent nuclear fuel for long term storage

  13. An assessment of the dilution required to mitigate Hanford tank 241-SY-101

    International Nuclear Information System (INIS)

    Hudson, J.D.; Bredt, P.R.; Felmy, A.R.; Stewart, C.W.; Tingey, J.M.; Trent, D.S.; Barney, G.S.; Herting, D.L.; Larrick, A.P.; Reynolds, D.A.

    1995-02-01

    A group of experts from PNL and WHC convened November 2 and 3, 1994, to screen the current state of knowledge about dilution and reach a consensus on the minimum dilution ratio that will achieve passive mitigation of Tank 241-SY-101 wastes and the dilution ratio that would satisfy the given cross-site transfer criteria with reasonable assurance. The panel evaluated the effects of dilution on the parameters important in gas generation, retention, and release and reached the following conclusions, which are deduced from the existing body of data, experience, and analyses: (1) Dissolution of solids is the single most important aspect of mitigation by dilution. We are confident that diluting until nitrates, nitrites, and aluminum salts are dissolved will mitigate Hanford flammable gas tanks; (2) Sufficient solids dissolution can be achieved in Tank 241-SY-101 at a dilution ratio of 1:1, which will result in a average specific gravity of approximately 1.35. It is likely that a 0.5:1 dilution will also mitigate 241-SY-101, but the current uncertainty is too high to recommend this dilution ratio; (3) The recommended dilution requires a diluent with at least 2 molar free hydroxide, because aluminum probably precipitates at lower hydroxide concentrations. The transfer criteria for Tank 241-SY-101 waste were also evaluated. These criteria have been specified as solids content ≤30% (volume), viscosity ≤30% cP and density <1.5 g/mL. (1) Solids content is the limiting criterion if it is defined as volume fraction of settled solids. A 1:1 dilution will satisfy this criterion at nominal premixing conditions in Tank 241-SY-101; however, analysis of Window E core samples suggests that up to 1.5:1 might be required. If the solids content is interpreted simply as solids volume fraction no further dilution is necessary, because Tank 241-SY-101 waste (excluding the crust) is already below 30%; (2) Bulk density is the next limiting criterion and is met at 0.4:1 dilution

  14. Improving the Efficiency of 3-D Hydrogeological Mixers: Dilution Enhancement Via Coupled Engineering-Induced Transient Flows and Spatial Heterogeneity

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe P. J.; Fiori, Aldo; Bellin, Alberto

    2018-03-01

    Natural attenuation and in situ oxidation are commonly considered as low-cost alternatives to ex situ remediation. The efficiency of such remediation techniques is hindered by difficulties in obtaining good dilution and mixing of the contaminant, in particular if the plume deformation is physically constrained by an array of wells, which serves as a containment system. In that case, dilution may be enhanced by inducing an engineered sequence of injections and extractions from such pumping system, which also works as a hydraulic barrier. This way, the aquifer acts as a natural mixer, in a manner similar to the industrialized engineered mixers. Improving the efficiency of hydrogeological mixers is a challenging task, owing to the need to use a 3-D setup while relieving the computational burden. Analytical solutions, though approximated, are a suitable and efficient tool to seek the optimum solution among all possible flow configurations. Here we develop a novel physically based model to demonstrate how the combined spatiotemporal fluctuations of the water fluxes control solute trajectories and residence time distributions and therefore, the effectiveness of contaminant plume dilution and mixing. Our results show how external forcing configurations are capable of inducing distinct time-varying groundwater flow patterns which will yield different solute dilution rates.

  15. Initial magnetic susceptibility of the diluted magnetopolymer elastic composites

    International Nuclear Information System (INIS)

    Borin, D.Yu.; Odenbach, S.

    2017-01-01

    In this work diluted magnetopolymer elastic composites based on magnetic microparticles are experimentally studied. Considered samples have varied concentration of the magnetic powder and different structural anisotropy. Experimental data on magnetic properties are accomplished by microstructural observations performed using X-Ray tomography. Influence of the particles amount and structuring effects on the initial magnetic susceptibility of the composites as well as the applicability of the Maxwell-Garnett approximation, which is widely used in considerations of magnetopolymer elastic composites, are evaluated. It is demonstrated that the approximation works well for diluted samples containing randomly distributed magnetic particles and for the diluted samples with chain-like structures oriented perpendicular to an externally applied field, while it fails to predict the susceptibility of the samples with structures oriented parallel to the field. Moreover, it is shown, that variation of the chains morphology does not significantly change the composite initial magnetic susceptibility. - Highlights: • The Maxwell-Garnet prediction works well for the diluted isotropic composites. • The Maxwell-Garnet prediction can be used for composites with structures oriented perpendicular to an applied field. • Chains oriented parallel to an applied field significantly increase the composite initial magnetic susceptibility. • The number and thickness of chains is not of the highest importance for the diluted composites. • The crucial reason of the observed effect is expected to be the demagnetisation factor of the chains.

  16. Dilution physics modeling: Dissolution/precipitation chemistry

    International Nuclear Information System (INIS)

    Onishi, Y.; Reid, H.C.; Trent, D.S.

    1995-09-01

    This report documents progress made to date on integrating dilution/precipitation chemistry and new physical models into the TEMPEST thermal-hydraulics computer code. Implementation of dissolution/precipitation chemistry models is necessary for predicting nonhomogeneous, time-dependent, physical/chemical behavior of tank wastes with and without a variety of possible engineered remediation and mitigation activities. Such behavior includes chemical reactions, gas retention, solids resuspension, solids dissolution and generation, solids settling/rising, and convective motion of physical and chemical species. Thus this model development is important from the standpoint of predicting the consequences of various engineered activities, such as mitigation by dilution, retrieval, or pretreatment, that can affect safe operations. The integration of a dissolution/precipitation chemistry module allows the various phase species concentrations to enter into the physical calculations that affect the TEMPEST hydrodynamic flow calculations. The yield strength model of non-Newtonian sludge correlates yield to a power function of solids concentration. Likewise, shear stress is concentration-dependent, and the dissolution/precipitation chemistry calculations develop the species concentration evolution that produces fluid flow resistance changes. Dilution of waste with pure water, molar concentrations of sodium hydroxide, and other chemical streams can be analyzed for the reactive species changes and hydrodynamic flow characteristics

  17. Determination of the interchangeable heavy-metal fraction in soils by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Gaebler, H.E.; Bahr, A.; Mieke, B.

    1999-01-01

    An isotope dilution technique using enriched stable isotopes is applied to determine the interchangeable heavy-metal fraction in soils. Metals in two soil samples are extracted at constant pH, with water, NH 4 NO 3 , and EDTA. A spike of enriched stable isotopes is added to the suspension of sample and eluant at the beginning of the extraction. The heavy-metal fraction which exchanges with the added spike during the extraction is called the interchangeable fraction. The extractable heavy-metal fractions are obtained from the heavy-metal concentrations in the eluates. Isotope ratios and concentrations are determined by HR-ICP-MS. The isotope dilution technique described enables both the extractable and the interchangeable heavy-metal fractions to be determined in the same experiment. The combination of both results gives additional information on elemental availability under different conditions that cannot be obtained by analyzing the extractable heavy-metal fractions alone. It is demonstrated that in some cases different eluants just shift the distribution of the interchangeable fraction of an element between the solid and liquid phases (e.g., Pb and Cd in a topsoil sample) while the amount of the interchangeable fraction itself remains constant. For other elements, as Ni, Zn, and Cr, the use of different eluants (different pH, complexing agents) sometimes enlarges the interchangeable fraction. (orig.)

  18. Enhancement of surface magnetism due to bulk bond dilution

    International Nuclear Information System (INIS)

    Tsallis, C.; Sarmento, E.F.; Albuquerque, E.L. de

    1985-01-01

    Within a renormalization group scheme, the phase diagram of a semi-infinite simple cubic Ising ferromagnet is discussed, with arbitrary surface and bulk coupling constants, and including possible dilution of the bulk bonds. It is obtained that dilution makes easier the appearance of surface magnetism in the absence of bulk magnetism. (Author) [pt

  19. In-gel multiple displacement amplification of long DNA fragments diluted to the single molecule level.

    Science.gov (United States)

    Michikawa, Yuichi; Sugahara, Keisuke; Suga, Tomo; Ohtsuka, Yoshimi; Ishikawa, Kenichi; Ishikawa, Atsuko; Shiomi, Naoko; Shiomi, Tadahiro; Iwakawa, Mayumi; Imai, Takashi

    2008-12-15

    The isolation and multiple genotyping of long individual DNA fragments are needed to obtain haplotype information for diploid organisms. Limiting dilution of sample DNA followed by multiple displacement amplification is a useful technique but is restricted to short (reaction (PCR)-ready form. The haplotypes of seven SNPs spanning 240 kb of the DNA surrounding the human ATM gene region on chromosome 11 were determined for 10 individuals, demonstrating the feasibility of this new method.

  20. Phase diagrams of site diluted ferromagnetic thin film

    International Nuclear Information System (INIS)

    Hamedoun, M.; Bouslykhane, K.; Bakrim, H.; Hourmatallah, A.; Benzakour, N.; Masrour, R.

    2006-01-01

    The phase transition properties of Ising, classical XY and Heisenberg of diluted ferromagnetic thin film are studied by the method of exact high-temperature series expansions extrapolated with the Pade approximants method. The reduced critical temperature τ c of the diluted ferromagnetic thin films is studied as a function of film thickness L and the exchange interactions in the bulk J b , in the surface J s and between surface and nearest-neighbour layer J - bar . It is found that τ c increases with the exchange interactions of surface and L. The magnetic phase diagram (τ c versus dilution x) is obtained. A critical value of the surface exchange interaction above which the surface magnetism appears is obtained. The dependence of the critical parameter of surface reduced coupling R 2 c as a function of the dilution x and the ratio of the exchange interaction between the surface and nearest-neighbour layer to the bulk one R 1 for the three studied models has been investigated. The percolation threshold is defined as the concentration x p at which τ c =0. The obtained values are x p ∼0.2 in the bulk and x p ∼0.4 at the surface

  1. A Study on the Stability of Diluted Bee Venom Solution

    Directory of Open Access Journals (Sweden)

    Mi-Suk Kang

    2003-06-01

    Full Text Available Objective : The purpose of this study was to investigate the stability of bee venom according to the keeping method and period. Method : The author observed microbial contamination of bee venom in nutrient agar, broth, YPD agar and YPD media and antibacterial activity for S. aureus, E. coli manufactured 12, 6 and 3 months ago as the two type of room temperature and 4℃ cold storage. Result : 1. 1:3,000 and 1:4,000 diluted bee venom solution did not show microbial contamination both room temperature and cold storage within twelve months. 2. There was antibacterial activity of diluted bee venom for S. aureus in cold storage within twelve months and there was no antibacterial activity of diluted bee venom for S. aureus in twelve months, room temperature storage. 3. We could not observe the zone of inhibition around paper disc of all for E.coli. in 1:3,000, 1:30,000 and 1:3,000,000 diluted bee venom solution, respectively. According to results, we expect that diluted bee venom solution is stable both cold and room temperature storage within twelve months.

  2. Effects of hydrogen addition and nitrogen dilution on the laminar flame characteristics of premixed methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tahtouh, T.; Halter, F.; Mounaim-Rousselle, C. [Institut PRISME, Universite d' Orleans, 8 rue Leonard de Vinci-45072, Orleans Cedex 2 (France); Samson, E. [PSA Peugeot Citroen (France)

    2009-10-15

    The effect of hydrogen addition and nitrogen dilution on laminar flame characteristics was investigated. The spherical expanding flame technique, in a constant volume bomb, was employed to extract laminar flame characteristics. The mole fraction of hydrogen in the methane-hydrogen mixture was varied from 0 to 1 and the mole fraction of nitrogen in the total mixture (methane-hydrogen-air-diluent) from 0 to 0.35. Measurements were performed at an initial pressure of 0.1 MPa and an initial temperature of 300 K. The mixtures investigated were under stoichiometric conditions. Based on experimental measurements, a new correlation for calculating the laminar burning velocity of methane-hydrogen-air-nitrogen mixtures is proposed. The laminar burning velocity was found to increase linearly with hydrogen mass fraction for all dilution ratios while the burned gas Markstein length decreases with the increase in hydrogen amount in the mixture except for high hydrogen mole fractions (>0.6). Nitrogen dilution has a nonlinear reducing effect on the laminar burning velocity and an increasing effect on the burned gas Markstein length. The experimental results and the proposed correlation obtained are in good agreement with literature values. (author)

  3. Thermal diffusion in dilute nanofluids investigated by photothermal interferometry

    International Nuclear Information System (INIS)

    Philip, J; Nisha, M R

    2010-01-01

    We have carried out a theoretical analysis of the dependence of the particle mass fraction on the thermal diffusivity of dilute suspensions of nanoparticles in liquids (dilute nanofluids). The analysis takes in to account adsorption of an ordered layer of solvent molecules around the nanoparticles. It is found that thermal diffusivity decreases with mass fraction for sufficiently small particle sizes. Beyond a critical particle size thermal diffusivity begins to increase with mass fraction for the same system. The results have been verified experimentally by measuring the thermal diffusivity of dilute suspensions of TiO 2 nanoparticles dispersed in polyvinyl alcohol (PVA) medium. The effect is attributed to Kapitza resistance of thermal waves in the medium.

  4. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Li Xue; Fang Xiaowei; Yu Zhiqiang; Sheng Guoying; Wu Minghong; Fu Jiamo; Chen Huanwen

    2012-01-01

    Highlights: ► High throughput analysis of urinary creatinine is achieved by using ID-EESI–MS/MS. ► Urine sample is directly analyzed and no sample pre-treatment is required. ► Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI–MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 μg L −1 . Over the concentration range investigated (0.05–10 mg L −1 ), the calibration curve was obtained with satisfactory linearity (R 2 = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1–11.8% (n = 6) and 4.1–11.3% (n = 6), respectively. The isotope dilution EESI–MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85–111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI–MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  5. Determination of infinite dilution activity coefficients using HS-SPME/GC/FID for hydrocarbons in furfural at temperatures of (298.15, 308.15, and 318.15) K

    International Nuclear Information System (INIS)

    Arantes Furtado, Filipe; Vieira Coelho, Gerson Luiz

    2012-01-01

    Highlights: ► Two approaches were proposed using SPME on determination of infinite dilution activity coefficients. ► Infinite dilution activity coefficients of nine solutes in solvent furfural at T = (298.15, 308.15, and 318.15) K. ► Fiber–gas partition coefficients of nine solutes on PDMS at T = (298.15, 308.15, and 318.15) K. ► Optical microscopy analysis and statistical tests to measure possible damages on fiber coating. ► Advantages and limitations of methodology proposed were discussed. - Abstract: A new methodology using the headspace solid phase microextraction (HS-SPME) technique has been used to evaluate the infinite dilution activity coefficient (γ 12 ∞ ) of nine hydrocarbons (alkanes, cycloalkanes, and aromatics) in furfural solvent. The main objective of this study was to validate a faster and lower cost methodology expanding the use of HS-SPME to determine infinite dilution activity of solutes in organic solvents. Two approaches were proposed for the determination of γ 12 ∞ in order to use this technique (HS-SPME). In addition, the fiber–gas partition coefficients (K fg ) for each analyte at each of the studied temperatures were determined. The activity and partition coefficients have been reported at temperatures of (298.15, 308.15, and 318.15) K. The data were compared with the literature infinite dilution data determined by other methods such as liquid–gas chromatography (GLC) and gas stripping. Partial molar excess enthalpies of mixing at infinite dilution for each solute have been determined. The fibers were tested before and after each experiment, using statistical methods to ensure that their properties do not change during the experiments. The fibers were also analyzed by optical microscopy to evaluate possible surface damage by comparing them with new fibers. The activity coefficient values correlated well with the data in the literature and showed average deviations less than 10%.

  6. Computer registration of radioactive indicator-dilution curves.

    Science.gov (United States)

    Shepherd, A P; Perry, M A; Alexander, G M; Granger, D N; Riedel, G L; Kvietys, P R; Franke, C P

    1983-12-01

    A system is described for recording indicator-dilution curves produced by gamma radiation-emitting tracers. The system consists of a flow-through cuvette in a well counter, appropriate commercially available gamma radiation-detecting equipment, an Apple II computer, and a two-channel pulse-counting interface of our own design. With the counting interface and the software described here, an investigator can simultaneously record two indicator-dilution curves produced by gamma emitters. Instead of having to wait hours or days for results, the investigator can watch the data being recorded and display the results in graphic form almost immediately after each injection.

  7. Moderate Dilution of Copper Slag by Natural Gas

    Science.gov (United States)

    Zhang, Bao-jing; Zhang, Ting-an; Niu, Li-ping; Liu, Nan-song; Dou, Zhi-he; Li, Zhi-qiang

    2018-01-01

    To enable use of copper slag and extract the maximum value from the contained copper, an innovative method of reducing moderately diluted slag to smelt copper-containing antibacterial stainless steel is proposed. This work focused on moderate dilution of copper slag using natural gas. The thermodynamics of copper slag dilution and ternary phase diagrams of the slag system were calculated. The effects of blowing time, temperature, matte settling time, and calcium oxide addition were investigated. The optimum reaction conditions were identified to be blowing time of 20 min, reaction temperature of 1250°C, settling time of 60 min, CaO addition of 4% of mass of slag, natural gas flow rate of 80 mL/min, and outlet pressure of 0.1 MPa. Under these conditions, the Fe3O4 and copper contents of the residue were 7.36% and 0.50%, respectively.

  8. Tricritical behavior in the diluted transverse spin-1 Ising model with a longitudinal crystal field

    International Nuclear Information System (INIS)

    Htoutou, K.; Oubelkacem, A.; Ainane, A.; Saber, M.

    2005-01-01

    The transverse spin-1 Ising model with a longitudinal crystal field exhibits a tricritical behavior. Within the effective field theory with a probability distribution technique that accounts for the self-spin correlations, we have studied the influence of site dilution on this behavior and have calculated the temperature-transverse field-longitudinal crystal field-concentration phase diagrams and determined, in particular, the influence of the concentration of magnetic atoms c on the tricritical behavior. We have found that the tricritical point appears for large values of the concentration c of magnetic atoms and disappears with the increase in dilution (small values of c). Results for square lattice are calculated numerically and some interesting results are obtained. In certain ranges of values of the strength of the longitudinal crystal field D/J when it becomes sufficiently negative, we found re-entrant phenomenon, which disappears with increase in the value of the strength of the transverse field

  9. Dilution in Transition Zone between Rising Plumes and Surface Plumes

    DEFF Research Database (Denmark)

    Larsen, Torben

    2004-01-01

    The papers presents some physical experiments with the dilution of sea outfall plumes with emphasize on the transition zone where the relative fast flowing vertical plume turns to a horizontal surface plume following the slow sea surface currents. The experiments show that a considerable dilution...

  10. The dilute random field Ising model by finite cluster approximation

    International Nuclear Information System (INIS)

    Benyoussef, A.; Saber, M.

    1987-09-01

    Using the finite cluster approximation, phase diagrams of bond and site diluted three-dimensional simple cubic Ising models with a random field have been determined. The resulting phase diagrams have the same general features for both bond and site dilution. (author). 7 refs, 4 figs

  11. Chiral-glass transition in a diluted dipolar-interaction Heisenberg system

    International Nuclear Information System (INIS)

    Zhang Kaicheng; Liu Guibin; Zhu Yan

    2011-01-01

    Recently, numerical simulations reveal that a spin-glass transition can occur in the three-dimensional diluted dipolar system. By defining the chirality of triple spins in a diluted dipolar Heisenberg spin glass, we study the chiral ordering in the system using parallel tempering algorithm and heat bath method. The finite-size scaling analysis reveals that the system undergoes a chiral-glass transition at finite temperature. - Highlights: → We define the chirality in a diluted dipolar Heisenberg system. → The system undergoes a chiral-glass transition at finite temperature. → We extract the critical exponents of the chiral-glass transition.

  12. Effect of dietary dilution of energy and nutrients during different ...

    African Journals Online (AJOL)

    A completely randomized design was conducted to evaluate the effect of dietary dilution of energy and nutrients during different growing periods on compensatory growth of Ross broilers. Four replicant pens were assigned per seven treatments. Chicks in each treatment received concentrated and diluted diets in different ...

  13. Computer automation of a dilution cryogenic system

    International Nuclear Information System (INIS)

    Nogues, C.

    1992-09-01

    This study has been realized in the framework of studies on developing new technic for low temperature detectors for neutrinos and dark matter. The principles of low temperature physics and helium 4 and dilution cryostats, are first reviewed. The cryogenic system used and the technic for low temperature thermometry and regulation systems are then described. The computer automation of the dilution cryogenic system involves: numerical measurement of the parameter set (pressure, temperature, flow rate); computer assisted operating of the cryostat and the pump bench; numerical regulation of pressure and temperature; operation sequence full automation allowing the system to evolve from a state to another (temperature descent for example)

  14. Composite systems of dilute and dense couplings

    International Nuclear Information System (INIS)

    Raymond, J R; Saad, D

    2008-01-01

    Composite systems, where couplings are of two types, a combination of strong dilute and weak dense couplings of Ising spins, are examined through the replica method. The dilute and dense parts are considered to have independent canonical disordered or uniform bond distributions; mixing the models by variation of a parameter γ alongside inverse temperature β we analyse the respective thermodynamic solutions. We describe the variation in high temperature transitions as mixing occurs; in the vicinity of these transitions we exactly analyse the competing effects of the dense and sparse models. By using the replica symmetric ansatz and population dynamics we described the low temperature behaviour of mixed systems

  15. Enhancement of the electrical characteristics of MOS capacitors by reducing the organic content of H2O-diluted Spin-On-Glass based oxides

    International Nuclear Information System (INIS)

    Molina, Joel; Munoz, Ana; Torres, Alfonso; Landa, Mauro; Alarcon, Pablo; Escobar, Manuel

    2011-01-01

    In this work, the physical, chemical and electrical properties of Metal-Oxide-Semiconductor (MOS) capacitors with Spin-On-Glass (SOG)-based thin films as gate dielectric have been investigated. Experiments of SOG diluted with two different solvents (2-propanol and deionized water) were done in order to reduce the viscosity of the SOG solution so that thinner films (down to ∼20 nm) could be obtained and their general characteristics compared. Thin films of SOG were deposited on silicon by the sol-gel technique and they were thermally annealed using conventional oxidation furnace and Rapid Thermal Processing (RTP) systems within N 2 ambient after deposition. SOG dilution using non-organic solvents like deionized water and further annealing (at relatively high temperatures ≥450 deg. C) are important processes intended to reduce the organic content of the films. Fourier-Transform Infrared (FTIR) Spectroscopy results have shown that water-diluted SOG films have a significant reduction in their organic content after increasing annealing temperature and/or dilution percentage when compared to those of undiluted SOG films. Both current-voltage (I-V) and capacitance-voltage (C-V) measurements show better electrical characteristics for SOG-films diluted in deionized water compared to those diluted in 2-propanol (which is an organic solvent). The electrical characteristics of H 2 O-diluted SOG thin films are very similar to those obtained from high quality thermal oxides so that their application as gate dielectrics in MOS devices is promising. Finally, it has been demonstrated that by reducing the organic content of SOG-based thin films, it is possible to obtain MOS devices with better electrical properties.

  16. Aluminium. II - A review of deformation properties of high purity aluminium and dilute aluminium alloys.

    Science.gov (United States)

    Reed, R. P.

    1972-01-01

    The elastic and plastic deformation behavior of high-purity aluminum and of dilute aluminum alloys is reviewed. Reliable property data, including elastic moduli, elastic coefficients, tensile, creep, fatigue, hardness, and impact are presented. Single crystal tensile results are discussed. Rather comprehensive reference lists, containing publications of the past 20 years, are included for each of the above categories. Defect structures and mechanisms responsible for mechanical behavior are presented. Strengthening techniques (alloys, cold work, irradiation, quenching, composites) and recovery are briefly reviewed.

  17. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam

    2014-05-20

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both temperature and soot measurements presented are line-of-sight averages. The results aid in understanding the kinetic and thermodynamic behavior of the soot formation and oxidation chemistry with changes in diluents, ultimately leading to possible methods of reducing soot emission from practical combustion hardware. The diluted fuel and coflow exit velocities (top-hat profiles) were matched at all pressures to minimize shear effects. In addition to the velocity-matched flow rates, the mass fluxes were held constant for all pressures. Addition of a diluent has a pronounced effect on both the soot surface temperature and volume fraction, with the helium diluted flame yielding the maximum and carbon dioxide diluted flame yielding minimum soot surface temperature and volume fraction. At low pressures, peak soot volume fraction exists at the tip of the flame, and with an increase in pressure, the location shifts lower to the wings of the flame. Due to the very high diffusivity of helium, significantly higher temperature and volume fraction are measured and explained. Carbon dioxide has the most dramatic soot suppression effect. By comparing the soot yield with previously measured soot precursor concentrations in the same flame, it is clear that the lower soot yield is a result of enhanced oxidation rates rather than a reduction in precursor formation. Copyright © 2014 Taylor & Francis Group, LLC.

  18. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Xue [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Fang Xiaowei [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Yu Zhiqiang; Sheng Guoying [Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Wu Minghong [Shanghai Applied Radiation Institute, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Fu Jiamo [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Chen Huanwen, E-mail: chw8868@gmail.com [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China)

    2012-10-20

    Highlights: Black-Right-Pointing-Pointer High throughput analysis of urinary creatinine is achieved by using ID-EESI-MS/MS. Black-Right-Pointing-Pointer Urine sample is directly analyzed and no sample pre-treatment is required. Black-Right-Pointing-Pointer Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI-MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 {mu}g L{sup -1}. Over the concentration range investigated (0.05-10 mg L{sup -1}), the calibration curve was obtained with satisfactory linearity (R{sup 2} = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1-11.8% (n = 6) and 4.1-11.3% (n = 6), respectively. The isotope dilution EESI-MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85-111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI-MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  19. The IDA-80 measurement evaluation programme on mass spectrometric isotope dilution analysis of uranium and plutonium. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Golly, W.; Spannagel, G.; Kernforschungszentrum Karlsruhe G.m.b.H.; Bievre, P. de; Wolters, W.

    1984-12-01

    The main objective was the acquisition of basic data on the uncertainties involved in the mass spectrometric isotope dilution analysis as applied to the determination of uranium and plutonium in active feed solutions of reprocessing plants. The element concentrations and isotopic compositions of all test materials used were determined by CBNM and NBS with high accuracy. The more than 60000 analytical data reported by the participating laboratories were evaluated by statistical methods applied mainly to the calculation of estimates of the variances for the different uncertainty components contributing to the total uncertainty of this analytical technique. Attention was given to such topics as sample ageing, influence of fission products, spike calibration, ion fractionation, Pu-241 decay correction, minor isotope measurement and errors in data transfer. Furthermore, the performance of the 'dried sample' technique and the 'in-situ' spiking method of undiluted samples of reprocessing fuel solution with U-235/Pu-242 metal alloy spikes, were tested successfully. Considerable improvement of isotope dilution analysis in this safeguards relevant application during the last decade is shown as compared to the results obtained in the IDA-72 interlaboratory experiment, organized by KfK in 1972 on the same subject. (orig./HP) [de

  20. Dynamics of dilute disordered models: A solvable case

    International Nuclear Information System (INIS)

    Semerjian, Guilhem; Cugliandolo, Leticia F.

    2003-09-01

    We study the dynamics of a dilute spherical model with two body interactions and random exchanges. We analyze the Langevin equations and we introduce a functional variational method to study generic dilute disordered models. A crossover temperature replaces the dynamic transition of the fully-connected limit. There are two asymptotic regimes, one determined by the central band of the spectral density of the interactions and a slower one determined by localized configurations on sites with high connectivity. We confront the behavior of this model to the one of real glasses. (author)

  1. Isotope correlation and mass spectrometry techniques for irradiated fuel assay

    International Nuclear Information System (INIS)

    Deron, S.

    1985-01-01

    This paper outlines the methods used to account for fissionable materials in irradiated nuclear fuel elements entering reprocessing plants. Verification is accomplished at three mass balance stations in the plant. Techniques employed fall into two categories: isotopic and isotope dilution analyses by mass spectometry and isotope correlation techniques. These methods are discussed in some detail

  2. Effect of Welding Parameters on Dilution and Weld Bead Geometry in Cladding

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The effect of pulsed gas metal arc welding (GMAW) variables on the dilution and weld bead geometry in cladding X65 pipeline steel with 316L stainless steel was studied. Using a full factorial method, a series of experiments were carried out to know the effect of wire feed rate, welding speed, distance between gas nozzle and plate, and the vertical angle of welding on dilution and weld bead geometry. The findings indicate that the dilution of weld metal and its dimension i.e. width, height and depth increase with the feed rate, but the contact angle of the bead decreases first and then increases. Meantime, welding speed has an opposite effect except for dilution. There is an interaction effect between welding parameters at the contact angle. The results also show forehand welding or decreasing electrode extension decrease the angle of contact. Finally,a mathematical model is contrived to highlight the relationship between welding variables with dilution and weld bead geometry.

  3. The phase diagrams and the order parameters of the diluted transverse superlattice with antiferromagnetic interface coupling

    International Nuclear Information System (INIS)

    Oubelkacem, A.; El Aouad, N.; Benaboud, A.; Saber, M.

    2004-01-01

    Using the effective field theory with a probability distribution technique that accounts for the self-spin correlation functions, the magnetic properties of the Ising superlattice consisting of two ferromagnetic materials A and B, with L a layers of diluted spins S a =((1)/(2)) and L b layers of diluted spins S b =1 in an applied transverse field Ω with antiferromagnetic interface coupling are examined. For fixed values of the reduced exchange interactions and the concentration c of magnetic atoms, the phase diagrams and the total magnetization for the superlattice are studied as a function of the transverse field and the temperature. We find a number of characteristic phenomena. In particular, the effect of the concentration c of magnetic atoms, the interlayer coupling and the transverse field on both the compensation temperature and the magnetization profiles are clarified. Some of them may be related to the experimental works of rare-earth (RE)/transition metal (TM) multilayer films

  4. Analysis of boron dilution in a four-loop PWR

    International Nuclear Information System (INIS)

    Sun, J.G.; Sha, W.T.

    1995-03-01

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four-loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plant is at hot standby and the reactor coolant system has been heated to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated and a sensitivity study is performed to assess the accuracy of the numerical modeling of the geometry of the reactor coolant system

  5. Exchange bias in diluted-antiferromagnet/antiferromagnet bilayers

    International Nuclear Information System (INIS)

    Mao, Zhongquan; Zhan, Xiaozhi; Chen, Xi

    2015-01-01

    The hysteresis-loop properties of a diluted-antiferromagnetic (DAF) layer exchange coupling to an antiferromagnetic (AF) layer are investigated by means of numerical simulations. Remarkable loop shift and coercivity enhancement are observed in such DAF/AF bilayers, while they are absent in the uncoupled DAF single layer. The influences of pinned domains, dilution, cooling field and DAF layer thickness on the loop shift are investigated systematically. The result unambiguously confirms an exchange bias (EB) effect in the DAF/AF bilayers. It also reveals that the EB effect originates from the pinned AF domains within the DAF layer. In contrast to conventional EB systems, frozen uncompensated spins are not found at the interface of the AF pinning layer. (paper)

  6. Field measurement program to determine far field plume dilution parameters

    International Nuclear Information System (INIS)

    Orth, R.C.; Carter, H.H.; Miyasaki, M.T.

    1974-01-01

    A description of the techniques used to obtain measurements of temperature, salinity, tidal velocity and tracer concentration required to determine the far field dilution in a shallow estuary is presented. The study was done to characterize the physical hydrography of the Bush River, a tributary estuary of the Chesapeake Bay, which is a possible recipient of the thermal discharge from a proposed power plant consisting of two 850 MWe nuclear generating units. Measurements of temperature and salinity along the axis of the estuary during periods of high and low fresh water inflow were obtained for use in the development of a one-dimensional-segmented transient state model of the estuary. Computer concentrations from the model compared favorably with measured dye concentrations for the same periods of high and low freshwater inflow

  7. Specific-heat measurements on dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Zeeuw, H.C.M. van der.

    1985-01-01

    The author measured the specific heat of dilute 3 He- 4 He mixtures in the concentration range from X = 1 x 10 -3 to X = 3 x 10 -3 and in the temperature range from 100 mK to 600 mK. This has been done by means of a thermal relaxation method. This method provides some interesting features and is applied, to our knowledge, for the first time to dilute 3 He- 4 He mixtures. To reach the required temperature range for our experiments a 4 He circulating 3 He- 4 He dilution refrigerator has been constructed. The results confirm the deviation of the 3 He contribution to the specific heat from the ideal Fermi gas behaviour. (Auth.)

  8. On the nitrogen isotope dilution analysis by means of the automated NA-5A type 15N-analyzer

    International Nuclear Information System (INIS)

    Faust, H.; Mueller, G.; Stoerl, H.J.

    1976-01-01

    The analytical conditions are investigated under which quantitative nitrogen determination through isotope dilution analysis is possible using the NA-5A type 15 N-analyzer. Calculation of the nitrogen quantity, estimation of the maximum error and the evaluation technique are considered in detail. Test analyses performed on ammonia, urea, and amino acid nitrogen model solutions labelled in different ways yielded good correspondence with preset values. This technique was applied to determine the nitrogen content of biomedical materials. A working scheme for direct quantitative determination of ammonia-N, urea-N, and total-N in urine is presented. (author)

  9. Physical modelling of a rapid boron dilution transient

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G.; Hemstroem, B.; Karlsson, R. [Vattenfall Utveckling AB, Aelvkarleby (Sweden); Jacobson, S. [Vattenfall AB, Ringhals, Vaeroebacka (Sweden)

    1995-09-01

    The analysis of boron dilution accidents in pressurised water reactors has traditionally assumed that mixing is instantaneous and complete everywhere, eliminating in this way the possibility of concentration inhomogeneities. Situations can nevertheless arise where a volume of coolant with a low boron concentration may eventually enter the core and generate a severe reactivity transient. The work presented in this paper deals with a category of Rapid Boron Dilution Events characterised by a rapid start of a Reactor Coolant Pump (RCP) with a plug of relatively unborated water present in the RCS pipe. Model tests have been made at Vattenfall Utveckling AB in a simplified 1:5 scale model of a Westinghouse PWR. Conductivity measurements are used to determine dimensionless boron concentration. The main purpose of this experimental work is to define an experimental benchmark against which a mathematical model can be tested. The final goal is to be able to numerically predict Boron Dilution Transients. This work has been performed as a part of a Co-operative Agreement with Electricite` de France (EDF).

  10. Improvement of sample preparation for input plutonium accountability measurement by isotope dilution gammy-ray spectroscopy

    International Nuclear Information System (INIS)

    Nishida, K.; Kuno, Y.; Sato, S.; Masui, J.; Li, T.K.; Parker, J.L.; Hakkila, E.A.

    1992-01-01

    The sample preparation method for the isotope dilution gamma-ray spectrometry (IDGS) technique has been further improved for simultaneously determining the plutonium concentration and isotopic composition of highly irradiated spent-fuel dissolver solutions. The improvement includes using ion-exchange filter papers (instead of resin beads, as in two previous experiments) for better separation and recovery of plutonium from fission products. The results of IDGS measurements for five dissolver solutions are in good agreement with those by mass spectrometry with ∼0.4% for plutonium concentration and ∼0.1% for 239 Pu isotopic composition. The precision of the plutonium concentration is ∼1% with a 1-h count time. The technique could be implemented as an alternative method for input accountability and verification measurements in reprocessing plants

  11. Dilution correction equation revisited: The impact of stream slope, relief ratio and area size of basin on geochemical anomalies

    Science.gov (United States)

    Shahrestani, Shahed; Mokhtari, Ahmad Reza

    2017-04-01

    Stream sediment sampling is a well-known technique used to discover the geochemical anomalies in regional exploration activities. In an upstream catchment basin of stream sediment sample, the geochemical signals originating from probable mineralization could be diluted due to mixing with the weathering material coming from the non-anomalous sources. Hawkes's equation (1976) was an attempt to overcome the problem in which the area size of catchment basin was used to remove dilution from geochemical anomalies. However, the metal content of a stream sediment sample could be linked to several geomorphological, sedimentological, climatic and geological factors. The area size is not itself a comprehensive representative of dilution taking place in a catchment basin. The aim of the present study was to consider a number of geomorphological factors affecting the sediment supply, transportation processes, storage and in general, the geochemistry of stream sediments and their incorporation in the dilution correction procedure. This was organized through employing the concept of sediment yield and sediment delivery ratio and linking such characteristics to the dilution phenomenon in a catchment basin. Main stream slope (MSS), relief ratio (RR) and area size (Aa) of catchment basin were selected as the important proxies (PSDRa) for sediment delivery ratio and then entered to the Hawkes's equation. Then, Hawkes's and new equations were applied on the stream sediment dataset collected from Takhte-Soleyman district, west of Iran for Au, As and Sb values. A number of large and small gold, antimony and arsenic mineral occurrences were used to evaluate the results. Anomaly maps based on the new equations displayed improvement in anomaly delineation taking the spatial distribution of mineral deposits into account and could present new catchment basins containing known mineralization as the anomaly class, especially in the case of Au and As. Four catchment basins having Au and As

  12. Isotopic dilution requirements for 233U criticality safety in processing and disposal facilities

    International Nuclear Information System (INIS)

    Elam, K.R.; Forsberg, C.W.; Hopper, C.M.; Wright, R.Q.

    1997-11-01

    The disposal of excess 233 U as waste is being considered. Because 233 U is a fissile material, one of the key requirements for processing 233 U to a final waste form and disposing of it is to avoid nuclear criticality. For many processing and disposal options, isotopic dilution is the most feasible and preferred option to avoid nuclear criticality. Isotopic dilution is dilution of fissile 233 U with nonfissile 238 U. The use of isotopic dilution removes any need to control nuclear criticality in process or disposal facilities through geometry or chemical composition. Isotopic dilution allows the use of existing waste management facilities, that are not designed for significant quantities of fissile materials, to be used for processing and disposing of 233 U. The amount of isotopic dilution required to reduce criticality concerns to reasonable levels was determined in this study to be ∼ 0.66 wt% 233 U. The numerical calculations used to define this limit consisted of a homogeneous system of silicon dioxide (SiO 2 ), water (H 2 O), 233 U, and depleted uranium (DU) in which the ratio of each component was varied to determine the conditions of maximum nuclear reactivity. About 188 parts of DU (0.2 wt% 235 U) are required to dilute 1 part of 233 U to this limit in a water-moderated system with no SiO 2 present. Thus, for the US inventory of 233 U, several hundred metric tons of DU would be required for isotopic dilution

  13. Water Stress Scatters Nitrogen Dilution Curves in Wheat

    Directory of Open Access Journals (Sweden)

    Marianne Hoogmoed

    2018-04-01

    Full Text Available Nitrogen dilution curves relate a crop’s critical nitrogen concentration (%Nc to biomass (W according to the allometric model %Nc = a W-b. This model has a strong theoretical foundation, and parameters a and b show little variation for well-watered crops. Here we explore the robustness of this model for water stressed crops. We established experiments to examine the combined effects of water stress, phenology, partitioning of biomass, and water-soluble carbohydrates (WSC, as driven by environment and variety, on the %Nc of wheat crops. We compared models where %Nc was plotted against biomass, growth stage and thermal time. The models were similarly scattered. Residuals of the %Nc - biomass model at anthesis were positively related to biomass, stem:biomass ratio, Δ13C and water supply, and negatively related to ear:biomass ratio and concentration of WSC. These are physiologically meaningful associations explaining the scatter of biomass-based dilution curves. Residuals of the thermal time model showed less consistent associations with these variables. The biomass dilution model developed for well-watered crops overestimates nitrogen deficiency of water-stressed crops, and a biomass-based model is conceptually more justified than developmental models. This has implications for diagnostic and modeling. As theory is lagging, a greater degree of empiricism might be useful to capture environmental, chiefly water, and genotype-dependent traits in the determination of critical nitrogen for diagnostic purposes. Sensitivity analysis would help to decide if scaling nitrogen dilution curves for crop water status, and genotype-dependent parameters are needed.

  14. Human-milk intake measured by administration of deuterium oxide to the mother: a comparison with the test-weighing technique

    International Nuclear Information System (INIS)

    Butte, N.F.; Wong, W.W.; Patterson, B.W.; Garza, C.; Klein, P.D.

    1988-01-01

    A comparison was made between the dose-to-the-mother deuterium-dilution method and the conventional test-weighing technique for determining human-milk intake in five exclusively breast-fed infants and in four breast-fed infants who received supplemental foods. After administration of 2 H to the mothers human milk and infant urine were sampled over 14 d and analyzed for 2 H: 1 H ratios by gas-isotope-ratio mass spectrometry. Infant total body water was determined by 18 O dilution. The test-weighing procedure was conducted for 5 d consecutively. The intake of human milk (mean +/- SD) estimated by 2 H dilution was 648 +/- 63 g/d and estimated by test-weighing was 636 +/- 84 g/d. The mean difference between the two methods was not significantly different from 0. The 2 H-dilution and test-weighing techniques provide similar estimates of human-milk intake

  15. ERM booster vaccination of Rainbow trout using diluted bacterin

    DEFF Research Database (Denmark)

    Schmidt, Jacob Günther; Henriksen, Niels H.; Buchmann, Kurt

    2016-01-01

    under laboratory conditions extend the protection period. The present field study investigated the applicability of the method under practical farming conditions (freshwater earth ponds supplied by stream water). Primary immersion vaccination of trout (3–4 g) for 30 s in Y. ruckeri bacterin (diluted 1......Enteric Red Mouth Disease ERM caused by Yersinia ruckeri infection is associated with morbidity and mortality in salmonid farming but immersion vaccination of fry may confer some protection for a number of months. Revaccination of rainbow trout, even by use of diluted ERM immersion vaccine, can......:10) in April 2015 was followed 3 months later (July 2015) by 1 h bathing of rainbow trout in bacterin (diluted 1:650 or 1:1700) in order to evaluate if this time saving vaccination methodology can improve immunity and protection. Trout were subjected in farms to natural Y. ruckeri exposure in June and July...

  16. Introduction to the Physics of Diluted Magnetic Semiconductors

    CERN Document Server

    Gaj, Jan A

    2010-01-01

    The book deals with diluted magnetic semiconductors, a class of materials important to the emerging field of spintronics. In these materials semiconducting properties, both transport and optical, are influenced by the presence of magnetic ions. It concentrates on basic physical mechanisms (e.g. carrier-ion and ion-ion interactions) and resulting phenomena (e.g. magnetic polaron formation and spin relaxation). Introduction to the Physics of Diluted Magnetic Semiconductors is addressed to graduate-level and doctoral students and young researchers entering the field. The authors have been actively involved in the creation of this branch of semiconductor physics.

  17. Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

    Directory of Open Access Journals (Sweden)

    Jennifer L. Johns

    2018-02-01

    Full Text Available Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended.

  18. Dilution and slow injection reduces the incidence of rocuronium-induced withdrawal movements in children

    OpenAIRE

    Shin, Young Hee; Kim, Chung Su; Lee, Jong-Hwan; Sim, Woo Seog; Ko, Justin Sangwook; Cho, Hyun Sung; Jeong, Hui Yeon; Lee, Hye Won; Kim, Sang Hyun

    2011-01-01

    Background The aim of this study was to evaluate whether slow injection of diluted rocuronium could reduce rocuronium-induced withdrawal movements effectively in children. Methods After loss of consciousness, rocuronium 0.6 mg/kg was administered into 171 children according to the pre-assigned groups as follows: Group CF, injection of non-diluted rocuronium over 5 seconds; Group CS, injection of non-diluted rocuronium over 1 minute; Group DF, injection of diluted rocuronium (10 times) over 5 ...

  19. Heat pulses in dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Husson, L.P.J.

    1983-01-01

    The propagation of heat pulses in dilute 3 He- 4 He mixtures under pressure along a tube, which is long compared to its diameter, is discussed. At high temperatures, where the excitations are in local equilibrium with one another, the propagation of heat pulses in the liquid is determined by the phenomenon of second sound, which is essentially a density wave in the excitation gas. The velocity and attenuation of second sound can be determined from the shape of the transmitted pulse. Measurements on the scattering and absorption of phonons are presented, together with a detailed description of the experimental technique and the electronic equipment. Measurements on the velocity and absorption of second sound are presented. From the results for the velocity of second sound in pure 4 He, values of the phonon and roton parameters are deduced. The velocity data in the mixtures have been used to calculate values of the effective mass of 3 He in superfluid 4 He. The results of these calculations have been compared with values of the effective mass obtained by other authors. The coefficient of second-sound absorption in pure 4 He is computed from theory, making use of the phonon and roton parameters calculated from the second-sound velocity data in pure 4 He. The experimental results on the scattering and absorption of phonons have been analysed. The empirical expressions for the scattering and absorption rates obtained from the diffusive phonon signals were compared with the results of the Baym-Ebner theory, and have also been used to calculate the coefficient of thermal conductivity in dilute 3 He- 4 He mixtures. (Auth.)

  20. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material.

    Science.gov (United States)

    Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito

    2014-01-01

    The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.  

  1. Optimization in radiological protection; Otimizacao em radioprotecao

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Perez, Clarice de Freitas

    1996-07-01

    The optimization concept in radiation protection is, in its essence, practical. In each aspect that we deal with the man, it is necessary to take frequent decisions such as: what is the protection level to be pursued, since the protection levels under consideration provide doses lower than the appropriate annual limits. The optimization gives a basic framework of the minding that is appropriate to conduct to a balance kind of the resources available for the protection and protection level obtained against a multitude of factors and constrains in a manner to obtain the best result. In this work, was performed the optimization, from the radiation protection point of view, of a facility project who enclose two shielded hot cells where will be handled UO{sub 2} small plate with 50% of U-235 burn-up, irradiated in the research swimming pool reactor, IEA-R1. To obtain this goal were specified the relevant factors and criteria, were applied the main techniques used in a decision-making in radiological protection, presently adopted and was performed a sensibility study of the factors and criteria used in this work. In order to obtain a greater agility in applying the techniques for decision-making was developed a micro computer program. (author)

  2. Microstructure Related Characterization of a-Si:H Thin Films PECVD Deposited under Varied Hydrogen Dilution

    Directory of Open Access Journals (Sweden)

    Veronika Vavrunkova

    2007-01-01

    Full Text Available We report on the structure and optical properties of hydrogenated silicon thin films deposited by plasma - enhanced chemical vapor deposition (PECVD from silane diluted with hydrogen in a wide dilution range. The samples deposited with dilutions below 30 were detected as amorphous hydrogenated silicon (a-Si:H with crystalline grains of several nanometers in size which represent the medium-range order of a-Si:H. The optical characterization confirmed increasing ordering with the increasing dilution. The optical band gap was observed to be increasing function of the dilution.

  3. Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Liu, Jiwei; Li, Haiyang

    2016-03-01

    Exhaled nitric oxide (NO) is one of the most promising breath markers for respiratory diseases. Its profile for exhalation and the respiratory NO production sites can provide useful information for medical disease diagnosis and therapeutic procedures. However, the high-level moisture in exhaled gas always leads to the poor selectivity and sensitivity for ion spectrometric techniques. Herein, a method based on fast non-equilibrium dilution ion mobility spectrometry (NED-IMS) was firstly proposed to directly monitor the exhaled NO profile on line. The moisture interference was eliminated by turbulently diluting the original moisture to 21% of the original with the drift gas and dilution gas. Weak enhancement was observed for humid NO response and its limit of detection at 100% relative humidity was down to 0.58 ppb. The NO concentrations at multiple exhalation flow rates were measured, while its respiratory production sites were determined by using two-compartment model (2CM) and Högman and Meriläinen algorithm (HMA). Last but not the least, the NO production sites were analyzed hourly to tentatively investigate the daily physiological process of NO. The results demonstrated the capacity of NED-IMS in the real-time analysis of exhaled NO and its production sites for clinical diagnosis and assessment.

  4. The measurement of water vapor permeability of glove materials using dilute tritiated water

    International Nuclear Information System (INIS)

    Doughty, D.H.

    1982-01-01

    As fusion technology progresses, there will be an increasing need to handle tritium and tritiated compounds. Protective clothing, especially drybox gloves, must be an effective barrier to minimize worker exposure. The water vapor permeability of glove materials and finished glove constructions is a crucial property of drybox gloves and is not sufficiently well characterized. We have built an apparatus that measures water vapor permeability of elastomers using dilute tritiated water. The technique is more sensitive than other methods currently available and allows us to make measurements on materials and under conditions previously inaccessible. In particular, we present results on laminated drybox gloves for which data is not currently available. (orig.)

  5. Quantification of root associated nitrogen fixation in kallar grass as estimated by sup/15/nitrogen isotope dilution

    International Nuclear Information System (INIS)

    Malik, K.A.; Zafar, Y.

    1985-01-01

    Present investigations were made by using sup/15/N isotope dilution technique to quantitatively estimate BNF in Kallar grass when grown under controlled conditions in nutrient solution and inoculated with N sub/2/-fixing bacteria. Azospirillum brasilense and two isolates from the rhizosphere of kallar grass were used as inoculant. After harvest acetylen reduction of roots, total yield, total N and sup/15/ N analysis were made. Total-N in inoculated treatments was 2-3 times higher than in control and so were the fresh and dry weight yields. The estimates based on isotopic dilution indicated that 50-70 percent N in the plant was derived from BNF in case of inoculated treatment. The results based on N balance gave relatively lower values of 40-60 percent of total N derived from fixation. The data revealed that in Kallar grass a substantial amount of plant N is derived from BNF. (orig./A.B.)

  6. The issue of risk dilution in risk assessments

    International Nuclear Information System (INIS)

    Wilmot, R.; Robinson, P.

    2004-01-01

    This paper explores an issue that was first highlighted more than 20 years ago during an inquiry concerning the Sizeweli B nuclear power station in the UK. In the probabilistic safety assessment for this plant, the proponent had apparently reduced its estimates of risk by admitting to increased uncertainty about the timing of certain events. This situation is counter-intuitive, since an increase in uncertainty about the factors contributing to safety would be expected to lead to less confidence and hence to greater risk. This paradoxical situation was termed 'risk dilution' and it has been a topic of interest to reviewers of safety cases since. The recent international peer review of the Yucca Mountain performance assessments concluded that there was a potential for risk dilution in the assumptions and calculations presented. The next section describes how assumptions about the timing of events and other aspects of an assessment may lead to risk dilution, and this is followed by two examples based on recent performance assessments. The final section discusses how potential problems can be identified in safety cases, and the types of response that a regulator might adopt as a result. (authors)

  7. Isolation and structural characterization of sugarcane bagasse lignin after dilute phosphoric acid plus steam explosion pretreatment and its effect on cellulose hydrolysis

    Science.gov (United States)

    Jijiao Zeng; Zhaohui Tong; Letian Wang; J.Y. Zhu; Lonnie Ingram

    2014-01-01

    The structure of lignin after dilute phosphoric acid plus steam explosion pretreatment process of sugarcane bagasse in a pilot scale and the effect of the lignin extracted by ethanol on subsequent cellulose hydrolysis were investigated. The lignin structural changes caused by pretreatment were identified using advanced nondestructive techniques such as gel permeation...

  8. Primary system boron dilution analysis

    International Nuclear Information System (INIS)

    Crump, R.J.; Naretto, C.J.; Borgen, R.A.; Rockhold, H.C.

    1978-01-01

    The results are presented for an analysis conducted to determine the potential paths through which nonborated water or water with insufficient boron concentration might enter the LOFT primary coolant piping system or reactor vessel to cause dilution of the borated primary coolant water. No attempt was made in the course of this analysis to identify possible design modifications nor to suggest changes in administrative procedures or controls

  9. Test plan for tank 241-AN-104 dilution studies

    International Nuclear Information System (INIS)

    Herting, D.L.

    1998-01-01

    Tank 241-AN-104 (104-AN) has been identified as the one of the first tanks to be retrieved for low level waste pretreatment and immobilization. Retrieval of the tank waste will require dilution. Laboratory tests are needed to determine the amount and type of dilution required for safe retrieval and transfer of feed and to re-dissolve major soluble sodium salts while not precipitating out other salts. The proposed laboratory tests are described in this document. Tank 241-AN-104 is on the Hydrogen Watch List

  10. Magnetic properties of diluted magnetic semiconductors

    NARCIS (Netherlands)

    Jonge, de W.J.M.; Swagten, H.J.M.

    1991-01-01

    A review will be given of the magnetic characteristics of diluted magnetic semiconductors and the relation with the driving exchange mechanisms. II–VI as well as IV–VI compounds will be considered. The relevance of the long-range interaction and the role of the carrier concentration will be

  11. Study on nitrogen diluted propane-air premixed flames at elevated pressures and temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Tang Chenglong; Zheng Jianjun [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Huang Zuohua, E-mail: zhhuang@mail.xjtu.edu.c [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Wang Jinhua [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China)

    2010-02-15

    Using a high pressure constant volume combustion vessel, the propagation and morphology of spark-ignited outwardly expanding nitrogen diluted propane-air flames were imaged and recorded by schlieren photography and high-speed digital camera. The unstretched laminar burning velocities and Markstein lengths were subsequently determined over wide range of initial temperatures, initial pressures and nitrogen dilution ratios. Two recently developed mechanisms were used to predict the reference laminar burning velocity. The results show that the measured unstretched laminar burning velocities agree well with those in the literature and the computationally predicted results. The flame images show that the diffusional-thermal instability is promoted as the mixture becomes richer, and the hydrodynamic instability is increased with the increase of the initial pressure and it is decreased with the increase of dilution ratio. The normalized laminar burning velocities show a linear correlation with respect to the dilution ratio, indicating that the effect of nitrogen dilution is more obvious at higher pressures.

  12. Oxalate content of different drinkable dilutions of tea infusions after different brewing times.

    Science.gov (United States)

    Lotfi Yagin, Neda; Mahdavi, Reza; Nikniaz, Zeinab

    2012-01-01

    The aims of this study were to determine the effect of different brewing times and diluting on oxalate content of loose-packed black teas consumed in Tabriz, Iran. The oxalate content of black teas after brewing for 5, 10, 15, 30, 60 minutes was measured in triplicate by enzymatic assay. In order to attain the most acceptable dilution of tea infusions, tea samples which were brewed for 15, 30 and 60 minutes were diluted two (120 ml), three (80 ml) and four (60 ml) times respectively. There was a stepwise increase in oxalate concentrations associated with increased brewing times (Pbrewing times, respectively. There were significant differences between the mean oxalate content of different dilutions after brewing for 15, 30 and 60 minutes (Pbrewing times and different dilution was below the recommended levels. Therefore, it seems that consumption of black tea several times per day would not pose significant health risk in kidney stone patients and susceptible individuals.

  13. Dilution rate and microstructure of TIG arc Ni-Al powder surfacing layer

    Institute of Scientific and Technical Information of China (English)

    SHAN Jiguo; DONG Wei; TAN Wenda; ZHANG Di; PEN Jialie

    2007-01-01

    Surfacing beads are prepared by a direct current tungsten inert gas arc nickel-aluminum (Ni-Al) powder surfacing process. With the aim of controlling the dilution rate and obtaining surfacing beads rich in intermetallic compounds, the effects of surfacing parameters on geometric parameters, dilution rate, composition, and microstructure of the bead are investigated. An assistant cooler, which can potentially reduce the temperature of the base metal, is used in the surfacing process and its effect on dilution rate and microstructure is studied. The result indicates that with the surfacing parameter combination of low current and speed, the width and penetration of the bead decrease, reinforcement increases, and dilution rate drops markedly. With the reduc- tion of the parameter combination, the intergranular phase T-(Fe, Ni) is formed in the grain boundaries of Ni-Al interme- tallic matrix instead of the intergranular phase α-Fe, and large amount of intermetallics are obtained. With the use of an assistant cooler on a selected operation condition during the surfacing process, the reinforcement of the bead increases, penetration decreases, and dilution rate declines. The use of an assistant cooler helps obtain a surfacing bead composed of only intermetallics.

  14. Polymorphisms within the canine MLPH gene are associated with dilute coat color in dogs

    Directory of Open Access Journals (Sweden)

    Günzel-Apel Anne-Rose

    2005-06-01

    Full Text Available Abstract Background Pinschers and other dogs with coat color dilution show a characteristic pigmentation phenotype. The fur colors are a lighter shade, e.g. silvery grey (blue instead of black and a sandy color (Isabella fawn instead of red or brown. In some dogs the coat color dilution is sometimes accompanied by hair loss and recurrent skin inflammation, the so called color dilution alopecia (CDA or black hair follicular dysplasia (BHFD. In humans and mice a comparable pigmentation phenotype without any documented hair loss is caused by mutations within the melanophilin gene (MLPH. Results We sequenced the canine MLPH gene and performed a mutation analysis of the MLPH exons in 6 Doberman Pinschers and 5 German Pinschers. A total of 48 sequence variations was identified within and between the breeds. Three families of dogs showed co-segregation for at least one polymorphism in an MLPH exon and the dilute phenotype. No single polymorphism was identified in the coding sequences or at splice sites that is likely to be causative for the dilute phenotype of all dogs examined. In 18 German Pinschers a mutation in exon 7 (R199H was consistently associated with the dilute phenotype. However, as this mutation was present in homozygous state in four dogs of other breeds with wildtype pigmentation, it seems unlikely that this mutation is truly causative for coat color dilution. In Doberman Pinschers as well as in Large Munsterlanders with BHFD, a set of single nucleotide polymorphisms (SNPs around exon 2 was identified that show a highly significant association to the dilute phenotype. Conclusion This study provides evidence that coat color dilution is caused by one or more mutations within or near the MLPH gene in several dog breeds. The data on polymorphisms that are strongly associated with the dilute phenotype will allow the genetic testing of Pinschers to facilitate the breeding of dogs with defined coat colors and to select against Large

  15. Influence Of Dilution Factor For Activity Measurement Of 60CO

    International Nuclear Information System (INIS)

    Hermawan-Candra; Nazaroh; Ermi-Juita

    2003-01-01

    Influence of dilution factor for activity measurement of 60 Co has been studied. The aim of this research is to determine influence between activity measurement result of 60 Co before and after diluted. Measurement were done by using ionization chamber detectors system and gamma spectrometry system with NaI(TI) detector. Discrepancy within three ionization chambers measurements were 0.2% - 2.1% and NaI(Tl) were 3.5% - 6%. (author)

  16. Just add water: Accuracy of analysis of diluted human milk samples using mid-infrared spectroscopy.

    Science.gov (United States)

    Smith, R W; Adamkin, D H; Farris, A; Radmacher, P G

    2017-01-01

    To determine the maximum dilution of human milk (HM) that yields reliable results for protein, fat and lactose when analyzed by mid-infrared spectroscopy. De-identified samples of frozen HM were obtained. Milk was thawed and warmed (40°C) prior to analysis. Undiluted (native) HM was analyzed by mid-infrared spectroscopy for macronutrient composition: total protein (P), fat (F), carbohydrate (C); Energy (E) was calculated from the macronutrient results. Subsequent analyses were done with 1 : 2, 1 : 3, 1 : 5 and 1 : 10 dilutions of each sample with distilled water. Additional samples were sent to a certified lab for external validation. Quantitatively, F and P showed statistically significant but clinically non-critical differences in 1 : 2 and 1 : 3 dilutions. Differences at higher dilutions were statistically significant and deviated from native values enough to render those dilutions unreliable. External validation studies also showed statistically significant but clinically unimportant differences at 1 : 2 and 1 : 3 dilutions. The Calais Human Milk Analyzer can be used with HM samples diluted 1 : 2 and 1 : 3 and return results within 5% of values from undiluted HM. At a 1 : 5 or 1 : 10 dilution, however, results vary as much as 10%, especially with P and F. At the 1 : 2 and 1 : 3 dilutions these differences appear to be insignificant in the context of nutritional management. However, the accuracy and reliability of the 1 : 5 and 1 : 10 dilutions are questionable.

  17. Effects of diluting medium and holding time on sperm motility analysis by CASA in ram.

    Science.gov (United States)

    Mostafapor, Somayeh; Farrokhi Ardebili, Farhad

    2014-01-01

    The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA). The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP), phosphate-buffered saline (PBS) containing 1% bovine serum albumin (BSA) and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP), straightness (STR), linearity (LIN), amplitude of lateral head displacement (ALH), and beat cross frequency (BCF). In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.

  18. Effects of diluting medium and holding time on sperm motility analysis by CASA in ram

    Directory of Open Access Journals (Sweden)

    Somayeh Mostafapor

    2014-06-01

    Full Text Available The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA. The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP, phosphate-buffered saline (PBS containing 1% bovine serum albumin (BSA and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL, straight line velocity (VSL, average path velocity (VAP, straightness (STR, linearity (LIN, amplitude of lateral head displacement (ALH, and beat cross frequency (BCF. In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.

  19. Thermodynamics of a dilute XX chain in a field

    Energy Technology Data Exchange (ETDEWEB)

    Timonin, P. N., E-mail: pntim@live.ru [Southern Federal University, Physics Research Institute (Russian Federation)

    2016-06-15

    Gapless phases in ground states of low-dimensional quantum spin systems are rather ubiquitous. Their peculiarity is a remarkable sensitivity to external perturbations due to permanent criticality of such phases manifested by a slow (power-low) decay of pair correlations and the divergence of the corresponding susceptibility. A strong influence of various defects on the properties of the system in such a phase can then be expected. Here, we consider the influence of vacancies on the thermodynamics of the simplest quantum model with a gapless phase, the isotropic spin-1/2 XX chain. The existence of the exact solution of this model gives a unique opportunity to describe in detail the dramatic effect of dilution on the gapless phase—the appearance of an infinite series of quantum phase transitions resulting from level crossing under the variation of a longitudinal magnetic field. We calculate the jumps in the field dependences of the ground-state longitudinal magnetization, susceptibility, entropy, and specific heat appearing at these transitions and show that they result in a highly nonlinear temperature dependence of these parameters at low T. Also, the effect of enhancement of the magnetization and longitudinal correlations in the dilute chain is established. The changes of the pair spin correlators under dilution are also analyzed. The universality of the mechanism of the quantum transition generation suggests that similar effects of dilution can also be expected in gapless phases of other low-dimensional quantum spin systems.

  20. Axion cosmology, lattice QCD and the dilute instanton gas

    International Nuclear Information System (INIS)

    Borsanyi, S.; Fodor, Z.; Mages, S.W.; Nogradi, D.; Szabo, K.K.

    2015-08-01

    Axions are one of the most attractive dark matter candidates. The evolution of their number density in the early universe can be determined by calculating the topological susceptibility χ(T) of QCD as a function of the temperature. Lattice QCD provides an ab initio technique to carry out such a calculation. A full result needs two ingredients: physical quark masses and a controlled continuum extrapolation from non-vanishing to zero lattice spacings. We determine χ(T) in the quenched framework (infinitely large quark masses) and extrapolate its values to the continuum limit. The results are compared with the prediction of the dilute instanton gas approximation (DIGA). A nice agreement is found for the temperature dependence, whereas the overall normalization of the DIGA result still differs from the non-perturbative continuum extrapolated lattice results by a factor of order ten. We discuss the consequences of our findings for the prediction of the amount of axion dark matter.

  1. Approaches of aroma extraction dilution analysis (AEDA) for headspace solid phase microextraction and gas chromatography-olfactometry (HS-SPME-GC-O): Altering sample amount, diluting the sample or adjusting split ratio?

    Science.gov (United States)

    Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming

    2015-11-15

    Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.

  2. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions......, necessary precautions for the application of these experimental techniques are emphasized. Special attention has been carried out to elucidate the consequence of a choice of indicators having a large distribution volume in the tissues....

  3. Dilution and volatilization of groundwater contaminant discharges in streams

    DEFF Research Database (Denmark)

    Aisopou, Angeliki; Bjerg, Poul Løgstrup; Sonne, Anne Thobo

    2015-01-01

    measurement. The solution was successfully applied to published field data obtained in a large and a small Danish stream and provided valuable information on the risk posed by the groundwater contaminant plumes. The results provided by the dilution and volatilization model are very different to those obtained......An analytical solution to describe dilution and volatilization of a continuous groundwater contaminant plume into streams is developed for risk assessment. The location of groundwater plume discharge into the stream (discharge through the side versus bottom of the stream) and different...

  4. How Consumers’ Styles of Thinking Can Control Brand Dilution

    Directory of Open Access Journals (Sweden)

    Monga Alokparna Basu

    2018-05-01

    Full Text Available Understanding consumers’ ways of thinking can help identify strategies to limit brand damage and elicit more favorable reactions from disapproving consumers. Analytic thinkers’ beliefs about a brand are diluted when they see negative information; those of holistic thinkers remain unaffected. While both analytic and holistic thinkers blame the brand equally for quality and manufacturing problems, holistic thinkers are more likely to blame contextual factors outside of the brand than analytic thinkers. This ability of holistic thinkers to focus on the outside context is the reason why their brand beliefs are not diluted.

  5. ELISA technique standardization for strongyloidiasis diagnosis

    International Nuclear Information System (INIS)

    Huapaya, P.; Espinoza, I.; Huiza, A.; Universidad Nacional Mayor de San Marcos, Lima; Sevilla, C.

    2002-01-01

    To standardize ELISA technique for human Strongyloides stercoralis infection diagnosis a crude antigen was prepared using filariform larvae obtained from positive stool samples cultured with charcoal. Harvested larvae were crushed by sonication and washed by centrifugation in order to obtain protein extracts to be used as antigen. Final protein concentration was 600 μg/mL. Several kinds of ELISA plates were tested and antigen concentration, sera dilution, conjugate dilution and cut off were determined to identify infection. Sera from patients with both hyper-infection syndrome and intestinal infection demonstrated by parasitological examination were positive controls and sera from people living in non-endemic areas with no infection demonstrated by parasitological examination were negative controls. Best values were 5 μg/mL for antigen, 1/64 for sera, 1/1000 for conjugate; optical density values for positive samples were 1,2746 (1,1065 - 1,4206, DS = 0,3284) and for negative samples 0,4457 (0,3324 - 0,5538, DS = 0,2230). Twenty sera samples from positive subjects and one hundred from negative subjects were examined, obtaining 90% sensitivity and 88% specificity. The results show this technique could be useful as strongyloidiasis screening test in population studies

  6. Non-Markovian near-infrared Q branch of HCl diluted in liquid Ar.

    Science.gov (United States)

    Padilla, Antonio; Pérez, Justo

    2013-08-28

    By using a non-Markovian spectral theory based in the Kubo cumulant expansion technique, we have qualitatively studied the infrared Q branch observed in the fundamental absorption band of HCl diluted in liquid Ar. The statistical parameters of the anisotropic interaction present in this spectral theory were calculated by means of molecular dynamics techniques, and found that the values of the anisotropic correlation times are significantly greater (by a factor of two) than those previously obtained by fitting procedures or microscopic cell models. This fact is decisive for the observation in the theoretical spectral band of a central Q resonance which is absent in the abundant previous researches carried out with the usual theories based in Kubo cumulant expansion techniques. Although the theory used in this work only allows a qualitative study of the Q branch, we can employ it to study the unknown characteristics of the Q resonance which are difficult to obtain with the quantum simulation techniques recently developed. For example, in this study we have found that the Q branch is basically a non-Markovian (or memory) effect produced by the spectral line interferences, where the PR interferential profile basically determines the Q branch spectral shape. Furthermore, we have found that the Q resonance is principally generated by the first rotational states of the first two vibrational levels, those more affected by the action of the dissolvent.

  7. The Effect of Dilution on Microsegregation in AWS ER NiCrMo-14 Alloy Welding Claddings

    Science.gov (United States)

    Miná, Émerson Mendonça; da Silva, Yuri Cruz; Dille, Jean; Silva, Cleiton Carvalho

    2016-12-01

    Dilution and microsegregation are phenomena inherent to claddings, which, in turn, directly affect their main properties. This study evaluated microsegregation in the fusion zone with different dilution levels. The overlays were welded by the TIG cold wire feed process. Dilution was calculated from the geometric characteristics of the claddings and from the conservation of mass equation using chemical composition measurements. Microsegregation was calculated using energy dispersive X-ray spectroscopy measurements of the dendrites and the chemical composition of the fusion zone. The dilution of the claddings was increased by reducing the wire feed rate. Fe showed potential to be incorporated into the solid phase ( k > 1), and this increased with the increase of dilution. Mo, in turn, was segregated into the liquid phase ( k < 1) and also increased with the increase of dilution. However, Cr and W showed a slight decrease in their partition coefficients ( k) with the increase of dilution.

  8. Studies on the dilution behaviour of effluent discharged into the CCW channel at KGS

    International Nuclear Information System (INIS)

    Sivasubramanian, K.; Srinivasan, S.; Ponraju, D.; Meenakshisundaram, V.; Munusamy, N.

    2003-01-01

    The dilution behaviour of the liquid effluent discharged into condenser cooling water channel of Kaiga Power Plant has been studied using salt addition and dye addition methods. Dilution factors determined experimentally showed that the discharged liquid effluent gets thoroughly mixed with stream of water at the weir and further diluted in the down stream. This paper describes both salt and dye addition methods for determining the dilution factor. The velocity of the stream at various locations were measured and compared with reported values. The selection of representative sampling point for routine analysis of water was identified from this experiment. (author)

  9. Percolation of polyatomic species on site diluted lattices

    International Nuclear Information System (INIS)

    Cornette, V.; Ramirez-Pastor, A.J.; Nieto, F.

    2006-01-01

    In this Letter, the percolation of (a) linear segments of size k and (b) k-mers (particles occupying k adjacent sites) of different structures and forms deposited on a diluted square lattice have been studied. The diluted lattice is built by randomly selecting a fraction of sites which are considered forbidden for deposition. The analysis of the obtained results is made in the framework of the finite size scaling theory. The characteristic parameters of the percolation problem are dependent not only on the form and structure of the k-mers but also on the properties of the lattice where they are deposited. A phase diagram separating a percolating from a non-percolating region is determined and discussed

  10. Dilute brimonidine to improve patient comfort and subconjunctival hemorrhage after LASIK.

    Science.gov (United States)

    Pasquali, Theodore A; Aufderheide, Adam; Brinton, Jason P; Avila, Michele R; Stahl, Erin D; Durrie, Daniel S

    2013-07-01

    To investigate whether dilute brimonidine (0.025%) reduces patient discomfort, subconjunctival hemorrhage, and injection after LASIK without a significant increase in the rate of flap complications or surgical enhancements. This randomized, double-blind, prospective study enrolled 180 patients (360 eyes) in a contralateral eye comparison of topical dilute brimonidine, naphazoline/pheniramine, or Systane Ultra (Alcon Laboratories, Inc., Fort Worth, TX) administered shortly before LASIK for any indication. Patients were evaluated for subconjunctival hemorrhage, injection, and flap dislocation 1 hour and 1 day postoperatively. Patient questionnaires measuring patient comfort and ocular symptoms were administered at these same follow-up visits. Patients were examined for 3 months to determine similar outcomes for standard indices of safety, predictability, efficacy, and enhancement rates. Scores of patient discomfort, subconjunctival hemorrhage, and injection were significantly lower in eyes treated with dilute brimonidine at the 1 hour and 1 day postoperative examinations. Refloats for mild-flap edge wrinkling were required in 3 brimonidine eyes (2.5%), 1 naphazoline/pheniramine eye (0.8%), and no control eyes, but this difference did not reach statistical significance (P = .18). There was no significant difference between eyes at 3 months in terms of visual acuity, refractive error, corrected distance visual acuity, or rate of enhancement. Use of dilute brimonidine before LASIK reduces subconjunctival hemorrhage and injection and improves patient comfort after surgery. Flap edge wrinkling requiring refloat may still be a complication with dilute brimonidine. Copyright 2013, SLACK Incorporated.

  11. Evaluation of the Antibacterial and Antifungal Properties of Phragmanthera capitata (Sprengel Balle (Loranthaceae, a Mistletoe Growing on Rubber Tree, Using the Dilution Techniques

    Directory of Open Access Journals (Sweden)

    Franklin Uangbaoje Ohikhena

    2017-01-01

    Full Text Available The alarming increase in multidrug resistance of pathogenic microorganisms to conventional drugs in recent years has prompted the search for new leads in alternative remedies in natural products. Hence, this study was aimed at evaluating the antimicrobial properties of Phragmanthera capitata, a parasitic mistletoe growing on rubber trees. The in vitro antimicrobial activities of the acetone, methanol, ethanol, and aqueous extracts were investigated using five gram-negative and five gram-positive bacteria and four fungi. A 96-well resazurin broth and agar dilution techniques were used for the determination of the Minimum Inhibitory and Bactericidal Concentrations. The antibacterial activity of the organic extracts had comparative effects on all the bacteria with a MIC of 1.25 to 5 mg/mL and MBC of 2.5 to 10 mg/mL. However, the acetone extract showed higher bactericidal effect while the aqueous extract was not active. The organic solvent extracts also showed antifungal activities on two of the fungi with a MIC of 1.25 mg/mL to 10 mg/mL. However, the aqueous extract had the highest activity inhibiting all the fungi with a MIC of ≤0.3125 to 1.25 mg/mL. The study supports the ethnomedicinal claims of P. capitata as a remedy for the diseases/infections caused by these organisms.

  12. First-principle natural band alignment of GaN / dilute-As GaNAs alloy

    Directory of Open Access Journals (Sweden)

    Chee-Keong Tan

    2015-01-01

    Full Text Available Density functional theory (DFT calculations with the local density approximation (LDA functional are employed to investigate the band alignment of dilute-As GaNAs alloys with respect to the GaN alloy. Conduction and valence band positions of dilute-As GaNAs alloy with respect to the GaN alloy on an absolute energy scale are determined from the combination of bulk and surface DFT calculations. The resulting GaN / GaNAs conduction to valence band offset ratio is found as approximately 5:95. Our theoretical finding is in good agreement with experimental observation, indicating the upward movements of valence band at low-As content dilute-As GaNAs are mainly responsible for the drastic reduction of the GaN energy band gap. In addition, type-I band alignment of GaN / GaNAs is suggested as a reasonable approach for future device implementation with dilute-As GaNAs quantum well, and possible type-II quantum well active region can be formed by using InGaN / dilute-As GaNAs heterostructure.

  13. A radioactive tracer dilution method to determine the mass of molten salt

    International Nuclear Information System (INIS)

    Lei Cao; Jarrell, Josh; Hardtmayer, D.E.; White, Susan; Herminghuysen, Kevin; Kauffman, Andrew; Sanders, Jeff; Li, Shelly

    2017-01-01

    A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22 Na as a tracer was validated at bench scale. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined. (author)

  14. Separation of glycols from dilute aqueous solutions via complexation with boronic acids

    Energy Technology Data Exchange (ETDEWEB)

    Randel, L.A.; King, C.J.

    1991-07-01

    This work examines methods of separating low molecular weight glycols from dilute aqueous solution. Extraction into conventional solvents is generally not economical, since, in the literature reviewed, distribution ratios for the two- to four-carbon glycols are all less than one. Distribution ratios can be increased, however, by incorporating into the organic phase an extracting agent that will complex with the solute of interest. The extracting agent investigated in this work is 3-nitrophenylboronic acid (NPBA). NPBA, a boric acid derivative, reversibly complexes with many glycols. The literature on complexation of borate and related compounds with glycols, including mechanistic data, measurement techniques, and applications to separation processes, provides information valuable for designing experiments with NPBA and is reviewed herein. 88 refs., 15 figs., 24 tabs.

  15. Mid-dilution hemodiafiltration: a comparison with pre- and postdilution modes using the same polyphenylene membrane.

    Science.gov (United States)

    Maduell, Francisco; Arias, Marta; Vera, Manel; Fontseré, Néstor; Blasco, Miquel; Barros, Xoana; Garro, Julia; Elena, Montserrat; Bergadá, Eduardo; Cases, Aleix; Bedini, Jose Luis; Campistol, Josep M

    2009-01-01

    As a change from Diapes to polyphenylene membrane in the mid-dilution filter has recently been developed, the aim of this study was to compare mid-dilution using this new dialyzer versus pre- and postdilution. The prospective study included 20 patients who underwent 4 hemodiafiltration (HDF) sessions: 1.7 m(2) polyphenylene and predilution infusion flow (Qi) 200 ml/min, 1.7 m(2) and postdilution Qi 100 ml/min, 1.9 and 2.2 m(2) mid-dilution both with Qi 200 ml/ min. The urea and creatinine reduction ratios were slightly higher in postdilution. The beta(2)-microglobulin (85.8%), myoglobin (73.6%), prolactin (67.8%) and retinol-binding protein (29.2%) reduction ratios with 1.9 m(2) mid-dilution, which was similar to 2.2 m(2) mid-dilution, were significantly higher than with the post- and predilution modes. Mid-dilution appears to be a good HDF alternative that allows a better removal of larger molecules than postdilution and, mainly, predilution. Mid-dilution using 1.9 or 2.2 m(2) dialyzers, at the same convective volume, showed a similar removal. Copyright 2009 S. Karger AG, Basel.

  16. Experimental substantiation of separation techniques of lead and uranium microamounts using isotopic dilution method as control method

    International Nuclear Information System (INIS)

    Agapova, A.A.; Shcherbinina, N.K.

    1983-01-01

    Methods,ensuring at low levels of contamination a high degree of lead and uranium microamount separation from solutions of geological samples, have been selected and subjected to the detailed testing. The method of isotope dilution, , combining high accuracy and sensitivity of determinations, is used as the main control methods, is used as the main control method. Using the method, processe es of uranium extpaction are traced, special attention is paid to the detailed description of lead extraction at all the stages of the methods selected. Opera ations of ion exchange for lead and uranium in microcolumns with the Bio-Rad r sin are considered, as well as operations of lead electrolytic separation. The chemical procedures suggested permit to solve one of the main methodical tasks f sample preparation, containing microgram amounts of lead and uranium, for high h-prcision measurement of their isotope composition using mass-spectrometric method

  17. Universal water-dilutable inhibited protective lubricants

    International Nuclear Information System (INIS)

    Mamtseva, M.V.; Kardash, N.V.; Latynina, M.B.

    1993-01-01

    In the interest of environmental protection, improvement of working conditions, and reduced fire hazard in production operations, water-based protective lubricants are now available in a wide assortment, and the production volume has increased greatly. The term water-dilutable inhibited protective lubricants (WDIPL) means water-soluble, water-emulsifiable, or water-dispersible products with the dual function of reducing friction and wear and protecting metal surfaces against corrosion for specified periods of time. According to the standard Unified System of Protection Against Corrosion and Aging (COST 9.103-78), WDIPLs are classed as products for the temporary corrosion protection of metals and end-items. In the general class of WDIPLs one can identify water-dilutable combination corrosion inhibitors, film-forming inhibited petroleum compositions (FIPC-d), detergent-preservative fluids, operational-preservative lubricating-cooling process compounds (ICPC), and, finally, universal multifunctional products. Combined corrosion inhibitors may consist of water-soluble organic and inorganic compounds; water/oil and oil-soluble surfactants - corrosion inhibitors of the chemisorption type or donor and/or acceptor types; shielding inhibitors of the adsorption type; and fast-acting water-displacing components. 23 refs

  18. Prototype Repository. Tracer dilution tests during operation phase, test campaign 3

    Energy Technology Data Exchange (ETDEWEB)

    Harrstroem, Johan; Andersson, Peter (Geosigma AB (Sweden))

    2010-05-15

    The Prototype Repository project is focused on testing and demonstrating the function of the SKB deep repository system. The third tracer dilution campaign during the Prototype Repository operation period was performed in January 2010. The purpose was to estimate the groundwater flows and hydraulic gradients in the boreholes vicinity and will function as a reference for comparison with results from modeling and prior assumptions. The test campaign consisted of tracer dilution tests in 13 different borehole sections. Each test consisted of approximately 15-55 min tracer injection time and about 1-3 days dilution test time depending on the transmissivity of the test section. The data interpretation also included estimates of the local hydraulic gradients in the vicinity of the borehole sections

  19. Solubilization of tea seed oil in a food-grade water-dilutable microemulsion.

    Directory of Open Access Journals (Sweden)

    Lingli Deng

    Full Text Available Food-grade microemulsions containing oleic acid, ethanol, Tween 20, and water were formulated as a carrier system for tea seed oil (Camellia oleifera Abel.. The effect of ethanol on the phase behavior of the microemulsion system was clearly reflected in pseudo-ternary diagrams. The solubilization capacity and solubilization efficiency of tea seed oil dispersions were measured along the dilution line at a 70/30 surfactant/oil mass ratio with Tween 20 as the surfactant and oleic acid and ethanol (1:3, w/w as the oil phase. The dispersed phase of the microemulsion (1.5% weight ratio of tea seed oil to the total amount of oil, surfactant, and tea seed oil could be fully diluted with water without phase separation. Differential scanning calorimetry and viscosity measurements indicated that both the carrier and solubilized systems underwent a similar microstructure transition upon dilution. The dispersion phases gradually inverted from the water-in-oil phase ( 45% water along the dilution line.

  20. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  1. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  2. Fast and accurate calculation of dilute quantum gas using Uehling–Uhlenbeck model equation

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Ryosuke, E-mail: ryosuke.yano@tokiorisk.co.jp

    2017-02-01

    The Uehling–Uhlenbeck (U–U) model equation is studied for the fast and accurate calculation of a dilute quantum gas. In particular, the direct simulation Monte Carlo (DSMC) method is used to solve the U–U model equation. DSMC analysis based on the U–U model equation is expected to enable the thermalization to be accurately obtained using a small number of sample particles and the dilute quantum gas dynamics to be calculated in a practical time. Finally, the applicability of DSMC analysis based on the U–U model equation to the fast and accurate calculation of a dilute quantum gas is confirmed by calculating the viscosity coefficient of a Bose gas on the basis of the Green–Kubo expression and the shock layer of a dilute Bose gas around a cylinder.

  3. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    be attributed to the reliability of the measured distances which fall off quickly with each shell. Therefore, in ... field and electrical field gradients due to impurities in vanadium [13]. The effective .... Expanding ∆φ(| Rn' |) in power series of u(R0 n), one gets ... The results of each dilute alloy system are presented separately and ...

  4. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    We present here a systematic investigation of the atomic displacements in bcc transition metal (TM) dilute alloys. We have calculated the atomic displacements in bcc (V, Cr, Fe, Nb, Mo, Ta and W) transition metals (TMs) due to 3d, 4d and 5d TMs at the substitutional site using the Kanzaki lattice static method. Wills and ...

  5. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Simplified Method for Groundwater Treatment Using Dilution and Ceramic Filter

    Science.gov (United States)

    Musa, S.; Ariff, N. A.; Kadir, M. N. Abdul; Denan, F.

    2016-07-01

    Groundwater is one of the natural resources that is not susceptible to pollutants. However, increasing activities of municipal, industrial, agricultural or extreme land use activities have resulted in groundwater contamination as occured at the Research Centre for Soft Soil Malaysia (RECESS), Universiti Tun Hussein Onn Malaysia (UTHM). Thus, aims of this study is to treat groundwater by using rainwater and simple ceramic filter as a treatment agent. The treatment uses rain water dilution, ceramic filters and combined method of dilute and filtering as an alternate treatment which are simple and more practical compared to modern or chemical methods. The water went through dilution treatment processes able to get rid of 57% reduction compared to initial condition. Meanwhile, the water that passes through the filtering process successfully get rid of as much as 86% groundwater parameters where only chloride does not pass the standard. Favorable results for the combination methods of dilution and filtration methods that can succesfully eliminate 100% parameters that donot pass the standards of the Ministry of Health and the Interim National Drinking Water Quality Standard such as those found in groundwater in RECESS, UTHM especially sulfate and chloride. As a result, it allows the raw water that will use clean drinking water and safe. It also proves that the method used in this study is very effective in improving the quality of groundwater.

  7. Risk Assessment of New Chemical Substances. Dilution of Effluents in The Netherlands

    NARCIS (Netherlands)

    de Greef J; de Nijs ACM

    1990-01-01

    A detailed study has been undertaken on the dilution of effluent from waste water treatment plants in The Netherlands. Using a 2-dimensional dispersion model and data from the Central Bureau of Statistics, a general overview of the dilution of effluent in receiving surface waters has been compiled

  8. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    Science.gov (United States)

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material

    International Nuclear Information System (INIS)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-01-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound esposure time. Due to the complex matrix of this fly ash material, a two-steps purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs

  10. Synthesis of nano-sized amorphous boron powders through active dilution self-propagating high-temperature synthesis method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jilin [The State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Gu, Yunle [School of Material Science and Engineering, Wuhan Institute of Technology, Wuhan 430073 (China); Li, Zili [The State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Wang, Weimin, E-mail: wangwm@hotmail.com [The State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Fu, Zhengyi [The State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China)

    2013-06-01

    Graphical abstract: Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis (SHS) method. The effects of endothermic reaction rate, the possible chemical reaction mechanism and active dilution model for synthesis of the product were also discussed. Highlights: ► Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis method. ► The morphology, particle size and purity of the samples could be effectively controlled via changing the endothermic rate. ► The diluter KBH{sub 4} played an important role in active dilution synthesis of amorphous nano-sized boron powders. ► The active dilution method could be further popularized and become a common approach to prepare various inorganic materials. - Abstract: Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis (SHS) method at temperatures ranging from 700 °C to 850 °C in a SHS furnace using Mg, B{sub 2}O{sub 3} and KBH{sub 4} as raw materials. Samples were characterized by X-ray powder diffraction (XRD), Laser particle size analyzer, Fourier transform infrared spectra (FTIR), X-ray energy dispersive spectroscopy (EDX), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and high-resolution transmission TEM (HRTEM). The boron powders demonstrated an average particle size of 50 nm with a purity of 95.64 wt.%. The diluter KBH{sub 4} played an important role in the active dilution synthesis of amorphous nano-sized boron powders. The effects of endothermic reaction rate, the possible chemical reaction mechanism and active dilution model for synthesis of the product were also discussed.

  11. Synthesis of nano-sized amorphous boron powders through active dilution self-propagating high-temperature synthesis method

    International Nuclear Information System (INIS)

    Wang, Jilin; Gu, Yunle; Li, Zili; Wang, Weimin; Fu, Zhengyi

    2013-01-01

    Graphical abstract: Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis (SHS) method. The effects of endothermic reaction rate, the possible chemical reaction mechanism and active dilution model for synthesis of the product were also discussed. Highlights: ► Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis method. ► The morphology, particle size and purity of the samples could be effectively controlled via changing the endothermic rate. ► The diluter KBH 4 played an important role in active dilution synthesis of amorphous nano-sized boron powders. ► The active dilution method could be further popularized and become a common approach to prepare various inorganic materials. - Abstract: Nano-sized amorphous boron powders were synthesized by active dilution self-propagating high-temperature synthesis (SHS) method at temperatures ranging from 700 °C to 850 °C in a SHS furnace using Mg, B 2 O 3 and KBH 4 as raw materials. Samples were characterized by X-ray powder diffraction (XRD), Laser particle size analyzer, Fourier transform infrared spectra (FTIR), X-ray energy dispersive spectroscopy (EDX), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and high-resolution transmission TEM (HRTEM). The boron powders demonstrated an average particle size of 50 nm with a purity of 95.64 wt.%. The diluter KBH 4 played an important role in the active dilution synthesis of amorphous nano-sized boron powders. The effects of endothermic reaction rate, the possible chemical reaction mechanism and active dilution model for synthesis of the product were also discussed

  12. Buffer erosion in dilute groundwater

    International Nuclear Information System (INIS)

    Schatz, T.; Kanerva, N.; Martikainen, J.; Sane, P.; Olin, M.; Seppaelae, A.; Koskinen, K.

    2013-08-01

    One scenario of interest for repository safety assessment involves the loss of bentonite buffer material in contact with dilute groundwater flowing through a transmissive fracture interface. In order to examine the extrusion/erosion behavior of bentonite buffer material under such circumstances, a series of experiments were performed in a flow-through, 1 mm aperture, artificial fracture system. These experiments covered a range of solution chemistry (salt concentration and composition), material composition (sodium montmorillonite and admixtures with calcium montmorillonite), and flow velocity conditions. No erosion was observed for sodium montmorillonite against solution compositions from 0.5 g/L to 10 g/L NaCl. No erosion was observed for 50/50 calcium/sodium montmorillonite against 0.5 g/L NaCl. Erosion was observed for both sodium montmorillonite and 50/50 calcium/sodium montmorillonite against solution compositions ≤ 0.25 g/L NaCl. The calculated erosion rates for the tests with the highest levels of measured erosion, i.e., the tests run under the most dilute conditions (ionic strength (IS) < ∼1 mM), were well-correlated to flow velocity, whereas the calculated erosion rates for the tests with lower levels of measured erosion, i.e., the tests run under somewhat less dilute conditions (∼1 mM < IS < ∼4 mM), were not similarly correlated indicating that material and solution composition can significantly affect erosion rates. In every experiment, both erosive and non-erosive, emplaced buffer material extruded into the fracture and was observed to be impermeable to water flowing in the fracture effectively forming an extended diffusive barrier around the intersecting fracture/buffer interface. Additionally, a model which was developed previously to predict the rate of erosion of bentonite buffer material in low ionic strength water in rock fracture environments was applied to three different cases: sodium montmorillonite expansion in a vertical tube, a

  13. What infusion flow should be used for mid-dilution hemodiafiltration?

    Science.gov (United States)

    Maduell, Francisco; Arias, Marta; Fontseré, Néstor; Vera, Manel; Masso, Elisabeth; Garro, Julia; Barros, Xoana; Martina, Maria N; Elena, Montserrat; Bergadá, Eduardo; Cases, Aleix; Bedini, Jose Luis; Campistol, Josep M

    2010-01-01

    There is still no consensus on the optimal infusion flow (Qi) in mid-dilution hemodiafiltration. The aim of this study was to compare mid-dilution with varying Qi. Prospective study in 25 patients who underwent seven hemodialysis sessions with a Qi of 0, 50, 100, 150, 200, 250 and 300 ml/min. All sessions were well tolerated except Qi 300 ml/min. No significant differences in urea, creatinine, alpha(1)-microglobulin or alpha(1)-acid glycoprotein reduction ratios were observed. beta(2)-Microglobulin, myoglobin and prolactin reduction ratios were higher with Qi 150, 200, 250 and 300 ml/min in comparison with Qi of 0, 50 and 100 ml/min. There were no differences in the removal of small or larger molecules when Qi was 150 ml/min or higher. Optimal Qi in mid-dilution appears to be in the range of 150-250 ml/min since good clinical outcomes, similar efficiency and no technical complications up to a Qi of 250 ml/min were observed.

  14. Effect of solute segregation on thermal creep in dilute nanocyrstalline Cu alloys

    International Nuclear Information System (INIS)

    Schäfer, Jonathan; Ashkenazy, Yinon; Albe, Karsten; Averback, Robert S

    2012-01-01

    Highlights: ► Segregating solutes lower the grain boundary free volume in nanocrystalline Cu. ► Lower free volume leads to reduced atomic mobility and higher creep resistance. ► Increase in creep resistance scales with atomic size of segregating solutes. ► Atomic processes in boundaries are similar to the ones in amorphous material. - Abstract: The effect of solute segregation on thermal creep in dilute nanocrystalline alloys (Cu–Nb, Cu–Fe, Cu–Zr) was studied at elevated temperatures using molecular dynamics simulations. A combined Monte-Carlo and molecular dynamics simulation technique was first used to equilibrate the distribution of segregating solutes. Then the creep rates of the diluted Cu samples were measured as functions of temperature, composition, load and accumulated strain. In Cu–Nb samples, the creep rates were observed to increase initially with strain, but then saturate at a value close to that obtained for alloys prepared by randomly locating the solute in the grain boundaries. This behavior is attributed to an increase in grain boundary volume and energy with added chemical disorder. At high temperatures, the apparent activation energy for creep was anomalously high, 3 eV, but only 0.3 eV at lower temperatures. This temperature dependence is found to correlate with atomic mobilities in bulk Cu–Nb glasses. Calculations of creep in nanocrystalline Cu alloys containing other solutes, Fe and Zr, show that the suppression of creep rate scales with their atomic volumes when dissolved in Cu.

  15. Techniques for the generation and monitoring of vapors

    International Nuclear Information System (INIS)

    Nelson, G.O.

    1981-01-01

    Controlled test atmospheres can be produced using a variety of techniques. Gases are usually generated by using flow dilution methods while vapors are produced by using solvent injection and vaporization, saturation, permeation and diffusion techniques. The resulting gas mixtures can be monitored and measured using flame ionization, photoionization, electrochemical and infrared analytical systems. An ideal system for the production of controlled test atmospheres would not only be able to generate controlled test atmospheres, but also monitor all pertinent environmental parameters, such as temperature, humidity, and air flow

  16. Dilute nitride InNP quantum dots: Growth and photoluminescence mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kuang, Y. J. [Department of Physics, University of California, San Diego, La Jolla, California 92093 (United States); Takabayashi, K.; Kamiya, I. [Quantum Interface Laboratory, Toyota Technological Institute, Nagoya 468-8511 (Japan); Sukrittanon, S. [Material Science and Engineering Program, University of California, San Diego, La Jolla, California 92093 (United States); Pan, J. L.; Tu, C. W. [Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, California 92093 (United States)

    2014-10-27

    Self-assembled dilute nitride InNP quantum dots (QDs) in GaP matrix grown under the Stranski-Krastanov mode by gas-source molecular beam epitaxy are studied. The N-related localized states inside the InNP QDs provide a spatially direct recombination channel, in contrast to the spatially indirect channel through the strained In(N)P QDs/GaP interface states. The N incorporation into InP QDs therefore causes a blueshift and double-peak features in photoluminescence, which are not observed in other dilute nitride materials.

  17. Determination of the maximum inhibitory dilution of cetylpyridinium chloride-based mouthwashes against staphylococcus aureus: an in vitro study

    Directory of Open Access Journals (Sweden)

    Evandro Watanabe

    2008-08-01

    Full Text Available The aim of this in vitro study was to determine the maximum inhibitory dilution (MID of four cetylpyridinium chloride (CPC-based mouthwashes: CPC+Propolis, CPC+Malva, CPC+Eucaliptol+Juá+Romã+Propolis (Natural Honey® and CPC (Cepacol®, against 28 Staphylococcus aureus field strains, using the agar dilution method. Decimal dilutions ranging from 1/10 to 1/655,360 were prepared and added to Mueller Hinton Agar. Strains were inoculated using Steers multipoint inoculator. The inocula were seeded onto the surface of the culture medium in Petri dishes containing different dilutions of the mouthwashes. The dishes were incubated at 37ºC for 24 h. For readings, the MID was considered as the maximum dilution of mouthwash still capable of inhibiting microbial growth. The obtained data showed that CPC+Propolis had antimicrobial activity against 27 strains at 1/320 dilution and against all 28 strains at 1/160 dilution, CPC+Malva inhibited the growth of all 28 strains at 1/320 dilution, CPC+Eucaliptol+Juá+Romã+Propolis inhibited the growth of 2 strains at 1/640 dilution and all 28 strains at 1/320 dilution, and Cepacol® showed antimicrobial activity against 3 strains at 1/320 dilution and against all 28 strains at 1/160 dilution. Data were submitted to Kruskal-Wallis test, showing that the MID of Cepacol® was lower than that determined for the other products (p<0.05. In conclusion, CPC-mouthwashes showed antimicrobial activity against S. aureus and the addition of other substances to CPC improved its antimicrobial effect.

  18. GRAIN-BOUNDARY PRECIPITATION UNDER IRRADIATION IN DILUTE BINARY ALLOYS

    Institute of Scientific and Technical Information of China (English)

    S.H. Song; Z.X. Yuan; J. Liu; R.G.Faulkner

    2003-01-01

    Irradiation-induced grain boundary segregation of solute atoms frequently bring about grain boundary precipitation of a second phase because of its making the solubility limit of the solute surpassed at grain boundaries. Until now the kinetic models for irradiation-induced grain boundary precipitation have been sparse. For this reason, we have theoretically treated grain boundary precipitation under irradiation in dilute binary alloys. Predictions ofγ'-Ni3Si precipitation at grain boundaries ave made for a dilute Ni-Si alloy subjected to irradiation. It is demonstrated that grain boundary silicon segregation under irradiation may lead to grain boundaryγ'-Ni3 Si precipitation over a certain temperature range.

  19. High field Moessbauer study of dilute Ir-(Fe) alloys

    International Nuclear Information System (INIS)

    Takabatake, Toshiro; Mazaki, Hiromasa; Shinjo, Teruya.

    1981-01-01

    The magnetic behavior of very dilute Fe impurities in Ir has been studied by means of Moessbauer measurement in external fields up to 80 kOe at 4.2 K. The saturation hyperfine field increases in proportion to the external field up to the maximum magnetic field available. This means that for a localized spin fluctuation system IrFe, the effective magnetic moment associated with Fe impurities is induced in proportion to the external field. No anomalous spectrum was observed with a very dilute sample (--10 ppm 57 Co), indicating that the interaction between impurities is responsible for the anomalous spectrum previously observed with a less homogeneous sample. (author)

  20. Mechanistic model to predict colostrum intake based on deuterium oxide dilution technique data and impact of gestation and prefarrowing diets on piglet intake and sow yield of colostrum

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Flummer, Christine; Hurley, W L

    2014-01-01

    The aims of the present study were to quantify colostrum intake (CI) of piglets using the D2O dilution technique, to develop a mechanistic model to predict CI, to compare these data with CI predicted by a previous empirical predictive model developed for bottle-fed piglets, and to study how...... composition of diets fed to gestating sows affected piglet CI, sow colostrum yield (CY), and colostrum composition. In total, 240 piglets from 40 litters were enriched with D2O. The CI measured by D2O from birth until 24 h after the birth of first-born piglet was on average 443 g (SD 151). Based on measured...... CI, a mechanistic model to predict CI was developed using piglet characteristics (24-h weight gain [WG; g], BW at birth [BWB; kg], and duration of CI [D; min]: CI, g = –106 + 2.26 WG + 200 BWB + 0.111 D – 1,414 WG/D + 0.0182 WG/BWB (R2 = 0.944). This model was used to predict the CI for all colostrum...

  1. Determination of sulfur in steels by isotope dilution mass spectrometry after dissolution with sealed tube

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1981-01-01

    The scaled tube dissolution technique was studied for the complete conversion of sulfur in steels to sulfate. Isotope dilution mass spectrometry was used for the determination of sulfur in the sulfate. Sample (0.5 g) was dissolved in nitric acid (7 ml) and hydrochloric acid (3 ml) in a scaled borosilicate glass tube on being heated above 180 0 C overnight. Nitrate ions were removed by repeated evaporation with hydrochloric acid. The residue was dissolved in hydrochloric acid. Sulfate was reduced with a mixture of hydrochloric, hydroiodic and hypophosphorous acids; hydrogen sulfide evolved was absorbed in cadmium acetate solution, then converted to silver sulfide, which was burned to sulfur dioxide in pure oxygen at low pressure, for isotopic analysis. Analytical blank in whole procedure was 0.8 μg of sulfur. This technique was applied to the determination of sulfur in NBS low alloy steels. The principal cause of low values obtained by the open beaker dissolution technique was evaporation losses of sulfur as sulfur dioxide during the dissolution. (author)

  2. A theory of stable-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Pickup, J.F.; McPherson, C.K.

    1977-01-01

    In order to perform quantitative analysis using stable isotope dilution with mass spectrometry, an equation is derived which describes the relationship between the relative proportions of natural and labelled material and measured isotope ratios

  3. Development of isotope dilution gamma-ray spectrometry for plutonium analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, T.K.; Parker, J.L. (Los Alamos National Lab., NM (United States)); Kuno, Y.; Sato, S.; Kurosawa, A.; Akiyama, T. (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan))

    1991-01-01

    We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing {approximately}98% of {sup 239}Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

  4. A miniaturized plastic dilution refrigerator

    International Nuclear Information System (INIS)

    Bindilatti, V.; Oliveira, N.F.Jr.; Martin, R.V.; Frossati, G.

    1996-01-01

    We have built and tested a miniaturized dilution refrigerator, completely contained (still, heat exchanger and mixing chamber) inside a plastic (PVC) tube of 10 mm diameter and 170 mm length. With a 25 cm 2 CuNi heat exchanger, it reached temperatures below 50 mK, for circulation rates below 70 μmol/s. The cooling power at 100 mK and 63 μmol/s was 45 μW. The experimental space could accommodate samples up to 6 mm in diameter. (author)

  5. Dosage of plutonium by isotopic dilution in irradiated fuels; Dosage du plutonium par dilution isotopique dans les combustibles irradies

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Plutonium determination in irradiated fuels has been carried out for several years by isotopic dilution by Sebaci and SSM in collaboration. SECACI has made available to the SSM the necessary space and equipment in its Fontenay laboratories. This work has shown the importance of the valency cycle which should make it possible to obtain a uniform isotopic distribution in sample tracer mixtures, and also a satisfactory U/Pu separation. Now it has been noticed that the presence of an excess of uranium considerably modifies the oxidation-reduction reaction kinetics of the plutonium. We have therefore been led to change certain parts of the operational technique so as to have an efficient cycle and to thereby improve the U/Pu separation; the stability of the thermionic emission of the plutonium, connected to the quantity of residual uranium, has at the same time been improved and we can now carry out more precise isotopic analyses. We have also tried to eliminate as far as possible the isotopic contaminations by:using a more rational operational method; the equipment used has been the object of a special study. The evaporations are carried out so as to prevent the formation of saturated vapours inside the glove box. The material which cannot be changed after each operation is carefully cleaned every time a new sample is treated. With this technique, a second calibration of the tracer T{sub 2} has been undertaken using a new standard solution. This solution has been prepared very carefully by weighing uranium and plutonium of known chemical purity, and we believe that it can be guaranteed to be a good reference solution. The value of the {sup 233}U/{sup 242}Pu ratio of the tracer has been obtained with a relative accuracy of 0,5 per cent. This modified method is now being applied to the analysis of rods irradiated in G-3. (author) [French] La determination du plutonium par dilution isotopique dans les combustibles irradies est pratiquee depuis plusieurs annees en

  6. Dilution kicker for the SPS beam dump

    CERN Multimedia

    1974-01-01

    In order to reduce thermal stress on the SPS dump material, the fast-ejected beam was swept horizontally across the dump. This was done with the "dilution kicker" MKDH, still in use at the time of writing. The person on the left is Manfred Mayer. See also 7404072X.

  7. Opalescence in monoclonal antibody solutions and its correlation with intermolecular interactions in dilute and concentrated solutions.

    Science.gov (United States)

    Raut, Ashlesha S; Kalonia, Devendra S

    2015-04-01

    Opalescence indicates physical instability of a formulation because of the presence of aggregates or liquid-liquid phase separation in solution and has been reported for monoclonal antibody (mAb) formulations. Increased solution opalescence can be attributed to attractive protein-protein interactions (PPIs). Techniques including light scattering, AUC, or membrane osmometry are routinely employed to measure PPIs in dilute solutions, whereas opalescence is seen at relatively higher concentrations, where both long- and short-range forces contribute to overall PPIs. The mAb molecule studied here shows a unique property of high opalescence because of liquid-liquid phase separation. In this study, opalescence measurements are correlated to PPIs measured in diluted and concentrated solutions using light scattering (kD ) and high-frequency rheology (G'), respectively. Charges on the molecules were calculated using zeta potential measurements. Results indicate that high opalescence and phase separation are a result of the attractive interactions in solution; however, the presence of attractive interactions do not always imply phase separation. Temperature dependence of opalescence suggests that thermodynamic contribution to opalescence is significant and Tcloud can be utilized as a potential tool to assess attractive interactions in solution. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  8. Determination of zinc stable isotopes in biological materials using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Patterson, K.Y.; Veillon, Claude

    1992-01-01

    A method is described for using isotope dilution to determine both the amount of natural zinc and enriched isotopes of zinc in biological samples. Isotope dilution inductively coupled plasma mass spectrometry offers a way to quantify not only the natural zinc found in a sample but also the enriched isotope tracers of zinc. Accurate values for the enriched isotopes and natural zinc are obtained by adjusting the mass count rate data for measurable instrumental biases. Analytical interferences from the matrix are avoided by extracting the zinc from the sample matrix using diethylammonium diethyldithiocarbamate. The extraction technique separates the zinc from elements which form interfering molecular ions at the same nominal masses as the zinc isotopes. Accuracy of the method is verified using standard reference materials. The detection limit is 0.06 μg Zn per sample. Precision of the abundance ratios range from 0.3-0.8%. R.S.D. for natural zinc concentrations is about 200-600 μg g -1 . The accuracy and precision of the measurements make it possible to follow enriched isotopic tracers of zinc in biological samples in metabolic tracer studies. (author). 19 refs.; 1 fig., 4 tabs

  9. Effective field treatment of the annealed bond-dilute transverse Ising model

    International Nuclear Information System (INIS)

    Silva, P.R.; Sa Barreto, F.C. de

    1983-01-01

    The dilution of the spin-1/2 transverse Ising Model is studied by means of an effective field type treatment based on an extension of Callen's relation to the present model. The thermodynamics of the diluted model is obtained and the results are shown to be an improvement over the standard mean field treatment. The results are also compared with the Monte Carlo calculation for the spin-infinite transverse Ising Model. (Author) [pt

  10. Study of dilution of Spin-On Glass by Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Dominguez, Miguel; Rosales, Pedro; Torres, Alfonso; Moreno, Mario; Orduña, Abdu

    2012-01-01

    In this work, we study the dilution of Spin-On Glass (SOG) in order to obtain high quality SiO 2 films at 200 °C, with optical and electrical characteristics similar to those of the thermally grown SiO 2 . For the production of SiO 2 films we used 2-propanol and deionized water (DI) as diluents for the SOG and we compared the electrical and optical film properties with those of the films obtained from undiluted SOG. From Fourier transform infrared spectroscopy we observed a considerable reduction of Si-OH (920 cm −1 ), O-H (3490 cm −1 ) and C-H, C-O bonds (1139 cm −1 ) in the films produced from SOG diluted with DI. Besides the above, the insulator breakdown field was approximately 21 MV/cm, the refractive index and the dielectric constant were close to those of the thermally grown SiO 2 . Our results suggest that the film produced from SOG diluted with DI and cured at 200 °C is an excellent candidate to be used as insulator on flexible and large-area electronics. - Highlights: ► Preparation of high quality silicon oxide (SiO 2 ) films at 200 °C. ► Dilution of Spin-On Glass (SOG) solution was studied. ► Dilution of SOG is necessary to obtain high quality films annealed at 200 °C. ► n and k are close to those of the thermally grown SiO 2 .

  11. Limulus amebocyte lysate technique (LAL) for bacterial endotoxin control in radiodiagnosis agents (kits) and radioisotopes

    International Nuclear Information System (INIS)

    Morote, M.; Robles, A.; Ramos, B.; Otero, M.

    1997-01-01

    A procedure based on a fast technique of LAL individual kits has been devised to control bacterial endotoxins in radiodiagnosis agents (RDA): HEMTEC, DEIDA, PPI, AMD, GHCa, RENTEC, DMSA, MAA, TSC, HERTEC, DTPA, BRATEC and EDTMP as well as in radioisotopes I-131 and Tc99m. The procedures begins with the determination of the following values, injection volume (IV), endotoxin limits (EL), maximum valid dilution (MVD), total mass (TM), reconstitution volume (RV), concentration (mg/ml), and final dilution (FD). Subsequently, a procedure is carried out to conduct an 'in vitro' control of the radiodiagnosis agents and radioisotopes with LAL individual kits; the procedures includes: reconstitution of the sample to be controlled, dilution, inoculation of the diluted sample in LAL tubes and incubation at 37 o C for an hour. Finally, results are interpreted through the observation of gel formation or not in LAL tubes

  12. Sensitivity of the activated partial thromboplastin time, the dilute Russell's viper venom time, and the kaolin clotting time for the detection of the lupus anticoagulant: a direct comparison using plasma dilutions.

    Science.gov (United States)

    Martin, B A; Branch, D W; Rodgers, G M

    1996-01-01

    Increasing dilutions of lupus anticoagulant (LA) plasmas from twelve patients were used to directly compare the sensitivity of four tests for LA. The tests evaluated were the modified Bell and Alton activated partial thromboplastin time (APTT), an APTT using a commercially prepared partial thromboplastin (Platelin LS APTT), a modified dilute Russell's viper venom time (DRVVT), and a modified kaolin clotting time (KCT). LAs were detected in all twelve plasmas by each of three tests and eleven of twelve plasmas in a fourth test when undiluted patient plasma was used. Repeating the tests after diluting the LA plasmas with normal platelet-free plasma (PFP) showed that the KCT was the most sensitive test for LA, detecting eleven of twelve LAs at a dilution of 10% patient plasma and ten of twelve LAs at a dilution of 5% patient plasma. The modified Bell and Alton APTT and the modified DRVVT had similar sensitivities at a patient plasma concentration of 10%, detecting seven of twelve and eight of twelve LAs, respectively. The Platelin LS APTT detected only four of twelve LAs at a patient plasma concentration of 10%. Our results indicate that the modified KCT is a sensitive method for the detection of LAs. The modified Bell and Alton APTT and the DRVVT were less sensitive.

  13. Continuous deionization of a dilute nickel solution

    NARCIS (Netherlands)

    Spoor, P.B.; Koene, L.; Veen, ter W.R.; Janssen, L.J.J.

    2002-01-01

    This paper describes the continuous removal of nickel ions from a dilute solution using a hybrid ion-exchange/electrodialysis process. Emphasis was placed on the ionic state of the bed during the process, and the mass balance of ions in the system. Much of this information was obtained by analysing

  14. post-jomtien policy dilutions: infrastructural & quality norms

    Indian Academy of Sciences (India)

    Operation Blackboard norms diluted – from 3 teachers-3 rooms per primary school to 2 teachers-2 rooms per primary school. Regular teacher replaced by under-qualified, untrained, under-paid Para-teachers appointed on short-term contracts. EGS – No provision for school buildings or teaching aids. Multi-grade Teaching ...

  15. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    Directory of Open Access Journals (Sweden)

    Soriano Allan N.

    2017-01-01

    Full Text Available The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic’s anion.

  16. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    Science.gov (United States)

    Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran

    2017-11-01

    The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.

  17. Potential for boron dilution during small-break LOCAs in PWRs

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Cheng, Z.

    1995-01-01

    This paper documents the results of a scoping study of boron dilution and mixing phenomena during small break loss of coolant accidents (LOCAs) in pressurized water reactors (PWRs). Boron free condensate can accumulate in the cold leg loop seals when the reactor is operating in a reflux/boiler condenser mode. A problem may occur when the subsequent change in flow conditions such as loop seal clearing or re-establishment of natural circulation flow drive the diluted water in the loop seals into the reactor core without sufficient mixing with the highly borated water in the reactor downcomer and lower plenum. The resulting low boron concentration coolant entering the core may cause a power excursion leading to fuel failure. The mixing processes associated with a slow moving stream of diluted water through the loop seal to the core were examined in this report. A bounding evaluation of the range of boron concentration entering the core during a small break LOCA in a typical Westinghouse-designed, four-loop plant is also presented in this report

  18. Infinitely dilute partial molar properties of proteins from computer simulation.

    Science.gov (United States)

    Ploetz, Elizabeth A; Smith, Paul E

    2014-11-13

    A detailed understanding of temperature and pressure effects on an infinitely dilute protein's conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method's feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages.

  19. Husimi-cactus approximation study on the diluted spin ice

    Science.gov (United States)

    Otsuka, Hiromi; Okabe, Yutaka; Nefedev, Konstantin

    2018-04-01

    We investigate dilution effects on the classical spin-ice materials such as Ho2Ti2O7 and Dy2Ti2O7 . In particular, we derive a formula of the thermodynamic quantities as functions of the temperature and a nonmagnetic ion concentration based on a Husimi-cactus approximation. We find that the formula predicts a dilution-induced crossover from the cooperative to the conventional paramagnets in a ground state, and that it also reproduces the "generalized Pauling's entropy" given by Ke et al. To verify the formula from a numerical viewpoint, we compare these results with Monte Carlo simulation calculation data, and then find good agreement for all parameter values.

  20. A model for the viscosity of dilute smectite gels

    International Nuclear Information System (INIS)

    Liu, L.

    2011-01-01

    A simple yet accurate model describing the viscosity of dilute suspensions of sodium montmorillonite in dilute homo-ionic solutions is presented. Taking the clay particle and the surrounding clouds of ions as a whole as an uncharged but soft, coin-like particle, the Huggins' equation for a suspension of uncharged particles is extended in the model to account for not only the primary and the secondary electro-viscous effects, but also the multi-particle interaction. The agreements between the predicted and measured results are excellent. The Huggins' coefficient obtained compares favorably with available data, while the intrinsic viscosity reduces to the Simha's equation in the large limit of ionic strength, suggesting that the model is robust. (authors)

  1. Novel aspects of diluted and digital magnetic heterostructures

    International Nuclear Information System (INIS)

    Bonanni, A.

    1999-04-01

    In the present work novel aspects of diluted and digital II-VI-based heterostructures containing Mn ions are investigated. All the structures under study were fabricated by means of molecular beam epitaxy. Digital magnetic heterostructures have been prepared by incorporating discrete (sub)monolayers of the purely magnetic semiconductor MnTe into otherwise non magnetic CdTe quantum wells embedded in CdMgTe barriers. Formation and binding energy of magnetic polarons have been investigated in these structures and compared with the diluted case. Reflectance difference spectroscopy (RDS) performed ex-situ allowed to distinguish between signals due to the crystal anisotropy solely and those induced by the presence a magnetic elements. The problem of p-type doping of bulk diluted magnetic semiconductors II-VI-based is tackled. During and upon growth of ZnMnTe highly doped with N, in-situ RDS was carried out in order to investigate intra-ion transitions within the half filled 3d shell of Mn. Transport measurements and magnetometry at low temperature were performed to study, on the tracks of recent theoretical works, the influence of free carriers on the interaction between magnetic ions. As expected, indications of ferromagnetic ordering were found for the DMS with the highest concentration of carriers. Special attention was given to the formation of Mn islands on a II-VI substrate and to their change in morphology upon overgrowth with a mismatched material. A rich zoology of regularly shaped nanostructures could be produced. (author)

  2. Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS

    Science.gov (United States)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2005-04-01

    Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.

  3. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  4. The development and site investigation of fume diluter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bok Youn; Kang, Chang Hee; Jo, Young Do; Lim, Sang Taek [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    It is third project year on `Application of mobile diesel equipment in underground mines` for providing appropriate measures to improve underground working environment contaminated by the diesel exhaust pollutants. For reducing the exhaust temperature bellow 70 deg. C to prevent production of the governing pollutant (NO{sub 2}), the fume diluter is verified the most effective device through the site investigation. Therefore, the fume diluter is strongly recommended instead of catalytic converter which is employed presently. The performances derived from the tests are as follows; 1) This device increased air flow to 6.7-8.4 times of the original exhaust, 2) Exhaust temperature can be reduced to 66 deg. C from 161 deg. C, 3) All the pollutants can be reduced to bellow than 30 % of exhaust concentration, 4) This device requires less cost and no maintenance. (author). 4 tabs., 4 figs.

  5. Semi-passive pad (post-accident dilution) system combined with recombiners or igniters for e.g., multiple-unit VVER

    International Nuclear Information System (INIS)

    Eckardt, B.A.

    1997-01-01

    In order to reduce the risk associated with hypothetical severe nuclear accidents, it has been necessary to develop means for hydrogen control which are capable of handling high H 2 production rates of several m 3 /s. These systems and components should be of simple and, as far as possible, passive design. Moreover, their efficiency must not be affected by the H 2 production scenario. To meet these requirements, Siemens has supplemented its dual process for hydrogen reduction using recombiners and igniters by developing a new process: the semi-passive Post-Accident Dilution (PAD) System. The objective of the work presented in this paper was to design an alternative approach for hydrogen control comprising post-accident CO 2 dilution combined with recombiners or igniters for postulated severe accidents that result in significant hydrogen releases. The combined technique was to keep the dynamic loads arising inside the containment to within a range of only a few millibars, even in the event of transient hydrogen release and distribution processes accompanied by combustion, and was thus to prevent any hazard for safety-related equipment. (author)

  6. Kinetic-sound propagation in dilute gas mixtures

    International Nuclear Information System (INIS)

    Campa, A.; Cohen, E.G.D.

    1989-01-01

    Kinetic sound is predicted in dilute disparate-mass binary gas mixtures, propagating exclusively in the light compound and much faster than ordinary sound. It should be detectable by light-scattering experiments, as an extended shoulder in the scattering cross section for large frequencies. As an example, H 2 -Ar mixtures are discussed

  7. Effect of CO_2 dilution on combustion and emissions characteristics of the hydrogen-enriched gasoline engine

    International Nuclear Information System (INIS)

    Wang, Shuofeng; Ji, Changwei; Zhang, Bo; Cong, Xiaoyu; Liu, Xiaolong

    2016-01-01

    CO_2 (Carbon dioxide) dilution is a feasible way for controlling NOx (Nitrogen oxides) emissions and loads of the internal combustion engines. This paper investigated the effect of CO_2 dilution on the combustion and emissions characteristics of a hydrogen-enriched gasoline engine. The experiment was conducted on a 1.6 L spark-ignition engine with electronically controlled hydrogen and gasoline injection systems. At two hydrogen volume fractions of 0 and 3%, the CO_2 volume fraction in the intake was gradually increased from 0 to 4%. The fuel-air mixtures were kept at the stoichiometric. The experimental results demonstrated that brake mean effective pressure of the gasoline engine was quickly reduced after adopting CO_2 dilution. Comparatively, Bmep (Brake mean effective pressure) of the 3% hydrogen-enriched engine was gently decreased with the increase of CO_2 dilution level. Thermal efficiency of the 3% hydrogen-enriched gasoline engine was raised under properly increased CO_2 dilution levels. However, thermal efficiency of the pure gasoline engine was generally dropped after the CO_2 dilution. The addition of hydrogen could shorten flame development and propagation durations under CO_2 diluent conditions for the gasoline engine. Increasing CO_2 fraction in the intake caused the dropped NOx and raised HC (Hydrocarbon) emissions. Increasing hydrogen fraction in the intake could effectively reduce HC emissions under CO_2 diluent conditions. - Highlights: • CO_2 dilution reduces cooling loss and NOx of H_2-enriched gasoline engines. • H_2-blended gasoline engine gains better efficiency after CO_2 dilution. • CoVimep of H_2-blended gasoline engine is kept at low level after CO_2 addition. • CO_2 dilution has small effect on reducing Bmep of H_2-blended gasoline engine.

  8. Efficient removal of UDMH from dilute nitride MOCVD exhaust streams

    Science.gov (United States)

    Pahle, Jörg; Czerniak, Mike; Seeley, Andy; Baker, Derek

    2004-12-01

    Unsymmetrical dimethyl hydrazine (UDMH) (CH 3) 2N 2H 2 is often used in the deposition of dilute nitride semiconductors because it provides a source of nitrogen with a low thermal decomposition temperature (Temperature-dependent carrier lifetime in GaNAs using resonant-coupled photoconductive decay, NCPV Program Review Meeting, Lakewood, Colorado, 14-17 October, 2001). The problems with using this material, however, are its significant toxicity (0.01 ppm compared to ammonia's 25 ppm) and also the fact that it blocks the action of conventional dosed wet scrubbers sometimes used on nitride applications, resulting in diminished efficiency in removing arsine (the source of arsenic), and arsine being similarly toxic (TLV of 0.05 ppm). Efficient removal of UDMH, AsH 3 and hydrogen (which, though not toxic poses a potential safety hazard) by means of a combined thermal oxidation reaction and wet scrubber in series is described at input gas flow rates exceeding those typically encountered in practice. The detection technique employed was Fourier transform infra red spectroscopy (FTIR), and the calibration and resolution techniques will be described. For input UDMH flows of up to 445 sccm (i.e. 1.85×10 -2 mol/min), destructive reaction efficiencies (DREs) of >99.9% were demonstrated, corresponding to the background detection resolution of 0.4 ppm.

  9. A report on the aquatic dilution experiment carried out at discharge canal, KGS site

    International Nuclear Information System (INIS)

    Reji, T.K.; Nayak, P.D.; Sudhakar, J.; Ajith, T.L.; Vishnu, M.S.; Ravi, P.M.; James, J.P.; Joshi, R.M.; Naik, S.B.; Kudtharkar, A.M.; Gaonkar, S.M.; Verma, P.C.; Datta, D.; Dahiya, Sudhir; Brijkumar; Datta, Maduparna; Sajeevan, G.

    2009-08-01

    Under Nuclear Power Corporation of India Limited (NPCIL), three units of (each of capacity 220MWe) Nuclear Power Stations are operational and one unit of similar capacity is under advanced stage of construction at Kaiga site. The radioactive liquid effluents generated in the plant are diluted with Condenser Coolant Water Stream (CCW) which is then discharged into Kadra reservoir through an artificially made discharge canal. The basic objective of the present study is to estimate the Dilution Factors at various locations of discharge canal and to understand the process of dilution and dispersion of radioactive effluent in the discharge canal. The strategy of the experiment involved the collection of samples from discharge canal lengthwise, breadth wise and depth wise immediately after the routine release of one of the batches of effluent stream into the CCW stream. No additional activity was released for the purpose of this experiment. The study compared the experimentally obtained Dilution Factor with that calculated based on the flow rates of CCW pumps and active liquid effluent discharge pumps. In the present conditions of experiment, Dilution Factor, based on flow rates of CCW pumps and Liquid Effluent Discharge pump, works out to be 8.11 E -05 while experimentally observed Mean Dilution Factor in the discharge canal works out to be (7.75±2.15) E-05. Hence this experiment clearly demonstrate the validity of the method of calculating dilution factor based on the flow rates of CCW line and that of Effluent discharge pump. The data analysis indicates that mass flow seems to be the major process of dispersion in the discharge canal. The tritium activity was found to be moving faster in the midstream as compared to that near the shore. The conclusions are drawn purely based on experimental results. This experimental data can be used for validation of aquatic dispersion models. (author)

  10. A simple preparation of calibration curve standards of 134Cs and 137Cs by serial dilution of a standard reference material

    International Nuclear Information System (INIS)

    Labrecque, J.J.; Rosales, P.A.

    1990-01-01

    Two sets of calibration standards for 134 Cs and 137 Cs were prepared by small serial dilution of a natural matrix standard reference material, IAEA-154 whey powder. The first set was intended to screen imported milk powders which were suspected to be contaminated with 134 Cs and 137 Cs. Their concentration ranged from 40 to 400 Bq/kg. The other set of calibration standards was prepared to measure the environmental levels of 137 Cs in commercial Venezuelan milk powders. Their concentration ranged from 3 to 10 Bq/kg of 137 Cs. The accuracy of these calibration curves was checked by IAEA-152 and A-14 milk powders. Their measured values were in good agreement with their certified values. Finally, it is shown that these preparation techniques using serial dilution of a standard reference material were simple, rapid, precise, accurate and cost-effective. (author) 5 refs.; 5 figs.; 3 tabs

  11. ACTIVITY OF LEAF-CUTTING ANT Atta sexdens piriventris SUBMITED TO HIGH DILUTION HOMEOPATHIC PREPARATIONS

    Directory of Open Access Journals (Sweden)

    Alexandre Giesel

    2013-02-01

    Full Text Available The effect of high dilution preparations on the movement and foraging activities of Atta sexdens piriventris was evaluated. Five colonies of ants were located on each of the five experimental areas using a randomized complete block design. Three main forage trails from each colony were selected from where evaluations were made. Ten mL of high dilution preparation of Atta sexdens piriventris nosodes and Belladonna homeopathy solution were sprayed over 0.5 m of each selected trail, 1.0 m far from the nest. The controls were pure water and non treated trails. Applications were made daily during 10 days. The total number of ants moving on each trail one meter away from the nest, carrying or not plant fragments, were assessed before the daily application. Dilution preparations at 30CH (thirtieth centesimal Hahnemannian dilution of A. sexdens piriventris nosodes and Belladonna reduced the activities of ants from the fifth day after the first application. The treatment effect lasted more than 20 days after the last application. The use of preparation at 30CH dilution order to reduce the foraging activity of leaf-cutting ants is a potential non residual method to manage leaf-cutting ants.

  12. Dilution-Induced Formation of Hybrid Perovskite Nanoplatelets.

    Science.gov (United States)

    Tong, Yu; Ehrat, Florian; Vanderlinden, Willem; Cardenas-Daw, Carlos; Stolarczyk, Jacek K; Polavarapu, Lakshminarayana; Urban, Alexander S

    2016-12-27

    Perovskite nanocrystals (NCs) are an important extension to the fascinating field of hybrid halide perovskites. Showing significantly enhanced photoluminescence (PL) efficiency and emission wavelengths tunable through halide content and size, they hold great promise for light-emitting applications. Despite the rapid advancement in this field, the physical nature and size-dependent excitonic properties have not been well investigated due to the challenges associated with their preparation. Herein we report the spontaneous formation of highly luminescent, quasi-2D organic-inorganic hybrid perovskite nanoplatelets (NPls) upon dilution of a dispersion of bulk-like NCs. The fragmentation of the large NCs is attributed to osmotic swelling induced by the added solvent. An excess of organic ligands in the solvent quickly passivates the newly formed surfaces, stabilizing the NPls in the process. The thickness of the NPls can be controlled both by the dilution level and by the ligand concentration. Such colloidal NPls and their thin films were found to be extremely stable under continuous UV light irradiation. Full tunability of the NPl emission wavelength is achieved by varying the halide ion used (bromide, iodide). Additionally, time-resolved PL measurements reveal an increasing radiative decay rate with decreasing thickness of the NPls, likely due to an increasing exciton binding energy. Similarly, measurements on iodide-containing NPls show a transformation from biexponential to monoexponential PL decay with decreasing thickness, likely due to an increasing fraction of excitonic recombination. This interesting phenomenon of change in fluorescence upon dilution is a result of the intricate nature of the perovskite material itself and is uncommon in inorganic materials. Our findings enable the synthesis of halide perovskite NCs with high quantum efficiency and good stability as well as a tuning of both their optical and morphological properties.

  13. Capsize of polarization in dilute photonic crystals.

    Science.gov (United States)

    Gevorkian, Zhyrair; Hakhoumian, Arsen; Gasparian, Vladimir; Cuevas, Emilio

    2017-11-29

    We investigate, experimentally and theoretically, polarization rotation effects in dilute photonic crystals with transverse permittivity inhomogeneity perpendicular to the traveling direction of waves. A capsize, namely a drastic change of polarization to the perpendicular direction is observed in a one-dimensional photonic crystal in the frequency range 10 ÷ 140 GHz. To gain more insights into the rotational mechanism, we have developed a theoretical model of dilute photonic crystal, based on Maxwell's equations with a spatially dependent two dimensional inhomogeneous dielectric permittivity. We show that the polarization's rotation can be explained by an optical splitting parameter appearing naturally in Maxwell's equations for magnetic or electric fields components. This parameter is an optical analogous of Rashba like spin-orbit interaction parameter present in quantum waves, introduces a correction to the band structure of the two-dimensional Bloch states, creates the dynamical phase shift between the waves propagating in the orthogonal directions and finally leads to capsizing of the initial polarization. Excellent agreement between theory and experiment is found.

  14. Chaotic properties of dilute two- and three dimensional random Lorentz gases: Equilibrium systems

    NARCIS (Netherlands)

    van Beijeren, H.; Latz, A.; Dorfman, J.R.

    We compute the Lyapunov spectrum and the Kolmogorov-Sinai entropy for a moving particle placed in a dilute, random array of hard-disk or hard-sphere scatterers, i.e., the dilute Lorentz gas model. This is carried out in two ways. First we use simple kinetic theory arguments to compute the Lyapunov

  15. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    Science.gov (United States)

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  16. Microstructure and Physical Metallurgy in Melt-Dilute Treatment Technology for Al-Based Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Adams, T.M.; Peacock, H.B.

    1998-09-01

    Major challenges associated with the direct disposal of research reactor fuel in a repository include nonproliferation and criticality control, both of which may be a concern for HEU Al-SNF. Consideration must be given to the potential desirability and/or regulatory necessity of diluting the HEU SNF to below 20 percent enrichment. The probability for a criticality event as well as the issue of proliferation are greatly decreased by reducing the enrichment. The melt-dilute technology development program is focused on the development and implementation of a treatment technology for diluting HEU Al-SNF to LEU levels and qualifying this LEU Al-SNF form for geologic repository storage. An attribute of the melt-dilute process is its applicability to various types of FRR and DRR SNF

  17. The diluted tri-dimensional spin-one Ising model with crystal field interactions

    International Nuclear Information System (INIS)

    Saber, M.

    1988-09-01

    3D spin-one Ising models with nearest-neighbour ferromagnetic interactions with crystal-field exhibit tricritical behaviour. A new method that applies to a wide class of random systems is used to study the influence of site and bond dilution on this behaviour. We have calculated temperature-crystal-field-concentration phase diagrams and determined, in particular, the influence of dilution on the zero temperature tricritical temperature. (author). 10 refs, 8 figs

  18. Study of oxygen diluted silane plasmas applied for the deposition of silicium oxyde

    International Nuclear Information System (INIS)

    Magni, D.

    2001-09-01

    Plasma enhanced chemical vapour deposition of thin films such as silicon dioxide is used in many applications such as the insulator production in semiconductor technology or anticorrosion coating in packaging industry as a substitute for aluminium which is less ecological. Oxygen diluted silane plasmas are often utilized to produce SiO 2 film, but the tendency is to work with organosilicon precursors such as HMDSO (hexamethyldisiloxane ) described as non-toxic and requiring less stringent safety and costly installation. In this study, the species in gaseous phase and the powder produced in oxygen-diluted HMDSO plasmas were experimentally characterized in a radiofrequency (RF) capacitively-coupled reactor at 13.56 MHz. Some aspects of plasma enhanced deposition of SiO 2 were studied in a RF magnetron reactor . The gaseous phase of the oxygen-diluted plasmas were studied by infrared absorption spectroscopy and mass spectrometry .The complementarity of these diagnostics allowed to show that the dominant species in gaseous phase come from the homogeneous reaction between oxygen and the radical CH x (with x 1,2 and 3), abundantly produced in the plasma. Two principal pathways were shown to occur. A first way leads to hydrocarbon formation such as methane (CH 4 ) and acetylene (C 2 H 2 ), whose partial pressures are close to 2 %. A second way leads to the formation of molecules from the combustion of CH x , such as formaldehyde (CH 2 O), formic acid (CH 2 O 2 ), carbon monoxide (CO), carbon dioxide (CO 2 ) and water. Moreover it is shown that the CO 2 results from a heterogeneous reaction between the carbon on the surfaces and the oxygen coming from the plasma. At low dilution conditions, the partial pressures of CO and CO 2 were estimated at 25 and 10 % of the total pressure respectively. In argon or helium diluted HMDSO plasmas, methane, acetylene and hydrogen are the main stable molecules produced in the gaseous phase. Particle formation in oxygen-diluted HMDSO

  19. Evaluation of feeds for melt and dilute process using an Analytical Hierarchy Process

    International Nuclear Information System (INIS)

    Krupa, J.F.

    2000-01-01

    WSRC was requested to evaluate whether nuclear materials other than aluminum-clad spent nuclear fuel should be considered for treatment to prepare them for disposal in the melt and dilute facility as part of the Treatment and Storage Facility (TSF) currently projected for construction in the L-Reactor process area. The Analytical Hierarchy Process using a ratings methodology was used to rank potential feed candidates for disposition through the Melt and Dilute facility proposed for disposition of Savannah River Site aluminum-clad spent nuclear fuel. Because of the scoping nature of this analysis, the expert team convened for this purpose concentrated on technical feasibility and potential cost impacts associated with using melt and dilute versus the current disposition option

  20. Isotope dilution alpha spectrometry for the determination of plutonium concentration in irradiated fuel dissolver solution : IDAS and R-IDAS

    International Nuclear Information System (INIS)

    Ramaniah, M.V.; Jain, H.C.; Aggarwal, S.K.; Chitambar, S.A.; Kavimandan, V.D.; Almaula, A.I.; Shah, P.M.; Parab, A.R.; Sant, V.L.

    1980-01-01

    The report presents a new technique, Isotope Dilution Alpha Spectrometry (IDAS) and Reverse Isotope Dilution Alpha Spectrometry (R-IDAS) for determining the concentration of plutonium in the irradiated fuel dissolver solution. The method exploits sup(238)Pu in IDAS and sup(239)Pu in R-IDAS as a spike and provides an alternative method to Isotope Dilution Mass Spectrometry (IDMS) which requires enriched sup(242)Pu as a spike. Depending upon the burn-up of the fuel, sup(238)Pu or sup(239)Pu is used as a spike to change the sup(238)Pu/(sup(239)Pu+sup(240)Pu)α activity ratio in the sample by a factor of 10. This change is determined by α-spectrometry on electrodeposited sources using a solid state silicon surface barrier detector coupled to a multichannel analyser. The validity of a simple method based on the geometric progression (G.P.) decrease for the far tail of the spectrum to correct for the tail contribution of sup(238)Pu peak (5.50 MeV) to the low energy sup(239)Pu + sup(240)Pu peak (5.17 MeV) is established. Results for the plutonium concentration on different irradiated fuel dissolver solutions with burn-uo ranging from J,000 to 100,000 MWD/TU are presented and compared with those obtained by IDMS. The values obtained by IDAS or R-IDAS and IDMS agree within 0.5%. (auth.)

  1. Crystal Fields in Dilute Rare-Earth Metals Obtained from Magnetization Measurements on Dilute Rare-Earth Alloys

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.

    1974-01-01

    Crystal field parameters of Tb, Dy, and Er in Sc, Y, and Lu are summarized. These parameters are obtained from magnetization measurements on dilute single crystals, and successfully checked by a number of different methods. The crystal field parameters vary unpredictably with the rare-earth solute....... B40, B60, and B66 are similar in Y and Lu. Crystal field parameters for the pure metals Tb, Dy, and Er are estimated from the crystal fields in Y and Lu....

  2. Study of dilution of Spin-On Glass by Fourier transform infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez, Miguel, E-mail: mdominguez@inaoep.mx [National Institute for Astrophysics, Optics and Electronics (INAOE), Electronics Department, Luis Enrique Erro No. 1, Puebla 72840 (Mexico); Rosales, Pedro; Torres, Alfonso; Moreno, Mario [National Institute for Astrophysics, Optics and Electronics (INAOE), Electronics Department, Luis Enrique Erro No. 1, Puebla 72840 (Mexico); Orduna, Abdu [CIBA-Tlaxcala, Instituto Politecnico Nacional, Tepetitla, Tlax. 90700 (Mexico)

    2012-05-31

    In this work, we study the dilution of Spin-On Glass (SOG) in order to obtain high quality SiO{sub 2} films at 200 Degree-Sign C, with optical and electrical characteristics similar to those of the thermally grown SiO{sub 2}. For the production of SiO{sub 2} films we used 2-propanol and deionized water (DI) as diluents for the SOG and we compared the electrical and optical film properties with those of the films obtained from undiluted SOG. From Fourier transform infrared spectroscopy we observed a considerable reduction of Si-OH (920 cm{sup -1}), O-H (3490 cm{sup -1}) and C-H, C-O bonds (1139 cm{sup -1}) in the films produced from SOG diluted with DI. Besides the above, the insulator breakdown field was approximately 21 MV/cm, the refractive index and the dielectric constant were close to those of the thermally grown SiO{sub 2}. Our results suggest that the film produced from SOG diluted with DI and cured at 200 Degree-Sign C is an excellent candidate to be used as insulator on flexible and large-area electronics. - Highlights: Black-Right-Pointing-Pointer Preparation of high quality silicon oxide (SiO{sub 2}) films at 200 Degree-Sign C. Black-Right-Pointing-Pointer Dilution of Spin-On Glass (SOG) solution was studied. Black-Right-Pointing-Pointer Dilution of SOG is necessary to obtain high quality films annealed at 200 Degree-Sign C. Black-Right-Pointing-Pointer n and k are close to those of the thermally grown SiO{sub 2}.

  3. The effect of dilution on the gas retention behavior of Tank 241-SY- 103 waste

    International Nuclear Information System (INIS)

    Bredt, P.R.; Tingey, S.M.

    1996-01-01

    Twenty-five of the 177 underground waste storage tanks on the Hanford Site have been placed on the Flammable Gas watch list. These 25 tanks, containing high-level waste generated during plutonium and uranium processing, have been identified as potentially capable of accumulating flammable gases above the lower flammability limit (Babad et al. 1991). In the case of Tanks 241-SY-101 and 241-SY-103, it has been proposed that diluting the tank waste may mitigate this hazard (Hudson et al. 1995; Stewart et al. 1994). The effect of dilution on the ability of waste from Tank 241-SY-103 to accumulate gas was studied at Pacific Northwest National Laboratory. A similar study has been completed for waste from Tank 241-SY-101 (Bredt et al. 1995). Because of the additional waste-storage volume available in Tank 241-SY-103 and because the waste is assumed to be similar to that currently in Tank 241-SY-101, Tank 241-SY-103 became the target for a demonstration of passive mitigation through in-tank dilution. In 1994, plans for the in-tank dilution demonstration were deferred pending a decision on whether to pursue dilution as a mitigation strategy. However, because Tank 241-SY-103 is an early retrieval target, determination of how waste properties vary with dilution will still be required

  4. Mass spectrometric isotope dilution analyses of palladium, silver, cadmium and tellurium in carbonaceous chondrites

    International Nuclear Information System (INIS)

    Loss, R.D.; Rosman, K.J.R.; De Laeter, J.

    1984-01-01

    The mass spectrometric isotope dilution technique was used to measure the elemental abundances of Pd, Ag, Cd and Te in Orgueil (C1), Ivuna (C1), Murray (C2) and Allende (C3) chondrites. The Pd abundance of 554 ppb for the Cl chondrites is almost identical to the recommended value of Anders and Ebihara (1982); that for Cd (712 ppb) is approximately 5% higher, whereas that for Ag (198 ppb) is approximately 10% lower than the recommended values. A smooth distribution for the abundances of the odd-A nuclides between 65 128 Te and 130 Te to lie approximately 30% above the r-process peak at A = 130, whereas the new value fits smoothly into the general trend. (author)

  5. An investigation of tungsten by neutron activation techniques

    International Nuclear Information System (INIS)

    Svetsreni, R.

    1978-01-01

    This investigation used neutron from Plutonium-Beryllium source (5 curie) to analyse the amount of tungsten in tungsten oxide which was extracted from tungsten ores, slag and tungsten alloy of tungsten iron and carbon. The technique of neutron activation analysis with NaI(Tl) gamma detector 3'' x 3'' and 1024 multichannel analyzer. The dilution technique was used by mixing Fe 2 O 3 or pure sand into the sample before irradiation. In this study self shielding effect in the analysis of tungsten was solved and the detection limit of the tungsten in the sample was about 0.5%

  6. Worldwide estimation of river concentrations of any chemical originating from sewage-treatment plants using dilution factors.

    Science.gov (United States)

    Keller, Virginie D J; Williams, Richard J; Lofthouse, Caryn; Johnson, Andrew C

    2014-02-01

    Dilution factors are a critical component in estimating concentrations of so-called "down-the-drain" chemicals (e.g., pharmaceuticals) in rivers. The present study estimated the temporal and spatial variability of dilution factors around the world using geographically referenced data sets at 0.5° × 0.5° resolution. Domestic wastewater effluents were derived from national per capita domestic water use estimates and gridded population. Monthly and annual river flows were estimated by accumulating runoff estimates using topographically derived flow directions. National statistics, including the median and interquartile range, were generated to quantify dilution factors. Spatial variability of the dilution factor was found to be considerable; for example, there are 4 orders of magnitude in annual median dilution factor between Canada and Morocco. Temporal variability within a country can also be substantial; in India, there are up to 9 orders of magnitude between median monthly dilution factors. These national statistics provide a global picture of the temporal and spatial variability of dilution factors and, hence, of the potential exposure to down-the-drain chemicals. The present methodology has potential for a wide international community (including decision makers and pharmaceutical companies) to assess relative exposure to down-the-drain chemicals released by human pollution in rivers and, thus, target areas of potentially high risk. © 2013 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals, Inc. on behalf of SETAC.

  7. Disposal of Low-Activity Liquid Effluents by Dilution

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Candillon, C. [Atomic Energy Commission, Saclay (France)

    1960-07-01

    Nuclear centres are frequently faced with problems of disposal of sizeable quantities of low-activity liquid effluents. Under present conditions the most practicable solution seems to be to discharge them into a natural or artificial water system, so as to dilute them as much as possible and thus reduce their radioactive isotope content below the public health levels. This technique is employed by all nuclear centres in France, which use the following convenient outlets: Saclay: the artificial ponds made by Louis XIV to feed the great Versailles fountains; Fontenay-aux-Roses: the Paris sewer system; Grenoble: the river Isere; Marcoule: the river Rhone. Until 1957 the amount of waste was negligible. It is still very slight at the first three centres, only a few dozen millicuries a month. At Marcoule the activity of the effluents is somewhat greater, but the Rhone's rate of flow ensures a very low final content of radioactive elements. The increasing discharge of wastes into river systems calls for a close watch on changes in radioactivity in the environment (i.e. in air, water and soil), and especially on areas in which radioactive isotopes may accumulate. We have therefore made laboratory studies of the mechanics of radioactivity concentration, in order to improve our sampling methods and ascertain the movement of wastes.

  8. Isotopic dilution methods to determine the gross transformation rates of nitrogen, phosphorus, and sulfur in soil: a review of the theory, methodologies, and limitations

    International Nuclear Information System (INIS)

    Di, H. J.; Cameron, K. C.; McLaren, R. G.

    2000-01-01

    The rates at which nutrients are released to, and removed from, the mineral nutrient pool are important in regulating the nutrient supply to plants. These nutrient transformation rates need to be taken into account when developing nutrient management strategies for economical and sustainable production. A method that is gaining popularity for determining the gross transformation rates of nutrients in the soil is the isotopic dilution technique. The technique involves labelling a soil mineral nutrient pool, e.g. NH 4 + , NO 3 - , PO 4 3- , or SO 4 2- , and monitoring the changes with time of the size of the labelled nutrient pool and the excess tracer abundance (atom %, if stable isotope tracer is used) or specific activity (if radioisotope is used) in the nutrient pool. Because of the complexity of the concepts and procedures involved, the method has sometimes been used incorrectly, and results misinterpreted. This paper discusses the isotopic dilution technique, including the theoretical background, the methodologies to determine the gross flux rates of nitrogen, phosphorus, and sulfur, and the limitations of the technique. The assumptions, conceptual models, experimental procedures, and compounding factors are discussed. Possible effects on the results by factors such as the uniformity of tracer distribution in the soil, changes in soil moisture content, substrate concentration, and aeration status, and duration of the experiment are also discussed. The influx and out-flux transformation rates derived from this technique are often contributed by several processes simultaneously, and thus cannot always be attributed to a particular nutrient transformation process. Despite the various constraints or possible compounding factors, the technique is a valuable tool that can provide important quantitative information on nutrient dynamics in the soil-plant system. Copyright (2000) CSIRO Publishing

  9. Grad-type fourteen-moment theory for dilute granular gases

    Indian Academy of Sciences (India)

    2Department of Mathematics, Indian Institute of Technology Madras, Chennai 600 036, India ... practically no effect on Haff's law. ... Stokes, and Fourier (NSF) laws for dilute granular ...... and PS gratefully acknowledges financial support from.

  10. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  11. Electrochemical reduction of nickel ions from dilute solutions

    NARCIS (Netherlands)

    Njau, K.N.; Janssen, L.J.J.

    1995-01-01

    Electrochemical reduction of nickel ions in dilute solution using a divided GBC-cell is of interest for purification of waste waters. A typical solution to be treated is the effluent from steel etching processes which contain low quantities of nickel, chromate and chromium ions. Reduction of

  12. Analyses of turbulent flow fields and aerosol dynamics of diesel engine exhaust inside two dilution sampling tunnels using the CTAG model.

    Science.gov (United States)

    Wang, Yan Jason; Yang, Bo; Lipsky, Eric M; Robinson, Allen L; Zhang, K Max

    2013-01-15

    Experimental results from laboratory emission testing have indicated that particulate emission measurements are sensitive to the dilution process of exhaust using fabricated dilution systems. In this paper, we first categorize the dilution parameters into two groups: (1) aerodynamics (e.g., mixing types, mixing enhancers, dilution ratios, residence time); and (2) mixture properties (e.g., temperature, relative humidity, particle size distributions of both raw exhaust and dilution gas). Then we employ the Comprehensive Turbulent Aerosol Dynamics and Gas Chemistry (CTAG) model to investigate the effects of those parameters on a set of particulate emission measurements comparing two dilution tunnels, i.e., a T-mixing lab dilution tunnel and a portable field dilution tunnel with a type of coaxial mixing. The turbulent flow fields and aerosol dynamics of particles are simulated inside two dilution tunnels. Particle size distributions under various dilution conditions predicted by CTAG are evaluated against the experimental data. It is found that in the area adjacent to the injection of exhaust, turbulence plays a crucial role in mixing the exhaust with the dilution air, and the strength of nucleation dominates the level of particle number concentrations. Further downstream, nucleation terminates and the growth of particles by condensation and coagulation continues. Sensitivity studies reveal that a potential unifying parameter for aerodynamics, i.e., the dilution rate of exhaust, plays an important role in new particle formation. The T-mixing lab tunnel tends to favor the nucleation due to a larger dilution rate of the exhaust than the coaxial mixing field tunnel. Our study indicates that numerical simulation tools can be potentially utilized to develop strategies to reduce the uncertainties associated with dilution samplings of emission sources.

  13. Studies on the Ecological Adaptability of Growing Rice with Floating Bed on the Dilute Biogas Slurry

    Science.gov (United States)

    Du, Qi; Cheng, Bowen; Liao, Zhiqi; Sun, Chengcheng

    2016-01-01

    This study aimed to explore the ecological adaptability and the possibility of growing rice with floating bed on the dilute biogas slurry. The results of the experiments show that the growth stage, rice plant height, and rice yield and quality were significantly affected by multiple dilutions; rice plants cultivated with 45 multiple dilutions had better ecological adaptability than others. In the 45 multiple dilutions' group, the yield of rice was 13.3 g/bucket (8 rice plants), milled rice rate was 63.1%, and the content of crude protein in the rice was 6.3%. The concentrations of heavy metals in the rice cultivated with 30 multiple dilutions' slurry, such as total lead, cadmium, mercury, chromium, and arsenic, were all below the national standard. The study shows that it is possible and safe to cultivate rice plants with no soil but diluted biogas slurry. In the experiments, the yield, milled rice rate, and crude protein of the rice cultivated with slurry were not as much as those of rice cultivated with regular way in soil. This study provides the basic theoretical support for the development of biogas projects and the potential achievement of organic farming in special agricultural facilities and circular economy. PMID:27882324

  14. Studies on the Ecological Adaptability of Growing Rice with Floating Bed on the Dilute Biogas Slurry.

    Science.gov (United States)

    Kang, Qun; Li, Rui; Du, Qi; Cheng, Bowen; Liao, Zhiqi; Sun, Chengcheng; Li, Zhaohua

    2016-01-01

    This study aimed to explore the ecological adaptability and the possibility of growing rice with floating bed on the dilute biogas slurry. The results of the experiments show that the growth stage, rice plant height, and rice yield and quality were significantly affected by multiple dilutions; rice plants cultivated with 45 multiple dilutions had better ecological adaptability than others. In the 45 multiple dilutions' group, the yield of rice was 13.3 g/bucket (8 rice plants), milled rice rate was 63.1%, and the content of crude protein in the rice was 6.3%. The concentrations of heavy metals in the rice cultivated with 30 multiple dilutions' slurry, such as total lead, cadmium, mercury, chromium, and arsenic, were all below the national standard. The study shows that it is possible and safe to cultivate rice plants with no soil but diluted biogas slurry. In the experiments, the yield, milled rice rate, and crude protein of the rice cultivated with slurry were not as much as those of rice cultivated with regular way in soil. This study provides the basic theoretical support for the development of biogas projects and the potential achievement of organic farming in special agricultural facilities and circular economy.

  15. Mass spectrometic isotope dilution analysis of Am and Cm in spent fuels

    International Nuclear Information System (INIS)

    Wantschik, M.; Koch, L.; Commission of the European Communities, Karlsruhe; Ganser, B.

    1983-01-01

    Spent nuclear fuels contain Am and Cm in the 10 ppb to 100 ppm range. Because of this low abundance and the necessity of handling small samples of the highly toxic fuel material only a mass-spectrometric isotope dilution analysis can give sufficiently accurate results. Since suitable spikes and/or standards have been lacking, this method has not been applied. Using known masses (+- 0.1%) of Am-241 and Cm-244 metal, Am-243 and Cm-248 spikes were calibrated to an accuracy of better than 0.2%. The standards were reanalysed by chemical titration and several radiometric techniques. The chemical conditioning is based on ionexchange chromatography with alpha-hydroxyisobutyric acid. A sample size of 10 -7 g is sufficient. For the mass-spectrometric measurement 10 -9 g of the elements are required. The accuracy for the determination of the main isotope is 0.5%. (orig./BRB)

  16. A compact dilution refrigerator with vertical heat exchangers for operation to 2 mK

    International Nuclear Information System (INIS)

    Bunkov, Yu.M.; Guenault, A.M.; Hayward, D.J.; Jackson, D.A.; Kennedy, C.J.; Nichols, T.R.; Miller, I.E.; Pickett, G.R.; Ward, M.G.

    1991-01-01

    A compactly designed dilution refrigerator with closely packed, vertical heat exchangers is described. The refrigerator reaches a temperature of 2 mK and is easily constructed, since the sintered heat exchangers are straight units. Vibrating wire resonators are employed in the mixing chamber as diagnostic tools, which may act as both thermometers and phase-boundary level indicators. There is a design problem in the vertical arrangement, namely, the sumps on the concentrated phase side that can slowly fill with dilute phase and degrade the performance. The problem is solved by draining the superfluid 4 He component in any collected dilute phase through superleaks into the mixing chamber

  17. Optimal sample to tracer ratio for isotope dilution mass spectrometry: the polyisotopic case

    International Nuclear Information System (INIS)

    Laszlo, G.; Ridder, P. de; Goldman, A.; Cappis, J.; Bievre, P. de

    1991-01-01

    The Isotope Dilution Mass Spectrometry (IDMS) measurement technique provides a means for determining the unknown amount of various isotopes of an element in a sample solution of known mass. The sample solution is mixed with an auxiliary solution, or tracer, containing a known amount of the same element having the same isotopes but of different relative abundances or isotopic composition and the induced change in the isotopic composition measured by isotope mass spectrometry. The technique involves the measurement of the abundance ratio of each isotope to a (same) reference isotope in the sample solution, in the tracer solution and in the blend of the sample and tracer solution. These isotope ratio measurements, the known element amount in the tracer and the known mass of sample solution are used to calculate the unknown amount of one isotope in the sample solution. Subsequently the unknown amount of element is determined. The purpose of this paper is to examine the optimization of the ratio of the estimated unknown amount of element in the sample solution to the known amount of element in the tracer solution in order to minimize the relative uncertainty in the determination of the unknown amount of element

  18. Ring Keratitis Associated With Topical Abuse of a Dilute Anesthetic After Refractive Surgery

    Directory of Open Access Journals (Sweden)

    Yu-Chih Hou

    2009-12-01

    Full Text Available Anesthetic toxic keratitis is rare and presents as a ring keratitis, which is often misdiagnosed as Acanthamoeba keratitis. Here, we report an unusual case of toxic keratitis caused by topical abuse of a dilute anesthetic. A 26-year-old woman presented with bilateral corneal edema, ring infiltrates, pigmented keratic precipitate, Descemet's membrane folding, and strong anterior chamber reactions 2 weeks after laser subepithelial keratomileusis surgery. Tracing back her medical history, topical dilute 0.1% proparacaine was prescribed and frequently used for 1 month. Toxic keratitis was suspected. After discontinuation of the topical anesthetic and initiation of treatment with topical 20% autologous serum, complete corneal epithelialization was achieved within 1 week. Corneal infiltrates and anterior chamber reaction gradually subsided. Vision improved from finger counting to 20/20 in the right eye and 20/25 in the left eye, but confocal microscopy showed decreased corneal endothelial cells. Topical abuse of a dilute topical anesthetic can cause severe toxic keratitis and endothelial cell loss. The physician must be aware of the signs of topical anesthetic abuse and should not prescribe even a dilute anesthetic for long-term use. Autologous serum can help in the recovery of toxic keratitis.

  19. Development of melt dilute technology for disposition of aluminum based spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Swift, W.F. [Nuclear Material Management Division Westinghouse Savannah River Company, Savannah River Site Building 707-C, Aiken, SC 29808 (United States)

    2002-07-01

    The US Department of Energy (DOE) has for many years had a program for receipt and disposition of spent nuclear fuels of US origin from research reactors around the world. The research reactor spent nuclear fuel that consists of aluminum alloy composition has historically been returned to the Savannah River Site (SRS) and dispositioned via chemical reprocessing. In 1995, the DOE evaluated a number of alternatives to chemical reprocessing. In 2000, the DOE selected the melt-dilute alternative as the primary disposition path and direct disposal as the backup path. The melt-dilute technology has been developed from lab-scale demonstration up through the construction of a pilot-scale facility. The pilot-scale L-Area Experimental Facility (LEF) has been constructed and is ready for operation. The LEF will be used primarily, to confirm laboratory research on zeolite media for off- gas trapping and remote operability. Favorable results from the LEF are expected to lead to final design of the production melt-dilute facility identified as the Treatment and Storage Facility (TSF). This paper will describe the melt-dilute process and provide a status of the program development. (author)

  20. Development of melt dilute technology for disposition of aluminum based spent nuclear fuel

    International Nuclear Information System (INIS)

    Swift, W.F.

    2002-01-01

    The US Department of Energy (DOE) has for many years had a program for receipt and disposition of spent nuclear fuels of US origin from research reactors around the world. The research reactor spent nuclear fuel that consists of aluminum alloy composition has historically been returned to the Savannah River Site (SRS) and dispositioned via chemical reprocessing. In 1995, the DOE evaluated a number of alternatives to chemical reprocessing. In 2000, the DOE selected the melt-dilute alternative as the primary disposition path and direct disposal as the backup path. The melt-dilute technology has been developed from lab-scale demonstration up through the construction of a pilot-scale facility. The pilot-scale L-Area Experimental Facility (LEF) has been constructed and is ready for operation. The LEF will be used primarily, to confirm laboratory research on zeolite media for off- gas trapping and remote operability. Favorable results from the LEF are expected to lead to final design of the production melt-dilute facility identified as the Treatment and Storage Facility (TSF). This paper will describe the melt-dilute process and provide a status of the program development. (author)

  1. Study on combustion characteristics of dimethyl ether under the moderate or intense low-oxygen dilution condition

    International Nuclear Information System (INIS)

    Kang, Yinhu; Lu, Tianfeng; Lu, Xiaofeng; Wang, Quanhai; Huang, Xiaomei; Peng, Shini; Yang, Dong; Ji, Xuanyu; Song, Yangfan

    2016-01-01

    Highlights: • Oxygen content in the flame base increased due to the prolonged ignition delay time. • Flow field in the furnace affected thermal/chemical structure of the flame partially. • Preheating and dilution facilitated moderate or intense low-oxygen dilution regime. • Dominant pollutant formation ways of dimethyl ether in hot dilution were clarified. • Preheating and dilution reduced nitrogen oxide emission of dimethyl ether. - Abstract: Experiments and numerical simulations were conducted in this paper to study the combustion behavior of dimethyl ether in the moderate or intense low-oxygen dilution regime, in terms of thermal/chemical structure and chemical kinetics associated with nitrogen oxide and carbon monoxide emissions. Several co-flow temperatures and oxygen concentrations were involved in the experiments to investigate their impacts on the flame behavior systematically. The results show that in the moderate or intense low-oxygen dilution regime, oxygen concentrations in the flame base slightly increased because of the prolonged ignition delay time of the reactant mixture due to oxidizer dilution, which changed the local combustion process and composition considerably. The oxidation rates of hydrocarbons were significantly depressed in the moderate or intense low-oxygen dilution regime, such that a fraction of unburned hydrocarbons at the furnace outlet were recirculated into the outer annulus of the furnace, which changed the local radial profiles of carbon monoxide, methane, and hydrogen partially. Moreover, with the increment in co-flow temperature or oxygen mole fraction, flame temperature, and hydroxyl radical, carbon monoxide, and hydrogen mole fractions across the reaction zone increased gradually. For the dimethyl ether-moderate or intense low-oxygen dilution flame, temperature homogeneity was improved at higher co-flow temperature or lower oxygen mole fraction. The carbon monoxide emission depended on the levels of temperature and

  2. Use of gradient dilution to flag and overcome matrix interferences in axial-viewing inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Cheung, Yan; Schwartz, Andrew J.; Hieftje, Gary M.

    2014-01-01

    Despite the undisputed power of inductively coupled plasma-atomic emission spectrometry (ICP-AES), its users still face serious challenges in obtaining accurate analytical results. Matrix interference is perhaps the most important challenge. Dilution of a matrix-containing sample is a common practice to reduce matrix interference. However, determining the optimal dilution factor requires tedious and time-consuming offline sample preparation, since emission lines and the effect of matrix interferences are affected differently by the dilution. The current study exploits this difference by employing a high-performance liquid chromatography gradient pump prior to the nebulizer to perform on-line mixing of a sample solution and diluent. Linear gradient dilution is performed on both the calibration standard and the matrix-containing sample. By ratioing the signals from two emission lines (from the same or different elements) as a function of dilution factor, the analyst can not only identify the presence of a matrix interference, but also determine the optimal dilution factor needed to overcome the interference. A ratio that does not change with dilution signals the absence of a matrix interference, whereas a changing ratio indicates the presence of an interference. The point on the dilution profile where the ratio stabilizes indicates the optimal dilution factor to correct the interference. The current study was performed on axial-viewing ICP-AES with o-xylene as the solvent

  3. Comparative determination of sucrose content in sugar beet by polarimetric and isotope dilution methods

    Energy Technology Data Exchange (ETDEWEB)

    Malec, K; Szuchnik, A [Institute of Nuclear Research, Warsaw (Poland); Rydel, S; Walerianaczyk, E [Instytut Przemyslu Cukrowniczego, Warsaw (Poland)

    1976-01-01

    The comparative determination of sucrose content in sugar beets has been investigated by following methods: polarimetric, direct isotope dilution and double carrier-isotope dilution analysis. Basing upon the obtained results it has been ascertained, that in the case of worse quality beets the polarimetric determinations differ greatly from isotopic data.

  4. Analysis of several hazardous conditions for large transfer and back-dilution sequences in Tank 241-SY-101

    International Nuclear Information System (INIS)

    CW Stewart; LA Mahoney; WB Barton

    2000-01-01

    The first transfer of 89 kgal of waste and back-dilution of 61 kgal of water in Hanford Tank 241-SY-101 was accomplished December 18--20, 1999. Limits were placed on the transfer and back-dilution volumes because of concerns about potential gas release, crust sinking, and degradation of mixer pump performance. Additional transfers and back-dilutions are being planned that will bring the total to 500 kgal, which should dissolve a large fraction of the solids in the tank and dilute it well beyond the point where significant gas retention can occur. This report provides the technical bases for removing the limits on transfer and back-dilution volume by evaluating the potential consequences of several postulated hazardous conditions in view of the results of the first campaign and results of additional analyses of waste behavior

  5. Analysis of several hazardous conditions for large transfer and back-dilution sequences in Tank 241-SY-101

    Energy Technology Data Exchange (ETDEWEB)

    CW Stewart; LA Mahoney; WB Barton

    2000-01-28

    The first transfer of 89 kgal of waste and back-dilution of 61 kgal of water in Hanford Tank 241-SY-101 was accomplished December 18--20, 1999. Limits were placed on the transfer and back-dilution volumes because of concerns about potential gas release, crust sinking, and degradation of mixer pump performance. Additional transfers and back-dilutions are being planned that will bring the total to 500 kgal, which should dissolve a large fraction of the solids in the tank and dilute it well beyond the point where significant gas retention can occur. This report provides the technical bases for removing the limits on transfer and back-dilution volume by evaluating the potential consequences of several postulated hazardous conditions in view of the results of the first campaign and results of additional analyses of waste behavior.

  6. Flow characterization and dilution effects of N2 and CO2 on premixed CH4/air flames in a swirl-stabilized combustor

    International Nuclear Information System (INIS)

    Han Yue; Cai Guo-Biao; Wang Hai-Xing; Bruno Renou; Abdelkrim Boukhalfa

    2014-01-01

    Numerically-aided experimental studies are conducted on a swirl-stabilized combustor to investigate the dilution effects on flame stability, flame structure, and pollutant emissions of premixed CH 4 /air flames. Our goal is to provide a systematic assessment on combustion characteristics in diluted regimes for its application to environmentally-friendly approaches such as biogas combustion and exhaust-gas recirculation technology. Two main diluting species, N 2 and CO 2 , are tested at various dilution rates. The results obtained by means of optical diagnostics show that five main flame regimes can be observed for N 2 -diluted flames by changing excess air and dilution rate. CO 2 -diluted flames follow the same pattern evolution except that all the domains are shifted to lower excess air. Both N 2 and CO 2 dilution affect the lean blowout (LBO) limits negatively. This behavior can be counter-balanced by reactant preheating which is able to broaden the flammability domain of the diluted flames. Flame reactivity is degraded by increasing dilution rate. Meanwhile, flames are thickened in the presence of both diluting species. NO x emissions are significantly reduced with dilution and proved to be relevant to flame stability diagrams: slight augmentation in NO x emission profiles is related to transitional flame states where instability occurs. Although dilution results in increase in CO emissions at certain levels, optimal dilution rates can still be proposed to achieve an ideal compromise

  7. Sibship Size and Gendered Resource Dilution in Different Societal Contexts.

    Directory of Open Access Journals (Sweden)

    Matthijs Kalmijn

    Full Text Available Resource dilution theory hypothesizes that children's educational attainment suffers from being raised with many siblings, as the parental resources have to be shared with more children. Based on economic and cultural theories, we hypothesize that resource dilution is gendered: especially a larger number of brothers is harmful to a person's educational attainment. Using the Survey of Health, Ageing and Retirement in Europe, covering 18 European countries, we show that the number of brothers is more negatively related with the odds of obtaining a college degree than the number of sisters. This holds particularly for women. However, this pattern is weaker in countries that are known to have a more gender-egalitarian climate.

  8. Creatine Supplementation Increases Total Body Water in Soccer Players: a Deuterium Oxide Dilution Study.

    Science.gov (United States)

    Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E

    2016-02-01

    This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.

  9. SPANISH MULTICENTRIC STUDY ABOUT NUTRITION-INFLAMATIONhn WITH MID DILUTION (ENIMID STUDY: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    Barril G

    2012-06-01

    CONCLUSIONS: 1-The preliminary results show that MidDilution provides a good removal of small and middle molecules, increases appetite by providing a proper balance of cytokines through stimulation of antiinflamatory ones and neuropeptide Y. 2-It provides an improvement of body composition. Finally MidDilution improves nutritional parameters which leads to a better quality of life, as well as physical and mental status.

  10. Regional lung deposition of aged and diluted sidestream tobacco smoke

    International Nuclear Information System (INIS)

    Hofmann, W; Winkler-Heil, R; McAughey, J

    2009-01-01

    Since aged and diluted smoke particles are in general smaller and more stable than mainstream tobacco smoke, it should be possible to model their deposition on the basis of their measured particle diameters. However in practice, measured deposition values are consistently greater than those predicted by deposition models. Thus the primary objective of this study was to compare theoretical predictions obtained by the Monte Carlo code IDEAL with two human deposition studies to attempt to reconcile these differences. In the first study, male and female volunteers inhaled aged and diluted sidestream tobacco smoke at two steady-state concentrations under normal tidal breathing conditions. In the second study, male volunteers inhaled aged and diluted sidestream smoke labelled with 212 Pb to fixed inhalation patterns. Median particle diameters in the two studies were 125 nm (CMD) and 210 nm (AMD), respectively. Experimental data on total deposition were consistently higher than the corresponding theoretical predictions, exhibiting significant inter-subject variations. However, measured and calculated regional deposition data are quite similar to each other, except for the extra-thoracic region. This discrepancy suggests that either the initial particle diameter decreases upon inspiration and/or additional deposition mechanisms are operating in the case of tobacco smoke particles.

  11. Cytotoxic effects of ultra-diluted remedies on breast cancer cells.

    Science.gov (United States)

    Frenkel, Moshe; Mishra, Bal Mukund; Sen, Subrata; Yang, Peiying; Pawlus, Alison; Vence, Luis; Leblanc, Aimee; Cohen, Lorenzo; Banerji, Pratip; Banerji, Prasanta

    2010-02-01

    The use of ultra-diluted natural products in the management of disease and treatment of cancer has generated a lot of interest and controversy. We conducted an in vitro study to determine if products prescribed by a clinic in India have any effect on breast cancer cell lines. We studied four ultra-diluted remedies (Carcinosin, Phytolacca, Conium and Thuja) against two human breast adenocarcinoma cell lines (MCF-7 and MDA-MB-231) and a cell line derived from immortalized normal human mammary epithelial cells (HMLE). The remedies exerted preferential cytotoxic effects against the two breast cancer cell lines, causing cell cycle delay/arrest and apoptosis. These effects were accompanied by altered expression of the cell cycle regulatory proteins, including downregulation of phosphorylated Rb and upregulation of the CDK inhibitor p27, which were likely responsible for the cell cycle delay/arrest as well as induction of the apoptotic cascade that manifested in the activation of caspase 7 and cleavage of PARP in the treated cells. The findings demonstrate biological activity of these natural products when presented at ultra-diluted doses. Further in-depth studies with additional cell lines and animal models are warranted to explore the clinical applicability of these agents.

  12. Detection of fecal residue on poultry carcasses by laser induced fluorescence imaging techniques

    Science.gov (United States)

    The potential use of laser-induced fluorescence imaging techniques was investigated for the detection of diluted fecal matters from various parts of the digestive tract, including colon, ceca, small intestine, and duodenum, on poultry carcasses. One of the challenges for using fluorescence imaging f...

  13. Optimisation of Dilute Sulphuric Acid Hydrolysis of Waste ...

    African Journals Online (AJOL)

    Dilute sulphuric acid hydrolysis of waste paper was investigated in this study. The effects of acid concentration, time, temperature and liquid to solid ratio on the total reducing sugar concentration were studied over three levels using a four variable Box-Behnken design (BBD). A statistical model was developed for the ...

  14. Response to Comment on "Dilution limits dissolved organic carbon utilization in the deep ocean"

    KAUST Repository

    Arrieta, Jesus

    2015-12-18

    Our recent finding that dilution limits dissolved organic carbon (DOC) utilization in the deep ocean has been criticized based on the common misconception that lability equates to rapid and complete utilization. Even when considering the redefinition of recalcitrant DOC recently proposed by Jiao et al., the dilution hypothesis best explains our experimental observations.

  15. ''Over the horizon'' SANS: Measurements on near-surface Poiseuille shear-induced ordering of dilute solutions of threadlike micelles

    International Nuclear Information System (INIS)

    Hamilton, W.A.; Butler, P.D.; Hayter, J.B.; Magid, L.J.; Kreke, P.J.

    1995-01-01

    Although the behavior of a fluid under shear near a surface can be expected to be critically important to its drag and lubrication properties, most shear measurements to date have been of the bulk. This paper outlines the use of a specially developed Poiseuille shear cell at grazing incidence to measure the small-angle neutron scattering (SANS) signal from the first few tens of microns in the interfacial region. The authors illustrate the technique with measurements made on the near-surface ordering in flow past a quartz surface of dilute surfactant solutions comprising highly extended self-assembling ''threadlike'' micelles

  16. Novel understanding of calcium silicate hydrate from dilute hydration

    KAUST Repository

    Zhang, Lina; Yamauchi, Kazuo; Li, Zongjin; Zhang, Xixiang; Ma, Hongyan; Ge, Shenguang

    2017-01-01

    The perspective of calcium silicate hydrate (C-S-H) is still confronting various debates due to its intrinsic complicated structure and properties after decades of studies. In this study, hydration at dilute suspension of w/s equaling to 10

  17. Estimation of the volatility distribution of organic aerosol combining thermodenuder and isothermal dilution measurements

    Directory of Open Access Journals (Sweden)

    E. E. Louvaris

    2017-10-01

    Full Text Available A method is developed following the work of Grieshop et al. (2009 for the determination of the organic aerosol (OA volatility distribution combining thermodenuder (TD and isothermal dilution measurements. The approach was tested in experiments that were conducted in a smog chamber using organic aerosol (OA produced during meat charbroiling. A TD was operated at temperatures ranging from 25 to 250 °C with a 14 s centerline residence time coupled to a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS and a scanning mobility particle sizer (SMPS. In parallel, a dilution chamber filled with clean air was used to dilute isothermally the aerosol of the larger chamber by approximately a factor of 10. The OA mass fraction remaining was measured as a function of temperature in the TD and as a function of time in the isothermal dilution chamber. These two sets of measurements were used together to estimate the volatility distribution of the OA and its effective vaporization enthalpy and accommodation coefficient. In the isothermal dilution experiments approximately 20 % of the OA evaporated within 15 min. Almost all the OA evaporated in the TD at approximately 200 °C. The resulting volatility distributions suggested that around 60–75 % of the cooking OA (COA at concentrations around 500 µg m−3 consisted of low-volatility organic compounds (LVOCs, 20–30 % of semivolatile organic compounds (SVOCs, and around 10 % of intermediate-volatility organic compounds (IVOCs. The estimated effective vaporization enthalpy of COA was 100 ± 20 kJ mol−1 and the effective accommodation coefficient was 0.06–0.07. Addition of the dilution measurements to the TD data results in a lower uncertainty of the estimated vaporization enthalpy as well as the SVOC content of the OA.

  18. Estimation of the volatility distribution of organic aerosol combining thermodenuder and isothermal dilution measurements

    Science.gov (United States)

    Louvaris, Evangelos E.; Karnezi, Eleni; Kostenidou, Evangelia; Kaltsonoudis, Christos; Pandis, Spyros N.

    2017-10-01

    A method is developed following the work of Grieshop et al. (2009) for the determination of the organic aerosol (OA) volatility distribution combining thermodenuder (TD) and isothermal dilution measurements. The approach was tested in experiments that were conducted in a smog chamber using organic aerosol (OA) produced during meat charbroiling. A TD was operated at temperatures ranging from 25 to 250 °C with a 14 s centerline residence time coupled to a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) and a scanning mobility particle sizer (SMPS). In parallel, a dilution chamber filled with clean air was used to dilute isothermally the aerosol of the larger chamber by approximately a factor of 10. The OA mass fraction remaining was measured as a function of temperature in the TD and as a function of time in the isothermal dilution chamber. These two sets of measurements were used together to estimate the volatility distribution of the OA and its effective vaporization enthalpy and accommodation coefficient. In the isothermal dilution experiments approximately 20 % of the OA evaporated within 15 min. Almost all the OA evaporated in the TD at approximately 200 °C. The resulting volatility distributions suggested that around 60-75 % of the cooking OA (COA) at concentrations around 500 µg m-3 consisted of low-volatility organic compounds (LVOCs), 20-30 % of semivolatile organic compounds (SVOCs), and around 10 % of intermediate-volatility organic compounds (IVOCs). The estimated effective vaporization enthalpy of COA was 100 ± 20 kJ mol-1 and the effective accommodation coefficient was 0.06-0.07. Addition of the dilution measurements to the TD data results in a lower uncertainty of the estimated vaporization enthalpy as well as the SVOC content of the OA.

  19. STAR POLYMERS IN GOOD SOLVENTS FROM DILUTE TO CONCENTRATED REGIMES: CROSSOVER APPROACH

    Directory of Open Access Journals (Sweden)

    S.B.Kiselev

    2002-01-01

    Full Text Available An introduction is given to the crossover theory of the conformational and thermodynamic properties of star polymers in good solvents. The crossover theory is tested against Monte Carlo simulation data for the structure and thermodynamics of model star polymers. In good solvent conditions, star polymers approach a "universal" limit as N → ∞, however, there are two types of approach towards this limit. In the dilute regime, a critical degree of polymerization N* is found to play a similar role as the Ginzburg number in the crossover theory for critical phenomena in simple fluids. A rescaled penetration function is found to control the free energy of star polymer solutions in the dilute and semidilute regions. This equation of state captures the scaling behaviour of polymer solutions in the dilute/semidilute regimes and also performs well in the concentrated regimes, where the details of the monomer-monomer interactions become important.

  20. A NOVEL INTERPRETATION OF CONCENTRATION DEPENDENCE OF VISCOSITY OF DILUTE POLYMER SOLUTION

    Institute of Scientific and Technical Information of China (English)

    Yan Pan; Rong-shi Cheng

    2000-01-01

    The concentration dependence of the reduced viscosity of dilute polymer solution is interpreted in the light of a new concept of the self-association of polymer chains in dilute solution. The apparent self-association constant is defined as the molar association constant divided by the molar mass of individual polymer chain and is numerically interconvertible with the Huggins coefficient. The molar association constant is directly proportional to the effective hydrodynamic volume of the polymer chain in solution and is irrespective of the chain architecture. The effective hydrodynamic volume accounts for the non-spherical conformation of a short polymer chain in solution and is a product of a shape factor and hydrodynamic volume. The observed enhancement of Huggins coefficient for short chain and branched polymer is satisfactorily interpreted by the concept of self-association. The concept of self-association allows us to predict the existence of a boundary concentration Cs (dynamic contact concentration) which divides the dilute polymer solution into two regions.

  1. Theoretical Models for the Cooling Power and Base Temperature of Dilution Refrigerators

    CERN Document Server

    Wikus, Patrick

    2010-01-01

    He-3/He-4 dilution refrigerators are widely used for applications requiring continuous cooling at temperatures below approximately 300 mK. Despite of the popularity of these devices in low temperature physics, the thermodynamic relations underlying the cooling mechanism of He-3/He-4 refrigerators are very often incorrectly used. Several thermodynamic models of dilution refrigeration have been published in the past, sometimes contradicting each other. These models are reviewed and compared with each other over a range of different He-3 flow rates. In addition, a new numerical method for the calculation of a dilution refrigerator's cooling power at arbitrary flow rates is presented. This method has been developed at CERN's Central Cryogenic Laboratory. It can be extended to include many effects that cannot easily be accounted for by any of the other models, including the degradation of heat exchanger performance due to the limited number of step heat exchanger elements, which can be considerable for some design...

  2. Calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid

    International Nuclear Information System (INIS)

    Kurbanov, A.R.; Sharipov, D.Sh.

    1993-01-01

    Present article is devoted to calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid. The calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid was carried out in order to determine the thermal effects of reactions. The results of interaction of Ba(OH) 4 ·8H 2 O with 5, 10, and 20% solution of hydrofluoric acid were considered.

  3. A user-friendly robotic sample preparation program for fully automated biological sample pipetting and dilution to benefit the regulated bioanalysis.

    Science.gov (United States)

    Jiang, Hao; Ouyang, Zheng; Zeng, Jianing; Yuan, Long; Zheng, Naiyu; Jemal, Mohammed; Arnold, Mark E

    2012-06-01

    Biological sample dilution is a rate-limiting step in bioanalytical sample preparation when the concentrations of samples are beyond standard curve ranges, especially when multiple dilution factors are needed in an analytical run. We have developed and validated a Microsoft Excel-based robotic sample preparation program (RSPP) that automatically transforms Watson worklist sample information (identification, sequence and dilution factor) to comma-separated value (CSV) files. The Freedom EVO liquid handler software imports and transforms the CSV files to executable worklists (.gwl files), allowing the robot to perform sample dilutions at variable dilution factors. The dynamic dilution range is 1- to 1000-fold and divided into three dilution steps: 1- to 10-, 11- to 100-, and 101- to 1000-fold. The whole process, including pipetting samples, diluting samples, and adding internal standard(s), is accomplished within 1 h for two racks of samples (96 samples/rack). This platform also supports online sample extraction (liquid-liquid extraction, solid-phase extraction, protein precipitation, etc.) using 96 multichannel arms. This fully automated and validated sample dilution and preparation process has been applied to several drug development programs. The results demonstrate that application of the RSPP for fully automated sample processing is efficient and rugged. The RSPP not only saved more than 50% of the time in sample pipetting and dilution but also reduced human errors. The generated bioanalytical data are accurate and precise; therefore, this application can be used in regulated bioanalysis.

  4. Dilution effects on ultrafine particle emissions from Euro 5 and Euro 6 diesel and gasoline vehicles

    Science.gov (United States)

    Louis, Cédric; Liu, Yao; Martinet, Simon; D'Anna, Barbara; Valiente, Alvaro Martinez; Boreave, Antoinette; R'Mili, Badr; Tassel, Patrick; Perret, Pascal; André, Michel

    2017-11-01

    Dilution and temperature used during sampling of vehicle exhaust can modify particle number concentration and size distribution. Two experiments were performed on a chassis dynamometer to assess exhaust dilution and temperature on particle number and particle size distribution for Euro 5 and Euro 6 vehicles. In the first experiment, the effects of dilution (ratio from 8 to 4 000) and temperature (ranging from 50 °C to 150 °C) on particle quantification were investigated directly from tailpipe for a diesel and a gasoline Euro 5 vehicles. In the second experiment, particle emissions from Euro 6 diesel and gasoline vehicles directly sampled from the tailpipe were compared to the constant volume sampling (CVS) measurements under similar sampling conditions. Low primary dilutions (3-5) induced an increase in particle number concentration by a factor of 2 compared to high primary dilutions (12-20). Low dilution temperatures (50 °C) induced 1.4-3 times higher particle number concentration than high dilution temperatures (150 °C). For the Euro 6 gasoline vehicle with direct injection, constant volume sampling (CVS) particle number concentrations were higher than after the tailpipe by a factor of 6, 80 and 22 for Artemis urban, road and motorway, respectively. For the same vehicle, particle size distribution measured after the tailpipe was centred on 10 nm, and particles were smaller than the ones measured after CVS that was centred between 50 nm and 70 nm. The high particle concentration (≈106 #/cm3) and the growth of diameter, measured in the CVS, highlighted aerosol transformations, such as nucleation, condensation and coagulation occurring in the sampling system and this might have biased the particle measurements.

  5. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  6. A theoretical framework for modeling dilution enhancement of non-reactive solutes in heterogeneous porous media.

    Science.gov (United States)

    de Barros, F P J; Fiori, A; Boso, F; Bellin, A

    2015-01-01

    Spatial heterogeneity of the hydraulic properties of geological porous formations leads to erratically shaped solute clouds, thus increasing the edge area of the solute body and augmenting the dilution rate. In this study, we provide a theoretical framework to quantify dilution of a non-reactive solute within a steady state flow as affected by the spatial variability of the hydraulic conductivity. Embracing the Lagrangian concentration framework, we obtain explicit semi-analytical expressions for the dilution index as a function of the structural parameters of the random hydraulic conductivity field, under the assumptions of uniform-in-the-average flow, small injection source and weak-to-mild heterogeneity. Results show how the dilution enhancement of the solute cloud is strongly dependent on both the statistical anisotropy ratio and the heterogeneity level of the porous medium. The explicit semi-analytical solution also captures the temporal evolution of the dilution rate; for the early- and late-time limits, the proposed solution recovers previous results from the literature, while at intermediate times it reflects the increasing interplay between large-scale advection and local-scale dispersion. The performance of the theoretical framework is verified with high resolution numerical results and successfully tested against the Cape Cod field data. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Entropy production by Q-ball decay for diluting long-lived charged particles

    International Nuclear Information System (INIS)

    Kasuya, S.

    2007-09-01

    The cosmic abundance of a long-lived charged particle such as a stau is tightly constrained by the catalyzed big bang nucleosynthesis. One of the ways to evade the constraints is to dilute those particles by a huge entropy production. We evaluate the dilution factor in a case that non-relativistic matter dominates the energy density of the universe and decays with large entropy production. We find that large Q balls can do the job, which is naturally produced in the gauge-mediated supersymmetry breaking scenario. (orig.)

  8. Dynamical Properties of a Diluted Dipolar-Interaction Heisenberg Spin Glass

    International Nuclear Information System (INIS)

    Zhang Kai-Cheng; Liu Yong; Chi Feng

    2014-01-01

    Up to now the chirality is seldom studied in the diluted spin glass although many investigations have been performed on the site-ordered Edwards—Anderson model. By simulation, we investigate the dynamical properties of both the spin-glass and the chiral-glass phases in a diluted dipolar system, which was manifested to have a spin-glass transition by recent numerical study. By scaling we find that both phases have the same aging behavior and closer aging parameter μ. Similarly, the domains grow in the same way and both phases have a closer barrier exponent Ψ. It means that both the spins and the chirality have the same dynamical properties and they may freeze at the same temperature. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Validation of the L.A.L. technique (gel cloth) in radiodiagnosis and radioisotopes

    International Nuclear Information System (INIS)

    Morote, M.; Otero, M.; Chavez, G.

    1999-01-01

    Based on the validation of the LAL technique (gel cloth), real endotoxin limits (EL), expressed in endotoxin units per milliliter (EU/mL), as well as maximum dilution volume (MDV) were determined in seven radiodiagnosis agents (RDA): medronate, pentetate, sulfur colloid, albumin macroaggregated, succimer, disofenin, and pyrophosphates, which showed M.D.V. values of: 1:80; 1:16; 1:128; 1:64; 1:4; 1:128; 1:64 and EL of 20 EU/mL; 4 EU/mL; 32 EU/mL; 16 EU/mL; 1 EU/mL and 16 EU/mL, respectively. Radioisotope Tc-99m presents a MDV of 1:1 and an EL below 0,25 EU/mL. Clear interference in the acidity of sulfur colloid (pH below 2) was also found against pyrotell reaction, even in the sixth dilution of the product. M.D.V. results also showed that dilutions are even 100 times smaller than the theoretical values

  10. Large-deviation theory for diluted Wishart random matrices

    Science.gov (United States)

    Castillo, Isaac Pérez; Metz, Fernando L.

    2018-03-01

    Wishart random matrices with a sparse or diluted structure are ubiquitous in the processing of large datasets, with applications in physics, biology, and economy. In this work, we develop a theory for the eigenvalue fluctuations of diluted Wishart random matrices based on the replica approach of disordered systems. We derive an analytical expression for the cumulant generating function of the number of eigenvalues IN(x ) smaller than x ∈R+ , from which all cumulants of IN(x ) and the rate function Ψx(k ) controlling its large-deviation probability Prob[IN(x ) =k N ] ≍e-N Ψx(k ) follow. Explicit results for the mean value and the variance of IN(x ) , its rate function, and its third cumulant are discussed and thoroughly compared to numerical diagonalization, showing very good agreement. The present work establishes the theoretical framework put forward in a recent letter [Phys. Rev. Lett. 117, 104101 (2016), 10.1103/PhysRevLett.117.104101] as an exact and compelling approach to deal with eigenvalue fluctuations of sparse random matrices.

  11. Quantitation of Rotundone in Grapefruit (Citrus paradisi) Peel and Juice by Stable Isotope Dilution Assay.

    Science.gov (United States)

    Nakanishi, Akira; Fukushima, Yusuke; Miyazawa, Norio; Yoshikawa, Keisuke; Maeda, Tomoko; Kurobayashi, Yoshiko

    2017-06-21

    Aroma extract dilution analyses of the aromas of peels and juices of white and pink grapefruits revealed that rotundone, responsible for peppery, spicy, and woody odors, was detected for the first time at high flavor dilution factors of 256-1024. In both juices, rotundone was detected at the highest flavor dilution factor of 1024. Rotundone in grapefruits was quantitated by a stable isotope dilution assay with a newly synthesized deuterium-labeled internal standard, rotundone-d 2,3 : its levels were 2180 and 1920 ng/kg in white and pink grapefruit peels and 29.6 and 49.8 ng/kg in white and pink grapefruit juices, respectively. On the basis of these results, sensory analysis was performed to assess the effects of rotundone on a white grapefruit juice aroma reconstitute. This sensory analysis revealed that rotundone does not impart a woody odor or affect any of the existing attributes, but increases various attributes, thus confirming that rotundone is indispensable for the aroma of grapefruit juice.

  12. Laminar Flame Velocity and Temperature Exponent of Diluted DME-Air Mixture

    Science.gov (United States)

    Naseer Mohammed, Abdul; Anwar, Muzammil; Juhany, Khalid A.; Mohammad, Akram

    2017-03-01

    In this paper, the laminar flame velocity and temperature exponent diluted dimethyl ether (DME) air mixtures are reported. Laminar premixed mixture of DME-air with volumetric dilutions of carbon dioxides (CO2) and nitrogen (N2) are considered. Experiments were conducted using a preheated mesoscale high aspect-ratio diverging channel with inlet dimensions of 25 mm × 2 mm. In this method, flame velocities are extracted from planar flames that were stabilized near adiabatic conditions inside the channel. The flame velocities are then plotted against the ratio of mixture temperature and the initial reference temperature. A non-linear power law regression is observed suitable. This regression analysis gives the laminar flame velocity at the initial reference temperature and temperature exponent. Decrease in the laminar flame velocity and increase in temperature exponent is observed for CO2 and N2 diluted mixtures. The addition of CO2 has profound influence when compared to N2 addition on both flame velocity and temperature exponent. Numerical prediction of the similar mixture using a detailed reaction mechanism is obtained. The computational mechanism predicts higher magnitudes for laminar flame velocity and smaller magnitudes of temperature exponent compared to experimental data.

  13. Deuterium dilution method for determining the Breast milk intake of babies

    International Nuclear Information System (INIS)

    Roohi, S.; Bilal, R.; Latif, Z.

    2000-11-01

    Various methods for measuring the milk intake of breast fed babies are available. Most methods are time consuming, cumbersome and inaccurate. The report describes various methods used for Breast Milk intake measurement with emphasis on the D/sub 2/O dilution method. The methodology of the D/sub 2/O dilution method is now streamlined in this Inst. for measuring the milk intake of babies. Advantages and disadvantages of all the methods used to determine the breast milk intake of the infants are also included in the present report. For the D/sub 2/O dilution method, and oral administration of small dose of deuterium oxide (sup 2/H/sup 2/O) is given to the mothers after collecting pre-dose samples. The post dose samples of urine from the baby and saliva from the mother are collected at 24 hours intervals over a 14 days period. These samples are analyzed on isotope ratio Mass spectrometer. The D/H values obtained over a 14 days period are then extrapolated to calculate the milk intake of babies using the Microsoft Excel Computer programme designed for this purpose. (author)

  14. A beam-based alignment technique for correction of accelerator structure misalignments

    International Nuclear Information System (INIS)

    Kubo, K.; Raubenheimer, T.O.

    1994-08-01

    This paper describes a method of reducing the transverse emittance dilution in linear colliders due to transverse wakefields arising-from misaligned accelerator structures. The technique is a generalization of the Wake-Free correction algorithm. The structure alignment errors are measured locally by varying the bunch charge and/or bunch length and measuring the change in the beam trajectory. The misalignments can then be corrected by varying the beam trajectory or moving structures. The results of simulations are presented demonstrating the viability of the technique

  15. Properties of magnetically diluted nanocrystals prepared by mechanochemical route

    International Nuclear Information System (INIS)

    Balaz, P.; Skorvanek, I.; Fabian, M.; Kovac, J.; Steinbach, F.; Feldhoff, A.; Sepelak, V.; Jiang, J.; Satka, A.; Kovac, J.

    2010-01-01

    The bulk and surface properties of magnetically diluted Cd 0.6 Mn 0.4 S nanocrystals synthesized by solid state route in a planetary mill were studied. XRD, SEM, TEM (HRTEM), low-temperature N 2 sorption, nanoparticle size distribution as well as SQUID magnetometry methods have been applied. The measurements identified the aggregates of small nanocrystals, 5-10 nm in size. The homogeneity of produced particles with well developed specific surface area (15-66 m 2 g -1 ) was documented. The transition from the paramagnetic to the spin-glass-like phase has been observed below ∼40 K. The changes in the magnetic behaviour at low temperatures seem to be correlated with the formation of the new surface area as a consequence of milling. The magnetically diluted Cd 0.6 Mn 0.4 S nanocrystals are obtained in the simple synthesis step, making the process attractive for industrial applications.

  16. Critical mass variation of 239Pu with water dilution

    International Nuclear Information System (INIS)

    Pearlstein, S.

    1996-01-01

    The critical mass of an unreflected solid sphere of 239 Pu is ∼ 10 kg. The increase in critical mass observed for small water dilutions of unreflected 239 Pu spheres is paradoxical. Introducing small amounts of water uniformly throughout the sphere increases the spherical volume containing the same amount of 239 Pu as the critical solid sphere. The increase in radius decreases the surface-to-volume ratio of the sphere, which has the effect to first order of decreasing the neutron leakage, which is proportional to the surface, relative to the fissions, which are proportional to the volume. The reduction in neutron leakage is expected to reduce the critical mass, but instead, the critical mass is observed to increase. It is discussed how changes in the fast neutron spectrum with corresponding changes in the nuclear parameters result in an increase in critical mass for small water dilutions

  17. Confluence Model or Resource Dilution Hypothesis?

    DEFF Research Database (Denmark)

    Jæger, Mads

    have a negative effect on educational attainment most studies cannot distinguish empirically between the CM and the RDH. In this paper, I use the different theoretical predictions in the CM and the RDH on the role of cognitive ability as a partial or complete mediator of the sibship size effect......Studies on family background often explain the negative effect of sibship size on educational attainment by one of two theories: the Confluence Model (CM) or the Resource Dilution Hypothesis (RDH). However, as both theories – for substantively different reasons – predict that sibship size should...

  18. Extended Le Chatelier's formula for carbon dioxide dilution effect on flammability limits.

    Science.gov (United States)

    Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki

    2006-11-02

    Carbon dioxide dilution effect on the flammability limits was measured for various flammable gases. The obtained values were analyzed using the extended Le Chatelier's formula developed in a previous study. As a result, it has been found that the flammability limits of methane, propane, propylene, methyl formate, and 1,1-difluoroethane are adequately explained by the extended Le Chatelier's formula using a common set of parameter values. Ethylene, dimethyl ether, and ammonia behave differently from these compounds. The present result is very consistent with what was obtained in the case of nitrogen dilution.

  19. Developments on drug discovery and on new therapeutics: highly diluted tinctures act as biological response modifiers.

    Science.gov (United States)

    de Oliveira, Carolina C; Abud, Ana Paula R; de Oliveira, Simone M; Guimarães, Fernando de S F; de Andrade, Lucas F; Di Bernardi, Raffaello P; Coletto, Ediely L de O; Kuczera, Diogo; Da Lozzo, Eneida J; Gonçalves, Jenifer P; Trindade, Edvaldo da S; Buchi, Dorly de F

    2011-10-26

    In the search for new therapies novel drugs and medications are being discovered, developed and tested in laboratories. Highly diluted substances are intended to enhance immune system responses resulting in reduced frequency of various diseases, and often present no risk of serious side-effects due to its low toxicity. Over the past years our research group has been investigating the action of highly diluted substances and tinctures on cells from the immune system. We have developed and tested several highly diluted tinctures and here we describe the biological activity of M1, M2, and M8 both in vitro in immune cells from mice and human, and in vivo in mice. Cytotoxicity, cytokines released and NF-κB activation were determined after in vitro treatment. Cell viability, oxidative response, lipid peroxidation, bone marrow and lymph node cells immunophenotyping were accessed after mice in vivo treatment. None of the highly diluted tinctures tested were cytotoxic to macrophages or K562. Lipopolysaccharide (LPS)-stimulated macrophages treated with all highly diluted tinctures decreased tumour necrosis factor alpha (TNF-α) release and M1, and M8 decreased IFN-γ production. M1 has decreased NF-κB activity on TNF-α stimulated reporter cell line. In vivo treatment lead to a decrease in reactive oxygen species (ROS), nitric oxide (NO) production was increased by M1, and M8, and lipid peroxidation was induced by M1, and M2. All compounds enhanced the innate immunity, but M1 also augmented acquired immunity and M2 diminished B lymphocytes, responsible to acquired immunity. Based on the results presented here, these highly diluted tinctures were shown to modulate immune responses. Even though further investigation is needed there is an indication that these highly diluted tinctures could be used as therapeutic interventions in disorders where the immune system is compromised.

  20. A Cold Cycle Dilution Refrigerator for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The cold cycle dilution refrigerator is a continuous refrigerator capable of cooling to temperatures below 100 mK that makes use of a novel thermal magnetic pump....

  1. The transition between undiluted and oligomer-diluted states of nearly monodisperse polystyrenes in extensional flow

    DEFF Research Database (Denmark)

    Huang, Qian; Rasmussen, Henrik K.

    2017-01-01

    , proposed by Rasmussen and Huang (Rheol Acta 53(3):199–208 (2014a)), predicts the extensional viscosity well for the dilutions with lower concentrations. However, for the 70 and 90% 545 kg/mole samples which represent the transition between the diluted and undiluted states, the model predictions are less...

  2. Desynchronization in diluted neural networks

    International Nuclear Information System (INIS)

    Zillmer, Ruediger; Livi, Roberto; Politi, Antonio; Torcini, Alessandro

    2006-01-01

    The dynamical behavior of a weakly diluted fully inhibitory network of pulse-coupled spiking neurons is investigated. Upon increasing the coupling strength, a transition from regular to stochasticlike regime is observed. In the weak-coupling phase, a periodic dynamics is rapidly approached, with all neurons firing with the same rate and mutually phase locked. The strong-coupling phase is characterized by an irregular pattern, even though the maximum Lyapunov exponent is negative. The paradox is solved by drawing an analogy with the phenomenon of 'stable chaos', i.e., by observing that the stochasticlike behavior is 'limited' to an exponentially long (with the system size) transient. Remarkably, the transient dynamics turns out to be stationary

  3. Water-based adhesives with tailored hydrophobic association: dilution resistance and improved setting behavior.

    Science.gov (United States)

    Dundua, Alexander; Landfester, Katharina; Taden, Andreas

    2014-11-01

    Hydrophobic association and stimuli-responsiveness is a powerful tool towards water-based adhesives with strongly improved properties, which is demonstrated based on the example of hydrophobically modified alkali-soluble latexes (HASE) with modulated association. Their rheological properties are highly tunable due to the hydrophobic domains that act as physical crosslinking sites of adjustable interaction strength. Ethanol, propanol, and butanol are used as water-soluble model additives with different hydrophobicity in order to specifically target the association sites and impact the viscoelastic properties and stimuli-responsiveness. The rheological and mechanical property response upon dilution with water can be tailored, and dilution-resistant or even dilution-thickening systems are obtained. The investigations are of high importance for water-based adhesives, as our findings provide insight into general structure-property relationships to improve their setting behavior, especially upon contact with wet substrates. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Evaluation of feeds for melt and dilute process using an analytical hierarchy process

    Energy Technology Data Exchange (ETDEWEB)

    Krupa, J.F.

    2000-03-22

    Westinghouse Savannah River Company was requested to evaluate whether nuclear materials other than aluminum-clad spent nuclear fuel should be considered for treatment to prepare them for disposal in the melt and dilute facility as part of the Treatment and Storage Facility currently projected for construction in the L-Reactor process area. The decision analysis process used to develop this analysis considered many variables and uncertainties, including repository requirements that are not yet finalized. The Analytical Hierarchy Process using a ratings methodology was used to rank potential feed candidates for disposition through the Melt and Dilute facility proposed for disposition of Savannah River Site aluminum-clad spent nuclear fuel. Because of the scoping nature of this analysis, the expert team convened for this purpose concentrated on technical feasibility and potential cost impacts associated with using melt and dilute versus the current disposition option. This report documents results of the decision analysis.

  5. Evaluation of feeds for melt and dilute process using an analytical hierarchy process

    International Nuclear Information System (INIS)

    Krupa, J.F.

    2000-01-01

    Westinghouse Savannah River Company was requested to evaluate whether nuclear materials other than aluminum-clad spent nuclear fuel should be considered for treatment to prepare them for disposal in the melt and dilute facility as part of the Treatment and Storage Facility currently projected for construction in the L-Reactor process area. The decision analysis process used to develop this analysis considered many variables and uncertainties, including repository requirements that are not yet finalized. The Analytical Hierarchy Process using a ratings methodology was used to rank potential feed candidates for disposition through the Melt and Dilute facility proposed for disposition of Savannah River Site aluminum-clad spent nuclear fuel. Because of the scoping nature of this analysis, the expert team convened for this purpose concentrated on technical feasibility and potential cost impacts associated with using melt and dilute versus the current disposition option. This report documents results of the decision analysis

  6. Investigation of Possible Maillard Reaction Between Acyclovir and Dextrose upon Dilution Prior to Parenteral Administration.

    Science.gov (United States)

    Siahi Shadbad, Mohammad Reza; Ghaderi, Faranak; Hatami, Leila; Monajjemzadeh, Farnaz

    2016-12-01

    In this study the stability of parenteral acyclovir (ACV) when diluted in dextrose (DEX) as large volume intravenous fluid preparation (LVIF) was evaluated and the possible Maillard reaction adducts were monitored in the recommended infusion time. Different physicochemical methods were used to evaluate the Maillard reaction of dextrose with ACV to track the reaction in real infusion condition. Other large volume intravenous fluids were checked regarding the diluted drug stability profile. Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), and mass data proved the reaction of glucose with dextrose. A Maillard-specific high performance liquid chromatography (HPLC) method was used to track the reaction in real infusion condition in vitro. The nucleophilic reaction occurred in diluted parenteral preparations of acyclovir in 5% dextrose solutions. The best diluent solution was also selected as sodium chloride and introduced based on drug stability and also its adsorption onto different infusion sets (PVC or non PVC) to provide an acceptable administration protocol in clinical practices. Although, the Maillard reaction was proved and successfully tracked in diluted solutions, and the level of drug loss when diluted in dextrose was reported to be between 0.27 up to 1.03% of the initial content. There was no drug adsorption to common infusion sets. The best diluent for parenteral acyclovir is sodium chloride large volume intravenous fluid.

  7. Ore loses and dilution of the ore vein no. 4 in the Zletovo mine, Republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Bogatinovski Nikola L.

    2017-01-01

    Full Text Available Zletovo mines have a tradition of exploration and exploitation of vein lead-zinc ores for almost a century. Ore losses and dilutions have always been imperative in production since traditional old methods of mining and low-productivity mineralization are used. In conditions of classical and sub-level method excavations used, the calculated ore losses in ore vein No. 4 are 13.5%, while at the level of all excavations in the Zletovo mines dilution averages at 10%. Ore dilution is also an important technical parameter and several possible variants were calculated. When analyzing the dilution that occurs during the preparation of the sub-level corridor with parameters such: different drop angle (45-60o, constant thickness of 1.47 m as the average vein thickness in the calculated ore reserves, width of the sub-level corridor of 1.57 m or to the width of the ore vein No. 4 were added 10 cm (left and right to 5 cm as much as is taken in the calculation of the planned dilution and height of 2.5 m as suggested for this mining method, it can be noticed that the planned dilution during this method of mining ranges from 26.3% to 42.3%. In conditions of use of this underground method of excavation, parameters are selected that allow for the indicated lowering of the dilution. Namely, the thickness of the ore wire would be 1.47 m, the mining width would be 1.57 m, only 10 cm (left and right up to 5cm to the thickness of the ore vein will be added, the height difference between the consecutive levels would be 7.5 m, dip angle of 45 to 60°, and with the excavation the whole ore vein would be covered in height. On the basis of these parameters, models were prepared in which the ore vein would have a different dip angle, from which the values for the planned ore dilution ranged from 6.7 to 7.8%, which is significantly lower than the average dilution in the Zletovo Mine.

  8. Soil organic matter (SOM) dynamics determined by stable isotope techniques

    International Nuclear Information System (INIS)

    Gerzabek, M. H.

    1998-09-01

    Being aware of limitations and possible bias the 13 C natural abundance technique using the different 13 C enrichments in plants with differing photosynthetic pathways in a powerful tool to quantify turnover processes, both in long-term field studies and short-term laboratory experiments. Special care is needed in choosing reference plots and the proper number of replicate samples. The combination of 13 C and 14 C measurements has a high potential for a further improvement of isotope techniques in SOM studies. Natural abundance of 15 N is less powerful with respect to quantification of SOM processes than the isotope dilution technique. However its usefulness could be distinctly improved by introducing other stable isotopes into the studies.(author)

  9. Magnetite and magnetite/silver core/shell nanoparticles with diluted magnet-like behavior

    International Nuclear Information System (INIS)

    Garza-Navarro, Marco; Torres-Castro, Alejandro; Gonzalez, Virgilio; Ortiz, Ubaldo; De la Rosa, Elder

    2010-01-01

    In the present work is reported the use of the biopolymer chitosan as template for the preparation of magnetite and magnetite/silver core/shell nanoparticles systems, following a two step procedure of magnetite nanoparticles in situ precipitation and subsequent silver ions reduction. The crystalline and morphological characteristics of both magnetite and magnetite/silver core/shell nanoparticles systems were analyzed by high resolution transmission electron microscopy (HRTEM) and nanobeam diffraction patterns (NBD). The results of these studies corroborate the core/shell morphology and the crystalline structure of the magnetite core and the silver shell. Moreover, magnetization temperature dependent, M(T), measurements show an unusual diluted magnetic behavior attributed to the dilution of the magnetic ordering in the magnetite and magnetite/silver core/shell nanoparticles systems. - Graphical abstract: Biopolymer chitosan was used as stabilization media to synthesize both magnetite and magnetite/silver core/shell nanoparticles. Results of HRTEM and NBD patterns confirm core/shell morphology of the obtained nanoparticles. It was found that the composites show diluted magnet-like behavior.

  10. Quality of potential harmonics expansion method for dilute Bose ...

    Indian Academy of Sciences (India)

    Abstract. We present and examine an approximate but ab initio many-body approach, viz., potential harmonics expansion method (PHEM), which includes two-body correla- tions for dilute Bose–Einstein condensates. Comparing the total ground state energy for three trapped interacting bosons calculated in PHEM with the ...

  11. 21 CFR 172.710 - Adjuvants for pesticide use dilutions.

    Science.gov (United States)

    2010-04-01

    ... Section 172.710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES PERMITTED FOR DIRECT ADDITION TO FOOD FOR HUMAN CONSUMPTION Other Specific Usage Additives § 172.710 Adjuvants for pesticide use dilutions. The...

  12. Color dilution alopecia in a blue Doberman pinscher crossbreed

    OpenAIRE

    Perego, Roberta; Proverbio, Daniela; Roccabianca, Paola; Spada, Eva

    2009-01-01

    A 6-year-old male, blue Doberman pinscher crossbreed was presented with coat abnormalities; in particular, flank alopecia and pruritus. Based on medical the history, clinical evidence, and histopathological examination, color dilution alopecia was diagnosed. The dog was with oral melatonin treated for 3 months without success.

  13. Color dilution alopecia in a blue Doberman pinscher crossbreed.

    Science.gov (United States)

    Perego, Roberta; Proverbio, Daniela; Roccabianca, Paola; Spada, Eva

    2009-05-01

    A 6-year-old male, blue Doberman pinscher crossbreed was presented with coat abnormalities; in particular, flank alopecia and pruritus. Based on medical the history, clinical evidence, and histopathological examination, color dilution alopecia was diagnosed. The dog was with oral melatonin treated for 3 months without success.

  14. Does the dilution effect generally occur in animal diseases?

    NARCIS (Netherlands)

    Huang, Zheng Y.X.; Yu, Yang; Langevelde, Van Frank; Boer, De Willem F.

    2017-01-01

    The dilution effect (DE) has been reported in many diseases, but its generality is still highly disputed. Most current criticisms of DE are related to animal diseases. Particularly, some critical studies argued that DE is less likely to occur in complex environments. Here our meta-analyses

  15. Process for recovery and purification of lithium from dilute sources

    International Nuclear Information System (INIS)

    Kunugita, Eiichi; Kim, Jong-Hwa; Komasawa, Isao

    1990-01-01

    A process was studied for recovery and purification of lithium from hot spring water and leachate of coal fly ash in which lithium is present at very low concentration in a mixture of high concentration of less desirable species such as alkali metals, alkaline earth metals and others. Lithium is, as a first step, adsorbed selectively by an ion-sieve type adsorbent, λ-MnO 2 , which can effect separation by adsorbing lithium alone in its intraparticle spaces while adsorbing most metals on its surface. Stagewise elutions are performed, employing two elutrients: NH 4 NO 3 and then HNO 3 solution. The concentration ratio of lithium and sodium is 1/70∼1/120 in the original feed stream, and this is upgraded to 300/1 in the pregnant elutrient. Some impurities in the pregnant elutrient is removed by a solvent extraction technique, employing a mixed extractant of a β-diketone (LIX51) and tri-n-octyl-phosphine oxide in kerosene. A lithium solution with an undetectable amount of impurities is obtained by single extraction followed by single scrubbing with dilute hydrochloric acid of carefully controlled concentration. (author)

  16. Optimization of the sample dilution for minimization of the matrix effects and achieving maximal sensitivity in XRFA

    International Nuclear Information System (INIS)

    Dimov, L.; Benova, M.

    1989-01-01

    The method of neutral medium dilution can lead to practically full leveling of the matrix but the high degree of dilution at which this effect is achieved will inevitably result in loss of sensitivity. In the XRFA of heavy elements in a light matrix the dependence of the fluorescence intensity upon concentration is characterized by gradually decreasing steepness reacting saturation (as in analysis of Pb in a Pb-concentrate). The dilution by neutral medium can shift the concentration range to a zone of greater steepness but this results in an increase of sensitivity towards the concentration in the initial (undiluted) material only to a certain degree of dilution. This work presents an optimization of the degree of dilution by neutral medium which achieves a sufficient leveling of the matrix when using different materials and also maximal sensitivity towards higher concentrations. Furthermore an original solution is found to the problem of selecting a neutral medium enabling to achieve good homogenization with various materials and particularly - with marble flour. (author)

  17. A simple approximation method for dilute Ising systems

    International Nuclear Information System (INIS)

    Saber, M.

    1996-10-01

    We describe a simple approximate method to analyze dilute Ising systems. The method takes into consideration the fluctuations of the effective field, and is based on a probability distribution of random variables which correctly accounts for all the single site kinematic relations. It is shown that the simplest approximation gives satisfactory results when compared with other methods. (author). 12 refs, 2 tabs

  18. Do VCs use inside rounds to dilute founders? Some evidence from Silicon Valley

    OpenAIRE

    Fried, Jesse M.; Broughman, Brian J.

    2012-01-01

    In the bank-borrower setting, a firm’s existing lender may exploit its positional advantage to extract rents from the firm in subsequent financings. Analogously, a startup’s existing venture capital investors (VCs) may dilute the founder through a follow-on financing from these same VCs (an “inside” round) at an artificially low valuation. Using a hand-collected dataset of Silicon Valley startup firms, we find little evidence that VCs use inside rounds to dilute founders. Instead, our finding...

  19. Fractal effects on excitations in diluted ferromagnets

    International Nuclear Information System (INIS)

    Kumar, D.

    1981-08-01

    The low energy spin-wave like excitations in diluted ferromagnets near percolation threshold are studied. For this purpose an explicit use of the fractal model for the backbone of the infinite percolating cluster due to Kirkpatrick is made. Three physical effects are identified, which cause the softening of spin-waves as the percolation point is approached. The importance of fractal effects in the calculation of density of states and the low temperature thermodynamics is pointed out. (author)

  20. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240 Section 864.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  1. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  2. Low temperature anomaly of light stimulated magnetization and heat capacity of the 1D diluted magnetic semiconductors

    Science.gov (United States)

    Geffe, Chernet Amente

    2018-03-01

    This article reports magnetization and specific heat capacity anomalies in one dimensional diluted magnetic semiconductors observed at very low temperatures. Based on quantum field theory double time temperature dependent Green function technique is employed to evaluate magnon dispersion and the time correlation function. It is understood that magnon-photon coupling and magnetic impurity concentration controls both, such that near absolute temperature magnetization is nearly zero and abruptly increase to saturation level with decreasing magnon-photon coupling strength. We also found out dropping of magnetic specific heat capacity as a result of increase in magnetic impurity concentration x, perhaps because of inter-band disorder that would suppress the enhancement of density of spin waves.

  3. Low temperature anomaly of light stimulated magnetization and heat capacity of the 1D diluted magnetic semiconductors

    Directory of Open Access Journals (Sweden)

    Chernet Amente Geffe

    2018-03-01

    Full Text Available This article reports magnetization and specific heat capacity anomalies in one dimensional diluted magnetic semiconductors observed at very low temperatures. Based on quantum field theory double time temperature dependent Green function technique is employed to evaluate magnon dispersion and the time correlation function. It is understood that magnon-photon coupling and magnetic impurity concentration controls both, such that near absolute temperature magnetization is nearly zero and abruptly increase to saturation level with decreasing magnon-photon coupling strength. We also found out dropping of magnetic specific heat capacity as a result of increase in magnetic impurity concentration x, perhaps because of inter-band disorder that would suppress the enhancement of density of spin waves.

  4. Microalgae treatment removes nutrients and reduces ecotoxicity of diluted piggery digestate.

    Science.gov (United States)

    Franchino, Marta; Tigini, Valeria; Varese, Giovanna Cristina; Mussat Sartor, Rocco; Bona, Francesca

    2016-11-01

    Liquid digestate is considered as an important by-product of anaerobic digestion of agriculture wastes. Currently, it is very often directly spread on local agricultural land. Yet recently concerns on its environmental risk of this processing has begun to rise. On the other hand, investigations on the effectiveness of microalgae for wastewater treatment have started to consider also this complex matrix. In this study, we cultured the green alga Chlorella vulgaris in diluted digestate coming from the anaerobic digestion of pig slurry and corn, with the aim to significantly reduce its toxicity and its very high nutrient concentration. For this purpose, a battery of toxicity tests composed of four acute and two chronic bioassays was applied after the alga cultivation. Results were compared with those obtained in the initial characterization of the digestate. Results show that highly diluted piggery digestate can be a suitable medium for culturing microalgae, as we obtained a high removal efficiency (>90%) for ammonia, total nitrogen and phosphate, though after a few days phosphorus limitation occurred. Toxicity was significantly reduced for all the organisms tested. Possible solutions for optimizing this approach avoiding high dilution rates are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Monte Carlo study of the pure and dilute Baxter-Wu model

    International Nuclear Information System (INIS)

    Schreiber, Nir; Adler, Joan

    2005-01-01

    We studied the pure and dilute Baxter-Wu (BW) models using the Wang-Landau (WL) sampling method to calculate the density-of-states (DOS). We first used the exact result for the DOS of the Ising model to test our code. Then we calculated the DOS of the dilute Ising model to obtain a phase diagram, in good agreement with previous studies. We calculated the energy distribution, together with its first, second and fourth moments, to give the specific heat and the energy fourth order cumulant, better known as the Binder parameter, for the pure BW model. For small samples, the energy distribution displayed a doubly peaked shape, and finite size scaling analysis showed the expected reciprocal scaling of the positions of the peaks with L. The energy distribution yielded the expected BW α = 2/3 critical exponent for the specific heat. The Binder parameter minimum appeared to scale with lattice size L with an exponent θ B equal to the specific heat exponent. Its location (temperature) showed a large correction-to-scaling term θ 1 = 0.248 ± 0.025. For the dilute BW model we found a clear crossover to a single peak in the energy distribution even for small sizes and the expected α = 0 was recovered

  6. Mixing phenomena of interest to boron dilution during small break LOCAs in PWRs

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Cheng, Z.

    1995-01-01

    This paper presents the results of a study of mixing phenomena related to boron dilution during small break loss of coolant accidents (LOCAs)in pressurized water reactors (PWRs). Boron free condensate can accumulate in the cold leg loop seals when the reactor is operating in a reflux/boiler-condenser mode. A problem may occur when subsequent change in flow conditions such as loop seal clearing or re-establishment of natural circulation flow drive the diluted water in the loop seals into the reactor core without sufficient mixing with the highly borated water in the reactor downcomer and lower plenum. The resulting low boron concentration coolant entering the core may cause a power excursion leading to fuel failure. The mixing processes associated with a slow moving stream of diluted water through the loop seal to the core are examined in this paper. Bounding calculations for boron concentration of coolant entering the core during a small break LOCA in a typical Westinghouse-designed four-loop plant are also presented

  7. Remote Handling Devices for Disposition of Enriched Uranium Reactor Fuel Using Melt-Dilute Process

    International Nuclear Information System (INIS)

    Heckendorn, F.M.

    2001-01-01

    Remote handling equipment is required to achieve the processing of highly radioactive, post reactor, fuel for the melt-dilute process, which will convert high enrichment uranium fuel elements into lower enrichment forms for subsequent disposal. The melt-dilute process combines highly radioactive enriched uranium fuel elements with deleted uranium and aluminum for inductive melting and inductive stirring steps that produce a stable aluminum/uranium ingot of low enrichment

  8. Gas-surface interactions using accommodation coefficients for a dilute and a dense gas in a micro/nano-channel : heat flux predictions using combined molecular dynamics and Monte Carlo techniques

    NARCIS (Netherlands)

    Gaastra - Nedea, S.V.; Steenhoven, van A.A.; Markvoort, A.J.; Spijker, P.; Giordano, D.

    2014-01-01

    The influence of gas-surface interactions of a dilute gas confined between two parallel walls on the heat flux predictions is investigated using a combined Monte Carlo (MC) and molecular dynamics (MD) approach. The accommodation coefficients are computed from the temperature of incident and

  9. Pollutant Dilution and Diffusion in Urban Street Canyon Neighboring Streets

    Science.gov (United States)

    Sun, Z.; Fu, Zh. M.

    2011-09-01

    In the present study we investigated the airflow patterns and air quality of a series of typical street canyon combinations, developed a mass balance model to determine the local pollutant dilution rate, and discuss the impact of upstream canyon on the air quality of downstream canyon. The results indicated that the geometrical size of upstream and downstream buildings have significant impacts on the ambient airflow patterns. The pollution distribution within the canyons varies with different building combinations and flow patterns. Within the upstream canyon, pollution always accumulates to the low building side for non-symmetrical canyon, and for symmetrical canyon high level of pollution occurs at the leeward side. The height of the middle and downstream buildings can evidently change the pollutant dispersion direction during the transport process. Within the polluted canyon, the pollutant dilution rate (PDR) also varies with different street canyon combinations. The highest PDR is observed when the upstream buildings are both low buildings no matter the height of downstream building. However, the two cases are likely to contribution pollution to the downstream canyon. The H-L-H combination is mostly against local pollution remove, while the L-H-L case is considered the best optimistic building combination with both the ability of diluting local pollution and not remarkably decreasing air quality of downstream canyon. The current work is expected instructive for city designers to optimize traffic patterns under typical existing geometry or in the development of urban geometry modification for air quality control.

  10. The Dilution Effect and Information Integration in Perceptual Decision Making.

    Science.gov (United States)

    Hotaling, Jared M; Cohen, Andrew L; Shiffrin, Richard M; Busemeyer, Jerome R

    2015-01-01

    In cognitive science there is a seeming paradox: On the one hand, studies of human judgment and decision making have repeatedly shown that people systematically violate optimal behavior when integrating information from multiple sources. On the other hand, optimal models, often Bayesian, have been successful at accounting for information integration in fields such as categorization, memory, and perception. This apparent conflict could be due, in part, to different materials and designs that lead to differences in the nature of processing. Stimuli that require controlled integration of information, such as the quantitative or linguistic information (commonly found in judgment studies), may lead to suboptimal performance. In contrast, perceptual stimuli may lend themselves to automatic processing, resulting in integration that is closer to optimal. We tested this hypothesis with an experiment in which participants categorized faces based on resemblance to a family patriarch. The amount of evidence contained in the top and bottom halves of each test face was independently manipulated. These data allow us to investigate a canonical example of sub-optimal information integration from the judgment and decision making literature, the dilution effect. Splitting the top and bottom halves of a face, a manipulation meant to encourage controlled integration of information, produced farther from optimal behavior and larger dilution effects. The Multi-component Information Accumulation model, a hybrid optimal/averaging model of information integration, successfully accounts for key accuracy, response time, and dilution effects.

  11. The Dilution Effect and Information Integration in Perceptual Decision Making.

    Directory of Open Access Journals (Sweden)

    Jared M Hotaling

    Full Text Available In cognitive science there is a seeming paradox: On the one hand, studies of human judgment and decision making have repeatedly shown that people systematically violate optimal behavior when integrating information from multiple sources. On the other hand, optimal models, often Bayesian, have been successful at accounting for information integration in fields such as categorization, memory, and perception. This apparent conflict could be due, in part, to different materials and designs that lead to differences in the nature of processing. Stimuli that require controlled integration of information, such as the quantitative or linguistic information (commonly found in judgment studies, may lead to suboptimal performance. In contrast, perceptual stimuli may lend themselves to automatic processing, resulting in integration that is closer to optimal. We tested this hypothesis with an experiment in which participants categorized faces based on resemblance to a family patriarch. The amount of evidence contained in the top and bottom halves of each test face was independently manipulated. These data allow us to investigate a canonical example of sub-optimal information integration from the judgment and decision making literature, the dilution effect. Splitting the top and bottom halves of a face, a manipulation meant to encourage controlled integration of information, produced farther from optimal behavior and larger dilution effects. The Multi-component Information Accumulation model, a hybrid optimal/averaging model of information integration, successfully accounts for key accuracy, response time, and dilution effects.

  12. Host polymer influence on dilute polystyrene segmental dynamics

    Science.gov (United States)

    Lutz, T. R.

    2005-03-01

    We have utilized deuterium NMR to investigate the segmental dynamics of dilute (2%) d3-polystyrene (PS) chains in miscible polymer blends with polybutadiene, poly(vinyl ethylene), polyisoprene, poly(vinyl methylether) and poly(methyl methacrylate). In the dilute limit, we find qualitative differences depending upon whether the host polymer has dynamics that are faster or slower than that of pure PS. In blends where PS is the fast (low Tg) component, segmental dynamics are slowed upon blending and can be fit by the Lodge-McLeish model. When PS is the slow (high Tg) component, PS segmental dynamics speed up upon blending, but cannot be fit by the Lodge-McLeish model unless a temperature dependent self-concentration is employed. These results are qualitatively consistent with a recent suggestion by Kant, Kumar and Colby (Macromolecules, 2003, 10087), based upon data at higher concentrations. Furthermore, as the slow component, we find the segmental dynamics of PS has a temperature dependence similar to that of its host. This suggests viewing the high Tg component dynamics in a miscible blend as similar to a polymer in a low molecular weight solvent.

  13. Controlling the quality of nanocrystalline silicon made by hot-wire chemical vapor deposition by using a reverse H2 profiling technique

    NARCIS (Netherlands)

    Li, H. B. T.; Franken, R.H.; Stolk, R.L.; van der Werf, C.H.M.; Rath, J.K.; Schropp, R.E.I.

    2008-01-01

    Hydrogen profiling, i.e., decreasing the H2 dilution during deposition, is a well-known technique to maintain a proper crystalline ratio of the nanocrystalline (nc-Si:H) absorber layers of plasma-enhanced chemical vapor-deposited (PECVD) thin film solar cells. With this technique a large increase in

  14. Results of Waste Transfer and Back-Dilution in Tanks 241-SY-101 and 241-SY-102

    International Nuclear Information System (INIS)

    Mahoney, L.A.; Antoniak, Z.I.; Barton, W.B.; Conner, J.M.; Kirch, N.W.; Stewart, C.W.; Wells, B.E.

    2000-01-01

    This report chronicles the process of remediation of the flammable gas hazard in Tank 241-SY-101 (SY-101) by waste transfer and back-dilution from December 18, 1999 through April 2, 2000. A brief history is given of the development of the flammable gas retention and release hazard in this tank, and the transfer and dilution systems are outlined. A detailed narrative of each of the three transfer and dilution campaigns is given to provide structure for the balance of the report. Details of the behavior of specific data are then described, including the effect of transfer and dilution on the waste levels in Tanks SY-101 and SY-102, data from strain gauges on equipment suspended from the tank dome, changes in waste configuration as inferred from neutron and gamma logs, headspace gas concentrations, waste temperatures, and the mixerpump operating performance. Operating data and performance of the transfer pump in SY-101 are also discussed

  15. Impact of dilution on the microstructure and properties of Ni-based 625 alloy coatings

    Directory of Open Access Journals (Sweden)

    Tiago Jose Antoszczyszyn

    2014-06-01

    Full Text Available Nickel-based alloy IN 625 is used to protect components of aircrafts, power generation and oil refinery due to an association of toughness and high corrosion resistance. These properties are associated with the chemical composition and microstructure of coatings which depend on the processing parameters and the composition of the component being protected. This paper assessed impact of dilution on the microstructure and properties of the Ni alloy IN 625 deposited by Plasma Transferred Arc (PTA on two substrates: carbon steel API 5L and stainless steel AISI 316L. Differences due to the interaction with the substrate were maximized analyzing single layer coatings, processed with three deposition current: 120, 150 and 180 A. Correlation with a cast Nickel-based alloy sample contributed to assess the impact of dilution on coatings. Dilution was determined by the area ratio and Vickers hardness measured on the transverse section of coatings. Scanning electron and Laser confocal microscopy and X-ray diffraction analysis were carried out to characterize the microstructure. Results indicated the increasing dilution with the deposition current was deeply influenced by the substrate. Dilution ranging from 5 to 29% was measured on coatings processed on the API 5L steel and from 22 to 51% on the low thermal conductivity AISI 316L steel substrate. Differences on the microstructure and properties of coatings can be associated with the interaction with each substrate. Higher fraction of carbides account for the higher coating hardness when processing on API 5L whereas the low thermal conductivity of AISI 316L and the higher Fe content in solid solution contributed to the lower hardness of coatings.

  16. Direct measurement of burn up monitor by Pulsed Laser Deposition (PLD) followed by Isotopic Dilution Mass Spectrometry

    International Nuclear Information System (INIS)

    Sajimol, R.; Manoravi, P.; NaIini, S.; Balasubramanian, R.; Joseph, M.

    2012-01-01

    Burn-up measurement is an important aspect in the assessment of fuel performance especially for experimental nuclear fuels. Conventional mass spectrometric technique offer the best accuracy for determination of burn-up but they suffer from the labour intensive and time consuming chemical separation procedures followed by mass spectrometric analysis. Our laboratory has reported a potential laser mass spectrometric technique with advantages of (i) direct and fast measurement of ion intensities of selected rare earth element and residual heavy element atoms to deduce burn up and (ii) adaptability to remote handling of radioactive samples. Direct quantification of burn up monitor element in fuel in the form of pellet as well as liquid was probed by pulsed laser deposition followed by Isotopic Dilution Mass Spectrometric technique (IDMS). The procedure involving laser ablation of heavy element (namely U and Pu) and fission product (Nd, La etc) from a simulated spent fuel matrix followed by isotopic dilution mass spectrometry using thermal ionization mass spectrometry (TIMS) has been presently attempted to arrive at the rare earth element to heavy element ratio to deduce burn up using the methodology described in our earlier work. The details of IDMS technique has been reviewed by Heumann et al. Accurately weighed amounts of major rare earth fission products such as Nd, La, Ce and Sm in solution form were mixed with known quantity of uranium solution (all the weights are corresponding to their fission yields and the residual heavy element atoms after a given burn up) and mixed together to attain uniformity. The solution is then dried and resulting powder was pelletized and sintered. Subsequently, the pellet was ablated with pulsed laser (8 ns, 532 nm, Nd-YAG) and the plume was deposited on a glass plate. This deposit was dissolved in minimum amount of nitric acid. A known volume of the solution was mixed with spike (for e.g., 150 Nd/ 142 Nd, 233 U/ 238 U in this study

  17. Developments on drug discovery and on new therapeutics: highly diluted tinctures act as biological response modifiers

    Directory of Open Access Journals (Sweden)

    de Oliveira Carolina C

    2011-10-01

    Full Text Available Abstract Background In the search for new therapies novel drugs and medications are being discovered, developed and tested in laboratories. Highly diluted substances are intended to enhance immune system responses resulting in reduced frequency of various diseases, and often present no risk of serious side-effects due to its low toxicity. Over the past years our research group has been investigating the action of highly diluted substances and tinctures on cells from the immune system. Methods We have developed and tested several highly diluted tinctures and here we describe the biological activity of M1, M2, and M8 both in vitro in immune cells from mice and human, and in vivo in mice. Cytotoxicity, cytokines released and NF-κB activation were determined after in vitro treatment. Cell viability, oxidative response, lipid peroxidation, bone marrow and lymph node cells immunophenotyping were accessed after mice in vivo treatment. Results None of the highly diluted tinctures tested were cytotoxic to macrophages or K562. Lipopolysaccharide (LPS-stimulated macrophages treated with all highly diluted tinctures decreased tumour necrosis factor alpha (TNF-α release and M1, and M8 decreased IFN-γ production. M1 has decreased NF-κB activity on TNF-α stimulated reporter cell line. In vivo treatment lead to a decrease in reactive oxygen species (ROS, nitric oxide (NO production was increased by M1, and M8, and lipid peroxidation was induced by M1, and M2. All compounds enhanced the innate immunity, but M1 also augmented acquired immunity and M2 diminished B lymphocytes, responsible to acquired immunity. Conclusions Based on the results presented here, these highly diluted tinctures were shown to modulate immune responses. Even though further investigation is needed there is an indication that these highly diluted tinctures could be used as therapeutic interventions in disorders where the immune system is compromised.

  18. Transverse emittance dilution due to coupler kicks in linear accelerators

    Directory of Open Access Journals (Sweden)

    Brandon Buckley

    2007-11-01

    Full Text Available One of the main concerns in the design of low emittance linear accelerators (linacs is the preservation of beam emittance. Here we discuss one possible source of emittance dilution, the coupler kick, due to transverse electromagnetic fields in the accelerating cavities of the linac caused by the power coupler geometry. In addition to emittance growth, the coupler kick also produces orbit distortions. It is common wisdom that emittance growth from coupler kicks can be strongly reduced by using two couplers per cavity mounted opposite each other or by having the couplers of successive cavities alternate from above to below the beam pipe so as to cancel each individual kick. While this is correct, including two couplers per cavity or alternating the coupler location requires large technical changes and increased cost for superconducting cryomodules where cryogenic pipes are arranged parallel to a string of several cavities. We therefore analyze consequences of alternate coupler placements. We show here that alternating the coupler location from above to below compensates the emittance growth as well as the orbit distortions. For sufficiently large Q values, alternating the coupler location from before to after the cavity leads to a cancellation of the orbit distortion but not of the emittance growth, whereas alternating the coupler location from before and above to behind and below the cavity cancels the emittance growth but not the orbit distortion. We show that cancellations hold for sufficiently large Q values. These compensations hold even when each cavity is individually detuned, e.g., by microphonics. Another effective method for reducing coupler kicks that is studied is the optimization of the phase of the coupler kick so as to minimize the effects on emittance from each coupler. This technique is independent of the coupler geometry but relies on operating on crest. A final technique studied is symmetrization of the cavity geometry in the

  19. A theory for the anisotropic interaction between two substitutional magnetic impurities and the magnetic anisotropic effect in dilute magnetic alloys

    International Nuclear Information System (INIS)

    Satter, M.A.

    1990-08-01

    In this paper, a formalism for studying the anisotropic interaction between two substitutional magnetic impurities and the magnetic anisotropic effect in a dilute noble metal- transition metal magnetic alloy has been developed from relativistic scattering theory. The theoretical development and the computational techniques of this formalism are based on relativistic spin-polarized scattering theory and relativistic band structure frameworks. For studying the magnetic anisotropic effect a convenient ''working'' frame of reference with its axes oriented along the fcc crystal axes is set up. This formalism is applied to study the situation for two Fe impurities in paramagnetic Au hosts. For AuFe dilute alloy, the two impurity site interaction as a function of separation is not oscillatory and the anisotropic effect is found to be less than the two site interaction itself only by an order of magnitude. Apart from the anisotropic coupling of the two impurity spins to the separation vector, for the first time, another weak anisotropic coupling to the crystal axes is also contained in the two site interaction. These anisotropic effects are the results of the relativistic spin-orbit interaction which are incorporated into the formalism. (author). 22 refs, 5 figs

  20. Survey of the chemical diffusion at infinite dilution in the nickel-plutonium and aluminium-uranium systems; Contribution a l'etude de l'heterodiffusion a dilution infinie systemes nickel-plutonium et aluminium-uranium

    Energy Technology Data Exchange (ETDEWEB)

    Blechet, J J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-09-01

    Solubility S{sub 0} and chemical diffusion coefficients D{sub PuNi} at infinite dilution of plutonium in nickel have been determined by autoradiography {alpha} in poly-phased system by the welded couples method: S{sub 0} varies from 40 to 80.10{sup -6} (atomic concentration) and D{sub PuNi} follows an Arrhenius law D = D{sub 0} exp (-Q/RT) with 0.03 cm{sup 2}/s < D{sub 0} < 1.6 cm{sup 2}/s and 46000 cal/mole < Q < 56000 cal/mole. Diffusion of uranium in aluminium have been carried out by fissiography using the thin layer method. Frequency factor lies between 0.01 and 3.1 cm{sup 2}/s and the activation energy lies between 24000 and 34000 cal/mole. (author) [French] La solubilite S{sub 0} et les coefficients de diffusion chimique D{sub PuNi}, a dilution infinie, du plutonium dans le nickel ont ete determines par autoradiographie {alpha} sur des couples soudes en systeme polyphase. Entre 1000 et 1125 deg. C. S{sub 0} varie de 40 a 80.10{sup -6} et D obeit a une loi d'ARRHENIUS (concentration atomique) D = D{sub 0} exp (-Q/RT) avec 0.03 cm{sup 2}s{sup -1} < D{sub 0} < 1.60 cm{sup 2}s{sup -1} 46000 calories par mole < Q < 56000 calories par mole. La diffusion de l'uranium dans l'aluminium a ete etudiee par fissiographie en utilisant la technique du depot mince. Le facteur de frequence est situe entre 0.01 et 3.1 cm{sup 2}s{sup -1} et l'energie d'activation entre 24000 et 34000 calories par mole. (auteur)

  1. Single-dilution enzyme-linked immunosorbent assay for quantification of antigen-specific salmonid antibody

    Science.gov (United States)

    Alcorn, S.W.; Pascho, R.J.

    2000-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.

  2. Diagnosis of hemoparasitosis trough the spread-smear technique using a drop of blood clot

    OpenAIRE

    Neusa Saltiél Stobbe; Eunice Leonora Chaplin; Maria das Graças de Souza Paiva; Nilton Rogério Santos Silva; Flávio A. Pacheco Araújo; Elinor Fortes

    1992-01-01

    The spread-smear technique using a drop of blood clot and stained by diluted and undimitcd Giemsa stain was evaluated for the search of blood cell types and recognition of Babesia bovis, Babesia bigemina and Anaplasma marginale hemoparasites. The blood clot samples were taken from a 6 month-old calf experimentally inoculated with the blood from a Cattle Tick Fever carrier. The Technique was sumitable for the observation of different blood cells and for the recognition of the hemoparasites.

  3. Coherence and stiffness of spin waves in diluted ferromagnets

    Czech Academy of Sciences Publication Activity Database

    Turek, Ilja; Kudrnovský, Josef; Drchal, Václav

    2016-01-01

    Roč. 94, č. 17 (2016), č. článku 174447. ISSN 2469-9950 R&D Projects: GA ČR GA15-13436S Institutional support: RVO:68081723 ; RVO:68378271 Keywords : spin wave s * diluted ferromagnets * disordered systems Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.836, year: 2016

  4. The effect of dilution on the gas-retention behavior of Tank 241-SY-101 waste

    International Nuclear Information System (INIS)

    Bredt, P.R.; Tingey, S.M.; Shade, E.H.

    1995-09-01

    The effect of dilution on gas retention in waste from Tank 241-SY-101 was investigated. A composite sample was prepared from material collected during the Window ''C'' and Window ''E'' sampling events. The composite contained material from both the convective and nonconvective layer in the proportions existing in the tank. Operation of the mixer pump in Tank 241-SY-101 has homogenized the tank material, and dilution of the current waste would require additional mixing; therefore, no attempt was made to use unhomogenized tank waste to prepare the composite. The composite was diluted with 2 M NaOH at ratios of 0.5:1, 0.75: 1, 1:1, and 3:1 per volume (2 M NaOH:tank waste)

  5. Determination of biomass of mango (Mangifera indica L.) trees by non-destructive method using principle of isotope dilution

    International Nuclear Information System (INIS)

    Kotur, S.C.; Keshava Murthy, S.V.

    2003-01-01

    Biomass of 4-year old trees alphonso mango was estimated by injecting of carrier-free 32 P into the trunk followed by radio-assay of the isotope after a complete dilution of 32 P in the tree, being 3 months after injection. The isotopically calculated plant volume (59 903-68 981 cc plant -1 ) and biomass (31.70 - 36.23 kg plant -1 ) showed good agreement but generally overestimated both by about 23% compared to the actual values determined physically (43 720-60 693 cc plant -1 and 22.88-34.78 kg plant -1 , respectively). Application of the technique in a set of another four 15-year old mango trees yielded volume estimates of 1, 70, 749-1 75 835 cc plant -1 (mean=1, 75 835±1.12%) and biomass estimates of 73.0 - 87.4 kg plant -1 (mean=80.45±6.8%). The technique is of promise in fertilizer use efficiency and nutrient dynamics studies in tree crops. (author)

  6. Contribution to the scintillation detection optimization in double phase detectors for direct detection of dark matter

    Science.gov (United States)

    Balan, Catalin

    Na ultima decada, foram feitos grandes progressos no desenvolvimento dos detetores de detecao direta das particulas que constituem a materia negra. Com estrategias do aumento gradual do volume do alvo e, simultaneamente, de reducao dos niveis de fundo, a experiencia XENON obteve resultados muito bons e perspetivas promissoras para a detecao de materia negra. Tarefas relativas a analise de dados experimentais adquiridos com o detetor de dupla fase em uso, assim como as simulacoes do campo eletrico, desenvolvimento, montagem e testes para o proximo detetor XENON1T, assim como a participacao regular na manutencao geral e monitorizacao do prototipo atual XENON100 no LNGS, constituiram o plano de trabalhos para as atividades de investigacao do presente doutoramento e a minha contribuicao para a otimizacao da detecao de cintilacao nos detetores da experiencia XENON. A necessidade de alcancar niveis elevados de sensibilidade, requer inovacao em todos os aspetos fisicos do detetor, assim como a reducao de todas as fontes de radioatividade que contribuem para o fundo. O modo mais indicado de operacao para os detetores com enchimento a Xe no estado liquido e gasoso envolve a medicao da cintilacao primaria e da secundaria provenientes da interacao das particulas no Xe liquido. A razao entre estes dois sinais permite diferenciar claramente a maior parte dos eventos correspondentes as fundo dos eventos correspondentes a WIMPs. Deste modo, a leitura dos sinais correspondentes a cintilacao e de extrema importancia. A amplitude do sinal de cintilacao antes dos fotossensores e maximizada atraves da otimizacao de varios parametros, tais como a geometria do alvo do detetor, a transparencia das grelhas dos eletrodos, a uniformidade do ganho em cintilacao secundaria e a utilizacao de material reflectivo para cobrir as superficies que nao sao fotossensiveis.

  7. Fertility Limitation and Child Schooling in Ouagadougou: Selective Fertility or Resource Dilution?

    Science.gov (United States)

    Bougma, Moussa; LeGrand, Thomas K; Kobiané, Jean-François

    2015-06-01

    Using original data collected in Ouagadougou, Burkina Faso, this study investigates evidence for the competing theories that fertility reductions increase children's education through either the quantity-quality tradeoff (intentionally choosing smaller families to make greater investments in education and other indicators of child quality) or resource dilution (having more children reduces resources available per child, regardless of intentionality of family size). The results provide evidence for both hypotheses: children having four or fewer siblings were significantly more likely to be enrolled in school if their mothers had intentionally stopped childbearing relative to those whose mothers wanted more children but whose childbearing was limited by subfecundity. The difference between intentional and unintentional family limitation was not significant for parities greater than five. In addition, the relationship between number of siblings and their schooling is negative, regardless of the intentionality of family-size limitation, but the strength of this negative relationship is approximately twice as high among children whose mothers intentionally limited fertility (reflecting both selection and dilution effects) than among children whose mothers were subfecund (reflecting the pure dilution effect). © 2015 The Population Council, Inc.

  8. Basic research in homeopathy and ultra-high dilutions: what progress is being made?

    Science.gov (United States)

    Betti, Lucietta; Trebbi, Grazia; Olioso, Debora; Marzotto, Marta; Bellavite, Paolo

    2013-04-01

    This report summarises the latest research developments in the field of high dilutions and homeopathy, as presented at the GIRI symposium of the leading international organisation of scientists in this field, in Florence, Italy in September 2012. The scientific community's early scepticism concerning the possible biological and pharmacological activity of highly diluted solutions, is giving way to a more open-minded attitude that no longer obstructs critical and experimental investigations in this emerging field of biomedicine. Copyright © 2013. Published by Elsevier Ltd.. All rights reserved.

  9. New experiences in borehole dilution techniques

    International Nuclear Information System (INIS)

    Umesh Chandra

    1977-01-01

    A study of filtration rate and direction of groundwater flow was made at various depths in borehole using bromine-82 as groundwater tracer. The filtration rates were found to vary along the depth of borehole. Vertical flow in the borehole was observed in an alluvial aquifer even after sealing the borehole by rubber packers. The filtration rates, obtained without the packer at various depths, were much less than those obtained with packer. Microscopic hydrological information was obtained around the borehole which was useful in planning a drainage system in the area. A depth was located in the borehole where vertical flow was in opposite directions. At another depth a zone of horizontal flow was observed where vertical flow was in opposite directions. The improved instrumentation used rendered the field work extremely easy quick and readily reproducible. (author)

  10. Point defects in dilute nitride III-N-As and III-N-P

    International Nuclear Information System (INIS)

    Chen, W.M.; Buyanova, I.A.; Tu, C.W.; Yonezu, H.

    2006-01-01

    We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As Ga antisites and Ga i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides

  11. Developing of FTIR- and new probe technique for combustion gas analysis; Utveckling av FTIR- och sondteknik foer gasanalys i foerbraenningsrum

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, Annika; Andersson, Christer [Vattenfall Utveckling AB, Stockholm (Sweden); Thulin, C [Swedish National Testing and Research Inst., Boraas (Sweden); Karlsson, Maria; Aamand, L E [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1996-08-01

    The objective of the reported project has been to develop and field test a versatile measurement system for combustion gases based on the FTIR technique. The project has included the following stages: Development of gas sampling methods, Further development of the FTIR technique, Field testing of the measurement system. The development of evaluation routines based on CLS and PLS methods has lead to the conclusion that both methods are well suited for the application in question, which enables an automation of the evaluation procedure. However, the elaboration of versatile and quality controlled methods is time consuming and the application requires a qualified user. With the dilution probe prototype, a satisfactory rejection of particles is achieved at the same time as a good mixing of the dilution gas and the sample gas takes place. Sampling is performed without using a filter at the probe tip. The intended function of the probe requires that most particles can be rejected without giving rise to a too high dilution ratio. This was achieved in the middle and upper part of the CFB boiler. Comparisons of measurement data from field measurements with the developed probe concept and the `conventional` CTH extractive probe show that the results are in good agreement in many cases, but also that interesting discrepancies exist. Sampling artefacts have been noticed for the gases HCN and SO{sub 2}, where HCN and SO{sub 2} are found in higher concentrations when sampling with the dilution probe. Analyzed concentrations of CO and hydrocarbons (methane, ethene and acetylene) are throughout all the measurements lower when the dilution probe is used. 21 refs, 34 figs, 29 tabs

  12. A dynamic dilution system-based evaluation of the procedure adopted for determining ozone precursor volatile compounds.

    Science.gov (United States)

    Palluau, Fabienne; Mirabel, Philippe; Millet, Maurice

    2005-02-01

    A dynamic dilution system was created to evaluate the performance and the reliability of ozone precursor volatile organic compound (VOC) sampling ("TO-Can" canisters) and analysis (thermal desorption/gas chromatography/flame ionisation detection) techniques used by the "Laboratoire Interregional de Chimie du Grand Est (LIC)". Different atmospheres of VOCs were generated at concentrations between 0.8 and 25 ppb, with temperatures of 0, 10, 20 and 30 degrees C, and with relative humidities of 0, 30, 50, 70 and 90%. These conditions are generally representative of those commonly observed in ambient air in the eastern France. This dynamic dilution allows the simulation of a wide range of scenarios (concentrations, temperatures and relative humidities). After assessing the capacity and performance of the system, it was applied in order to evaluate the recoveries and stabilities of VOCs from canisters used for the collection and analysis of two mixtures of VOCs. The first mixture contained six alkanes (ethane, propane, butane, pentane, hexane and heptane), and the second contained five alkenes (ethene, propene, butene, 1-pentene and 1-hexene), five aromatics (benzene, toluene, ethylbenzene, m-xylene and o-xylene), acetylene, and 1,3-butadiene. No significant losses of alkanes from the canisters were observed after 21 days of storage, and good recoveries of alkanes from the canisters (>80%) were obtained regardless of the concentration, the temperature and the relative humidity. However, losses of certain aromatics were noted at low relative humidity.

  13. Bioethanol productions from rice polish by optimization of dilute acid ...

    African Journals Online (AJOL)

    Lignocellulose materials are abundant renewable resource for the production of biofuel from fermentative organism (Sacchromyces cervesiae). Rice polish is cheapest and abundant lignocelluloses resource and has potential to produce bioethanol. The main steps for the conversion of biomass into glucose required dilute ...

  14. Atomic displacements in dilute alloys of Cr, Nb and Mo

    Indian Academy of Sciences (India)

    physics pp. 497–514. Atomic displacements in dilute alloys of Cr, Nb and Mo ... used to calculate dynamical matrix and the impurity-induced forces up to second nearest ... origin, the lattice is strained, and the host atoms get displaced to new ...

  15. Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS

    International Nuclear Information System (INIS)

    Fortunato, G.; Wunderli, S.

    2003-01-01

    The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained. This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO 3 /H 2 O 2 microwave digestion. The thallium isotope amount ratio (n( 205 Tl)/n( 203 Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n( 206 Pb)/n( 208 Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study ''lead in wine'' organised by the CCQM (Comite Consultatif pour la Quantite de Matiere, BIPM, Paris; the highest measurement authority for analytical chemical measurements). The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=k x uc, k=2) The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R 206,B of the blend between the enriched spike and the sample. (orig.)

  16. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique.

    Science.gov (United States)

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-09-29

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt.

  17. Novel understanding of calcium silicate hydrate from dilute hydration

    KAUST Repository

    Zhang, Lina

    2017-05-13

    The perspective of calcium silicate hydrate (C-S-H) is still confronting various debates due to its intrinsic complicated structure and properties after decades of studies. In this study, hydration at dilute suspension of w/s equaling to 10 was conducted for tricalcium silicate (C3S) to interpret long-term hydration process and investigate the formation, structure and properties of C-S-H. Based on results from XRD, IR, SEM, NMR and so forth, loose and dense clusters of C-S-H with analogous C/S ratio were obtained along with the corresponding chemical formulae proposed as Ca5Si4O13∙6.2H2O. Crystalline structure inside C-S-H was observed by TEM, which was allocated at the foil-like proportion as well as the edge of wrinkles of the product. The long-term hydration process of C3S in dilute suspension could be sketchily described as migration of calcium hydroxide and in-situ growth of C-S-H with equilibrium silicon in aqueous solution relatively constant and calcium varied.

  18. Learning and forgetting on asymmetric, diluted neural networks

    International Nuclear Information System (INIS)

    Derrida, B.; Nadal, J.P.

    1987-01-01

    It is possible to construct diluted asymmetric models of neural networks for which the dynamics can be calculated exactly. The authors test several learning schemes, in particular, models for which the values of the synapses remain bounded and depend on the history. Our analytical results on the relative efficiencies of the various learning schemes are qualitatively similar to the corresponding ones obtained numerically on fully connected symmetric networks

  19. Competition explains limited attention and perceptual resources: implications for perceptual load and dilution theories.

    Science.gov (United States)

    Scalf, Paige E; Torralbo, Ana; Tapia, Evelina; Beck, Diane M

    2013-01-01

    Both perceptual load theory and dilution theory purport to explain when and why task-irrelevant information, or so-called distractors are processed. Central to both explanations is the notion of limited resources, although the theories differ in the precise way in which those limitations affect distractor processing. We have recently proposed a neurally plausible explanation of limited resources in which neural competition among stimuli hinders their representation in the brain. This view of limited capacity can also explain distractor processing, whereby the competitive interactions and bias imposed to resolve the competition determine the extent to which a distractor is processed. This idea is compatible with aspects of both perceptual load and dilution models of distractor processing, but also serves to highlight their differences. Here we review the evidence in favor of a biased competition view of limited resources and relate these ideas to both classic perceptual load theory and dilution theory.

  20. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  1. Comparison of bile acid synthesis determined by isotope dilution versus fecal acidic sterol output in human subjects

    International Nuclear Information System (INIS)

    Duane, W.C.; Holloway, D.E.; Hutton, S.W.; Corcoran, P.J.; Haas, N.A.

    1982-01-01

    Fecal acidic sterol output has been found to be much lower than bile acid synthesis determined by isotope dilution. Because of this confusing discrepancy, we compared these 2 measurements done simultaneously on 13 occasions in 5 normal volunteers. In contrast to previous findings, bile acid synthesis by the Lindstedt isotope dilution method averaged 16.3% lower than synthesis simultaneously determined by fecal acidic sterol output (95% confidence limit for the difference - 22.2 to -10.4%). When one-sample determinations of bile acid pools were substituted for Lindstedt pools, bile acid synthesis by isotope dilution averaged 5.6% higher than synthesis by fecal acidic sterol output (95% confidence limits -4.9 to 16.1%). These data indicate that the 2 methods yield values in reasonably close agreement with one another. If anything, fecal acidic sterol outputs are slightly higher than synthesis by isotope dilution

  2. Structural, morphological and magnetic analysis of Cd–Co–S dilute magnetic semiconductor nanofilms

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Suresh [Department of Physics and Materials Science, Jaypee University of Information Technology, Waknaghat, Solan, Himachal Pradesh 173234 (India); Negi, N.S. [Department of Physics, Himachal Pradesh University, Summer Hill, Shimla, Himachal Pradesh 171005 (India); Katyal, S.C. [Department of Physics, Jaypee Institute of Information Technology, Sec-128, Noida, Uttar Pradesh 201301 (India); Sharma, Pankaj, E-mail: pankaj.sharma@juit.ac.in [Department of Physics and Materials Science, Jaypee University of Information Technology, Waknaghat, Solan, Himachal Pradesh 173234 (India); Sharma, Vineet [Department of Physics and Materials Science, Jaypee University of Information Technology, Waknaghat, Solan, Himachal Pradesh 173234 (India)

    2014-10-01

    Cd{sub 1−x}Co{sub x}S dilute magnetic semiconductor nanofilms (0≤x≤0.08 at%) deposited by chemical bath deposition have been investigated using grazing angle x-ray diffraction, atomic force microscopy and vibrating sample magnetometer. The introduction of Co{sup 2+} ions in CdS structure induces structural disorders and hence, results in degradation of crystallinity. The crystallite size, interplanar spacing and lattice parameter ratio decrease with increasing Co{sup 2+} concentration in CdS. The diamagnetic state of CdS disappears with increase in Co concentration and films with x>0.02 exhibit ferromagnetism. This may be explained in terms of the spin–orbit interactions and Co{sup 2+} ion induced the lattice defects and phase separation. - Highlights: • Cd{sub 1−x}Co{sub x}S dilute magnetic semiconductor nanofilms (0≤x≤0.08 at%) deposited by CBD. • The diamagnetic state of CdS vanishes for x=0.02. • For x>0.02, dilute magnetic semiconductor nanofilms shows a ferromagnetic state.

  3. The effect of dilute baby shampoo on nasal mucociliary clearance in healthy subjects.

    Science.gov (United States)

    Isaacs, Seth; Fakhri, Samer; Luong, Amber; Whited, Chad; Citardi, Martin J

    2011-01-01

    Biofilm formation has been implicated as an etiologic factor in the development of chronic rhinosinusitis (CRS). Nasal irrigation with surfactants including dilute baby shampoo have been proposed as an antibiofilm treatment for CRS patients. The effect of dilute baby shampoo on normal sinonasal mucosal function is unknown. Mucociliary clearance time (MCT), as measured by the time in minutes for a subject to detect a sweet taste after the application of a saccharin granules at the anterior part of the inferior turbinate, was performed before and shortly after nasal irrigation with 50 ml of 1% baby shampoo (Johnson & Johnson, New Brunswick, NJ) in 27 healthy volunteers. Mean MCTs before and after irrigation were 12.09 (±4.83 minutes) and 15.45 (±7.71 minutes) minutes, respectively. The mean difference, 3.37 minutes, was statistically significant (p = 0.031). Pre- and post-MCTs for each subject were not correlated (r = 0.324; p = 0.100). Nasal irrigations with dilute baby shampoo increase MCTs in healthy subjects. The impact of such interventions in CRS patients warrants additional investigation.

  4. Inhibition Effect of Deanol on Mild Steel Corrosion in Dilute ...

    African Journals Online (AJOL)

    The influence of deanol on the corrosion behaviour of mild steel in dilute sulphuric acid with sodium chloride addition was studied by means of mass-loss, potentiodynamic polarization, electrode potential monitoring, scanning electron microscopy and statistical analysis. Results show that deanol performed excellently with ...

  5. A constant-volume rapid exhaust dilution system for motor vehicle particulate matter number and mass measurements.

    Science.gov (United States)

    Maricq, M Matti; Chase, Richard E; Xu, Ning; Podsiadlik, Diane H

    2003-10-01

    An improved version of the constant volume sampling (CVS) methodology that overcomes a number of obstacles that exist with the current CVS dilution tunnel system used in most diesel and gasoline vehicle emissions test facilities is presented. The key feature of the new sampling system is the introduction of dilution air immediately at the vehicle tailpipe. In the present implementation, this is done concentrically through a cylindrical air filter. Elimination of the transfer hose conventionally used to connect the tailpipe to the dilution tunnel significantly reduces the hydrocarbon and particulate matter (PM) storage release artifacts that can lead to wildly incorrect particle number counts and to erroneous filter-collected PM mass. It provides accurate representations of particle size distributions for diesel vehicles by avoiding the particle coagulation that occurs in the transfer hose. Furthermore, it removes the variable delay time that otherwise exists between the time that emissions exit the tailpipe and when they are detected in the dilution tunnel. The performance of the improved CVS system is examined with respect to diesel, gasoline, and compressed natural gas vehicles.

  6. Breast milk intake and mother to infant pesticide transfer measured by deuterium oxide dilution in agricultural and urban areas of Mexico.

    Science.gov (United States)

    Limon-Miro, Ana Teresa; Aldana-Madrid, Maria Lourdes; Alvarez-Hernandez, Gerardo; Antunez-Roman, Lesley Evelyn; Rodriguez-Olibarria, Guillermo; Valencia Juillerat, Mauro E

    2017-08-01

    Vector-borne diseases have increased pesticide use in urban areas (UA) and agricultural areas (AA) in Mexico. Breast milk can be contaminated by pesticide exposure. The objective of the study was to measure breast milk intake by deuterium oxide dilution as well as organochlorine and pyrethroid transfer from mother to infant in AA and UA of Sonora, Mexico. Human milk intake was determined by the 'dose-to-mother' technique using deuterium oxide (D 2 O) dilution. Mothers' body composition was also assessed by this technique and the intercept method. Pyrethroids (deltamethrin, cypermethrin and cyhalothrin) and organochlorine pesticide residues (p,p'- DDT, p,p'- DDE, p,p'- DDD) in breast milk samples were measured by gas chromatography. Sixty-two lactating women and their infants participated in the study, 32 lived in the UA and 30 lived in the AA. Breast milk intake was approximately 100 mL higher in the AA than in the UA 799 ± 193 and 707 ± 201 mL/day, respectively (p pesticides studied surpassed the Acceptable Daily Intake (ADI) in milk for humans according to EPA and FAO/WHO. In conclusion, breast milk intake was higher in the AA compared to the UA. The p,p'- DDT and cypermethrin levels in breast milk were higher in the UA compared to the AA. Since pesticide levels in human milk did not exceed the ADI, breastfeeding is still a safe practice and should be encouraged. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    International Nuclear Information System (INIS)

    Sahin, Guelden; Demirtas, Mehmet

    2006-01-01

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established

  8. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Guelden [Department of Radiology, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)]. E-mail: gsahin@medicine.ankara.edu.tr; Demirtas, Mehmet [Department of Hand Surgery, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)

    2006-06-15

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established.

  9. The Statistical Mechanics of Dilute, Disordered Systems

    Science.gov (United States)

    Blackburn, Roger Michael

    Available from UMI in association with The British Library. Requires signed TDF. A graph partitioning problem with variable inter -partition costs is studied by exploiting its mapping on to the Ashkin-Teller spin glass. The cavity method is used to derive the TAP equations and free energy for both extensively connected and dilute systems. Unlike Ising and Potts spin glasses, the self-consistent equation for the distribution of effective fields does not have a solution solely made up of delta functions. Numerical integration is used to find the stable solution, from which the ground state energy is calculated. Simulated annealing is used to test the results. The retrieving activity distribution for networks of boolean functions trained as associative memories for optimal capacity is derived. For infinite networks, outputs are shown to be frozen, in contrast to dilute asymmetric networks trained with the Hebb rule. For finite networks, a steady leaking to the non-retrieving attractor is demonstrated. Simulations of quenched networks are reported which show a departure from this picture: some configurations remain frozen for all time, while others follow cycles of small periods. An estimate of the critical capacity from the simulations is found to be in broad agreement with recent analytical results. The existing theory is extended to include noise on recall, and the behaviour is found to be robust to noise up to order 1/c^2 for networks with connectivity c.

  10. The effect of dilute acid pre-treatment process in bioethanol production from durian (Durio zibethinus) seeds waste

    Science.gov (United States)

    Ghazali, K. A.; Salleh, S. F.; Riayatsyah, T. M. I.; Aditiya, H. B.; Mahlia, T. M. I.

    2016-03-01

    Lignocellulosic biomass is one of the promising feedstocks for bioethanol production. The process starts from pre-treatment, hydrolysis, fermentation, distillation and finally obtaining the final product, ethanol. The efficiency of enzymatic hydrolysis of cellulosic biomass depends heavily on the effectiveness of the pre-treatment step which main function is to break the lignin structure of the biomass. This work aims to investigate the effects of dilute acid pre-treatment on the enzymatic hydrolysis of durian seeds waste to glucose and the subsequent bioethanol fermentation process. The yield of glucose from dilute acid pre-treated sample using 0.6% H2SO4 and 5% substrate concentration shows significant value of 23.4951 g/L. Combination of dilute acid pre-treatment and enzymatic hydrolysis using 150U of enzyme able to yield 50.0944 g/L of glucose content higher compared to normal pre-treated sample of 8.1093 g/L. Dilute acid pre-treatment sample also shows stable and efficient yeast activity during fermentation process with lowest glucose content at 2.9636 g/L compared to 14.7583g/L for normal pre-treated sample. Based on the result, it can be concluded that dilute acid pre-treatment increase the yield of ethanol from bioethanol production process.

  11. Evaluation of two different HEDP content kits: Stability study against dilution both in vivo and in vitro

    International Nuclear Information System (INIS)

    Inoue, O.; Ikeda, I.; Kurata, K.

    1982-01-01

    Two different HEDP content kits (Kit A, HEDP: 1 mg, SnCl 2 x 2H 2 O: 0.5 mg; and Kit B, HEDP: 10 mg, SnCl 2 x 2H 2 O: 0.5 mg) were evaluated for their stability against dillution. Sup(99m)Tc-HEDP solutions prepared from these two kits were diluted from 10 to 6000 fold with 0.9% NaCl solution just before evaluation both in vivo and in vitro. In the case of Kit A, significant soft tissue uptake in vivo and released free pertechnetate in vitro were observed by diluting the sup(99m)Tc-HEDP solution. On the other hand, sup(99m)Tc-HEDP prepared from Kit B was found to be sufficiently stable against dilution. The stability after preparation of each diluted sup(99m)-HEDP was also greatly affected by its HEDP concentration. Preliminary analysis of absorption spectra for each 99 Tc-HEDP indicated the possibility of two different sup(99m)Tc-HEDP complex formation by varied HEDP concentration. These results indicated that a cold reagent like Kit A might cause a higher soft tissue uptake due to its dilution in vivo during a clinical study for bone scanning. (orig.) [de

  12. The effect of ultrasound on particle size, color, viscosity and polyphenol oxidase activity of diluted avocado puree.

    Science.gov (United States)

    Bi, Xiufang; Hemar, Yacine; Balaban, Murat O; Liao, Xiaojun

    2015-11-01

    The effect of ultrasound treatment on particle size, color, viscosity, polyphenol oxidase (PPO) activity and microstructure in diluted avocado puree was investigated. The treatments were carried out at 20 kHz (375 W/cm(2)) for 0-10 min. The surface mean diameter (D[3,2]) was reduced to 13.44 μm from an original value of 52.31 μm by ultrasound after 1 min. A higher L(∗) value, ΔE value and lower a(∗) value was observed in ultrasound treated samples. The avocado puree dilution followed pseudoplastic flow behavior, and the viscosity of diluted avocado puree (at 100 s(-1)) after ultrasound treatment for 1 min was 6.0 and 74.4 times higher than the control samples for dilution levels of 1:2 and 1:9, respectively. PPO activity greatly increased under all treatment conditions. A maximum increase of 25.1%, 36.9% and 187.8% in PPO activity was found in samples with dilution ratios of 1:2, 1:5 and 1:9, respectively. The increase in viscosity and measured PPO activity might be related to the decrease in particle size. The microscopy images further confirmed that ultrasound treatment induced disruption of avocado puree structure. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Impaired Urine Dilution Capability in HIV Stable Patients

    Directory of Open Access Journals (Sweden)

    Waldo H. Belloso

    2014-01-01

    Full Text Available Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle’s loop (TALH is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney’s ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz’ test. Material & Methods. Chaimowitz’ test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir.

  14. Diagnosis of hemoparasitosis trough the spread-smear technique using a drop of blood clot

    Directory of Open Access Journals (Sweden)

    Neusa Saltiél Stobbe

    1992-12-01

    Full Text Available The spread-smear technique using a drop of blood clot and stained by diluted and undimitcd Giemsa stain was evaluated for the search of blood cell types and recognition of Babesia bovis, Babesia bigemina and Anaplasma marginale hemoparasites. The blood clot samples were taken from a 6 month-old calf experimentally inoculated with the blood from a Cattle Tick Fever carrier. The Technique was sumitable for the observation of different blood cells and for the recognition of the hemoparasites.

  15. New Insights into Butyrylcholinesterase Activity Assay: Serum Dilution Factor as a Crucial Parameter.

    Directory of Open Access Journals (Sweden)

    Joanna Jońca

    Full Text Available Butyrylcholinesterase (BChE activity assay and inhibitor phenotyping can help to identify patients at risk of prolonged paralysis following the administration of neuromuscular blocking agents. The assay plays an important role in clinical chemistry as a good diagnostic marker for intoxication with pesticides and nerve agents. Furthermore, the assay is also commonly used for in vitro characterization of cholinesterases, their toxins and drugs. There is still lack of standardized procedure for measurement of BChE activity and many laboratories use different substrates at various concentrations. The purpose of this study was to validate the BChE activity assay to determine the best dilution of human serum and the most optimal concentration of substrates and inhibitors. Serum BChE activity was measured using modified Ellman's method applicable for a microplate reader. We present our experience and new insights into the protocol for high-throughput routine assays of human plasma cholinesterase activities adapted to a microplate reader. During our routine assays used for the determination of BChE activity, we have observed that serum dilution factor influences the results obtained. We show that a 400-fold dilution of serum and 5mM S-butyrylthiocholine iodide can be successfully used for the accurate measurement of BChE activity in human serum. We also discuss usage of various concentrations of dibucaine and fluoride in BChE phenotyping. This study indicates that some factors of such a multicomponent clinical material like serum can influence kinetic parameters of the BChE. The observed inhibitory effect is dependent on serum dilution factor used in the assay.

  16. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    Science.gov (United States)

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period

  17. High-efficiency plasma catalytic removal of dilute benzene from air

    International Nuclear Information System (INIS)

    Fan, Hong-Yu; Shi, Chuan; Li, Xiao-Song; Zhao, De-Zhi; Xu, Yong; Zhu, Ai-Min

    2009-01-01

    Achieving complete oxidation, good humidity tolerance and low energy cost is the key issue that needs to be addressed in plasma catalytic volatile organic compounds removal from air. For this purpose, Ag/HZSM-5 catalyst-packed dielectric barrier discharge using a cycled system composed of a storage stage and a discharge stage was studied. For dilute benzene removal from simulated air, Ag/HZSM-5 catalysts exhibit not only preferential adsorption of benzene in humid air at the storage stage but also almost complete oxidation of adsorbed benzene at the discharge stage. Five 'storage-discharge' cycles were examined, which suggests that Ag/HZSM-5 catalysts are very stable during the cycled 'storage-discharge' (CSD) plasma catalytic process. High oxidation rate of absorbed benzene as well as low energy cost can be achieved at a moderate discharge power. In an example of the CSD plasma catalytic remedy of simulated air containing 4.7 ppm benzene with 50% RH and 600 ml min -1 flow rate, the energy cost was as low as 3.7 x 10 -3 kWh m -3 air. This extremely low energy cost to remove low-concentration pollutants from air undoubtedly makes the environmental applications of the plasma catalytic technique practical.

  18. Polaron in the dilute critical Bose condensate

    Science.gov (United States)

    Pastukhov, Volodymyr

    2018-05-01

    The properties of an impurity immersed in a dilute D-dimensional Bose gas at temperatures close to its second-order phase transition point are considered. Particularly by means of the 1/N-expansion, we calculate the leading-order polaron energy and the damping rate in the limit of vanishing boson–boson interaction. It is shown that the perturbative effective mass and the quasiparticle residue diverge logarithmically in the long-length limit, signalling the non-analytic behavior of the impurity spectrum and pole-free structure of the polaron Green’s function in the infrared region, respectively.

  19. Determination of dilution and quality control of total and anti ...

    African Journals Online (AJOL)

    Objective: To determine the correct dilution and Quality control commercial ELISA of total and anti-measles antibodies for HIV infected pregnant women. Design: A laboratory based study. Setting: The University of Nairobi, Department of Paediatrics laboratory. Subjects: HIV infected pregnant women enrolled and exposed to ...

  20. Electrochemical reduction of dilute chromate solutions on carbon felt electrodes

    NARCIS (Netherlands)

    Frenzel, Ines; Frenzel, I.; Holdik, Hans; Barmashenko, Vladimir; Stamatialis, Dimitrios; Wessling, Matthias

    2006-01-01

    Carbon felt is a potential material for electrochemical reduction of chromates. Very dilute solutions may be efficiently treated due to its large specific surface area and high porosity. In this work, the up-scaling of this technology is investigated using a new type of separated cell and

  1. Effect of wine dilution on the reliability of tannin analysis by protein precipitation

    DEFF Research Database (Denmark)

    Jensen, Jacob Skibsted; Werge, Hans Henrik Malmborg; Egebo, Max

    2008-01-01

    A reported analytical method for tannin quantification relies on selective precipitation of tannins with bovine serum albumin. The reliability of tannin analysis by protein precipitation on wines having variable tannin levels was evaluated by measuring the tannin concentration of various dilutions...... of five commercial red wines. Tannin concentrations of both very diluted and concentrated samples were systematically underestimated, which could be explained by a precipitation threshold and insufficient protein for precipitation, respectively. Based on these findings, we have defined a valid range...... of the tannin response in the protein precipitation-tannin assay, which suffers minimally from these problems....

  2. In-straw cryoprotectant dilution of IVP bovine blastocysts vitrified in hand-pulled glass micropipettes.

    Science.gov (United States)

    Vieira, A D; Forell, F; Feltrin, C; Rodrigues, J L

    2007-06-01

    The aim of this study was to determine the influence of two ethylene glycol-based vitrification solutions on in vitro and in vivo survival after in-straw cryoprotectant dilution of vitrified in vitro-produced bovine embryos. Day-7 expanded blastocysts were selected according to diameter (> or = 180 microm) and osmotic characteristics and randomly assigned to one of three groups (i) VSa: vitrification in 40% EG+17.1% SUC+0.1% PVA; (ii) VSb: vitrification in 20% EG+20% DMSO; (iii) control: non-vitrified embryos. Vitrification was performed in hand-pulled glass micropipettes (GMP) and cryoprotectant dilution in 0.25 ml straws after warming in a plastic tube. Embryo viability was assessed by re-expansion and hatching rates after 72 h of IVC and by pregnancy rates after direct transfer of vitrified embryos. No differences in re-expansion rates were observed between vitrified groups after 24 h in culture (VSa=84.5%; VSb=94.8%). However, fewer VSa embryos (55.2%, Pstraw cryoprotectant dilution and direct embryo transfer.

  3. Competition explains limited attention and perceptual resources: implications for perceptual load and dilution theories

    Directory of Open Access Journals (Sweden)

    Paige E. Scalf

    2013-05-01

    Full Text Available Both perceptual load theory and dilution theory purport to explain when and why task-irrelevant information, or so-called distractors are processed. Central to both explanations is the notion of limited resources, although the theories differ in the precise way in which those limitations affect distractor processing. We have recently proposed a neurally plausible explanation of limited resources in which neural competition among stimuli hinders their representation in the brain. This view of limited capacity can also explain distractor processing, whereby the competitive interactions and bias imposed to resolve the competition determine the extent to which a distractor is processed. This idea is compatible with aspects of both perceptual load and dilution models of distractor processing, but also serves to highlight their differences. Here we review the evidence in favor of a biased competition view of limited resources and relate these ideas to both classic perceptual load theory and dilution theory.

  4. Mixotrophic growth and biochemical analysis of Chlorella vulgaris cultivated with diluted monosodium glutamate wastewater.

    Science.gov (United States)

    Ji, Yan; Hu, Wenrong; Li, Xiuqing; Ma, Guixia; Song, Mingming; Pei, Haiyan

    2014-01-01

    Monosodium glutamate wastewater (MSGW) is a potential medium for microbial cultivation because of containing abundant organic nutrient. This paper seeks to evaluate the feasibility of growing Chlorella vulgaris with MSGW and assess the influence of MSGW concentration on the biomass productivity and biochemical compositions. The MSGW diluted in different concentrations was prepared for microalga cultivation. C. vulgaris growth was greatly promoted with MSGW compared with the inorganic BG11 medium. C. vulgaris obtained the maximum biomass concentration (1.02 g/L) and biomass productivity (61.47 mg/Ld) with 100-time diluted MSGW. The harvested biomass was rich in protein (36.01-50.64%) and low in lipid (13.47-25.4%) and carbohydrate (8.94-20.1%). The protein nutritional quality and unsaturated fatty acids content of algal increased significantly with diluted MSGW. These results indicated that the MSGW is a feasible alternative for mass cultivation of C. vulgaris. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Ferrimagnetic Properties of Bond Dilution Mixed Blume-Capel Model with Random Single-Ion Anisotropy

    International Nuclear Information System (INIS)

    Liu Lei; Yan Shilei

    2005-01-01

    We study the ferrimagnetic properties of spin 1/2 and spin-1 systems by means of the effective field theory. The system is considered in the framework of bond dilution mixed Blume-Capel model (BCM) with random single-ion anisotropy. The investigation of phase diagrams and magnetization curves indicates the existence of induced magnetic ordering and single or multi-compensation points. Special emphasis is placed on the influence of bond dilution and random single-ion anisotropy on normal or induced magnetic ordering states and single or multi-compensation points. Normal magnetic ordering states take on new phase diagrams with increasing randomness (bond and anisotropy), while anisotropy induced magnetic ordering states are always occurrence no matter whether concentration of anisotropy is large or small. Existence and disappearance of compensation points rely strongly on bond dilution and random single-ion anisotropy. Some results have not been revealed in previous papers and predicted by Neel theory of ferrimagnetism.

  6. The effects of heating and dilution on the rheological and physical properties of Tank 241-SY-101 waste

    International Nuclear Information System (INIS)

    Tingey, J.M.; Bredt, P.R.; Shade, E.H.

    1994-10-01

    Of the 177 high-level waste underground storage tanks at the Hanford Site, 25 have been identified as being potentially capable of generating and releasing flammable gas. Tank 241-SY-101 has exhibited periodic releases of gas, and in some cases the gas released has exceeded the lower flammable gas limit. The components of the released gas from Tank 241-SY-101 are hydrogen, nitrous oxide, nitrogen, ammonia, carbon monoxide, and methane. A mitigation strategy that may effectively reduce the retention and release of these gases and the release of flammable gases is dilution coupled with eating of the tank wastes. The purpose of this work was to determine changes in rheological and physical properties caused by heating and dilution of actual 241-SY-101 waste. In May and December 1991, following periodic gas releases, samples of the waste in Tank 241-SY-101 were obtained. Current work quantified the effects of heating coupled with NaOH dilution of a combination of waste samples from Tank 241-SY-101 characteristic of a non-convective layer. The experimental approach and results of this heating and dilution study on Tank 241-SY-101 waste samples are described in Sections 2 and 3, respectively. In Section 3.1, a discussion of the rheological properties of the waste as a function of shearing forces, volume percent dilution, and temperature is presented. In Section 3.2, the physical properties of the waste dilutions are described, including the densities of the slurry, filtered solids, and filtrate; the settling behavior; and the percent filtered solids in the composite sample and each of the composite dilutions. A brief discussion of the results and uncertainties is given is Section 3.3. The conclusions of this investigation are reported in Section 4

  7. Elucidating the role of ferrous ion cocatalyst in enhancing dilute acid pretreatment of lignocellulosic biomass

    Directory of Open Access Journals (Sweden)

    Wei Hui

    2011-11-01

    Full Text Available Abstract Background Recently developed iron cocatalyst enhancement of dilute acid pretreatment of biomass is a promising approach for enhancing sugar release from recalcitrant lignocellulosic biomass. However, very little is known about the underlying mechanisms of this enhancement. In the current study, our aim was to identify several essential factors that contribute to ferrous ion-enhanced efficiency during dilute acid pretreatment of biomass and to initiate the investigation of the mechanisms that result in this enhancement. Results During dilute acid and ferrous ion cocatalyst pretreatments, we observed concomitant increases in solubilized sugars in the hydrolysate and reducing sugars in the (insoluble biomass residues. We also observed enhancements in sugar release during subsequent enzymatic saccharification of iron cocatalyst-pretreated biomass. Fourier transform Raman spectroscopy showed that major peaks representing the C-O-C and C-H bonds in cellulose are significantly attenuated by iron cocatalyst pretreatment. Imaging using Prussian blue staining indicated that Fe2+ ions associate with both cellulose/xylan and lignin in untreated as well as dilute acid/Fe2+ ion-pretreated corn stover samples. Analyses by scanning electron microscopy and transmission electron microscopy revealed structural details of biomass after dilute acid/Fe2+ ion pretreatment, in which delamination and fibrillation of the cell wall were observed. Conclusions By using this multimodal approach, we have revealed that (1 acid-ferrous ion-assisted pretreatment increases solubilization and enzymatic digestion of both cellulose and xylan to monomers and (2 this pretreatment likely targets multiple chemistries in plant cell wall polymer networks, including those represented by the C-O-C and C-H bonds in cellulose.

  8. Flagging and correcting non-spectral matrix interferences with spatial emission profiles and gradient dilution in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Cheung, Yan; Schwartz, Andrew J.; Chan, George C.-Y.; Hieftje, Gary M.

    2015-01-01

    Matrix interference remains one of the most daunting challenges commonly encountered in inductively coupled plasma-atomic emission spectrometry (ICP-AES). In the present study, a method is described that enables identification and correction of matrix interferences in axial-viewed ICP-AES through a combination of spatial mapping and on-line gradient dilution. Cross-sectional emission maps of the plasma are used to indicate the presence of non-spectral (plasma-related and sample-introduction-related) matrix interferences. In particular, apparent concentrations of an analyte species determined at various radial locations in the plasma differ in the presence of a matrix interference, which allows the interference to be flagged. To correct for the interference, progressive, on-line dilution of the sample, performed by a gradient high-performance liquid-chromatograph pump, is utilized. The spatially dependent intensities of analyte emission are monitored at different levels of sample dilution. As the dilution proceeds, the matrix-induced signal variation is reduced. At a dilution where the determined concentrations become independent of location in the plasma, the matrix interference is minimized. - Highlights: • Non-spectral matrix interference in ICP-AES is flagged and minimized. • Emission from different locations of the plasma are collected simultaneously. • Spatially dependent determined concentrations indicate the presence of interference. • Gradient dilution is performed on both calibration standards and sample. • Optimal dilution factor to minimize interference is found as dilution increases

  9. Flagging and correcting non-spectral matrix interferences with spatial emission profiles and gradient dilution in inductively coupled plasma-atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Yan; Schwartz, Andrew J.; Chan, George C.-Y.; Hieftje, Gary M., E-mail: hieftje@indiana.edu

    2015-08-01

    Matrix interference remains one of the most daunting challenges commonly encountered in inductively coupled plasma-atomic emission spectrometry (ICP-AES). In the present study, a method is described that enables identification and correction of matrix interferences in axial-viewed ICP-AES through a combination of spatial mapping and on-line gradient dilution. Cross-sectional emission maps of the plasma are used to indicate the presence of non-spectral (plasma-related and sample-introduction-related) matrix interferences. In particular, apparent concentrations of an analyte species determined at various radial locations in the plasma differ in the presence of a matrix interference, which allows the interference to be flagged. To correct for the interference, progressive, on-line dilution of the sample, performed by a gradient high-performance liquid-chromatograph pump, is utilized. The spatially dependent intensities of analyte emission are monitored at different levels of sample dilution. As the dilution proceeds, the matrix-induced signal variation is reduced. At a dilution where the determined concentrations become independent of location in the plasma, the matrix interference is minimized. - Highlights: • Non-spectral matrix interference in ICP-AES is flagged and minimized. • Emission from different locations of the plasma are collected simultaneously. • Spatially dependent determined concentrations indicate the presence of interference. • Gradient dilution is performed on both calibration standards and sample. • Optimal dilution factor to minimize interference is found as dilution increases.

  10. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  11. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  12. Anomalous Capacitance Maximum of the Glassy Carbon-Ionic Liquid Interface through Dilution with Organic Solvents.

    Science.gov (United States)

    Bozym, David J; Uralcan, Betül; Limmer, David T; Pope, Michael A; Szamreta, Nicholas J; Debenedetti, Pablo G; Aksay, Ilhan A

    2015-07-02

    We use electrochemical impedance spectroscopy to measure the effect of diluting a hydrophobic room temperature ionic liquid with miscible organic solvents on the differential capacitance of the glassy carbon-electrolyte interface. We show that the minimum differential capacitance increases with dilution and reaches a maximum value at ionic liquid contents near 5-10 mol% (i.e., ∼1 M). We provide evidence that mixtures with 1,2-dichloroethane, a low-dielectric constant solvent, yield the largest gains in capacitance near the open circuit potential when compared against two traditional solvents, acetonitrile and propylene carbonate. To provide a fundamental basis for these observations, we use a coarse-grained model to relate structural variations at the double layer to the occurrence of the maximum. Our results reveal the potential for the enhancement of double-layer capacitance through dilution.

  13. 40 CFR 1065.140 - Dilution for gaseous and PM constituents.

    Science.gov (United States)

    2010-07-01

    ...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.140 Dilution for... and the exhaust gases. (2) Pressure control. Maintain static pressure at the location where raw exhaust is introduced into the tunnel within ± 1.2 kPa of atmospheric pressure. You may use a booster...

  14. Electrochemical reduction of metal ions in dilute solution using hydrogen

    NARCIS (Netherlands)

    Portegies Zwart, I.; Wijnbelt, E.C.W.; Janssen, L.J.J.

    1995-01-01

    Reduction of metal ions in dilute solutions is of great interest for purification of waste waters and process liquids. A new electrochemical cell has been introduced. This cell - a GBC-cell - is a combination of a gasdiffusion electrode in direct contact with a packed bed of carbon particles.

  15. SBR treatment of olive mill wastewaters: dilution or pre-treatment?

    Science.gov (United States)

    Farabegoli, G; Chiavola, A; Rolle, E

    2012-01-01

    The olive-oil extraction industry is an economically important activity for many countries of the Mediterranean Sea area, with Spain, Greece and Italy being the major producers. This activity, however, may represent a serious environmental problem due to the discharge of highly polluted effluents, usually referred to as 'olive mill wastewaters' (OMWs). They are characterized by high values of chemical oxygen demand (COD) (80-300 g/L), lipids, total polyphenols (TPP), tannins and other substances difficult to degrade. An adequate treatment before discharging is therefore required to reduce the pollutant load. The aim of the present paper was to evaluate performances of a biological process in a sequencing batch reactor (SBR) fed with pre-treated OMWs. Pre-treatment consisted of a combined acid cracking (AC) and granular activated carbon (GAC) adsorption process. The efficiency of the system was compared with that of an identical SBR fed with the raw wastewater only diluted. Combined AC and GAC adsorption was chosen to be used prior to the following biological process due to its capability of providing high removal efficiencies of COD and TPP and also appreciable improvement of biodegradability. Comparing results obtained with different influents showed that best performances of the SBR were obtained by feeding it with raw diluted OMWs (dOMWs) and at the lowest dilution ratio (1:25): in this case, the removal efficiencies were 90 and 76%, as average, for COD and TPP, respectively. Feeding the SBR with either the pre-treated or the raw dOMWs at 1:50 gave very similar values of COD reduction (74%); however, an improvement of the TPP removal was observed in the former case.

  16. Analyses of PWR boron dilution consequences with the Arrotta code

    International Nuclear Information System (INIS)

    Johanson, E.; Cheng, H.W.; Sehgal, B.R.

    1998-03-01

    During the past few years, major attention has been paid to analyzing the issue of reactivity initiated accidents (RIAs), of which the boron dilution event is of very special interest to the countries having pressurized water reactors (PWRs) in their nuclear power delivery systems. The scenario considered is that if an inadvertent accumulation of boron free water in one loop during reactor startup operations of a PWR and the inadvertent startup of the reactor coolant pump (RCP) in the loop. This could then lead to a rapid boron dilution in the core, which can in turn give rise to a power excursion. This report is devoted to studying the potential physical and thermal hydraulic consequences of a slug of diluted coolant entering the core after one RCP start under a couple of postulated cases. The severity of the consequences of such a scenario is primarily determined by the amount of positive reactivity insertion, and they are also related to the reactivity insertion rate. Therefore, in the report, detailed calculations and analyses have been carried out from case to case by using the well-known space-time kinetics code, ARROTTA. As a result, the spatial distribution for nodal power, fuel enthalpy, fuel temperature and clad outside temperature as well as the change in core reactivity, total core power and peak fuel temperature can be provided. In general, the maximum fuel enthalpy, peak fuel temperature, and clad outside temperature, for all the cases considered in the report, do not exceed their respective routine safety limitations because of the strong Doppler effect and moderator temperature feedback, except if the safety limitations on fuel enthalpy addition for high burnup fuel are drastically reduced

  17. A compact rotating dilution refrigerator

    Science.gov (United States)

    Fear, M. J.; Walmsley, P. M.; Chorlton, D. A.; Zmeev, D. E.; Gillott, S. J.; Sellers, M. C.; Richardson, P. P.; Agrawal, H.; Batey, G.; Golov, A. I.

    2013-10-01

    We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 10-3 rad s-1 up to angular velocities in excess of 2.5 rad s-1. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

  18. Tunnel backfill erosion by dilute water

    International Nuclear Information System (INIS)

    Olin, M.

    2014-03-01

    The goal was to estimate smectite release from tunnel backfill due to dilute groundwater pulse during post glacial conditions. The plan was to apply VTT's two different implementations (BESW D and BESW S ) of well-known model of Neretnieks et al. (2009). It appeared difficult to produce repeatable results using this model in COMSOL 4.2 environment, therefore a semi-analytical approximate approach was applied, which enabled to take into account both different geometry and smectite content in tunnel backfill as compared to buffer case. The results are quite similar to buffer results due to the decreasing effect of smaller smectite content and the increasing effect of larger radius. (orig.)

  19. Tunnel backfill erosion by dilute water

    Energy Technology Data Exchange (ETDEWEB)

    Olin, M. [VTT Technical Research Centre of Finland, Espoo (Finland)

    2014-03-15

    The goal was to estimate smectite release from tunnel backfill due to dilute groundwater pulse during post glacial conditions. The plan was to apply VTT's two different implementations (BESW{sub D} and BESW{sub S}) of well-known model of Neretnieks et al. (2009). It appeared difficult to produce repeatable results using this model in COMSOL 4.2 environment, therefore a semi-analytical approximate approach was applied, which enabled to take into account both different geometry and smectite content in tunnel backfill as compared to buffer case. The results are quite similar to buffer results due to the decreasing effect of smaller smectite content and the increasing effect of larger radius. (orig.)

  20. Alpha-clustering in dilute nucleonic sea

    International Nuclear Information System (INIS)

    Tohsaki, Akihiro

    1999-01-01

    α-clusters are expected to come out here and there in nucleonic sea owing to energetic benefit as its density is diluted. We propose a precise treatment to elucidate α-clusterized process in nucleonic sea after the breakdown of the uniformness. In order to do this, an infinite number of nucleons are considered by taking account of both the Pauli exclusion principle and effective internucleon forces. This method is called a microscopic approach, which has been successful in an α-cluster structure in light nuclei. In particular, we shed light on overcoming difficulties in a static model within the microscopic framework. This improvement is verified by using the empirical value in Weizaecker's mass formula. (author)

  1. Reverse isotope dilution method for determining benzene and metabolites in tissues

    International Nuclear Information System (INIS)

    Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.

    1988-01-01

    A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of the radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue

  2. Estimative of dilution factor for radioactive liquid effluents employing the H-3 and Cs-137 radiotracers present as pollutant

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa; Santos, Adir Janete Godoy dos

    2011-01-01

    It was estimated the dilution factor for liquid effluents at the discharge points of the IPEN, Sao Paulo, Brazil, employing as radiotracers the radioisotope routinely liberated for the sewage of 'Cidade Universitaria Armando de Salles Oliveira' - CUASO 3 H and 137 Cs, not generating either monetary or environmental cost associated to the estimation. The 137 Cs was determined by gamma spectrometry and the 3 H was determined liquid phase scintillation. The results showed that the dilution factor varied according to the employed radiotracer in a crescent order of 3 H and 137 Cs according to the characteristics of each element. The average of dilution factors obtained at the first and second liberation day were 4.3 and 7.4 respectively for the 3 H and 6.2 and 13.9 for the 137 Cs. The ratio of dilution factors of calculated 3 H and 137 Cs were coherent with the ratio verified at the twelve hydrometers distributed by the IPEN campus. The dilution factors were estimated in operational and laboratory study, in a single controlled discharge of the TR1 tank

  3. A Study Of The Dilution Of Radio-Active Waste In The Rhone (1961); Etude de la dilution dans le rhone des effluents radioactifs du Centre de Marcoule (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Scheidhauer, J; Marichal, M; Court, R [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1961-07-01

    The discharge into the Rhone of liquid radio-active waste from the Marcoule Centre necessitates a large number of measurements, in particular chemical and radio-chemical analysis of the waste, itself and of the waters of the Rhone both above arid below the point of discharge. The results thus obtained during 1960 made it possible to evaluate the total amount of active waste discharged and its dilution in the receiving medium. A statistical study of the results of the analysis of the Rhone waters shows that a satisfactory dilution of the waste occurs rapidly; the experimental results obtained with an experimental discharge of rhodamine are thus confirmed. (authors) [French] Le rejet au Rhone des effluents radioactifs liquides produits sur le Centre de Marcoule donne lieu a un grand nombre de mesures et en particulier d'analyses chimiques et radio-chimiques des effluents eux-memes ainsi que des eaux du Rhone avant et apres rejet. Au cours de l'annee 1960, l'ensemble des resultats ainsi obtenus a permis de dresser un bilan des activites rejetees et de leur dispersion dans le milieu recepteur. Une etude statistique des resultats d'analyses des eaux du Rhone montre qu'une dilution satisfaisante des effluents s'effectue rapidement confirmant ainsi les resultats obtenus lors d'un rejet experimental de rhodamine. (auteurs)

  4. Examples of Savannah River water dilution between the Savannah River Plant and the Beaufort-Jasper and Port Wentworth water-treatment plants

    International Nuclear Information System (INIS)

    Hayes, D.W.

    1983-01-01

    A substantial dilution of the river water occurs between the Savannah River Plant (SRP) and the two treatment plants. This dilution results from inflow of surface and groundwater and from direct rainfall. The amount of dilution was estimated to be approximately 20% and 54% down to the Port Wentworth and Beaufort-Jasper plants, respectively

  5. Corrosion of carbon steel and low-alloy steel in diluted seawater containing hydrazine under gamma-rays irradiation

    International Nuclear Information System (INIS)

    Nakano, Junichi; Yamamoto, Masahiro; Tsukada, Takashi

    2014-01-01

    Seawater was injected into reactor cores of Units 1, 2, and 3 in the Fukushima Daiichi nuclear power station as an urgent coolant. It is considered that the injected seawater causes corrosion of steels of the reactor pressure vessel and primary containment vessel. To investigate the effects of gamma-rays irradiation on weight loss in carbon steel and low-alloy steel, corrosion tests were performed in diluted seawater at 50°C under gamma-rays irradiation. Specimens were irradiated with dose rates of 4.4 kGy/h and 0.2 kGy/h. To evaluate the effects of hydrazine (N 2 H 4 ) on the reduction of oxygen and hydrogen peroxide, N 2 H 4 was added to the diluted seawater. In the diluted seawater without N 2 H 4 , weight loss in the steels irradiated with 0.2 kGy/h was similar to that in the unirradiated steels, and weight loss in the steels irradiated with 4.4 kGy/h increased to approximate 1.7 times of those in the unirradiated steels. Weight loss in the steels irradiated in the diluted seawater containing N 2 H 4 was similar to that in the diluted seawater without N 2 H 4 . When N 2 was introduced into the gas phase in the flasks during gamma-rays irradiation, weight loss in the steels decreased. (author)

  6. Hyperfine interactions in dilute Se doped Fe{sub x}Sb{sub 1−x} bulk alloy

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Mitesh, E-mail: miteshsarkar-msu@yahoo.com; Agrawal, Naveen [The M. S. University of Baroda, Department of Physics (India); Chawda, Mukesh [Polytechnic, The M. S. University of Baroda, Department of Applied Physics (India)

    2016-12-15

    Hyperfine Interaction technique like Moessbauer spectroscopy is a very sensitive tool to study the local probe interactions in Iron doped alloys and compounds. We report here the Moessbauer study of the effect of Fe concentration variations in dilute magnetic semiconducting Se{sub 0.004}Fe{sub x}Sb{sub 1−x} alloys for x = 0.002, 0.004 and 0.008. The materials were characterized using X-ray diffraction technique (XRD), Fourier Transform Infra-red spectroscopy (FTIR), Neutron depolarization and Moessbauer spectroscopy. The FTIR result shows the semiconducting behavior of the alloys with band gap of 0.18 eV. From Moessbauer spectroscopy two magnetic sites (A and B) were observed. The value of hyperfine magnetic fields (HMF) of ∼ 308 kOe (site A) and 270 kOe (site B) was constant with increase in Fe concentration. A nonmagnetic interaction was also observed with quadrupole splitting (QS) of 1.26 mm/sec (site C) for x = 0.004 and x = 0.008. The Neutron depolarization studies indicate that the clusters of Fe or Fe based compounds having net magnetic moments with a size greater than 100 Å is absent.

  7. Evaluation of isotopic dilution method for measuring N2 fixation in azolla: comparison with other methods

    International Nuclear Information System (INIS)

    Sah, R.N.; Goyal, S.S.; Rains, D.W.; Paige, D.F.

    1989-01-01

    An isotopic dilution method that overcomes the drawbacks of commonly used methods for measuring N 2 fixation by aquatic N‐fixers such as Azolla pinnata‐Anabaena azollae association (Azolla) is presented. The method was compared with 15 N2 gas (while maintaining CO 2 ) and the difference methods of measuring N 2 fixation. The isotopic dilution method was used for two conditions: a. For 15 N‐free growth medium, Azolla was pre‐enriched with 15 N, and N 2 fixation was determined by measuring the dilution of 15 N in the tissue. b. For the growth medium containing N, N2 fixation was determined by providing 15 N enriched ammonium sulfate in the growth medium and measuring 15 N to 14 N ratio in the tissue. An airtight chamber, necessary for 15 N 2 gas and acetylene reduction methods, was not representative of the growing environment of Azolla. Temperature in the airtight chamber was far from uniform and CO 2 was rapidly depleted. The isotopic dilution method is simpler, relatively inexpensive, subject to fewer errors and applicable to more diverse conditions, and yet was as accurate as 15 N2‐gas method. (author)

  8. Low frequency complex dielectric (conductivity) response of dilute clay suspensions: Modeling and experiments.

    Science.gov (United States)

    Hou, Chang-Yu; Feng, Ling; Seleznev, Nikita; Freed, Denise E

    2018-04-11

    In this work, we establish an effective medium model to describe the low-frequency complex dielectric (conductivity) dispersion of dilute clay suspensions. We use previously obtained low-frequency polarization coefficients for a charged oblate spheroidal particle immersed in an electrolyte as the building block for the Maxwell Garnett mixing formula to model the dilute clay suspension. The complex conductivity phase dispersion exhibits a near-resonance peak when the clay grains have a narrow size distribution. The peak frequency is associated with the size distribution as well as the shape of clay grains and is often referred to as the characteristic frequency. In contrast, if the size of the clay grains has a broad distribution, the phase peak is broadened and can disappear into the background of the canonical phase response of the brine. To benchmark our model, the low-frequency dispersion of the complex conductivity of dilute clay suspensions is measured using a four-point impedance measurement, which can be reliably calibrated in the frequency range between 0.1 Hz and 10 kHz. By using a minimal number of fitting parameters when reliable information is available as input for the model and carefully examining the issue of potential over-fitting, we found that our model can be used to fit the measured dispersion of the complex conductivity with reasonable parameters. The good match between the modeled and experimental complex conductivity dispersion allows us to argue that our simplified model captures the essential physics for describing the low-frequency dispersion of the complex conductivity of dilute clay suspensions. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. In vitro dilutions of thioridaxine with potential to enhance antibiotic ...

    African Journals Online (AJOL)

    Gram staining, catalase test and coagulase test were done on the resulting colonies to further confirm the strains as S. aureus. Antibiotic susceptibility test was done by agar disc diffusion method using sterile Mueller- Hinton agar plates before and after treatment with laboratory dilutions of thioridaxine. S. aureus strains 1, ...

  10. Preparation of standard mixtures of gas hydrocarbons in air by the diffusion dilution method

    International Nuclear Information System (INIS)

    Garcia, M. R.; Perez, M. M.

    1979-01-01

    An original diffusion system able to produce continuously gaseous samples is described. This system can generate samples with concentrations of benzene in air from 0.1 to 1 ppm a reproducible way. The diffusion dilution method used Is also studied. The use of this diffusion system has been extended to the preparation of binary mixtures (benzene-toluene). Whit a secondary dilution device is possible preparing these mixtures over a wide range of concentrations (0.11 to 0.04 ppm for benzene and 0.06 to 0.02 for toluene). (Author) 7 refs

  11. ISOLATION OF TYPICAL MARINE-BACTERIA BY DILUTION CULTURE - GROWTH, MAINTENANCE, AND CHARACTERISTICS OF ISOLATES UNDER LABORATORY CONDITIONS

    NARCIS (Netherlands)

    SCHUT, F; DEVRIES, EJ; GOTTSCHAL, JC; ROBERTSON, BR; HARDER, W; PRINS, R A; BUTTON, DK

    Marine bacteria in Resurrection Bay near Seward, Alaska, and in the central North Sea off the Dutch coast were cultured in filtered autoclaved seawater following dilution to extinction. The populations present before dilution varied from 0.11 x 10(9) to 1.07 x 10(9) cells per liter. The mean cell

  12. Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, E. [CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Université Paris-Saclay, 91405 Orsay (France); Billard, J.; De Jesus, M.; Juillard, A. [Univ Lyon, Université Lyon 1, CNRS/IN2P3, IPN-Lyon, F-69622 Villeurbanne (France); Leder, A. [Massachussets Institute of Technology, Laboratory for Nuclear Science, 77 Massachusetts Avenue Cambridge, MA 02139-4307 (United States)

    2017-06-21

    Dry Dilution Refrigerators (DDR) based on pulse tube cryo-coolers have started to replace Wet Dilution Refrigerators (WDR) due to the ease and low cost of operation. However these advantages come at the cost of increased vibrations, induced by the pulse tube. In this work, we present the vibration measurements performed on three different commercial DDRs. We describe in detail the vibration measurement system we assembled, based on commercial accelerometers, conditioner and DAQ, and examined the effects of the various damping solutions utilized on three different DDRs, both in the low and high frequency regions. Finally, we ran low temperature, pseudo-massive (30 and 250 g) germanium bolometers in the best vibration-performing system under study and report on the results.

  13. Estimation of nitrogen fixation in Saccharum spp. by 15N dilution method

    International Nuclear Information System (INIS)

    Singh, Mohan

    1994-01-01

    The amount of nitrogen fixed by bacteria associated with the roots of Saccharum spontaneum, S. sinense, and S. barberi has been estimated by 15 N-isotope dilution method using Sclerotachya fusca as a non-fixing control. S. spontaneum produced highest shoot dry weight among the species tested but maximum nitrogen was accumulated by S. barberi. Highest dilution in the 15 N-enrichment was observed in S. spontaneum followed by S. sinense and S. barberi in comparison to the control plant of Sclerotchya fusca. S. spontaneum derived 60 per cent followed by S. sinense 54 per cent and S. barberi 35 per cent of their total nitrogen requirement through fixation of nitrogen by diazotrophic bacteria associated with their roots. (author). 11 refs., 2 tabs

  14. Mortality reduction by post-dilution online-haemodiafiltration : A cause-specific analysis

    NARCIS (Netherlands)

    Nubé, Menso J.; Peters, Sanne A E; Blankestijn, Peter J.; Canaud, Bernard; Davenport, Andrew; Grooteman, Muriel P C; Asci, Gulay; Locatelli, Francesco; Maduell, Francisco; Morena, Marion; Ok, Ercan; Torres, Ferran; Bots, Michiel L.; Moreso, Francesc; Pons, Mercedes; Ramos, Rosa; Mora-Macià, Josep; Carreras, Jordi; Soler, Jordi; Campistol, Josep M.; Martinez-Castelao, Alberto; Insensé, B.; Perez, C.; Feliz, T.; Barbetta, M.; Soto, C.; Mora, J.; Juan, A.; Ibrik, O.; Foraster, A.; Nin, J.; Fernández, A.; Arruche, M.; Sánchez, C.; Vidiella, J.; Barbosa, F.; Chiné, M.; Hurtado, S.; Llibre, J.; Ruiz, A.; Serra, M.; Salvó, M.; Poyuelo, T.; Maduell, F.; Carrera, M.; Fontseré, N.; Arias, M.; Merín, A.; Ribera, L.; Galceran, J. M.; Mòdol, J.; Moliner, E.; Ramirez, A.; Aguilera, J.; Alvarez, M.; De La Torre, B.; Molera, M.; Casellas, J.; Martín, G.; Andres, E.; Coll, E.; Valles, M.; Martínez, C.; Castellote, E.; Casals, J. M.; Gabàs, J.; Romero, M.; Martinez-Castelao, A.; Fulladosa, X.; Ramirez-Arellano, M.; Fulquet, M.; Pelegrí, A.; El Manouari, M.; Ramos, N.; Bartolomé, J.; Sans, R.; Fernández, E.; Sarró, F.; Compte, T.; Marco, F.; Mauri, R.; Bronsoms, J.; Arnaiz, J. A.; Beleta, H.; Pejenaute, A.; Ríos, J.; Lara, J.; Ter Wee, P. M.; Van Den Dorpel, M. A.; Dorval, M.; Lévesque, R.; Koopman, M. G.; Konings, C. J A M; Haanstra, W. P.; Kooistra, M.; Van Jaarsveld, B.; Noordzij, T.; Feith, G. W.; Peltenburg, H. G.; Van Buren, M.; Offerman, J. J G; Hoogeveen, E. K.; De Heer, F.; Van De Ven, P. J.; Kremer Hovinga, T. K.; Bax, W. A.; Groeneveld, J. O.; Lavrijssen, A. T J; Schrander-Van Der Meer, A. M.; Reichert, L. J M; Huussen, J.; Rensma, P. L.; Schrama, Y.; Van Hamersvelt, H. W.; Boer, W. H.; Van Kuijk, W. H.; Vervloet, M. G.; Wauters, I. M P M J; Sekse, I.; Toz, Huseyin; Ok, Ebru Sevinc; Kircelli, Fatih; Yilmaz, Mumtaz; Hur, Ender; Demirci, Meltem Sezis; Demirci, Cenk; Duman, Soner; Basci, Ali; Adam, Siddig Momin; Isik, Ismet Onder; Zengin, Murat; Suleymanlar, Gultekin; Yilmaz, Mehmet Emin; Ergin, Mehmet Ozkahya Pinar; Sagdic, Alfert; Kayali, Erkan; Boydak, Can; Colak, Taskin; Caliskan, Sihli; Kaplan, Hakan; Ulas, Hasibe; Kirbiyik, Sait; Berktas, Hakan; Dilbaz, Necati; Cristol, Jean Paul; Leray-Moragues, Hélène; Chenine, Leïla; Picot, Marie Christine; Jaussent, Audrey; Belloc, Claire; Lagarrigue, Mélodie; Chalabi, Lotfi; Debure, Alain; Ouziala, Messaoud; Lefevre, Jean Jacques; Thibaudin, Damien; Mohey, Hesham; Broyet, Christian; Afiani, Aida; Serveaux, Marie Odile; Patrier, Laure; Maurice, François; Rivory, Jean Pierre; Nicoud, Philippe; Durand, Claude; Normand, Michel; Seigneuric, Bruno; Magnant, Eric; Azzouz, Lynda; Islam, Mohamed Shariful; Vido, Sandor; Nzeyimana, Hilaire; Simonin, Danièle; Azymah, Yamina; Farah, Ibrahim; Coindre, Jean Philippe; Puyoo, Olivier; Chabannier, Marie Hélène; Ibos, Richard; Rouleau, Fabienne; Vela, Carlos; Joule, Josiane; Combarnous, François; Turc-Baron, Cécile; Ducret, Francis; Pointet, Philippe; Rey, Isabelle; Potier, Jacky; Bendini, Jean Christophe; Perrin, Franck; Kunz, Kristian; Lefrancois, Gaëlle; Colin, Angélique; Parahy, Sophie; Dancea, Irima; Coupel, Stéphanie; Testa, Angelo; Brunet, Philippe; Lebrun, Gaétan; Jaubert, Dominique; Delcroix, Catherine; Lavainne, Frédéric; Lefebvre, Anne; Guillodo, Marie Paule; Le Grignou, Dominique; Djema, Assia; Maaz, Mehadji; Chiron, Sylvie; Hoffmann, Maxime; Depraetre, Pascale; Haddj-Elmrabet, Atman; Joyeux, Véronique; Fleury, Dominique; Vrigneaud, Laurence; Lemaitre, Vincent; Aguilera, Didier; Guerraoui, Abdallah; Cremault, Alain; Laradi, Achour; Babinet, Francois

    Background. From an individual participant data (IPD) meta-analysis from four randomized controlled trials comparing haemodialysis (HD) with post-dilution online-haemodiafiltration (ol-HDF), previously it appeared that HDF decreases all-cause mortality by 14% (95% confidence interval 25; 1) and

  15. Identification of ultrasound-contrast-agent dilution systems for ejection fraction measurements

    NARCIS (Netherlands)

    Mischi, M.; Jansen, A.H.M.; Kalker, A.A.C.M.; Korsten, H.H.M.

    2005-01-01

    Left ventricular ejection fraction is an important cardiac-efficiency measure. Standard estimations are based on geometric analysis and modeling; they require time and experienced cardiologists. Alternative methods make use of indicator dilutions, but they are invasive due to the need for

  16. Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ohata, Masaki; Miura, Tsutomu

    2014-01-01

    Highlights: • Accurate analytical method of Br in plastic was studied by isotope dilution ICPMS. • A microwave acid digestion using quartz vessel was suitable for Br analysis. • Sample dilution by NH 3 solution could remove memory effect for ICPMS measurement. • The analytical result of the ID-ICPMS showed consistency with that of INAA. • The ID-ICPMS developed could apply to certification of Br in candidate plastic CRM. - Abstract: The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH 3 ) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH 3 solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive

  17. Radiotracer study to investigate the dilution and dispersion of sewage off Worli coast

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Pendharkar, A.S.; Agashe, S.M.; Kumar, U.S.; Kulkarni, U.P.; Mendhekar, G.N.; Navada, S.V.

    1998-01-01

    Radiotracer experiments were carried out off Worli Coast, Mumbai to study the dilution and dispersion of sewage from the proposed out fall at 3000 m and existing out fall at 500 m from the shore. Dilutions observed were 2.3 x 10 7 at 3.3 km from the injection point for the disposal at 3,000 m and 6.9 x 10 5 at 5 km for the disposal at 500 m. Dispersion coefficients obtained from two dimensional advection dispersion model for the experiment off 500 m are Dx 15-18 m 2 /s and Dy = 0.5-2 m 2 /s. (author)

  18. Establishment and application of deuterium dilution method for measuring breastmilk intake of Pakistani infants

    International Nuclear Information System (INIS)

    Bilal, R.; Roohi, S.; Sajjad, M.I.; Abbas, K.A.; Latif, Z.

    2000-01-01

    We established the deuterium dilution method in our laboratory and have applied it in the field for quantification of milk intake of babies. A comparison of the test weighing (TW) data with the D 2 O data is also being made. The growth of children fed exclusively on breast milk is also being monitored. The method once established will be made available for various projects where correct estimation of milk intake/out put is desired. First year of the project was devoted to standardization of the D/H preparation from biological fluids using Zn shot method. During the report period, the D 2 O dilution methodology for measuring the breast milk intake of infants was streamlined. 21 infant-mother pairs have been recruited and data including deuterium dilution assay was collected at 4 weeks of age. Growth of the infants is being followed up-till six month. Analysis of 21 infant mothers data is presented. Samples of six infant mother pairs collected at 13. week of age are waiting to be analyzed. The mean breast milk intake of infants measured by deuterium dilution method is 801 ± 262 gm at first sampling at 31.15 ± 7.7 days of age (n=18). The milk intake determined by test weighing was significantly higher than estimated by D 2 O dilution. The values were 1169 ± 384 per day as compared to 705 ± 129 per day for TW and D 2 O method respectively (n=13). The growth data collected over six month period for 21 infants showed that they fall within 5 percentile of NCHS for weight. The height of boys is in 50 percentile whereas for girls it at 5 percentile. The data collected so far suggest that although majority of infants are exclusively breast fed and the intake values are normal yet their growth is far from optimum. This emphasizes the need to take up the studies involving quality of milk in relation to the nutritional status of the mothers. (author)

  19. 3-D Surface Visualization of pH Titration "Topos": Equivalence Point Cliffs, Dilution Ramps, and Buffer Plateaus

    Science.gov (United States)

    Smith, Garon C.; Hossain, Md Mainul; MacCarthy, Patrick

    2014-01-01

    3-D topographic surfaces ("topos") can be generated to visualize how pH behaves during titration and dilution procedures. The surfaces are constructed by plotting computed pH values above a composition grid with volume of base added in one direction and overall system dilution on the other. What emerge are surface features that…

  20. The construction of a Pomeranchuk cell driven by a 4He-circulating dilution refrigerator and some related experiments

    International Nuclear Information System (INIS)

    Brandt, B. van den.

    1981-01-01

    This thesis deals with some investigations at very low temperatures in which a 4 He-circulating 3 He- 4 He dilution refrigerator and a Pomeranchuk cooling device are used. The main theme is the design and construction of a special device, a Pomeranchuk cell that is precooled and pressurized with a 4 He-circulating 3 He- 4 He dilution refrigerator, that can be used to obtain a lowest temperature of the order of 1.1 mK. Furthermore, some details of the working of such a dilution refrigerator and some properties of 3 He- 4 He mixtures at high pressures were investigated. (Auth.)