WorldWideScience

Sample records for dilution technique otimizacao

  1. A century of indicator dilution technique

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Jensen, Gorm B; Larsson, Henrik B W

    2014-01-01

    This review imparts the history and the present status of the indicator dilution technique with quantitative bolus injection. The first report on flow measurement with this technique appeared 100 years ago. In 1928, the use of intravascular dyes made possible a widespread application in animals...

  2. Quantification of Labile Soil Mercury by Stable Isotope Dilution Techniques

    Science.gov (United States)

    Shetaya, Waleed; Huang, Jen-How; Osterwalder, Stefan; Alewell, Christine

    2016-04-01

    Mercury (Hg) is a toxic element that can cause severe health problems to humans. Mercury is emitted to the atmosphere from both natural and anthropogenic sources and can be transported over long distances before it is deposited to aquatic and terrestrial environments. Aside from accumulation in soil solid phases, Hg deposited in soils may migrate to surface- and ground-water or enter the food chain, depending on its lability. There are many operationally-defined extraction methods proposed to quantify soil labile metals. However, these methods are by definition prone to inaccuracies such as non-selectivity, underestimation or overestimation of the labile metal pool. The isotopic dilution technique (ID) is currently the most promising method for discrimination between labile and non-labile metal fractions in soil with a minimum disturbance to soil-solid phases. ID assesses the reactive metal pool in soil by defining the fraction of metal both in solid and solution phases that is isotopically-exchangeable known as the 'E-value'. The 'E-value' represents the metal fraction in a dynamic equilibrium with the solution phase and is potentially accessible to plants. This is carried out by addition of an enriched metal isotope to soil suspensions and quantifying the fraction of metal that is able to freely exchange with the added isotope by measuring the equilibrium isotopic ratio by ICP-MS. E-value (mg kg-1) is then calculated as follows: E-Value = (Msoil/ W) (CspikeVspike/ Mspike) (Iso1IAspike -Iso2IAspikeRss / Iso2IAsoil Rss - Iso1IAsoil) where M is the average atomic mass of the metal in the soil or the spike, W is the mass of soil (kg), Cspike is the concentration of the metal in the spike (mg L-1), Vspike is the volume of spike (L), IA is isotopic abundance, and Rss is the equilibrium ratio of isotopic abundances (Iso1:Iso2). Isotopic dilution has been successfully applied to determine E-values for several elements. However, to our knowledge, this method has not yet

  3. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition.

    Science.gov (United States)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita; Friis, Henrik; Kurpad, Anura; Wells, Jonathan C

    2017-08-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work to develop and adapt the deuterium dilution technique. We refined procedures for administration of isotope doses and collection of saliva. Furthermore, we established that equilibration time in local context is 3 h. These findings and the resulting standard operating procedures are important to improve data quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques.

  4. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition

    DEFF Research Database (Denmark)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita

    2017-01-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body...... composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work...... quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques....

  5. Renal artery blood flow assessed by video dilution technique before and after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Link, D.P.; Lewis, E.L.; Foerster, J.M.; Lee, G.

    1981-01-01

    Successful percutaneous transluminal angioplasty was performed in 3 cases of renal artery stenosis where the effect upon renal blood flow was quantified by video dilution technique. This technique adds important information to pressure gradients and renin assays obtained during the dilatation procedure. (Auth.)

  6. Study of an optimization protocol for radiographic techniques in computerized radiology; Estudo de um protocolo de otimizacao para as tecnicas radiograficas em radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Marcos Eugenio Silva

    2015-07-01

    This work is designed to produce information for the improvement of image quality to deployment in a radiology department based on previous reviews of the images by questionnaires of acceptance and quality e recognition of the parameters used in chest radiographic techniques. The data collected were divided by male, female, PA and LAT thickness, body mass index, biotypes, anthropomorphic parameters and body evaluation associated with constant voltage and the additional filtration. The results show the predominance of 35 and 40 constants with additional filtration from 0.5 to 1.5 mmAl, voltage in male: (PA and LAT) 86-92 kV and 96-112 kV, female: 85-98 kV and 96-112 kV. The charge applied to the tube for males: (PA and LAT) 5-10 mA.s and 5-16 mA.s, female: (PA and LAT) 6.3-8 mA.s and 9-14 mA.s. Absorbed doses for males: (PA and PF) 0.04-0.17 mGy and 0.03-0.19 mGy and from female (PA and PF) from 0.03-0.22 mGy and 0, 04-0.17 mGy. This procedure can be used in radiology department to implement and acceptance in the quality of images. (author)

  7. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  8. Simulation of limiting dilution technique in determination of immunocompetent cells frequency in irradiated cell cultures

    International Nuclear Information System (INIS)

    Martini Filho, R.J.; Barlette, V.E.; Goes, E.G.; Covas, D.T.; Orellana, M.

    2001-01-01

    Limiting dilution techniques (LDA) dose-response data have been used to detect immunocompetent T-Cells in microcultures. In this work, LDA frequencies estimates was obtained using χ2 minimization for irradiated cells in a range of 500 to 1,500 cGy. (author)

  9. Study of dilution of effluent discharged through a sea outfall near Mangalore using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.

    1987-01-01

    The fate of effluent discharged into water bodies is a matter of concern from the point of view of environmental pollution. Radiotracer techniques have been successfully used to study the change in concentration of effluents while being mixed with large water bodies. The technique used is to add a known concentration of radioactive tracer into the effluent stream and to measure the dilutions at different locations near the effluent discharge point with radiation detectors. M/s Mangalore Chemicals and Fertilizers Ltd (MCF) at Mangalore on the west coast of India disposes off the treated and initially diluted effluent at the rate of about 360 m 3 /h into the sea near by through an outfall extending about 100 meters into the sea. The effluent mainly contains ammonia in the range of 40-50 ppm as the pollutant. It was desired to measure the extent of dilution occurring to the effluent at a few locations of known distances along the sea shore from the discharge point of the effluent. Radiotracers 82 Br as ammonium bromide solution and tritium as tritiated water were employed for the study. The concentration measurement was done at site for 82 Br and by estimation of samples in the laboratory in the case of tritium. Dilution of the order of 1000 was obtained at about 100 meters distance for a continuous injection of about 4 hours. (author). 3 tables, 3 figures

  10. 15N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    International Nuclear Information System (INIS)

    Ventura, Wilbur; Watanabe, Iwao

    1983-01-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the 15 N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. 15 N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower 15 N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N 2 fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the 15 N content of plants decreased in allowing the photodependent N 2 fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N 2 fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the 15 N dilution technique using the rice-covered soil as reference system. (Mori, K.)

  11. /sup 15/N dilution technique of assessing the contribution of nitrogen fixation to rice plant

    Energy Technology Data Exchange (ETDEWEB)

    Ventura, W; Watanabe, Iwao [International Rice Research Inst., College, Laguna (Phillippines)

    1983-06-01

    An attempt to correlate the positive nitrogen balance in rice-soil system with the /sup 15/N dilution in rice plants was made to see if isotope dilution can be used to assess the contribution of nitrogen fixation to the nitrogen nutrition of rice. /sup 15/N ammonium sulfate and sucrose were added to the moist soil in pots to label biomass nitrogen fraction. The rice-soil system with higher nitrogen gain had lower /sup 15/N content in the rice plants. When the surface of pots was covered with black cloths to suppress photodependent N/sub 2/ fixation, no significant nitrogen gain was observed. Significant gain was found in the rice-flooded soil system exposed to light, and the /sup 15/N content of plants decreased in allowing the photodependent N/sub 2/ fixation by blue-green algae symbiosis. The contribution of plant nitrogen derived from photodependent N/sub 2/ fixation was estimated to be 20-30 % of the positive nitrogen gain in the system by the /sup 15/N dilution technique using the rice-covered soil as reference system.

  12. DMSP and DMS dynamics and microzooplankton grazing in the Labrador Sea: application of the dilution technique

    Science.gov (United States)

    Wolfe, Gordon V.; Levasseur, Maurice; Cantin, Guy; Michaud, Sonia

    2000-12-01

    We adapted the dilution technique to study microzooplankton grazing of algal dimethylsulfoniopropionate (DMSP) vs. Chl a, and to estimate the impact of microzooplankton grazing on dimethyl sulfide (DMS) production in the Labrador Sea. Phytoplankton numbers were dominated by autotrophic nanoflagellates in the Labrador basin, but diatoms and colonial Phaeocystis pouchetii contributed significantly to phytomass at several high chlorophyll stations and on the Newfoundland and Greenland shelfs. Throughout the region, growth of algal Chl a and DMSP was generally high (0.2-1 d -1), but grazing rates were lower and more variable, characteristic of the early spring bloom period. Production and consumption of Chl a vs. DMSP followed no clear pattern, and sometimes diverged greatly, likely because of their differing distributions among algal prey taxa and size class. In several experiments where Phaeocystis was abundant, we observed DMS production proportional to grazing rate, and we found clear evidence of DMS production by this haptophyte following physical stress such as sparging or filtration. It is possible that grazing-activated DMSP cleavage by Phaeocystis contributes to grazer deterrence: protozoa and copepods apparently avoided healthy colonies (as judged by relative growth and grazing rates of Chl a and DMSP), and grazing of Phaeocystis was significant only at one station where cells were in poor condition. Although we hoped to examine selective grazing on or against DMSP-containing algal prey, the dilution technique cannot differentiate selective ingestion and varying digestion rates of Chl a and DMSP. We also found that the dilution method alone was poorly suited for assessing the impact of grazing on dissolved sulfur pools, because of rapid microbial consumption and the artifactual release of DMSP and DMS during filtration. Measuring and understanding the many processes affecting organosulfur cycling by the microbial food web in natural populations remain a

  13. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  14. Investigation of CTBT OSI Radionuclide Techniques at the DILUTED WATERS Nuclear Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Baciak, James E.; Milbrath, Brian D.; Detwiler, Rebecca S.; Kirkham, Randy R.; Keillor, Martin E.; Lepel, Elwood A.; Seifert, Allen; Emer, Dudley; Floyd, Michael

    2012-11-01

    Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), a verification regime that includes the ability to conduct an On-Site Inspection (OSI) will be established. The Treaty allows for an OSI to include many techniques, including the radionuclide techniques of gamma radiation surveying and spectrometry and environmental sampling and analysis. Such radioactivity detection techniques can provide the “smoking gun” evidence that a nuclear test has occurred through the detection and quantification of indicative recent fission products. An OSI faces restrictions in time and manpower, as dictated by the Treaty; not to mention possible logistics difficulties due to the location and climate of the suspected explosion site. It is thus necessary to have a good understanding of the possible source term an OSI will encounter and the proper techniques that will be necessary for an effective OSI regime. One of the challenges during an OSI is to locate radioactive debris that has escaped an underground nuclear explosion (UNE) and settled on the surface near and downwind of ground zero. To support the understanding and selection of sampling and survey techniques for use in an OSI, we are currently designing an experiment, the Particulate Release Experiment (PRex), to simulate a small-scale vent from an underground nuclear explosion. PRex will occur at the Nevada National Security Site (NNSS). The project is conducted under the National Center for Nuclear Security (NCNS) funded by the National Nuclear Security Agency (NNSA). Prior to the release experiment, scheduled for Spring of 2013, the project scheduled a number of activities at the NNSS to prepare for the release experiment as well as to utilize the nuclear testing past of the NNSS for the development of OSI techniques for CTBT. One such activity—the focus of this report—was a survey and sampling campaign at the site of an old UNE that vented: DILUTED WATERS. Activities at DILUTED WATERS included vehicle-based survey

  15. Utilization of tritiated water dilution technique in determination of nitrogen partitioning in cashmere goats

    International Nuclear Information System (INIS)

    Wang Linfeng; Yang Gaiqing; Liu Ping; Zhang Shijun

    2010-01-01

    In order to investigate nitrogen partitioning in local cashmere goats, six Inner Mogolia White Cashmere goats between 2 to 2.5 years old were used to determine the nitrogen partitioning in cashmere goats. The total retained nitrogen (TN) in body, distribution of body nitrgen and hair nitrogen were measured by general digestive and metabolism method combined with tritiated water dilution technique. Results showed that the combined methods were ideal for determining body nitrgen (BN) and hair nitrogen (fur nitrogen, FN) of Cashmere goats. There were obvious significance between BN and FN in different seasons. In telogen, BN and FN partitioning was 75.7% ± 0.62% and 24.3% ± 0.62%, respectively. Whereas, it changed to 66.6% ± 2.2% and 33.4% ± 2.2% in anagen. BN partitioning decreased when the season changed from telogen to anagen, while FN partitioning increased, which indicated that more nitrogen substance was partitioned to body growth in telogen, and more nitrogen substance was distribute to cashmere growth in anagen. These transformation were related to the changing of photoperiod and some hormones, such as melatonin (MT), prolactin (PRL) and IGF-I. It could be concluded that tritiated water dilution technique can be used to detect body protein content as well as BN, combining general digestive and metabolism experiment, FN partitoning can be determined. BN and FN partitoning varied with the season in cashmere goats because of hormones changing. (authors)

  16. Cardiac output determined by echocardiography in patients with cirrhosis: comparison with the indicator dilution technique

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Møller, Søren; Bendtsen, Flemming

    2003-01-01

    technique (CO(I)). METHODS: Twelve patients with cirrhosis were studied. CO(d) was measured as the spatial mean velocity of the left ventricular outflow tract, multiplied by the cross-sectional area and the heart rate. CO(I) was determined by the standard indicator dilution technique after injection of 125I...... albumin and 99mTc albumin into the right atrium and subsequent sampling from the femoral artery. RESULTS: The mean CO(d) and CO(I) were similar (7.20 vs 7.15 l/min, NS). A highly significant correlation was present between CO(d) and CO(I) (r = 0.86, P

  17. Determination of total uranium by mass spectrometry utilizing the isotopic dilution technique

    International Nuclear Information System (INIS)

    Cretella, R.F.; Noutary, C.J.; Servant, R.E.

    1981-01-01

    The isotopic dilution associated to mass spectrometry is a high-sensitivity technique that allows to work with microquantities of the sample, making it possible to analize the content in highly radioactive solutions with excellent accuracy and minimum risk. The proposed technique is described and its results are discussed through the analysis of: 1) A synthetic sample that simulates dissolved spent fuel elements; 2) Uranium dioxide of nuclear purity and 3) Uranium concentrate. 233 U(ORNL) was employed as a tracer and a Nuclide 12-90-SU mass spectrometer of simple magnetic focus as measurement instrument. The accuracy reached in the analyses is better than 0.5% with a reliability of 95%. The analysis of the errors shows that their main contributing source are the errors in the measurement of the isotopic ratios. (M.E.L.) [es

  18. The relation of plasma octopamine to hepatic encephalopathy studied with stable isotope dilution technique

    International Nuclear Information System (INIS)

    Zhang Jianhua

    1992-01-01

    In order to investigate the relationship between octopamine and hepatic encephalopathy, plasma octopamine content of normal adults and hepatic patients (compensated or de-compensated cirrhotic, patients with encephalopathy) were determined with isotope dilution and GCMS technique, 200 ng of [1, 1-D]-octopamine was added to each sample as internal standard. After the de-proteinized plasma was subjected to cation exchange chromatography, the amine fraction was derivatized with PFP and analyzed with GCMS using the selected ion monitoring technique. The result showed that the level of plasma octopamine was significantly elevated in patients with encephalopathy. Since this method is sensitive and specific, it is readily applicable to the analysis of a few nano grams of octopamine

  19. Estimation of endogenous faecal calcium in buffalo (BOS bubalis) by isotope dilution technique

    International Nuclear Information System (INIS)

    Singh, S.; Sareen, V.K.; Marwaha, S.R.; Sekhon, B.; Bhatia, I.S.

    1973-01-01

    Detailed investigations on the isotope-dilution technique for the estimation of endogenous faecal calcium were conducted with buffalo calves fed on growing ration. The ration consisted of wheat straw, green lucerne and concentrate mix. The endogenous faecal calcium was 3.71 g/day, which is 17.8 percent of the total faecal calcium. The apparent and true digestibilities of Ca were calculated as 51 and 60 percent respectively. The endogenous faecal calcium can be estimated in buffalo calves by giving single subcutaneous injection of Ca 45 and collecting blood samples on 12th and 21st days only, and representative sample from the faeces collected from 13th through 22nd day after the injection. (author)

  20. Study of ferrallitisation process in soil by application of isotopic dilution kinetic technique to iron

    International Nuclear Information System (INIS)

    Thomann, Christiane

    1978-01-01

    Isotopic dilution kinetic technique applied to iron may contribute to make clear the conditions of ''potential'' mobility of iron in soils, under the action of three factors: moisture, incubation period and organic matter imputs. Comparison between surface horizons of three tropical soils: leached ferruginous tropical soil, weakly ferrallitic red soil and ferrallitic soil shows that in the ferrallitisation process, weakly ferrallitic soil would take place between the two other types of soils with a maximum mobility of iron. This mobility decreases when organic matter rate decreases leading then to ''beige'' soil (ferruginous leached tropical soil), and when hydroxide rate increases, which leads to ferrallitic soil. In podzol (A 1 horizon), for the same rate of organic matter, potential mobility of iron is higher than in ferallitic soil, because it contains ten times more free iron than the podzol [fr

  1. Phosphorus Use Efficiency by Brazilian Common Bean Genotypes Assessed by the {sup 32}P Dilution Technique

    Energy Technology Data Exchange (ETDEWEB)

    Franzini, V. I. [Brazilian Agricultural Research Corporation, EMBRAPA-Amazonia Oriental, Belem, PA (Brazil); Muraoka, T. [Center for Nuclear Energy in Agriculture, University of Sao Paulo, Piracicaba, SP (Brazil); Adu-Gyamfi, J. J [International Atomic Energy Agency, Vienna (Austria); Lynch, J. P. [Pennsylvania State University, University Park, PA (United States)

    2013-11-15

    The objectives of this work were to identify the most efficient common bean (Phaseolus vulgaris L.) genotypes on phosphorus (P) utilization, and verify if P from the seed affects the classification of common bean genotypes on P uptake efficiency when the {sup 32}P isotopic dilution technique is used. The experiment was conducted in a greenhouse, and plants were grown in pots with surface samples of a dystrophic Typic Haplustox. The treatments consisted of 50 common bean genotypes and two standard plant species, efficient or inefficient in P uptake. The results were assessed through correlation and cluster analysis (multivariate). Sangue de Boi, Rosinha, Thayu, Grafite, Horizonte, Pioneiro and Jalo Precoce common bean genotypes were the most efficient on P uptake, and Carioca 80, CNF 10, Perola, IAPAR 31, Roxao EEP, Apore, Pioneiro, Pontal, Timbo and Ruda were the most efficient in P utilization. The P derived from seed influences the identification of common bean genotypes for P uptake efficiency. (author)

  2. Vitamin A equivalency and apparent absorption of ß-carotene in ileostomy subjects using a dual-isotope dilution technique

    NARCIS (Netherlands)

    Bouwman, C.A.; Naber, T.H.J.; Breemen, van R.B.; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.M.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of ß-carotene in two diets using a dual-isotope dilution technique and the apparent ß-carotene absorption as measured by the oral–faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  3. Vitamin A equivalency and apparent absorption of beta-carotene in ileostomy subjects using a dual-isotope dilution technique.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; Naber, T.H.; Breemen, R.B. van; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of beta-carotene in two diets using a dual-isotope dilution technique and the apparent beta-carotene absorption as measured by the oral-faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled,

  4. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  5. Application of the mass spectrometry-isotope dilution technique for the determination of uranium contents in rocks

    International Nuclear Information System (INIS)

    Kakazu, M.H.; Iyer, S.S.

    1980-01-01

    Application of the spectrometric isotope dilution technique for the accurate determination of parts per million range of uranium in rock samples is described. The various aspects of the method like sample dissolution, ion exchange separation, mass spectrometric procedures are discussed. A single filament ionization source was employed for the isotope analysis. A carbon reduction method was used to reduce uranium oxide ions to uranium metal ions. The tracer solution for isotope dilution was prepared from National Bureau of Standards uranium isotopic Standard NBS U-970. Uranium contents are meassured for nine rock samples and the values obtained are compared with the uranium values measured by others workers. Errors caused in the uranium determination due to sample splitting problems as well as the incomplete acid digestion of the samples are discussed. (Author) [pt

  6. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Pak, Yong Nam

    2016-01-01

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA

  7. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Pak, Yong Nam [Dept. of Chemistry Education, Korea National University of Education, Cheongju (Korea, Republic of)

    2016-11-15

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA.

  8. Radioisotope dilution technique for determination of vitamin B12 in foods

    International Nuclear Information System (INIS)

    Casey, P.J.; Speckman, K.R.; Ebert, F.J.; Hobbs, W.E.

    1982-01-01

    A radioisotope dilution (RID) method for the determination of vitamin B 12 is presented. The method combines a standard extraction procedure (AOAC 43.108, 12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products. Recovery studies on both groups yielded average recoveries of 98.1 and 95.8%, respectively. Reproducibility data generated from replicate analysis on both groups gave a relative standard deviation of 6.9% for the fortified group and 9.2% for the unfortified group. For the samples studied, the mean vitamin B 12 content determined by the RID method was 8.01 μ/100 g vs a mean of 7.54 μg/100 g by the AOAC microbiological method; the correlation coefficient was r = 0.983

  9. Uranium determination in sea water using the isotopic dilution technique and HR-ICPMS

    International Nuclear Information System (INIS)

    Pereira, Marcio Henrique da Costa; Sarkis, Jorge Eduardo de Souza; Hortellani, Marcos Antonio; Nascimento, Marcos R.L.

    2009-01-01

    In this work, the uranium total and the isotopic composition in seawater were calculated using the isotopic dilution applied to the mass spectrometry. The used tracer was a 233 U solution . Near 99 % of the present salts in the matrix were separated by evaporation up to the saturation point. The uranium present in aqueous phase was separated from the matrix through the ion exchange chromatography using the strong Dowex 1 x 8 200-400 mesh anionic resin in chloridric medium 12 M. The analyses were performed in a high resolution mass spectrometer with plasma inductively coupled source. The method validation was done using the seawater standard CASS-4 (Near shore Seawater Reference Material for Trace metals) produced by the NRC C. The procedure allowed to obtain the fractions exempt of salts, having as consequence a greater stability in the analytical signal, and a rise in the instrumental revenue for a great number of samples. The uranium found in the samples was present in levels considered naturals and were obtained with a precision near 2 %

  10. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  11. Optimization in radiological protection; Otimizacao em radioprotecao

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Perez, Clarice de Freitas

    1996-07-01

    The optimization concept in radiation protection is, in its essence, practical. In each aspect that we deal with the man, it is necessary to take frequent decisions such as: what is the protection level to be pursued, since the protection levels under consideration provide doses lower than the appropriate annual limits. The optimization gives a basic framework of the minding that is appropriate to conduct to a balance kind of the resources available for the protection and protection level obtained against a multitude of factors and constrains in a manner to obtain the best result. In this work, was performed the optimization, from the radiation protection point of view, of a facility project who enclose two shielded hot cells where will be handled UO{sub 2} small plate with 50% of U-235 burn-up, irradiated in the research swimming pool reactor, IEA-R1. To obtain this goal were specified the relevant factors and criteria, were applied the main techniques used in a decision-making in radiological protection, presently adopted and was performed a sensibility study of the factors and criteria used in this work. In order to obtain a greater agility in applying the techniques for decision-making was developed a micro computer program. (author)

  12. Genetic variability in dinitrogen fixation between cowpea [Vigna unguiculata (L.) Walp] cultivars determined using the nitrogen-15 isotope dilution technique

    International Nuclear Information System (INIS)

    Ndiaye, M.A.F.; Spencer, M.M.; Gueye, M.

    2000-01-01

    N fixed in 16 cultivars of cowpea [Vigna unguiculata (L.) Walp] inoculated with effective Bradyrhizobium strains collected from the West African MIRCEN culture collection was measured by 15N isotope dilution technique. In all plant parts, significant differences in the percentage of N derived from the atmosphere (%Ndfa) and the amount of Ndfa occurred between the cultivars. Ndoute variety exhibited the highest %Ndfa (74.33% in shoots; 60.90% in roots) and accumulated more fixed N (960 mg N plant–1 and 38 mg N plant–1 in shoots and roots, respectively). Therefore this cultivar should be selected as the highest N-fixing cowpea cultivar. It also should be used in a breeding programme to contribute to the development of cultivars that could stimulate an intensive use of cowpea in many different cropping systems in Africa with a view to maintaining soil fertility. (Authors)

  13. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; West, C.E.; Breemen, R.B. van; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.; Lieshout, M. van; Russel, F.G.M.; Schaafsma, G.; Naber, A.H.J.

    2009-01-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted

  14. Vitamin A equivalency of ß-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect

    NARCIS (Netherlands)

    Bouwman, C.A.; West, C.E.; Breemen, van R.B.; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.M.; Lieshout, van M.; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.J.

    2009-01-01

    Data on the vitamin A equivalency of ß-carotene in food are inconsistent. We quantified the vitamin A equivalency (¿g) of ß-carotene in two diets using the dual-isotope dilution technique and the oral¿faecal balance technique. A diet-controlled, cross-over intervention study was conducted in

  15. Phosphorus Use Efficiency by Brazilian Upland Rice Genotypes Evaluated by the {sup 32}P Dilution Technique

    Energy Technology Data Exchange (ETDEWEB)

    Franzini, V. I.; Mendes, F. L. [Brazilian Agricultural Research Corporation, EMBRAPA-Amazonia Oriental, Belem, PA (Brazil); Muraoka, T.; Da Silva, E. C. [Center for Nuclear Energy in Agriculture, University of Sao Paulo, Piracicaba, SP (Brazil); Adu-Gyamfi, J. J. [Soil and Water Management and Crop Nutrition Laboratory, International Atomic Energy Agency, Vienna (Austria)

    2013-11-15

    The objectives of this work were to identify the most efficient upland rice genotypes in phosphorus (P) utilization, and to verify if P from the seed affects the classification of upland rice genotypes on P uptake efficiency. The experiment was conducted in a greenhouse of the Center for Nuclear Energy in Agriculture (CENA/USP), Piracicaba, Sao Paulo, Brazil, using the {sup 32}P isotope technique, and plants were grown in pots with samples of dystrophic Typic Haplustox (Oxisol). The experimental design was completely randomized with four replications. The treatments consisted of 47 upland rice genotypes and two standard plant species, efficient or inefficient in P uptake. The results were assessed through correlation and cluster analysis (multivariate). The Carisma upland rice genotype was the most efficient in P uptake, and Caripuna was the most efficient on P utilization. The P derived from seed does not influence the identification of upland rice genotypes in P uptake efficiency. (author)

  16. In vivo measurement of myocardial protein turnover using an indicator dilution technique

    International Nuclear Information System (INIS)

    Revkin, J.H.; Young, L.H.; Stirewalt, W.S.; Dahl, D.M.; Gelfand, R.A.; Zaret, B.L.; Barrett, E.J.

    1990-01-01

    We applied a nondestructive tracer technique, previously developed for measuring skeletal muscle protein turnover, to the measurement of myocardial protein turnover in vivo. During a continuous infusion of L-[ring-2,6-3H]phenylalanine to anesthetized, overnight-fasted dogs, we measured the uptake of radiolabeled phenylalanine from plasma and the release of unlabeled phenylalanine from myocardial proteolysis using arterial and coronary sinus catheterization and analytic methods previously applied to skeletal muscle. Using these measurements, together with a model of myocardial protein synthesis that assumes rapid equilibration of tracer specific activity between myocardial phenylalanyl-tRNA and circulating phenylalanine, we estimated the rates of heart protein synthesis and degradation. The rate of heart protein synthesis was also estimated directly from the incorporation of labeled phenylalanine into tissue protein. The use of [3H]phenylalanine was compared with L-[1-14C]leucine in the measurement of heart protein turnover in dogs given simultaneous infusion of both tracers. Leucine uptake and release by the myocardium exceeded that of phenylalanine by 3.1 +/- 0.4- and 1.7 +/- 0.3-fold, respectively, consistent with leucine's 2.4-fold greater abundance in heart protein and its metabolism via other pathways. Phenylalanine is the preferred tracer for use with this method because of its limited metabolic fate in muscle. One theoretical limitation to the method, slow equilibration of circulating labeled phenylalanine with myocardial phenylalanyl-tRNA, was resolved by comparison of these specific activities after a 30-minute infusion of labeled phenylalanine in the rat. A second, empirical limitation involves precision in the measurement of the small decrements in phenylalanine specific activity that occur with each pass of blood through the coronary circulation

  17. Hemodiafiltration using pre-dilutional on-line citrate dialysate: A new technique for regional citrate anticoagulation: A feasibility study

    Directory of Open Access Journals (Sweden)

    Radhouane Bousselmi

    2015-01-01

    Full Text Available A prospective, observational, feasibility study was carried out on four patients with end-stage renal failure undergoing bicarbonate hemodialysis to study the feasibility of an on-line hemodiafiltration technique using a citrate dialysate with pre-dilutional infusion of citrate as a technique for regional citrate anticoagulation. All patients had contraindication to systemic heparin anticoagulation. The dialysis technique consisted of an on-line hemodiafiltration with a citrate dialysate without calcium using a Fresenius 4008S dialysis machine and Fresenius Polysulfone F60 dialyzers. The infusion solution was procured directly from the dialysate and was infused into the arterial line. To avoid the risk of hypocalcemia, calcium gluconate was infused to the venous return line. The study was carried out in two stages. During the first stage, the citrate infusion rate was 80 mL/min and the calcium infusion rate was 9 mmol/h. At the second stage, the rates were 100 mL/min and 11 mmol/h, respectively. The primary endpoint of this study was the incidence of thrombosis in the extracorporeal blood circuit and/or the dialyzer. A total of 78 sessions were conducted. All the sessions were well tolerated clinically and there were no major incidents in any of the four patients. At the first stage of the study, there were five incidences of small clots in the venous blood chamber, an incidence of extracorporeal blood circuit thrombosis of 12.5%. At the second stage of the study, no cases of extracorporeal blood circuit or dialyzer thrombosis were noted. Hemodiafiltration with on-line citrate dialysate infusion to the arterial line is safe and allows an effective regional anticoagulation of the extracorporeal blood circuit without the need for systemic anticoagulation.

  18. The use of stable isotope dilution technique to determine the amount of breast milk consumed by infants

    International Nuclear Information System (INIS)

    Sajet, A. S.

    2011-01-01

    Exclusive breast feeding for six months to an infant, followed by the introduction of complementary food and continued with breast feeding is believed to be an optimal way of infants nutrition. There is a shortage in information about the amount of milk obtained from the infant's mother at least partially due to the difficulties associated with quantification of breast milk intake. The old technique, which depends on how the weight of the baby before and after breast feeding from mother, takes time and may be disturbing to the natural feeding pattern. It was possible to overcome these difficulties by using stable isotopes consumed by mother as D ose of deuterium oxide to mother i n particular dilution dose to mother and then move the dose from mother to baby through breast milk and this can calculate the total volume of breast milk consumed by the infant within 14 days since the dose oxide of deuterium consumed at first day. Dose of deuterium oxide to mother can also help to find out if there were any further quantity of water entering the child's body except breast milk, determine body composition for mother and infant, monitor the effects of programs strengthening food for pregnant mothers and lactating women in terms of quantity and quality of milk overnight, in addition to evaluating the effectiveness of programs to strengthen children's food. (author)

  19. Multiple-indicator dilution technique for characterization of normal and retrograde flow in once-through rat liver perfusions

    International Nuclear Information System (INIS)

    St-Pierre, M.V.; Schwab, A.J.; Goresky, C.A.; Lee, W.F.; Pang, K.S.

    1989-01-01

    The technique of normal and retrograde rat liver perfusion has been widely used to probe zonal differences in drug-metabolizing activities. The validity of this approach mandates the same tissue spaces being accessed by substrates during both normal and retrograde perfusions. Using the multiple-indicator dilution technique, we presently examine the extent to which retrograde perfusion alters the spaces accessible to noneliminated references. A bolus dose of 51Cr-labeled red blood cells, 125I-albumin, 14C-sucrose and 3H2O was injected into the portal (normal) or hepatic (retrograde) vein of rat livers perfused at 10 ml per min per liver. The outflow perfusate was serially collected over 220 sec to characterize the transit times and the distribution spaces of the labels. During retrograde perfusion, red blood cells, albumin and sucrose profiles peaked later and lower than during normal perfusion, whereas the water curves were similar. The transit times of red blood cells, albumin and sucrose were longer (p less than 0.005), whereas those for water did not change. Consequently, retrograde flow resulted in significantly larger sinusoidal blood volumes (45%), albumin Disse space (42%) and sucrose Disse space (25%) than during normal flow, whereas the distribution spaces for total and intracellular water remained unaltered. The distension of the vascular tree was confirmed by electron microscopy, by which occasional isolated foci of widened intercellular recesses and spaces of Disse were observed. Cellular ultrastructure was otherwise unchanged, and there was no difference found between normal and retrograde perfusion for bile flow rates, AST release, perfusion pressure, oxygen consumption and metabolic removal of ethanol, a substrate with flow-limited distribution, which equilibrates rapidly with cell water (hepatic extraction ratios were virtually identical: normal vs. retrograde, 0.50 vs. 0.48 at 6 to 7.4 mM input concentration)

  20. A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients

    Czech Academy of Sciences Publication Activity Database

    Chan, C.; Smith, D.; Španěl, Patrik; McIntyre, Ch. W.; Davies, S. J.

    2008-01-01

    Roč. 23, č. 6 (2008), s. 2064-2070 ISSN 0931-0509 Institutional research plan: CEZ:AV0Z40400503 Keywords : flowing after-glow mass spectrometer (FA-MS) * body composition * deuterium dilution Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.568, year: 2008

  1. Effects of the technique of cryopreservation and dilution/centrifugation after thawing on the motility and vitality of spermatozoa of oligoasthenozoospermic men

    Directory of Open Access Journals (Sweden)

    Esteves Sandro C.

    2003-01-01

    Full Text Available OBJECTIVE: Comparing in human semen samples with low initial quality, the effects of 2 techniques of cryopreservation and dilution/centrifugation after thawing on the spermatic motility and vitality. MATERIALS AND METHODS: Semen samples from 15 oligo and/or asthenozoospermic individuals assisted in the infertility sector of a tertiary hospital were obtained through masturbation. The samples were divided into 2 portions of equal volume, and diluted (1:1; v/v with the cryoprotector containing glycerol (Test yolk buffer. One portion was frozen through the technique of liquid nitrogen vapor with static phases (group I - GI, while the other was frozen through a programmable biological freezer with linear speed (Planer, Kryo 10, series III (group II - GII. The following parameters were assessed before freezing and after thawing: percentage of spermatozoa with progressive motility (Prog% and percentage of live spermatozoa (Vit%. After defrosting, Prog% was assessed before and after removal of cryoprotector diluent, in different time intervals (zero, 3 h, and 24 h. The statistical analysis has been accomplished by using the non-parametric tests of Wilcoxon and Friedman. RESULTS: There was significant reduction of Prog% and Vit% from before freezing to after defrosting in both groups, I and II (p < 0.001. Values of Prog% and Vit% were not statistically different between groups, after thawing. It has been observed a significant reduction in Prog% among portions frozen with the automated technique after dilution and centrifugation for removal of cryoprotector (p = 0.006. After cryoprotector removal, Prog% has been kept unaltered, in both groups, during the first 3 hours of incubation, although being superior in group I (p = 0,04. There was a significant decrease in Prog% after 24 hours of incubation, in both groups (p < 0,01. CONCLUSION: For human semen samples with low initial quality, freezing through vapor technique or through the automated technique

  2. Effects of the technique of cryopreservation and dilution/centrifugation after thawing on the motility and vitality of spermatozoa of oligoasthenozoospermic men.

    Science.gov (United States)

    Esteves, Sandro C; Spaine, Deborah M; Cedenho, Agnaldo P; Srougi, Miguel

    2003-01-01

    Comparing in human semen samples with low initial quality, the effects of 2 techniques of cryopreservation and dilution/centrifugation after thawing on the spermatic motility and vitality. Semen samples from 15 oligo and/or asthenozoospermic individuals assisted in the infertility sector of a tertiary hospital were obtained through masturbation. The samples were divided into 2 portions of equal volume, and diluted (1:1; v/v) with the cryoprotector containing glycerol (Test yolk buffer). One portion was frozen through the technique of liquid nitrogen vapor with static phases (group I - GI), while the other was frozen through a programmable biological freezer with linear speed (Planer, Kryo 10, series III) (group II - GII). The following parameters were assessed before freezing and after thawing: percentage of spermatozoa with progressive motility (Prog%) and percentage of live spermatozoa (Vit%). After defrosting, Prog% was assessed before and after removal of cryoprotector diluent, in different time intervals (zero, 3 h, and 24 h). The statistical analysis has been accomplished by using the non-parametric tests of Wilcoxon and Friedman. There was significant reduction of Prog% and Vit% from before freezing to after defrosting in both groups, I and II (p live spermatozoa with progressive motility. The effects of dilution and centrifugation to remove the cryoprotector had a negative impact only in samples frozen through the automated technique. In both techniques, progressive motility is kept constant during the first 3 hours after thawing and removal of the cryoprotector, but is drastically diminished by the end of an incubation period of 24 hours.

  3. A comparative study on the production rates of VFA and bacteria in the rumen of buffalo and goat estimated by isotope dilution technique

    International Nuclear Information System (INIS)

    Verma, D.N.; Mehra, U.R.; Singh, U.B.; Ranjhan, S.K.

    1977-01-01

    Digestibility trials were conducted on Murrah buffaloes and Barbari goats with rumen cannulae in the rumen to determine the digestibility of the feed constituents and the production rates of bacteria and total VFA were estimated in the rumen by isotope dilution technique. The bacterial cells growth in the rumen was more in goats than buffaloes when fed ad libitum and calculated on equal feed intake, where as, in buffaloes fed on restricted diet equal to the goats the production of bacteria and VFA were higher. Goats converted 54.04 percent of their dietary nitrogen into microbial nitrogen which was more than twice of buffaloes. (author)

  4. A New Flow Control Technique Using Diluted Epinephrine in the N-butyl-2-cyanoacrylate Embolization of Visceral Artery Pseudoaneurysms Secondary to Chronic Pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Yamagami, Takuji [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan); Takeuchi, Yoshito [National Cancer Center, Division of Diagnostic Radiology (Japan); Matsumoto, Tomohiro; Asai, Shunsuke; Masui, Koji [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Sato, Hideki [Japan Red Cross Kyoto Daiichi Hospital, Department of Gastroenterology (Japan); Taniguchi, Fumihiro [Japan Red Cross Kyoto Daiichi Hospital, Department of Surgery (Japan); Sato, Osamu [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan)

    2012-08-15

    Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.

  5. Application of the deuterated retinol dilution technique to detect changes in hepatic retinol reserves in infants who receive high dose vitamin A supplements

    International Nuclear Information System (INIS)

    Penny, M.; Lanata, C.; Butron, B.; Haskell, M.; Brown, K.

    1997-01-01

    The purpose of this pilot study is to determine whether the deuterated retinol dilution technique can detect changes in hepatic vitamin A reserves in Peruvian infants in response to supplementation with vitamin A palmitate. Approximately 40 infants, 9 months of age, will be recruited for the study and randomly assigned to four treatment groups. Hepatic vitamin A reserves will be estimated using the deuterated retinol dilution technique before and after administration of a single supplement containing either 0, 7.5, 15, or 30 mg RE as retinyl palmitate in corn oil. Mean hepatic vitamin A reserves will be calculated based on the plasma isotopic ratio of d4-retinol:retinol as per Furr, et. al. Hepatic vitamin A reserves will be compared within groups before and after supplementation, and among the four groups. The mean change in hepatic vitamin A reserves across the four treatment groups will be examined in relation to the amount of vitamin A supplement administered, using regression analysis. The results of the pilot study will provide information on the size and variation of hepatic vitamin A reserves in 9-month old Peruvian infants. This information will be useful for calculating samples sizes to evaluate vitamin A intervention strategies by estimating changes in hepatic vitamin A stores in this age group, using the DRD technique. (author)

  6. Application of the deuterated retinol dilution technique to detect changes in hepatic retinol reserves in infants who receive high dose vitamin A supplements

    Energy Technology Data Exchange (ETDEWEB)

    Penny, M; Lanata, C; Butron, B [Instituto de Investigacion Nutricional, Lima (Peru); Haskell, M; Brown, K [Programme in International Nutrition, Univ. of California, Davis, CA (United States)

    1998-12-31

    The purpose of this pilot study is to determine whether the deuterated retinol dilution technique can detect changes in hepatic vitamin A reserves in Peruvian infants in response to supplementation with vitamin A palmitate. Approximately 40 infants, 9 months of age, will be recruited for the study and randomly assigned to four treatment groups. Hepatic vitamin A reserves will be estimated using the deuterated retinol dilution technique before and after administration of a single supplement containing either 0, 7.5, 15, or 30 mg RE as retinyl palmitate in corn oil. Mean hepatic vitamin A reserves will be calculated based on the plasma isotopic ratio of d4-retinol:retinol as per Furr, et. al. Hepatic vitamin A reserves will be compared within groups before and after supplementation, and among the four groups. The mean change in hepatic vitamin A reserves across the four treatment groups will be examined in relation to the amount of vitamin A supplement administered, using regression analysis. The results of the pilot study will provide information on the size and variation of hepatic vitamin A reserves in 9-month old Peruvian infants. This information will be useful for calculating samples sizes to evaluate vitamin A intervention strategies by estimating changes in hepatic vitamin A stores in this age group, using the DRD technique. (author). 12 refs, 3 figs.

  7. Experimental substantiation of separation techniques of lead and uranium microamounts using isotopic dilution method as control method

    International Nuclear Information System (INIS)

    Agapova, A.A.; Shcherbinina, N.K.

    1983-01-01

    Methods,ensuring at low levels of contamination a high degree of lead and uranium microamount separation from solutions of geological samples, have been selected and subjected to the detailed testing. The method of isotope dilution, , combining high accuracy and sensitivity of determinations, is used as the main control methods, is used as the main control method. Using the method, processe es of uranium extpaction are traced, special attention is paid to the detailed description of lead extraction at all the stages of the methods selected. Opera ations of ion exchange for lead and uranium in microcolumns with the Bio-Rad r sin are considered, as well as operations of lead electrolytic separation. The chemical procedures suggested permit to solve one of the main methodical tasks f sample preparation, containing microgram amounts of lead and uranium, for high h-prcision measurement of their isotope composition using mass-spectrometric method

  8. Isotope dilution analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fudge, A.

    1978-12-15

    The following aspects of isotope dilution analysis are covered in this report: fundamental aspects of the technique; elements of interest in the nuclear field, choice and standardization of spike nuclide; pre-treatment to achieve isotopic exchange and chemical separation; sensitivity; selectivity; and accuracy.

  9. Dilution Confusion: Conventions for Defining a Dilution

    Science.gov (United States)

    Fishel, Laurence A.

    2010-01-01

    Two conventions for preparing dilutions are used in clinical laboratories. The first convention defines an "a:b" dilution as "a" volumes of solution A plus "b" volumes of solution B. The second convention defines an "a:b" dilution as "a" volumes of solution A diluted into a final volume of "b". Use of the incorrect dilution convention could affect…

  10. An Evaluation Method for the Suppression of Pathogenic Fusarium oxysporum by Soil Microorganisms Using the Dilution Plate Technique.

    Science.gov (United States)

    Mitsuboshi, Masahiro; Kioka, Yuuzou; Noguchi, Katsunori; Asakawa, Susumu

    2016-09-29

    Soil-borne diseases caused by pathogenic microorganisms are one of the main factors responsible for the decline in crop yields in farmlands. Pathogenic Fusarium oxysporum causes serious damage to various crops, and, thus, a feasible diagnostic method for soil-borne diseases is required. We herein examined a simple method to evaluate the suppressiveness of soil microorganisms against a pathogen by co-cultivating indigenous soil microorganisms and a pathogenic fungus (F. oxysporum f. sp. spinaciae). We inoculated F. oxysporum onto the center of agar medium plates mixed with a dilution series of a suspension of organic fertilizers or soil. After an approximately one-week cultivation, the growth degree of F. oxysporum was estimated based on the size of the colonies that formed on the plates. The growth degree of F. oxysporum significantly differed among the organic fertilizers tested, indicating the usefulness of the method for evaluating suppressiveness by organic fertilizers. Differences in the growth degrees of F. oxysporum were associated with the incidence of disease in spinach on soil treated with organic fertilizers and inoculated with a pathogenic F. oxysporum strain. These results suggested that this method provides some useful information on the suppressiveness of organic fertilizers and soil against Fusarium wilt.

  11. Development of isotope dilution-liquid chromatography/mass spectrometry combined with standard addition techniques for the accurate determination of tocopherols in infant formula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joonhee; Jang, Eun-Sil; Kim, Byungjoo, E-mail: byungjoo@kriss.re.kr

    2013-07-17

    Graphical abstract: -- Highlights: •ID-LC/MS method showed biased results for tocopherols analysis in infant formula. •H/D exchange of deuterated tocopherols in sample preparation was the source of bias. •Standard addition (SA)-ID-LC/MS was developed as an alternative to ID-LC/MS. •Details of calculation and uncertainty evaluation of the SA-IDMS were described. •SA-ID-LC/MS showed a higher-order metrological quality as a reference method. -- Abstract: During the development of isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) for tocopherol analysis in infant formula, biased measurement results were observed when deuterium-labeled tocopherols were used as internal standards. It turned out that the biases came from intermolecular H/D exchange and intramolecular H/D scrambling of internal standards in sample preparation processes. Degrees of H/D exchange and scrambling showed considerable dependence on sample matrix. Standard addition-isotope dilution mass spectrometry (SA-IDMS) based on LC/MS was developed in this study to overcome the shortcomings of using deuterium-labeled internal standards while the inherent advantage of isotope dilution techniques is utilized for the accurate recovery correction in sample preparation processes. Details of experimental scheme, calculation equation, and uncertainty evaluation scheme are described in this article. The proposed SA-IDMS method was applied to several infant formula samples to test its validity. The method was proven to have a higher-order metrological quality with providing very accurate and precise measurement results.

  12. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    2010-01-01

    The IAEA has fostered the more widespread use of a stable isotope technique to assess body composition in different population groups to address priority areas in public health nutrition in Member States. It has done this by supporting national and regional nutrition projects through its technical cooperation programme and coordinated research projects over many years. This publication was developed by an international group of experts to provide practical hands-on guidance in the use of this technique in settings where analysis of stable isotope ratios in biological samples is to be made by isotope ratio mass spectrometry. The publication is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical applications of state of the art methodologies to monitor changes in body composition can be found in IAEA Human Health Series No. 3, Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques

  13. The use of the 15N isotope dilution technique to estimate the contribution of associated biological nitrogen fixation to the nitrogen nutrition of Paspalum notatum cv. batatais

    International Nuclear Information System (INIS)

    Boddey, R.M.; Doebereiner, Johanna

    1983-01-01

    This paper reports the results of a field experiment to investigate the use of the 15 N-dilution technique to measure the contribution of biological N 2 fixation to the N nutrition of the batatais cultivar of Paspalum notatum. The pensacola cultivar of this grass supports little associated N 2 fixation as evidenced by the low associated C 2 H 2 reduction activity and was thus used as a nonfixing control plant. The grasses were grown in 60-cm diameter concrete cylinders sunk into the soil, and the effects of four different addition rates of labelled nitrogen (NH 4 ) 2 SO 4 , were investigated. The data from seven harvests clearly demonstrated that there was a significant input of plant associated N 2 fixation to the nutrition of the batatais cultivar amounting to approximately 20 kg N ha -1 year -1 . Problems associated with the conduct of such isotope dilution experiments are discussed including the importance of using nonfixing control plants of similar growth habit, the advantages and disadvantages of growing the plants in cylinders as opposed to field plots, and the various methods of application of labelled N fertilizer

  14. Introduction to body composition assessment using the deuterium dilution technique with analysis of saliva samples by fourier transform infrared spectrometry

    International Nuclear Information System (INIS)

    2010-01-01

    For many years, the IAEA has fostered the more widespread use of stable isotope techniques to assess body composition in different population groups to address priority areas in public health nutrition in Member States. The objective is to support national and regional nutrition projects through both the IAEA's technical cooperation programme and its coordinated research projects. In particular, during the last few years, the increased access to analyses of deuterium enrichment by Fourier transform infrared (FTIR) spectrometry has increased the application of this technique in Africa, Asia and Latin America. This publication was developed by an international group of experts to provide practical, hands-on guidance in the use of this technique in settings where the analysis of deuterium enrichment in saliva samples will be made by FTIR. It is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical application of state of the art methodologies to monitor changes in body composition can be found in an IAEA publication entitled Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques (IAEA Human Health Series No. 3)

  15. Phosphorus availability to ryegrass from urban sewage sludges assessed by isotopic labeling and dilution technique, effect of irradiation

    International Nuclear Information System (INIS)

    El-Motaium, R.A.; Morel, C.

    2007-01-01

    Urban sewage sludge are widely used as alternative P input because of their high P content. Irradiation of sewage sludge is developed in Egypt to make safe spreading of sludge on agricultural fields. Five sludges were sampled from representative urban wastewater treatment plants located in Cairo, Egypt. Sub samples were irradiated using gamma radiation at 6 KGy dose. A pot experiment was conducted under plastic greenhouse using sandy P-deficient soil. The soil was homogeneously labelled with a radioactive solution of carrier-free 32 PO 4 (about 3 MBq kg / soil) to determine the contribution of the different sources of P in plant nutrition. Sludges were applied at 50 mg P/ kg soil. In addition, a control treatment was also carried out to analyze sludge P availability in comparison to a water soluble mineral fertilizer, i.e. 50 mg P/kg soil was applied as commercial monocalcium phosphate (SSP). A reference treatment was included without any P application but the radioactive solution was added. One gram of ryegrass seeds (Lolium multiflorium) was sown in each pot. The aerial parts of the ryegrass were harvested four times, every 3 weeks. Analysis of all harvests included 32 P and total P content was used to determine the respective contribution of soil and sludge to plant P nutrition and the plant available P (L value) using the isotopic dilution principle. The ratio of radioactive P to non-radioactive P, i.e. isotopic composition, was calculated. The total P content in the different urban sewage sludge was ranged from 6.2 to 13.8 g P/ kg and affected by irradiation. Because the soil was extremely P deficient (L value=0.3 mg P/ kg soil), P derived from seeds represented 99% of the P taken up when no P was applied and 87% when applying 50 mg P-SSP/ kg. After correcting the contribution of ryegrass seeds, sludge P contributed by 98% to plant nutrition and 7.2% of the applied P was recovered. The sludge type and irradiation factors did not significantly affect sludge P

  16. Vitamin A metabolism, kinetic behavior and utilization: Rationale for the continued development and use of an isotope dilution technique for assessing vitamin A stores in human populations

    International Nuclear Information System (INIS)

    Green, M.H.

    1997-01-01

    The paper discusses the applicability of isotope dilution method in general and oral isotope dilution in particular to the assessment of vitamin A status in humans. It also highlights some aspects of vitamin A intake and metabolism as related to isotope dilution method. Areas of methodological research and development in vitamin A research are also proposed

  17. Study of leakages at dam sites in fractured rocks with the aid of the borehole dilution technique

    International Nuclear Information System (INIS)

    Ozbek, E.

    1978-02-01

    The connection between springs which occurred after the impoundment of Keban Lake and the lake was proved by tritium measurements. By additional application of single borehole techniques using radioisotopes as tracers it was possible to localize solution channels in the karstic aquifer as preferential paths for the water movement

  18. A simplification of the deuterium oxide dilution technique using FT-IR analysis of plasma, for estimating piglet milk intake

    International Nuclear Information System (INIS)

    Glencross, B.D.; Tuckey, R.C.; Hartmann, P.E.; Mullan, B.P.

    1997-01-01

    Previous studies estimating milk intake using deuterium oxide (D 2 O) as a tracer have required sublimation of the sample fluid (usually plasma) to remove solids and retrieve total water. This procedure has been simplified by directly measuring the D 2 O content of plasma with a Fourier transform-infrared (FT-IR) spectrometer, removing the requirement for sample sublimation. Comparisons of samples that were split and then analysed as water of sublimation and as total plasma were performed. It was found that the direct analysis of the plasma could be achieved without a loss in fidelity of the results (sublimated v. plasma, r 2 = 0.976; n = 26). Linearity of assay standards was very high (r 2 > 0.997). The modified technique was used to determine the milk intake by piglets from litters of 7 sows during established lactation (Days 10-15). Water turnover (WTO) was shown to be the primary point by which differences in the piglet milk intakes were influenced. Differences in the milk composition had minimal effect on the milk intake determinations. Milk intake by each piglet was shown to be strongly correlated to piglet growth (r 2 = 0.59, P 2 = 0.84, P < 0.01). Copyright (1997) CSIRO Australia

  19. performance of sorghum grown on a salt affected soil manured with dhaincha plant residues using a 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Al-Ain, F.; Razok, A.; Al-Shamma, M.

    2008-01-01

    A field experiment was conducted on a salt-affected soil to determine the effect of application of three types of Dhaincha (Sesbania aculeata pers.) residues (R, roots; L, shoots; L+R, shoots plus roots) of on the performance of sorghum (Sorghum bicolor L.) using the indirect 15 N isotopic dilution technique. Results indicated that Sesbania residues (L and L+R), used as green manures significantly increased grain yield, dry matter production, N uptake, and water use efficiency of sorghum. Percentages of N derived from residues (%Ndfr) in sorghum ranged from 6.4 to 28%. The N recoveries in sorghum were 52, 19. and 19.7% of the total amount contained in Sesbania roots, shoots and roots plus shoots, respectively. The beneficial effects of Sesbania residues are attributed not only to the additional N availability to the plants, but also to effects on the enhancement of soil N uptake, particularly in the L+R treatment. The findings suggest that the use of Sesbania aculeata residues, as a green manure, can provide a substantial portion of total N in sorghum. In addition, the use of Sesbania green manure in salt-affected soils, as a bio-reclaiming material, can be a promising approach for enhancing plant growth on a sustainable basis. (author)

  20. Evaluation of the Antibacterial and Antifungal Properties of Phragmanthera capitata (Sprengel Balle (Loranthaceae, a Mistletoe Growing on Rubber Tree, Using the Dilution Techniques

    Directory of Open Access Journals (Sweden)

    Franklin Uangbaoje Ohikhena

    2017-01-01

    Full Text Available The alarming increase in multidrug resistance of pathogenic microorganisms to conventional drugs in recent years has prompted the search for new leads in alternative remedies in natural products. Hence, this study was aimed at evaluating the antimicrobial properties of Phragmanthera capitata, a parasitic mistletoe growing on rubber trees. The in vitro antimicrobial activities of the acetone, methanol, ethanol, and aqueous extracts were investigated using five gram-negative and five gram-positive bacteria and four fungi. A 96-well resazurin broth and agar dilution techniques were used for the determination of the Minimum Inhibitory and Bactericidal Concentrations. The antibacterial activity of the organic extracts had comparative effects on all the bacteria with a MIC of 1.25 to 5 mg/mL and MBC of 2.5 to 10 mg/mL. However, the acetone extract showed higher bactericidal effect while the aqueous extract was not active. The organic solvent extracts also showed antifungal activities on two of the fungi with a MIC of 1.25 mg/mL to 10 mg/mL. However, the aqueous extract had the highest activity inhibiting all the fungi with a MIC of ≤0.3125 to 1.25 mg/mL. The study supports the ethnomedicinal claims of P. capitata as a remedy for the diseases/infections caused by these organisms.

  1. N fixation and transfer in Maize/Cowpea and Sorghum/Cowpea inter cropping systems as determined by N-15 isotope dilution technique

    International Nuclear Information System (INIS)

    Dayatilake, G.A.; Subasinghe, S.; Senaratne, R.

    2000-01-01

    N fixation and transfer in maize/cowpea and sorghum/cowpea intercropping systems, as determined by N-15 dilution technique was studied in two field trials conducted at Bata-atha, in the dry zone of Sri Lanka. Two cvs. of cowpea i.e; Bombay and MI-35 were used in maize/cowpea intercropping system, with following combinations of treatments; maize/Bombay, maize/MI-35, Bombay (monocrop), MI-35 (monocrop) and maize (monocrop). A similar set of treatments was used in sorghum/cowpea intercropping system also. The N-15 atom excess, percentage Ndfa, total amount of N fixed, N yield and the total dry matter production were estimated. Maize/cowpea intercropping resulted in an increase in total dry matter production and total N yield compared to monocrop treatment. However the percentage Ndfa and total N fixed showed a decrease compared to monocrop stand. The percentage Ndfa was 60-65 percent monocrop while the same was 45-50 percent in intercropped treatments

  2. Mechanistic model to predict colostrum intake based on deuterium oxide dilution technique data and impact of gestation and prefarrowing diets on piglet intake and sow yield of colostrum

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Flummer, Christine; Hurley, W L

    2014-01-01

    The aims of the present study were to quantify colostrum intake (CI) of piglets using the D2O dilution technique, to develop a mechanistic model to predict CI, to compare these data with CI predicted by a previous empirical predictive model developed for bottle-fed piglets, and to study how...... composition of diets fed to gestating sows affected piglet CI, sow colostrum yield (CY), and colostrum composition. In total, 240 piglets from 40 litters were enriched with D2O. The CI measured by D2O from birth until 24 h after the birth of first-born piglet was on average 443 g (SD 151). Based on measured...... CI, a mechanistic model to predict CI was developed using piglet characteristics (24-h weight gain [WG; g], BW at birth [BWB; kg], and duration of CI [D; min]: CI, g = –106 + 2.26 WG + 200 BWB + 0.111 D – 1,414 WG/D + 0.0182 WG/BWB (R2 = 0.944). This model was used to predict the CI for all colostrum...

  3. Gas chromatography/ion trap mass spectrometry applied for the analysis of triazine herbicides in environmental waters by an isotope dilution technique

    International Nuclear Information System (INIS)

    Cai Zongwei; Wang Dongli; Ma, W.T.

    2004-01-01

    A gas chromatography/ion trap mass spectrometry method was developed for the analysis of simazine, atrazine, cyanazine, as well as the degradation products of atrazine, such as deethylatrazine and deisopropylatrazine in environmental water samples. Isotope dilution technique was applied for the quantitative analysis of atrazine in water at low ng/l levels. One liter of water sample spiked with stable isotope internal standard atrazine-d 5 was extracted with a C 18 solid-phase extraction cartridge. The analysis was performed on an ion trap mass spectrometer operated in MS/MS method. The extraction recoveries were in the range of 83-94% for the triazine herbicides in water at the concentrations of 24, 200, and 1000 ng/l, while poor recoveries were obtained for the degradation products of atrazine. The relative standard deviation (R.S.D.) were within the range of 3.2-16.1%. The detection limits of the method were between 0.75 and 12 ng/l when 1 l of water was analyzed. The method was successfully applied to analyze environmental water samples collected from a reservoir and a river in Hong Kong for atrazine detected at concentrations between 3.4 and 26 ng/l

  4. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    Science.gov (United States)

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Application of the Particle Swarm Optimization (PSO) technique to the thermal-hydraulics project of a PWR reactor core in reduced scale; Aplicacao da tecnica de otimizacao por enxame de particulas no projeto termo-hidraulico em escala reduzida do nucleo de um reator PWR

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Carlos Alberto de Souza

    2008-09-15

    The reduced scale models design have been employed by engineers from several different industries fields such as offshore, spatial, oil extraction, nuclear industries and others. Reduced scale models are used in experiments because they are economically attractive than its own prototype (real scale) because in many cases they are cheaper than a real scale one and most of time they are also easier to build providing a way to lead the real scale design allowing indirect investigations and analysis to the real scale system (prototype). A reduced scale model (or experiment) must be able to represent all physical phenomena that occurs and further will do in the real scale one under operational conditions, e.g., in this case the reduced scale model is called similar. There are some different methods to design a reduced scale model and from those two are basic: the empiric method based on the expert's skill to determine which physical measures are relevant to the desired model; and the differential equation method that is based on a mathematical description of the prototype (real scale system) to model. Applying a mathematical technique to the differential equation that describes the prototype then highlighting the relevant physical measures so the reduced scale model design problem may be treated as an optimization problem. Many optimization techniques as Genetic Algorithm (GA), for example, have been developed to solve this class of problems and have also been applied to the reduced scale model design problem as well. In this work, Particle Swarm Optimization (PSO) technique is investigated as an alternative optimization tool for such problem. In this investigation a computational approach, based on particle swarm optimization technique (PSO), is used to perform a reduced scale two loop Pressurized Water Reactor (PWR) core, considering 100% of nominal power operation on a forced flow cooling circulation and non-accidental operating conditions. A performance

  6. Effect of time course application of nitrogen fertilizer on the N-fertilizer use efficiency, lint properties and seed cotton yield using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Janat, M.; Khalifa, Kh

    2001-12-01

    Field experiment was carried out at Der El-Hajar research station during 1998 growing season to evaluate the effect of time course application of nitrogen fertilizer on N-recovery, seed cotton yield and lint properties using 15 N isotope dilution technique. Aleppo 40 variety was tested, irrigation scheduling was set up at 80% of field capacity. Phosphorus fertilizer was applied as TSP 46% before planting at a rate of 180 kg/ha. N fertilizer was applied as urea (46%) in four different applications follows: one application 180 kg N/ha before planting (T1), two split application 180 (90 + 90) kg N/ha (T2), three equally split applications 180 (60 + 60 + 60) kg N/ha (T3), and four equally split applications 180 (45 + 45 + 45 + 45) kg N/ha (T4). Labeled N-fertilizer (5.09 a.e%) was also applied as urea 46% to the subplots (1.0 m 2 each) of the corresponding treatments. All agricultural practices were carried out as the common practices locally employed. Soil samples were analyzed for CEC, ph, EC, OM, total N, available P, and CaCO 3 as outlined by our laboratory standard procedure. Plant samples were collected at physiological maturity and analyzed for 15 N enrichment to assess N recovery. Lint samples were analyzed for lint properties. the results showed no significant effect of the nitrogen fertilizer time course application on the tested parameters such as dry matter production, seed cotton yield, N uptake and lint properties. on the other hand the T2, T3 and T4 treatments where shown to have a positive significant response toward time course application relative to T1 treatment. (authors)

  7. Quantitative assessment of breastfeeding practices and determination of the quantity of maternal milk consumed by infants aged up to 6 months using isotope dilution technique

    International Nuclear Information System (INIS)

    El Haloui, Noureddine; El Manchawy, Imane; Zahrou, Fatima-Ezzahra; El Hamdouchi, Asmaa; Aguenaou, Hassan; Rjimati, El Arbi

    2014-01-01

    Full text: Aims: 1- Determination of the quantity of maternal milk consumed using isotope dilution technique. 2-Determination of zinc content of maternal milk and blood. Methods: This study was carried out in Hôpital d’Enfant in Rabat on 32 women of whom 12 were paired to small birth weight infants. The method used is based on the administration of deuterium and the collection of samples of saliva from the mother and the baby during the following 14 days. The FTIR is used to determine the amount of milk consumed by the baby and the maternal body composition. The zinc status in the maternal blood and milk is analysed using the ICP-SM. Results: The use, for the first time in Morocco, of isotopic techniques based on deuterium enrichment of saliva reveals a regression of exclusive breastfeeding in the country. In fact, the prevalence of babies exclusively breastfed is 33,3% for the first month, 26,7% at 3 months and only 12,5% at 6 months. As for the maternal milk intake, the amount of milk consumed during the 1st and 3rd months of life by the babies exclusively breastfed (respectively 690,3 ± 163,1 g/d and 891,8 ± 206,8 g/d) is significantly high compared to babies not exclusively breastfed (respectively 466,2 ± 189,1 g/d and 442,0 ± 117,5 g/d). The amount of milk consumed by the babies exclusively breastfed covers their energy requirements for the first 6 months. However, the body composition shows that babies born to mothers with percentage of body fat > 27% present a superior daily milk intake compared to babies born to mothers with percentage of body fat < 27%. The zinc content of maternal milk decreases between the first and sixth month of life. It is slightly lower in the milk of women paired to low birth weight babies. As for zinc content of maternal blood, results show low levels in the two study groups. Discussion: This study, the first one to be conducted in North of Africa, gives a better idea about the amount of milk consumed by babies less than 6

  8. Radiotracer technique to quantify change in filtration velocity as a measure of dilution effect by artificial recharge in an arsenic infested aquifer at Ashoknagar, Habra - II block, 24 Paragana district, West Bengal

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2004-01-01

    Radioisotopes are frequently employed as tracers for various applications in industry, agricultural, medicine and hydrology. In hydrology, radiotracers are commonly applied to investigate several hydrological parameters of aquifers such as hydraulic conductivity, groundwater velocity and direction of flow etc. They impart valuable insight into the understanding of the hydrological systems. Application of radioisotopes in determination of groundwater flow velocity is now a well established technique. In this paper, groundwater filtration velocity was determined in an arsenic infested alluvium aquifer at Ashoknagar, Habra, West Bengal for determining the dilution effect due to arsenic free water. In some parts of West Bengal, generally shallow aquifers up to 80 m deep are contaminated due to geogenic arsenic. Researchers have different views about origin and mobility of arsenic in the groundwaters of West Bengal. For the removal of Arsenic from the groundwater various methods have been suggested and implemented such as ion-exchange, co-precipitation, adsorption, membrane separation and dilution etc. Dilution of the Arsenic concentration by artificial recharge of arsenic free water from the constructed pits in the contaminated aquifer is one such simple method. Efficacy of this method was studied by measuring filtration velocity in the contaminated aquifer at the Ashoknagar, Habra - II Block, North 24 Paragana district, West Bengal. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater. Point dilution technique in a single well was applied. Filtration velocity provided relevant information about the arsenic dilution in the groundwater by the artificial recharge and its value will be used as a model parameter. (author)

  9. Mechanistic model to predict colostrum intake based on deuterium oxide dilution technique data and impact of gestation and prefarrowing diets on piglet intake and sow yield of colostrum.

    Science.gov (United States)

    Theil, P K; Flummer, C; Hurley, W L; Kristensen, N B; Labouriau, R L; Sørensen, M T

    2014-12-01

    The aims of the present study were to quantify colostrum intake (CI) of piglets using the D2O dilution technique, to develop a mechanistic model to predict CI, to compare these data with CI predicted by a previous empirical predictive model developed for bottle-fed piglets, and to study how composition of diets fed to gestating sows affected piglet CI, sow colostrum yield (CY), and colostrum composition. In total, 240 piglets from 40 litters were enriched with D2O. The CI measured by D2O from birth until 24 h after the birth of first-born piglet was on average 443 g (SD 151). Based on measured CI, a mechanistic model to predict CI was developed using piglet characteristics (24-h weight gain [WG; g], BW at birth [BWB; kg], and duration of CI [D; min]: CI, g=-106+2.26 WG+200 BWB+0.111 D-1,414 WG/D+0.0182 WG/BWB (R2=0.944). This model was used to predict the CI for all colostrum suckling piglets within the 40 litters (n=500, mean=437 g, SD=153 g) and was compared with the CI predicted by a previous empirical predictive model (mean=305 g, SD=140 g). The previous empirical model underestimated the CI by 30% compared with that obtained by the new mechanistic model. The sows were fed 1 of 4 gestation diets (n=10 per diet) based on different fiber sources (low fiber [17%] or potato pulp, pectin residue, or sugarbeet pulp [32 to 40%]) from mating until d 108 of gestation. From d 108 of gestation until parturition, sows were fed 1 of 5 prefarrowing diets (n=8 per diet) varying in supplemented fat (3% animal fat, 8% coconut oil, 8% sunflower oil, 8% fish oil, or 4% fish oil+4% octanoic acid). Sows fed diets with pectin residue or sugarbeet pulp during gestation produced colostrum with lower protein, fat, DM, and energy concentrations and higher lactose concentrations, and their piglets had greater CI as compared with sows fed potato pulp or the low-fiber diet (Pcoconut oil decreased lactose and increased DM concentrations of colostrum compared with other prefarrowing diets (P

  10. Assessment of body fat in the pony: part II. Validation of the deuterium oxide dilution technique for the measurement of body fat.

    Science.gov (United States)

    Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc

    2011-09-01

    Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.

  11. Applications of 15N-isotopic dilution techniques to study the recovery of nitrogen fertilizer in the soil and plant uptake in wheat cropping system

    International Nuclear Information System (INIS)

    Rouanet, Juan Luis; Godoy, Alejandra; Montenegro, Adolfo; Mera, Mario; Uribe, Hamil; Pino, Ines; Parada, Ana Maria; Nario, Adriana

    1999-01-01

    Soil erosion is a major concern of the Chilean Ministry of Agriculture, which supports actions to develop new approaches in order to decrease the loss of this fragile natural resource and to promote sustainable production systems. This study, based on the management of biological, chemical and physical characteristics of the soil, was aimed to save nitrogen fertilizer. Nitrogen fertilization is the most costly production factor in wheat cropping systems on Ultisols, one of the most eroded soil types in southern Chile. A field experiment was undertaken on a Ultisol (''Buenos Aires'' Farm) at Imperial, IX Region, during 1997 and 1998, in order to assess the nitrogen and water use efficiency by a wheat crop (cv. Dalcahue-INIA) under alternative soil tillage systems. 15 N-isotopic dilution techniques allowed determining aspects of plant nutrition, nitrogen and water movement in the soil, processes not evaluated so far under these conditions. A strip-plot field layout with four replications was used , with soil tillage systems (traditional, burning/no-till, and no burning/no-till) as the main plots and crop successions (wheat-lupin-wheat and lupin-wheat-oat) as the subplots (30 m-2). In each subplot, a microplot (1m-2 ) was delimited. N fertilizer in the form of urea was added on subplots, except the microplot, at the rate of 150 kg N ha-1. 15N-labelled urea at c. 10 atom % excess, at the rate of 150 kg N ha-1, was added to the microplots. The fertilizer was split three times, 10% at planting, 45% at tillering and 45% jointing stage. No significant differences were found for wheat grain yield among tillage treatments. N fertilizer recovery by the wheat crop was 43%, and 56% on the nitrogen found in plants was derived from soil. No significant differences for these proportions were found among treatments. Although the wheat crop did not respond to tillage treatments in terms of 15N recovery, the physiological nitrogen use efficiency, or grain production per unit of

  12. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  13. Combination of pentafluorophenylhydrazine derivatization and isotope dilution LC-MS/MS techniques for the quantification of apurinic/apyrimidinic sites in cellular DNA.

    Science.gov (United States)

    Li, Jie; Leung, Elvis M K; Choi, Martin M F; Chan, Wan

    2013-05-01

    Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/10(9) nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.

  14. Classification of obesity by means of the body mass index and verification by measurement of the body composition using the tritium dilution technique

    International Nuclear Information System (INIS)

    Leonhardt, W.; Fischer, S.; Weck, M.; Hanefeld, M.

    1988-01-01

    65 female and 142 male patients have been classified according to their body mass index (BMI) into the categories underweight (BMI 20 or less), normal weight (BMI over 20 - 25), overweight (BMI over 25 - 30), obesity (BMI over 30 - 40), and morbid obesity (BMI over 40). Body composition was measured in all patients using the tritium dilution method. Total body fat was calculated from the total body water values. Relative fat values increased from 17.1% (women) and 14.5% (men) resp. in underweight to 46.2% (women) and 43.3% (men) in morbid obesity. In all classes of BMI men exhibited higher values of body weight, body height and body water and lower values of absolute and relative fat as compared to women. However, the relative fat and water values, relative to 1 in the normal weight class, were equal for both sexes. The results demonstrate that the BMI is very well suited for the classification of obesity. (author)

  15. Measurement of N2 fixation in Sesbania aculeata pers. and Sorghum bicolor L. grown in intercropping system, under saline conditions, using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Khalifa, K.; Janat, M.

    2001-09-01

    A field experiment was conducted under saline conditions (soil EC e 15, water EC w 8 dS/m/m) to evaluate the performance of sole crops and inter crops of Sesbania aculeata and Sorghum bicolor (1:1 row ratio) in terms of dry matter production, total N yield, soil N uptake and N 2 -fixation using 15 N isotope dilution method. Dry matter yield in sole crop of sesbania was significantly higher that that of sole sorghum; whereas, that of the inter cropping was significantly lower than sole sesbania, but was similar to that produced by sole sorghum. Total nitrogen yield in sole sesbania was four-fold than that accumulated in sole sorghum, whereas, that of mixed cropping was 2.6 fold compared to that of sole sorghum. The LER of total N yield was higher than 1 reflecting a greater advantage of inter cropping system in terms of land use efficiency. The proportion of N derived from N 2 fixation (%Ndfa) in the sesbania was increased from 63 to 79%, for sole and inter cropping system, respectively. There was no evidence of a significant transfer of N from the sesbania to the sorghum. Results on the relative growth of plants on saline soil compared with non-saline soil clearly demonstrated that sesbania was more salt tolerant than the sorghum. soil nitrogen uptake by plants, particularly in sorghum, was adversely affected by salinity. However, amounts of N 2 fixed by sole sesbania grown is saline soil was close or even higher than on non-saline soil. The use of inter cropping systems of legumes and non-legumes could be a promising agricultural approach to reutilize wasted lands, after a careful selection of appropriate tolerant genotypes to prevailing saline conditions. (author)

  16. Measurement of N2 fixation in Sesbania aculeata and Sorghum bicolor L. grown in intercropping system using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Kurdali, F.; Khalifa, K.; Janat, M.

    2001-09-01

    A field experiment on Sesbania aculeata and Sorghum bicolor grown in mono cropping and in inter cropping systems was conducted under non-saline conditions (soil EC e 0.16, water EC w 1dS/m) to evaluate dry matter production, total N yield, soil N uptake and N 2 -fixation using 15 N isotope dilution method. Three different row ratios of sesbania (ses) and sorghum (sor) were subjected in the inter cropping system (2ses: 1sot; 1ses: 1sor and 1ses: 2sor row ratio). Dry matter yield of sole sorghum was higher than that of sole sesbania, and it was similar to that produced by the inter cropping treatments. However, total N yield of sole sorghum was significantly the lowest, with no differences being obtained between sole sesbania and inter cropping treatments. The LERs of total N yield were, in all cases, higher than 1, reflecting a greater advantage of inter cropping system in terms of land use efficiency. Percentages of N 2 fixation in the inter cropped sesbania were considerably enhanced compared with the pure stand of sesbania. This was mainly attributed to the depletion of soil N resulting from the greater apparent competitiveness of sorghum for soil N, and consequently, a greater dependence of sesbania on N 2 fixation. However, the degree of the intraspecific competition for soil N uptake was affected by the proportion of crops in the mixture, and it was considerably reduced in the 2ses: 1sor row ratio. This was demonstrated when an equal depletion of soil and fertilizer N uptake occurred for both crops. We excluded in all-inter cropping treatments the possibility of N transfer from sesbania to sorghum. Row inter cropping, with crops grown in alternation of two rows of sesbania with one row of sorghum, seemed to be the most adequate row ratio in terms of total N yield, LER, N 2 -fixation and soil N uptake balance of the component crops. (author)

  17. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The IAEA has fostered the more widespread use of a stable isotope technique to assess body composition in different population groups to address priority areas in public health nutrition in Member States. It has done this by supporting national and regional nutrition projects through its technical cooperation programme and coordinated research projects over many years. This publication was developed by an international group of experts to provide practical hands-on guidance in the use of this technique in settings where analysis of stable isotope ratios in biological samples is to be made by isotope ratio mass spectrometry. The publication is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical applications of state of the art methodologies to monitor changes in body composition can be found in IAEA Human Health Series No. 3, Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques

  18. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The IAEA has fostered the more widespread use of a stable isotope technique to assess body composition in different population groups to address priority areas in public health nutrition in Member States. It has done this by supporting national and regional nutrition projects through its technical cooperation programme and coordinated research projects over many years. This publication was developed by an international group of experts to provide practical hands-on guidance in the use of this technique in settings where analysis of stable isotope ratios in biological samples is to be made by isotope ratio mass spectrometry. The publication is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical applications of state of the art methodologies to monitor changes in body composition can be found in IAEA Human Health Series No. 3, Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques

  19. Sm isotope composition and Sm/Eu ratio determination in an irradiated 153Eu sample by ion exchange chromatography-quadrupole inductively coupled plasma mass spectrometry combined with double spike isotope dilution technique

    International Nuclear Information System (INIS)

    Bourgeois, M.; Isnard, H.; Gourgiotis, A.; Stadelmann, G.; Gautier, C.; Mialle, S.; Nonell, A.; Chartier, F.

    2011-01-01

    Within the framework of the research undertaken by the French Atomic Energy Commission on transmutation of long-lived radionuclides, targets of highly enriched actinides and fission products were irradiated in the fast neutron reactor Phenix. Precise and accurate measurements of the isotopic and elemental composition of the enriched elements are therefore required. In order to obtain the uncertainties of several per mil and to reduce handling time and exposure to analyst on radioactive material, the on-line coupling of ion exchange chromatography with quadrupole inductively coupled plasma mass spectrometry has been associated with the technique of the double spike isotope dilution. We present in this paper the results obtained on an irradiated sample of Europium oxide powder (enriched at 99.13% in 153 Eu). After irradiation of around 5 mg of Eu 2 O 3 powder the theoretical calculations predict the formation of several micrograms of gadolinium and samarium isotopes. In relation to the very high activity of the sample after irradiation and the very low quantity of Sm formed, the on-line ion exchange chromatography separation of Gd, Sm and Eu before Sm isotope ratio measurements has been developed for the quantification of the 152 Sm/ 153 Eu ratio. These on-line measurements were associated with the double spike isotope dilution technique after calibration of a 147 Sm/ 151 Eu spike solution. The external reproducibility of Sm isotopic ratios was determined to be around 0.5% (2 σ) resulting in a final uncertainty on the 152 Sm/ 153 Eu ratio of around 1% (2 σ). These on-line measurements present therefore a robust and high-throughput alternative to the thermal-ionisation mass spectrometry technique used so far in combination with off-line chromatographic separation, particularly in nuclear applications where characterisation of high activity sample solutions is required. (authors)

  20. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Saliva Samples by Fourier Transform Infrared Spectrometry (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    For many years, the IAEA has fostered the more widespread use of stable isotope techniques to assess body composition in different population groups to address priority areas in public health nutrition in Member States. The objective is to support national and regional nutrition projects through both the IAEA's technical cooperation programme and its coordinated research projects. In particular, during the last few years, the increased access to analyses of deuterium enrichment by Fourier transform infrared (FTIR) spectrometry has increased the application of this technique in Africa, Asia and Latin America. This publication was developed by an international group of experts to provide practical, hands-on guidance in the use of this technique in settings where the analysis of deuterium enrichment in saliva samples will be made by FTIR. It is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical application of state of the art methodologies to monitor changes in body composition can be found in an IAEA publication entitled Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques (IAEA Human Health Series No. 3)

  1. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Saliva Samples by Fourier Transform Infrared Spectrometry (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    For many years, the IAEA has fostered the more widespread use of stable isotope techniques to assess body composition in different population groups to address priority areas in public health nutrition in Member States. The objective is to support national and regional nutrition projects through both the IAEA's technical cooperation programme and its coordinated research projects. In particular, during the last few years, the increased access to analyses of deuterium enrichment by Fourier transform infrared (FTIR) spectrometry has increased the application of this technique in Africa, Asia and Latin America. This publication was developed by an international group of experts to provide practical, hands-on guidance in the use of this technique in settings where the analysis of deuterium enrichment in saliva samples will be made by FTIR. It is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical application of state of the art methodologies to monitor changes in body composition can be found in an IAEA publication entitled Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques (IAEA Human Health Series No. 3)

  2. Measurement of N{sub 2} fixation in Sesbania aculeata and Sorghum bicolor L. grown in intercropping system using {sup 15}N isotopic dilution technique

    Energy Technology Data Exchange (ETDEWEB)

    Kurdali, F; Khalifa, K; Janat, M [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Agriculture

    2001-09-01

    A field experiment on Sesbania aculeata and Sorghum bicolor grown in mono cropping and in inter cropping systems was conducted under non-saline conditions (soil EC{sub e} 0.16, water EC{sub w}1dS/m) to evaluate dry matter production, total N yield, soil N uptake and N{sub 2}-fixation using {sup 15}N isotope dilution method. Three different row ratios of sesbania (ses) and sorghum (sor) were subjected in the inter cropping system (2ses: 1sot; 1ses: 1sor and 1ses: 2sor row ratio). Dry matter yield of sole sorghum was higher than that of sole sesbania, and it was similar to that produced by the inter cropping treatments. However, total N yield of sole sorghum was significantly the lowest, with no differences being obtained between sole sesbania and inter cropping treatments. The LERs of total N yield were, in all cases, higher than 1, reflecting a greater advantage of inter cropping system in terms of land use efficiency. Percentages of N{sub 2} fixation in the inter cropped sesbania were considerably enhanced compared with the pure stand of sesbania. This was mainly attributed to the depletion of soil N resulting from the greater apparent competitiveness of sorghum for soil N, and consequently, a greater dependence of sesbania on N{sub 2} fixation. However, the degree of the intraspecific competition for soil N uptake was affected by the proportion of crops in the mixture, and it was considerably reduced in the 2ses: 1sor row ratio. This was demonstrated when an equal depletion of soil and fertilizer N uptake occurred for both crops. We excluded in all-inter cropping treatments the possibility of N transfer from sesbania to sorghum. Row inter cropping, with crops grown in alternation of two rows of sesbania with one row of sorghum, seemed to be the most adequate row ratio in terms of total N yield, LER, N{sub 2}-fixation and soil N uptake balance of the component crops. (author)

  3. Hybridizing pines with diluted pollen

    Science.gov (United States)

    Robert Z. Callaham

    1967-01-01

    Diluted pollens would have many uses by the tree breeder. Dilutions would be particularly advantageous in making many controlled pollinations with a limited amount of pollen. They also would be useful in artificial mass pollinations of orchards or single trees. Diluted pollens might help overcome troublesome genetic barriers to crossing. Feasibility o,f using diluted...

  4. Functional characterisation of semen in honeybee queen (A.m.ligustica S. spermatheca and efficiency of the diluted semen technique in instrumental insemination

    Directory of Open Access Journals (Sweden)

    Andrea Galli

    2010-01-01

    Full Text Available Differences over time in the quality of semen present in the honey bee (Apis mellifera ligustica queen spermatheca werestudied. An increase in the non-vital spermatozoa was shown to be evident (P>0.05 between the 12th and 24th month.The study of semen viability demonstrated that the passage of the semen to the spermatheca is due to sperm motility.In the queen inseminated with non-viable spermatozoa, no semen was detected in the spermatheca. Queens inseminatedtwice with a Hyes solution/semen mixture (1:1 stored as many spermatozoa in their spermatheca as those inseminatedonce with the classic technique. Queen replacement, oviposition and other functional characteristics were similarto those observed in the classic insemination procedure.

  5. Helium dilution refrigerator

    International Nuclear Information System (INIS)

    1973-01-01

    A new system of continuous heat exchange for a helium dilution refrigerator is proposed. The 3 He effluent tube is concurrent with the affluent mixed helium tube in a vertical downward direction. Heat exchange efficiency is enhanced by placing in series a number of elements with an enlarged surface area

  6. Gluconeogenesis from labeled carbon: estimating isotope dilution

    International Nuclear Information System (INIS)

    Kelleher, J.K.

    1986-01-01

    To estimate the rate of gluconeogenesis from steady-state incorporation of labeled 3-carbon precursors into glucose, isotope dilution must be considered so that the rate of labeling of glucose can be quantitatively converted to the rate of gluconeogenesis. An expression for the value of this isotope dilution can be derived using mathematical techniques and a model of the tricarboxylic acid (TCA) cycle. The present investigation employs a more complex model than that used in previous studies. This model includes the following pathways that may affect the correction for isotope dilution: 1) flux of 3-carbon precursor to the oxaloacetate pool via acetyl-CoA and the TCA cycle; 2) flux of 4- or 5-carbon compounds into the TCA cycle; 3) reversible flux between oxaloacetate (OAA) and pyruvate and between OAA and fumarate; 4) incomplete equilibrium between OAA pools; and 5) isotope dilution of 3-carbon tracers between the experimentally measured pool and the precursor for the TCA-cycle OAA pool. Experimental tests are outlined which investigators can use to determine whether these pathways are significant in a specific steady-state system. The study indicated that flux through these five pathways can significantly affect the correction for isotope dilution. To correct for the effects of these pathways an alternative method for calculating isotope dilution is proposed using citrate to relate the specific activities of acetyl-CoA and OAA

  7. Defects in dilute nitrides

    International Nuclear Information System (INIS)

    Chen, W.M.; Buyanova, I.A.; Tu, C.W.; Yonezu, H.

    2005-01-01

    We provide a brief review our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in dilute nitrides, i.e. Ga(In)NAs and Ga(Al,In)NP. Defect complexes involving intrinsic defects such as As Ga antisites and Ga i self interstitials were positively identified.Effects of growth conditions, chemical compositions and post-growth treatments on formation of the defects are closely examined. These grown-in defects are shown to play an important role in non-radiative carrier recombination and thus in degrading optical quality of the alloys, harmful to performance of potential optoelectronic and photonic devices based on these dilute nitrides. (author)

  8. New experiences in borehole dilution techniques

    International Nuclear Information System (INIS)

    Umesh Chandra

    1977-01-01

    A study of filtration rate and direction of groundwater flow was made at various depths in borehole using bromine-82 as groundwater tracer. The filtration rates were found to vary along the depth of borehole. Vertical flow in the borehole was observed in an alluvial aquifer even after sealing the borehole by rubber packers. The filtration rates, obtained without the packer at various depths, were much less than those obtained with packer. Microscopic hydrological information was obtained around the borehole which was useful in planning a drainage system in the area. A depth was located in the borehole where vertical flow was in opposite directions. At another depth a zone of horizontal flow was observed where vertical flow was in opposite directions. The improved instrumentation used rendered the field work extremely easy quick and readily reproducible. (author)

  9. Effect of sheep manure and phosphorus application on growth, yield, and N2 - fixation of inoculated soybean (Glycine max (L.) Merr) grown on Syrian arid soils using the 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Khalifa, Kh.; Al-Ain, F.; Al-Shamma'a, M.

    2003-10-01

    A field experiment was carried out in Syrian arid soils at Deir Al-Hajar research station to study the effect of different rates of sheep manure (0, 20, and 40 ton/ha) and levels of P- fertilizer (0, 40 and 80 kg P 2 O 5 /ha) on dry matter production and N 2 fixation by Soybean [(Glycine max) (SB171 variety)], of which seeds were inoculated by Bradyrhizobium japonicum-FA3 bacterial. Sorghum bicolor L. was employed as a reference crop ti evaluate N 2 -fixation using the 15 N-isotope dilution technique. In general, results indicated that, a positive effects were found to adding Sheep Manure or P-fertilizer on D.M production in different plants parts of soybean (shoots, roots, pods). This effect was more pronounced when adding sheep manure and phosphorus together especially under the optimum M40P80 treatment. Quantity of N-fixed by Soybean responds positively to sole application of Sheep Manure or P-fertilizer. Moreover, the optimum combined treatment showed significant increases in the quantity of nitrogen derived from the atmosphere (Qndfa), which were (3.29, 25.54, 53.49 kg N/ha) in roots, shoots, and pods respectively. P-fertilization resulted in a significant increase in the percentage of nitrogen use efficiency (NUE) with increasing phosphorus levels added to Sorghum plants; However, an adverse effect was noticed for the NUE when using sheep manure solely or in combination with P-fertilizer. (author)

  10. The use of 32P dilution techniques to evaluate the effect of mycorrhizal inoculation on plant uptake of P from products of fermentation mixtures including agrowastes, Aspergillus niger and rock phosphate

    International Nuclear Information System (INIS)

    Vassilev, N.; Vassileva, M.; Azcon, R.; Barea, J.-M.

    2002-01-01

    Some microorganisms, such as filamentous fungi, are capable of solubilizing rock phosphate products, which are a less costly alternative to conventional P fertilizers used so far in agriculture. However, metabolizable C compounds must be supplied to the microbes to solubilize rock phosphate (RP). On another hand, huge quantities of organic materials are produced by cultivated plants every year and their residues became agrowastes, which may often pose significant environmental problems. An attractive approach to solubilize RP would therefore, be the application of microorganisms possessing a high acid-producing activity in fermentation processes based on agrowastes. In this context, Aspergillus niger was successfully cultivated on sugar beet (SB) waste material supplemented with 3.0 g/l RP acidifying the medium by releasing citric acid and thus decreasing the pH to 3.0-3.5. At the end of the solid-state fermentation process, the product contained mineralized (69%) organic matter, RP solubilized to 224 μg/ml and fungal mycelium. A series of microcosms greenhouse experiments were then carried out aimed at evaluating the effectiveness of such product, added at a rate of 5% (v/v), to a neutral, calcareous, P-deficient soil. Clover (Trifolium repens) inoculated or not with an arbuscular mycorrhizal fungus, was the test plant. It was shown that the product improved plant growth and P acquisition. Mycorrhizal inoculation further enhanced the effectiveness of the fermentation product. The use of the isotopic 32 P dilution technique showed a lowering of the specific activity of the treated plants, thus indicating that plants benefited from P solublilized from RP by the microbial treatments applied in this experiment. The reported biotechnological approach offers a potential application for sustainability purposes. (author)

  11. Gas-surface interactions using accommodation coefficients for a dilute and a dense gas in a micro/nano-channel : heat flux predictions using combined molecular dynamics and Monte Carlo techniques

    NARCIS (Netherlands)

    Gaastra - Nedea, S.V.; Steenhoven, van A.A.; Markvoort, A.J.; Spijker, P.; Giordano, D.

    2014-01-01

    The influence of gas-surface interactions of a dilute gas confined between two parallel walls on the heat flux predictions is investigated using a combined Monte Carlo (MC) and molecular dynamics (MD) approach. The accommodation coefficients are computed from the temperature of incident and

  12. EXAFS of dilute systems: fluorescence detection

    International Nuclear Information System (INIS)

    Hastings, J.B.

    1979-01-01

    Since the first observations of the variation of the absorption coefficient for x-rays above the energy thresholds in the thirties until the early seventies, measurements and analysis of these variations were merely intended for the understanding of the underlying physics. Recently, with the understanding of the information available about the local atomic structure in the neighborhood of the absorbing species and the availability of high intensity synchrotron radiation sources, EXAFS has become a powerful structural tool. In these discussions, the details of the measurements for very dilute species are presented. It is shown that for the more dilute systems the measurement of the emission rather than the direct absorption is a more favorable technique

  13. Phase diagrams of diluted transverse Ising nanowire

    Energy Technology Data Exchange (ETDEWEB)

    Bouhou, S.; Essaoudi, I. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Ainane, A., E-mail: ainane@pks.mpg.de [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Saber, M. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Ahuja, R. [Condensed Matter Theory Group, Department of Physics and Astronomy, Uppsala University, 75120 Uppsala (Sweden); Dujardin, F. [Laboratoire de Chimie et Physique des Milieux Complexes (LCPMC), Institut de Chimie, Physique et Matériaux (ICPM), 1 Bd. Arago, 57070 Metz (France)

    2013-06-15

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J{sub cs} exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given.

  14. Phase diagrams of diluted transverse Ising nanowire

    International Nuclear Information System (INIS)

    Bouhou, S.; Essaoudi, I.; Ainane, A.; Saber, M.; Ahuja, R.; Dujardin, F.

    2013-01-01

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J cs exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given

  15. Extremity exams optimization for computed radiography; Otimizacao de exames de extremidade para radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, Ana Luiza M.; Alves, Allan Felipe F.; Velo, Alexandre F.; Miranda, Jose Ricardo A., E-mail: analuiza@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Pina, Diana R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2013-08-15

    The computed radiography (CR) has become the most used device for image acquisition, since its introduction in the 80s. The detection and early diagnosis, obtained through CR examinations, are important for the successful treatment of diseases of the hand. However, the norms used for optimization of these images are based on international protocols. Therefore, it is necessary to determine letters of radiographic techniques for CR system, which provides a safe medical diagnosis, with doses as low as reasonably achievable. The objective of this work is to develop an extremity homogeneous phantom to be used in the calibration process of radiographic techniques. In the construction process of the simulator, it has been developed a tissues' algorithm quantifier using Matlab®. In this process the average thickness was quantified from bone and soft tissues in the region of the hand of an anthropomorphic simulator as well as the simulators' material thickness corresponding (aluminum and Lucite) using technique of mask application and removal Gaussian histogram corresponding to tissues of interest. The homogeneous phantom was used to calibrate the x-ray beam. The techniques were implemented in a calibrated hand anthropomorphic phantom. The images were evaluated by specialists in radiology by the method of VGA. Skin entrance surface doses were estimated (SED) corresponding to each technique obtained with their respective tube charge. The thicknesses of simulators materials that constitute the homogeneous phantom determined in this study were 19.01 mm of acrylic and 0.81 mm of aluminum. A better picture quality with doses as low as reasonably achievable decreased dose and tube charge around 53.35% and 37.78% respectively, compared normally used by radiology diagnostic routine clinical of HCFMB-UNESP. (author)

  16. Contrast optimization in multiphase arterial spin labeling; Otimizacao do contraste em ASL multi-fase

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Fernando F.; Paschoal, Andre M., E-mail: paiva@ifsc.usp.br [Universidade de Sao Paulo (CIERMag/USP), Sao Carlos, SP (Brazil). Instituto de Fisica; Foerster, Bernd U. [Philips Medical Systems LatAm, Sao Paulo, SP (Brazil); Tovar-Moll, Fernanda; Moll, Jorge [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Multiphase ASL is an effective way to overcome the regional variation of the transit time that difficult the estimation of perfusion values. However, with conventional multiple phases ASL techniques, the ASL contrast at later phases is impaired due to repeated application of excitation pulses and longitudinal relaxation making it difficult to evaluate the tissue perfusion in regions where the transit time is longer. In the present study, we show an improvement of the acquisition scheme by exploring a modulation on the flip angle of the MR acquisition to keep the ASL contrast constant over multiple phases. (author)

  17. Procedures for accurately diluting and dispensing radioactive solutions

    International Nuclear Information System (INIS)

    1975-01-01

    The technique currently used by various laboratories participating in international comparisons of radioactivity measurements are surveyed and recommendations for good laboratory practice established. Thus one describes, for instance, the preparation of solutions, dilution techniques, the use of 'pycnometers', weighing procedures (including buyoancy correction), etc. It should be possible to keep random and systematic uncertainties below 0.1% of the final result

  18. Dilute chemical decontamination program review

    International Nuclear Information System (INIS)

    Anstine, L.D.; Blomgren, J.C.; Pettit, P.J.

    1980-01-01

    The objective of the Dilute Chemical Decontamination Program is to develop and evaluate a process which utilizes reagents in dilute concentrations for the decontamination of BWR primary systems and for the maintenance of dose rates on the out-of-core surfaces at acceptable levels. A discussion is presented of the process concept, solvent development, advantages and disadvantages of reagent systems, and VNC loop tests. Based on the work completed to date it is concluded that (1) rapid decontamination of BWRs using dilute reagents is feasible; (2) reasonable reagent conditions for rapid chemical decontamination are: 0.01M oxalic acid + 0.005M citric acid, pH3.0, 90/degree/C, 0.5 to 1.0 ppm dissolved oxygen; (3) control of dissolved oxygen concentration is important, since high levels suppress the rate of decontamination and low levels allow precipitation of ferrous oxalate. 4 refs

  19. Delayed coking unit preheat train optimization; Otimizacao do preaquecimento das Unidades de Coque

    Energy Technology Data Exchange (ETDEWEB)

    Marins, Edson R; Geraldelli, Washington O; Barros, Francisco C [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    The oil industry has been investing in research and development of new techniques and process improvements with the objective to increase the residual fraction profitability and to fulfill the market demands. The adequacy of the refining scheme has led to the development of bottom of the barrel processes that has the objective to convert heavy fractions into products of higher aggregate value. In this context, the process of Delayed Coking presents a great importance in the production of distillates in the diesel range as well as the processing of heavy residues, mostly in the markets where the fuel oil consumption is being reduced. With the approach to help PETROBRAS decide which route to follow during new designs of Delayed Coking units, this work presents a comparative study of the preheat train performance among the energy recovery to preheat the feed, in contrast with preheating the feed and generating steam, simultaneously. In this study the Pinch Technology methodology was used as a procedure for heat integration with the objective of getting the maximum energy recovery from the process, finding the best trade-off between operational cost and investment cost. The alternative of steam generation aims to provide an appropriate flexibility in Delayed Coking units design and operation. (author)

  20. Primary system boron dilution analysis

    International Nuclear Information System (INIS)

    Crump, R.J.; Naretto, C.J.; Borgen, R.A.; Rockhold, H.C.

    1978-01-01

    The results are presented for an analysis conducted to determine the potential paths through which nonborated water or water with insufficient boron concentration might enter the LOFT primary coolant piping system or reactor vessel to cause dilution of the borated primary coolant water. No attempt was made in the course of this analysis to identify possible design modifications nor to suggest changes in administrative procedures or controls

  1. Cryogen-free dilution refrigerators

    International Nuclear Information System (INIS)

    Uhlig, K

    2012-01-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4 He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4 He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  2. Cryogen-free dilution refrigerators

    Science.gov (United States)

    Uhlig, K.

    2012-12-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  3. Plutonium determination by isotope dilution

    International Nuclear Information System (INIS)

    Lucas, M.

    1980-01-01

    The principle is to add to a known amount of the analysed solution a known amount of a spike solution consisting of plutonium 242. The isotopic composition of the resulting mixture is then determined by surface ionization mass spectrometry, and the plutonium concentration in the solution is deduced, from this measurement. For irradiated fuels neutronic studies or for fissile materials balance measurements, requiring the knowledge of the ratio U/Pu or of concentration both uranium and plutonium, it is better to use the double spike isotope dilution method, with a spike solution of known 233 U- 242 Pu ratio. Using this method, the ratio of uranium to plutonium concentration in the irradiated fuel solution can be determined without any accurate measurement of the mixed amounts of sample and spike solutions. For fissile material balance measurements, the uranium concentration is determined by using single isotope dilution, and the plutonium concentration is deduced from the ratio Pu/U and U concentration. The main advantages of isotope dilution are its selectivity, accuracy and very high sensitivity. The recent improvements made to surface ionization mass spectrometers have considerably increased the precision of the measurements; a relative precision of about 0.2% to 0.3% is obtained currently, but it could be reduced to 0.1%, in the future, with a careful control of the experimental procedures. The detection limite is around 0.1 ppb [fr

  4. Neutron scattering study of dilute supercritical solutions

    International Nuclear Information System (INIS)

    Cochran, H.D.; Wignall, G.D.; Shah, V.M.; Londono, J.D.; Bienkowski, P.R.

    1994-01-01

    Dilute solutions in supercritical solvents exhibit interesting microstructures that are related to their dramatic macroscopic behavior. In typical attractive solutions, solutes are believed to be surrounded by clusters of solvent molecules, and solute molecules are believed to congregate in the vicinity of one another. Repulsive solutions, on the other hand, exhibit a local region of reduced solvent density around the solute with solute-solute congregation. Such microstructures influence solubility, partial molar volume, reaction kinetics, and many other properties. We have undertaken to observe these interesting microstructures directly by neutron scattering experiments on dilute noble gas systems including Ar. The three partial structure factors for such systems and the corresponding pair correlation functions can be determined by using the isotope substitution technique. The systems studied are uniquely suited for our objectives because of the large coherent neutron scattering length of the isotope 36 Ar and because of the accurate potential energy functions that are available for use in molecular simulations and theoretical calculations to be compared with the scattering results. We will describe our experiment, the unique apparatus we have built for it, and the neutron scattering results from our initial allocations of beam time. We will also describe planned scattering experiments to follow those with noble gases, including study of long-chain molecules in supercritical solvents. Such studies will involve hydrocarbon mixtures with and without deuteration to provide contrast

  5. Measurement of N{sub 2} fixation in Sesbania aculeata pers. and Sorghum bicolor L. grown in intercropping system, under saline conditions, using {sup 15}N isotopic dilution technique

    Energy Technology Data Exchange (ETDEWEB)

    Kurdali, F; Khalifa, K; Janat, M [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Agriculture

    2001-09-01

    A field experiment was conducted under saline conditions (soil EC{sub e} 15, water EC{sub w} 8 dS/m/m) to evaluate the performance of sole crops and inter crops of Sesbania aculeata and Sorghum bicolor (1:1 row ratio) in terms of dry matter production, total N yield, soil N uptake and N{sub 2}-fixation using {sup 15}N isotope dilution method. Dry matter yield in sole crop of sesbania was significantly higher that that of sole sorghum; whereas, that of the inter cropping was significantly lower than sole sesbania, but was similar to that produced by sole sorghum. Total nitrogen yield in sole sesbania was four-fold than that accumulated in sole sorghum, whereas, that of mixed cropping was 2.6 fold compared to that of sole sorghum. The LER of total N yield was higher than 1 reflecting a greater advantage of inter cropping system in terms of land use efficiency. The proportion of N derived from N{sub 2} fixation (%Ndfa) in the sesbania was increased from 63 to 79%, for sole and inter cropping system, respectively. There was no evidence of a significant transfer of N from the sesbania to the sorghum. Results on the relative growth of plants on saline soil compared with non-saline soil clearly demonstrated that sesbania was more salt tolerant than the sorghum. soil nitrogen uptake by plants, particularly in sorghum, was adversely affected by salinity. However, amounts of N{sub 2} fixed by sole sesbania grown is saline soil was close or even higher than on non-saline soil. The use of inter cropping systems of legumes and non-legumes could be a promising agricultural approach to reutilize wasted lands, after a careful selection of appropriate tolerant genotypes to prevailing saline conditions. (author)

  6. The application of isotopic (32P and 15N) dilution techniques to evaluate the interactive effect of phosphate-solubilizing rhizobacteria, mycorrhizal fungi and Rhizobium to improve the agronomic efficiency of rock phosphate for legume crops

    International Nuclear Information System (INIS)

    Barea, J.M.; Toro, M.; Azcon, R.; Orozco, M.O.; Campos, E.; Azcon, R.

    2002-01-01

    A pot experiment was designed to evaluate the interactive effects of multifunctional microbial inoculation treatments and rock phosphate (RP) application on N and P uptake by alfalfa through the use of 15 N and 32 P isotopic dilution approaches. The microbial inocula consisted of a wild type (WT) Rhizobium meliloti strain, the arbuscular mycorrhizal (AM) fungus Glomus mosseae (Nicol. and Gerd.) Gerd. and Trappe, and a phosphate solubilizing rhizobacterium (Enterobacter sp.). Inoculated microorganisms were established in the root tissues and/or in the rhizosphere soil of alfalfa plants (Medicago sativa L.). Improvements in N and P accumulation in alfalfa corroborate beneficial effects of Rhizobium and AM interactions. Inoculation with selected rhizobacteria improved the AM effect on N or P accumulation in both the RP-added soil and in the non RP-amended controls. Measurements of the 15 N/ 14 N ratio in plant shoots indicate an enhancement of the N 2 fixation rates in Rhizobium-inoculated AM-plants, over that achieved by Rhizobium in non-mycorrhizal plants. Whether or not RP was added, AM-inoculated plants showed a lower specific activity ( 32 P/ 31 P) than did their comparable non-mycorrhizal controls, suggesting that the plant was using otherwise unavailable P sources. The phosphate-solubilizing, AM-associated, microbiota could in fact release phosphate ions, either from the added RP or from the indigenous 'less-available' soil phosphate. A low Ca concentrations in the test soil may have benefited P solubilization. Under field conditions, the inoculation with AM fungi significantly increased plant biomass and N and P accumulation in plant tissues. Phosphate-solubilizing rhizobacteria improved mycorrhizal responses in soil dually receiving RP and organic matter amendments. Organic matter addition favoured RP solubilization. This, together with a tailored microbial inoculation, increased the agronomic efficiency of RP in the test soil that was Ca deficient at neutral

  7. The application of isotopic ({sup 32}P and {sup 15}N) dilution techniques to evaluate the interactive effect of phosphate-solubilizing rhizobacteria, mycorrhizal fungi and Rhizobium to improve the agronomic efficiency of rock phosphate for legume crops

    Energy Technology Data Exchange (ETDEWEB)

    Barea, J.M. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain)]. E-mail: jmbarea@eez.csic.es; Toro, M.; Azcon, R. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain); Orozco, M.O. [Instituto de Sistematica y Ecologia, Academia Cubana de Ciencias, Habana (Cuba); Campos, E. [Departamento de Ciencias de la Tierra y Quimica Ambiental Estacion Experimental del Zaidin (CSIC), Granada (Spain); Azcon, R. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain)

    2002-05-15

    A pot experiment was designed to evaluate the interactive effects of multifunctional microbial inoculation treatments and rock phosphate (RP) application on N and P uptake by alfalfa through the use of {sup 15}N and {sup 32}P isotopic dilution approaches. The microbial inocula consisted of a wild type (WT) Rhizobium meliloti strain, the arbuscular mycorrhizal (AM) fungus Glomus mosseae (Nicol. and Gerd.) Gerd. and Trappe, and a phosphate solubilizing rhizobacterium (Enterobacter sp.). Inoculated microorganisms were established in the root tissues and/or in the rhizosphere soil of alfalfa plants (Medicago sativa L.). Improvements in N and P accumulation in alfalfa corroborate beneficial effects of Rhizobium and AM interactions. Inoculation with selected rhizobacteria improved the AM effect on N or P accumulation in both the RP-added soil and in the non RP-amended controls. Measurements of the {sup 15}N/{sup 14}N ratio in plant shoots indicate an enhancement of the N{sub 2} fixation rates in Rhizobium-inoculated AM-plants, over that achieved by Rhizobium in non-mycorrhizal plants. Whether or not RP was added, AM-inoculated plants showed a lower specific activity ({sup 32}P/{sup 31}P) than did their comparable non-mycorrhizal controls, suggesting that the plant was using otherwise unavailable P sources. The phosphate-solubilizing, AM-associated, microbiota could in fact release phosphate ions, either from the added RP or from the indigenous 'less-available' soil phosphate. A low Ca concentrations in the test soil may have benefited P solubilization. Under field conditions, the inoculation with AM fungi significantly increased plant biomass and N and P accumulation in plant tissues. Phosphate-solubilizing rhizobacteria improved mycorrhizal responses in soil dually receiving RP and organic matter amendments. Organic matter addition favoured RP solubilization. This, together with a tailored microbial inoculation, increased the agronomic efficiency of RP in the

  8. Mechanisms of urine concentration and dilution (1961)

    International Nuclear Information System (INIS)

    Morel, F.; Guinnebault, M.

    1961-01-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [fr

  9. Guideline on Isotope Dilution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Amy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-19

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. This method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.

  10. A miniaturized plastic dilution refrigerator

    International Nuclear Information System (INIS)

    Bindilatti, V.; Oliveira, N.F.Jr.; Martin, R.V.; Frossati, G.

    1996-01-01

    We have built and tested a miniaturized dilution refrigerator, completely contained (still, heat exchanger and mixing chamber) inside a plastic (PVC) tube of 10 mm diameter and 170 mm length. With a 25 cm 2 CuNi heat exchanger, it reached temperatures below 50 mK, for circulation rates below 70 μmol/s. The cooling power at 100 mK and 63 μmol/s was 45 μW. The experimental space could accommodate samples up to 6 mm in diameter. (author)

  11. Measurement of N2 fixation in Sesbania aculeata pers. and Sorghum bicolor L. grown in intercropping system, using sup 1 sup 5 N isotopic dilution technique. 1: Field evaluation under non-saline conditions

    International Nuclear Information System (INIS)

    Kurdali, F.; Khalifa, K.; Janat, M.

    2002-01-01

    A field experiment on Sesbania aculeata and Sorghum bicolor grown in mono cropping and in inter cropping systems was conducted under non-saline conditions (soil EC sub e 0.16, water EC sub w 1 ds/m/m) to evaluate dry matter production, total N yield, soil N uptake and N sub 2 -fixation using sup 1 sup 5 N isotope dilution method. Three different row ratios of sesbania (ses) and sorghum (sor) were subjected in the inter cropping system (2 ses: 1 sor; 1 ses: 1 sor and 1 ses: 2 sor row ratio). Dry matter yield of sole sorghum was higher than that of sole sesbania, and it was similar to that produced by the inter cropping treatments. However, total N yield of sole sorghum was significantly the lowest, with no differences being obtained between sole sesbania and inter cropping treatments. The LERs of total N yield were, in all cases, higher than 1, reflecting a greater advantage of inter cropping system in terms of land use efficiency. Percentages of N sub 2 fixation in the inter cropped sesbania were considerably enhanced compared with the pure stand of sesbania. This was mainly attributed to the depletion of soil N resulting from the greater apparent competitiveness of sorghum for soil N, and consequently, a greater dependence of sesbania on N sub 2 fixation. However, the degree of the intraspecific competition for soil N uptake was affected by the proportion of crops in the mixture, and it was considerably reduced in the 2 ses: 1 sor row ratio. This was demonstrated when an equal depletion of soil and fertilizer N uptake occurred for both crops. We excluded in all-inter cropping treatments the possibility of N transfer from sesbania to sorghum. Row inter cropping, with crops grown in alternation of two rows of sesbania with one row of sorghum, seemed to be the most adequate row ratio in terms of total N yield, LER, N sub 2 -fixation and soil N uptake balance of the component crops. (author)

  12. Buffer erosion in dilute groundwater

    International Nuclear Information System (INIS)

    Schatz, T.; Kanerva, N.; Martikainen, J.; Sane, P.; Olin, M.; Seppaelae, A.; Koskinen, K.

    2013-08-01

    One scenario of interest for repository safety assessment involves the loss of bentonite buffer material in contact with dilute groundwater flowing through a transmissive fracture interface. In order to examine the extrusion/erosion behavior of bentonite buffer material under such circumstances, a series of experiments were performed in a flow-through, 1 mm aperture, artificial fracture system. These experiments covered a range of solution chemistry (salt concentration and composition), material composition (sodium montmorillonite and admixtures with calcium montmorillonite), and flow velocity conditions. No erosion was observed for sodium montmorillonite against solution compositions from 0.5 g/L to 10 g/L NaCl. No erosion was observed for 50/50 calcium/sodium montmorillonite against 0.5 g/L NaCl. Erosion was observed for both sodium montmorillonite and 50/50 calcium/sodium montmorillonite against solution compositions ≤ 0.25 g/L NaCl. The calculated erosion rates for the tests with the highest levels of measured erosion, i.e., the tests run under the most dilute conditions (ionic strength (IS) < ∼1 mM), were well-correlated to flow velocity, whereas the calculated erosion rates for the tests with lower levels of measured erosion, i.e., the tests run under somewhat less dilute conditions (∼1 mM < IS < ∼4 mM), were not similarly correlated indicating that material and solution composition can significantly affect erosion rates. In every experiment, both erosive and non-erosive, emplaced buffer material extruded into the fracture and was observed to be impermeable to water flowing in the fracture effectively forming an extended diffusive barrier around the intersecting fracture/buffer interface. Additionally, a model which was developed previously to predict the rate of erosion of bentonite buffer material in low ionic strength water in rock fracture environments was applied to three different cases: sodium montmorillonite expansion in a vertical tube, a

  13. Desynchronization in diluted neural networks

    International Nuclear Information System (INIS)

    Zillmer, Ruediger; Livi, Roberto; Politi, Antonio; Torcini, Alessandro

    2006-01-01

    The dynamical behavior of a weakly diluted fully inhibitory network of pulse-coupled spiking neurons is investigated. Upon increasing the coupling strength, a transition from regular to stochasticlike regime is observed. In the weak-coupling phase, a periodic dynamics is rapidly approached, with all neurons firing with the same rate and mutually phase locked. The strong-coupling phase is characterized by an irregular pattern, even though the maximum Lyapunov exponent is negative. The paradox is solved by drawing an analogy with the phenomenon of 'stable chaos', i.e., by observing that the stochasticlike behavior is 'limited' to an exponentially long (with the system size) transient. Remarkably, the transient dynamics turns out to be stationary

  14. A compact rotating dilution refrigerator

    Science.gov (United States)

    Fear, M. J.; Walmsley, P. M.; Chorlton, D. A.; Zmeev, D. E.; Gillott, S. J.; Sellers, M. C.; Richardson, P. P.; Agrawal, H.; Batey, G.; Golov, A. I.

    2013-10-01

    We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 10-3 rad s-1 up to angular velocities in excess of 2.5 rad s-1. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

  15. Studies on the use of surface active agents for the removal of some pollutants from dilute aqueous solutions: foam separation techniques and sorption by sorbents synthesized from Silicious materials and surfactants

    International Nuclear Information System (INIS)

    Abd Elsalam, M.R.M.

    2010-01-01

    The increasing concern towards protection of the environment and optimization of a wide range of industrial processes and activities in both nuclear and non-nuclear fields imposes the need for the development of advanced separation processes in particular for treatment of liquid wastes and effluents.The work presented in this thesis will address the above objective with respect to the removal, from aqueous solutions, of two types of hazardous pollutants: chemical (dyes) and radiological (radionuclides) using two relatively modern separation techniques: ion flotation and adsorption onto a synthesized organo-clay. It will also include the results of treatment of dye-contaminated wastewater and mixed radioactive process wastewater, containing a toxic dye in addition to the radionuclides.The thesis comprises four chapters. Literature on dye separation by (i) ion flotation and (II) adsorption onto organo-clays are reviewed in the introductory section of chapter III and of chapter IV, respectively.

  16. Determination of microquantities of silver in platinum by isotope dilution

    International Nuclear Information System (INIS)

    Yedinakova, V.; Sladkovska, Y.

    1980-01-01

    A method is described for determining microquantities of silver in platinum. It is based on isotope dilution by means of substoichiometric extraction of dithizonates with carbon tetrachloride. The determination of silver according to this technique is not interfered by zinc or gold in quantities exceeding the silver content by one order of magnitude nor by a great excess of platinum. In the presence of copper the addition of complexon is necessary. (author)

  17. System modeling and identification in indicator dilution method for assessment of ejection fraction and pulmonary blood volume

    NARCIS (Netherlands)

    Bharath, H.N.; Prabhu, K.M.M.; Korsten, H.H.M.; Mischi, M.

    2012-01-01

    Clinically relevant cardiovascular parameters, such as pulmonary blood volume (PBV) and ejection fraction (EF), can be assessed through indicator dilution techniques. Among these techniques, which are typically invasive due to the need for central catheterization, contrast ultrasonography provides a

  18. Dynamics of dilute polymer solutions

    International Nuclear Information System (INIS)

    Nicholson, L.K.; Higgins, J.S.

    1980-01-01

    Neutrons scattered by nuclei undergoing slow motion e.g. the internal motion within polymer chains, lose or gain very small amounts of energy. It is therefore the quasi-elastic region of the neutron scattering spectrum which is of interest and in particular the time correlation function (or intermediate scattering law S(Q,t)) which is ideally required to define the motion. The neutron spin echo spectrometer (IN11) at the ILL facilitates the measurement of very small energy changes (down to 10 neV) on scattering from a sample, by changing and keeping track of neutron beam polarization non-parallel to the magnetic guide-field (1). The resultant neutron beam polarization, when normalized against a standard (totally elastic) scatterer is directly proportional to the cosine Fourier Transform of the scattering law S(Q,ω), which is to say the time correlation function is measured directly. Dilute solutions of deuterated polystyrene (PSD) and deuterated polytetrahydrofuran (PTDF) in carbon disulphide, and of their hydrogeneous counterparts (PSH and PTHF respectively) in deuterated benzene were investigated in the range 0.027 A -1 -1 , at 30 0 C. (orig./FKS)

  19. Storm Sewage Dilution in Smaller Streams

    DEFF Research Database (Denmark)

    Larsen, Torben; Vestergaard, Kristian

    1987-01-01

    A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow.......A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow....

  20. Cost effectiveness of dilute chemical decontamination

    International Nuclear Information System (INIS)

    LeSurf, J.E.; Weyman, G.D.

    The basic principles of dilute chemical decontamination are described, as well as the method of application. Methods of computing savings in radiation dose and costs are presented, with results from actual experience and illustrative examples. It is concluded that dilute chemical decontamination is beneficial in many cases. It reduces radiation exposure of workers, saves money, and simplifies maintenance work

  1. Acetone and acetaldehyde determination in tomato juice by isotopic dilution

    International Nuclear Information System (INIS)

    Piva, M.-T.; Crouzet, J.

    1977-01-01

    Acetone and acetaldehyde content of tomato juice were determined by isotope dilution techniques. The juice is added to 14 C labelled compounds, carried along by nitrogen at low pressure. The mixture of 2.4 dinitrophenylhydrazones obtained from volatile compounds is separated by thin layer chromatography on silica gel and then on alumina. A determination of radioactivity and concentration of acetone and acetaldehyde 2,4 dinitrophenylhydrazones obtained after separation and elution allow to calculate the content of these two compounds in the initial product with the same sample. This technique could be used for determination of methanol and ethanol after transformation in 3,5 dinitrobenzoates [fr

  2. Theoretical modeling of diluted antiferromagnetic systems

    International Nuclear Information System (INIS)

    Pozo, J; Elgueta, R; Acevedo, R

    2000-01-01

    Some magnetic properties of a Diluted Antiferromagnetic System (DAFS) are studied. The model of the two sub-networks for antiferromagnetism is used and a Heisenberg Hamiltonian type is proposed, where the square operators are expressed in terms of boson operators with the approach of spin waves. The behavior of the diluted system's fundamental state depends basically on the competition effect between the anisotropy field and the Weiss molecular field. The approach used allows the diluted system to be worked for strong anisotropies as well as when these are very weak

  3. Individual Tracer Atoms in an Ultracold Dilute Gas

    Science.gov (United States)

    Hohmann, Michael; Kindermann, Farina; Lausch, Tobias; Mayer, Daniel; Schmidt, Felix; Lutz, Eric; Widera, Artur

    2017-06-01

    We report on the experimental investigation of individual Cs atoms impinging on a dilute cloud of ultracold Rb atoms with variable density. We study the relaxation of the initial nonthermal state and detect the effect of single collisions which has so far eluded observation. We show that, after few collisions, the measured spatial distribution of the tracer atoms is correctly described by a Langevin equation with a velocity-dependent friction coefficient, over a large range of Knudsen numbers. Our results extend the simple and effective Langevin treatment to the realm of light particles in dilute gases. The experimental technique developed opens up the microscopic exploration of a novel regime of diffusion at the level of individual collisions.

  4. Mössbauer Studies of dilute Magnetic Semiconductors

    CERN Multimedia

    Gislason, H P; Debernardi, A; Dlamini, W B

    2002-01-01

    The recent discovery of (dilute) magnetic semiconductors with wide band gaps, e.g. GaN, ZnO and other oxides, having Curie temperatures, T$_{\\textrm{c}}$, well above room temperature, has prompted extraordinary experimental and theoretical efforts to understand, control and exploit this unexpected finding not least in view of the obvious potential of such materials for the fabrication of "spin-(elec)tronic" or magneto-optic devices. Ferromagnetism (FM) was achieved mostly by doping with dilute 3d transition metal impurities, notably Mn, Fe, and Co (in \\% concentrations), during growth or by subsequent ion implantation. However, it is fair to state that experimentally the conditions for the occurrence of ferro-, antiferro- or paramagnetism with these impurities are not yet controlled as generally at least two conflicting forms of magnetism or none have been reported for each system - albeit often produced by different techniques. Theory is challenged as "conventional" models seem to fail and no generally accep...

  5. Further development of IDGS: Isotope dilution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Li, T.K.; Parker, J.L.; Kuno, Y.; Sato, S.; Kamata, M.; Akiyama, T.

    1991-01-01

    The isotope dilution gamma-ray spectrometry (IDGS) technique for determining the plutonium concentration and isotopic composition of highly radioactive spent-fuel dissolver solutions has been further developed. Both the sample preparation and the analysis have been improved. The plutonium isotopic analysis is based on high-resolution, low-energy gamma-ray spectrometry. The plutonium concentration in the dissolver solutions then is calculated from the measured isotopic differences among the spike, the dissolver solution, and the spiked dissolver solution. Plutonium concentrations and isotopic compositions of dissolver solutions analyzed from this study agree well with those obtained by traditional isotope dilution mass spectrometry (IDMS) and are consistent with the first IDGS experimental result. With the current detector efficiency, sample size, and a 100-min count time, the estimated precision is ∼0.5% for 239 Pu and 240 Pu isotopic analyses and ∼1% for the plutonium concentration analysis. 5 refs., 2 figs., 7 tabs

  6. System for alarms analysis and optimization in petrochemicals plants; Sistema para analise e otimizacao de alarmes em plantas petroquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Gustavo; Pifer, Aderson; Guedes, Luiz Affonso [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Saito, Kaku; Aquino, Leonardo [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    The present work presents a group of algorithms, techniques and functionalities on alarms management which can be used efficiently on the treatment of 'disturbances' caused by the informal management of the alarm systems. Among the disturbances handled by these techniques, there is the recognition of intermittent alarms and false alarms, location of alarm floods and correlation between alarms, aiming the identification of communal root causes. The results will be presented through a case study on petrochemical alarm plants. At last, the results obtained by the utilization of such functionalities will be presented and discussed. (author)

  7. Dilution and separation of solids and liquids of broiler litter for supply of digester

    Energy Technology Data Exchange (ETDEWEB)

    Aires, Airon Magno; Lucas Junior, Jorge de; Xavier, Cristiane de Almeida Neves; Miranda, Adelia Pereira; Fukayama, Ellen Hatsumi [Universidade Estadual Paulista (FCAV/UNESP), Jaboticabal, SP (Brazil). Fac. de Ciencias Agrarias e Veterinarias

    2008-07-01

    The solid separation techniques indicate that it can promote a support in anaerobic biological process. This trial was realized in FCAV-UNESP, Jaboticabal, Brazil, in Rural Engineering Department. For this trial two tests were developed, using broiler litter water diluted and separated in a 3mm mesh screen: the treatments consisted in (1kg) broiler litter diluted in (2kg) of water, (1kg) broiler litter and (4kg) water, (1kg) broiler litter diluted in (6kg) of water, (1kg) broiler litter and (8kg) of water, (1kg) broiler litter diluted in (10kg) of water, (1kg) broiler litter and (12kg) water and (1kg) broiler litter diluted in (14kg) of water. Total solids (TS), solid and liquid fraction and biogas production were estimated. There were no significant differences related to solid fraction retained in screen. As the broiler litter became more diluted, a raise in the liquid fractions quantities was observed, ranging from 20.9 to 89.4% of the total diluted waste. Biogas production potentials ranged from 0.2364 to 0.4666 m{sup 3} of biogas by 100kg of liquid fraction. Organic carbon numbers ranged from 0.21 to 0.47kg by 100kg of liquid fraction and 5.36 to 6.18kg by 100kg of solid fraction. The highest values obtained for this element in liquid fractions dilutions were 2:1 and 6:1 with 0.46 and 0.47kg by 100kg respectively. The separation of liquid and solid fraction of broiler litter was viable in the smaller dilutions, because those guarantee a reduction in the anaerobic digester implementation costs and dilution water economy. Solid fraction has potential for composting, mainly in a great scale production. (author)

  8. Optimization of dose in computerized radiology exams of the hands; Otimizacao da dose em exames de radiologia computadorizada de mao

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, Ana Luiza Menegatti; Alvarez, Matheus; Alves, Allan Felipe Fattori; Dela Rosa, Maria Eugenia; Miranda, Jose Ricardo de Arruda, E-mail: analuiza@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (IBB/UNESP), Botucatu, SP (Brazil). Inst. de Biofisica. Departamento de Fisica e Biofisica; Pina, Diana Rodrigues de; Ribeiro, Sergio Marrone [Universidade Estadual Paulista Julio de Mesquita Filho (FMB/UNESP), Botucatu, SP (Brazil). Fac. de Medicina. Dept. de Doencas Tropicais e Diagnostico por Imagem; Duarte, Sergio Barbosa [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fractures and dislocations of the hand are some of the most frequently encountered injuries of the musculoskeletal system traumas. To evaluate these lesions radiography is the investigation of choice, and is rarely needed the help of other images to establish the diagnosis and treatment. The image quality of the X-ray examination is therefore essential. In this study a homogeneous phantom hand was developed for use in the hand image optimization process. In this procedure were quantified for different tissue thicknesses which are an anthropomorphic hand phantom. To perform the classification and quantification of tissue was applied membership functions in histograms of CT scans. The same procedure was adopted for 30 retrospective examinations of patients in the Hospital of the Faculty of Medicine of Botucatu UNESP (HCFMB-UNESP). The homogeneous phantom built was used to calibrate the techniques used in clinical routine (RC). Such calibrated techniques were used to acquire images of anthropomorphic phantom. These images were analyzed by Visual Grading Method (VFA) by experienced radiologists in the area. The image with better grade in AGV and lower dose was chosen as the Gold Standard. The results showed concordance between the tissue thicknesses which constitute the anthropomorphic phantom and the sample evaluated patients, with variations between 12.63% and 6.48% for soft tissue and bone, respectively. The Gold Technical Standard compared with the technique normally used in the CR reduces dose charge 41.28% and 33.18% in the tube.

  9. Analysis of structure and defects in thin silicon films deposited from hydrogen diluted silane

    International Nuclear Information System (INIS)

    Elzakker, G. van; Nadazdy, V.; Tichelaar, F.D.; Metselaar, J.W.; Zeman, M.

    2006-01-01

    Thin silicon layers have been deposited from silane diluted with hydrogen. The dilution ratio R (R = [H 2 ]/[SiH 4 ]) has been varied between R = 0 and R = 40. The structural properties of Si:H films have been studied using transmission electron microscopy imaging and Raman spectroscopy. The phase evolution from the amorphous phase into the mixed and eventually microcrystalline phase strongly depends on the hydrogen dilution. The initiation of the microcrystalline growth occurs between R = 20 and R = 25. The phase transition becomes more abrupt with increasing hydrogen dilution. Optoelectronic properties of the layers have been determined. Increasing hydrogen dilution results in films with increasing effective defect density and Urbach energy, which is related to inhomogeneous growth. The charge deep-level transient spectroscopy technique (Q-DLTS) was applied for the first time on hydrogen diluted thin silicon films in order to investigate the energy distribution of the defect states in these layers as a function of the dilution ratio R. The Q-DLTS spectra indicate a difference in defect-state distribution when the films evolve from the amorphous phase into the microcrystalline phase

  10. Development of an ultratrace analysis method for elements of the platinum group contained in environmental and geological samples using an ICP-QMS with isotope dilution analysis and suitable separation techniques; Entwicklung eines Verfahrens zur Ultraspurenbestimmung der Platingruppenelemente in Umwelt- und geologischen Proben mit einem ICP-QMS unter Verwendung der Isotopenverduennungsanalyse sowie geeigneter Separationstechniken

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, M.

    2001-07-01

    This study focussed on developing a method of ultratrace analysis for elements of the platinum group contained in environmental or geological samples using mass spectroscopic isotope dilution analysis followed by measurement on a quadrupol ICP-MS (ICP-QMSIVA). This method was subsequently used for the certification of two reference materials for environmental sampling as part of a EU project titled ''Production and certification of a road dust reference material for platinum, palladium and rhodium (PGEs) in automotive catalytic converters (PACEPAC)''. In the intercomparison round the results obtained were found to be in very good agreement with the weighted mean values of the results obtained by the other participating laboratories. The results obtained with the method developed in this study were used for the preliminary certification procedure across all elements under study without exception. In this way the present study made a substantial contribution to the successful completion of this project, and prior expectations concerning the correctness and consistency of the developed method were satisfied to the full. This is renewed confirmation of the great significance of the isotope dilution technique for the certification of reference materials, which is attributable to the highly accurate results it yields when handled properly. Comparison between CNiS dokimasia and NAA on the one hand, which was carried out in cooperation with the Nuclear Chemical Institute of Mainz University, and the present method on the other showed good agreement in terms of the decrease in Pd and Pt concentrations with growing distance from the motorway. In conjunction with the research results obtained with NAA, a well-established technique, this study shows that elements of the platinum group from automotive catalytic converters are largely emitted in metallic form. ICP-QMSIVA thus represents a very good means of keeping track of the anthropogenic deposition in the

  11. A genetic-neural artificial intelligence approach to resins optimization; Uma metodologia baseada em inteligencia artificial para otimizacao de resinas

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Denise C.; Barros, Marcio P.; Lapa, Celso M.F.; Pereira, Claudio M.N.A. [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil)]. E-mail: lapa@ien.gov.br; mbarros@ien.gov.br

    2005-07-01

    This work presents a preliminary study about the viability and adequacy of a new methodology for the definition of one of the main properties of ion exchange resins used for isotopic separation. Basically, the main problem is the definition of pelicule diameter in case of pelicular ion exchange resins, in order to achieve the best performance in the shortest time. In order to achieve this, a methodology was developed, based in two classic techniques of Artificial Intelligence (AI). At first, an artificial neural network (NN) was trained to map the existing relations between the nucleus radius and the resin's efficiency associated with the exchange time. Later on, a genetic algorithm (GA) was developed in order to find the best pelicule dimension. Preliminary results seem to confirm the potential of the method, and this can be used in any chemical process employing ion exchange resins. (author)

  12. Hydrogenated dilute nitride semiconductors theory, properties, and applications

    CERN Document Server

    Ciatto, Gianluca

    2015-01-01

    ""The electrical and optical properties of the technologically and scientifically important dilute nitride semiconductors are strongly influenced by the introduction of atomic hydrogen. This volume is an excellent summary and resource for the most recent understanding of experimental results and state-of-the-art theoretical studies of the formation, reversibility, and microscopic structure of nitrogen-hydrogen complexes in these materials. The book details how a wide variety of experimental techniques have provided a detailed understanding of the role of hydrogen. It is the premier sourc

  13. Isotope-dilution analyses of the metallic elements

    International Nuclear Information System (INIS)

    Chastagner, P.

    1982-01-01

    The isotope-dilution mass spectroscopy (IDMS) technique has proven to be to be a reliable, versatile analytical tool. Its applications seem to be limited only by the ingenuity of the investigator. Among its advantages are: small sample size; general applicability; precision and accuracy; dynamic range; simplified chemistry; determination is fixed at the time and place of isotopic homogenization. The last listed item is especially important for nuclear safeguards and processes where inventories are critical. IDMS is now a routine analytical technique in geochemical and nuclear laboratories, and in many environmental laboratories. Microgram and nanogram samples are normally used, frequently with automatic mass spectrometers, in many of these routine applications. More advanced techniques permit picogram and sub picogram samples to be analyzed, and spike to sample ratios can range from 1:1 to 1:10 12 with detection limits at attogram levels for some elements. 3 figures, 3 tables

  14. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam; Zhang, Ji; Fang, Tiegang; Roberts, William L.

    2014-01-01

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both

  15. Exergoeconomic analysis and optimization of a model cogeneration system; Analise exergoeconomica e otimizacao de um modelo de sistema de cogeracao

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Leonardo S.R. [Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, RJ (Brazil). Area de Conhecimento de Materiais e Mecanica]. E-mail: lsrv@cepel.br; Donatelli, Joao L.M. [Espirito Santo Univ., Vitoria, ES (Brazil). Dept. de Engenharia Mecanica]. E-mail: donatelli@lttc.com.ufrj.br; Cruz, Manuel E.C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica]. E-mail: manuel@serv.com.ufrj.br

    2000-07-01

    In this paper we perform exergetic and exergoeconomic analyses, a mathematical optimization and an exergoeconomic optimization of a gas turbine-heat recovery boiler cogeneration system with fixed electricity and steam production rates. The exergy balance is calculated with the IPSE pro thermal system simulation program. In the exergetic analysis, exergy destruction rates, exergetic efficiencies and structural bond coefficients for each component are evaluated as functions of the decision variables of the optimization problem. In the exergoeconomic analysis the cost for each exergetic flow is determined through cost balance equations and additional auxiliary equations from cost partition criteria. Mathematical optimization is performed by the metric variable method (software EES - Engineering Equation Solver) and by the successive quadratic programming (IMSL library - Fortran Power Station). The exergoeconomic optimization is performed on the basis of the exergoeconomic variables. System optimization is also performed by evaluating the derivative of the objective function through finite differences. This paper concludes with a comparison between the four optimization techniques employed. (author)

  16. Composite systems of dilute and dense couplings

    International Nuclear Information System (INIS)

    Raymond, J R; Saad, D

    2008-01-01

    Composite systems, where couplings are of two types, a combination of strong dilute and weak dense couplings of Ising spins, are examined through the replica method. The dilute and dense parts are considered to have independent canonical disordered or uniform bond distributions; mixing the models by variation of a parameter γ alongside inverse temperature β we analyse the respective thermodynamic solutions. We describe the variation in high temperature transitions as mixing occurs; in the vicinity of these transitions we exactly analyse the competing effects of the dense and sparse models. By using the replica symmetric ansatz and population dynamics we described the low temperature behaviour of mixed systems

  17. Computer automation of a dilution cryogenic system

    International Nuclear Information System (INIS)

    Nogues, C.

    1992-09-01

    This study has been realized in the framework of studies on developing new technic for low temperature detectors for neutrinos and dark matter. The principles of low temperature physics and helium 4 and dilution cryostats, are first reviewed. The cryogenic system used and the technic for low temperature thermometry and regulation systems are then described. The computer automation of the dilution cryogenic system involves: numerical measurement of the parameter set (pressure, temperature, flow rate); computer assisted operating of the cryostat and the pump bench; numerical regulation of pressure and temperature; operation sequence full automation allowing the system to evolve from a state to another (temperature descent for example)

  18. Interaction Studies of Dilute Aqueous Oxalic Acid

    Directory of Open Access Journals (Sweden)

    Kiran Kandpal

    2007-01-01

    Full Text Available Molecular conductance λm, relative viscosity and density of oxalicacid at different concentration in dilute aqueous solution were measured at 293 K.The conductance data were used to calculate the value association constant.Viscosity and density data were used to calculate the A and B coefficient ofJone-Dole equation and apparent molar volume respectively. The viscosityresults were utilized for the applicability of Modified Jone-Dole equation andStaurdinger equations. Mono oxalate anion acts, as structure maker and thesolute-solvent interaction were present in the dilute aqueous oxalic acid.

  19. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  20. Diluted magnetic semiconductor nanowires exhibiting magnetoresistance

    Science.gov (United States)

    Yang, Peidong [El Cerrito, CA; Choi, Heonjin [Seoul, KR; Lee, Sangkwon [Daejeon, KR; He, Rongrui [Albany, CA; Zhang, Yanfeng [El Cerrito, CA; Kuykendal, Tevye [Berkeley, CA; Pauzauskie, Peter [Berkeley, CA

    2011-08-23

    A method for is disclosed for fabricating diluted magnetic semiconductor (DMS) nanowires by providing a catalyst-coated substrate and subjecting at least a portion of the substrate to a semiconductor, and dopant via chloride-based vapor transport to synthesize the nanowires. Using this novel chloride-based chemical vapor transport process, single crystalline diluted magnetic semiconductor nanowires Ga.sub.1-xMn.sub.xN (x=0.07) were synthesized. The nanowires, which have diameters of .about.10 nm to 100 nm and lengths of up to tens of micrometers, show ferromagnetism with Curie temperature above room temperature, and magnetoresistance up to 250 Kelvin.

  1. Optimization of radiation protection in gamma radiography facilities; Otimizacao do sistema de radioprotecao nas instalacoes radiograficas de gamagrafia

    Energy Technology Data Exchange (ETDEWEB)

    Antonio Filho, Joao

    1999-07-01

    To determine optimized dose limits for workers, a study of optimization of radiation protection was undertaken in gamma radiography facilities closed, using the Technique Multiple Attributes Utility Analysis. A total of 217 protection options, distributed in 34 irradiation scenarios for tree facility types ( fixed open, moveable and closed (bunker) were analyzed. In the determination of the optimized limit dose, the following attributes were considered; costs of the protection barriers, costs attributed to the biological detriment for different alpha (the reference value of unit collective dose), size of the isolation area, constrained limits dose of annual individual equivalent doses and collective dose. The variables studied in the evaluation included: effective work load, type and activity of the sources of radiation ({sup 192}Ir and {sup 60}Co), source-operator distance related to the characteristic of the length of the command cable and the guide tube, type and thickness of the materials used in the protection barriers (concrete, barite, ceramic, lead, steel alloy and tungsten). The optimal analytic solutions obtained in the optimization process that resulted in the indication of the optimized dose limit were determined by means of a sensitivity analysis and by direct and logic evaluations, thus, independent of the values of the monetary coefficient attributed to the biological detriment, of the annual interest rate applied to the protection cost and of the type of installation studied, it was concluded that the primary limit of annual equivalent dose for workers (now 50 mSv) can be easily reduced to an optimized annual dose limit of 5 mSv. (author)

  2. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    International Nuclear Information System (INIS)

    Pereira, L M C

    2017-01-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials. (topical review)

  3. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    Science.gov (United States)

    Pereira, L. M. C.

    2017-10-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials.

  4. Quantifying dilution caused by execution efficiency

    Directory of Open Access Journals (Sweden)

    Taís Renata Câmara

    Full Text Available Abstract In open pit mining, dilution is not always a factor systematically analyzed and calculated. Often it is only an adjusted number, for example, calculated or even empirically determined for a certain operational condition perpetuating along time in the form of a constant applied to calculating reserves or mine planning in attendance of audit requirements. Dilution and loss are factors that should be always considered for tonnage and grade estimates. These factors are always associated and can be determined considering several particularities of the deposit and the operation itself. In this study, a methodology was determined to identify blocks adjacent to the blocks previously planned to be mined. Thus, it is possible to estimate the dilution caused by poor operating efficiency, taking into account the inability of the equipment to perfectly remove each block, respecting its limits. Mining dilution is defined as the incorporation of waste material to ore due to the operational incapacity to efficiently separate the materials during the mining process, considering the physical processes, and the operating and geometric configurations of the mining with the equipment available.

  5. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    be attributed to the reliability of the measured distances which fall off quickly with each shell. Therefore, in ... field and electrical field gradients due to impurities in vanadium [13]. The effective .... Expanding ∆φ(| Rn' |) in power series of u(R0 n), one gets ... The results of each dilute alloy system are presented separately and ...

  6. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    We present here a systematic investigation of the atomic displacements in bcc transition metal (TM) dilute alloys. We have calculated the atomic displacements in bcc (V, Cr, Fe, Nb, Mo, Ta and W) transition metals (TMs) due to 3d, 4d and 5d TMs at the substitutional site using the Kanzaki lattice static method. Wills and ...

  7. Continuous deionization of a dilute nickel solution

    NARCIS (Netherlands)

    Spoor, P.B.; Koene, L.; Veen, ter W.R.; Janssen, L.J.J.

    2002-01-01

    This paper describes the continuous removal of nickel ions from a dilute solution using a hybrid ion-exchange/electrodialysis process. Emphasis was placed on the ionic state of the bed during the process, and the mass balance of ions in the system. Much of this information was obtained by analysing

  8. Dilution kicker for the SPS beam dump

    CERN Multimedia

    1974-01-01

    In order to reduce thermal stress on the SPS dump material, the fast-ejected beam was swept horizontally across the dump. This was done with the "dilution kicker" MKDH, still in use at the time of writing. The person on the left is Manfred Mayer. See also 7404072X.

  9. Magnetic properties of diluted magnetic semiconductors

    NARCIS (Netherlands)

    Jonge, de W.J.M.; Swagten, H.J.M.

    1991-01-01

    A review will be given of the magnetic characteristics of diluted magnetic semiconductors and the relation with the driving exchange mechanisms. II–VI as well as IV–VI compounds will be considered. The relevance of the long-range interaction and the role of the carrier concentration will be

  10. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  11. Fractal effects on excitations in diluted ferromagnets

    International Nuclear Information System (INIS)

    Kumar, D.

    1981-08-01

    The low energy spin-wave like excitations in diluted ferromagnets near percolation threshold are studied. For this purpose an explicit use of the fractal model for the backbone of the infinite percolating cluster due to Kirkpatrick is made. Three physical effects are identified, which cause the softening of spin-waves as the percolation point is approached. The importance of fractal effects in the calculation of density of states and the low temperature thermodynamics is pointed out. (author)

  12. Dilution physics modeling: Dissolution/precipitation chemistry

    International Nuclear Information System (INIS)

    Onishi, Y.; Reid, H.C.; Trent, D.S.

    1995-09-01

    This report documents progress made to date on integrating dilution/precipitation chemistry and new physical models into the TEMPEST thermal-hydraulics computer code. Implementation of dissolution/precipitation chemistry models is necessary for predicting nonhomogeneous, time-dependent, physical/chemical behavior of tank wastes with and without a variety of possible engineered remediation and mitigation activities. Such behavior includes chemical reactions, gas retention, solids resuspension, solids dissolution and generation, solids settling/rising, and convective motion of physical and chemical species. Thus this model development is important from the standpoint of predicting the consequences of various engineered activities, such as mitigation by dilution, retrieval, or pretreatment, that can affect safe operations. The integration of a dissolution/precipitation chemistry module allows the various phase species concentrations to enter into the physical calculations that affect the TEMPEST hydrodynamic flow calculations. The yield strength model of non-Newtonian sludge correlates yield to a power function of solids concentration. Likewise, shear stress is concentration-dependent, and the dissolution/precipitation chemistry calculations develop the species concentration evolution that produces fluid flow resistance changes. Dilution of waste with pure water, molar concentrations of sodium hydroxide, and other chemical streams can be analyzed for the reactive species changes and hydrodynamic flow characteristics

  13. Angio-RM das artérias carótidas e vertebrais: análise de diferentes técnicas de volume e diluição de contraste em aparelho de 1,0 t e gradiente de 15 mt/m Contrast-enhanced MR angiography of the carotid and vertebral arteries: analysis of different contrast volumes and dilution techniques at 1.0 T with 15 mT/m gradient.

    Directory of Open Access Journals (Sweden)

    Luiz Guilherme C. Hartmann

    2001-08-01

    Full Text Available OBJETIVO: Avaliar as artérias cervicais (carótidas e vertebrais por meio da angio-RM, utilizando-se diferentes dosagens e diluições de contraste paramagnético. MATERIAIS E MÉTODOS: Estudo prospectivo em 15 pacientes, com análise de 30 artérias carótidas comuns, 30 artérias carótidas internas, 30 artérias carótidas externas e 30 artérias vertebrais, utilizando-se diferentes volumes e dosagens de contraste paramagnético: grupo I - dose única (14 ml de Gd-DTPA; grupo II -dose dupla (28 ml de Gd-DTPA; grupo III - dose única e diluída a 50%. A injeção de contraste foi realizada com a utilização de bomba injetora e com velocidades de injeção de 2 ml/s (grupo I e 3 ml/s (grupos II e III. Os segmentos arteriais foram analisados por três examinadores em consenso de forma subjetiva, avaliando-se o grau de visibilidade, intensidade de contrastação e definição de seus contornos. RESULTADOS: Em todos os itens analisados os pacientes do grupo II apresentaram melhor resultado (visibilização total, boa contrastação dos vasos e contornos bem definidos. No grupo I houve boa visibilização das artérias carótidas e vertebrais, porém a intensidade de contraste e a definição dos contornos apresentaram variabilidade qualitativa. O grupo III apresentou os piores resultados, com dificuldade de visibilização, intensidade de contrastação baixa e contornos mal definidos. CONCLUSÃO: Entre os grupos analisados, a técnica utilizando dose dupla de gadolínio é a que permite melhor avaliação das artérias cervicais. A utilização de contraste diluído prejudica a avaliação dos vasos do pescoço.PURPOSE: To evaluate the carotid and vertebral arteries by magnetic resonance angiography, using different contrast volumes and dilution techniques. SUBJECTS AND METHODS: Prospective study of 15 patients, which included the evaluation of 30 common carotid arteries, 30 internal carotid arteries, 30 external carotid arteries and 30

  14. Isotope dilution mass spectrometry for nuclear material accountability measurements: dreams and reality

    International Nuclear Information System (INIS)

    Deron, S.; )

    1996-01-01

    Gravimetry, titration, coulometry and isotope dilution mass spectrometry are alternative techniques which can be used to obtain elemental assays of the desirable accuracy. The communication briefly describes the characteristics of the procedure and summarizes a wealth of experience accumulated during actual accountability verification activities

  15. Diluted Ising spin 1/2 lattice with an arbitrary coordination number

    International Nuclear Information System (INIS)

    Bach Thanh Cong; El Amraoui, Y.

    1993-01-01

    A useful representation for the Callen identity in the case of spin 1/2 is introduced by a simple technique. The phase diagrams, percolation problems of the diluted Ising lattice with arbitrary coordination number z are also discussed. (author). 12 refs, 5 figs

  16. Molecular analysis of two mouse dilute locus deletion mutations: Spontaneous dilute lethal20J and radiation-induced dilute prenatal lethal Aa2 alleles

    International Nuclear Information System (INIS)

    Strobel, M.C.; Seperack, P.K.; Copeland, N.G.; Jenkins, N.A.

    1990-01-01

    The dilute (d) coat color locus of mouse chromosome 9 has been identified by more than 200 spontaneous and mutagen-induced recessive mutations. With the advent of molecular probes for this locus, the molecular lesion associated with different dilute alleles can be recognized and precisely defined. In this study, two dilute mutations, dilute-lethal20J (dl20J) and dilute prenatal lethal Aa2, have been examined. Using a dilute locus genomic probe in Southern blot analysis, we detected unique restriction fragments in dl20J and Aa2 DNA. Subsequent analysis of these fragments showed that they represented deletion breakpoint fusion fragments. DNA sequence analysis of each mutation-associated deletion breakpoint fusion fragment suggests that both genomic deletions were generated by nonhomologous recombination events. The spontaneous dl20J mutation is caused by an interstitial deletion that removes a single coding exon of the dilute gene. The correlation between this discrete deletion and the expression of all dilute-associated phenotypes in dl20J homozygotes defines the dl20J mutation as a functional null allele of the dilute gene. The radiation-induced Aa2 allele is a multilocus deletion that, by complementation analysis, affects both the dilute locus and the proximal prenatal lethal-3 (pl-3) functional unit. Molecular analysis of the Aa2 deletion breakpoint fusion fragment has provided access to a previously undefined gene proximal to d. Initial characterization of this new gene suggests that it may represent the genetically defined pl-3 functional unit

  17. Crystallization of calcium oxalate in minimally diluted urine

    Science.gov (United States)

    Bretherton, T.; Rodgers, A.

    1998-09-01

    Crystallization of calcium oxalate was studied in minimally diluted (92%) urine using a mixed suspension mixed product crystallizer in series with a Malvern particle sizer. The crystallization was initiated by constant flow of aqueous sodium oxalate and urine into the reaction vessel via two independent feed lines. Because the Malvern cell was in series with the reaction vessel, noninvasive measurement of particle sizes could be effected. In addition, aliquots of the mixed suspension were withdrawn and transferred to a Coulter counter for crystal counting and sizing. Steady-state particle size distributions were used to determine nucleation and growth kinetics while scanning electron microscopy was used to examine deposited crystals. Two sets of experiments were performed. In the first, the effect of the concentration of the exogenous sodium oxalate was investigated while in the second, the effect of temperature was studied. Calcium oxalate nucleation and growth rates were found to be dependent on supersaturation levels inside the crystallizer. However, while growth rate increased with increasing temperature, nucleation rates decreased. The favored phases were the trihydrate at 18°C, the dihydrate at 38° and the monohydrate at 58°C. The results of both experiments are in agreement with those obtained in other studies that have been conducted in synthetic and in maximally diluted urine and which have employed invasive crystal counting and sizing techniques. As such, the present study lends confidence to the models of urinary calcium oxalate crystallization processes which currently prevail in the literature.

  18. Relative volatility of dilute solutions of Rb-Cs system

    International Nuclear Information System (INIS)

    Gromov, P.B.; Izotov, V.P.; Nisel'son, L.A.

    1984-01-01

    Relative volatility of diluted solutions Rb-Cs in the temperature range 650-820 K and pressures 13-200 gPa has been studied. The system Rb-Cs in the range of diluted solutions obeys the Henry law. It is shown, that liquid-vapour equilibrium in diluted solutions of cesium in rubidium is characterized by negative deviation from perfection

  19. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  20. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  1. Development of the Melt-Dilute Treatment Technology for Al-Based DOE Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Peacock, H.B.; Adams, T.M.; Iyer, N.C.

    1998-09-01

    Spent foreign and domestic research reactor fuel assemblies will be sent to Savannah River Site and prepared for interim and eventual geologic storage. Many of the fuel plates have been made with high enriched uranium, and during long term storage, the integrity of the fuel maybe effected if the canister is breached. To reduce the potential for criticality, proliferation, and reduce storage volume, a new treatment technology called melt-dilute is being developed at SRS. The technique will melt the spent fuel assemblies and will dilute the isotopic content to below 20%. The process is simple and versatile

  2. The phase diagrams of the site-diluted spin-1/2 Ising superlattice

    International Nuclear Information System (INIS)

    Saber, A.; Essaoudi, I.; Ainane, A.; Dujardin, F.; Saber, M.; Stebe, B.

    1998-08-01

    Using the effective field theory with a probability distribution technique that accounts for the single-site spin correlations, the critical behavior of a diluted spin-1/2 Ising superlattice consisting of two different ferromagnet materials is examined. The critical temperature of the system is studied as a function of the thickness of the constituents in a unit cell, the concentration of magnetic atoms, and the exchange interactions in each material. It is shown that the properties of the diluted system are different from those of the corresponding pure system. (author)

  3. Use of image analysis for monitoring the dilution of Physalis peruviana pulp

    Directory of Open Access Journals (Sweden)

    Silvana Licodiedoff

    2013-06-01

    Full Text Available The aim of this work was to develop linear models using the image analysis coupled with density measurements to monitor the dilution of the Physalis juice in the concentrations ranging from 0 to 100% in mass of juice pulp. A sample corresponding to 20% in the mass of juice pulp was for validating purposes and a prediction of 19.9±0.3%. The models with three parameters showed the best predictions, providing this technique with a promising future for the monitoring the dilution of fruit juices.

  4. Axion cosmology, lattice QCD and the dilute instanton gas

    International Nuclear Information System (INIS)

    Borsanyi, S.; Fodor, Z.; Mages, S.W.; Nogradi, D.; Szabo, K.K.

    2015-08-01

    Axions are one of the most attractive dark matter candidates. The evolution of their number density in the early universe can be determined by calculating the topological susceptibility χ(T) of QCD as a function of the temperature. Lattice QCD provides an ab initio technique to carry out such a calculation. A full result needs two ingredients: physical quark masses and a controlled continuum extrapolation from non-vanishing to zero lattice spacings. We determine χ(T) in the quenched framework (infinitely large quark masses) and extrapolate its values to the continuum limit. The results are compared with the prediction of the dilute instanton gas approximation (DIGA). A nice agreement is found for the temperature dependence, whereas the overall normalization of the DIGA result still differs from the non-perturbative continuum extrapolated lattice results by a factor of order ten. We discuss the consequences of our findings for the prediction of the amount of axion dark matter.

  5. Field measurement program to determine far field plume dilution parameters

    International Nuclear Information System (INIS)

    Orth, R.C.; Carter, H.H.; Miyasaki, M.T.

    1974-01-01

    A description of the techniques used to obtain measurements of temperature, salinity, tidal velocity and tracer concentration required to determine the far field dilution in a shallow estuary is presented. The study was done to characterize the physical hydrography of the Bush River, a tributary estuary of the Chesapeake Bay, which is a possible recipient of the thermal discharge from a proposed power plant consisting of two 850 MWe nuclear generating units. Measurements of temperature and salinity along the axis of the estuary during periods of high and low fresh water inflow were obtained for use in the development of a one-dimensional-segmented transient state model of the estuary. Computer concentrations from the model compared favorably with measured dye concentrations for the same periods of high and low freshwater inflow

  6. Forms of vitamin B12 in radioisotope dilution assays

    International Nuclear Information System (INIS)

    Begley, J.A.; Hall, C.A.

    1981-01-01

    Since the presence of analogues of vitamin B 12 (B 12 , cobalamin, Cbl) has been postulated as the basis for the high values obtained by some radioisotope dilution assays (RIDA) of serum Cbl, serum was examined for analogues. None could be demonstrated in the extracts of serum prepared for RIDA as sought by both direct and indirect techniques. The natural forms of serum Cbl were converted to cyanocobalamin (CN Cbl) by this process of extraction which included cyanide (CN). The correctly performed RIDA for Cbl based on R binder gave higher values than a RIDA based on intrinsic factor or than by bioassay. By exclusion, the difference appeared to be due to unidentified factors rather than the presence of analogues. (author)

  7. Dilute scintillators for large-volume tracking detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reeder, R.A. (University of New Mexico, Albuquerque, NM (United States)); Dieterle, B.D. (University of New Mexico, Albuquerque, NM (United States)); Gregory, C. (University of New Mexico, Albuquerque, NM (United States)); Schaefer, F. (University of New Mexico, Albuquerque, NM (United States)); Schum, K. (University of New Mexico, Albuquerque, NM (United States)); Strossman, W. (University of California, Riverside, CA (United States)); Smith, D. (Embry-Riddle Aeronautical Univ., Prescott, AZ (United States)); Christofek, L. (Los Alamos National Lab., NM (United States)); Johnston, K. (Los Alamos National Lab., NM (United States)); Louis, W.C. (Los Alamos National Lab., NM (United States)); Schillaci, M. (Los Alamos National Lab., NM (United States)); Volta, M. (Los Alamos National Lab., NM (United States)); White, D.H. (Los Alamos National Lab., NM (United States)); Whitehouse, D. (Los Alamos National Lab., NM (United States)); Albert, M. (University of Pennsylvania, Phi

    1993-10-01

    Dilute scintillation mixtures emit isotropic light for both fast and slow particles, but retain the Cherenkov light cone from fast particles. Large volume detectors using photomultipliers to reconstruct relativistic tracks will also be sensitive to slow particles if they are filled with these mixtures. Our data show that 0.03 g/l of b-PBD in mineral oil has a 2.4:1 ratio (in the first 12 ns) of isotropic light to Cherenkov light for positron tracks. The light attenuation length is greater than 15 m for wavelength above 400 nm, and the scintillation decay time is about 2 ns for the fast component. There is also a slow isotropic light component that is larger (relative to the fast component) for protons than for electrons. This effect allows particle identification by a technique similar to pulse shape discrimination. These features will be utilized in LSND, a neutrino detector at LAMPF. (orig.)

  8. The phase diagrams and the order parameters of the diluted superlattice with antiferromagnetic interface coupling

    International Nuclear Information System (INIS)

    Oubelkacem, A.; El Aouad, N.; Bentaleb, M.; Laaboudi, B.; Saber, M.

    2004-01-01

    Using the effective field theory with a probability distribution technique that accounts for the self-spin correlation functions, the magnetic properties of the diluted Ising superlattice consisting of two ferromagnetic materials A and B, with L a layers of diluted spins S a =((1)/(2)) and L b layers of diluted spins S b =1 with antiferromagnetic interface coupling are examined. For fixed values of the reduced exchange interactions and the concentration c of magnetic atoms, the phase diagrams, the two sublattice magnetizations and the total magnetization for the superlattice with the same spin S a =S b =((1)/(2)) and for S a =((1)/(2)), S b =1 are studied as a function of the temperature. We find a number of characteristic phenomena. In particular, the effect of the concentration c of magnetic atoms, the interlayer coupling and the layer thickness on both the compensation temperature and the magnetization profiles are clarified

  9. Polaron in the dilute critical Bose condensate

    Science.gov (United States)

    Pastukhov, Volodymyr

    2018-05-01

    The properties of an impurity immersed in a dilute D-dimensional Bose gas at temperatures close to its second-order phase transition point are considered. Particularly by means of the 1/N-expansion, we calculate the leading-order polaron energy and the damping rate in the limit of vanishing boson–boson interaction. It is shown that the perturbative effective mass and the quasiparticle residue diverge logarithmically in the long-length limit, signalling the non-analytic behavior of the impurity spectrum and pole-free structure of the polaron Green’s function in the infrared region, respectively.

  10. Confluence Model or Resource Dilution Hypothesis?

    DEFF Research Database (Denmark)

    Jæger, Mads

    have a negative effect on educational attainment most studies cannot distinguish empirically between the CM and the RDH. In this paper, I use the different theoretical predictions in the CM and the RDH on the role of cognitive ability as a partial or complete mediator of the sibship size effect......Studies on family background often explain the negative effect of sibship size on educational attainment by one of two theories: the Confluence Model (CM) or the Resource Dilution Hypothesis (RDH). However, as both theories – for substantively different reasons – predict that sibship size should...

  11. Optical spacing effect in organic photovoltaic cells incorporating a dilute acceptor layer

    Energy Technology Data Exchange (ETDEWEB)

    Menke, S. Matthew; Lindsay, Christopher D.; Holmes, Russell J. [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-06-16

    The addition of spacing layers in organic photovoltaic cells (OPVs) can enhance light absorption by optimizing the spatial distribution of the incident optical field in the multilayer structure. We explore the optical spacing effect in OPVs achieved using a diluted electron acceptor layer of C{sub 60}. While optical spacing is often realized by optimizing buffer layer thickness, we find that optical spacing via dilution leads to cells with similar or enhanced photocurrent. This is observed despite a smaller quantity of absorbing molecules, suggesting a more efficient use of absorbed photons. In fact, dilution is found to concentrate optical absorption near the electron donor-acceptor interface, resulting in a marked increase in the exciton diffusion efficiency. Contrasting the use of changes in thickness to engineer optical absorption, the use of dilution does not significantly alter the overall thickness of the OPV. Optical spacing via dilution is shown to be a viable alternative to more traditional optical spacing techniques and may be especially useful in the continued optimization of next-generation, tandem OPVs where it is important to minimize competition for optical absorption between individual sub-cells.

  12. Optical spacing effect in organic photovoltaic cells incorporating a dilute acceptor layer

    International Nuclear Information System (INIS)

    Menke, S. Matthew; Lindsay, Christopher D.; Holmes, Russell J.

    2014-01-01

    The addition of spacing layers in organic photovoltaic cells (OPVs) can enhance light absorption by optimizing the spatial distribution of the incident optical field in the multilayer structure. We explore the optical spacing effect in OPVs achieved using a diluted electron acceptor layer of C 60 . While optical spacing is often realized by optimizing buffer layer thickness, we find that optical spacing via dilution leads to cells with similar or enhanced photocurrent. This is observed despite a smaller quantity of absorbing molecules, suggesting a more efficient use of absorbed photons. In fact, dilution is found to concentrate optical absorption near the electron donor-acceptor interface, resulting in a marked increase in the exciton diffusion efficiency. Contrasting the use of changes in thickness to engineer optical absorption, the use of dilution does not significantly alter the overall thickness of the OPV. Optical spacing via dilution is shown to be a viable alternative to more traditional optical spacing techniques and may be especially useful in the continued optimization of next-generation, tandem OPVs where it is important to minimize competition for optical absorption between individual sub-cells.

  13. Nutritional assessment by isotope dilution analysis of body composition

    International Nuclear Information System (INIS)

    Szeluga, D.J.; Stuart, R.K.; Utermohlen, V.; Santos, G.W.

    1984-01-01

    The three components of body mass, body cell mass (BCM), extracellular fluid (ECF), and fat + extracellular solids (ECS: bone, tendon, etc) can be quantified using established isotope dilution techniques. With these techniques, total body water (TBW) and ECF are measured using 3H 2 O and 82 Bromine, respectively, as tracers. BCM is calculated from intracellular fluid (ICF) where ICF . TBW - ECF. Fat + ECS is estimated as: body weight - (BCM + ECF). TBW and ECF can be determined by either of two calculation methods, one requiring several timed plasma samples (extrapolation method) and one requiring a single plasma sample and a 4-h urine collection (urine-corrected method). The comparability of the two calculation methods was evaluated in 20 studies in 12 bone marrow transplant recipients. We found that for determination of TBW and ECF there was a very strong linear relationship (r2 greater than 0.98) between the calculation methods. Further comparisons (by t test, 2-sided) indicated that for the determination of ECF, the methods were not significantly (p greater than 0.90) different; however, TBW determined by the urine-corrected method was slightly (0.1 to 6%), but significantly (p less than 0.01) greater than that determined by the extrapolation method. Therefore, relative to the extrapolation method, the urine-corrected method ''over-estimates'' BCM and ''under-estimates'' fat + ECS since determination of these compartment sizes depends on measurement of TBW. We currently use serial isotope dilution studies to monitor the body composition changes of patients receiving therapeutic nutritional support

  14. The Statistical Mechanics of Dilute, Disordered Systems

    Science.gov (United States)

    Blackburn, Roger Michael

    Available from UMI in association with The British Library. Requires signed TDF. A graph partitioning problem with variable inter -partition costs is studied by exploiting its mapping on to the Ashkin-Teller spin glass. The cavity method is used to derive the TAP equations and free energy for both extensively connected and dilute systems. Unlike Ising and Potts spin glasses, the self-consistent equation for the distribution of effective fields does not have a solution solely made up of delta functions. Numerical integration is used to find the stable solution, from which the ground state energy is calculated. Simulated annealing is used to test the results. The retrieving activity distribution for networks of boolean functions trained as associative memories for optimal capacity is derived. For infinite networks, outputs are shown to be frozen, in contrast to dilute asymmetric networks trained with the Hebb rule. For finite networks, a steady leaking to the non-retrieving attractor is demonstrated. Simulations of quenched networks are reported which show a departure from this picture: some configurations remain frozen for all time, while others follow cycles of small periods. An estimate of the critical capacity from the simulations is found to be in broad agreement with recent analytical results. The existing theory is extended to include noise on recall, and the behaviour is found to be robust to noise up to order 1/c^2 for networks with connectivity c.

  15. Universal water-dilutable inhibited protective lubricants

    International Nuclear Information System (INIS)

    Mamtseva, M.V.; Kardash, N.V.; Latynina, M.B.

    1993-01-01

    In the interest of environmental protection, improvement of working conditions, and reduced fire hazard in production operations, water-based protective lubricants are now available in a wide assortment, and the production volume has increased greatly. The term water-dilutable inhibited protective lubricants (WDIPL) means water-soluble, water-emulsifiable, or water-dispersible products with the dual function of reducing friction and wear and protecting metal surfaces against corrosion for specified periods of time. According to the standard Unified System of Protection Against Corrosion and Aging (COST 9.103-78), WDIPLs are classed as products for the temporary corrosion protection of metals and end-items. In the general class of WDIPLs one can identify water-dilutable combination corrosion inhibitors, film-forming inhibited petroleum compositions (FIPC-d), detergent-preservative fluids, operational-preservative lubricating-cooling process compounds (ICPC), and, finally, universal multifunctional products. Combined corrosion inhibitors may consist of water-soluble organic and inorganic compounds; water/oil and oil-soluble surfactants - corrosion inhibitors of the chemisorption type or donor and/or acceptor types; shielding inhibitors of the adsorption type; and fast-acting water-displacing components. 23 refs

  16. Capsize of polarization in dilute photonic crystals.

    Science.gov (United States)

    Gevorkian, Zhyrair; Hakhoumian, Arsen; Gasparian, Vladimir; Cuevas, Emilio

    2017-11-29

    We investigate, experimentally and theoretically, polarization rotation effects in dilute photonic crystals with transverse permittivity inhomogeneity perpendicular to the traveling direction of waves. A capsize, namely a drastic change of polarization to the perpendicular direction is observed in a one-dimensional photonic crystal in the frequency range 10 ÷ 140 GHz. To gain more insights into the rotational mechanism, we have developed a theoretical model of dilute photonic crystal, based on Maxwell's equations with a spatially dependent two dimensional inhomogeneous dielectric permittivity. We show that the polarization's rotation can be explained by an optical splitting parameter appearing naturally in Maxwell's equations for magnetic or electric fields components. This parameter is an optical analogous of Rashba like spin-orbit interaction parameter present in quantum waves, introduces a correction to the band structure of the two-dimensional Bloch states, creates the dynamical phase shift between the waves propagating in the orthogonal directions and finally leads to capsizing of the initial polarization. Excellent agreement between theory and experiment is found.

  17. Field ionization mass spectrometry (FIMS) applied to tracer studies and isotope dilution analysis

    International Nuclear Information System (INIS)

    Anbar, M.; Heck, H.d'A.; McReynolds, J.H.; St John, G.A.

    1975-01-01

    The nonfragmenting nature of field ionization mass spectrometry makes it a preferred technique for the isotopic analysis of multilabeled organic compounds. The possibility of field ionization of nonvolatile thermolabile materials significantly extends the potential uses of this technique beyond those of conventional ionization methods. Multilabeled tracers may be studied in biological systems with a sensitivity comparable to that of radioactive tracers. Isotope dilution analysis may be performed reliably by this technique down to picogram levels. These techniques will be illustrated by a number of current studies using multilabeled metabolites and drugs. The scope and limitations of the methodology are discussed

  18. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  19. Alpha-clustering in dilute nucleonic sea

    International Nuclear Information System (INIS)

    Tohsaki, Akihiro

    1999-01-01

    α-clusters are expected to come out here and there in nucleonic sea owing to energetic benefit as its density is diluted. We propose a precise treatment to elucidate α-clusterized process in nucleonic sea after the breakdown of the uniformness. In order to do this, an infinite number of nucleons are considered by taking account of both the Pauli exclusion principle and effective internucleon forces. This method is called a microscopic approach, which has been successful in an α-cluster structure in light nuclei. In particular, we shed light on overcoming difficulties in a static model within the microscopic framework. This improvement is verified by using the empirical value in Weizaecker's mass formula. (author)

  20. Water Metabolism of Walruses by Isotope Dilution

    DEFF Research Database (Denmark)

    Acquarone, M.; Born, E. W.; Chwalibog, A.

    was sampled via an epidural catheter, at regular intervals, for up to seven hours after the initial enrichment to assess isotope equilibration in the body water pools. Five individuals returned to the haul-out after feeding trips of varying duration (158±86 hr, 44-287 hr) where they were immobilized again......In August 2000, the hydrogen isotope dilution method was used on 7 adult male Atlantic walruses (Odobenus rosmarus rosmarus) (weight: 1197±148 kg, mean±SD, range 1013-1508 kg) at a terrestrial haul-out in Northeastern Greenland to determine their body water pool sizes and body water turnover rates....... During immobilization by use of etorphine HCl (reversed with diprenorphine HCl), a first blood sample was taken to measure background isotope levels. The animals were then enriched with deuterium oxide by infusion into the epidural vein. During recovery, while the animals were still on the beach, blood...

  1. Tunnel backfill erosion by dilute water

    Energy Technology Data Exchange (ETDEWEB)

    Olin, M. [VTT Technical Research Centre of Finland, Espoo (Finland)

    2014-03-15

    The goal was to estimate smectite release from tunnel backfill due to dilute groundwater pulse during post glacial conditions. The plan was to apply VTT's two different implementations (BESW{sub D} and BESW{sub S}) of well-known model of Neretnieks et al. (2009). It appeared difficult to produce repeatable results using this model in COMSOL 4.2 environment, therefore a semi-analytical approximate approach was applied, which enabled to take into account both different geometry and smectite content in tunnel backfill as compared to buffer case. The results are quite similar to buffer results due to the decreasing effect of smaller smectite content and the increasing effect of larger radius. (orig.)

  2. Ultrafast magnetization dynamics in diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Morandi, O [INRIA Nancy Grand-Est and Institut de Recherche en Mathematiques Avancees, 7 rue Rene Descartes, F-67084 Strasbourg (France); Hervieux, P-A; Manfredi, G [Institut de Physique et Chimie des Materiaux de Strasbourg, 23 rue du Loess, F-67037 Strasbourg (France)], E-mail: morandi@dipmat.univpm.it

    2009-07-15

    We present a dynamical model that successfully explains the observed time evolution of the magnetization in diluted magnetic semiconductor quantum wells after weak laser excitation. Based on the pseudo-fermion formalism and a second-order many-particle expansion of the exact p-d exchange interaction, our approach goes beyond the usual mean-field approximation. It includes both the sub-picosecond demagnetization dynamics and the slower relaxation processes that restore the initial ferromagnetic order in a nanosecond timescale. In agreement with experimental results, our numerical simulations show that, depending on the value of the initial lattice temperature, a subsequent enhancement of the total magnetization may be observed within the timescale of a few hundred picoseconds.

  3. Tunnel backfill erosion by dilute water

    International Nuclear Information System (INIS)

    Olin, M.

    2014-03-01

    The goal was to estimate smectite release from tunnel backfill due to dilute groundwater pulse during post glacial conditions. The plan was to apply VTT's two different implementations (BESW D and BESW S ) of well-known model of Neretnieks et al. (2009). It appeared difficult to produce repeatable results using this model in COMSOL 4.2 environment, therefore a semi-analytical approximate approach was applied, which enabled to take into account both different geometry and smectite content in tunnel backfill as compared to buffer case. The results are quite similar to buffer results due to the decreasing effect of smaller smectite content and the increasing effect of larger radius. (orig.)

  4. Critical exponents for diluted resistor networks.

    Science.gov (United States)

    Stenull, O; Janssen, H K; Oerding, K

    1999-05-01

    An approach by Stephen [Phys. Rev. B 17, 4444 (1978)] is used to investigate the critical properties of randomly diluted resistor networks near the percolation threshold by means of renormalized field theory. We reformulate an existing field theory by Harris and Lubensky [Phys. Rev. B 35, 6964 (1987)]. By a decomposition of the principal Feynman diagrams, we obtain diagrams which again can be interpreted as resistor networks. This interpretation provides for an alternative way of evaluating the Feynman diagrams for random resistor networks. We calculate the resistance crossover exponent phi up to second order in epsilon=6-d, where d is the spatial dimension. Our result phi=1+epsilon/42+4epsilon(2)/3087 verifies a previous calculation by Lubensky and Wang, which itself was based on the Potts-model formulation of the random resistor network.

  5. A horizontal dilution refrigerator for polarized target

    International Nuclear Information System (INIS)

    Isagawa, S.; Ishimoto, S.; Masaike, A.; Morimoto, K.

    1978-01-01

    A horizontal dilution refrigerator was constructed with a view to the spin frozen target and the deuteron polarized target. High cooling power at high temperature such as 3.7 mW at 400 mK serves for overcoming a heat load of microwave to polarize the nuclear spins in the target material. The cooling power at 50 mK was 50 μW, which is sufficient to hold the high nuclear polarization for long time. The lowest temperature reached was 26 mK. The refrigerator has rather simple heat exchangers, a long stainless steel double tube heat exchanger and two coaxial type heat exchangers with sintered copper. The mixing chamber is made of polytetrafluoroethylene (TFE) and demountable so that the target material can be easily put into it. (Auth.)

  6. Cost effectiveness of dilute chemical decontamination

    International Nuclear Information System (INIS)

    Le Surf, J.E.; Weyman, G.D.

    1983-01-01

    The origin and basic principles of the dilute chemical decontamination (DCD) concept are described and illustrated by reference to the CAN-DECON process. The estimated dose savings from the actual application of the process at several reactors are presented and discussed. Two methods of performing a cost/benefit appraisal are described and discussed. This methodology requires more study by the nuclear industry, including collection by station staff of relevant data on which future cost/benefit appraisals may be based. Finally, three illustrative cases are examinated to show the breakeven point and potential savings achievable by DCD with different initial radiation fields and different amounts of work to be done. The overall conclusion is that there are many situations in which DCD is desirable to reduce radiation exposure of workers, to save costs to the station, and to ease the performance of maintenance and repair work on reactor systems

  7. Heat pulses in dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Husson, L.P.J.

    1983-01-01

    The propagation of heat pulses in dilute 3 He- 4 He mixtures under pressure along a tube, which is long compared to its diameter, is discussed. At high temperatures, where the excitations are in local equilibrium with one another, the propagation of heat pulses in the liquid is determined by the phenomenon of second sound, which is essentially a density wave in the excitation gas. The velocity and attenuation of second sound can be determined from the shape of the transmitted pulse. Measurements on the scattering and absorption of phonons are presented, together with a detailed description of the experimental technique and the electronic equipment. Measurements on the velocity and absorption of second sound are presented. From the results for the velocity of second sound in pure 4 He, values of the phonon and roton parameters are deduced. The velocity data in the mixtures have been used to calculate values of the effective mass of 3 He in superfluid 4 He. The results of these calculations have been compared with values of the effective mass obtained by other authors. The coefficient of second-sound absorption in pure 4 He is computed from theory, making use of the phonon and roton parameters calculated from the second-sound velocity data in pure 4 He. The experimental results on the scattering and absorption of phonons have been analysed. The empirical expressions for the scattering and absorption rates obtained from the diffusive phonon signals were compared with the results of the Baym-Ebner theory, and have also been used to calculate the coefficient of thermal conductivity in dilute 3 He- 4 He mixtures. (Auth.)

  8. Asymptotic Distribution of Eigenvalues of Weakly Dilute Wishart Matrices

    Energy Technology Data Exchange (ETDEWEB)

    Khorunzhy, A. [Institute for Low Temperature Physics (Ukraine)], E-mail: khorunjy@ilt.kharkov.ua; Rodgers, G. J. [Brunel University, Uxbridge, Department of Mathematics and Statistics (United Kingdom)], E-mail: g.j.rodgers@brunel.ac.uk

    2000-03-15

    We study the eigenvalue distribution of large random matrices that are randomly diluted. We consider two random matrix ensembles that in the pure (nondilute) case have a limiting eigenvalue distribution with a singular component at the origin. These include the Wishart random matrix ensemble and Gaussian random matrices with correlated entries. Our results show that the singularity in the eigenvalue distribution is rather unstable under dilution and that even weak dilution destroys it.

  9. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  10. Dilute acid/metal salt hydrolysis of lignocellulosics

    Science.gov (United States)

    Nguyen, Quang A.; Tucker, Melvin P.

    2002-01-01

    A modified dilute acid method of hydrolyzing the cellulose and hemicellulose in lignocellulosic material under conditions to obtain higher overall fermentable sugar yields than is obtainable using dilute acid alone, comprising: impregnating a lignocellulosic feedstock with a mixture of an amount of aqueous solution of a dilute acid catalyst and a metal salt catalyst sufficient to provide higher overall fermentable sugar yields than is obtainable when hydrolyzing with dilute acid alone; loading the impregnated lignocellulosic feedstock into a reactor and heating for a sufficient period of time to hydrolyze substantially all of the hemicellulose and greater than 45% of the cellulose to water soluble sugars; and recovering the water soluble sugars.

  11. Mechanisms of urine concentration and dilution (1961); Les mecanismes de concentration et de dilution de l'urine (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Morel, F.; Guinnebault, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [French] Cette revue de question est consacree l'analyse d'un probleme de physiologie renale qui, au cours des dernieres annees, a subi un developpement et un renouveau remarquables. Sont successivement exposes: a) les donnees fournies par les mesures de clearance de l'eau libre et leur interpretation; b) les donnees fournies par la morphologie des nephrons et l'anatomie comparee du rein; c) les donnees concernant l'existence d'un gradient osmotique intrarenal; d) le principe de multiplication de concentration par contrecourant; e) la theorie actuelle de concentration de l'urine par contre-courant, et f) le controle physiologique des mecanismes de dilution et de concentration de l'urine. Les avantages de la theorie moderne et les obscurites qui subsistent sont enfin discutes. (auteurs)

  12. Mechanisms of urine concentration and dilution (1961); Les mecanismes de concentration et de dilution de l'urine (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Morel, F; Guinnebault, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [French] Cette revue de question est consacree l'analyse d'un probleme de physiologie renale qui, au cours des dernieres annees, a subi un developpement et un renouveau remarquables. Sont successivement exposes: a) les donnees fournies par les mesures de clearance de l'eau libre et leur interpretation; b) les donnees fournies par la morphologie des nephrons et l'anatomie comparee du rein; c) les donnees concernant l'existence d'un gradient osmotique intrarenal; d) le principe de multiplication de concentration par contrecourant; e) la theorie actuelle de concentration de l'urine par contre-courant, et f) le controle physiologique des mecanismes de dilution et de concentration de l'urine. Les avantages de la theorie moderne et les obscurites qui subsistent sont enfin discutes. (auteurs)

  13. Efficient removal of UDMH from dilute nitride MOCVD exhaust streams

    Science.gov (United States)

    Pahle, Jörg; Czerniak, Mike; Seeley, Andy; Baker, Derek

    2004-12-01

    Unsymmetrical dimethyl hydrazine (UDMH) (CH 3) 2N 2H 2 is often used in the deposition of dilute nitride semiconductors because it provides a source of nitrogen with a low thermal decomposition temperature (Temperature-dependent carrier lifetime in GaNAs using resonant-coupled photoconductive decay, NCPV Program Review Meeting, Lakewood, Colorado, 14-17 October, 2001). The problems with using this material, however, are its significant toxicity (0.01 ppm compared to ammonia's 25 ppm) and also the fact that it blocks the action of conventional dosed wet scrubbers sometimes used on nitride applications, resulting in diminished efficiency in removing arsine (the source of arsenic), and arsine being similarly toxic (TLV of 0.05 ppm). Efficient removal of UDMH, AsH 3 and hydrogen (which, though not toxic poses a potential safety hazard) by means of a combined thermal oxidation reaction and wet scrubber in series is described at input gas flow rates exceeding those typically encountered in practice. The detection technique employed was Fourier transform infra red spectroscopy (FTIR), and the calibration and resolution techniques will be described. For input UDMH flows of up to 445 sccm (i.e. 1.85×10 -2 mol/min), destructive reaction efficiencies (DREs) of >99.9% were demonstrated, corresponding to the background detection resolution of 0.4 ppm.

  14. Dilute Surfactant Methods for Carbonate Formations

    Energy Technology Data Exchange (ETDEWEB)

    Kishore K. Mohanty

    2006-02-01

    There are many fractured carbonate reservoirs in US (and the world) with light oil. Waterflooding is effective in fractured reservoirs, if the formation is water-wet. Many fractured carbonate reservoirs, however, are mixed-wet and recoveries with conventional methods are low (less than 10%). The process of using dilute anionic surfactants in alkaline solutions has been investigated in this work for oil recovery from fractured oil-wet carbonate reservoirs both experimentally and numerically. This process is a surfactant-aided gravity drainage where surfactant diffuses into the matrix, lowers IFT and contact angle, which decrease capillary pressure and increase oil relative permeability enabling gravity to drain the oil up. Anionic surfactants have been identified which at dilute concentration of 0.05 wt% and optimal salinity can lower the interfacial tension and change the wettability of the calcite surface to intermediate/water-wet condition as well or better than the cationic surfactant DTAB with a West Texas crude oil. The force of adhesion in AFM of oil-wet regions changes after anionic surfactant treatment to values similar to those of water-wet regions. The AFM topography images showed that the oil-wetting material was removed from the surface by the anionic surfactant treatment. Adsorption studies indicate that the extent of adsorption for anionic surfactants on calcite minerals decreases with increase in pH and with decrease in salinity. Surfactant adsorption can be minimized in the presence of Na{sub 2}CO{sub 3}. Laboratory-scale surfactant brine imbibition experiments give high oil recovery (20-42% OOIP in 50 days; up to 60% in 200 days) for initially oil-wet cores through wettability alteration and IFT reduction. Small (<10%) initial gas saturation does not affect significantly the rate of oil recovery in the imbibition process, but larger gas saturation decreases the oil recovery rate. As the core permeability decreases, the rate of oil recovery reduces

  15. Aluminium. II - A review of deformation properties of high purity aluminium and dilute aluminium alloys.

    Science.gov (United States)

    Reed, R. P.

    1972-01-01

    The elastic and plastic deformation behavior of high-purity aluminum and of dilute aluminum alloys is reviewed. Reliable property data, including elastic moduli, elastic coefficients, tensile, creep, fatigue, hardness, and impact are presented. Single crystal tensile results are discussed. Rather comprehensive reference lists, containing publications of the past 20 years, are included for each of the above categories. Defect structures and mechanisms responsible for mechanical behavior are presented. Strengthening techniques (alloys, cold work, irradiation, quenching, composites) and recovery are briefly reviewed.

  16. In-gel multiple displacement amplification of long DNA fragments diluted to the single molecule level.

    Science.gov (United States)

    Michikawa, Yuichi; Sugahara, Keisuke; Suga, Tomo; Ohtsuka, Yoshimi; Ishikawa, Kenichi; Ishikawa, Atsuko; Shiomi, Naoko; Shiomi, Tadahiro; Iwakawa, Mayumi; Imai, Takashi

    2008-12-15

    The isolation and multiple genotyping of long individual DNA fragments are needed to obtain haplotype information for diploid organisms. Limiting dilution of sample DNA followed by multiple displacement amplification is a useful technique but is restricted to short (reaction (PCR)-ready form. The haplotypes of seven SNPs spanning 240 kb of the DNA surrounding the human ATM gene region on chromosome 11 were determined for 10 individuals, demonstrating the feasibility of this new method.

  17. The bond diluted spin-1 Blume-Emery-Griffiths model in a transverse field

    International Nuclear Information System (INIS)

    Ez Zahraouy, H.

    1993-09-01

    The effect of Bond-dilution on the magnetic properties of a quantum transverse spin-1 Blume-Emery-Griffiths model is investigated within an expansion technique for cluster identities of a spin-1 localized spin system. The longitudinal and transverse magnetizations and quadrupolar moments are studied for several values of the bond concentration. A general formula, applicable to structures with arbitrary coordination number N, are given. (author). 41 refs, 6 figs

  18. Sterility and Stability of Diluted Carprofen in a Multidose Vial in the Laboratory Animal Setting.

    Science.gov (United States)

    Simonek, Gregory D; Alarcio, Gwendolyne G; Brignolo, Laurie L

    2017-05-01

    Using compounded multidose vials (cMDV) is a common practice in the laboratory animal setting, where medications often are diluted to provide appropriate doses to rodents. However, bacterial contamination of MDV has been well established in both the human and veterinary medical literature. For this study, we created 14 cMDV by diluting carprofen into sterile water (dilution, 1:10) and stored 6 cMDV each at 5 and 24 °C. The stoppers of the cMDV were not cleaned with alcohol, and all were punctured twice daily for 28 d. The sterility of the diluted carprofen was evaluated by assessing bacterial growth on days 0, 7, 14, 21, and 28 and by testing for bacterial endotoxin on days 0 and 28. We used liquid chromatography-tandem mass spectrometry to assess the stability of 2 cMDV, with each cMDV being divided into the 2 storage-temperature subsets for days 0, 7, 14, 21, and 28. Neither bacterial contamination nor endotoxin was detected, and drug stability was stable over the 28 d. We suggest that with pragmatic techniques, such as secondary containment and consistent use of new needles, the contents of cMDV can remain sterile and stable for 28 d.

  19. Extended aroma extract dilution analysis profile of Shiikuwasha (Citrus depressa Hayata pulp essential oil

    Directory of Open Access Journals (Sweden)

    Yonathan Asikin

    2018-01-01

    Full Text Available Shiikuwasha pulp is an important raw material for producing citrus essential oils. The volatile aroma composition of pulp essential oil was evaluated using gas chromatography (GC methods, and its aroma profile was assessed using GC-olfactometry with an extended aroma extract dilution analysis (AEDA technique in regard to alterations of odor strength and sensorial perception throughout serial dilution steps. The essential oil comprised a mixture of 55 aroma compounds, including monoterpene hydrocarbon, sesquiterpene hydrocarbon, alcohol, aldehyde, ester, and oxide compounds. The predominant compounds were limonene [57.36% (4462.80 mg/100 g of pulp] and γ-terpinene [25.14% (1956.21 mg/100 g of pulp]. However, linalool was identified as one of the key aroma components providing the highest flavor dilution factor in AEDA, whilst three sesquiterpene hydrocarbons (δ-elemene, germacrene B, and bicyclosesquiphellandrene and two esters (heptyl acetate and decyl acetate had superior relative flavor activities. The extended AEDA profile identified variations in assessed odor perceptions, intensity, and duration of aroma components over dilution, whereas the 12 most odor-active compounds showed comparable odor strengths.

  20. Brewing Bokashi: Strengthening Student Skills in Dilution Theory through Fermentation Analysis

    Directory of Open Access Journals (Sweden)

    Robert E. Zdor

    2016-05-01

    Full Text Available One of the basic microbiological techniques that students should master is that of using dilution theory to calculate the levels of bacteria in a fluid. This tip reports on using a rice water-milk fermentation mixture termed Bokashi as an easily implemented exercise in the basic microbiological lab to give students multiple opportunities to use dilution theory. Due to the shifts in bacterial community composition over time, a variety of microbes can be cultured using selective and nonselective media. Microscopic observation and the use of GEN III microplates to determine the collective phenotypic pattern of the mixture both give additional opportunities for students to hone their skills in bacterial analysis. Due to the decrease in the pH of the mixture over time, the notion of acid tolerance in bacteria can be explored and assessed using the microplate. By performing multiple rounds of serial dilutions and spread plating, students can practice their skill at using dilution theory several times over the course of the exercise.

  1. Dilute antiferromagnetism in magnetically doped phosphorene

    Directory of Open Access Journals (Sweden)

    Andrew Allerdt

    2017-11-01

    Full Text Available We study the competition between Kondo physics and indirect exchange on monolayer black phos-phorous using a realistic description of the band structure in combination with the density matrixrenormalization group (DMRG method. The Hamiltonian is reduced to a one-dimensional problemvia an exact canonical transformation that makes it amenable to DMRG calculations, yielding exactresults that fully incorporate the many-body physics. We find that a perturbative description of theproblem is not appropriate and cannot account for the slow decay of the correlations and the completelack of ferromagnetism. In addition, at some particular distances, the impurities decouple formingtheir own independent Kondo states. This can be predicted from the nodes of the Lindhard function.Our results indicate a possible route toward realizing dilute anti-ferromagnetism in phosphorene. Received: 19 September 2017, Accepted: 12 October 2017; Edited by: K. Hallberg; DOI: http://dx.doi.org/10.4279/PIP.090008 Cite as: A Allerdt, A E Feiguin, Papers in Physics 9, 090008 (2017

  2. Behaviour of humic-bentonite aggregates in diluted suspensions ...

    African Journals Online (AJOL)

    Formation and disaggregation of micron-size aggregates in a diluted suspension made up of HSs and bentonite (B) were studied by tracing distribution of aggregate sizes and their counts in freshly prepared and aged suspensions, and at high (10 000) and low (1.0) [HS]/[B] ratios. Diluted HSB suspensions are unstable ...

  3. Dilution in Transition Zone between Rising Plumes and Surface Plumes

    DEFF Research Database (Denmark)

    Larsen, Torben

    2004-01-01

    The papers presents some physical experiments with the dilution of sea outfall plumes with emphasize on the transition zone where the relative fast flowing vertical plume turns to a horizontal surface plume following the slow sea surface currents. The experiments show that a considerable dilution...

  4. Magnetic ordering in dilute YTb and YEr alloys

    International Nuclear Information System (INIS)

    Rainford, B.D.; Kilcoyne, S.H.; Mohammed, K.A.; Lanchester, P.C.; Stanley, H.B.; Caudron, R.

    1988-01-01

    Dilute YEr alloys (Er concentration between 3% and 10%) show the existence of sinusoidally modulated antiferromagnetism down to the lowest impurity concentrations studied. Extrapolation of the Neel temperatures for both YEr and YTb suggests a critical concentration is ≅ 0.8% Tb, Er. Ordering in such dilute alloys may result from exchange enhancement in the yttrium host

  5. Magnetic ordering in dilute YTb and YEr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Rainford, B.D.; Kilcoyne, S.H.; Mohammed, K.A.; Lanchester, P.C.; Stanley, H.B.; Caudron, R.

    1988-12-01

    Dilute YEr alloys (Er concentration between 3% and 10%) show the existence of sinusoidally modulated antiferromagnetism down to the lowest impurity concentrations studied. Extrapolation of the Neel temperatures for both YEr and YTb suggests a critical concentration is /approx equal/ 0.8% Tb, Er. Ordering in such dilute alloys may result from exchange enhancement in the yttrium host.

  6. The Melt-Dilute Treatment Technology Offgas Development Status Report

    International Nuclear Information System (INIS)

    Adams, T. M.

    1999-01-01

    The melt-dilute treatment technology is being developed to facilitate the ultimate disposition of highly enriched Al-Base DOE spent nuclear fuels in a geologic repository such as that proposed for Yucca Mountain. The melt-dilute process is a method of preparing DOE spent nuclear fuel for long term storage

  7. Near-wall molecular ordering of dilute ionic liquids

    NARCIS (Netherlands)

    Jitvisate, Monchai; Seddon, James Richard Thorley

    2017-01-01

    The interfacial behavior of ionic liquids promises tunable lubrication as well as playing an integral role in ion diffusion for electron transfer. Diluting the ionic liquids optimizes bulk parameters, such as electric conductivity, and one would expect dilution to disrupt the near-wall molecular

  8. Effect of dietary dilution of energy and nutrients during different ...

    African Journals Online (AJOL)

    A completely randomized design was conducted to evaluate the effect of dietary dilution of energy and nutrients during different growing periods on compensatory growth of Ross broilers. Four replicant pens were assigned per seven treatments. Chicks in each treatment received concentrated and diluted diets in different ...

  9. The dilute random field Ising model by finite cluster approximation

    International Nuclear Information System (INIS)

    Benyoussef, A.; Saber, M.

    1987-09-01

    Using the finite cluster approximation, phase diagrams of bond and site diluted three-dimensional simple cubic Ising models with a random field have been determined. The resulting phase diagrams have the same general features for both bond and site dilution. (author). 7 refs, 4 figs

  10. Enhancement of surface magnetism due to bulk bond dilution

    International Nuclear Information System (INIS)

    Tsallis, C.; Sarmento, E.F.; Albuquerque, E.L. de

    1985-01-01

    Within a renormalization group scheme, the phase diagram of a semi-infinite simple cubic Ising ferromagnet is discussed, with arbitrary surface and bulk coupling constants, and including possible dilution of the bulk bonds. It is obtained that dilution makes easier the appearance of surface magnetism in the absence of bulk magnetism. (Author) [pt

  11. Dynamic dilution exponent in monodisperse entangled polymer solutions

    DEFF Research Database (Denmark)

    Shahid, T.; Huang, Qian; Oosterlinck, F.

    2017-01-01

    of concentration but also depends on the molar mass of the chains. While the proposed approach successfully explains the viscoelastic properties of a large number of semi-dilute solutions of polymers in their own oligomers, important discrepancies are found for semi-dilute entangled polymers in small-molecule......We study and model the linear viscoelastic properties of several entangled semi-dilute and concentrated solutions of linear chains of different molar masses and at different concentrations dissolved in their oligomers. We discuss the dilution effect of the oligomers on the entangled long chains....... In particular, we investigate the influence of both concentration and molar mass on the value of the effective dynamic dilution exponent determined from the level of the storage plateau at low and intermediate frequencies. We show that the experimental results can be quantitatively explained by considering...

  12. The dilution effect on the extinction of wall diffusion flame

    Directory of Open Access Journals (Sweden)

    Ghiti Nadjib

    2014-12-01

    Full Text Available The dynamic process of the interaction between a turbulent jet diffusion methane flame and a lateral wall was experimentally studied. The evolution of the flame temperature field with the Nitrogen dilution of the methane jet flame was examined. The interaction between the diffusion flame and the lateral wall was investigated for different distance between the wall and the central axes of the jet flame. The dilution is found to play the central role in the flame extinction process. The flame response as the lateral wall approaches from infinity and the increasing of the dilution rate make the flame extinction more rapid than the flame without dilution, when the nitrogen dilution rate increase the flame temperature decrease.

  13. Dilute Oxygen Combustion Phase I Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, H.M.; Riley, M.F.; Kobayashi, H.

    1997-10-31

    A novel burner, in which fuel (natural gas) and oxidant (oxygen or air) are separately injected into a furnace, shows promise for achieving very low nitrogen oxide(s) (NOx) emissions for commercial furnace applications. The dilute oxygen combustion (DOC) burner achieves very low NOx through in-furnace dilution of the oxidant stream prior to combustion, resulting in low flame temperatures, thus inhibiting thermal NOx production. The results of a fundamental and applied research effort on the development of the DOC burner are presented. In addition, the results of a market survey detailing the potential commercial impact of the DOC system are disclosed. The fundamental aspects of the burner development project involved examining the flame characteristics of a natural gas turbulent jet in a high-temperature (~1366 K) oxidant (7-27% O2 vol. wet). Specifically, the mass entrainment rate, the flame lift-off height, the velocity field and major species field of the jet were evaluated as a function of surrounding-gas temperature and composition. The measured entrainment rate of the fuel jet decreased with increasing oxygen content in the surrounding high-temperature oxidant, and was well represented by the d+ scaling correlation found in the literature. The measured flame lift-off height decreased with increasing oxygen content and increasing temperature of the surrounding gas. An increase in surrounding-gas oxygen content and/or temperature inhibited the velocity decay within the jet periphery as a function of axial distance as compared to isothermal turbulent jets. However, the velocity measurements were only broadly represented by the d+ scaling correlation. Several DOC burner configurations were tested in a laboratory-scale furnace at a nominal firing rate of 185 kW (~0.63 MMBtu/h). The flue gas composition was recorded as a function of furnace nitrogen content, furnace temperature, burner geometric arrangement, firing rate, and fuel injection velocity. NOx emissions

  14. Dilute oxygen combustion. Phase I report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    A novel burner, in which fuel (natural gas) and oxidant (oxygen or air) are separately injected into a furnace, shows promise for achieving very low nitrogen oxide(s) (NO{sub x}) emissions for commercial furnace applications. The dilute oxygen combustion (DOC) burner achieves very low NO{sub x} through in-furnace dilution of the oxidant stream prior to combustion, resulting in low flame temperatures, thus inhibiting thermal NO{sub x} production. The results of a fundamental and applied research effort on the development of the DOC burner are presented. In addition, the results of a market survey detailing the potential commercial impact of the DOC system are disclosed. The fundamental aspects of the burner development project involved examining the flame characteristics of a natural gas turbulent jet in a high-temperature ({approximately}1366 K) oxidant (7-27% O{sub 2} vol. wet). Specifically, the mass entrainment rate, the flame lift-off height, the velocity field and major species field of the jet were evaluated as a function of surrounding-gas temperature and composition. The measured entrainment rate of the fuel jet decreased with increasing oxygen content in the surrounding high-temperature oxidant, and was well represented by the d{sup +} scaling correlation found in the literature. The measured flame lift-off height decreased with increasing oxygen content and increasing temperature of the surrounding gas. An increase in surrounding-gas oxygen content and/or temperature inhibited the velocity decay within the jet periphery as a function of axial distance as compared to isothermal turbulent jets. However, the velocity measurements were only broadly represented by the d{sup +} scaling correlation. Several DOC burner configurations were tested in a laboratory-scale furnace at a nominal firing rate of 185 kW ({approximately}0.63 MMBtu/h). The flue gas composition was recorded as a function of furnace nitrogen content, furnace temperature, burner geometric

  15. Role reductants in dilute chemical decontamination formulations

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, S. [Univ. of New Brunswick (Canada). Dept. of Chemical Engineering; Srinivasan, M.P.; Narasimhan, S.V. [Bhabha Atomic Research Centre (BARC), Trombay, Mumbai (India). Water and Steam Chemistry Lab.; Raghavan, P.S. [Madras Christian Coll., Chennai (India); Gopalan, R. [Madras Christian Coll., Chennai (India). Dept. of Chemistry

    2004-10-01

    Iron(III) oxides are the major corrosion products formed in boiling water reactors. The iron(III) oxides are of two types, namely hematite ({alpha}-Fe{sub 2}O{sub 3}) and maghemite ({gamma}-Fe{sub 2}O{sub 3}). The dissolution of these oxides is in no way simple because of the labile nature of the Fe(III)-O bond towards the chelants. The leaching of metal ions is partially controlled by reductive dissolution. In order to understand the role of the reductant, it is essential to study the dissolution behaviour of a system like Fe{sub 2}O{sub 3}, which does not contain any Fe{sup 2+} in the crystal lattice. The present study was carried out with {gamma}-Fe{sub 2}O{sub 3} and dilute chemical decontamination (DCD) formulations containing ascorbic acid and citric acid with the addition of Fe(II)-L as a reductant. The chelants used for the dissolution process were nitrilotriacetic acid, 2,6-pyridinedicorboxylic acid and ethylenediaminetetraacetic acid. The {gamma}-Fe{sub 2}O{sub 3} was chosen since the earlier studies revealed that the dissolution kinetics of {alpha}-Fe{sub 2}O{sub 3} is slow and it is difficult to dissolve even by strong complexing agents, whereas {gamma}-Fe{sub 2}O{sub 3} dissolution is comparatively easier. This is due to the structural difference between these two oxides. The studies also revealed that the dissolution was partly influenced by the nature of the chelating agents but mainly controlled by the power of the reductants used in the formulation. The dissolution behaviour of {gamma}-Fe{sub 2}O{sub 3} under various experimental conditions is discussed and compared with that of magnetite in order to arrive at a suitable mechanism for the dissolution of iron oxides and emphasize the role of reductants in DCD formulations. (orig.)

  16. Ionic liquids behave as dilute electrolyte solutions

    Science.gov (United States)

    Gebbie, Matthew A.; Valtiner, Markus; Banquy, Xavier; Fox, Eric T.; Henderson, Wesley A.; Israelachvili, Jacob N.

    2013-01-01

    We combine direct surface force measurements with thermodynamic arguments to demonstrate that pure ionic liquids are expected to behave as dilute weak electrolyte solutions, with typical effective dissociated ion concentrations of less than 0.1% at room temperature. We performed equilibrium force–distance measurements across the common ionic liquid 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C4mim][NTf2]) using a surface forces apparatus with in situ electrochemical control and quantitatively modeled these measurements using the van der Waals and electrostatic double-layer forces of the Derjaguin–Landau–Verwey–Overbeek theory with an additive repulsive steric (entropic) ion–surface binding force. Our results indicate that ionic liquids screen charged surfaces through the formation of both bound (Stern) and diffuse electric double layers, where the diffuse double layer is comprised of effectively dissociated ionic liquid ions. Additionally, we used the energetics of thermally dissociating ions in a dielectric medium to quantitatively predict the equilibrium for the effective dissociation reaction of [C4mim][NTf2] ions, in excellent agreement with the measured Debye length. Our results clearly demonstrate that, outside of the bound double layer, most of the ions in [C4mim][NTf2] are not effectively dissociated and thus do not contribute to electrostatic screening. We also provide a general, molecular-scale framework for designing ionic liquids with significantly increased dissociated charge densities via judiciously balancing ion pair interactions with bulk dielectric properties. Our results clear up several inconsistencies that have hampered scientific progress in this important area and guide the rational design of unique, high–free-ion density ionic liquids and ionic liquid blends. PMID:23716690

  17. Disposal of Low-Activity Liquid Effluents by Dilution

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Candillon, C. [Atomic Energy Commission, Saclay (France)

    1960-07-01

    Nuclear centres are frequently faced with problems of disposal of sizeable quantities of low-activity liquid effluents. Under present conditions the most practicable solution seems to be to discharge them into a natural or artificial water system, so as to dilute them as much as possible and thus reduce their radioactive isotope content below the public health levels. This technique is employed by all nuclear centres in France, which use the following convenient outlets: Saclay: the artificial ponds made by Louis XIV to feed the great Versailles fountains; Fontenay-aux-Roses: the Paris sewer system; Grenoble: the river Isere; Marcoule: the river Rhone. Until 1957 the amount of waste was negligible. It is still very slight at the first three centres, only a few dozen millicuries a month. At Marcoule the activity of the effluents is somewhat greater, but the Rhone's rate of flow ensures a very low final content of radioactive elements. The increasing discharge of wastes into river systems calls for a close watch on changes in radioactivity in the environment (i.e. in air, water and soil), and especially on areas in which radioactive isotopes may accumulate. We have therefore made laboratory studies of the mechanics of radioactivity concentration, in order to improve our sampling methods and ascertain the movement of wastes.

  18. Process for recovery and purification of lithium from dilute sources

    International Nuclear Information System (INIS)

    Kunugita, Eiichi; Kim, Jong-Hwa; Komasawa, Isao

    1990-01-01

    A process was studied for recovery and purification of lithium from hot spring water and leachate of coal fly ash in which lithium is present at very low concentration in a mixture of high concentration of less desirable species such as alkali metals, alkaline earth metals and others. Lithium is, as a first step, adsorbed selectively by an ion-sieve type adsorbent, λ-MnO 2 , which can effect separation by adsorbing lithium alone in its intraparticle spaces while adsorbing most metals on its surface. Stagewise elutions are performed, employing two elutrients: NH 4 NO 3 and then HNO 3 solution. The concentration ratio of lithium and sodium is 1/70∼1/120 in the original feed stream, and this is upgraded to 300/1 in the pregnant elutrient. Some impurities in the pregnant elutrient is removed by a solvent extraction technique, employing a mixed extractant of a β-diketone (LIX51) and tri-n-octyl-phosphine oxide in kerosene. A lithium solution with an undetectable amount of impurities is obtained by single extraction followed by single scrubbing with dilute hydrochloric acid of carefully controlled concentration. (author)

  19. Use of diluted urine for cultivation of Chlorella vulgaris.

    Science.gov (United States)

    Jaatinen, Sanna; Lakaniemi, Aino-Maija; Rintala, Jukka

    2016-01-01

    Our aim was to study the biomass growth of microalga Chlorella vulgaris using diluted human urine as a sole nutrient source. Batch cultivations (21 days) were conducted in five different urine dilutions (1:25-1:300), in 1:100-diluted urine as such and with added trace elements, and as a reference, in artificial growth medium. The highest biomass density was obtained in 1:100-diluted urine with and without additional trace elements (0.73 and 0.60 g L(-1), respectively). Similar biomass growth trends and densities were obtained with 1:25- and 1:300-diluted urine (0.52 vs. 0.48 gVSS L(-1)) indicating that urine at dilution 1:25 can be used to cultivate microalgal based biomass. Interestingly, even 1:300-diluted urine contained sufficiently nutrients and trace elements to support biomass growth. Biomass production was similar despite pH-variation from < 5 to 9 in different incubations indicating robustness of the biomass growth. Ammonium formation did not inhibit overall biomass growth. At the beginning of cultivation, the majority of the biomass consisted of living algal cells, while towards the end, their share decreased and the estimated share of bacteria and cell debris increased.

  20. Influence of extragent dilution upon light rare earths separation

    International Nuclear Information System (INIS)

    Korpusova, R.D.; Smirnova, N.N.

    1978-01-01

    The effect of diluting the extragent on separation of REE in the presence of 6 g-equiv. of LiNO 3 has been studied. For experiments use was made of TBP diluted with kerosene or butylbenzene (40,50,70 vol.%). The separation coefficients have been determined under conditions of saturation. The content of trace amounts of the components has been determined by the weight method; the content of macroimpurities - by the radiometric method. It has been established that the coefficient of Ce-La, Pr-La separation is not affected by the dilution of the extragent. The only exception is the Pr 142 -La pair; in the presence of trace amounts of better extracted element and two-fold dilution the separation coefficient increases almost by 150%. For the Pr-Ce pair the effect of dilution is better noticeable in that case when more extracted element is present in trace amounts. However, a comparison of the effect of dilution on separation coefficients of all REE pairs under study has shown that this effect is the strongest for the samarium-neodymium pair. The data obtained allow an assumption to be made that kerosene, as a diluent, affects the steric factor and coordination. Therefore, upon dilution the coefficient of the samarium-neodymium pair separation is affected most of all

  1. Dilution thermodynamics of the biologically relevant cation mixtures

    International Nuclear Information System (INIS)

    Kaczyński, Marek; Borowik, Tomasz; Przybyło, Magda; Langner, Marek

    2014-01-01

    Graphical abstract: - Highlights: • Dilution energetics of Ca 2+ can be altered by the aqueous phase ionic composition. • Dissipated heat upon Ca 2+ dilution is drastically reduced in the K + presence. • Reduction of the enthalpy change upon Ca 2+ dilution is K + concentration dependent. • The cooperativity of Ca 2+ hydration might be of great biological relevance providing a thermodynamic argument for the specific ionic composition of the intracellular environment. - Abstract: The ionic composition of intracellular space is rigorously controlled by a variety of processes consuming large quantities of energy. Since the energetic efficiency is an important evolutional criterion, therefore the ion fluxes within the cell should be optimized with respect to the accompanying energy consumption. In the paper we present the experimental evidence that the dilution enthalpies of the biologically relevant ions; i.e. calcium and magnesium depend on the presence of monovalent cations; i.e. sodium and potassium. The heat flow generated during the dilution of ionic mixtures was measured with the isothermal titration calorimetry. When calcium was diluted together with potassium the dilution enthalpy was drastically reduced as the function of the potassium concentration present in the solution. No such effect was observed when the potassium ions were substituted with sodium ones. When the dilution of magnesium was investigated the dependence of the dilution enthalpy on the accompanying monovalent cation was much weaker. In order to interpret experimental evidences the ionic cluster formation is postulated. The specific organization of such cluster should depend on ions charges, sizes and organization of the hydration layers

  2. Specific heat in diluted magnetic semiconductor quantum ring

    Science.gov (United States)

    Babanlı, A. M.; Ibragimov, B. G.

    2017-11-01

    In the present paper, we have calculated the specific heat and magnetization of a quantum ring of a diluted magnetic semiconductor (DMS) material in the presence of magnetic field. We take into account the effect of Rashba spin-orbital interaction, the exchange interaction and the Zeeman term on the specific heat. We have calculated the energy spectrum of the electrons in diluted magnetic semiconductor quantum ring. Moreover we have calculated the specific heat dependency on the magnetic field and Mn concentration at finite temperature of a diluted magnetic semiconductor quantum ring.

  3. On the Wigner law in dilute random matrices

    Science.gov (United States)

    Khorunzhy, A.; Rodgers, G. J.

    1998-12-01

    We consider ensembles of N × N symmetric matrices whose entries are weakly dependent random variables. We show that random dilution can change the limiting eigenvalue distribution of such matrices. We prove that under general and natural conditions the normalised eigenvalue counting function coincides with the semicircle (Wigner) distribution in the limit N → ∞. This can be explained by the observation that dilution (or more generally, random modulation) eliminates the weak dependence (or correlations) between random matrix entries. It also supports our earlier conjecture that the Wigner distribution is stable to random dilution and modulation.

  4. Dilute Oxygen Combustion Phase IV Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Riley, M.F.

    2003-04-30

    Novel furnace designs based on Dilute Oxygen Combustion (DOC) technology were developed under subcontract by Techint Technologies, Coraopolis, PA, to fully exploit the energy and environmental capabilities of DOC technology and to provide a competitive offering for new furnace construction opportunities. Capital cost, fuel, oxygen and utility costs, NOx emissions, oxide scaling performance, and maintenance requirements were compared for five DOC-based designs and three conventional air5-fired designs using a 10-year net present value calculation. A furnace direct completely with DOC burners offers low capital cost, low fuel rate, and minimal NOx emissions. However, these benefits do not offset the cost of oxygen and a full DOC-fired furnace is projected to cost $1.30 per ton more to operate than a conventional air-fired furnace. The incremental cost of the improved NOx performance is roughly $6/lb NOx, compared with an estimated $3/lb. NOx for equ8pping a conventional furnace with selective catalytic reduction (SCCR) technology. A furnace fired with DOC burners in the heating zone and ambient temperature (cold) air-fired burners in the soak zone offers low capital cost with less oxygen consumption. However, the improvement in fuel rate is not as great as the full DOC-fired design, and the DOC-cold soak design is also projected to cost $1.30 per ton more to operate than a conventional air-fired furnace. The NOx improvement with the DOC-cold soak design is also not as great as the full DOC fired design, and the incremental cost of the improved NOx performance is nearly $9/lb NOx. These results indicate that a DOC-based furnace design will not be generally competitive with conventional technology for new furnace construction under current market conditions. Fuel prices of $7/MMBtu or oxygen prices of $23/ton are needed to make the DOC furnace economics favorable. Niche applications may exist, particularly where access to capital is limited or floor space limitations

  5. Accuracy of the tritium water dilution method for determining water flux in reindeer (Rangifer tarandus)

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, R D; White, R G; Luick, J R

    1976-06-01

    The accuracy of the tritium water dilution method in estimating water flux was evaluated in reindeer under various conditions of temperature and diet. Two non-pregnant female reindeer were restrained in metabolism stalls, within controlled-environment chambers, at temperatures of +10, -5, and -20/sup 0/C; varying amounts of a commercial pelleted ration (crude protein, 13 percent) or mixed lichens (crude protein, 3 percent) were offered, and water was provided ad libitum either as snow or in liquid form. Total body water volume and water turnover were estimated using tritiated water, and the daily outputs of feces and urine were measured for each of 12 different combinations of diet and temperature. Statistical analysis of the data showed that the tritium water dilution technique gives accurate determinations of total body water flux over a wide range of environmental and nutritional conditions.

  6. The phase diagrams and the order parameters of the diluted transverse superlattice with antiferromagnetic interface coupling

    International Nuclear Information System (INIS)

    Oubelkacem, A.; El Aouad, N.; Benaboud, A.; Saber, M.

    2004-01-01

    Using the effective field theory with a probability distribution technique that accounts for the self-spin correlation functions, the magnetic properties of the Ising superlattice consisting of two ferromagnetic materials A and B, with L a layers of diluted spins S a =((1)/(2)) and L b layers of diluted spins S b =1 in an applied transverse field Ω with antiferromagnetic interface coupling are examined. For fixed values of the reduced exchange interactions and the concentration c of magnetic atoms, the phase diagrams and the total magnetization for the superlattice are studied as a function of the transverse field and the temperature. We find a number of characteristic phenomena. In particular, the effect of the concentration c of magnetic atoms, the interlayer coupling and the transverse field on both the compensation temperature and the magnetization profiles are clarified. Some of them may be related to the experimental works of rare-earth (RE)/transition metal (TM) multilayer films

  7. Tricritical behavior in the diluted transverse spin-1 Ising model with a longitudinal crystal field

    International Nuclear Information System (INIS)

    Htoutou, K.; Oubelkacem, A.; Ainane, A.; Saber, M.

    2005-01-01

    The transverse spin-1 Ising model with a longitudinal crystal field exhibits a tricritical behavior. Within the effective field theory with a probability distribution technique that accounts for the self-spin correlations, we have studied the influence of site dilution on this behavior and have calculated the temperature-transverse field-longitudinal crystal field-concentration phase diagrams and determined, in particular, the influence of the concentration of magnetic atoms c on the tricritical behavior. We have found that the tricritical point appears for large values of the concentration c of magnetic atoms and disappears with the increase in dilution (small values of c). Results for square lattice are calculated numerically and some interesting results are obtained. In certain ranges of values of the strength of the longitudinal crystal field D/J when it becomes sufficiently negative, we found re-entrant phenomenon, which disappears with increase in the value of the strength of the transverse field

  8. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry (Spanish Edition); Introduccion a la determinacion de la composicion corporal mediante la tecnica de dilucion de deuterio con analisis de muestras de orina por espectrometria de masas de relacion isotopica

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-11-15

    The IAEA has fostered the more widespread use of a stable isotope technique to assess body composition in different population groups to address priority areas in public health nutrition in Member States. It has done this by supporting national and regional nutrition projects through its technical cooperation programme and coordinated research projects over many years. This publication was developed by an international group of experts to provide practical hands-on guidance in the use of this technique in settings where analysis of stable isotope ratios in biological samples is to be made by isotope ratio mass spectrometry. The publication is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical applications of state of the art methodologies to monitor changes in body composition can be found in IAEA Human Health Series No. 3, Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques.

  9. Transverse emittance dilution due to coupler kicks in linear accelerators

    Directory of Open Access Journals (Sweden)

    Brandon Buckley

    2007-11-01

    Full Text Available One of the main concerns in the design of low emittance linear accelerators (linacs is the preservation of beam emittance. Here we discuss one possible source of emittance dilution, the coupler kick, due to transverse electromagnetic fields in the accelerating cavities of the linac caused by the power coupler geometry. In addition to emittance growth, the coupler kick also produces orbit distortions. It is common wisdom that emittance growth from coupler kicks can be strongly reduced by using two couplers per cavity mounted opposite each other or by having the couplers of successive cavities alternate from above to below the beam pipe so as to cancel each individual kick. While this is correct, including two couplers per cavity or alternating the coupler location requires large technical changes and increased cost for superconducting cryomodules where cryogenic pipes are arranged parallel to a string of several cavities. We therefore analyze consequences of alternate coupler placements. We show here that alternating the coupler location from above to below compensates the emittance growth as well as the orbit distortions. For sufficiently large Q values, alternating the coupler location from before to after the cavity leads to a cancellation of the orbit distortion but not of the emittance growth, whereas alternating the coupler location from before and above to behind and below the cavity cancels the emittance growth but not the orbit distortion. We show that cancellations hold for sufficiently large Q values. These compensations hold even when each cavity is individually detuned, e.g., by microphonics. Another effective method for reducing coupler kicks that is studied is the optimization of the phase of the coupler kick so as to minimize the effects on emittance from each coupler. This technique is independent of the coupler geometry but relies on operating on crest. A final technique studied is symmetrization of the cavity geometry in the

  10. A theory of stable-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Pickup, J.F.; McPherson, C.K.

    1977-01-01

    In order to perform quantitative analysis using stable isotope dilution with mass spectrometry, an equation is derived which describes the relationship between the relative proportions of natural and labelled material and measured isotope ratios

  11. Paradigms in isotope dilution mass spectrometry for elemental speciation analysis

    International Nuclear Information System (INIS)

    Meija, Juris; Mester, Zoltan

    2008-01-01

    Isotope dilution mass spectrometry currently stands out as the method providing results with unchallenged precision and accuracy in elemental speciation. However, recent history of isotope dilution mass spectrometry has shown that the extent to which this primary ratio measurement method can deliver accurate results is still subject of active research. In this review, we will summarize the fundamental prerequisites behind isotope dilution mass spectrometry and discuss their practical limits of validity and effects on the accuracy of the obtained results. This review is not to be viewed as a critique of isotope dilution; rather its purpose is to highlight the lesser studied aspects that will ensure and elevate current supremacy of the results obtained from this method

  12. An overview the boron dilution issue in PWRs

    International Nuclear Information System (INIS)

    Hyvaerinen, J.

    1994-01-01

    The presentation is an overview of boron (boric acid) dilution in pressurized water reactors (PWRs). Boric acid has been widely used in PWRs as a dissolved poison, as one of the main reactivity controlling means, for a long time, from nearly but not quite from the beginning of the design, construction and operation of PWRs in the present-day sense. The specific safety issue, namely the risk of uncontrolled reactivity insertion due to inadvertent boron dilution, is discussed first, followed by a brief look on the history of boron usage in PWRs. A discussion of boron dilution phenomenology is presented next in general terms. Some particular concerns that boron dilution phenomena arouse in the minds of a regulator will also be presented before concluding with a brief look on the future of dissolved poisons. (11 refs.)

  13. A Cold Cycle Dilution Refrigerator for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The cold cycle dilution refrigerator is a continuous refrigerator capable of cooling to temperatures below 100 mK that makes use of a novel thermal magnetic pump....

  14. Influence Of Dilution Factor For Activity Measurement Of 60CO

    International Nuclear Information System (INIS)

    Hermawan-Candra; Nazaroh; Ermi-Juita

    2003-01-01

    Influence of dilution factor for activity measurement of 60 Co has been studied. The aim of this research is to determine influence between activity measurement result of 60 Co before and after diluted. Measurement were done by using ionization chamber detectors system and gamma spectrometry system with NaI(TI) detector. Discrepancy within three ionization chambers measurements were 0.2% - 2.1% and NaI(Tl) were 3.5% - 6%. (author)

  15. Attentional sets influence perceptual load effects, but not dilution effects.

    Science.gov (United States)

    Benoni, Hanna; Zivony, Alon; Tsal, Yehoshua

    2014-01-01

    Perceptual load theory [Lavie, N. (1995). Perceptual load as a necessary condition for selective attention. Journal of Experimental Psychology: Human Perception and Performance, 21, 451-468.; Lavie, N., & Tsal, Y. (1994) Perceptual load as a major determinant of the locus of selection in visual attention. Perception & Psychophysics, 56, 183-197.] proposes that interference from distractors can only be avoided in situations of high perceptual load. This theory has been supported by blocked design manipulations separating low load (when the target appears alone) and high load (when the target is embedded among neutral letters). Tsal and Benoni [(2010a). Diluting the burden of load: Perceptual load effects are simply dilution effects. Journal of Experimental Psychology: Human Perception and Performance, 36, 1645-1656.; Benoni, H., & Tsal, Y. (2010). Where have we gone wrong? Perceptual load does not affect selective attention. Vision Research, 50, 1292-1298.] have recently shown that these manipulations confound perceptual load with "dilution" (the mere presence of additional heterogeneous items in high-load situations). Theeuwes, Kramer, and Belopolsky [(2004). Attentional set interacts with perceptual load in visual search. Psychonomic Bulletin & Review, 11, 697-702.] independently questioned load theory by suggesting that attentional sets might also affect distractor interference. When high load and low load were intermixed, and participants could not prepare for the presentation that followed, both the low-load and high-load trials showed distractor interference. This result may also challenge the dilution account, which proposes a stimulus-driven mechanism. In the current study, we presented subjects with both fixed and mixed blocks, including a mix of dilution trials with low-load trials and with high-load trials. We thus separated the effect of dilution from load and tested the influence of attentional sets on each component. The results revealed that whereas

  16. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Saliva Samples by Fourier Transform Infrared Spectrometry (Spanish Edition); Introduccion a la determinacion de la composicion corporal mediante la tecnica de dilucion de deuterio con analisis de muestras de saliva por espectrometria infrarroja por transformada de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-12-15

    For many years, the IAEA has fostered the more widespread use of stable isotope techniques to assess body composition in different population groups to address priority areas in public health nutrition in Member States. The objective is to support national and regional nutrition projects through both the IAEA's technical cooperation programme and its coordinated research projects. In particular, during the last few years, the increased access to analyses of deuterium enrichment by Fourier transform infrared (FTIR) spectrometry has increased the application of this technique in Africa, Asia and Latin America. This publication was developed by an international group of experts to provide practical, hands-on guidance in the use of this technique in settings where the analysis of deuterium enrichment in saliva samples will be made by FTIR. It is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical application of state of the art methodologies to monitor changes in body composition can be found in an IAEA publication entitled Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques (IAEA Human Health Series No. 3)

  17. Effects of dissolved species on radiolysis of diluted seawater

    International Nuclear Information System (INIS)

    Hata, Kuniki; Hanawa, Satoshi; Kasahara, Shigeki; Motooka, Takafumi; Tsukada, Takashi; Muroya, Yusa; Yamashita, Shinichi; Katsumura, Yosuke

    2014-01-01

    Fukushima Daiichi Nuclear Power Plants (NPPs) experienced seawater injection into the cores and fuel pools as an emergent measure after the accident. After the accident, retained water has been continuously desalinized, and subsequently the concentration of chloride ion (Cl"-) has been kept at a lower level these days. These ions in seawater are known to affect water radiolysis, which causes the production of radiolytic products, such as hydrogen peroxide (H_2O_2), molecular hydrogen (H_2) and molecular oxygen (O_2). However, the effects of dissolved ions relating seawater on the production of the stable radiolytic products are not well understood in the diluted seawater. To understand of the production behavior in diluted seawater under radiation, radiolysis calculations were carried out. Production of H_2 is effectively suppressed by diluting by up to vol10%. The concentrations of oxidants (H_2O_2 and O_2) are also suppressed by dilution of dissolved species. The effect of oxidants on corrosion of materials is thought to be low when the seawater was diluted by less than 1 vol% by water. It is also shown that deaeration is one of the effective measure to suppress the concentrations of oxidants at a lower level for any dilution conditions. (author)

  18. Dilution Refrigeration of Multi-Ton Cold Masses

    CERN Document Server

    Wikus, P; CERN. Geneva

    2007-01-01

    Dilution refrigeration is the only means to provide continuous cooling at temperatures below 250 mK. Future experiments featuring multi-ton cold masses require a new generation of dilution refrigeration systems, capable of providing a heat sink below 10 mK at cooling powers which exceed the performance of present systems considerably. This thesis presents some advances towards dilution refrigeration of multi-ton masses in this temperature range. A new method using numerical simulation to predict the cooling power of a dilution refrigerator of a given design has been developed in the framework of this thesis project. This method does not only allow to take into account the differences between an actual and an ideal continuous heat exchanger, but also to quantify the impact of an additional heat load on an intermediate section of the dilute stream. In addition, transient behavior can be simulated. The numerical model has been experimentally verified with a dilution refrigeration system which has been designed, ...

  19. Validity of the tritiated thymidine method for estimating bacterial growth rates: measurement of isotope dilution during DNA synthesis

    International Nuclear Information System (INIS)

    Pollard, P.C.; Moriarty, D.J.W.

    1984-01-01

    The rate of tritiated thymidine incorporation into DNA was used to estimate bacterial growth rates in aquatic environments. To be accurate, the calculation of growth rates has to include a factor for the dilution of isotope before incorporation. The validity of an isotope dilution analysis to determine this factor was verified in experiments reported here with cultures of a marine bacterium growing in a chemostat. Growth rates calculated from data on chemostat dilution rates and cell density agreed well with rates calculated by tritiated thymidine incorporation into DNA and isotope dilution analysis. With sufficiently high concentrations of exogenous thymidine, de novo synthesis of deoxythymidine monophosphate was inhibited, thereby preventing the endogenous dilution of isoope. The thymidine technique was also shown to be useful for measuring growth rates of mixed suspensions of bacteria growing anaerobically. Thymidine was incorporated into the DNA of a range of marine pseudomonads that were investigated. Three species did not take up thymidine. The common marine cyanobacterium Synechococcus species did not incorporate thymidine into DNA

  20. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  1. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  2. Alternatives for optimization of the heavy oil production in onshore marginal fields in Brazil; Alternativas para otimizacao de producao de oleos pesados em campos marginais terrestres no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Arlindo Antonio de [PETROBRAS, Rio de Janeiro, RJ (Brazil); Santos, Edmilson Moutinho dos [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia. Programa Interunidades de Pos-graduacao em Energia

    2004-07-01

    The intention of this article is to present possible alternatives for optimization of the production of heavy oils in marginal onshore fields in Brazil. The use of gas micro-turbines, the application of SAGD (Steam Assisted Gravity Drainage), the use of the drilling technique for river crossing and to a proposal for a new system of the rig less workovers are approached. The focus is the search of the increment of the production, the increase of the factor of final recovery, the global reduction of the costs and the minimization of the environmental impacts. The volumes of heavy oils in Campos Basin and in national onshore areas they are significant and, therefore, techniques and procedures that optimize its production are strategic. In the Brazilian Northeast there are a series of small fields of low productivity, in general of heavy oils, some in production there are more than twenty years that need of a reduction of the cost for barrel to continue producing. A realistic and responsible posture with the use of probabilistics concepts, techniques of engineering of the reliability, adoption of 'tolerable' levels of risk (associate to the return), attendance on line of the sceneries, premises and criteria, (proposal of the methodology GERISK), are relevant factors that can propitiate not only the reduction of the cost for produced barrel as well as to take the an increase of the factor of final recovery of the field. (author)

  3. Alternatives for optimization of the heavy oil production in onshore marginal fields in Brazil; Alternativas para otimizacao de producao de oleos pesados em campos marginais terrestres no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Arlindo Antonio de [PETROBRAS, Rio de Janeiro, RJ (Brazil); Santos, Edmilson Moutinho dos [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia. Programa Interunidades de Pos-graduacao em Energia

    2004-07-01

    The intention of this article is to present possible alternatives for optimization of the production of heavy oils in marginal onshore fields in Brazil. The use of gas micro-turbines, the application of SAGD (Steam Assisted Gravity Drainage), the use of the drilling technique for river crossing and to a proposal for a new system of the rig less workovers are approached. The focus is the search of the increment of the production, the increase of the factor of final recovery, the global reduction of the costs and the minimization of the environmental impacts. The volumes of heavy oils in Campos Basin and in national onshore areas they are significant and, therefore, techniques and procedures that optimize its production are strategic. In the Brazilian Northeast there are a series of small fields of low productivity, in general of heavy oils, some in production there are more than twenty years that need of a reduction of the cost for barrel to continue producing. A realistic and responsible posture with the use of probabilistics concepts, techniques of engineering of the reliability, adoption of 'tolerable' levels of risk (associate to the return), attendance on line of the sceneries, premises and criteria, (proposal of the methodology GERISK), are relevant factors that can propitiate not only the reduction of the cost for produced barrel as well as to take the an increase of the factor of final recovery of the field. (author)

  4. Single well techniques

    International Nuclear Information System (INIS)

    Drost, W.

    1983-01-01

    The single well technique method includes measurement of parameters of groundwater flow in saturated rock. For determination of filtration velocity the dilution of radioactive tracer is measured, for direction logging the collimeter is rotated in the probe linked with the compass. The limiting factor for measurement of high filtration velocities is the occurrence of turbulent flow. The single well technique is used in civil engineering projects, water works and subsurface drainage of liquid waste from disposal sites. The radioactive tracer method for logging the vertical fluid movement in bore-holes is broadly used in groundwater survey and exploitation. (author)

  5. Dilution and Mixing in transient velocity fields: a first-order analysis

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe, P. J.; Fiori, Aldo; Bellin, Alberto

    2017-04-01

    An appealing remediation technique is in situ oxidation, which effectiveness is hampered by difficulties in obtaining good mixing of the injected oxidant with the contaminant, particularly when the contaminant plume is contained and therefore its deformation is physically constrained. Under such conditions (i.e. containment), mixing may be augmented by inducing temporal fluctuations of the velocity field. The temporal variability of the flow field may increase the deformation of the plume such that diffusive mass flux becomes more effective. A transient periodic velocity field can be obtained by an engineered sequence of injections and extractions from wells, which may serve also as a hydraulic barrier to confine the plume. Assessing the effectiveness of periodic flows to maximize solute mixing is a difficult task given the need to use a 3D setup and the large number of possible flow configurations that should be analyzed in order to identify the optimal one. This is the typical situation in which analytical solutions, though approximated, may assist modelers in screening possible alternative flow configurations such that solute dilution is maximized. To quantify dilution (i.e. a precondition that enables reactive mixing) we utilize the concept of the dilution index [1]. In this presentation, the periodic flow takes place in an aquifer with spatially variable hydraulic conductivity field which is modeled as a Stationary Spatial Random Function. We developed a novel first-order analytical solution of the dilution index under the hypothesis that the flow can be approximated as a sequence of steady state configurations with the mean velocity changing with time in intensity and direction. This is equivalent to assume that the characteristic time of the transient behavior is small compared to the period characterizing the change in time of the mean velocity. A few closed paths have been analyzed quantifying their effectiveness in enhancing dilution and thereby mixing

  6. Regression dilution bias: tools for correction methods and sample size calculation.

    Science.gov (United States)

    Berglund, Lars

    2012-08-01

    Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.

  7. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Within the framework of the Safeguards Project of the Federal Republic of Germany at the Nuclear Research Center Karlsruhe an analytical intercomparison program was carried out in cooperation with 22 laboratories of 13 countries or international organizations. The main objective was the acquisition of basic data on the errors involved in the mass spectrometric isotope dilution analysis if it is applied to the determination of uranium and plutonium in diluted active feed solutions of reprocessing plants in routine operation. The results were evaluated by statistical methods mainly in regard to the calculation of the estimates of the variances for the different error components contributing to the total error of this analytical technique. Furthermore, the performance of two new methods for sample conditioning suggested by the International Atomic Energy Agency, Vienna, and the European Institute for Transuranium Elements (EURATOM), Karlsruhe, was successfully tested. The results of some investigations on the stability of diluted high active feed solutions and on comparison analysis by X-ray fluorescence spectrometry are also included. Data on the analytical efforts (manhours) invested in this study are reported as well as general experiences made in the organization and performance of an experiment on such an extended international level. (orig.) [de

  8. Development, validation and biomedical applications of stable-isotope dilution GC-MS and GC-MS/MS techniques for circulating malondialdehyde (MDA) after pentafluorobenzyl bromide derivatization: MDA as a biomarker of oxidative stress and its relation to 15(S)-8-iso-prostaglandin F2α and nitric oxide (NO).

    Science.gov (United States)

    Tsikas, Dimitrios; Rothmann, Sabine; Schneider, Jessica Y; Suchy, Maria-Theresia; Trettin, Arne; Modun, Darko; Stuke, Nadine; Maassen, Norbert; Frölich, Jürgen C

    2016-04-15

    Malondialdehyde (MDA, CH2(CHO)2) is one of the best investigated and most frequently measured biomarkers of lipid peroxidation in biological fluids, a constituent of the so called thiobarbituric acid reactive substances (TBARS). The reaction of thiobarbituric acid with MDA and other carbonyl compounds is the basis for the batch TBARS assay, one of the most commonly and widely used assays of oxidative stress. Yet, the TBARS assay lacks specificity even if combined with HPLC separation prior to visible absorbance or fluorescence detection. In this article, we report highly specific and sensitive stable-isotope dilution GC-MS and GC-MS/MS methods for the quantitative determination of MDA in human plasma (0.1 mL). These methods utilize the acidity (pKa, 4.46) of the two methylene H protons of MDA in aqueous solution, which are as acidic as acetic acid. Endogenous MDA in native plasma and the externally added internal standard [1,3-(2)H2]-MDA (d2-MDA, CH2(CDO)2) are derivatized in aqueous acetone (400 μL) with pentafluorobenzyl (PFB) bromide (10 μL). The reaction products were identified as C(PFB)2(CHO)2 (molecular weight, 432) and C(PFB)2(CDO)2) (molecular weight, 434), respectively. After solvent extraction with toluene (1 mL) quantification is performed by selected-ion monitoring (SIM) in GC-MS and by selected-reaction monitoring (SRM) in GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode. In the SIM mode, the anions [M-PFB](-) at m/z 251 for MDA and m/z 253 for d2-MDA are detected. In the SRM mode, the mass transitions m/z 251 to m/z 175 for MDA and m/z 253 to m/z 177 for d2-MDA are monitored. The method was thoroughly validated in human plasma. Potential interfering substances including anticoagulants and commercially available monovettes commonly used for blood sampling were tested. The lowest MDA concentrations were measured in serum followed by heparinized and EDTA plasma. The GC-MS and GC-MS/MS methods were found to be specific

  9. Modeling syngas-fired gas turbine engines with two dilutants

    Science.gov (United States)

    Hawk, Mitchell E.

    2011-12-01

    Prior gas turbine engine modeling work at the University of Wyoming studied cycle performance and turbine design with air and CO2-diluted GTE cycles fired with methane and syngas fuels. Two of the cycles examined were unconventional and innovative. The work presented herein reexamines prior results and expands the modeling by including the impacts of turbine cooling and CO2 sequestration on GTE cycle performance. The simple, conventional regeneration and two alternative regeneration cycle configurations were examined. In contrast to air dilution, CO2 -diluted cycle efficiencies increased by approximately 1.0 percentage point for the three regeneration configurations examined, while the efficiency of the CO2-diluted simple cycle decreased by approximately 5.0 percentage points. For CO2-diluted cycles with a closed-exhaust recycling path, an optimum CO2-recycle pressure was determined for each configuration that was significantly lower than atmospheric pressure. Un-cooled alternative regeneration configurations with CO2 recycling achieved efficiencies near 50%, which was approximately 3.0 percentage points higher than the conventional regeneration cycle and simple cycle configurations that utilized CO2 recycling. Accounting for cooling of the first two turbine stages resulted in a 2--3 percentage point reduction in un-cooled efficiency, with air dilution corresponding to the upper extreme. Additionally, when the work required to sequester CO2 was accounted for, cooled cycle efficiency decreased by 4--6 percentage points, and was more negatively impacted when syngas fuels were used. Finally, turbine design models showed that turbine blades are shorter with CO2 dilution, resulting in fewer design restrictions.

  10. Dilution Ratios for HB Line Phase I Eductor System

    International Nuclear Information System (INIS)

    Steimke, J.L.

    2002-01-01

    HB Line Phase I product transfer includes an eductor which transfers liquid from Product Hold Tank (PHT) RT-33 or RT-34 to Tank 11.1. The eductor also dilutes the liquid from the PHT with eductant. Dilution must be reliably controlled because of criticality concerns with H Canyon Tanks. The eductor system, which contains a 1 inch Model 264 Schutte and Koerting eductor, was previously modeled [1] in 1998 and dilution ratios were calculated for different flow restrictors, eductant pressures and densities for the eductant and the contents of the PHT. The previous calculation was performed using spreadsheet software no longer supported at SRS. For the previous work dilution ratio was defined as the volume of eductant consumed divided by volume of PHT contents transferred. Since 1998 HB Line Engineering has changed the definition of dilution ratio to the total volume of liquid, eductant consumed plus the volume of PHT liquid transferred, divided by the volume of PHT liquid transferred. The 1998 base case calculation was for a restrictor diameter of 0.334 inches, an eductant supply pressure of 15 psig, full PHT, an eductant specific gravity of 1.385 and a PHT density of 1.015. The base case dilution ratio calculated in 1998 using the current definition was 3.52. After accounting for uncertainty the minimum dilution ratio decreased to 3.23. In 2001 HB Line Engineering requested that the calculation be repeated for a manganous nitrate solution eductant and also a process water eductant. The other conditions were the same as for the 1998 calculation. The objective of this report is to document the calculations and the results

  11. High-dilution on-stream isotopic tracer techniques; Emploi d'indicateurs radioactifs tres dilues pour le controle les courants; Metody primeneniya sil'no razbavlennykh v potokakh izotopnykh indikatorov; Empleo de indicadores radiactivos muy diluidos en el control de corrientes

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, W H; Findeis, A F; Vestal, M [William H . Johnston Laboratories, Inc., Baltimore, MD (United States)

    1962-01-15

    The present paper concerns large-scale tracer applications in which isotope tagging is done on a component of main flowing fluid or stream without subsequent mainline separation. Equations are derived which relate the required levels of tracer concentrations, the instrumental background, the efficiency of the detector, the required statistical reliability, the time desired for the measurements of sample and background, the stream flow rates, and the tracer nuclide. These equations are shown graphically and allow a ready selection of the tracer concentrations for specific applications. The sampling programme for large-scale tracer applications is analysed for steady state and pulse injections. In the latter case, the longitudinal mixing is treated by the concept of eddy diffusion coefficients. By estimating certain parameters, the longitudinal tracer detection range and the first arrival time are obtained as a function of distance between injection and collection. l'or high-dilution on-stream radiotracing with beta-emitters, the detectors are large low-level internal-gas-tube counters, foil-flow counters, and plastic scintillators. New anticoincidence counters are presented. The advantages of low-atomic-number shielding are emphasized. Recent developments in stable transistorized electronics for low-level counting are shown. A new amplifier and a new tunnel-diode adder circuit are described. Examples are given of several new applications of high-dilution on-stream tracers to problems of source-identification of pollutions in rivers and streams. (author) [French] Le memoire traite de l'emploi a grande echelle d'indicateurs pour le marquage isotopique des eaux d'un courant affluent qui ne se separe pas ensuite du courant principal. Les auteurs ont etabli des equations indiquant les rapports entre le taux de concentration des indicateurs, le bruit de fond du aux instruments, l'efficacite du detecteur, la qualite que l'on attend des donnees statistiques obtenues, le

  12. Optimization of the daily operation of the plants of Medio Sao Francisco; Otimizacao da operacao diaria das usinas do Medio Sao Francisco

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Jessica Pillon Torralba; Colnago, Glauber Renato; Correia, Paulo de Barros; Ohishi, Takaaki [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Mecanica. Dept. de Energia], emails: pillon@fem.unicamp.br, colnago@fem.unicamp.br, pcorreia@fem.unicamp.br, taka@densis.fee.unicamp.br

    2010-07-01

    This paper presents an optimization model for daily operation of Sao Francisco hydroelectric power plants. The study considers eight power plants - Sobradinho (USB), Luiz Gonzaga (ULG), Apolonio Sales (UAS), Paulo Afonso I, II, III, (UPA), Paulo Afonso IV (USQ) e Xingo (UXG)- belongs to Sao Francisco Hydroelectric Company (CHESF). Its objective is to maximize the power plant efficiency and to minimize the number of startup and shutdowns of generating units (GU), simultaneously. Considering those GU are equal, is determined the number of units to be dispatched and their charge. The optimal dispatch, linear and non-linear programming techniques and genetic algorithms (GA) support this article. (author)

  13. Evaluation of urban and industrial wastewater treatment plants using radioactive tracers; Otimizacao de unidades de tratamento de aguas residuais urbanas e industriais empregando-se tracadores radioativos

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Luis Eduardo Barreira

    2001-07-01

    A methodology for studies and evaluation of sewage treatment plants with radioactive tracers is presented.. Radioisotopes as {sup 82} Br ( for the liquid phase), {sup 110m} Ag and {sup 140} La, (for the solid phase) was used to evaluate sewage flow rates, mixing pattern in equalization tank and test effluent treatment units. The tracer was injected in the unit (instantaneously or in a constant rate with a pump) and NaI-scintillation detectors measured the output signal. The Fortran program TRACADORES was developed to analyze the response function of the units in form of residence times distribution curves (RTD), which represents the probability of an element of the material to interact with the unit, and calculate the mean residence time {gamma}, the central moment of this distribution function. This fundamental parameter characterizes the tank and serves as a quantitative evaluation for its performance. With the radiotracer techniques was possible to identify dead zone, channeling, internal circulation of the solid phase inside the tanks. The technique represents a guideline for redesign a imperfect unit and eliminate the problem. (author)

  14. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  15. Mobile Melt-Dilute Treatment for Russian Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Peacock, H.

    2002-01-01

    Treatment of spent Russian fuel using a Melt-Dilute (MD) process is proposed to consolidate fuel assemblies into a form that is proliferation resistant and provides critically safety under storage and disposal configurations. Russian fuel elements contain a variety of fuel meat and cladding materials. The Melt-Dilute treatment process was initially developed for aluminum-based fuels so additional development is needed for several cladding and fuel meat combinations in the Russian fuel inventory (e.g. zirconium-clad, uranium-zirconium alloy fuel). A Mobile Melt-Dilute facility (MMD) is being proposed for treatment of spent fuels at reactor site storage locations in Russia; thereby, avoiding the costs of building separate treatment facilities at each site and avoiding shipment of enriched fuel assemblies over the road. The MMD facility concept is based on laboratory tests conducted at the Savannah River Technology Center (SRTC), and modular pilot-scale facilities constructed at the Savannah River Site for treatment of US spent fuel. SRTC laboratory tests have shown the feasibility of operating a Melt-Dilute treatment process with either a closed system or a filtered off-gas system. The proposed Mobile Melt-Dilute process is presented in this paper

  16. Quantifying the dilution effect for models in ecological epidemiology.

    Science.gov (United States)

    Roberts, M G; Heesterbeek, J A P

    2018-03-01

    The dilution effect , where an increase in biodiversity results in a reduction in the prevalence of an infectious disease, has been the subject of speculation and controversy. Conversely, an amplification effect occurs when increased biodiversity is related to an increase in prevalence. We explore the conditions under which these effects arise, using multi species compartmental models that integrate ecological and epidemiological interactions. We introduce three potential metrics for quantifying dilution and amplification, one based on infection prevalence in a focal host species, one based on the size of the infected subpopulation of that species and one based on the basic reproduction number. We introduce our approach in the simplest epidemiological setting with two species, and show that the existence and strength of a dilution effect is influenced strongly by the choices made to describe the system and the metric used to gauge the effect. We show that our method can be generalized to any number of species and to more complicated ecological and epidemiological dynamics. Our method allows a rigorous analysis of ecological systems where dilution effects have been postulated, and contributes to future progress in understanding the phenomenon of dilution in the context of infectious disease dynamics and infection risk. © 2018 The Author(s).

  17. A Study on the Stability of Diluted Bee Venom Solution

    Directory of Open Access Journals (Sweden)

    Mi-Suk Kang

    2003-06-01

    Full Text Available Objective : The purpose of this study was to investigate the stability of bee venom according to the keeping method and period. Method : The author observed microbial contamination of bee venom in nutrient agar, broth, YPD agar and YPD media and antibacterial activity for S. aureus, E. coli manufactured 12, 6 and 3 months ago as the two type of room temperature and 4℃ cold storage. Result : 1. 1:3,000 and 1:4,000 diluted bee venom solution did not show microbial contamination both room temperature and cold storage within twelve months. 2. There was antibacterial activity of diluted bee venom for S. aureus in cold storage within twelve months and there was no antibacterial activity of diluted bee venom for S. aureus in twelve months, room temperature storage. 3. We could not observe the zone of inhibition around paper disc of all for E.coli. in 1:3,000, 1:30,000 and 1:3,000,000 diluted bee venom solution, respectively. According to results, we expect that diluted bee venom solution is stable both cold and room temperature storage within twelve months.

  18. Initial magnetic susceptibility of the diluted magnetopolymer elastic composites

    International Nuclear Information System (INIS)

    Borin, D.Yu.; Odenbach, S.

    2017-01-01

    In this work diluted magnetopolymer elastic composites based on magnetic microparticles are experimentally studied. Considered samples have varied concentration of the magnetic powder and different structural anisotropy. Experimental data on magnetic properties are accomplished by microstructural observations performed using X-Ray tomography. Influence of the particles amount and structuring effects on the initial magnetic susceptibility of the composites as well as the applicability of the Maxwell-Garnett approximation, which is widely used in considerations of magnetopolymer elastic composites, are evaluated. It is demonstrated that the approximation works well for diluted samples containing randomly distributed magnetic particles and for the diluted samples with chain-like structures oriented perpendicular to an externally applied field, while it fails to predict the susceptibility of the samples with structures oriented parallel to the field. Moreover, it is shown, that variation of the chains morphology does not significantly change the composite initial magnetic susceptibility. - Highlights: • The Maxwell-Garnet prediction works well for the diluted isotropic composites. • The Maxwell-Garnet prediction can be used for composites with structures oriented perpendicular to an applied field. • Chains oriented parallel to an applied field significantly increase the composite initial magnetic susceptibility. • The number and thickness of chains is not of the highest importance for the diluted composites. • The crucial reason of the observed effect is expected to be the demagnetisation factor of the chains.

  19. A probabilistic analysis of rapid boron dilution scenarios

    International Nuclear Information System (INIS)

    Kohut, P.; Diamond, D.J.

    1993-01-01

    A probabilistic and deterministic analysis of a rapid boron dilution scenario related to reactor restart was performed. The event is initiated by a loss of off-site power during the startup dilution process. The automatic restart of the charging pump in such cases may lead to the accumulation of a diluted slug of water in the lower plenum. The restart of the reactor coolant pumps may send the diluted slug through the core, adding sufficient reactivity to overcome the shutdown margin and cause a power excursion. The concern is that the power excursion is sufficient in certain circumstances to cause fuel damage. The estimated core damage frequency based on the scoping analysis is 1.0--3.0E-05/yr for the plants analyzed. These are relatively significant values when compared to desirable goals. The analysis contained assumptions related to plant specific design characteristics which may lead to non-conservative estimates. The most important conservative assumptions were that mixing of the injected diluted water is insignificant and that fuel damage occurs when the slug passes through the core

  20. Optimization of cyclones geometry for sand pre-separation of petroleum production; Otimizacao de ciclone para a pre-separacao de areia na producao de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Aline T. de [Chemtech, Rio de Janeiro, RJ (Brazil); Medronho, Ricardo A. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola de Quimica

    2008-07-01

    Sand production in petroleum holes is a critical problem in separation plants in petroleum platforms. Sand may cause severe erosion in valves and lines and its accumulation in main process devices may force stopping the process for cleaning. This may be responsible for huge production loses. In this work, the geometrical proportions of a cyclone with high efficiency for sand-gas separation. For that, experimental design was employed to select the geometries to be studied. The separation efficiency was obtained by Computational Fluid Dynamics technique, with the commercial software CFX, version 11.0. This tool numerically solves the conservation equations, which permits estimating fluid and particles trajectory inside the equipment. Then, it was possible to obtain a model and based on that to find the geometry that gives the best efficiency to the proposed service. (author)

  1. Optimization in obtaining PLA nanofibers/nHAP for pharmaceuticals release; Otimizacao na obtencao de nanofibras de PLA/nHAP para liberacao de farmacos

    Energy Technology Data Exchange (ETDEWEB)

    Becaro, A.A.; Paris, E.C.; Mattoso, L.H.C., E-mail: elaine.paris@embrapa.br [EMBRAPA Instrumentacao, Sao Carlos, SP (Brazil); Sciena, C.R.; Malafatti, J.D. [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil). Departamento de Quimica

    2016-07-01

    Hydroxyapatite (HAP) belongs to the family of calcium apatites. In nanometric form (nHAP) can be used as a drug carrier. The objective was to improve PLA nanofibers with nHAP insert for use in drug delivery. nHAP were obtained by coprecipitation method and characterized by XRD and TEM techniques. PLA fibers (10%) and 5% nHAP were obtained at a distance of 6 cm and flow rate of 0.1, 0.3 and 0.5 ml h{sup -1}, and characterized by SEM. The nHAP were single phase with rod shape, rounded tip and from 10 to 20 nm in diameter. The fibers obtained from pure PLA had to be more porous than in the presence of HAP. The diameters ranged from 0.2 to 2.4 micrometers. Among the fibers obtained that showed the best result was to flow 0.3 ml h{sup -1}. (author)

  2. Automatic optimization of a nuclear reactor reload using the algorithm Ant-Q; A otimizacao automatica da recarga nuclear utilizando o algoritmo Ant-Q

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Liana; Schirru, Roberto [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2002-07-01

    The nuclear fuel reload optimization is a NP-Complete combinatorial optimization problem. For decades this problem was solved using an expert's knowledge. From the eighties, however there have been efforts to automatic fuel reload and the more recent ones show the Genetic Algorithm's (GA) efficiency on this problem. Following this trend, our aim is to optimization nuclear fuel reload using Ant-Q, artificial theory based algorithms. Ant-Q's results on the Traveling salesman Problem, which is conceptuality similar to fuel reload, are better than GA's. Ant-Q was tested in real application on the cycle 7 reload of Angra I. Comparing Ant-Q result with the GA's, it can be verified that, even without a local heuristics, the former algorithm, as it superiority comparing the GA in Angra I show. Is a valid technique to solve the nuclear fuel reload problem. (author)

  3. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning; Otimizacao aplicada ao planejamento de politicas de testes em sistemas nucleares por enxame de particulas

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Newton Norat

    2006-12-15

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  4. Non‐diluted seawater enhances nasal ciliary beat frequency and wound repair speed compared to diluted seawater and normal saline

    Science.gov (United States)

    Bonnomet, Arnaud; Luczka, Emilie; Coraux, Christelle

    2016-01-01

    Background The regulation of mucociliary clearance is a key part of the defense mechanisms developed by the airway epithelium. If a high aggregate quality of evidence shows the clinical effectiveness of nasal irrigation, there is a lack of studies showing the intrinsic role of the different irrigation solutions allowing such results. This study investigated the impact of solutions with different pH and ionic compositions, eg, normal saline, non‐diluted seawater and diluted seawater, on nasal mucosa functional parameters. Methods For this randomized, controlled, blinded, in vitro study, we used airway epithelial cells obtained from 13 nasal polyps explants to measure ciliary beat frequency (CBF) and epithelial wound repair speed (WRS) in response to 3 isotonic nasal irrigation solutions: (1) normal saline 0.9%; (2) non‐diluted seawater (Physiomer®); and (3) 30% diluted seawater (Stérimar). The results were compared to control (cell culture medium). Results Non‐diluted seawater enhanced the CBF and the WRS when compared to diluted seawater and to normal saline. When compared to the control, it significantly enhanced CBF and slightly, though nonsignificantly, improved the WRS. Interestingly, normal saline markedly reduced the number of epithelial cells and ciliated cells when compared to the control condition. Conclusion Our results suggest that the physicochemical features of the nasal wash solution is important because it determines the optimal conditions to enhance CBF and epithelial WRS thus preserving the respiratory mucosa in pathological conditions. Non‐diluted seawater obtains the best results on CBF and WRS vs normal saline showing a deleterious effect on epithelial cell function. PMID:27101776

  5. Non-diluted seawater enhances nasal ciliary beat frequency and wound repair speed compared to diluted seawater and normal saline.

    Science.gov (United States)

    Bonnomet, Arnaud; Luczka, Emilie; Coraux, Christelle; de Gabory, Ludovic

    2016-10-01

    The regulation of mucociliary clearance is a key part of the defense mechanisms developed by the airway epithelium. If a high aggregate quality of evidence shows the clinical effectiveness of nasal irrigation, there is a lack of studies showing the intrinsic role of the different irrigation solutions allowing such results. This study investigated the impact of solutions with different pH and ionic compositions, eg, normal saline, non-diluted seawater and diluted seawater, on nasal mucosa functional parameters. For this randomized, controlled, blinded, in vitro study, we used airway epithelial cells obtained from 13 nasal polyps explants to measure ciliary beat frequency (CBF) and epithelial wound repair speed (WRS) in response to 3 isotonic nasal irrigation solutions: (1) normal saline 0.9%; (2) non-diluted seawater (Physiomer®); and (3) 30% diluted seawater (Stérimar). The results were compared to control (cell culture medium). Non-diluted seawater enhanced the CBF and the WRS when compared to diluted seawater and to normal saline. When compared to the control, it significantly enhanced CBF and slightly, though nonsignificantly, improved the WRS. Interestingly, normal saline markedly reduced the number of epithelial cells and ciliated cells when compared to the control condition. Our results suggest that the physicochemical features of the nasal wash solution is important because it determines the optimal conditions to enhance CBF and epithelial WRS thus preserving the respiratory mucosa in pathological conditions. Non-diluted seawater obtains the best results on CBF and WRS vs normal saline showing a deleterious effect on epithelial cell function. © 2016 The Authors International Forum of Allergy & Rhinology, published by ARSAAOA, LLC.

  6. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960)

    International Nuclear Information System (INIS)

    Bovard, P.; Candillon, C.

    1960-01-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [fr

  7. Stable isotope dilution analysis by thermal ionization mass spectrometry. Pt. 2

    International Nuclear Information System (INIS)

    Broekman, A.; Raaphorst, J.G. van

    1984-01-01

    The combination of stable isotope dilution analysis (SIDA) and thermal ionization mass spectrometry (TIMS) is in use for lead and uranium determination at milligram per kilogram levels for over 20 years. However, several other elements can also be determined accurately by SIDA/TIMS. In this study the determinations of cadmium and copper are described. Details of the digestion, electrochemical and ion-exchange separations and the loading of the elements on a filament are given. The advantages of the SIDA/TIMS technique are shown and illustrated with results for several certified reference materials. (orig.) [de

  8. The measurement of water vapor permeability of glove materials using dilute tritiated water

    International Nuclear Information System (INIS)

    Doughty, D.H.

    1982-01-01

    As fusion technology progresses, there will be an increasing need to handle tritium and tritiated compounds. Protective clothing, especially drybox gloves, must be an effective barrier to minimize worker exposure. The water vapor permeability of glove materials and finished glove constructions is a crucial property of drybox gloves and is not sufficiently well characterized. We have built an apparatus that measures water vapor permeability of elastomers using dilute tritiated water. The technique is more sensitive than other methods currently available and allows us to make measurements on materials and under conditions previously inaccessible. In particular, we present results on laminated drybox gloves for which data is not currently available. (orig.)

  9. ERM booster vaccination of Rainbow trout using diluted bacterin

    DEFF Research Database (Denmark)

    Schmidt, Jacob Günther; Henriksen, Niels H.; Buchmann, Kurt

    2016-01-01

    under laboratory conditions extend the protection period. The present field study investigated the applicability of the method under practical farming conditions (freshwater earth ponds supplied by stream water). Primary immersion vaccination of trout (3–4 g) for 30 s in Y. ruckeri bacterin (diluted 1......Enteric Red Mouth Disease ERM caused by Yersinia ruckeri infection is associated with morbidity and mortality in salmonid farming but immersion vaccination of fry may confer some protection for a number of months. Revaccination of rainbow trout, even by use of diluted ERM immersion vaccine, can......:10) in April 2015 was followed 3 months later (July 2015) by 1 h bathing of rainbow trout in bacterin (diluted 1:650 or 1:1700) in order to evaluate if this time saving vaccination methodology can improve immunity and protection. Trout were subjected in farms to natural Y. ruckeri exposure in June and July...

  10. Moderate Dilution of Copper Slag by Natural Gas

    Science.gov (United States)

    Zhang, Bao-jing; Zhang, Ting-an; Niu, Li-ping; Liu, Nan-song; Dou, Zhi-he; Li, Zhi-qiang

    2018-01-01

    To enable use of copper slag and extract the maximum value from the contained copper, an innovative method of reducing moderately diluted slag to smelt copper-containing antibacterial stainless steel is proposed. This work focused on moderate dilution of copper slag using natural gas. The thermodynamics of copper slag dilution and ternary phase diagrams of the slag system were calculated. The effects of blowing time, temperature, matte settling time, and calcium oxide addition were investigated. The optimum reaction conditions were identified to be blowing time of 20 min, reaction temperature of 1250°C, settling time of 60 min, CaO addition of 4% of mass of slag, natural gas flow rate of 80 mL/min, and outlet pressure of 0.1 MPa. Under these conditions, the Fe3O4 and copper contents of the residue were 7.36% and 0.50%, respectively.

  11. Thermal diffusion in dilute nanofluids investigated by photothermal interferometry

    International Nuclear Information System (INIS)

    Philip, J; Nisha, M R

    2010-01-01

    We have carried out a theoretical analysis of the dependence of the particle mass fraction on the thermal diffusivity of dilute suspensions of nanoparticles in liquids (dilute nanofluids). The analysis takes in to account adsorption of an ordered layer of solvent molecules around the nanoparticles. It is found that thermal diffusivity decreases with mass fraction for sufficiently small particle sizes. Beyond a critical particle size thermal diffusivity begins to increase with mass fraction for the same system. The results have been verified experimentally by measuring the thermal diffusivity of dilute suspensions of TiO 2 nanoparticles dispersed in polyvinyl alcohol (PVA) medium. The effect is attributed to Kapitza resistance of thermal waves in the medium.

  12. Multi-element isotope dilution analyses using ICP-MS

    International Nuclear Information System (INIS)

    Volpe, A.M.

    1996-01-01

    Presently, 37 elements ranging from light (Li,B) through transition metals, noble, rare earth and heavy elements, to actinides and transuranics (Pu, Am, Cm) are measured by isotope dilution at Lawrence Livermore National Laboratory. Projects range from geological and hydrological to biological. The research goal is to measure accurately many elements present in diverse matrices at trace (ppb) levels using isotope dilution methods. Major advantages of isotope dilution methods are accuracy, elimination of ion intensity calibration, and quantitation for samples that require chemical separation. Accuracy depends on tracer isotope calibration, tracer-sample isotopic equilibration, and appropriate background, isobaric and mass bias corrections. Propagation of isotope ratio error due to improper tracer isotope addition is a major concern with multi-element analyses when abundances vary widely. 11 refs., 3 figs

  13. Optimization of transfer and storage using modeling and simulation tools; Otimizacao da transferencia e estocagem utilizando ferramentas de modelagem e simulacao

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Mario Jorge; Barbosa, Guilherme de Aquino [PETROBRAS, Rio de Janeiro, RJ (Brazil)]. E-mail: mariojl@petrobras.com.br; Beal, Claudio Rodrigo [PETROBRAS, Araucaria, PR (Brazil). Refinaria Presidente Getulio Vargas

    2003-12-01

    The mathematical modeling of Transfer and Storage Systems (TE) has been an important tool in support the decision making, for, due to the large number of its interfaces and the complexity of its interactions, many times it's difficult to predict all possible consequences of factors affecting the area (Revamps, new units, maintenance, market, etc.) and without the support of a consistent mathematical model, intuition some times leads to erroneous conclusions. The application of simulation techniques to models enables a wider use, for through the utilization of probabilistic models representing interfaces (market, supply, production, laboratory, etc.) it is possible to simulate logistic costs and service level in different scenarios, subsidizing technical and managerial decisions leading to optimization of inventories. Major advantages are: once it is created, a model can be used several times to assess the proposed projects and policies; the analysis methodology used by simulation enables the assessment of a proposed system, even if the entry data are still under form of schemes or drafts; simulation is generally easier to be applied than analytical methods. A partnership was created among several of PETROBRAS' managers for the development of the so-called 'Integral and Integrated Model of Transfer and Storage' or 'M2TE'. Examples of application of such model to some refineries and the relevant results obtained are reported below. (author)

  14. How Consumers’ Styles of Thinking Can Control Brand Dilution

    Directory of Open Access Journals (Sweden)

    Monga Alokparna Basu

    2018-05-01

    Full Text Available Understanding consumers’ ways of thinking can help identify strategies to limit brand damage and elicit more favorable reactions from disapproving consumers. Analytic thinkers’ beliefs about a brand are diluted when they see negative information; those of holistic thinkers remain unaffected. While both analytic and holistic thinkers blame the brand equally for quality and manufacturing problems, holistic thinkers are more likely to blame contextual factors outside of the brand than analytic thinkers. This ability of holistic thinkers to focus on the outside context is the reason why their brand beliefs are not diluted.

  15. Computer registration of radioactive indicator-dilution curves.

    Science.gov (United States)

    Shepherd, A P; Perry, M A; Alexander, G M; Granger, D N; Riedel, G L; Kvietys, P R; Franke, C P

    1983-12-01

    A system is described for recording indicator-dilution curves produced by gamma radiation-emitting tracers. The system consists of a flow-through cuvette in a well counter, appropriate commercially available gamma radiation-detecting equipment, an Apple II computer, and a two-channel pulse-counting interface of our own design. With the counting interface and the software described here, an investigator can simultaneously record two indicator-dilution curves produced by gamma emitters. Instead of having to wait hours or days for results, the investigator can watch the data being recorded and display the results in graphic form almost immediately after each injection.

  16. GRAIN-BOUNDARY PRECIPITATION UNDER IRRADIATION IN DILUTE BINARY ALLOYS

    Institute of Scientific and Technical Information of China (English)

    S.H. Song; Z.X. Yuan; J. Liu; R.G.Faulkner

    2003-01-01

    Irradiation-induced grain boundary segregation of solute atoms frequently bring about grain boundary precipitation of a second phase because of its making the solubility limit of the solute surpassed at grain boundaries. Until now the kinetic models for irradiation-induced grain boundary precipitation have been sparse. For this reason, we have theoretically treated grain boundary precipitation under irradiation in dilute binary alloys. Predictions ofγ'-Ni3Si precipitation at grain boundaries ave made for a dilute Ni-Si alloy subjected to irradiation. It is demonstrated that grain boundary silicon segregation under irradiation may lead to grain boundaryγ'-Ni3 Si precipitation over a certain temperature range.

  17. Dilution and volatilization of groundwater contaminant discharges in streams

    DEFF Research Database (Denmark)

    Aisopou, Angeliki; Bjerg, Poul Løgstrup; Sonne, Anne Thobo

    2015-01-01

    measurement. The solution was successfully applied to published field data obtained in a large and a small Danish stream and provided valuable information on the risk posed by the groundwater contaminant plumes. The results provided by the dilution and volatilization model are very different to those obtained......An analytical solution to describe dilution and volatilization of a continuous groundwater contaminant plume into streams is developed for risk assessment. The location of groundwater plume discharge into the stream (discharge through the side versus bottom of the stream) and different...

  18. Test plan for tank 241-AN-104 dilution studies

    International Nuclear Information System (INIS)

    Herting, D.L.

    1998-01-01

    Tank 241-AN-104 (104-AN) has been identified as the one of the first tanks to be retrieved for low level waste pretreatment and immobilization. Retrieval of the tank waste will require dilution. Laboratory tests are needed to determine the amount and type of dilution required for safe retrieval and transfer of feed and to re-dissolve major soluble sodium salts while not precipitating out other salts. The proposed laboratory tests are described in this document. Tank 241-AN-104 is on the Hydrogen Watch List

  19. Dynamics of dilute disordered models: A solvable case

    International Nuclear Information System (INIS)

    Semerjian, Guilhem; Cugliandolo, Leticia F.

    2003-09-01

    We study the dynamics of a dilute spherical model with two body interactions and random exchanges. We analyze the Langevin equations and we introduce a functional variational method to study generic dilute disordered models. A crossover temperature replaces the dynamic transition of the fully-connected limit. There are two asymptotic regimes, one determined by the central band of the spectral density of the interactions and a slower one determined by localized configurations on sites with high connectivity. We confront the behavior of this model to the one of real glasses. (author)

  20. High field Moessbauer study of dilute Ir-(Fe) alloys

    International Nuclear Information System (INIS)

    Takabatake, Toshiro; Mazaki, Hiromasa; Shinjo, Teruya.

    1981-01-01

    The magnetic behavior of very dilute Fe impurities in Ir has been studied by means of Moessbauer measurement in external fields up to 80 kOe at 4.2 K. The saturation hyperfine field increases in proportion to the external field up to the maximum magnetic field available. This means that for a localized spin fluctuation system IrFe, the effective magnetic moment associated with Fe impurities is induced in proportion to the external field. No anomalous spectrum was observed with a very dilute sample (--10 ppm 57 Co), indicating that the interaction between impurities is responsible for the anomalous spectrum previously observed with a less homogeneous sample. (author)

  1. Introduction to the Physics of Diluted Magnetic Semiconductors

    CERN Document Server

    Gaj, Jan A

    2010-01-01

    The book deals with diluted magnetic semiconductors, a class of materials important to the emerging field of spintronics. In these materials semiconducting properties, both transport and optical, are influenced by the presence of magnetic ions. It concentrates on basic physical mechanisms (e.g. carrier-ion and ion-ion interactions) and resulting phenomena (e.g. magnetic polaron formation and spin relaxation). Introduction to the Physics of Diluted Magnetic Semiconductors is addressed to graduate-level and doctoral students and young researchers entering the field. The authors have been actively involved in the creation of this branch of semiconductor physics.

  2. EXPLOT - decision support system for optimization of oil exploitation; EXPLOT - sistema de apoio a decisao para a otimizacao da explotacao de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Tupac Valdivia, Yvan Jesus; Almeida, Luciana Faletti; Pacheco, Marco Aurelio Cavalcanti; Vellasco, Marley Maria Bernardes Rebuzzi [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Eletrica. Lab. de Inteligencia Computacional], e-mail: yvantv@ele.puc-rio.br, e-mail: faletti@ele.puc-rio.br, e-mail: marco@ele.puc-rio.br, e-mail: marley@ele.puc-rio.br

    2007-06-15

    The present work offers a decision supporting system, integrated in different techniques (genetic algorithms, cultural algorithms, co-evolution, neural networks, neuro fuzzy model and distributed processing) for optimization of exploitation of oil reservoirs. The EXPLOT system identifies exploitation alternatives and determines the quantity, position, type (producers or injectors) and structure (horizontal or vertical) of wells, that maximize the present net value of the alternative (VPL). The EXPLOT system is composed of three main modules: the optimizer (genetic algorithms, cultural algorithms and co-evolution), the Production Curves Obtention (approximator neuro fuzzy-NFHB of the production curve) and the present net value calculation. To estimate the VPL of each developmental alternative, the system utilizes a reservoir simulator, specifically the IMEX, although other simulators may be utilized. In addition to these technologies, the system also utilizes distributed processing, based on the CORBA architecture for distributed execution of the reservoir simulator in a computer network, which significantly reduces the total optimization time. The EXPLOT system was already tested in different examples of oil fields. Results obtained so far are considered consistent according to the opinion of specialists, who consider the system as a new decision support tool concept in the area. The differences of EXPLOT are not only to be found in its efficient optimization model, but also in its interface, through which the specialists interact with the system, introducing project recommendations (e.g., five-spot wells), commanding a localized search for best solutions, sizing the simulation network and monitoring simulation distribution by means of available networks. The EXPLOT system is the result of joint research between CENPES and the Applied Computational Intelligence Lab, PUC-Rio, accomplished during the past three years. The continuation of this research project expands

  3. Modeling of dilute and dense dispersed fluid-particle flow

    Energy Technology Data Exchange (ETDEWEB)

    Laux, Harald

    1998-08-01

    A general two-fluid model is derived and applied in CFD computations to various test cases of important industrial multiphase flows. It is general in the sense of its applicability to dilute and dense dispersed fluid-particle flows. The model is limited to isothermal flow without mass transfer and only one particle phase is described. The instantaneous fluid phase equations, including the phase interaction terms, are derived from a volume averaging technique, and the instantaneous particle phase equations are derived from the kinetic theory of granular material. Whereas the averaging procedure, the treatment of the interaction terms, and the kinetic theory approach have been reported in literature prior to this work the combination of the approaches is new. The resulting equations are derived without ambiguity in the interpretation of the particle phase pressure (equation-of-state of particle phase). The basic modeling for the particle phase is improved in two steps. Because in the basic modeling only stresses due to kinetic and collisional interactions are included, a simple model for an effective viscosity is developed in order to allow also frictional stresses within the particle phase. Moreover, turbulent stresses and turbulent dispersion of particles play often an important role for the transport processes. Therefore in a second step, a two-equation turbulence model for both fluid and particle phase turbulence is derived by applying the phasic average to the instantaneous equations. The resulting k-{epsilon}-k{sup d}-{epsilon}{sup d} model is new. Mathematical closure is attempted such that the resulting set of equations is valid for both dilute arid dense flows. During the development of the closure relations a clear distinction is made between granular or ''viscous'' microscale fluctuations and turbulent macro scale fluctuations (true particle turbulence) within the particle phase. The set of governing equations is discretized by using a

  4. Modeling of dilute and dense dispersed fluid-particle flow

    Energy Technology Data Exchange (ETDEWEB)

    Laux, Harald

    1998-08-01

    A general two-fluid model is derived and applied in CFD computations to various test cases of important industrial multiphase flows. It is general in the sense of its applicability to dilute and dense dispersed fluid-particle flows. The model is limited to isothermal flow without mass transfer and only one particle phase is described. The instantaneous fluid phase equations, including the phase interaction terms, are derived from a volume averaging technique, and the instantaneous particle phase equations are derived from the kinetic theory of granular material. Whereas the averaging procedure, the treatment of the interaction terms, and the kinetic theory approach have been reported in literature prior to this work the combination of the approaches is new. The resulting equations are derived without ambiguity in the interpretation of the particle phase pressure (equation-of-state of particle phase). The basic modeling for the particle phase is improved in two steps. Because in the basic modeling only stresses due to kinetic and collisional interactions are included, a simple model for an effective viscosity is developed in order to allow also frictional stresses within the particle phase. Moreover, turbulent stresses and turbulent dispersion of particles play often an important role for the transport processes. Therefore in a second step, a two-equation turbulence model for both fluid and particle phase turbulence is derived by applying the phasic average to the instantaneous equations. The resulting k-{epsilon}-k{sup d}-{epsilon}{sup d} model is new. Mathematical closure is attempted such that the resulting set of equations is valid for both dilute arid dense flows. During the development of the closure relations a clear distinction is made between granular or ''viscous'' microscale fluctuations and turbulent macro scale fluctuations (true particle turbulence) within the particle phase. The set of governing equations is discretized by using a finite volume method

  5. EDITORIAL: Focus on Dilute Magnetic Semiconductors FOCUS ON DILUTE MAGNETIC SEMICONDUCTORS

    Science.gov (United States)

    Chambers, Scott A.; Gallagher, Bryan

    2008-05-01

    This focus issue of New Journal of Physics is devoted to the materials science of dilute magnetic semiconductors (DMS). A DMS is traditionally defined as a diamagnetic semiconductor doped with a few to several atomic per cent of some transition metal with unpaired d electrons. Several kinds of dopant-dopant interactions can in principle couple the dopant spins leading to a ferromagnetic ground state in a dilute magnetic system. These include superexchange, which occurs principally in oxides and only between dopants with one intervening oxygen, and double exchange, in which dopants of different formal charges exchange an electron. In both of these mechanisms, the ferromagnetic alignment is not critically dependent on free carriers in the host semiconductor because exchange occurs via bonds. A third mechanism, discovered in the last few years, involves electrons associated with lattice defects that can apparently couple dopant spins. This mechanism is not well understood. Finally, the most desirable mechanism is carrier-mediated exchange interaction in which the dopant spins are coupled by itinerant electrons or holes in the host semiconductor. This mechanism introduces a fundamental link between magnetic and electrical transport properties and offers the possibility of new spintronic functionalities. In particular electrical gate control of ferromagnetism and the use of spin polarized currents to carry signals for analog and digital applications. The spin light emitting diode is a prototypical device of this kind that has been extensively used to characterize the extent of spin polarization in the active light emitting semiconductor heterostructure. The prototypical carrier mediated ferromagnetic DMS is Mn-doped GaAs. This and closely related narrow gap III-V materials have been very extensively studied. Their properties are generally quite well understood and they have led to important insights into fundamental properties of ferromagnetic systems with strong spin

  6. Dosage of plutonium by isotopic dilution in irradiated fuels; Dosage du plutonium par dilution isotopique dans les combustibles irradies

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Plutonium determination in irradiated fuels has been carried out for several years by isotopic dilution by Sebaci and SSM in collaboration. SECACI has made available to the SSM the necessary space and equipment in its Fontenay laboratories. This work has shown the importance of the valency cycle which should make it possible to obtain a uniform isotopic distribution in sample tracer mixtures, and also a satisfactory U/Pu separation. Now it has been noticed that the presence of an excess of uranium considerably modifies the oxidation-reduction reaction kinetics of the plutonium. We have therefore been led to change certain parts of the operational technique so as to have an efficient cycle and to thereby improve the U/Pu separation; the stability of the thermionic emission of the plutonium, connected to the quantity of residual uranium, has at the same time been improved and we can now carry out more precise isotopic analyses. We have also tried to eliminate as far as possible the isotopic contaminations by:using a more rational operational method; the equipment used has been the object of a special study. The evaporations are carried out so as to prevent the formation of saturated vapours inside the glove box. The material which cannot be changed after each operation is carefully cleaned every time a new sample is treated. With this technique, a second calibration of the tracer T{sub 2} has been undertaken using a new standard solution. This solution has been prepared very carefully by weighing uranium and plutonium of known chemical purity, and we believe that it can be guaranteed to be a good reference solution. The value of the {sup 233}U/{sup 242}Pu ratio of the tracer has been obtained with a relative accuracy of 0,5 per cent. This modified method is now being applied to the analysis of rods irradiated in G-3. (author) [French] La determination du plutonium par dilution isotopique dans les combustibles irradies est pratiquee depuis plusieurs annees en

  7. post-jomtien policy dilutions: infrastructural & quality norms

    Indian Academy of Sciences (India)

    Operation Blackboard norms diluted – from 3 teachers-3 rooms per primary school to 2 teachers-2 rooms per primary school. Regular teacher replaced by under-qualified, untrained, under-paid Para-teachers appointed on short-term contracts. EGS – No provision for school buildings or teaching aids. Multi-grade Teaching ...

  8. Coherence and stiffness of spin waves in diluted ferromagnets

    Czech Academy of Sciences Publication Activity Database

    Turek, Ilja; Kudrnovský, Josef; Drchal, Václav

    2016-01-01

    Roč. 94, č. 17 (2016), č. článku 174447. ISSN 2469-9950 R&D Projects: GA ČR GA15-13436S Institutional support: RVO:68081723 ; RVO:68378271 Keywords : spin wave s * diluted ferromagnets * disordered systems Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.836, year: 2016

  9. A simple approximation method for dilute Ising systems

    International Nuclear Information System (INIS)

    Saber, M.

    1996-10-01

    We describe a simple approximate method to analyze dilute Ising systems. The method takes into consideration the fluctuations of the effective field, and is based on a probability distribution of random variables which correctly accounts for all the single site kinematic relations. It is shown that the simplest approximation gives satisfactory results when compared with other methods. (author). 12 refs, 2 tabs

  10. Determination of dilution and quality control of total and anti ...

    African Journals Online (AJOL)

    Objective: To determine the correct dilution and Quality control commercial ELISA of total and anti-measles antibodies for HIV infected pregnant women. Design: A laboratory based study. Setting: The University of Nairobi, Department of Paediatrics laboratory. Subjects: HIV infected pregnant women enrolled and exposed to ...

  11. Quality of potential harmonics expansion method for dilute Bose ...

    Indian Academy of Sciences (India)

    Abstract. We present and examine an approximate but ab initio many-body approach, viz., potential harmonics expansion method (PHEM), which includes two-body correla- tions for dilute Bose–Einstein condensates. Comparing the total ground state energy for three trapped interacting bosons calculated in PHEM with the ...

  12. Bioethanol productions from rice polish by optimization of dilute acid ...

    African Journals Online (AJOL)

    Lignocellulose materials are abundant renewable resource for the production of biofuel from fermentative organism (Sacchromyces cervesiae). Rice polish is cheapest and abundant lignocelluloses resource and has potential to produce bioethanol. The main steps for the conversion of biomass into glucose required dilute ...

  13. Inhibition Effect of Deanol on Mild Steel Corrosion in Dilute ...

    African Journals Online (AJOL)

    NICOLAAS

    2014-06-23

    Jun 23, 2014 ... The influence of deanol on the corrosion behaviour of mild steel in dilute sulphuric acid with sodium ... the formation of a complex precipitate of protective film, which ... silicon carbide abrasive papers of 80, 120, 220, 800 and 1000 grit ...... ions in sulphuric acid on the corrosion behaviour of stainless steel,.

  14. Kinetic-sound propagation in dilute gas mixtures

    International Nuclear Information System (INIS)

    Campa, A.; Cohen, E.G.D.

    1989-01-01

    Kinetic sound is predicted in dilute disparate-mass binary gas mixtures, propagating exclusively in the light compound and much faster than ordinary sound. It should be detectable by light-scattering experiments, as an extended shoulder in the scattering cross section for large frequencies. As an example, H 2 -Ar mixtures are discussed

  15. Thermodynamics of a dilute XX chain in a field

    Energy Technology Data Exchange (ETDEWEB)

    Timonin, P. N., E-mail: pntim@live.ru [Southern Federal University, Physics Research Institute (Russian Federation)

    2016-06-15

    Gapless phases in ground states of low-dimensional quantum spin systems are rather ubiquitous. Their peculiarity is a remarkable sensitivity to external perturbations due to permanent criticality of such phases manifested by a slow (power-low) decay of pair correlations and the divergence of the corresponding susceptibility. A strong influence of various defects on the properties of the system in such a phase can then be expected. Here, we consider the influence of vacancies on the thermodynamics of the simplest quantum model with a gapless phase, the isotropic spin-1/2 XX chain. The existence of the exact solution of this model gives a unique opportunity to describe in detail the dramatic effect of dilution on the gapless phase—the appearance of an infinite series of quantum phase transitions resulting from level crossing under the variation of a longitudinal magnetic field. We calculate the jumps in the field dependences of the ground-state longitudinal magnetization, susceptibility, entropy, and specific heat appearing at these transitions and show that they result in a highly nonlinear temperature dependence of these parameters at low T. Also, the effect of enhancement of the magnetization and longitudinal correlations in the dilute chain is established. The changes of the pair spin correlators under dilution are also analyzed. The universality of the mechanism of the quantum transition generation suggests that similar effects of dilution can also be expected in gapless phases of other low-dimensional quantum spin systems.

  16. 21 CFR 172.710 - Adjuvants for pesticide use dilutions.

    Science.gov (United States)

    2010-04-01

    ... Section 172.710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES PERMITTED FOR DIRECT ADDITION TO FOOD FOR HUMAN CONSUMPTION Other Specific Usage Additives § 172.710 Adjuvants for pesticide use dilutions. The...

  17. Electrochemical reduction of metal ions in dilute solution using hydrogen

    NARCIS (Netherlands)

    Portegies Zwart, I.; Wijnbelt, E.C.W.; Janssen, L.J.J.

    1995-01-01

    Reduction of metal ions in dilute solutions is of great interest for purification of waste waters and process liquids. A new electrochemical cell has been introduced. This cell - a GBC-cell - is a combination of a gasdiffusion electrode in direct contact with a packed bed of carbon particles.

  18. Electrochemical reduction of dilute chromate solutions on carbon felt electrodes

    NARCIS (Netherlands)

    Frenzel, Ines; Frenzel, I.; Holdik, Hans; Barmashenko, Vladimir; Stamatialis, Dimitrios; Wessling, Matthias

    2006-01-01

    Carbon felt is a potential material for electrochemical reduction of chromates. Very dilute solutions may be efficiently treated due to its large specific surface area and high porosity. In this work, the up-scaling of this technology is investigated using a new type of separated cell and

  19. Electrochemical reduction of nickel ions from dilute solutions

    NARCIS (Netherlands)

    Njau, K.N.; Janssen, L.J.J.

    1995-01-01

    Electrochemical reduction of nickel ions in dilute solution using a divided GBC-cell is of interest for purification of waste waters. A typical solution to be treated is the effluent from steel etching processes which contain low quantities of nickel, chromate and chromium ions. Reduction of

  20. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240 Section 864.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  1. Phase diagrams of site diluted ferromagnetic thin film

    International Nuclear Information System (INIS)

    Hamedoun, M.; Bouslykhane, K.; Bakrim, H.; Hourmatallah, A.; Benzakour, N.; Masrour, R.

    2006-01-01

    The phase transition properties of Ising, classical XY and Heisenberg of diluted ferromagnetic thin film are studied by the method of exact high-temperature series expansions extrapolated with the Pade approximants method. The reduced critical temperature τ c of the diluted ferromagnetic thin films is studied as a function of film thickness L and the exchange interactions in the bulk J b , in the surface J s and between surface and nearest-neighbour layer J - bar . It is found that τ c increases with the exchange interactions of surface and L. The magnetic phase diagram (τ c versus dilution x) is obtained. A critical value of the surface exchange interaction above which the surface magnetism appears is obtained. The dependence of the critical parameter of surface reduced coupling R 2 c as a function of the dilution x and the ratio of the exchange interaction between the surface and nearest-neighbour layer to the bulk one R 1 for the three studied models has been investigated. The percolation threshold is defined as the concentration x p at which τ c =0. The obtained values are x p ∼0.2 in the bulk and x p ∼0.4 at the surface

  2. Determination of photooxygenation products of rotenone with isotope dilution method

    International Nuclear Information System (INIS)

    Chubachi, Mitsuo; Hamada, Masayuki

    1975-01-01

    When rotenone dissolved in certain solvent was photochemically oxidized, rotenolones, dehydrorotenone and rotenonone were obtained as main products. In order to determine the quantitative yields of these compounds in photooxygenation products, four compounds mentioned above were labeled with carbon-14 and the isotope dilution method by these labeled compounds was applied to the product analysis. (auth.)

  3. Analysis of boron dilution in a four-loop PWR

    International Nuclear Information System (INIS)

    Sun, J.G.; Sha, W.T.

    1995-03-01

    Thermal mixing and boron dilution in a pressurized water reactor were analyzed with COMMIX codes. The reactor system was the four-loop Zion reactor. Two boron dilution scenarios were analyzed. In the first scenario, the plant is in cold shutdown and the reactor coolant system has just been filled after maintenance on the steam generators. To flush the air out of the steam generator tubes, a reactor coolant pump (RCP) is started, with the water in the pump suction line devoid of boron and at the same temperature as the coolant in the system. In the second scenario, the plant is at hot standby and the reactor coolant system has been heated to operating temperature after a long outage. It is assumed that an RCP is started, with the pump suction line filled with cold unborated water, forcing a slug of diluted coolant down the downcomer and subsequently through the reactor core. The subsequent transient thermal mixing and boron dilution that would occur in the reactor system is simulated for these two scenarios. The reactivity insertion rate and the total reactivity are evaluated and a sensitivity study is performed to assess the accuracy of the numerical modeling of the geometry of the reactor coolant system

  4. Simplified Method for Groundwater Treatment Using Dilution and Ceramic Filter

    Science.gov (United States)

    Musa, S.; Ariff, N. A.; Kadir, M. N. Abdul; Denan, F.

    2016-07-01

    Groundwater is one of the natural resources that is not susceptible to pollutants. However, increasing activities of municipal, industrial, agricultural or extreme land use activities have resulted in groundwater contamination as occured at the Research Centre for Soft Soil Malaysia (RECESS), Universiti Tun Hussein Onn Malaysia (UTHM). Thus, aims of this study is to treat groundwater by using rainwater and simple ceramic filter as a treatment agent. The treatment uses rain water dilution, ceramic filters and combined method of dilute and filtering as an alternate treatment which are simple and more practical compared to modern or chemical methods. The water went through dilution treatment processes able to get rid of 57% reduction compared to initial condition. Meanwhile, the water that passes through the filtering process successfully get rid of as much as 86% groundwater parameters where only chloride does not pass the standard. Favorable results for the combination methods of dilution and filtration methods that can succesfully eliminate 100% parameters that donot pass the standards of the Ministry of Health and the Interim National Drinking Water Quality Standard such as those found in groundwater in RECESS, UTHM especially sulfate and chloride. As a result, it allows the raw water that will use clean drinking water and safe. It also proves that the method used in this study is very effective in improving the quality of groundwater.

  5. In vitro dilutions of thioridaxine with potential to enhance antibiotic ...

    African Journals Online (AJOL)

    Gram staining, catalase test and coagulase test were done on the resulting colonies to further confirm the strains as S. aureus. Antibiotic susceptibility test was done by agar disc diffusion method using sterile Mueller- Hinton agar plates before and after treatment with laboratory dilutions of thioridaxine. S. aureus strains 1, ...

  6. Time correlation functions and transport coefficients in a dilute superfluid

    International Nuclear Information System (INIS)

    Kirkpatrick, T.R.; Dorfman, J.R.

    1985-01-01

    Time correlation functions for the transport coefficients in the linear Landau-Khalatnikov equations are derived on the basis of a formal theory. These Green--Kubo expressions are then explicitly evaluated for a dilute superfluid and the resulting transport coefficiencts are shown to be identical to those obtained previously by using a distribution function method

  7. Optimisation of Dilute Sulphuric Acid Hydrolysis of Waste ...

    African Journals Online (AJOL)

    Dilute sulphuric acid hydrolysis of waste paper was investigated in this study. The effects of acid concentration, time, temperature and liquid to solid ratio on the total reducing sugar concentration were studied over three levels using a four variable Box-Behnken design (BBD). A statistical model was developed for the ...

  8. Atomic displacements in dilute alloys of Cr, Nb and Mo

    Indian Academy of Sciences (India)

    physics pp. 497–514. Atomic displacements in dilute alloys of Cr, Nb and Mo ... used to calculate dynamical matrix and the impurity-induced forces up to second nearest ... origin, the lattice is strained, and the host atoms get displaced to new ...

  9. Color dilution alopecia in a blue Doberman pinscher crossbreed

    OpenAIRE

    Perego, Roberta; Proverbio, Daniela; Roccabianca, Paola; Spada, Eva

    2009-01-01

    A 6-year-old male, blue Doberman pinscher crossbreed was presented with coat abnormalities; in particular, flank alopecia and pruritus. Based on medical the history, clinical evidence, and histopathological examination, color dilution alopecia was diagnosed. The dog was with oral melatonin treated for 3 months without success.

  10. Color dilution alopecia in a blue Doberman pinscher crossbreed.

    Science.gov (United States)

    Perego, Roberta; Proverbio, Daniela; Roccabianca, Paola; Spada, Eva

    2009-05-01

    A 6-year-old male, blue Doberman pinscher crossbreed was presented with coat abnormalities; in particular, flank alopecia and pruritus. Based on medical the history, clinical evidence, and histopathological examination, color dilution alopecia was diagnosed. The dog was with oral melatonin treated for 3 months without success.

  11. Does the dilution effect generally occur in animal diseases?

    NARCIS (Netherlands)

    Huang, Zheng Y.X.; Yu, Yang; Langevelde, Van Frank; Boer, De Willem F.

    2017-01-01

    The dilution effect (DE) has been reported in many diseases, but its generality is still highly disputed. Most current criticisms of DE are related to animal diseases. Particularly, some critical studies argued that DE is less likely to occur in complex environments. Here our meta-analyses

  12. Inhibition Effect of Deanol on Mild Steel Corrosion in Dilute ...

    African Journals Online (AJOL)

    The influence of deanol on the corrosion behaviour of mild steel in dilute sulphuric acid with sodium chloride addition was studied by means of mass-loss, potentiodynamic polarization, electrode potential monitoring, scanning electron microscopy and statistical analysis. Results show that deanol performed excellently with ...

  13. Novel understanding of calcium silicate hydrate from dilute hydration

    KAUST Repository

    Zhang, Lina; Yamauchi, Kazuo; Li, Zongjin; Zhang, Xixiang; Ma, Hongyan; Ge, Shenguang

    2017-01-01

    The perspective of calcium silicate hydrate (C-S-H) is still confronting various debates due to its intrinsic complicated structure and properties after decades of studies. In this study, hydration at dilute suspension of w/s equaling to 10

  14. Estimation of Optimum Dilution in the GMAW Process Using Integrated ANN-GA

    Directory of Open Access Journals (Sweden)

    P. Sreeraj

    2013-01-01

    Full Text Available To improve the corrosion resistant properties of carbon steel, usually cladding process is used. It is a process of depositing a thick layer of corrosion resistant material over carbon steel plate. Most of the engineering applications require high strength and corrosion resistant materials for long-term reliability and performance. By cladding these properties can be achieved with minimum cost. The main problem faced on cladding is the selection of optimum combinations of process parameters for achieving quality clad and hence good clad bead geometry. This paper highlights an experimental study to optimize various input process parameters (welding current, welding speed, gun angle, and contact tip to work distance and pinch to get optimum dilution in stainless steel cladding of low carbon structural steel plates using gas metal arc welding (GMAW. Experiments were conducted based on central composite rotatable design with full replication technique, and mathematical models were developed using multiple regression method. The developed models have been checked for adequacy and significance. In this study, artificial neural network (ANN and genetic algorithm (GA techniques were integrated and labeled as integrated ANN-GA to estimate optimal process parameters in GMAW to get optimum dilution.

  15. Determination of the interchangeable heavy-metal fraction in soils by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Gaebler, H.E.; Bahr, A.; Mieke, B.

    1999-01-01

    An isotope dilution technique using enriched stable isotopes is applied to determine the interchangeable heavy-metal fraction in soils. Metals in two soil samples are extracted at constant pH, with water, NH 4 NO 3 , and EDTA. A spike of enriched stable isotopes is added to the suspension of sample and eluant at the beginning of the extraction. The heavy-metal fraction which exchanges with the added spike during the extraction is called the interchangeable fraction. The extractable heavy-metal fractions are obtained from the heavy-metal concentrations in the eluates. Isotope ratios and concentrations are determined by HR-ICP-MS. The isotope dilution technique described enables both the extractable and the interchangeable heavy-metal fractions to be determined in the same experiment. The combination of both results gives additional information on elemental availability under different conditions that cannot be obtained by analyzing the extractable heavy-metal fractions alone. It is demonstrated that in some cases different eluants just shift the distribution of the interchangeable fraction of an element between the solid and liquid phases (e.g., Pb and Cd in a topsoil sample) while the amount of the interchangeable fraction itself remains constant. For other elements, as Ni, Zn, and Cr, the use of different eluants (different pH, complexing agents) sometimes enlarges the interchangeable fraction. (orig.)

  16. Time-resolved optically-detected magnetic resonance of II-VI diluted-magnetic-semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V.Yu.; Karczewski, G. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Godlewski, M. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Dept. Mathem. and Natural Sci. College of Sci., Card. S. Wyszynski Univ., Warsaw (Poland); Yakovlev, D.R. [Experimental Physics 2, University of Dortmund, 44221 Dortmund (Germany); A. F. Ioffe Physico-Technical Institute, 194017 St. Petersburg (Russian Federation); Ryabchenko, S.M. [Institute of Physics NAS Ukraine, 03028 Kiev (Ukraine); Waag, A. [Institute of Semiconductor Technology, Braunschweig Technical University, 38106 Braunschweig (Germany)

    2007-01-15

    Time-resolved optically-detected magnetic resonance (ODMR) technique was used to study spin dynamics of Mn{sup 2+} ions in (Zn,Mn)Se- and (Cd,Mn)Te-based diluted magnetic semiconductor quantum wells. Times of spin-lattice relaxation have been measured directly from a dynamical shift of exciton luminescence lines after a pulsed impact of 60 GHz microwave radiation. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Charged particle detectors based on high quality amorphous silicon deposited with hydrogen or helium dilution of silane

    International Nuclear Information System (INIS)

    Hong, Wan-Shick; Drewery, J.S.; Jing, Tao; Lee, Hyoung-Koo; Kaplan, S.N.; Perez-Mendez, V.; Mireshghi, Ali; Kitsuno, Yu

    1994-11-01

    Electrical transport properties of the authors PECVD a-Si:H material has been improved by using hydrogen and/or helium dilution of silane and lower substrate temperature for deposition. For hydrogen-diluted material they have measured electron and hole mobilities ∼ 4 times larger, and μτ values 2-3 times higher than for their standard a-Si:H. The density of ionized dangling bonds (N D *) also showed a factor of 5-10 improvement. Due to its higher conductivity, the improved a- Si:H material is more suitable than conventional a-Si:H for TFT applications. However, it is difficult to make thick layers by H-dilution because of high internal stress. On the other hand, thick detectors can be made at a faster rate and lower stress by low temperature deposition with He-dilution and subsequent annealing. The internal stress, which causes substrate bending and delamination, was reduced by a factor of 4 to ∼90 MPa, while the electronic quality was kept as good as that of the standard material. By this technique 35 μm-thick n-i-p diodes were made without significant substrate bending, and the electronic properties, such as electron mobility and ionized dangling bond density, were suitable for detecting minimum ionizing particles

  18. Charged particle detectors based on high quality amorphous silicon deposited with hydrogen or helium dilution of silane

    International Nuclear Information System (INIS)

    Hong, W.S.; Drewery, J.S.; Jing, T.; Lee, H.; Kaplan, S.N.; Perez-Mendez, V.; Kitsuno, Y.

    1995-01-01

    Electrical transport properties of the PECVD a-Si:H material has been improved by using hydrogen and/or helium dilution of silane and lower substrate temperature for deposition. For hydrogen-diluted material the authors measured electron and hole mobilities ∼4 times larger, and microτ values 2--3 times higher than for the standard a-Si:H. The density of ionized dangling bonds (N D *) also showed a factor of 5--10 improvement. Due to its higher conductivity, the improved a-Si:H material is more suitable than conventional a-Si:H for TFT applications. However, it is difficult to make thick layers by H-dilution because of high internal stress. On the other hand, thick detectors can be made at a faster rate and lower stress by low temperature deposition with He-dilution and subsequent annealing. The internal stress, which causes substrate bending and delamination, was reduced by a factor of 4 to ∼90 MPa, while the electronic quality was kept as good as that of the standard material. By this technique 35 microm-thick n-i-p diodes were made without significant substrate bending, and the electronic properties, such as electron mobility and ionized dangling bond density, were suitable for detecting minimum ionizing particles

  19. Improving the Efficiency of 3-D Hydrogeological Mixers: Dilution Enhancement Via Coupled Engineering-Induced Transient Flows and Spatial Heterogeneity

    Science.gov (United States)

    Di Dato, Mariaines; de Barros, Felipe P. J.; Fiori, Aldo; Bellin, Alberto

    2018-03-01

    Natural attenuation and in situ oxidation are commonly considered as low-cost alternatives to ex situ remediation. The efficiency of such remediation techniques is hindered by difficulties in obtaining good dilution and mixing of the contaminant, in particular if the plume deformation is physically constrained by an array of wells, which serves as a containment system. In that case, dilution may be enhanced by inducing an engineered sequence of injections and extractions from such pumping system, which also works as a hydraulic barrier. This way, the aquifer acts as a natural mixer, in a manner similar to the industrialized engineered mixers. Improving the efficiency of hydrogeological mixers is a challenging task, owing to the need to use a 3-D setup while relieving the computational burden. Analytical solutions, though approximated, are a suitable and efficient tool to seek the optimum solution among all possible flow configurations. Here we develop a novel physically based model to demonstrate how the combined spatiotemporal fluctuations of the water fluxes control solute trajectories and residence time distributions and therefore, the effectiveness of contaminant plume dilution and mixing. Our results show how external forcing configurations are capable of inducing distinct time-varying groundwater flow patterns which will yield different solute dilution rates.

  20. Sugar yields from dilute oxalic acid pretreatment of maple wood compared to those with other dilute acids and hot water.

    Science.gov (United States)

    Zhang, Taiying; Kumar, Rajeev; Wyman, Charles E

    2013-01-30

    Dilute oxalic acid pretreatment was applied to maple wood to improve compatibility with downstream operations, and its performance in pretreatment and subsequent enzymatic hydrolysis was compared to results for hydrothermal and dilute hydrochloric and sulfuric acid pretreatments. The highest total xylose yield of ∼84% of the theoretical maximum was for both 0.5% oxalic and sulfuric acid pretreatment at 160 °C, compared to ∼81% yield for hydrothermal pretreatment at 200 °C and for 0.5% hydrochloric acid pretreatment at 140 °C. The xylooligomer fraction from dilute oxalic acid pretreatment was only 6.3% of the total xylose in solution, similar to results with dilute hydrochloric and sulfuric acids but much lower than the ∼70% value for hydrothermal pretreatment. Combining any of the four pretreatments with enzymatic hydrolysis with 60 FPU cellulase/g of glucan plus xylan in the pretreated maple wood resulted in virtually the same total glucose plus xylose yields of ∼85% of the maximum possible. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Improvement of sample preparation for input plutonium accountability measurement by isotope dilution gammy-ray spectroscopy

    International Nuclear Information System (INIS)

    Nishida, K.; Kuno, Y.; Sato, S.; Masui, J.; Li, T.K.; Parker, J.L.; Hakkila, E.A.

    1992-01-01

    The sample preparation method for the isotope dilution gamma-ray spectrometry (IDGS) technique has been further improved for simultaneously determining the plutonium concentration and isotopic composition of highly irradiated spent-fuel dissolver solutions. The improvement includes using ion-exchange filter papers (instead of resin beads, as in two previous experiments) for better separation and recovery of plutonium from fission products. The results of IDGS measurements for five dissolver solutions are in good agreement with those by mass spectrometry with ∼0.4% for plutonium concentration and ∼0.1% for 239 Pu isotopic composition. The precision of the plutonium concentration is ∼1% with a 1-h count time. The technique could be implemented as an alternative method for input accountability and verification measurements in reprocessing plants

  2. Evaluation of method for phthalate extraction from milk related to milk dilution ratio

    Directory of Open Access Journals (Sweden)

    Milojković Danica S.

    2015-01-01

    Full Text Available Liquid-liquid extraction techniques were compared coupled with gas chromatography-mass spectrometry (GC-MS, for the extraction and the determination of four phthalates: dimethyl phthalate (DMP, di-n-butyl phthalate (DBP, benzyl butyl phthalate (BBP and di-(2-ethylhexyl phthalate (DEHP in six different kinds of milk-based samples. Extraction factors: sample preparation, organic solvent type and volume, salt effect, agitation and the extraction time were optimized. The ion of base peaks (m/z 149 for DBP, BBP and DEHP and m/z 163 for DMP for investigated phthalates were selected for the screening studies. The acquisition was performed at the selected ion monitoring mode. The MSD response for GC-MS phthalate calibration standards was linear between 0.25 and 2.50 μg mL-1 with calculated LODs between 0.01 μg mL-1 to 0.04 μg mL-1 and LOQs of 0.05 μg mL-1 to 0.12 μg mL-1, while repeatability was between 1.7 % to 4.9 % RSD. The study demonstrated an increase of the recovery of less polar phthalates in matrix milk standards by matrix dilution. Recovery for hydrophilic phthalates, like DMP, was not changed by matrix dilution and it was continuously low for the investigated method. Two spiking levels were tested for influence of matrix dilution on phthalate recovery, showed the same trend. [Projekat Ministarstva nauke Republike Srbije, br. 31060

  3. Husimi-cactus approximation study on the diluted spin ice

    Science.gov (United States)

    Otsuka, Hiromi; Okabe, Yutaka; Nefedev, Konstantin

    2018-04-01

    We investigate dilution effects on the classical spin-ice materials such as Ho2Ti2O7 and Dy2Ti2O7 . In particular, we derive a formula of the thermodynamic quantities as functions of the temperature and a nonmagnetic ion concentration based on a Husimi-cactus approximation. We find that the formula predicts a dilution-induced crossover from the cooperative to the conventional paramagnets in a ground state, and that it also reproduces the "generalized Pauling's entropy" given by Ke et al. To verify the formula from a numerical viewpoint, we compare these results with Monte Carlo simulation calculation data, and then find good agreement for all parameter values.

  4. Properties of magnetically diluted nanocrystals prepared by mechanochemical route

    International Nuclear Information System (INIS)

    Balaz, P.; Skorvanek, I.; Fabian, M.; Kovac, J.; Steinbach, F.; Feldhoff, A.; Sepelak, V.; Jiang, J.; Satka, A.; Kovac, J.

    2010-01-01

    The bulk and surface properties of magnetically diluted Cd 0.6 Mn 0.4 S nanocrystals synthesized by solid state route in a planetary mill were studied. XRD, SEM, TEM (HRTEM), low-temperature N 2 sorption, nanoparticle size distribution as well as SQUID magnetometry methods have been applied. The measurements identified the aggregates of small nanocrystals, 5-10 nm in size. The homogeneity of produced particles with well developed specific surface area (15-66 m 2 g -1 ) was documented. The transition from the paramagnetic to the spin-glass-like phase has been observed below ∼40 K. The changes in the magnetic behaviour at low temperatures seem to be correlated with the formation of the new surface area as a consequence of milling. The magnetically diluted Cd 0.6 Mn 0.4 S nanocrystals are obtained in the simple synthesis step, making the process attractive for industrial applications.

  5. Sibship Size and Gendered Resource Dilution in Different Societal Contexts.

    Directory of Open Access Journals (Sweden)

    Matthijs Kalmijn

    Full Text Available Resource dilution theory hypothesizes that children's educational attainment suffers from being raised with many siblings, as the parental resources have to be shared with more children. Based on economic and cultural theories, we hypothesize that resource dilution is gendered: especially a larger number of brothers is harmful to a person's educational attainment. Using the Survey of Health, Ageing and Retirement in Europe, covering 18 European countries, we show that the number of brothers is more negatively related with the odds of obtaining a college degree than the number of sisters. This holds particularly for women. However, this pattern is weaker in countries that are known to have a more gender-egalitarian climate.

  6. The development and site investigation of fume diluter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bok Youn; Kang, Chang Hee; Jo, Young Do; Lim, Sang Taek [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    It is third project year on `Application of mobile diesel equipment in underground mines` for providing appropriate measures to improve underground working environment contaminated by the diesel exhaust pollutants. For reducing the exhaust temperature bellow 70 deg. C to prevent production of the governing pollutant (NO{sub 2}), the fume diluter is verified the most effective device through the site investigation. Therefore, the fume diluter is strongly recommended instead of catalytic converter which is employed presently. The performances derived from the tests are as follows; 1) This device increased air flow to 6.7-8.4 times of the original exhaust, 2) Exhaust temperature can be reduced to 66 deg. C from 161 deg. C, 3) All the pollutants can be reduced to bellow than 30 % of exhaust concentration, 4) This device requires less cost and no maintenance. (author). 4 tabs., 4 figs.

  7. Critical mass variation of 239Pu with water dilution

    International Nuclear Information System (INIS)

    Pearlstein, S.

    1996-01-01

    The critical mass of an unreflected solid sphere of 239 Pu is ∼ 10 kg. The increase in critical mass observed for small water dilutions of unreflected 239 Pu spheres is paradoxical. Introducing small amounts of water uniformly throughout the sphere increases the spherical volume containing the same amount of 239 Pu as the critical solid sphere. The increase in radius decreases the surface-to-volume ratio of the sphere, which has the effect to first order of decreasing the neutron leakage, which is proportional to the surface, relative to the fissions, which are proportional to the volume. The reduction in neutron leakage is expected to reduce the critical mass, but instead, the critical mass is observed to increase. It is discussed how changes in the fast neutron spectrum with corresponding changes in the nuclear parameters result in an increase in critical mass for small water dilutions

  8. Percolation of polyatomic species on site diluted lattices

    International Nuclear Information System (INIS)

    Cornette, V.; Ramirez-Pastor, A.J.; Nieto, F.

    2006-01-01

    In this Letter, the percolation of (a) linear segments of size k and (b) k-mers (particles occupying k adjacent sites) of different structures and forms deposited on a diluted square lattice have been studied. The diluted lattice is built by randomly selecting a fraction of sites which are considered forbidden for deposition. The analysis of the obtained results is made in the framework of the finite size scaling theory. The characteristic parameters of the percolation problem are dependent not only on the form and structure of the k-mers but also on the properties of the lattice where they are deposited. A phase diagram separating a percolating from a non-percolating region is determined and discussed

  9. Exchange bias in diluted-antiferromagnet/antiferromagnet bilayers

    International Nuclear Information System (INIS)

    Mao, Zhongquan; Zhan, Xiaozhi; Chen, Xi

    2015-01-01

    The hysteresis-loop properties of a diluted-antiferromagnetic (DAF) layer exchange coupling to an antiferromagnetic (AF) layer are investigated by means of numerical simulations. Remarkable loop shift and coercivity enhancement are observed in such DAF/AF bilayers, while they are absent in the uncoupled DAF single layer. The influences of pinned domains, dilution, cooling field and DAF layer thickness on the loop shift are investigated systematically. The result unambiguously confirms an exchange bias (EB) effect in the DAF/AF bilayers. It also reveals that the EB effect originates from the pinned AF domains within the DAF layer. In contrast to conventional EB systems, frozen uncompensated spins are not found at the interface of the AF pinning layer. (paper)

  10. A model for the viscosity of dilute smectite gels

    International Nuclear Information System (INIS)

    Liu, L.

    2011-01-01

    A simple yet accurate model describing the viscosity of dilute suspensions of sodium montmorillonite in dilute homo-ionic solutions is presented. Taking the clay particle and the surrounding clouds of ions as a whole as an uncharged but soft, coin-like particle, the Huggins' equation for a suspension of uncharged particles is extended in the model to account for not only the primary and the secondary electro-viscous effects, but also the multi-particle interaction. The agreements between the predicted and measured results are excellent. The Huggins' coefficient obtained compares favorably with available data, while the intrinsic viscosity reduces to the Simha's equation in the large limit of ionic strength, suggesting that the model is robust. (authors)

  11. Novel Dilute Bismide, Epitaxy, Physical Properties and Device Application

    Directory of Open Access Journals (Sweden)

    Lijuan Wang

    2017-02-01

    Full Text Available Dilute bismide in which a small amount of bismuth is incorporated to host III-Vs is the least studied III-V compound semiconductor and has received steadily increasing attention since 2000. In this paper, we review theoretical predictions of physical properties of bismide alloys, epitaxial growth of bismide thin films and nanostructures, surface, structural, electric, transport and optic properties of various binaries and bismide alloys, and device applications.

  12. Electron pairing in dilute liquid metal-metal halide solutions

    Energy Technology Data Exchange (ETDEWEB)

    Selloni, A.; Car, R.; Parrinello, M.; Carnevali, P.

    1987-09-10

    Spin density functional theory is used to describe the interaction between solvated electrons in KCl in the high dilution limit. In agreement with recent calculations based on the path integral method our results for antiparallel spin predict a strong tendency to form localized bielectronic complexes. At variance with numerical path integral, our method can efficiently treat the case of parallel spins. For this case we find that electrons repel each other and localize into separate F-center-like states.

  13. Electron paramagnetic resonance studies of defects in dilute magnetic alloys

    International Nuclear Information System (INIS)

    Suss, J.T.; Raizman, A.

    1980-01-01

    The EPR spectrum of erbium was used to study the effects of cold-working (rolling and mechanical polishing) in dilute gold-erbium alloys. Variation in the EPR linewidth, intensity and asymmetry parameter (A/B ratio) were investigated. Most of the results could be interpreted in terms of segregation of erbium ions to subgrain boundaries (dislocations) in a surface layer of a few thousand Angstroms. (author)

  14. Water Stress Scatters Nitrogen Dilution Curves in Wheat

    Directory of Open Access Journals (Sweden)

    Marianne Hoogmoed

    2018-04-01

    Full Text Available Nitrogen dilution curves relate a crop’s critical nitrogen concentration (%Nc to biomass (W according to the allometric model %Nc = a W-b. This model has a strong theoretical foundation, and parameters a and b show little variation for well-watered crops. Here we explore the robustness of this model for water stressed crops. We established experiments to examine the combined effects of water stress, phenology, partitioning of biomass, and water-soluble carbohydrates (WSC, as driven by environment and variety, on the %Nc of wheat crops. We compared models where %Nc was plotted against biomass, growth stage and thermal time. The models were similarly scattered. Residuals of the %Nc - biomass model at anthesis were positively related to biomass, stem:biomass ratio, Δ13C and water supply, and negatively related to ear:biomass ratio and concentration of WSC. These are physiologically meaningful associations explaining the scatter of biomass-based dilution curves. Residuals of the thermal time model showed less consistent associations with these variables. The biomass dilution model developed for well-watered crops overestimates nitrogen deficiency of water-stressed crops, and a biomass-based model is conceptually more justified than developmental models. This has implications for diagnostic and modeling. As theory is lagging, a greater degree of empiricism might be useful to capture environmental, chiefly water, and genotype-dependent traits in the determination of critical nitrogen for diagnostic purposes. Sensitivity analysis would help to decide if scaling nitrogen dilution curves for crop water status, and genotype-dependent parameters are needed.

  15. Thermomechanical Processing of Structural Steels with Dilute Niobium Additions

    Science.gov (United States)

    Cui, Z.; Patel, J.; Palmiere, E. J.

    The recrystallisation behaviour of medium carbon steels with dilute Nb addition was investigated by means of plane strain compression tests and the observation of prior austenite microstructures during different deformation conditions. It was found that complete suppression of recrystallisation did not occur in the deformation temperature range investigated. At lower deformation temperatures, partial recrystallisation occurred in the higher Nb sample. This gives the potential to obtain a full suppression of recrystallisation at lower deformation temperatures.

  16. Removal of sulfite liquor from digesters with partially diluted liquor

    Energy Technology Data Exchange (ETDEWEB)

    Leshchenko, I G; Sykol, V P

    1957-01-01

    The yield of reducing sugars was raised from 189 to 224 kg/ton of pulp by displacing the cooking liquor with diluted liquor. As the pressure during blow-off dropped to 3.5-3.0 atmosphere, weak sulfite liquor was added at the rate 120 cu m/hr. After 5-10 minutes the liquor was pumped from the digester to the ethanol plant.

  17. Learning and forgetting on asymmetric, diluted neural networks

    International Nuclear Information System (INIS)

    Derrida, B.; Nadal, J.P.

    1987-01-01

    It is possible to construct diluted asymmetric models of neural networks for which the dynamics can be calculated exactly. The authors test several learning schemes, in particular, models for which the values of the synapses remain bounded and depend on the history. Our analytical results on the relative efficiencies of the various learning schemes are qualitatively similar to the corresponding ones obtained numerically on fully connected symmetric networks

  18. Regional lung deposition of aged and diluted sidestream tobacco smoke

    International Nuclear Information System (INIS)

    Hofmann, W; Winkler-Heil, R; McAughey, J

    2009-01-01

    Since aged and diluted smoke particles are in general smaller and more stable than mainstream tobacco smoke, it should be possible to model their deposition on the basis of their measured particle diameters. However in practice, measured deposition values are consistently greater than those predicted by deposition models. Thus the primary objective of this study was to compare theoretical predictions obtained by the Monte Carlo code IDEAL with two human deposition studies to attempt to reconcile these differences. In the first study, male and female volunteers inhaled aged and diluted sidestream tobacco smoke at two steady-state concentrations under normal tidal breathing conditions. In the second study, male volunteers inhaled aged and diluted sidestream smoke labelled with 212 Pb to fixed inhalation patterns. Median particle diameters in the two studies were 125 nm (CMD) and 210 nm (AMD), respectively. Experimental data on total deposition were consistently higher than the corresponding theoretical predictions, exhibiting significant inter-subject variations. However, measured and calculated regional deposition data are quite similar to each other, except for the extra-thoracic region. This discrepancy suggests that either the initial particle diameter decreases upon inspiration and/or additional deposition mechanisms are operating in the case of tobacco smoke particles.

  19. Novel aspects of diluted and digital magnetic heterostructures

    International Nuclear Information System (INIS)

    Bonanni, A.

    1999-04-01

    In the present work novel aspects of diluted and digital II-VI-based heterostructures containing Mn ions are investigated. All the structures under study were fabricated by means of molecular beam epitaxy. Digital magnetic heterostructures have been prepared by incorporating discrete (sub)monolayers of the purely magnetic semiconductor MnTe into otherwise non magnetic CdTe quantum wells embedded in CdMgTe barriers. Formation and binding energy of magnetic polarons have been investigated in these structures and compared with the diluted case. Reflectance difference spectroscopy (RDS) performed ex-situ allowed to distinguish between signals due to the crystal anisotropy solely and those induced by the presence a magnetic elements. The problem of p-type doping of bulk diluted magnetic semiconductors II-VI-based is tackled. During and upon growth of ZnMnTe highly doped with N, in-situ RDS was carried out in order to investigate intra-ion transitions within the half filled 3d shell of Mn. Transport measurements and magnetometry at low temperature were performed to study, on the tracks of recent theoretical works, the influence of free carriers on the interaction between magnetic ions. As expected, indications of ferromagnetic ordering were found for the DMS with the highest concentration of carriers. Special attention was given to the formation of Mn islands on a II-VI substrate and to their change in morphology upon overgrowth with a mismatched material. A rich zoology of regularly shaped nanostructures could be produced. (author)

  20. Pollutant Dilution and Diffusion in Urban Street Canyon Neighboring Streets

    Science.gov (United States)

    Sun, Z.; Fu, Zh. M.

    2011-09-01

    In the present study we investigated the airflow patterns and air quality of a series of typical street canyon combinations, developed a mass balance model to determine the local pollutant dilution rate, and discuss the impact of upstream canyon on the air quality of downstream canyon. The results indicated that the geometrical size of upstream and downstream buildings have significant impacts on the ambient airflow patterns. The pollution distribution within the canyons varies with different building combinations and flow patterns. Within the upstream canyon, pollution always accumulates to the low building side for non-symmetrical canyon, and for symmetrical canyon high level of pollution occurs at the leeward side. The height of the middle and downstream buildings can evidently change the pollutant dispersion direction during the transport process. Within the polluted canyon, the pollutant dilution rate (PDR) also varies with different street canyon combinations. The highest PDR is observed when the upstream buildings are both low buildings no matter the height of downstream building. However, the two cases are likely to contribution pollution to the downstream canyon. The H-L-H combination is mostly against local pollution remove, while the L-H-L case is considered the best optimistic building combination with both the ability of diluting local pollution and not remarkably decreasing air quality of downstream canyon. The current work is expected instructive for city designers to optimize traffic patterns under typical existing geometry or in the development of urban geometry modification for air quality control.

  1. The issue of risk dilution in risk assessments

    International Nuclear Information System (INIS)

    Wilmot, R.; Robinson, P.

    2004-01-01

    This paper explores an issue that was first highlighted more than 20 years ago during an inquiry concerning the Sizeweli B nuclear power station in the UK. In the probabilistic safety assessment for this plant, the proponent had apparently reduced its estimates of risk by admitting to increased uncertainty about the timing of certain events. This situation is counter-intuitive, since an increase in uncertainty about the factors contributing to safety would be expected to lead to less confidence and hence to greater risk. This paradoxical situation was termed 'risk dilution' and it has been a topic of interest to reviewers of safety cases since. The recent international peer review of the Yucca Mountain performance assessments concluded that there was a potential for risk dilution in the assumptions and calculations presented. The next section describes how assumptions about the timing of events and other aspects of an assessment may lead to risk dilution, and this is followed by two examples based on recent performance assessments. The final section discusses how potential problems can be identified in safety cases, and the types of response that a regulator might adopt as a result. (authors)

  2. Physical modelling of a rapid boron dilution transient

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G.; Hemstroem, B.; Karlsson, R. [Vattenfall Utveckling AB, Aelvkarleby (Sweden); Jacobson, S. [Vattenfall AB, Ringhals, Vaeroebacka (Sweden)

    1995-09-01

    The analysis of boron dilution accidents in pressurised water reactors has traditionally assumed that mixing is instantaneous and complete everywhere, eliminating in this way the possibility of concentration inhomogeneities. Situations can nevertheless arise where a volume of coolant with a low boron concentration may eventually enter the core and generate a severe reactivity transient. The work presented in this paper deals with a category of Rapid Boron Dilution Events characterised by a rapid start of a Reactor Coolant Pump (RCP) with a plug of relatively unborated water present in the RCS pipe. Model tests have been made at Vattenfall Utveckling AB in a simplified 1:5 scale model of a Westinghouse PWR. Conductivity measurements are used to determine dimensionless boron concentration. The main purpose of this experimental work is to define an experimental benchmark against which a mathematical model can be tested. The final goal is to be able to numerically predict Boron Dilution Transients. This work has been performed as a part of a Co-operative Agreement with Electricite` de France (EDF).

  3. The Dilution Effect and Information Integration in Perceptual Decision Making.

    Directory of Open Access Journals (Sweden)

    Jared M Hotaling

    Full Text Available In cognitive science there is a seeming paradox: On the one hand, studies of human judgment and decision making have repeatedly shown that people systematically violate optimal behavior when integrating information from multiple sources. On the other hand, optimal models, often Bayesian, have been successful at accounting for information integration in fields such as categorization, memory, and perception. This apparent conflict could be due, in part, to different materials and designs that lead to differences in the nature of processing. Stimuli that require controlled integration of information, such as the quantitative or linguistic information (commonly found in judgment studies, may lead to suboptimal performance. In contrast, perceptual stimuli may lend themselves to automatic processing, resulting in integration that is closer to optimal. We tested this hypothesis with an experiment in which participants categorized faces based on resemblance to a family patriarch. The amount of evidence contained in the top and bottom halves of each test face was independently manipulated. These data allow us to investigate a canonical example of sub-optimal information integration from the judgment and decision making literature, the dilution effect. Splitting the top and bottom halves of a face, a manipulation meant to encourage controlled integration of information, produced farther from optimal behavior and larger dilution effects. The Multi-component Information Accumulation model, a hybrid optimal/averaging model of information integration, successfully accounts for key accuracy, response time, and dilution effects.

  4. The Dilution Effect and Information Integration in Perceptual Decision Making.

    Science.gov (United States)

    Hotaling, Jared M; Cohen, Andrew L; Shiffrin, Richard M; Busemeyer, Jerome R

    2015-01-01

    In cognitive science there is a seeming paradox: On the one hand, studies of human judgment and decision making have repeatedly shown that people systematically violate optimal behavior when integrating information from multiple sources. On the other hand, optimal models, often Bayesian, have been successful at accounting for information integration in fields such as categorization, memory, and perception. This apparent conflict could be due, in part, to different materials and designs that lead to differences in the nature of processing. Stimuli that require controlled integration of information, such as the quantitative or linguistic information (commonly found in judgment studies), may lead to suboptimal performance. In contrast, perceptual stimuli may lend themselves to automatic processing, resulting in integration that is closer to optimal. We tested this hypothesis with an experiment in which participants categorized faces based on resemblance to a family patriarch. The amount of evidence contained in the top and bottom halves of each test face was independently manipulated. These data allow us to investigate a canonical example of sub-optimal information integration from the judgment and decision making literature, the dilution effect. Splitting the top and bottom halves of a face, a manipulation meant to encourage controlled integration of information, produced farther from optimal behavior and larger dilution effects. The Multi-component Information Accumulation model, a hybrid optimal/averaging model of information integration, successfully accounts for key accuracy, response time, and dilution effects.

  5. Infinitely dilute partial molar properties of proteins from computer simulation.

    Science.gov (United States)

    Ploetz, Elizabeth A; Smith, Paul E

    2014-11-13

    A detailed understanding of temperature and pressure effects on an infinitely dilute protein's conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method's feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages.

  6. On the nitrogen isotope dilution analysis by means of the automated NA-5A type 15N-analyzer

    International Nuclear Information System (INIS)

    Faust, H.; Mueller, G.; Stoerl, H.J.

    1976-01-01

    The analytical conditions are investigated under which quantitative nitrogen determination through isotope dilution analysis is possible using the NA-5A type 15 N-analyzer. Calculation of the nitrogen quantity, estimation of the maximum error and the evaluation technique are considered in detail. Test analyses performed on ammonia, urea, and amino acid nitrogen model solutions labelled in different ways yielded good correspondence with preset values. This technique was applied to determine the nitrogen content of biomedical materials. A working scheme for direct quantitative determination of ammonia-N, urea-N, and total-N in urine is presented. (author)

  7. Isolation and structural characterization of sugarcane bagasse lignin after dilute phosphoric acid plus steam explosion pretreatment and its effect on cellulose hydrolysis

    Science.gov (United States)

    Jijiao Zeng; Zhaohui Tong; Letian Wang; J.Y. Zhu; Lonnie Ingram

    2014-01-01

    The structure of lignin after dilute phosphoric acid plus steam explosion pretreatment process of sugarcane bagasse in a pilot scale and the effect of the lignin extracted by ethanol on subsequent cellulose hydrolysis were investigated. The lignin structural changes caused by pretreatment were identified using advanced nondestructive techniques such as gel permeation...

  8. Assessment of biofertigation of soybean using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Janat, M.; Kurdali, F.

    2005-01-01

    This study was carried out to evaluate the biofertigation, traditional inoculation under drip Fertigation and surface irrigation of soybean. The distribution of nitrogen fixed varied according to irrigation and inoculation method, where soybean grains were the major pool for atmospheric nitrogen and about 67% of this nitrogen was accumulated in the seeds of the drip-fertigated and biofertigated soybean, still under surface irrigation soybean seeds accumulated about 50% of the biologically fixed nitrogen. The results also showed that water-use efficiencies of bioferigated and drip-fertigated soybean and sorghum were much higher than those of surface-irrigated soybean and sorghum. The increase in WUE ranged between 70-40% for soybean and 90-77% for sorghum. (author)

  9. Phosphorus kinetics in ovine fed with different phosphorus sources, using the isotopic dilution technique

    International Nuclear Information System (INIS)

    Vitti, D.M.S.S.; Abdalla, A.L.; Meirelles, C.F.

    1992-01-01

    Phosphorus kinetics in fluids and tissues of sheep was studied. Sixteen castrated sheep were kept in metabolism cages, receiving a semipuried diet containing as phosphorus sources dicalcium phosphate (BIC), monoammonium phosphate (MAP), superphosphate (SPT) and Tapita phosphate (TAP) 200 μCi P-32 was intravenously injected in each sheep and blood and feces were collected for eight days. From the specific activities in feces and plasma the endogenous phosphorus and the absorption coefficient were calculated. plasma P-32 half-life was determined. Nine days after injection the animals were killed and liver, kidney and muscle and bone samples were collected. P-32 retention and specific activities in tissues were determined. Endogenous phosphorus and absorption coefficient values were 54.44 ± 15.31 mh/kg live weight and 0.60; 47.98 ± 12.44 and 0.56; 39.70 ± 7.29 and 0.49; 59.11 ± 17.12 and 0.58 respectively bor BIC, MAP, TAP and SPT. P-32 retention by tissues was 0.29 ± 0.09; 0.27 ± 0.06; 0.16 ± 0.04 and 0.08 ± 0.03 dose/g fresh matter, respectively for bone, liver, kidney and muscle. It was concluded that animals which received TAP showed differences in absorption, distribution and P-32 retention by fluids and tissues. Phosphorus availability was lower for this source. (author)

  10. Evaluation of the nutritive value of phosphate fertilizer using an isotopic dilution technique

    International Nuclear Information System (INIS)

    Guity, A.R.

    1979-01-01

    A new formulation of the Fried method is proposed in which the availability of the fertilizer phosphorus is directly compared with that of the Larsen phosphorus. A value G is defined representing the equivalent of the amount of P applied with the same availability as that of the Larsen phosphorus in the soil. During a pot experiment, the G values were determined for eight different Iranian soils. The fertilizer used was superphosphate, applied in the ratio of 11.52 mg P per kg of soil; rye-grass was chosen as test plant. The results obtained show that the G values vary between 11.94 and 45.16 mg P/kg. These values are 1.04-3.92 times greater than the quantity applied. The availability of the fertilizer employed is thus 1.04-3.92 times greater than that of the Larsen phosphorus. It can be seen from the L and G values that, in at least four or five soils, the amount applied is not enough to produce a significant increase in the size of the pool of phosphorus available to the plants, whereas in the less fertile soils the G values are equivalent to 61-82% of the quantity of Larsen phosphorus. A statistical calculation shows that there are significant correlations between the G value of a soil and the quantity of phosphorus in the plants which is derived from this soil, between the G value and the quantity of phosphorus in plants derived from the fertilizer applied, and finally between the L+G value of the soil and the total quantity of phosphorus in the plants. It follows from this that the G value can be regarded as a convenient criterion for determining fertilization procedures

  11. Assessment of biofertigation of soybean using 15N isotopic dilution technique

    International Nuclear Information System (INIS)

    Janat, M.; Kurdali, F.

    2004-04-01

    This study was carried out to evaluate the bio, traditional inoculation under drip fertigation and surface irrigation of soybean. The distribution of nitrogen fixed varied according to irrigation and inoculation method, where soybean grain were the major pool for atmospheric nitrogen and about 67% of this nitrogen was accumulated in the needs of the drip-fertigated and biofertigated soybean, still under surface irrigation soybean seeds accumulated about 50% of the biologically fixed nitrogen. The results also showed that water-use efficiencies of biofertigated and drip-fertigated soybean and sorghum were much higher than those of surface-irrigated soybean and sorghum. The increase in WUE ranged between 70-40% for soybean and 90-77% for sorghum. (author)

  12. Estimation of transcapillary transport of palmitate by the multiple indicator dilution technique

    International Nuclear Information System (INIS)

    Little, S.E.; van der Vusse, G.J.; Bassingthwaighte, J.B.

    1986-01-01

    From the outflow concentration-time curves for 14 C-palmitate, intravascular ( 131 I-albumin) and extracellular ( 3 H-sucrose) tracers, palmitate extraction was estimated in rabbit hearts Langendorff-perfused at a constant flow with nonrecirculated palmitate-albumin Kreb's Ringer buffer. Contamination of 131 I-albumin with free 13 $ 1 I - (typically 1%) or aggregated albumin (typically 0.1 to 0.5%) greatly alters the shapes of the tails of the curves after 2 albumin transit times, vitiating accurate estimation of cellular permeability or reactions. Buffers were prepared by adding K + -palmitate (made using K 2 CO 3 ) to albumin solutions. The final concentrations (after dialysing twice and filtering through a 1.2 μ filter) of K + , HCO 3 , and CO 3 were 5.0 mM, 23.5 mM and 0.5 mM respectively, pH was between 7.35 and 7.40 for several hours. The bolus of tracers was prepared by mixing 131 I-albumin (dialysed to remove I - , and filtered through a 0.2 μM filter to remove aggregates), K + [U- 14 C]palmitate (high specific activity) and 3 H-sucrose. Before injection the radioactive bolus is preequilibrated with the perfusate at bolus:perfusate ratio of 1:10. Glacial acetic acid is added to the outflow samples to remove the 14 CO 2 which, if present in the sample, would be interpreted as increased palmitate back diffusion. The peak extractions of palmitate were about 40% at perfusate palmitate concentrations of 0.02 to 1.0 mM, 0.4 mM albumin, at a flow of 5 mlg -1 2] 1 , showing capillary permeability-surface area product to be roughly constant. This suggests either than transcapillary palmitate transport is passive or that a transporter interacts with the albumin-palmitate complex

  13. Assessment of biofertigation of soybean using {sup 15}N isotopic dilution technique

    Energy Technology Data Exchange (ETDEWEB)

    Janat, M; Kurdali, F [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Agriculture

    2004-04-01

    This study was carried out to evaluate the bio, traditional inoculation under drip fertigation and surface irrigation of soybean. The distribution of nitrogen fixed varied according to irrigation and inoculation method, where soybean grain were the major pool for atmospheric nitrogen and about 67% of this nitrogen was accumulated in the needs of the drip-fertigated and biofertigated soybean, still under surface irrigation soybean seeds accumulated about 50% of the biologically fixed nitrogen. The results also showed that water-use efficiencies of biofertigated and drip-fertigated soybean and sorghum were much higher than those of surface-irrigated soybean and sorghum. The increase in WUE ranged between 70-40% for soybean and 90-77% for sorghum. (author)

  14. Single-borehole techniques

    International Nuclear Information System (INIS)

    Klotz, D.; Moser, H.; Trimborn, P.

    1978-01-01

    Proceeding on the theoretical considerations and on the experience and practice derived from laboratory and field testing, a system consisting of tracer injection units, detector units, measuring probe units and packers is presented, from which the different borehole probes required can be combined. A couple of examples of recent applications shows the position of the Single-Borehole Techniques with respect to the traditional methods used for the measurement of the ground-water flow. A confrontation of the permeabilities of different aquifers consents, both on the basis of the Single-Borehole Techniques as by pumping experiments, the determination of the reliability of the Point-Dilution-Method. The Point-Dilution-Method is giving information about the vertical and horizontal distribution of the permeabilities in an aquifer. By measuring the vertical current in two karst wells, the tributary horizons of a well have been determined, which gave valuable information for the subsequent well construction. Local leakages could be detected by measuring the vertical flow rate through observation wells arranged along a grout curtain erected on both sides of the retaining barrage of the Keban dam. (orig.) [de

  15. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material

    International Nuclear Information System (INIS)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-01-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound esposure time. Due to the complex matrix of this fly ash material, a two-steps purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs

  16. Effect of solute segregation on thermal creep in dilute nanocyrstalline Cu alloys

    International Nuclear Information System (INIS)

    Schäfer, Jonathan; Ashkenazy, Yinon; Albe, Karsten; Averback, Robert S

    2012-01-01

    Highlights: ► Segregating solutes lower the grain boundary free volume in nanocrystalline Cu. ► Lower free volume leads to reduced atomic mobility and higher creep resistance. ► Increase in creep resistance scales with atomic size of segregating solutes. ► Atomic processes in boundaries are similar to the ones in amorphous material. - Abstract: The effect of solute segregation on thermal creep in dilute nanocrystalline alloys (Cu–Nb, Cu–Fe, Cu–Zr) was studied at elevated temperatures using molecular dynamics simulations. A combined Monte-Carlo and molecular dynamics simulation technique was first used to equilibrate the distribution of segregating solutes. Then the creep rates of the diluted Cu samples were measured as functions of temperature, composition, load and accumulated strain. In Cu–Nb samples, the creep rates were observed to increase initially with strain, but then saturate at a value close to that obtained for alloys prepared by randomly locating the solute in the grain boundaries. This behavior is attributed to an increase in grain boundary volume and energy with added chemical disorder. At high temperatures, the apparent activation energy for creep was anomalously high, 3 eV, but only 0.3 eV at lower temperatures. This temperature dependence is found to correlate with atomic mobilities in bulk Cu–Nb glasses. Calculations of creep in nanocrystalline Cu alloys containing other solutes, Fe and Zr, show that the suppression of creep rate scales with their atomic volumes when dissolved in Cu.

  17. Opalescence in monoclonal antibody solutions and its correlation with intermolecular interactions in dilute and concentrated solutions.

    Science.gov (United States)

    Raut, Ashlesha S; Kalonia, Devendra S

    2015-04-01

    Opalescence indicates physical instability of a formulation because of the presence of aggregates or liquid-liquid phase separation in solution and has been reported for monoclonal antibody (mAb) formulations. Increased solution opalescence can be attributed to attractive protein-protein interactions (PPIs). Techniques including light scattering, AUC, or membrane osmometry are routinely employed to measure PPIs in dilute solutions, whereas opalescence is seen at relatively higher concentrations, where both long- and short-range forces contribute to overall PPIs. The mAb molecule studied here shows a unique property of high opalescence because of liquid-liquid phase separation. In this study, opalescence measurements are correlated to PPIs measured in diluted and concentrated solutions using light scattering (kD ) and high-frequency rheology (G'), respectively. Charges on the molecules were calculated using zeta potential measurements. Results indicate that high opalescence and phase separation are a result of the attractive interactions in solution; however, the presence of attractive interactions do not always imply phase separation. Temperature dependence of opalescence suggests that thermodynamic contribution to opalescence is significant and Tcloud can be utilized as a potential tool to assess attractive interactions in solution. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  18. Determination of zinc stable isotopes in biological materials using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Patterson, K.Y.; Veillon, Claude

    1992-01-01

    A method is described for using isotope dilution to determine both the amount of natural zinc and enriched isotopes of zinc in biological samples. Isotope dilution inductively coupled plasma mass spectrometry offers a way to quantify not only the natural zinc found in a sample but also the enriched isotope tracers of zinc. Accurate values for the enriched isotopes and natural zinc are obtained by adjusting the mass count rate data for measurable instrumental biases. Analytical interferences from the matrix are avoided by extracting the zinc from the sample matrix using diethylammonium diethyldithiocarbamate. The extraction technique separates the zinc from elements which form interfering molecular ions at the same nominal masses as the zinc isotopes. Accuracy of the method is verified using standard reference materials. The detection limit is 0.06 μg Zn per sample. Precision of the abundance ratios range from 0.3-0.8%. R.S.D. for natural zinc concentrations is about 200-600 μg g -1 . The accuracy and precision of the measurements make it possible to follow enriched isotopic tracers of zinc in biological samples in metabolic tracer studies. (author). 19 refs.; 1 fig., 4 tabs

  19. Dilution and slow injection reduces the incidence of rocuronium-induced withdrawal movements in children

    OpenAIRE

    Shin, Young Hee; Kim, Chung Su; Lee, Jong-Hwan; Sim, Woo Seog; Ko, Justin Sangwook; Cho, Hyun Sung; Jeong, Hui Yeon; Lee, Hye Won; Kim, Sang Hyun

    2011-01-01

    Background The aim of this study was to evaluate whether slow injection of diluted rocuronium could reduce rocuronium-induced withdrawal movements effectively in children. Methods After loss of consciousness, rocuronium 0.6 mg/kg was administered into 171 children according to the pre-assigned groups as follows: Group CF, injection of non-diluted rocuronium over 5 seconds; Group CS, injection of non-diluted rocuronium over 1 minute; Group DF, injection of diluted rocuronium (10 times) over 5 ...

  20. Crystal Fields in Dilute Rare-Earth Metals Obtained from Magnetization Measurements on Dilute Rare-Earth Alloys

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.

    1974-01-01

    Crystal field parameters of Tb, Dy, and Er in Sc, Y, and Lu are summarized. These parameters are obtained from magnetization measurements on dilute single crystals, and successfully checked by a number of different methods. The crystal field parameters vary unpredictably with the rare-earth solute....... B40, B60, and B66 are similar in Y and Lu. Crystal field parameters for the pure metals Tb, Dy, and Er are estimated from the crystal fields in Y and Lu....

  1. Theoretical investigation of the heavily-doped semiconductor aspect of ultra-dilute GaAsN

    Science.gov (United States)

    Sukpitak, Jessada; Sa-yakanit, Virulh

    2015-12-01

    The model of GaAs1- y N y ( y = 0.001) as a heavily-doped semiconductor in the ultra-dilute region is attentively examined. The model enables GaAsN to be viewed as a disordered assembly of three-dimensional quantum dots (potential wells) caused by random potential fluctuations from nitrogen pairs in the system. Consequently, Feynman's path-integration technique is applied in order to quantify the density of states (DOS) in the vicinity of the conduction band edge. The obtained DOS tail, even though overestimated, still clearly shows a much shorter tail than that the experimental result does. This shows that the heavily-doped semiconductor viewpoint is not proper for GaAsN, not even in the ultra-dilute region. Furthermore, this also suggests that the impurity wave function overlap is not a basic mechanism of band gap reduction.

  2. Quantification of root associated nitrogen fixation in kallar grass as estimated by sup/15/nitrogen isotope dilution

    International Nuclear Information System (INIS)

    Malik, K.A.; Zafar, Y.

    1985-01-01

    Present investigations were made by using sup/15/N isotope dilution technique to quantitatively estimate BNF in Kallar grass when grown under controlled conditions in nutrient solution and inoculated with N sub/2/-fixing bacteria. Azospirillum brasilense and two isolates from the rhizosphere of kallar grass were used as inoculant. After harvest acetylen reduction of roots, total yield, total N and sup/15/ N analysis were made. Total-N in inoculated treatments was 2-3 times higher than in control and so were the fresh and dry weight yields. The estimates based on isotopic dilution indicated that 50-70 percent N in the plant was derived from BNF in case of inoculated treatment. The results based on N balance gave relatively lower values of 40-60 percent of total N derived from fixation. The data revealed that in Kallar grass a substantial amount of plant N is derived from BNF. (orig./A.B.)

  3. Comparison of dilution factors for German wastewater treatment plant effluents in receiving streams to the fixed dilution factor from chemical risk assessment.

    Science.gov (United States)

    Link, Moritz; von der Ohe, Peter C; Voß, Katharina; Schäfer, Ralf B

    2017-11-15

    Incomplete removal during wastewater treatment leads to frequent detection of compounds such as pharmaceuticals and personal care products in municipal effluents. A fixed standard dilution factor of 10 for effluents entering receiving water bodies is used during the exposure assessment of several chemical risk assessments. However, the dilution potential of German receiving waters under low flow conditions is largely unknown and information is sparse for other European countries. We calculated dilution factors for two datasets differing in spatial extent and wastewater treatment plant (WWTP) size: a national dataset comprising 1225 large WWTPs in Central and Northern Germany and a federal dataset for 678 WWTPs of a single state in Southwest Germany. We found that the fixed factor approach overestimates the dilution potential of 60% and 40% of receiving waters in the national and the federal dataset, with median dilution factors of 5 and 14.5, respectively. Under mean flow conditions, 8% of calculated dilution factors were below 10, with a median dilution factor of 106. We also calculated regional dilution factors that accounted for effluent inputs from upstream WWTPs. For the national and the federal dataset, 70% and 60% of calculated regional dilution factors fell below 10 under mean low flow conditions, respectively. Decrease of regional dilution potential in small receiving streams was mainly driven by the next WWTP upstream with a 2.5 fold drop of median regional dilution factors. Our results show that using the standard dilution factor of 10 would result in the underestimation of environmental concentrations for authorised chemicals by a factor of 3-5 for about 10% of WWTPs, especially during low flow conditions. Consequently, measured environmental concentrations might exceed predicted environmental concentrations and ecological risks posed by effluents could be much higher, suggesting that a revision of current risk assessment practices may be required

  4. Elimination of slightly radioactive liquid effluent by dilution. Its consequences (1960); Elimination par dilution d'effluents liquides faiblement radioactifs. Leurs consequences (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Candillon, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Nuclear centres often have to solve problems raised by the elimination of large volumes of slightly radioactive liquid effluent. As things stand at present, the method usually adopted consists in expelling this effluent into the main water system in order to dilute it to a maximum, and thus to lower its radioactive isotope concentration to below the norms imposed by the Public Health Service. This technique requires systematic checking of the water system and its dependences, and demands a thorough knowledge of adsorption and fixation processes. (author) [French] Les centres nucleaires ont frequemment a resoudre des problemes poses par l'elimination de volumes importants d'effluents liquides faiblement radioactifs. Dans l'etat actuel des choses, la solution la plus utilisee consiste a rejeter ces effluents dans le reseau hydrographique de maniere a les diluer au maximum et abaisser ainsi leurs teneurs en isotopes radioactifs au-dessous des normes imposees par la Sante Publique. Cette technique necessite un controle systematique du reseau et de ses dependances et demande une connaissance approfondie des processus d'adsorption et de fixation. (auteur)

  5. Enhancement of the electrical characteristics of MOS capacitors by reducing the organic content of H2O-diluted Spin-On-Glass based oxides

    International Nuclear Information System (INIS)

    Molina, Joel; Munoz, Ana; Torres, Alfonso; Landa, Mauro; Alarcon, Pablo; Escobar, Manuel

    2011-01-01

    In this work, the physical, chemical and electrical properties of Metal-Oxide-Semiconductor (MOS) capacitors with Spin-On-Glass (SOG)-based thin films as gate dielectric have been investigated. Experiments of SOG diluted with two different solvents (2-propanol and deionized water) were done in order to reduce the viscosity of the SOG solution so that thinner films (down to ∼20 nm) could be obtained and their general characteristics compared. Thin films of SOG were deposited on silicon by the sol-gel technique and they were thermally annealed using conventional oxidation furnace and Rapid Thermal Processing (RTP) systems within N 2 ambient after deposition. SOG dilution using non-organic solvents like deionized water and further annealing (at relatively high temperatures ≥450 deg. C) are important processes intended to reduce the organic content of the films. Fourier-Transform Infrared (FTIR) Spectroscopy results have shown that water-diluted SOG films have a significant reduction in their organic content after increasing annealing temperature and/or dilution percentage when compared to those of undiluted SOG films. Both current-voltage (I-V) and capacitance-voltage (C-V) measurements show better electrical characteristics for SOG-films diluted in deionized water compared to those diluted in 2-propanol (which is an organic solvent). The electrical characteristics of H 2 O-diluted SOG thin films are very similar to those obtained from high quality thermal oxides so that their application as gate dielectrics in MOS devices is promising. Finally, it has been demonstrated that by reducing the organic content of SOG-based thin films, it is possible to obtain MOS devices with better electrical properties.

  6. Non-Markovian near-infrared Q branch of HCl diluted in liquid Ar.

    Science.gov (United States)

    Padilla, Antonio; Pérez, Justo

    2013-08-28

    By using a non-Markovian spectral theory based in the Kubo cumulant expansion technique, we have qualitatively studied the infrared Q branch observed in the fundamental absorption band of HCl diluted in liquid Ar. The statistical parameters of the anisotropic interaction present in this spectral theory were calculated by means of molecular dynamics techniques, and found that the values of the anisotropic correlation times are significantly greater (by a factor of two) than those previously obtained by fitting procedures or microscopic cell models. This fact is decisive for the observation in the theoretical spectral band of a central Q resonance which is absent in the abundant previous researches carried out with the usual theories based in Kubo cumulant expansion techniques. Although the theory used in this work only allows a qualitative study of the Q branch, we can employ it to study the unknown characteristics of the Q resonance which are difficult to obtain with the quantum simulation techniques recently developed. For example, in this study we have found that the Q branch is basically a non-Markovian (or memory) effect produced by the spectral line interferences, where the PR interferential profile basically determines the Q branch spectral shape. Furthermore, we have found that the Q resonance is principally generated by the first rotational states of the first two vibrational levels, those more affected by the action of the dissolvent.

  7. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    Science.gov (United States)

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  8. A radioactive tracer dilution method to determine the mass of molten salt

    International Nuclear Information System (INIS)

    Lei Cao; Jarrell, Josh; Hardtmayer, D.E.; White, Susan; Herminghuysen, Kevin; Kauffman, Andrew; Sanders, Jeff; Li, Shelly

    2017-01-01

    A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22 Na as a tracer was validated at bench scale. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined. (author)

  9. Mass spectrometric isotope dilution analyses of palladium, silver, cadmium and tellurium in carbonaceous chondrites

    International Nuclear Information System (INIS)

    Loss, R.D.; Rosman, K.J.R.; De Laeter, J.

    1984-01-01

    The mass spectrometric isotope dilution technique was used to measure the elemental abundances of Pd, Ag, Cd and Te in Orgueil (C1), Ivuna (C1), Murray (C2) and Allende (C3) chondrites. The Pd abundance of 554 ppb for the Cl chondrites is almost identical to the recommended value of Anders and Ebihara (1982); that for Cd (712 ppb) is approximately 5% higher, whereas that for Ag (198 ppb) is approximately 10% lower than the recommended values. A smooth distribution for the abundances of the odd-A nuclides between 65 128 Te and 130 Te to lie approximately 30% above the r-process peak at A = 130, whereas the new value fits smoothly into the general trend. (author)

  10. Mass spectrometic isotope dilution analysis of Am and Cm in spent fuels

    International Nuclear Information System (INIS)

    Wantschik, M.; Koch, L.; Commission of the European Communities, Karlsruhe; Ganser, B.

    1983-01-01

    Spent nuclear fuels contain Am and Cm in the 10 ppb to 100 ppm range. Because of this low abundance and the necessity of handling small samples of the highly toxic fuel material only a mass-spectrometric isotope dilution analysis can give sufficiently accurate results. Since suitable spikes and/or standards have been lacking, this method has not been applied. Using known masses (+- 0.1%) of Am-241 and Cm-244 metal, Am-243 and Cm-248 spikes were calibrated to an accuracy of better than 0.2%. The standards were reanalysed by chemical titration and several radiometric techniques. The chemical conditioning is based on ionexchange chromatography with alpha-hydroxyisobutyric acid. A sample size of 10 -7 g is sufficient. For the mass-spectrometric measurement 10 -9 g of the elements are required. The accuracy for the determination of the main isotope is 0.5%. (orig./BRB)

  11. Separation of glycols from dilute aqueous solutions via complexation with boronic acids

    Energy Technology Data Exchange (ETDEWEB)

    Randel, L.A.; King, C.J.

    1991-07-01

    This work examines methods of separating low molecular weight glycols from dilute aqueous solution. Extraction into conventional solvents is generally not economical, since, in the literature reviewed, distribution ratios for the two- to four-carbon glycols are all less than one. Distribution ratios can be increased, however, by incorporating into the organic phase an extracting agent that will complex with the solute of interest. The extracting agent investigated in this work is 3-nitrophenylboronic acid (NPBA). NPBA, a boric acid derivative, reversibly complexes with many glycols. The literature on complexation of borate and related compounds with glycols, including mechanistic data, measurement techniques, and applications to separation processes, provides information valuable for designing experiments with NPBA and is reviewed herein. 88 refs., 15 figs., 24 tabs.

  12. Development of isotope dilution gamma-ray spectrometry for plutonium analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, T.K.; Parker, J.L. (Los Alamos National Lab., NM (United States)); Kuno, Y.; Sato, S.; Kurosawa, A.; Akiyama, T. (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan))

    1991-01-01

    We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing {approximately}98% of {sup 239}Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

  13. Microstructure Related Characterization of a-Si:H Thin Films PECVD Deposited under Varied Hydrogen Dilution

    Directory of Open Access Journals (Sweden)

    Veronika Vavrunkova

    2007-01-01

    Full Text Available We report on the structure and optical properties of hydrogenated silicon thin films deposited by plasma - enhanced chemical vapor deposition (PECVD from silane diluted with hydrogen in a wide dilution range. The samples deposited with dilutions below 30 were detected as amorphous hydrogenated silicon (a-Si:H with crystalline grains of several nanometers in size which represent the medium-range order of a-Si:H. The optical characterization confirmed increasing ordering with the increasing dilution. The optical band gap was observed to be increasing function of the dilution.

  14. Study of Enzymatic Hydrolysis of Dilute Acid Pretreated Coconut Husk

    Directory of Open Access Journals (Sweden)

    Rudy Agustriyanto

    2012-12-01

    Full Text Available Coconut husk is classified as complex lignocellulosic material that contains cellulose, hemicellulose, lignin, and some other extractive compounds. Cellulose from coconut husk can be used as fermentation substrate after enzymatic hydrolysis. In contrary, lignin content from the coconut husk will act as an inhibitor in this hydrolysis process. Therefore, a pretreatment process is needed to enhance the hydrolysis of cellulose. The objective of this research is to investigate the production of the glucose through dilute acid pretreatment and to obtain its optimum operating conditions. In this study, the pretreatment was done using dilute sulfuric acid in an autoclave reactor. The pretreatment condition were varied at 80°C, 100°C, 120°C and 0.9%, 1.2%, 1.5% for temperature and acid concentration respectively. The acid pretreated coconut husk was then hydrolyzed using commercial cellulase (celluclast and β-glucosidase (Novozyme 188. The hydrolysis time was 72 hours and the operating conditions were varied at several temperature and pH. From the experimental results it can be concluded that the delignification temperature variation has greater influence than the acid concentration. The optimum operating condition was obtained at pH 4 and 50°C which was pretreated at 100°C using 1.5% acid concentration. Copyright © 2012 by BCREC UNDIP. All rights reserved. (Selected Paper from International Conference on Chemical and Material Engineering (ICCME 2012Received: 28th September 2012, Revised: 2nd October 2012, Accepted: 4th October 2012[How to Cite: R. Agustriyanto, A. Fatmawati, Y. Liasari. (2012. Study of Enzymatic Hydrolysis of Dilute Acid Pretreated Coconut Husk. Bulletin of Chemical Reaction Engineering & Catalysis, 7(2: 137-141. doi:10.9767/bcrec.7.2.4046.137-141] [How to Link / DOI: http://dx.doi.org/10.9767/bcrec.7.2.4046.137-141 ] | View in 

  15. Dilution-Induced Formation of Hybrid Perovskite Nanoplatelets.

    Science.gov (United States)

    Tong, Yu; Ehrat, Florian; Vanderlinden, Willem; Cardenas-Daw, Carlos; Stolarczyk, Jacek K; Polavarapu, Lakshminarayana; Urban, Alexander S

    2016-12-27

    Perovskite nanocrystals (NCs) are an important extension to the fascinating field of hybrid halide perovskites. Showing significantly enhanced photoluminescence (PL) efficiency and emission wavelengths tunable through halide content and size, they hold great promise for light-emitting applications. Despite the rapid advancement in this field, the physical nature and size-dependent excitonic properties have not been well investigated due to the challenges associated with their preparation. Herein we report the spontaneous formation of highly luminescent, quasi-2D organic-inorganic hybrid perovskite nanoplatelets (NPls) upon dilution of a dispersion of bulk-like NCs. The fragmentation of the large NCs is attributed to osmotic swelling induced by the added solvent. An excess of organic ligands in the solvent quickly passivates the newly formed surfaces, stabilizing the NPls in the process. The thickness of the NPls can be controlled both by the dilution level and by the ligand concentration. Such colloidal NPls and their thin films were found to be extremely stable under continuous UV light irradiation. Full tunability of the NPl emission wavelength is achieved by varying the halide ion used (bromide, iodide). Additionally, time-resolved PL measurements reveal an increasing radiative decay rate with decreasing thickness of the NPls, likely due to an increasing exciton binding energy. Similarly, measurements on iodide-containing NPls show a transformation from biexponential to monoexponential PL decay with decreasing thickness, likely due to an increasing fraction of excitonic recombination. This interesting phenomenon of change in fluorescence upon dilution is a result of the intricate nature of the perovskite material itself and is uncommon in inorganic materials. Our findings enable the synthesis of halide perovskite NCs with high quantum efficiency and good stability as well as a tuning of both their optical and morphological properties.

  16. Analyses of PWR boron dilution consequences with the Arrotta code

    International Nuclear Information System (INIS)

    Johanson, E.; Cheng, H.W.; Sehgal, B.R.

    1998-03-01

    During the past few years, major attention has been paid to analyzing the issue of reactivity initiated accidents (RIAs), of which the boron dilution event is of very special interest to the countries having pressurized water reactors (PWRs) in their nuclear power delivery systems. The scenario considered is that if an inadvertent accumulation of boron free water in one loop during reactor startup operations of a PWR and the inadvertent startup of the reactor coolant pump (RCP) in the loop. This could then lead to a rapid boron dilution in the core, which can in turn give rise to a power excursion. This report is devoted to studying the potential physical and thermal hydraulic consequences of a slug of diluted coolant entering the core after one RCP start under a couple of postulated cases. The severity of the consequences of such a scenario is primarily determined by the amount of positive reactivity insertion, and they are also related to the reactivity insertion rate. Therefore, in the report, detailed calculations and analyses have been carried out from case to case by using the well-known space-time kinetics code, ARROTTA. As a result, the spatial distribution for nodal power, fuel enthalpy, fuel temperature and clad outside temperature as well as the change in core reactivity, total core power and peak fuel temperature can be provided. In general, the maximum fuel enthalpy, peak fuel temperature, and clad outside temperature, for all the cases considered in the report, do not exceed their respective routine safety limitations because of the strong Doppler effect and moderator temperature feedback, except if the safety limitations on fuel enthalpy addition for high burnup fuel are drastically reduced

  17. Recovery of Platinum from Dilute Chloride Media Using Biosorbents

    Science.gov (United States)

    Zeytuncu, B.; Morcali, M. H.; Yucel, O.

    Pistachio nut shells and Rice husk, a biomass residue, were investigated as adsorbents for the platinum uptake from synthetically prepared dilute chloroplatinic acid solutions. The effects of the different uptake parameters on platinum uptake (%) were studied in detail on a batch sorption. Before the pistachio nut shell material was activated, platinum uptake (%) was poor compared with rice husk. However, after the pistachio nut shell material was activated at 1000°C under an argon atmosphere, the platinum uptake (%) increased two-fold. The pistachio nut shell (inactivated and activated) and rice husk were characterized by Attenuated Total Reflection-Fourier transform infrared spectroscopy (ATR-FTIR).

  18. Practical design of a heat exchanger for dilution refrigeration. 1

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Y; Fujii, G; Nagano, H [Tokyo Univ. (Japan). Inst. for Solid State Physics

    1978-02-01

    A compact heat exchanger for a dilution refrigerator with a high thermal efficiency is presented. Discrete heat exchangers with by-pass channels were used to decrease the flow impedance. This heat exchanger was designed so that the thermal conductance of liquid along the stream was greatly reduced. The effective thickness of the sponge material in the heat exchanger and mixer is also discussed. The obtained minimum temperatures of 12 mK was very close to the designed value of 10.8 mK. Moreover a rapid response was obtained. This is attributed to the small liquid volume of the heat exchanger.

  19. Redox substoichiometry in isotope dilution analysis Pt. 4

    International Nuclear Information System (INIS)

    Kambara, T.; Yoshioka, H.; Ugai, Y.

    1980-01-01

    The oxidation reaction of antimony(III) with potassium dichromate has been investigated radiometrically. The quantitative oxidation of antimony(III) was found to be not disturbed even in large amounts of tin(IV). On the basis of these results the redox substoichiometric isotope dilution analysis using potassium dichromate as the oxidizing agent was proposed for the determination of antimony in metallic tin. An antimony content of 1.22+-0.05 μg in metallic tin (10 mg) was determined without separation of the matrix element. (author)

  20. Redox substoichiometry in isotope dilution analysis Pt. 2

    International Nuclear Information System (INIS)

    Kambara, T.; Suzuki, J.; Yoshioka, H.; Nakajima, N.

    1978-01-01

    Isotope dilution analysis using the redox substoichiometric principle has been applied to the determination of antimony content in metallic zinc. As the substoichiometric reaction, the oxidation of trivalent to pentavalent antimony with potassium permanganate was used, followed by separation of these species by the BHPA extraction of trivalent antimony. Determination of antimony contents less than 0.5 μg was found to be possible with good accuracy, without separation of zinc ions. The antimony content in a metallic zinc sample was determined to be 19.7+-0.8 ppm, in good agreement with the results obtained by the other analytical methods. (author)

  1. Effect of fractons and magnons in dilute ferromagnets on resistivity

    International Nuclear Information System (INIS)

    Li Jianxin; Jiang Qing; Tian Decheng

    1993-01-01

    Based on the s - d exchange model, we investigate the temperature-dependent resistivity arising from the scattering of electrons off fractons and magnons in dilute Heisenberg ferromagnets on three-dimensional bond percolation network. The results indicate that the contribution of fracton scatterings to the resistivity varies from T 3 / 2 to T 2 dependence as the concentration of bonds approaches the percolation threshold, while the magnon scattering contributes a resistivity varying as T 3 / 2 regardless of the changes in concentration of bonds. (author). 21 refs, 4 figs

  2. Optical absorption of dilute solutions of metals in molten salts

    Energy Technology Data Exchange (ETDEWEB)

    Senatore, G.; Parrinello, M.; Tosi, M.P. (Trieste Univ. (Italy). Ist. di Fisica Teorica; Gruppo Nazionale di Struttura dell material del CNR, Trieste (Italy); International Centre for Theoretical Physics, Trieste (Italy))

    1978-12-23

    The theory of liquid structure for fluids of charged hard spheres is applied to an evaluation of the F-centre model for valence electrons in metal-molten salt solutions at high dilution. Minimization of the free energy yields the groundstate radius of the elctron bubble and hence the optical excitation energy in a Franck-Condon transition, the shift and broadening of the transition due to fluctuations in the bubble radius, the volume of mixing, and the activity of the salt in the solution.

  3. Cooperative fluorescence from a strongly driven dilute cloud of atoms

    DEFF Research Database (Denmark)

    Ott, Johan Raunkjær; Wubs, Martijn; Lodahl, Peter

    2013-01-01

    We investigate cooperative fluorescence in a dilute cloud of strongly driven two-level emitters. Starting from the Heisenberg equations of motion, we compute the first-order scattering corrections to the saturation of the excited-state population and to the resonance-fluorescence spectrum, which...... both require going beyond the state-of-the-art linear-optics approach to describe collective phenomena. A dipole blockade is observed due to long-range dipole-dipole coupling that vanishes at stronger driving fields. Furthermore, we compute the inelastic component of the light scattered by a cloud...

  4. Dispersion of Sound in Dilute Suspensions with Nonlinear Particle Relaxation

    Science.gov (United States)

    Kandula, Max

    2010-01-01

    The theory accounting for nonlinear particle relaxation (viscous and thermal) has been applied to the prediction of dispersion of sound in dilute suspensions. The results suggest that significant deviations exist for sound dispersion between the linear and nonlinear theories at large values of Omega(Tau)(sub d), where Omega is the circular frequency, and Tau(sub d) is the Stokesian particle relaxation time. It is revealed that the nonlinear effect on the dispersion coefficient due to viscous contribution is larger relative to that of thermal conduction

  5. Condensate statistics in interacting and ideal dilute bose gases

    Science.gov (United States)

    Kocharovsky; Kocharovsky; Scully

    2000-03-13

    We obtain analytical formulas for the statistics, in particular, for the characteristic function and all cumulants, of the Bose-Einstein condensate in dilute weakly interacting and ideal equilibrium gases in the canonical ensemble via the particle-number-conserving operator formalism of Girardeau and Arnowitt. We prove that the ground-state occupation statistics is not Gaussian even in the thermodynamic limit. We calculate the effect of Bogoliubov coupling on suppression of ground-state occupation fluctuations and show that they are governed by a pair-correlation, squeezing mechanism.

  6. Tailoring spin-orbit torque in diluted magnetic semiconductors

    KAUST Repository

    Li, Hang; Wang, Xuhui; Doǧan, Fatih; Manchon, Aurelien

    2013-01-01

    We study the spin orbit torque arising from an intrinsic linear Dresselhaus spin-orbit coupling in a single layer III-V diluted magnetic semiconductor. We investigate the transport properties and spin torque using the linear response theory, and we report here: (1) a strong correlation exists between the angular dependence of the torque and the anisotropy of the Fermi surface; (2) the spin orbit torque depends nonlinearly on the exchange coupling. Our findings suggest the possibility to tailor the spin orbit torque magnitude and angular dependence by structural design.

  7. Thermodynamics of dilute gases: application to submonolayer He films

    International Nuclear Information System (INIS)

    Vetrovec, M.B.; Carneiro, G.M.

    1979-01-01

    The thermodynamic properties of submonolayer He films are calculated. Expressions are first obtained for the thermodynamic properties of dilute systems of particles interacting through a short range potential taking into account binary interactions between the particles. These expressions are exact in the limit n→0, n being the particle number density, and are valid at all temperatures. At high temperatures these expressions are reduced to those obtained using the virial expansion truncated after the second term. These expressions are next applied to He in two dimensions and the results compared with experiment and with previous calculations [pt

  8. CALCULATING THE EFFECT OF EMPLOYEE STOCK OPTIONS ON DILUTED EPS

    OpenAIRE

    van Zyl, Warrick Boyd

    2007-01-01

    This paper focuses on how to calculate diluted earnings per share (DEPS) when a firm has outstanding employee stock options (ESOs). Three possible methods are described and compared. The first is the current International Accounting Standard 33 – Earnings Per Share (IAS 33) approach which is based on the intrinsic value of the ESOs. The second method, advocated by Core et al. (2002), is very similar to that of IAS 33 but instead of the intrinsic value uses the fair value of the outstanding...

  9. Radiolysis of dilute aqueous solutions of cesium iodide

    International Nuclear Information System (INIS)

    Gorbovitskaya, T.I.; Galinkin, D.L.; Kants, L.K.; Tiliks, Yu.E.; Kotelkin, I.M.; Luzanova, L.M.

    1993-01-01

    Study of physical-chemical processes in the NPP containment by severe accident is carried out. Radiolysis of reactor cooling water containing iodine and cesium radionuclides penetrated therein in the course of accident is considered as of such processes. Role of ionizing radiation in the process of formation and release of ecologically hazardous volatile forms of radioiodine from reactor water into environment is studied. Experiments on radiolysis of CsI diluted water solutions are carried out. The data obtained were used for clarification of radiolysis mechanism for iodine-containing water system, enabling forecast of iodine behaviour in the course of the accident. 5 refs., 4 figs., 1 tab

  10. Dilute bismides for near and mid-infrared applications

    DEFF Research Database (Denmark)

    Song, Yuxin; Gu, Yi; Ye, Hong

    2013-01-01

    Dilute bismides are a group of emerging materials with unique properties. Incorporation of a small amount of Bi in common III–V host materials results in large band-gap reduction and strong spin-orbit splitting, leading to potential applications in near-infrared (NIR) and mid-infrared (MIR......) optoelectronics. Recent progresses on molecular beam epitaxy (MBE) of novel III-Sb-Bi, i.e. GaSbBi and InSbBi thin films from our group are summarised in this paper. Quantum well structures based on GaSbBi and InGaAsBi aiming for the optical communication window were grown and characterized....

  11. Tailoring spin-orbit torque in diluted magnetic semiconductors

    KAUST Repository

    Li, Hang

    2013-05-16

    We study the spin orbit torque arising from an intrinsic linear Dresselhaus spin-orbit coupling in a single layer III-V diluted magnetic semiconductor. We investigate the transport properties and spin torque using the linear response theory, and we report here: (1) a strong correlation exists between the angular dependence of the torque and the anisotropy of the Fermi surface; (2) the spin orbit torque depends nonlinearly on the exchange coupling. Our findings suggest the possibility to tailor the spin orbit torque magnitude and angular dependence by structural design.

  12. Scanning Hall probe microscopy of a diluted magnetic semiconductor

    International Nuclear Information System (INIS)

    Kweon, Seongsoo; Samarth, Nitin; Lozanne, Alex de

    2009-01-01

    We have measured the micromagnetic properties of a diluted magnetic semiconductor as a function of temperature and applied field with a scanning Hall probe microscope built in our laboratory. The design philosophy for this microscope and some details are described. The samples analyzed in this work are Ga 0.94 Mn 0.06 As films grown by molecular beam epitaxy. We find that the magnetic domains are 2-4 μm wide and fairly stable with temperature. Magnetic clusters are observed above T C , which we ascribe to MnAs defects too small and sparse to be detected by a superconducting quantum interference device magnetometer.

  13. Scanning Hall probe microscopy of a diluted magnetic semiconductor

    Science.gov (United States)

    Kweon, Seongsoo; Samarth, Nitin; de Lozanne, Alex

    2009-05-01

    We have measured the micromagnetic properties of a diluted magnetic semiconductor as a function of temperature and applied field with a scanning Hall probe microscope built in our laboratory. The design philosophy for this microscope and some details are described. The samples analyzed in this work are Ga0.94Mn0.06As films grown by molecular beam epitaxy. We find that the magnetic domains are 2-4 μm wide and fairly stable with temperature. Magnetic clusters are observed above TC, which we ascribe to MnAs defects too small and sparse to be detected by a superconducting quantum interference device magnetometer.

  14. Yfiler® Plus population samples and dilution series

    DEFF Research Database (Denmark)

    Andersen, Mikkel Meyer; Mogensen, Helle Smidt; Eriksen, Poul Svante

    2017-01-01

    DNA complicated the analysis by causing drop-ins of characteristic female DNA artefacts. Even though the customised analytical threshold in combination with the custom-made artefact filters gave more alleles, crime scene samples still needed special attention from the forensic geneticist....... dynamics and performance. We determined dye-dependent analytical thresholds by receiver operating characteristics (ROC) and made a customised artefact filter that includes theoretical known artefacts by use of previously analysed population samples. Dilution series of known male DNA and a selection...

  15. Domain walls in (Ga,Mn)As diluted magnetic semiconductor

    Czech Academy of Sciences Publication Activity Database

    Sugawara, A.; Kasai, H.; Tonomura, A.; Brown, P.D.; Campion, R. P.; Edmonds, K. W.; Gallagher, B. L.; Zemen, Jan; Jungwirth, Tomáš

    2008-01-01

    Roč. 100, č. 4 (2008), 047202/1-047202/4 ISSN 0031-9007 R&D Projects: GA MŠk LC510; GA ČR GEFON/06/E002; GA ČR GA202/05/0575; GA ČR GA202/04/1519 EU Projects: European Commission(XE) 015728 - NANOSPIN Institutional research plan: CEZ:AV0Z10100521 Keywords : dilute ferromagnetic semiconductor * Néel domain walls * electron holography * Landau-Lifshitz-Gilbert simulation Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 7.180, year: 2008

  16. Magneto-electrochemical recovery of diluted metals using three-dimensionally structured electrodes

    Science.gov (United States)

    Fernández, Dámaris; Romeral, Luis; Lyons, Michael E. G.

    2015-04-01

    In a typical metal recovery process, where highly purified metals are obtained from a concentrated electrolyte, usually the cathodic electrodes are planar and can be described mainly as bi-dimensional. This leads to a low space-time yield and low normalized space velocity with an impact on production rates. New requirements of low-energy consumption yet intensive production factories impose the need to adequate electrodes in order to comply. Furthermore, a reduction in the number of steps required to achieve a product would be ideal. This suggests that direct electro-precipitation of metals contained in diluted electrolytes would be in principle a desirable technique to implement. However, the less concentrated the solution, the higher the IR drop becomes, making the process more energy-consuming and current efficiency strongly decays. Good potential alternatives arise from three-dimensionally designed electrodes in the form of mesh, porous or fluidized beds, for instance, and several examples are well known in literature. Nevertheless, current efficiency can still be a problem in the more diluted electrolytes. Furthermore, the anodic electrode, where the counter reaction takes place, plays also an important role in determining the current efficiency of the overall process. In this case, the liquid-to-gas phase transition implies that the electrodes get a strong gas shield that increases the IR drop. Whereas shifting from bi-dimensional to three-dimensional electrodes could provide an alternative for achieving better performances, it is still far from the expected targets. Therefore alternative or complementary techniques to improve efficiency are required. It is well known that magnetic fields coupled with electric fields enhance mass transport via de Lorentz and other forces. In this work, the applications and properties of three-dimensional arrays subject to magnetic field interactions are examined and compared with the traditional bi-dimensional electrodes

  17. Effect of the dilution factor on {sup 18}FDG and Na{sup 18}F samples for bacterial endotoxin test using PTS (portable test system)

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z., E-mail: mbs@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    {sup 18}FDG and Na{sup 18}F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as {sup 18}F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of {sup 18}FDG and Na{sup 18}F for PTS analysis. Two different dilution factors for {sup 18}FDG and 1:10 for Na{sup 18}F were essayed: 1:10 and 1:100. {sup 18}FDG and Na{sup 18} solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for {sup 18}FDG and 1:10 for Na{sup 18}F. The recovery of the product positive control was 98-12% for {sup 18}FDG 1:100 and 104-120% for Na{sup 18}F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for {sup 18}FDG and Na{sup 18}F routine endotoxin test. (author)

  18. Effect of the dilution factor on 18FDG and Na18F samples for bacterial endotoxin test using PTS (portable test system)

    International Nuclear Information System (INIS)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z.

    2011-01-01

    18 FDG and Na 18 F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as 18 F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of 18 FDG and Na 18 F for PTS analysis. Two different dilution factors for 18 FDG and 1:10 for Na 18 F were essayed: 1:10 and 1:100. 18 FDG and Na 18 solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for 18 FDG and 1:10 for Na 18 F. The recovery of the product positive control was 98-12% for 18 FDG 1:100 and 104-120% for Na 18 F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for 18 FDG and Na 18 F routine endotoxin test. (author)

  19. Dilution correction equation revisited: The impact of stream slope, relief ratio and area size of basin on geochemical anomalies

    Science.gov (United States)

    Shahrestani, Shahed; Mokhtari, Ahmad Reza

    2017-04-01

    Stream sediment sampling is a well-known technique used to discover the geochemical anomalies in regional exploration activities. In an upstream catchment basin of stream sediment sample, the geochemical signals originating from probable mineralization could be diluted due to mixing with the weathering material coming from the non-anomalous sources. Hawkes's equation (1976) was an attempt to overcome the problem in which the area size of catchment basin was used to remove dilution from geochemical anomalies. However, the metal content of a stream sediment sample could be linked to several geomorphological, sedimentological, climatic and geological factors. The area size is not itself a comprehensive representative of dilution taking place in a catchment basin. The aim of the present study was to consider a number of geomorphological factors affecting the sediment supply, transportation processes, storage and in general, the geochemistry of stream sediments and their incorporation in the dilution correction procedure. This was organized through employing the concept of sediment yield and sediment delivery ratio and linking such characteristics to the dilution phenomenon in a catchment basin. Main stream slope (MSS), relief ratio (RR) and area size (Aa) of catchment basin were selected as the important proxies (PSDRa) for sediment delivery ratio and then entered to the Hawkes's equation. Then, Hawkes's and new equations were applied on the stream sediment dataset collected from Takhte-Soleyman district, west of Iran for Au, As and Sb values. A number of large and small gold, antimony and arsenic mineral occurrences were used to evaluate the results. Anomaly maps based on the new equations displayed improvement in anomaly delineation taking the spatial distribution of mineral deposits into account and could present new catchment basins containing known mineralization as the anomaly class, especially in the case of Au and As. Four catchment basins having Au and As

  20. Impaired Urine Dilution Capability in HIV Stable Patients

    Directory of Open Access Journals (Sweden)

    Waldo H. Belloso

    2014-01-01

    Full Text Available Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle’s loop (TALH is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney’s ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz’ test. Material & Methods. Chaimowitz’ test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir.

  1. Entanglement and Zeeman interaction in diluted magnetic semiconductor quantum dot

    International Nuclear Information System (INIS)

    Hichri, A.; Jaziri, S.

    2004-01-01

    We present theoretically the Zeeman coupling and exchange-induced swap action in spin-based quantum dot quantum computer models in the presence of magnetic field. We study the valence and conduction band states in a double quantum dots made in diluted magnetic semiconductor. The latter have been proven to be very useful in building an all-semiconductor platform for spintronics. Due to a strong p-d exchange interaction in diluted magnetic semiconductor (Cd 0.57 Mn 0.43 Te), the relative contribution of this component is strongly affected by an external magnetic field, a feature that is absent in nonmagnetic double quantum dots. We determine the energy spectrum as a function of magnetic field within the Hund-Mulliken molecular-orbit approach and by including the Coulomb interaction. Since we show that the ground state of the two carriers confined in a vertically coupled quantum dots provide a possible realization for a gate of a quantum computer, the crossing between the lowest states, caused by the giant spin splitting, can be observed as a pronounced jump in the magnetization of small magnetic field amplitude. Finally, we determine the swap time as a function of magnetic field and the inter dot distance. We estimate quantitatively swap errors caused by the field, establishing that error correction would, in principle, be possible in the presence of nonuniform magnetic field in realistic structures

  2. Large-deviation theory for diluted Wishart random matrices

    Science.gov (United States)

    Castillo, Isaac Pérez; Metz, Fernando L.

    2018-03-01

    Wishart random matrices with a sparse or diluted structure are ubiquitous in the processing of large datasets, with applications in physics, biology, and economy. In this work, we develop a theory for the eigenvalue fluctuations of diluted Wishart random matrices based on the replica approach of disordered systems. We derive an analytical expression for the cumulant generating function of the number of eigenvalues IN(x ) smaller than x ∈R+ , from which all cumulants of IN(x ) and the rate function Ψx(k ) controlling its large-deviation probability Prob[IN(x ) =k N ] ≍e-N Ψx(k ) follow. Explicit results for the mean value and the variance of IN(x ) , its rate function, and its third cumulant are discussed and thoroughly compared to numerical diagonalization, showing very good agreement. The present work establishes the theoretical framework put forward in a recent letter [Phys. Rev. Lett. 117, 104101 (2016), 10.1103/PhysRevLett.117.104101] as an exact and compelling approach to deal with eigenvalue fluctuations of sparse random matrices.

  3. Novel understanding of calcium silicate hydrate from dilute hydration

    KAUST Repository

    Zhang, Lina

    2017-05-13

    The perspective of calcium silicate hydrate (C-S-H) is still confronting various debates due to its intrinsic complicated structure and properties after decades of studies. In this study, hydration at dilute suspension of w/s equaling to 10 was conducted for tricalcium silicate (C3S) to interpret long-term hydration process and investigate the formation, structure and properties of C-S-H. Based on results from XRD, IR, SEM, NMR and so forth, loose and dense clusters of C-S-H with analogous C/S ratio were obtained along with the corresponding chemical formulae proposed as Ca5Si4O13∙6.2H2O. Crystalline structure inside C-S-H was observed by TEM, which was allocated at the foil-like proportion as well as the edge of wrinkles of the product. The long-term hydration process of C3S in dilute suspension could be sketchily described as migration of calcium hydroxide and in-situ growth of C-S-H with equilibrium silicon in aqueous solution relatively constant and calcium varied.

  4. Host polymer influence on dilute polystyrene segmental dynamics

    Science.gov (United States)

    Lutz, T. R.

    2005-03-01

    We have utilized deuterium NMR to investigate the segmental dynamics of dilute (2%) d3-polystyrene (PS) chains in miscible polymer blends with polybutadiene, poly(vinyl ethylene), polyisoprene, poly(vinyl methylether) and poly(methyl methacrylate). In the dilute limit, we find qualitative differences depending upon whether the host polymer has dynamics that are faster or slower than that of pure PS. In blends where PS is the fast (low Tg) component, segmental dynamics are slowed upon blending and can be fit by the Lodge-McLeish model. When PS is the slow (high Tg) component, PS segmental dynamics speed up upon blending, but cannot be fit by the Lodge-McLeish model unless a temperature dependent self-concentration is employed. These results are qualitatively consistent with a recent suggestion by Kant, Kumar and Colby (Macromolecules, 2003, 10087), based upon data at higher concentrations. Furthermore, as the slow component, we find the segmental dynamics of PS has a temperature dependence similar to that of its host. This suggests viewing the high Tg component dynamics in a miscible blend as similar to a polymer in a low molecular weight solvent.

  5. Automatic processing of isotopic dilution curves obtained by precordial detection

    International Nuclear Information System (INIS)

    Verite, J.C.

    1973-01-01

    Dilution curves pose two distinct problems: that of their acquisition and that of their processing. A study devoted to the latter aspect only was presented. It was necessary to satisfy two important conditions: the treatment procedure, although applied to a single category of curves (isotopic dilution curves obtained by precordial detection), had to be as general as possible; to allow dissemination of the method the equipment used had to be relatively modest and inexpensive. A simple method, considering the curve processing as a process identification, was developed and should enable the mean heart cavity volume and certain pulmonary circulation parameters to be determined. Considerable difficulties were encountered, limiting the value of the results obtained though not condemning the method itself. The curve processing question raised the problem of their acquisition, i.e. the number of these curves and their meaning. A list of the difficulties encountered is followed by a set of possible solutions, a solution being understood to mean a curve processing combination where the overlapping between the two aspects of the problem is accounted for [fr

  6. Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Liu, Jiwei; Li, Haiyang

    2016-03-01

    Exhaled nitric oxide (NO) is one of the most promising breath markers for respiratory diseases. Its profile for exhalation and the respiratory NO production sites can provide useful information for medical disease diagnosis and therapeutic procedures. However, the high-level moisture in exhaled gas always leads to the poor selectivity and sensitivity for ion spectrometric techniques. Herein, a method based on fast non-equilibrium dilution ion mobility spectrometry (NED-IMS) was firstly proposed to directly monitor the exhaled NO profile on line. The moisture interference was eliminated by turbulently diluting the original moisture to 21% of the original with the drift gas and dilution gas. Weak enhancement was observed for humid NO response and its limit of detection at 100% relative humidity was down to 0.58 ppb. The NO concentrations at multiple exhalation flow rates were measured, while its respiratory production sites were determined by using two-compartment model (2CM) and Högman and Meriläinen algorithm (HMA). Last but not the least, the NO production sites were analyzed hourly to tentatively investigate the daily physiological process of NO. The results demonstrated the capacity of NED-IMS in the real-time analysis of exhaled NO and its production sites for clinical diagnosis and assessment.

  7. Effects of hydrogen addition and nitrogen dilution on the laminar flame characteristics of premixed methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tahtouh, T.; Halter, F.; Mounaim-Rousselle, C. [Institut PRISME, Universite d' Orleans, 8 rue Leonard de Vinci-45072, Orleans Cedex 2 (France); Samson, E. [PSA Peugeot Citroen (France)

    2009-10-15

    The effect of hydrogen addition and nitrogen dilution on laminar flame characteristics was investigated. The spherical expanding flame technique, in a constant volume bomb, was employed to extract laminar flame characteristics. The mole fraction of hydrogen in the methane-hydrogen mixture was varied from 0 to 1 and the mole fraction of nitrogen in the total mixture (methane-hydrogen-air-diluent) from 0 to 0.35. Measurements were performed at an initial pressure of 0.1 MPa and an initial temperature of 300 K. The mixtures investigated were under stoichiometric conditions. Based on experimental measurements, a new correlation for calculating the laminar burning velocity of methane-hydrogen-air-nitrogen mixtures is proposed. The laminar burning velocity was found to increase linearly with hydrogen mass fraction for all dilution ratios while the burned gas Markstein length decreases with the increase in hydrogen amount in the mixture except for high hydrogen mole fractions (>0.6). Nitrogen dilution has a nonlinear reducing effect on the laminar burning velocity and an increasing effect on the burned gas Markstein length. The experimental results and the proposed correlation obtained are in good agreement with literature values. (author)

  8. Isotope dilution alpha spectrometry for the determination of plutonium concentration in irradiated fuel dissolver solution : IDAS and R-IDAS

    International Nuclear Information System (INIS)

    Ramaniah, M.V.; Jain, H.C.; Aggarwal, S.K.; Chitambar, S.A.; Kavimandan, V.D.; Almaula, A.I.; Shah, P.M.; Parab, A.R.; Sant, V.L.

    1980-01-01

    The report presents a new technique, Isotope Dilution Alpha Spectrometry (IDAS) and Reverse Isotope Dilution Alpha Spectrometry (R-IDAS) for determining the concentration of plutonium in the irradiated fuel dissolver solution. The method exploits sup(238)Pu in IDAS and sup(239)Pu in R-IDAS as a spike and provides an alternative method to Isotope Dilution Mass Spectrometry (IDMS) which requires enriched sup(242)Pu as a spike. Depending upon the burn-up of the fuel, sup(238)Pu or sup(239)Pu is used as a spike to change the sup(238)Pu/(sup(239)Pu+sup(240)Pu)α activity ratio in the sample by a factor of 10. This change is determined by α-spectrometry on electrodeposited sources using a solid state silicon surface barrier detector coupled to a multichannel analyser. The validity of a simple method based on the geometric progression (G.P.) decrease for the far tail of the spectrum to correct for the tail contribution of sup(238)Pu peak (5.50 MeV) to the low energy sup(239)Pu + sup(240)Pu peak (5.17 MeV) is established. Results for the plutonium concentration on different irradiated fuel dissolver solutions with burn-uo ranging from J,000 to 100,000 MWD/TU are presented and compared with those obtained by IDMS. The values obtained by IDAS or R-IDAS and IDMS agree within 0.5%. (auth.)

  9. Development of analytical techniques for determining rare earth elements in geological materials

    International Nuclear Information System (INIS)

    Moraes, Noemia M.P. de; Kakazu, M.H.; Iyer, S.S.

    1987-01-01

    This work presents a comparative study between instrumental neutron activation analysis, inductively coupled plasma emission spectrometry and mass spectrometric isotope dilution techniques. Some advantages and disadvantages of the techniques are presented, depending on the type of the analysis required. Emphasis in give upon mass spectrometric isotope dilution, and some procedures for the development of this technique are presented. This methodology is being established by the nuclear and isotopic geology group of the IPEN. (author) [pt

  10. Application of radioisotope techniques in analysis of environmental pollutants

    International Nuclear Information System (INIS)

    Kyrs, M.; Moravec, A.

    1984-01-01

    A survey is tabulated of the use of radioisotope techniques, giving the detected pollutant and the sensitivity and accuracy of the method. The most frequently used principle is the substoichiometric variant of isotope dilution which may be divided into the method of isotope dilution and the radio-reagent method. Both methods are described and examples are given of the determination of pollutants. (J.P.)

  11. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  12. A new trajectory correction technique for linacs

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.; Ruth, R.D.

    1990-06-01

    In this paper, we describe a new trajectory correction technique for high energy linear accelerators. Current correction techniques force the beam trajectory to follow misalignments of the Beam Position Monitors. Since the particle bunch has a finite energy spread and particles with different energies are deflected differently, this causes ''chromatic'' dilution of the transverse beam emittance. The algorithm, which we describe in this paper, reduces the chromatic error by minimizing the energy dependence of the trajectory. To test the method we compare the effectiveness of our algorithm with a standard correction technique in simulations on a design linac for a Next Linear Collider. The simulations indicate that chromatic dilution would be debilitating in a future linear collider because of the very small beam sizes required to achieve the necessary luminosity. Thus, we feel that this technique will prove essential for future linear colliders. 3 refs., 6 figs., 2 tabs

  13. Determination of sulfur in steels by isotope dilution mass spectrometry after dissolution with sealed tube

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1981-01-01

    The scaled tube dissolution technique was studied for the complete conversion of sulfur in steels to sulfate. Isotope dilution mass spectrometry was used for the determination of sulfur in the sulfate. Sample (0.5 g) was dissolved in nitric acid (7 ml) and hydrochloric acid (3 ml) in a scaled borosilicate glass tube on being heated above 180 0 C overnight. Nitrate ions were removed by repeated evaporation with hydrochloric acid. The residue was dissolved in hydrochloric acid. Sulfate was reduced with a mixture of hydrochloric, hydroiodic and hypophosphorous acids; hydrogen sulfide evolved was absorbed in cadmium acetate solution, then converted to silver sulfide, which was burned to sulfur dioxide in pure oxygen at low pressure, for isotopic analysis. Analytical blank in whole procedure was 0.8 μg of sulfur. This technique was applied to the determination of sulfur in NBS low alloy steels. The principal cause of low values obtained by the open beaker dissolution technique was evaporation losses of sulfur as sulfur dioxide during the dissolution. (author)

  14. Effects of diluents on soot surface temperature and volume fraction in diluted ethylene diffusion flames at pressure

    KAUST Repository

    Kailasanathan, Ranjith Kumar Abhinavam

    2014-05-20

    Soot surface temperature and volume fraction are measured in ethylene/air coflowing laminar diffusion flames at high pressures, diluted with one of four diluents (argon, helium, nitrogen, and carbon dioxide) using a two-color technique. Both temperature and soot measurements presented are line-of-sight averages. The results aid in understanding the kinetic and thermodynamic behavior of the soot formation and oxidation chemistry with changes in diluents, ultimately leading to possible methods of reducing soot emission from practical combustion hardware. The diluted fuel and coflow exit velocities (top-hat profiles) were matched at all pressures to minimize shear effects. In addition to the velocity-matched flow rates, the mass fluxes were held constant for all pressures. Addition of a diluent has a pronounced effect on both the soot surface temperature and volume fraction, with the helium diluted flame yielding the maximum and carbon dioxide diluted flame yielding minimum soot surface temperature and volume fraction. At low pressures, peak soot volume fraction exists at the tip of the flame, and with an increase in pressure, the location shifts lower to the wings of the flame. Due to the very high diffusivity of helium, significantly higher temperature and volume fraction are measured and explained. Carbon dioxide has the most dramatic soot suppression effect. By comparing the soot yield with previously measured soot precursor concentrations in the same flame, it is clear that the lower soot yield is a result of enhanced oxidation rates rather than a reduction in precursor formation. Copyright © 2014 Taylor & Francis Group, LLC.

  15. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Xue [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Fang Xiaowei [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China); Yu Zhiqiang; Sheng Guoying [Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Wu Minghong [Shanghai Applied Radiation Institute, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Fu Jiamo [Institute of Environmental Pollution and Health, School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Guangdong Key Laboratory of Environmental Protection and Resource Utilization, State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Chen Huanwen, E-mail: chw8868@gmail.com [Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Applied Chemistry Department, East China Institute of Technology, Nanchang 330013 (China)

    2012-10-20

    Highlights: Black-Right-Pointing-Pointer High throughput analysis of urinary creatinine is achieved by using ID-EESI-MS/MS. Black-Right-Pointing-Pointer Urine sample is directly analyzed and no sample pre-treatment is required. Black-Right-Pointing-Pointer Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI-MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 {mu}g L{sup -1}. Over the concentration range investigated (0.05-10 mg L{sup -1}), the calibration curve was obtained with satisfactory linearity (R{sup 2} = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1-11.8% (n = 6) and 4.1-11.3% (n = 6), respectively. The isotope dilution EESI-MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85-111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI-MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  16. Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Li Xue; Fang Xiaowei; Yu Zhiqiang; Sheng Guoying; Wu Minghong; Fu Jiamo; Chen Huanwen

    2012-01-01

    Highlights: ► High throughput analysis of urinary creatinine is achieved by using ID-EESI–MS/MS. ► Urine sample is directly analyzed and no sample pre-treatment is required. ► Accurate quantification is accomplished with isotope dilution technique. - Abstract: Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI–MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 μg L −1 . Over the concentration range investigated (0.05–10 mg L −1 ), the calibration curve was obtained with satisfactory linearity (R 2 = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1–11.8% (n = 6) and 4.1–11.3% (n = 6), respectively. The isotope dilution EESI–MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85–111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI–MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.

  17. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  18. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  19. ''Over the horizon'' SANS: Measurements on near-surface Poiseuille shear-induced ordering of dilute solutions of threadlike micelles

    International Nuclear Information System (INIS)

    Hamilton, W.A.; Butler, P.D.; Hayter, J.B.; Magid, L.J.; Kreke, P.J.

    1995-01-01

    Although the behavior of a fluid under shear near a surface can be expected to be critically important to its drag and lubrication properties, most shear measurements to date have been of the bulk. This paper outlines the use of a specially developed Poiseuille shear cell at grazing incidence to measure the small-angle neutron scattering (SANS) signal from the first few tens of microns in the interfacial region. The authors illustrate the technique with measurements made on the near-surface ordering in flow past a quartz surface of dilute surfactant solutions comprising highly extended self-assembling ''threadlike'' micelles

  20. Extended Macroscopic Study of Dilute Gas Flow within a Microcavity

    Directory of Open Access Journals (Sweden)

    Mohamed Hssikou

    2016-01-01

    Full Text Available The behaviour of monatomic and dilute gas is studied in the slip and early transition regimes using the extended macroscopic theory. The gas is confined within a two-dimensional microcavity where the longitudinal sides are in the opposite motion with constant velocity ±Uw. The microcavity walls are kept at the uniform and reference temperature T0. Thus, the gas flow is transported only by the shear stress induced by the motion of upper and lower walls. From the macroscopic point of view, the regularized 13-moment equations of Grad, R13, are solved numerically. The macroscopic gas proprieties are studied for different values of the so-called Knudsen number (Kn, which gives the gas-rarefaction degree. The results are compared with those obtained using the classical continuum theory of Navier-Stokes and Fourier (NSF.

  1. Differential isospin-fractionation in dilute asymmetric nuclear matter

    International Nuclear Information System (INIS)

    Li Baoan; Chen Liewen; Ma Hongru; Xu Jun; Yong Gaochan

    2007-01-01

    The differential isospin-fractionation (IsoF) during the liquid-gas phase transition in dilute asymmetric nuclear matter is studied as a function of nucleon momentum. Within a self-consistent thermal model it is shown that the neutron/proton ratio of the gas phase becomes smaller than that of the liquid phase for energetic nucleons, although the gas phase is overall more neutron-rich. Clear indications of the differential IsoF consistent with the thermal model predictions are demonstrated within a transport model for heavy-ion reactions. Future comparisons with experimental data will allow us to extract critical information about the momentum dependence of the isovector strong interaction

  2. Two-body correlation functions in dilute nuclear matter

    International Nuclear Information System (INIS)

    Isayev, A A

    2006-01-01

    Finding the distinct features of the crossover from the regime of large overlapping Cooper pairs to the limit of non-overlapping pairs of fermions (Shafroth pairs) in multicomponent Fermi systems remains one of the actual problems in a quantum many-body theory. Here this transition is studied by calculating the two-body density, spin and isospin correlation functions in dilute asymmetric nuclear matter. It is shown that criterion of the crossover (Phys. Rev. Lett. 95, 090402 (2005)), consisting in the change of the sign of the density correlation function at low momentum transfer, fails to describe correctly the density-driven BEC-BCS transition at finite isospin asymmetry or finite temperature. As an unambiguous signature of the BEC-BCS transition, there can be used the presence (BCS regime) or absence (BEC regime) of the singularity in the momentum distribution of the quasiparticle density of states

  3. Superfluidity of a dilute 3He-4He solution

    International Nuclear Information System (INIS)

    Soda, Toshio

    1993-01-01

    The interaction between two 3 He atoms is calculated by taking into account the backflow effect of 3 He by the 4 He in the 3 He- 4 He mixture. The effect contributes solely to the P wave part of the interaction. The repulsive S wave part of the contact interaction contributes to the exchange interaction between the 3 He atoms, while the direct one phonon exchange interaction contributes both to the S and P wave attractive interactions. The overall contribution to the attractive interaction is dominated by the P wave part and the superfluidity in the P wave is more predominant than in the S wave for the 5 % dilute 3 He- 4 He solution, and vice versa for the 1.3 % solution. (author)

  4. Development of curcumin liposome formulations using polyol dilution method

    Directory of Open Access Journals (Sweden)

    Lalana Kongkaneramit

    2016-12-01

    Full Text Available This study was aimed to formulate curcumin liposomes (CLs by using polyol dilution method which is advantageous for no residue of organic solvent. CLs were the mixture of hydrogenated phosphatidylcholine (PC and cholesterol (CH at the molar ratio of 9:1. Propylene glycol (PG, glycerin, and polyethylene glycol 400 (PEG-400 were used as polyol solvent. Extrusion was applied after the suspension formed. The amount of polyol and curcumin and preparing temperature were investigated. The obtained suspensions were observed for appearance, size, size distribution, zeta potential, morphology, and percentage of entrapment. The results showed that type and amount of polyol had an impact on both liposomal size and the amount of entrapped curcumin, while preparing temperature was also an important factor. However, the solubility of lipids and drug in a given polyol should be considered because of loading efficiency in the formulation.

  5. Split-plot designs for robotic serial dilution assays.

    Science.gov (United States)

    Buzas, Jeffrey S; Wager, Carrie G; Lansky, David M

    2011-12-01

    This article explores effective implementation of split-plot designs in serial dilution bioassay using robots. We show that the shortest path for a robot to fill plate wells for a split-plot design is equivalent to the shortest common supersequence problem in combinatorics. We develop an algorithm for finding the shortest common supersequence, provide an R implementation, and explore the distribution of the number of steps required to implement split-plot designs for bioassay through simulation. We also show how to construct collections of split plots that can be filled in a minimal number of steps, thereby demonstrating that split-plot designs can be implemented with nearly the same effort as strip-plot designs. Finally, we provide guidelines for modeling data that result from these designs. © 2011, The International Biometric Society.

  6. Gel phase formation in dilute triblock copolyelectrolyte complexes

    Science.gov (United States)

    Srivastava, Samanvaya; Andreev, Marat; Levi, Adam E.; Goldfeld, David J.; Mao, Jun; Heller, William T.; Prabhu, Vivek M.; de Pablo, Juan J.; Tirrell, Matthew V.

    2017-02-01

    Assembly of oppositely charged triblock copolyelectrolytes into phase-separated gels at low polymer concentrations (simulations. Here we show that in contrast to uncharged, amphiphilic block copolymers that form discrete micelles at low concentrations and enter a phase of strongly interacting micelles in a gradual manner with increasing concentration, the formation of a dilute phase of individual micelles is prevented in polyelectrolyte complexation-driven assembly of triblock copolyelectrolytes. Gel phases form and phase separate almost instantaneously on solvation of the copolymers. Furthermore, molecular models of self-assembly demonstrate the presence of oligo-chain aggregates in early stages of copolyelectrolyte assembly, at experimentally unobservable polymer concentrations. Our discoveries contribute to the fundamental understanding of the structure and pathways of complexation-driven assemblies, and raise intriguing prospects for gel formation at extraordinarily low concentrations, with applications in tissue engineering, agriculture, water purification and theranostics.

  7. High-throughput ab-initio dilute solute diffusion database.

    Science.gov (United States)

    Wu, Henry; Mayeshiba, Tam; Morgan, Dane

    2016-07-19

    We demonstrate automated generation of diffusion databases from high-throughput density functional theory (DFT) calculations. A total of more than 230 dilute solute diffusion systems in Mg, Al, Cu, Ni, Pd, and Pt host lattices have been determined using multi-frequency diffusion models. We apply a correction method for solute diffusion in alloys using experimental and simulated values of host self-diffusivity. We find good agreement with experimental solute diffusion data, obtaining a weighted activation barrier RMS error of 0.176 eV when excluding magnetic solutes in non-magnetic alloys. The compiled database is the largest collection of consistently calculated ab-initio solute diffusion data in the world.

  8. Preservation Study for Ultra-Dilute VX Standards | Science ...

    Science.gov (United States)

    Report Lawrence Livermore National Laboratory (LLNL) supplies ultra-dilute (10 µg/mL) chemical warfare agent (CWA) standards to the Environmental Response Laboratory Network (ERLN) laboratories to allow the use of authentic standards to assist in analyses required for a remediation event involving CWAs. For this reason, it is important to collect data regarding the shelf-lives of these standards. The instability has the potential to impact quality control in regional ERLN laboratories, resulting in data that are difficult to interpret. Thus, this study investigated the use of chemical stabilizers to increase the shelf-life of VX standards. VX standards with long shelf-lives are desirable, as long shelf-life would significantly reduce the costs associated with synthesizing and resupplying the ERLN laboratories with VX.

  9. A plastic dilution refrigerator in a 35 T magnet

    International Nuclear Information System (INIS)

    Oliveira, N.F.Jr; Bindilatti, V.; Haar, E. ter; Martin, R.V.; McNiff, E.J.Jr.

    1996-01-01

    We have built a plastic dilution refrigerator, small enough to fit in the bore of the 35 T hybrid magnet at MIT. The base temperature at H = 0 was 20 mK, measured with a CMN thermometer. In the field, we used capacitive glass thermometers and Matsushita resistors. All data obtained were consistent with a field independent glass thermometer and a negligible magnetoresistance of the Matsushitas at high fields. The minimum temperature measured at 34 T was 25 mK. The effect of magnet vibrations as well as field sweeps (≅ 1 T/min) corresponded to less than 1 μW heating. We observed that, above 29 T, the temperature gradients existent inside the mixing chamber suddenly disappeared, with the temperature becoming homogeneous from top to bottom. We attribute this fact to the effect of the magnetic forces on the liquid. (author)

  10. Mn-AlInN: a new diluted magnetic semiconductor

    International Nuclear Information System (INIS)

    Majid, Abdul; Ali, Akbar; Sharif, Rehana; Zhu, J.J.

    2009-01-01

    Mn ions have been incorporated into MOCVD grown Al 1-x In x N/GaN thin films by ion implantation to achieve the room temperature ferromagnetism in the samples. Magnetic characterizations revealed the presence of two ferromagnetic transitions: one has Curie points at ∝260 K and the other above room temperature. In-diffusion of indium caused by the Mn implantation leads to the partition of AlInN epilayer into two diluted magnetic semiconductor sub-layers depending on the Mn concentration. The Curie temperature of 260 K is assigned to the layer having lower concentration, whereas T c above room temperature is assumed to be associated to the layer having higher Mn concentration. (orig.)

  11. Mn-AlInN: a new diluted magnetic semiconductor

    Energy Technology Data Exchange (ETDEWEB)

    Majid, Abdul; Ali, Akbar [Quaid-i-Azam University, Advance Materials Physics Laboratory, Physics Department, Islamabad (Pakistan); Sharif, Rehana [University of Engineering and Technology, Department of Physics, Lahore (Pakistan); Zhu, J.J. [Chinese Academy of Sciences, State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Beijing (China)

    2009-09-15

    Mn ions have been incorporated into MOCVD grown Al{sub 1-x}In{sub x}N/GaN thin films by ion implantation to achieve the room temperature ferromagnetism in the samples. Magnetic characterizations revealed the presence of two ferromagnetic transitions: one has Curie points at {proportional_to}260 K and the other above room temperature. In-diffusion of indium caused by the Mn implantation leads to the partition of AlInN epilayer into two diluted magnetic semiconductor sub-layers depending on the Mn concentration. The Curie temperature of 260 K is assigned to the layer having lower concentration, whereas T{sub c} above room temperature is assumed to be associated to the layer having higher Mn concentration. (orig.)

  12. Cryogen-free dilution refrigerator for ACTPOL polarization- sensitive receiver

    Science.gov (United States)

    Shvarts, V.; Zhao, Z.; Devlin, M. J.; Klein, J.; Lungu, M.; Schmitt, B.; Thornton, R.

    2014-12-01

    We present a new cryogenic receiver for the Atacama Cosmology Telescope (ACT), a six-meter diameter off-axis Gregorian telescope located at an altitude of 5,200 meters (17,000 ft.) on Cerro Toco, in Northern Chile. The focal plane contains 3000 polarization-sensitive transition edge sensor (TES) bolometers, and is cooled to below 100 mK with a removable pulse-tube based customised JDry-100 dilution refrigerator insert. The optical tubes and the rest of the receiver are cooled with a dedicated pulse tube to below 3 K. Details of the receiver- to-telescope integration and first season on-site operation are described, including detector base temperature stability in vertical and tilted position as well as remote operation via Ethernet link.

  13. Cryogen-free dilution refrigerator for ACTPOL polarization- sensitive receiver

    International Nuclear Information System (INIS)

    Shvarts, V; Zhao, Z; Devlin, M J; Klein, J; Lungu, M; Schmitt, B; Thornton, R

    2014-01-01

    We present a new cryogenic receiver for the Atacama Cosmology Telescope (ACT), a six-meter diameter off-axis Gregorian telescope located at an altitude of 5,200 meters (17,000 ft.) on Cerro Toco, in Northern Chile. The focal plane contains 3000 polarization-sensitive transition edge sensor (TES) bolometers, and is cooled to below 100 mK with a removable pulse-tube based customised JDry-100 dilution refrigerator insert. The optical tubes and the rest of the receiver are cooled with a dedicated pulse tube to below 3 K. Details of the receiver- to-telescope integration and first season on-site operation are described, including detector base temperature stability in vertical and tilted position as well as remote operation via Ethernet link

  14. Dielectric relaxation studies of dilute solutions of amides

    Energy Technology Data Exchange (ETDEWEB)

    Malathi, M.; Sabesan, R.; Krishnan, S

    2003-11-15

    The dielectric constants and dielectric losses of formamide, acetamide, N-methyl acetamide, acetanilide and N,N-dimethyl acetamide in dilute solutions of 1,4-dioxan/benzene have been measured at 308 K using 9.37 GHz, dielectric relaxation set up. The relaxation time for the over all rotation {tau}{sub (1)} and that for the group rotation {tau}{sub (2)} of (the molecules were determined using Higasi's method. The activation energies for the processes of dielectric relaxation and viscous flow were determined by using Eyring's rate theory. From relaxation time behaviour of amides in non-polar solvent, solute-solvent and solute-solute type of molecular association is proposed.

  15. Geochemical detection of carbon dioxide in dilute aquifers

    Directory of Open Access Journals (Sweden)

    Aines Roger

    2009-03-01

    Full Text Available Abstract Background Carbon storage in deep saline reservoirs has the potential to lower the amount of CO2 emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO2 gas leak into dilute groundwater are important measures for the potential release of CO2 to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO2 storage reservoir. Specifically, we address the relationships between CO2 flux, groundwater flow, detection time and distance. The CO2 flux ranges from 103 to 2 × 106 t/yr (0.63 to 1250 t/m2/yr to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure. Results For the scenarios we studied, our simulations show pH and carbonate chemistry are good indicators for leakage of stored CO2 into an overlying aquifer because elevated CO2 yields a more acid pH than the ambient groundwater. CO2 leakage into a dilute groundwater creates a slightly acid plume that can be detected at some distance from the leak source due to groundwater flow and CO2 buoyancy. pH breakthrough curves demonstrate that CO2 leaks can be easily detected for CO2 flux ≥ 104 t/yr within a 15-month time period at a monitoring well screened within a permeable layer 500 m downstream from the vertical gas trace. At lower flux rates, the CO2 dissolves in the aqueous phase

  16. Geochemical detection of carbon dioxide in dilute aquifers.

    Science.gov (United States)

    Carroll, Susan; Hao, Yue; Aines, Roger

    2009-03-26

    Carbon storage in deep saline reservoirs has the potential to lower the amount of CO2 emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO2 gas leak into dilute groundwater are important measures for the potential release of CO2 to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO2 storage reservoir. Specifically, we address the relationships between CO2 flux, groundwater flow, detection time and distance. The CO2 flux ranges from 10(3) to 2 x 10(6) t/yr (0.63 to 1250 t/m2/yr) to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure. For the scenarios we studied, our simulations show pH and carbonate chemistry are good indicators for leakage of stored CO2 into an overlying aquifer because elevated CO2 yields a more acid pH than the ambient groundwater. CO2 leakage into a dilute groundwater creates a slightly acid plume that can be detected at some distance from the leak source due to groundwater flow and CO2 buoyancy. pH breakthrough curves demonstrate that CO2 leaks can be easily detected for CO2 flux >or= 10(4) t/yr within a 15-month time period at a monitoring well screened within a permeable layer 500 m downstream from the vertical gas trace. At lower flux rates, the CO2 dissolves in the aqueous phase in the lower most permeable unit and does

  17. Criteria for the evaluation of a dilute decontamination demonstration

    International Nuclear Information System (INIS)

    FitzPatrick, V.F.; Divine, J.R.; Hoenes, G.R.; Munson, L.F.; Card, C.J.

    1981-12-01

    This document provides the prerequisite technical information required to evaluate and/or develop a project to demonstrate the dilute chemical decontamination of the primary coolant system of light water reactors. The document focuses on five key areas: the basis for establishing programmatic prerequisites and the key decision points that are required for proposal evaluation and/or RFP (Request for Proposal) issuance; a technical review of the state-of-the-art to identify the potential impacts of a reactor's primary-system decontamination on typical BWR and PWR plants; a discussion of the licensing, recertification, fuel warranty, and institutional considerations and processes; a preliminary identification and development of the selection criteria for the reactor and the decontamination process; and a preliminary identification of further research and development that might be required

  18. Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS

    International Nuclear Information System (INIS)

    Fortunato, G.; Wunderli, S.

    2003-01-01

    The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained. This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO 3 /H 2 O 2 microwave digestion. The thallium isotope amount ratio (n( 205 Tl)/n( 203 Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n( 206 Pb)/n( 208 Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study ''lead in wine'' organised by the CCQM (Comite Consultatif pour la Quantite de Matiere, BIPM, Paris; the highest measurement authority for analytical chemical measurements). The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=k x uc, k=2) The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R 206,B of the blend between the enriched spike and the sample. (orig.)

  19. Experimental techniques; Techniques experimentales

    Energy Technology Data Exchange (ETDEWEB)

    Roussel-Chomaz, P. [GANIL CNRS/IN2P3, CEA/DSM, 14 - Caen (France)

    2007-07-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, {gamma} detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  20. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    Science.gov (United States)

    Sugiharto, Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-06-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  1. Self-bound droplets of a dilute magnetic quantum liquid

    Science.gov (United States)

    Schmitt, Matthias; Wenzel, Matthias; Böttcher, Fabian; Ferrier-Barbut, Igor; Pfau, Tilman

    2016-11-01

    Self-bound many-body systems are formed through a balance of attractive and repulsive forces and occur in many physical scenarios. Liquid droplets are an example of a self-bound system, formed by a balance of the mutual attractive and repulsive forces that derive from different components of the inter-particle potential. It has been suggested that self-bound ensembles of ultracold atoms should exist for atom number densities that are 108 times lower than in a helium droplet, which is formed from a dense quantum liquid. However, such ensembles have been elusive up to now because they require forces other than the usual zero-range contact interaction, which is either attractive or repulsive but never both. On the basis of the recent finding that an unstable bosonic dipolar gas can be stabilized by a repulsive many-body term, it was predicted that three-dimensional self-bound quantum droplets of magnetic atoms should exist. Here we report the observation of such droplets in a trap-free levitation field. We find that this dilute magnetic quantum liquid requires a minimum, critical number of atoms, below which the liquid evaporates into an expanding gas as a result of the quantum pressure of the individual constituents. Consequently, around this critical atom number we observe an interaction-driven phase transition between a gas and a self-bound liquid in the quantum degenerate regime with ultracold atoms. These droplets are the dilute counterpart of strongly correlated self-bound systems such as atomic nuclei and helium droplets.

  2. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    International Nuclear Information System (INIS)

    Sugiharto; Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-01-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  3. Large Eddy Simulation for an inherent boron dilution transient

    International Nuclear Information System (INIS)

    Jayaraju, S.T.; Sathiah, P.; Komen, E.M.J.; Baglietto, E.

    2013-01-01

    Highlights: • Large Eddy Simulation is performed for a transient boron dilution scenario in the scaled experimental facility of ROCOM. • Fully conformal polyhedral grid of 14 million is created to capture all details of the domain. • Systematic multi-step validation methodology is followed to assess the accuracy of LES model. • For the presently simulated BDT scenario, the LES results lend support to its reliability in consistently predicting the slug transport in the RPV. -- Abstract: The present paper focuses on the validation and applicability of large eddy simulation (LES) to analyze the transport and mixing in the reactor pressure vessel (RPV) during an inherent boron dilution transient (BDT) scenario. Extensive validation data comes from relevant integral tests performed in the scaled ROCOM experimental facility. The modeling of sub-grid-scales is based on the WALE model. A fully conformal polyhedral grid of about 15 million cells is constructed to capture all details in the domain, including the complex structures of the lower-plenum. Detailed qualitative and quantitative validations are performed by following a systematic multi-step validation methodology. Qualitative comparisons to the experimental data in the cold legs, downcomer and the core inlet showed good predictions by the LES model. Minor deviations seen in the quantitative comparisons are rigorously quantified. A key parameter which is affecting the core neutron kinetics response is the value of highest deborated slug concentration that occurs at the core inlet during the transient. Detailed analyses are made at the core inlet to evaluate not only the value of the maximum slug concentration, but also the location and the time at which it occurs during the transient. The relative differences between the ensemble averaged experimental data and CFD predictions were within the range of relative differences seen within 10 different experimental realizations. For the studied scenario, the

  4. Decomposition of dilute residual active chlorine in sea-water

    International Nuclear Information System (INIS)

    Yoshinaga, Tetsutaro; Kawano, Kentaro; Yanagase, Kenjiro; Shiga, Akira

    1985-01-01

    Coastal industries such as power stations require enormous quantities of sea-water for cooling, but the marine organisms in it often result in fouling and/or blockade of the circulating water condenser and pipeworks. To prevent this, chlorine, or hypochlorite by the direct electrolysis of sea-water have been added. Environmental concerns, however, dictate that the residual chlorine concentration at the outlet should be less than the regulated value (0.02 ppm). Methods for decomposing dilute residual chlorine solutions were therefore studied. It was found that: 1) The addition of (raw) sea-water to the sea-water which passed through the condenser lowered the residual chlorine concentration to an greater extent than could be expected by dilution only. 2) Ozonation of the residual chlorine solution led to degradation of OCl - , but in solutions with a residual chlorine concentrations of less than 3 -- 4 ppm, ozonation had no effect. 3) Irradiation with ultra violet light (254 nm) decomposed the residual chlorine. Under the present work conditions (25 0 C: pH 8; depth 10 mm), nearly first order kinetics were to hold [da/dt = ksub((1)) (1-a)sup(n)]. There is a proportional relationship between the kinetic constant (k) and illuminous intensity (L), i.e., ksub((1))[C 0 sup(Cl 2 ): 10 ppm] = 6.56 x 10 -5 L (L = 0 -- 1000 lx). Thus, the use of both sea-water addition and UV irradiation provides a probable method for decomposing a residual chlorine to the expected concentration. (author)

  5. Redox substoichiometric isotope dilution analysis of metallic arsenic for antimony

    International Nuclear Information System (INIS)

    Kambara, Tomihisa; Yoshioka, Hiroe; Suzuki, Junsuke; Shibata, Yasue.

    1979-01-01

    In 1 M HCl solution Sb(III) reacts with N-benzoyl-N-phenylhydroxylamine (BPHA) to form a complex extractable into chloroform while the extraction of Sb(V) is negligible. The redox substoichiometric isotope dilution analysis based on this reaction was applied to the determination of antimony in metallic arsenic. After the dissolution of metallic arsenic, Sb(V) was separated from As(V) by a tribenzylamine extraction from 8 M HCl solution and the extracted Sb(V) was stripped into 0.5 M NaOH solution. Thereafter, all the Sb(V) were completely reduced to Sb(III) by bubbling SO 2 gas through 3 M HCl solution. As the substoichiometric reaction, the oxidation of Sb(III) to Sb(V) by a substoichiometric amount of potassium dichromate was used, followed by separation of these species by the BPHA extraction of Sb(III). The substoichiometric oxidation of Sb(III) was found to be quantitative over HCl concentration range from 0.8 to 1.2 M. The amount of antimony was determined by isotope dilution analysis using the method of carrier amount variation. By the present method the determination of as small as 0.36 μg antimony was accomplished with a good accuracy (relative error; 5.6%) and also the method was successfully applied to the determination of antimony in arsenic samples containing known amounts of Sb(III) and in metallic arsenic. The present method gives reliable results with the good accuracy and precision. (author)

  6. Some local dilution transient in a pressurized water reactor

    International Nuclear Information System (INIS)

    Jacobson, S.

    1989-01-01

    Reactivity accidents are important in the safety analysis of a pressurized water reactor. In this anlysis ejected control rod, steam line break, start of in-active loop and boron dilution accidents are usually dealt with. However, in the analysis is not included what reactivity excursions might happen when a zone,depleted of boron passes the reactor core. This thesis investigates during what operation and emergency conditions diluted zones might exist in a pressurized water reactor and what should be the maximum volumes for then. The limiting transport means are also established in terms of reactivty addition, for the depleted zones. In order to describe the complicated mixing process in the reactor vessel during such a transportation, a typical 3-loop reactor vessel has been modulated by means of TRAC-PF1's VESSEL component. Three cases have been analysed. In the first case the reactor is in a cold condition and the ractor coolant has boron concentration of 2000 ppm. To the reactor vessel is injected an clean water colume of 14 m 3 . In the two other cases the reactor is close to hot shutdown and borated to 850 ppm. To the reactor vessel is added 41 and 13 m 3 clean water, respectively. In the thesis is shown what spatial distribution the depleted zone gets when passing through the reactor vessel in the three cases. The boron concentration in the first case did not decrease the values which would bring the reactor to critical condition. For case two was shown by means of TRAC's point kinetics model that the reactor reaches prompt criticality after 16.03 seconds after starting of the reactor coolant pump. Another prompt criticality occured two seconds later. The total energy developed during the two power escalations were about 55 GJ. A comparision with the criteria used to evaluate the ejected control rod reactivity transient showed that none of these criteria were exceeded. (64 figs.)

  7. Isotope correlation and mass spectrometry techniques for irradiated fuel assay

    International Nuclear Information System (INIS)

    Deron, S.

    1985-01-01

    This paper outlines the methods used to account for fissionable materials in irradiated nuclear fuel elements entering reprocessing plants. Verification is accomplished at three mass balance stations in the plant. Techniques employed fall into two categories: isotopic and isotope dilution analyses by mass spectometry and isotope correlation techniques. These methods are discussed in some detail

  8. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  9. Effects of diluting medium and holding time on sperm motility analysis by CASA in ram

    Directory of Open Access Journals (Sweden)

    Somayeh Mostafapor

    2014-06-01

    Full Text Available The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA. The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP, phosphate-buffered saline (PBS containing 1% bovine serum albumin (BSA and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL, straight line velocity (VSL, average path velocity (VAP, straightness (STR, linearity (LIN, amplitude of lateral head displacement (ALH, and beat cross frequency (BCF. In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.

  10. Effects of diluting medium and holding time on sperm motility analysis by CASA in ram.

    Science.gov (United States)

    Mostafapor, Somayeh; Farrokhi Ardebili, Farhad

    2014-01-01

    The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA). The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP), phosphate-buffered saline (PBS) containing 1% bovine serum albumin (BSA) and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP), straightness (STR), linearity (LIN), amplitude of lateral head displacement (ALH), and beat cross frequency (BCF). In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.

  11. Studies on the dilution behaviour of effluent discharged into the CCW channel at KGS

    International Nuclear Information System (INIS)

    Sivasubramanian, K.; Srinivasan, S.; Ponraju, D.; Meenakshisundaram, V.; Munusamy, N.

    2003-01-01

    The dilution behaviour of the liquid effluent discharged into condenser cooling water channel of Kaiga Power Plant has been studied using salt addition and dye addition methods. Dilution factors determined experimentally showed that the discharged liquid effluent gets thoroughly mixed with stream of water at the weir and further diluted in the down stream. This paper describes both salt and dye addition methods for determining the dilution factor. The velocity of the stream at various locations were measured and compared with reported values. The selection of representative sampling point for routine analysis of water was identified from this experiment. (author)

  12. Optimal sample to tracer ratio for isotope dilution mass spectrometry: the polyisotopic case

    International Nuclear Information System (INIS)

    Laszlo, G.; Ridder, P. de; Goldman, A.; Cappis, J.; Bievre, P. de

    1991-01-01

    The Isotope Dilution Mass Spectrometry (IDMS) measurement technique provides a means for determining the unknown amount of various isotopes of an element in a sample solution of known mass. The sample solution is mixed with an auxiliary solution, or tracer, containing a known amount of the same element having the same isotopes but of different relative abundances or isotopic composition and the induced change in the isotopic composition measured by isotope mass spectrometry. The technique involves the measurement of the abundance ratio of each isotope to a (same) reference isotope in the sample solution, in the tracer solution and in the blend of the sample and tracer solution. These isotope ratio measurements, the known element amount in the tracer and the known mass of sample solution are used to calculate the unknown amount of one isotope in the sample solution. Subsequently the unknown amount of element is determined. The purpose of this paper is to examine the optimization of the ratio of the estimated unknown amount of element in the sample solution to the known amount of element in the tracer solution in order to minimize the relative uncertainty in the determination of the unknown amount of element

  13. A model for the viscosity of dilute smectite gels

    International Nuclear Information System (INIS)

    Liu, Di; Liu, Longcheng

    2010-01-01

    Document available in extended abstract form only. A simple yet accurate model describing the viscosity of dilute suspensions of sodium montmorillonite in low ionic strength waters is presented. Taking the clay particle and the surrounding clouds of ions as whole as an uncharged but soft particle, the Huggins' equation is extended in the model to account for both the primary and the secondary electro-viscous effects, by use of the notion of an effective volume fraction. In the model, however, we do not represent the clay particle as a sphere surrounded by immobile water layer with thickness of a Debye length, as did by Adachi et al. (1998) who used the co-volume fraction to approximate the effective volume fraction. We visualize the effective geometry of the particle and the associated ionic atmosphere as an ellipsoid. This representation is more practical and more plausible, because in the limit of large ionic strength, the electrolyte ions have been screened to a significant extent so that the charged particle behaves just like an uncharged one. As a result, the application of the Simha's equation of intrinsic viscosity for ellipsoidal particle following with random Brownian motion enables us to obtain an analytical expression for the primary electro-viscous effect. More importantly, the available models for hard plate-like particles can be used to aid in the quantification of the secondary electro-viscous effect. The development of the model is based firmly on precise measurements of the viscosity of sufficiently dilute suspensions of sodium montmorillonite in low concentration NaCl solutions (at room temperature) using Ostwald capillary viscometers. The obtained data clearly demonstrate the primary and the secondary electro-viscous effects. That is, with an decrease of ionic strength, the intrinsic viscosity which is the intercept of the extrapolation of the plot at zero volume fraction will increase, and the slope of the linear part which appears in

  14. Heat Transfer in Boiling Dilute Emulsion with Strong Buoyancy

    Science.gov (United States)

    Freeburg, Eric Thomas

    Little attention has been given to the boiling of emulsions compared to that of boiling in pure liquids. The advantages of using emulsions as a heat transfer agent were first discovered in the 1970s and several interesting features have since been studied by few researchers. Early research focuses primarily on pool and flow boiling and looks to determine a mechanism by which the boiling process occurs. This thesis looks at the boiling of dilute emulsions in fluids with strong buoyant forces. The boiling of dilute emulsions presents many favorable characteristics that make it an ideal agent for heat transfer. High heat flux electronics, such as those seen in avionics equipment, produce high heat fluxes of 100 W/cm2 or more, but must be maintained at low temperatures. So far, research on single phase convection and flow boiling in small diameter channels have yet to provide an adequate solution. Emulsions allow the engineer to tailor the solution to the specific problem. The fluid can be customized to retain the high thermal conductivity and specific heat capacity of the continuous phase while enhancing the heat transfer coefficient through boiling of the dispersed phase component. Heat transfer experiments were carried out with FC-72 in water emulsions. FC-72 has a saturation temperature of 56 °C, far below that of water. The parameters were varied as follows: 0% ≤ epsilon ≤ 1% and 1.82 x 1012 ≤ RaH ≤ 4.42 x 1012. Surface temperatures along the heated surface reached temperature that were 20 °C in excess of the dispersed phase saturation temperature. An increase of ˜20% was seen in the average Nusselt numbers at the highest Rayleigh numbers. Holography was used to obtain images of individual and multiple FC-72 droplets in the boundary layer next to the heated surface. The droplet diameters ranged from 0.5 mm to 1.3 mm. The Magnus effect was observed when larger individual droplets were injected into the boundary layer, causing the droplets to be pushed

  15. The IDA-80 measurement evaluation programme on mass spectrometric isotope dilution analysis of uranium and plutonium. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Golly, W.; Spannagel, G.; Kernforschungszentrum Karlsruhe G.m.b.H.; Bievre, P. de; Wolters, W.

    1984-12-01

    The main objective was the acquisition of basic data on the uncertainties involved in the mass spectrometric isotope dilution analysis as applied to the determination of uranium and plutonium in active feed solutions of reprocessing plants. The element concentrations and isotopic compositions of all test materials used were determined by CBNM and NBS with high accuracy. The more than 60000 analytical data reported by the participating laboratories were evaluated by statistical methods applied mainly to the calculation of estimates of the variances for the different uncertainty components contributing to the total uncertainty of this analytical technique. Attention was given to such topics as sample ageing, influence of fission products, spike calibration, ion fractionation, Pu-241 decay correction, minor isotope measurement and errors in data transfer. Furthermore, the performance of the 'dried sample' technique and the 'in-situ' spiking method of undiluted samples of reprocessing fuel solution with U-235/Pu-242 metal alloy spikes, were tested successfully. Considerable improvement of isotope dilution analysis in this safeguards relevant application during the last decade is shown as compared to the results obtained in the IDA-72 interlaboratory experiment, organized by KfK in 1972 on the same subject. (orig./HP) [de

  16. Activity coefficients at infinite dilution of hydrocarbons in glycols: Experimental data and thermodynamic modeling with the GCA-EoS

    International Nuclear Information System (INIS)

    González Prieto, Mariana; Williams-Wynn, Mark D.; Bahadur, Indra; Sánchez, Francisco A.; Mohammadi, Amir H.

    2017-01-01

    Highlights: • Experimental infinite dilution activity coefficients of hydrocarbons in glycols. • Inverse gas-liquid chromatography technique. • Solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. • Highly non-ideal systems are modeled with the GCA-EoS. - Abstract: The infinite dilution activity coefficients for 12 non-polar hydrocarbon solutes in the solvents, monoethylene and diethylene glycol, were measured using the gas-liquid chromatography technique. Pre-saturation of the carrier gas was required to avoid solvent loss from the chromatographic column during the measurements that were carried out at T = (303.15, 313.15 and 323.15) K for monoethylene glycol and at T = (304.15, 313.15 and 323.15) K for diethylene glycol. The solutes investigated include n-alkanes, 1-alkenes, and cycloalkanes. The new data are compared with the highly scattered data that is available in the open literature. Finally, these highly non-ideal systems are modeled with the GCA-EoS.

  17. Quantitation of DNA adducts by stable isotope dilution mass spectrometry

    Science.gov (United States)

    Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory

    2012-01-01

    Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593

  18. Gas Leak Detection by Dilution of Atmospheric Oxygen

    Directory of Open Access Journals (Sweden)

    Armin Lambrecht

    2017-12-01

    Full Text Available Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.

  19. Removal of actinides from dilute waste waters using polymer filtration

    International Nuclear Information System (INIS)

    Smith, B.F.; Robison, T.W.; Gibson, R.R.

    1995-01-01

    More stringent US Department of Energy discharge regulations for waste waters containing radionuclides (30 pCi/L total alpha) require the development of new processes to meet the new discharge limits for actinide metal ions, particularly americium and plutonium, while minimizing waste. We have been investigating a new technology, polymer filtration, that has the potential for effectively meeting these new limits. Traditional technology uses basic iron precipitation which produces large amounts of waste sludge. The new technology is based on using water-soluble chelating polymers with ultrafiltration for physical separation. The actinide metal ions are selectively bound to the polymer and can not pass through the membrane. Small molecules and nonbinding metals pass through the membrane. Advantages of polymer filtration technology compared to ion, exchange include rapid kinetics because the binding is occurring in a homogenous solution and no mechanical strength requirement on the polymer. We will present our results on the systematic development of a new class of water-soluble chelating polymers and their binding ability from dilute acid to near neutral waters

  20. A scanning tunneling microscope for a dilution refrigerator.

    Science.gov (United States)

    Marz, M; Goll, G; Löhneysen, H v

    2010-04-01

    We present the main features of a home-built scanning tunneling microscope that has been attached to the mixing chamber of a dilution refrigerator. It allows scanning tunneling microscopy and spectroscopy measurements down to the base temperature of the cryostat, T approximately 30 mK, and in applied magnetic fields up to 13 T. The topography of both highly ordered pyrolytic graphite and the dichalcogenide superconductor NbSe(2) has been imaged with atomic resolution down to T approximately 50 mK as determined from a resistance thermometer adjacent to the sample. As a test for a successful operation in magnetic fields, the flux-line lattice of superconducting NbSe(2) in low magnetic fields has been studied. The lattice constant of the Abrikosov lattice shows the expected field dependence proportional to 1/square root of B and measurements in the scanning tunneling spectroscopy mode clearly show the superconductive density of states with Andreev bound states in the vortex core.

  1. Nonequilibrium thermodynamics of dilute polymer solutions in flow.

    Science.gov (United States)

    Latinwo, Folarin; Hsiao, Kai-Wen; Schroeder, Charles M

    2014-11-07

    Modern materials processing applications and technologies often occur far from equilibrium. To this end, the processing of complex materials such as polymer melts and nanocomposites generally occurs under strong deformations and flows, conditions under which equilibrium thermodynamics does not apply. As a result, the ability to determine the nonequilibrium thermodynamic properties of polymeric materials from measurable quantities such as heat and work is a major challenge in the field. Here, we use work relations to show that nonequilibrium thermodynamic quantities such as free energy and entropy can be determined for dilute polymer solutions in flow. In this way, we determine the thermodynamic properties of DNA molecules in strong flows using a combination of simulations, kinetic theory, and single molecule experiments. We show that it is possible to calculate polymer relaxation timescales purely from polymer stretching dynamics in flow. We further observe a thermodynamic equivalence between nonequilibrium and equilibrium steady-states for polymeric systems. In this way, our results provide an improved understanding of the energetics of flowing polymer solutions.

  2. Static and dynamic light scattering studies on dilute polyrotaxane solutions

    Science.gov (United States)

    Kume, Tetsuya; Araki, Jun; Sakai, Yasuhiro; Mayumi, Koichi; Kidowaki, Masatoshi; Yokoyama, Hideaki; Ito, Kohzo

    2009-08-01

    Static and dynamic light scattering measurements were performed for dilute polyrotaxane solutions in different types of solvent systems, i.e. dimethylacetamide (DMAc) or dimethylformamide (DMF) containing 1-6 wt% lithium chloride (LiCl), 1 M aqueous sodium hydroxide (NaOH) and dimethylsulfoxide (DMSO). No aggregation of the polyrotaxane in DMF/LiCl was confirmed in the present study. Radius of gyration of the dissolved polyrotaxane was largest in NaOHaq., followed by values in amide solvents/LiCl and that in DMSO, and was probably dominated not by Coulombic repulsion but by the mutual affinity between solvent and polyrotaxane. Ratio of radius of gyration to hydrodynamic radius suggested the flexible random-coiled conformation in DMSO and relatively more extended, semi-flexible ones in amide solvents/LiCl and NaOHaq. The obtained values of second virial coefficient and weight average molecular weight seemed to be affected by a potential change in differential refractive index increments, caused by selective macrocationization or ionization.

  3. Agar dilution method for susceptibility testing of Neisseria gonorrhoeae

    Directory of Open Access Journals (Sweden)

    Marta C de Castillo

    1996-12-01

    Full Text Available The antibiotic susceptibilities of Neisseria gonorrhoeae isolates obtained from patients attending a clinic for sexually transmitted diseases in Tucumán, Argentina, were determined by the agar dilution method (MIC. 3.5% of the isolates produced ²-lactamase. A total of 96.5% of ²-lactamase negative isolates tested were susceptible to penicillin (MIC < 2 µgml-1; 14.03% of the tested isolates were resistant to tetracycline (MIC < 2 µgml-1, and 98% of the tested isolates were susceptible to spectinomycin (MIC < 64 µgml-1. The MICs for 95% of the isolates, tested for other drugs were: < 2 µgml-1 for cefoxitin, < 0.06 µgml-1 for cefotaxime, < 0.25 µgml-1 for norfloxacin, < 10 µgml-1 for cephaloridine, < 10 µgml-1 for cephalexin, and < 50 µgml-1 for kanamycin. Antibiotic resistance among N. gonorrhoeae isolates from Tucumán, Argentina, appeared to be primarily limited to penicillin and tetracycline, which has been a general use against gonorrhoeae in Tucumán since 1960. Periodic monitoring of the underlying susceptibility profiles of the N. gonorrhoeae strains prevalent in areas of frequent transmission may provide clues regarding treatment options and emerging of drug resistance.

  4. Dermal absorption of a dilute aqueous solution of malathion

    Directory of Open Access Journals (Sweden)

    Scharf John

    2008-01-01

    Full Text Available Malathion is an organophosphate pesticide commonly used on field crops, fruit trees, livestock, agriculture, and for mosquito and medfly control. Aerial applications can result in solubilized malathion in swimming pools and other recreational waters that may come into contact with human skin. To evaluate the human skin absorption of malathion for the assessment of risk associated with human exposures to aqueous solutions, human volunteers were selected and exposed to aqueous solutions of malathion. Participants submerged their arms and hands in twenty liters of dilute malathion solution in either a stagnant or stirred state. The "disappearance method" was applied by measuring malathion concentrations in the water before and after human exposure for various periods of time. No measurable skin absorption was detected in 42% of the participants; the remaining 58% of participants measured minimal absorbed doses of malathion. Analyzing these results through the Hazard Index model for recreational swimmer and bather exposure levels typically measured in contaminated swimming pools and surface waters after bait application indicated that these exposures are an order of magnitude less than a minimal dose known to result in a measurable change in acetylcholinesterase activity. It is concluded that exposure to aqueous malathion in recreational waters following aerial bait applications is not appreciably absorbed, does not result in an effective dose, and therefore is not a public health hazard.

  5. Gamma-radiolysis of some glycoproteins in dilute aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Nagrani, S

    1981-01-01

    A study has been made of the radiation-induced damage of some glycoproteins in dilute aqueous solutions. By use of specific radical scavengers, the roles of the individual free radicals, formed by ..gamma..-radiolysis, in causing damage has been assessed. The most effective radical in causing damage to human and porcine glycopolypeptide is the OH radical. The structure of the different blood group glycopolypeptides determines the sensitivity towards the free radical attack. The glycopolypeptide shows depolymerization and a characteristic absorption at approximately 270 nm due to the formation of additional products on irradiation. Chemical changes of the irradiated glycopolypeptide solutions revealed significant damage to the oligosaccharide chain and the polypeptide core of the glycopolypeptide. The radiation-induced inactivation of another glycoprotein, external yeast invertase, due to different radical species at pH 7.0 decreases in the following order: ea-barq > OH radical > (SCN) radical/sub 2//sup -/ > Br radical/sub 2//sup -/. The structure of this enzyme, accounts for the mechanism of enzyme inactivation and the relative damage of carbohydrate and amino acid residues. The irradiated enzyme solutions show significant changes in their electrophoretic behaviour on cellogel electrophoresis due to the formation of radiolysis products, which also show characteristic absorption maxima at approximately 275 nm. (author).

  6. Rare isotopes and the sound of dilute nuclear matter

    Science.gov (United States)

    Papakonstantinou, P.

    2018-04-01

    Dilute baryonic matter, at densities below the normal saturation density of symmetric matter, is found on the crust of neutron stars and in collapsing supernova matter, its properties determining the evolution of those stellar objects. It is also readily found on the surface of ordinary and exotic atomic nuclei and lives fleetingly in the form of space-extended resonances of excited nucleons. Liminal states of nuclear matter, between saturation and full evaporation or clusterization, are manifest in the structure of symmetric nuclei through clustering and of very asymmetric rare species in haloes and the neutron skin; they stand literally at the threshold of a nucleus's response to hadronic probes, including processes which hinder or enable fusion. In this contribution I focus on excited states, and in particular exotic or not-so-exotic dipole excitation modes of N = Z nuclei and neutron-rich species, including new theoretical results on threshold strength. Modes of special interest are vibrations of and within diffuse surface layers and alpha-cluster oscillations. The modeling of such processes is relevant, directly or indirectly, for the description of reactions at astrophysical energies.

  7. Weighted Geometric Dilution of Precision Calculations with Matrix Multiplication

    Directory of Open Access Journals (Sweden)

    Chien-Sheng Chen

    2015-01-01

    Full Text Available To enhance the performance of location estimation in wireless positioning systems, the geometric dilution of precision (GDOP is widely used as a criterion for selecting measurement units. Since GDOP represents the geometric effect on the relationship between measurement error and positioning determination error, the smallest GDOP of the measurement unit subset is usually chosen for positioning. The conventional GDOP calculation using matrix inversion method requires many operations. Because more and more measurement units can be chosen nowadays, an efficient calculation should be designed to decrease the complexity. Since the performance of each measurement unit is different, the weighted GDOP (WGDOP, instead of GDOP, is used to select the measurement units to improve the accuracy of location. To calculate WGDOP effectively and efficiently, the closed-form solution for WGDOP calculation is proposed when more than four measurements are available. In this paper, an efficient WGDOP calculation method applying matrix multiplication that is easy for hardware implementation is proposed. In addition, the proposed method can be used when more than exactly four measurements are available. Even when using all-in-view method for positioning, the proposed method still can reduce the computational overhead. The proposed WGDOP methods with less computation are compatible with global positioning system (GPS, wireless sensor networks (WSN and cellular communication systems.

  8. Dissociation of dilute immiscible copper alloy thin films

    International Nuclear Information System (INIS)

    Barmak, K.; Lucadamo, G. A.; Cabral, C. Jr.; Lavoie, C.; Harper, J. M. E.

    2000-01-01

    The dissociation behavior of dilute, immiscible Cu-alloy thin films is found to fall into three broad categories that correlate most closely with the form of the Cu-rich end of the binary alloy phase diagrams. Available thermodynamic and tracer diffusion data shed further light on alloy behavior. Eight alloying elements were selected for these studies, with five elements from groups 5 and 6, two from group 8, and one from group 11 of the periodic table. They are respectively V, Nb, Ta, Cr, Mo, Fe, Ru, and Ag. The progress of precipitation in approximately 500-nm-thick alloy films, containing 2.5-3.8 at. % solute, was followed with in situ resistance and stress measurements as well as with in situ synchrotron x-ray diffraction. In addition, texture analysis and transmission electron microscopy were used to investigate the evolution of microstructure and texture of Cu(Ta) and Cu(Ag). For all eight alloys, dissociation occurred upon heating, with the rejection of solute and evolution of microstructure often occurring in multiple steps that range over several hundred degrees between approximately 100 and 900 degree sign C. However, in most cases, substantial reductions in resistivity of the films took place below 400 degree sign C, at temperatures of interest to copper metallization schemes for silicon chip technology. (c) 2000 American Institute of Physics

  9. Static and dynamic light scattering studies on dilute polyrotaxane solutions

    International Nuclear Information System (INIS)

    Kume, Tetsuya; Sakai, Yasuhiro; Mayumi, Koichi; Kidowaki, Masatoshi; Yokoyama, Hideaki; Ito, Kohzo; Araki, Jun

    2009-01-01

    Static and dynamic light scattering measurements were performed for dilute polyrotaxane solutions in different types of solvent systems, i.e. dimethylacetamide (DMAc) or dimethylformamide (DMF) containing 1-6 wt% lithium chloride (LiCl), 1 M aqueous sodium hydroxide (NaOH) and dimethylsulfoxide (DMSO). No aggregation of the polyrotaxane in DMF/LiCl was confirmed in the present study. Radius of gyration of the dissolved polyrotaxane was largest in NaOHaq., followed by values in amide solvents/LiCl and that in DMSO, and was probably dominated not by Coulombic repulsion but by the mutual affinity between solvent and polyrotaxane. Ratio of radius of gyration to hydrodynamic radius suggested the flexible random-coiled conformation in DMSO and relatively more extended, semi-flexible ones in amide solvents/LiCl and NaOHaq. The obtained values of second virial coefficient and weight average molecular weight seemed to be affected by a potential change in differential refractive index increments, caused by selective macrocationization or ionization.

  10. Automated spike preparation system for Isotope Dilution Mass Spectrometry (IDMS)

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1990-01-01

    Isotope Dilution Mass Spectrometry (IDMS) is a method frequently employed to measure dissolved, irradiated nuclear materials. A known quantity of a unique isotope of the element to be measured (referred to as the ''spike'') is added to the solution containing the analyte. The resulting solution is chemically purified then analyzed by mass spectrometry. By measuring the magnitude of the response for each isotope and the response for the ''unique spike'' then relating this to the known quantity of the ''spike'', the quantity of the nuclear material can be determined. An automated spike preparation system was developed at the Savannah River Site (SRS) to dispense spikes for use in IDMS analytical methods. Prior to this development, technicians weighed each individual spike manually to achieve the accuracy required. This procedure was time-consuming and subjected the master stock solution to evaporation. The new system employs a high precision SMI Model 300 Unipump dispenser interfaced with an electronic balance and a portable Epson HX-20 notebook computer to automate spike preparation

  11. Irradiation-induced patterning in dilute Cu–Fe alloys

    International Nuclear Information System (INIS)

    Stumphy, B.; Chee, S.W.; Vo, N.Q.; Averback, R.S.; Bellon, P.; Ghafari, M.

    2014-01-01

    Compositional patterning in dilute Cu 1−x Fe x (x ≈ 12%) induced by 1.8 MeV Kr + irradiation was studied as a function of temperature using atom probe tomography. Irradiation near room temperature led to homogenization of the sample, whereas irradiation at 300 °C and above led to precipitation and macroscopic coarsening. Between these two temperatures the irradiated alloys formed steady state patterns of composition where precipitates grew to a fixed size. The size in this regime increased somewhat with temperature. It was also observed that the steady state concentrations of Fe in Cu matrix and Cu in the Fe precipitates both greatly exceeded their equilibrium solubilities, with the degree of supersaturation in each phase decreasing with increasing temperature. In the macroscopic coarsening regime, the Fe-rich precipitates showed indications of a “cherry-pit” structure, with Cu precipitates forming within the Fe precipitates. In the patterning regime, interfaces between Fe-rich precipitates and the Cu-rich matrix were irregular and diffuse

  12. Forward di-jet production in dilute-dense collisions

    Directory of Open Access Journals (Sweden)

    Petreska E.

    2016-01-01

    Full Text Available We derive a factorization formula for forward production of two jets in dilutedense collisions that is valid for an arbitrary value of the momentum imbalance of the jets, kt. This generalizes the transverse momentum dependent (TMD factorization formula that has been derived before by Dominguez et al. Their formula is valid only for small values of the transverse momentum of the small-x gluon from the target; it has kt dependent TMD gluon distributions, but on-shell hard matrix elements. We extend the TMD formula to all ranges of kt by including off-shell matrix elements. We also add finite Nc corrections. The new formula encompasses both, the TMD factorization for small kt on the order of the saturation scale, and the High Energy Factorization (HEF for large kt on the order of the momentum of the jets. The TMD and HEF factorizations can be derived from the Color Glass Condensate (CGC formula for forward di-jet production in the appropriate limits. We show explicitly the equivalence of HEF and CGC in the dilute target approximation.

  13. Tunable spin waves in diluted magnetic semiconductor nanoribbon

    Science.gov (United States)

    Lyu, Pin; Zhang, Jun-Yi

    2018-01-01

    The spin wave excitation spectrum in diluted magnetic semiconductor (DMS) nanoribbons was calculated by taking account of the quantum confinement effect of carriers and spin waves. By introducing the boundary condition for the spin waves, we derived the spin wave dispersion using the path-integral formulation and Green's function method. It was shown that the spin wave excitation spectrum is discrete due to the confinement effect and strongly dependent on the carrier density, the magnetic ion density, and the width of the nanoribbon. When the width of the nanoribbon is beyond the typical nanoscales, the size effect on the excitation energies of the spin waves disappears in our calculation, which is in qualitative agreement with no obvious size effect observed in the as-made nanodevices of (Ga,Mn)As in this size regime. Our results provide a potential way to control the spin waves in the DMS nanoribbon not only by the carrier density and the magnetic ion density but also by the nanostructure geometry.

  14. Ab-initio calculations for dilute magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Belhadji, Brahim

    2008-03-03

    This thesis focusses on ab-initio calculations for the electronic structure and the magnetic properties of dilute magnetic semiconductors (DMS). In particular we aim at the understanding of the complex exchange interactions in these systems. Our calculations are based on density functional theory, being ideally suited for a description of the material specific properties of the considered DMS. Moreover we use the KKR Green function method in connection with the coherent potential approximation (CPA), which allows to include the random substitutional disorder in a mean field-like approximation for the electronic structure. Finally we calculate the exchange coupling constants J{sub ij} between two impurities in a CPA medium by using the Lichtenstein formula and from this calculate the Curie temperature by a numerically exact Monte Carlo method. Based on this analysis we found and investigated four different exchange mechanisms being of importance in DMS systems: Double exchange, p-d exchange, antiferromagnetic superexchanges, and ferromagnetic superexchange. A second topic we have investigated in this thesis is the pressure dependence of the exchange interactions and the Curie temperatures in (Ga,Mn)As and (In,Mn)As, using the LDA and the LDA+U approximations. Exact calculations of T{sub C} by Monte Carlo simulations show a somehow different behavior. (orig.)

  15. Magnetoviscous effect in ferrofluids diluted with sheep blood

    Science.gov (United States)

    Nowak, J.; Borin, D.; Haefner, S.; Richter, A.; Odenbach, S.

    2017-11-01

    Suspensions of magnetic nanoparticles in suitable carrier liquids, denoted as ferrofluids, are in the focus of current research in the biomedical area. Those fluids can be potentially used for the treatment of cancer by coupling chemotherapeutic agents and accumulating them in the diseased region with the help of external magnetic fields or by artificially local induced heating. Those applications rely on the help of external magnetic fields, which are well known to drastically influence the physical behaviour of ferrofluids. This study investigates the changing viscosity of a biocompatible ferrofluid in a flow situation close to the situation found in a biomedical application. For this purpose blood as diluting agent and thin capillaries have been utilised. The strong magnetoviscous effects found lead to the assumption of quite big changes of the microstructure due to the external magnetic fields, which was investigated and quantified using a microscopic setup. In the result an increases of the structure size as well as faster structure formation in the stronger magnetic fields were observed. Moreover, with increasing duration of the applied magnetic field the size of the structures increases too. The observed process of the structure formation is reversible.

  16. Rheology and microstructure of dilute graphene oxide suspension

    International Nuclear Information System (INIS)

    Tesfai, Waka; Singh, Pawan; Shatilla, Youssef; Iqbal, Muhammad Z.; Abdala, Ahmed A.

    2013-01-01

    Graphene and graphene oxide are potential candidates as nanofluids for thermal management applications. Here, we investigate the rheological properties and intrinsic viscosity of aqueous suspension of graphene and use the measured intrinsic viscosity to determine the aspect ratio of graphene oxide. Dilute suspension of graphene oxide (0.05 to 0.5 mg/mL) exhibits a shear thinning behavior at low shear rates followed by a shear-independent region that starts at shear rate between 5 and 100/s depending on the concentration. This shear thinning behavior becomes more pronounced with the increase of particle loading. Moreover, AFM imaging of the dried graphene oxide indicates the evolution of irregular and thin low fractal aggregates of 0.3–1.8 nm thickness at lower concentrations to oblate compact structures of 1–18 nm thickness of nanosheets at higher concentration. These observations elucidate the microstructure growth mechanisms of graphene oxide in multiphase systems, which are important for nanofluids applications and for dispersing graphene and graphene oxide in composite materials. The suspension has a very high intrinsic viscosity of 1661 due to the high graphene oxide aspect ratio. Based on this intrinsic viscosity, we predict graphene oxide aspect ratio of 2445. While the classical Einstein and Batchelor models underestimate the relative viscosity of graphene oxide suspension, Krieger–Dougherty prediction is in a good agreement with the experimental measurement

  17. Nuclear magnetic resonance of randomly diluted magnetic materials

    International Nuclear Information System (INIS)

    Magon, C.J.

    1985-01-01

    The temperature dependence of the nuclear relaxation rates and line shapes of the F O resonance in the diluted antiferromagnet Fe x Zn 1-x F 2 and Mn x Zn 1-x F 2 are studied over a large temperature range T N 1 ) of the F O nuclei, which are not transfer hyperfine coupled to the Fe (or Mn) spins, have been measured and calculated as a function of the concentration x. Good agreement with experiment is found for the theoretical results, which have been obtained in the range 0.1 ≤ x ≤ 0.8. The temperature dependence of 1/T 1 for T N 1 data near T N was used to study Random Field Effects on the critical behavior of Mn .65 Zn . 3 5 F 2 , for fields applied parallel and perpendicular to the easy (C) axis. It was found that the transition temperature T N depressed substantially with field only for H o || C. The experimental results are in general accord with the theory for Random Field Effects in disordered, anisotropic antiferromagnets. The critical divergence of the inhomogeneously broadened F O NMR was studied in Fe .6 Zn .4 F 2 above T N . The experimental results agree with Heller's calculation of the NMR line broadening by Random Field Effects. With H o || C the line shape changes from Gaussian towards Lozentzian for t -2 and below T N its line width increase qualitatively following the increase in the sublattice magnetization. (author)

  18. Conformation of ionizable poly Para phenylene ethynylene in dilute solutions

    International Nuclear Information System (INIS)

    Wijesinghe, Sidath; Maskey, Sabina; Perahia, Dvora; Grest, Gary S.

    2015-01-01

    The conformation of dinonyl poly para phenylene ethynylenes (PPEs) with carboxylate side chains, equilibrated in solvents of different quality is studied using molecular dynamics simulations. PPEs are of interest because of their tunable electro-optical properties, chemical diversity, and functionality which are essential in wide range of applications. The polymer conformation determines the conjugation length and their assembly mode and affects electro-optical properties which are critical in their current and potential uses. The current study investigates the effect of carboxylate fraction on PPEs side chains on the conformation of chains in the dilute limit, in solvents of different quality. The dinonyl PPE chains are modeled atomistically, where the solvents are modeled both implicitly and explicitly. Dinonyl PPEs maintained a stretched out conformation up to a carboxylate fraction f of 0.7 in all solvents studied. The nonyl side chains are extended and oriented away from the PPE backbone in toluene and in implicit good solvent whereas in water and implicit poor solvent, the nonyl side chains are collapsed towards the PPE backbone. Thus, rotation around the aromatic ring is fast and no long range correlations are seen within the backbone

  19. Dilute Nitrides For 4-And 6- Junction Space Solar Cells

    Science.gov (United States)

    Essig, S.; Stammler, E.; Ronsch, S.; Oliva, E.; Schachtner, M.; Siefer, G.; Bett, A. W.; Dimroth, F.

    2011-10-01

    According to simulations the efficiency of conventional, lattice-matched GaInP/GaInAs/Ge triple-junction space solar cells can be strongly increased by the incorporation of additional junctions. In this way the existing excess current of the Germanium bottom cell can be reduced and the voltage of the stack can be increased. In particular, the use of 1.0 eV materials like GaInNAs opens the door for solar cells with significantly improved conversion efficiency. We have investigated the material properties of GaInNAs grown by metal organic vapour phase epitaxy (MOVPE) and its impact on the quantum efficiency of solar cells. Furthermore we have developed a GaInNAs subcell with a bandgap energy of 1.0 eV and integrated it into a GaInP/GaInAs/GaInNAs/Ge 4-junction and a AlGaInP/GaInP/AlGaInAs/GaInAs/GaInNAs/Ge 6- junction space solar cell. The material quality of the dilute nitride junction limits the current density of these devices to 9.3 mA/cm2 (AM0). This is not sufficient for a 4-junction cell but may lead to current matched 6- junction devices in the future.

  20. The solidification behavior of dilute aluminium-scandium alloys

    International Nuclear Information System (INIS)

    Norman, A.F.; Prangnell, P.B.; McEwen, R.S.

    1998-01-01

    The solidification behavior of dilute Sc containing Al alloys has been investigated. In binary Al-Sc alloys, Sc additions greater than the eutectic composition (0.55 wt%) were found to produce a remarkable refinement in the grain size of aluminum castings, of two orders of magnitude, due to the formation of the primary Al 3 Sc intermetallic phase during solidification. The refinement in grain size only occurred in hypereutectic compositions and was shown to be far greater than can be achieved by conventional Al grain refiners. Grain refinement by the addition of Sc is accompanied by a change in growth morphology from dendritic, in the large unrefined grains, to fine spherical grains with a divorced eutectic appearing on the grain boundaries in the refined castings. Similar levels of refinement were observed in Al-Sc-Zr and Al-Cu-Sc alloys. In the latter, a change in the segregation behavior of Cu was observed, from a strongly interdendritic segregation pattern to a more homogeneous distribution. The supersaturated Al-Sc solid solution can decompose via a discontinuous precipitation reaction to form coherent rod-like precipitates of the L1 2 Al 3 Sc phase

  1. Synthesis of dilute magnetic semiconductors by ion implantation

    International Nuclear Information System (INIS)

    Braunstein, G.H.; Dresselhaus, G.; Withrow, S.P.

    1986-01-01

    We have synthesized layers of CdMnTe by implantation of Mn into CdTe. Samples of CdTe have been implanted with Mn ions of 60 keV energy to fluences in the range 1 x 10 13 cm -2 to 2 x 10 16 cm -2 resulting in local concentrations of up to 10% at the maximum of the Mn distribution. Rutherford backscattering-channeling analysis has been used to study the radiation damage after implantation and after subsequent rapid thermal annealing (RTA). These experiments reveal that RTA for 15 sec at a temperature T greater than or equal to 700 0 C results in the complete recovery of the lattice order, without affecting the stoichiometry of CdTe. Photoluminescence (PL) measurements of a sample showing complete annealing reveal an increase in the band gap corresponding to the synthesis of very dilute (x approx. = 0.004) Cd/sub 1-x/Mn/sub x/Te. A shift of the excitonic PL peak to lower energies is observed when a magnetic field H less than or equal to 1T is applied. These measurements provide clear evidence for the synthesis of a DMS by ion implantation of Mn into CdTe

  2. Ion separation from dilute electrolyte solutions by nanofiltration

    International Nuclear Information System (INIS)

    Garcia, Corazon M.

    2000-03-01

    Nanofiltration (NF) is a pressure-driven process which is considered potential for the separation of ionic species selectively from solutions containing mixture of electrolyte solutes. The lower operating pressure requirement of NF than reverse osmosis (RO) makes the earlier potentially economical. In the separation of ions, many authors believed that there are membranes with characteristic fixed surface charge and that the mechanism of separation of ions is by the differences in valences of the ions. In this study, experiments involving dilute single-solute and multiple-solute electrolyte solutions were performed using three different NF membranes. Permeate fluxes and ion rejections of the different species of ions in samples of permeate solutions were measured at varied conditions. The mechanism of separation in NF was determined based on the analysis of the trends and behavior of ion rejection relative to the solution temperature, pressure, type of solute, feed concentration and feed solution pH. The results of the experiments show that there is no evidence of the presence of fixed surface charge on the NF membranes. Ion separation was made possible by the combination of sieve effect and ion-hydration effect. Ions having higher hydration numbers showed higher ion rejection than those having lower hydration numbers. A method to determine the effective membrane pore size of NF membranes using hydrodynamic model was proposed. The proposed method is based on the assumptions that the membrane is neutral and that the separation is based on sieving effect. (Author)

  3. Dilute alkali pretreatment of softwood pine: A biorefinery approach.

    Science.gov (United States)

    Safari, Ali; Karimi, Keikhosro; Shafiei, Marzieh

    2017-06-01

    Dilute alkali pretreatment was performed on softwood pine to maximize ethanol and biogas production via a biorefinery approach. Alkali pretreatments were performed with 0-2% w/v NaOH at 100-180°C for 1-5h. The liquid fraction of the pretreated substrates was subjected to anaerobic digestion. The solid fraction of the pretreatment was used for separate enzymatic hydrolysis and fermentation. High ethanol yields of 76.9‒78.0% were achieved by pretreatment with 2% (w/v) NaOH at 180°C. The highest biogas yield of 244mL/g volatile solid (at 25°C, 1bar) was achieved by the pretreatment with 1% (w/v) NaOH at 180°C. The highest gasoline equivalent (sum of ethanol and methane) of 197L per ton of pinewood and the lowest ethanol manufacturing cost of 0.75€/L was obtained after pretreatment with 1% NaOH at 180°C for 5h. The manufacturing cost of ethanol from untreated wood was 4.12€/L. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Isotopic dilution requirements for 233U criticality safety in processing and disposal facilities

    International Nuclear Information System (INIS)

    Elam, K.R.; Forsberg, C.W.; Hopper, C.M.; Wright, R.Q.

    1997-11-01

    The disposal of excess 233 U as waste is being considered. Because 233 U is a fissile material, one of the key requirements for processing 233 U to a final waste form and disposing of it is to avoid nuclear criticality. For many processing and disposal options, isotopic dilution is the most feasible and preferred option to avoid nuclear criticality. Isotopic dilution is dilution of fissile 233 U with nonfissile 238 U. The use of isotopic dilution removes any need to control nuclear criticality in process or disposal facilities through geometry or chemical composition. Isotopic dilution allows the use of existing waste management facilities, that are not designed for significant quantities of fissile materials, to be used for processing and disposing of 233 U. The amount of isotopic dilution required to reduce criticality concerns to reasonable levels was determined in this study to be ∼ 0.66 wt% 233 U. The numerical calculations used to define this limit consisted of a homogeneous system of silicon dioxide (SiO 2 ), water (H 2 O), 233 U, and depleted uranium (DU) in which the ratio of each component was varied to determine the conditions of maximum nuclear reactivity. About 188 parts of DU (0.2 wt% 235 U) are required to dilute 1 part of 233 U to this limit in a water-moderated system with no SiO 2 present. Thus, for the US inventory of 233 U, several hundred metric tons of DU would be required for isotopic dilution

  5. Response to Comment on "Dilution limits dissolved organic carbon utilization in the deep ocean"

    KAUST Repository

    Arrieta, Jesus

    2015-12-18

    Our recent finding that dilution limits dissolved organic carbon (DOC) utilization in the deep ocean has been criticized based on the common misconception that lability equates to rapid and complete utilization. Even when considering the redefinition of recalcitrant DOC recently proposed by Jiao et al., the dilution hypothesis best explains our experimental observations.

  6. The transition between undiluted and oligomer-diluted states of nearly monodisperse polystyrenes in extensional flow

    DEFF Research Database (Denmark)

    Huang, Qian; Rasmussen, Henrik K.

    2017-01-01

    , proposed by Rasmussen and Huang (Rheol Acta 53(3):199–208 (2014a)), predicts the extensional viscosity well for the dilutions with lower concentrations. However, for the 70 and 90% 545 kg/mole samples which represent the transition between the diluted and undiluted states, the model predictions are less...

  7. Chaotic properties of dilute two- and three dimensional random Lorentz gases: Equilibrium systems

    NARCIS (Netherlands)

    van Beijeren, H.; Latz, A.; Dorfman, J.R.

    We compute the Lyapunov spectrum and the Kolmogorov-Sinai entropy for a moving particle placed in a dilute, random array of hard-disk or hard-sphere scatterers, i.e., the dilute Lorentz gas model. This is carried out in two ways. First we use simple kinetic theory arguments to compute the Lyapunov

  8. Risk Assessment of New Chemical Substances. Dilution of Effluents in The Netherlands

    NARCIS (Netherlands)

    de Greef J; de Nijs ACM

    1990-01-01

    A detailed study has been undertaken on the dilution of effluent from waste water treatment plants in The Netherlands. Using a 2-dimensional dispersion model and data from the Central Bureau of Statistics, a general overview of the dilution of effluent in receiving surface waters has been compiled

  9. Comparative determination of sucrose content in sugar beet by polarimetric and isotope dilution methods

    Energy Technology Data Exchange (ETDEWEB)

    Malec, K; Szuchnik, A [Institute of Nuclear Research, Warsaw (Poland); Rydel, S; Walerianaczyk, E [Instytut Przemyslu Cukrowniczego, Warsaw (Poland)

    1976-01-01

    The comparative determination of sucrose content in sugar beets has been investigated by following methods: polarimetric, direct isotope dilution and double carrier-isotope dilution analysis. Basing upon the obtained results it has been ascertained, that in the case of worse quality beets the polarimetric determinations differ greatly from isotopic data.

  10. Effect of Welding Parameters on Dilution and Weld Bead Geometry in Cladding

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The effect of pulsed gas metal arc welding (GMAW) variables on the dilution and weld bead geometry in cladding X65 pipeline steel with 316L stainless steel was studied. Using a full factorial method, a series of experiments were carried out to know the effect of wire feed rate, welding speed, distance between gas nozzle and plate, and the vertical angle of welding on dilution and weld bead geometry. The findings indicate that the dilution of weld metal and its dimension i.e. width, height and depth increase with the feed rate, but the contact angle of the bead decreases first and then increases. Meantime, welding speed has an opposite effect except for dilution. There is an interaction effect between welding parameters at the contact angle. The results also show forehand welding or decreasing electrode extension decrease the angle of contact. Finally,a mathematical model is contrived to highlight the relationship between welding variables with dilution and weld bead geometry.

  11. Study on nitrogen diluted propane-air premixed flames at elevated pressures and temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Tang Chenglong; Zheng Jianjun [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Huang Zuohua, E-mail: zhhuang@mail.xjtu.edu.c [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Wang Jinhua [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China)

    2010-02-15

    Using a high pressure constant volume combustion vessel, the propagation and morphology of spark-ignited outwardly expanding nitrogen diluted propane-air flames were imaged and recorded by schlieren photography and high-speed digital camera. The unstretched laminar burning velocities and Markstein lengths were subsequently determined over wide range of initial temperatures, initial pressures and nitrogen dilution ratios. Two recently developed mechanisms were used to predict the reference laminar burning velocity. The results show that the measured unstretched laminar burning velocities agree well with those in the literature and the computationally predicted results. The flame images show that the diffusional-thermal instability is promoted as the mixture becomes richer, and the hydrodynamic instability is increased with the increase of the initial pressure and it is decreased with the increase of dilution ratio. The normalized laminar burning velocities show a linear correlation with respect to the dilution ratio, indicating that the effect of nitrogen dilution is more obvious at higher pressures.

  12. Oxalate content of different drinkable dilutions of tea infusions after different brewing times.

    Science.gov (United States)

    Lotfi Yagin, Neda; Mahdavi, Reza; Nikniaz, Zeinab

    2012-01-01

    The aims of this study were to determine the effect of different brewing times and diluting on oxalate content of loose-packed black teas consumed in Tabriz, Iran. The oxalate content of black teas after brewing for 5, 10, 15, 30, 60 minutes was measured in triplicate by enzymatic assay. In order to attain the most acceptable dilution of tea infusions, tea samples which were brewed for 15, 30 and 60 minutes were diluted two (120 ml), three (80 ml) and four (60 ml) times respectively. There was a stepwise increase in oxalate concentrations associated with increased brewing times (Pbrewing times, respectively. There were significant differences between the mean oxalate content of different dilutions after brewing for 15, 30 and 60 minutes (Pbrewing times and different dilution was below the recommended levels. Therefore, it seems that consumption of black tea several times per day would not pose significant health risk in kidney stone patients and susceptible individuals.

  13. Polymorphisms within the canine MLPH gene are associated with dilute coat color in dogs

    Directory of Open Access Journals (Sweden)

    Günzel-Apel Anne-Rose

    2005-06-01

    Full Text Available Abstract Background Pinschers and other dogs with coat color dilution show a characteristic pigmentation phenotype. The fur colors are a lighter shade, e.g. silvery grey (blue instead of black and a sandy color (Isabella fawn instead of red or brown. In some dogs the coat color dilution is sometimes accompanied by hair loss and recurrent skin inflammation, the so called color dilution alopecia (CDA or black hair follicular dysplasia (BHFD. In humans and mice a comparable pigmentation phenotype without any documented hair loss is caused by mutations within the melanophilin gene (MLPH. Results We sequenced the canine MLPH gene and performed a mutation analysis of the MLPH exons in 6 Doberman Pinschers and 5 German Pinschers. A total of 48 sequence variations was identified within and between the breeds. Three families of dogs showed co-segregation for at least one polymorphism in an MLPH exon and the dilute phenotype. No single polymorphism was identified in the coding sequences or at splice sites that is likely to be causative for the dilute phenotype of all dogs examined. In 18 German Pinschers a mutation in exon 7 (R199H was consistently associated with the dilute phenotype. However, as this mutation was present in homozygous state in four dogs of other breeds with wildtype pigmentation, it seems unlikely that this mutation is truly causative for coat color dilution. In Doberman Pinschers as well as in Large Munsterlanders with BHFD, a set of single nucleotide polymorphisms (SNPs around exon 2 was identified that show a highly significant association to the dilute phenotype. Conclusion This study provides evidence that coat color dilution is caused by one or more mutations within or near the MLPH gene in several dog breeds. The data on polymorphisms that are strongly associated with the dilute phenotype will allow the genetic testing of Pinschers to facilitate the breeding of dogs with defined coat colors and to select against Large

  14. Just add water: Accuracy of analysis of diluted human milk samples using mid-infrared spectroscopy.

    Science.gov (United States)

    Smith, R W; Adamkin, D H; Farris, A; Radmacher, P G

    2017-01-01

    To determine the maximum dilution of human milk (HM) that yields reliable results for protein, fat and lactose when analyzed by mid-infrared spectroscopy. De-identified samples of frozen HM were obtained. Milk was thawed and warmed (40°C) prior to analysis. Undiluted (native) HM was analyzed by mid-infrared spectroscopy for macronutrient composition: total protein (P), fat (F), carbohydrate (C); Energy (E) was calculated from the macronutrient results. Subsequent analyses were done with 1 : 2, 1 : 3, 1 : 5 and 1 : 10 dilutions of each sample with distilled water. Additional samples were sent to a certified lab for external validation. Quantitatively, F and P showed statistically significant but clinically non-critical differences in 1 : 2 and 1 : 3 dilutions. Differences at higher dilutions were statistically significant and deviated from native values enough to render those dilutions unreliable. External validation studies also showed statistically significant but clinically unimportant differences at 1 : 2 and 1 : 3 dilutions. The Calais Human Milk Analyzer can be used with HM samples diluted 1 : 2 and 1 : 3 and return results within 5% of values from undiluted HM. At a 1 : 5 or 1 : 10 dilution, however, results vary as much as 10%, especially with P and F. At the 1 : 2 and 1 : 3 dilutions these differences appear to be insignificant in the context of nutritional management. However, the accuracy and reliability of the 1 : 5 and 1 : 10 dilutions are questionable.

  15. Conformation of Single Pentablock Ionomer Chains in Dilute Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, Dipak [Clemson Univ., SC (United States); Perahia, Dvora [Clemson Univ., SC (United States); Grest, Gary S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    The conformation of single chain pentablock ionomers (A-B-C-B-A) containing randomly sulfonated polystyrene in the center block, tethered to poly-ethylene-r-propylene end-capped by poly-t-butyl styrene is studied in dilute solutions by molecular dynamics simulations. Multi-block copolymers offer a means to tailor several properties into one molecule, taking advantage of their rich phase diagram together with unique properties of specific blocks. For this pentablock the ionic block facilitates transport while the A and B components are incorporated for mechanical stability. The present study investigates the confirmation of a single chain of pentablock ionomer of molecular weight Mw ~ 50,000 g/mol and sulfonated polystyrene of the same molecular weight as that of the center block for six sulfonation fractions f from f=0.0-0.55. For the sulfonated systems Na+ counterions are included. Results for the equilibrium conformation of the chains and the three blocks in water and 1:1 mixture of cyclohexane and n-heptane are compared to simulations in implicit poor solvents with dielectric constants ε =1.0 and 77.73. In water, the pentablock is collapsed with sulfonated groups on the outer surface. As the sulfonation fraction f increases, the ionic, center block is increasingly segregated from the hydrophobic regions. In the 1:1 mixture of cyclohexane and heptane both the flexible and end blocks are swollen while the center ionic block is collasped for f>0, while for f=0 all blocks are swollen. In both implicit poor solvents the pentablock is collapsed into a nearly spherical shape for all f. The sodium counterions are dispersed widely throughout the simulation cell for both water and ε =77.73 whereas for ε =1.0 the counterions are largely condensed on the collapsed pentablock.

  16. Precipitation hardening in dilute Al–Zr alloys

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Lamarão Souza

    2018-01-01

    Full Text Available The aim of this study was to investigate the effect of solute content (hipoperitectic Al–0.22 wt.%Zr and hiperperitectic Al–0.32 wt.%Zr on the precipitation hardening and microstructural evolution of dilute Al–Zr alloys isothermally aged. The materials were conventionally cast in a muffle furnace, solidified in a water-cooled Cu mold and subsequently heat-treated at the temperature of 650 K (377 °C for 4, 12, 24, 100 and 400 h. Mechanical characterization was performed at room temperature, using a microhardness tester and microstructural characterization was carried out on a Transmission Electron Microscope – TEM. The observed microhardness values increased during isothermal aging, due to the precipitation of nanometer-scale Al3Zr L12 particles. Peak strength was achieved within 100 h of aging. After aging for 400 h, microhardness values presented a slight decrease for both alloys, thus indicating overaging due to the coalescence of precipitates. Microhardness values increased with solute content, due to the precipitation of a higher number density of finer precipitates. After 400 h of heat-treating, coalescence was higher for the alloy with lower solute content and, also, the presence of antiphase boundaries – APBs, planar faults associated with the L12 to D023 structural transition, were observed. Comparing theoretical calculations of the increment in strength due to precipitation strengthening with experimental results, it was observed that their values are in reasonable agreement. The Orowan dislocation looping mechanism takes place during precipitation hardening for both alloys in the peak hardness condition.

  17. Interactions between Zygosaccharomyces mellis and Wallemia sebi in diluted molasses.

    Science.gov (United States)

    Vindeløv, J; Arneborg, N

    2001-01-22

    The yeast Zygosaccharomyces mellis and the mould Wallemia sebi were isolated from the same sample of crystalline sugar. Interactions between these fungi were investigated using a diluted molasses medium (water activity 0.89, pH 6.0) as a model system for the syrup film covering the surface of moist crystalline sugar. Single and mixed cultures of Z. mellis and W. sebi were incubated at 25 degrees C for 400 h. Our results show that the growth of Z. mellis in single culture was limited by available glucose and fructose, and that W sebi was able to invert sucrose to glucose and fructose in both single and mixed culture. Furthermore, the presence of W. sebi in the mixed culture increased the maximum specific growth rate of Z. mellis from 0.074 to 0.19 h(-1) and the growth yield of Z. mellis from 7.3 x 10(6) to 5.4 x 10(7) cfu/ml. These results indicate that the ability of W. sebi to invert sucrose may stimulate the growth of Z. mellis. Finally, the presence of Z. mellis inhibited the ability of W. sebi to invert sucrose: W. sebi was able to invert 1.0 g sucrose/l per h in single culture but only 0.6 g sucrose/l per h in mixed culture. As predicted by Raoults law, this corresponded to a reduction in the water activity of the growth medium from 0.890 to 0.850 in single culture, and to 0.865 in mixed culture.

  18. Thermodynamics of dilute aqueous solutions of imidazolium based ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Tejwant [Salt and Marine Chemicals Division, Central Salt and Marine Chemicals Research Institute, Council of Scientific and Industrial Research (CSIR), G.B. Marg, Bhavnagar 364002 (India); Kumar, Arvind, E-mail: arvind@csmcri.or [Salt and Marine Chemicals Division, Central Salt and Marine Chemicals Research Institute, Council of Scientific and Industrial Research (CSIR), G.B. Marg, Bhavnagar 364002 (India)

    2011-06-15

    Research highlights: The thermodynamic behaviour of aqueous imidazolium ILs has been investigated. Volumetric and ultrasonic results indicated the hydrophobic hydration of ILs. Viscometric studies revealed studied ionic liquids as water-structure makers. Hydration number increased with increase in alkyl chain length of the cation. - Abstract: Experimental measurements of density {rho}, speed of sound u, and viscosity {eta} of aqueous solutions of various 1-alkyl-3-methylimidazolium based ionic liquid (IL) solutions have been performed in dilute concentration regime at 298.15 K to get insight into hydration behaviour of ILs. The investigated ILs are based on 1-alkyl-3-methylimidazolium cation, [C{sub n}mim] having [BF{sub 4}]{sup -}, [Cl]{sup -}, [C{sub 1}OSO{sub 3}]{sup -}, and [C{sub 8}OSO{sub 3}]{sup -} as anions where n = 4 or 8. Several thermodynamic parameters like apparent molar volume {phi}{sub V}, isentropic compressibility {beta}{sub s}, and viscosity B-coefficients have been derived from experimental data. Limiting value of apparent molar volume has been discussed in terms of intrinsic molar volume (V{sub int}) molar electrostriction volume (V{sub elec}), molar disordered (V{sub dis}), and cage volume (V{sub cage}). Viscosity B-coefficients have been used to quantify the kosmotropic or chaotropic nature of ILs. Hydration number of ILs obtained using elctrostriction volume, isentropic compressibility, viscosity, and differential scanning calorimetry have been found to be comparative within the experimental error. The hydrophobic hydration has found to play an important role in hydration of ILs as compared to hydration due to hydrogen bonding and electrostriction. Limiting molar properties, hydration numbers, and B-coefficients have been discussed in terms of alkyl chain length of cation or nature of anion.

  19. Dilute Al and V NMR in α-Ti

    International Nuclear Information System (INIS)

    Chou, L.H.; Rowland, T.J.

    1992-01-01

    We report a nuclear-magnetic-resonance investigation of four titanium alloys: Ti--1 at. % V, Ti--2 at. % V, Ti--1 at. % Al, and Ti--2 at. % Al. Interpretation of the experimental 51 V and 27 Al absorption curves was accomplished largely by comparison with computer-simulated curves. Since the latter include the effects of nuclear-quadrupole and anisotropic Knight-shift interactions, dipolar broadening, and inhomogeneous Knight shift for the V and Al solute nuclei, the comparison yields experimental values for the electric-field gradient, axially symmetric anistropic Knight shift, and isotropic Knight shift, from which we attempt to deduce the local charge distribution at the V or Al atoms in the hcp α-Ti matrix. We find that the localized states on an Al impurity exhibit very little of the character of the host Ti atomic structure. There is no orbital contribution to the Knight shift and the s conduction-electron density at Al sites is small. On the other hand, when vanadium is present as a dilute solute in the Ti lattice, only minor changes in its Knight shift are found. There is a large orbital-shift contribution, and the V nuclear absorption exhibits much the same character as in pure metallic V; there is, however, clear evidence of the V charge distribution assuming the hexagonal symmetry of the Ti lattice. The measured temperature dependences of the anisotropic Knight shift and electric-field-gradient values at V solute sites in Ti are also discussed. On partitioning the field gradient we find that the contribution from local non-s electrons is about two to five times larger in magnitude than the Ti-lattice ion value, a strong indication that the electronic structure near V (but not Al) resembles that of the matrix Ti

  20. Thermodynamics of dilute aqueous solutions of imidazolium based ionic liquids

    International Nuclear Information System (INIS)

    Singh, Tejwant; Kumar, Arvind

    2011-01-01

    Research highlights: → The thermodynamic behaviour of aqueous imidazolium ILs has been investigated. → Volumetric and ultrasonic results indicated the hydrophobic hydration of ILs. → Viscometric studies revealed studied ionic liquids as water-structure makers. → Hydration number increased with increase in alkyl chain length of the cation. - Abstract: Experimental measurements of density ρ, speed of sound u, and viscosity η of aqueous solutions of various 1-alkyl-3-methylimidazolium based ionic liquid (IL) solutions have been performed in dilute concentration regime at 298.15 K to get insight into hydration behaviour of ILs. The investigated ILs are based on 1-alkyl-3-methylimidazolium cation, [C n mim] having [BF 4 ] - , [Cl] - , [C 1 OSO 3 ] - , and [C 8 OSO 3 ] - as anions where n = 4 or 8. Several thermodynamic parameters like apparent molar volume φ V , isentropic compressibility β s , and viscosity B-coefficients have been derived from experimental data. Limiting value of apparent molar volume has been discussed in terms of intrinsic molar volume (V int ) molar electrostriction volume (V elec ), molar disordered (V dis ), and cage volume (V cage ). Viscosity B-coefficients have been used to quantify the kosmotropic or chaotropic nature of ILs. Hydration number of ILs obtained using elctrostriction volume, isentropic compressibility, viscosity, and differential scanning calorimetry have been found to be comparative within the experimental error. The hydrophobic hydration has found to play an important role in hydration of ILs as compared to hydration due to hydrogen bonding and electrostriction. Limiting molar properties, hydration numbers, and B-coefficients have been discussed in terms of alkyl chain length of cation or nature of anion.