WorldWideScience

Sample records for digital coherent detection

  1. GHz wireless On-off-Keying link employing all photonic RF carrier generation and digital coherent detection

    DEFF Research Database (Denmark)

    Sambaraju, Rakesh; Zibar, Darko; Caballero Jambrina, Antonio

    2010-01-01

    Gb/s wireless signals at 82, 88 and 100 GHz carrier frequencies are successfully generated by heterodyne mixing of two optical carriers. A photonic detection technique with optical coherent receiver and digital signal processing is implemented for signal demodulation....

  2. Digital coherent detection research on Brillouin optical time domain reflectometry with simplex pulse codes

    International Nuclear Information System (INIS)

    Hao Yun-Qi; Ye Qing; Pan Zheng-Qing; Cai Hai-Wen; Qu Rong-Hui

    2014-01-01

    The digital coherent detection technique has been investigated without any frequency-scanning device in the Brillouin optical time domain reflectometry (BOTDR), where the simplex pulse codes are applied in the sensing system. The time domain signal of every code sequence is collected by the data acquisition card (DAQ). A shift-averaging technique is applied in the frequency domain for the reason that the local oscillator (LO) in the coherent detection is fix-frequency deviated from the primary source. With the 31-bit simplex code, the signal-to-noise ratio (SNR) has 3.5-dB enhancement with the same single pulse traces, accordant with the theoretical analysis. The frequency fluctuation for simplex codes is 14.01 MHz less than that for a single pulse as to 4-m spatial resolution. The results are believed to be beneficial for the BOTDR performance improvement. (general)

  3. Anatomy of a digital coherent receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zibar, Darko; Tafur Monroy, Idelfonso

    2014-01-01

    , orthonormaliation, chromatic dispersion compensation/nonlinear compensation, resampling a nd timing recovery, polarization demultiplexing and equalization, frequency and phase recovery, digital demodulation. We also describe novel subsystems of a digital coherent receiver: modulation format recognition......Digital coherent receivers have gained significant attention in the last decade. The reason for this is that coherent detection, along with digital signal processing (DSP) allows for substantial increase of the channel capacity by employing advanced detection techniques. In this paper, we first...

  4. Detection of coherent beam-beam modes with digitized beam position monitor signals

    CERN Document Server

    Stancari, G.; White, S.M.

    2014-01-01

    A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Fermilab Tevatron collider is described. It is based on the signal from a single beam-position monitor located in a region of the ring with large amplitude functions. The signal is digitized over a large number of turns and Fourier-analyzed offline with a dedicated algorithm. To enhance the signal, band-limited noise is applied to the beam for about 1 s. This excitation does not adversely affect the circulating beams even at high luminosities. The device has a response time of a few seconds, a frequency resolution of $1.6\\times 10^{-5}$ in fractional tune, and it is sensitive to oscillation amplitudes of 60 nm. It complements Schottky detectors as a diagnostic tool for tunes, tune spreads, and beam-beam effects. Measurements of coherent mode spectra are presented and compared with models of beam-beam oscillations.

  5. Motion and Form Coherence Detection in Autistic Spectrum Disorder: Relationship to Motor Control and 2:4 Digit Ratio

    Science.gov (United States)

    Milne, Elizabeth; White, Sarah; Campbell, Ruth; Swettenham, John; Hansen, Peter; Ramus, Franck

    2006-01-01

    Children with autistic spectrum disorder and controls performed tasks of coherent motion and form detection, and motor control. Additionally, the ratio of the 2nd and 4th digits of these children, which is thought to be an indicator of foetal testosterone, was measured. Children in the experimental group were impaired at tasks of motor control,…

  6. Radio over fiber link with adaptive order n‐QAM optical phase modulated OFDM and digital coherent detection

    DEFF Research Database (Denmark)

    Arlunno, Valeria; Borkowski, Robert; Guerrero Gonzalez, Neil

    2011-01-01

    Successful digital coherent demodulation of asynchronous optical phase‐modulated adaptive order QAM (4, 16, and 64) orthogonal frequency division multiplexing signals is achieved by a single reconfigurable digital receiver after 78 km of optical deployed fiber transmission....

  7. Vertical‐cavity surface‐emitting laser based digital coherent detection for multigigabit long reach passive optical links

    DEFF Research Database (Denmark)

    Rodes Lopez, Roberto; Jensen, Jesper Bevensee; Zibar, Darko

    2011-01-01

    We report on experimental demonstration of digital coherent detection based on a directly modulated vertical‐cavity surface‐emitting laser with bit rate up to 10 Gbps. This system allows a cooler‐less, free running, and unamplified transmission without optical dispersion compensation up to 105 km...... at 5 Gbps long reach passive optical links. © 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett 53:2462–2464, 2011; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26331...

  8. Generation and coherent detection of QPSK signal using a novel method of digital signal processing

    Science.gov (United States)

    Zhao, Yuan; Hu, Bingliang; He, Zhen-An; Xie, Wenjia; Gao, Xiaohui

    2018-02-01

    We demonstrate an optical quadrature phase-shift keying (QPSK) signal transmitter and an optical receiver for demodulating optical QPSK signal with homodyne detection and digital signal processing (DSP). DSP on the homodyne detection scheme is employed without locking the phase of the local oscillator (LO). In this paper, we present an extracting one-dimensional array of down-sampling method for reducing unwanted samples of constellation diagram measurement. Such a novel scheme embodies the following major advantages over the other conventional optical QPSK signal detection methods. First, this homodyne detection scheme does not need strict requirement on LO in comparison with linear optical sampling, such as having a flat spectral density and phase over the spectral support of the source under test. Second, the LabVIEW software is directly used for recovering the QPSK signal constellation without employing complex DSP circuit. Third, this scheme is applicable to multilevel modulation formats such as M-ary PSK and quadrature amplitude modulation (QAM) or higher speed signals by making minor changes.

  9. Chromatic Dispersion Estimation in Digital Coherent Receivers

    DEFF Research Database (Denmark)

    Soriano, Ruben Andres; Hauske, Fabian N.; Guerrero Gonzalez, Neil

    2011-01-01

    Polarization-diverse coherent demodulation allows to compensate large values of accumulated linear distortion by digital signal processing. In particular, in uncompensated links without optical dispersion compensation, the parameter of the residual chromatic dispersion (CD) is vital to set...

  10. All-VCSEL based digital coherent detection link for multi Gbit/s WDM passive optical networks

    DEFF Research Database (Denmark)

    Rodes Lopez, Roberto; Jensen, Jesper Bevensee; Zibar, Darko

    2010-01-01

    with record receiver sensitivity of -36 dBm after transmission over 40 km standard single mode fiber. Digital signal processing compensates for frequency offset between the transmitter and the local oscillator VCSELs, and for chromatic dispersion. This system allows for uncooled VCSEL operation and fully...

  11. On Radar Resolution in Coherent Change Detection.

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Douglas L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    It is commonly observed that resolution plays a role in coherent change detection. Although this is the case, the relationship of the resolution in coherent change detection is not yet defined . In this document, we present an analytical method of evaluating this relationship using detection theory. Specifically we examine the effect of resolution on receiver operating characteristic curves for coherent change detection.

  12. Turbo Equalization for Digital Coherent Receivers

    DEFF Research Database (Denmark)

    Arlunno, Valeria; Caballero Jambrina, Antonio; Borkowski, Robert

    2014-01-01

    . In this paper, it is demonstrated that Turbo Equalization routines can be used to mitigate performance degradations stemming from optical fiber propagation effects both in optical fiber dispersion managed and unmanaged coherent detection links. The effectiveness of this solution is analyzed both numerically...

  13. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  14. Digital Signal Processing for Optical Coherent Communication Systems

    DEFF Research Database (Denmark)

    Zhang, Xu

    spectrum narrowing tolerance 112-Gb/s DP-QPSK optical coherent systems using digital adaptive equalizer. The demonstrated results show that off-line DSP algorithms are able to reduce the bit error rate (BER) penalty induced by signal spectrum narrowing. Third, we also investigate bi...... wavelength division multiplex (U-DWDM) optical coherent systems based on 10-Gbaud QPSK. We report U-DWDM 1.2-Tb/s QPSK coherent system achieving spectral efficiency of 4.0-bit/s/Hz. In the experimental demonstration, digital decision feed back equalizer (DFE) algorithms and a finite impulse response (FIR......In this thesis, digital signal processing (DSP) algorithms are studied to compensate for physical layer impairments in optical fiber coherent communication systems. The physical layer impairments investigated in this thesis include optical fiber chromatic dispersion, polarization demultiplexing...

  15. COHERENT DETECTION FOR SPECTRAL AMPLITUDE-CODED OPTICAL LABEL SWITCHING SYSTEMS

    DEFF Research Database (Denmark)

    Osadchiy, Alexey Vladimirovich; Tafur Monroy, Idelfonso

    2010-01-01

    Coherent detection for spectrally encoded optical labels is proposed and experimentally demonstrated for three label tones spectrally spaced at 1 GHz. The proposed method utilizes a frequency swept local oscillator in a coherent receiver supported by digital signal processing for improved...... flexibility and upgradeability while reducing label detection subsystem complexity as compared with the conventional optical autocorrelation based approaches....

  16. Coherent Detection of Wavelength Division Multiplexed Phase-Modulated Radio-over-Fibre Signals

    DEFF Research Database (Denmark)

    Zibar, Darko; Yu, Xianbin; Peucheret, Christophe

    2008-01-01

    A WDM phase-modulated Radio-over-Fibre link using digital coherent detection is experimentally demonstrated. 3 times 50 Mb/s WDM transmission of a BPSK modulated 5 GHz RF carrier is achieved over 25 km.......A WDM phase-modulated Radio-over-Fibre link using digital coherent detection is experimentally demonstrated. 3 times 50 Mb/s WDM transmission of a BPSK modulated 5 GHz RF carrier is achieved over 25 km....

  17. Digital quadrature phase detection

    Science.gov (United States)

    Smith, J.A.; Johnson, J.A.

    1992-05-26

    A system for detecting the phase of a frequency or phase modulated signal that includes digital quadrature sampling of the frequency or phase modulated signal at two times that are one quarter of a cycle of a reference signal apart, determination of the arctangent of the ratio of a first sampling of the frequency or phase modulated signal to the second sampling of the frequency or phase modulated signal, and a determination of quadrant in which the phase determination is increased by 2[pi] when the quadrant changes from the first quadrant to the fourth quadrant and decreased by 2[pi] when the quadrant changes from the fourth quadrant to the first quadrant whereby the absolute phase of the frequency or phase modulated signal can be determined using an arbitrary reference convention. 6 figs.

  18. Performance Evaluation of Digital Coherent Receivers for Phase-Modulated Radio-Over-Fiber Links

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Zibar, Darko; Tafur Monroy, Idelfonso

    2011-01-01

    The performance of optical phase-modulated (PM) radio-over-fiber (RoF) links assisted with coherent detection and digital signal processing (PM-Coh) is analyzed and experimentally demonstrated for next-generation wireless-over-fiber systems. PM-Coh offers high linearity for transparent transport ...

  19. Coherent imaging with incoherent light in digital holographic microscopy

    Science.gov (United States)

    Chmelik, Radim

    2012-01-01

    Digital holographic microscope (DHM) allows for imaging with a quantitative phase contrast. In this way it becomes an important instrument, a completely non-invasive tool for a contrast intravital observation of living cells and a cell drymass density distribution measurement. A serious drawback of current DHMs is highly coherent illumination which makes the lateral resolution worse and impairs the image quality by a coherence noise and a parasitic interference. An uncompromising solution to this problem can be found in the Leith concept of incoherent holography. An off-axis hologram can be formed with arbitrary degree of light coherence in systems equipped with an achromatic interferometer and thus the resolution and the image quality typical for an incoherent-light wide-field microscopy can be achieved. In addition, advanced imaging modes based on limited coherence can be utilized. The typical example is a coherence-gating effect which provides a finite axial resolution and makes DHM image similar to that of a confocal microscope. These possibilities were described theoretically using the formalism of three-dimensional coherent transfer functions and proved experimentally by the coherence-controlled holographic microscope which is DHM based on the Leith achromatic interferometer. Quantitative-phase-contrast imaging is demonstrated with incoherent light by the living cancer cells observation and their motility evaluation. The coherence-gating effect was proved by imaging of model samples through a scattering layer and living cells inside an opalescent medium.

  20. Multiple symbol partially coherent detection of MPSK

    Science.gov (United States)

    Simon, M. K.; Divsalar, D.

    1992-01-01

    It is shown that by using the known (or estimated) value of carrier tracking loop signal to noise ratio (SNR) in the decision metric, it is possible to improve the error probability performance of a partially coherent multiple phase-shift-keying (MPSK) system relative to that corresponding to the commonly used ideal coherent decision rule. Using a maximum-likeihood approach, an optimum decision metric is derived and shown to take the form of a weighted sum of the ideal coherent decision metric (i.e., correlation) and the noncoherent decision metric which is optimum for differential detection of MPSK. The performance of a receiver based on this optimum decision rule is derived and shown to provide continued improvement with increasing length of observation interval (data symbol sequence length). Unfortunately, increasing the observation length does not eliminate the error floor associated with the finite loop SNR. Nevertheless, in the limit of infinite observation length, the average error probability performance approaches the algebraic sum of the error floor and the performance of ideal coherent detection, i.e., at any error probability above the error floor, there is no degradation due to the partial coherence. It is shown that this limiting behavior is virtually achievable with practical size observation lengths. Furthermore, the performance is quite insensitive to mismatch between the estimate of loop SNR (e.g., obtained from measurement) fed to the decision metric and its true value. These results may be of use in low-cost Earth-orbiting or deep-space missions employing coded modulations.

  1. Multi-aperture digital coherent combining for free-space optical communication receivers.

    Science.gov (United States)

    Geisler, David J; Yarnall, Timothy M; Stevens, Mark L; Schieler, Curt M; Robinson, Bryan S; Hamilton, Scott A

    2016-06-13

    Space-to-ground optical communication systems can benefit from reducing the size, weight, and power profiles of space terminals. One way of reducing the required power-aperture product on a space platform is to implement effective, but costly, single-aperture ground terminals with large collection areas. In contrast, we present a ground terminal receiver architecture in which many small less-expensive apertures are efficiently combined to create a large effective aperture while maintaining excellent receiver sensitivity. This is accomplished via coherent detection behind each aperture followed by digitization. The digitized signals are then combined in a digital signal processing chain. Experimental results demonstrate lossless coherent combining of four lasercom signals, at power levels below 0.1 photons/bit/aperture.

  2. High-Capacity 60 GHz and 75–110 GHz Band Links Employing All-Optical OFDM Generation and Digital Coherent Detection

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Zibar, Darko; Sambaraju, Rakesh

    2012-01-01

    The performance of wireless signal generation and detection at millimeter-wave frequencies using baseband optical means is analyzed and experimentally demonstrated. Multigigabit wireless signal generation is achieved based on all-optical orthogonal frequency division multiplexing (OFDM) and photo......The performance of wireless signal generation and detection at millimeter-wave frequencies using baseband optical means is analyzed and experimentally demonstrated. Multigigabit wireless signal generation is achieved based on all-optical orthogonal frequency division multiplexing (OFDM...... scalability and bit-rate transparency of our proposed approach, we experimentally demonstrated generation and detection in the 60 GHz and 75–110 GHz band of an all-optical OFDM quadrature phase shift keying, with two and three subcarriers, for a total bit rate over 20 Gb/ s....

  3. Lagrangian based methods for coherent structure detection

    Energy Technology Data Exchange (ETDEWEB)

    Allshouse, Michael R., E-mail: mallshouse@chaos.utexas.edu [Center for Nonlinear Dynamics and Department of Physics, University of Texas at Austin, Austin, Texas 78712 (United States); Peacock, Thomas, E-mail: tomp@mit.edu [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2015-09-15

    There has been a proliferation in the development of Lagrangian analytical methods for detecting coherent structures in fluid flow transport, yielding a variety of qualitatively different approaches. We present a review of four approaches and demonstrate the utility of these methods via their application to the same sample analytic model, the canonical double-gyre flow, highlighting the pros and cons of each approach. Two of the methods, the geometric and probabilistic approaches, are well established and require velocity field data over the time interval of interest to identify particularly important material lines and surfaces, and influential regions, respectively. The other two approaches, implementing tools from cluster and braid theory, seek coherent structures based on limited trajectory data, attempting to partition the flow transport into distinct regions. All four of these approaches share the common trait that they are objective methods, meaning that their results do not depend on the frame of reference used. For each method, we also present a number of example applications ranging from blood flow and chemical reactions to ocean and atmospheric flows.

  4. Analysis of parallel optical sampling rate and ADC requirements in digital coherent receivers

    DEFF Research Database (Denmark)

    Lorences Riesgo, Abel; Galili, Michael; Peucheret, Christophe

    2012-01-01

    We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator.......We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator....

  5. Multiple-Symbol, Partially Coherent Detection of MPSK

    Science.gov (United States)

    Simon, Marvin K.; Divsalar, Dariush

    1994-01-01

    Proposed method of reception of multiple-phase-shift-keyed (MPSK) radio signals involves multiple-symbol, partially coherent detection. Instead of attempting to determine phase of transmitted signal during each symbol period as in coherent detection, receiver acquires signal data during multiple-symbol observation interval, then produces maximum-likelihood-sequence estimate of phases transmitted during interval. Combination of coherent-reception and incoherent-reception decision rules are used.

  6. Polarization sensitive optical coherence tomography detection method

    International Nuclear Information System (INIS)

    Colston, B W; DaSilva, L B; Everett, M J; Featherstone, J D B; Fried, D; Ragadio, J N; Sathyam, U S.

    1999-01-01

    This study demonstrates the potential of polarization sensitive optical coherence tomography (PS-OCT) for non-invasive in vivo detection and characterization of early, incipient caries lesions. PS-OCT generates cross-sectional images of biological tissue while measuring the effect of the tissue on the polarization state of incident light. Clear discrimination between regions of normal and demineralized enamel is first shown in PS-OCT images of bovine enamel blocks containing well-characterized artificial lesions. High-resolution, cross-sectional images of extracted human teeth are then generated that clearly discriminate between the normal and carious regions on both the smooth and occlusal surfaces. Regions of the teeth that appeared to be demineralized in the PS-OCT images were verified using histological thin sections examined under polarized light microscopy. The PS-OCT system discriminates between normal and carious regions by measuring the polarization state of the back-scattered 1310 nm light, which is affected by the state of demineralization of the enamel. Demineralization of enamel increases the scattering coefficient, thus depolarizing the incident light. This study shows that PS-OCT has great potential for the detection, characterization, and monitoring of incipient caries lesions

  7. Synthesis method from low-coherence digital holograms for improvement of image quality in holographic display.

    Science.gov (United States)

    Mori, Yutaka; Nomura, Takanori

    2013-06-01

    In holographic displays, it is undesirable to observe the speckle noises with the reconstructed images. A method for improvement of reconstructed image quality by synthesizing low-coherence digital holograms is proposed. It is possible to obtain speckleless reconstruction of holograms due to low-coherence digital holography. An image sensor records low-coherence digital holograms, and the holograms are synthesized by computational calculation. Two approaches, the threshold-processing and the picking-a-peak methods, are proposed in order to reduce random noise of low-coherence digital holograms. The reconstructed image quality by the proposed methods is compared with the case of high-coherence digital holography. Quantitative evaluation is given to confirm the proposed methods. In addition, the visual evaluation by 15 people is also shown.

  8. Intelligent detection of microcalcification from digitized mammograms

    Indian Academy of Sciences (India)

    Permanent link: https://www.ias.ac.in/article/fulltext/sadh/036/01/0125-0139. Keywords. Breast cancer; digital mammogram; artificial neural networks; microcalcification detection. Abstract. This paper reports the design and implementation of an intelligent system for detection of microcalcification from digital mammograms.

  9. Detecting phase synchronization between coupled non-phase-coherent oscillators

    International Nuclear Information System (INIS)

    Follmann, Rosangela; Macau, Elbert E.N.; Rosa, Epaminondas

    2009-01-01

    We compare two methods for detecting phase synchronization in coupled non-phase-coherent oscillators. One method is based on the locking of self-sustained oscillators with an irregular signal. The other uses trajectory recurrences in phase space. We identify the pros and cons of both methods and propose guidelines to detect phase synchronization in data series.

  10. Fingerprint fake detection by optical coherence tomography

    Science.gov (United States)

    Meissner, Sven; Breithaupt, Ralph; Koch, Edmund

    2013-03-01

    The most established technique for the identification at biometric access control systems is the human fingerprint. While every human fingerprint is unique, fingerprints can be faked very easily by using thin layer fakes. Because commercial fingerprint scanners use only a two-dimensional image acquisition of the finger surface, they can only hardly differentiate between real fingerprints and fingerprint fakes applied on thin layer materials. A Swept Source OCT system with an A-line rate of 20 kHz and a lateral and axial resolution of approximately 13 μm, a centre wavelength of 1320 nm and a band width of 120 nm (FWHM) was used to acquire fingerprints and finger tips with overlying fakes. Three-dimensional volume stacks with dimensions of 4.5 mm x 4 mm x 2 mm were acquired. The layering arrangement of the imaged finger tips and faked finger tips was analyzed and subsequently classified into real and faked fingerprints. Additionally, sweat gland ducts were detected and consulted for the classification. The manual classification between real fingerprints and faked fingerprints results in almost 100 % correctness. The outer as well as the internal fingerprint can be recognized in all real human fingers, whereby this was not possible in the image stacks of the faked fingerprints. Furthermore, in all image stacks of real human fingers the sweat gland ducts were detected. The number of sweat gland ducts differs between the test persons. The typical helix shape of the ducts was observed. In contrast, in images of faked fingerprints we observe abnormal layer arrangements and no sweat gland ducts connecting the papillae of the outer fingerprint and the internal fingerprint. We demonstrated that OCT is a very useful tool to enhance the performance of biometric control systems concerning attacks by thin layer fingerprint fakes.

  11. A generalized coherence framework for detecting and characterizing nonlinear interactions in the nervous system

    NARCIS (Netherlands)

    Yang, Y.; Solis Escalante, T.; van der Helm, F.C.T.; Schouten, A.C.

    2016-01-01

    Objective: This paper introduces a generalized coherence framework for detecting and characterizing nonlinear interactions in the nervous system, namely cross-spectral coherence (CSC). CSC can detect different types of nonlinear interactions including harmonic and intermodulation coupling as present

  12. Coherent and Incoherent Neutral Current Scattering for Supernova Detection

    Directory of Open Access Journals (Sweden)

    P. C. Divari

    2012-01-01

    Full Text Available The total cross sections as well as the neutrino event rates are calculated in the neutral current neutrino scattering off 40Ar and 132Xe isotopes at neutrino energies (Ev<100 MeV. The individual contribution coming from coherent and incoherent channels is taking into account. An enhancement of the neutral current component is achieved via the coherent (0gs+→0gs+ channel which is dominant with respect to incoherent (0gs+→Jf one. The response of the above isotopes as a supernova neutrino detection has been considered, assuming a two parameter Fermi-Dirac distribution for the supernova neutrino energy spectra. The calculated total cross sections are tested on a gaseous spherical TPC detector dedicated for supernova neutrino detection.

  13. Detection and spectral measurements of coherent synchrotron radiation at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, Christopher

    2010-02-15

    The operation of high-gain free-electron laser (FEL) underlies tremendous demands on high quality electron beams with high peak currents. At the Free-Electron-Laser in Hamburg (FLASH), two magnetic bunch compressors are used to compress the electron bunches longitudinally. In the bunch compressor magnets, these short electron bunches generate coherent synchrotron radiation (CSR). This CSR contains information on the longitudinal bunch profile, which is relevant for driving an FEL. In order to investigate coherent synchrotron radiation at the second bunch compressor BC3 at FLASH, a new setup behind the last dipole was installed. For the detection of coherent synchrotron radiation, which is emitted in the infrared regime, pyroelectric detectors were used. These pyroelectric detectors have been calibrated at the free-electron laser FELIX in the wavelength range from 5 {mu}m to 110 {mu}m. For characterisation of the emitted radiation, a transverse scanning device was used to measure the transverse intensity distribution. Various transmission filters were used to obtain additional information about the spectral content. In order to get spectral information with high resolution over a wide wavelength range, a rotating mirror spectrometer using reflective blazed gratings was installed. Using this spectrometer, the first spectral measurements of coherent synchrotron radiation at FLASH in a wavelength range from 10 {mu}m to 160 {mu}m were done. (orig.)

  14. Detection and spectral measurements of coherent synchrotron radiation at FLASH

    International Nuclear Information System (INIS)

    Behrens, Christopher

    2010-02-01

    The operation of high-gain free-electron laser (FEL) underlies tremendous demands on high quality electron beams with high peak currents. At the Free-Electron-Laser in Hamburg (FLASH), two magnetic bunch compressors are used to compress the electron bunches longitudinally. In the bunch compressor magnets, these short electron bunches generate coherent synchrotron radiation (CSR). This CSR contains information on the longitudinal bunch profile, which is relevant for driving an FEL. In order to investigate coherent synchrotron radiation at the second bunch compressor BC3 at FLASH, a new setup behind the last dipole was installed. For the detection of coherent synchrotron radiation, which is emitted in the infrared regime, pyroelectric detectors were used. These pyroelectric detectors have been calibrated at the free-electron laser FELIX in the wavelength range from 5 μm to 110 μm. For characterisation of the emitted radiation, a transverse scanning device was used to measure the transverse intensity distribution. Various transmission filters were used to obtain additional information about the spectral content. In order to get spectral information with high resolution over a wide wavelength range, a rotating mirror spectrometer using reflective blazed gratings was installed. Using this spectrometer, the first spectral measurements of coherent synchrotron radiation at FLASH in a wavelength range from 10 μm to 160 μm were done. (orig.)

  15. Advanced Equalization Techniques for Digital Coherent Optical Receivers

    DEFF Research Database (Denmark)

    Arlunno, Valeria

    approach based on joint encoding and equalization technique, known as Turbo Equalization (TE). This scheme is demonstrated to be powerful in transmission impairments mitigation for high order modulations formats, such as 16 Quadrature Amplitude Modulation (QAM), considered a key technology for high speed...... a lower complexity convolutional code compared to state of the art reports. Furthermore, in order to fulfill the strict constrains of spectral efficiency, this thesis shows the application of digital adaptive equalizer for reconfigurable and Ultra Dense Wavelength Division Multiplexing (U......-over-Fiber (RoF) transmission system for a stand alone case and mixed modulation mixed bit rates transmission scheme. In conclusion, this PhD thesis demonstrates the flexibility, upgrade-ability and robustness offered by rising advanced digital signal processing techniques, for future high-speed, high...

  16. A digital signal processing system for coherent laser radar

    Science.gov (United States)

    Hampton, Diana M.; Jones, William D.; Rothermel, Jeffry

    1991-01-01

    A data processing system for use with continuous-wave lidar is described in terms of its configuration and performance during the second survey mission of NASA'a Global Backscatter Experiment. The system is designed to estimate a complete lidar spectrum in real time, record the data from two lidars, and monitor variables related to the lidar operating environment. The PC-based system includes a transient capture board, a digital-signal processing (DSP) board, and a low-speed data-acquisition board. Both unprocessed and processed lidar spectrum data are monitored in real time, and the results are compared to those of a previous non-DSP-based system. Because the DSP-based system is digital it is slower than the surface-acoustic-wave signal processor and collects 2500 spectra/s. However, the DSP-based system provides complete data sets at two wavelengths from the continuous-wave lidars.

  17. Speckle reduction process based on digital filtering and wavelet compounding in optical coherence tomography for dermatology

    Science.gov (United States)

    Gómez Valverde, Juan J.; Ortuño, Juan E.; Guerra, Pedro; Hermann, Boris; Zabihian, Behrooz; Rubio-Guivernau, José L.; Santos, Andrés.; Drexler, Wolfgang; Ledesma-Carbayo, Maria J.

    2015-07-01

    Optical Coherence Tomography (OCT) has shown a great potential as a complementary imaging tool in the diagnosis of skin diseases. Speckle noise is the most prominent artifact present in OCT images and could limit the interpretation and detection capabilities. In this work we propose a new speckle reduction process and compare it with various denoising filters with high edge-preserving potential, using several sets of dermatological OCT B-scans. To validate the performance we used a custom-designed spectral domain OCT and two different data set groups. The first group consisted in five datasets of a single B-scan captured N times (with N<20), the second were five 3D volumes of 25 Bscans. As quality metrics we used signal to noise (SNR), contrast to noise (CNR) and equivalent number of looks (ENL) ratios. Our results show that a process based on a combination of a 2D enhanced sigma digital filter and a wavelet compounding method achieves the best results in terms of the improvement of the quality metrics. In the first group of individual B-scans we achieved improvements in SNR, CNR and ENL of 16.87 dB, 2.19 and 328 respectively; for the 3D volume datasets the improvements were 15.65 dB, 3.44 and 1148. Our results suggest that the proposed enhancement process may significantly reduce speckle, increasing SNR, CNR and ENL and reducing the number of extra acquisitions of the same frame.

  18. Coherent noise reduction in digital holographic microscopy by averaging multiple holograms recorded with a multimode laser.

    Science.gov (United States)

    Pan, Feng; Yang, Lizhi; Xiao, Wen

    2017-09-04

    In digital holographic microscopy (DHM), it is undesirable to observe coherent noise in the reconstructed images. The sources of the noise are mainly the parasitic interference fringes caused by multiple reflections and the speckle pattern caused by the optical scattering on the object surface. Here we propose a noise reduction approach in DHM by averaging multiple holograms recorded with a multimode laser. Based on the periodicity of the temporal coherence of a multimode semiconductor laser, we acquire a series of holograms by changing the optical path length difference between the reference beam and object beam. Because of the use of low coherence light, we can remove the parasitic interference fringes caused by multiple reflections in the holograms. In addition, the coherent noise patterns change in this process due to the different optical paths. Therefore, the coherent noise can be reduced by averaging the multiple reconstructions with uncorrelated noise patterns. Several experiments have been carried out to validate the effectiveness of the proposed approach for coherent noise reduction in DHM. It is shown a remarkable improvement both in amplitude imaging quality and phase measurement accuracy.

  19. Linear and Nonlinear Impairment Compensation in Coherent Optical Transmission with Digital Signal Processing

    DEFF Research Database (Denmark)

    Porto da Silva, Edson

    Digital signal processing (DSP) has become one of the main enabling technologies for the physical layer of coherent optical communication networks. The DSP subsystems are used to implement several functionalities in the digital domain, from synchronization to channel equalization. Flexibility...... nonlinearity compensation, (II) spectral shaping, and (III) adaptive equalization. For (I), original contributions are presented to the study of the nonlinearity compensation (NLC) with digital backpropagation (DBP). Numerical and experimental performance investigations are shown for different application...... scenarios. Concerning (II), it is demonstrated how optical and electrical (digital) pulse shaping can be allied to improve the spectral confinement of a particular class of optical time-division multiplexing (OTDM) signals that can be used as a building block for fast signaling single-carrier transceivers...

  20. A new digital correlation flaw detection system

    International Nuclear Information System (INIS)

    Lee, B.B.; Furgason, E.S.

    1981-01-01

    A new portable digital random signal flaw detection system is described which uses a digital delay line to replace the acoustic delay line of the original random signal system. Using this new system, a comparison was made between the two types of transmit signals which have been used in previous systems--m-sequences and random signals. This comparison has not been possible with these previous correlation flaw detection systems. Results indicated that for high-speed short code operation, the m-sequences produced slightly lower range sidelobes than typical samples of a clipped random signal. For normal long code operation, results indicated that system performance is essentially equivalent in resolution and signal-to-noise ratio using either m-sequences or clipped and sampled random signals. Further results also showed that for normal long code operation, the system produces outputs equivalent in resolution to pulse-echo systems, but with the added benefit of signal-to-noise ratio enhancement

  1. Digital detection systems for projection radiography

    International Nuclear Information System (INIS)

    Schulz, R.F.

    2001-01-01

    This article gives a survey of digital X-ray detection systems for projection radiography. The different principles are compared and some general characteristics are derived. The basic conversion mechanisms in the absorption layers are described. The basic principles of solid state X-ray detectors and their general characteristics are elucidated as well as some similarities with detectors for computed tomography. Some important application and system aspects are considered. An outlook on further possible developments in this field is given. (orig.) [de

  2. Multichannel Digital Emulator of Radiation Detection Systems

    International Nuclear Information System (INIS)

    Abba, A.; Caponio, F.; Geraci, A.

    2013-06-01

    A digital system for emulating in real time signals from generic setups for radiation detection is presented. The instrument is not a pulse generator of recorded shapes but a synthesizer of random pulses compliant to programmable statistics for energy and occurrence time. Completely programmable procedures for emulation of noise, disturbances and reference level variation can be implemented. The instrument has been realized and fully tested. (authors)

  3. Ultrafast laser based coherent control methods for explosives detection

    Energy Technology Data Exchange (ETDEWEB)

    Moore, David Steven [Los Alamos National Laboratory

    2010-12-06

    The detection of explosives is a notoriously difficult problem, especially at stand-off, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring Optimal Dynamic Detection of Explosives (ODD-Ex), which exploits the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity to explosives signatures while dramatically improving specificity, particularly against matrix materials and background interferences. These goals are being addressed by operating in an optimal non-linear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked control and probe subpulses. Recent results will be presented.

  4. Magnitude Squared of Coherence to Detect Imaginary Movement

    Directory of Open Access Journals (Sweden)

    Sady Antônio Santos Filho

    2009-01-01

    Full Text Available This work investigates the Magnitude Squared of Coherence (MSC for detection of Event Related Potentials (ERPs related to left-hand index finger movement. Initially, ERP presence was examined in different brain areas. To accomplish that, 20 EEG channels were used, positioned according to the 10–20 international system. The grand average, resulting from 10 normal subjects showed, as expected, responses at frontal, central, and parietal areas, particularly evident at the central area (C3, C4, Cz. The MSC, applied to movement imagination related EEG signals, detected a consistent response in frequencies around 0.3–1 Hz (delta band, mainly at central area (C3, Cz, and C4. Ability differences in control imagination among subjects produced different detection performance. Some subjects needed up to 45 events for a detectable response, while for some others only 10 events proved sufficient. Some subjects also required two or three experimental sessions in order to achieve detectable responses. For one subject, response detection was not possible at all. However, due to brain plasticity, it is plausible to expect that training sessions (to practice movement imagination improve signal-noise ratio and lead to better detection using MSC. Results are sufficiently encouraging as to suggest further exploration of MSC for future BCI application.

  5. Detecting Topological Defect Dark Matter Using Coherent Laser Ranging System

    Science.gov (United States)

    Yang, Wanpeng; Leng, Jianxiao; Zhang, Shuangyou; Zhao, Jianye

    2016-01-01

    In the last few decades, optical frequency combs with high intensity, broad optical bandwidth, and directly traceable discrete wavelengths have triggered rapid developments in distance metrology. However, optical frequency combs to date have been limited to determine the absolute distance to an object (such as satellite missions). We propose a scheme for the detection of topological defect dark matter using a coherent laser ranging system composed of dual-combs and an optical clock via nongravitational signatures. The dark matter field, which comprises a defect, may interact with standard model particles, including quarks and photons, resulting in the alteration of their masses. Thus, a topological defect may function as a dielectric material with a distinctive frequency-depend index of refraction, which would cause the time delay of a periodic extraterrestrial or terrestrial light. When a topological defect passes through the Earth, the optical path of long-distance vacuum path is altered, this change in optical path can be detected through the coherent laser ranging system. Compared to continuous wavelength(cw) laser interferometry methods, dual-comb interferometry in our scheme excludes systematic misjudgement by measuring the absolute optical path length. PMID:27389642

  6. Miniature endoscopic optical coherence tomography for calculus detection.

    Science.gov (United States)

    Kao, Meng-Chun; Lin, Chun-Li; Kung, Che-Yen; Huang, Yi-Fung; Kuo, Wen-Chuan

    2015-08-20

    The effective treatment of periodontitis involves the detection and removal of subgingival dental calculus. However, subgingival calculus is more difficult to detect than supragingival calculus because it is firmly attached to root surfaces within periodontal pockets. To achieve a smooth root surface, clinicians often remove excessive amounts of root structure because of decreased visibility. In addition, enamel pearl, a rare type of ectopic enamel formation on the root surface, can easily be confused with dental calculus in the subgingival environment. In this study, we developed a fiber-probe swept-source optical coherence tomography (SSOCT) technique and combined it with the quantitative measurement of an optical parameter [standard deviation (SD) of the optical coherence tomography (OCT) intensity] to differentiate subgingival calculus from sound enamel, including enamel pearl. Two-dimensional circumferential images were constructed by rotating the miniprobe (0.9 mm diameter) while acquiring image lines, and the adjacent lines in each rotation were stacked to generate a three-dimensional volume. In OCT images, compared to sound enamel and enamel pearls, dental calculus showed significant differences (Pdental calculus.

  7. Simultaneous measurement of refractive index and thickness distributions using low-coherence digital holography and vertical scanning

    International Nuclear Information System (INIS)

    Watanabe, Kaho; Ohshima, Masashi; Nomura, Takanori

    2014-01-01

    The simultaneous measurement method of a refractive index distribution and a thickness distribution using low-coherence digital holography with a vertical scanning is proposed. The proposed method consists of a combination of digital holography and low-coherence interferometry. The introduction of a datum plane enables the measurement of both a refractive index distribution and a thickness distribution. By the optical experiment, the potential of the proposed method is confirmed. (paper)

  8. Digital holography for coherent fiber beam combining with a co-propagative scheme.

    Science.gov (United States)

    Antier, Marie; Larat, Christian; Lallier, Eric; Bourderionnet, Jérôme; Primot, Jérôme; Brignon, Arnaud

    2014-09-22

    We present a technique for passive coherent fiber beam combining based on digital holography. In this method, the phase errors between the fibers are compensated by the diffracted phase-conjugated -1 order of a digital hologram. Unlike previous digital holography technique, the probe beams measuring the phase errors between the fibers are co-propagating with the phase-locked signal beams. This architecture is compatible with the use of multi-stage isolated amplifying fibers. It does not require any phase calculation algorithm and its correction is collective. This concept is experimentally demonstrated with three fibers at 1.55 μm. A residual phase error of λ/20 is measured.

  9. Detecting jaundice by using digital image processing

    Science.gov (United States)

    Castro-Ramos, J.; Toxqui-Quitl, C.; Villa Manriquez, F.; Orozco-Guillen, E.; Padilla-Vivanco, A.; Sánchez-Escobar, JJ.

    2014-03-01

    When strong Jaundice is presented, babies or adults should be subject to clinical exam like "serum bilirubin" which can cause traumas in patients. Often jaundice is presented in liver disease such as hepatitis or liver cancer. In order to avoid additional traumas we propose to detect jaundice (icterus) in newborns or adults by using a not pain method. By acquiring digital images in color, in palm, soles and forehead, we analyze RGB attributes and diffuse reflectance spectra as the parameter to characterize patients with either jaundice or not, and we correlate that parameters with the level of bilirubin. By applying support vector machine we distinguish between healthy and sick patients.

  10. Reduction of parasitic interferences in digital holographic microscopy by numerically decreased coherence length

    Science.gov (United States)

    Kosmeier, S.; Langehanenberg, P.; von Bally, G.; Kemper, B.

    2012-01-01

    Due to the large coherence length of laser light, optical path length (OPL) resolution in laser based digital holographic microscopy suffers from parasitic interferences caused by multiple reflections within the experimental setup. Use of partially coherent light reduces this drawback but requires precise and stable matching of object and reference arm's OPLs and limits the spatial frequency of the interference pattern in off-axis holography. Here, we investigate if the noise properties of spectrally broadened light sources can be generated numerically. Therefore, holograms are coherently captured at different laser wavelengths and the corresponding reconstructed wave fields are numerically superimposed utilizing variable weightings. Gaussian and rectangular spectral shapes of the so synthesized field are analyzed with respect to the resulting noise level, which is quantified in OPL distributions of a reflective test target. Utilizing a Gaussian weighting, the noise level is found to be similar to the one obtained with the partially coherent light of a superluminescent diode. With a rectangular shaped synthesized spectrum, noise is reduced more efficient than with a Gaussian one. The applicability of the method in label-free cell analysis is demonstrated by quantitative phase contrast images obtained from living cancer cells.

  11. Surface Distresses Detection of Pavement Based on Digital Image Processing

    OpenAIRE

    Ouyang , Aiguo; Luo , Chagen; Zhou , Chao

    2010-01-01

    International audience; Pavement crack is the main form of early diseases of pavement. The use of digital photography to record pavement images and subsequent crack detection and classification has undergone continuous improvements over the past decade. Digital image processing has been applied to detect the pavement crack for its advantages of large amount of information and automatic detection. The applications of digital image processing in pavement crack detection, distresses classificati...

  12. Experimental demonstration of adaptive digital monitoring and compensation of chromatic dispersion for coherent DP-QPSK receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zhang, Xu; Zibar, Darko

    2011-01-01

    We experimentally demonstrate a digital signal processing (DSP)-based optical performance monitoring (OPM) algorithm for inservice monitoring of chromatic dispersion (CD) in coherent transport networks. Dispersion accumulated in 40 Gbit/s QPSK signal after 80 km of fiber transmission is successfu...... drives an adaptive digital CD equalizer. © 2011 Optical Society of America.......We experimentally demonstrate a digital signal processing (DSP)-based optical performance monitoring (OPM) algorithm for inservice monitoring of chromatic dispersion (CD) in coherent transport networks. Dispersion accumulated in 40 Gbit/s QPSK signal after 80 km of fiber transmission...

  13. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    International Nuclear Information System (INIS)

    2011-01-01

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

  14. Optical coherence tomography detection of subclinical traumatic cartilage injury.

    Science.gov (United States)

    Bear, David M; Szczodry, Michal; Kramer, Scott; Coyle, Christian H; Smolinski, Patrick; Chu, Constance R

    2010-09-01

    Posttraumatic arthritis is a major cause of disability. Current clinical imaging modalities are unable to reliably evaluate articular cartilage damage before surface breakdown, when potentially reversible changes are occurring. Optical coherence tomography (OCT) is a nondestructive imaging technology that can detect degenerative changes in articular cartilage with an intact surface. This study tests the hypothesis that OCT detects acute articular cartilage injury after impact at energy levels resulting in chondrocyte death and microstructural changes, but insufficient to produce macroscopic surface damage. Bovine osteochondral cores underwent OCT imaging and were divided into a control with no impact or were subjected to low (0.175 J) or moderate (0.35 J) energy impact. Cores were reimaged with OCT after impact and the OCT signal intensity quantified. A ratio of the superficial to deep layer intensities was calculated and compared before and after impact. Chondrocyte viability was determined 1 day after impact followed by histology and polarized microscopy. Macroscopic changes to the articular surface were not observed after low and moderate impact. The OCT signal intensity ratio demonstrated a 27% increase (P = 0.006) after low impact and a 38% increase (P = 0.001) after moderate impact. Cell death increased by 150% (P death and microscopic matrix damage. This finding supports the use of OCT to detect microstructural subsurface cartilage damage that is poorly visualized with conventional imaging.

  15. Detecting corner points from digital curves

    International Nuclear Information System (INIS)

    Sarfraz, M.

    2011-01-01

    Corners in digital images give important clues for shape representation, recognition, and analysis. Since dominant information regarding shape is usually available at the corners, they provide important features for various real life applications in the disciplines like computer vision, pattern recognition, computer graphics. Corners are the robust features in the sense that they provide important information regarding objects under translation, rotation and scale change. They are also important from the view point of understanding human perception of objects. They play crucial role in decomposing or describing the digital curves. They are also used in scale space theory, image representation, stereo vision, motion tracking, image matching, building mosaics and font designing systems. If the corner points are identified properly, a shape can be represented in an efficient and compact way with sufficient accuracy. Corner detection schemes, based on their applications, can be broadly divided into two categories: binary (suitable for binary images) and gray level (suitable for gray level images). Corner detection approaches for binary images usually involve segmenting the image into regions and extracting boundaries from those regions that contain them. The techniques for gray level images can be categorized into two classes: (a) Template based and (b) gradient based. The template based techniques utilize correlation between a sub-image and a template of a given angle. A corner point is selected by finding the maximum of the correlation output. Gradient based techniques require computing curvature of an edge that passes through a neighborhood in a gray level image. Many corner detection algorithms have been proposed in the literature which can be broadly divided into two parts. One is to detect corner points from grayscale images and other relates to boundary based corner detection. This contribution mainly deals with techniques adopted for later approach

  16. Transgene detection by digital droplet PCR.

    Directory of Open Access Journals (Sweden)

    Dirk A Moser

    Full Text Available Somatic gene therapy is a promising tool for the treatment of severe diseases. Because of its abuse potential for performance enhancement in sports, the World Anti-Doping Agency (WADA included the term 'gene doping' in the official list of banned substances and methods in 2004. Several nested PCR or qPCR-based strategies have been proposed that aim at detecting long-term presence of transgene in blood, but these strategies are hampered by technical limitations. We developed a digital droplet PCR (ddPCR protocol for Insulin-Like Growth Factor 1 (IGF1 detection and demonstrated its applicability monitoring 6 mice injected into skeletal muscle with AAV9-IGF1 elements and 2 controls over a 33-day period. A duplex ddPCR protocol for simultaneous detection of Insulin-Like Growth Factor 1 (IGF1 and Erythropoietin (EPO transgenic elements was created. A new DNA extraction procedure with target-orientated usage of restriction enzymes including on-column DNA-digestion was established. In vivo data revealed that IGF1 transgenic elements could be reliably detected for a 33-day period in DNA extracted from whole blood. In vitro data indicated feasibility of IGF1 and EPO detection by duplex ddPCR with high reliability and sensitivity. On-column DNA-digestion allowed for significantly improved target detection in downstream PCR-based approaches. As ddPCR provides absolute quantification, it ensures excellent day-to-day reproducibility. Therefore, we expect this technique to be used in diagnosing and monitoring of viral and bacterial infection, in detecting mutated DNA sequences as well as profiling for the presence of foreign genetic material in elite athletes in the future.

  17. 16 Gb/s QPSK Wireless-over-Fibre Link in 75-110GHz Band Employing Optical Heterodyne Generation and Coherent Detection

    DEFF Research Database (Denmark)

    Zibar, Darko; Sambaraju, Rakesh; Caballero Jambrina, Antonio

    2010-01-01

    We report on the first demonstration of QPSK based Wireless-over-Fibre link in 75-110GHz band with a record capacity of up to 16Gb/s. Photonic wireless signal generation by heterodyne beating of free-running lasers and baud-rate digital coherent detection are employed....

  18. Differential on-on keying: A robust non-coherent digital modulation scheme

    KAUST Repository

    Kaddoum, Georges

    2015-05-01

    A robust digital modulation scheme, called differential on-on keying (DOOK), is presented in this paper which outperforms the conventional on-off keying (OOK). In this scheme, a sinusoidal signal is transmitted during the first half of the bit duration while a replica or an inverted version of the sinusoidal signal is transmitted during the second half for logic one or logic zero, respectively. Non-coherent receiver correlates the two halves of the received signal over half bit duration to construct a decision variable. Bit error performance is analyzed over AWGN and Rayleigh fading channels and compared to the conventional OOK.

  19. Differential on-on keying: A robust non-coherent digital modulation scheme

    KAUST Repository

    Kaddoum, Georges; Ahmed, Mohammed F. A.; Al-Naffouri, Tareq Y.

    2015-01-01

    A robust digital modulation scheme, called differential on-on keying (DOOK), is presented in this paper which outperforms the conventional on-off keying (OOK). In this scheme, a sinusoidal signal is transmitted during the first half of the bit duration while a replica or an inverted version of the sinusoidal signal is transmitted during the second half for logic one or logic zero, respectively. Non-coherent receiver correlates the two halves of the received signal over half bit duration to construct a decision variable. Bit error performance is analyzed over AWGN and Rayleigh fading channels and compared to the conventional OOK.

  20. Detection of brain tumor margins using optical coherence tomography

    Science.gov (United States)

    Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier

    2018-02-01

    In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, non-cancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancer-infiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End- Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.

  1. Detecting microcalcifications in digital mammogram using wavelets

    International Nuclear Information System (INIS)

    Yang Jucheng; Park Dongsun

    2004-01-01

    Breast cancer is still one of main mortality causes in women, but the early detection can increase the chance of cure. Microcalcifications are small size structures, which can indicate the presence of cancer since they are often associated to the most different types of breast tumors. However, they very small size and the X-ray systems limitations lead to constraints to the adequate visualization of such structures, which means that the microcalcifications can be missed many times in mammogram visual examination. In addition, the human eyes are not able to distinguish minimal tonality differences, which can be another constraint when mammogram image presents poor contrast between microcalcifications and the tissues around them. Computer-aided diagnosis (CAD) schemes are being developed in order to increase the probabilities of early detection. To enhance and detect the microcalcifications in the mammograms we use the wavelets transform. From a signal processing point of view, microcalcifications are high frequency components in mammograms. Due to the multi-resolution decomposition capacity of the wavelet transform, we can decompose the image into different resolution levels which sensitive to different frequency bands. By choosing an appropriate wavelet and a right resolution level, we can effectively enhance and detect the microcalcifications in digital mammogram. In this work, we describe a new four-step method for the detection of microcalcifications: segmentation, wavelets transform processing, labeling and post-processing. The segmentation step is to split the breast area into 256x256 segments. For each segmented sub-image, wavelet transform is operated on it. For comparing study wavelet transform method, 4 typical family wavelets and 4 decomposing levels is discussed. We choose four family wavelets for detecting microcalcifications, that is, Daubechies, Biothgonai, Coieflets and Symlets wavelets, for simply, bd4, bior3.7, coif3, sym2 are chosen as the

  2. Modulation format identification enabled by the digital frequency-offset loading technique for hitless coherent transceiver.

    Science.gov (United States)

    Fu, Songnian; Xu, Zuying; Lu, Jianing; Jiang, Hexun; Wu, Qiong; Hu, Zhouyi; Tang, Ming; Liu, Deming; Chan, Calvin Chun-Kit

    2018-03-19

    We propose a blind and fast modulation format identification (MFI) enabled by the digital frequency-offset (FO) loading technique for hitless coherent transceiver. Since modulation format information is encoded to the FO distribution during digital signal processing (DSP) at the transmitter side (Tx), we can use the fast Fourier transformation based FO estimation (FFT-FOE) method to obtain the FO distribution of individual data block after constant modulus algorithm (CMA) pre-equalization at the receiver side, in order to realize non-data-aided (NDA) and fast MFI. The obtained FO can be also used for subsequent FO compensation (FOC), without additional complexity. We numerically investigate and experimentally verify the proposed MFI with high accuracy and fast format switching among 28 Gbaud dual-polarization (DP)-4/8/16/64QAM, time domain hybrid-4/16QAM, and set partitioning (SP)-128QAM. In particular, the proposed MFI brings no performance degradation, in term of tolerance of amplified spontaneous emission (ASE) noise, laser linewidth, and fiber nonlinearity. Finally, a hitless coherent transceiver enabled by the proposed MFI with switching-block of only 2048 symbols is demonstrated over 1500 km standard single mode fiber (SSMF) transmission.

  3. Joint OSNR monitoring and modulation format identification in digital coherent receivers using deep neural networks.

    Science.gov (United States)

    Khan, Faisal Nadeem; Zhong, Kangping; Zhou, Xian; Al-Arashi, Waled Hussein; Yu, Changyuan; Lu, Chao; Lau, Alan Pak Tao

    2017-07-24

    We experimentally demonstrate the use of deep neural networks (DNNs) in combination with signals' amplitude histograms (AHs) for simultaneous optical signal-to-noise ratio (OSNR) monitoring and modulation format identification (MFI) in digital coherent receivers. The proposed technique automatically extracts OSNR and modulation format dependent features of AHs, obtained after constant modulus algorithm (CMA) equalization, and exploits them for the joint estimation of these parameters. Experimental results for 112 Gbps polarization-multiplexed (PM) quadrature phase-shift keying (QPSK), 112 Gbps PM 16 quadrature amplitude modulation (16-QAM), and 240 Gbps PM 64-QAM signals demonstrate OSNR monitoring with mean estimation errors of 1.2 dB, 0.4 dB, and 1 dB, respectively. Similarly, the results for MFI show 100% identification accuracy for all three modulation formats. The proposed technique applies deep machine learning algorithms inside standard digital coherent receiver and does not require any additional hardware. Therefore, it is attractive for cost-effective multi-parameter estimation in next-generation elastic optical networks (EONs).

  4. A Deep Learning Approach to Digitally Stain Optical Coherence Tomography Images of the Optic Nerve Head.

    Science.gov (United States)

    Devalla, Sripad Krishna; Chin, Khai Sing; Mari, Jean-Martial; Tun, Tin A; Strouthidis, Nicholas G; Aung, Tin; Thiéry, Alexandre H; Girard, Michaël J A

    2018-01-01

    To develop a deep learning approach to digitally stain optical coherence tomography (OCT) images of the optic nerve head (ONH). A horizontal B-scan was acquired through the center of the ONH using OCT (Spectralis) for one eye of each of 100 subjects (40 healthy and 60 glaucoma). All images were enhanced using adaptive compensation. A custom deep learning network was then designed and trained with the compensated images to digitally stain (i.e., highlight) six tissue layers of the ONH. The accuracy of our algorithm was assessed (against manual segmentations) using the dice coefficient, sensitivity, specificity, intersection over union (IU), and accuracy. We studied the effect of compensation, number of training images, and performance comparison between glaucoma and healthy subjects. For images it had not yet assessed, our algorithm was able to digitally stain the retinal nerve fiber layer + prelamina, the RPE, all other retinal layers, the choroid, and the peripapillary sclera and lamina cribrosa. For all tissues, the dice coefficient, sensitivity, specificity, IU, and accuracy (mean) were 0.84 ± 0.03, 0.92 ± 0.03, 0.99 ± 0.00, 0.89 ± 0.03, and 0.94 ± 0.02, respectively. Our algorithm performed significantly better when compensated images were used for training (P deep learning algorithm can simultaneously stain the neural and connective tissues of the ONH, offering a framework to automatically measure multiple key structural parameters of the ONH that may be critical to improve glaucoma management.

  5. Experimental demonstration of a format-flexible single-carrier coherent receiver using data-aided digital signal processing.

    Science.gov (United States)

    Elschner, Robert; Frey, Felix; Meuer, Christian; Fischer, Johannes Karl; Alreesh, Saleem; Schmidt-Langhorst, Carsten; Molle, Lutz; Tanimura, Takahito; Schubert, Colja

    2012-12-17

    We experimentally demonstrate the use of data-aided digital signal processing for format-flexible coherent reception of different 28-GBd PDM and 4D modulated signals in WDM transmission experiments over up to 7680 km SSMF by using the same resource-efficient digital signal processing algorithms for the equalization of all formats. Stable and regular performance in the nonlinear transmission regime is confirmed.

  6. Coherent network detection of gravitational waves: the redundancy veto

    International Nuclear Information System (INIS)

    Wen Linqing; Schutz, Bernard F

    2005-01-01

    A network of gravitational wave detectors is called redundant if, given the direction to a source, the strain induced by a gravitational wave in one or more of the detectors can be fully expressed in terms of the strain induced in others in the network. Because gravitational waves have only two polarizations, any network of three or more differently oriented interferometers with similar observing bands is redundant. The three-armed LISA space interferometer has three outputs that are redundant at low frequencies. The two aligned LIGO interferometers at Hanford WA are redundant, and the LIGO detector at Livingston LA is nearly redundant with either of the Hanford detectors. Redundant networks have a powerful veto against spurious noise, a linear combination of the detector outputs that contains no gravitational wave signal. For LISA, this 'null' output is known as the Sagnac mode, and its use in discriminating between detector noise and a cosmological gravitational wave background is well understood. But the usefulness of the null veto for ground-based detector networks has been ignored until now. We show that it should make it possible to discriminate in a model-independent way between real gravitational waves and accidentally coincident non-Gaussian noise 'events' in redundant networks of two or more broadband detectors. It has been shown that with three detectors, the null output can even be used to locate the direction to the source, and then two other linear combinations of detector outputs give the optimal 'coherent' reconstruction of the two polarization components of the signal. We discuss briefly the implementation of such a detection strategy in realistic networks, where signals are weak, detector calibration is a significant uncertainty, and the various detectors may have different (but overlapping) observing bands

  7. Equalization Enhanced Phase Noise in Coherent Optical Systems with Digital Pre- and Post-Processing

    Directory of Open Access Journals (Sweden)

    Aditya Kakkar

    2016-03-01

    Full Text Available We present an extensive study of equalization enhanced phase noise (EEPN in coherent optical system for all practical electronic dispersion compensation configurations. It is shown that there are only eight practicable all-electronic impairment mitigation configurations. The non-linear and time variant analysis reveals that the existence and the cause of EEPN depend on the digital signal processing (DSP schemes. There are three schemes that in principle do not cause EEPN. Analysis further reveals the statistical equivalence of the remaining five system configurations resulting in EEPN. In three of them, EEPN is due to phase noise of the transmitting laser, while in the remaining two, EEPN is caused by the local oscillator. We provide a simple look-up table for the system designer to make an informative decision regarding practicable configuration choice and design.

  8. Digital coherent superposition of optical OFDM subcarrier pairs with Hermitian symmetry for phase noise mitigation.

    Science.gov (United States)

    Yi, Xingwen; Chen, Xuemei; Sharma, Dinesh; Li, Chao; Luo, Ming; Yang, Qi; Li, Zhaohui; Qiu, Kun

    2014-06-02

    Digital coherent superposition (DCS) provides an approach to combat fiber nonlinearities by trading off the spectrum efficiency. In analogy, we extend the concept of DCS to the optical OFDM subcarrier pairs with Hermitian symmetry to combat the linear and nonlinear phase noise. At the transmitter, we simply use a real-valued OFDM signal to drive a Mach-Zehnder (MZ) intensity modulator biased at the null point and the so-generated OFDM signal is Hermitian in the frequency domain. At receiver, after the conventional OFDM signal processing, we conduct DCS of the optical OFDM subcarrier pairs, which requires only conjugation and summation. We show that the inter-carrier-interference (ICI) due to phase noise can be reduced because of the Hermitain symmetry. In a simulation, this method improves the tolerance to the laser phase noise. In a nonlinear WDM transmission experiment, this method also achieves better performance under the influence of cross phase modulation (XPM).

  9. Digital Printing Quality Detection and Analysis Technology Based on CCD

    Science.gov (United States)

    He, Ming; Zheng, Liping

    2017-12-01

    With the help of CCD digital printing quality detection and analysis technology, it can carry out rapid evaluation and objective detection of printing quality, and can play a certain control effect on printing quality. It can be said CDD digital printing quality testing and analysis of the rational application of technology, its digital printing and printing materials for a variety of printing equipments to improve the quality of a very positive role. In this paper, we do an in-depth study and discussion based on the CCD digital print quality testing and analysis technology.

  10. Reconfigurable Digital Coherent Receiver for Metro-Access Networks Supporting Mixed Modulation Formats and Bit-rates

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Guerrero Gonzalez, Neil; Arlunno, Valeria

    2013-01-01

    A single, reconfigurable, digital coherent receiver is proposed and experimentally demonstrated for converged wireless and optical fiber transport. The capacity of reconstructing the full transmitted optical field allows for the demodulation of mixed modulation formats and bit-rates. We performed...

  11. method for ranging and noise reduction of low coherence interferometry LCI and optical coherence tomography OCT signals by parallel detection of spectral bands

    NARCIS (Netherlands)

    Boer, JF De; Tearney, G. J.; Bouma, BE

    2008-01-01

    Apparatus and method for increasing the sensitivity in the detection of optical coherence tomography and loW coher ence interferometry (“LCI”) signals by detecting a parallel set of spectral bands, each band being a unique combination of optical frequencies. The LCI broad bandwidth source is split

  12. Equalization of FBG-induced group-delay ripples penalties using a coherent receiver and digital signal processing

    NARCIS (Netherlands)

    Veljanovski, V.; Al Fiad, M.S.A.S.; Borne, van den D.; Jansen, S.L.; Wuth, T.

    2009-01-01

    We show the mitigation of fiber Bragg gratings induced group delay ripple penalties through the use of coherent detection and electronic equalizer. For 111-Gb/s POLMUX-RZDQPSK only a negligible penalty is observed after 10 cascaded FBGs.

  13. Coherent change detection and interferometric ISAR measurements in the folded compact range

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, K.W.

    1996-08-01

    A folded compact range configuration has been developed ant the Sandia National Laboratories` compact range antenna and radar-cross- section measurement facility as a means of performing indoor, environmentally-controlled, far-field simulations of synthetic aperture radar (SAR) measurements of distributed target samples (i.e. gravel, sand, etc.). The folded compact range configuration has previously been used to perform coherent-change-detection (CCD) measurements, which allow disturbances to distributed targets on the order of fractions of a wavelength to be detected. This report describes follow-on CCD measurements of other distributed target samples, and also investigates the sensitivity of the CCD measurement process to changes in the relative spatial location of the SAR sensor between observations of the target. Additionally, this report describes the theoretical and practical aspects of performing interferometric inverse-synthetic-aperture-radar (IFISAR) measurements in the folded compact range environment. IFISAR measurements provide resolution of the relative heights of targets with accuracies on the order of a wavelength. Several examples are given of digital height maps that have been generated from measurements performed at the folded compact range facility.

  14. Digital Detection and feedback Fluxgate Magnetometer

    DEFF Research Database (Denmark)

    Piil-Henriksen, J.; Merayo, José M.G.; Nielsen, Otto V

    1996-01-01

    A new full Earth's field dynamic feedback fluxgate magnetometer is described. It is based entirely on digital signal processing and digital feedback control, thereby replacing the classical second harmonic tuned analogue electronics by processor algorithms. Discrete mathematical cross......-correlation routines and substantial oversampling reduce the noise to 71 pT root-mean-square in a 0.25-10 Hz bandwidth for a full Earth's field range instrument....

  15. Initial application of digital tomosynthesis for detection of pulmonary nodules

    International Nuclear Information System (INIS)

    Sun Zhiyuan; Su Hong; Zhao Yane; Ju Bing; Chang Shuanghui; Hu Qiuju; Lu Guangming

    2010-01-01

    Objective: To discuss the value of digital tomosynthesis for detection of pulmonary nodules. Methods: Thirty patients suspected of having pulmonary nodules underwent chest radiography, digital tomosynthesis and CT examination. Above image data were transferred to postprocessing work station and were reviewed by 2 radiologists with 3 years of chest-radiology diagnosis experience in a double-blind method. The number, location and size of nodules were recorded. Then, 2 radiologists reviewed the all images once more, and discuss in consensus. The sensitivities of chest radiography and digital tomosynthesis for detection of pulmonary nodules were respectively calculated according to the CT results. Chi-square test was used for radiography, digital tomosynthesis and CT examination. Results: Of 30 patients, 21 were detected having pulmonary nodules by X-ray radiography and 9 were negative, the total number of 40 nodules was detected, while 89 nodules in 26 patients were detected by digital tomosynthesis, and only 4 patients were negative. CT demonstrated 102 nodules in 27 patients, and 3 patients were negative. Taking CT as 'gold standard', the sensitivities of X-ray radiography and digital tomosynthesis were 27.4%(28/102)and 87.2%(89/102), X 2 =4.35, P<0.05, respectively. Conclusion: Digital tomosynthesis has a high sensitivity for detection of pulmonary nodules compared with X-ray radiography, and could be an excellent and necessary supplementary technique of X-ray radiography. (authors)

  16. Applications of Telecommunication Transceiver Architectures in All-Fiber Coherent Detection Lidars

    DEFF Research Database (Denmark)

    Abari, Cyrus F.

    . As a result, the new fiber-optic technology was quickly adopted in these lidars. Although coherent detection lidars, especially all-fiber coherent detection lidars, have benefited from the technology available in coherent fiber-optic communications, a considerable gap (in both research and technology) seems...... enable the possibility for performance improvements in existing lidars but also pave the way for the application of coherent detection lidars in areas where their presence was neither plausible nor easy to realize. This thesis, composed of an introduction and four scientific paper and one manuscript...... approaches to signal processing, necessary for the estimation of mean velocity from the spectra, are discussed and the associated advantages and disadvantages such as the signal to noise ratio and signal processing overhead are discussed. The performance of the system proposed paper I is put to test...

  17. Coherent radio-frequency detection for narrowband direct comb spectroscopy.

    Science.gov (United States)

    Anstie, James D; Perrella, Christopher; Light, Philip S; Luiten, Andre N

    2016-02-22

    We demonstrate a scheme for coherent narrowband direct optical frequency comb spectroscopy. An extended cavity diode laser is injection locked to a single mode of an optical frequency comb, frequency shifted, and used as a local oscillator to optically down-mix the interrogating comb on a fast photodetector. The high spectral coherence of the injection lock generates a microwave frequency comb at the output of the photodiode with very narrow features, enabling spectral information to be further down-mixed to RF frequencies, allowing optical transmittance and phase to be obtained using electronics commonly found in the lab. We demonstrate two methods for achieving this step: a serial mode-by-mode approach and a parallel dual-comb approach, with the Cs D1 transition at 894 nm as a test case.

  18. In vitro and clinical evaluation of optical coherence tomography for the detection of subgingival calculus and root cementum.

    Science.gov (United States)

    Tsubokawa, Masaki; Aoki, Akira; Kakizaki, Sho; Taniguchi, Yoichi; Ejiri, Kenichiro; Mizutani, Koji; Koshy, Geena; Akizuki, Tatsuya; Oda, Shigeru; Sumi, Yasunori; Izumi, Yuichi

    2018-05-24

    This study evaluated the effectiveness of swept-source optical coherence tomography (ss-OCT) for detecting calculus and root cementum during periodontal therapy. Optical coherence tomography (OCT) images were taken before and after removal of subgingival calculus from extracted teeth and compared with non-decalcified histological sections. Porcine gingival sheets of various thicknesses were applied to the root surfaces of extracted teeth with calculus and OCT images were taken. OCT images were also taken before and after scaling and root planing (SRP) in human patients. In vitro, calculus was clearly detected as a white-gray amorphous structure on the root surface, which disappeared after removal. Cementum was identified as a thin, dark-gray layer. The calculus could not be clearly observed when soft tissues were present on the root surface. Clinically, supragingival calculus and cementum could be detected clearly with OCT, and subgingival calculus in the buccal cervical area of the anterior and premolar teeth was identified, which disappeared after SRP. Digital processing of the original OCT images was useful for clarifying the calculus. In conclusion, ss-OCT showed potential as a periodontal diagnostic tool for detecting cementum and subgingival calculus, although the practical applications of subgingival imaging remain limited.

  19. Detection of bladder tumors using optical coherence tomography

    Science.gov (United States)

    Pan, Yingtian; Xie, Tuqiang; Wang, Zhenguo

    2004-07-01

    This paper summarizes the engineering development of our lab for endoscopic optical coherence tomography toward the ultimate goal to image bladder micro architecture and to diagnose bladder cancers. To test the utility and potential limitations of OCT setups for bladder tumor diagnosis, we used a rat bladder cancer model to track the morphological changes following tumor growth. Image results are presented, suggesting that OCT is able to differentiate cancerous lesions from inflammatory lesions based on OCT characterizations of epithelial thickness and backscattering changes of bladder tissue.

  20. Linearity of Air-Biased Coherent Detection for Terahertz Time-Domain Spectroscopy

    DEFF Research Database (Denmark)

    Wang, Tianwu; Iwaszczuk, Krzysztof; Wrisberg, Emil Astrup

    2016-01-01

    The performance of air-biased coherent detection (ABCD) in a broadband two-color laser-induced air plasma system for terahertz time-domain spectroscopy (THz-TDS) has been investigated. Fundamental parameters of the ABCD detection, including signal-to-noise ratio (SNR), dynamic range (DR), and lin...

  1. Automated spoof-detection for fingerprints using optical coherence tomography

    CSIR Research Space (South Africa)

    Darlow, LN

    2016-05-01

    Full Text Available that they are highly separable, resulting in 100% accuracy regarding spoof-detection, with no false rejections of real fingers. This is the first attempt at fully automated spoof-detection using OCT....

  2. Digital adaptive optics for achieving space-invariant lateral resolution in optical coherence tomography

    International Nuclear Information System (INIS)

    Kumar, A.

    2015-01-01

    Optical coherence tomography (OCT) is a non-invasive optical interferometric imaging technique that provides reflectivity profiles of the sample structures with high axial resolution. The high axial resolution is due to the use of low coherence (broad-band) light source. However, the lateral resolution in OCT depends on the numerical aperture (NA) of the focusing/imaging optics and it is affected by defocus and other higher order optical aberrations induced by the imperfect optics, or by the sample itself.Hardware based adaptive optics (AO) has been successfully combined with OCT to achieve high lateral resolution in combination with high axial resolution provided by OCT. AO, which conventionally uses Shack-Hartmann wavefront sensor (SH WFS) and deformable mirror for wavefront sensing and correction respectively, can compensate for optical aberration and can enable diffraction-limited resolution in OCT. Visualization of cone photoreceptors in 3-D has been successfully demonstrated using AO-OCT. However, OCT being an interferometric imaging technique can provide access to phase information.This phase information can be exploited by digital adaptive optics (DAO) techniques to correct optical aberration in the post-processing step to obtain diffraction-limited space invariant lateral resolution throughout the image volume. Thus, the need for hardware based AO can be eliminated, which in turn can reduce the system complexity and economical cost. In the first paper of this thesis, a novel DAO method based on sub-aperture correlation is presented which is the digital equivalent of SH WFS. The advantage of this method is that it is non-iterative in nature and it does not require a priori knowledge of any system parameters such wavelength, focal length, NA or detector pixel size. For experimental proof, a FF SS OCT system was used and the sample consisted of resolution test target and a plastic plate that introduced random optical aberration. Experimental results show that

  3. Crack Length Detection by Digital Image Processing

    DEFF Research Database (Denmark)

    Lyngbye, Janus; Brincker, Rune

    1990-01-01

    It is described how digital image processing is used for measuring the length of fatigue cracks. The system is installed in a Personal Computer equipped with image processing hardware and performs automated measuring on plane metal specimens used in fatigue testing. Normally one can not achieve...... a resolution better then that of the image processing equipment. To overcome this problem an extrapolation technique is used resulting in a better resolution. The system was tested on a specimen loaded with different loads. The error σa was less than 0.031 mm, which is of the same size as human measuring...

  4. Crack Detection by Digital Image Processing

    DEFF Research Database (Denmark)

    Lyngbye, Janus; Brincker, Rune

    It is described how digital image processing is used for measuring the length of fatigue cracks. The system is installed in a Personal, Computer equipped with image processing hardware and performs automated measuring on plane metal specimens used in fatigue testing. Normally one can not achieve...... a resolution better than that of the image processing equipment. To overcome this problem an extrapolation technique is used resulting in a better resolution. The system was tested on a specimen loaded with different loads. The error σa was less than 0.031 mm, which is of the same size as human measuring...

  5. Edge-detect interpolation for direct digital periapical images

    International Nuclear Information System (INIS)

    Song, Nam Kyu; Koh, Kwang Joon

    1998-01-01

    The purpose of this study was to aid in the use of the digital images by edge-detect interpolation for direct digital periapical images using edge-deted interpolation. This study was performed by image processing of 20 digital periapical images; pixel replication, linear non-interpolation, linear interpolation, and edge-sensitive interpolation. The obtained results were as follows ; 1. Pixel replication showed blocking artifact and serious image distortion. 2. Linear interpolation showed smoothing effect on the edge. 3. Edge-sensitive interpolation overcame the smoothing effect on the edge and showed better image.

  6. Physics-Based Predictions for Coherent Change Detection Using X-Band Synthetic Aperture Radar

    Directory of Open Access Journals (Sweden)

    Mark Preiss

    2005-12-01

    Full Text Available A theoretical model is developed to describe the interferometric coherency between pairs of SAR images of rough soil surfaces. The model is derived using a dyadic form for surface reflectivity in the Kirchhoff approximation. This permits the combination of Kirchhoff theory and spotlight synthetic aperture radar (SAR image formation theory. The resulting model is used to describe the interferometric coherency between pairs of SAR images of rough soil surfaces. The theoretical model is applied to SAR images formed before and after surface changes observed by a repeat-pass SAR system. The change in surface associated with a tyre track following vehicle passage is modelled and SAR coherency estimates are obtained. Predicted coherency distributions for both the change and no-change scenarios are used to estimate receiver operator curves for the detection of the changes using a high-resolution, X-band SAR system.

  7. Photon level chemical classification using digital compressive detection

    International Nuclear Information System (INIS)

    Wilcox, David S.; Buzzard, Gregery T.; Lucier, Bradley J.; Wang Ping; Ben-Amotz, Dor

    2012-01-01

    Highlights: ► A new digital compressive detection strategy is developed. ► Chemical classification demonstrated using as few as ∼10 photons. ► Binary filters are optimal when taking few measurements. - Abstract: A key bottleneck to high-speed chemical analysis, including hyperspectral imaging and monitoring of dynamic chemical processes, is the time required to collect and analyze hyperspectral data. Here we describe, both theoretically and experimentally, a means of greatly speeding up the collection of such data using a new digital compressive detection strategy. Our results demonstrate that detecting as few as ∼10 Raman scattered photons (in as little time as ∼30 μs) can be sufficient to positively distinguish chemical species. This is achieved by measuring the Raman scattered light intensity transmitted through programmable binary optical filters designed to minimize the error in the chemical classification (or concentration) variables of interest. The theoretical results are implemented and validated using a digital compressive detection instrument that incorporates a 785 nm diode excitation laser, digital micromirror spatial light modulator, and photon counting photodiode detector. Samples consisting of pairs of liquids with different degrees of spectral overlap (including benzene/acetone and n-heptane/n-octane) are used to illustrate how the accuracy of the present digital compressive detection method depends on the correlation coefficients of the corresponding spectra. Comparisons of measured and predicted chemical classification score plots, as well as linear and non-linear discriminant analyses, demonstrate that this digital compressive detection strategy is Poisson photon noise limited and outperforms total least squares-based compressive detection with analog filters.

  8. Coherent Detection for 1550 nm, 5 Gbit/s VCSEL Based 40 km Bidirectional PON Transmission

    DEFF Research Database (Denmark)

    Jensen, Jesper Bevensee; Rodes Lopez, Roberto; Zibar, Darko

    2011-01-01

    Coherent detection of directly modulated 1550nm VCSELs in 5Gbit/s bidirectional 40km SSMF PON-links is presented. Receiver sensitivity of –37.3dBm after transmission is achieved with 30dB system margin, corresponding to 1:1024 passive powersplitting.......Coherent detection of directly modulated 1550nm VCSELs in 5Gbit/s bidirectional 40km SSMF PON-links is presented. Receiver sensitivity of –37.3dBm after transmission is achieved with 30dB system margin, corresponding to 1:1024 passive powersplitting....

  9. Coherent Change Detection with COSMO SkyMed Data-experimental Results

    OpenAIRE

    A. Mishra; D. Chaudhuri; C. Bhattacharya; Y.S. Rao

    2013-01-01

    Change detection is a technique in which we try to find changes between two acquisitions. These acquisitions can be from different platforms and sensors. Acquisition from satellite using synthetic aperture radar (SAR) is of immense interest to military applications. Satellite has the ability to peep into the enemy territory while SAR has the capability of day and night operations, being an active sensor. Coherent change detection (CCD) can be used to detect minute changes between two images. ...

  10. Digital Correlation based on Wavelet Transform for Image Detection

    International Nuclear Information System (INIS)

    Barba, L; Vargas, L; Torres, C; Mattos, L

    2011-01-01

    In this work is presented a method for the optimization of digital correlators to improve the characteristic detection on images using wavelet transform as well as subband filtering. It is proposed an approach of wavelet-based image contrast enhancement in order to increase the performance of digital correlators. The multiresolution representation is employed to improve the high frequency content of images taken into account the input contrast measured for the original image. The energy of correlation peaks and discrimination level of several objects are improved with this technique. To demonstrate the potentiality in extracting characteristics using the wavelet transform, small objects inside reference images are detected successfully.

  11. Digital PCR for detection of citrus pathogens

    Science.gov (United States)

    Citrus trees are often infected with multiple pathogens of economic importance, especially those with insect or mite vectors. Real-time/quantitative PCR (qPCR) has been used for high-throughput detection and relative quantification of pathogens; however, target reference or standards are required. I...

  12. Digital Fluxgate Magnetometer for Detection of Microvibration

    Directory of Open Access Journals (Sweden)

    Menghui Zhi

    2017-01-01

    Full Text Available In engineering practice, instruments, such as accelerometer and laser interferometer, are widely used in vibration measurement of structural parts. A method for using a triaxial fluxgate magnetometer as a microvibration sensor to measure low-frequency pendulum microvibration (not translational vibration is proposed in this paper, so as to detect vibration from low-frequency vibration sources, such as large rotating machine, large engineering structure, earthquake, and microtremor. This method provides vibration detection based on the environmental magnetic field signal to avoid increased measurement difficulty and error due to different relative positions of permanent magnet and magnetometer on the device under test (DUT when using the original magnetic measurement method. After fixedly connecting the fluxgate probe with the DUT during the test, the angular displacement due to vibration can be deduced by measuring the geomagnetic field’s magnetic induction intensity change on the orthogonal three components during the vibration. The test shows that the microvibration sensor has angular resolution of over 0.05° and maximum measuring frequency of 64 Hz. As an exploring test aimed to detect the microvibration of earth-orbiting satellite in the in-orbit process, the simulation experiment successfully provides the real-time microvibration information for attitude and orbit control subsystem.

  13. Short-coherence in-line phase-shifting infrared digital holographic microscopy for measurement of internal structure in silicon

    Science.gov (United States)

    Xi, Teli; Dou, Jiazhen; Di, Jianglei; Li, Ying; Zhang, Jiwei; Ma, Chaojie; Zhao, Jianlin

    2017-06-01

    Short-coherence in-line phase-shifting digital holographic microscopy based on Michelson interferometer is proposed to measure internal structure in silicon. In the configuration, a short-coherence infrared laser is used as the light source in order to avoid the interference formed by the reference wave and the reflected wave from the front surface of specimen. At the same time, in-line phase-shifting configuration is introduced to overcome the problem of poor resolution and large pixel size of the infrared camera and improve the space bandwidth product of the system. A specimen with staircase structure is measured by using the proposed configuration and the 3D shape distribution are given to verify the effectiveness and accuracy of the method.

  14. Sound card based digital correlation detection of weak photoelectrical signals

    International Nuclear Information System (INIS)

    Tang Guanghui; Wang Jiangcheng

    2005-01-01

    A simple and low-cost digital correlation method is proposed to investigate weak photoelectrical signals, using a high-speed photodiode as detector, which is directly connected to a programmably triggered sound card analogue-to-digital converter and a personal computer. Two testing experiments, autocorrelation detection of weak flickering signals from a computer monitor under background of noisy outdoor stray light and cross-correlation measurement of the surface velocity of a motional tape, are performed, showing that the results are reliable and the method is easy to implement

  15. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    International Nuclear Information System (INIS)

    Dekorsy, T; Taubert, R; Hudert, F; Schrenk, G; Bartels, A; Cerna, R; Kotaidis, V; Plech, A; Koehler, K; Schmitz, J; Wagner, J

    2007-01-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 10 7 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles

  16. Detecting multiple moving objects in crowded environments with coherent motion regions

    Science.gov (United States)

    Cheriyadat, Anil M.; Radke, Richard J.

    2013-06-11

    Coherent motion regions extend in time as well as space, enforcing consistency in detected objects over long time periods and making the algorithm robust to noisy or short point tracks. As a result of enforcing the constraint that selected coherent motion regions contain disjoint sets of tracks defined in a three-dimensional space including a time dimension. An algorithm operates directly on raw, unconditioned low-level feature point tracks, and minimizes a global measure of the coherent motion regions. At least one discrete moving object is identified in a time series of video images based on the trajectory similarity factors, which is a measure of a maximum distance between a pair of feature point tracks.

  17. Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion.

    Science.gov (United States)

    Dibble, Elizabeth H; Lourenco, Ana P; Baird, Grayson L; Ward, Robert C; Maynard, A Stanley; Mainiero, Martha B

    2018-01-01

    To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 × 2 (cases and controls) × 2 breasts × 2 imaging techniques × 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p .90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. • Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. • Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. • Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.

  18. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  19. High collimated coherent illumination for reconstruction of digitally calculated holograms: design and experimental realization

    Science.gov (United States)

    Morozov, Alexander; Dubinin, German; Dubynin, Sergey; Yanusik, Igor; Kim, Sun Il; Choi, Chil-Sung; Song, Hoon; Lee, Hong-Seok; Putilin, Andrey; Kopenkin, Sergey; Borodin, Yuriy

    2017-06-01

    Future commercialization of glasses-free holographic real 3D displays requires not only appropriate image quality but also slim design of backlight unit and whole display device to match market needs. While a lot of research aimed to solve computational issues of forming Computer Generated Holograms for 3D Holographic displays, less focus on development of backlight units suitable for 3D holographic display applications with form-factor of conventional 2D display systems. Thereby, we report coherent backlight unit for 3D holographic display with thickness comparable to commercially available 2D displays (cell phones, tablets, laptops, etc.). Coherent backlight unit forms uniform, high-collimated and effective illumination of spatial light modulator. Realization of such backlight unit is possible due to holographic optical elements, based on volume gratings, constructing coherent collimated beam to illuminate display plane. Design, recording and measurement of 5.5 inch coherent backlight unit based on two holographic optical elements are presented in this paper.

  20. Digital holographic reconstruction detection of localized corrosion arising from scratches

    Directory of Open Access Journals (Sweden)

    LIANG WANG

    2010-04-01

    Full Text Available In this study, electrochemical methods and the digital holographic reconstruction technique were combined to detect the localized scratch-induced corrosion process of Alloy 690 in 0.50 mol dm-3 H2SO4 containing 0.10 mol dm-3 NaCl. The numerical reconstruction method has been proved to be an effective technique to detect changes of solution concentration. One can obtain direct information from the reconstructed images and capture subtle more revealing changes. It provides a method to detect localized corrosion arising from scratches.

  1. Optimal non-coherent data detection for massive SIMO wireless systems: A polynomial complexity solution

    KAUST Repository

    Alshamary, Haider Ali Jasim

    2016-01-04

    © 2015 IEEE. This paper considers the joint maximum likelihood (ML) channel estimation and data detection problem for massive SIMO (single input multiple output) wireless systems. We propose efficient algorithms achieving the exact ML non-coherent data detection, for both constant-modulus constellations and nonconstant-modulus constellations. Despite a large number of unknown channel coefficients in massive SIMO systems, we show that the expected computational complexity is linear in the number of receive antennas and polynomial in channel coherence time. To the best of our knowledge, our algorithms are the first efficient algorithms to achieve the exact joint ML channel estimation and data detection performance for massive SIMO systems with general constellations. Simulation results show our algorithms achieve considerable performance gains at a low computational complexity.

  2. Optimal non-coherent data detection for massive SIMO wireless systems: A polynomial complexity solution

    KAUST Repository

    Alshamary, Haider Ali Jasim; Al-Naffouri, Tareq Y.; Zaib, Alam; Xu, Weiyu

    2016-01-01

    © 2015 IEEE. This paper considers the joint maximum likelihood (ML) channel estimation and data detection problem for massive SIMO (single input multiple output) wireless systems. We propose efficient algorithms achieving the exact ML non-coherent data detection, for both constant-modulus constellations and nonconstant-modulus constellations. Despite a large number of unknown channel coefficients in massive SIMO systems, we show that the expected computational complexity is linear in the number of receive antennas and polynomial in channel coherence time. To the best of our knowledge, our algorithms are the first efficient algorithms to achieve the exact joint ML channel estimation and data detection performance for massive SIMO systems with general constellations. Simulation results show our algorithms achieve considerable performance gains at a low computational complexity.

  3. Digital tripwire: a small automated human detection system

    Science.gov (United States)

    Fischer, Amber D.; Redd, Emmett; Younger, A. Steven

    2009-05-01

    A low cost, lightweight, easily deployable imaging sensor that can dependably discriminate threats from other activities within its field of view and, only then, alert the distant duty officer by transmitting a visual confirmation of the threat would provide a valuable asset to modern defense. At present, current solutions suffer from a multitude of deficiencies - size, cost, power endurance, but most notably, an inability to assess an image and conclude that it contains a threat. The human attention span cannot maintain critical surveillance over banks of displays constantly conveying such images from the field. DigitalTripwire is a small, self-contained, automated human-detection system capable of running for 1-5 days on two AA batteries. To achieve such long endurance, the DigitalTripwire system utilizes an FPGA designed with sleep functionality. The system uses robust vision algorithms, such as a partially unsupervised innovative backgroundmodeling algorithm, which employ several data reduction strategies to operate in real-time, and achieve high detection rates. When it detects human activity, either mounted or dismounted, it sends an alert including images to notify the command center. In this paper, we describe the hardware and software design of the DigitalTripwire system. In addition, we provide detection and false alarm rates across several challenging data sets demonstrating the performance of the vision algorithms in autonomously analyzing the video stream and classifying moving objects into four primary categories - dismounted human, vehicle, non-human, or unknown. Performance results across several challenging data sets are provided.

  4. Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sarvana G. [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep01@gmail.com [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Khandelwal, Niranjan; Gupta, Pankaj [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Gupta, Dheeraj; Aggarwal, Ashutosh Nath [Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Bansal, Subash Chand [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India)

    2015-07-15

    Highlights: • Accuracy of digital tomosynthesis for nodule detection is substantially higher. • Improvement in diagnostic accuracy is most pronounced for nodules <10 mm. • There is five times increase in radiation dose compared to DR. - Abstract: Objective: Digital tomosynthesis (DT) and dual-energy subtraction digital radiography (DES-DR) are known to perform better than conventional radiography in the detection of pulmonary nodules. Yet the comparative diagnostic performances of DT, DES-DR and digital radiography (DR) is not known. The present study compares the diagnostic performances of DT, DES-DR and DR in detecting pulmonary nodules. Subjects and methods: The institutional Review Board approved the study and informed written consent was obtained. Fifty-five patients (30 with pulmonary nodules, 25 with non-nodular focal chest pathology) were included in the study. DT and DES-DR were performed within14 days of MDCT. Composite images acquired at high kVp as part of DES-DR were used as DR images. Images were analyzed for presence of nodules and calcification in nodules. Interpretations were assigned confidence levels from 1 to 5 according to Five-Point rating scale. Areas under the receiver operating characteristic curves were compared using Z test. Results: A total of 110 (88 non-calcified, 22 calcified) nodules were identified on MDCT. For detection of nodules, DR showed cumulative sensitivity and specificity of 25.45% and 67.97%, respectively. DT showed a cumulative sensitivity and specificity of 60.9% and 85.07%, respectively. The performance was significantly better than DR (p < 0.003). DES-DR showed sensitivity and specificity of 27.75% and 82.64%, not statistically different from those of DR (p—0.92). In detection of calcification, there was no statistically significant difference between DT, DES-DR and DR. Conclusions: DT performs significantly better than DES-DR and DR at the cost of moderate increase in radiation dose.

  5. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    Science.gov (United States)

    2008-06-01

    of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B, all the FPs...query ROI of unknown pathology , all other ROIs generated from that specific subject’s reconstructed volumes were excluded from the KB. For scheme B...Qian, L. Li, and L.P. Clarke, "Image feature extraction for mass detection in digital mammography: Influence of wavelet analysis." Med. Phys. 26

  6. Early detection of tooth wear by en-face optical coherence tomography

    Science.gov (United States)

    Mărcăuteanu, Corina; Negrutiu, Meda; Sinescu, Cosmin; Demjan, Eniko; Hughes, Mike; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.

    2009-02-01

    Excessive dental wear (pathological attrition and/or abfractions) is a frequent complication in bruxing patients. The parafunction causes heavy occlusal loads. The aim of this study is the early detection and monitoring of occlusal overload in bruxing patients. En-face optical coherence tomography was used for investigating and imaging of several extracted tooth, with a normal morphology, derived from patients with active bruxism and from subjects without parafunction. We found a characteristic pattern of enamel cracks in patients with first degree bruxism and with a normal tooth morphology. We conclude that the en-face optical coherence tomography is a promising non-invasive alternative technique for the early detection of occlusal overload, before it becomes clinically evident as tooth wear.

  7. Optimization of the digital Silicon Photomultiplier for Cherenkov light detection

    International Nuclear Information System (INIS)

    Frach, T

    2012-01-01

    The Silicon Photomultiplier is a promising alternative to fast vacuum photodetectors. We developed a fully digital implementation of the Silicon Photomultiplier. The sensor is based on a single photon avalanche photodiode (SPAD) integrated in a standard CMOS process. Photons are detected directly by sensing the voltage at the SPAD anode using a dedicated cell electronics block next to each diode. This block also contains active quenching and recharge circuits as well as a one bit memory for the selective inhibit of detector cells. A balanced trigger network is used to propagate the trigger signal from all cells to the integrated time-to-digital converter. Photons are detected and counted as digital signals, thus making the sensor less susceptible to temperature variations and electronic noise. The integration with CMOS logic has the added benefit of low power consumption and possible integration of data post-processing in the sensor. In this paper, we discuss the sensor architecture together with its characteristics, and its possible optimizations for applications requiring the detection of Cherenkov light.

  8. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    OpenAIRE

    Megan B. Goodman; Ari Ziskind

    2015-01-01

    Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT) and fundus auto fluorescence (FAF) images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ), referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B co...

  9. Registering coherent change detection products associated with large image sets and long capture intervals

    Science.gov (United States)

    Perkins, David Nikolaus; Gonzales, Antonio I

    2014-04-08

    A set of co-registered coherent change detection (CCD) products is produced from a set of temporally separated synthetic aperture radar (SAR) images of a target scene. A plurality of transformations are determined, which transformations are respectively for transforming a plurality of the SAR images to a predetermined image coordinate system. The transformations are used to create, from a set of CCD products produced from the set of SAR images, a corresponding set of co-registered CCD products.

  10. Charge coupled devices for detection of coherent neutrino-nucleus scattering

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Moroni, Guillermo; Estrada, Juan; Paolini, Eduardo E.; Cancelo, Gustavo; Tiffenberg, Javier; Molina, Jorge

    2015-04-01

    In this article the feasibility of using charge coupled devices (CCD) to detect low-energy neutrinos through their coherent scattering with nuclei is analyzed. The detection of neutrinos through this standard model process has been elusive because of the small energy deposited in such interaction. Typical particle detectors have thresholds of a few keV, and most of the energy deposition expected from coherent scattering is well below this level. The CCD detectors discussed in this paper can operate at a threshold of approximately 30 eV, making them ideal for observing this signal. On a CCD array of 500 g located next to a power nuclear reactor the number of coherent scattering events expected is about 3000 events/year. Our results shows that a detection with a confidence level of 99% can be reached within 16 days of continuous operation; with the current 52 g detector prototype this time lapse extends to five months.

  11. Computerized detection of pneumothorax on digital chest radiographs

    International Nuclear Information System (INIS)

    Sanada, S.; Doi, K.; MacMahon, H.; Montner, S.M.

    1990-01-01

    This paper reports on neumothoraces that are clinically important abnormalities that usually appear as a subtle, fine line pattern on chest radiographs. We are developing a computer vision system for automated detection of pneumothorax to aid radiologists diagnosis. Chest images were digitized with a 0.175-mm pixel size, yielding a 2,000 x 2,430 matrix size, and 10 bits of gray scale. After indentification of the lung regions, an edge detection filter was employed in the apical areas to enhance a pneumothorax pattern. Ribs were detected with a technique based on statistical analysis of edge gradients and their orientations. Points located on a curved line suggestive of a pneumothorax in this enhanced image were detected with a Hough transform

  12. Coherent population trapping magnetometer by differential detecting magneto–optic rotation effect

    International Nuclear Information System (INIS)

    Zhang Fan; Tian Yuan; Zhang Yi; Gu Si-Hong

    2016-01-01

    A pocket coherent population trapping (CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated. Using the differential detecting magneto–optic rotation effect, a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained. The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order, and the ability to detect weak magnetic fields is extended one-fold. Therefore, the proposed scheme is suited to realize a pocket-size CPT magnetometer. (paper)

  13. Coherent detection passive optical access network enabling converged delivery of broadcast and dedicated broadband services

    DEFF Research Database (Denmark)

    Osadchiy, Alexey Vladimirovich; Prince, Kamau; Guerrero Gonzalez, Neil

    2011-01-01

    We propose a passive optical network architecture based on coherent detection for converged delivery of broadcast services from a dedicated remote broadcast server and user-specific services from a local central office. We experimentally demonstrate this architecture with mixed traffic types....... The broadcast channels were transmitted over 78 km of single mode fiber to a central office where they were multiplexed with the unicast channels for further fiber transmission over 34-km to reach the access network. Successful detection of all channels is demonstrated....

  14. Fast microwave detection system for coherent synchrotron radiation study at KEK: Accelerator test facility

    International Nuclear Information System (INIS)

    Aryshev, A.; Araki, S.; Karataev, P.; Naito, T.; Terunuma, N.; Urakawa, J.

    2007-01-01

    A fast room temperature microwave detection system based on the Schottky Barrier-diode detector was created at the KEK ATF (Accelerator Test Facility). It was tested using Coherent Synchrotron Radiation (CSR) generated by the 1.28 GeV electron beam in the damping ring. The speed performance of the detection system was checked by observing the CSR from a multi-bunch (2.8 ns bunch separation time) beam. The theoretical estimations of CSR power yield from an edge of bending magnet as well as new injection tuning method are presented. A very high sensitivity of CSR power yield to the longitudinal electron distribution in a bunch is discussed

  15. Early cell death detection with digital holographic microscopy.

    Directory of Open Access Journals (Sweden)

    Nicolas Pavillon

    Full Text Available BACKGROUND: Digital holography provides a non-invasive measurement of the quantitative phase shifts induced by cells in culture, which can be related to cell volume changes. It has been shown previously that regulation of cell volume, in particular as it relates to ionic homeostasis, is crucially involved in the activation/inactivation of the cell death processes. We thus present here an application of digital holographic microscopy (DHM dedicated to early and label-free detection of cell death. METHODS AND FINDINGS: We provide quantitative measurements of phase signal obtained on mouse cortical neurons, and caused by early neuronal cell volume regulation triggered by excitotoxic concentrations of L-glutamate. We show that the efficiency of this early regulation of cell volume detected by DHM, is correlated with the occurrence of subsequent neuronal death assessed with the widely accepted trypan blue method for detection of cell viability. CONCLUSIONS: The determination of the phase signal by DHM provides a simple and rapid optical method for the early detection of cell death.

  16. Value of digital radiography in expiration in detection of pneumothorax

    International Nuclear Information System (INIS)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D.; Schulz, U.

    2014-01-01

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  17. Experimental Adaptive Digital Performance Monitoring for Optical DP-QPSK Coherent Receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zhang, Xu; Zibar, Darko

    2011-01-01

    We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module.......We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module....

  18. Low-cost digital GPS receiver with software carrier detection

    Science.gov (United States)

    Wolf, M. H.

    1988-08-01

    The satellite navigation system global positioning system (GPS) will play a major role in the field of navigation. It will be able to compete with all previously existing radio navigation systems. Low-cost receivers will be built for a number of civilian users, such as general aviation, sea and land navigation. To permit production at low cost for the civil market, a new technique for a C/A (course and acquisition) code receiver has been developed. All the signal detecting and processing is carried out with the digital signal processing software in a Texas Instruments TMS 320C10. The advantage of this method is that complex functions can be effected in a computer program instead of in analog or digital circuits. This reduces the costs of the parts used in the receiver and also avoids calibration. Taken together, these two features greatly reduce the price of a navigation set. This paper discusses the underlying principles leading to this new receiver.

  19. A spatial approach of magnitude-squared coherence applied to selective attention detection.

    Science.gov (United States)

    Bonato Felix, Leonardo; de Souza Ranaudo, Fernando; D'affonseca Netto, Aluizio; Ferreira Leite Miranda de Sá, Antonio Mauricio

    2014-05-30

    Auditory selective attention is the human ability of actively focusing in a certain sound stimulus while avoiding all other ones. This ability can be used, for example, in behavioral studies and brain-machine interface. In this work we developed an objective method - called Spatial Coherence - to detect the side where a subject is focusing attention to. This method takes into consideration the Magnitude Squared Coherence and the topographic distribution of responses among electroencephalogram electrodes. The individuals were stimulated with amplitude-modulated tones binaurally and were oriented to focus attention to only one of the stimuli. The results indicate a contralateral modulation of ASSR in the attention condition and are in agreement with prior studies. Furthermore, the best combination of electrodes led to a hit rate of 82% for 5.03 commands per minute. Using a similar paradigm, in a recent work, a maximum hit rate of 84.33% was achieved, but with a greater a classification time (20s, i.e. 3 commands per minute). It seems that Spatial Coherence is a useful technique for detecting focus of auditory selective attention. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Precision of coherence analysis to detect cerebral autoregulation by near-infrared spectroscopy in preterm infants

    DEFF Research Database (Denmark)

    Hahn, GH; Christensen, KB; Leung, TS

    2010-01-01

    Coherence between spontaneous fluctuations in arterial blood pressure (ABP) and the cerebral near-infrared spectroscopy signal can detect cerebral autoregulation. Because reliable measurement depends on signals with high signal-to-noise ratio, we hypothesized that coherence is more precisely...... determined when fluctuations in ABP are large rather than small. Therefore, we investigated whether adjusting for variability in ABP (variabilityABP) improves precision. We examined the impact of variabilityABP within the power spectrum in each measurement and between repeated measurements in preterm infants....... We also examined total monitoring time required to discriminate among infants with a simulation study. We studied 22 preterm infants (GAABP within the power spectrum did not improve the precision. However, adjusting...

  1. Automatic Microaneurysm Detection and Characterization Through Digital Color Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Charles; Veras, Rodrigo; Ramalho, Geraldo; Medeiros, Fatima; Ushizima, Daniela

    2008-08-29

    Ocular fundus images can provide information about retinal, ophthalmic, and even systemic diseases such as diabetes. Microaneurysms (MAs) are the earliest sign of Diabetic Retinopathy, a frequently observed complication in both type 1 and type 2 diabetes. Robust detection of MAs in digital color fundus images is critical in the development of automated screening systems for this kind of disease. Automatic grading of these images is being considered by health boards so that the human grading task is reduced. In this paper we describe segmentation and the feature extraction methods for candidate MAs detection.We show that the candidate MAs detected with the methodology have been successfully classified by a MLP neural network (correct classification of 84percent).

  2. Independent component analysis based digital signal processing in coherent optical fiber communication systems

    Science.gov (United States)

    Li, Xiang; Luo, Ming; Qiu, Ying; Alphones, Arokiaswami; Zhong, Wen-De; Yu, Changyuan; Yang, Qi

    2018-02-01

    In this paper, channel equalization techniques for coherent optical fiber transmission systems based on independent component analysis (ICA) are reviewed. The principle of ICA for blind source separation is introduced. The ICA based channel equalization after both single-mode fiber and few-mode fiber transmission for single-carrier and orthogonal frequency division multiplexing (OFDM) modulation formats are investigated, respectively. The performance comparisons with conventional channel equalization techniques are discussed.

  3. Detecting gravitational waves from inspiraling binaries with a network of detectors: Coherent versus coincident strategies

    International Nuclear Information System (INIS)

    Mukhopadhyay, Himan; Dhurandhar, Sanjeev; Sago, Norichika; Tagoshi, Hideyuki; Takahashi, Hirotaka; Kanda, Nobuyuki

    2006-01-01

    We compare two strategies of multidetector detection of compact binary inspiral signals, namely, the coincidence and the coherent. For simplicity we consider here two identical detectors having the same power spectral density of noise, that of initial LIGO, located in the same place and having the same orientation. We consider the cases of independent noise as well as that of correlated noise. The coincident strategy involves separately making two candidate event lists, one for each detector, and from these choosing those pairs of events from the two lists which lie within a suitable parameter window, which then are called coincidence detections. The coherent strategy on the other hand involves combining the data phase coherently, so as to obtain a single network statistic which is then compared with a single threshold. Here we attempt to shed light on the question as to which strategy is better. We compare the performances of the two methods by plotting the receiver operating characteristics (ROC) for the two strategies. Several of the results are obtained analytically in order to gain insight. Further we perform numerical simulations in order to determine certain parameters in the analytic formulae and thus obtain the final complete results. We consider here several cases from the relatively simple to the astrophysically more relevant in order to establish our results. The bottom line is that the coherent strategy although more computationally expensive in general than the coincidence strategy, is superior to the coincidence strategy--considerably less false dismissal probability for the same false alarm probability in the viable false alarm regime

  4. Reproducibility of Computer-Aided Detection Marks in Digital Mammography

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Kim, Sun Mi; Im, Jung Gi; Cha, Joo Hee

    2007-01-01

    To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. A CAD system was applied preoperatively to the fulfilled digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33 83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications

  5. Performance improvement of coherent free-space optical communication with quadrature phase-shift keying modulation using digital phase estimation.

    Science.gov (United States)

    Li, Xueliang; Geng, Tianwen; Ma, Shuang; Li, Yatian; Gao, Shijie; Wu, Zhiyong

    2017-06-01

    The performance of coherent free-space optical (CFSO) communication with phase modulation is limited by both phase fluctuations and intensity scintillations induced by atmospheric turbulence. To improve the system performance, one effective way is to use digital phase estimation. In this paper, a CFSO communication system with quadrature phase-shift keying modulation is studied. With consideration of the effects of log-normal amplitude fluctuations and Gauss phase fluctuations, a two-stage Mth power carrier phase estimation (CPE) scheme is proposed. The simulation results show that the phase noise can be suppressed greatly by this scheme, and the system symbol error rate performance with the two-stage Mth power CPE can be three orders lower than that of the single-stage Mth power CPE. Therefore, the two-stage CPE we proposed can contribute to the performance improvements of the CFSO communication system and has determinate guidance sense to its actual application.

  6. An ethical assessment model for digital disease detection technologies.

    Science.gov (United States)

    Denecke, Kerstin

    2017-09-20

    Digital epidemiology, also referred to as digital disease detection (DDD), successfully provided methods and strategies for using information technology to support infectious disease monitoring and surveillance or understand attitudes and concerns about infectious diseases. However, Internet-based research and social media usage in epidemiology and healthcare pose new technical, functional and formal challenges. The focus of this paper is on the ethical issues to be considered when integrating digital epidemiology with existing practices. Taking existing ethical guidelines and the results from the EU project M-Eco and SORMAS as starting point, we develop an ethical assessment model aiming at providing support in identifying relevant ethical concerns in future DDD projects. The assessment model has four dimensions: user, application area, data source and methodology. The model supports in becoming aware, identifying and describing the ethical dimensions of DDD technology or use case and in identifying the ethical issues on the technology use from different perspectives. It can be applied in an interdisciplinary meeting to collect different viewpoints on a DDD system even before the implementation starts and aims at triggering discussions and finding solutions for risks that might not be acceptable even in the development phase. From the answers, ethical issues concerning confidence, privacy, data and patient security or justice may be judged and weighted.

  7. ECG Based Heart Arrhythmia Detection Using Wavelet Coherence and Bat Algorithm

    Science.gov (United States)

    Kora, Padmavathi; Sri Rama Krishna, K.

    2016-12-01

    Atrial fibrillation (AF) is a type of heart abnormality, during the AF electrical discharges in the atrium are rapid, results in abnormal heart beat. The morphology of ECG changes due to the abnormalities in the heart. This paper consists of three major steps for the detection of heart diseases: signal pre-processing, feature extraction and classification. Feature extraction is the key process in detecting the heart abnormality. Most of the ECG detection systems depend on the time domain features for cardiac signal classification. In this paper we proposed a wavelet coherence (WTC) technique for ECG signal analysis. The WTC calculates the similarity between two waveforms in frequency domain. Parameters extracted from WTC function is used as the features of the ECG signal. These features are optimized using Bat algorithm. The Levenberg Marquardt neural network classifier is used to classify the optimized features. The performance of the classifier can be improved with the optimized features.

  8. Magneto-motive detection of tissue-based macrophages by differential phase optical coherence tomography.

    Science.gov (United States)

    Oh, Junghwan; Feldman, Marc D; Kim, Jihoon; Kang, Hyun Wook; Sanghi, Pramod; Milner, Thomas E

    2007-03-01

    A novel method to detect tissue-based macrophages using a combination of superparamagnetic iron oxide (SPIO) nanoparticles and differential phase optical coherence tomography (DP-OCT) with an external oscillating magnetic field is reported. Magnetic force acting on iron-laden tissue-based macrophages was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially focused and increased magnetic flux density. Nanoparticle motion was detected with DP-OCT, which can detect tissue movement with nanometer resolution. Frequency response of iron-laden tissue movement was twice the modulation frequency since the magnetic force is proportional to the product of magnetic flux density and gradient. Results of our experiments indicate that DP-OCT can be used to identify tissue-based macrophage when excited by an external focused oscillating magnetic field. (c) 2007 Wiley-Liss, Inc

  9. Automated detection of photoreceptor disruption in mild diabetic retinopathy on volumetric optical coherence tomography.

    Science.gov (United States)

    Wang, Zhuo; Camino, Acner; Zhang, Miao; Wang, Jie; Hwang, Thomas S; Wilson, David J; Huang, David; Li, Dengwang; Jia, Yali

    2017-12-01

    Diabetic retinopathy is a pathology where microvascular circulation abnormalities ultimately result in photoreceptor disruption and, consequently, permanent loss of vision. Here, we developed a method that automatically detects photoreceptor disruption in mild diabetic retinopathy by mapping ellipsoid zone reflectance abnormalities from en face optical coherence tomography images. The algorithm uses a fuzzy c-means scheme with a redefined membership function to assign a defect severity level on each pixel and generate a probability map of defect category affiliation. A novel scheme of unsupervised clustering optimization allows accurate detection of the affected area. The achieved accuracy, sensitivity and specificity were about 90% on a population of thirteen diseased subjects. This method shows potential for accurate and fast detection of early biomarkers in diabetic retinopathy evolution.

  10. Artificial neural network techniques to improve the ability of optical coherence tomography to detect optic neuritis.

    Science.gov (United States)

    Garcia-Martin, Elena; Herrero, Raquel; Bambo, Maria P; Ara, Jose R; Martin, Jesus; Polo, Vicente; Larrosa, Jose M; Garcia-Feijoo, Julian; Pablo, Luis E

    2015-01-01

    To analyze the ability of Spectralis optical coherence tomography (OCT) to detect multiple sclerosis (MS) and to distinguish MS eyes with antecedent optic neuritis (ON). To analyze the capability of artificial neural network (ANN) techniques to improve the diagnostic precision. MS patients and controls were enrolled (n = 217). OCT was used to determine the 768 retinal nerve fiber layer thicknesses. Sensitivity and specificity were evaluated to test the ability of OCT to discriminate between MS and healthy eyes, and between MS with and without antecedent ON using ANN. Using ANN technique multilayer perceptrons, OCT could detect MS with a sensitivity of 89.3%, a specificity of 87.6%, and a diagnostic precision of 88.5%. Compared with the OCT-provided parameters, the ANN had a better sensitivity-specificity balance. ANN technique improves the capability of Spectralis OCT to detect MS disease and to distinguish MS eyes with or without antecedent ON.

  11. Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field.

    Science.gov (United States)

    Zhang, Xinbo; Dastiridou, Anna; Francis, Brian A; Tan, Ou; Varma, Rohit; Greenfield, David S; Schuman, Joel S; Huang, David

    2017-12-01

    To compare longitudinal glaucoma progression detection using optical coherence tomography (OCT) and visual field (VF). Validity assessment. We analyzed subjects with more than 4 semi-annual follow-up visits (every 6 months) in the multicenter Advanced Imaging for Glaucoma Study. Fourier-domain optical coherence tomography (OCT) was used to map the thickness of the peripapillary retinal nerve fiber layer (NFL) and ganglion cell complex (GCC). OCT-based progression detection was defined as a significant negative trend for either NFL or GCC. VF progression was reached if either the event or trend analysis reached significance. The analysis included 356 glaucoma suspect/preperimetric glaucoma (GS/PPG) eyes and 153 perimetric glaucoma (PG) eyes. Follow-up length was 54.1 ± 16.2 months for GS/PPG eyes and 56.7 ± 16.0 for PG eyes. Progression was detected in 62.1% of PG eyes and 59.8% of GS/PPG eyes by OCT, significantly (P glaucoma. While the utility of NFL declines in advanced glaucoma, GCC remains a sensitive progression detector from early to advanced stages. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A New Maximum-Likelihood Change Estimator for Two-Pass SAR Coherent Change Detection.

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Daniel E.; Yocky, David A.; Jakowatz, Charles V,

    2014-09-01

    In this paper, we derive a new optimal change metric to be used in synthetic aperture RADAR (SAR) coherent change detection (CCD). Previous CCD methods tend to produce false alarm states (showing change when there is none) in areas of the image that have a low clutter-to-noise power ratio (CNR). The new estimator does not suffer from this shortcoming. It is a surprisingly simple expression, easy to implement, and is optimal in the maximum-likelihood (ML) sense. The estimator produces very impressive results on the CCD collects that we have tested.

  13. Electric field detection of coherent synchrotron radiation in a storage ring generated using laser bunch slicing

    International Nuclear Information System (INIS)

    Katayama, I.; Shimosato, H.; Bito, M.; Furusawa, K.; Adachi, M.; Zen, H.; Kimura, S.; Katoh, M.; Shimada, M.; Yamamoto, N.; Hosaka, M.; Ashida, M.

    2012-01-01

    The electric field of coherent synchrotron radiation (CSR) generated by laser bunch slicing in a storage ring has been detected by an electro-optic sampling method. The gate pulses for sampling are sent through a large-mode-area photonic-crystal fiber. The observed electric field profile of the CSR is in good agreement with the spectrum of the CSR observed using Fourier transform far-infrared spectrometry, indicating good phase stability in the CSR. The longitudinal density profiles of electrons modulated by laser pulses were evaluated from the electric field profile.

  14. Detection of pH-induced aggregation of "smart" gold nanoparticles with photothermal optical coherence tomography.

    Science.gov (United States)

    Xiao, Peng; Li, Qingyun; Joo, Yongjoon; Nam, Jutaek; Hwang, Sekyu; Song, Jaejung; Kim, Sungjee; Joo, Chulmin; Kim, Ki Hean

    2013-11-01

    We report the feasibility of a novel contrast agent, namely "smart" gold nanoparticles (AuNPs), in the detection of cancer cells with photothermal optical coherence tomography (PT-OCT). "Smart" AuNPs form aggregation in low pH condition, which is typical for cancer cells, and this aggregation results in a shift of their absorption spectrum. A PT-OCT system was developed to detect this pH-induced aggregation by combining an OCT light source and a laser with 660 nm in wavelength for photothermal excitation. Optical detection of pH-induced aggregation was tested with solution samples at two different pH conditions. An increase in optical path length (OPL) variation was measured at mild acidic condition, while there was not much change at neutral condition. Detection of cancer cells was tested with cultured cell samples. HeLa and fibroblast cells, as cancer and normal cells respectively, were incubated with "smart" gold nanoparticles and measured with PT-OCT. An elevated OPL variation signal was detected with the HeLa cells while not much of a signal was detected with the fibroblast cells. With the novel optical property of "smart" AuNPs and high sensitivity of PT-OCT, this technique is promising for cancer cell detection.

  15. Evaluation of hybrids algorithms for mass detection in digitalized mammograms

    International Nuclear Information System (INIS)

    Cordero, Jose; Garzon Reyes, Johnson

    2011-01-01

    The breast cancer remains being a significant public health problem, the early detection of the lesions can increase the success possibilities of the medical treatments. The mammography is an image modality effective to early diagnosis of abnormalities, where the medical image is obtained of the mammary gland with X-rays of low radiation, this allows detect a tumor or circumscribed mass between two to three years before that it was clinically palpable, and is the only method that until now achieved reducing the mortality by breast cancer. In this paper three hybrids algorithms for circumscribed mass detection on digitalized mammograms are evaluated. In the first stage correspond to a review of the enhancement and segmentation techniques used in the processing of the mammographic images. After a shape filtering was applied to the resulting regions. By mean of a Bayesian filter the survivors regions were processed, where the characteristics vector for the classifier was constructed with few measurements. Later, the implemented algorithms were evaluated by ROC curves, where 40 images were taken for the test, 20 normal images and 20 images with circumscribed lesions. Finally, the advantages and disadvantages in the correct detection of a lesion of every algorithm are discussed.

  16. Coherent detectors

    International Nuclear Information System (INIS)

    Lawrence, C R; Church, S; Gaier, T; Lai, R; Ruf, C; Wollack, E

    2009-01-01

    Coherent systems offer significant advantages in simplicity, testability, control of systematics, and cost. Although quantum noise sets the fundamental limit to their performance at high frequencies, recent breakthroughs suggest that near-quantum-limited noise up to 150 or even 200 GHz could be realized within a few years. If the demands of component separation can be met with frequencies below 200 GHz, coherent systems will be strong competitors for a space CMB polarization mission. The rapid development of digital correlator capability now makes space interferometers with many hundreds of elements possible. Given the advantages of coherent interferometers in suppressing systematic effects, such systems deserve serious study.

  17. Coherent detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, C R [M/C 169-327, Jet Propulsion Laboratory, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Church, S [Room 324 Varian Physics Bldg, 382 Via Pueblo Mall, Stanford, CA 94305-4060 (United States); Gaier, T [M/C 168-314, Jet Propulsion Laboratory, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Lai, R [Northrop Grumman Corporation, Redondo Beach, CA 90278 (United States); Ruf, C [1533 Space Research Building, The University of Michigan, Ann Arbor, MI 48109-2143 (United States); Wollack, E, E-mail: charles.lawrence@jpl.nasa.go [NASA/GSFC, Code 665, Observational Cosmology Laboratory, Greenbelt, MD 20771 (United States)

    2009-03-01

    Coherent systems offer significant advantages in simplicity, testability, control of systematics, and cost. Although quantum noise sets the fundamental limit to their performance at high frequencies, recent breakthroughs suggest that near-quantum-limited noise up to 150 or even 200 GHz could be realized within a few years. If the demands of component separation can be met with frequencies below 200 GHz, coherent systems will be strong competitors for a space CMB polarization mission. The rapid development of digital correlator capability now makes space interferometers with many hundreds of elements possible. Given the advantages of coherent interferometers in suppressing systematic effects, such systems deserve serious study.

  18. Using Digital Cameras to Detect Warning Signs of Volcanic Eruptions

    Science.gov (United States)

    Girona, T.; Huber, C.; Trinh, K. T.; Protti, M.; Pacheco, J. F.

    2017-12-01

    Monitoring volcanic outgassing is fundamental to improve the forecasting of volcanic eruptions. Recent efforts have led to the advent of new methods to measure the concentration and flux of volcanic gases with unprecedented temporal resolution, thus allowing us to obtain reliable high-frequency (up to 1 Hz) time series of outgassing activity. These high-frequency methods have shown that volcanic outgassing can be periodic sometimes (with periodicities ranging from 101 s to 103 s), although it remains unknown whether the spectral features of outgassing reflect the processes that ultimately trigger volcanic unrest and eruptions. In this study, we explore the evolution of the spectral content of the outgassing activity of Turrialba volcano (Costa Rica) using digital images (with digital brightness as a proxy for the emissions of water vapor [Girona et al., 2015]). Images were taken at 1 km distance with 1 Hz sampling rate, and the time period analyzed (from April 2016 to April 2017) is characterized by episodes of quiescent outgassing, ash explosions, and sporadic eruptions of ballistics. Our preliminary results show that: 1) quiescent states of Turrialba volcano are characterized by outgassing frequency spectra with fractal distribution; 2) superimposed onto the fractal frequency spectra, well-defined pulses with period around 100 s emerge hours to days before some of the eruptions of ballistics. An important conclusion of this study is that digital cameras can be potentially used in real-time volcano monitoring to detect warning signs of eruptions, as well as to better understand subsurface processes and track the changing conditions below volcanic craters. Our ongoing study also explores the correlation between the evolution of the spectral content of outgassing, infrasound data, and shallow seismicity. Girona, T., F. Costa, B. Taisne, B. Aggangan, and S. Ildefonso (2015), Fractal degassing from Erebus and Mayon volcanoes revealed by a new method to monitor H2O

  19. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sharma, Madhurima; Sandhu, Manavjit Singh; Gorsi, Ujjwal; Gupta, Dheeraj; Khandelwal, Niranjan

    2015-01-01

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  20. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  1. Effect of image quality on calcification detection in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M.; Wallis, Matthew G.; Chakraborty, Dev P.; Dance, David R.; Bosmans, Hilde; Young, Kenneth C. [National Co-ordinating Centre for the Physics of Mammography, Royal Surrey County Hospital NHS Foundation Trust, Guildford GU2 7XX, United Kingdom and Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); Jarvis Breast Screening and Diagnostic Centre, Guildford GU1 1LJ (United Kingdom); Department of Radiology, St. George' s Healthcare NHS Trust, Tooting, London SW17 0QT (United Kingdom); Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge CB2 0QQ, United Kingdom and NIHR Cambridge Biomedical Research Centre, Cambridge CB2 0QQ (United Kingdom); Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania 15210 (United States); National Co-ordinating Centre for the Physics of Mammography, Royal Surrey County Hospital NHS Foundation Trust, Guildford GU2 7XX, United Kingdom and Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium); National Co-ordinating Centre for the Physics of Mammography, Royal Surrey County Hospital NHS Foundation Trust, Guildford GU2 7XX, United Kingdom and Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2012-06-15

    Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC

  2. A dedicated torsion balance to detect neutrinos by coherent scattering on high Debye temperature monocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Cruceru, I; Nicolescu, G [National Institute of Research and Development for Physics and Nuclear Engineering ' Horia - Hulubei' , PO Box MG - 6, 077125 Magurele (Romania); Duliu, O G [University of Bucharest, Department of Atomic and Nuclear Physics, PO Box MG-II, 077125 Magurele (Romania)

    2008-11-01

    Coherent scattering of neutrinos on high Debye temperature monocrystals represent an alternative to detect solar as well as other high flux neutrino sources such as nuclear reactors or nuclear tests. Therefore, the possibility of detecting neutrinos by using sapphire monocrystals is presented and analyzed. Preliminary evaluations showed that 1 MeV neutrinos with a fluency density of 10{sup 12} cm{sup -1} s{sup -1} could interact with a 100 g sapphire monocrystal with a force of about 10{sup -6} dyne, value measurable with a high sensitivity torsion balance. For this reason a torsion balance provided with 1 m length molybdenum or tungsten wire and an optical autocollimator able to measure small rotation angles of about 0.1 seconds of arc was designed, constructed and now is under preliminary tests. Both theoretical and practical implications of such kind of detector are presented and discussed.

  3. Fiber-optic polarization diversity detection for rotary probe optical coherence tomography.

    Science.gov (United States)

    Lee, Anthony M D; Pahlevaninezhad, Hamid; Yang, Victor X D; Lam, Stephen; MacAulay, Calum; Lane, Pierre

    2014-06-15

    We report a polarization diversity detection scheme for optical coherence tomography with a new, custom, miniaturized fiber coupler with single mode (SM) fiber inputs and polarization maintaining (PM) fiber outputs. The SM fiber inputs obviate matching the optical lengths of the X and Y OCT polarization channels prior to interference and the PM fiber outputs ensure defined X and Y axes after interference. Advantages for this scheme include easier alignment, lower cost, and easier miniaturization compared to designs with free-space bulk optical components. We demonstrate the utility of the detection system to mitigate the effects of rapidly changing polarization states when imaging with rotating fiber optic probes in Intralipid suspension and during in vivo imaging of human airways.

  4. Fiber-Based Polarization Diversity Detection for Polarization-Sensitive Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Hamid Pahlevaninezhad

    2014-09-01

    Full Text Available We present a new fiber-based polarization diversity detection (PDD scheme for polarization sensitive optical coherence tomography (PSOCT. This implementation uses a new custom miniaturized polarization-maintaining fiber coupler with single mode (SM fiber inputs and polarization maintaining (PM fiber outputs. The SM fiber inputs obviate matching the optical lengths of the two orthogonal OCT polarization channels prior to interference while the PM fiber outputs ensure defined orthogonal axes after interference. Advantages of this detection scheme over those with bulk optics PDD include lower cost, easier miniaturization, and more relaxed alignment and handling issues. We incorporate this PDD scheme into a galvanometer-scanned OCT system to demonstrate system calibration and PSOCT imaging of an achromatic quarter-wave plate, fingernail in vivo, and chicken breast, salmon, cow leg, and basa fish muscle samples ex vivo.

  5. Detection of Moving Targets Based on Doppler Spectrum Analysis Technique for Passive Coherent Radar

    Directory of Open Access Journals (Sweden)

    Zhao Yao-dong

    2013-06-01

    Full Text Available A novel method of moving targets detection taking Doppler spectrum analysis technique for Passive Coherent Radar (PCR is provided. After dividing the receiving signals into segments as pulse series, it utilizes the technique of pulse compress and Doppler processing to detect and locate the targets. Based on the algorithm for Pulse-Doppler (PD radar, the equipollence between continuous and pulsed wave in match filtering is proved and details of this method are introduced. To compare it with the traditional method of Cross-Ambiguity Function (CAF calculation, the relationship and mathematical modes of them are analyzed, with some suggestions on parameters choosing. With little influence to the gain of targets, the method can greatly promote the processing efficiency. The validity of the proposed method is demonstrated by offline processing real collected data sets and simulation results.

  6. Digital Image Processing Technique for Breast Cancer Detection

    Science.gov (United States)

    Guzmán-Cabrera, R.; Guzmán-Sepúlveda, J. R.; Torres-Cisneros, M.; May-Arrioja, D. A.; Ruiz-Pinales, J.; Ibarra-Manzano, O. G.; Aviña-Cervantes, G.; Parada, A. González

    2013-09-01

    Breast cancer is the most common cause of death in women and the second leading cause of cancer deaths worldwide. Primary prevention in the early stages of the disease becomes complex as the causes remain almost unknown. However, some typical signatures of this disease, such as masses and microcalcifications appearing on mammograms, can be used to improve early diagnostic techniques, which is critical for women’s quality of life. X-ray mammography is the main test used for screening and early diagnosis, and its analysis and processing are the keys to improving breast cancer prognosis. As masses and benign glandular tissue typically appear with low contrast and often very blurred, several computer-aided diagnosis schemes have been developed to support radiologists and internists in their diagnosis. In this article, an approach is proposed to effectively analyze digital mammograms based on texture segmentation for the detection of early stage tumors. The proposed algorithm was tested over several images taken from the digital database for screening mammography for cancer research and diagnosis, and it was found to be absolutely suitable to distinguish masses and microcalcifications from the background tissue using morphological operators and then extract them through machine learning techniques and a clustering algorithm for intensity-based segmentation.

  7. Detection of oral early cancerous lesion by using polarization-sensitive optical coherence tomography: mice model

    Science.gov (United States)

    Lee, Hong-Yi; Chen, Ping-Hsien; Lee, Tzu-Han; Chang, Kuo-Wei; Kuo, Wen-Chuan

    2018-02-01

    Oral cancer is the 11th most common cancer worldwide, especially in a male adult. The median age of death in oral cancer was 55 years, 10-20 years earlier than other cancers. Presently, oral cancer is often found in late stage, because the lesion is often flat in early stage and is difficult to diagnose under traditional white light imaging. The only definitive method for determining cancer is an invasive biopsy and then using histology examination. How to detect precancerous lesions or early malignant lesions is an important issue for improving prognosis of oral cancer. Optical coherence tomography (OCT) is a new optical tool for diagnosing early malignant lesions in the skin or gastrointestinal tract recently. Here we report a new method for detecting precancerous or early malignant oral lesions by using swept source polarization-sensitive optical coherence tomography (PS-OCT) with center-wavelength 1310 nm, bandwidth 110 nm and 100 kHz swept rate. We used all single-mode fiber design to detect the change of birefringence information in the epithelium structure. This system has an advantage that enables measurement of backscattered intensity and birefringence simultaneously with only one A-scan per transverse location. In preliminary result, we computed the slope of the every A-scan signal in tissue part using a linear-curve fitting in backscattered intensity and birefringence on the enface. In this research, we used an oral cancer mice model for observing the change of structure and birefringence properties in different stages of oral cancer mice. We presented the parametric enface imaging that can detect the early oral malignant lesions.

  8. Automated Meteor Detection by All-Sky Digital Camera Systems

    Science.gov (United States)

    Suk, Tomáš; Šimberová, Stanislava

    2017-12-01

    We have developed a set of methods to detect meteor light traces captured by all-sky CCD cameras. Operating at small automatic observatories (stations), these cameras create a network spread over a large territory. Image data coming from these stations are merged in one central node. Since a vast amount of data is collected by the stations in a single night, robotic storage and analysis are essential to processing. The proposed methodology is adapted to data from a network of automatic stations equipped with digital fish-eye cameras and includes data capturing, preparation, pre-processing, analysis, and finally recognition of objects in time sequences. In our experiments we utilized real observed data from two stations.

  9. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  10. Digital micromirror devices in Raman trace detection of explosives

    Science.gov (United States)

    Glimtoft, Martin; Svanqvist, Mattias; Ågren, Matilda; Nordberg, Markus; Östmark, Henric

    2016-05-01

    Imaging Raman spectroscopy based on tunable filters is an established technique for detecting single explosives particles at stand-off distances. However, large light losses are inherent in the design due to sequential imaging at different wavelengths, leading to effective transmission often well below 1 %. The use of digital micromirror devices (DMD) and compressive sensing (CS) in imaging Raman explosives trace detection can improve light throughput and add significant flexibility compared to existing systems. DMDs are based on mature microelectronics technology, and are compact, scalable, and can be customized for specific tasks, including new functions not available with current technologies. This paper has been focusing on investigating how a DMD can be used when applying CS-based imaging Raman spectroscopy on stand-off explosives trace detection, and evaluating the performance in terms of light throughput, image reconstruction ability and potential detection limits. This type of setup also gives the possibility to combine imaging Raman with non-spatially resolved fluorescence suppression techniques, such as Kerr gating. The system used consists of a 2nd harmonics Nd:YAG laser for sample excitation, collection optics, DMD, CMOScamera and a spectrometer with ICCD camera for signal gating and detection. Initial results for compressive sensing imaging Raman shows a stable reconstruction procedure even at low signals and in presence of interfering background signal. It is also shown to give increased effective light transmission without sacrificing molecular specificity or area coverage compared to filter based imaging Raman. At the same time it adds flexibility so the setup can be customized for new functionality.

  11. Rapid-scan Fourier-transform coherent anti-Stokes Raman scattering spectroscopy with heterodyne detection.

    Science.gov (United States)

    Hiramatsu, Kotaro; Luo, Yizhi; Ideguchi, Takuro; Goda, Keisuke

    2017-11-01

    High-speed Raman spectroscopy has become increasingly important for analyzing chemical dynamics in real time. To address the need, rapid-scan Fourier-transform coherent anti-Stokes Raman scattering (FT-CARS) spectroscopy has been developed to realize broadband CARS measurements at a scan rate of more than 20,000 scans/s. However, the detection sensitivity of FT-CARS spectroscopy is inherently low due to the limited number of photons detected during each scan. In this Letter, we show our experimental demonstration of enhanced sensitivity in rapid-scan FT-CARS spectroscopy by heterodyne detection. Specifically, we implemented heterodyne detection by superposing the CARS electric field with an external local oscillator (LO) for their interference. The CARS signal was amplified by simply increasing the power of the LO without the need for increasing the incident power onto the sample. Consequently, we achieved enhancement in signal intensity and the signal-to-noise ratio by factors of 39 and 5, respectively, compared to FT-CARS spectroscopy with homodyne detection. The sensitivity-improved rapid-scan FT-CARS spectroscopy is expected to enable the sensitive real-time observation of chemical dynamics in a broad range of settings, such as combustion engines and live biological cells.

  12. Automated Fovea Detection in Spectral Domain Optical Coherence Tomography Scans of Exudative Macular Disease

    Directory of Open Access Journals (Sweden)

    Jing Wu

    2016-01-01

    Full Text Available In macular spectral domain optical coherence tomography (SD-OCT volumes, detection of the foveal center is required for accurate and reproducible follow-up studies, structure function correlation, and measurement grid positioning. However, disease can cause severe obscuring or deformation of the fovea, thus presenting a major challenge in automated detection. We propose a fully automated fovea detection algorithm to extract the fovea position in SD-OCT volumes of eyes with exudative maculopathy. The fovea is classified into 3 main appearances to both specify the detection algorithm used and reduce computational complexity. Based on foveal type classification, the fovea position is computed based on retinal nerve fiber layer thickness. Mean absolute distance between system and clinical expert annotated fovea positions from a dataset comprised of 240 SD-OCT volumes was 162.3 µm in cystoid macular edema and 262 µm in nAMD. The presented method has cross-vendor functionality, while demonstrating accurate and reliable performance close to typical expert interobserver agreement. The automatically detected fovea positions may be used as landmarks for intra- and cross-patient registration and to create a joint reference frame for extraction of spatiotemporal features in “big data.” Furthermore, reliable analyses of retinal thickness, as well as retinal structure function correlation, may be facilitated.

  13. Effect of image quality on calcification detection in digital mammography.

    Science.gov (United States)

    Warren, Lucy M; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M; Wallis, Matthew G; Chakraborty, Dev P; Dance, David R; Bosmans, Hilde; Young, Kenneth C

    2012-06-01

    This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from

  14. Effect of image quality on calcification detection in digital mammography

    International Nuclear Information System (INIS)

    Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M.; Wallis, Matthew G.; Chakraborty, Dev P.; Dance, David R.; Bosmans, Hilde; Young, Kenneth C.

    2012-01-01

    Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC

  15. Testing continuous earthquake detection and location in Alentejo (South Portugal) by waveform coherency analysis

    Science.gov (United States)

    Matos, Catarina; Grigoli, Francesco; Cesca, Simone; Custódio, Susana

    2015-04-01

    In the last decade a permanent seismic network of 30 broadband stations, complemented by dense temporary deployments, covered Portugal. This extraordinary network coverage enables now the computation of a high-resolution image of the seismicity of Portugal, which in turn will shed light on the seismotectonics of Portugal. The large data volumes available cannot be analyzed by traditional time-consuming manual location procedures. In this presentation we show first results on the automatic detection and location of earthquakes occurred in a selected region in the south of Portugal Our main goal is to implement an automatic earthquake detection and location routine in order to have a tool to quickly process large data sets, while at the same time detecting low magnitude earthquakes (i.e., lowering the detection threshold). We present a modified version of the automatic seismic event location by waveform coherency analysis developed by Grigoli et al. (2013, 2014), designed to perform earthquake detections and locations in continuous data. The event detection is performed by continuously computing the short-term-average/long-term-average of two different characteristic functions (CFs). For the P phases we used a CF based on the vertical energy trace, while for S phases we used a CF based on the maximum eigenvalue of the instantaneous covariance matrix (Vidale 1991). Seismic event detection and location is obtained by performing waveform coherence analysis scanning different hypocentral coordinates. We apply this technique to earthquakes in the Alentejo region (South Portugal), taking advantage from a small aperture seismic network installed in the south of Portugal for two years (2010 - 2011) during the DOCTAR experiment. In addition to the good network coverage, the Alentejo region was chosen for its simple tectonic setting and also because the relationship between seismicity, tectonics and local lithospheric structure is intriguing and still poorly understood. Inside

  16. Breast Cancer Detection with Gabor Features from Digital Mammograms

    Directory of Open Access Journals (Sweden)

    Yufeng Zheng

    2010-01-01

    Full Text Available A new breast cancer detection algorithm, named the “Gabor Cancer Detection” (GCD algorithm, utilizing Gabor features is proposed. Three major steps are involved in the GCD algorithm, preprocessing, segmentation (generating alarm segments, and classification (reducing false alarms. In preprocessing, a digital mammogram is down-sampled, quantized, denoised and enhanced. Nonlinear diffusion is used for noise suppression. In segmentation, a band-pass filter is formed by rotating a 1-D Gaussian filter (off center in frequency space, termed as “Circular Gaussian Filter” (CGF. A CGF can be uniquely characterized by specifying a central frequency and a frequency band. A mass or calcification is a space-occupying lesion and usually appears as a bright region on a mammogram. The alarm segments (suspicious to be masses/calcifications can be extracted out using a threshold that is adaptively decided upon the histogram analysis of the CGF-filtered mammogram. In classification, a Gabor filter bank is formed with five bands by four orientations (horizontal, vertical, 45 and 135 degree in Fourier frequency domain. For each mammographic image, twenty Gabor-filtered images are produced. A set of edge histogram descriptors (EHD are then extracted from 20 Gabor images for classification. An EHD signature is computed with four orientations of Gabor images along each band and five EHD signatures are then joined together to form an EHD feature vector of 20 dimensions. With the EHD features, the fuzzy C-means clustering technique and k-nearest neighbor (KNN classifier are used to reduce the number of false alarms. The experimental results tested on the DDSM database (University of South Florida show the promises of GCD algorithm in breast cancer detection, which achieved TP (true positive rate = 90% at FPI (false positives per image = 1.21 in mass detection; and TP = 93% at FPI = 1.19 in calcification detection.

  17. Detection of coherent X-ray transition radiation and its application to beam diagnostics

    International Nuclear Information System (INIS)

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.I.; Li Qiang; Moran, M.J.; Bergstrom, J.C.; Caplan, H.S.; Silzer, R.M.; Skopik, D.M.; Rothbart, G.B.

    1989-01-01

    We investigate the use of coherent X-ray transition radiation to measure the energy of ultra-relativistic charged particles. This can be used for beam diagnostics for both high-repetition-rate and single-pulse, high-current accelerators. The research also has possible applications for the detection and identification of these particles. By selecting foil thickness and spacing, it is possible to design radiators whose angle of emission varies radically over a range of charged particle energies. We have constructed three coherent radiators and tested them at two accelerators using electron beam energies ranging from 50 to 228 MeV. Soft X-ray emission (1-3 keV) was emitted in a circularly symmetrical annulus with half-angle divergence of 2.5-9.0 mrad. The angle of peak emission was found to increase with electron-beam energy, in contrast to the incoherent case for which the angle of emission varies inversely with electron-beam energy. (orig.)

  18. Coherent optical communication detection device based on modified balanced optical phase-locked loop

    Science.gov (United States)

    Zhang, Bo; Sun, Jianfeng; Xu, Mengmeng; Li, Guangyuan; Zhang, Guo; Lao, Chenzhe; He, Hongyu; Lu, Zhiyong

    2017-08-01

    In the field of satellite communication, space laser communication technology is famous for its high communication rate, good confidentiality, small size, low power consumption and so on. The design of coherent optical communication detection device based on modified balanced optical phase-locked loop (OPLL) is presented in the paper. It combined by local oscillator beam, modulator, voltage controlled oscillator, signal beam, optical filter, 180 degree hybrid, balanced detector, loop filter and signal receiver. Local oscillator beam and voltage controlled oscillator trace the phase variation of signal beam simultaneously. That taking the advantage of voltage controlled oscillator which responses sensitively and tunable local oscillator laser source with large tuning range can trace the phase variation of signal beam rapidly and achieve phase locking. The demand of the phase deviation is very low, and the system is easy to adjust. When the transmitter transmits the binary phase shift keying (BPSK) signal, the receiver can demodulate the baseband signal quickly, which has important significance for the free space coherent laser communication.

  19. Adaptive cancellation of geomagnetic background noise for magnetic anomaly detection using coherence

    International Nuclear Information System (INIS)

    Liu, Dunge; Xu, Xin; Huang, Chao; Zhu, Wanhua; Liu, Xiaojun; Fang, Guangyou; Yu, Gang

    2015-01-01

    Magnetic anomaly detection (MAD) is an effective method for the detection of ferromagnetic targets against background magnetic fields. Currently, the performance of MAD systems is mainly limited by the background geomagnetic noise. Several techniques have been developed to detect target signatures, such as the synchronous reference subtraction (SRS) method. In this paper, we propose an adaptive coherent noise suppression (ACNS) method. The proposed method is capable of evaluating and detecting weak anomaly signals buried in background geomagnetic noise. Tests with real-world recorded magnetic signals show that the ACNS method can excellently remove the background geomagnetic noise by about 21 dB or more in high background geomagnetic field environments. Additionally, as a general form of the SRS method, the ACNS method offers appreciable advantages over the existing algorithms. Compared to the SRS method, the ACNS algorithm can eliminate the false target signals and represents a noise suppressing capability improvement of 6.4 dB. The positive outcomes in terms of intelligibility make this method a potential candidate for application in MAD systems. (paper)

  20. Skin surface and sub-surface strain and deformation imaging using optical coherence tomography and digital image correlation

    Science.gov (United States)

    Hu, X.; Maiti, R.; Liu, X.; Gerhardt, L. C.; Lee, Z. S.; Byers, R.; Franklin, S. E.; Lewis, R.; Matcher, S. J.; Carré, M. J.

    2016-03-01

    Bio-mechanical properties of the human skin deformed by external forces at difference skin/material interfaces attract much attention in medical research. For instance, such properties are important design factors when one designs a healthcare device, i.e., the device might be applied directly at skin/device interfaces. In this paper, we investigated the bio-mechanical properties, i.e., surface strain, morphological changes of the skin layers, etc., of the human finger-pad and forearm skin as a function of applied pressure by utilizing two non-invasive techniques, i.e., optical coherence tomography (OCT) and digital image correlation (DIC). Skin deformation results of the human finger-pad and forearm skin were obtained while pressed against a transparent optical glass plate under the action of 0.5-24 N force and stretching naturally from 90° flexion to 180° full extension respectively. The obtained OCT images showed the deformation results beneath the skin surface, however, DIC images gave overall information of strain at the surface.

  1. Two-stage Keypoint Detection Scheme for Region Duplication Forgery Detection in Digital Images.

    Science.gov (United States)

    Emam, Mahmoud; Han, Qi; Zhang, Hongli

    2018-01-01

    In digital image forensics, copy-move or region duplication forgery detection became a vital research topic recently. Most of the existing keypoint-based forgery detection methods fail to detect the forgery in the smooth regions, rather than its sensitivity to geometric changes. To solve these problems and detect points which cover all the regions, we proposed two steps for keypoint detection. First, we employed the scale-invariant feature operator to detect the spatially distributed keypoints from the textured regions. Second, the keypoints from the missing regions are detected using Harris corner detector with nonmaximal suppression to evenly distribute the detected keypoints. To improve the matching performance, local feature points are described using Multi-support Region Order-based Gradient Histogram descriptor. Based on precision-recall rates and commonly tested dataset, comprehensive performance evaluation is performed. The results demonstrated that the proposed scheme has better detection and robustness against some geometric transformation attacks compared with state-of-the-art methods. © 2017 American Academy of Forensic Sciences.

  2. Off-axis low coherence digital holographic interferometry for quantitative phase imaging with an LED

    Science.gov (United States)

    Guo, Rongli; Wang, Fan; Hu, Xiaoying; Yang, Wenqian

    2017-11-01

    Off-axis digital holographic interferometry with the light source of a light emitting diode (LED) is presented and its application for quantitative phase imaging in a large range with low noise is demonstrated. The scheme is implemented in a grating based Mach-Zehnder interferometer. To achieve off-axis interferometry, firstly, the collimated beam emitted from an LED is diffracted into multiple orders by a grating and they are split into two copies by a beam splitter; secondly, in the object arm the zero order of one copy is filtered in the Fourier plane and is reshaped to illuminate the sample, while in the reference arm one of its first order of another copy is selected to serve as the reference beam, and then an off-axis hologram can be obtained at the image plane. The main advantage stemming from an LED illumination is its high spatial phase resolution, due to the subdued speckle effect. The off-axis geometry enables one-shot recording of the hologram in the millisecond scale. The utility of the proposed setup is illustrated with measurements of a resolution target and part of a wing of green-lacewing, and dynamic evaporation process of an ethanol film.

  3. Low-cost coherent receiver for long-reach optical access network using single-ended detection.

    Science.gov (United States)

    Zhang, Xuebing; Li, Zhaohui; Li, Jianping; Yu, Changyuan; Lau, Alan Pak Tao; Lu, Chao

    2014-09-15

    A low-cost coherent receiver using two 2×3 optical hybrids and single-ended detection is proposed for long-reach optical access network. This structure can detect the two polarization components of polarization division multiplexing (PDM) signals. Polarization de-multiplexing and signal-to-signal beat interference (SSBI) cancellation are realized by using only three photodiodes. Simulation results for 40 Gb/s PDM-OFDM transmissions indicate that the low-cost coherent receiver has 3.2 dB optical signal-to-noise ratio difference compared with the theoretical value.

  4. Electron Signal Detection for the Beam-Finder Wire of the Linac Coherent Light Source Undulator

    International Nuclear Information System (INIS)

    Wu, Juhao; Emma, P.; Field, R.C.; SLAC

    2006-01-01

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. The tight tolerances for positioning the electron beam close to the undulator axis calls for the introduction of Beam Finder Wire (BFW) device. A BFW device close to the upstream end of the undulator segment and a quadrupole close to the down stream end of the undulator segment will allow a beam-based undulator segment alignment. Based on the scattering of the electrons on the BFW, we can detect the electron signal in the main dump bends after the undulator to find the beam position. We propose to use a threshold Cherenkov counter for this purpose. According to the signal strength at such a Cherenkov counter, we then suggest choice of material and size for such a BFW device in the undulator

  5. Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography

    Science.gov (United States)

    Pan, Y. T.; Xie, T. Q.; Du, C. W.; Bastacky, S.; Meyers, S.; Zeidel, M. L.

    2003-12-01

    We report an experimental study of the possibility of enhancing early bladder cancer diagnosis with fluorescence-image-guided endoscopic optical coherence tomography (OCT). After the intravesical instillation of a 10% solution of 5-aminolevulinic acid, simultaneous fluorescence imaging (excitation of 380-420 nm, emission of 620-700 nm) and OCT are performed on rat bladders to identify the photochemical and morphological changes associated with uroepithelial tumorigenesis. The preliminary results of our ex vivo study reveal that both fluorescence and OCT can identify early uroepithelial cancers, and OCT can detect precancerous lesions (e.g., hyperplasia) that fluorescence may miss. This suggests that a cystoscope combining 5-aminolevulinic acid fluorescence and OCT imaging has the potential to enhance the efficiency and sensitivity of early bladder cancer diagnosis.

  6. Experimental Study on GFRP Surface Cracks Detection Using Truncated-Correlation Photothermal Coherence Tomography

    Science.gov (United States)

    Wang, Fei; Liu, Junyan; Mohummad, Oliullah; Wang, Yang

    2018-04-01

    In this paper, truncated-correlation photothermal coherence tomography (TC-PCT) was used as a nondestructive inspection technique to evaluate glass-fiber reinforced polymer (GFRP) composite surface cracks. Chirped-pulsed signal that combines linear frequency modulation and pulse excitation was proposed as an excitation signal to detect GFRP composite surface cracks. The basic principle of TC-PCT and extraction algorithm of the thermal wave signal feature was described. The comparison experiments between lock-in thermography, thermal wave radar imaging and chirped-pulsed photothermal radar for detecting GFRP artificial surface cracks were carried out. Experimental results illustrated that chirped-pulsed photothermal radar has the merits of high signal-to-noise ratio in detecting GFRP composite surface cracks. TC-PCT as a depth-resolved photothermal imaging modality was employed to enable three-dimensional visualization of GFRP composite surface cracks. The results showed that TC-PCT can effectively evaluate the cracks depth of GFRP composite.

  7. Robust 9-QAM digital recovery for spectrum shaped coherent QPSK signal

    DEFF Research Database (Denmark)

    Huang, Bo; Zhang, Junwen; Yu, Jianjun

    2013-01-01

    division multiplexing (NWDM). The final equalized signal is detected by maximum likelihood sequence decision (MLSD) for data bit-error-ratio (BER) measurement. Optical signal-to-noise ratio (OSNR) tolerance is improved by 0.5 dB at a BER of 1x10-3 compared to constant modulus algorithm (CMA) plus post......We propose 9-ary quadrature amplitude modulation (9-QAM) data recovery for polarization multiplexing-quadrature phase shift keying (PM-QPSK) signal in presence of strong filtering to approach Nyquist bandwidth. The decision-directed least radius distance (DD-LRD) algorithm for blind equalization...

  8. Optical Coherence Tomography Minimum Intensity as an Objective Measure for the Detection of Hydroxychloroquine Toxicity.

    Science.gov (United States)

    Allahdina, Ali M; Stetson, Paul F; Vitale, Susan; Wong, Wai T; Chew, Emily Y; Ferris, Fredrick L; Sieving, Paul A; Cukras, Catherine

    2018-04-01

    As optical coherence tomography (OCT) minimum intensity (MI) analysis provides a quantitative assessment of changes in the outer nuclear layer (ONL), we evaluated the ability of OCT-MI analysis to detect hydroxychloroquine toxicity. Fifty-seven predominantly female participants (91.2% female; mean age, 55.7 ± 10.4 years; mean time on hydroxychloroquine, 15.0 ± 7.5 years) were enrolled in a case-control study and categorized into affected (i.e., with toxicity, n = 19) and unaffected (n = 38) groups using objective multifocal electroretinographic (mfERG) criteria. Spectral-domain OCT scans of the macula were analyzed and OCT-MI values quantitated for each subfield of the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. A two-sample U-test and a cross-validation approach were used to assess the sensitivity and specificity of toxicity detection according to OCT-MI criteria. The medians of the OCT-MI values in all nine of the ETDRS subfields were significantly elevated in the affected group relative to the unaffected group (P < 0.005 for all comparisons), with the largest difference found for the inner inferior subfield (P < 0.0001). The receiver operating characteristic analysis of median MI values of the inner inferior subfields showed high sensitivity and high specificity in the detection of toxicity with area under the curve = 0.99. Retinal changes secondary to hydroxychloroquine toxicity result in increased OCT reflectivity in the ONL that can be detected and quantitated using OCT-MI analysis. Analysis of OCT-MI values demonstrates high sensitivity and specificity for detecting the presence of hydroxychloroquine toxicity in this cohort and may contribute additionally to current screening practices.

  9. Tailoring automatic exposure control toward constant detectability in digital mammography.

    Science.gov (United States)

    Salvagnini, Elena; Bosmans, Hilde; Struelens, Lara; Marshall, Nicholas W

    2015-07-01

    The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. The default "opdose" AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d'), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (Tt) in the European guidelines for the 0.1 mm diameter disc (i.e., Tt ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (Tt), calculated detectability (d'), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. The default opdose AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d' 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d'), respectively. Threshold gold thickness (0.1 mm diameter disc) for the default

  10. Tailoring automatic exposure control toward constant detectability in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Salvagnini, Elena, E-mail: elena.salvagnini@uzleuven.be [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Bosmans, Hilde [Department of Imaging and Pathology, Medical Physics and Quality Assessment, KUL, Herestraat 49, Leuven B-3000, Belgium and Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Struelens, Lara [SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Marshall, Nicholas W. [Department of Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium)

    2015-07-15

    Purpose: The automatic exposure control (AEC) modes of most full field digital mammography (FFDM) systems are set up to hold pixel value (PV) constant as breast thickness changes. This paper proposes an alternative AEC mode, set up to maintain some minimum detectability level, with the ultimate goal of improving object detectability at larger breast thicknesses. Methods: The default “OPDOSE” AEC mode of a Siemens MAMMOMAT Inspiration FFDM system was assessed using poly(methyl methacrylate) (PMMA) of thickness 20, 30, 40, 50, 60, and 70 mm to find the tube voltage and anode/filter combination programmed for each thickness; these beam quality settings were used for the modified AEC mode. Detectability index (d′), in terms of a non-prewhitened model observer with eye filter, was then calculated as a function of tube current-time product (mAs) for each thickness. A modified AEC could then be designed in which detectability never fell below some minimum setting for any thickness in the operating range. In this study, the value was chosen such that the system met the achievable threshold gold thickness (T{sub t}) in the European guidelines for the 0.1 mm diameter disc (i.e., T{sub t} ≤ 1.10 μm gold). The default and modified AEC modes were compared in terms of contrast-detail performance (T{sub t}), calculated detectability (d′), signal-difference-to-noise ratio (SDNR), and mean glandular dose (MGD). The influence of a structured background on object detectability for both AEC modes was examined using a CIRS BR3D phantom. Computer-based CDMAM reading was used for the homogeneous case, while the images with the BR3D background were scored by human observers. Results: The default OPDOSE AEC mode maintained PV constant as PMMA thickness increased, leading to a reduction in SDNR for the homogeneous background 39% and d′ 37% in going from 20 to 70 mm; introduction of the structured BR3D plate changed these figures to 22% (SDNR) and 6% (d′), respectively

  11. BUILDING DETECTION USING AERIAL IMAGES AND DIGITAL SURFACE MODELS

    Directory of Open Access Journals (Sweden)

    J. Mu

    2017-05-01

    Full Text Available In this paper a method for building detection in aerial images based on variational inference of logistic regression is proposed. It consists of three steps. In order to characterize the appearances of buildings in aerial images, an effective bag-of-Words (BoW method is applied for feature extraction in the first step. In the second step, a classifier of logistic regression is learned using these local features. The logistic regression can be trained using different methods. In this paper we adopt a fully Bayesian treatment for learning the classifier, which has a number of obvious advantages over other learning methods. Due to the presence of hyper prior in the probabilistic model of logistic regression, approximate inference methods have to be applied for prediction. In order to speed up the inference, a variational inference method based on mean field instead of stochastic approximation such as Markov Chain Monte Carlo is applied. After the prediction, a probabilistic map is obtained. In the third step, a fully connected conditional random field model is formulated and the probabilistic map is used as the data term in the model. A mean field inference is utilized in order to obtain a binary building mask. A benchmark data set consisting of aerial images and digital surfaced model (DSM released by ISPRS for 2D semantic labeling is used for performance evaluation. The results demonstrate the effectiveness of the proposed method.

  12. 3D computer-aided detection for digital breast tomosynthesis: Comparison with 2D computer-aided detection for digital mammography in the detection of calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Chu, A Jung; Cho, Nariya; Chang, Jung Min; Kim, Won Hwa; Lee, Su Hyun; Song, Sung Eun; Shin, Sung Ui; Moon, Woo Kyung [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-08-15

    To retrospectively evaluate the performance of 3D computer-aided detection (CAD) for digital breast tomosynthesis (DBT) in the detection of calcifications in comparison with 2D CAD for digital mammography (DM). Between 2012 and 2013, both 3D CAD and 2D CAD systems were retrospectively applied to the calcification data set including 69 calcifications (31 malignant calcifications and 38 benign calcifications) and the normal data set including 20 bilateral normal mammograms. Each data set consisted of paired DBT and DM images. Sensitivities for the detection of malignant calcifications were calculated from the calcification data set. False-positive mark rates were calculated from the normal data set. They were compared between the two systems. Sensitivities of 3D CAD [100% (31/31) at levels 2, 1, and 0] were same as those of the 2D CAD system [100% (31/31) at levels 2 and 1] (p = 1.0, respectively). The mean value of false-positive marks per view with 3D CAD was higher than that with 2D CAD at level 2 (0.52 marks ± 0.91 vs. 0.07 marks ± 0.26, p = 0.009). 3D CAD for DBT showed equivalent sensitivity, albeit with a higher false-positive mark rate, than 2D CAD for DM in the detection of calcifications.

  13. Coherent time-stretch transformation for real-time capture of wideband signals.

    Science.gov (United States)

    Buckley, Brandon W; Madni, Asad M; Jalali, Bahram

    2013-09-09

    Time stretch transformation of wideband waveforms boosts the performance of analog-to-digital converters and digital signal processors by slowing down analog electrical signals before digitization. The transform is based on dispersive Fourier transformation implemented in the optical domain. A coherent receiver would be ideal for capturing the time-stretched optical signal. Coherent receivers offer improved sensitivity, allow for digital cancellation of dispersion-induced impairments and optical nonlinearities, and enable decoding of phase-modulated optical data formats. Because time-stretch uses a chirped broadband (>1 THz) optical carrier, a new coherent detection technique is required. In this paper, we introduce and demonstrate coherent time stretch transformation; a technique that combines dispersive Fourier transform with optically broadband coherent detection.

  14. Reproducibility of computer-aided detection system in digital mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Cho, Nariya; Cha, Joo Hee; Chung, Hye Kyung; Lee, Sin Ho; Cho, Kyung Soo; Kim, Sun Mi; Moon, Woo Kyung

    2005-01-01

    To evaluate the reproducibility of the computer-aided detection (CAD) system for digital mammograms. We applied the CAD system (ImageChecker M1000-DM, version 3.1; R2 Technology) to full field digital mammograms. These mammograms were taken twice at an interval of 10-45 days (mean:25 days) for 34 preoperative patients (breast cancer n=27, benign disease n=7, age range:20-66 years, mean age:47.9 years). On the mammograms, lesions were visible in 19 patients and these were depicted as 15 masses and 12 calcification clusters. We analyzed the sensitivity, the false positive rate (FPR) and the reproducibility of the CAD marks. The broader sensitivities of the CAD system were 80% (12 of 15), 67%(10 of 15) for masses and those for calcification clusters were 100% (12 of 12). The strict sensitivities were 50% (15 of 30) and 50% (15 of 30) for masses and 92% (22 of 24) and 79% (19 of 24) for the clusters. The FPR for the masses was 0.21-0.22/image, the FPR for the clusters was 0.03-0.04/image and the total FPR was 0.24-0.26/image. Among 132 mammography images, the identical images regardless of the existence of CAD marks were 59% (78 of 132), and the identical images with CAD marks were 22% (15 of 69). The reproducibility of the CAD marks for the true positive mass was 67% (12 of 18) and 71% (17 of 24) for the true positive cluster. The reproducibility of CAD marks for the false positive mass was 8% (4 of 53), and the reproducibility of CAD marks for the false positive clusters was 14% (1 of 7). The reproducibility of the total mass marks was 23% (16 of 71), and the reproducibility of the total cluster marks was 58% (18 of 31). CAD system showed higher sensitivity and reproducibility of CAD marks for the calcification clusters which are related to breast cancer. Yet the overall reproducibility of CAD marks was low; therefore, the CAD system must be applied considering this limitation

  15. Using spectral-domain optical coherence tomography to detect optic neuropathy in patients with craniosynostosis.

    Science.gov (United States)

    Dagi, Linda R; Tiedemann, Laura M; Heidary, Gena; Robson, Caroline D; Hall, Amber M; Zurakowski, David

    2014-12-01

    Detecting and monitoring optic neuropathy in patients with craniosynostosis is a clinical challenge due to limited cooperation, and subjective measures of visual function. The purpose of this study was to appraise the correlation of peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral-domain ocular coherence tomography (SD-OCT) with indication of optic neuropathy based on fundus examination. The medical records of all patients with craniosynostosis presenting for ophthalmic evaluation during 2013 were retrospectively reviewed. The following data were abstracted from the record: diagnosis, historical evidence of elevated intracranial pressure, current ophthalmic evaluation and visual field results, and current peripapillary RNFL thickness. A total of 54 patients were included (mean age, 10.6 years [range, 2.4-33.8 years]). Thirteen (24%) had evidence of optic neuropathy based on current fundus examination. Of these, 10 (77%) demonstrated either peripapillary RNFL elevation and papilledema or depression with optic atrophy. Sensitivity for detecting optic atrophy was 88%; for papilledema, 60%; and for either form of optic neuropathy, 77%. Specificity was 94%, 90%, and 83%, respectively. Kappa agreement was substantial for optic atrophy (κ = 0.73) and moderate for papilledema (κ = 0.39) and for either form of optic neuropathy (κ = 0.54). Logistic regression indicated that peripapillary RNFL thickness was predictive of optic neuropathy (P optic neuropathy than visual field testing (likelihood ratio = 10.02; P = 0.002). Sensitivity and specificity of logMAR visual acuity in detecting optic neuropathy were 15% and 95%, respectively. Peripapillary RNFL thickness measured by SD-OCT provides adjunctive evidence for identifying optic neuropathy in patients with craniosynostosis and appears more sensitive at detecting optic atrophy than papilledema. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by

  16. POST-DISASTER DAMAGE ASSESSMENT THROUGH COHERENT CHANGE DETECTION ON SAR IMAGERY

    Directory of Open Access Journals (Sweden)

    L. Guida

    2018-04-01

    Full Text Available Damage assessment is a fundamental step to support emergency response and recovery activities in a post-earthquake scenario. In recent years, UAVs and satellite optical imagery was applied to assess major structural damages before technicians could reach the areas affected by the earthquake. However, bad weather conditions may harm the quality of these optical assessments, thus limiting the practical applicability of these techniques. In this paper, the application of Synthetic Aperture Radar (SAR imagery is investigated and a novel approach to SAR-based damage assessment is presented. Coherent Change Detection (CCD algorithms on multiple interferometrically pre-processed SAR images of the area affected by the seismic event are exploited to automatically detect potential damages to buildings and other physical structures. As a case study, the 2016 Central Italy earthquake involving the cities of Amatrice and Accumoli was selected. The main contribution of the research outlined above is the integration of a complex process, requiring the coordination of a variety of methods and tools, into a unitary framework, which allows end-to-end application of the approach from SAR data pre-processing to result visualization in a Geographic Information System (GIS. A prototype of this pipeline was implemented, and the outcomes of this methodology were validated through an extended comparison with traditional damage assessment maps, created through photo-interpretation of high resolution aerial imagery. The results indicate that the proposed methodology is able to perform damage detection with a good level of accuracy, as most of the detected points of change are concentrated around highly damaged buildings.

  17. Post-Disaster Damage Assessment Through Coherent Change Detection on SAR Imagery

    Science.gov (United States)

    Guida, L.; Boccardo, P.; Donevski, I.; Lo Schiavo, L.; Molinari, M. E.; Monti-Guarnieri, A.; Oxoli, D.; Brovelli, M. A.

    2018-04-01

    Damage assessment is a fundamental step to support emergency response and recovery activities in a post-earthquake scenario. In recent years, UAVs and satellite optical imagery was applied to assess major structural damages before technicians could reach the areas affected by the earthquake. However, bad weather conditions may harm the quality of these optical assessments, thus limiting the practical applicability of these techniques. In this paper, the application of Synthetic Aperture Radar (SAR) imagery is investigated and a novel approach to SAR-based damage assessment is presented. Coherent Change Detection (CCD) algorithms on multiple interferometrically pre-processed SAR images of the area affected by the seismic event are exploited to automatically detect potential damages to buildings and other physical structures. As a case study, the 2016 Central Italy earthquake involving the cities of Amatrice and Accumoli was selected. The main contribution of the research outlined above is the integration of a complex process, requiring the coordination of a variety of methods and tools, into a unitary framework, which allows end-to-end application of the approach from SAR data pre-processing to result visualization in a Geographic Information System (GIS). A prototype of this pipeline was implemented, and the outcomes of this methodology were validated through an extended comparison with traditional damage assessment maps, created through photo-interpretation of high resolution aerial imagery. The results indicate that the proposed methodology is able to perform damage detection with a good level of accuracy, as most of the detected points of change are concentrated around highly damaged buildings.

  18. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    Directory of Open Access Journals (Sweden)

    Megan B. Goodman

    2015-08-01

    Full Text Available Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT and fundus auto fluorescence (FAF images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ, referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B consisted of 53 patients on CQ for more than 5 years. A 200 × 200 macula thickness map, 5-line raster SD-OCT on a Carl Zeiss Meditec Cirrus HD-OCT and FAF images on a Carl Zeiss Meditec Visucam 500 were recorded for 223 eyes. Images were reviewed independently, and then those of Groups A and B compared. Results: There were no statistically significant differences between Groups A and B. The criteria included the internal limiting membrane and the retinal pigment epithelium (ILM-RPE thickness, interdigitation zone integrity (p = 0.891, df = 1, χ² = 0.1876, ellipsoid zone integrity (p = 0.095, df = 2, χ² = 4.699 and FAF image irregularities (p = 0.479, df = 1, χ²= 4995978. Conclusion: The inclusion of SD-OCT and FAF as objective tests into the prescribed screening guidelines does not appear to simplify the detection of subclinical injury in patients on chloroquine treatment.

  19. Analysis of detection limit to time-resolved coherent anti-Stokes Raman scattering nanoscopy

    International Nuclear Information System (INIS)

    Liu Wei; Liu Shuang-Long; Chen Dan-Ni; Niu Han-Ben

    2014-01-01

    In the implementation of CARS nanoscopy, signal strength decreases with focal volume size decreasing. A crucial problem that remains to be solved is whether the reduced signal generated in the suppressed focal volume can be detected. Here reported is a theoretical analysis of detection limit (DL) to time-resolved CARS (T-CARS) nanoscopy based on our proposed additional probe-beam-induced phonon depletion (APIPD) method for the low concentration samples. In order to acquire a detailed shot-noise limited signal-to-noise (SNR) and the involved parameters to evaluate DL, the T-CARS process is described with full quantum theory to estimate the extreme power density levels of the pump and Stokes beams determined by saturation behavior of coherent phonons, which are both actually on the order of ∼ 10 9 W/cm 2 . When the pump and Stokes intensities reach such values and the total intensity of the excitation beams arrives at a maximum tolerable by most biological samples in a certain suppressed focal volume (40-nm suppressed focal scale in APIPD method), the DL correspondingly varies with exposure time, for example, DL values are 10 3 and 10 2 when exposure times are 20 ms and 200 ms respectively. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  20. Development of angle-resolved low coherence interferometry for clinical detection of dysplasia

    Directory of Open Access Journals (Sweden)

    Yizheng Zhu

    2011-01-01

    Full Text Available This review covers the development of angle-resolved low coherence interferometry (a/LCI from initial development through clinical application. In the first applications, the approach used a time-domain interferometry scheme and was validated using animal models of carcinogenesis to assess the feasibility of detecting dysplasia in situ. Further development of the approach led to Fourier-domain interferometry schemes with higher throughput and endoscope-compatible probes to enable clinical application. These later implementations have been applied to clinical studies of dysplasia in Barrett′s esophagus tissues, a metaplastic tissue type that is associated with an increased risk of esophageal adenocarcinoma. As an alternative to systematic biopsy, the a/LCI approach offers high sensitivity and specificity for detecting dysplasia in these tissues while avoiding the need for tissue removal or exogenous contrast agents. Here, the various implementations of a/LCI are discussed and the results of the preliminary animal experiments and ex vivo human tissue studies are reviewed. A review of a recent in vivo clinical study is also presented.

  1. Fast detection of vascular plaque in optical coherence tomography images using a reduced feature set

    Science.gov (United States)

    Prakash, Ammu; Ocana Macias, Mariano; Hewko, Mark; Sowa, Michael; Sherif, Sherif

    2018-03-01

    Optical coherence tomography (OCT) images are capable of detecting vascular plaque by using the full set of 26 Haralick textural features and a standard K-means clustering algorithm. However, the use of the full set of 26 textural features is computationally expensive and may not be feasible for real time implementation. In this work, we identified a reduced set of 3 textural feature which characterizes vascular plaque and used a generalized Fuzzy C-means clustering algorithm. Our work involves three steps: 1) the reduction of a full set 26 textural feature to a reduced set of 3 textural features by using genetic algorithm (GA) optimization method 2) the implementation of an unsupervised generalized clustering algorithm (Fuzzy C-means) on the reduced feature space, and 3) the validation of our results using histology and actual photographic images of vascular plaque. Our results show an excellent match with histology and actual photographic images of vascular tissue. Therefore, our results could provide an efficient pre-clinical tool for the detection of vascular plaque in real time OCT imaging.

  2. Optical coherence tomography for the structural changes detection in aging skin

    Science.gov (United States)

    Cheng, Chih-Ming; Chang, Yu-Fen; Chiang, Hung-Chih; Chang, Chir-Weei

    2018-01-01

    Optical coherence tomography (OCT) technique is an extremely powerful tool to detect numerous ophthalmological disorders, such as retinal disorder, and can be applied on other fields. Thus, many OCT systems are developed. For assessment of the skin textures, a cross-sectional (B-scan) spectra domain OCT system is better than an en-face one. However, this kind of commercial OCT system is not available. We designed a brand-new probe of commercial OCT system for evaluating skin texture without destroying the original instrument and it can be restored in 5 minutes. This modification of OCT system retains the advantages of commercial instrument, such as reliable, stable, and safe. Furthermore, the structural changes in aging skin are easily obtained by means of our probe, including larger pores, thinning of the dermis, collagen volume loss, vessel atrophy and flattening of dermal-epidermal junction. We can use this OCT technique in the field of cosmetic medicine such as detecting the skin textures and skin care product effect followup.

  3. Detection and Diagnosis of Oral Neoplasia with an Optical Coherence Microscope

    National Research Council Canada - National Science Library

    Clark, Anne

    2003-01-01

    .... The technique combines the sub-cellular resolution of high numerical aperture (NA) confocal microscopy with the increased sensitivity and penetration depth of optical coherence tomography (OCT...

  4. A comparison of periapical radiographs and their digital images for the detection of dental caries

    International Nuclear Information System (INIS)

    Kang, Byung Cheol

    1994-01-01

    In summary, it has been demonstrated by this study that the detection rate of definite large proximal surface caries (C2) on the digital images was good and the detection rate of the first stage caries (C1) was somewhat inferior to film based images. It has been demonstrated by this study and others that the detection of proximal surface caries by present clinical methodologies is still poor. Every effort should be made to develop new means to improve digitizing process.

  5. Performance Analysis of Long-Reach Coherent Detection OFDM-PON Downstream Transmission Using m-QAM-Mapped OFDM Signal

    Science.gov (United States)

    Pandey, Gaurav; Goel, Aditya

    2017-12-01

    In this paper, orthogonal frequency division multiplexing (OFDM)-passive optical network (PON) downstream transmission is demonstrated over different lengths of fiber at remote node (RN) for different m-QAM (quadrature amplitude modulation)-mapped OFDM signal (m=4, 16, 32 and 64) transmission from the central office (CO) for different data rates (10, 20 30 and 40 Gbps) using coherent detection at the user end or optical network unit (ONU). Investigation is performed with different number of subcarriers (32, 64, 128, 512 and 1,024), back-to-back optical signal-to-noise ratio (OSNR) along with transmitted and received constellation diagrams for m-QAM-mapped coherent OFDM downstream transmission at different speeds over different transmission distances. Received optical power is calculated for different bit error rates (BERs) at different speeds using m-QAM-mapped coherent detection OFDM downstream transmission. No dispersion compensation is utilized in between the fiber span. Simulation results suggest the different lengths and data rates that can be used for different m-QAM-mapped coherent detection OFDM downstream transmission, and the proposed system may be implemented in next-generation high-speed PONs (NG-PONs).

  6. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    Science.gov (United States)

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  7. Detection of motion artifacts in optical coherence tomography using the fundus enhancement system

    International Nuclear Information System (INIS)

    Schaudig, U.; Skevas, C.; Scholz, F.

    2007-01-01

    Extensive artefacts due to major eye movements are detectable in optical coherence tomography images (OCT), but frequency and extent of small eye movements have not been studied. To investigate frequency and extent of irregularities in OCT imaging due to eye movements during the scanning process in OCT. A fundus enhancement system (FES) originally designed to improve retinal image quality in a conventional OCT device (Zeiss Stratus OCT) in order to integrate OCT images into fluorescence angiographies was used to record the scanning process and review OCT-scan acquisition in slow motion. A horizontal and a vertical single line scan of 5 mm length through the center of fixation were obtained in 40 eyes of 20 normal healthy subjects, all with a visual acuity of at least 20/20. Scans were investigated for loss of fixation and eye movements during the scanning process. Outcome measures were presence or absence of eye movements during the scanning process and mean deviation from the intended scan position, measured in millimeter. 7 of 20 patients showed no eye movements in both eyes. 4 of the remaining 13 patients showed eye movements only in one eye. In the eyes with detectable movements, the mean deviation from the intended scan position was 0.2 mm in the horizontal and 0.28 mm in the vertical scans. Fundus imaging in conventional systems can be enhanced to detect artifacts due to minimal eye movements during the scanning process. In this first series with normal healthy subjects, minimal eye movements were present in the over half of the investigations. Although the distances from the intended scan positions seem to be small in normal eyes, further investigations of the phenomenon are necessary. OCT is increasingly used as the primary tool for controlling therapy in macular diseases and the extent of motion artefacts is not known. (author) [de

  8. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  9. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    International Nuclear Information System (INIS)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52 mm 2 . The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  10. On the performance of joint iterative detection and decoding in coherent optical channels with laser frequency fluctuations

    Science.gov (United States)

    Castrillón, Mario A.; Morero, Damián A.; Agazzi, Oscar E.; Hueda, Mario R.

    2015-08-01

    The joint iterative detection and decoding (JIDD) technique has been proposed by Barbieri et al. (2007) with the objective of compensating the time-varying phase noise and constant frequency offset experienced in satellite communication systems. The application of JIDD to optical coherent receivers in the presence of laser frequency fluctuations has not been reported in prior literature. Laser frequency fluctuations are caused by mechanical vibrations, power supply noise, and other mechanisms. They significantly degrade the performance of the carrier phase estimator in high-speed intradyne coherent optical receivers. This work investigates the performance of the JIDD algorithm in multi-gigabit optical coherent receivers. We present simulation results of bit error rate (BER) for non-differential polarization division multiplexing (PDM)-16QAM modulation in a 200 Gb/s coherent optical system that includes an LDPC code with 20% overhead and net coding gain of 11.3 dB at BER = 10-15. Our study shows that JIDD with a pilot rate ⩽ 5 % compensates for both laser phase noise and laser frequency fluctuation. Furthermore, since JIDD is used with non-differential modulation formats, we find that gains in excess of 1 dB can be achieved over existing solutions based on an explicit carrier phase estimator with differential modulation. The impact of the fiber nonlinearities in dense wavelength division multiplexing (DWDM) systems is also investigated. Our results demonstrate that JIDD is an excellent candidate for application in next generation high-speed optical coherent receivers.

  11. Detection of chemical interfaces in coherent anti-Stokes Raman scattering microscopy: Dk-CARS. I. Axial interfaces.

    Science.gov (United States)

    Gachet, David; Rigneault, Hervé

    2011-12-01

    We develop a full vectorial theoretical investigation of the chemical interface detection in conventional coherent anti-Stokes Raman scattering (CARS) microscopy. In Part I, we focus on the detection of axial interfaces (i.e., parallel to the optical axis) following a recent experimental demonstration of the concept [Phys. Rev. Lett. 104, 213905 (2010)]. By revisiting the Young's double slit experiment, we show that background-free microscopy and spectroscopy is achievable through the angular analysis of the CARS far-field radiation pattern. This differential CARS in k space (Dk-CARS) technique is interesting for fast detection of interfaces between molecularly different media. It may be adapted to other coherent and resonant scattering processes.

  12. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

    Science.gov (United States)

    Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin

    2007-01-01

    To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard

  13. Experimental 2.5 Gbit/s QPSK WDM coherent phase modulated radio-over-fibre link with digital demodulation by a K-means algorithm

    DEFF Research Database (Denmark)

    Guerrero Gonzalez, Neil; Caballero Jambrina, Antonio; Amaya Fernández, Ferney Orlando

    2009-01-01

    Highest reported bit rate of 2.5 Gbit/s for optically phase modulated radio-over-fibre link employing coherent detection is demonstrated. Demodulation of 3·2.5 Gbit/s QPSK modulated WDM channels, is achieved after 79km of transmission through deployed fiber....

  14. Enhanced performance for differential detection in coherent Brillouin optical time-domain analysis sensors

    Science.gov (United States)

    Shao, Liyang; Zhang, Yunpeng; Li, Zonglei; Zhang, Zhiyong; Zou, Xihua; Luo, Bin; Pan, Wei; Yan, Lianshan

    2016-11-01

    Logarithmic detectors (LogDs) have been used in coherent Brillouin optical time-domain analysis (BOTDA) sensors to reduce the effect of phase fluctuation, demodulation complexities, and measurement time. However, because of the inherent properties of LogDs, a DC component at the level of hundreds of millivolts that prohibits high-gain signal amplification (SA) could be generated, resulting in unacceptable data acquisition (DAQ) inaccuracies and decoding errors in the process of prototype integration. By generating a reference light at a level similar to the probe light, differential detection can be applied to remove the DC component automatically using a differential amplifier before the DAQ process. Therefore, high-gain SA can be employed to reduce quantization errors. The signal-to-noise ratio of the weak Brillouin gain signal is improved from ˜11.5 to ˜21.8 dB. A BOTDA prototype is implemented based on the proposed scheme. The experimental results show that the measurement accuracy of the Brillouin frequency shift (BFS) is improved from ±1.9 to ±0.8 MHz at the end of a 40-km sensing fiber.

  15. Coherent scattering noise reduction method with wavelength diversity detection for holographic data storage system

    Science.gov (United States)

    Nakamura, Yusuke; Hoshizawa, Taku; Takashima, Yuzuru

    2017-09-01

    A new method, wavelength diversity detection (WDD), for improving signal quality is proposed and its effectiveness is numerically confirmed. We consider that WDD is especially effective for high-capacity systems having low hologram diffraction efficiencies. In such systems, the signal quality is primarily limited by coherent scattering noise; thus, effective improvement of the signal quality under a scattering-limited system is of great interest. WDD utilizes a new degree of freedom, the spectrum width, and scattering by molecules to improve the signal quality of the system. We found that WDD improves the quality by counterbalancing the degradation of the quality due to Bragg mismatch. With WDD, a higher-scattering-coefficient medium can improve the quality. The result provides an interesting insight into the requirements for material characteristics, especially for a large-M/# material. In general, a larger-M/# material contains more molecules; thus, the system is subject to more scattering, which actually improves the quality with WDD. We propose a pathway for a future holographic data storage system (HDSS) using WDD, which can record a larger amount of data than a conventional HDSS.

  16. Effect of fibrinogen on blood coagulation detected by optical coherence tomography

    International Nuclear Information System (INIS)

    Xu, Xiangqun; Teng, Xiangshuai

    2015-01-01

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d 1/e ) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d 1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L −1 ); and 2) native plasma with commercial Fbg added (0–8 g L −1 ). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)

  17. Fourier-domain angle-resolved low coherence interferometry for clinical detection of dysplasia

    Science.gov (United States)

    Terry, Neil G.; Zhu, Yizheng; Wax, Adam

    2010-02-01

    Improved methods for detecting dysplasia, or pre-cancerous growth are a current clinical need, particularly in the esophagus. The currently accepted method of random biopsy and histological analysis provides only a limited examination of tissue in question while being coupled with a long time delay for diagnosis. Light scattering spectroscopy, in contrast, allows for inspection of the cellular structure and organization of tissue in vivo. Fourier-domain angle-resolved low-coherence interferometry (a/LCI) is a novel light scattering spectroscopy technique that provides quantitative depth-resolved morphological measurements of the size and optical density of the examined cell nuclei, which are characteristic biomarkers of dysplasia. Previously, clinical viability of the a/LCI system was demonstrated through analysis of ex vivo human esophageal tissue in Barrett's esophagus patients using a portable a/LCI, as was the development of a clinical a/LCI system. Data indicating the feasibility of the technique in other organ sites (colon, oral cavity) will be presented. We present an adaptation of the a/LCI system that will be used to investigate the presence of dysplasia in vivo in Barrett's esophagus patients.

  18. Early detection of the incidence of malignancy in mammograms using digital image correlation

    International Nuclear Information System (INIS)

    Espitia, J.; Jacome, J.; Torres, C.

    2016-01-01

    The digital image correlation has proved an effective way for Pattern Recognition, this research to identify the using Findings digitally extracted from a mammographic image, which is the means used by more specialists to determine if a person is a candidate or not, a Suffer Breast Cancer. This shown that early detection of symptom logy 'carcinogenic' is the key . (Author)

  19. Noise equalization for detection of microcalcification clusters in direct digital mammogram images.

    NARCIS (Netherlands)

    McLoughlin, K.J.; Bones, P.J.; Karssemeijer, N.

    2004-01-01

    Equalizing image noise is shown to be an important step in the automatic detection of microcalcifications in digital mammography. This study extends a well established film-screen noise equalization scheme developed by Veldkamp et al. for application to full-field digital mammogram (FFDM) images. A

  20. X-ray Digital Linear Tomosynthesis Imaging for Artificial Pulmonary Nodule Detection

    Directory of Open Access Journals (Sweden)

    Tsutomu Gomi

    2011-01-01

    Full Text Available The purpose of this paper is to identify indications for volumetric X-ray digital linear tomosynthesis (DLT with single- and dual-energy subtraction techniques for artificial pulmonary nodule detection and compare X-ray DLT, X-ray digital radiography, and computed tomography.

  1. Deep learning classifier with optical coherence tomography images for early dental caries detection

    Science.gov (United States)

    Karimian, Nima; Salehi, Hassan S.; Mahdian, Mina; Alnajjar, Hisham; Tadinada, Aditya

    2018-02-01

    Dental caries is a microbial disease that results in localized dissolution of the mineral content of dental tissue. Despite considerable decline in the incidence of dental caries, it remains a major health problem in many societies. Early detection of incipient lesions at initial stages of demineralization can result in the implementation of non-surgical preventive approaches to reverse the demineralization process. In this paper, we present a novel approach combining deep convolutional neural networks (CNN) and optical coherence tomography (OCT) imaging modality for classification of human oral tissues to detect early dental caries. OCT images of oral tissues with various densities were input to a CNN classifier to determine variations in tissue densities resembling the demineralization process. The CNN automatically learns a hierarchy of increasingly complex features and a related classifier directly from training data sets. The initial CNN layer parameters were randomly selected. The training set is split into minibatches, with 10 OCT images per batch. Given a batch of training patches, the CNN employs two convolutional and pooling layers to extract features and then classify each patch based on the probabilities from the SoftMax classification layer (output-layer). Afterward, the CNN calculates the error between the classification result and the reference label, and then utilizes the backpropagation process to fine-tune all the layer parameters to minimize this error using batch gradient descent algorithm. We validated our proposed technique on ex-vivo OCT images of human oral tissues (enamel, cortical-bone, trabecular-bone, muscular-tissue, and fatty-tissue), which attested to effectiveness of our proposed method.

  2. Practical purification scheme for decohered coherent-state superpositions via partial homodyne detection

    International Nuclear Information System (INIS)

    Suzuki, Shigenari; Takeoka, Masahiro; Sasaki, Masahide; Andersen, Ulrik L.; Kannari, Fumihiko

    2006-01-01

    We present a simple protocol to purify a coherent-state superposition that has undergone a linear lossy channel. The scheme constitutes only a single beam splitter and a homodyne detector, and thus is experimentally feasible. In practice, a superposition of coherent states is transformed into a classical mixture of coherent states by linear loss, which is usually the dominant decoherence mechanism in optical systems. We also address the possibility of producing a larger amplitude superposition state from decohered states, and show that in most cases the decoherence of the states are amplified along with the amplitude

  3. A joint estimation detection of Glaucoma progression in 3D spectral domain optical coherence tomography optic nerve head images

    Science.gov (United States)

    Belghith, Akram; Bowd, Christopher; Weinreb, Robert N.; Zangwill, Linda M.

    2014-03-01

    Glaucoma is an ocular disease characterized by distinctive changes in the optic nerve head (ONH) and visual field. Glaucoma can strike without symptoms and causes blindness if it remains without treatment. Therefore, early disease detection is important so that treatment can be initiated and blindness prevented. In this context, important advances in technology for non-invasive imaging of the eye have been made providing quantitative tools to measure structural changes in ONH topography, an essential element for glaucoma detection and monitoring. 3D spectral domain optical coherence tomography (SD-OCT), an optical imaging technique, has been commonly used to discriminate glaucomatous from healthy subjects. In this paper, we present a new framework for detection of glaucoma progression using 3D SD-OCT images. In contrast to previous works that the retinal nerve fiber layer (RNFL) thickness measurement provided by commercially available spectral-domain optical coherence tomograph, we consider the whole 3D volume for change detection. To integrate a priori knowledge and in particular the spatial voxel dependency in the change detection map, we propose the use of the Markov Random Field to handle a such dependency. To accommodate the presence of false positive detection, the estimated change detection map is then used to classify a 3D SDOCT image into the "non-progressing" and "progressing" glaucoma classes, based on a fuzzy logic classifier. We compared the diagnostic performance of the proposed framework to existing methods of progression detection.

  4. Self-tuning digital Mössbauer detection system

    Science.gov (United States)

    Veiga, A.; Grunfeld, C. M.; Pasquevich, G. A.; Mendoza Zélis, P.; Martínez, N.; Sánchez, F. H.

    2014-01-01

    Long term gamma spectroscopy experiments involving single-channel analyzer equipment depend upon thermal stability of the detector and its associated high-voltage supply. Assuming constant discrimination levels, a drift in the detector gain impacts the output rate, producing an effect on the output spectrum. In some cases (e.g. single-energy resonant absorption experiments) data of interest can be completely lost. We present a digital self-adapting discrimination strategy that tracks emission line shifts using statistical measurements on a predefined region-of-interest of the spectrum. It is developed in the form of a synthesizable module that can be intercalated in the digital processing chain. It requires a moderate to small amount of digital resources and can be easily activated and deactivated.

  5. Demonstration of Key Elements of a Dual Phase Argon Detection System Suitable for Measurement of Coherent Neutrino-Nucleus Scattering

    International Nuclear Information System (INIS)

    Adam, B; Celeste, W; Christian, H; Wolfgang, S; Norman, M

    2007-01-01

    This feasibility study sought to demonstrate several necessary steps in a research program whose ultimate goal is to detect coherent scattering of reactor antineutrinos in dual-phase noble liquid detectors. By constructing and operating a Argon gas-phase drift and scintillation test-bed, the study confirmed important expectations about sensitivity of these detectors, and thereby met the goals set forth in our original proposal. This work has resulted in a successful Lab-Wide LDRD for design and deployment of a coherent scatter detector at a nuclear reactor, and strong interest by DOE Office of Science. In recent years, researchers at LLNL and elsewhere have converged on a design approach for a new generation of very low noise, low background particle detectors known as two-phase noble liquid/noble gas ionization detectors. This versatile class of detector can be used to detect coherent neutrino scattering-an as yet unmeasured prediction of the Standard Model of particle physics. Using the dual phase technology, our group would be the first to verify the existence of this process. Its (non)detection would (refute)validate central tenets of the Standard Model. The existence of this process is also important in astrophysics, where coherent neutrino scattering is assumed to play an important role in energy transport within nascent neutron stars. The potential scientific impact after discovery of coherent neutrino-nuclear scattering is large. This phenomenon is flavor-blind (equal cross-sections of interaction for all three neutrino types), raising the possibility that coherent scatter detectors could be used as total flux monitors in future neutrino oscillation experiments. Such a detector could also be used to measure the flavor-blind neutrino spectrum from the next nearby (d ∼ 10kpc) type Ia supernova explosion. The predicted number of events [integrated over explosion time] for a proposed dual-phase argon coherent neutrino scattering detector is 10000 nuclear

  6. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  7. Change Detection by Interferometric Coherence in Nasca Lines, Peru (1997-2004)

    Science.gov (United States)

    Ruescas, Ana B.; Delgado, J. Manuel; Costantini, Fabiano; Sarti, Francesco

    2010-03-01

    Two interferometric pairs of Synthetic Aperture Radar (SAR) images are used to generate coherence images of the Nasca Lines Pampa area. The first coherence image is based on a pair of ERS-2 SAR data from 1997 and 1999; the second one is computed from two ENVISAT-ASAR (Advanced SAR) images from 2003 and 2004. The main objective is to study the changes in the coherence values in different parts of the area. Several different decorrelation factors contributing to a loss of coherency in a radar pair can be distinguished, and these include the temporal change in the ground properties and nature between the two satellite passes. In order to do this discrimination and interpretation, some ancillary data can be used, such as optical data from the Advanced Land Observing Satellite (ALOS), and meteorological data from the Global Precipitation Climatology Center (GPCC).

  8. PMD compensation in multilevel coded-modulation schemes with coherent detection using BLAST algorithm and iterative polarization cancellation.

    Science.gov (United States)

    Djordjevic, Ivan B; Xu, Lei; Wang, Ting

    2008-09-15

    We present two PMD compensation schemes suitable for use in multilevel (M>or=2) block-coded modulation schemes with coherent detection. The first scheme is based on a BLAST-type polarization-interference cancellation scheme, and the second scheme is based on iterative polarization cancellation. Both schemes use the LDPC codes as channel codes. The proposed PMD compensations schemes are evaluated by employing coded-OFDM and coherent detection. When used in combination with girth-10 LDPC codes those schemes outperform polarization-time coding based OFDM by 1 dB at BER of 10(-9), and provide two times higher spectral efficiency. The proposed schemes perform comparable and are able to compensate even 1200 ps of differential group delay with negligible penalty.

  9. SAR COHERENCE CHANGE DETECTION OF URBAN AREAS AFFECTED BY DISASTERS USING SENTINEL-1 IMAGERY

    Directory of Open Access Journals (Sweden)

    P. Washaya

    2018-04-01

    Full Text Available The study focuses on two study areas: San Juan in Puerto Rico, which was affected by Hurricane Maria in September 2017, and Sarpol Zahab in Iran, which was one of the towns affected by an earthquake in November 2017. In our study, we generate coherence images, and classify them into areas of ‘change’ and ‘no-change’. A statistical analysis is made by converting the coherence results into point data, creating street blocks for the study areas and integrating the point data into the street blocks to calculate the standard deviation over the whole stack of images. Additionally, Landsat imagery is used to create land-use classes, convert them to polygons and integrate the polygon classes to the coherence maps to determine the average coherence loss per class for each disaster. Results show 65 % loss in coherence after the earthquake in Sarpol-e-Zahab and 75 % loss in Puerto Rico after the Hurricane. Land-use classes show coherence losses to below 0.5 for each disaster.

  10. SAR Coherence Change Detection of Urban Areas Affected by Disasters Using SENTINEL-1 Imagery

    Science.gov (United States)

    Washaya, P.; Balz, T.

    2018-04-01

    The study focuses on two study areas: San Juan in Puerto Rico, which was affected by Hurricane Maria in September 2017, and Sarpol Zahab in Iran, which was one of the towns affected by an earthquake in November 2017. In our study, we generate coherence images, and classify them into areas of `change' and `no-change'. A statistical analysis is made by converting the coherence results into point data, creating street blocks for the study areas and integrating the point data into the street blocks to calculate the standard deviation over the whole stack of images. Additionally, Landsat imagery is used to create land-use classes, convert them to polygons and integrate the polygon classes to the coherence maps to determine the average coherence loss per class for each disaster. Results show 65 % loss in coherence after the earthquake in Sarpol-e-Zahab and 75 % loss in Puerto Rico after the Hurricane. Land-use classes show coherence losses to below 0.5 for each disaster.

  11. Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

    Science.gov (United States)

    Oh, Jong-Hyun

    2009-01-01

    Purpose To compare the ability of scanning laser polarimetry with variable corneal compensation (GDx-VCC) and Stratus optical coherence tomography (OCT) to detect photographic retinal nerve fiber layer (RNFL) defects. Methods This retrospective cross-sectional study included 45 eyes of 45 consecutive glaucoma patients with RNFL defects in red-free fundus photographs. The superior and inferior temporal quadrants in each eye were included for data analysis separately. The location and presence of RNFL defects seen in red-free fundus photographs were compared with those seen in GDx-VCC deviation maps and OCT RNFL analysis maps for each quadrant. Results Of the 90 quadrants (45 eyes), 31 (34%) had no apparent RNFL defects, 29 (32%) had focal RNFL defects, and 30 (33%) had diffuse RNFL defects in red-free fundus photographs. The highest agreement between GDx-VCC and red-free photography was 73% when we defined GDx-VCC RNFL defects as a cluster of three or more color-coded squares (p<5%) along the traveling line of the retinal nerve fiber in the GDx-VCC deviation map (kappa value, 0.388; 95% confidence interval (CI), 0.195 to 0.582). The highest agreement between OCT and red-free photography was 85% (kappa value, 0.666; 95% CI, 0.506 to 0.825) when a value of 5% outside the normal limit for the OCT analysis map was used as a cut-off value for OCT RNFL defects. Conclusions According to the kappa values, the agreement between GDx-VCC deviation maps and red-free photography was poor, whereas the agreement between OCT analysis maps and red-free photography was good. PMID:19794943

  12. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy.

    Science.gov (United States)

    Virgili, Gianni; Menchini, Francesca; Casazza, Giovanni; Hogg, Ruth; Das, Radha R; Wang, Xue; Michelessi, Manuele

    2015-01-07

    Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO. To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO. We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings

  13. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...

  14. DETECTION OF MICROVASCULAR CHANGES IN EYES OF PATIENTS WITH DIABETES BUT NOT CLINICAL DIABETIC RETINOPATHY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    de Carlo, Talisa E; Chin, Adam T; Bonini Filho, Marco A; Adhi, Mehreen; Branchini, Lauren; Salz, David A; Baumal, Caroline R; Crawford, Courtney; Reichel, Elias; Witkin, Andre J; Duker, Jay S; Waheed, Nadia K

    2015-11-01

    To evaluate the ability of optical coherence tomography angiography to detect early microvascular changes in eyes of diabetic individuals without clinical retinopathy. Prospective observational study of 61 eyes of 39 patients with diabetes mellitus and 28 control eyes of 22 age-matched healthy subjects that received imaging using optical coherence tomography angiography between August 2014 and March 2015. Eyes with concomitant retinal, optic nerve, and vitreoretinal interface diseases and/or poor-quality images were excluded. Foveal avascular zone size and irregularity, vessel beading and tortuosity, capillary nonperfusion, and microaneurysm were evaluated. Foveal avascular zone size measured 0.348 mm² (0.1085-0.671) in diabetic eyes and 0.288 mm² (0.07-0.434) in control eyes (P = 0.04). Foveal avascular zone remodeling was seen more often in diabetic than control eyes (36% and 11%, respectively; P = 0.01). Capillary nonperfusion was noted in 21% of diabetic eyes and 4% of control eyes (P = 0.03). Microaneurysms and venous beading were noted in less than 10% of both diabetic and control eyes. Both diabetic and healthy control eyes demonstrated tortuous vessels in 21% and 25% of eyes, respectively. Optical coherence tomography angiography was able to image foveal microvascular changes that were not detected by clinical examination in diabetic eyes. Changes to the foveal avascular zone and capillary nonperfusion were more prevalent in diabetic eyes, whereas vessel tortuosity was observed with a similar frequency in normal and diabetic eyes. Optical coherence tomography angiography may be able to detect diabetic eyes at risk of developing retinopathy and to screen for diabetes quickly and noninvasively before the systemic diagnosis is made.

  15. A comparison between conventional radiography and digitized image accuracy in proximal caries detection

    Directory of Open Access Journals (Sweden)

    Pangnoosh M

    2003-08-01

    Full Text Available Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should"nalso be noted that the accuracy of the technique and work conditions affects the radiographs information"nconsiderably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate"ndifferent digitized radiographic techniques and to compare them with the conventional technique."nPurpose: The aim of this study was to compare the accuracy of conventional and digitized radiographic"nimages by three digitization techniques in proximal caries detection."nMaterial and Methods: In this research study, sixty extracted human canines, premolars and molars were"nmounted in blocks and imaged on E-Kodak film, similar to bitewing radiographs. Ten bitewing radiographs"nwere then scanned at 600 d.p.i with flat bed scanner and a digital camera, then digitized at 300 d.p.i with"nanother digital camera. The digitized images were displayed randomly on a high-resolution monitor. Six"nobservers assessed the caries status of 120 proximal surfaces by conventional and digitized images. The"nobserver's scores were compared with the results of the macroscopic examination. Reliability of each"ntechnique was calculated. Data were analyzed using chi-square and ANOVA tests."nResults: No significant differences were detected between different techniques in intact proximal surfaces and"nenamel caries diagnosis. However, digital techniques were more sensitive in dentin caries detection (P<0.05."nConclusions: When conventional film images are digitized, medium resolution (300 d.p.i seems to be"nsufficient. At this resolution the file size is decreased and there is no significant loss of the information"nnecessary for caries diagnosis.

  16. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  17. Digital stethoscopes compared to standard auscultation for detecting abnormal paediatric breath sounds.

    Science.gov (United States)

    Kevat, Ajay C; Kalirajah, Anaath; Roseby, Robert

    2017-07-01

    Our study aimed to objectively describe the audiological characteristics of wheeze and crackles in children by using digital stethoscope (DS) auscultation, as well as assess concordance between standard auscultation and two different DS devices in their ability to detect pathological breath sounds. Twenty children were auscultated by a paediatric consultant doctor and digitally recorded using the Littman™ 3200 Digital Electronic Stethoscope and a Clinicloud™ DS with smart device. Using spectrographic analysis, we found those with clinically described wheeze had prominent periodic waveform segments spanning expiration for a period of 0.03-1.2 s at frequencies of 100-1050 Hz, and occasionally spanning shorter inspiratory segments; paediatric crackles were brief discontinuous sounds with a distinguishing waveform. There was moderate concordance with respect to wheeze detection between digital and standard binaural stethoscopes, and 100% concordance for crackle detection. Importantly, DS devices were more sensitive than clinician auscultation in detecting wheeze in our study. Objective definition of audio characteristics of abnormal paediatric breath sounds was achieved using DS technology. We demonstrated superiority of our DS method compared to traditional auscultation for detection of wheeze. What is Known: • The audiological characteristics of abnormal breath sounds have been well-described in adult populations but not in children. • Inter-observer agreement for detection of pathological breath sounds using standard auscultation has been shown to be poor, but the clinical value of now easily available digital stethoscopes has not been sufficiently examined. What is New: • Digital stethoscopes can objectively define the nature of pathological breath sounds such as wheeze and crackles in children. • Paediatric wheeze was better detected by digital stethoscopes than by standard auscultation performed by an expert paediatric clinician.

  18. Coherent spectral amplitude coded label detection for DQPSK payload signals in packet-switched metropolitan area networks

    DEFF Research Database (Denmark)

    Osadchiy, Alexey Vladimirovich; Guerrero Gonzalez, Neil; Jensen, Jesper Bevensee

    2011-01-01

    We report on an experimental demonstration of a frequency swept local oscillator-based spectral amplitude coding (SAC) label detection for DQPSK signals after 40km of fiber transmission. Label detection was performed for a 10.7Gbaud DQPSK signal labeled with a SAC label composed of four......-frequency tones with 500MHz spectral separation. Successful label detection and recognition is achieved with the aid of digital signal processing that allows for substantial reduction of the complexity of the detection optical front-end....

  19. Real time 1.55 μm VCSEL-based coherent detection link

    DEFF Research Database (Denmark)

    Rodes Lopez, Roberto; Parekh, D.; Jensen, Jesper Bevensee

    2012-01-01

    This paper presents an experimental demonstration of VCSEL-based PON with simplified real-time coherent receiver at 2.5 Gbps. Receiver sensitivity of −37 dBm is achieved proving splitting ratio up to 2048 after 17 km fiber transmission.......This paper presents an experimental demonstration of VCSEL-based PON with simplified real-time coherent receiver at 2.5 Gbps. Receiver sensitivity of −37 dBm is achieved proving splitting ratio up to 2048 after 17 km fiber transmission....

  20. Retinopathy online challenge: automatic detection of microaneurysms in digital color fundus photographs.

    NARCIS (Netherlands)

    Niemeijer, M.; Ginneken, B. van; Cree, M.J.; Mizutani, A.; Quellec, G.; Sanchez, C.I.; Zhang, B.; Hornero, R.; Lamard, M.; Muramatsu, C.; Wu, X.; Cazuguel, G.; You, J.; Mayo, A.; Li, Q.; Hatanaka, Y.; Cochener, B.; Roux, C.; Karray, F.; Garcia, M.; Fujita, H.; Abramoff, M.D.

    2010-01-01

    The detection of microaneurysms in digital color fundus photographs is a critical first step in automated screening for diabetic retinopathy (DR), a common complication of diabetes. To accomplish this detection numerous methods have been published in the past but none of these was compared with each

  1. Electrochemical detection on electrowetting-on-dielectric digital microfluidic chip.

    Science.gov (United States)

    Karuwan, Chanpen; Sukthang, Kreeta; Wisitsoraat, Anurat; Phokharatkul, Ditsayut; Patthanasettakul, Viyapol; Wechsatol, Wishsanuruk; Tuantranont, Adisorn

    2011-06-15

    In this work, the use of three-electrode electrochemical sensing system with an electrowetting-on-dielectric (EWOD) digital microfluidic device is reported for quantitative analysis of iodide. T-junction EWOD mixer device was designed using arrays of 50-μm spaced square electrodes for mixing buffer reagent and analyte droplets. For fabrication of EWOD chips, 5-μm thick silver EWOD electrodes were formed on a glass substrate by means of sputtering and lift-off process. PDMS and Teflon thin films were then coated on the electrodes by spin coating to yield hydrophobic surface. An external three-electrode system consisting of Au working, Ag reference and Pt auxiliary wires were installed over EWOD electrodes at the end of T-junction mixer. In experiment, a few-microliter droplets of Tris buffer and iodide solutions were moved toward the mixing junction and transported toward electrochemical electrodes by EWOD process. A short processing time within seconds was achieved at EWOD applied voltage of 300V. The analyte droplets mixed with different concentrations were successfully analyzed by cyclic voltametry. Therefore, the combination of EWOD digital microfluidic and electrochemical sensing system has successfully been demonstrated for rapid chemical analysis with minimal reagent consumption. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Segmentation of the Breast Region in Digital Mammograms and Detection of Masses

    OpenAIRE

    Armen Sahakyan; Hakop Sarukhanyan

    2012-01-01

    The mammography is the most effective procedure for an early diagnosis of the breast cancer. Finding an accurate and efficient breast region segmentation technique still remains a challenging problem in digital mammography. In this paper we explore an automated technique for mammogram segmentation. The proposed algorithm uses morphological preprocessing algorithm in order to: remove digitization noises and separate background region from the breast profile region for further edge detection an...

  3. A localized in vivo detection method for lactate using zero quantum coherence techniques

    NARCIS (Netherlands)

    van Dijk, J. E.; Bosman, D. K.; Chamuleau, R. A.; Bovee, W. M.

    1991-01-01

    A method is described to selectively measure lactate in vivo using proton zero quantum coherence techniques. The signal from lipids is eliminated. A surface coil and additionally slice selective localization are used. The resulting spectra demonstrate the good performance of the method

  4. Derivation of a Monte Carlo method for modeling heterodyne detection in optical coherence tomography systems

    DEFF Research Database (Denmark)

    Tycho, Andreas; Jørgensen, Thomas Martini; Andersen, Peter E.

    2002-01-01

    A Monte Carlo (MC) method for modeling optical coherence tomography (OCT) measurements of a diffusely reflecting discontinuity emb edded in a scattering medium is presented. For the first time to the authors' knowledge it is shown analytically that the applicability of an MC approach to this opti...

  5. Novelty detection-based internal fingerprint segmentation in optical coherence tomography images

    CSIR Research Space (South Africa)

    Khutlang, Rethabile

    2017-08-01

    Full Text Available present an automatic segmentation of the papillary layer method, from images acquired using contact-less 3-D swept source optical coherence tomography (OCT). The papillary contour represents the internal fingerprint, which does not suffer from the external...

  6. Coherent laser radar with dual-frequency Doppler estimation and interferometric range detection

    NARCIS (Netherlands)

    Onori, D.; Scotti, F.; Laghezza, F.; Scaffardi, M.; Bogoni, A.

    2016-01-01

    The concept of a coherent interferometric dual frequency laser radar, that measures both the target range and velocity, is presented and experimentally demonstrated. The innovative architecture combines the dual frequency lidar concept, allowing a precise and robust Doppler estimation, with the

  7. Novelty detection-based internal fingerprint segmentation in optical coherence tomography images

    CSIR Research Space (South Africa)

    Khutlang, R

    2014-12-01

    Full Text Available present an automatic segmentation of the papillary layer method, in 3-D swept source optical coherence tomography (SS-OCT) images. The papillary contour represents the internal fingerprint, which does not suffer external skin problems. The slices composing...

  8. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    National Research Council Canada - National Science Library

    Singh, Swatee; Lo, Joseph

    2008-01-01

    The purpose of this study was to investigate feasibility of computer-aided detection of masses and calcification clusters in breast tomosynthesis images and obtain reliable estimates of sensitivity...

  9. Intravenous digital angiography for the detection of renovascular hypertension

    International Nuclear Information System (INIS)

    Dunnick, N.R.; Svetkey, L.; Braun, S.D.; Cohan, R.H.; Newman, G.E.; Himmelstein, S.I.; Klotman, P.E.

    1987-01-01

    In order to assess the accuracy of intravenous digital subtraction angiography (IV-DSA), the authors prospectively studied all patients referred for suspected renovascular hypertension with IV-DSA and conventional angiography. The IV-DSA study demonstrated renal artery stenosis in 25 patients. A significant main renal artery lesion was confirmed in 21 of these patients while four patients had either normal renal arteries or insignificant changes. The IV-DSA examination was considered negative for renal artery stenosis in 50 patients. This was confirmed in 49 patients, but one patient had a branch renal artery stenosis. The sensitivity of IV-DSA was 96% while the specificity was 93%. The negative predictive value was 98% and the positive predictive value 84%. IV-DSA provides good anatomic definition of the main renal arteries and is sufficiently sensitive to be used as a screening test for renovascular hypertension

  10. Waveform correlation and coherence of short-period seismic noise within Gauribidanur array with implications for event detection

    International Nuclear Information System (INIS)

    Bhadauria, Y.S.; Arora, S.K.

    1995-01-01

    In continuation with our effort to model the short-period micro seismic noise at the seismic array at Gauribidanur (GBA), we have examined in detail time-correlation and spectral coherence of the noise field within the array space. This has implications of maximum possible improvement in signal-to-noise ratio (SNR) relevant to event detection. The basis of this study is about a hundred representative wide-band noise samples collected from GBA throughout the year 1992. Both time-structured correlation as well as coherence of the noise waveforms are found to be practically independent of the inter element distances within the array, and they exhibit strong temporal and spectral stability. It turns out that the noise is largely incoherent at frequencies ranging upwards from 2 Hz; the coherency coefficient tends to increase in the lower frequency range attaining a maximum of 0.6 close to 0.5 Hz. While the maximum absolute cross-correlation also diminishes with increasing frequency, the zero-lag cross-correlation is found to be insensitive to frequency filtering regardless of the pass band. An extremely small value of -0.01 of the zero-lag correlation and a comparatively higher year-round average estimate at 0.15 of the maximum absolute time-lagged correlation yields an SNR improvement varying between a probable high of 4.1 and a low of 2.3 for the full 20-element array. 19 refs., 6 figs

  11. Conventional and digital radiographic methods in the detection of simulated external root resorptions: A comparative study

    Directory of Open Access Journals (Sweden)

    C J Sanjay

    2009-01-01

    Full Text Available Objective : To evaluate and compare the efficacy of conventional and digital radiographic methods in the detection of simulated external root resorption cavities and also to evaluate whether the detectability was influenced by resorption cavity sizes. Methods : Thirty-two selected teeth from human dentate mandibles were radiographed in orthoradial, mesioradial and distoradial aspect using conventional film (Insight Kodak F-speed; Eastman Kodak, Rochester, NY and a digital sensor (Trophy RVG advanced imaging system with 0.7mm and 1.0mm deep cavities prepared on their vestibular, mesial and distal surfaces at the cervical, middle and apical thirds. Three dental professionals, an endodontist, a radiologist and a general practitioner, evaluated the images twice with a one-week time interval. Results : No statistical significance was seen in the first observation for both conventional and digital radiographic methods in the detection of simulated external root resorptions and for small and medium cavities but statistical difference was noted in the second observation (P< 0.001 for both the methods. Conclusion : Considering the methodology and the overall results, conventional radiographic method (F-speed performed slightly better than the digital radiographic method in the detection of simulated radiographic method but better consistency was seen with the digital system. Overall size of the resorption cavity had no influence on the performance of both methods and suggests that initial external root resorption lesion is not well-appreciated with both the methods as compared to the advanced lesion.

  12. Detection of proximal caries using digital radiographic systems with different resolutions.

    Science.gov (United States)

    Nikneshan, Sima; Abbas, Fatemeh Mashhadi; Sabbagh, Sedigheh

    2015-01-01

    Dental radiography is an important tool for detection of caries and digital radiography is the latest advancement in this regard. Spatial resolution is a characteristic of digital receptors used for describing the quality of images. This study was aimed to compare the diagnostic accuracy of two digital radiographic systems with three different resolutions for detection of noncavitated proximal caries. Diagnostic accuracy. Seventy premolar teeth were mounted in 14 gypsum blocks. Digora; Optime and RVG Access were used for obtaining digital radiographs. Six observers evaluated the proximal surfaces in radiographs for each resolution in order to determine the depth of caries based on a 4-point scale. The teeth were then histologically sectioned, and the results of histologic analysis were considered as the gold standard. Data were entered using SPSS version 18 software and the Kruskal-Wallis test was used for data analysis. P detection of proximal caries (P > 0.05). RVG access system had the highest specificity (87.7%) and Digora; Optime at high resolution had the lowest specificity (84.2%). Furthermore, Digora; Optime had higher sensitivity for detection of caries exceeding outer half of enamel. Judgment of oral radiologists for detection of the depth of caries had higher reliability than that of restorative dentistry specialists. The three resolutions of Digora; Optime and RVG access had similar accuracy in detection of noncavitated proximal caries.

  13. Computerized detection of lung nodules in digital chest radiographs

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; MacMahon, H.

    1987-01-01

    Detection of cancerous lung nodules in chest radiographs is one of the more important tasks performed by a radiologist. In addition, the ''miss rate'' associated with the radiographic detection of lung nodules is approximately 30%. A computerized scheme that alerts the radiologist to possible locations of lung nodules should allow this number of false-negative diagnoses to be reduced. The authors are developing a computer-aided nodule detection scheme based on a difference image approach. They attempt to eliminate the camouflaging background structure of the normal lung anatomy by creating, from a single-projection chest image, two images: one in which the signal-to-noise ratio (SNR) of the nodule is maximized and another in which that SNR is suppressed while the processed background remains essentially the same. Thus, the difference between these two processed images should consist of the nodule superimposed on a relatively uniform background in which the detection task may be simplified. This difference image approach is fundamentally different from conventional subtraction techniques (e.g., temporal or dual-energy subtraction) in that the two images which are subtracted arise from the same single-projection chest radiograph. Once the difference image is obtained, thresholding is performed along with tests for circularity, size and growth in order to extract the nodules. It should be noted that once an original chest image is input to the computer the nodule detection process is totally automated

  14. The use of intermuscular coherence analysis as a novel approach to detect age-related changes on postural muscle synergy.

    Science.gov (United States)

    Degani, Adriana M; Leonard, Charles T; Danna-Dos-Santos, Alessander

    2017-08-24

    The overall goal of this study was to investigate potential adaptations brought about by the natural processes of aging on the coordination of postural muscles. Considering the progressive and non-homogeneous deterioration of sensorimotor and neuromuscular systems as the individual grows older, it was hypothesized that aging is associated with a reorganization of synergistic mechanisms controlling postural muscles. Therefore, the presence, distribution, and strength of correlated neural inputs to three posterior postural muscles were measured by intermuscular coherence estimations at a low frequency band (0-55Hz). Nine healthy young adults and thirteen healthy older adults performed ten trials of a perturbed task: bipedal stance while holding a five kg load for fifteen seconds. Estimates of intermuscular coherence for each pair of electromyographic signals (soleus and biceps femoris, soleus and erector spinae, and biceps femoris and erector spinae) were computed. Results revealed significantly stronger levels of synchronization of posterior muscles within 0-10Hz in seniors compared to young adults. In addition, seniors presented similar spectra of intermuscular coherence within 0-55Hz for all three muscle pairs analyzed. These findings provide valuable information regarding compensatory mechanisms adopted by older adults to control balance. The age-related reorganization of neural drive controlling posterior postural muscles revealing a stronger synchronization within 0-10Hz might be related to the faster body sway and muscle co-activation patterns usually observed in this population. Finally, this study supports the use of Intermuscular Coherence Analysis as a sensitive method to detect age-related changes in multi-muscle control. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Fundamental limits to single-photon detection determined by quantum coherence and backaction

    Science.gov (United States)

    Young, Steve M.; Sarovar, Mohan; Léonard, François

    2018-03-01

    Single-photon detectors have achieved impressive performance and have led to a number of new scientific discoveries and technological applications. Existing models of photodetectors are semiclassical in that the field-matter interaction is treated perturbatively and time-separated from physical processes in the absorbing matter. An open question is whether a fully quantum detector, whereby the optical field, the optical absorption, and the amplification are considered as one quantum system, could have improved performance. Here we develop a theoretical model of such photodetectors and employ simulations to reveal the critical role played by quantum coherence and amplification backaction in dictating the performance. We show that coherence and backaction lead to trade-offs between detector metrics and also determine optimal system designs through control of the quantum-classical interface. Importantly, we establish the design parameters that result in a ideal photodetector with 100% efficiency, no dark counts, and minimal jitter, thus paving the route for next-generation detectors.

  16. A robust and coherent network statistic for detecting gravitational waves from inspiralling compact binaries in non-Gaussian noise

    CERN Document Server

    Bose, S

    2002-01-01

    The robust statistic proposed by Creighton (Creighton J D E 1999 Phys. Rev. D 60 021101) and Allen et al (Allen et al 2001 Preprint gr-gc/010500) for the detection of stationary non-Gaussian noise is briefly reviewed. We compute the robust statistic for generic weak gravitational-wave signals in the mixture-Gaussian noise model to an accuracy higher than in those analyses, and reinterpret its role. Specifically, we obtain the coherent statistic for detecting gravitational-wave signals from inspiralling compact binaries with an arbitrary network of earth-based interferometers. Finally, we show that excess computational costs incurred owing to non-Gaussianity is negligible compared to the cost of detection in Gaussian noise.

  17. Detect Image Tamper by Semi-Fragile Digital Watermarking

    Institute of Scientific and Technical Information of China (English)

    LIUFeilong; WANGYangsheng

    2004-01-01

    To authenticate the integrity of image while resisting some valid image processing such as JPEG compression, a semi-fragile image watermarking is described. Image name, one of the image features, has been used as the key of pseudo-random function to generate the special watermarks for the different image. Watermarks are embedded by changing the relationship between the blocks' DCT DC coefficients, and the image tamper are detected with the relationship of these DCT DC coefficients.Experimental results show that the proposed technique can resist JPEG compression, and detect image tamper in the meantime.

  18. Application of digital lock-in detection to Hefei Light Source turn-by-turn system

    International Nuclear Information System (INIS)

    Yang Yongliang; Wang Junhua; Sun Baogen; Chen Yuanbo; Zhou Zeran

    2010-01-01

    This paper introduces the digital lock-in detection theory and discusses its feasibility to obtain the damping rate in turn-by-turn measurement systems. Numerical simulations of this method were carried out with Matlab. Then principle presenting beam experiments were conducted on the Hefei Light Source (HLS) storage ring. The measured beta oscillation growth time is about 0.26 ms and the damping time is about 1.2 ms. Simulation and experimental results show that, the digital lock-in detection method is effective in damping rate measurement in turn-by-turn measurement systems. (authors)

  19. Forming and detection of digital watermarks in the System for Automatic Identification of VHF Transmissions

    Directory of Open Access Journals (Sweden)

    О. В. Шишкін

    2013-07-01

    Full Text Available Forming and detection algorithms for digital watermarks are designed for automatic identification of VHF radiotelephone transmissions in the maritime and aeronautical mobile services. An audible insensitivity and interference resistance of embedded digital data are provided by means of OFDM technology jointly with normalized distortions distribution and data packet detection by the hash-function. Experiments were carried out on the base of ship’s radio station RT-2048 Sailor and USB ADC-DAC module of type Е14-140M L-CARD in the off-line processing regime in Matlab medium

  20. DIGITAL DETECTION SYSTEM DESIGN OF MYCOBACTERIUM TUBERCULOSIS THROUGH EXTRACTION OF SPUTUM IMAGE USING NEURAL NETWORK METHOD

    Directory of Open Access Journals (Sweden)

    Franky Arisgraha

    2012-01-01

    Full Text Available Tuberculosis (TBC is an dangerous disease and many people has been infected. One of many important steps to control TBC effectively and efficiently is by increasing case finding using right method and accurate diagnostic. One of them is to detect Mycobacterium Tuberculosis inside sputum. Conventional detection of Mycobacterium Tuberculosis inside sputum can need a lot of time, so digitally detection method of Mycobacterium Tuberculosis was designed as an effort to get better result of detection. This method was designed by using combination between digital image processing method and Neural Network method. From testing report that was done, Mycobacterium can be detected with successful value reach 77.5% and training error less than 5%.

  1. An algorithm of local earthquake detection from digital records

    Directory of Open Access Journals (Sweden)

    A. PROZOROV

    1978-06-01

    Full Text Available The problem of automatical detection of earthquake signals in seismograms
    and definition of first arrivals of p and s waves is considered.
    The algorithm is based on the analysis of t(A function which represents
    the time of first appearence of a number of going one after another
    swings of amplitudes greather than A in seismic signals. It allows to explore
    such common features of seismograms of earthquakes as sudden
    first p-arrivals of amplitude greater than general amplitude of noise and
    after the definite interval of time before s-arrival the amplitude of which
    overcomes the amplitude of p-arrival. The method was applied to
    3-channel recods of Friuli aftershocks, ¿'-arrivals were defined correctly
    in all cases; p-arrivals were defined in most cases using strict criteria of
    detection. Any false signals were not detected. All p-arrivals were defined
    using soft criteria of detection but less reliability and two false events
    were obtained.

  2. Automated detection and categorization of genital injuries using digital colposcopy

    DEFF Research Database (Denmark)

    Fernandes, Kelwin; Cardoso, Jaime S.; Astrup, Birgitte Schmidt

    2017-01-01

    handcrafted features and deep learning techniques in the automated processing of colposcopic images for genital injury detection. Positive results where achieved by both paradigms in segmentation and classification subtasks, being traditional and deep models the best strategy for each subtask type...

  3. Optimized digital filtering techniques for radiation detection with HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Salathe, Marco, E-mail: marco.salathe@mpi-hd.mpg.de; Kihm, Thomas, E-mail: mizzi@mpi-hd.mpg.de

    2016-02-01

    This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: a pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated with a 762 g Broad Energy Germanium (BEGe) detector, produced by Canberra, that measures γ-ray lines from radioactive sources in an energy range between 59.5 and 2614.5 keV. At 1332.5 keV, together with the ballistic deficit correction method, all filters produce a comparable energy resolution of ~1.61 keV FWHM. This value is superior to those measured by the manufacturer and those found in publications with detectors of a similar design and mass. At 59.5 keV, the modified cusp filter without a ballistic deficit correction produced the best result, with an energy resolution of 0.46 keV. It is observed that the loss in resolution by using a constant shaping time over the entire energy range is small when using the ballistic deficit correction method.

  4. Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions

    International Nuclear Information System (INIS)

    Obenauer, S.; Luftner-Nagel, S.; Heyden, D. von; Baum, F.; Grabbe, E.; Munzel, U.

    2002-01-01

    The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADSZZZ;) categories (FFDM better than

  5. Theoretical calculation on ICI reduction using digital coherent superposition of optical OFDM subcarrier pairs in the presence of laser phase noise.

    Science.gov (United States)

    Yi, Xingwen; Xu, Bo; Zhang, Jing; Lin, Yun; Qiu, Kun

    2014-12-15

    Digital coherent superposition (DCS) of optical OFDM subcarrier pairs with Hermitian symmetry can reduce the inter-carrier-interference (ICI) noise resulted from phase noise. In this paper, we show two different implementations of DCS-OFDM that have the same performance in the presence of laser phase noise. We complete the theoretical calculation on ICI reduction by using the model of pure Wiener phase noise. By Taylor expansion of the ICI, we show that the ICI power is cancelled to the second order by DCS. The fourth order term is further derived out and only decided by the ratio of laser linewidth to OFDM subcarrier symbol rate, which can greatly simplify the system design. Finally, we verify our theoretical calculations in simulations and use the analytical results to predict the system performance. DCS-OFDM is expected to be beneficial to certain optical fiber transmissions.

  6. A Pedestrian Detection Scheme Using a Coherent Phase Difference Method Based on 2D Range-Doppler FMCW Radar

    Science.gov (United States)

    Hyun, Eugin; Jin, Young-Seok; Lee, Jong-Hun

    2016-01-01

    For an automotive pedestrian detection radar system, fast-ramp based 2D range-Doppler Frequency Modulated Continuous Wave (FMCW) radar is effective for distinguishing between moving targets and unwanted clutter. However, when a weak moving target such as a pedestrian exists together with strong clutter, the pedestrian may be masked by the side-lobe of the clutter even though they are notably separated in the Doppler dimension. To prevent this problem, one popular solution is the use of a windowing scheme with a weighting function. However, this method leads to a spread spectrum, so the pedestrian with weak signal power and slow Doppler may also be masked by the main-lobe of clutter. With a fast-ramp based FMCW radar, if the target is moving, the complex spectrum of the range- Fast Fourier Transform (FFT) is changed with a constant phase difference over ramps. In contrast, the clutter exhibits constant phase irrespective of the ramps. Based on this fact, in this paper we propose a pedestrian detection for highly cluttered environments using a coherent phase difference method. By detecting the coherent phase difference from the complex spectrum of the range-FFT, we first extract the range profile of the moving pedestrians. Then, through the Doppler FFT, we obtain the 2D range-Doppler map for only the pedestrian. To test the proposed detection scheme, we have developed a real-time data logging system with a 24 GHz FMCW transceiver. In laboratory tests, we verified that the signal processing results from the proposed method were much better than those expected from the conventional 2D FFT-based detection method. PMID:26805835

  7. A Pedestrian Detection Scheme Using a Coherent Phase Difference Method Based on 2D Range-Doppler FMCW Radar

    Directory of Open Access Journals (Sweden)

    Eugin Hyun

    2016-01-01

    Full Text Available For an automotive pedestrian detection radar system, fast-ramp based 2D range-Doppler Frequency Modulated Continuous Wave (FMCW radar is effective for distinguishing between moving targets and unwanted clutter. However, when a weak moving target such as a pedestrian exists together with strong clutter, the pedestrian may be masked by the side-lobe of the clutter even though they are notably separated in the Doppler dimension. To prevent this problem, one popular solution is the use of a windowing scheme with a weighting function. However, this method leads to a spread spectrum, so the pedestrian with weak signal power and slow Doppler may also be masked by the main-lobe of clutter. With a fast-ramp based FMCW radar, if the target is moving, the complex spectrum of the range- Fast Fourier Transform (FFT is changed with a constant phase difference over ramps. In contrast, the clutter exhibits constant phase irrespective of the ramps. Based on this fact, in this paper we propose a pedestrian detection for highly cluttered environments using a coherent phase difference method. By detecting the coherent phase difference from the complex spectrum of the range-FFT, we first extract the range profile of the moving pedestrians. Then, through the Doppler FFT, we obtain the 2D range-Doppler map for only the pedestrian. To test the proposed detection scheme, we have developed a real-time data logging system with a 24 GHz FMCW transceiver. In laboratory tests, we verified that the signal processing results from the proposed method were much better than those expected from the conventional 2D FFT-based detection method.

  8. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  9. DIGITAL

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — The Digital Flood Insurance Rate Map (DFIRM) Database depicts flood risk information and supporting data used to develop the risk data. The primary risk...

  10. Evaluation of a New Digital Automated Glycemic Pattern Detection Tool.

    Science.gov (United States)

    Comellas, María José; Albiñana, Emma; Artes, Maite; Corcoy, Rosa; Fernández-García, Diego; García-Alemán, Jorge; García-Cuartero, Beatriz; González, Cintia; Rivero, María Teresa; Casamira, Núria; Weissmann, Jörg

    2017-11-01

    Blood glucose meters are reliable devices for data collection, providing electronic logs of historical data easier to interpret than handwritten logbooks. Automated tools to analyze these data are necessary to facilitate glucose pattern detection and support treatment adjustment. These tools emerge in a broad variety in a more or less nonevaluated manner. The aim of this study was to compare eDetecta, a new automated pattern detection tool, to nonautomated pattern analysis in terms of time investment, data interpretation, and clinical utility, with the overarching goal to identify early in development and implementation of tool areas of improvement and potential safety risks. Multicenter web-based evaluation in which 37 endocrinologists were asked to assess glycemic patterns of 4 real reports (2 continuous subcutaneous insulin infusion [CSII] and 2 multiple daily injection [MDI]). Endocrinologist and eDetecta analyses were compared on time spent to analyze each report and agreement on the presence or absence of defined patterns. eDetecta module markedly reduced the time taken to analyze each case on the basis of the emminens eConecta reports (CSII: 18 min; MDI: 12.5), compared to the automatic eDetecta analysis. Agreement between endocrinologists and eDetecta varied depending on the patterns, with high level of agreement in patterns of glycemic variability. Further analysis of low level of agreement led to identifying areas where algorithms used could be improved to optimize trend pattern identification. eDetecta was a useful tool for glycemic pattern detection, helping clinicians to reduce time required to review emminens eConecta glycemic reports. No safety risks were identified during the study.

  11. Object detection and recognition in digital images theory and practice

    CERN Document Server

    Cyganek, Boguslaw

    2013-01-01

    Object detection, tracking and recognition in images are key problems in computer vision. This book provides the reader with a balanced treatment between the theory and practice of selected methods in these areas to make the book accessible to a range of researchers, engineers, developers and postgraduate students working in computer vision and related fields. Key features: Explains the main theoretical ideas behind each method (which are augmented with a rigorous mathematical derivation of the formulas), their implementation (in C++) and demonstrated working in real applications.

  12. Edge detection in digital images using Ant Colony Optimization

    Directory of Open Access Journals (Sweden)

    Marjan Kuchaki Rafsanjani

    2015-11-01

    Full Text Available Ant Colony Optimization (ACO is an optimization algorithm inspired by the behavior of real ant colonies to approximate the solutions of difficult optimization problems. In this paper, ACO is introduced to tackle the image edge detection problem. The proposed approach is based on the distribution of ants on an image; ants try to find possible edges by using a state transition function. Experimental results show that the proposed method compared to standard edge detectors is less sensitive to Gaussian noise and gives finer details and thinner edges when compared to earlier ant-based approaches.

  13. Automated Meteor Detection by All-Sky Digital Camera Systems

    Czech Academy of Sciences Publication Activity Database

    Suk, Tomáš; Šimberová, Stanislava

    2017-01-01

    Roč. 120, č. 3 (2017), s. 189-215 ISSN 0167-9295 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985815 ; RVO:67985556 Keywords : meteor detection * autonomous fireball observatories * fish-eye camera * Hough transformation Subject RIV: IN - Informatics, Computer Science; BN - Astronomy, Celestial Mechanics, Astrophysics (ASU-R) OBOR OECD: Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8); Astronomy (including astrophysics,space science) (ASU-R) Impact factor: 0.875, year: 2016

  14. Photonic microwave carrier recovery using period-one nonlinear dynamics of semiconductor lasers for OFDM-RoF coherent detection.

    Science.gov (United States)

    Hung, Yu-Han; Yan, Jhih-Heng; Feng, Kai-Ming; Hwang, Sheng-Kwang

    2017-06-15

    This study investigates an all-optical scheme based on period-one (P1) nonlinear dynamics of semiconductor lasers, which regenerates the microwave carrier of an orthogonal frequency division multiplexing radio-over-fiber (OFDM-RoF) signal and uses it as a microwave local oscillator for coherent detection. Through the injection locking established between the OFDM-RoF signal and the P1 dynamics, frequency synchronization with highly preserved phase quality is inherently achieved between the recovered microwave carrier and the microwave carrier of the OFDM-RoF signal. A bit-error ratio down to 1.9×10-9 is achieved accordingly using the proposed scheme for coherent detection of a 32-GHz OFDM-RoF signal carrying 4  Gb/s 16-quadrature amplitude modulation data. No electronic microwave generators or electronic phase-locked loops are thus required. The proposed system can be operated up to at least 100 GHz and can be self-adapted to certain changes in the operating microwave frequency.

  15. Continental Shelf-Scale Passive Acoustic Detection and Characterization of Diesel-Electric Ships Using a Coherent Hydrophone Array

    Directory of Open Access Journals (Sweden)

    Wei Huang

    2017-07-01

    Full Text Available The passive ocean acoustic waveguide remote sensing (POAWRS technique is employed to detect and characterize the underwater sound radiated from three scientific research and fishing vessels received at long ranges on a large-aperture densely-sampled horizontal coherent hydrophone array. The sounds radiated from the research vessel (RV Delaware II in the Gulf of Maine, and the RV Johan Hjort and the fishing vessel (FV Artus in the Norwegian Sea are found to be dominated by distinct narrowband tonals and cyclostationary signals in the 150 Hz to 2000 Hz frequency range. The source levels of these signals are estimated by correcting the received pressure levels for transmission losses modeled using a calibrated parabolic equation-based acoustic propagation model for random range-dependent ocean waveguides. The probability of the detection region for the most prominent signal radiated by each ship is estimated and shown to extend over areas spanning roughly 200 km in diameter when employing a coherent hydrophone array. The current standard procedure for quantifying ship-radiated sound source levels via one-third octave bandwidth intensity averaging smoothes over the prominent tonals radiated by a ship that can stand 10 to 30 dB above the local broadband level, which may lead to inaccurate or incorrect assessments of the impact of ship-radiated sound.

  16. Interferometric Reflectance Imaging Sensor (IRIS—A Platform Technology for Multiplexed Diagnostics and Digital Detection

    Directory of Open Access Journals (Sweden)

    Oguzhan Avci

    2015-07-01

    Full Text Available Over the last decade, the growing need in disease diagnostics has stimulated rapid development of new technologies with unprecedented capabilities. Recent emerging infectious diseases and epidemics have revealed the shortcomings of existing diagnostics tools, and the necessity for further improvements. Optical biosensors can lay the foundations for future generation diagnostics by providing means to detect biomarkers in a highly sensitive, specific, quantitative and multiplexed fashion. Here, we review an optical sensing technology, Interferometric Reflectance Imaging Sensor (IRIS, and the relevant features of this multifunctional platform for quantitative, label-free and dynamic detection. We discuss two distinct modalities for IRIS: (i low-magnification (ensemble biomolecular mass measurements and (ii high-magnification (digital detection of individual nanoparticles along with their applications, including label-free detection of multiplexed protein chips, measurement of single nucleotide polymorphism, quantification of transcription factor DNA binding, and high sensitivity digital sensing and characterization of nanoparticles and viruses.

  17. Coherent anti-Stokes Raman scattering (CARS) detection or hot atom reaction product internal energy distributions

    International Nuclear Information System (INIS)

    Quick, C.R. Jr.; Moore, D.S.

    1983-01-01

    Coherent anti-Stokes Raman spectroscopy (CARS) is being utilized to investigate the rovibrational energy distributions produced by reactive and nonreactive collisions of translationally hot atoms with simple molecules. Translationally hot H atoms are produced by ArF laser photolysis of HBr. Using CARS we have monitored, in a state-specific and time-resolved manner, rotational excitation of HBr (v = 0), vibrational excitation of HBr and H 2 , rovibrational excitation of H 2 produced by the reaction H + HBr → H 2 + Br, and Br atom production by photolysis of HBr

  18. Performance analysis and technical assessment of coherent lidar systems for airborne wind shear detection

    Science.gov (United States)

    Huffaker, R. Milton; Targ, Russell

    1988-01-01

    Detailed computer simulations of the lidar wind-measuring process have been conducted to evaluate the use of pulsed coherent lidar for airborne windshear monitoring. NASA data fields for an actual microburst event were used in the simulation. Both CO2 and Ho:YAG laser lidar systems performed well in the microburst test case, and were able to measure wind shear in the severe weather of this wet microburst to ranges in excess of 1.4 km. The consequent warning time gained was about 15 sec.

  19. Coherent detection of THz-induced sideband emission from excitons in the nonperturbative regime

    Science.gov (United States)

    Uchida, K.; Otobe, T.; Mochizuki, T.; Kim, C.; Yoshita, M.; Tanaka, K.; Akiyama, H.; Pfeiffer, L. N.; West, K. W.; Hirori, H.

    2018-04-01

    Strong interaction of a terahertz (THz) wave with excitons induces nonperturbative optical effects such as Rabi splitting and high-order sideband generation. Here, we investigated coherent properties of THz-induced sideband emissions from GaAs/AlGaAs multiquantum wells. With increasing THz electric field, optical susceptibility of the THz-dressed exciton shows a redshift with spectral broadening and extraordinary phase shift. This implies that the field ionization of the 1 s exciton modifies the THz-dressed exciton in the nonperturbative regime.

  20. Nodule detection in digital chest radiography: Effect of anatomical noise

    International Nuclear Information System (INIS)

    Baath, M.; Haakansson, M.; Boerjesson, S.; Hoeschen, C.; Tischenko, O.; Kheddache, S.; Vikgren, J.; Maansson, L. G.

    2005-01-01

    The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (referred to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high delectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions). (authors)

  1. A digital controlled PV-inverter with grid impedance estimation for ENS detection

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    in dispersed power generation networks. For instance, the knowledge of the utility impedance at the fundamental frequency can be used to detect a utility failure. A PV-inverter with this feature can anticipate a possible network problem and decouple it in time. This paper describes the digital implementation...

  2. Lung cancer detection with digital chest tomosynthesis: first round results from the SOS observational study.

    Science.gov (United States)

    Bertolaccini, Luca; Viti, Andrea; Tavella, Chiara; Priotto, Roberto; Ghirardo, Donatella; Grosso, Maurizio; Terzi, Alberto

    2015-04-01

    Baseline results of the Studio OSservazionale (SOS), observational study, a single-arm observational study of digital chest tomosynthesis for lung cancer detection in an at-risk population demonstrated a detection rate of lung cancer comparable to that of studies that used low dose CT scan (LDCT). We present the results of the first round. Totally 1,703 out of 1,843 (92%) subjects who had a baseline digital chest tomosynthesis underwent a first round reevaluation after 1 year. At first round chest digital tomosynthesis, 13 (0.7%) subjects had an indeterminate nodule larger than 5 mm and underwent low-dose CT scan for nodule confirmation. PET/CT study was obtained in 10 (0.5%) subjects and 2 subjects had a low-dose CT follow up. Surgery, either video-assisted thoracoscopic or open surgery for indeterminate pulmonary nodules was performed in 10 (0.2%) subjects. A lung cancer was diagnosed and resected in five patients. The lung cancer detection rate at first round was 0.3% (5/1,703). The detection rate of lung cancer at first round for tomosynthesis is comparable to rates reported for CT. In addition, results of first round digital chest tomosynthesis confirm chest tomosynthesis as a possible first-line lung cancer-screening tool.

  3. Design of a 1 Tb/s superchannel coherent receiver

    NARCIS (Netherlands)

    Millar, D.S.; Maher, R.; Lavery, D.; Koike-Akino, T.; Pajovic, M.; Alvarado, A.; Paskov, M.; Kojima, K.; Parsons, K.; Thomsen, B.C.; Savory, S.J.; Bayvel, P.

    2016-01-01

    We describe the design of a trained and pilot-aided digital coherent receiver, capable of detecting a 1 Tb/s superchannel with a single optical front-end. Algorithms for receiver training are described, which calculate the equalizer coefficients, subchannel SNRs, and centroids of the transmitted

  4. Performance evaluation and optimization of multiband phase-modulated radio over IsOWC link with balanced coherent homodyne detection

    Science.gov (United States)

    Zong, Kang; Zhu, Jiang

    2018-04-01

    In this paper, we present a multiband phase-modulated (PM) radio over intersatellite optical wireless communication (IsOWC) link with balanced coherent homodyne detection. The proposed system can provide the transparent transport of multiband radio frequency (RF) signals with higher linearity and better receiver sensitivity than intensity modulated with direct detection (IM/DD) system. The expressions of RF gain, noise figure (NF) and third-order spurious-free dynamic range (SFDR) are derived considering the third-order intermodulation product and amplifier spontaneous emission (ASE) noise. The optimal power of local oscillator (LO) optical signal is also derived theoretically. Numerical results for RF gain, NF and third-order SFDR are given for demonstration. Results indicate that the gain of the optical preamplifier and the power of LO optical signal should be optimized to obtain the satisfactory performance.

  5. Fissile material detection and control facility with pulsed neutron sources and digital data processing

    International Nuclear Information System (INIS)

    Romodanov, V.L.; Chernikova, D.N.; Afanasiev, V.V.

    2010-01-01

    Full text: In connection with possible nuclear terrorism, there is long-felt need of devices for effective control of radioactive and fissile materials in the key points of crossing the state borders (airports, seaports, etc.), as well as various customs check-points. In International Science and Technology Center Projects No. 596 and No. 2978, a new physical method and digital technology have been developed for the detection of fissile and radioactive materials in models of customs facilities with a graphite moderator, pulsed neutron source and digital processing of responses from scintillation PSD detectors. Detectability of fissile materials, even those shielded with various radiation-absorbing screens, has been shown. The use of digital processing of scintillation signals in this facility is a necessary element, as neutrons and photons are discriminated in the time dependence of fissile materials responses at such loads on the electronic channels that standard types of spectrometers are inapplicable. Digital processing of neutron and photon responses practically resolves the problem of dead time and allows implementing devices, in which various energy groups of neutrons exist for some time after a pulse of source neutrons. Thus, it is possible to detect fissile materials deliberately concealed with shields having a large cross-section of absorption of photons and thermal neutrons. Two models of detection and the control of fissile materials were advanced: 1. the model based on graphite neutrons moderator and PSD scintillators with digital technology of neutrons and photons responses separation; 2. the model based on plastic scintillators and detecting of time coincidences of fission particles by digital technology. Facilities that count time coincidences of neutrons and photons occurring in the fission of fissile materials can use an Am Li source of neutrons, e.g. that is the case with the AWCC system. The disadvantages of the facility are related to the issues

  6. Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers

    Science.gov (United States)

    Xie, Tuqiang; Xie, Huikai; Fedder, Gary K.; Pan, Yingtian

    2003-11-01

    Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37°, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm × 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm × 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

  7. Detecting the manipulation of digital clinical records in dental practice

    International Nuclear Information System (INIS)

    Díaz-Flores-García, V.; Labajo-González, E.; Santiago-Sáez, A.; Perea-Pérez, B.

    2017-01-01

    Introduction: Radiography provides many advantages in the diagnosis and management of dental conditions. However, dental X-ray images may be subject to manipulation with malicious intent using easily accessible computer software. Methods: In this study, we sought to evaluate a dentist's ability to identify a manipulated dental X-ray images, when compared with the original, using a variant of the methodology described by Visser and Kruger. Sixty-six dentists were invited to participate and evaluate 20 intraoral dental X-ray images, 10 originals and 10 modified, manipulated using Adobe Photoshop to simulate fillings, root canal treatments, etc. Results: Participating dentists were correct in identifying the manipulated image in 56% of cases, 6% higher than by chance and 10% more than in the study by Visser and Kruger. Conclusion: Malicious changes to dental X-ray images may go unnoticed even by experienced dentists. Professionals must be aware of the legal consequences of such changes. A system of detection/validation should be created for radiographic images. - Highlights: • Fraudulent manipulation of dental X-ray images creates a problem of legal security. • Dentists were able to identify manipulated images on 56% of all occasions. • 6% more than the probability of a person with no dental training. • 10% more than in the study by Visser and Kruger.

  8. Detecting the manipulation of digital clinical records in dental practice.

    Science.gov (United States)

    Díaz-Flores-García, V; Labajo-González, E; Santiago-Sáez, A; Perea-Pérez, B

    2017-11-01

    Radiography provides many advantages in the diagnosis and management of dental conditions. However, dental X-ray images may be subject to manipulation with malicious intent using easily accessible computer software. In this study, we sought to evaluate a dentist's ability to identify a manipulated dental X-ray images, when compared with the original, using a variant of the methodology described by Visser and Kruger. Sixty-six dentists were invited to participate and evaluate 20 intraoral dental X-ray images, 10 originals and 10 modified, manipulated using Adobe Photoshop to simulate fillings, root canal treatments, etc. Participating dentists were correct in identifying the manipulated image in 56% of cases, 6% higher than by chance and 10% more than in the study by Visser and Kruger. Malicious changes to dental X-ray images may go unnoticed even by experienced dentists. Professionals must be aware of the legal consequences of such changes. A system of detection/validation should be created for radiographic images. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  9. Improved Method of Detection Falsification Results the Digital Image in Conditions of Attacks

    Directory of Open Access Journals (Sweden)

    Kobozeva A.A.

    2016-08-01

    Full Text Available The modern level of information technologies development has led to unheard ease embodiments hitherto unauthorized modifications of digital content. At the moment, very important question is the effective expert examination of authenticity of digital images, video, audio, development of the methods for identification and localization of violations of their integrity using these contents for purposes other than entertainment. Present paper deals with the improvement of the detection method of the cloning results in digital images - one of the most frequently used in the software tools falsification realized in all modern graphics editors. The method is intended for clone detection areas and pre-image in terms of additional disturbing influences in the image after the cloning operation for "masking" of the results, which complicates the search process. The improvement is aimed at reducing the number of "false alarms", when the area of the clone / pre-image detected in the original image or the localization of the identified areas do not correspond to the real clone and pre-image. The proposed improvement, based on analysis of different sizes per-pixel image blocks with the least difference from each other, has made it possible efficient functioning of the method, regardless of the specificity of the analyzed digital image.

  10. Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples

    Science.gov (United States)

    Razani, Marjan; Luk, Timothy W.H.; Mariampillai, Adrian; Siegler, Peter; Kiehl, Tim-Rasmus; Kolios, Michael C.; Yang, Victor X.D.

    2014-01-01

    In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs duration, applying acoustic radiation force (ARF) to inhomogeneous phantoms and carotid artery samples, synchronized with a swept-source OCT (SS-OCT) imaging system. The phantoms were composed of gelatin and titanium dioxide whereas the carotid artery samples were embedded in gel. Differential OCT phase maps, measured with and without the ARF, detected the microscopic displacement generated by shear wave propagation in these phantoms and samples of different stiffness. We present the technique for calculating tissue mechanical properties by propagating shear waves in inhomogeneous tissue equivalent phantoms and carotid artery samples using the ARF of an ultrasound transducer, and measuring the shear wave speed and its associated properties in the different layers with OCT phase maps. This method lays the foundation for future in-vitro and in-vivo studies of mechanical property measurements of biological tissues such as vascular tissues, where normal and pathological structures may exhibit significant contrast in the shear modulus. PMID:24688822

  11. Remote detection of chem/bio hazards via coherent anti-Stokes Raman spectroscopy

    Science.gov (United States)

    2017-09-12

    hour per response, including the time for reviewing lnstnJctions, searching existing data sources, gathering and maintaining the data needed, and... time remote detection of hazardous microparticles in atmosphere and to evaluate the range of distances for typical species and the parameters of laser...detectable photons from a prototype molecule at a distance. 1S. SUBJECT TERMS Stimulated Raman scattering, Remote detection, biochemical agents, explosives

  12. Review of passive-blind detection in digital video forgery based on sensing and imaging techniques

    Science.gov (United States)

    Tao, Junjie; Jia, Lili; You, Ying

    2016-01-01

    Advances in digital video compression and IP communication technologies raised new issues and challenges concerning the integrity and authenticity of surveillance videos. It is so important that the system should ensure that once recorded, the video cannot be altered; ensuring the audit trail is intact for evidential purposes. This paper gives an overview of passive techniques of Digital Video Forensics which are based on intrinsic fingerprints inherent in digital surveillance videos. In this paper, we performed a thorough research of literatures relevant to video manipulation detection methods which accomplish blind authentications without referring to any auxiliary information. We presents review of various existing methods in literature, and much more work is needed to be done in this field of video forensics based on video data analysis and observation of the surveillance systems.

  13. Passive Coherent Detection and Target Location with Multiple Non-Cooperative Transmitters

    Science.gov (United States)

    2015-06-01

    NUMBERS 6. AUTHOR(S) Qinling Jeanette Olivia Tan 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate School Monterey, CA 93943-5000...8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING /MONITORING AGENCY NAME(S) AND ADDRESS(ES) N/A 10. SPONSORING/MONITORING AGENCY...UHF TV (analogue) ~550 MHz Vestigial -Sideband AM (vision); FM(sound), 5.5 MHz 1 MW -51 dBW m -2 at r1 = 100 km Digital audio broadcast ~220

  14. Application of Novel Software Algorithms to Spectral-Domain Optical Coherence Tomography for Automated Detection of Diabetic Retinopathy.

    Science.gov (United States)

    Adhi, Mehreen; Semy, Salim K; Stein, David W; Potter, Daniel M; Kuklinski, Walter S; Sleeper, Harry A; Duker, Jay S; Waheed, Nadia K

    2016-05-01

    To present novel software algorithms applied to spectral-domain optical coherence tomography (SD-OCT) for automated detection of diabetic retinopathy (DR). Thirty-one diabetic patients (44 eyes) and 18 healthy, nondiabetic controls (20 eyes) who underwent volumetric SD-OCT imaging and fundus photography were retrospectively identified. A retina specialist independently graded DR stage. Trained automated software generated a retinal thickness score signifying macular edema and a cluster score signifying microaneurysms and/or hard exudates for each volumetric SD-OCT. Of 44 diabetic eyes, 38 had DR and six eyes did not have DR. Leave-one-out cross-validation using a linear discriminant at missed detection/false alarm ratio of 3.00 computed software sensitivity and specificity of 92% and 69%, respectively, for DR detection when compared to clinical assessment. Novel software algorithms applied to commercially available SD-OCT can successfully detect DR and may have potential as a viable screening tool for DR in future. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:410-417.]. Copyright 2016, SLACK Incorporated.

  15. New approach development for solution of cloning results detection problem in lossy saved digital image

    Directory of Open Access Journals (Sweden)

    A.A. Kobozeva

    2016-09-01

    Full Text Available The problem of detection of the digital image falsification results performed by cloning is considered – one of the most often used program tools implemented in all modern graphic editors. Aim: The aim of the work is further development of approach to the solution of a cloning detection problem having the cloned image saved in a lossy format, offered by authors earlier. Materials and Methods: Further development of a new approach to the solution of a problem of cloning results detection in the digital image is presented. Approach is based on the accounting of small changes of cylindrical body volume with the generatrix, that is parallel to the OZ axis, bounded above by the interpolating function plot for a matrix of brightness of the analyzed image, and bounded below by the XOY plane, during the compression process. Results: Adaptation of the offered approach to conditions of the cloned image compression with the arbitrary factor of compression quality is carried out (compression ratio. The approach solvency in the conditions of the cloned image compression according to the algorithms different from the JPEG standard is shown: JPEG2000, compression with use of low-rank approximations of the image matrix (matrix blocks. The results of computational experiment are given. It is shown that the developed approach can be used to detect the results of cloning in digital video in the conditions of lossy compression after cloning process.

  16. Detection of Clinically Significant Retinopathy of Prematurity Using Wide-angle Digital Retinal Photography

    Science.gov (United States)

    Chiang, Michael F.; Melia, Michele; Buffenn, Angela N.; Lambert, Scott R.; Recchia, Franco M.; Simpson, Jennifer L.; Yang, Michael B.

    2013-01-01

    Objective To evaluate the accuracy of detecting clinically significant retinopathy of prematurity (ROP) using wide-angle digital retinal photography. Methods Literature searches of PubMed and the Cochrane Library databases were conducted last on December 7, 2010, and yielded 414 unique citations. The authors assessed these 414 citations and marked 82 that potentially met the inclusion criteria. These 82 studies were reviewed in full text; 28 studies met inclusion criteria. The authors extracted from these studies information about study design, interventions, outcomes, and study quality. After data abstraction, 18 were excluded for study deficiencies or because they were superseded by a more recent publication. The methodologist reviewed the remaining 10 studies and assigned ratings of evidence quality; 7 studies were rated level I evidence and 3 studies were rated level III evidence. Results There is level I evidence from ≥5 studies demonstrating that digital retinal photography has high accuracy for detection of clinically significant ROP. Level III studies have reported high accuracy, without any detectable complications, from real-world operational programs intended to detect clinically significant ROP through remote site interpretation of wide-angle retinal photographs. Conclusions Wide-angle digital retinal photography has the potential to complement standard ROP care. It may provide advantages through objective documentation of clinical examination findings, improved recognition of disease progression by comparing previous photographs, and the creation of image libraries for education and research. Financial Disclosure(s) Proprietary or commercial disclosure may be found after the references. PMID:22541632

  17. Improved non-invasive Optical Coherence Tomography detection of different engineered nanoparticles in food-mimicking matrices.

    Science.gov (United States)

    Grombe, Ringo; Kirsten, Lars; Mehner, Mirko; Linsinger, Thomas P J; Koch, Edmund

    2016-12-01

    Food industry and regulators require fast and reliable analytical methods for quality control. This especially counts for the detection of engineered nanomaterials (ENMs) in food products. Respective EU regulation is in force, but the development of appropriate methods is still underway. This paper updates the scope of Optical Coherence Tomography (OCT) for ENM/food matrix analysis. A range of nanomaterials and composites - Au@SiO2, Ag, Ag@SiO2 and SiO2 - in a simplified food matrix was investigated. The earlier finding of linear dependencies between concentration in the dispersion and light responses could be reproduced. Being able to analyse non-invasively for a relevant industrial compound such as SiO2, makes OCT an excellent candidate for screening purposes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    Science.gov (United States)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  19. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  20. Value of optical coherence tomography in the detection of macular pathology before the removal of silicone oil

    Directory of Open Access Journals (Sweden)

    Rashad MA

    2016-01-01

    Full Text Available Mohammad Ahmad Rashad, Ahmed Abdel Aliem Mohamed, Asmaa Ismail Ahmed Department of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt Purpose: To assess the pathological macular changes with optical coherence tomography (OCT before the removal of silicone oil (SiO in eyes that had undergone pars plana vitrectomy for complicated forms of retinal detachment (RD.Patients and methods: Subjects included 48 patients (51 eyes with complicated RD including proliferative vitreoretinopathy, proliferative diabetic retinopathy, recurrent RD, penetrating trauma, uveitis, giant retinal tears, and macular holes. All the eyes had undergone SiO injection. Furthermore, all eyes had been planned for the removal of SiO 6–12 months after the primary surgery. Finally, all eyes had a fundus examination and OCT examination before the silicone oil removal.Results: OCT findings indicated epiretinal membrane in 41% of the eyes, macular edema in 17%, macular detachment in 13.5%, macular thinning in 13.5%, macular holes in 10%, and subretinal membranes in 2%. Preoperative OCT was normal in only 12% of the eyes, while a clinical fundus examination was normal in 43% (P<0.001. Eyes with normal OCT had significantly better mean logMAR (0.35 than eyes with pathological changes detected through OCT (1.28; P<0.001. Surgical modifications were made during the removal of SiO in 74.5% of the eyes.Conclusion: OCT detected significantly more pathological changes than a clinical fundus examination. This had an impact on both surgical step modification during the removal of SiO and predictability of visual outcome after the removal of SiO. Keywords: optical coherence tomography, silicone oil, pars plana vitrectomy, proliferative vitreoretinopathy, proliferative diabetic retinopathy

  1. Evaluation Of Digital Unsharp-Mask Filtering For The Detection Of Subtle Mammographic Microcalcifications

    Science.gov (United States)

    Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.

    1986-06-01

    We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted

  2. Automated detection of esophageal dysplasia in in vivo optical coherence tomography images of the human esophagus

    Science.gov (United States)

    Kassinopoulos, Michalis; Dong, Jing; Tearney, Guillermo J.; Pitris, Costas

    2018-02-01

    Catheter-based Optical Coherence Tomography (OCT) devices allow real-time and comprehensive imaging of the human esophagus. Hence, they provide the potential to overcome some of the limitations of endoscopy and biopsy, allowing earlier diagnosis and better prognosis for esophageal adenocarcinoma patients. However, the large number of images produced during every scan makes manual evaluation of the data exceedingly difficult. In this study, we propose a fully automated tissue characterization algorithm, capable of discriminating normal tissue from Barrett's Esophagus (BE) and dysplasia through entire three-dimensional (3D) data sets, acquired in vivo. The method is based on both the estimation of the scatterer size of the esophageal epithelial cells, using the bandwidth of the correlation of the derivative (COD) method, as well as intensity-based characteristics. The COD method can effectively estimate the scatterer size of the esophageal epithelium cells in good agreement with the literature. As expected, both the mean scatterer size and its standard deviation increase with increasing severity of disease (i.e. from normal to BE to dysplasia). The differences in the distribution of scatterer size for each tissue type are statistically significant, with a p value of < 0.0001. However, the scatterer size by itself cannot be used to accurately classify the various tissues. With the addition of intensity-based statistics the correct classification rates for all three tissue types range from 83 to 100% depending on the lesion size.

  3. An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, Garret T; Barton, Jennifer K [College of Optical Sciences, University of Arizona, Tucson, AZ (United States); Cardinal, Kristen O' Halloran [Biomedical and General Engineering, California Polytechnic State University (United States); Williams, Stuart K [Cardiovascular Innovation Institute, University of Louisville, Louisville, KY 40292 (United States)], E-mail: barton@u.arizona.edu

    2008-06-21

    Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 {mu}m, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the percentage of struts covered with an anti-thrombogenic cellular lining. We developed an image analysis program to locate covered and uncovered stent struts in OCT images of tissue-engineered blood vessels. The struts were found by exploiting the highly reflective and shadowing characteristics of the metallic stent material. Coverage was evaluated by comparing the luminal surface with the depth of the strut reflection. Strut coverage calculations were compared to manual assessment of OCT images and epi-fluorescence analysis of the stented grafts. Based on the manual assessment, the strut identification algorithm operated with a sensitivity of 93% and a specificity of 99%. The strut coverage algorithm was 81% sensitive and 96% specific. The present study indicates that the program can automatically determine percent cellular coverage from volumetric OCT datasets of blood vessel mimics. The program could potentially be extended to assessments of stent endothelialization in native stented arteries.

  4. Digital tool for detecting diabetic retinopathy in retinography image using gabor transform

    Science.gov (United States)

    Morales, Y.; Nuñez, R.; Suarez, J.; Torres, C.

    2017-01-01

    Diabetic retinopathy is a chronic disease and is the leading cause of blindness in the population. The fundamental problem is that diabetic retinopathy is usually asymptomatic in its early stage and, in advanced stages, it becomes incurable, hence the importance of early detection. To detect diabetic retinopathy, the ophthalmologist examines the fundus by ophthalmoscopy, after sends the patient to get a Retinography. Sometimes, these retinography are not of good quality. This paper show the implementation of a digital tool that facilitates to ophthalmologist provide better patient diagnosis suffering from diabetic retinopathy, informing them that type of retinopathy has and to what degree of severity is find . This tool develops an algorithm in Matlab based on Gabor transform and in the application of digital filters to provide better and higher quality of retinography. The performance of algorithm has been compared with conventional methods obtaining resulting filtered images with better contrast and higher.

  5. AN AMELIORATED DETECTION STATISTICS FOR ADAPTIVE MASK MEDIAN FILTRATION OF HEAVILY NOISED DIGITAL IMAGES

    Directory of Open Access Journals (Sweden)

    Geeta Hanji

    2016-11-01

    Full Text Available Noise reduction is an important area of research in image processing applications. The performance of the digital image noise filtering method primarily depends upon the accuracy of noise detection scheme. This paper presents an effective detector based, adaptive mask, median filtration of heavily noised digital images affected with fixed value (or salt and pepper impulse noise. The proposed filter presents a novel approach; an ameliorated Rank Ordered Absolute Deviation (ROAD statistics to judge whether the input pixel is noised or noise free. If a pixel is detected as corrupted, it is subjected to adaptive mask median filtration; otherwise, it is kept unchanged. Extensive experimental results and comparative performance evaluations demonstrate that the proposed filter outperforms the existing decision type, median based filters with powerful noise detectors in terms of objective performance measures and visual retrieviation accuracy.

  6. Nodule detection in digital chest radiography: Introduction to the radius chest trial

    International Nuclear Information System (INIS)

    Baath, M.; Haakansson, M.; Boerjesson, S.; Kheddache, S.; Grahn, A.; Ruschin, M.; Tingberg, A.; Mattsson, S.; Maansson, L. G.

    2005-01-01

    Most digital radiographic systems of today have wide latitude and are hence able to provide images with a small constraint on dose level. This opens up for an unprejudiced dose optimisation. However, in order to succeed in the optimisation task, good knowledge of the imaging and detection processes is needed. As a part of the European-wide research project 'unification of physical and clinical requirements for medical X-ray imaging - governed by the Radiological Imaging Unification Strategies (RADIUS) Group - a major image quality trial was conducted by members of the group. The RADIUS chest trial was focused on the detection of lung nodules in digital chest radiography with the aims of determining to what extent (1) the detection of a nodule is dependent on its location, (2) the system noise disturbs the detection of lung nodules, (3) the anatomical noise disturbs the detection of lung nodules and (4) the image background and anatomical background act as pure noise for the detection of lung nodules. The purpose of the present paper is to give an introduction to the trial and describe the framework and set-up of the investigation. (authors)

  7. Detection of Lipid-Rich Prostate Circulating Tumour Cells with Coherent Anti-Stokes Raman Scattering Microscopy

    International Nuclear Information System (INIS)

    Mitra, Ranjana; Chao, Olivia; Urasaki, Yasuyo; Goodman, Oscar B; Le, Thuc T

    2012-01-01

    Circulating tumour cells (CTC) are an important indicator of metastasis and associated with a poor prognosis. Detection sensitivity and specificity of CTC in the peripheral blood of metastatic cancer patient remain a technical challenge. Coherent anti-Stokes Raman scattering (CARS) microscopy was employed to examine the lipid content of CTC isolated from the peripheral blood of metastatic prostate cancer patients. CARS microscopy was also employed to evaluate lipid uptake and mobilization kinetics of a metastatic human prostate cancer cell line. One hundred CTC from eight metastatic prostate cancer patients exhibited strong CARS signal which arose from intracellular lipid. In contrast, leukocytes exhibited weak CARS signal which arose mostly from cellular membrane. On average, CARS signal intensity of prostate CTC was 7-fold higher than that of leukocytes (P<0.0000001). When incubated with human plasma, C4-2 metastatic human prostate cancer cells exhibited rapid lipid uptake kinetics and slow lipid mobilization kinetics. Higher expression of lipid transport proteins in C4-2 cells compared to non-transformed RWPE-1 and non-malignant BPH-1 prostate epithelial cells further indicated strong affinity for lipid of metastatic prostate cancer cells. Intracellular lipid could serve as a biomarker for prostate CTC which could be sensitively detected with CARS microscopy in a label-free manner. Strong affinity for lipid by metastatic prostate cancer cells could be used to improve detection sensitivity and therapeutic targeting of prostate CTC

  8. Simple Adaptive Single Differential Coherence Detection of BPSK Signals in IEEE 802.15.4 Wireless Sensor Networks.

    Science.gov (United States)

    Zhang, Gaoyuan; Wen, Hong; Wang, Longye; Xie, Ping; Song, Liang; Tang, Jie; Liao, Runfa

    2017-12-26

    In this paper, we propose an adaptive single differential coherent detection (SDCD) scheme for the binary phase shift keying (BPSK) signals in IEEE 802.15.4 Wireless Sensor Networks (WSNs). In particular, the residual carrier frequency offset effect (CFOE) for differential detection is adaptively estimated, with only linear operation, according to the changing channel conditions. It was found that the carrier frequency offset (CFO) and chip signal-to-noise ratio (SNR) conditions do not need a priori knowledge. This partly benefits from that the combination of the trigonometric approximation sin - 1 ( x ) ≈ x and a useful assumption, namely, the asymptotic or high chip SNR, is considered for simplification of the full estimation scheme. Simulation results demonstrate that the proposed algorithm can achieve an accurate estimation and the detection performance can completely meet the requirement of the IEEE 802.15.4 standard, although with a little loss of reliability and robustness as compared with the conventional optimal single-symbol detector.

  9. Optical coherence tomography in retinitis pigmentosa: reproducibility and capacity to detect macular and retinal nerve fiber layer thickness alterations.

    Science.gov (United States)

    Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas

    2012-09-01

    To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.

  10. Diagnostic ability of the periapical radiographs and digital image in the detection of the artificial proximal caries

    International Nuclear Information System (INIS)

    Heo, Min Suk; You, Dong Soo

    1994-01-01

    Recently, the digital image was introduced into radiological image. The digital image has the power of contrast enhancement, histogram control, and other digitally enhancement. At the point of the resolution, periapical radiograph is superior to the digital image, but enhanced digital procedure improves the diagnostic ability of the digital image. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries in conventional radiographs, digital radiographs and enhanced digital radiographs (histogram specification). ROC (Receiver Operating Characteristic) analysis and paired t-test were used for the evaluation of detectability, and following results were acquired: 1. The mean ROC area of conventional radiographs was 0.9274. 2. The mean ROC area of unenhanced digital image was 0.9168. 3. The mean ROC area of enhanced digital image was 0.9339. 4. The diagnostic ability of three imaging methods was not significant difference (p>0.05). So, the digital images had similar diagnostic ability of artificial proximal caries to conventional radiographs. If properly enhanced digital image, it may be superior to conventional radiographs.

  11. Detection and quantification of beef and pork materials in meat products by duplex droplet digital PCR

    OpenAIRE

    Cai, Yicun; He, Yuping; Lv, Rong; Chen, Hongchao; Wang, Qiang; Pan, Liangwen

    2017-01-01

    Meat products often consist of meat from multiple animal species, and inaccurate food product adulteration and mislabeling can negatively affect consumers. Therefore, a cost-effective and reliable method for identification and quantification of animal species in meat products is required. In this study, we developed a duplex droplet digital PCR (dddPCR) detection and quantification system to simultaneously identify and quantify the source of meat in samples containing a mixture of beef (Bos t...

  12. Choroidal thinning in diabetes type 1 detected by 3-dimensional 1060 nm optical coherence tomography.

    Science.gov (United States)

    Esmaeelpour, Marieh; Brunner, Simon; Ansari-Shahrezaei, Siamak; Shahrezaei, Siamak Ansari; Nemetz, Susanne; Povazay, Boris; Kajic, Vedran; Drexler, Wolfgang; Binder, Susanne

    2012-10-03

    To map choroidal (ChT) and retinal thickness (RT) in patients with diabetes type 1 with and without maculopathy and retinopathy in order to compare them with healthy subjects using high speed 3-dimensional (3D) 1060 nm optical coherence tomography (OCT). Thirty-three eyes from 33 diabetes type 1 subjects (23-57 years, 15 male) divided into groups of without pathology (NDR) and with pathology (DR; including microaneurysms, exudates, clinically significant macular-oedema and proliferative retinopathy) were compared with 20 healthy axial eye length and age-matched subjects (24-57 years, 9 male), imaged by high speed (60.000 A-scans/s) 3D 1060 nm OCT performed over 36° × 36° field of view. Ocular health status, disease duration, body mass index, haemoglobin-A1c, and blood pressure (bp) measurements were recorded. Subfoveal ChT, and 2D topographic maps between retinal pigment epithelium and the choroidal/scleral-interface, were automatically generated and statistically analyzed. Subfoveal ChT (mean ± SD, μm) for healthy eyes was 388 ± 109; significantly thicker than all diabetic groups, 291 ± 64 for NDR, and 303 ± 82 for DR (ANOVA P 0.05). Compared with healthy eyes and the NDR, the averaged DR ChT-map demonstrated temporal thinning that extended superiorly and temporal-inferiorly (unpaired t-test, P 0.05). ChT is decreased in diabetes type 1, independent of the absence of pathology and of diabetic disease duration. In eyes with pathology, 3D 1060 nm OCT averaged maps showed an extension of the thinning area matching retinal lesions and suggesting its involvement on onset or progression of disease.

  13. Using optical coherence tomography to detect bacterial biofilms on foley catheters (Conference Presentation)

    Science.gov (United States)

    Heidari, Andrew E.; Oh, Kyungjin; Chen, Zhongping

    2017-02-01

    Urinary tract infections(UTI) pose a serious problem for hospital patients accounting for 33% of all hospital acquired(nosocomial) infections with indwelling foley catheters. The presence of an indwelling foley catheter provides a scaffolding for circulating planktonic bacteria to adhere to and to form microbial biofilm communities that would typically be hindered by the body's innate immune system response. It is these biofilm communities that form on the inner lumen of foley catheters that provide a reservoir of pathogenic bacteria that could dislodge or disperse from the biofilm and infect urethra or bladder mucosal tissue in the urinary tract. Current diagnostic techniques of urine microbiological cultures are lacking in differentiating asymptomatic bacteriuria and symptomatic catheter-associated urinary tract infection(CAUTI) since almost all patients with chronic indwelling catheters are almost universally bacteriuruic. There is an unmet need of a diagnostic tool to assess the difference between the pathogenesis of asymptomatic bacteriuria and CAUTI, specifically at the site of the native biofilm formation. Optical Coherence Tomography(OCT) is an emerging high resolution, minimally invasive tomographic imaging technique that has shown promise in imaging biofilm structures previously in an endoscopic setting of the airway in-vivo and in microfluidic chambers. OCT can be adapted to image various sized biological surfaces and orifices such as airway branches and blood vessels by using a variety of minature endoscopic probes. In this work OCT will be used to image biofilm structure in-vitro on the inner lumen of extravasated critical care patient's foley catheters. Scanning electron microscopy will be conducted post OCT to confirm the presence of bacterial biofilm in OCT images.

  14. A rigorous analysis of digital pre-emphasis and DAC resolution for interleaved DAC Nyquist-WDM signal generation in high-speed coherent optical transmission systems

    Science.gov (United States)

    Weng, Yi; Wang, Junyi; He, Xuan; Pan, Zhongqi

    2018-02-01

    The Nyquist spectral shaping techniques facilitate a promising solution to enhance spectral efficiency (SE) and further reduce the cost-per-bit in high-speed wavelength-division multiplexing (WDM) transmission systems. Hypothetically, any Nyquist WDM signals with arbitrary shapes can be generated by the use of the digital signal processing (DSP) based electrical filters (E-filter). Nonetheless, in actual 100G/ 200G coherent systems, the performance as well as DSP complexity are increasingly restricted by cost and power consumption. Henceforward it is indispensable to optimize DSP to accomplish the preferred performance at the least complexity. In this paper, we systematically investigated the minimum requirements and challenges of Nyquist WDM signal generation, particularly for higher-order modulation formats, including 16 quadrature amplitude modulation (QAM) or 64QAM. A variety of interrelated parameters, such as channel spacing and roll-off factor, have been evaluated to optimize the requirements of the digital-to-analog converter (DAC) resolution and transmitter E-filter bandwidth. The impact of spectral pre-emphasis has been predominantly enhanced via the proposed interleaved DAC architecture by at least 4%, and hence reducing the required optical signal to noise ratio (OSNR) at a bit error rate (BER) of 10-3 by over 0.45 dB at a channel spacing of 1.05 symbol rate and an optimized roll-off factor of 0.1. Furthermore, the requirements of sampling rate for different types of super-Gaussian E-filters are discussed for 64QAM Nyquist WDM transmission systems. Finally, the impact of the non-50% duty cycle error between sub-DACs upon the quality of the generated signals for the interleaved DAC structure has been analyzed.

  15. Detection of SEA-type α-thalassemia in embryo biopsies by digital PCR.

    Science.gov (United States)

    Lee, Ta-Hsien; Hsu, Ya-Chiung; Chang, Chia Lin

    2017-08-01

    Accurate and efficient pre-implantation genetic diagnosis (PGD) based on the analysis of single or oligo-cells is needed for timely identification of embryos that are affected by deleterious genetic traits in in vitro fertilization (IVF) clinics. Polymerase chain reaction (PCR) is the backbone of modern genetic diagnoses, and a spectrum of PCR-based techniques have been used to detect various thalassemia mutations in prenatal diagnosis (PND) and PGD. Among thalassemias, SEA-type α-thalassemia is the most common variety found in Asia, and can lead to Bart's hydrops fetalis and serious maternal complications. To formulate an efficient digital PCR for clinical diagnosis of SEA-type α-thalassemia in cultured embryos, we conducted a pilot study to detect the α-globin and SEA-type deletion alleles in blastomere biopsies with a highly sensitive microfluidics-based digital PCR method. Genomic DNA from embryo biopsy samples were extracted, and crude DNA extracts were first amplified by a conventional PCR procedure followed by a nested PCR reaction with primers and probes that are designed for digital PCR amplification. Analysis of microfluidics-based PCR reactions showed that robust signals for normal α-globin and SEA-type deletion alleles, together with an internal control gene, can be routinely generated using crude embryo biopsies after a 10 6 -fold dilution of primary PCR products. The SEA-type deletion in cultured embryos can be sensitively diagnosed with the digital PCR procedure in clinics. The adoption of this robust PGD method could prevent the implantation of IVF embryos that are destined to develop Bart's hydrops fetalis in a timely manner. The results also help inform future development of a standard digital PCR procedure for cost-effective PGD of α-thalassemia in a standard IVF clinic. Copyright © 2017. Published by Elsevier B.V.

  16. Fault Detection Coverage Quantification of Automatic Test Functions of Digital I and C System in NPPs

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Lee, Seung Jun; Hur, Seop; Lee, Young Jun; Jang, Seung Cheol

    2011-01-01

    Recently, analog instrument and control (I and C) systems in nuclear power plants (NPPs) have been replaced with digital systems for safer and more efficient operations. Digital I and C systems have adopted various fault-tolerant techniques that help the system correctly and safely perform the specific required functions in spite of the presence of faults. Each fault-tolerant technique has a different inspection period from real-time monitoring to monthly testing. The range covered by each fault-tolerant technique is also different. The digital I and C system, therefore, adopts multiple barriers consisting of various fault-tolerant techniques to increase total fault detection coverage. Even though these fault-tolerant techniques are adopted to ensure and improve the safety of a system, their effects have not been properly considered yet in most PSA models. Therefore, it is necessary to develop an evaluation method that can describe these features of a digital I and C system. Several issues must be considered in the fault coverage estimation of a digital I and C system, and two of them were handled in this work. The first is to quantify the fault coverage of each fault-tolerant technique implemented in the system, and the second is to exclude the duplicated effect of fault-tolerant techniques implemented simultaneously at each level of the system's hierarchy, as a fault occurring in a system might be detected by one or more fault-tolerant techniques. For this work, fault injection experiment was used to obtain the exact relations between faults and multiple barriers of fault-tolerant techniques. This experiment was applied to a bistable processor (BP) of a reactor protection system

  17. Digital detection system of surface defects for large aperture optical elements

    International Nuclear Information System (INIS)

    Fan Yong; Chen Niannian; Gao Lingling; Jia Yuan; Wang Junbo; Cheng Xiaofeng

    2009-01-01

    Based on the light defect images against the dark background in a scattering imaging system, a digital detection system of surface defects for large aperture optical elements has been presented. In the system, the image is segmented by a multi-area self-adaptive threshold segmentation method, then a pixel labeling method based on replacing arrays is adopted to extract defect features quickly, and at last the defects are classified through back-propagation neural networks. Experiment results show that the system can achieve real-time detection and classification. (authors)

  18. Use of morphologic filters in the computerized detection of lung nodules in digital chest images

    International Nuclear Information System (INIS)

    Yoshimura, H.; Giger, M.L.; Doi, K.; Ahn, N.; MacMahon, H.

    1989-01-01

    The authors have previously described a computerized scheme for the detection of lung nodules based on a difference-image approach, which had a detection accuracy of 70% with 7--8 false positives per image. Currently, they are investigating morphologic filters for the further enhancement/suppression of nodule-signals and the removal of false-positives. Gray-level morphologic filtering is performed on clinical chest radiographs digitized with an optical drum scanner. Various shapes and sequences of erosion and dilation filters (i.e., determination of the minimum and maximum gray levels, respectively) were examined for signal enhancement and suppression for sue in the difference- image approach

  19. Prevalence of optical coherence tomography detected vitreomacular interface disorders: The Maastricht Study.

    Science.gov (United States)

    Liesenborghs, Ilona; De Clerck, Eline E B; Berendschot, Tos T J M; Goezinne, Fleur; Schram, Miranda T; Henry, Ronald M A; Stehouwer, Coen D A; Webers, Carroll A B; Schouten, Jan S A G

    2018-01-25

    To calculate the prevalence of all vitreomacular interface (VMI) disorders and stratify according to age, sex and (pre)diabetes status. The presence of VMI disorders was assessed in 2660 participants aged between 40 and 75 years from The Maastricht Study who had a gradable macular spectral-domain optical coherence tomography (SD-OCT) volume scan in at least one eye [mean 59.7 ± 8.2 years, 50.2% men, 1531 normal glucose metabolism (NGM), 401 prediabetes, 728 type 2 diabetes (DM2, oversampled)]. A stratified and multivariable logistic regression analysis was used. The prevalence of the different VMI disorders for individuals with NGM, prediabetes and DM2 was, respectively, 5.7%, 6% and 6.7% for epiretinal membranes; 6%, 9.6% and 6.8% for vitreomacular traction; 1.1%, 0.7% and 0.3% for lamellar macular holes; 0.1%, 0% and 0% for pseudoholes; 1.1%, 1.9% and 5.5% for macular cysts. None of the participants was diagnosed with a macular hole. The prevalence of epiretinal membranes, vitreomacular traction and macular cysts was higher with age (p women (p DM2 is positively associated [OR = 3.9 (95% CI 2.11-7.22, p < 0.001)] with macular cysts and negatively associated with lamellar macular holes [OR = 0.2 (95% CI 0.04-0.9, p = 0.036)] after adjustment for age and sex. The calculated prevalence of VMI disorders was 15.9%. The calculated prevalence of VMI disorders in individuals aged between 40 and 75 years is 15.9%. The prevalence depends on age, sex and glucose metabolism status for several types of VMI disorders. © 2018 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

  20. Development of a faulty reactivity detection system applying a digital H∞ estimator

    International Nuclear Information System (INIS)

    Suzuki, Katsuo; Suzudo, Tomoaki; Nabeshima, Kunihiko

    2004-01-01

    This paper concerns an application of digital optimal H ∞ estimator to the detection of faulty reactivity in real-time. The detection system, fundamentally based on the reactivity balance method, is composed of three modules, i.e. the net reactivity estimator, the feedback reactivity estimator and the reactivity balance circuit. H ∞ optimal filters are used for these two reactivity estimators, and the nonlinear neutronics are taken into consideration especially for the design of the net reactivity estimator. A series of performance test of the detection system are conducted by using numerical simulations of reactor dynamics with the insertion of a faulty reactivity for an experimental fast breeder reactor JOYO. The system detects the typical artificial reactivity insertions during a few seconds with no stationary offset and the accuracy of 0.1 cent, and is satisfactory for its practical use. (author)

  1. Detection of rib fractures in an abused infant using digital radiography: a laboratory study

    International Nuclear Information System (INIS)

    Kleinman, Paul K.; O'Connor, Brian; Nimkin, Katherine; Rayder, Shawn M.; Spevak, Melissa R.; Belanger, Patricia L.; Getty, David J.; Karellas, Andrew

    2002-01-01

    To assess the diagnostic performance of digital radiography using charge-coupled device (CCD) technology in the detection of rib fracture in infant abuse.Materials and methods. Four fractured posterior rib arcs and eight normal ribs removed at autopsy from a 10-month-old abused infant were radiographed using a CCD prototype, four clinical film-screen systems, and direct-exposure film. Each rib was viewed with these six systems in nine different projections. The resultant 648 images were assessed for probability of fracture (0-100%) by four pediatric radiologists. The calculated area under the resultant ROC curves (A z ) for the CCD was compared with those obtained with direct-exposure, high-detail, medium and fast film-screen radiographic systems. The mean A z for the CCD (0.937) fell within the range of the high-detail systems (0.934-0.940) and was significantly higher (p 20 line pairs per millimeter) the CCD performance was comparable (A z =0.944 vs. 0.937). The similar performance can be explained by the higher contrast resolution of the digital technology. This study indicates that in the ex vivo setting, digital radiology can perform comparably to high-detail film-screen imaging. The findings suggest that digital radiography has the potential to replace film-screen imaging in the evaluation of inflicted skeletal injury in infants. (orig.)

  2. A study on the artificial interproximal caries detection with the digital radiography

    International Nuclear Information System (INIS)

    Kwon, Ki Jeong; Hwang, Eui Hwan; Lee, Sang Rae

    1994-01-01

    The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit -DX compatible, video camera (VM-S8200, Hitachi Co., Japan), and color monitor (Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC (analog to digital converter) was used, and spatial resolution has 256 gray levels. The obtained results were as follows: 1. at the condition of under exposure, the radiographs were superior to the images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with the normal enamel.

  3. An ROC study detecting ability of idiopathic pulmonary fibrosis using digital radiography

    International Nuclear Information System (INIS)

    Chung, Eun Chul; Im, Jung Gi; Han, Man Chung; Kim, Jong Hyo

    1991-01-01

    One potential advantage of the digital radiography system is its ability to enhance image quality by various types of processing. Digital unsharp masking is one of the simplest and most useful forms of enhancing processes. The efficacy of unsharp masking in radiological diagnosis has not been investigated thoroughly. To evaluate the effects of unsharp masking in film-digital chest images, 3 observers were shown 150 test radiographs. These test radiographs consisted of 50 unprocessed images (25 normals and 25 patients with idiopathic pulmonary fibrosis with honey combing) and their 100 processed images by using 450 and 15-sized masks respectively. An ROC analysis of these data suggests that unsharp masking is more effective in detecting idiopathic pulmonary fibrosis than unprocessed image (ρ < 0.05), and so it may improve diagnostic accuracy for interstitial fibrosis. In addition, the smaller mask size (15) is more effective than the larger one (mask size 45) (ρ < 0.05). By using this analytic approach, an optimal parameter in digital chest radiography may be investigated in many other forms of pulmonary disease such as pulmonary nodule or mediastinal mass

  4. An ROC study detecting ability of idiopathic pulmonary fibrosis using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Eun Chul; Im, Jung Gi; Han, Man Chung; Kim, Jong Hyo [College of Medicine, Ewha Womens University, Seoul (Korea, Republic of)

    1991-03-15

    One potential advantage of the digital radiography system is its ability to enhance image quality by various types of processing. Digital unsharp masking is one of the simplest and most useful forms of enhancing processes. The efficacy of unsharp masking in radiological diagnosis has not been investigated thoroughly. To evaluate the effects of unsharp masking in film-digital chest images, 3 observers were shown 150 test radiographs. These test radiographs consisted of 50 unprocessed images (25 normals and 25 patients with idiopathic pulmonary fibrosis with honey combing) and their 100 processed images by using 450 and 15-sized masks respectively. An ROC analysis of these data suggests that unsharp masking is more effective in detecting idiopathic pulmonary fibrosis than unprocessed image ({rho} < 0.05), and so it may improve diagnostic accuracy for interstitial fibrosis. In addition, the smaller mask size (15) is more effective than the larger one (mask size 45) ({rho} < 0.05). By using this analytic approach, an optimal parameter in digital chest radiography may be investigated in many other forms of pulmonary disease such as pulmonary nodule or mediastinal mass.

  5. Comparison of detectability in step-and-shoot mode and continuous mode digital tomosynthesis systems

    Science.gov (United States)

    Lee, Changwoo; Han, Minah; Baek, Jongduk

    2017-03-01

    Digital tomosynthesis system has been widely used in chest, dental, and breast imaging. Since the digital tomosynthesis system provides volumetric images from multiple projection data, structural noise inherent in X-ray radiograph can be reduced, and thus signal detection performance is improved. Currently, tomosynthesis system uses two data acquisition modes: step-and-shoot mode and continuous mode. Several studies have been conducted to compare the system performance of two acquisition modes with respect to spatial resolution and contrast. In this work, we focus on signal detectability in step-and-shoot mode and continuous mode. For evaluation, uniform background is considered, and eight spherical objects with diameters of 0.5, 0.8, 1, 2, 3, 5, 8, 10 mm are used as signals. Projection data with and without spherical objects are acquired in step-and-shoot mode and continuous mode, respectively, and quantum noise are added. Then, noisy projection data are reconstructed by FDK algorithm. To compare the detection performance of two acquisition modes, we calculate task signal-to-noise ratio (SNR) of channelized Hotelling observer with Laguerre-Gauss channels for each spherical object. While the task-SNR values of two acquisition modes are similar for spherical objects larger than 1 mm diameter, step-and-shoot mode yields higher detectability for small signal sizes. The main reason of this behavior is that small signal is more affected by X-ray tube motion blur than large signal. Our results indicate that it is beneficial to use step-and-shoot data acquisition mode to improve the detectability of small signals (i.e., less than 1 mm diameter) in digital tomosynthesis systems.

  6. Handheld optical coherence tomography-reflectance confocal microscopy probe for detection of basal cell carcinoma and delineation of margins

    Science.gov (United States)

    Iftimia, Nicusor; Yélamos, Oriol; Chen, Chih-Shan J.; Maguluri, Gopi; Cordova, Miguel A.; Sahu, Aditi; Park, Jesung; Fox, William; Alessi-Fox, Christi; Rajadhyaksha, Milind

    2017-07-01

    We present a hand-held implementation and preliminary evaluation of a combined optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) probe for detecting and delineating the margins of basal cell carcinomas (BCCs) in human skin in vivo. A standard OCT approach (spectrometer-based) with a central wavelength of 1310 nm and 0.11 numerical aperture (NA) was combined with a standard RCM approach (830-nm wavelength and 0.9 NA) into a common path hand-held probe. Cross-sectional OCT images and enface RCM images are simultaneously displayed, allowing for three-dimensional microscopic assessment of tumor morphology in real time. Depending on the subtype and depth of the BCC tumor and surrounding skin conditions, OCT and RCM imaging are able to complement each other, the strengths of each helping overcome the limitations of the other. Four representative cases are summarized, out of the 15 investigated in a preliminary pilot study, demonstrating how OCT and RCM imaging may be synergistically combined to more accurately detect BCCs and more completely delineate margins. Our preliminary results highlight the potential benefits of combining the two technologies within a single probe to potentially guide diagnosis as well as treatment of BCCs.

  7. Automatic detection and recognition of multiple macular lesions in retinal optical coherence tomography images with multi-instance multilabel learning

    Science.gov (United States)

    Fang, Leyuan; Yang, Liumao; Li, Shutao; Rabbani, Hossein; Liu, Zhimin; Peng, Qinghua; Chen, Xiangdong

    2017-06-01

    Detection and recognition of macular lesions in optical coherence tomography (OCT) are very important for retinal diseases diagnosis and treatment. As one kind of retinal disease (e.g., diabetic retinopathy) may contain multiple lesions (e.g., edema, exudates, and microaneurysms) and eye patients may suffer from multiple retinal diseases, multiple lesions often coexist within one retinal image. Therefore, one single-lesion-based detector may not support the diagnosis of clinical eye diseases. To address this issue, we propose a multi-instance multilabel-based lesions recognition (MIML-LR) method for the simultaneous detection and recognition of multiple lesions. The proposed MIML-LR method consists of the following steps: (1) segment the regions of interest (ROIs) for different lesions, (2) compute descriptive instances (features) for each lesion region, (3) construct multilabel detectors, and (4) recognize each ROI with the detectors. The proposed MIML-LR method was tested on 823 clinically labeled OCT images with normal macular and macular with three common lesions: epiretinal membrane, edema, and drusen. For each input OCT image, our MIML-LR method can automatically identify the number of lesions and assign the class labels, achieving the average accuracy of 88.72% for the cases with multiple lesions, which better assists macular disease diagnosis and treatment.

  8. Feasibility of using optical coherence tomography to detect acute radiation-induced esophageal damage in small animal models

    Science.gov (United States)

    Jelvehgaran, Pouya; de Bruin, Daniel Martijn; Salguero, F. Javier; Borst, Gerben Roelof; Song, Ji-Ying; van Leeuwen, Ton G.; de Boer, Johannes F.; Alderliesten, Tanja; van Herk, Marcel

    2018-04-01

    Lung cancer survival is poor, and radiation therapy patients often suffer serious treatment side effects. The esophagus is particularly sensitive leading to acute radiation-induced esophageal damage (ARIED). We investigated the feasibility of optical coherence tomography (OCT) for minimally invasive imaging of the esophagus with high resolution (10 μm) to detect ARIED in mice. Thirty mice underwent cone-beam computed tomography imaging for initial setup assessment and dose planning followed by a single-dose delivery of 4.0, 10.0, 16.0, and 20.0 Gy on 5.0-mm spots, spaced 10.0 mm apart in the esophagus. They were repeatedly imaged using OCT up to three months postirradiation. We compared OCT findings with histopathology obtained three months postirradiation qualitatively and quantitatively using the contrast-to-background-noise ratio (CNR). Histopathology mostly showed inflammatory infiltration and edema at higher doses; OCT findings were in agreement with most of the histopathological reports. We were able to identify the ARIED on OCT as a change in tissue scattering and layer thickness. Our statistical analysis showed significant difference between the CNR values of healthy tissue, edema, and inflammatory infiltration. Overall, the average CNR for inflammatory infiltration and edema damages was 1.6-fold higher and 1.6-fold lower than for the healthy esophageal wall, respectively. Our results showed the potential role of OCT to detect and monitor the ARIED in mice, which may translate to humans.

  9. Feasibility of Optical Coherence Tomography (OCT for Intra-Operative Detection of Blood Flow during Gastric Tube Reconstruction

    Directory of Open Access Journals (Sweden)

    Sanne M. Jansen

    2018-04-01

    Full Text Available In this study; an OCT-based intra-operative imaging method for blood flow detection during esophagectomy with gastric tube reconstruction is investigated. Change in perfusion of the gastric tube tissue can lead to ischemia; with a high morbidity and mortality as a result. Anastomotic leakage (incidence 5–20% is one of the most severe complications after esophagectomy with gastric tube reconstruction. Optical imaging techniques provide for minimal-invasive and real-time visualization tools that can be used in intraoperative settings. By implementing an optical technique for blood flow detection during surgery; perfusion can be imaged and quantified and; if needed; perfusion can be improved by either a surgical intervention or the administration of medication. The feasibility of imaging gastric microcirculation in vivo using optical coherence tomography (OCT during surgery of patients with esophageal cancer by visualizing blood flow based on the speckle contrast from M-mode OCT images is studied. The percentage of pixels exhibiting a speckle contrast value indicative of flow was quantified to serve as an objective parameter to assess blood flow at 4 locations on the reconstructed gastric tube. Here; it was shown that OCT can be used for direct blood flow imaging during surgery and may therefore aid in improving surgical outcomes for patients.

  10. Motion-compensated optical coherence tomography using envelope-based surface detection and Kalman-based prediction

    Science.gov (United States)

    Irsch, Kristina; Lee, Soohyun; Bose, Sanjukta N.; Kang, Jin U.

    2018-02-01

    We present an optical coherence tomography (OCT) imaging system that effectively compensates unwanted axial motion with micron-scale accuracy. The OCT system is based on a swept-source (SS) engine (1060-nm center wavelength, 100-nm full-width sweeping bandwidth, and 100-kHz repetition rate), with axial and lateral resolutions of about 4.5 and 8.5 microns respectively. The SS-OCT system incorporates a distance sensing method utilizing an envelope-based surface detection algorithm. The algorithm locates the target surface from the B-scans, taking into account not just the first or highest peak but the entire signature of sequential A-scans. Subsequently, a Kalman filter is applied as predictor to make up for system latencies, before sending the calculated position information to control a linear motor, adjusting and maintaining a fixed system-target distance. To test system performance, the motioncorrection algorithm was compared to earlier, more basic peak-based surface detection methods and to performing no motion compensation. Results demonstrate increased robustness and reproducibility, particularly noticeable in multilayered tissues, while utilizing the novel technique. Implementing such motion compensation into clinical OCT systems may thus improve the reliability of objective and quantitative information that can be extracted from OCT measurements.

  11. Detection of early carious lesions using contrast enhancement with coherent light scattering (speckle imaging)

    International Nuclear Information System (INIS)

    Deana, A M; Jesus, S H C; Koshoji, N H; Bussadori, S K; Oliveira, M T

    2013-01-01

    Currently, dental caries still represent one of the chronic diseases with the highest prevalence and present in most countries. The interaction between light and teeth (absorption, scattering and fluorescence) is intrinsically connected to the constitution of the dental tissue. Decay induced mineral loss introduces a shift in the optical properties of the affected tissue; therefore, study of these properties may produce novel techniques aimed at the early diagnosis of carious lesions. Based on the optical properties of the enamel, we demonstrate the application of first-order spatial statistics in laser speckle imaging, allowing the detection of carious lesions in their early stages. A highlight of this noninvasive, non-destructive, real time and cost effective approach is that it allows a dentist to detect a lesion even in the absence of biofilm or moisture. (paper)

  12. Solution of the problem of superposing image and digital map for detection of new objects

    Science.gov (United States)

    Rizaev, I. S.; Miftakhutdinov, D. I.; Takhavova, E. G.

    2018-01-01

    The problem of superposing the map of the terrain with the image of the terrain is considered. The image of the terrain may be represented in different frequency bands. Further analysis of the results of collation the digital map with the image of the appropriate terrain is described. Also the approach to detection of differences between information represented on the digital map and information of the image of the appropriate area is offered. The algorithm for calculating the values of brightness of the converted image area on the original picture is offered. The calculation is based on using information about the navigation parameters and information according to arranged bench marks. For solving the posed problem the experiments were performed. The results of the experiments are shown in this paper. The presented algorithms are applicable to the ground complex of remote sensing data to assess differences between resulting images and accurate geopositional data. They are also suitable for detecting new objects in the image, based on the analysis of the matching the digital map and the image of corresponding locality.

  13. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  14. Estimation of Signal Coherence Threshold and Concealed Spectral Lines Applied to Detection of Turbofan Engine Combustion Noise

    Science.gov (United States)

    Miles, Jeffrey Hilton

    2010-01-01

    Combustion noise from turbofan engines has become important, as the noise from sources like the fan and jet are reduced. An aligned and un-aligned coherence technique has been developed to determine a threshold level for the coherence and thereby help to separate the coherent combustion noise source from other noise sources measured with far-field microphones. This method is compared with a statistics based coherence threshold estimation method. In addition, the un-aligned coherence procedure at the same time also reveals periodicities, spectral lines, and undamped sinusoids hidden by broadband turbofan engine noise. In calculating the coherence threshold using a statistical method, one may use either the number of independent records or a larger number corresponding to the number of overlapped records used to create the average. Using data from a turbofan engine and a simulation this paper shows that applying the Fisher z-transform to the un-aligned coherence can aid in making the proper selection of samples and produce a reasonable statistics based coherence threshold. Examples are presented showing that the underlying tonal and coherent broad band structure which is buried under random broadband noise and jet noise can be determined. The method also shows the possible presence of indirect combustion noise. Copyright 2011 Acoustical Society of America. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the Acoustical Society of America.

  15. DETECTION OF MICROCALCIFICATION IN DIGITAL MAMMOGRAMS USING ONE DIMENSIONAL WAVELET TRANSFORM

    Directory of Open Access Journals (Sweden)

    T. Balakumaran

    2010-11-01

    Full Text Available Mammography is the most efficient method for breast cancer early detection. Clusters of microcalcifications are the early sign of breast cancer and their detection is the key to improve prognosis of breast cancer. Microcalcifications appear in mammogram image as tiny localized granular points, which is often difficult to detect by naked eye because of their small size. Automatic and accurately detection of microcalcifications has received much more attention from radiologists and physician. An efficient method for automatic detection of clustered microcalcifications in digitized mammograms is the use of Computer Aided Diagnosis (CAD systems. This paper presents a one dimensional wavelet-based multiscale products scheme for microcalcification detection in mammogram images. The detection of microcalcifications were achieved by decomposing the each line of mammograms by 1D wavelet transform into different frequency sub-bands, suppressing the low-frequency subband, and finally reconstructing the mammogram from the subbands containing only significant high frequencies features. The significant features are obtained by multiscale products. Preliminary results indicate that the proposed scheme is better in suppressing the background and detecting the microcalcification clusters than any other wavelet decomposition methods.

  16. Investigation on location-dependent detectability of a small mass for digital breast tomosynthesis evaluation

    Science.gov (United States)

    Lee, Changwoo; Baek, Jongduk; Park, Subok

    2016-03-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality for improved breast cancer detection and diagnosis [1-5]. Numerous efforts have been made to find quantitative metrics associated with mammographic image quality assessment, such as the exponent β of anatomical noise power spectrum, glandularity, contrast noise ratio, etc. [6-8]. In addition, with the use of Fourier-domain detectability for a task-based assessment of DBT, a stationarity assumption on reconstructed image statistics was often made [9-11], resulting in the use of multiple regions-of-interest (ROIs) from different locations in order to increase sample size. While all these metrics provide some information on mammographic image characteristics and signal detection, the relationship between these metrics and detectability in DBT evaluation has not been fully understood. In this work, we investigated spatial-domain detectability trends and levels as a function of the number of slices Ns at three different ROI locations on the same image slice, where background statistics differ in terms of the aforementioned metrics. Detectabilities for the three ROI locations were calculated using multi-slice channelized Hotelling observers with 2D/3D Laguerre-Gauss channels. Our simulation results show that detectability levels and trends as a function of Ns vary across these three ROI locations. They also show that the exponent β, mean glandularity, and mean attenuation coefficient vary across the three ROI locations but they do not necessarily predict the ranking of detectability levels and trends across these ROI locations.

  17. Digital mammography: Mixed feature neural network with spectral entropy decision for detection of microcalcifications

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, B. [Univ. of South Florida, Tampa, FL (United States)]|[Nanjing Univ. of Posts and Telecommunications (China). Dept. of Telecommunication Engineering; Qian, W.; Clarke, L.P. [Univ. of South Florida, Tampa, FL (United States)

    1996-10-01

    A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCC`s) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman Filtering (KF) is employed to allow more efficient network training as required for evaluation of different features, input images, and related error analysis. A previously reported, wavelet-based image-enhancement method is also employed to enhance microcalcification clusters for improved detection. The relative performance of the MFNN for both the raw and enhanced images is evaluated using a common image database of 30 digitized mammograms, with 20 images containing 21 biopsy proven MCC`s and ten normal cases. The computed sensitivity (true positive (TP) detection rate) was 90.1% with an average low false positive (FP) detection of 0.71 MCCs/image for the enhanced images using a modified k-fold validation error estimation technique. The corresponding computed sensitivity for the raw images was reduced to 81.4% and with 0.59 FP`s MCCs/image. A relative comparison to an earlier neural network (NN) design, using only spatially related features, suggests the importance of the addition of spectral domain features when the raw image data are analyzed.

  18. Digital mammography: Mixed feature neural network with spectral entropy decision for detection of microcalcifications

    International Nuclear Information System (INIS)

    Zheng, B.

    1996-01-01

    A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCC's) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman Filtering (KF) is employed to allow more efficient network training as required for evaluation of different features, input images, and related error analysis. A previously reported, wavelet-based image-enhancement method is also employed to enhance microcalcification clusters for improved detection. The relative performance of the MFNN for both the raw and enhanced images is evaluated using a common image database of 30 digitized mammograms, with 20 images containing 21 biopsy proven MCC's and ten normal cases. The computed sensitivity (true positive (TP) detection rate) was 90.1% with an average low false positive (FP) detection of 0.71 MCCs/image for the enhanced images using a modified k-fold validation error estimation technique. The corresponding computed sensitivity for the raw images was reduced to 81.4% and with 0.59 FP's MCCs/image. A relative comparison to an earlier neural network (NN) design, using only spatially related features, suggests the importance of the addition of spectral domain features when the raw image data are analyzed

  19. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, Adriana Gabriela [Division of Dental Diagnostic Science, Rutgers School of Dental Medicine, Newark (United States); Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel [University of Texas Health Science Center San Antonio, San Antonio (United States); Teixeira, Fabrico B. [Dept. of Endodontics, University of Iowa, Iowa City (United States)

    2015-09-15

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  20. A fluorometric lateral flow assay for visual detection of nucleic acids using a digital camera readout.

    Science.gov (United States)

    Magiati, Maria; Sevastou, Areti; Kalogianni, Despina P

    2018-06-04

    A fluorometric lateral flow assay has been developed for the detection of nucleic acids. The fluorophores phycoerythrin (PE) and fluorescein isothiocyanate (FITC) were used as labels, while a common digital camera and a colored vinyl-sheet, acting as a cut-off optical filter, are used for fluorescence imaging. After DNA amplification by polymerase chain reaction (PCR), the biotinylated PCR product is hybridized to its complementary probe that carries a poly(dA) tail at 3΄ edge and then applied to the lateral flow strip. The hybrids are captured to the test zone of the strip by immobilized poly(dT) sequences and detected by streptavidin-fluorescein and streptavidin-phycoerythrin conjugates, through streptavidin-biotin interaction. The assay is widely applicable, simple, cost-effective, and offers a large multiplexing potential. Its performance is comparable to assays based on the use of streptavidin-gold nanoparticles conjugates. As low as 7.8 fmol of a ssDNA and 12.5 fmol of an amplified dsDNA target were detectable. Graphical abstract Schematic presentation of a fluorometric lateral flow assay based on fluorescein and phycoerythrin fluorescent labels for the detection of single-stranded (ssDNA) and double-stranded DNA (dsDNA) sequences and using a digital camera readout. SA: streptavidin, BSA: Bovine Serum Albumin, B: biotin, FITC: fluorescein isothiocyanate, PE: phycoerythrin, TZ: test zone, CZ: control zone.

  1. Trainable Cataloging for Digital Image Libraries with Applications to Volcano Detection

    Science.gov (United States)

    Burl, M. C.; Fayyad, U. M.; Perona, P.; Smyth, P.

    1995-01-01

    Users of digital image libraries are often not interested in image data per se but in derived products such as catalogs of objects of interest. Converting an image database into a usable catalog is typically carried out manually at present. For many larger image databases the purely manual approach is completely impractical. In this paper we describe the development of a trainable cataloging system: the user indicates the location of the objects of interest for a number of training images and the system learns to detect and catalog these objects in the rest of the database. In particular we describe the application of this system to the cataloging of small volcanoes in radar images of Venus. The volcano problem is of interest because of the scale (30,000 images, order of 1 million detectable volcanoes), technical difficulty (the variability of the volcanoes in appearance) and the scientific importance of the problem. The problem of uncertain or subjective ground truth is of fundamental importance in cataloging problems of this nature and is discussed in some detail. Experimental results are presented which quantify and compare the detection performance of the system relative to human detection performance. The paper concludes by discussing the limitations of the proposed system and the lessons learned of general relevance to the development of digital image libraries.

  2. Blurred digital mammography images: an analysis of technical recall and observer detection performance.

    Science.gov (United States)

    Ma, Wang Kei; Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter

    2017-03-01

    Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ 2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ 2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring.

  3. Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

    International Nuclear Information System (INIS)

    Sadaf, Arifa; Crystal, Pavel; Scaranelo, Anabel; Helbich, Thomas

    2011-01-01

    Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers.

  4. Systems and methods for selective detection and imaging in coherent Raman microscopy by spectral excitation shaping

    Science.gov (United States)

    Xie, Xiaoliang Sunney; Freudiger, Christian; Min, Wei

    2016-03-15

    A microscopy imaging system is disclosed that includes a light source system, a spectral shaper, a modulator system, an optics system, an optical detector and a processor. The light source system is for providing a first train of pulses and a second train of pulses. The spectral shaper is for spectrally modifying an optical property of at least some frequency components of the broadband range of frequency components such that the broadband range of frequency components is shaped producing a shaped first train of pulses to specifically probe a spectral feature of interest from a sample, and to reduce information from features that are not of interest from the sample. The modulator system is for modulating a property of at least one of the shaped first train of pulses and the second train of pulses at a modulation frequency. The optical detector is for detecting an integrated intensity of substantially all optical frequency components of a train of pulses of interest transmitted or reflected through the common focal volume. The processor is for detecting a modulation at the modulation frequency of the integrated intensity of substantially all of the optical frequency components of the train of pulses of interest due to the non-linear interaction of the shaped first train of pulses with the second train of pulses as modulated in the common focal volume, and for providing an output signal for a pixel of an image for the microscopy imaging system.

  5. First Demonstration of a Scintillating Xenon Bubble Chamber for Detecting Dark Matter and Coherent Elastic Neutrino-Nucleus Scattering

    Science.gov (United States)

    Baxter, D.; Chen, C. J.; Crisler, M.; Cwiok, T.; Dahl, C. E.; Grimsted, A.; Gupta, J.; Jin, M.; Puig, R.; Temples, D.; Zhang, J.

    2017-06-01

    A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is instrumented with a CCD camera for near-IR bubble imaging, a solar-blind photomultiplier tube to detect 175-nm xenon scintillation light, and a piezoelectric acoustic transducer to detect the ultrasonic emission from a growing bubble. The time of nucleation determined from the acoustic signal is used to correlate specific scintillation pulses with bubble-nucleating events. We report on data from this chamber for thermodynamic "Seitz" thresholds from 4.2 to 15.0 keV. The observed single- and multiple-bubble rates when exposed to a Cf 252 neutron source indicate that, for an 8.3-keV thermodynamic threshold, the minimum nuclear recoil energy required to nucleate a bubble is 19 ±6 keV (1 σ uncertainty). This is consistent with the observed scintillation spectrum for bubble-nucleating events. We see no evidence for bubble nucleation by gamma rays at any of the thresholds studied, setting a 90% C.L. upper limit of 6.3 ×10-7 bubbles per gamma interaction at a 4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination than in CF3 I bubble chambers, supporting the hypothesis that scintillation production suppresses bubble nucleation by electron recoils, while nuclear recoils nucleate bubbles as usual. These measurements establish the noble-liquid bubble chamber as a promising new technology for the detection of weakly interacting massive particle dark matter and coherent elastic neutrino-nucleus scattering.

  6. VCSEL Based Coherent PONs

    DEFF Research Database (Denmark)

    Jensen, Jesper Bevensee; Rodes, Roberto; Caballero Jambrina, Antonio

    2014-01-01

    We present a review of research performed in the area of coherent access technologies employing vertical cavity surface emitting lasers (VCSELs). Experimental demonstrations of optical transmission over a passive fiber link with coherent detection using VCSEL local oscillators and directly modula...

  7. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  8. A Self-embedding Robust Digital Watermarking Algorithm with Blind Detection

    Directory of Open Access Journals (Sweden)

    Gong Yunfeng

    2014-08-01

    Full Text Available In order to achieve the perfectly blind detection of robustness watermarking algorithm, a novel self-embedding robust digital watermarking algorithm with blind detection is proposed in this paper. Firstly the original image is divided to not overlap image blocks and then decomposable coefficients are obtained by lifting-based wavelet transform in every image blocks. Secondly the low-frequency coefficients of block images are selected and then approximately represented as a product of a base matrix and a coefficient matrix using NMF. Then the feature vector represent original image is obtained by quantizing coefficient matrix, and finally the adaptive quantization of the robustness watermark is embedded in the low-frequency coefficients of LWT. Experimental results show that the scheme is robust against common signal processing attacks, meanwhile perfect blind detection is achieve.

  9. Robust Nucleus/Cell Detection and Segmentation in Digital Pathology and Microscopy Images: A Comprehensive Review.

    Science.gov (United States)

    Xing, Fuyong; Yang, Lin

    2016-01-01

    Digital pathology and microscopy image analysis is widely used for comprehensive studies of cell morphology or tissue structure. Manual assessment is labor intensive and prone to interobserver variations. Computer-aided methods, which can significantly improve the objectivity and reproducibility, have attracted a great deal of interest in recent literature. Among the pipeline of building a computer-aided diagnosis system, nucleus or cell detection and segmentation play a very important role to describe the molecular morphological information. In the past few decades, many efforts have been devoted to automated nucleus/cell detection and segmentation. In this review, we provide a comprehensive summary of the recent state-of-the-art nucleus/cell segmentation approaches on different types of microscopy images including bright-field, phase-contrast, differential interference contrast, fluorescence, and electron microscopies. In addition, we discuss the challenges for the current methods and the potential future work of nucleus/cell detection and segmentation.

  10. DEWA: A Multiaspect Approach for Multiple Face Detection in Complex Scene Digital Image

    Directory of Open Access Journals (Sweden)

    Setiawan Hadi

    2013-09-01

    Full Text Available A new approach for detecting faces in a digital image with unconstrained background has been developed. The approach is composed of three phases: segmentation phase, filtering phase and localization phase. In the segmentation phase, we utilized both training and non-training methods, which are implemented in user selectable color space. In the filtering phase, Minkowski addition-based objects removal has been used for image cleaning. In the last phase, an image processing method and a data mining method are employed for grouping and localizing objects, combined with geometric-based image analysis. Several experiments have been conducted using our special face database that consists of simple objects and complex objects. The experiment results demonstrated that the detection accuracy is around 90% and the detection speed is less than 1 second in average.

  11. Gradual cut detection using low-level vision for digital video

    Science.gov (United States)

    Lee, Jae-Hyun; Choi, Yeun-Sung; Jang, Ok-bae

    1996-09-01

    Digital video computing and organization is one of the important issues in multimedia system, signal compression, or database. Video should be segmented into shots to be used for identification and indexing. This approach requires a suitable method to automatically locate cut points in order to separate shot in a video. Automatic cut detection to isolate shots in a video has received considerable attention due to many practical applications; our video database, browsing, authoring system, retrieval and movie. Previous studies are based on a set of difference mechanisms and they measured the content changes between video frames. But they could not detect more special effects which include dissolve, wipe, fade-in, fade-out, and structured flashing. In this paper, a new cut detection method for gradual transition based on computer vision techniques is proposed. And then, experimental results applied to commercial video are presented and evaluated.

  12. Automatic Detection of Microcalcifications in a Digital Mammography Using Artificial Intelligence Techniques

    Directory of Open Access Journals (Sweden)

    Carlos A. Madrigal-González

    2013-11-01

    Full Text Available Breast cancer is one of the cancers that has a higher mortality rate among women and early detection increases the possibilities of cure, so its early detection is one of the best treatments for this serious disease. Microcalcifications are a type of lesion in the breast and its presence is highly correlated with the presence of cancer. In this paper we present a method for automatic detection of microcalcifications using digital image processing using a Gaussian filtering approach, which can enhance the contrast between microcalcifications and normal tissue present in a mammography, then apply a local thresholding algorithm witch allow the identification of suspicious microcalcifications. The classifier used to determine the degree of benign or malignant microcalcifications is the K-Nearest Neighbours (KNN and the validation of the results was done using ROC curves.

  13. Automated detection of microcalcification clusters in digital mammograms based on wavelet domain hidden Markov tree modeling

    International Nuclear Information System (INIS)

    Regentova, E.; Zhang, L.; Veni, G.; Zheng, J.

    2007-01-01

    A system is designed for detecting microcalcification clusters (MCC) in digital mammograms. The system is intended for computer-aided diagnostic prompting. Further discrimination of MCC as benign or malignant is assumed to be performed by radiologists. Processing of mammograms is based on the statistical modeling by means of wavelet domain hidden markov trees (WHMT). Segmentation is performed by the weighted likelihood evaluation followed by the classification based on spatial filters for a single microcalcification (MC) and a cluster of MC detection. The analysis is carried out on FROC curves for 40 mammograms from the mini-MIAS database and for 100 mammograms with 50 cancerous and 50 benign cases from DDSM database. The designed system is capable to detect 100% of true positive cases in these sets. The rate of false positives is 2.9 per case for mini-MIAS dataset; and 0.01 for the DDSM images. (orig.)

  14. Multiplexed wavelet transform technique for detection of microcalcification in digitized mammograms.

    Science.gov (United States)

    Mini, M G; Devassia, V P; Thomas, Tessamma

    2004-12-01

    Wavelet transform (WT) is a potential tool for the detection of microcalcifications, an early sign of breast cancer. This article describes the implementation and evaluates the performance of two novel WT-based schemes for the automatic detection of clustered microcalcifications in digitized mammograms. Employing a one-dimensional WT technique that utilizes the pseudo-periodicity property of image sequences, the proposed algorithms achieve high detection efficiency and low processing memory requirements. The detection is achieved from the parent-child relationship between the zero-crossings [Marr-Hildreth (M-H) detector] /local extrema (Canny detector) of the WT coefficients at different levels of decomposition. The detected pixels are weighted before the inverse transform is computed, and they are segmented by simple global gray level thresholding. Both detectors produce 95% detection sensitivity, even though there are more false positives for the M-H detector. The M-H detector preserves the shape information and provides better detection sensitivity for mammograms containing widely distributed calcifications.

  15. Living in a digital world: features and applications of FPGA in photon detection

    Science.gov (United States)

    Arnesano, Cosimo

    signal processing in a digital fashion avoiding RF emission and it is extremely inexpensive. This development is the result of a systematic study carried on a previous design known as the FLIMBox developed as part of a thesis of another graduate student. The extensive work done in maximizing the performance of the original FLIMBox led us to develop a new hardware solution with exciting and promising results and potential that were not possible in the previous hardware realization, where the signal harmonic content was limited by the FPGA technology. The new design permits acquisition of a much larger harmonic content of the sample response when it is excited with a pulsed light source in one single measurement using the digital mixing principle that was developed in the original design. Furthermore, we used the parallel digital FD principle to perform tissue imaging through Diffuse Optical Spectroscopy (DOS) measurements. We integrated the FLIMBox in a new system that uses a supercontinuum white laser with high brightness as a single light source and photomultipliers with large detection area, both allowing a high penetration depth with extremely low power at the sample. The parallel acquisition, achieved by using the FlimBox, decreases the time required for standard serial systems that scan through all modulation frequencies. Furthermore, the all-digital acquisition avoids analog noise, removes the analog mixer of the conventional frequency domain approach, and it does not generate radio-frequencies, normally present in current analog systems. We are able to obtain a very sensitive acquisition due to the high signal to noise ratio (S/N). The successful results obtained by utilizing digital technology in photon acquisition and processing, prompted us to extend the use of FPGA to other applications, such as phosphorescence detection. Using the FPGA concept we proposed possible solutions to outstanding problems with the current technology. In this thesis I discuss new

  16. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  17. Hough transform for clustered microcalcifications detection in full-field digital mammograms

    Science.gov (United States)

    Fanizzi, A.; Basile, T. M. A.; Losurdo, L.; Amoroso, N.; Bellotti, R.; Bottigli, U.; Dentamaro, R.; Didonna, V.; Fausto, A.; Massafra, R.; Moschetta, M.; Tamborra, P.; Tangaro, S.; La Forgia, D.

    2017-09-01

    Many screening programs use mammography as principal diagnostic tool for detecting breast cancer at a very early stage. Despite the efficacy of the mammograms in highlighting breast diseases, the detection of some lesions is still doubtless for radiologists. In particular, the extremely minute and elongated salt-like particles of microcalcifications are sometimes no larger than 0.1 mm and represent approximately half of all cancer detected by means of mammograms. Hence the need for automatic tools able to support radiologists in their work. Here, we propose a computer assisted diagnostic tool to support radiologists in identifying microcalcifications in full (native) digital mammographic images. The proposed CAD system consists of a pre-processing step, that improves contrast and reduces noise by applying Sobel edge detection algorithm and Gaussian filter, followed by a microcalcification detection step performed by exploiting the circular Hough transform. The procedure performance was tested on 200 images coming from the Breast Cancer Digital Repository (BCDR), a publicly available database. The automatically detected clusters of microcalcifications were evaluated by skilled radiologists which asses the validity of the correctly identified regions of interest as well as the system error in case of missed clustered microcalcifications. The system performance was evaluated in terms of Sensitivity and False Positives per images (FPi) rate resulting comparable to the state-of-art approaches. The proposed model was able to accurately predict the microcalcification clusters obtaining performances (sensibility = 91.78% and FPi rate = 3.99) which favorably compare to other state-of-the-art approaches.

  18. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    International Nuclear Information System (INIS)

    Kocasarac, Husniye Demirturk; Celenk, Peruze

    2017-01-01

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images

  19. Simulation study on detection performance of eye-safe coherent Doppler wind lidar operating near 1.6 μm

    Science.gov (United States)

    Ma, Han; Wang, Qing; Na, Quanxin; Gao, Mingwei

    2018-01-01

    Coherent Doppler wind lidars (CDWL) are widely used in aerospace, atmospheric monitoring and other fields. The parameters of laser source such as the wavelength, pulse energy, pulse duration and pulse repetition rate (PRR) have significant influences on the detection performance of wind lidar. We established a simulation model which takes into account the effects of atmospheric transmission, backscatter, atmospheric turbulence and parameters of laser source. The maximum detection range is also calculated under the condition that the velocity estimation accuracy is 0.1 m/s by using this model. We analyzed the differences of the detection performance between two operation systems, which show the high pulse energy-low pulse repetition rate (HPE-LPRR) and low pulse energy-high repetition rate (LPE-HPRR), respectively. We proved our simulation model reliable by using the parameters of two commercial lidar products. This research has important theoretical and practical values for the design of eye-safe coherent Doppler wind lidar.

  20. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

    Science.gov (United States)

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-05-01

    To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm(3), ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.

  1. An autonomous surface discontinuity detection and quantification method by digital image correlation and phase congruency

    Science.gov (United States)

    Cinar, A. F.; Barhli, S. M.; Hollis, D.; Flansbjer, M.; Tomlinson, R. A.; Marrow, T. J.; Mostafavi, M.

    2017-09-01

    Digital image correlation has been routinely used to measure full-field displacements in many areas of solid mechanics, including fracture mechanics. Accurate segmentation of the crack path is needed to study its interaction with the microstructure and stress fields, and studies of crack behaviour, such as the effect of closure or residual stress in fatigue, require data on its opening displacement. Such information can be obtained from any digital image correlation analysis of cracked components, but it collection by manual methods is quite onerous, particularly for massive amounts of data. We introduce the novel application of Phase Congruency to detect and quantify cracks and their opening. Unlike other crack detection techniques, Phase Congruency does not rely on adjustable threshold values that require user interaction, and so allows large datasets to be treated autonomously. The accuracy of the Phase Congruency based algorithm in detecting cracks is evaluated and compared with conventional methods such as Heaviside function fitting. As Phase Congruency is a displacement-based method, it does not suffer from the noise intensification to which gradient-based methods (e.g. strain thresholding) are susceptible. Its application is demonstrated to experimental data for cracks in quasi-brittle (Granitic rock) and ductile (Aluminium alloy) materials.

  2. Mass detection in digital breast tomosynthesis data using convolutional neural networks and multiple instance learning.

    Science.gov (United States)

    Yousefi, Mina; Krzyżak, Adam; Suen, Ching Y

    2018-05-01

    Digital breast tomosynthesis (DBT) was developed in the field of breast cancer screening as a new tomographic technique to minimize the limitations of conventional digital mammography breast screening methods. A computer-aided detection (CAD) framework for mass detection in DBT has been developed and is described in this paper. The proposed framework operates on a set of two-dimensional (2D) slices. With plane-to-plane analysis on corresponding 2D slices from each DBT, it automatically learns complex patterns of 2D slices through a deep convolutional neural network (DCNN). It then applies multiple instance learning (MIL) with a randomized trees approach to classify DBT images based on extracted information from 2D slices. This CAD framework was developed and evaluated using 5040 2D image slices derived from 87 DBT volumes. The empirical results demonstrate that this proposed CAD framework achieves much better performance than CAD systems that use hand-crafted features and deep cardinality-restricted Bolzmann machines to detect masses in DBTs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Optical coherence tomography detection of characteristic retinal nerve fiber layer thinning in nasal hypoplasia of the optic disc.

    Science.gov (United States)

    Haruta, M; Kodama, R; Yamakawa, R

    2017-12-01

    PurposeTo determine the clinical usefulness of optical coherence tomography (OCT) for detecting thinning of the retinal nerve fiber layer (RNFL) in eyes with nasal hypoplasia of the optic discs (NHOD).Patients and methodsThe medical records of five patients (eight eyes) with NHOD were reviewed. The ratio of the disc-macula distance to the disc diameter (DM/DD) and the disc ovality ratio of the minimal to maximal DD were assessed using fundus photographs. The RNFL thicknesses of the temporal, superior, nasal, and inferior quadrants were evaluated using OCT quadrant maps.ResultsAll eight eyes had temporal visual field defects that respected the vertical meridians that needed to be differentiated from those related to chiasmal compression. The mean DM/DD ratio was 3.1 and the mean disc ovality ratio was 0.81. The mean RNFL thicknesses of the temporal, superior, nasal, and inferior quadrants were 90.3, 103.1, 34.8, and 112.8 microns, respectively.ConclusionSmall optic discs and tilted discs might be associated with NHOD. Measurement of the RNFL thickness around the optic disc using OCT scans clearly visualized the characteristic RNFL thinning of the nasal quadrants corresponding to the temporal sector visual field defects in eyes with NHOD. OCT confirmed the presence of NHOD and might differentiate eyes with NHOD from those with chiasmal compression.

  4. SAR image effects on coherence and coherence estimation.

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Douglas Lloyd

    2014-01-01

    Radar coherence is an important concept for imaging radar systems such as synthetic aperture radar (SAR). This document quantifies some of the effects in SAR which modify the coherence. Although these effects can disrupt the coherence within a single SAR image, this report will focus on the coherence between separate images, such as for coherent change detection (CCD) processing. There have been other presentations on aspects of this material in the past. The intent of this report is to bring various issues that affect the coherence together in a single report to support radar engineers in making decisions about these matters.

  5. Detection of interference phase by digital computation of quadrature signals in homodyne laser interferometry

    Czech Academy of Sciences Publication Activity Database

    Řeřucha, Šimon; Buchta, Zdeněk; Šarbort, Martin; Lazar, Josef; Číp, Ondřej

    2012-01-01

    Roč. 12, č. 10 (2012), s. 14095-14112 ISSN 1424-8220 R&D Projects: GA ČR GAP102/10/1813; GA MŠk ED0017/01/01; GA MPO FR-TI2/705; GA MPO FR-TI1/241; GA MŠk EE2.3.30.0054 Institutional support: RVO:68081731 Keywords : digital signal processing * homodyne detection * laser interferometry * optical metrology Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.953, year: 2012

  6. Automated Detection and Classification of Corneal Haze Using Optical Coherence Tomography in Patients With Keratoconus After Cross-Linking.

    Science.gov (United States)

    Dhaini, Ahmad R; Abdul Fattah, Maamoun; El-Oud, Sara Maria; Awwad, Shady T

    2018-03-13

    To evaluate a proposed technology for offering objective grading and mapping of corneal haze as detected by corneal spectral domain optical coherence tomography after corneal cross-linking. This was a retrospective study to evaluate corneal optical coherence tomography images performed on 44 eyes of 44 patients who underwent corneal cross-linking between January 2014 and May 2015, at the American University of Beirut Medical Center. Overall average brightness of the cornea was markedly increased from 43.4% (±6.0) at baseline to 50.2% (±4.4) at 1 month, 47.9% (±4.4) at 3 months, and 46.4% (±5.7) at 6 months with P <0.001, <0.001, and 0.005, respectively. In the anterior stroma, the average brightness significantly increased at 1, 3, and 6 months with values of 54.8% (±3.9), 52.5% (±5.2), and 49.7% (±6.9) with P <0.001, <0.001, and 0.003, respectively. In the mid stroma, the change was clinically significant at 1 and 3 months, whereas in the posterior stroma, it was only significant at 1 month compared with baseline (P = 0.003). Overall, haze was mostly present at 1 month after surgery in all regions, especially in the anterior (32.1%; ±19.2) and mid stromal regions (9.1%; ±18.8), P <0.001 and 0.001, respectively. In contrast, haze in the posterior stromal region peaks at 3 and 6 months after surgery. Anterior stromal haze was the greatest in intensity and area and it was present for a longer time span than mid and posterior stromal haze. At 12 months, the anterior stroma had still more haze intensity than preoperatively. This image-based software can provide objective and valuable quantitative measurements of corneal haze, which may impact clinical decision-making after different corneal surgeries.

  7. Automated detection of exudative age-related macular degeneration in spectral domain optical coherence tomography using deep learning.

    Science.gov (United States)

    Treder, Maximilian; Lauermann, Jost Lennart; Eter, Nicole

    2018-02-01

    Our purpose was to use deep learning for the automated detection of age-related macular degeneration (AMD) in spectral domain optical coherence tomography (SD-OCT). A total of 1112 cross-section SD-OCT images of patients with exudative AMD and a healthy control group were used for this study. In the first step, an open-source multi-layer deep convolutional neural network (DCNN), which was pretrained with 1.2 million images from ImageNet, was trained and validated with 1012 cross-section SD-OCT scans (AMD: 701; healthy: 311). During this procedure training accuracy, validation accuracy and cross-entropy were computed. The open-source deep learning framework TensorFlow™ (Google Inc., Mountain View, CA, USA) was used to accelerate the deep learning process. In the last step, a created DCNN classifier, using the information of the above mentioned deep learning process, was tested in detecting 100 untrained cross-section SD-OCT images (AMD: 50; healthy: 50). Therefore, an AMD testing score was computed: 0.98 or higher was presumed for AMD. After an iteration of 500 training steps, the training accuracy and validation accuracies were 100%, and the cross-entropy was 0.005. The average AMD scores were 0.997 ± 0.003 in the AMD testing group and 0.9203 ± 0.085 in the healthy comparison group. The difference between the two groups was highly significant (p deep learning-based approach using TensorFlow™, it is possible to detect AMD in SD-OCT with high sensitivity and specificity. With more image data, an expansion of this classifier for other macular diseases or further details in AMD is possible, suggesting an application for this model as a support in clinical decisions. Another possible future application would involve the individual prediction of the progress and success of therapy for different diseases by automatically detecting hidden image information.

  8. Digital camera image analysis of faeces in detection of cholestatic jaundice in infants.

    Science.gov (United States)

    Parinyanut, Parinya; Bandisak, Tai; Chiengkriwate, Piyawan; Tanthanuch, Sawit; Sangkhathat, Surasak

    2016-01-01

    Stool colour assessment is a screening method for biliary tract obstruction in infants. This study is aimed to be a proof of concept work of digital photograph image analysis of stool colour compared to colour grading by a colour card, and the stool bilirubin level test. The total bilirubin (TB) level contents in stool samples from 17 infants aged less than 1 year, seven with confirmed cholestatic jaundice and ten healthy subjects was measured, and outcome correlated with the physical colour of the stool. The seven infants with cholestasis included 6 cases of biliary atresia and 1 case of pancreatic mass. All pre-operative stool samples in these cases were indicated as grade 1 on the stool card (stool colour in healthy infants ranges from 4 to 6). The average stool TB in the pale stool group was 43.07 μg/g compared to 101.78 μg/g in the non-pale stool group. Of the 3 colour channels assessed in the digital photographs, the blue and green light were best able to discriminate accurately between the pre-operative stool samples from infants with cholestasis and the samples from the healthy controls. With red, green, and blue (RGB) image analysis using wave level as the ANN input, the system predicts the stool TB with a relationship coefficient of 0.96, compared to 0.61 when stool colour card grading was used. Input from digital camera images of stool had a higher predictive capability compared to the standard stool colour card, indicating using digital photographs may be a useful tool for detection of cholestasis in infants.

  9. Detection of rib fractures in an abused infant using digital radiography: a laboratory study

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, Paul K. [Department of Radiology, UMASS Memorial Health Care, 55 Lake Avenue North, Worcester, MA 01655 (United States); O' Connor, Brian; Nimkin, Katherine [Department of Pediatric Radiology, New England Medical Center, 750 Washington Street, Boston, MA 02111 (United States); Rayder, Shawn M. [Department of Radiology, Cape Cod Hospital, 12 Park Street, Hyannis, MA 02601-5203 (United States); Spevak, Melissa R. [Department of Radiology, Johns Hopkins Hospital, 600 N. Wolfe Street, Baltimore, MD 21287 (United States); Belanger, Patricia L. [University of Massachusetts, Amherst, MA 01003 (United States); Getty, David J. [BBNT Solutions LLC, 10 Moulton Street, Cambridge, MA 02138 (United States); Karellas, Andrew [Department of Radiology, University of Mass. Medical School, Lake Avenue North, Worcester, MA 01655 (United States)

    2002-12-01

    To assess the diagnostic performance of digital radiography using charge-coupled device (CCD) technology in the detection of rib fracture in infant abuse.Materials and methods. Four fractured posterior rib arcs and eight normal ribs removed at autopsy from a 10-month-old abused infant were radiographed using a CCD prototype, four clinical film-screen systems, and direct-exposure film. Each rib was viewed with these six systems in nine different projections. The resultant 648 images were assessed for probability of fracture (0-100%) by four pediatric radiologists. The calculated area under the resultant ROC curves (A{sub z}) for the CCD was compared with those obtained with direct-exposure, high-detail, medium and fast film-screen radiographic systems. The mean A{sub z} for the CCD (0.937) fell within the range of the high-detail systems (0.934-0.940) and was significantly higher (p<0.05) than the medium and fast system (0.861 and 0.858, respectively). Despite a lower spatial resolution than direct-exposure film (7 line pairs per millimeter vs. >20 line pairs per millimeter) the CCD performance was comparable (A{sub z}=0.944 vs. 0.937). The similar performance can be explained by the higher contrast resolution of the digital technology. This study indicates that in the ex vivo setting, digital radiology can perform comparably to high-detail film-screen imaging. The findings suggest that digital radiography has the potential to replace film-screen imaging in the evaluation of inflicted skeletal injury in infants. (orig.)

  10. Digital camera image analysis of faeces in detection of cholestatic jaundice in infants

    Directory of Open Access Journals (Sweden)

    Parinya Parinyanut

    2016-01-01

    Full Text Available Background: Stool colour assessment is a screening method for biliary tract obstruction in infants. This study is aimed to be a proof of concept work of digital photograph image analysis of stool colour compared to colour grading by a colour card, and the stool bilirubin level test. Materials and Methods: The total bilirubin (TB level contents in stool samples from 17 infants aged less than 1 year, seven with confirmed cholestatic jaundice and ten healthy subjects was measured, and outcome correlated with the physical colour of the stool. Results: The seven infants with cholestasis included 6 cases of biliary atresia and 1 case of pancreatic mass. All pre-operative stool samples in these cases were indicated as grade 1 on the stool card (stool colour in healthy infants ranges from 4 to 6. The average stool TB in the pale stool group was 43.07 μg/g compared to 101.78 μg/g in the non-pale stool group. Of the 3 colour channels assessed in the digital photographs, the blue and green light were best able to discriminate accurately between the pre-operative stool samples from infants with cholestasis and the samples from the healthy controls. With red, green, and blue (RGB image analysis using wave level as the ANN input, the system predicts the stool TB with a relationship coefficient of 0.96, compared to 0.61 when stool colour card grading was used. Conclusion: Input from digital camera images of stool had a higher predictive capability compared to the standard stool colour card, indicating using digital photographs may be a useful tool for detection of cholestasis in infants.

  11. Detection and localization of copy-paste forgeries in digital videos.

    Science.gov (United States)

    Singh, Raahat Devender; Aggarwal, Naveen

    2017-12-01

    Amidst the continual march of technology, we find ourselves relying on digital videos to proffer visual evidence in several highly sensitive areas such as journalism, politics, civil and criminal litigation, and military and intelligence operations. However, despite being an indispensable source of information with high evidentiary value, digital videos are also extremely vulnerable to conscious manipulations. Therefore, in a situation where dependence on video evidence is unavoidable, it becomes crucial to authenticate the contents of this evidence before accepting them as an accurate depiction of reality. Digital videos can suffer from several kinds of manipulations, but perhaps, one of the most consequential forgeries is copy-paste forgery, which involves insertion/removal of objects into/from video frames. Copy-paste forgeries alter the information presented by the video scene, which has a direct effect on our basic understanding of what that scene represents, and so, from a forensic standpoint, the challenge of detecting such forgeries is especially significant. In this paper, we propose a sensor pattern noise based copy-paste detection scheme, which is an improved and forensically stronger version of an existing noise-residue based technique. We also study a demosaicing artifact based image forensic scheme to estimate the extent of its viability in the domain of video forensics. Furthermore, we suggest a simplistic clustering technique for the detection of copy-paste forgeries, and determine if it possess the capabilities desired of a viable and efficacious video forensic scheme. Finally, we validate these schemes on a set of realistically tampered MJPEG, MPEG-2, MPEG-4, and H.264/AVC encoded videos in a diverse experimental set-up by varying the strength of post-production re-compressions and transcodings, bitrates, and sizes of the tampered regions. Such an experimental set-up is representative of a neutral testing platform and simulates a real

  12. Digital-to-analog device for continuous detection of neutron damping decrement in logging

    International Nuclear Information System (INIS)

    Sokolov, Yu.I.; Zinchenko, A.I.; Rudenko, Eh.L.

    1976-01-01

    Algorithms are analyzed for a continuous detection of the damping decrement (DD) of the thermal neutron density in time, characterizing absorptive and diffusion properties of a bed; an an automated measuring device has been developed. The design of a digital calculator involving reguired mathematical and logical operations in the DD measurement by the specified algorithms necessitated the use of a system of elements with a diode-transistor RC logic. Following laboratory tests the mock-up of the calculator was subjected to borehole tests as part of the pulsed neutron logging apparatus of the IGN-4 type. A continuous detection of the DD reciprocal with a parallel recording of the differential and integral curves of pulsed neutron-neutron logging has been performed. The borehole tests revealed the efficiency of the new device and the possibility of its use together with the apparatus of the IGN-4 type

  13. A study on detection of internal defects of pressure vessel by digital shearography

    International Nuclear Information System (INIS)

    Kang, Young Jun; Park, Sung Tae; Lee, Hae Moo; Nam, Seung Hun

    1999-01-01

    Pipelines in power plants, nuclear facilities and chemical industries are often affected by corrosion effects. The inspection of internal defects of these pipelines is important to guarantee safe operational condition. Conventional NDT methods have been taken relatively much time, money, and manpower because of performing as the method of contact with objects to be inspected. Digital shearography is a laser-based optical method which allows full-field observation of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time measurement. Therefore it is a good method to use for detecting internal defects. In this paper, the experiment was performed with some pressure vessels which has different internal cracks. We detected internal cracks of the pressure vessels at a real time and evaluated qualitatively these results. We also performed qualitative measurement of shearo fringe by using phase shifting method.

  14. Digital Image Forgery Detection Using JPEG Features and Local Noise Discrepancies

    Directory of Open Access Journals (Sweden)

    Bo Liu

    2014-01-01

    Full Text Available Wide availability of image processing software makes counterfeiting become an easy and low-cost way to distort or conceal facts. Driven by great needs for valid forensic technique, many methods have been proposed to expose such forgeries. In this paper, we proposed an integrated algorithm which was able to detect two commonly used fraud practices: copy-move and splicing forgery in digital picture. To achieve this target, a special descriptor for each block was created combining the feature from JPEG block artificial grid with that from noise estimation. And forehand image quality assessment procedure reconciled these different features by setting proper weights. Experimental results showed that, compared to existing algorithms, our proposed method is effective on detecting both copy-move and splicing forgery regardless of JPEG compression ratio of the input image.

  15. Method and apparatus for clockless analog-to-digital conversion and peak detection

    Science.gov (United States)

    DeGeronimo, Gianluigi

    2007-03-06

    An apparatus and method for analog-to-digital conversion and peak detection includes at least one stage, which includes a first switch, second switch, current source or capacitor, and discriminator. The discriminator changes state in response to a current or charge associated with the input signal exceeding a threshold, thereby indicating whether the current or charge associated with the input signal is greater than the threshold. The input signal includes a peak or a charge, and the converter includes a peak or charge detect mode in which a state of the switch is retained in response to a decrease in the current or charge associated with the input signal. The state of the switch represents at least a portion of a value of the peak or of the charge.

  16. Automatic defect detection in video archives: application to Montreux Jazz Festival digital archives

    Science.gov (United States)

    Hanhart, Philippe; Rerabek, Martin; Ivanov, Ivan; Dufaux, Alain; Jones, Caryl; Delidais, Alexandre; Ebrahimi, Touradj

    2013-09-01

    Archival of audio-visual databases has become an important discipline in multimedia. Various defects are typ- ically present in such archives. Among those, one can mention recording related defects such as interference between audio and video signals, optical related artifacts, recording and play out artifacts such as horizontal lines, and dropouts, as well as those due to digitization such as diagonal lines. An automatic or semi-automatic detection to identify such defects is useful, especially for large databases. In this paper, we propose two auto- matic algorithms for detection of horizontal and diagonal lines, as well as dropouts that are among the most typical artifacts encountered. We then evaluate the performance of these algorithms by making use of ground truth scores obtained by human subjects.

  17. An effective detection algorithm for region duplication forgery in digital images

    Science.gov (United States)

    Yavuz, Fatih; Bal, Abdullah; Cukur, Huseyin

    2016-04-01

    Powerful image editing tools are very common and easy to use these days. This situation may cause some forgeries by adding or removing some information on the digital images. In order to detect these types of forgeries such as region duplication, we present an effective algorithm based on fixed-size block computation and discrete wavelet transform (DWT). In this approach, the original image is divided into fixed-size blocks, and then wavelet transform is applied for dimension reduction. Each block is processed by Fourier Transform and represented by circle regions. Four features are extracted from each block. Finally, the feature vectors are lexicographically sorted, and duplicated image blocks are detected according to comparison metric results. The experimental results show that the proposed algorithm presents computational efficiency due to fixed-size circle block architecture.

  18. Nodule detection in digital chest radiography: Summary of the radius chest trial

    International Nuclear Information System (INIS)

    Haakansson, M.; Baath, M.; Boerjesson, S.; Kheddache, S.; Grahn, A.; Ruschin, M.; Tingberg, A.; Mattson, S.; Maansson, L. G.

    2005-01-01

    As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging' - governed by the Radiological Imaging Unification Strategies (RADIUS) Group - a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule. (authors)

  19. Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Lell, M.; Boehner, C.; Bautz, W.A.; Mertelmeier, T.

    2006-01-01

    Purpose: To compare the sensitivity of conventional two-dimensional (2D) projection imaging with tomosynthesis with respect to the detectability of mammographic phantom lesions. Materials and Methods: Using a breast tomosynthesis prototype based on a commercial FFDM system (Siemens MAMMOMAT Novation DR ), but modified for a wide angle tube motion and equipped with a fast read-out amorphous selenium detector, we acquired standard 2D images and tomosynthesis series of projection views. We used the Wisconsin mammographic random phantom, model RMI 152A. The anode filter combinations Mo/Mo and W/Rh at two different doses were used as typical radiographic techniques. Slice images through the phantom parallel to the detector were reconstructed with a distance of 1 mm employing a filtered back-projection algorithm. The image data sets were read by five radiologists and evaluated with respect to the detectability of the phantom details. Results: For all studied radiographic techniques, the detection rate in the tomosynthesis mode was 100%, i.e. 75 true positive findings out of 75 possible hits. In contrast, the conventional projection mode yielded a detection rate between 80 and 93% (corresponding to 60 and 70 detected details) depending on the dose and X-ray spectrum. Conclusion: Tomosynthesis has the potential to increase the sensitivity of digital mammography. Overlapping structures from out-of-plane tissue can be removed in the tomosynthesis reconstruction process, thereby enhancing the diagnostic accuracy. (orig.)

  20. An online detection system for aggregate sizes and shapes based on digital image processing

    Science.gov (United States)

    Yang, Jianhong; Chen, Sijia

    2017-02-01

    Traditional aggregate size measuring methods are time-consuming, taxing, and do not deliver online measurements. A new online detection system for determining aggregate size and shape based on a digital camera with a charge-coupled device, and subsequent digital image processing, have been developed to overcome these problems. The system captures images of aggregates while falling and flat lying. Using these data, the particle size and shape distribution can be obtained in real time. Here, we calibrate this method using standard globules. Our experiments show that the maximum particle size distribution error was only 3 wt%, while the maximum particle shape distribution error was only 2 wt% for data derived from falling aggregates, having good dispersion. In contrast, the data for flat-lying aggregates had a maximum particle size distribution error of 12 wt%, and a maximum particle shape distribution error of 10 wt%; their accuracy was clearly lower than for falling aggregates. However, they performed well for single-graded aggregates, and did not require a dispersion device. Our system is low-cost and easy to install. It can successfully achieve online detection of aggregate size and shape with good reliability, and it has great potential for aggregate quality assurance.

  1. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  2. Modelling the imaging performance and low contrast detectability in digital mammography

    International Nuclear Information System (INIS)

    Spyropoulou, V; Kalyvas, N; Gaitanis, A; Michail, C; Panayiotakis, G; Kandarakis, I

    2009-01-01

    A digital x-ray mammography is a modern method for the early detection of breast cancer. The quality of a mammography image depends on various factors, the detector structure and performance being of primary importance. The aim of this work was to develop an analytical model simulating the imaging performance of a new commercially available digital mammography detector. This was achieved within the framework of the linear cascaded systems (LCS) theory. System analysis has allowed the estimation of important image quality metrics such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS) and the Detective Quantum Efficiency (DQE). The detector was an indirect detection system consisting of a large area, 100μm thick, CsI:TI scintillator coupled to an active matrix array of amorphous silicon (a-Si:H) photodiodes combined with thin film transistors (TFT). Pixel size was 100μm, while the active pixel dimension was 70μm. MTF and DQE data were calculated for air kerma conditions of 25, 53, 67 μGy using a 28 kVp Mo-Mo x-ray spectrum. The theoretical results were compared with published experimental data. The deviation between the theoretical and experimental MTF curves was less than 4%, while the DQE differences were found at an acceptable level. The model was also used to estimate system's capability to detect low contrast objects in the breast. It was estimated that, in the breast gland, low contrast structures larger than 1.4mm can be adequately identified by the above system.

  3. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    Science.gov (United States)

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (pphotographs (pphotographs (p>0.05). All measurements were correlated (Spearman pphotographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  4. Re-configurable digital receiver for optically envelope detected half cycle BPSK and MSK radio-on-fiber signals

    DEFF Research Database (Denmark)

    Guerrero Gonzalez, Neil; Prince, Kamau; Zibar, Darko

    2011-01-01

    We present the first known integration of a digital receiver into optically envelope detection radio-on-fiber systems. We also present a re-configurable scheme for two different types of optically envelope detected wireless signals while keeping the complexity of used optical components low. Our...... novel digital receiver consists of a digital signal processing unit integrating functions such as filtering, peak-powers detection, symbol synchronization and signal demodulation for optically envelope detected half-cycle binary phase-shift-keying and minimum-shift-keying signals. Furthermore, radio......-frequency signal down-conversion is not required in our proposed approach; simplifying evens more the optical receiver front-end. We experimentally demonstrate error-free optical transmission (bit-error rate corresponding to 10−3 related to FEC-compatible levels) for both 416.6 Mbit/s half-cycle binary phase...

  5. Development and Application of Optical Coherence Elastography for Detection of Mechanical Property Changes Occurring in Early Osteoarthritis

    Science.gov (United States)

    Hirota, Koji

    We demonstrate a computationally-efficient method for optical coherence elastography (OCE) based on fringe washout method for a spectral-domain OCT (SD-OCT) system. By sending short pulses of mechanical perturbation with ultrasound or shock wave during the image acquisition of alternating depth profiles, we can extract cross-sectional mechanical assessment of tissue in real-time. This was achieved through a simple comparison of the intensity in adjacent depth profiles acquired during the states of perturbation and non-perturbation in order to quantify the degree of induced fringe washout. Although the results indicate that our OCE technique based on the fringe washout effect is sensitive enough to detect mechanical property changes in biological samples, there is some loss of sensitivity in comparison to previous techniques in order to achieve computationally efficiency and minimum modification in both hardware and software in the OCT system. The tissue phantom study was carried with various agar density samples to characterize our OCE technique. Young's modulus measurements were achieved with the atomic force microscopy (AFM) to correlate to our OCE assessment. Knee cartilage samples of monosodium iodoacetate (MIA) rat models were utilized to replicate cartilage damage of a human model. Our proposed OCE technique along with intensity and AFM measurements were applied to the MIA models to assess the damage. The results from both the phantom study and MIA model study demonstrated the strong capability to assess the changes in mechanical properties of the OCE technique. The correlation between the OCE measurements and the Young's modulus values demonstrated in the OCE data that the stiffer material had less magnitude of fringe washout effect. This result is attributed to the fringe washout effect caused by axial motion that the displacement of the scatterers in the stiffer samples in response to the external perturbation induces less fringe washout effect.

  6. Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.

    Science.gov (United States)

    Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S

    2016-09-01

    A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.

  7. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    Science.gov (United States)

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-03-18

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.

  8. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    Directory of Open Access Journals (Sweden)

    Pengyu Zhu

    2016-03-01

    Full Text Available Digital polymerase chain reaction (PCR has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ, sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO genome samples using commercial digital PCR detection systems.

  9. A comparison of digital radiography systems in terms of effective detective quantum efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, Marco; Nitrosi, Andrea; Rivetti, Stefano; Lanconelli, Nico; Pattacini, Pierpaolo; Ginocchi, Vladimiro; Iori, Mauro [Department of Advanced Technology, Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy); Fisica Medica, Ospedale di Sassuolo S.p.A., Modena 41049 (Italy); Alma Mater Studiorum, Physics Department, University of Bologna, Bologna 40127 (Italy); Department of Diagnostic Imaging, Radiology Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy); Department of Diagnostic Imaging, Radiology Unit, Azienda USL, Reggio Emilia 42122 (Italy); Department of Advanced Technology, Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy)

    2012-05-15

    Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems

  10. A comparison of digital radiography systems in terms of effective detective quantum efficiency

    International Nuclear Information System (INIS)

    Bertolini, Marco; Nitrosi, Andrea; Rivetti, Stefano; Lanconelli, Nico; Pattacini, Pierpaolo; Ginocchi, Vladimiro; Iori, Mauro

    2012-01-01

    Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E 0 , which is the exposure at which a system is normally operated, 1/3 E 0 , and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed

  11. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.

    Science.gov (United States)

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-07-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications.

  12. A novel featureless approach to mass detection in digital mammograms based on support vector machines

    Energy Technology Data Exchange (ETDEWEB)

    Campanini, Renato [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Dongiovanni, Danilo [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Iampieri, Emiro [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Lanconelli, Nico [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Masotti, Matteo [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Palermo, Giuseppe [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Riccardi, Alessandro [Department of Physics, University of Bologna, and INFN, Bologna (Italy); Roffilli, Matteo [Department of Computer Science, University of Bologna, Bologna (Italy)

    2004-03-21

    In this work, we present a novel approach to mass detection in digital mammograms. The great variability of the appearance of masses is the main obstacle to building a mass detection method. It is indeed demanding to characterize all the varieties of masses with a reduced set of features. Hence, in our approach we have chosen not to extract any feature, for the detection of the region of interest; in contrast, we exploit all the information available on the image. A multiresolution overcomplete wavelet representation is performed, in order to codify the image with redundancy of information. The vectors of the very-large space obtained are then provided to a first support vector machine (SVM) classifier. The detection task is considered here as a two-class pattern recognition problem: crops are classified as suspect or not, by using this SVM classifier. False candidates are eliminated with a second cascaded SVM. To further reduce the number of false positives, an ensemble of experts is applied: the final suspect regions are achieved by using a voting strategy. The sensitivity of the presented system is nearly 80% with a false-positive rate of 1.1 marks per image, estimated on images coming from the USF DDSM database.

  13. Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography

    International Nuclear Information System (INIS)

    Aufrichtig, Richard

    2000-01-01

    The effect of dose reduction on low-contrast detectability is investigated theoretically and experimentally for a production grade amorphous silicon (a-Si) x-ray detector and compared with a standard thoracic screen-film combination. A non-prewhitening matched filter observer model modified to include a spatial response function and internal noise for the human visual system (HVS) is used to calculate a signal-to-noise ratio (SNR) related to object detectability. Other inputs to the SNR calculation are the detective quantum efficiency (DQE) and the modulation transfer function (MTF) of the imaging system. Besides threshold detectability, the model predicts the equivalent perception dose ratio (EPDR), which is the fraction of the screen-film exposure for which the digital detector provides equal detectability. Images of a contrast-detail phantom are obtained with the digital detector at dose levels corresponding to 27%, 41%, 63% and 100% of the dose used for screen-film. The images are used in a four-alternative forced choice (4-AFC) observer perception study in order to measure threshold detectability. A statistically significant improvement in contrast detectability is measured with the digital detector at 100% and 63% of the screen-film dose. There is no statistical difference between screen-film and digital at 41% of the dose. On average, the experimental EPDR is 44%, which agrees well with the model prediction of 40%. (author)

  14. Assessment of enamel-dentin caries lesions detection using bitewing PSP digital images

    Directory of Open Access Journals (Sweden)

    Marianna Guanaes Gomes Torres

    2011-10-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the detection of enamel-dentin occlusal caries using photostimulable phosphor plates. MATERIAL AND METHODS: The ability to detect enamel-dentin occlusal caries in 607 premolars and molars from 47 patients between 10 and 18 years old, referred to the School of Dentistry of the Federal University of Bahia, Brazil, was evaluated based on clinical and radiographic examinations, using the criteria proposed in a previous study. A total of 156 bitewing digital images were obtained using Digora® (Soredex Medical Systems, Helsinki, Finland phosphor plates. The plates were scanned and the images were captured and displayed on a computer screen. Image evaluation was done using Digora® for Windows 2.1 software, Soredex®. The radiologists were allowed to use enhancement tools to obtain better visibility during scoring of the teeth based on the radiographic criteria proposed in a previous study. Descriptive analysis and chi-squared proportion tests were done at 5% significance level. RESULTS: The results of clinical examination showed a higher prevalence of teeth with a straight dark line or demineralization of the occlusal fissure (score 1 and a lower prevalence of sealed teeth (score 5. In the bitewing digital images, 47 teeth presented visible radiolucency, circumscribed, in dentin under occlusal enamel (enamel-dentin caries lesions. CONCLUSIONS: Correlating the clinical and radiographic findings, it was found that in the majority of teeth diagnosed by radiographic images as having enamel-dentin caries, no caries could be detected by clinical examination.

  15. Lesion size detection in geographic atrophy by polarization-sensitive optical coherence tomography and correlation to conventional imaging techniques.

    Science.gov (United States)

    Schütze, Christopher; Bolz, Matthias; Sayegh, Ramzi; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2013-01-28

    To investigate the reproducibility of automated lesion size detection in patients with geographic atrophy (GA) using polarization-sensitive spectral-domain optical coherence tomography (PS-OCT) and to compare findings with scanning laser ophthalmoscopy (SLO), fundus autofluorescence (FAF), and intensity-based spectral-domain OCT (SD-OCT). Twenty-nine eyes of 22 patients with GA were examined by PS-OCT, selectively identifying the retinal pigment epithelium (RPE). A novel segmentation algorithm was applied, automatically detecting and quantifying areas of RPE atrophy. The reproducibility of the algorithm was assessed, and lesion sizes were correlated with manually delineated SLO, FAF, and intensity-based SD-OCT images to validate the clinical applicability of PS-OCT in GA evaluation. Mean GA lesion size of all patients was 5.28 mm(2) (SD: 4.92) in PS-OCT. Mean variability of individual repeatability measurements was 0.83 mm(2) (minimum: 0.05; maximum: 3.65). Mean coefficient of variation was 0.07 (min: 0.01; max: 0.19). Mean GA area in SLO (Spectralis OCT) was 5.15 mm(2) (SD: 4.72) and 2.5% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area in intensity-based SD-OCT pseudo-SLO images (Cirrus OCT) was 5.14 mm(2) (SD: 4.67) and 2.7% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area of all eyes measured 5.41 mm(2) (SD: 4.75) in FAF, deviating by 2.4% from PS-OCT results (P = 0.89, Pearson correlation coefficient = 0.99, P < 0.01). PS-OCT demonstrated high reproducibility of GA lesion size determination. Results correlated well with SLO, FAF, and intensity-based SD-OCT fundus imaging. PS-OCT may therefore be a valuable and specific imaging modality for automated GA lesion size determination in scientific studies and clinical practice.

  16. Computer-aided detection system applied to full-field digital mammograms

    International Nuclear Information System (INIS)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella; Munoz Cacho, Pedro; Hoffmeister, Jeffrey W.

    2010-01-01

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  17. Comparison of digital tomosynthesis and computed tomography for lung nodule detection in SOS screening program.

    Science.gov (United States)

    Grosso, Maurizio; Priotto, Roberto; Ghirardo, Donatella; Talenti, Alberto; Roberto, Emanuele; Bertolaccini, Luca; Terzi, Alberto; Chauvie, Stéphane

    2017-08-01

    To compare the lung nodules' detection of digital tomosynthesis (DTS) and computed tomography (CT) in the context of the SOS (Studio OSservazionale) prospective screening program for lung cancer detection. One hundred and thirty-two of the 1843 subjects enrolled in the SOS study underwent CT because non-calcified nodules with diameters larger than 5 mm and/or multiple nodules were present in DTS. Two expert radiologists reviewed the exams classifying the nodules based on their radiological appearance and their dimension. LUNG-RADS classification was applied to compare receiver operator characteristics curve between CT and DTS with respect to final diagnosis. CT was used as gold standard. DTS and CT detected 208 and 179 nodules in the 132 subjects, respectively. Of these 208 nodules, 189 (91%) were solid, partially solid, and ground glass opacity. CT confirmed 140/189 (74%) of these nodules but found 4 nodules that were not detected by DTS. DTS and CT were concordant in 62% of the cases applying the 5-point LUNG-RADS scale. The concordance rose to 86% on a suspicious/non-suspicious binary scale. The areas under the curve in receiver operator characteristics were 0.89 (95% CI 0.83-0.94) and 0.80 (95% CI 0.72-0.89) for CT and DTS, respectively. The mean effective dose was 0.09 ± 0.04 mSv for DTS and 4.90 ± 1.20 mSv for CT. The use of a common classification for nodule detection in DTS and CT helps in comparing the two technologies. DTS detected and correctly classified 74% of the nodules seen by CT but lost 4 nodules identified by CT. Concordance between DTS and CT rose to 86% of the nodules when considering LUNG-RADS on a binary scale.

  18. Computer-aided detection system applied to full-field digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella (Dept. of Radiology, Univ. Marques of Valdecilla Hospital, Santander (Spain)), e-mail: avegab@telefonica.net; Munoz Cacho, Pedro (Dept. of Statistics, Univ. Marques of Valdecilla Hospital, Santander (Spain)); Hoffmeister, Jeffrey W. (iCAD, Inc., Nashua, NH (United States))

    2010-12-15

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  19. Development of a duplex droplet digital PCR assay for absolute quantitative detection of "Candidatus Liberibacter asiaticus".

    Science.gov (United States)

    Selvaraj, Vijayanandraj; Maheshwari, Yogita; Hajeri, Subhas; Chen, Jianchi; McCollum, Thomas Greg; Yokomi, Raymond

    2018-01-01

    Huanglongbing (HLB, citrus greening) is a devastating citrus disease affecting citrus production worldwide. It is associated with the bacterium "Candidatus Liberibacter asiaticus" (CLas) and is vectored by the Asian citrus psyllid (ACP). Currently, diagnosis of CLas in regulatory samples is based on real-time quantitative polymerase chain reaction (qPCR) using 16S rRNA gene specific primers/probe. The detection of CLas using qPCR is challenging due to low pathogen titer and uneven distribution in infected plants and exacerbated by sampling issues and presence of inhibitors. This study evaluated a duplex droplet digital polymerase chain reaction (ddPCR) using multi-copy gene targets, 16S and RNR, to simultaneously detect CLas DNA targets in the same sample for unambiguous detection of the HLB pathogen in DNA extracts from citrus leaves and ACP. Standard curve analyses on tenfold dilution series with plasmid, citrus leaf and ACP DNA showed that both ddPCR and qPCR exhibited good linearity and efficiency in the duplex assay. CLas-infected low titer samples were used to validate the duplex ddPCR and qPCR performance and demonstrated that detection rate is higher when both 16S and RNR primers were used in duplex assay. However, the receiver operating characteristic analysis indicated that area under the curve for RNR primer was significantly broader, compared to 16S primers for CLas detection at low target titer. The absolute quantification of CLas at variable titers was reproducible and repeatable for both primer sets and the ddPCR showed higher resilience to PCR inhibitors with citrus leaf and ACP extracts. Hence, the resultant duplex ddPCR assay resulted in a significantly improved detection platform for diagnosis of CLas in samples with low pathogen titer.

  20. Thresholds for human detection of patient setup errors in digitally reconstructed portal images of prostate fields

    International Nuclear Information System (INIS)

    Phillips, Brooke L.; Jiroutek, Michael R.; Tracton, Gregg; Elfervig, Michelle; Muller, Keith E.; Chaney, Edward L.

    2002-01-01

    Purpose: Computer-assisted methods to analyze electronic portal images for the presence of treatment setup errors should be studied in controlled experiments before use in the clinical setting. Validation experiments using images that contain known errors usually report the smallest errors that can be detected by the image analysis algorithm. This paper offers human error-detection thresholds as one benchmark for evaluating the smallest errors detected by algorithms. Unfortunately, reliable data are lacking describing human performance. The most rigorous benchmarks for human performance are obtained under conditions that favor error detection. To establish such benchmarks, controlled observer studies were carried out to determine the thresholds of detectability for in-plane and out-of-plane translation and rotation setup errors introduced into digitally reconstructed portal radiographs (DRPRs) of prostate fields. Methods and Materials: Seventeen observers comprising radiation oncologists, radiation oncology residents, physicists, and therapy students participated in a two-alternative forced choice experiment involving 378 DRPRs computed using the National Library of Medicine Visible Human data sets. An observer viewed three images at a time displayed on adjacent computer monitors. Each image triplet included a reference digitally reconstructed radiograph displayed on the central monitor and two DRPRs displayed on the flanking monitors. One DRPR was error free. The other DRPR contained a known in-plane or out-of-plane error in the placement of the treatment field over a target region in the pelvis. The range for each type of error was determined from pilot observer studies based on a Probit model for error detection. The smallest errors approached the limit of human visual capability. The observer was told what kind of error was introduced, and was asked to choose the DRPR that contained the error. Observer decisions were recorded and analyzed using repeated

  1. A novel method for detecting light source for digital images forensic

    Science.gov (United States)

    Roy, A. K.; Mitra, S. K.; Agrawal, R.

    2011-06-01

    Manipulation in image has been in practice since centuries. These manipulated images are intended to alter facts — facts of ethics, morality, politics, sex, celebrity or chaos. Image forensic science is used to detect these manipulations in a digital image. There are several standard ways to analyze an image for manipulation. Each one has some limitation. Also very rarely any method tried to capitalize on the way image was taken by the camera. We propose a new method that is based on light and its shade as light and shade are the fundamental input resources that may carry all the information of the image. The proposed method measures the direction of light source and uses the light based technique for identification of any intentional partial manipulation in the said digital image. The method is tested for known manipulated images to correctly identify the light sources. The light source of an image is measured in terms of angle. The experimental results show the robustness of the methodology.

  2. A highly accurate wireless digital sun sensor based on profile detecting and detector multiplexing technologies

    Science.gov (United States)

    Wei, Minsong; Xing, Fei; You, Zheng

    2017-01-01

    The advancing growth of micro- and nano-satellites requires miniaturized sun sensors which could be conveniently applied in the attitude determination subsystem. In this work, a profile detecting technology based high accurate wireless digital sun sensor was proposed, which could transform a two-dimensional image into two-linear profile output so that it can realize a high update rate under a very low power consumption. A multiple spots recovery approach with an asymmetric mask pattern design principle was introduced to fit the multiplexing image detector method for accuracy improvement of the sun sensor within a large Field of View (FOV). A FOV determination principle based on the concept of FOV region was also proposed to facilitate both sub-FOV analysis and the whole FOV determination. A RF MCU, together with solar cells, was utilized to achieve the wireless and self-powered functionality. The prototype of the sun sensor is approximately 10 times lower in size and weight compared with the conventional digital sun sensor (DSS). Test results indicated that the accuracy of the prototype was 0.01° within a cone FOV of 100°. Such an autonomous DSS could be equipped flexibly on a micro- or nano-satellite, especially for highly accurate remote sensing applications.

  3. Critical assessment of digital PCR for the detection and quantification of genetically modified organisms.

    Science.gov (United States)

    Demeke, Tigst; Dobnik, David

    2018-07-01

    The number of genetically modified organisms (GMOs) on the market is steadily increasing. Because of regulation of cultivation and trade of GMOs in several countries, there is pressure for their accurate detection and quantification. Today, DNA-based approaches are more popular for this purpose than protein-based methods, and real-time quantitative PCR (qPCR) is still the gold standard in GMO analytics. However, digital PCR (dPCR) offers several advantages over qPCR, making this new technique appealing also for GMO analysis. This critical review focuses on the use of dPCR for the purpose of GMO quantification and addresses parameters which are important for achieving accurate and reliable results, such as the quality and purity of DNA and reaction optimization. Three critical factors are explored and discussed in more depth: correct classification of partitions as positive, correctly determined partition volume, and dilution factor. This review could serve as a guide for all laboratories implementing dPCR. Most of the parameters discussed are applicable to fields other than purely GMO testing. Graphical abstract There are generally three different options for absolute quantification of genetically modified organisms (GMOs) using digital PCR: droplet- or chamber-based and droplets in chambers. All have in common the distribution of reaction mixture into several partitions, which are all subjected to PCR and scored at the end-point as positive or negative. Based on these results GMO content can be calculated.

  4. Volitional Control of Neuromagnetic Coherence

    Directory of Open Access Journals (Sweden)

    Matthew D Sacchet

    2012-12-01

    Full Text Available Coherence of neural activity between circumscribed brain regions has been implicated as an indicator of intracerebral communication in various cognitive processes. While neural activity can be volitionally controlled with neurofeedback, the volitional control of coherence has not yet been explored. Learned volitional control of coherence could elucidate mechanisms of associations between cortical areas and its cognitive correlates and may have clinical implications. Neural coherence may also provide a signal for brain-computer interfaces (BCI. In the present study we used the Weighted Overlapping Segment Averaging (WOSA method to assess coherence between bilateral magnetoencephalograph (MEG sensors during voluntary digit movement as a basis for BCI control. Participants controlled an onscreen cursor, with a success rate of 124 of 180 (68.9%, sign-test p < 0.001 and 84 out of 100 (84%, sign-test p < 0.001. The present findings suggest that neural coherence may be volitionally controlled and may have specific behavioral correlates.

  5. Source coherence impairments in a direct detection direct sequence optical code-division multiple-access system.

    Science.gov (United States)

    Fsaifes, Ihsan; Lepers, Catherine; Lourdiane, Mounia; Gallion, Philippe; Beugin, Vincent; Guignard, Philippe

    2007-02-01

    We demonstrate that direct sequence optical code- division multiple-access (DS-OCDMA) encoders and decoders using sampled fiber Bragg gratings (S-FBGs) behave as multipath interferometers. In that case, chip pulses of the prime sequence codes generated by spreading in time-coherent data pulses can result from multiple reflections in the interferometers that can superimpose within a chip time duration. We show that the autocorrelation function has to be considered as the sum of complex amplitudes of the combined chip as the laser source coherence time is much greater than the integration time of the photodetector. To reduce the sensitivity of the DS-OCDMA system to the coherence time of the laser source, we analyze the use of sparse and nonperiodic quadratic congruence and extended quadratic congruence codes.

  6. Source coherence impairments in a direct detection direct sequence optical code-division multiple-access system

    Science.gov (United States)

    Fsaifes, Ihsan; Lepers, Catherine; Lourdiane, Mounia; Gallion, Philippe; Beugin, Vincent; Guignard, Philippe

    2007-02-01

    We demonstrate that direct sequence optical code- division multiple-access (DS-OCDMA) encoders and decoders using sampled fiber Bragg gratings (S-FBGs) behave as multipath interferometers. In that case, chip pulses of the prime sequence codes generated by spreading in time-coherent data pulses can result from multiple reflections in the interferometers that can superimpose within a chip time duration. We show that the autocorrelation function has to be considered as the sum of complex amplitudes of the combined chip as the laser source coherence time is much greater than the integration time of the photodetector. To reduce the sensitivity of the DS-OCDMA system to the coherence time of the laser source, we analyze the use of sparse and nonperiodic quadratic congruence and extended quadratic congruence codes.

  7. Automatic detection and classification of damage zone(s) for incorporating in digital image correlation technique

    Science.gov (United States)

    Bhattacharjee, Sudipta; Deb, Debasis

    2016-07-01

    Digital image correlation (DIC) is a technique developed for monitoring surface deformation/displacement of an object under loading conditions. This method is further refined to make it capable of handling discontinuities on the surface of the sample. A damage zone is referred to a surface area fractured and opened in due course of loading. In this study, an algorithm is presented to automatically detect multiple damage zones in deformed image. The algorithm identifies the pixels located inside these zones and eliminate them from FEM-DIC processes. The proposed algorithm is successfully implemented on several damaged samples to estimate displacement fields of an object under loading conditions. This study shows that displacement fields represent the damage conditions reasonably well as compared to regular FEM-DIC technique without considering the damage zones.

  8. Detectability of the mediastinal lines : comparison of conventional film-screen radiography and digital radiography

    International Nuclear Information System (INIS)

    Shin, Hye Young; Park, Kyung Joo; Kang, Doo Kyung; Lee, Kang Lai; Han, Chaing Jin; Suh, Jung Ho

    1998-01-01

    Using dynamic range compression (DRC) processing, this study compared the detectability of mediastinal lines by conventional film screen radiography (FS) and by storage phosphor digital radiography (DR). We selected 200 normal consecutive chest radiographs (100 FS, 100 DR); dynamic range compression was applied to DR processing and moving grids were used in both systems. Seven mediastinal lines (left paraspinal, right paraspinal, azygoesophageal, left para-aortic, posterio junctional, anterior junctional and right paratracheal) were scored from 0 point to 3 point (0: not visible, 1 : suspiciously visible, 2 : visible, but not clear, 3: clearly visible) according to visibility and sharpness, as agreed by a radiologist and a resident. The differences between the two modalities were compared and analyzed by chi-square test. DR processed with DRC visualizes mediastinal lines more frequently and clearly than conventional FS, and is therefore thought to be useful for the evaluation of mediastinal diseases. (author). 14 refs., 2 tabs., 2 figs

  9. A simple infrared-augmented digital photography technique for detection of pupillary abnormalities.

    Science.gov (United States)

    Shazly, Tarek A; Bonhomme, G R

    2015-03-01

    The purpose of the study was to describe a simple infrared photography technique to aid in the diagnosis and documentation of pupillary abnormalities. An unmodified 12-megapixel "point and shoot" digital camera was used to obtain binocular still photos and videos under different light conditions with near-infrared illuminating frames. The near-infrared light of 850 nm allows the capture of clear pupil images in both dim and bright light conditions. It also allows easy visualization of the pupil despite pigmented irides by augmenting the contrast between the iris and the pupil. The photos and videos obtained illustrated a variety of pupillary abnormalities using the aforementioned technique. This infrared-augmented photography technique supplements medical education, and aids in the more rapid detection, diagnosis, and documentation of a wide spectrum of pupillary abnormalities. Its portability and ease of use with minimal training complements the education of trainees and facilitates the establishment of difficult diagnoses.

  10. Simple lock-in detection technique utilizing multiple harmonics for digital PGC demodulators.

    Science.gov (United States)

    Duan, Fajie; Huang, Tingting; Jiang, Jiajia; Fu, Xiao; Ma, Ling

    2017-06-01

    A simple lock-in detection technique especially suited for digital phase-generated carrier (PGC) demodulators is proposed in this paper. It mixes the interference signal with rectangular waves whose Fourier expansions contain multiple odd or multiple even harmonics of the carrier to recover the quadrature components needed for interference phase demodulation. In this way, the use of a multiplier is avoided and the efficiency of the algorithm is improved. Noise performance with regard to light intensity variation and circuit noise is analyzed theoretically for both the proposed technique and the traditional lock-in technique, and results show that the former provides a better signal-to-noise ratio than the latter with proper modulation depth and average interference phase. Detailed simulations were conducted and the theoretical analysis was verified. A fiber-optic Michelson interferometer was constructed and the feasibility of the proposed technique is demonstrated.

  11. Robust Nucleus/Cell Detection and Segmentation in Digital Pathology and Microscopy Images: A Comprehensive Review

    Science.gov (United States)

    Xing, Fuyong; Yang, Lin

    2016-01-01

    Digital pathology and microscopy image analysis is widely used for comprehensive studies of cell morphology or tissue structure. Manual assessment is labor intensive and prone to inter-observer variations. Computer-aided methods, which can significantly improve the objectivity and reproducibility, have attracted a great deal of interest in recent literatures. Among the pipeline of building a computer-aided diagnosis system, nucleus or cell detection and segmentation play a very important role to describe the molecular morphological information. In the past few decades, many efforts have been devoted to automated nucleus/cell detection and segmentation. In this review, we provide a comprehensive summary of the recent state-of-the-art nucleus/cell segmentation approaches on different types of microscopy images including bright-field, phase-contrast, differential interference contrast (DIC), fluorescence, and electron microscopies. In addition, we discuss the challenges for the current methods and the potential future work of nucleus/cell detection and segmentation. PMID:26742143

  12. Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Ji-wook Jeong

    2016-01-01

    Full Text Available We propose computer-aided detection (CADe algorithm for microcalcification (MC clusters in reconstructed digital breast tomosynthesis (DBT images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D objectness response function and a connected-component segmentation method was applied to extract the cluster seed objects as potential clustering centers of MCs. Secondly, a signal-to-noise ratio (SNR enhanced image was also generated to detect the individual MC candidates and prescreen the MC-like objects. Each cluster seed candidate was prescreened by counting neighboring individual MC candidates nearby the cluster seed object according to several microcalcification clustering criteria. As a second step, we introduced bounding boxes for the accepted seed candidate, clustered all the overlapping cubes, and examined. After the FP reduction step, the average number of FPs per case was estimated to be 2.47 per DBT volume with a sensitivity of 83.3%.

  13. Automatic phase aberration compensation for digital holographic microscopy based on deep learning background detection.

    Science.gov (United States)

    Nguyen, Thanh; Bui, Vy; Lam, Van; Raub, Christopher B; Chang, Lin-Ching; Nehmetallah, George

    2017-06-26

    We propose a fully automatic technique to obtain aberration free quantitative phase imaging in digital holographic microscopy (DHM) based on deep learning. The traditional DHM solves the phase aberration compensation problem by manually detecting the background for quantitative measurement. This would be a drawback in real time implementation and for dynamic processes such as cell migration phenomena. A recent automatic aberration compensation approach using principle component analysis (PCA) in DHM avoids human intervention regardless of the cells' motion. However, it corrects spherical/elliptical aberration only and disregards the higher order aberrations. Traditional image segmentation techniques can be employed to spatially detect cell locations. Ideally, automatic image segmentation techniques make real time measurement possible. However, existing automatic unsupervised segmentation techniques have poor performance when applied to DHM phase images because of aberrations and speckle noise. In this paper, we propose a novel method that combines a supervised deep learning technique with convolutional neural network (CNN) and Zernike polynomial fitting (ZPF). The deep learning CNN is implemented to perform automatic background region detection that allows for ZPF to compute the self-conjugated phase to compensate for most aberrations.

  14. Comparison between digital PCR and real-time PCR in detection of Salmonella typhimurium in milk.

    Science.gov (United States)

    Wang, Meng; Yang, Junjie; Gai, Zhongtao; Huo, Shengnan; Zhu, Jianhua; Li, Jun; Wang, Ranran; Xing, Sheng; Shi, Guosheng; Shi, Feng; Zhang, Lei

    2018-02-02

    As a kind of zero-tolerance foodborne pathogens, Salmonella typhimurium poses a great threat to quality of food products and public health. Hence, rapid and efficient approaches to identify Salmonella typhimurium are urgently needed. Combined with PCR and fluorescence technique, real-time PCR (qPCR) and digital PCR (ddPCR) are regarded as suitable tools for detecting foodborne pathogens. To compare the effect between qPCR and ddPCR in detecting Salmonella typhimurium, a series of nucleic acid, pure strain culture and spiking milk samples were applied and the resistance to inhibitors referred in this article as well. Compared with qPCR, ddPCR exhibited more sensitive (10 -4 ng/μl or 10 2 cfu/ml) and less pre-culturing time (saving 2h). Moreover, ddPCR had stronger resistance to inhibitors than qPCR, yet absolute quantification hardly performed when target's concentration over 1ng/μl or 10 6 cfu/ml. This study provides an alternative strategy in detecting foodborne Salmonella typhimurium. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Effect of CT digital image compression on detection of coronary artery calcification

    International Nuclear Information System (INIS)

    Zheng, L.M.; Sone, S.; Itani, Y.; Wang, Q.; Hanamura, K.; Asakura, K.; Li, F.; Yang, Z.G.; Wang, J.C.; Funasaka, T.

    2000-01-01

    Purpose: To test the effect of digital compression of CT images on the detection of small linear or spotted high attenuation lesions such as coronary artery calcification (CAC). Material and methods: Fifty cases with and 50 without CAC were randomly selected from a population that had undergone spiral CT of the thorax for screening lung cancer. CT image data were compressed using JPEG (Joint Photographic Experts Group) or wavelet algorithms at ratios of 10:1, 20:1 or 40:1. Five radiologists reviewed the uncompressed and compressed images on a cathode-ray-tube. Observer performance was evaluated with receiver operating characteristic analysis. Results: CT images compressed at a ratio as high as 20:1 were acceptable for primary diagnosis of CAC. There was no significant difference in the detection accuracy for CAC between JPEG and wavelet algorithms at the compression ratios up to 20:1. CT images were more vulnerable to image blurring on the wavelet compression at relatively lower ratios, and 'blocking' artifacts occurred on the JPEG compression at relatively higher ratios. Conclusion: JPEG and wavelet algorithms allow compression of CT images without compromising their diagnostic value at ratios up to 20:1 in detecting small linear or spotted high attenuation lesions such as CAC, and there was no difference between the two algorithms in diagnostic accuracy

  16. Detection of Life Threatening Ventricular Arrhythmia Using Digital Taylor Fourier Transform.

    Science.gov (United States)

    Tripathy, Rajesh K; Zamora-Mendez, Alejandro; de la O Serna, José A; Paternina, Mario R Arrieta; Arrieta, Juan G; Naik, Ganesh R

    2018-01-01

    Accurate detection and classification of life-threatening ventricular arrhythmia episodes such as ventricular fibrillation (VF) and rapid ventricular tachycardia (VT) from electrocardiogram (ECG) is a challenging problem for patient monitoring and defibrillation therapy. This paper introduces a novel method for detection and classification of life-threatening ventricular arrhythmia episodes. The ECG signal is decomposed into various oscillatory modes using digital Taylor-Fourier transform (DTFT). The magnitude feature and a novel phase feature namely the phase difference (PD) are evaluated from the mode Taylor-Fourier coefficients of ECG signal. The least square support vector machine (LS-SVM) classifier with linear and radial basis function (RBF) kernels is employed for detection and classification of VT vs. VF, non-shock vs. shock and VF vs. non-VF arrhythmia episodes. The accuracy, sensitivity, and specificity values obtained using the proposed method are 89.81, 86.38, and 93.97%, respectively for the classification of Non-VF and VF episodes. Comparison with the performance of the state-of-the-art features demonstrate the advantages of the proposition.

  17. Detection method of proximal caries using line profile in digital intra-oral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Min Ja; Choi, Sam Jin; Park, Hun Kuk [Department of Oral and Maxillofacial Radiology, School of Dentistry and Institute of Oral Biology, Kyung Hee University, Seoul (Korea, Republic of); Park, Jeong Hoon [Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2009-12-15

    The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Mean values of D were 0.0354 {+-} 0.0155 in non-caries and 0.2632 {+-} 0.0982 in caries (p<0.001). The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  18. Automatic centroid detection and surface measurement with a digital Shack–Hartmann wavefront sensor

    International Nuclear Information System (INIS)

    Yin, Xiaoming; Zhao, Liping; Li, Xiang; Fang, Zhongping

    2010-01-01

    With the breakthrough of manufacturing technologies, the measurement of surface profiles is becoming a big issue. A Shack–Hartmann wavefront sensor (SHWS) provides a promising technology for non-contact surface measurement with a number of advantages over interferometry. The SHWS splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. So the accuracy of the centroid measurement determines the accuracy of the SHWS. In this paper, we have presented a new centroid measurement algorithm based on an adaptive thresholding and dynamic windowing method by utilizing image-processing techniques. Based on this centroid detection method, we have developed a digital SHWS system which can automatically detect centroids of focal spots, reconstruct the wavefront and measure the 3D profile of the surface. The system has been tested with various simulated and real surfaces such as flat surfaces, spherical and aspherical surfaces as well as deformable surfaces. The experimental results demonstrate that the system has good accuracy, repeatability and immunity to optical misalignment. The system is also suitable for on-line applications of surface measurement

  19. Detection method of proximal caries using line profile in digital intra-oral radiography

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Min Ja; Choi, Sam Jin; Park, Hun Kuk; Park, Jeong Hoon

    2009-01-01

    The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Mean values of D were 0.0354 ± 0.0155 in non-caries and 0.2632 ± 0.0982 in caries (p<0.001). The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  20. Computer-aided detection of masses in digital tomosynthesis mammography: Comparison of three approaches

    International Nuclear Information System (INIS)

    Chan Heangping; Wei Jun; Zhang Yiheng; Helvie, Mark A.; Moore, Richard H.; Sahiner, Berkman; Hadjiiski, Lubomir; Kopans, Daniel B.

    2008-01-01

    The authors are developing a computer-aided detection (CAD) system for masses on digital breast tomosynthesis mammograms (DBT). Three approaches were evaluated in this study. In the first approach, mass candidate identification and feature analysis are performed in the reconstructed three-dimensional (3D) DBT volume. A mass likelihood score is estimated for each mass candidate using a linear discriminant analysis (LDA) classifier. Mass detection is determined by a decision threshold applied to the mass likelihood score. A free response receiver operating characteristic (FROC) curve that describes the detection sensitivity as a function of the number of false positives (FPs) per breast is generated by varying the decision threshold over a range. In the second approach, prescreening of mass candidate and feature analysis are first performed on the individual two-dimensional (2D) projection view (PV) images. A mass likelihood score is estimated for each mass candidate using an LDA classifier trained for the 2D features. The mass likelihood images derived from the PVs are backprojected to the breast volume to estimate the 3D spatial distribution of the mass likelihood scores. The FROC curve for mass detection can again be generated by varying the decision threshold on the 3D mass likelihood scores merged by backprojection. In the third approach, the mass likelihood scores estimated by the 3D and 2D approaches, described above, at the corresponding 3D location are combined and evaluated using FROC analysis. A data set of 100 DBT cases acquired with a GE prototype system at the Breast Imaging Laboratory in the Massachusetts General Hospital was used for comparison of the three approaches. The LDA classifiers with stepwise feature selection were designed with leave-one-case-out resampling. In FROC analysis, the CAD system for detection in the DBT volume alone achieved test sensitivities of 80% and 90% at average FP rates of 1.94 and 3.40 per breast, respectively. With the

  1. Mass detection in digital breast tomosynthesis: Deep convolutional neural network with transfer learning from mammography.

    Science.gov (United States)

    Samala, Ravi K; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A; Wei, Jun; Cha, Kenny

    2016-12-01

    Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a

  2. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer.

    Science.gov (United States)

    Roganovic, Dragana; Djilas, Dragana; Vujnovic, Sasa; Pavic, Dag; Stojanov, Dragan

    2015-11-16

    Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI), digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities. We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS) was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC) curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p tomosynthesis and breast MRI was not significant (p=0.20).

  3. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Dragana Roganovic

    2015-11-01

    Full Text Available Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI, digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities.  We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p < 0.001, while the difference between breast tomosynthesis and breast MRI was not significant (p = 0.20. 

  4. A critical period of corticomuscular and EMG-EMG coherence detection in healthy infants aged 9-25weeks

    DEFF Research Database (Denmark)

    Ritterband-Rosenbaum, Anina; Herskind, Anna; Li, Xi

    2017-01-01

    The early postnatal development of functional corticospinal connections in human infants is not fully clarified. We used EEG and EMG to investigate the development of corticomuscular and intramuscular coherence as indicators of functional corticospinal connectivity in healthy infants aged 1-66 we...

  5. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  6. Use of the Wechsler Adult Intelligence Scale Digit Span subtest for malingering detection: a meta-analytic review.

    Science.gov (United States)

    Jasinski, Lindsey J; Berry, David T R; Shandera, Anni L; Clark, Jessica A

    2011-03-01

    Twenty-four studies utilizing the Wechsler Adult Intelligence Scale (WAIS) Digit Span subtest--either the Reliable Digit Span (RDS) or Age-Corrected Scaled Score (DS-ACSS) variant--for malingering detection were meta-analytically reviewed to evaluate their effectiveness in detecting malingered neurocognitive dysfunction. RDS and DS-ACSS effectively discriminated between honest responders and dissimulators, with average weighted effect sizes of 1.34 and 1.08, respectively. No significant differences were found between RDS and DS-ACSS. Similarly, no differences were found between the Digit Span subtest from the WAIS or Wechsler Memory Scale (WMS). Strong specificity and moderate sensitivity were observed, and optimal cutting scores are recommended.

  7. Detection of the aortic intimal tears by using 3D digital topology

    Science.gov (United States)

    Lohou, Christophe; Miguel, Bruno

    2011-03-01

    Aortic dissection is a real problem of public health, it is a medical emergency and may quickly lead to death. Aortic dissection is caused by aortal tissue perforation because of blood pressure. It consists of tears (or holes of the intimal tissue) inside lumens. These tears are difficult to detect because they do not correspond to a filled organ to segment; they are usually visually retrieved by radiologists by examining gray level variation on successive image slices, but it remains a very difficult and error-prone task. Our purpose is to detect these intimal tears to help cardiac surgeons in making diagnosis. It would be useful either during a preoperative phase (visualization and location of tears, endoprothesis sizing); or during a peroperative phase (a registration of tears on angiographic images would lead to a more accuracy of surgeon's gestures and thus would enhance care of patient). At this aim, we use Aktouf et al.'s holes filling algorithm proposed in the field of digital topology. This algorithm permits the filling of holes of a 3D binary object by using topological notions - the holes are precisely the intimal tears for our aortic dissection images, after a first preprocessing step. As far as we know, this is the first time that such a proposal is made, even if it is a crucial data for cardiac surgeons. Our study is a preliminary and innovative work; our results are nevertheless considered satisfactory. This approach would also gain to be known to specialists of other diseases.

  8. The effect of loading methods and parameters on defect detection in digital shearography

    Science.gov (United States)

    Yang, Fu; Ye, Xingchen; Qiu, Zisheng; Zhang, Borui; Zhong, Ping; Liang, ZhiYong; Sun, Zeyu; Zhu, Shu

    Digital Shearography Speckle Pattern Interferometry (DSSPI) is a non-destructive testing technique, which has a wide range of applications in industrial field due to the merits of non-contact, fast response, full-field measurement and high sensitivity. However, in the real application, the loading methods and parameters usually depend on the experience of the operator, which affect the effectiveness and accuracy of the test. Based on this background and the principle of DSSPI, a model using finite element analysis software and Matlab is established to simulate the defects detections of aluminum plate and composite laminates under different loading conditions. The simulation covers loading methods, shearing direction, shearing amount, loading intensity, defect size, defect depth and defect position. In order to quantify the testing effect, a parameter named the deviation D is first defined. And through the parameter D, the simulation system can evaluate the system detection ability. The work in this paper can provide systematic guidance for the choice of loading methods and parameters in the real DSSPI experiment system.

  9. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  10. Back Translation: An Emerging Sophisticated Cyber Strategy to Subvert Advances in "Digital Age" Plagiarism Detection and Prevention

    Science.gov (United States)

    Jones, Michael; Sheridan, Lynnaire

    2015-01-01

    Advances have been made in detecting and deterring the student plagiarism that has accompanied the uptake and development of the internet. Many authors from the late 1990s onwards grappled with plagiarism in the digital age, presenting articles that were provoking and established the foundation for strategies to address cyber plagiarism, including…

  11. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    International Nuclear Information System (INIS)

    Clauser, Paola; Nagl, Georg; Helbich, Thomas H.; Pinker-Domenig, Katja; Weber, Michael; Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T.

    2016-01-01

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  12. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola, E-mail: paola.clauser@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Nagl, Georg [Department for Radiology and Interventional Radiology, Landesklinikum Horn, Spitalgasse 10, 3580 Horn (Austria); Helbich, Thomas H., E-mail: thomas.helbich@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Pinker-Domenig, Katja [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Weber, Michael [Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T. [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2016-12-15

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  13. Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

    Science.gov (United States)

    Tseitlin, Mark; Yu, Zhelin; Quine, Richard W; Rinard, George A; Eaton, Sandra S; Eaton, Gareth R

    2014-12-01

    The use of multiple synchronized outputs from an arbitrary waveform generator (AWG) provides the opportunity to perform EPR experiments differently than by conventional EPR. We report a method for reconstructing the quadrature EPR spectrum from periodic signals that are generated with sinusoidal magnetic field modulation such as continuous wave (CW), multiharmonic, or rapid scan experiments. The signal is down-converted to an intermediate frequency (IF) that is less than the field scan or field modulation frequency and then digitized in a single channel. This method permits use of a high-pass analog filter before digitization to remove the strong non-EPR signal at the IF, that might otherwise overwhelm the digitizer. The IF is the difference between two synchronized X-band outputs from a Tektronix AWG 70002A, one of which is for excitation and the other is the reference for down-conversion. To permit signal averaging, timing was selected to give an exact integer number of full cycles for each frequency. In the experiments reported here the IF was 5kHz and the scan frequency was 40kHz. To produce sinusoidal rapid scans with a scan frequency eight times IF, a third synchronized output generated a square wave that was converted to a sine wave. The timing of the data acquisition with a Bruker SpecJet II was synchronized by an external clock signal from the AWG. The baseband quadrature signal in the frequency domain was reconstructed. This approach has the advantages that (i) the non-EPR response at the carrier frequency is eliminated, (ii) both real and imaginary EPR signals are reconstructed from a single physical channel to produce an ideal quadrature signal, and (iii) signal bandwidth does not increase relative to baseband detection. Spectra were obtained by deconvolution of the reconstructed signals for solid BDPA (1,3-bisdiphenylene-2-phenylallyl) in air, 0.2mM trityl OX63 in water, 15 N perdeuterated tempone, and a nitroxide with a 0.5G partially-resolved proton

  14. Coherent hybrid electromagnetic field imaging

    Science.gov (United States)

    Cooke, Bradly J [Jemez Springs, NM; Guenther, David C [Los Alamos, NM

    2008-08-26

    An apparatus and corresponding method for coherent hybrid electromagnetic field imaging of a target, where an energy source is used to generate a propagating electromagnetic beam, an electromagnetic beam splitting means to split the beam into two or more coherently matched beams of about equal amplitude, and where the spatial and temporal self-coherence between each two or more coherently matched beams is preserved. Two or more differential modulation means are employed to modulate each two or more coherently matched beams with a time-varying polarization, frequency, phase, and amplitude signal. An electromagnetic beam combining means is used to coherently combine said two or more coherently matched beams into a coherent electromagnetic beam. One or more electromagnetic beam controlling means are used for collimating, guiding, or focusing the coherent electromagnetic beam. One or more apertures are used for transmitting and receiving the coherent electromagnetic beam to and from the target. A receiver is used that is capable of square-law detection of the coherent electromagnetic beam. A waveform generator is used that is capable of generation and control of time-varying polarization, frequency, phase, or amplitude modulation waveforms and sequences. A means of synchronizing time varying waveform is used between the energy source and the receiver. Finally, a means of displaying the images created by the interaction of the coherent electromagnetic beam with target is employed.

  15. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  16. A new approach to develop computer-aided detection schemes of digital mammograms

    Science.gov (United States)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  17. A new paradigm of oral cancer detection using digital infrared thermal imaging

    Science.gov (United States)

    Chakraborty, M.; Mukhopadhyay, S.; Dasgupta, A.; Banerjee, S.; Mukhopadhyay, S.; Patsa, S.; Ray, J. G.; Chaudhuri, K.

    2016-03-01

    Histopathology is considered the gold standard for oral cancer detection. But a major fraction of patient pop- ulation is incapable of accessing such healthcare facilities due to poverty. Moreover, such analysis may report false negatives when test tissue is not collected from exact cancerous location. The proposed work introduces a pioneering computer aided paradigm of fast, non-invasive and non-ionizing modality for oral cancer detection us- ing Digital Infrared Thermal Imaging (DITI). Due to aberrant metabolic activities in carcinogenic facial regions, heat signatures of patients are different from that of normal subjects. The proposed work utilizes asymmetry of temperature distribution of facial regions as principle cue for cancer detection. Three views of a subject, viz. front, left and right are acquired using long infrared (7:5 - 13μm) camera for analysing distribution of temperature. We study asymmetry of facial temperature distribution between: a) left and right profile faces and b) left and right half of frontal face. Comparison of temperature distribution suggests that patients manifest greater asymmetry compared to normal subjects. For classification, we initially use k-means and fuzzy k-means for unsupervised clustering followed by cluster class prototype assignment based on majority voting. Average classification accuracy of 91:5% and 92:8% are achieved by k-mean and fuzzy k-mean framework for frontal face. The corresponding metrics for profile face are 93:4% and 95%. Combining features of frontal and profile faces, average accuracies are increased to 96:2% and 97:6% respectively for k-means and fuzzy k-means framework.

  18. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    Science.gov (United States)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of

  19. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  20. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Fercher, A.F.; Andersen, Peter E.

    2017-01-01

    Optical coherence tomography (OCT) is a technique that is used to peer inside a body noninvasively. Tissue structure defined by tissue absorption and scattering coefficients, and the speed of blood flow, are derived from the characteristics of light remitted by the body. Singly backscattered light...... detected by partial coherence interferometry (PCI) is used to synthesize the tomographic image coded in false colors. A prerequisite of this technique is a low time-coherent but high space-coherent light source, for example, a superluminescent diode or a supercontinuum source. Alternatively, the imaging...... technique can be realized by using ultrafast wavelength scanning light sources. For tissue imaging, the light source wavelengths are restricted to the red and near-infrared (NIR) region from about 600 to 1300 nm, the so-called therapeutic window, where absorption (μa ≈ 0.01 mm−1) is small enough. Transverse...

  1. Detection and Isolation of Digital Dermatitis Treponemes from Bovine Pressure Sores.

    Science.gov (United States)

    Clegg, S R; Crosby-Durrani, H E; Bell, J; Blundell, R; Blowey, R W; Carter, S D; Evans, N J

    2016-05-01

    Pressure sores cause severe pain and discomfort in hospitalized people and in farmed cattle and are often infected with unknown bacteria. Pressure sores occur on the upper legs of 6-10% of recumbent cattle and are generally considered to be caused by constant pressure, commonly on bony areas of the limbs. This study analyzed pressure sores taken from the upper limbs of 14 cattle using isolation in culture and nested polymerase chain reaction (PCR) to detect treponemes associated with digital dermatitis (DD). A 100% association of DD treponemes with the pressure sores was demonstrated, but treponemes were shown not to be part of the normal skin microbiota. Immunohistochemistry showed an association of DD treponemes with lesions and particularly with the hair follicles in lesions, identifying the bacteria deep within wounds, thereby suggesting that they could contribute to lesion pathogenesis. The bacteria isolated from the pressure sore lesions were similar or identical on analysis of the 16S rRNA gene to those found in DD foot lesions in cattle, suggesting the same bacteria can infect multiple lesions. Indeed, the results of this study suggest that these spirochaetal bacteria may be expanding in host range and in their ability to colonize different tissues and contribute to a range of disease manifestations in farm animals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. An iPhone-based digital image colorimeter for detecting tetracycline in milk.

    Science.gov (United States)

    Masawat, Prinya; Harfield, Antony; Namwong, Anan

    2015-10-01

    An iPhone-based digital image colorimeter (DIC) was fabricated as a portable tool for monitoring tetracycline (TC) in bovine milk. An application named ColorConc was developed for the iPhone that utilizes an image matching algorithm to determine the TC concentration in a solution. The color values; red (R), green (G), blue (B), hue (H), saturation (S), brightness (V), and gray (Gr) were measured from each pictures of the TC standard solutions. TC solution extracted from milk samples using solid phase extraction (SPE) was captured and the concentration was predicted by comparing color values with those collected in a database. The amount of TC could be determined in the concentration range of 0.5-10 μg mL(-1). The proposed DIC-iPhone is able to provide a limit of detection (LOD) of 0.5 μg mL(-1) and limit of quantitation (LOQ) of 1.5 μg mL(-1). The enrichment factor was 70 and color of the extracted milk sample was a strong yellow solution after SPE. Therefore, the SPE-DIC-iPhone could be used for the assay of TC residues in milk at the concentration lower than LOD and LOQ of the proposed technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  4. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  5. Detection of unruptured familial intracranial aneurysms by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Berg, H.W.M. ter; Regional Hospital Almelo; Overtoom, T.M.D.; Ludwig, J.W.; Bijlsma, J.B.; Tulleken, C.A.F.; Willemse, J.

    1987-01-01

    The authors discuss the detection of intracranial aneurysms (IA) by means of intravenous digital angiography (ivDSA) in (a)symptomatic first degree relatives of families in which more than two or more individuals have IA. ivDSA is an almost noninvasive and low-risk diagnostic procedure. Screening, by means of ivDSA, of two affected families is described. In family I which includes 7 members with proven IA, ivDSA has been carried out in 36 asymptomatic individuals: in one, a 6x15 mm aneurysm was found at the left posterior communicating artery (PCoA). In family II, including one member with a proven IA and another with a subarachnoidal hemorrhage, ivDSA has been carried out in 4 members: one aneurysm with a diameter of 6 mm was found at the left PCoA. Conventional cerebral angiography (CCA) confirmed both IA's. Neurosurgical treatment followed. The advantages and disadvantages of ivDSA vs. CCA as elective screening procedure in such cases are discussed. Screening of asymptomatic first degree relatives of cases with familial IA by means of ivDSA is strongly advocated. (orig.)

  6. Comparison of Digital Tomosynthesis and Chest Radiography for the Detection of Noncalcified Pulmonary and Hilar Lesions.

    Science.gov (United States)

    Galea, Angela; Adlan, Tarig; Gay, David; Roobottom, Carl; Dubbins, Paul; Riordan, Richard

    2015-09-01

    The aim of this study was to compare the sensitivity and specificity of chest digital tomosynthesis (DTS) with chest radiography (CXR) for the detection of noncalcified pulmonary nodules and hilar lesions using computed tomography (CT) as the reference standard. A total of 78 patients with suspected noncalcified pulmonary lesions on CXR were included in the study. Two radiologists, blinded to the history and CT, analyzed the CXR and the DTS images (separately), whereas a third radiologist analyzed the CXR and DTS images together. Noncalcified intrapulmonary nodules and hilar lesions were recorded for analysis. The interobserver agreement for CXR and DTS was assessed, and the time taken to report the images was recorded. A total of 202 lesions were recorded in 78 patients. There were 111 true lesions confirmed on CT in 53 patients; in 25 patients subsequent CT excluded a lesion. The overall sensitivity was 32% for CXR and 49% for DTS. This improved to 54% when the posteroanterior CXR and DTS were reviewed together (CXR-DTS). The overall specificities for CXR, DTS, and CXR-DTS were 49%, 96%, and 98%, respectively. There were 56 suspected hilar lesions with subgroup sensitivities of 76% for CXR, 65% for DTS, and 76% for CXR-DTS. The specificity for hilar lesions was 59%, 92%, and 97% for CXR, DTS, and CXR-DTS, respectively. DTS significantly improves the detectability of noncalcified nodules when compared with and when used in combination with CXR. The specificity and interobserver agreement of DTS in the diagnosis of suspected noncalcified pulmonary nodules and hilar lesions are significantly better than those of CXR and approaches those of CT.

  7. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described as the o......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...

  8. The ν-cleus experiment: a gram-scale fiducial-volume cryogenic detector for the first detection of coherent neutrino-nucleus scattering

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, R.; Rothe, J.; Angloher, G.; Hauff, D.; Mancuso, M.; Petricca, F.; Proebst, F.; Seidel, W.; Stodolsky, L. [Max-Planck-Institut fuer Physik, Muenchen (Germany); Bento, A. [Universidade de Coimbra, CIUC, Departamento de Fisica, Coimbra (Portugal); Guetlein, A.; Kluck, H.; Schieck, J. [Institut fuer Hochenergiephysik, Oesterreichische Akademie der Wissenschaften, Vienna (Austria); Vienna University of Technology, Atominstitut, Vienna (Austria); Oberauer, L.; Schoenert, S. [Technische Universitaet Muenchen, Physik-Department, Garching (Germany)

    2017-08-15

    We discuss a small-scale experiment, called ν-cleus, for the first detection of coherent neutrino-nucleus scattering by probing nuclear-recoil energies down to the 10 eV regime. The detector consists of low-threshold CaWO{sub 4} and Al{sub 2}O{sub 3} calorimeter arrays with a total mass of about 10 g and several cryogenic veto detectors operated at millikelvin temperatures. Realizing a fiducial volume and a multi-element target, the detector enables active discrimination of γ, neutron and surface backgrounds. A first prototype Al{sub 2}O{sub 3} device, operated above ground in a setup without shielding, has achieved an energy threshold of ∝20 eV and further improvements are in reach. A sensitivity study for the detection of coherent neutrino scattering at nuclear power plants shows a unique discovery potential (5 σ) within a measuring time of

  9. Comparison of Color Fundus Photography, Infrared Fundus Photography, and Optical Coherence Tomography in Detecting Retinal Hamartoma in Patients with Tuberous Sclerosis Complex.

    Science.gov (United States)

    Bai, Da-Yong; Wang, Xu; Zhao, Jun-Yang; Li, Li; Gao, Jun; Wang, Ning-Li

    2016-05-20

    A sensitive method is required to detect retinal hamartomas in patients with tuberous sclerosis complex (TSC). The aim of the present study was to compare the color fundus photography, infrared imaging (IFG), and optical coherence tomography (OCT) in the detection rate of retinal hamartoma in patients with TSC. This study included 11 patients (22 eyes) with TSC, who underwent color fundus photography, IFG, and spectral-domain OCT to detect retinal hamartomas. TSC1 and TSC2RESULTS: The mean age of the 11 patients was 8.0 ± 2.1 years. The mean spherical equivalent was -0.55 ± 1.42 D by autorefraction with cycloplegia. In 11 patients (22 eyes), OCT, infrared fundus photography, and color fundus photography revealed 26, 18, and 9 hamartomas, respectively. The predominant hamartoma was type I (55.6%). All the hamartomas that detected by color fundus photography or IFG can be detected by OCT. Among the methods of color fundus photography, IFG, and OCT, the OCT has higher detection rate for retinal hamartoma in TSC patients; therefore, OCT might be promising for the clinical diagnosis of TSC.

  10. Comparing whole slide digital images versus traditional glass slides in the detection of common microscopic features seen in dermatitis

    Directory of Open Access Journals (Sweden)

    Nikki S Vyas

    2016-01-01

    Full Text Available Background: The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. Methods: Hematoxylin and eosin and periodic acid-Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany. Six pathologists assessed 50-71 digital slides. We recorded objective magnification, total time, and detection of the following: Mast cells; eosinophils; plasma cells; pigmented macrophages; melanin in the epidermis; fungal bodies; neutrophils; civatte bodies; parakeratosis; and sebocytes. This process was repeated using the corresponding glass slides after 3 weeks. The diagnosis was not required. Results: The mean time to assess digital slides was 176.77 s and 137.61 s for glass slides (P < 0.001, 99% confidence interval [CI]. The mean objective magnification used to detect features using digital slides was 18.28 and 14.07 for glass slides (P < 0.001, 99.99% CI. Parakeratosis, civatte bodies, pigmented macrophages, melanin in the epidermis, mast cells, eosinophils, plasma cells, and neutrophils, were identified at lower objectives on glass slides (P = 0.023-0.001, 95% CI. Average intraobserver concordance ranged from κ = 0.30 to κ = 0.78. Features with poor to fair average concordance were: Melanin in the epidermis (κ = 0.15-0.58; plasma cells (κ = 0.15-0.49; and neutrophils (κ = 0.12-0.48. Features with moderate average intrapathologist concordance were: parakeratosis (κ = 0.21-0.61; civatte bodies (κ = 0.21-0.71; pigment-laden macrophages (κ = 0.34-0.66; mast cells (κ = 0.29-0.78; and eosinophils (κ = 0.31-0.79. The average intrapathologist concordance was good for sebocytes (κ = 0.51-1.00 and fungal bodies (κ = 0.47-0.76. Conclusions: Telepathology using digital slides scanned at ×20 is sufficient for detection of histopathologic features routinely encountered in

  11. Computer aided detection of clusters of microcalcifications on full field digital mammograms

    International Nuclear Information System (INIS)

    Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, H.-P.; Wei Jun; Helvie, Mark A.; Zhou Chuan

    2006-01-01

    We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from the artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case

  12. Comparative study of the polaroid and digital non-mydriatic cameras in the detection of referrable diabetic retinopathy in Australia.

    Science.gov (United States)

    Phiri, R; Keeffe, J E; Harper, C A; Taylor, H R

    2006-08-01

    To show that the non-mydriatic retinal camera (NMRC) using polaroid film is as effective as the NMRC using digital imaging in detecting referrable retinopathy. A series of patients with diabetes attending the eye out-patients department at the Royal Victorian Eye and Ear Hospital had single-field non-mydriatic fundus photographs taken using first a digital and then a polaroid camera. Dilated 30 degrees seven-field stereo fundus photographs were then taken of each eye as the gold standard. The photographs were graded in a masked fashion. Retinopathy levels were defined using the simplified Wisconsin Grading system. We used the kappa statistics for inter-reader and intrareader agreement and the generalized linear model to derive the odds ratio. There were 196 participants giving 325 undilated retinal photographs. Of these participants 111 (57%) were males. The mean age of the patients was 68.8 years. There were 298 eyes with all three sets of photographs from 154 patients. The digital NMRC had a sensitivity of 86.2%[95% confidence interval (CI) 65.8, 95.3], whilst the polaroid NMRC had a sensitivity of 84.1% (95% CI 65.5, 93.7). The specificities of the two cameras were identical at 71.2% (95% CI 58.8, 81.1). There was no difference in the ability of the polaroid and digital camera to detect referrable retinopathy (odds ratio 1.06, 95% CI 0.80, 1.40, P = 0.68). This study suggests that non-mydriatic retinal photography using polaroid film is as effective as digital imaging in the detection of referrable retinopathy in countries such as the USA and Australia or others that use the same criterion for referral.

  13. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

    Energy Technology Data Exchange (ETDEWEB)

    Miri, Shimasadat [Dept. of Endodontics, School of Dentistry, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Mehrailzadeh, Sandra; Sadri, Donya [School of Dentistry, Islamic Azad University, Tehran (Iran, Islamic Republic of); Motamedi, Mahmood Reza Kalantar [Dept. of Research, School of Dentistry, Isfahan Branch, Islamic Azad University, Isfahan (Iran, Islamic Republic of); Soltani, Parisa [Dental Students Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan (Iran, Islamic Republic of)

    2015-09-15

    This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy.

  14. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

    International Nuclear Information System (INIS)

    Miri, Shimasadat; Mehrailzadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar; Soltani, Parisa

    2015-01-01

    This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy

  15. A method to test the reproducibility and to improve performance of computer-aided detection schemes for digitized mammograms

    International Nuclear Information System (INIS)

    Zheng Bin; Gur, David; Good, Walter F.; Hardesty, Lara A.

    2004-01-01

    The purpose of this study is to develop a new method for assessment of the reproducibility of computer-aided detection (CAD) schemes for digitized mammograms and to evaluate the possibility of using the implemented approach for improving CAD performance. Two thousand digitized mammograms (representing 500 cases) with 300 depicted verified masses were selected in the study. Series of images were generated for each digitized image by resampling after a series of slight image rotations. A CAD scheme developed in our laboratory was applied to all images to detect suspicious mass regions. We evaluated the reproducibility of the scheme using the detection sensitivity and false-positive rates for the original and resampled images. We also explored the possibility of improving CAD performance using three methods of combining results from the original and resampled images, including simple grouping, averaging output scores, and averaging output scores after grouping. The CAD scheme generated a detection score (from 0 to 1) for each identified suspicious region. A region with a detection score >0.5 was considered as positive. The CAD scheme detected 238 masses (79.3% case-based sensitivity) and identified 1093 false-positive regions (average 0.55 per image) in the original image dataset. In eleven repeated tests using original and ten sets of rotated and resampled images, the scheme detected a maximum of 271 masses and identified as many as 2359 false-positive regions. Two hundred and eighteen masses (80.4%) and 618 false-positive regions (26.2%) were detected in all 11 sets of images. Combining detection results improved reproducibility and the overall CAD performance. In the range of an average false-positive detection rate between 0.5 and 1 per image, the sensitivity of the scheme could be increased approximately 5% after averaging the scores of the regions detected in at least four images. At low false-positive rate (e.g., ≤average 0.3 per image), the grouping method

  16. Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs - initial results of a phantom study

    International Nuclear Information System (INIS)

    Georg, C.; Welker, V.; Eidam, H.; Alfke, H.

    2005-01-01

    Purpose: To evaluate the feasibility of aortic stentgraft micromovement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs. Material and Methods: An aortic stentgraft used for demonstration purposes was marked with 10 tantalum markers of 0.8 mm in diameter. The stentgraft was placed on a Plexiglas phantom with 5 tantalum markers of 1 mm in diameter simulating a fixed segment needed for mathematical analysis. In a subsequent step, the stentgraft was placed onto an orthopaedic spine model to simulate in vivo conditions in a next step.Two radiographs taken simultaneously from different angles were used for simulating different stentgraft movement, e.g. translation, angulation, aortic pulsation and migration in the spine model. Movement of the stentgraft markers was analysed using a commercially available digital RSA setup (UmRSA registered 4.1, RSA Biomedical, Umea, Sweden). Results: Our study shows the feasibility of measuring aortic stentgraft movement and changes in stentgraft shape in the submillimeter range using digital roentgen stereophotogrammetric analysis. Translation along the 3 cardinal axes, change in stentgraft shape, simulation of aortic pulsation and simulation of in vivo conditions could be described precisely. Conclusion: Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs is a very promising, precise method. (orig.)

  17. Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

    Directory of Open Access Journals (Sweden)

    Mahdieh Dehghani

    2017-02-01

    Full Text Available Objectives: This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries.Materials and Methods: Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD and photostimulable phosphor plate (PSP receptors and intra-oral films were exposed with 60 and 70 kVp with parallel technique. Two observers interpreted the radiographs twice with a two-week interval using a 5-point scale. Teeth were then serially sectioned in mesiodistal direction and evaluated under a stereomicroscope (gold standard. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.Results: Sensitivity of all three receptors for detection of enamel lesions was low (5.5-44.4% but it was higher for dentin lesions (42.8-62.8%; PSP with 70 kVp and 0.03s exposure time had the highest sensitivity for enamel lesions, but the difference among receptors was not statistically significant (P>0.05. Sensitivity of all three receptors for detection of non-cavitated lesions was lower than that for cavitated lesions; PSP with 60 kVp and 0.07s exposure time had higher sensitivity and lower patient radiation dose for detection of cavitated and non-cavitated lesions, but the difference was not significant (P>0.05.Conclusions: Digital radiography using PSP receptor with 70 kVp is recommended to detect initial enamel caries. For detection of non-cavitated and cavitated dentin caries, PSP with 60 kVp is more appropriate. Change in kVp did not affect the diagnostic accuracy for detection of caries, and type of receptor was a more important factor.Keywords: Dental Caries; Diagnostic Imaging; Radiography, Dental, Digital

  18. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    Science.gov (United States)

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  19. Suspicious amorphous microcalcifications detected on full-field digital mammography: correlation with histopathology

    Directory of Open Access Journals (Sweden)

    Vera Christina Camargo de Siqueira Ferreira

    2018-03-01

    Full Text Available Abstract Objective: To evaluate suspicious amorphous calcifications diagnosed on full-field digital mammography (FFDM and establish correlations with histopathology findings. Materials and Methods: This was a retrospective study of 78 suspicious amorphous calcifications (all classified as BI-RADS® 4 detected on FFDM. Vacuum-assisted breast biopsy (VABB was performed. The histopathological classification of VABB core samples was as follows: pB2 (benign; pB3 (uncertain malignant potential; pB4 (suspicion of malignancy; and pB5 (malignant. Treatment was recommended for pB5 lesions. To rule out malignancy, surgical excision was recommended for pB3 and pB4 lesions. Patients not submitted to surgery were followed for at least 6 months. Results: Among the 78 amorphous calcifications evaluated, the histopathological analysis indicated that 8 (10.3% were malignant/suspicious (6 classified as pB5 and 2 classified as pB4 and 36 (46.2% were benign (classified as pB2. The remaining 34 lesions (43.6% were classified as pB3: 33.3% were precursor lesions (atypical ductal hyperplasia, lobular neoplasia, or flat epithelial atypia and 10.3% were high-risk lesions. For the pB3 lesions, the underestimation rate was zero. Conclusion: The diagnosis of precursor lesions (excluding atypical ductal hyperplasia, which can be pB4 depending on the severity and extent of the lesion should not necessarily be considered indicative of underestimation of malignancy. Suspicious amorphous calcifications correlated more often with precursor lesions than with malignant lesions, at a ratio of 3:1.

  20. Clinical assessment of the effect of digital filtering on the detection of ventricular late potentials

    Directory of Open Access Journals (Sweden)

    P.R. Benchimol-Barbosa

    2002-11-01

    Full Text Available Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40, clinically normal controls, GII (N = 158, subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT, and GIII (N = 23, subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05 for GII and 0.31 for GIII (P = NS]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05. Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

  1. Digital breast tomosynthesis: computer-aided detection of clustered microcalcifications on planar projection images

    International Nuclear Information System (INIS)

    Samala, Ravi K; Chan, Heang-Ping; Lu, Yao; Hadjiiski, Lubomir M; Wei, Jun; Helvie, Mark A

    2014-01-01

    This paper describes a new approach to detect microcalcification clusters (MCs) in digital breast tomosynthesis (DBT) via its planar projection (PPJ) image. With IRB approval, two-view (cranio-caudal and mediolateral oblique views) DBTs of human subject breasts were obtained with a GE GEN2 prototype DBT system that acquires 21 projection angles spanning 60° in 3° increments. A data set of 307 volumes (154 human subjects) was divided by case into independent training (127 with MCs) and test sets (104 with MCs and 76 free of MCs). A simultaneous algebraic reconstruction technique with multiscale bilateral filtering (MSBF) regularization was used to enhance microcalcifications and suppress noise. During the MSBF regularized reconstruction, the DBT volume was separated into high frequency (HF) and low frequency components representing microcalcifications and larger structures. At the final iteration, maximum intensity projection was applied to the regularized HF volume to generate a PPJ image that contained MCs with increased contrast-to-noise ratio (CNR) and reduced search space. High CNR objects in the PPJ image were extracted and labeled as microcalcification candidates. Convolution neural network trained to recognize the image pattern of microcalcifications was used to classify the candidates into true calcifications and tissue structures and artifacts. The remaining microcalcification candidates were grouped into MCs by dynamic conditional clustering based on adaptive CNR threshold and radial distance criteria. False positive (FP) clusters were further reduced using the number of candidates in a cluster, CNR and size of microcalcification candidates. At 85% sensitivity an FP rate of 0.71 and 0.54 was achieved for view- and case-based sensitivity, respectively, compared to 2.16 and 0.85 achieved in DBT. The improvement was significant (p-value = 0.003) by JAFROC analysis. (paper)

  2. Equalization and detection for digital communication over nonlinear bandlimited satellite communication channels. Ph.D. Thesis

    Science.gov (United States)

    Gutierrez, Alberto, Jr.

    1995-01-01

    This dissertation evaluates receiver-based methods for mitigating the effects due to nonlinear bandlimited signal distortion present in high data rate satellite channels. The effects of the nonlinear bandlimited distortion is illustrated for digitally modulated signals. A lucid development of the low-pass Volterra discrete time model for a nonlinear communication channel is presented. In addition, finite-state machine models are explicitly developed for a nonlinear bandlimited satellite channel. A nonlinear fixed equalizer based on Volterra series has previously been studied for compensation of noiseless signal distortion due to a nonlinear satellite channel. This dissertation studies adaptive Volterra equalizers on a downlink-limited nonlinear bandlimited satellite channel. We employ as figure of merits performance in the mean-square error and probability of error senses. In addition, a receiver consisting of a fractionally-spaced equalizer (FSE) followed by a Volterra equalizer (FSE-Volterra) is found to give improvement beyond that gained by the Volterra equalizer. Significant probability of error performance improvement is found for multilevel modulation schemes. Also, it is found that probability of error improvement is more significant for modulation schemes, constant amplitude and multilevel, which require higher signal to noise ratios (i.e., higher modulation orders) for reliable operation. The maximum likelihood sequence detection (MLSD) receiver for a nonlinear satellite channel, a bank of matched filters followed by a Viterbi detector, serves as a probability of error lower bound for the Volterra and FSE-Volterra equalizers. However, this receiver has not been evaluated for a specific satellite channel. In this work, an MLSD receiver is evaluated for a specific downlink-limited satellite channel. Because of the bank of matched filters, the MLSD receiver may be high in complexity. Consequently, the probability of error performance of a more practical

  3. Exploring Digital Surface Models from Nine Different Sensors for Forest Monitoring and Change Detection

    Directory of Open Access Journals (Sweden)

    Jiaojiao Tian

    2017-03-01

    Full Text Available Digital surface models (DSMs derived from spaceborne and airborne sensors enable the monitoring of the vertical structures for forests in large areas. Nevertheless, due to the lack of an objective performance assessment for this task, it is difficult to select the most appropriate data source for DSM generation. In order to fill this gap, this paper performs change detection analysis including forest decrease and tree growth. The accuracy of the DSMs is evaluated by comparison with measured tree heights from inventory plots (field data. In addition, the DSMs are compared with LiDAR data to perform a pixel-wise quality assessment. DSMs from four different satellite stereo sensors (ALOS/PRISM, Cartosat-1, RapidEye and WorldView-2, one satellite InSAR sensor (TanDEM-X, two aerial stereo camera systems (HRSC and UltraCam and two airborne laser scanning datasets with different point densities are adopted for the comparison. The case study is a complex central European temperate forest close to Traunstein in Bavaria, Germany. As a major experimental result, the quality of the DSM is found to be robust to variations in image resolution, especially when the forest density is high. The forest decrease results confirm that besides aerial photogrammetry data, very high resolution satellite data, such as WorldView-2, can deliver results with comparable quality as the ones derived from LiDAR, followed by TanDEM-X and Cartosat DSMs. The quality of the DSMs derived from ALOS and Rapid-Eye data is lower, but the main changes are still correctly highlighted. Moreover, the vertical tree growth and their relationship with tree height are analyzed. The major tree height in the study site is between 15 and 30 m and the periodic annual increments (PAIs are in the range of 0.30–0.50 m.

  4. Detection of hidden stationary deformations of vibrating surfaces by use of time-averaged digital holographic interferometry.

    Science.gov (United States)

    Demoli, Nazif; Vukicevic, Dalibor

    2004-10-15

    A method of detecting displacements of a surface from its steady-state position to its equilibrium position while it is vibrating has been developed by use of time-average digital holographic interferometry. This method permits extraction of such a hidden deformation by creating two separated systems of interferogram fringes: one corresponding to a time-varying resonantly oscillating optical phase, the other to the stationary phase modification. A mathematical description of the method and illustrative results of experimental verification are presented.

  5. Design of coherent receiver optical front end for unamplified applications.

    Science.gov (United States)

    Zhang, Bo; Malouin, Christian; Schmidt, Theodore J

    2012-01-30

    Advanced modulation schemes together with coherent detection and digital signal processing has enabled the next generation high-bandwidth optical communication systems. One of the key advantages of coherent detection is its superior receiver sensitivity compared to direct detection receivers due to the gain provided by the local oscillator (LO). In unamplified applications, such as metro and edge networks, the ultimate receiver sensitivity is dictated by the amount of shot noise, thermal noise, and the residual beating of the local oscillator with relative intensity noise (LO-RIN). We show that the best sensitivity is achieved when the thermal noise is balanced with the residual LO-RIN beat noise, which results in an optimum LO power. The impact of thermal noise from the transimpedance amplifier (TIA), the RIN from the LO, and the common mode rejection ratio (CMRR) from a balanced photodiode are individually analyzed via analytical models and compared to numerical simulations. The analytical model results match well with those of the numerical simulations, providing a simplified method to quantify the impact of receiver design tradeoffs. For a practical 100 Gb/s integrated coherent receiver with 7% FEC overhead, we show that an optimum receiver sensitivity of -33 dBm can be achieved at GFEC cliff of 8.55E-5 if the LO power is optimized at 11 dBm. We also discuss a potential method to monitor the imperfections of a balanced and integrated coherent receiver.

  6. Extracting subsurface fingerprints using optical coherence tomography

    CSIR Research Space (South Africa)

    Akhoury, SS

    2015-02-01

    Full Text Available Subsurface Fingerprints using Optical Coherence Tomography Sharat Saurabh Akhoury, Luke Nicholas Darlow Modelling and Digital Science, Council for Scientific and Industrial Research, Pretoria, South Africa Abstract Physiologists have found... approach to extract the subsurface fingerprint representation using a high-resolution imaging technology known as Optical Coherence Tomography (OCT). ...

  7. Digital photogrammetry and histomorphometric assessment of the effect of non-coherent light (light-emitting diode) therapy (λ640 ± 20 nm) on the repair of third-degree burns in rats.

    Science.gov (United States)

    Neves, Silvana Maria Véras; Nicolau, Renata Amadei; Filho, Antônio Luiz Martins Maia; Mendes, Lianna Martha Soares; Veloso, Ana Maria

    2014-01-01

    Recent studies have demonstrated the efficacy of coherent light therapy from the red region of the electromagnetic spectrum on the tissue-healing process. This study analysed the effect of non-coherent light therapy (light-emitting diode-LED) with or without silver sulfadiazine (sulpha) on the healing process of third-degree burns. In this study, 72 rats with third-degree burns were randomly divided into six groups (n = 12): Gr1 (control), Gr2 (non-contact LED), Gr3 (contact LED), Gr4 (sulfadiazine), Gr5 (sulfadiazine + non-contact LED) and Gr6 (sulfadiazine + contact LED). The groups treated with LED therapy received treatment every 48 h (λ = 640 ± 20 nm, 110 mW, 16 J/cm(2); 41 s with contact and 680 s without contact). The digital photometric and histomorphometric analyses were conducted after the burn occurred. The combination of sulpha and LED (contact or non-contact) improved the healing of burn wounds. These results demonstrate that the combination of silver sulfadiazine with LED therapy (λ = 640 ± 20 nm, 4 J/cm(2), without contact) improves healing of third-degree burn wounds, significantly reduces the lesion area and increases the granulation tissue, increases the number of fibroblasts, promotes collagen synthesis and prevents burn infections by accelerating recovery.

  8. Deep learning approach for the detection and quantification of intraretinal cystoid fluid in multivendor optical coherence tomography

    Science.gov (United States)

    Venhuizen, Freerk G.; van Ginneken, Bram; Liefers, Bart; van Asten, Freekje; Schreur, Vivian; Fauser, Sascha; Hoyng, Carel; Theelen, Thomas; Sánchez, Clara I.

    2018-01-01

    We developed a deep learning algorithm for the automatic segmentation and quantification of intraretinal cystoid fluid (IRC) in spectral domain optical coherence tomography (SD-OCT) volumes independent of the device used for acquisition. A cascade of neural networks was introduced to include prior information on the retinal anatomy, boosting performance significantly. The proposed algorithm approached human performance reaching an overall Dice coefficient of 0.754 ± 0.136 and an intraclass correlation coefficient of 0.936, for the task of IRC segmentation and quantification, respectively. The proposed method allows for fast quantitative IRC volume measurements that can be used to improve patient care, reduce costs, and allow fast and reliable analysis in large population studies. PMID:29675301

  9. Adaptive thresholding and dynamic windowing method for automatic centroid detection of digital Shack-Hartmann wavefront sensor

    International Nuclear Information System (INIS)

    Yin Xiaoming; Li Xiang; Zhao Liping; Fang Zhongping

    2009-01-01

    A Shack-Hartmann wavefront sensor (SWHS) splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. The accuracy of the centroid measurement determines the accuracy of the SWHS. Many methods have been presented to improve the accuracy of the wavefront centroid measurement. However, most of these methods are discussed from the point of view of optics, based on the assumption that the spot intensity of the SHWS has a Gaussian distribution, which is not applicable to the digital SHWS. In this paper, we present a centroid measurement algorithm based on the adaptive thresholding and dynamic windowing method by utilizing image processing techniques for practical application of the digital SHWS in surface profile measurement. The method can detect the centroid of each focal spot precisely and robustly by eliminating the influence of various noises, such as diffraction of the digital SHWS, unevenness and instability of the light source, as well as deviation between the centroid of the focal spot and the center of the detection area. The experimental results demonstrate that the algorithm has better precision, repeatability, and stability compared with other commonly used centroid methods, such as the statistical averaging, thresholding, and windowing algorithms.

  10. Detection of epidermal growth factor receptor mutation in lung cancer by droplet digital polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Xu Q

    2015-06-01

    Full Text Available Qing Xu,1,* Yazhen Zhu,2,* Yali Bai,1 Xiumin Wei,1 Xirun Zheng,2 Mao Mao,1 Guangjuan Zheng21Translational Bioscience and Diagnostics, WuXi AppTec, Shanghai, 2Department of Pathology, Guangdong Provincial Hospital of TCM, Guangzhou University of Chinese Medicine, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou, People’s Republic of China*These authors contributed equally to this workBackground: Two types of epidermal growth factor receptor (EGFR mutations in exon 19 and exon 21 (ex19del and L858R are prevalent in lung cancer patients and sensitive to targeted EGFR inhibition. A resistance mutation in exon 20 (T790M has been found to accompany drug treatment when patients relapse. These three mutations are valuable companion diagnostic biomarkers for guiding personalized treatment. Quantitative polymerase chain reaction (qPCR-based methods have been widely used in the clinic by physicians to guide treatment decisions. The aim of this study was to evaluate the technical and clinical sensitivity and specificity of the droplet digital polymerase chain reaction (ddPCR method in detecting the three EGFR mutations in patients with lung cancer.Methods: Genomic DNA from H1975 and PC-9 cells, as well as 92 normal human blood specimens, was used to determine the technical sensitivity and specificity of the ddPCR assays. Genomic DNA of formalin-fixed, paraffin-embedded specimens from 78 Chinese patients with lung adenocarcinoma were assayed using both qPCR and ddPCR.Results: The three ddPCR assays had a limit of detection of 0.02% and a wide dynamic range from 1 to 20,000 copies measurement. The L858R and ex19del assays had a 0% background level in the technical and clinical settings. The T790M assay appeared to have a 0.03% technical background. The ddPCR assays were robust for correct determination of EGFR mutation status in patients, and the dynamic range appeared to be better than qPCR methods. The ddPCR assay for T790M could detect

  11. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    Digital breast tomosynthesis (DBT) strives to overcome the obstacles presented in conventional 2D mammography by taking multiple projections over a fixed angle and reconstructing volumetric data isolates overlying anatomy...

  12. Detection of SEA-type α-thalassemia in embryo biopsies by digital PCR

    Directory of Open Access Journals (Sweden)

    Ta-Hsien Lee

    2017-08-01

    Conclusion: The SEA-type deletion in cultured embryos can be sensitively diagnosed with the digital PCR procedure in clinics. The adoption of this robust PGD method could prevent the implantation of IVF embryos that are destined to develop Bart's hydrops fetalis in a timely manner. The results also help inform future development of a standard digital PCR procedure for cost-effective PGD of α-thalassemia in a standard IVF clinic.

  13. Model observer for assessing digital breast tomosynthesis for multi-lesion detection in the presence of anatomical noise

    Science.gov (United States)

    Wen, Gezheng; Markey, Mia K.; Miner Haygood, Tamara; Park, Subok

    2018-02-01

    Model observers are widely used in task-based assessments of medical image quality. The presence of multiple abnormalities in a single set of images, such as in multifocal multicentric breast cancer (MFMC), has an immense clinical impact on treatment planning and survival outcomes. Detecting multiple breast tumors is challenging as MFMC is relatively uncommon, and human observers do not know the number or locations of tumors a priori. Digital breast tomosynthesis (DBT), in which an x-ray beam sweeps over a limited angular range across the breast, has the potential to improve the detection of multiple tumors. However, prior studies of DBT image quality all focus on unifocal breast cancers. In this study, we extended our 2D multi-lesion (ML) channelized Hotelling observer (CHO) into a 3D ML-CHO that detects multiple lesions from volumetric imaging data. Then we employed the 3D ML-CHO to identify optimal DBT acquisition geometries for detection of MFMC. Digital breast phantoms with multiple embedded synthetic lesions were scanned by simulated DBT scanners of different geometries (wide/narrow angular span, different number of projections per scan) to simulate MFMC cases. With new implementations of 3D partial least squares (PLS) and modified Laguerre-Gauss (LG) channels, the 3D ML-CHO made detection decisions based upon the overall information from individual DBT slices and their correlations. Our evaluation results show that: (1) the 3D ML-CHO could achieve good detection performance with a small number of channels, and 3D PLS channels on average outperform the counterpart LG channels; (2) incorporating locally varying anatomical backgrounds and their correlations as in the 3D ML-CHO is essential for multi-lesion detection; (3) the most effective DBT geometry for detection of MFMC may vary when the task of clinical interest changes, and a given DBT geometry may not yield images that are equally informative for detecting MF, MC, and unifocal cancers.

  14. Fully Automated Robust System to Detect Retinal Edema, Central Serous Chorioretinopathy, and Age Related Macular Degeneration from Optical Coherence Tomography Images

    Directory of Open Access Journals (Sweden)

    Samina Khalid

    2017-01-01

    Full Text Available Maculopathy is the excessive damage to macula that leads to blindness. It mostly occurs due to retinal edema (RE, central serous chorioretinopathy (CSCR, or age related macular degeneration (ARMD. Optical coherence tomography (OCT imaging is the latest eye testing technique that can detect these syndromes in early stages. Many researchers have used OCT images to detect retinal abnormalities. However, to the best of our knowledge, no research that presents a fully automated system to detect all of these macular syndromes is reported. This paper presents the world’s first ever decision support system to automatically detect RE, CSCR, and ARMD retinal pathologies and healthy retina from OCT images. The automated disease diagnosis in our proposed system is based on multilayered support vector machines (SVM classifier trained on 40 labeled OCT scans (10 healthy, 10 RE, 10 CSCR, and 10 ARMD. After training, SVM forms an accurate decision about the type of retinal pathology using 9 extracted features. We have tested our proposed system on 2819 OCT scans (1437 healthy, 640 RE, and 742 CSCR of 502 patients from two different datasets and our proposed system correctly diagnosed 2817/2819 subjects with the accuracy, sensitivity, and specificity ratings of 99.92%, 100%, and 99.86%, respectively.

  15. Radiography and digital image processing for detection of internal breakdown in fruits of mango tree (Mangifera indica L.)

    International Nuclear Information System (INIS)

    Ferreira, Rubemar de Souza

    2004-01-01

    This work proposes a methodology aimed to be an adviser system for detection of internal breakdown in mangoes during the post-harvest phase to packinghouses. It was arranged a set-up to product digital images from X-ray spectrum in the range of 18 and 20 keV, where the primary images acquired were tested by a digital image processing routine for differentiation of seed, pulp, peel and injured zones. The analysis ROC applied to a only cut on a sample of 114 primary images generated, showed that digital image processing routine was able to identify 88% of true-positive injuries and 7% of false-negatives. When tested against the absence of injuries, the DIP routine had identified 22 % of false-positives and 88% of true-negatives. Besides, a cognitive analysis was applied to a sample of 76 digital images of mangoes. Results showed that the images offer enough information for dichotomic interpretation about the main injuries in the fruit, including those of difficult diagnosis under destructive assay. Measurements of observer agreement, performed on the same group of readers showed themselves in the range of fair and substantial strength of agreement. (author)

  16. Use of Digital Rectal Examination as an Adjunct to Prostate Specific Antigen in the Detection of Clinically Significant Prostate Cancer.

    Science.gov (United States)

    Halpern, Joshua A; Oromendia, Clara; Shoag, Jonathan E; Mittal, Sameer; Cosiano, Michael F; Ballman, Karla V; Vickers, Andrew J; Hu, Jim C

    2018-04-01

    Guidelines from the NCCN ® (National Comprehensive Cancer Network®) advocate digital rectal examination screening only in men with elevated prostate specific antigen. We investigated the effect of prostate specific antigen on the association of digital rectal examination and clinically significant prostate cancer in a large American cohort. We evaluated the records of the 35,350 men who underwent digital rectal examination in the screening arm of the Prostate, Lung, Colorectal and Ovarian Cancer Screening trial for the development of clinically significant prostate cancer (Gleason 7 or greater). Followup was 343,273 person-years. The primary outcome was the rate of clinically significant prostate cancer among men with vs without suspicious digital rectal examination. We performed competing risks regression to evaluate the interaction between time varying suspicious digital rectal examination and prostate specific antigen. A total of 1,713 clinically significant prostate cancers were detected with a 10-year cumulative incidence of 5.9% (95% CI 5.6-6.2). Higher risk was seen for suspicious vs nonsuspicious digital rectal examination. Increases in absolute risk were small and clinically irrelevant for normal (less than 2 ng/ml) prostate specific antigen (1.5% vs 0.7% risk of clinically significant prostate cancer at 10 years), clinically relevant for elevated (3 ng/ml or greater) prostate specific antigen (23.0% vs 13.7%) and modestly clinically relevant for equivocal (2 to 3 ng/ml) prostate specific antigen (6.5% vs 3.5%). Digital rectal examination demonstrated prognostic usefulness when prostate specific antigen was greater than 3 ng/ml, limited usefulness for less than 2 ng/ml and marginal usefulness for 2 to 3 ng/ml. These findings support the restriction of digital rectal examination to men with higher prostate specific antigen as a reflex test to improve specificity. It should not be used as a primary screening modality to improve sensitivity. Copyright

  17. Polarization-multiplexed rate-adaptive non-binary-quasi-cyclic-LDPC-coded multilevel modulation with coherent detection for optical transport networks.

    Science.gov (United States)

    Arabaci, Murat; Djordjevic, Ivan B; Saunders, Ross; Marcoccia, Roberto M

    2010-02-01

    In order to achieve high-speed transmission over optical transport networks (OTNs) and maximize its throughput, we propose using a rate-adaptive polarization-multiplexed coded multilevel modulation with coherent detection based on component non-binary quasi-cyclic (QC) LDPC codes. Compared to prior-art bit-interleaved LDPC-coded modulation (BI-LDPC-CM) scheme, the proposed non-binary LDPC-coded modulation (NB-LDPC-CM) scheme not only reduces latency due to symbol- instead of bit-level processing but also provides either impressive reduction in computational complexity or striking improvements in coding gain depending on the constellation size. As the paper presents, compared to its prior-art binary counterpart, the proposed NB-LDPC-CM scheme addresses the needs of future OTNs, which are achieving the target BER performance and providing maximum possible throughput both over the entire lifetime of the OTN, better.

  18. Noncontact measurement of elasticity for the detection of soft-tissue tumors using phase-sensitive optical coherence tomography combined with a focused air-puff system.

    Science.gov (United States)

    Wang, Shang; Li, Jiasong; Manapuram, Ravi Kiran; Menodiado, Floredes M; Ingram, Davis R; Twa, Michael D; Lazar, Alexander J; Lev, Dina C; Pollock, Raphael E; Larin, Kirill V

    2012-12-15

    We report on an optical noncontact method for the detection of soft-tissue tumors based on the measurement of their elasticity. A focused air-puff system is used to excite surface waves (SWs) on soft tissues with transient static pressure. A high-speed phase-sensitive optical coherence tomography system is used to measure the SWs as they propagate from the point of excitation. To evaluate the stiffness of soft tissues, the Young's modulus is quantified based on the group velocity of SWs. Pilot experiments were performed on ex vivo human myxoma and normal fat. Results demonstrate the feasibility of the proposed method to measure elasticity and differentiate soft-tissue tumors from normal tissues.

  19. Accuracy of digital radiography and cone beam computed tomography on periapical radiolucency detection in endodontically treated teeth.

    Science.gov (United States)

    Venskutonis, Tadas; Daugela, Povilas; Strazdas, Marijus; Juodzbalys, Gintaras

    2014-04-01

    The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images) from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women) a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible) were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42) and radiographic (n = 24) examinations (P cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  20. COHERENT Experiment: current status

    International Nuclear Information System (INIS)

    Akimov, D; Belov, V; Bolozdynya, A; Burenkov, A; Albert, J B; Del Valle Coello, M; D’Onofrio, M; Awe, C; Barbeau, P S; Cervantes, M; Becker, B; Cabrera-Palmer, B; Collar, J I; Cooper, R J; Cooper, R L; Cuesta, C; Detwiler, J; Eberhardt, A; Dean, D; Dolgolenko, A G

    2017-01-01

    The COHERENT Collaboration is realizing a long term neutrino physics research program. The main goals of the program are to detect and study elastic neutrino-nucleus scattering (CEνNS). This process is predicted by Standard Model but it has never been observed experimentally because of the very low energy of the recoil nucleus. COHERENT is using different detector technologies: CsI[Na] and NaI scintillator crystals, a single-phase liquid Ar and a Ge detectors. The placement of all the detector setups is in the basement of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The current status of the COHERENT experimental program is presented. (paper)

  1. Detecting the transport barriers in the Pearl River estuary, Southern China with the aid of Lagrangian coherent structures

    Science.gov (United States)

    Wei, Xing; Zhan, Haigang; Cai, Shuqun; Zhan, Weikang; Ni, Peitong

    2018-05-01

    Knowledge of horizontal transport pathways is important for the protection of the marine ecosystem in coastal areas. In this paper, we develop a 3D model to simulate hydrodynamics and particle transport in the Pearl River Estuary (PRE), Southern China, to study the barriers to transport in the PRE. Specifically, we use the flow velocity produced by the model to locate Lagrangian coherent structures (LCSs) hidden in ocean surface currents. Our findings show that a remarkable LCS begins upstream near the Humen inlet, extends to the Wanshan Islands via Neilingding Island, and can act as a transport barrier in the estuary. This LCS appeared 1-2 h after high tide and was persistent for 6-7 h during every ebb tide. Particles released on the west side of the LCS moved downstream, exited the estuary by Daxi Channel, and seldom spread to the east side, especially the Hong Kong Sea area. An analysis of several scenarios suggested that the formation of this LCS was due to topography restrictions and tidal forces.

  2. Value of digital radiography in expiration in detection of pneumothorax; Wertigkeit der digitalen Roentgenaufnahme in Exspiration zum Nachweis eines Pneumothorax

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D. [Asklepios Klinik St. Georg, Hamburg (Germany). Dept. of Radiology; Schulz, U. [medistat GmbH, Kiel (Germany). Medical Statistics

    2014-03-15

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  3. Comparison of the analog and digital pulse-shaping methods in signal processing in nuclear detections

    International Nuclear Information System (INIS)

    Golnabi, H.

    2002-01-01

    The goal of this article is to describe the potential applications of the new improved digital techniques and provide a meaningful figure of merit for the comparison of the analog and digital methods. The experimental operation of a typical digital pulse shaper used in a spectrometer with the 23 Na source and a Ge y-ray detector is discussed. The effect of different imposed dead time on the counted pulses is investigated. It is noticed that nuclear events distribution in all ranges of dead time does not obey Poisson's law and deviation from this distribution depends on the counting rate. For a given dead time, deviation from this distribution increases linearly by increasing imposed dead time. For a fixed dead time, when counting rate increases deviation from Poisson's distribution law increases accordingly, and vice versa. (Author)

  4. Developing Dynamic Digital Image Techniques with Continuous Parameters to Detect Structural Damage

    Directory of Open Access Journals (Sweden)

    Ming-Hsiang Shih

    2013-01-01

    Full Text Available Several earthquakes with strong magnitude occurred globally at various locations, especially the unforgettable tsunami disaster caused by the earthquake in Indonesia and Japan. If the characteristics of structures can be well understood to implement new technology, the damages caused by most natural disasters can be significantly alleviated. In this research, dynamic digital image correlation method for using continuous parameter is applied for developing a low-cost digital image correlation coefficient method with advanced digital cameras and high-speed computers. The experimental study using cantilever test object with defect control confirms that the vibration mode calculated using this proposed method can highly express the defect locations. This proposed method combined with the sensitivity of Inter-Story Drift Mode Shape, IDMS, can also reveal the damage degree of damage structure. These test and analysis results indicate that this proposed method is high enough for applying to achieve the object of real-time online monitoring of structure.

  5. A Digital App to Aid Detection, Monitoring, and Management of Dyslexia in Young Children (DIMMAND): Protocol for a Digital Health and Education Solution.

    Science.gov (United States)

    Sood, Mariam R; Toornstra, Annet; Sereno, Martin I; Boland, Mark; Filaretti, Daniele; Sood, Anuj

    2018-05-17

    Dyslexia, a specific learning difficulty and a disability as defined in the Equality Act 2010, is a lifelong condition that affects a child from the start of education. Dyslexia is characterized by difficulties in language processing (reading, spelling, and writing) which do not correspond with the child's general intellectual abilities. Although dyslexia cannot be cured, there is a consensus that interventions are more effective and have greater impact the earlier they are administered. Effective interventions start with diagnosis. Currently, formal diagnosis requires an assessment by a dyslexia specialist or educational psychologist. These assessments are expensive and are not easy for a non-specialist teacher or parent to interpret. Consequently, formal assessments are normally performed at a much later age, when interventions are less likely to be effective. Combining the latest in scientific research, expertise of dyslexia practitioners and real-time interactivity facilitated by digital technologies, we aim to provide a cost-effective and convenient solution that focuses on early dyslexia detection and management. We discuss the rationale and protocol for the design and development of a digital health solution aimed at improving the early detection, monitoring and management of dyslexia (DIMMAND) in young children (4-8 years). The primary objective is to create a game-based digital solution aimed at children, parents, and teachers that firstly assesses, then monitors and manages progress in a convenient, cost-effective and private environment. The proposed solution will be designed and developed in phases. In the initial phase, the full functional specification of the games that constitute the app will be designed, together with the overall architecture of the solution. Prototype proof-of-concept implementation for few of these games, and commercialization strategies will also be developed. The follow-on phases will see the design implemented into a validated

  6. Detecting agricultural to urban land use change from multi-temporal MSS digital data. [Salt Lake County, Utah

    Science.gov (United States)

    Ridd, M. K.; Merola, J. A.; Jaynes, R. A.

    1983-01-01

    Conversion of agricultural land to a variety of urban uses is a major problem along the Wasatch Front, Utah. Although LANDSAT MSS data is a relatively coarse tool for discriminating categories of change in urban-size plots, its availability prompts a thorough test of its power to detect change. The procedures being applied to a test area in Salt Lake County, Utah, where the land conversion problem is acute are presented. The identity of land uses before and after conversion was determined and digital procedures for doing so were compared. Several algorithms were compared, utilizing both raw data and preprocessed data. Verification of results involved high quality color infrared photography and field observation. Two data sets were digitally registered, specific change categories internally identified in the software, results tabulated by computer, and change maps printed at 1:24,000 scale.

  7. Determining the Effect of Calculus, Hypocalcification, and Stain on Using Optical Coherence Tomography and Polarized Raman Spectroscopy for Detecting White Spot Lesions

    Directory of Open Access Journals (Sweden)

    Amanda Huminicki

    2010-01-01

    Full Text Available Optical coherence tomography (OCT and polarized Raman spectroscopy (PRS have been shown as useful methods for distinguishing sound enamel from carious lesions ex vivo. However, factors in the oral environment such as calculus, hypocalcification, and stain could lead to false-positive results. OCT and PRS were used to investigate extracted human teeth clinically examined for sound enamel, white spot lesion (WSL, calculus, hypocalcification, and stain to determine whether these factors would confound WSL detection with these optical methods. Results indicate that OCT allowed differentiating caries from sound enamel, hypocalcification, and stain, with calculus deposits recognizable on OCT images. ANOVA and post-hoc unequal N HSD analyses to compare the mean Raman depolarization ratios from the various groups showed that the mean values were statistically significant at P<.05, except for several comparison pairs. With the current PRS analysis method, the mean depolarization ratios of stained enamel and caries are not significantly different due to the sloping background in the stained enamel spectra. Overall, calculus and hypocalcification are not confounding factors affecting WSL detection using OCT and PRS. Stain does not influence WSL detection with OCT. Improved PRS analysis methods are needed to differentiate carious from stained enamel.

  8. Spatial recurrence analysis: A sensitive and fast detection tool in digital mammography

    International Nuclear Information System (INIS)

    Prado, T. L.; Galuzio, P. P.; Lopes, S. R.; Viana, R. L.

    2014-01-01

    Efficient diagnostics of breast cancer requires fast digital mammographic image processing. Many breast lesions, both benign and malignant, are barely visible to the untrained eye and requires accurate and reliable methods of image processing. We propose a new method of digital mammographic image analysis that meets both needs. It uses the concept of spatial recurrence as the basis of a spatial recurrence quantification analysis, which is the spatial extension of the well-known time recurrence analysis. The recurrence-based quantifiers are able to evidence breast lesions in a way as good as the best standard image processing methods available, but with a better control over the spurious fragments in the image

  9. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  10. Digital Holographic Microscopy, a Method for Detection of Microorganisms in Plume Samples from Enceladus and Other Icy Worlds.

    Science.gov (United States)

    Bedrossian, Manuel; Lindensmith, Chris; Nadeau, Jay L

    2017-09-01

    Detection of extant microbial life on Earth and elsewhere in the Solar System requires the ability to identify and enumerate micrometer-scale, essentially featureless cells. On Earth, bacteria are usually enumerated by culture plating or epifluorescence microscopy. Culture plates require long incubation times and can only count culturable strains, and epifluorescence microscopy requires extensive staining and concentration of the sample and instrumentation that is not readily miniaturized for space. Digital holographic microscopy (DHM) represents an alternative technique with no moving parts and higher throughput than traditional microscopy, making it potentially useful in space for detection of extant microorganisms provided that sufficient numbers of cells can be collected. Because sample collection is expected to be the limiting factor for space missions, especially to outer planets, it is important to quantify the limits of detection of any proposed technique for extant life detection. Here we use both laboratory and field samples to measure the limits of detection of an off-axis digital holographic microscope (DHM). A statistical model is used to estimate any instrument's probability of detection at various bacterial concentrations based on the optical performance characteristics of the instrument, as well as estimate the confidence interval of detection. This statistical model agrees well with the limit of detection of 10 3 cells/mL that was found experimentally with laboratory samples. In environmental samples, active cells were immediately evident at concentrations of 10 4 cells/mL. Published estimates of cell densities for Enceladus plumes yield up to 10 4 cells/mL, which are well within the off-axis DHM's limits of detection to confidence intervals greater than or equal to 95%, assuming sufficient sample volumes can be collected. The quantitative phase imaging provided by DHM allowed minerals to be distinguished from cells. Off-axis DHM's ability for

  11. Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease.

    Science.gov (United States)

    Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea

    2015-12-01

    Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP). Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed. Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD. PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Silencing of the Drosophila ortholog of SOX5 in heart leads to cardiac dysfunction as detected by optical coherence tomography.

    Science.gov (United States)

    Li, Airong; Ahsen, Osman O; Liu, Jonathan J; Du, Chuang; McKee, Mary L; Yang, Yan; Wasco, Wilma; Newton-Cheh, Christopher H; O'Donnell, Christopher J; Fujimoto, James G; Zhou, Chao; Tanzi, Rudolph E

    2013-09-15

    The SRY-related HMG-box 5 (SOX5) gene encodes a member of the SOX family of transcription factors. Recently, genome-wide association studies have implicated SOX5 as a candidate gene for susceptibility to four cardiac-related endophenotypes: higher resting heart rate (HR), the electrocardiographic PR interval, atrial fibrillation and left ventricular mass. We have determined that human SOX5 has a highly conserved Drosophila ortholog, Sox102F, and have employed transgenic Drosophila models to quantitatively measure cardiac function in adult flies. For this purpose, we have developed a high-speed and ultrahigh-resolution optical coherence tomography imaging system, which enables rapid cross-sectional imaging of the heart tube over various cardiac cycles for the measurement of cardiac structural and dynamical parameters such as HR, dimensions and areas of heart chambers, cardiac wall thickness and wall velocities. We have found that the silencing of Sox102F resulted in a significant decrease in HR, heart chamber size and cardiac wall velocities, and a significant increase in cardiac wall thickness that was accompanied by disrupted myofibril structure in adult flies. In addition, the silencing of Sox102F in the wing led to increased L2, L3 and wing marginal veins and increased and disorganized expression of wingless, the central component of the Wnt signaling pathway. Collectively, the silencing of Sox102F resulted in severe cardiac dysfunction and structural defects with disrupted Wnt signaling transduction in flies. This implicates an important functional role for SOX5 in heart and suggests that the alterations in SOX5 levels may contribute to the pathogenesis of multiple cardiac diseases or traits.

  13. Contrast enhanced digital mammography: Is it useful in detecting lesions in edematous breast?

    Directory of Open Access Journals (Sweden)

    Noha Abd ElShafy ElSaid

    2015-09-01

    Conclusion: Dual-energy contrast-enhanced digital mammography is a useful technique in identification of lesions in mammographically dense edematous breasts and proved to be a useful tool in the follow-up of cases presenting by edema after conservative breast surgery and chemotherapy.

  14. Detection of tuberculosis patterns in digital photographs of chest X-ray images using Deep Learning: feasibility study.

    Science.gov (United States)

    Becker, A S; Blüthgen, C; Phi van, V D; Sekaggya-Wiltshire, C; Castelnuovo, B; Kambugu, A; Fehr, J; Frauenfelder, T

    2018-03-01

    To evaluate the feasibility of Deep Learning-based detection and classification of pathological patterns in a set of digital photographs of chest X-ray (CXR) images of tuberculosis (TB) patients. In this prospective, observational study, patients with previously diagnosed TB were enrolled. Photographs of their CXRs were taken using a consumer-grade digital still camera. The images were stratified by pathological patterns into classes: cavity, consolidation, effusion, interstitial changes, miliary pattern or normal examination. Image analysis was performed with commercially available Deep Learning software in two steps. Pathological areas were first localised; detected areas were then classified. Detection was assessed using receiver operating characteristics (ROC) analysis, and classification using a confusion matrix. The study cohort was 138 patients with human immunodeficiency virus (HIV) and TB co-infection (median age 34 years, IQR 28-40); 54 patients were female. Localisation of pathological areas was excellent (area under the ROC curve 0.82). The software could perfectly distinguish pleural effusions from intraparenchymal changes. The most frequent misclassifications were consolidations as cavitations, and miliary patterns as interstitial patterns (and vice versa). Deep Learning analysis of CXR photographs is a promising tool. Further efforts are needed to build larger, high-quality data sets to achieve better diagnostic performance.

  15. Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening

    Science.gov (United States)

    Weinstein, Susan P.; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Digital breast tomosynthesis (DBT) represents a valuable addition to breast cancer screening by decreasing recall rates while increasing cancer detection rates. The increased accuracy achieved with DBT is due to the quasi–three-dimensional format of the reconstructed images and the ability to “scroll through” breast tissue in the reconstructed images, thereby reducing the effect of tissue superimposition found with conventional planar digital mammography. The margins of both benign and malignant lesions are more conspicuous at DBT, which allows improved lesion characterization, increased reader confidence, and improved screening outcomes. However, even with the improvements in accuracy achieved with DBT, there remain differences in breast cancer conspicuity by mammographic view. Early data suggest that breast cancers may be more conspicuous on craniocaudal (CC) views than on mediolateral oblique (MLO) views. While some very laterally located breast cancers may be visualized on only the MLO view, the increased conspicuity of cancers on the CC view compared with the MLO view suggests that DBT screening should be performed with two-view imaging. Even with the improved conspicuity of lesions at DBT, there may still be false-negative studies. Subtle lesions seen on only one view may be discounted, and dense and/or complex tissue patterns may make some cancers occult or extremely difficult to detect. Therefore, radiologists should be cognizant of both perceptual and cognitive errors to avoid potential pitfalls in lesion detection and characterization. ©RSNA, 2016 Online supplemental material is available for this article. PMID:27715711

  16. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Radu, Maria D; Räber, Lorenz; Heo, Jungho

    2014-01-01

    history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS...

  17. Reduced complexity digital back-propagation methods for optical communication systems

    NARCIS (Netherlands)

    Napoli, A.; Maalej, Z.; Sleiffer, V.A.J.M.; Kuschnerov, M.; Rafique, D.; Timmers, E.; Spinnler, B.; Rahman, T.; Coelho, L.D.; Hanik, N.

    2014-01-01

    Next-generation optical communication systems will continue to push the ( bandwidth $cdot$ distance) product towards its physical limit. To address this enormous demand, the usage of digital signal processing together with advanced modulation formats and coherent detection has been proposed to

  18. Accuracy of Digital Radiography and Cone Beam Computed Tomography on Periapical Radiolucency Detection in Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    Tadas Venskutonis

    2014-07-01

    Full Text Available Objectives: The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Material and Methods: Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. Results: In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42 and radiographic (n = 24 examinations (P < 0.05. In molar teeth, CBCT identify a significantly higher amount of periapical lesions than with the radiographic method (P < 0.05. There were significant differences between CBCT and PR in the mean number of lesions identified per tooth (1.2 vs 0.66, P = 0.03, number of teeth with lesions (0.71 vs 0.46, P = 0.03 and number of lesions identified per canal (0.57 vs 0.33, P = 0.005. Considering CBCT as “gold standard” in lesion detection with the sensitivity, specificity and accuracy considering as score 1, then the same parameters of PR were 0.57, 1 and 0.76 respectively. Conclusions: Within the limitations of the present study, it can be concluded that cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  19. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    International Nuclear Information System (INIS)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung

    2006-01-01

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma

  20. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung [College of Medicine Seoul National University and The Insititute of Radiation Medicine, Seoul National University Research Center, Seoul (Korea, Republic of)

    2006-04-15

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma.

  1. Detection of retinal lesions in diabetic retinopathy: comparative evaluation of 7-field digital color photography versus red-free photography.

    Science.gov (United States)

    Venkatesh, Pradeep; Sharma, Reetika; Vashist, Nagender; Vohra, Rajpal; Garg, Satpal

    2015-10-01

    Red-free light allows better detection of vascular lesions as this wavelength is absorbed by hemoglobin; however, the current gold standard for the detection and grading of diabetic retinopathy remains 7-field color fundus photography. The goal of this study was to compare the ability of 7-field fundus photography using red-free light to detect retinopathy lesions with corresponding images captured using standard 7-field color photography. Non-stereoscopic standard 7-field 30° digital color fundus photography and 7-field 30° digital red-free fundus photography were performed in 200 eyes of 103 patients with various grades of diabetic retinopathy ranging from mild to moderate non-proliferative diabetic retinopathy to proliferative diabetic retinopathy. The color images (n = 1,400) were studied with corresponding red-free images (n = 1,400) by one retina consultant (PV) and two senior residents training in retina. The various retinal lesions [microaneurysms, hemorrhages, hard exudates, soft exudates, intra-retinal microvascular anomalies (IRMA), neovascularization of the retina elsewhere (NVE), and neovascularization of the disc (NVD)] detected by all three observers in each of the photographs were noted followed by determination of agreement scores using κ values (range 0-1). Kappa coefficient was categorized as poor (≤0), slight (0.01-0.20), fair (0.2 -0.40), moderate (0.41-0.60), substantial (0.61-0.80), and almost perfect (0.81-1). The number of lesions detected by red-free images alone was higher for all observers and all abnormalities except hard exudates. Detection of IRMA was especially higher for all observers with red-free images. Between image pairs, there was substantial agreement for detection of hard exudates (average κ = 0.62, range 0.60-0.65) and moderate agreement for detection of hemorrhages (average κ = 0.52, range 0.45-0.58), soft exudates (average κ = 0.51, range 0.42-0.61), NVE (average κ = 0.47, range 0.39-0.53), and NVD

  2. Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography

    Science.gov (United States)

    Cockmartin, L.; Marshall, N. W.; Zhang, G.; Lemmens, K.; Shaheen, E.; Van Ongeval, C.; Fredenberg, E.; Dance, D. R.; Salvagnini, E.; Michielsen, K.; Bosmans, H.

    2017-02-01

    This paper introduces and applies a structured phantom with inserted target objects for the comparison of detection performance of digital breast tomosynthesis (DBT) against 2D full field digital mammography (FFDM). The phantom consists of a 48 mm thick breast-shaped polymethyl methacrylate (PMMA) container filled with water and PMMA spheres of different diameters. Three-dimensionally (3D) printed spiculated masses (diameter range: 3.8-9.7 mm) and non-spiculated masses (1.6-6.2 mm) along with microcalcifications (90-250 µm) were inserted as targets. Reproducibility of the phantom application was studied on a single system using 30 acquisitions. Next, the phantom was evaluated on five different combined FFDM & DBT systems and target detection was compared for FFDM and DBT modes. Ten phantom images in both FFDM and DBT modes were acquired on these 5 systems using automatic exposure control. Five readers evaluated target detectability. Images were read with the four-alternative forced-choice (4-AFC) paradigm, with always one segment including a target and 3 normal background segments. The percentage of correct responses (PC) was assessed based on 10 trials of each reader for each object type, size and imaging modality. Additionally, detection threshold diameters at 62.5 PC were assessed via non-linear regression fitting of the psychometric curve. The reproducibility study showed no significant differences in PC values. Evaluation of target detection in FFDM showed that microcalcification detection thresholds ranged between 110 and 118 µm and were similar compared to the detection in DBT (range of 106-158 µm). In DBT, detection of both mass types increased significantly (p  =  0.0001 and p  =  0.0002 for non-spiculated and spiculated masses respectively) compared to FFDM, achieving almost 100% detection for all spiculated mass diameters. In conclusion, a structured phantom with inserted targets was able to show evidence for detectability

  3. Integrated coherent matter wave circuits

    International Nuclear Information System (INIS)

    Ryu, C.; Boshier, M. G.

    2015-01-01

    An integrated coherent matter wave circuit is a single device, analogous to an integrated optical circuit, in which coherent de Broglie waves are created and then launched into waveguides where they can be switched, divided, recombined, and detected as they propagate. Applications of such circuits include guided atom interferometers, atomtronic circuits, and precisely controlled delivery of atoms. We report experiments demonstrating integrated circuits for guided coherent matter waves. The circuit elements are created with the painted potential technique, a form of time-averaged optical dipole potential in which a rapidly moving, tightly focused laser beam exerts forces on atoms through their electric polarizability. Moreover, the source of coherent matter waves is a Bose-Einstein condensate (BEC). Finally, we launch BECs into painted waveguides that guide them around bends and form switches, phase coherent beamsplitters, and closed circuits. These are the basic elements that are needed to engineer arbitrarily complex matter wave circuitry

  4. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-12-01

    To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.

  5. Coherent laser vision system

    International Nuclear Information System (INIS)

    Sebastion, R.L.

    1995-01-01

    The Coherent Laser Vision System (CLVS) is being developed to provide precision real-time 3D world views to support site characterization and robotic operations and during facilities Decontamination and Decommissioning. Autonomous or semiautonomous robotic operations requires an accurate, up-to-date 3D world view. Existing technologies for real-time 3D imaging, such as AM laser radar, have limited accuracy at significant ranges and have variability in range estimates caused by lighting or surface shading. Recent advances in fiber optic component technology and digital processing components have enabled the development of a new 3D vision system based upon a fiber optic FMCW coherent laser radar. The approach includes a compact scanner with no-moving parts capable of randomly addressing all pixels. The system maintains the immunity to lighting and surface shading conditions which is characteristic to coherent laser radar. The random pixel addressability allows concentration of scanning and processing on the active areas of a scene, as is done by the human eye-brain system

  6. Coherent laser vision system

    Energy Technology Data Exchange (ETDEWEB)

    Sebastion, R.L. [Coleman Research Corp., Springfield, VA (United States)

    1995-10-01

    The Coherent Laser Vision System (CLVS) is being developed to provide precision real-time 3D world views to support site characterization and robotic operations and during facilities Decontamination and Decommissioning. Autonomous or semiautonomous robotic operations requires an accurate, up-to-date 3D world view. Existing technologies for real-time 3D imaging, such as AM laser radar, have limited accuracy at significant ranges and have variability in range estimates caused by lighting or surface shading. Recent advances in fiber optic component technology and digital processing components have enabled the development of a new 3D vision system based upon a fiber optic FMCW coherent laser radar. The approach includes a compact scanner with no-moving parts capable of randomly addressing all pixels. The system maintains the immunity to lighting and surface shading conditions which is characteristic to coherent laser radar. The random pixel addressability allows concentration of scanning and processing on the active areas of a scene, as is done by the human eye-brain system.

  7. Impact on breast cancer diagnosis in a multidisciplinary unit after the incorporation of mammography digitalization and computer-aided detection systems.

    Science.gov (United States)

    Romero, Cristina; Varela, Celia; Muñoz, Enriqueta; Almenar, Asunción; Pinto, Jose María; Botella, Miguel

    2011-12-01

    The purpose of this article is to evaluate the impact on the diagnosis of breast cancer of implementing full-field digital mammography (FFDM) in a multidisciplinary breast pathology unit and, 1 year later, the addition of a computer-aided detection (CAD) system. A total of 13,453 mammograms performed between January and July of the years 2004, 2006, and 2007 were retrospectively reviewed using conventional mammography, digital mammography, and digital mammography plus CAD techniques. Mammograms were classified into two subsets: screening and diagnosis. Variables analyzed included cancer detection rate, rate of in situ carcinoma, tumor size at detection, biopsy rate, and positive predictive value of biopsy. FFDM increased the cancer detection rate, albeit not statistically significantly. The detection rate of in situ carcinoma increased significantly using FFDM plus CAD compared with conventional technique (36.8% vs 6.7%; p = 0.05 without Bonferroni statistical correction) for the screening dataset. Relative to conventional mammography, tumor size at detection decreased with digital mammography (T1, 61.5% vs 88%; p = 0.018) and with digital mammography plus CAD (T1, 79.7%; p = 0.03 without Bonferroni statistical correction). Biopsy rates in the general population increased significantly using CAD (10.6/1000 for conventional mammography, 14.7/1000 for digital mammography, and 17.9/1000 for digital mammography plus CAD; p = 0.02). The positive predictive value of biopsy decreased slightly, but not significantly, for both subsets. The incorporation of new techniques has improved the performance of the breast unit by increasing the overall detection rates and earlier detection (smaller tumors), both leading to an increase in interventionism.

  8. Coherence and Sense of Coherence

    DEFF Research Database (Denmark)

    Dau, Susanne

    2014-01-01

    Constraints in the implementation of models of blended learning can be explained by several causes, but in this paper, it is illustrated that lack of sense of coherence is a major factor of these constraints along with the referential whole of the perceived learning environments. The question exa...

  9. A coherent method for the detection and parameter estimation of continuous gravitational wave signals using a pulsar timing array

    International Nuclear Information System (INIS)

    Wang, Yan; Mohanty, Soumya D.; Jenet, Fredrick A.

    2014-01-01

    The use of a high precision pulsar timing array is a promising approach to detecting gravitational waves in the very low frequency regime (10 –6 -10 –9 Hz) that is complementary to ground-based efforts (e.g., LIGO, Virgo) at high frequencies (∼10-10 3 Hz) and space-based ones (e.g., LISA) at low frequencies (10 –4 -10 –1 Hz). One of the target sources for pulsar timing arrays is individual supermassive black hole binaries which are expected to form in galactic mergers. In this paper, a likelihood-based method for detection and parameter estimation is presented for a monochromatic continuous gravitational wave signal emitted by such a source. The so-called pulsar terms in the signal that arise due to the breakdown of the long-wavelength approximation are explicitly taken into account in this method. In addition, the method accounts for equality and inequality constraints involved in the semi-analytical maximization of the likelihood over a subset of the parameters. The remaining parameters are maximized over numerically using Particle Swarm Optimization. Thus, the method presented here solves the monochromatic continuous wave detection and parameter estimation problem without invoking some of the approximations that have been used in earlier studies.

  10. A coherent method for the detection and parameter estimation of continuous gravitational wave signals using a pulsar timing array

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan; Mohanty, Soumya D.; Jenet, Fredrick A. [Department of Physics and Astronomy, University of Texas at Brownsville, 1 West University Boulevard, Brownsville, TX 78520 (United States)

    2014-11-01

    The use of a high precision pulsar timing array is a promising approach to detecting gravitational waves in the very low frequency regime (10{sup –6}-10{sup –9} Hz) that is complementary to ground-based efforts (e.g., LIGO, Virgo) at high frequencies (∼10-10{sup 3} Hz) and space-based ones (e.g., LISA) at low frequencies (10{sup –4}-10{sup –1} Hz). One of the target sources for pulsar timing arrays is individual supermassive black hole binaries which are expected to form in galactic mergers. In this paper, a likelihood-based method for detection and parameter estimation is presented for a monochromatic continuous gravitational wave signal emitted by such a source. The so-called pulsar terms in the signal that arise due to the breakdown of the long-wavelength approximation are explicitly taken into account in this method. In addition, the method accounts for equality and inequality constraints involved in the semi-analytical maximization of the likelihood over a subset of the parameters. The remaining parameters are maximized over numerically using Particle Swarm Optimization. Thus, the method presented here solves the monochromatic continuous wave detection and parameter estimation problem without invoking some of the approximations that have been used in earlier studies.

  11. Detection of newly produced T and B lymphocytes by digital PCR in blood stored dry on nylon flocked swabs.

    Science.gov (United States)

    Tessitore, Marion Vaglio; Sottini, Alessandra; Roccaro, Aldo M; Ghidini, Claudia; Bernardi, Simona; Martellosio, Giovanni; Serana, Federico; Imberti, Luisa

    2017-04-05

    A normal number of T-cell receptor excision circles (TRECs) and K-deleting recombination excision circles (KRECs) is considered a biomarker for adequate new T- and B-cell production. In newborns, detection of TRECs and KRECs by real time PCR from dried blood spotted on filter paper is used for the screening of severe immunodeficiency. In adults, elderly and during diseases, where the number of TRECs is lower than in newborns and children, a large amount of DNA and a sensitive method of amplification are necessary to identify newly produced lymphocytes. DNA was prepared from blood of 203 healthy adults (range: 18-91 years old) absorbed for 10 s on flocked swabs and let to dry, or from peripheral blood mononuclear cells. DNA was subjected to digital PCR and to well established conventional real time PCR-based method using TREC- and KREC-specific primers and probes. The number of TRECs and KRECs was expressed per mL of blood. Statistical analysis was performed by nested ANOVA, Pearson coefficient of determination, and by linear regression tests. The novel method for the storage of dried blood on nylon flocked swabs and the use of digital PCR allow quantification of TRECs and KRECs with high degree of sensitivity, specificity, accuracy, and precision. TRECs and KRECs were amplified by digital PCR in all tested blood samples, including those obtained from elderly individuals (>70 years old) and that were negative by real time PCR. Furthermore, values of TRECs and KRECs obtained by digital PCR were in the range of those acquired by real time PCR. Our findings demonstrate that DNA isolation from dried blood on flocked swabs followed by digital PCR-based analysis represents a useful tool for studying new lymphocyte production in adults and elderly individuals. This suggests the potential use of the methodology when monitoring of clinical variables is limited by the number of molecules that can be amplified and detected, such as in patients with immunodeficiency or under

  12. Digital camera image analysis of faeces in detection of cholestatic jaundice in infants

    OpenAIRE

    Parinya Parinyanut; Tai Bandisak; Piyawan Chiengkriwate; Sawit Tanthanuch; Surasak Sangkhathat

    2016-01-01

    Background: Stool colour assessment is a screening method for biliary tract obstruction in infants. This study is aimed to be a proof of concept work of digital photograph image analysis of stool colour compared to colour grading by a colour card, and the stool bilirubin level test. Materials and Methods: The total bilirubin (TB) level contents in stool samples from 17 infants aged less than 1 year, seven with confirmed cholestatic jaundice and ten healthy subjects was measured, and outcome c...

  13. 2013 Annual National Digital Rectal Exam Day: impact on prostate health awareness and disease detection

    OpenAIRE

    Chua, Michael E.; Lapitan, Marie Carmela M.; Morales Jr, Marcelino L.; Roque, Aristotle Bernard Maniego; Domingo, John Kenneth

    2014-01-01

    Purpose: “Mag-paDRE” is a yearly prostate health public awareness program initiated by the Philippine Urological Association. This study aimed to describe the demographic and clinical data of the participants in the 2013 “Mag-paDRE” program and to identify factors that will further improve prostate health public awareness. Methods: A descriptive cross-sectional study undertaken to collect and assess the demographic data, International Prostate Symptom Score (IPSS) and digital rectal examinati...

  14. All-optical and digital non-linear compensation algorithms in flex-coherent grouped and un-grouped contiguous spectrum based networks

    DEFF Research Database (Denmark)

    Asif, Rameez

    2016-01-01

    We have evaluated that in-line non-linear compensation schemes decrease the complexity of digital backward propagation and enhance the transmission performance of 40/112/224 Gbit/s mixed line rate network. Multiple bit rates, i.e. 40/112/224 Gbit/s and modulation formats (i.e. DP-QPSK and DP-16QAM......) are transmitted over 1280 km of Large $$\\hbox {A}_{eff}$$ A e f f Pure-Silica core fiber. Both grouped and un-grouped spectral allocation schemes are investigated. Optical add-drop multiplexers are used to drop the required wavelength for signal processing in the transmission link. Moreover, hybrid mid...

  15. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simul