WorldWideScience

Sample records for diffractive multifocal intraocular

  1. Lente intra-ocular multifocal difrativa apodizada: resultados Diffractive apodized multifocal intraocular lens: results

    Directory of Open Access Journals (Sweden)

    Virgilio Centurion

    2007-12-01

    Full Text Available OBJETIVO: Mostrar os resultados visuais e refracionais com lente intra-ocular multifocal difrativa apodizada. MÉTODOS: Estudo de 100 olhos de 50 pacientes com catarata, submetidos à facoemulsificação com implante bilateral de lente intra-ocular (LIO multifocal difrativa apodizada. Foi avaliada a acuidade visual binocular sem e com correção para longe e perto, a previsibilidade refracional e a freqüência de uso de óculos. RESULTADOS: A acuidade visual sem correção para longe foi de e " 20/30 em 97,56% dos olhos operados e e" J2 em 100%, sendo que 82% dos pacientes nunca usam óculos e 16% usam de forma esporádica. CONCLUSÃO: A LIO multifocal difrativa apodizada mostrou ser uma opção previsível, reproduzível e segura na correção dos vícios de refração para longe e perto durante a cirurgia da catarata, permitindo elevado índice de independência ao uso de óculos.OBJECTIVE: To show visual and refraction results using multifocal diffractive apodized intraocular lens. METHODS: The study of 100 eyes of 50 patients with cataract, submitted to phacoemulsification with bilateral implant of multifocal diffractive apodized intraocular lens (IOL. Binocular visual acuity was evaluated with and without correction for near and distance, and refraction previsibility and frequency of wearing glasses. RESULTS: Visual acuity without correction for distance was e" 20/30 in 97.56% of eyes operated on and e" J2 in 100%, of these 82% of patients never wear glasses and 16% wear glasses sporadically. CONCLUSION: Multifocal diffractive apodized IOL proved to be a foreseeable option, reproducible and safe in the correction of refraction errors for distance and near during cataract surgery, enabling a high rate of independence from the use of glasses.

  2. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  3. Application of diffractive aspheric multifocal intraocular lens in the Uighur in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Nuersimanguli·Mijiti

    2016-05-01

    Full Text Available AIM:To research the efficacy and safety of diffractive aspheric multifocal intraocular lens(MIOLin the Uighur in phacoemulsification to provide guidance for the clinical treatment of cataracts patients in Xinjiang region. METHODS:Two hundred and twenty-eight Uygur patients(280 eyesreceived phacoemulsification from April 2012 to March 2013 were randomly divided into multifocal group(106 cases with 146 eyesand monofocal group(122 cases with 134 eyes. Patients were followed up for 3mo. The intraocular pressure(IOP, uncorrected distance visual acuity, uncorrected near vision, best-corrected distance visual acuity and best corrected near vision were measured. The delensed rate, visual quality, and satisfaction for lenses in the form of questionnaires were compared. RESULTS:Multifocal group was better on the uncorrected near vision than monofocal group(PP>0.05. The contrast sensitivity of multifocal group under scotopia at spatial frequency 3c/d was lower than that of monofocal group(PP>0.05. Delensed rate of multifocal group was higher than that of monofocal group(PP>0.05.CONCLUSION:MIOL with phacoemulsification can provide patient good full range vision, especially on good near vision. The patients with MIOL implanted have a higher delensed rate, less postoperative adverse symptoms, quicker recovery and satisfaction.

  4. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  5. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    Science.gov (United States)

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  6. Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.

    Science.gov (United States)

    Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro

    2012-03-01

    To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.

  7. Light distribution in diffractive multifocal optics and its optimization.

    Science.gov (United States)

    Portney, Valdemar

    2011-11-01

    To expand a geometrical model of diffraction efficiency and its interpretation to the multifocal optic and to introduce formulas for analysis of far and near light distribution and their application to multifocal intraocular lenses (IOLs) and to diffraction efficiency optimization. Medical device consulting firm, Newport Coast, California, USA. Experimental study. Application of a geometrical model to the kinoform (single focus diffractive optical element) was expanded to a multifocal optic to produce analytical definitions of light split between far and near images and light loss to other diffraction orders. The geometrical model gave a simple interpretation of light split in a diffractive multifocal IOL. An analytical definition of light split between far, near, and light loss was introduced as curve fitting formulas. Several examples of application to common multifocal diffractive IOLs were developed; for example, to light-split change with wavelength. The analytical definition of diffraction efficiency may assist in optimization of multifocal diffractive optics that minimize light loss. Formulas for analysis of light split between different foci of multifocal diffractive IOLs are useful in interpreting diffraction efficiency dependence on physical characteristics, such as blaze heights of the diffractive grooves and wavelength of light, as well as for optimizing multifocal diffractive optics. Disclosure is found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  9. Clinical outcomes of a new diffractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Baha Toygar

    2017-12-01

    Full Text Available AIM: To evaluate clinical outcomes after implantation of a new diffractive aspheric multifocal intraocular lens (IOL with +3.00 addition power. METHODS: This is a retrospective, consecutive case series of cataract patients who underwent bilateral implantation of the Optiflex MO/HF D012 (Moss Vision Inc. Ltd, London, UK multifocal IOL. Patients followed for 6mo were included in the study. Data on distance, intermediate and near visual acuity, refractive error [manifest spherical equivalent (MSE], contrast sensitivity, adverse events, subjective symptoms, spectacle independence and patient satisfaction [visual function questionnaire (VFQ-25 questionnaire] were retrieved from electronic medical records and analyzed. RESULTS: Forty eyes of 20 patients with a mean age of 66.7±8.5y (range: 53-82 were included in the study. Mean uncorrected distance, near and intermediate visual acuity remained stable through postoperative visits and was 0.19±0.19 logMAR, Jaeger 4 and Jaeger 3 respectively at the 6mo visit. At the end of postoperative 6mo, MSE was -0.14±0.42 diopters (D and 98% of the eyes were within 1.00 D of target refraction. Postoperative low contrast (10% visual acuity remained stable (P=0.54 through follow up visits with a mean of 0.35±0.17 logMAR at the 6mo visit. There were no reported adverse events. None of the patients reported subjective symptoms of halo or glare. Spectacle independence rate was 90%. Mean VFQ-25 questionnaire score was 93.5±6.12. CONCLUSION: The Optiflex MO/HF-DO12 IOL was safely implanted and successfully restored distance, intermediate and near visual acuity without impairing contrast sensitivity. High levels of spectacle independence were achieved at all distances including intermediate distance.

  10. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Ugur Unsal

    2016-01-01

    Full Text Available Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.. The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp. and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001. The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities, whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading.

  11. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    Science.gov (United States)

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  12. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes

    NARCIS (Netherlands)

    Nuijts, Rudy M. M. A.; Jonker, Soraya M. R.; Kaufer, Robert A.; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-01-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8

  13. Comparison of outcomes with multifocal intraocular lenses: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Béatrice Cochener

    2011-01-01

    Full Text Available Béatrice Cochener1, Antoine Lafuma2, Babak Khoshnood2, Laurène Courouve2, Gilles Berdeaux3,41Centre Hospitalier Universitaire Brest, Brest, France; 2Cemka Eval, Bourg la Reine, France; 3Alcon France, Rueil-Malmaison, France; 4Conservatoire National des Arts et Métiers, Paris, FrancePurpose: To compare the clinical outcome of different multifocal intraocular lenses (IOLs based on information reported in the international literature.Methods: All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected distance visual acuity, visual acuity, spectacle independence, and halos. Random effects meta-analyses were conducted to compare outcomes for the different IOL types.Results: Twenty papers were identified describing 11 monofocal IOLs and 35 multifocal IOLs (19 diffractive, including 12 ReSTOR®, 14 refractive, and two accommodative patient cohorts. Multifocal and monofocal uncorrected distance visual acuity was 0.165 (0.090–0.240 and 0.093 (0.088–0.098, respectively. Compared with monofocal IOLs, multifocal IOLs produced better uncorrected near visual acuity (0.470 [0.322–0.618] versus 0.141 [0.131–0.152]; P < 0.0001, resulting in higher spectacle independence (incidence rate ratio [IRR] 3.62 [2.90–4.52]; P < 0.0001. Compared with refractive multifocal IOLs, diffractive multifocal IOLs produced a similar uncorrected distance visual acuity (0.105 [0.098–0.111] versus 0.085 [0.029–0.140]; P ≤ 0.78, not significant and better uncorrected near visual acuity (0.217 [0.118–0.317] versus 0.082 [0.067–0.098]; P < 0.0001 resulting in higher spectacle independence (IRR 1.75 [1.24–2.48]; P < 0.001. Compared with other multifocal IOLs, ReSTOR produced a better uncorrected distance visual acuity (0.067 [0.059–0.076] versus 0.093 [0.088–0.098]; P < 0.0001 and better

  14. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses.

    Science.gov (United States)

    Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel

    2015-03-01

    To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312

  16. Comparison between OPD-Scan results and visual outcomes of monofocal and multifocal intraocular lenses Comparação dos resultados do OPD-Scan e performance visual das lentes intraoculares monofocal e multifocal

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2009-08-01

    Full Text Available PURPOSE: To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS: This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS: Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75% achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75% of the eyes achieved more than Jaeger 6. At least 87.5% of the multifocal group and 6.3% of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5 or better. And 90.0% of the eyes in the multifocal group and 37.5% in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6 or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379. The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014 and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units under mesopic conditions (p=0.044. CONCLUSION: The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.OBJETIVO: Comparar a performance visual, sensibilidade ao contraste e de wavefront com OPD-Scan em pacientes submetidos a cirurgia de facoemulsificação com implante de lente intraocular AcrySof SN60D3 multifocal e AcrySof SA60AT monofocal. MÉTODOS: Quarenta olhos com a lente intraocular multifocal e trinta e dois olhos com a lente intraocular

  17. Desempenho visual após implante de uma lente intraocular asférica multifocal difrativa Visual performance after implantation of an aspheric multifocal diffractive intraocular lens

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2010-08-01

    Full Text Available OBJETIVO: Avaliar a acuidade visual a distancia, intermediária e perto após o implante de uma lente intraocular (LIO asférica multifocal difrativa AcrySof® ReSTOR® SN6AD1. MÉTODOS: Estudo prospectivo de 50 pacientes com catarata submetidos à facoemulsificação e implante de LIO AcrySof® ReSTOR®. Foram avaliados acuidade visual sem correção (AVSC, acuidade visual com correção (AVCC para longe, acuidade visual para perto corrigida para longe (AVPC e acuidade visual intermediária corrigida para longe (AVIC. Um questionário de satisfação e fenômenos visuais foi administrado ao final do estudo. RESULTADO: Após três meses de cirurgia, a média das acuidades (logMAR era: AVSC, 0,05 ± 0,07; AVCC, 0,00 ± 0,01; AVPC, 0,00 ± 0,0, e AVIC, 0,15 ± 0,05. A AVCC e AVPC era de 20/25 ou melhor em todos os pacientes, sendo a AVIC J3 ou melhor em 83% dos pacientes. Pacientes relataram excelente desempenho visual nas questões relacionadas a atividades para distância, intermediário, e perto com pouca ou nenhuma dificuldade. Nenhum paciente relatou halos ou 'glare' severos, sendo os mesmos caracterizados entre nenhum a moderado. CONCLUSÃO: A LIO asférica AcrySof® ReSTOR® SN6AD1 mostrou excelentes resultados na visão para longe, perto e intermediário, além de apresentar uma baixa incidência de fenômenos visuais.PURPOSE: To evaluate distance, intermediate, and near vision after aspheric multifocal diffractive AcrySof® ReSTOR® SN6AD1 intraocular lens (IOL implantation. METHODS: Prospective study of 50 patients with cataract that had phacoemulsification and AcrySof® ReSTOR® IOL implantation. Uncorrected distance vision acuity (UDVA, corrected distance visual acuity (CDVA, distance-corrected near visual acuity (DCNVA, and distance-corrected intermediate visual acuity (DCIVA were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered at the end of the study. RESULTS: Three months

  18. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  19. Optimizing outcomes with multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gitansha Shreyas Sachdev

    2017-01-01

    Full Text Available Modern day cataract surgery is evolving from a visual restorative to a refractive procedure. The advent of multifocal intraocular lenses (MFIOLs allows greater spectacle independence and increased quality of life postoperatively. Since the inception in 1980s, MFIOLs have undergone various technical advancements including trifocal and extended depth of vision implants more recently. A thorough preoperative workup including the patients' visual needs and inherent ocular anatomy allows us to achieve superior outcomes. This review offers a comprehensive overview of the various types of MFIOLs and principles of optimizing outcomes through a comprehensive preoperative screening and management of postoperative complications.

  20. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Vrijman, V.; El-Saady, R.; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2014-01-01

    PURPOSE: To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). METHODS: This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric

  1. Near-point string: Simple method to demonstrate anticipated near point for multifocal and accommodating intraocular lenses.

    Science.gov (United States)

    George, Monica C; Lazer, Zane P; George, David S

    2016-05-01

    We present a technique that uses a near-point string to demonstrate the anticipated near point of multifocal and accommodating intraocular lenses (IOLs). Beads are placed on the string at distances corresponding to the near points for diffractive and accommodating IOLs. The string is held up to the patient's eye to demonstrate where each of the IOLs is likely to provide the best near vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  3. Refractive outcomes after multifocal intraocular lens exchange.

    Science.gov (United States)

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P exchange to 0.23 D after the exchange (P exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. [Influence of different multifocal intraocular lens concepts on retinal stray light parameters].

    Science.gov (United States)

    Ehmer, A; Rabsilber, T M; Mannsfeld, A; Sanchez, M J; Holzer, M P; Auffarth, G U

    2011-10-01

    Multifocal intraocular lenses (MIOL) are known to induce various photic phenomena depending on the optical principle. The aim of this study was to investigate the correlation between stray light measurements performed with the C-Quant (Oculus, Germany) and the results of a subjective patient questionnaire. In this study three different MIOLs were compared: AMO ReZoom (refractive design, n=10), AMO ZM900 (diffractive design, n=10) and Oculentis Mplus (near segment design, n=10). Cataract and refractive patients were enrolled in the study. Functional results were evaluated at least 3 months postoperatively followed by stray light measurements and a subjective questionnaire. Surgery was performed for all patients without complications. The three groups were matched for age, IOL power and corrected distance visual acuity (CDVA). Significantly different stray light (median) values log(s) were found (Kruskal-Wallis test, p<0.05): 1.12 log (refractive), 1.13 log (segment) and 1.28 log (diffractive). The subjective questionnaire did not show differences in glare perception but refractive MIOL patients noticed more halos surrounding light sources than the diffractive and segment MIOL patients. Stray light and subjective photopic phenomena do not show any basic correlation. Measurements in patients with refractive MIOLs showed less stray light than near segment or diffractive MIOLs. However, refractive MIOLs induced more halos compared to the other groups analyzed.

  5. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes.

    Science.gov (United States)

    Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-02-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  7. Bilateral implantation of +3.0 D multifocal toric intraocular lenses: results of a US Food and Drug Administration clinical trial.

    Science.gov (United States)

    Lehmann, Robert; Modi, Satish; Fisher, Bret; Michna, Magda; Snyder, Michael

    2017-01-01

    The purpose of this study was to evaluate the clinical outcomes of apodized diffractive +3.0 D multifocal toric intraocular lens (IOL) implantations in subjects with preoperative corneal astigmatism. This was a prospective cohort study conducted at 21 US sites. The study population consisted of 574 subjects, aged ≥21 years, with preoperative astigmatism 0.75-2.82 D, and potential postoperative visual acuity (VA) ≥0.2 logMAR, undergoing bilateral cataract removal by phacoemulsification. The intervention was bilateral implantation of aspheric apodized diffractive +3.0 D multifocal toric or spherical multifocal nontoric IOLs. The main outcome measures were monocular uncorrected near and distance VA and safety at 12 months. A total of 373/386 and 182/188 subjects implanted with multifocal toric and nontoric IOLs, respectively, completed 12-month follow-up after the second implantation. Toric IOLs were nonin-ferior in monocular uncorrected distance (4 m) and near (40 cm) VA but had >1 line better binocular uncorrected intermediate VA (50, 60, and 70 cm) than nontoric IOLs. Toric IOLs reduced cylinder to within 0.50 D and 1.0 D of target in 278 (74.5%) and 351 (94.1%) subjects, respectively. Mean ± standard deviation (SD) differences between intended and achieved axis orientation in the first and second implanted eyes were 5.0°±6.1° and 4.7°±4.0°, respectively. Mean ± SD 12-month IOL rotations in the first and second implanted eyes were 2.7°±5.8° and 2.2°±2.7°, respectively. No subject receiving toric IOLs required secondary surgical intervention due to optical lens properties. Multifocal toric IOLs were noninferior to multifocal nontoric IOLs in uncorrected distance and near VAs in subjects with preexisting corneal astigmatism and effectively corrected astigmatism of 0.75-2.82 D.

  8. Avaliação da sensibilidade ao contraste e da estereopsia em pacientes com lente intra-ocular multifocal Contrast sensitivity and stereopsis in pseudophakic patients with multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Filipe de Oliveira

    2005-08-01

    Full Text Available OBJETIVO: Avaliar a sensibilidade ao contraste e a acuidade estereoscópica em pacientes pseudofácicos, que receberam implante bilateral de lente intra-ocular multifocal. MÉTODOS: Prospectivamente foram realizados testes de sensibilidade ao contraste com o uso da tabela Pelli-Robson e teste de acuidade estereoscópica com emprego do Titmus Stereo Test, em 20 pacientes com implante bilateral de lente intra-ocular multifocal Acrysof Restor®, no pós-operatório de 1 a 2 meses e sem uso de qualquer correção óptica. RESULTADOS:O teste de sensibilidade ao contraste binocular demonstrou que 6 pacientes (30% apresentaram 1,80 unid. log, 13 (65% 1,65 e 1 (5% 1,50. No teste monocular, ocorreram as seguintes respostas: 17 pacientes (85% 1,65 unid. log e 3 (15% 1,50 para o teste do olho direito. O teste do olho esquerdo mostrou que 16 pacientes (80% apresentaram 1,65 unid. log e 4 (20% 1,50. A média e o desvio-padrão da sensibilidade ao contraste testada binocularmente foi 1,69 (±0,08, ao passo que monocularmente foi 1,63 (±0,05 para OD e 1,62 (±0,06 para OE. O teste de acuidade estereoscópica revelou que 12 pacientes (60% obtiveram 40", 6 (30% 50" e 2 (10% 60", com média de 45" e desvio-padrão de ±6,88". CONCLUSÃO: A lente intra-ocular empregada no estudo, proporcionou resultados de sensibilidade ao contraste e acuidade estereoscópica compatíveis e de acordo com critérios de normalidade estabelecidos anteriormente por outros estudos em grupos de pacientes fácicos e pseudofácicos, e portanto, impacto positivo na funcionalidade visual.PURPOSE: To evaluate the contrast sensitivity and stereopsis tests in patients who underwent bilateral implantation of multifocal intraocular lens. METHODS: Tests of contrast sensitivity using the Pelli-Robson chart and stereopsis evaluation with the Titmus Stereo Test were performed in 20 patients 30-60 days after the bilateral implantation of Acrysof Restor® multifocal intraocular lens. RESULTS: The

  9. Multifocal versus monofocal intraocular lenses after cataract extraction

    Directory of Open Access Journals (Sweden)

    Daniel Calladine

    Full Text Available BACKGROUND: Good unaided distance visual acuity is now a realistic expectation following cataract surgery and intraocular lens (IOL implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. OBJECTIVES: The objective of this review was to assess the effects of multifocal IOLs, including effects on visual acuity, subjective visual satisfaction, spectacle dependence, glare and contrast sensitivity, compared to standard monofocal lenses in people undergoing cataract surgery. METHODS: Search methods: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register, The Cochrane Library 2012, Issue 2, MEDLINE (January 1946 to March 2012, EMBASE (January 1980 to March 2012, the metaRegister of Controlled Trials (mRCT (www.controlled-trials.com, ClinicalTrials.gov (www.clinicaltrials.gov and the WHO International Clinical Trials Registry Platform (ICTRP (www.who.int/ictrp/search/en. We did not use any date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 6 March 2012. We searched the reference lists of relevant articles and contacted investigators of included studies and manufacturers of multifocal IOLs for information about additional published and unpublished studies. Selection criteria: All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. Data collection and analysis: Two authors collected data and assessed trial quality. Where possible, we pooled data from the individual studies using a random-effects model, otherwise we tabulated data. MAIN RESULTS: Sixteen completed trials

  10. Retreatments after multifocal intraocular lens implantation: an analysis

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-03-01

    Full Text Available Kjell Gunnar Gundersen,1 Sarah Makari,2 Steffen Ostenstad,1 Rick Potvin2 1Ifocus Eye Clinic, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL implantation and to evaluate the methods and clinical outcomes of retreatment.Patients and methods: A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients.Results: The multifocal retreatment rate was 10.8% (45/416 eyes. The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01. The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152 and bilateral trifocal (6.9%, 14/202 IOLs, was not statistically significantly different (P=0.12. In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time.Conclusion: Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. Keywords: piggyback IOL, Sulcoflex, toric, STAAR, symptoms, astigmatism

  11. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    Science.gov (United States)

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  12. Outcomes of excimer laser enhancements in pseudophakic patients with multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Schallhorn SC

    2016-04-01

    Full Text Available Steven C Schallhorn,1–3 Jan A Venter,2 David Teenan,2 Julie M Schallhorn,3 Keith A Hettinger,2 Stephen J Hannan,2 Martina Pelouskova2 1Department of Ophthalmology, University of California, San Francisco, CA, USA; 2Optical Express, Glasgow, UK; 3Department of Ophthalmology, University of Southern California, Los Angeles, CA, USA Purpose: The aim of this study was to assess visual and refractive outcomes of laser vision correction (LVC to correct residual refraction after multifocal intraocular lens (IOL implantation. Patients and methods: In this retrospective study, 782 eyes that underwent LVC to correct unintended ametropia after multifocal IOL implantation were evaluated. Of all multifocal lenses implanted during primary procedure, 98.7% were refractive and 1.3% had a diffractive design. All eyes were treated with VISX STAR S4 IR excimer laser using a convectional ablation profile. Refractive outcomes, visual acuities, patient satisfaction, and quality of life were evaluated at the last available visit. Results: The mean time between enhancement and last visit was 6.3±4.4 months. Manifest spherical equivalent changed from -0.02±0.83 D (-3.38 D to +2.25 D pre-enhancement to 0.00±0.34 D (-1.38 D to +1.25 D post-enhancement. At the last follow-up, the percentage of eyes within 0.50 D and 1.00 D of emmetropia was 90.4% and 99.5%, respectively. Of all eyes, 74.9% achieved monocular uncorrected distance visual acuity 20/20 or better. The mean corrected distance visual acuity remained the same before (-0.04±0.06 logMAR [logarithm of the minimum angle of resolution] and after LVC procedure (-0.04±0.07 logMAR; P=0.70. There was a slight improvement in visual phenomena (starburst, halo, glare, ghosting/double vision following the enhancement. No sight-threatening complications related to LVC occurred in this study. Conclusion: LVC in pseudophakic patients with multifocal IOL was safe, effective, and predictable in a large cohort of

  13. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  14. Reading ability with pseudophakic monovision and with refractive multifocal intraocular lenses: comparative study.

    Science.gov (United States)

    Ito, Misae; Shimizu, Kimiya

    2009-09-01

    To the compare the reading ability after bilateral cataract surgery in patients who had pseudophakic monovision achieved by monofocal intraocular lens (IOL) implantation and patients who had refractive multifocal IOL implantation. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. This study evaluated patients who had bilateral cataract surgery using the monovision method with monofocal IOL implantation to correct presbyopia (monovision group) or who had bilateral cataract surgery with refractive multifocal IOL implantation (multifocal group). In the monovision group, the dominant eye was corrected for distance vision and the nondominant eye for near vision. The maximum reading speed, critical character size, and reading acuity were measured binocularly without refractive correction using MNREAD-J acuity charts. The monovision group comprised 38 patients and the multifocal group, 22 patients. The mean maximum reading speed was 350.5 characters per minute (cpm) +/- 62.3 (SD) in the monovision group and 355.0 +/- 53.3 cpm in the multifocal group; the difference was not statistically significant. The mean critical character size was 0.24 +/- 0.12 logMAR and 0.40 +/- 0.16 logMAR, respectively (P<.05). The mean reading acuity was 0.05 +/- 0.12 logMAR and 0.19 +/- 0.11 logMAR, respectively (P<.01). The monovision group had better critical character size and reading acuity results. The monovision method group had better reading ability; however, careful patient selection is essential.

  15. In-the-bag decentration of a hydrophilic radially asymmetric multifocal intraocular lens secondary to capsule contraction.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    We report a case of in-the-bag decentration and tilt of a hydrophilic rotationally asymmetric multifocal intraocular lens (IOL) of the M Plus type secondary to capsule contraction. After uneventful surgery and follow-up for 3 months, progressive decentering and tilting of the IOL secondary to

  16. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  17. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  18. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    Science.gov (United States)

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  19. Calidad visual en pacientes con lente intraocular multifocal modelo OcuFlex operados de catarata The quality of vision in patients operated on from cataract and implanted with OcuFlex multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Eneida Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Describir la calidad visual en 8 pacientes operados de catarata bilateral con la técnica de Faco-chop e implante de lente intraocular multifocal modelo OcuFlex, en el ICO "Ramón Pando Ferrer", desde septiembre 2007 a febrero 2008. MÉTODOS: Se realizó un estudio observacional, descriptivo, longitudinal y prospectivo para lo cual se analizaron variables como equivalente esférico, sensibilidad al contraste en el preoperatorio y posoperatorio; fenómenos visuales, centrado y localización del lente intraocular, así como el estado de satisfacción subjetiva de los pacientes. Se utilizó la estadística descriptiva con ayuda del sistema Microsoft Excel y Word 2003, para Windows XP. RESULTADOS: El equivalente esférico medio posoperatorio fue -0,59 tanto para frecuencias bajas como medias, en visión binocular la sensibilidad al contraste media fue de 1,12 unid.log en el preoperatorio y de 1,74 unid.log. en el posoperatorio. Por biomicroscopia con lámpara de hendidura en el 100 % de los casos el lente intraocular estaba centrado y por biomicroscopia ultrasónica el 93,75 % se encontraba en el saco capsular. Ningún paciente refirió la presencia de glare y solamente uno (12,5 % reportó visión de halos nocturnos. La totalidad de los pacientes se manifestaron satisfechos. CONCLUSIONES: Los lentes multifocales disminuyen la dependencia de las gafas después de la cirugía de catarata, razón por la que constituye una buena opción en la recuperación de la función visual óptima.OBJECTIVE: To describe the quality of vision in 8 patients, who were operated on from bilateral cataract using Phaco-chop technique and implanted with Ocuflex multifocal intraocular lens in "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from September 2007 to February 2008. METHODS: A prospective, longitudinal, observational and descriptive study was made in which the variables spheral equivalent, contrast sensitivity in the pre- and post

  20. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.

    Science.gov (United States)

    Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J

    2012-02-01

    To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.

  1. Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy.

    Science.gov (United States)

    Kim, Kyeong Hwan; Seok, Kyung-Won; Kim, Wan Soo

    2017-11-01

    To report results of multifocal intraocular lens (IOL) implantation in 2 patients with refractive error and presbyopia after previous radial keratotomy (RK). A refractive multifocal IOL with rotational asymmetry (LS313-MF30; Oculentis, Berlin, Germany) was implanted. The first patient was a 60-year-old man with myopia who underwent unilateral RK 20 years before. His uncorrected distance visual acuity (UDVA) was 20/400, and his distance corrected near vision was J9 in both eyes. Six months after bilateral surgery, his binocular UDVA and uncorrected near visual acuity (UNVA) improved to 20/20 and J1, respectively, although he experienced diurnal fluctuation. The second patient was a 55-year-old woman with hyperopia who underwent bilateral RK 18 years before. Uncorrected distance visual acuity was 20/25 in both eyes, but UNVA was between J9 and J10. Three months after unilateral surgery, UDVA and UNVA of the postsurgical eye improved to 20/20 and J1, respectively. Neither patient reported any significant photic phenomena, and both were satisfied with the results of treatment. The desirable clinical outcomes and levels of satisfaction expressed by these patients indicate that surgery using this particular multifocal IOL may benefit presbyopic patients with previous RK.

  2. Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison

    Directory of Open Access Journals (Sweden)

    Ke Yao

    2013-06-01

    Full Text Available AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs.METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA and distance-corrected visual acuity (DCVA for distance, intermediate and near, spherical aberration (SA, contrast and glare sensitivity, near point refractive power, uncorrected and best-corrected near stereoscopic acuity (NSA. Patient satisfaction was assessed by a questionnaire.RESULTS: Three months postoperatively, the monocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups.CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo.

  3. Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon

    2016-04-01

    To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.

  4. [Halos and multifocal intraocular lenses: origin and interpretation].

    Science.gov (United States)

    Alba-Bueno, F; Vega, F; Millán, M S

    2014-10-01

    To present the theoretical and experimental characterization of the halo in multifocal intraocular lenses (MIOL). The origin of the halo in a MIOL is the overlaying of 2 or more images. Using geometrical optics, it can be demonstrated that the diameter of each halo depends on the addition of the lens (ΔP), the base power (P(d)), and the diameter of the IOL that contributes to the «non-focused» focus. In the image plane that corresponds to the distance focus, the halo diameter (δH(d)) is given by: δH(d)=d(pn) ΔP/P(d), where d(pn) is the diameter of the IOL that contributes to the near focus. Analogously, in the near image plane the halo diameter (δH(n)) is: δH(n)=d(pd) ΔP/P(d), where d(pd) is the diameter of the IOL that contributes to the distance focus. Patients perceive halos when they see bright objects over a relatively dark background. In vitro, the halo can be characterized by analyzing the intensity profile of the image of a pinhole that is focused by each of the foci of a MIOL. A comparison has been made between the halos induced by different MIOL of the same base power (20D) in an optical bench. As predicted by theory, the larger the addition of the MIOL, the larger the halo diameter. For large pupils and with MIOL with similar aspheric designs and addition (SN6AD3 vs ZMA00), the apodized MIOL has a smaller halo diameter than a non-apodized one in distance vision, while in near vision the size is very similar, but the relative intensity is higher in the apodized MIOL. When comparing lenses with the same diffractive design, but with different spherical-aspheric base design (SN60D3 vs SN6AD3), the halo in distance vision of the spherical MIOL is larger, while in near vision the spherical IOL induces a smaller halo, but with higher intensity due to the spherical aberration of the distance focus in the near image. In the case of a trifocal-diffractive IOL (AT LISA 839MP) the most noticeable characteristic is the double-halo formation due to the 2 non

  5. Visual performance after the implantation of a new trifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Vryghem JC

    2013-10-01

    Full Text Available Jérôme C Vryghem,1,2 Steven Heireman1,21Brussels Eye Doctors, Brussels, Belgium; 2Clinique Saint-Jean, Brussels, BelgiumPurpose: To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens.Methods: A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients.Results: The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09. LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced.Conclusion: The introduction of a third focus in diffractive multifocal

  6. Food and Drug Administration study update. One-year results from 671 patients with the 3M multifocal intraocular lens.

    Science.gov (United States)

    Lindstrom, R L

    1993-01-01

    The clinical evaluation of the Food and Drug Administration study of the 3M diffractive multifocal intraocular lens (IOL) is presented here to demonstrate the results of 1-year postoperative data accumulated for 671 patients, the first of whom received the implant in 1987. Patients were selected for study if they had absence of preoperative pathology, were at least 60 years of age, and had a reasonable postoperative prognosis. Extensive evaluations took place at 4 to 6 months and 12 to 14 months after surgery, including five different visual acuity measurements and contrast sensitivity. All testing was completed on both eyes. Data from the fellow eye served as a control when implanted with a monofocal IOL. Overall uncorrected distance visual acuity at 1 year after surgery shows 57% patients with 20/40 or better acuity. In this same group, 78% achieved J3 or better near vision, which improved to 82% in the best case group. Uncorrected visual acuity of 20/40 or better and J3 or better was achieved by 50% of best case multifocal IOL patients, compared with 26% of the monofocal best case comparison group. Measurements of contrast sensitivity consistently document a small loss, which is considered clinically insignificant. Statistical analysis of satisfaction ratings shows that predictors of satisfaction include uncorrected distance acuity, final near acuity, and fellow eye spherical equivalent. This multifocal lens appears to work very well for most patients, with more than half having functional uncorrected distance and near vision. The study showed several considerations that are important for optimizing clinical performance and patient satisfaction: patient selection, realistic expectations, accurate biometry, and adequate control of surgical procedures.

  7. Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

    Science.gov (United States)

    Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio

    2015-02-01

    To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.

  8. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens.

    Science.gov (United States)

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2014-12-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312 MF30, Oculentis, Germany). At 3 months postoperatively, the AR and MR values were compared to determine the correlation between the sphere (S), the spherical equivalent (SE) and the astigmatic components J0 and J45. The difference of mean spherical measurement was +0.98D ± 0.62, with the AR measuring more myopic. The difference of the mean spherical equivalent was +1.11D ± 0.57, again with AR being more myopic. Both these differences were statistically significant (p < 0.001). The astigmatic components showed less differences, with the mean difference of the J0 being -0.09D ± 0.43, and the J45 of +0.04D ± 0.47, which were both not statistically significant (p = 0.123 and p = 0.531, respectively). Correlation analysis of the refractive parameters showed r(2) = 0.067, r(2) = 0.078, r(2) = 0.018 and r(2) = 0.015, respectively, all of which point to a low correlation between the AR and the MR. Autorefraction shows poor correlation to manifest subjective refraction with these radially asymmetric multifocal IOLs. The autorefraction systematically underestimates the spherical and spherical equivalent power, while the correlation between the astigmatic components was also low. Autorefraction seems not a valid starting point for manifest subjective refraction with these types of lenses, unless a corrective factor of about +1 dioptre is used. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Clinical and patient-reported outcomes of bilateral implantation of a +2.5 diopter multifocal intraocular lens.

    Science.gov (United States)

    Maxwell, Andrew; Holland, Edward; Cibik, Lisa; Fakadej, Anna; Foster, Gary; Grosinger, Les; Moyes, Andrew; Nielsen, Stephen; Silverstein, Steven; Toyos, Melissa; Weinstein, Arthur; Hartzell, Scott

    2017-01-01

    To assess the effectiveness and safety of a multifocal intraocular lens (IOL) with +2.5 diopter (D) additional power compared with a monofocal IOL. Fifteen sites in the United States. Prospective randomized patient- and observer-masked clinical trial. Randomized patients received multifocal or monofocal IOLs bilaterally. Visual acuity (33 cm, 40 cm, 53 cm, 60 cm, 4 m) was measured; safety was assessed through adverse event rates. Patient-reported visual outcomes were evaluated using the Visual Tasks questionnaire. The frequency and severity of visual disturbances were evaluated using the Assessment of Photic Phenomena and Lens EffectS questionnaire. The multifocal IOL (n = 155) provided better corrected distance visual acuity at 53 cm than the monofocal IOL (n = 165) (0.322 versus 0.512 logMAR; between-group difference, -0.190 logMAR; P < .0001) and 40 cm but not at 4 m. Ocular adverse event rates were less than 3.84% in both groups. Serious adverse event rates were comparable between the 2 IOL types. Patients with multifocal IOLs reported less difficulty with near tasks (with and without correction) and intermediate tasks (without correction). Difficulty with extended-intermediate and distance tasks was similar between groups. The most frequently reported self-rated severe phenomena were halos, starbursts, and glare. Most patients (monofocal ≥72%; multifocal ≥73%) reported never experiencing blurred, distorted, or double vision. The +2.5 D multifocal IOL provided better vision at 40 cm and 53 cm and similar vision at 4 m compared with the monofocal IOL. Safety profiles and visual phenomena were comparable between groups. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Spectacle Independence after Cataract Extraction in Post-Radial Keratotomy Patients Using Hybrid Monovision with ReSTOR® Multifocal and TECNIS® Monofocal Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Isha Gupta

    2014-05-01

    Full Text Available Background: We report 2 patients who have undergone radial keratotomy (RK preceding ReSTOR® multifocal intraocular lens (IOL; Alcon, Fort Worth, Tex., USA implantation in their nondominant eyes and TECNIS® monofocal IOL (Abbott Medical Optics, Abbott Park, Ill., USA in their dominant eyes. Methods: Retrospective review of 2 patients who underwent hybrid monovision with ReSTOR® multifocal and TECHNIS® monofocal IOLs at the time of cataract surgery after a remote history of RK. Results: Implantation of the ReSTOR® multifocal and the TECHNIS® monofocal IOLs was successful, with no reported adverse events. The patients were able to achieve spectacle freedom. Conclusion: We report a novel technique for the management of post-RK patients to optimize their chances for spectacle independence.

  11. Correction of High Astigmatism after Penetrating Keratoplasty with Toric Multifocal Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-07-01

    Full Text Available After penetrating keratoplasty (PK, high astigmatism is often induced, being frequently about 4–6 dpt. According to the entity and typology of astigmatism, different methods of correction can be used. Selective suture removal, relaxing incisions, wedge resections, compression sutures, photorefractive keratectomy, and laser-assisted in situ keratomileusis can reduce corneal astigmatism and ametropia, but meanwhile they can cause a reduction in the corneal integrity and cause an over- or undercorrection. In case of moderate-to-high regular astigmatisms, the authors propose a toric multifocal intraocular lens (IOL implantation to preserve the corneal integrity (especially in PK after herpetic corneal leukoma keratitis. We evaluated a 45-year-old patient who at the age of 30 was subjected to PK in his left eye due to corneal leukoma herpetic keratitis, which led to high astigmatism (7.50 dpt cyl. 5°. The patient was subjected to phacoemulsification and customized toric multifocal IOL implantation in his left eye. The correction of PK-induced residual astigmatism with a toric IOL implantation is an excellent choice but has to be evaluated in relation to patient age, corneal integrity, longevity graft, and surgical risk. It seems to be a well-tolerated therapeutic choice and with good results.

  12. Comparison of visual function and patient satisfaction with AcrySof ReSTORSN6AD1 multifocal intraocular compared to monofocal intraocular lenses 5

    Directory of Open Access Journals (Sweden)

    Aisa S Alchinova

    2016-12-01

    Full Text Available Aim. To compare visual function and satisfaction in patients after implantation of AcrySof ReSTOR SN6AD1 multifocal intraocular lens (IOL, AcrySof SA60AТ spherical monofocal IOL, or Akreos АО aspheric monofocal IOL during cataract surgery. Materials. Overall, 34 patients received SN6AD1 multifocal (group 1, 48 eyes, 19 patients received Akreos АО monofocal aspheric (group 2, 30 eyes, and 13 patients received AcrySof SA60AТ monofocal spherical (group 3, 18 eyes IOL. Patients with multifocal IOL were closely matched for age, sex, and ocular findings with patients who had monofocal IOL implantation. Six months postoperatively, uncorrected/corrected distance visual acuity (UDVA/CDVA, uncorrected intermediate (60 cm and near (35 cm visual acuity (UNVA, defocus curve, contrast sensitivity, and a quality-of-life questionnaire were evaluated. Furthermore, independence from glasses and presence of optical phenomena were assessed. Results. Patients in group 2 had statistically significant increase in UDVA than that in group 1 (p = 0.037. There was no significant difference in the mean uncorrected intermediate and best corrected distance visual acuities between the groups. UNVA was better in group 1 than that in groups 2 and 3 (p < 0.0001. Photopic contrast sensitivity for high spatial frequencies was better in groups 2 and 3. Glare was reported in 5.9% of patients in group 1. Halos occurred in 32.4% of patients in group 1. No one reported undesirable visual symptoms in groups 2 and 3. Conclusion. Multifocal IOLs provided higher spectacle independence and satisfactory functional vision over a broad range of distances but were associated with increased subjective visual symptoms and reduced photopic contrast sensitivity for high spatial frequencies and distance visual quality compared with monofocal IOLs.

  13. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo

    2013-04-01

    To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.

  14. Acuidade visual em implantes bilaterais de lentes intra-oculares monofocais e multifocais Visual acuity of bilateral implants of monofocal and multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2003-01-01

    Full Text Available OBJETIVO: Comparar a acuidade visual de longe e perto de pacientes submetidos à facoemulsificação binocular não simultânea com implante de lentes multifocais ou monofocais. MÉTODOS: Foram selecionados 20 pacientes com lentes multifocais bilaterais e outros 20 pacientes com lentes monofocais também bilaterais, com acuidade visual sem correção melhor ou igual a 0,63 (20/30, medidos separadamente, nos três primeiros meses de pós-operatório. Foi medida a acuidade visual para longe e perto com e sem correção e testes de sensibilidade ao contraste e ofuscamento. RESULTADOS: A acuidade visual sem correção para longe no grupo das monofocais teve média de 0,82 (DP± 0,16 e no grupo das multifocais, 0,94 (DP±0,12, valor de p 0,001. Os dois grupos de lentes tiveram visão com correção para longe igual a 1. No grupo das multifocais, 75% tiveram J1 e 100% tiveram J3 ou melhor sem correção. No grupo das lentes monofocais, 10% tiveram J1 e 70% tiveram J3 ou melhor sem correção. Não houve diferença significante na avaliação com o teste de sensibilidade ao contraste entre os grupos pesquisados. No teste de ofuscamento, os dois grupos tiveram redução da visão, que foi mais acentuada no grupo dos pacientes com lentes multifocais. CONCLUSÃO: A acuidade visual para longe com correção nos pacientes com implante multifocal foi semelhante a dos pacientes com implantes monofocais, embora a acuidade visual para perto no grupo em que foi implantado lente multifocal foi bastante superior ao grupo da lente monofocal. A sensibilidade ao contraste manteve-se semelhante nos dois grupos, já o ofuscamento ("glare test" no grupo multifocal foi maior que no grupo monofocal.PURPOSE: To compare distant and near visual acuity between patients submitted to bilateral nonsimultaneous facoemulsification and implantation of multifocal or monofocal intraocular lenses (IOL. METHODS: Twenty patients with bilateral multifocal IOL and 20 patients with

  15. X-ray diffraction enhanced imaging study of intraocular tumors in human beings

    International Nuclear Information System (INIS)

    Tan Gao; Wang Huaqiao; Chen Yu; Yuan Qing; Li Gang; Zhu Peiping; Zhang Xiaodan; Zhong Xiufeng; Tang Jintian

    2010-01-01

    Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroid and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method. (authors)

  16. [Multifocal phakic intraocular lens implant to correct presbyopia].

    Science.gov (United States)

    Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C

    2005-03-01

    Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.

  17. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications.

    Science.gov (United States)

    Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen

    2016-02-01

    We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Small-Gauge Pars Plana Vitrectomy for the Management of Symptomatic Posterior Vitreous Detachment after Phacoemulsification and Multifocal Intraocular Lens Implantation: A Pilot Study from the Pan-American Collaborative Retina Study Group

    Science.gov (United States)

    Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio

    2015-01-01

    Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590

  19. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    Science.gov (United States)

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P 0; P .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  20. Subjective evaluation of uncorrected vision in patients undergoing cataract surgery with (diffractive multifocal lenses and monovision

    Directory of Open Access Journals (Sweden)

    Stock RA

    2017-07-01

    Full Text Available Ricardo Alexandre Stock, Thaís Thumé, Luan Gabriel Paese, Elcio Luiz Bonamigo Universidade do Oeste de Santa Catarina, Rua Getúlio Vargas, Joaçaba, Santa Catarina, Brazil Purpose: To analyze patient satisfaction and difficulties with bilateral multifocal intraocular lenses (IOLs implantation and aspheric monofocal IOLs implantation using monovision, after cataract surgery.Materials and methods: A total of 61 participants were included in the study, 29 with monovision and 32 with multifocal lenses. The inclusion criteria were patients undergoing phacoemulsification for bilateral visual impairment due to cataracts and presenting with postoperative visual acuity of 20/30 or better for distance and line J3 or better for near vision.Results: The 2 groups had similar results regarding difficulties with daily activities such as distance vision, near vision, watching television, reading, cooking, using a computer or cellphone, shaving/putting on makeup and shopping. There were differences in responses between the groups regarding difficulty with night vision (P=0.0565 and night driving (P=0.0291. Degree of satisfaction in terms of distance vision without glasses was statistically significantly better in monovision group (P=0.0332, but not for near (P=0.9101.Conclusion: Both techniques yielded satisfactory results regarding visual acuity for different activities without the need to use glasses. Multifocal lenses are a good option for patients with the exception of night driving, and who desire independence from glasses. Keywords: cataract extraction, aphakia, postcataract, patient satisfaction, night vision

  1. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-08-01

    Full Text Available Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions – with the consequent need for cross-linking – intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  2. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  3. Clinical Evaluation of Reading Performance Using the Salzburg Reading Desk With a Refractive Rotational Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe

    2016-08-01

    To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.

  4. Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free?

    Science.gov (United States)

    Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil

    2016-04-01

    To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  6. Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision.

    Science.gov (United States)

    Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio

    2017-06-01

    To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  8. Multifocal choroiditis following simultaneous hepatitis A, typhoid, and yellow fever vaccination

    Directory of Open Access Journals (Sweden)

    Escott S

    2013-02-01

    Full Text Available Sarah Escott, Ahmad B Tarabishy, Frederick H DavidorfHavener Eye Institute, The Ohio State University, Columbus, OH, USAAbstract: The paper describes the first reported case of multifocal choroiditis following simultaneous hepatitis-A, typhoid, and yellow fever vaccinations. A 33-year-old male developed sudden onset of flashing lights and floaters in his right eye 3 weeks following hepatitis A, typhoid, and yellow fever vaccinations. Fundus examination and angiography confirmed the presence of multiple peripheral chorioretinal lesions. These lesions demonstrated characteristic morphologic changes over a period of 8 weeks which were consistent with a diagnosis of self-resolving multifocal choroiditis. Vaccine-induced intraocular inflammation has been described infrequently. We demonstrate the first case of self-resolving multifocal choroiditis following simultaneous administration of hepatitis A, yellow fever, and typhoid immunizations.Keywords: multifocal choroiditis, vaccination, hepatitis A, typhoid, yellow fever

  9. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  10. Comparison between OPD-scan results and contrast sensitivity of three intraocular lenses: spheric AcrySof SN60AT, aspheric AcrySof SN60WF and multifocal AcrySof Restor lens Estudo comparativo da análise de frente de onda e sensibilidade ao contraste entre as lentes intra-oculares multifocal AcrySof Restor SN60D3, monofocal AcrySof SN60WF asférica e a monofocal SN60AT esférica

    Directory of Open Access Journals (Sweden)

    Celso Takashi Nakano

    2009-08-01

    ção com implantes de lentes intraoculares AcrySof SN60D3 multifocal, AcrySof SN60WF monofocal asférica e AcrySof SA60AT monofocal esférica. Métodos: Trinta e dois olhos com a lente intraocular multifocal, 32 olhos com a lente intraocular monofocal asférica e 32 olhos com a lente intraocular monofocal esférica. A avaliação oftalmológica foi realizada no primeiro, terceiro, sétimo, e nonagésimo dia pós-operatório. Todos os exames foram padronizados, realizada por um único examinador sob condições controladas de luminosidade fotópicas estabelecidas em 85 cd/m², medida por meio de tabelas de ETDRS, sensibilidade ao contraste e análise de aberrometria com OPD-Scan. Resultados: As médias de aberração total foi superior no grupo SN60AT (KW = 9.42; p=0.009 quando comparada com o grupo SN60D3 (p=0.016 e o grupo SN60WF (p=0.0047. O grupo SN60AT (KW = 16.20; p=0.0003 apresentou superioridade nas medias de aberração esférica comparada com o grupo SN60WF (p=0.00046 e o grupo SN60D3 (p=0.0014. Nenhuma diferença significante foi encontrada na acuidade visual para longe com e sem correção óptica com a tabela de ETDRS a 100% e 9% de contraste. O grupo SN60D3 comparada a SN60AT (p=0.016 apresentou baixa sensibilidade ao contraste em condições fotópicas com diferença estatística a 6.0 cpg (KW = 7.84; p=0.0199, mas sem diferença estatística entre os grupos SN60WF e SN60AT (p=0.91 e entre os grupos SN60WF e SN60D3 (p=0.051. O grupo SN60D3 apresentou baixa sensibilidade ao contraste em condições mesópicas (KW = 10.79; p=0,0045 a 6cpg quando comparada com o grupos SN60AT (p=0.011 e SN60WF (p=0.007. Conclusão: As lentes intraoculares multifocais e asféricas apresentaram menos aberração esférica quando comparadas à lente intraocular esférica, além da prevista multifocalidade sem correção para longe e perto. Entretanto, o grupo multifocal apresentou baixa sensibilidade ao contraste.

  11. Comparative study on optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis ® ZMB00 and AcrySof ® IQ ReSTOR ® Multifocal IOL SN6AD1

    Directory of Open Access Journals (Sweden)

    Mario Augusto Pereira Dias Chaves

    2016-06-01

    Full Text Available ABSTRACT Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D, and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA, corrected distance visual acuity (CDVA, distance-corrected near visual acuity (DCNVA, and distance-corrected intermediate visual acuity (DCIVA, with analysis of contrast sensitivity (CS, wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868; postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68; DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000; and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001. In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05. Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04; however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003. The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for

  12. DESIGN OF THE MULTIORDER INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    V. G. Kolobrodov

    2015-01-01

    Full Text Available Intraocular lenses (IOLs are used to replace the natural crystalline lens of the eye. Just few basic designs of IOLs are used clinically. Multiorder diffractive lenses (MODL which operate simultaneously in several diffractive orders were proposed to decrease the chromatic aberration. Properties analysis of MODL showed a possibility to use them to develop new designs of IOLs. The purpose of this paper was to develop a new method of designing of multiorder intraocular lenses with decreased chromatic aberration. The theoretical research of the lens properties was carried out. The diffraction efficiency dependence with the change of wavelength was studied. A computer simulation of MODL in a schematic model of the human eye was carried out. It is found the capability of the multiorder diffractive lenses to focus polychromatic light into a segment on the optical axis with high diffraction efficiency. At each point of the segment is present each component of the spectral range, which will build a color image in combination. The paper describes the new design method of intraocular lenses with reduced chromaticism and with endless adaptation. An optical system of an eye with an intraocular lens that provides sharp vision of objects located at a distance of 700 mm to infinity is modeled.

  13. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    Science.gov (United States)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  14. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  15. Implantation of a multifocal toric intraocular lens with a surface-embedded near segment after repeated LASIK treatments.

    Science.gov (United States)

    Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P

    2012-11-01

    We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    Science.gov (United States)

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  17. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2015-06-01

    Full Text Available AIM:To evaluate the prediction error in intraocular lens (IOL power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP.METHODS:Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany. In all cases, an adjusted IOL power (PIOLadj was calculated based on Gaussian optics using a variable keratometric index value (nkadj for the estimation of the corneal power (Pkadj and on a new value for ELP (ELPadj obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay Ⅰ.RESULTS:PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05. In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D and limits of agreement (of 1.47 and -1.61 D when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01 and was found to be dependent on axial length, anterior chamber depth and Pkadj.CONCLUSION:Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  18. A Rapid and Convenient Procedure to Evaluate Optical Performance of Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Frank Schaeffel

    2014-09-01

    Full Text Available A new portable lens scanner was developed and tested for measuring focal lengths and relative contrast transfer of mono- and multifocal intraocular lenses (IOLs. A photograph of a natural scene was imaged in white light through an IOL in a water-filled cuvette, with their +21D base power largely neutralized by a −20D trial lens, using a USB monochrome video camera that could be focused via a laptop-controlled stepping motor from −8.5 to + 8.0D. The output of 10000 ON-OFF antagonistic “receptive fields” measuring the video image with adjustable diameter was continuously recorded by custom written software to quantify focus and relative contrast. Six monofocal and four multifocal IOLs, as well as two radial refractive gradient (RRG lenses were measured. After calibration with trial lenses the optical powers and relative contrast transfer of mono- and multifocal IOLs were readily measured. Refractive power profiles measured in RRG lenses closely matched data obtained from the manufacturer. The lens scanner uses a rapidly operating procedure, is portable and can be used to verify positions of the focal planes of mono- and multifocal IOLs in less than 3 s.

  19. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    Science.gov (United States)

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  20. [Incremental cost effectiveness of multifocal cataract surgery].

    Science.gov (United States)

    Pagel, N; Dick, H B; Krummenauer, F

    2007-02-01

    Supplementation of cataract patients with multifocal intraocular lenses involves an additional financial investment when compared to the corresponding monofocal supplementation, which usually is not funded by German health care insurers. In the context of recent resource allocation discussions, however, the cost effectiveness of multifocal cataract surgery could become an important rationale. Therefore an evidence-based estimation of its cost effectiveness was carried out. Three independent meta-analyses were implemented to estimate the gain in uncorrected near visual acuity and best corrected visual acuity (vision lines) as well as the predictability (fraction of patients without need for reading aids) of multifocal supplementation. Study reports published between 1995 and 2004 (English or German language) were screened for appropriate key words. Meta effects in visual gain and predictability were estimated by means and standard deviations of the reported effect measures. Cost data were estimated by German DRG rates and individual lens costs; the cost effectiveness of multifocal cataract surgery was then computed in terms of its marginal cost effectiveness ratio (MCER) for each clinical benefit endpoint; the incremental costs of multifocal versus monofocal cataract surgery were further estimated by means of their respective incremental cost effectiveness ratio (ICER). An independent meta-analysis estimated the complication profiles to be expected after monofocal and multifocal cataract surgery in order to evaluate expectable complication-associated additional costs of both procedures; the marginal and incremental cost effectiveness estimates were adjusted accordingly. A sensitivity analysis comprised cost variations of +/- 10 % and utility variations alongside the meta effect estimate's 95 % confidence intervals. Total direct costs from the health care insurer's perspective were estimated 3363 euro, associated with a visual meta benefit in best corrected visual

  1. Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Kretz, Florian Tobias Alwin; Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe

    2016-10-01

    To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.

  2. A contralateral eye study comparing apodized diffrative and full diffrative lenses: wavefront analysis and distance and near uncorrected visual acuity

    Directory of Open Access Journals (Sweden)

    Marcony Rodrigues de Santhiago

    2009-01-01

    Full Text Available PURPOSE: To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses. METHODS: This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multifocal intraocular lens in the other eye. The main outcome measures, over a 3-month follow-up period, were the uncorrected photopic distance and near visual acuity and the defocus curve. The visual acuity was converted to logMAR for statistical analysis and is presented in decimal scale. The wavefront error and modulation transfer function were also evaluated in both groups. RESULTS: At the 3-month postoperative visit, the mean photopic distance uncorrected visual acuity (UCVA was 0.74 ± 0.20 in the ReSTOR group and 0.76 ± 0.22 in the Tecnis group (p=0.286. The mean near UCVA was 0.96 ± 0.10 in the ReSTOR group and 0.93 ± 0.14 in the Tecnis group (p=0.963. The binocular defocus curve showed measurements between the peaks better than 0.2 logMAR. The total aberration, higher-order aberration and coma aberration were not significantly different between the groups. The spherical aberration was significantly lower in the Tecnis group than in the ReSTOR group. (p=0.004. Both groups performed similarly for the modulation transfer function. CONCLUSION: The ReSTOR SN60D3 and Tecnis ZM 900 intraocular lenses provided similar photopic visual acuity at distance and near. The diffractive intraocular lenses studied provided a low value of coma and spherical aberrations, with the Tecnis intraocular lens having a statistically lower spherical aberration compared to the ReSTOR intraocular lens. In the 5 mm pupil diameter analyses, both intraocular lens groups showed similar modulation transfer functions.

  3. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2016-05-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To compare the visual acuity (VA and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye.Patients and methods: Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated.Results: Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05 at vergences from -0.5 to -1.5 D (from 2 m to 67 cm viewing distance, P<0.05. There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05.Conclusion: Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at

  4. INTRAOCULAR CORRECTION OF PRESBYOPIA BY MONOVISION IN PATIENTS WITH CATARACT AND CORNEAL ASTIGMATISM

    Directory of Open Access Journals (Sweden)

    E. I. Belikova

    2017-01-01

    Full Text Available Purpose: To evaluate the results of intraocular correction of presbyopia by monovision in patients with cataract and primary corneal astigmatism and conduct a comparative analysis of these outcomes with the results of binocular multifocal IOLs implantation. Patients and methods. There were 21 patients with bilateral cataract surgery performed using toric monofocal intraocular lenses (monovision group in the study. The indications for the operation were: 1 primary corneal astigmatism ≥ 1.0D in patients with cataract, 2 inability to conduct excimer laser correction. Reduction of spectacle dependence by monovision was discussed during preoperative conversation. The age of patients range from 32 to 65 years. Target refraction: Emetronopia on the dominant eye (DG and myopia at 1.0–2.0 D in the non-dominant eye (NDG. Evaluation included measurement of uncorrected visual acuity, refraction, stereopsis, contrast sensitivity and patient satisfaction. The results were compared with the outcomes of binocular multifocal Iols implantation in 22 patients (44 eyes. Results. The spherical component decreased from 3.39±2.63D to 0.34±0.24D, cylinder decreased from 3.05±1.47D to 0.44±0,35D (P <0.01 in the monovision group three months after surgery . The deviation from target refraction was 0.30±0.35D. The mean difference between postoperative refraction on the two eyes was 1.92±0.57D. Postoperative corrected visual acuity significantly exceeded preoperative parameters. In 18 patients (88% the stereoscopic visual acuity did not exceed 60 seconds and corresponded to the age norm, in 3 patients (12% it was at the level of 80–100 arc seconds. In patients with multifocal IOLs, the stereovision values were identical (Ferrer-Blasco T. et al, 2008. Conclusion. The monovision is an effective method of reducing dependence on additional correction in patients with cataract and corneal astigmatism. Refractive outcomes, binocular visual acuity, predictability and

  5. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  6. Diffractive optics for industrial and commercial applications

    Energy Technology Data Exchange (ETDEWEB)

    Turunen, J. [Joensuu Univ. (Finland); Wyrowski, F. [eds.] [Jena Univ. (Germany)

    1997-12-31

    The following topics were dealt with: diffractive optics, diffraction gratings, optical system design with diffractive optics, continuous-relief diffractive lenses and microlens arrays, diffractive bifocal intraocular lenses, diffractive laser resonators, diffractive optics for semiconductor lasers, diffractive elements for optical image processing, photorefractive crystals in optical measurement systems, subwavelenth-structured elements, security applications, diffractive optics for solar cells, holographic microlithography. 999 refs.

  7. Optical implementation of multifocal programmable lens with single and multiple axes

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Lenny A; Millan, Maria S; Perez-Cabre, Elisabet, E-mail: lenny.alexandra.romero@upc.edu [Optics and Optometry Dep. Technical University of Catalonia Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    In this work we analyse the generation of a diffractive optical element (DOE) consisting of a multifocal Fresnel lens by means of an LCoS (liquid cristal on silicon) spatial light modulator (SLM). The multifocal lens is composed of a set of lenses of different focal length that share a common optical axis (coaxial combination) or have different axes in parallel (multi-axis combination). For both configurations, we present several ways to combine the phase distributions for three lenses with different focal lengths (f1, f2, f3), into a single-phase distribution addressed to the SLM. Numerical simulations were carried out along with the experimental analysis to corroborate the results.

  8. Spectacle independence and subjective satisfaction of ReSTOR® multifocal intraocular lens after cataract or presbyopia surgery in two European countries

    Directory of Open Access Journals (Sweden)

    Béatrice Cochener

    2010-02-01

    Full Text Available Béatrice Cochener1, Luis Fernández-Vega2, Jose F Alfonso2, Frédérique Maurel3, Juliette Meunier4, Gilles Berdeaux5,61Centre Hospitalier de Brest, Brest, France; 2Instituto Oftalmologico Fernandez Vega, Oviedo, Spain; 3IMS Health, Health Economics Department, Puteaux, France; 4Mapi Values, Lyon, France; 5Alcon France, Health Economics Department, Rueil-Malmaison, France; 6Conservatoire National des Arts et Métiers, Paris, FrancePurpose: To determine the percentage of patients implanted bilaterally with ReSTOR® requiring spectacles at 18 months, the patient satisfaction, and factors that predict spectacles independence.Methods: The medical and surgical data were collected from patient records. The ‘Freedom from Spectacles Value Scale’ (FGVS was used to rank their experiences via telephone interview. A Bayesian network was used to predict postoperative spectacles use.Results: 304 patients (65.6 years were included. Postoperative visual acuity was ≥0.8 in 93.3% of patients for near vision and in 88.6% of patients for distance vision. After surgery, 87.2% of the patients were spectacles free. 88.2% of the patients rated their vision as being better following the surgery and 93.1% thought that surgery resulted in a positive change. FGVS mean scores (5 the most favorable rating were: ‘Practical Advantages’ 3.8, ‘Psychological Advantages’ 3.8, ‘Evaluation of the Result’ 4.5, ‘Feelings’ 4.4, and ‘Global Judgement’ 4.4. Patients who stated that spectacles wear was particularly bothersome and those who thought that their appearance was more favorable without spectacles were 3 times more likely not to wear spectacles postoperatively.Conclusion: ReSTOR® provides patients with good distance and near vision, a high rate of spectacles independence, and a high degree of patient satisfaction.Keywords: cataract surgery, multifocal intraocular lens, patient satisfaction, spectacles independence

  9. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Wei Ching-Kuo

    2012-10-01

    Full Text Available Abstract Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  10. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses.

    Science.gov (United States)

    Wei, Ching-Kuo; Wang, Shun-Mu; Lin, Jen-Chieh

    2012-10-29

    The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients' decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one's own expense, overall patient satisfaction and postoperative visual clarity. The results showed that the patient's gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  11. [In Vitro Evaluation of the Optical Quality of Segmental Refractive Multifocal Intraocular Lenses].

    Science.gov (United States)

    Yildirim, Timur Mert; Auffarth, Gerd Uwe; Tandogan, Tamer; Liebing, Stephanie; Labuz, Grzegorz; Choi, Chul Young; Khoramnia, Ramin

    2017-11-08

    In customised patient care, it is important to know the optical quality of different intraocular lenses (IOL). In this study, the optical quality of three segmental intraocular lenses were compared. The LENTIS Comfort LS-313 MF15, LENTIS Mplus X LS-313 MF30 and LENTIS High Add IOL LS-313 MF80 (Oculentis, Berlin, Germany) with a far power of + 21 D were analysed at the optical bench OptiSpheric IOL PRO (Trioptics GmbH, Wedel, Germany). The lenses have almost the same optical design but differ in the power of the near segment. The MF15 has a + 1.5 D addition to improve vision in intermediate distances, the MF30 has a near addition of + 3 D and the MF80 has a near addition of + 8 D. The modulation transfer function area (MTFa) and the Strehl ratio were examined for apertures of 3 mm (photopic) and 4.5 mm (mesopic). The MTFa values for the far focus are 33.34/30.80/51.53 (MF15/MF30/MF80) with an aperture of 3 mm and 25.38/22.52/43.15 for 4.5 mm. The MTFa values for the intermediate focus are 29.85/16.21/6.25 for a 3 mm aperture and 23.92/8.05/3.08 for 4.5 mm. The MTFa values for the near focus are 9.75/21.49/33.12 for an aperture of 3 mm and 4.95/22.70/31.68 for 4.5 mm. The Strehl ratio of the far focus is 0.34/0.30/0.52 for an aperture of 3 mm and 0.24/0.22/0.43 for 4.5 mm. For the intermediate focus, the Strehl ratio is 0.30/0.17/0.07 for an aperture of 3 mm and 0.24/0.08/0.03 for 4.5 mm. The Strehl ratio of the near focus is 0.10/0.22/0.33 for an aperture of 3 mm and 0.05/0.23/0.32 for 4.5 mm. We confirmed that the addition influences the optical quality of segmental bifocal intraocular lenses. For the far focus, the results of the MF15 and MF30 are similar. In intermediate distances, the MF15 achieves the best results. For near distances, the MF30 achieves better optical values than the MF15. The lens MF80, which has been designed for patients with maculopathies, achieves good results for far and near distances. Georg

  12. Multifocal Congenital Hemangiopericytoma.

    Science.gov (United States)

    Robl, Renata; Carvalho, Vânia Oliveira; Abagge, Kerstin Taniguchi; Uber, Marjorie; Lichtvan, Leniza Costa Lima; Werner, Betina; Mehrdad Nadji, Mehrdad

    2017-01-01

    Congenital hemangiopericytoma (HPC) is a rare mesenchymal tumor with less aggressive behavior and a more favorable prognosis than similar tumors in adults. Multifocal presentation is even less common than isolated HPC and hence its clinical and histologic recognition may be challenging. A newborn infant with multifocal congenital HPC causing severe deformity but with a favorable outcome after chemotherapy and surgical removal is reported. © 2016 Wiley Periodicals, Inc.

  13. Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up

    Directory of Open Access Journals (Sweden)

    Peter Mojzis

    2017-10-01

    Full Text Available AIM: To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens (IOL during a 12-month follow-up. METHODS: Prospective comparative study including 75 eyes of 38 patients (44-70y undergoing uneventful cataract surgery. Each patient was randomly assigned to one type of IOL, bifocal (35 eyes or trifocal (40 eyes. Visual, refractive, and contrast sensitivity changes were evaluated in a 12-month follow-up. The binocular defocus curve was also measured at 12mo postoperatively. RESULTS: No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities (P≥0.276. Postoperative corrected near visual acuity (33 cm was significantly better in the trifocal group during all follow-up (P≤0.004 as well as 6-month uncorrected near (P=0.008 and distance-corrected near visual acuities (P=0.016 (33/40 cm. Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group (P<0.001, which was consistent with differences among groups in binocular defocus curve. Differences among groups in contrast sensitivity were minimal, being only significant at 6 months for some low to medium spatial frequencies (P≤0.006. CONCLUSION: Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up, with a clear benefit of the trifocal IOL for the intermediate vision.

  14. Primary multifocal osseous lymphoma in a child

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takashi S.P. [University of Iowa, Carver College of Medicine, Iowa City, IA (United States); Ferguson, Polly J. [University of Iowa, Department of Pediatrics, Iowa City, IA (United States); Khanna, Geetika [Washington University, Mallinckrodt Institute of Radiology, St Louis, MO (United States)

    2008-12-15

    We report a case of primary multifocal osseous lymphoma in a 6-year-old girl presenting with multifocal osteolytic lesions without systemic symptoms or identifiable non-osseous primary tumor. The differential diagnoses for such a presentation include histiocytosis X, chronic recurrent multifocal osteomyelitis, acute lymphoblastic leukemia, metastatic disease, and primary bone lymphoma. Although non-Hodgkin lymphoma is common in the pediatric population, its presentation as a primary bone tumor, especially with multifocal disease, is extremely rare and is frequently misdiagnosed. We hope that awareness of this entity will help radiologists achieve timely diagnosis and intervention. (orig.)

  15. MANAGEMENT OF RESIDUAL REFRACTIVE ERROR AFTER CATARACT PHACOEMULSIFICATION. PART 2. INTRAOCULAR APPROACHES

    Directory of Open Access Journals (Sweden)

    K. B. Pershin

    2017-01-01

    Full Text Available The review presents an  analysis  of the  literature  data  on  the  methods of surgical  correction of residual  refractive  error after cataract phacoemulsification. Keratorefractive and intraocular approaches are  considered in details.  A comparison of the  efficacy and  safet y  of different groups   of methods on  the  example  of comparative studies is given.  Historically earlier  keratorefractive methods (laser  vision correction with LASIK and  PRK techniques on intact  eyes,  LASIK after  implantation  of multifocal  IOLs and arcuate keratotomy  after  phaco  are  indicated  for  the  correction of astigmatic refractive  error and  a small  spherical refractive error. Intraocular methods, including the  replacement of the  IOL  and  «piggyback» IOLs implantation  are  used  to  correct a large spherical refractive error. The introduction  of new  technology, the  implantation  of light-adjustable  IOLs, will  expand  the  existing evidence  and provide greater predictabilit y and efficiency of the  method  of correction of residual  refractive error.

  16. Multifocal osteogenic sarcoma in Paget's disease

    International Nuclear Information System (INIS)

    Vuillemin-Bodaghi, V.; Parlier-Cuau, C.; Laredo, J.D.; Cywiner-Golenzer, C.; Quillard, A.; Kaplan, G.

    2000-01-01

    The most serious complication of Paget's disease is sarcomatous degeneration of pagetic bone. Multifocal sarcomatous degeneration occurs mainly in polyostotic Paget's disease. Multifocal Paget's sarcoma is uncommon and can arise in any site. We report two cases of synchronous multifocal sarcomatous degeneration. The two patients were elderly women (aged 77 and 86 years, respectively) who developed sarcomatous lesions concomitantly, in the first case report in left ilium, left tibia, and first lumbar vertebra and in the second case report in the skull, right ilium, and sacrum. Whether these cases are due to the simultaneous development of several primaries or to metastases from a single primary remains unclear. (orig.)

  17. Progressive Multifocal Leukoencephalopathy

    Science.gov (United States)

    ... SEARCH Definition Treatment Prognosis Clinical Trials Organizations Publications Definition Progressive multifocal leukoencephalopathy (PML) is a disease of the white matter of the brain, caused by a virus infection ...

  18. Drug-induced progressive multifocal leukoencephalopathy

    DEFF Research Database (Denmark)

    Vermeer, N S; Straus, S M J M; Mantel-Teeuwisse, A K

    2015-01-01

    Progressive multifocal leukoencephalopathy (PML) has been identified as a serious adverse drug reaction (ADR) of several immunomodulatory biologicals. In this study, we contrasted the reporting patterns of PML for two biologicals for which the risk was identified at different points in their life......Progressive multifocal leukoencephalopathy (PML) has been identified as a serious adverse drug reaction (ADR) of several immunomodulatory biologicals. In this study, we contrasted the reporting patterns of PML for two biologicals for which the risk was identified at different points...

  19. Avaliação do desempenho visual da lente intraocular difrativa multifocal - Zeiss AT Lisa 809 MTM

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2014-04-01

    Full Text Available Objetivo: Avaliar a função visual dos pacientes com implante bilateral da LIO multifocal difrativa AT-Lisa 809 MTM por meio dos exames de acuidade visual com e sem correção óptica, curva de sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF39. Métodos: Estudo clínico, prospectivo e de intervenção, que avaliou os resultados de 20 olhos de 10 pacientes, submetidos à facoemulsificação e implante de LIO, entre fevereiro e junho de 2012. Resultados: A ametropia residual média pós-operatória foi de 0,05 ± 0,42 (-0,75 a +1,25 D dioptrias esféricas e -0,30 ± 0,42 (0 a -1,25 D dioptrias cilíndricas. Na curva de desenfoque mono e binocular, a melhor acuidade visual média obtida com 0.00 D de desenfoque (AV de longe. O segundo pico foi obtido com desenfoque de -3,00 D, o que equivale à visão de perto a 33 cm. Entre esses picos, observamos uma perda de desempenho visual, com desenfoque de -2,00 D, que equivale a visão intermediária a 50 cm. A sensibilidade ao contraste foi similar aos relatados na literatura com este tipo de LIO, tanto com quanto sem ofuscamento, e é mostrada em gráficos. O questionário de função visual (VFQ-39 teve valor médio de 91,91 +- 6,82. Conclusão: A LIO multifocal difrativa AT-Lisa 809MTM (Carl Zeiss Meditec Company - Alemanha apresentou resultados condizentes com a literatura quando avaliada pelos exames de acuidade visual com e sem correção óptica, sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF 39.

  20. Multi-focal Vision and Gaze Control Improve Navigation Performance

    Directory of Open Access Journals (Sweden)

    Kolja Kuehnlenz

    2008-11-01

    Full Text Available Multi-focal vision systems comprise cameras with various fields of view and measurement accuracies. This article presents a multi-focal approach to localization and mapping of mobile robots with active vision. An implementation of the novel concept is done considering a humanoid robot navigation scenario where the robot is visually guided through a structured environment with several landmarks. Various embodiments of multi-focal vision systems are investigated and the impact on navigation performance is evaluated in comparison to a conventional mono-focal stereo set-up. The comparative studies clearly show the benefits of multi-focal vision for mobile robot navigation: flexibility to assign the different available sensors optimally in each situation, enhancement of the visible field, higher localization accuracy, and, thus, better task performance, i.e. path following behavior of the mobile robot. It is shown that multi-focal vision may strongly improve navigation performance.

  1. Refractive Lens Exchange with Multifocal Intraocular Lens for Treatment of Chronic Intermittent Spasm of the Near Reflex

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2017-12-01

    Full Text Available We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20.

  2. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Vilar C

    2017-08-01

    Full Text Available César Vilar,1,2 Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 Klayny Rafaella Pereira Magalhães,2 Patrick Frensel de Moraes Tzelikis,1,2 Mario Augusto Pereira Dias Chaves,2,4 Antônio Francisco Pimenta Motta,2,3 Pedro Carlos Carricondo,1–3 Milton Ruiz Alves,3 Walton Nosé5 1Cataract Division, Brasília Ophthalmologic Hospital (HOB, Brasília-DF, Brazil; 2Renato Ambrosio Ophthalmologic Research Center (CEORA, 3Ophthalmology Department, São Paulo University – USP, São Paulo-SP, Brazil; 4Cataract Division, ProVisão, João Pessoa-PB, Brazil; 5Ophthalmology Department, Paulista Medical School – UNIFESP, São Paulo-SP, Brazil Purpose: To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.Methods: This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA and uncorrected intermediate (60 cm and near (at 40 cm visual acuity; contrast sensitivity (CS and visual defocus curve.Results: Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.Conclusion: Both lens combinations were able to provide good near, intermediate and distance vision

  3. Three-dimensional vectorial multifocal arrays created by pseudo-period encoding

    Science.gov (United States)

    Zeng, Tingting; Chang, Chenliang; Chen, Zhaozhong; Wang, Hui-Tian; Ding, Jianping

    2018-06-01

    Multifocal arrays have been attracting considerable attention recently owing to their potential applications in parallel optical tweezers, parallel single-molecule orientation determination, parallel recording and multifocal multiphoton microscopy. However, the generation of vectorial multifocal arrays with a tailorable structure and polarization state remains a great challenge, and reports on multifocal arrays have hitherto been restricted either to scalar focal spots without polarization versatility or to regular arrays with fixed spacing. In this work, we propose a specific pseudo-period encoding technique to create three-dimensional (3D) vectorial multifocal arrays with the ability to manipulate the position, polarization state and intensity of each focal spot. We experimentally validated the flexibility of our approach in the generation of 3D vectorial multiple spots with polarization multiplicity and position tunability.

  4. Desempenho visual dos pacientes pseudofácicos com diferentes lentes intraoculares

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2013-10-01

    Full Text Available OBJETIVO: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. MÉTODOS: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC-FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Todos os exames foram realizados com seis meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7±6,6 anos no grupo Tecnis, 63,1±4,4 anos no grupo Restor e 63,7±4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF. A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001. Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56. A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001. A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001. A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001. CONCLUSÃO: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações ópticas e melhor visão intermediária que o grupo Restor.

  5. Intraocular pressure reduction and regulation system

    Science.gov (United States)

    Baehr, E. F.; Burnett, J. E.; Felder, S. F.; Mcgannon, W. J.

    1979-01-01

    An intraocular pressure reduction and regulation system is described and data are presented covering performance in: (1) reducing intraocular pressure to a preselected value, (2) maintaining a set minimum intraocular pressure, and (3) reducing the dynamic increases in intraocular pressure resulting from external loads applied to the eye.

  6. Intraocular (Eye) Melanoma—Health Professional Version

    Science.gov (United States)

    Intraocular (uveal) melanoma of the uveal tract (iris, ciliary body, and choroid), though rare, is the most common primary intraocular malignancy in adults. Find evidence-based information on intraocular melanoma treatment.

  7. Does multifocal papillary micro-carcinoma require radioiodine ablation?

    International Nuclear Information System (INIS)

    Punda, A.; Markovic, V.; Eterovic, D.

    2015-01-01

    Full text of publication follows. Background: the thyroid carcinomas smaller than 1 cm (micro-carcinomas) comprise a significant fraction of papillary carcinomas. Excluding clinical micro-carcinomas, which present as metastatic disease, the micro-carcinomas diagnosed by ultrasound/FNAC or incidentally have very good prognosis. However, whether or not these papillary micro-carcinomas require post-surgical radioiodine ablation remains a matter of debate. Hypothesis: multi-focality is present in majority of clinical papillary micro-carcinomas and this characteristic can be used to identify the subset of non-clinical micro-carcinomas with greater malignant potential. Methods: the data on types of differentiated thyroid carcinomas diagnosed in the period 2008-2011 in the University Hospital Split were collected. Results: there were 359 patients with thyroid carcinoma, 329 (92%) of which had papillary carcinoma. About 61% (202/329) of papillary carcinomas were micro-carcinomas; most of them were diagnosed by ultrasound/FNAC (134/202= 66%), the rest were incidentalomas (48/202=24%) and clinical micro carcinomas (20/202=10%). Sixty percent (12/20) of patients with clinical micro-carcinoma and 23 patients with non-clinical micro-carcinoma (23/182=13%) had multifocal disease. Conclusion: multifocal disease is a frequent characteristic of clinical papillary thyroid micro-carcinomas, suggesting that multi-focality presents an early stage of non-clinical micro-carcinomas with more aggressive behaviour. Thus multifocal, but not uni-focal papillary micro-carcinomas may require radioiodine ablation. (authors)

  8. [Correlation of intraocular pressure variation after visual field examination with 24-hour intraocular pressure variations in primary open-angle glaucoma].

    Science.gov (United States)

    Noro, Takahiko; Nakamoto, Kenji; Sato, Makoto; Yasuda, Noriko; Ito, Yoshinori; Ogawa, Shumpei; Nakano, Tadashi; Tsuneoka, Hiroshi

    2014-10-01

    We retrospectively examined intraocular pressure variations after visual field examination in primary open angle glaucoma (POAG), together with its influencing factors and its association with 24-hour intraocular pressure variations. Subjects were 94 eyes (52 POAG patients) subjected to measurements of 24-hour intraocular pressure and of changes in intraocular pressure after visual field examination using a Humphrey Visual Field Analyzer. Subjects were classified into three groups according to the magnitude of variation (large, intermediate and small), and 24-hour intraocular pressure variations were compared among the three groups. Factors influencing intraocular pressure variations after visual field examination and those associated with the large variation group were investigated. Average intraocular pressure variation after visual field examination was -0.28 ± 1.90 (range - 6.0(-) + 5.0) mmHg. No significant influencing factors were identified. The intraocular pressure at 3 a.m. was significantly higher in the large variation group than other two groups (p field examination. Increases in intraocular pressure during the night might be associated with large intraocular pressure variations after visual field examination.

  9. Influence on Visual Quality of Intraoperative Orientation of Asymmetric Intraocular Lenses.

    Science.gov (United States)

    Bonaque-González, Sergio; Ríos, Susana; Amigó, Alfredo; López-Gil, Norberto

    2015-10-01

    To evaluate visual quality when changing the intraocular orientation of the Lentis Mplus LS-312MF nonrotational symmetric +3.00 diopters aspheric multifocal intraocular lens ([IOL] Oculentis GmbH, Berlin, Germany) in normal eyes. An artificial eye was used to measure the in vitro wavefront of the IOL. The corneal topography of 20 healthy patients was obtained. For each eye, a computational analysis simulated the implantation of the IOL. The modulation transfer function (MTF) and an image quality parameter (visually modulated transfer function [VSMTF] metric) were calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the IOL with respect to the cornea from 0° to 360° in 1° steps. Statistical analysis showed significant differences in mean VSMTF values between orientations for distance vision. Optimal orientation of the IOL (different for each eye) showed a mean improvement of 58% ± 19% (range: 20% to 121%) in VSMTF values with respect to the worst possible orientation. For these orientations, intermediate and near vision quality were statistically indistinguishable. The MTFs were different between orientations, showing a mean difference of approximately 5 cycles per degree in the maximum spatial frequencies that can be transferred between the best and the worst orientations for distance vision. The results suggest that implantation of this nonrotational symmetric IOL should improve visual outcomes if it is oriented to coincide with a customized meridian. A simple, practical method is proposed to find an approximation to the angle that an Mplus IOL should be inserted. Copyright 2015, SLACK Incorporated.

  10. Multifocal Epithelial Hyperplasia.

    Science.gov (United States)

    Agnew, Caitlin; Alexander, Sherene; Prabhu, Neeta

    2017-01-15

    Multifocal epithelial hyperplasia is a rare disease associated with human papilloma virus types 13 and 32. Diagnosis is based on clinical and histopathological findings, and most lesions are asymptomatic and regress spontaneously with time. The purpose of this paper is to describe a five-year-old girl who presented with multiple intraoral lesions on the buccal mucosa and tongue, which regressed spontaneously in 15 months.

  11. MULTIFOCAL CHOROIDITIS IN DISSEMINATED SPOROTRICHOSIS IN PATIENTS WITH HIV/AIDS.

    Science.gov (United States)

    Biancardi, Ana L; Freitas, Dayvison F S; Valviesse, Vitor R G de A; Andrade, Hugo B; de Oliveira, Manoel M E; do Valle, Antonio C F; Zancope-Oliveira, Rosely M; Galhardo, Maria C G; Curi, Andre L L

    2017-01-01

    In this article, the authors describe multifocal choroiditis related to disseminated sporotrichosis in patients with HIV/AIDS. We conducted a retrospective observational study of three patients infected with HIV who presented with disseminated sporotrichosis characterized by cutaneous lesions, multifocal choroiditis, and other manifestations, including osteomyelitis and involvement of the bone marrow, larynx, pharynx, and nasal and oral mucosa. Five eyes of three patients with HIV/AIDS showed multifocal choroiditis related to disseminated sporotrichosis. The CD4 counts ranged from 25 to 53 mm. All patients were asymptomatic visually. The ocular disease was bilateral in two patients. The lesion size ranged from 1/3 to 2 disc diameters. None of the patients had vitritis. Of the 12 lesions, 9 were localized in the posterior pole (Zone 1) and 3 were localized in the mild periphery (Zone 2). Multifocal choroiditis due to disseminated sporotrichosis can occur in profoundly immunosuppressed patients with HIV/AIDS.

  12. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    International Nuclear Information System (INIS)

    Spyratou, E.; Asproudis, I.; Tsoutsi, D.; Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A.

    2010-01-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV (λ = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  13. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    Energy Technology Data Exchange (ETDEWEB)

    Spyratou, E., E-mail: ellas5@central.ntua.gr [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece); Asproudis, I. [Department of Ophthalmology, University Hospital of Ioannina, Ioannina, 45110 (Greece); Tsoutsi, D. [Department of Chemistry, University of Ioannina, Ioannina, 45110 (Greece); Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A. [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece)

    2010-02-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV ({lambda} = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  14. Intraocular lymphoma

    Directory of Open Access Journals (Sweden)

    Li-Juan Tang

    2017-08-01

    Full Text Available Intraocular lymphoma (IOL is a rare lymphocytic malignancy which contains two main distinct forms. Primary intraocular lymphoma (PIOL is mainly a sub-type of primary central nervous system lymphoma (PCNSL. Alternatively, IOL can originate from outside the central nervous system (CNS by metastasizing to the eye. These tumors are known as secondary intraocular lymphoma (SIOL. The IOL can arise in the retina, uvea, vitreous, Bruch’s membrane and optic nerve. There are predominantly of B-cell origin; however there are also rare T-cell variants. Diagnosis remains challenging for ophthalmologists and pathologists, due to its ability to masquerade as noninfectious or infectious uveitis, white dot syndromes, or occasionally as other metastatic cancers. Laboratory tests include flow cytometry, immunocytochemistry, interleukin detection (IL-10: IL-6, ratio >1, and polymerase chain reaction (PCR amplification. Methotrexate-based systemic chemotherapy with external beam radiotherapy and intravitreal chemotherapy with methotrexate are useful for controlling the disease, but the prognosis remains poor. Therefore, it is important to make an early diagnose and treatment. This review is focused on the clinical manifestations, diagnosis, treatment and prognosis of the IOL.

  15. Multifocal hyperfunctioning thyroid carcinoma without metastases.

    Science.gov (United States)

    Nishida, Akiko T; Hirano, Shigeru; Asato, Ryo; Tanaka, Shinzo; Kitani, Yoshiharu; Honda, Nobumitsu; Fujiki, Nobuya; Miyata, Kouji; Fukushima, Hideyuki; Ito, Juichi

    2008-09-01

    Hyperthyroidism due to thyroid carcinoma is rare, and most cases are caused by hyperfunctioning metastatic thyroid carcinoma rather than primary carcinoma. Among primary hyperfunctioning thyroid carcinoma, multifocal thyroid carcinoma is exceedingly rare, with the only one case being reported in the literature. Here, we describe the case of a 62-year-old woman with multifocal functioning thyroid carcinoma. Technetium-99m (99m Tc) scintigraphic imaging showed four hot areas in the thyroid gland. Histopathological examination of all four nodules revealed papillary carcinoma, corresponding to hot areas in the 99m Tc scintigram. DNA sequencing of the thyrotropin receptor (TSH-R) gene from all nodules revealed no mutation, indicating that activation of TSH-R was unlikely in the pathophysiogenesis of hyperfunctioning thyroid carcinoma in the present case.

  16. Image quality comparison of two multifocal IOLs: influence of the pupil.

    Science.gov (United States)

    García-Domene, Mari Carmen; Felipe, Adelina; Peris-Martínez, Cristina; Navea, Amparo; Artigas, Jose M; Pons, Álvaro M

    2015-04-01

    To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany). The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques. In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL. The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm. Copyright 2015, SLACK Incorporated.

  17. A rare case of a medullary, multifocal lesion in the distal radius

    Science.gov (United States)

    Aktas, Birol; Ozturan, Burak; Kilic, Bulent; Ozkan, Korhan

    2017-01-01

    In multifocal findings, the possibility of multifocal osteoid osteomas should be considered and this case helps us to be attentive for the unusual radiographical presentation of osteoid osteoma. PMID:28748099

  18. Multifocal osteosarcoma as second tumor after childhood retinoblastoma

    International Nuclear Information System (INIS)

    Potepan, P.; Laffranchi, A.; Danesini, G.M.; Spagnoli, I.; Luksch, R.; Sozzi, G.; Testi, A.; Parafioriti, A.; Giardini, R.

    1999-01-01

    We present a case of multifocal osteosarcoma (MFOS) arising 11.5 years after successful treatment of bilateral retinoblastoma. The clinical, imaging and pathological findings at onset, after therapy, and during follow-up are described. Fluorescent in situ hybridization did not reveal a deletion of the RB-1 retinoblastoma gene, although the presence of an inactivating mutation invisible to this method cannot be ruled out. The MFOS may have been a second multifocal tumor associated with the original retinoblastoma or a post-irradiation sarcoma with extensive metastases. (orig.)

  19. A multifocal collimator with circularly distributed focal points for SPECT imaging

    International Nuclear Information System (INIS)

    Guillemaud, R.; Grangeat, P.

    1994-01-01

    The authors propose a new circular multifocal collimator which has multiple axial focal points distributed on a transverse circle. This distribution provides a strong focusing at the center of the detector like a cone-beam collimator, with a good sensitivity, and a weak transverse focusing at the periphery, to ensure acquisition of sufficient data, in order to prevent truncation artifacts. For a circular acquisition trajectory, each projection set of the multifocal geometry is equivalent to a virtual cone-beam projection set with a larger detector. Due to this equivalence, the authors derive a first solution for an analytical multifocal reconstruction algorithm: to rebin the projection set from multifocal to cone-beam geometry, then to use a 3D cone-beam reconstruction algorithm. The authors propose to use the Grangeat algorithm in order to deal with a large cone-beam aperture. Finally, the authors present results on simulated data for heart phantom, for a Defrise phantom and for a MTF study. The conclusion is that, from a multifocal projection set, objects are reconstructed without truncation artifacts, with a good precision at their center and with a loss of resolution at the periphery. In addition, the 3D cone-beam artifacts are reduced with the use of the Grangeat algorithm for the reconstruction step

  20. An Unusual Case of Unilateral Multifocal Choroiditis in a Young Male

    African Journals Online (AJOL)

    Multifocal choroiditis is a vision‑threatening disease causing inflammation at the level of retinal pigment epithelium and outer retina. We present a unique case of unilateral multifocal choroiditis in a young nonmyopic male and its subsequent course. The patient developed visual loss due to the sub‑retinal neovascular ...

  1. [Multifocal Electroretinography in Patients with Poppers Maculopathy].

    Science.gov (United States)

    Pahlitzsch, Milena; Salchow, Daniel; Rossel, Mirjam; Bergholz, Richard

    2017-10-12

    Background Maculopathy is a potential side effect of amyl nitrite or "poppers" abuse. It is characterized by a sudden, painless decrease in visual acuity. While the funduscopic changes are subtle, optical coherence tomography shows alterations of the outer retinal layers in the fovea. However, the extent of retinal dysfunction remains poorly understood. Materials/Methods We compared the multifocal electroretinogram of 6 patients with poppers maculopathy to that of a control group consisting of 6 healthy subjects. Response densities and implicit times of N1 and P1 were analyzed. Results Response densities and implicit times of both N1 and P1 were lower in the patients with poppers maculopathy than in the control group, particularly in ring 1 and rings 4 and 5. The only statistically significant finding, however, was a reduced N1 response density of one hexagon in the patient group. No significant differences were found considering the sum response or the averaged rings 1 to 5. Conclusion Compared to a healthy control group, the multifocal electroretinogram of patients with poppers maculopathy shows no relevant impairment. This contrasts the marked effect of the disease on visual acuity. In clinical practice, poppers maculopathy cannot be diagnosed by multifocal electroretinography. Georg Thieme Verlag KG Stuttgart · New York.

  2. Multifocal, chronic osteomyelitis of unknown etiology

    International Nuclear Information System (INIS)

    Kozlowski, K.; Beluffi, G.; Feltham, C.; James, M.; Nespoli, L.; Tamaela, L.; Pavia Univ.; Municipal Hospital, Nelson; Medical School, Jakarta

    1985-01-01

    Four cases of multifocal osteomyelitis of unknown origin in childhood are reported. The variable clinical and radiographic appearances of the disease are illustrated and the diagnostic difficulties in the early stages of the disease are stressed. (orig.) [de

  3. Progressive multifocal leukoencephalopathy in transplant recipients

    NARCIS (Netherlands)

    Mateen, Farrah J.; Muralidharan, RajaNandini; Carone, Marco; van de Beek, Diederik; Harrison, Daniel M.; Aksamit, Allen J.; Gould, Mary S.; Clifford, David B.; Nath, Avindra

    2011-01-01

    Transplant recipients are at risk of developing progressive multifocal leukoencephalopathy (PML), a rare demyelinating disorder caused by oligodendrocyte destruction by JC virus. Reports of PML following transplantation were found using PubMed Entrez (1958-July 2010). A multicenter, retrospective

  4. Power profiles of single vision and multifocal soft contact lenses.

    Science.gov (United States)

    Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A

    2015-02-01

    The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Taxonomy of multi-focal nematode image stacks by a CNN based image fusion approach.

    Science.gov (United States)

    Liu, Min; Wang, Xueping; Zhang, Hongzhong

    2018-03-01

    In the biomedical field, digital multi-focal images are very important for documentation and communication of specimen data, because the morphological information for a transparent specimen can be captured in form of a stack of high-quality images. Given biomedical image stacks containing multi-focal images, how to efficiently extract effective features from all layers to classify the image stacks is still an open question. We present to use a deep convolutional neural network (CNN) image fusion based multilinear approach for the taxonomy of multi-focal image stacks. A deep CNN based image fusion technique is used to combine relevant information of multi-focal images within a given image stack into a single image, which is more informative and complete than any single image in the given stack. Besides, multi-focal images within a stack are fused along 3 orthogonal directions, and multiple features extracted from the fused images along different directions are combined by canonical correlation analysis (CCA). Because multi-focal image stacks represent the effect of different factors - texture, shape, different instances within the same class and different classes of objects, we embed the deep CNN based image fusion method within a multilinear framework to propose an image fusion based multilinear classifier. The experimental results on nematode multi-focal image stacks demonstrated that the deep CNN image fusion based multilinear classifier can reach a higher classification rate (95.7%) than that by the previous multilinear based approach (88.7%), even we only use the texture feature instead of the combination of texture and shape features as in the previous work. The proposed deep CNN image fusion based multilinear approach shows great potential in building an automated nematode taxonomy system for nematologists. It is effective to classify multi-focal image stacks. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Heterogeneity of DNA methylation in multifocal prostate cancer.

    Science.gov (United States)

    Serenaite, Inga; Daniunaite, Kristina; Jankevicius, Feliksas; Laurinavicius, Arvydas; Petroska, Donatas; Lazutka, Juozas R; Jarmalaite, Sonata

    2015-01-01

    Most prostate cancer (PCa) cases are multifocal, and separate foci display histological and molecular heterogeneity. DNA hypermethylation is a frequent alteration in PCa, but interfocal heterogeneity of these changes has not been extensively investigated. Ten pairs of foci from multifocal PCa and 15 benign prostatic hyperplasia (BPH) samples were obtained from prostatectomy specimens, resulting altogether in 35 samples. Methylation-specific PCR (MSP) was used to evaluate methylation status of nine tumor suppressor genes (TSGs), and a set of selected TSGs was quantitatively analyzed for methylation intensity by pyrosequencing. Promoter sequences of the RASSF1 and ESR1 genes were methylated in all paired PCa foci, and frequent (≥75 %) DNA methylation was detected in RARB, GSTP1, and ABCB1 genes. MSP revealed different methylation status of at least one gene in separate foci in 8 out of 10 multifocal tumors. The mean methylation level of ESR1, GSTP1, RASSF1, and RARB differed between the paired foci of all PCa cases. The intensity of DNA methylation in these TSGs was significantly higher in PCa cases than in BPH (p epigenetic profile of recurrent tumors can be inferred from our data.

  7. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  8. Multifocal necrotizing fasciitis following Hirshsprung's disease ...

    African Journals Online (AJOL)

    Multifocal necrotizing fasciitis following Hirshsprung's disease surgery away from the surgical wound site. Ahmed A. Haseeb, Shadi Okasha and Atef Elbarawi. Necrotizing fasciitis (NF) is a life-threatening infection with rapidly progressive necrosis. Escherichia coli is rarely reported as causative agent of type 2 NF.

  9. Intraocular inflammation in autoimmune diseases.

    Science.gov (United States)

    Pras, Eran; Neumann, Ron; Zandman-Goddard, Gisele; Levy, Yair; Assia, Ehud I; Shoenfeld, Yehuda; Langevitz, Pnina

    2004-12-01

    The uveal tract represents the vascular organ of the eye. In addition to providing most of the blood supply to the intraocular structures, it acts as a conduit for immune cells, particularly lymphocytes, to enter the eye. Consequently, the uveal tract is represented in many intraocular inflammatory processes. Uveitis is probably a misnomer unless antigens within the uvea are the direct targets of the inflammatory process. A better term of the condition is "intraocular inflammation" (IOI). To review the presence of IOI in autoimmune diseases, the immunopathogenic mechanisms leading to disease, and treatment. We reviewed the English medical literature by using MEDLINE (1984-2003) employing the terms "uveitis," "intraocular inflammation," and "autoimmune diseases." An underlying autoimmune disease was identified in up to 40% of patients with IOI, and included spondyloarthropathies, Behcets disease, sarcoidosis, juvenile chronic arthritis, Vogt-Koyanagi-Harada syndrome (an inflammatory syndrome including uveitis with dermatologic and neurologic manifestations), immune recovery syndrome, and uveitis with tubulointerstitial disease. The immunopathogenesis of IOI involves enhanced T-cell response. Recently, guidelines for the use of immunosuppressive drugs for inflammatory eye disease were established and include: corticosteroids, azathioprine, methotrexate, mycophenolate mofetil, cyclosporine, tacrolimus, cyclophosphamide, and chlorambucil. New therapies with limited experience include the tumor necrosis factor alpha inhibitors, interferon alfa, monoclonal antibodies against lymphocyte surface antigens, intravenous immunoglobulin (IVIG), and the intraocular delivery of immunosuppressive agents. An underlying autoimmune disease was identified in up to 40% of patients with IOI. Immunosuppressive drugs, biologic agents, and IVIG are employed for the treatment of IOI in autoimmune diseases.

  10. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  11. 21 CFR 886.4275 - Intraocular fluid.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to aid... section 515 of the act is required before this device may be commercially distributed. See § 886.3. ...

  12. A Case Report of Intraocular Metastasis Treated with Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Bae; Byun, Sang Jun; Kim, Kwang Soo; Kim, Jin Hee [Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Ho Jun [Daegu Catholic University School of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    Intraocular metastasis is the most common malignancy of the eye. The frequency of intraocular metastasis in all the patients dying of cancer is about 12% and ocular metastases will be detected more frequently in the future because the patients with malignant tumor are now living longer. Intraocular metastasis can cause a serious clinical problem such as blindness. The early recognition and treatment of intraocular metastasis are very important clinical oncologic issues to maintain vision and to maximize the quality of life. However, significance of intraocular metastasis is still under-evaluated for practicing oncologists. External beam radiotherapy is a safe, effective palliative treatment in terms of preserving both the vision and the eye globe.

  13. 21 CFR 886.4270 - Intraocular gas.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place pressure... required. As of May 28, 1976, an approval under section 515 of the act is required before this device may...

  14. Comparison on the visual quality after different multifocal lens implantation in cataract patients

    Directory of Open Access Journals (Sweden)

    Si-Meng Qu

    2018-02-01

    Full Text Available AIM: To compare the visual quality after different multifocal lens(MIOLimplantation in cataract patients. METHODS:Totally 78 cases(78 eyesof cataract patients who receiving phacoemulsification and implantation of different MIOL were enrolled from February 2016 to June 2017 in our hospital. According to the different type of implanted MIOL, the 78 cases(78 eyeswere divided Group A, B and C, each group was 26 cases(26 eyes. Patients in the Group A were implanted regional refraction MIOL SBL-3; patients in the Group B implanted step progressive diffraction MIOL SN6AD1; patients in the Group C implanted all-optical plane diffraction MIOL Tecnis ZMB00. The visual acuity, contrast sensitivity, defocus testing, contrast visual acuity and satisfaction of visual quality were compared in 3 groups at postoperative 3mo. RESULTS: There was no statistically significant difference in postoperative adverse reactions between the three groups(P>0.05. There was statistical difference in uncorrected intermediate visual acuity, uncorrected near visual acuity, distance-corrected intermediate visual acuity and distance-corrected near visual acuity in 3 groups(PPPPPPPPPCONCLUSION:The region refraction MIOL SBL-3 not only could provide better distant, intermediate and near visual acuity, but also could provide better contrast sensitivity and contrast visual acuity, thereby greatly increase visual quality satisfaction.

  15. Contactin-1 and Neurofascin-155/-186 Are Not Targets of Auto-Antibodies in Multifocal Motor Neuropathy.

    Directory of Open Access Journals (Sweden)

    Kathrin Doppler

    Full Text Available Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.

  16. Effect of multizone refractive multifocal contact lenses on standard automated perimetry.

    Science.gov (United States)

    Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa

    2012-09-01

    The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.

  17. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  18. Multifocal tenosynovial giant cell tumors in a child with Noonan syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Arthur B. [Children' s Hospital of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Awomolo, Agboola O. [Children' s Hospital of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Szabo, Sara [Medical College of Wisconsin and Children' s Hospital of Wisconsin, Department of Pathology, Milwaukee, WI (United States); Cincinnati Children' s Hospital Medical Center, Division of Pathology and Laboratory Medicine, Cincinnati, OH (United States)

    2017-03-15

    Noonan syndrome is a genetic disorder with variable expression of distinctive facial features, webbed neck, chest deformity, short stature, cryptorchidism and congenital heart disease. The association of Noonan syndrome and giant cell granulomas of the mandible is widely reported. However, Noonan syndrome may also be associated with single or multifocal tenosynovial giant cell tumors, also referred to as pigmented villonodular synovitis. We report a child with Noonan syndrome, giant cell granulomas of the mandible and synovial and tenosynovial giant cell tumors involving multiple joints and tendon sheaths who was initially misdiagnosed with juvenile idiopathic arthritis. It is important for radiologists to be aware of the association of Noonan syndrome and multifocal giant cell lesions, which can range from the more commonly described giant cell granulomas of the mandible to isolated or multifocal intra- or extra-articular tenosynovial giant cell tumors or a combination of all of these lesions. (orig.)

  19. Multifocal tenosynovial giant cell tumors in a child with Noonan syndrome.

    Science.gov (United States)

    Meyers, Arthur B; Awomolo, Agboola O; Szabo, Sara

    2017-03-01

    Noonan syndrome is a genetic disorder with variable expression of distinctive facial features, webbed neck, chest deformity, short stature, cryptorchidism and congenital heart disease. The association of Noonan syndrome and giant cell granulomas of the mandible is widely reported. However, Noonan syndrome may also be associated with single or multifocal tenosynovial giant cell tumors, also referred to as pigmented villonodular synovitis. We report a child with Noonan syndrome, giant cell granulomas of the mandible and synovial and tenosynovial giant cell tumors involving multiple joints and tendon sheaths who was initially misdiagnosed with juvenile idiopathic arthritis. It is important for radiologists to be aware of the association of Noonan syndrome and multifocal giant cell lesions, which can range from the more commonly described giant cell granulomas of the mandible to isolated or multifocal intra- or extra-articular tenosynovial giant cell tumors or a combination of all of these lesions.

  20. Multifocal tenosynovial giant cell tumors in a child with Noonan syndrome

    International Nuclear Information System (INIS)

    Meyers, Arthur B.; Awomolo, Agboola O.; Szabo, Sara

    2017-01-01

    Noonan syndrome is a genetic disorder with variable expression of distinctive facial features, webbed neck, chest deformity, short stature, cryptorchidism and congenital heart disease. The association of Noonan syndrome and giant cell granulomas of the mandible is widely reported. However, Noonan syndrome may also be associated with single or multifocal tenosynovial giant cell tumors, also referred to as pigmented villonodular synovitis. We report a child with Noonan syndrome, giant cell granulomas of the mandible and synovial and tenosynovial giant cell tumors involving multiple joints and tendon sheaths who was initially misdiagnosed with juvenile idiopathic arthritis. It is important for radiologists to be aware of the association of Noonan syndrome and multifocal giant cell lesions, which can range from the more commonly described giant cell granulomas of the mandible to isolated or multifocal intra- or extra-articular tenosynovial giant cell tumors or a combination of all of these lesions. (orig.)

  1. Multifocal chronic osteomyelitis of unknown etiology

    International Nuclear Information System (INIS)

    Kozlowski, K.; Masel, J.; Harbison, S.; Yu, J.; Royal Brisbane Children Hospital; Regional Hospital Bowral

    1983-01-01

    Five cases of chronic, inflammatory, multifocal bone lesions of unknown etiology are reported. Although bone biopsy confirmed osteomyelitis in each case in none of them were organisms found inspite of an extensive work up. Different clinical course of the disease reflects different aetiology in respective cases. These cases present changing aspects of osteomyelitis emerging since introduction of antibiotics. (orig.)

  2. Preoperative automatic visual behavioural analysis as a tool for intraocular lens choice in cataract surgery

    Directory of Open Access Journals (Sweden)

    Heloisa Neumann Nogueira

    2015-04-01

    Full Text Available Purpose: Cataract is the main cause of blindness, affecting 18 million people worldwide, with the highest incidence in the population above 50 years of age. Low visual acuity caused by cataract may have a negative impact on patient quality of life. The current treatment is surgery in order to replace the natural lens with an artificial intraocular lens (IOL, which can be mono- or multifocal. However, due to potential side effects, IOLs must be carefully chosen to ensure higher patient satisfaction. Thus, studies on the visual behavior of these patients may be an important tool to determine the best type of IOL implantation. This study proposed an anamnestic add-on for optimizing the choice of IOL. Methods: We used a camera that automatically takes pictures, documenting the patient’s visual routine in order to obtain additional information about the frequency of distant, intermediate, and near sights. Results: The results indicated an estimated frequency percentage, suggesting that visual analysis of routine photographic records of a patient with cataract may be useful for understanding behavioural gaze and for choosing visual management strategy after cataract surgery, simultaneously stimulating interest for customized IOL manufacturing according to individual needs.

  3. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  4. A circular multifocal collimator for 3D SPECT imaging

    International Nuclear Information System (INIS)

    Guillemaud, R.; Grangeat, P.

    1993-01-01

    In order to improve sensitivity of 3D Single Photon Emission Tomography (SPECT) image, a cone-beam collimator can be used. A new circular multifocal collimator is proposed. The multiple focal points are distributed on a transaxial circle which is the trajectory of the focal points during the circular acquisition. This distribution provides a strong focusing at the center of the detector like a cone-beam collimator, with a good sensitivity, and a weak transaxial focusing at the periphery. A solution for an analytical multifocal reconstruction algorithm has been derived. Grangeat algorithm is proposed to use for this purpose in order to reconstruct with a good sensitivity the region of interest. (R.P.) 3 refs

  5. Multifocal epithelioid hemangioendothelioma of the phalanges of the hand

    International Nuclear Information System (INIS)

    Bruegel, Melanie; Waldt, Simone; Woertler, Klaus; Rummeny, Ernst J.; Weirich, Gregor

    2006-01-01

    Epithelioid hemangioendothelioma (EH) of bone is a rare vascular neoplasm characterized by epithelioid endothelial cells and a variable biologic behaviour. The principal sites of occurrence of this osteolytic tumor are the lower extremity and the axial skeleton. Approximately half of the cases present with multifocal disease. The latter feature can be helpful in suggesting the diagnosis of a vascular tumor; on the other hand, it strengthens the need for a skeletal survey or whole-body MRI/CT. We report on the clinical, histologic and radiologic features - including CT and MRI findings - of EH in a case of multifocal disease of the phalanges of the hand, a very uncommon anatomic site of affliction. (orig.)

  6. Research advances on multifocal electroretinogram in primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Feng-Fei Mo

    2013-10-01

    Full Text Available Primary open angle glaucoma is a chronic and progressive optic neuropathy. It can lead to serious damage of visual impairment, and it is an important eye disease of blindness. Multifocal electroretinogram is a new way to measure visual electrophysiology. It can measure electroretinogram of the whole visual field of many small parts in a relatively short period of time, and it can reflect the function of regional retina. It has an extremely important value for early diagnosis of primary open angle glaucoma. The research advances on multifocal electroretinogram in diagnosing primary open angle glaucoma were summarized in this paper.

  7. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  8. Does the apodized diffractive intraocular lens Acrysof ReSTOR NaturalTM interfere with FDT Matrix perimetry results? A lente difrativa apodizada Acrysof ReSTOR NaturalTM pode interferir nos resultados da perimetria por FDT Matrix?

    Directory of Open Access Journals (Sweden)

    Karine Duarte Bojikian

    2009-12-01

    Full Text Available PURPOSE: To compare the effect of an apodized diffractive intraocular lens (IOL (Acrysof ReSTOR NaturalTM and its yellow counterpart (Natural IQ TM on frequency doubling technology (FDT perimetry results. METHODS: This study included 37 eyes from 22 patients at the "Centro Oftalmológico Tranjan" who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM performed by the same surgeon, at least three months prior to the study. Patients were subject to frequency doubling technology Matrix Perimeter testing. RESULTS: The patients were between 41 to 79 years old (mean, 70.78 ± 9.83 in the Natural IQ TM and 49 to 81 years old (mean, 67.11± 11.48 in the Acrysof ReSTOR NaturalTM group, and the mean IOP was 13.64 ± 2.02 mmHg in the Natural IQ TM 12.94 ± 1.39 mmHg in the Acrysof ReSTOR NaturalTM group. The mean pupillary diameter under scotopic conditions was 6.63 ± 1.16 mm in the Natural IQ TM group and 7.20 ± 1.8 mm in the Acrysof ReSTOR NaturalTM group (p=0.20. The mean deviation was -1.83 ± 3.46 dB in the Natural IQ TM group and -1.77 ± 3.94 dB in the Acrysof ReSTOR NaturalTM group (p=0.28. The pattern standard deviation was 3.49 ± 0.79 dB in the Natural IQ TM group and 3.20 ± 0.86 dB in the Acrysof ReSTOR NaturalTM group (p=0.27. CONCLUSION: There was no difference in the results of FDT Matrix perimetry in eyes that received apodized diffractive IOLs implant or eyes that received monofocal intraocular lens implant.OBJETIVO: Comparar o efeito da lente difrativa apodizada (Acrysof ReSTOR NaturalTM e da lente de mesma plataforma amarela (Natural IQ TM sobre os resultados da perimetria de dupla frequência (FDT. MÉTODOS: O estudo incluiu 37 olhos de 22 pacientes do Centro Oftalmológico Tranjan que foram submetidos a cirurgia de facoemulsificação e implante de lentes intraoculares (17 Acrysof ReSTOR NaturalTM, 20 Natural IQ TM sem complicações, realizadas pelo mesmo

  9. Multifocal fibrosclerosis: a new case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Oguz, Kader Karli; Oguz, Oguzhan; Cila, Aysenur; Oto, Aytekin [Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Kiratli, Hayyam [Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Gokoz, Aytac [Department of Pathology, Faculty of Medicine, Hacettepe University, Ankara (Turkey)

    2002-05-01

    A case of multifocal fibrosclerosis is presented with MR images. Bilateral sclerosing orbital pseudotumor invading cavernous sinuses were the presenting disorder. Magnetic resonance imaging showed involvement of paranasal sinuses bilaterally and multiple supratentorial dural masses. Retroperitoneal fibrosis was associated with the condition. Multifocal involvement should be considered in patients with sclerosing orbital pseudotumor and an imaging approach should be performed on the appropriate clinical condition to document possible coexistence of other disorders including retroperitoneal fibrosis, mediastinal fibrosis, sclerosing cholangitis, and Riedel's thyroiditis (orig.)

  10. Multifocality as a prognostic factor in breast cancer patients registered in Danish Breast Cancer Cooperative Group (DBCG) 1996-2001

    DEFF Research Database (Denmark)

    Joergensen, L.E.; Gunnarsdottir, K.A.; Lanng, C.

    2008-01-01

    The purpose of this study was to investigate the prognostic influence of multifocality in breast cancer patients. In a cohort of 7196 patients there were 945 patients with multifocality. We found no prognostic influence of multifocality on overall survival when controlling for known prognostic......, Gunnarsdottir KA, Rasmussen BB, Moeller S, Lanng C. The prognostic influence of multifocality in breast cancer patients. Breast 2004;13:188-193]....... factors. We found a small but significant influence on disease-free survival (HR=1.16 [1.03-1.31]) and a strong correlation between multifocality and known prognostic factors. This was in accordance with an earlier study done on a smaller population and in a different period of time [Pedersen L...

  11. MULTIFOCAL RETINAL INFILTRATES WITH PHLEBITIS AND OPTIC NEUROPATHY IN AN HIV-POSITIVE PEDIATRIC PATIENT.

    Science.gov (United States)

    Kasi, Sundeep K; Vora, Robin A; Martin, Taliva; Cunningham, Emmett T

    2015-01-01

    To describe an unusual presentation of bilateral HIV-associated multifocal retinal infiltrates with phlebitis and optic neuropathy in a pediatric patient from Zimbabwe, Africa. Retrospective case report of a 15-year-old boy from Zimbabwe, Africa. The patient was found to have bilateral vitritis, multifocal retinitis with phlebitis, and optic neuropathy in the setting of previously unrecognized HIV infection. Vision improved and the clinical findings resolved after treatment with intravenous corticosteroids and highly active retroviral therapy (HAART). The authors describe the occurrence and treatment of bilateral, HIV-associated multifocal retinal infiltrates with phlebitis and HIV-associated optic neuropathy in a pediatric patient from Zimbabwe, Africa.

  12. Long-Term Visual Prognosis of Peripheral Multifocal Chorioretinitis

    NARCIS (Netherlands)

    Ossewaarde-van Norel, J; ten Dam-van Loon, NH; de Boer, JH; Rothova, A.

    2015-01-01

    Purpose To report on the clinical manifestations, complications, and long-term visual prognosis of patients with peripheral multifocal chorioretinitis and to search for predictors for a lower visual outcome. Design Retrospective consecutive observational case series. Methods setting: Institutional.

  13. A Rare Case of Multifocal Prostatic Blue Nevus

    Directory of Open Access Journals (Sweden)

    Elias J. Farran

    2018-01-01

    Full Text Available Prostatic blue nevus is a rare benign pathologic diagnosis most commonly diagnosed incidentally on many different types of prostate specimens. Blue nevus is the deposition of stromal melanin characterized by spindle cells within the fibromuscular stroma which stains positive for melanin-specific stains Fontana-Masson and S100 and stains negative for CD68, HMB45, and iron stains. We report the case of a multifocal and bilateral blue nevus in a 52-year-old Hispanic male who presented with an elevated prostate-specific antigen of 4.3 and mild obstructive lower urinary tract symptoms, found by transrectal ultrasound-guided prostate needle biopsy. The biopsy also revealed benign prostatic tissue with postatrophic hyperplasia and chronic inflammation. This is the 35th reported case of prostatic blue nevus and the third to show multifocal blue nevus.

  14. Relation between intraocular pressure and size of transverse sinuses

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan [Atatuerk University, Department of Radiology, Medical Faculty, Erzurum (Turkey); Dane, Senol; Gumustekin, Kenan [Atatuerk University, Department of Physiology, Medical Faculty, Erzurum (Turkey); Aslankurt, Murat [Atatuerk University, Department of Ophtalmatology, Medical Faculty, Erzurum (Turkey); Yazici, Ahmet Taylan [Beyoglu Goez Egitim ve Arastirma Hastanesi, Istanbul (Turkey)

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean{+-}SD; 19.72{+-}0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  15. Relation between intraocular pressure and size of transverse sinuses

    International Nuclear Information System (INIS)

    Kantarci, Mecit; Onbas, Omer; Alper, Fatih; Okur, Adnan; Dane, Senol; Gumustekin, Kenan; Aslankurt, Murat; Yazici, Ahmet Taylan

    2005-01-01

    There are asymmetries in the sizes of transverse sinus and intraocular pressure. The purpose of this study was to investigate possible relationships between the asymmetry of transverse sinuses in TOF MR venography and intraocular pressures of right and left eyes. In this study, subjects were 63 male and 42 female medical school students, aged 18-21 years (mean±SD; 19.72±0.67 years). Subjects with neurological and ophthalmologic disease, particularly dural sinus thrombosis, myopia, trauma and glaucoma, were excluded the study. Subjects were divided into five groups according to the magnitudes of the right- and left-transverse sinuses in MR venography results. There is a functional relation between intraocular pressures of the right and left eyes and asymmetry of the transverse sinus. If the transverse sinus on one side is larger and its venous drainage is greater, the intraocular pressure of the eye on this side is lower. It can be speculated that the transverse sinus size may be associated with pathogenesis of diseases with increased intraocular pressure such as glaucoma. We aim to determine the relation between the size and drainage of transverse sinuses in TOF MR venography and intraocular pressure in patients with open-angle glaucoma in our next study. (orig.)

  16. Acute Retention of Urine Following Intraocular Surgery | Nwosu ...

    African Journals Online (AJOL)

    Hyperosmolar agents and carbonic anhydrase inhibitors are used to lower the intraocular pressure and thus minimize the chances of vitreous loss during intraocular surgery. However, these agents could precipitate urinary retention. This is a report on two elderly men who had perioperative acute urinary retention following ...

  17. Intraocular osseous metaplasia. A clinico-pathological study

    OpenAIRE

    Vemuganti Geeta; Honavar Santosh; Jalali Subhadra

    2002-01-01

    Purpose: To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Methods: Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membra...

  18. Resultados da troca de lente intra-ocular de hidrogel opacificada

    Directory of Open Access Journals (Sweden)

    Salera Cristina Moreira

    2004-01-01

    Full Text Available OBJETIVO: Avaliar os resultados da explantação e substituição das lentes intra-oculares (LIO de hidrogel opacificadas. MÉTODOS: Foram analisados retrospectivamente os prontuários de 12 pacientes (15 olhos submetidos à explantação e substituição das lentes intra-oculares de hidrogel opacificadas. RESULTADOS: A opacificação das lentes intra-oculares de hidrogel causou perdas de linhas de visão em 13 olhos (86,7%. A troca das lentes intra-oculares opacificadas promoveu o ganho de linhas de visão em 11 olhos (73,3%. As complicações peroperatórias ocorreram em três olhos (20% e foram as seguintes: perda de óleo de silicone, ruptura total de zônula com perda do saco capsular e ruptura parcial de zônula. Durante a explantação das lentes intra-oculares foi necessária a realização de incisões relaxantes na borda da capsulorrexe anterior em três olhos (20% e em dois olhos (13,3% os hápticos foram cortados sendo retirada somente a zona óptica das lentes intra-oculares. CONCLUSÃO: A cirurgia para explantação e substituição das lentes intra-oculares opacificadas mostrou-se eficaz naqueles pacientes com perdas de linhas de visão (p > 0,05.

  19. Importance of intraocular pressure in glaucoma

    Science.gov (United States)

    Joos, Karen M.

    1999-06-01

    Glaucoma results in permanent vision loss and affects the peripheral vision initially. It is presented in 22.5 million people worldwide and is the 3rd cause of blindness. Present tonometers are not ideal for intraocular pressure measurements in all eyes. Of concern, PRK and LASIK may result in lower intraocular pressure readings. A challenges now exists for the development of a tonometer which can easily compensate for corneas with many parameters to avoid a future increase in normal-tension glaucoma or glaucoma which is advanced.

  20. Solid intraocular xanthogranuloma in three Miniature Schnauzer dogs.

    Science.gov (United States)

    Zarfoss, Mitzi K; Dubielzig, Richard R

    2007-01-01

    Macrophages that contain abundant intracytoplasmic lipid are called 'foam cells'. In four canine globes submitted to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW), foam cells formed a solid intraocular mass. The purpose of this study was to describe the histopathologic findings in these cases. The electronic COPLOW database (1993-2006) was searched for the diagnosis of 'foam cell tumor'. Clinical history, gross pathology and histopathology (5-micron sections, hematoxylin and eosin and Alcian blue periodic acid Schiff) were reviewed in all cases. Cases were included if the globe was grossly filled by a solid mass and if all intraocular structures were effaced by lipid-laden foam cell macrophages admixed with birefringent, Alcian blue-positive crystals oriented in stellate patterns. All three patients (four globes) satisfying the selection criteria were Miniature Schnauzers. In all cases the clinical history included diabetes mellitus, hyperlipidemia and chronic bilateral uveitis that was interpreted to be lens-induced. All globes were enucleated because of glaucoma. The term solid intraocular xanthogranuloma was used to describe these cases because the intraocular contents were effaced by a solid mass of foam cells and birefringent crystals. The cases in this report suggest that diabetic Miniature Schnauzers with hyperlipidemia are at risk for lipid and macrophage-rich uveitis, which may in some cases form a solid inflammatory intraocular mass, precipitate glaucoma, and lead to enucleation.

  1. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    2017-10-01

    Full Text Available AIM: To evaluate the refractive correction for standard automated perimetry (SAP in eyes with refractive multifocal contact lenses (CL in healthy young participants. METHODS: Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline; multifocal CL corrected for distance (mCL-D; and mCL-D corrected for near vision using a spectacle lens (mCL-N. Primary outcome measures were the foveal threshold, mean deviation (MD, and pattern standard deviation (PSD. RESULTS: The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB CONCLUSION: Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  2. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  3. Resultados de implante de lente intraocular en niños Results of intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Nashelly I. Mejía Cruz

    2007-12-01

    Full Text Available En este estudio se describen los resultados obtenidos del implante de lente intraocular en niños, quienes acudieron al servicio de Oftalmología Pediátrica de Instituto Cubano de oftalmología “Ramón Pando Ferrer” con el diagnóstico de catarata de diversas etiologías, en período comprendido entre abril del 2002 al 2005 cuyo seguimiento fue durante un año. En nuestro universo de estudio se determinan algunos parámetros como la edad del paciente, etiología de las cataratas, agudeza visual, defecto refractivo preoperatorio y posoperatorio. Se identificó el poder dióptrico del lente intraocular más frecuente, la presencia de complicaciones durante la cirugía y después de esta. Se evaluaron finalmente, los pacientes que requerían de tratamiento adicional como la capsulotomía con láser o membranectomía quirúrgica. El implante del lente intraocular a temprana edad se relacionó con buenos resultados quirúrgicos: mejoría de la agudeza visual corregida, presentándose el astigmatismo como el error refractivo más frecuente. La complicación transoperatorio y postoperatoria más frecuente fue la membrana inflamatoria, mientras que la complicación posoperatoria más frecuente fue la opacidad de la cápsula posterior.This paper described the results of the intraocular lens implantation performed in children, who had been seen at the Pediatric Ophthalmologic Service of " Ramon Pando Ferrer " Cuban Institute of Ophthalmology and had been diagnosed as having cataract of various etiologies, from April 2002 to April 2005. They were all followed-up for a year. Some parameters like the patient’s age, the etiology of cataract, visual acuity, pre-operative and post-operative refractive defect were considered in our study. The dioptric power of the most common intraocular lens and the most frequent complications during and after surgery were identified. The patients requiring additional treatment such as laser capsulotomy and surgical

  4. Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2017-06-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin2 1IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To compare two different diffractive trifocal intraocular lens (IOL designs, evaluating longer-term refractive outcomes, visual acuity (VA at various distances, low contrast VA and quality of vision.Patients and methods: Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX] were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m, intermediate (80 and 60 cm and near (40 cm. A binocular defocus curve was collected with the subject’s best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire.Results: Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of −1.0 D (FV better, P=0.02, −1.5 and −2.00 D (PX better, P<0.01 for both. Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm (P<0.01 with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens (P=0.04. There were no statistically significant differences by lens for low contrast VA (P=0.1 or for quality of vision measures (P>0.3.Conclusion: Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs

  5. Multifocal peritoneal splenosis in Tc-99m-labeled heat-denatured red blood cell scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Min Ki; Hwang, Kyung Hoon; Choe, Won Sick [Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2006-06-15

    A 44-year-old man with a past medical history of splenectomy came to hospital because of epigastric pain abdominopelvic computed tomography(CT) showed a soft tissue mass and multifocal variable-sized nodules as well as finding suggestive of cholecystitis. Subsequently, he underwent Tc-99m-labeled heat- denatured red blood cell(RBC) scintigraphy to evaluate the mass and nodules. The scintigraphy confirmed multifocal peritoneal splenosis in the abdominopelvic cavity.

  6. The Clinical and Molecular Characteristics of Adenocarcinoma Presented 
by Multi-focal GGO

    Directory of Open Access Journals (Sweden)

    Yang SONG

    2018-03-01

    Full Text Available Due to emphasis on early screening for lung cancer, the detection rate of multiple ground glass opacities (GGOs on computed tomography (CT image increases in recent years, and research on multifocal adenocarcinomas presented by GGOs has been thriving. It is more common in women and non-smokers and has excellent prognosis both in patients with natural history and after surgery. These clinical features suggest that it is likely to be a distinct disease entity. From the perspective of molecular genetics, lesions in the same individual are likely to have distinct clonal features. Therefore, genetic heterogeneity is the most prominent feature of multifocal pulmonary adenocarcinomas with GGOs. The genetic heterogeneity is expected to assist the diagnosis of multifocal pulmonary adenocarcinoma and intrapulmonary metastasis, and also suggests that genetic testing of the GGO lesions is of great therapeutic significance. Some GGO lesions may harvest the similar clonal feature, which provide new evidence for the theory of spread through air spaces (STAS.

  7. [The Clinical and Molecular Characteristics of Adenocarcinoma Presented 
by Multi-focal GGO].

    Science.gov (United States)

    Song, Yang; Liang, Naixin; Li, Shanqing

    2018-03-20

    Due to emphasis on early screening for lung cancer, the detection rate of multiple ground glass opacities (GGOs) on computed tomography (CT) image increases in recent years, and research on multifocal adenocarcinomas presented by GGOs has been thriving. It is more common in women and non-smokers and has excellent prognosis both in patients with natural history and after surgery. These clinical features suggest that it is likely to be a distinct disease entity. From the perspective of molecular genetics, lesions in the same individual are likely to have distinct clonal features. Therefore, genetic heterogeneity is the most prominent feature of multifocal pulmonary adenocarcinomas with GGOs. The genetic heterogeneity is expected to assist the diagnosis of multifocal pulmonary adenocarcinoma and intrapulmonary metastasis, and also suggests that genetic testing of the GGO lesions is of great therapeutic significance. Some GGO lesions may harvest the similar clonal feature, which provide new evidence for the theory of spread through air spaces (STAS).
.

  8. The effect of intraocular gas and fluid volumes on intraocular pressure.

    Science.gov (United States)

    Simone, J N; Whitacre, M M

    1990-02-01

    Large increases in the intraocular pressure (IOP) of postoperative gas-containing eyes may require the removal of gas or fluid to reduce the IOP to the normal range. Application of the ideal gas law to Friedenwald's equation provides a mathematical model of the relationship between IOP, intraocular gas and fluid volumes, and the coefficient of scleral rigidity. This mathematic model shows that removal of a given volume of gas or fluid produces an identical decrease in IOP and that the more gas an eye contains, the greater the volume reduction necessary to reduce the pressure. Application of the model shows that the effective coefficient of scleral rigidity is low (mean K, 0.0021) in eyes with elevated IOP that have undergone vitrectomy and retinal cryopexy and very low (mean K, 0.0013) in eyes with elevated IOP that have undergone placement of a scleral buckle and band. By using the appropriate mean coefficient of rigidity, the volume of material to be aspirated to produce a given decrease in IOP can be predicted with clinically useful accuracy.

  9. Commercial air travel after intraocular gas injection.

    Science.gov (United States)

    Houston, Stephen; Graf, Jürgen; Sharkey, James

    2012-08-01

    Passengers with intraocular gas are at risk of profound visual loss when exposed to reduced absolute pressure within the cabin of a typical commercial airliner. Information provided on the websites of the world's 10 largest airlines offer a considerable range of opinion as to when it might be safe to fly after gas injection. Physicians responsible for clearing pseassengers as 'fit to fly' should be aware modern retinal surgical techniques increasingly employ long-acting gases as vitreous substitutes. The kinetics of long-acting intraocular gases must be considered when deciding how long after surgery it is safe to travel. It is standard practice to advise passengers not to fly in aircraft until the gas is fully resorbed. To achieve this, it may be necessary to delay travel for approximately 2 wk after intraocular injection of sulfur hexafluoride (SF6) and for 6 wk after injection of perfluoropropane (C3F8).

  10. Determining the origin of synchronous multifocal bladder cancer by exome sequencing

    International Nuclear Information System (INIS)

    Acar, Ömer; Özkurt, Ezgi; Demir, Gulfem; Saraç, Hilal; Alkan, Can; Esen, Tarık; Somel, Mehmet; Lack, Nathan A.

    2015-01-01

    Synchronous multifocal tumours are commonly observed in urothelial carcinomas of the bladder. The origin of these physically independent tumours has been proposed to occur by either intraluminal migration (clonal) or spontaneous transformation of multiple cells by carcinogens (field effect). It is unclear which model is correct, with several studies supporting both hypotheses. A potential cause of this uncertainty may be the small number of genetic mutations previously used to quantify the relationship between these tumours. To better understand the genetic lineage of these tumours we conducted exome sequencing of synchronous multifocal pTa urothelial bladder cancers at a high depth, using multiple samples from three patients. Phylogenetic analysis of high confidence single nucleotide variants (SNV) demonstrated that the sequenced multifocal bladder cancers arose from a clonal origin in all three patients (bootstrap value 100 %). Interestingly, in two patients the most common type of tumour-associated SNVs were cytosine mutations of TpC* dinucleotides (Fisher’s exact test p < 10 −41 ), likely caused by APOBEC-mediated deamination. Incorporating these results into our clonal model, we found that TpC* type mutations occurred 2-5× more often among SNVs on the ancestral branches than in the more recent private branches (p < 10 −4 ) suggesting that TpC* mutations largely occurred early in the development of the tumour. These results demonstrate that synchronous multifocal bladder cancers frequently arise from a clonal origin. Our data also suggests that APOBEC-mediated mutations occur early in the development of the tumour and may be a driver of tumourigenesis in non-muscle invasive urothelial bladder cancer. The online version of this article (doi:10.1186/s12885-015-1859-8) contains supplementary material, which is available to authorized users

  11. Intraocular Inflammation Associated with Ocular Toxoplasmosis : Relationships at Initial Examination

    NARCIS (Netherlands)

    Dodds, Emilio M.; Holland, Gary N.; Stanford, Miles R.; Yu, Fei; Siu, Willie O.; Shah, Kayur H.; Loon, Ninette Ten Dam-Van; Muccioli, Cristina; Hovakimyan, Anna; Barisani-Asenbauer, Talin

    2008-01-01

    PURPOSE: To describe characteristics of intraocular inflammation in eyes with active ocular toxoplasmosis and to identify relationships between signs of inflammation, complications (including elevated intraocular pressure [IOP]), other disease features, and host characteristics. DESIGN: Multicenter,

  12. Unusually high incidence of multifocal epithelial hyperplasia in children of the Nahuatl population of Mexico.

    Science.gov (United States)

    Ledesma-Montes, Constantino; Mendez-Mendoza, Amilcar

    2017-01-01

    Multifocal epithelial hyperplasia is an uncommon disease of the oral mucosa caused by the human papilloma virus. To study the clinical and pathological findings of multifocal epithelial hyperplasia detected during an oral examination of 343 Mexican Nahuatl children from a single primary school in El Paso de Cupilco, Mexico. A thorough oral examination was performed in all children and clinical data (age, gender, location and number of lesions) were documented and analyzed. Multifocal epithelial hyperplasia was diagnosed in 110 of the 343 children (32.3%). The ages of the children varied from 5 to 15 years, and of these, 56.3% were girls. The lesions were asymptomatic, 0.2 to 3.0 cm in diameter, soft, round to oval, smooth surfaced, sessile papulonodules, similar in colour to that of the surrounding mucosa. The lesions were commonly seen on the buccal mucosa and tongue, and most affected children (85%) had less than 5 lesions. Children in the 7 to 10 years age group were most often affected. Human papillomavirus typing was not done owing to a lack of facilities. There is a high incidence of multifocal epithelial hyperplasia in Nahuatl children with a predilection for females.

  13. Basic characterization of normal multifocal electroretinogram

    International Nuclear Information System (INIS)

    Fernandez Cherkasova, Lilia; Rojas Rondon, Irene; Castro Perez, Pedro Daniel; Lopez Felipe, Daniel; Santiesteban Freixas, Rosaralis; Mendoza Santiesteban, Carlos E

    2008-01-01

    A scientific literature review was made on the novel multifocal electroretinogram technique, the involved cell mechanisms and some of the factors modifying its results together with the form of presentation. The basic characteristics of this electrophysiological record obtained from several regions of the retina of normal subjects is important in order to create at a small scale a comparative database to evaluate pathological eye tracing. All this will greatly help in early less invasive electrodiagnosis of localized retinal lesions. (Author)

  14. Toric Intraocular Lens Outcomes in Patients With Glaucoma.

    Science.gov (United States)

    Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G

    2015-06-01

    To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.

  15. A Rare Multifocal Pattern of Type 2 Autoimmune Pancreatitis with Negative IgG4: A Potential Diagnostic Pitfall That May Mimic Multifocal Pancreatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Partha Hota

    2018-02-01

    Full Text Available Autoimmune pancreatitis (AIP is an increasingly recognized form of acute pancreatitis characterized by obstructive jaundice with a rapid and dramatic treatment response to steroid therapy. Recently, AIP has been divided into two distinct phenotypes: lymphoplasmocytic sclerosing pancreatitis AIP (type 1 and idiopathic duct-centric pancreatitis AIP (type 2; each of which have their own distinct demographics, diagnostic criteria, and histopathological features. We report, to the best of our knowledge, the first case of a multifocal pattern of type 2 AIP characterized with both CT and MR imaging. This rare imaging pattern of AIP may mimic the appearance of more worrisome malignant etiologies such as multifocal pancreatic adenocarcinoma or lymphoma, with overlapping imaging characteristics potentially complicating or delaying diagnosis. Therefore, recognition of this atypical pattern of AIP and avoidance of this potential diagnostic pitfall is crucial.

  16. Multifocal Langerhans cell sarcoma involving epidermis: a case report and review

    Directory of Open Access Journals (Sweden)

    Wang Changsong

    2012-08-01

    Full Text Available Abstract Objective To study the clinico-pathological characteristics of Langerhans cell sarcoma (LCS which involving epidermis. Methods A case of primary multifocal LCS was analyzed in histopathology and immunophenotype. Results A 41-year-old man with multifocal cutaneous LCS involving the inguina and waist was reported. Clinical and pathology data were available. Neoplastic cells with markedly malignant cytological features were observed. Tumor cells exhibited irregular shape with abundant and eosinophilic red staining cytoplasm; large, irregular-shaped, showing lobulated or dented nucleus and some cells with a longitudinal nuclear groove and prominent nucleoli. The tumor cells expressed CD1a, Langerin (CD207, S-100 protein, CD68 and vimentin, and did not express pan-T or B cell markers and epithelial markers. The patient died less than 1 year after diagnosis due to local recurrence and metastasis to the lung, despite the administration of local radiation and chemotherapy. Conclusions LCS is a tumor with markedly malignant cytological features that originates from Langerhans cells. Primary multifocal neoplasms involving epidermis is even rare. Accurate diagnosis is based on the histopathological and immunohistochemical of the tumor cells. Virtual slide The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1182345104754765.

  17. Effect of plasma colloid osmotic pressure on intraocular pressure during haemodialysis

    OpenAIRE

    Tokuyama, T.; Ikeda, T.; Sato, K.

    1998-01-01

    BACKGROUND—In a previous case report, it was shown that an increase in plasma colloid osmotic pressure induced by the removal of fluid during haemodialysis was instrumental in decreasing intraocular pressure. The relation between changes in intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight before and after haemodialysis is evaluated.
METHODS—Intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight were evaluated before a...

  18. Indocyanine Green Angiographic and Multifocal Electroretinographic Features in the Diffuse and Regional Form of Bietti′s Crystalline Retinopathy

    Institute of Scientific and Technical Information of China (English)

    Libin Jiang; Feng Wen; Lezheng Wu; Hong Yan; Shixing Hu

    2002-01-01

    Prpose: To observe different features of indocyanine green angiography(ICGA) andtifocal electroretinography (ERG) in the diffuse and regional type of Bieti′sc stalline retinopathy (BCR). Thods: ICGA and the multifocal ERG were performed in two cases of the diffuse andregional type of BCR respectively. These data were compared with fluoresceinangiography (FA), standard Ganzfeld ERG, and visual field testing. Results: In the regional case, ICGA revealed reduced perfusion of the choroidalcirculation in the early phase and multiple hypofluorescent spots in the posterior pole in the late phase, due to choriocapillaris filling defect; the extent of choroiocapillaris losswas shown in early phase of ICGA and there were multifocal hyperfluorescent dotssurrounding hypofluorescent spots in late phase in the diffuse case. The multifocal ERGshowed that the central responses were markedly depressed, corresponding to the visualfield defects, while the findings of Ganzfeld ERG were normal in the regional BCR;however, both the multifocal ERG and Ganzfeld ERG were severely subnormal in thediffuse case.Conclusions: The features of ICGA and multifocal ERG are different between the diffuseand regional BCR. In the meantime, the two tools are also useful to differentiate the typeand assess the extentof evolution in BCR.

  19. clinical and experimental study

    OpenAIRE

    Tornow, Christoph

    2011-01-01

    Posterior capsule opacity (PCO) is a frequent complication in extracapsular cataract extraction in conjunction with an intraocular lens implant. Different studies have shown that a reduction in PCO frequency can be achieved via a number of factors. Lens design is a significant criterion in this process. In this study, two multifocal intraocular lenses (MIOLs) were compared. The design of these lenses differed due to their varying optical principles. They are the refractive MIOL A...

  20. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  1. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  2. Predictability of uncontrollable multifocal seizures - towards new treatment options

    Science.gov (United States)

    Lehnertz, Klaus; Dickten, Henning; Porz, Stephan; Helmstaedter, Christoph; Elger, Christian E.

    2016-04-01

    Drug-resistant, multifocal, non-resectable epilepsies are among the most difficult epileptic disorders to manage. An approach to control previously uncontrollable seizures in epilepsy patients would consist of identifying seizure precursors in critical brain areas combined with delivering a counteracting influence to prevent seizure generation. Predictability of seizures with acceptable levels of sensitivity and specificity, even in an ambulatory setting, has been repeatedly shown, however, in patients with a single seizure focus only. We did a study to assess feasibility of state-of-the-art, electroencephalogram-based seizure-prediction techniques in patients with uncontrollable multifocal seizures. We obtained significant predictive information about upcoming seizures in more than two thirds of patients. Unexpectedly, the emergence of seizure precursors was confined to non-affected brain areas. Our findings clearly indicate that epileptic networks, spanning lobes and hemispheres, underlie generation of seizures. Our proof-of-concept study is an important milestone towards new therapeutic strategies based on seizure-prediction techniques for clinical practice.

  3. Imaging manifestations of progressive multifocal leukoencephalopathy

    International Nuclear Information System (INIS)

    Shah, R.; Bag, A.K.; Chapman, P.R.; Cure, J.K.

    2010-01-01

    Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease caused by reactivation of JC virus in immunosuppressed patients. The diagnosis is usually suggested on imaging and confirmed by cerebrospinal fluid polymerase chain reaction (PCR) for JC virus DNA. In this article, we review the imaging manifestations of PML on computed tomography (CT), magnetic resonance imaging (MRI), diffusion-weighted imaging (DWI), diffusion tensor imaging (DTI), MR spectroscopy, single photon-emission computed tomography (SPECT) and positron-emission tomography (PET), and outline the role of imaging in follow-up and prognostication.

  4. Fundus autofluorescence patterns in primary intraocular lymphoma.

    Science.gov (United States)

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  5. Aderência in vitro do Staphylococcus epidermidis e da Pseudomonas alcaligenes em lentes intra-oculares In vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to intraocular lenses

    Directory of Open Access Journals (Sweden)

    Patrícia Ioschpe Gus

    2006-06-01

    Full Text Available OBJETIVO: Quantificar e comparar a aderência in vitro das bactérias Staphylococcus epidermidis e Pseudomonas alcaligenes em diferentes tipos de lentes intra-oculares (LIOs. MÉTODOS: Quatorze lentes intra-oculares foram usadas no experimento. Quatro de polimetilmetacrilato (PMMA, quatro de silicone, quatro de hidrogel e duas de acrílico. Oito lentes intra-oculares foram colocadas em oito tubos de ensaio contendo 4 ml de suspensão de Pseudomonas alcaligenes, e seis lentes intra-oculares foram colocadas em seis tubos de ensaio contendo 4 ml de suspensão de Staphylococcus epidermidis. A concentração do caldo utilizada para o teste de aderência foi de 10(8 unidades formadoras de colônias por mililitro (CFU/mL que corresponde a 0,5 na escala de McFarland. As lentes foram incubadas a 37° por duas horas. Após, foram removidas dos caldos e enxaguadas em água destilada estéril por duas vezes. As lentes foram cultivadas em placas de ágar-sangue a 35-37° e evaliadas a cada 24h por um período de 72h. Nas amostras que tiveram crescimento bacteriano, foram contadas as colônias utilizando os métodos convencionais de laboratório. Todos os ensaios foram executados em duplicata. RESULTADOS: A aderência do Staphylococcus epidermidis nas lentes de PMMA foi menor se comparada com as de silicone e de hidrogel. A aderência daPseudomonas alcaligenes nas lentes de hidrogel foi menor se comparada com as de silicone, PMMA e acrílico. CONCLUSÃO: Os resultados sugerem que a aderência do Staphylococcus epidermidis e da Pseudomonas alcaligenes nas lentes intra-oculares é influenciada pelo tipo de material da lente e pela espécie do microorganismo. A aderência bacteriana pode ter papel importante na patogenicidade da endoftalmite pós-cirurgia de catarata.PURPOSE: To quantify and compare the in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to different intraocular lenses (IOLs. METHODS: Fourteen intraocular lenses were

  6. WHAT HAPPENS TO INTRAOCULAR PRESSURE AFTER PERIBULBAR ANAESTHESIA?

    Directory of Open Access Journals (Sweden)

    Krishnamoorthy Segharipuram Ranganathan

    2017-08-01

    Full Text Available BACKGROUND Most of intraocular surgeries are done under local anaesthesia. The peribulbar anaesthesia provides adequate anaesthesia and akinesia. There is no reported intraoperative and/or postoperative amaurosis. The peribulbar anaesthesia provides adequate anaesthesia and akinesia. The disadvantages of it are the larger quantity of the aesthetic agent. Increasing the bulk load on the globe and a reported rise of intraocular pressure. MATERIALS AND METHODS A study of fifty cases was conducted in patients who received peribulbar anaesthesia undergoing cataract extraction with intraocular lens implantation and their intraocular pressures were noted and studied after giving the peribulbar anaesthesia all given by the same surgeon. RESULTS This study did show that the peribulbar anaesthesia increases the intraocular pressure in all the cases. The external ocular compression indeed helps to dissipate the anaesthetic load thereby reducing the enormous rise in IOP, which is only expected if you recollect the fact that the eyeball occupies one sixth of the total volume of the orbit that is 5 mL and 30 mL. The volume of peribulbar anaesthesia (6 mL does add its effects to increase the IOP. Hence, a properly planned post peribulbar compression helps to minimise the transient rise in IOP. CONCLUSION Summarising the study, it is better to give peribulbar injection initially followed by external ocular compression after a delay of at least 2 to 5 minutes. It is also advised that an initial compression maybe given in slightly risk cases, so that the peribulbarinduced rise may not be alarming. The anaesthetic solution maybe fragmented and the second injection maybe delayed by 5 minutes or omitted if good akinesia and anaesthesia are achieved already.

  7. Chest wall resection for multifocal osseous haemangioma.

    Science.gov (United States)

    Weinandt, Marthe; Legras, Antoine; Mordant, Pierre; Le Pimpec Barthes, Françoise

    2016-02-01

    Intraosseous haemangioma is a rare and benign primary tumour of the bone. We report the case of a 76-year old woman who presented the exceptional condition of multifocal cavernous haemangiomas involving the spine and the ribs, requiring spinal and chest wall resections to confirm the diagnosis and treat the symptoms. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. N-3 Polyunsaturated Fatty Acids of Marine Origin and Multifocality in Human Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Lobna Ouldamer

    Full Text Available The microenvironment of breast epithelial tissue may contribute to the clinical expression of breast cancer. Breast epithelial tissue, whether healthy or tumoral, is directly in contact with fat cells, which in turn could influence tumor multifocality. In this pilot study we investigated whether the fatty acid composition of breast adipose tissue differed according to breast cancer focality.Twenty-three consecutive women presenting with non-metastatic breast cancer underwent breast-imaging procedures including Magnetic Resonance Imaging prior to treatment. Breast adipose tissue specimens were collected during breast surgery. We established a biochemical profile of adipose tissue fatty acids by gas chromatography. We assessed whether there were differences according to breast cancer focality.We found that decreased levels in breast adipose tissue of docosahexaenoic and eicosapentaenoic acids, the two main polyunsaturated n-3 fatty acids of marine origin, were associated with multifocality.These differences in lipid content may contribute to mechanisms through which peritumoral adipose tissue fuels breast cancer multifocality.

  9. N-3 Polyunsaturated Fatty Acids of Marine Origin and Multifocality in Human Breast Cancer.

    Science.gov (United States)

    Ouldamer, Lobna; Goupille, Caroline; Vildé, Anne; Arbion, Flavie; Body, Gilles; Chevalier, Stephan; Cottier, Jean Philippe; Bougnoux, Philippe

    2016-01-01

    The microenvironment of breast epithelial tissue may contribute to the clinical expression of breast cancer. Breast epithelial tissue, whether healthy or tumoral, is directly in contact with fat cells, which in turn could influence tumor multifocality. In this pilot study we investigated whether the fatty acid composition of breast adipose tissue differed according to breast cancer focality. Twenty-three consecutive women presenting with non-metastatic breast cancer underwent breast-imaging procedures including Magnetic Resonance Imaging prior to treatment. Breast adipose tissue specimens were collected during breast surgery. We established a biochemical profile of adipose tissue fatty acids by gas chromatography. We assessed whether there were differences according to breast cancer focality. We found that decreased levels in breast adipose tissue of docosahexaenoic and eicosapentaenoic acids, the two main polyunsaturated n-3 fatty acids of marine origin, were associated with multifocality. These differences in lipid content may contribute to mechanisms through which peritumoral adipose tissue fuels breast cancer multifocality.

  10. Nonsyndromic Synchronous Multifocal Central Giant Cell Granulomas of the Maxillofacial Region: Report of a Case.

    Directory of Open Access Journals (Sweden)

    Anita Munde

    2015-04-01

    Full Text Available Central giant cell granuloma (CGCG is a benign proliferation of fibroblasts and multinucleated giant cells that almost exclusively occurs in the jaws. It commonly occurs in young adults showing a female predilection in the anterior mandible. Multifocal CGCGs in maxillofacial region are very rare and suggestive of systemic diseases such as hyperparathyroidism, an inherited syndrome such as Noonan-like multiple giant cell lesion syndrome or other disorders. Only 10 cases of multifocal CGCGs in the maxillofacial region without any concomitant systemic disease have been reported in the English literature. Here, we report an unusual case of 36 year-old female presented with non-syndromic synchronous, multifocal CGCGs in the left posterior mandible and left posterior maxilla without any concomitant systemic disease. Relevant literature is reviewed and the incidence, clinical features, radiological features, differential diagnosis and management of CGCGs are discussed.

  11. Visual outcome with the Oculentis Mplus intraocular lens

    OpenAIRE

    Si-Yuan Liu; Xu Yang

    2017-01-01

    AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL).METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOL)were as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At ...

  12. Towards customized intraocular lenses

    NARCIS (Netherlands)

    de Jong, Tim

    2017-01-01

    In the eye there are two refractive components that make light focus on the retina and let you see: the cornea and the lens. When a eye develops cataract the lens becomes caractarous and is removed and replaced with a synthetic intraocular lens during a cataract surgery procedure. Although there was

  13. Multifocal Synchronous Granular Cell Tumors of the Gastrointestinal Tract

    OpenAIRE

    Lipkin-Moore, Zachary; Thomas, Rebecca M.; Rothstein, Robin D.

    2014-01-01

    Granular cell tumors (GCT) are rare and unusual tumors, which are usually benign and asymptomatic. Only 5?10% of cases involve the gastrointestinal tract, most commonly as singular, non-cancerous lesions in the esophagus. We report a rare case of symptomatic, multifocal, synchronous GCT involving the esophagus, stomach, and cecum.

  14. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

  15. Clinical study on the incidence of vancomycin intraocular injection in treatment with suppurative endophthalmitis

    Directory of Open Access Journals (Sweden)

    Yi-Qin Duan

    2015-05-01

    Full Text Available AIM:To estimate the clinical significance of the microculture of humor and vitreous and vancomycin intraocular injection in treatment of suppurative endophthalmitis associated with intraocular foreign bodies.METHODS: Totally 65 patients with penetrating eye trauma and retained intraocular foreign bodies in emergency operation and intraocular injection from January 2012 to September 2014 were regarded as the study group, another 62 patients with penetrating eye trauma and retained intraocular foreign bodies in emergency operation without intraocular injection before August 2011 were regarded as the control group. Aqueous humor and vitreous humor were taken from each patient of the study group and the control group for bacteria and fungus cultivation. The study group was treated with 1mg vancomycin intraocular injection after operation, while the control group was not. RESULTS: The incidence of endophthalmitis in the control group was 16%(10 cases, while in the study group was 3%(2 cases, with significant difference between two groups(x2=6.32, PP>0.05. The positive rate of vitreous humor germiculture in study group was 14%(9 cases, and the incidence of endophthalmitis was 3%. The positive rate of vitreous humor germiculture in control group was 11%(7 casesand the incidence of endophthalmitis was 16%, with significant differences between two groups(PCONCLUSION: Intraocular foreign bodies treated with emergency operation and vancomycin intraocular injections can decrease the incidence of suppurative endophthalmitis and have a good vision prognosis for the second stage of operation.

  16. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China.

    Directory of Open Access Journals (Sweden)

    Bingsheng Lou

    Full Text Available To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury.A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014.A total of 153 (30.6% of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9% and intravitreal injection (42.0%. Cephalosporins (53.8% and vancomycin (42.0% were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%, and aminoglycosides (13.4%. Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7% replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4% (p = 0.001, Fisher's exact test.Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis.

  17. Mean intraocular pressure in hypertensive adults

    International Nuclear Information System (INIS)

    Irum, S.; Malik, A.M.; Saeed, M.

    2015-01-01

    To determine the mean Intraocular Pressure (IOP) in already diagnosed adult hypertensive patients with different grades of hypertension. Study Design: Cross-sectional descriptive study. Place and Duration of Study: Combined Military Hospital, Lahore, from March 2012 to Aug 2012. Patients and Methods: A total of 178 already diagnosed hypertensive patients were selected. A detailed history of ocular or systemic diseases was taken. Intraocular pressure was measured with help of Goldmann applanation tonometer. Three consecutive readings of IOP of each eye were taken at 30 minutes interval and mean calculated. Blood pressure was recorded in seated position from right upper arm, by mercury sphygmomanometer. Blood pressure measurements were determined by taking the mean value of three systolic and diastolic readings. Results: The results of intraocular pressure (IOP) between various grades of hypertension were determined. There was an increase in mean IOP with rise in blood pressure. The subjects with grade I hypertension showed a mean IOP of 13.95 ± 3.74 mmHg, while grade II and grade III hypertensive subjects had mean IOPs as 18.10 ± 3.32 and 20.21 ± 2.52 mmHg respectively. Conclusion: A higher value of mean IOP was found with increase in systolic and diastolic blood pressures. (author)

  18. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  19. The multifocal electroretinogram (mfERG) in the pig

    DEFF Research Database (Denmark)

    Voss Kyhn, Maria; Kiilgaard, Jens Folke; Lopez, Ana Garcia

    2007-01-01

    To establish a method allowing multifocal electroretinography (mfERG) recording with simultaneous fundus monitoring on anaesthetized pigs. In addition we characterize the peaks of the porcine mfERG trace, and compare the visual streak area with the optic nerve head, a known non-response area....... Finally we illustrate the feasibility of the method by performing mfERG after an induced laser burn in the visual streak....

  20. A case of osseous scintigraphy showing focuses of multifocal tuberculosis

    International Nuclear Information System (INIS)

    Faurous-Vanaud, R.; Faurous, P.; Kalfa, G.; Collet, H.; Couty, H.; Artus, J.C.

    1997-01-01

    Incidence of tuberculosis in developed countries presents in the last years a spectacular boost. However, the osteo-articular system is afflicted by tuberculosis only in a few percent of cases and the multifocal character represents less than 5% of osseous tuberculosis. It is presented here a case of multifocal osseous tuberculosis only to stress its rarity. A woman 28 years old from Djibouti presents since 8 months an asthenia and dorsal pains long thought as psychalgia. The examination has shown a major vertebral stiffness and limitation of right haunch. The radiographs showed a scoliosis centered on D8 with modifications. The biologic data are VS = 90, CRP = 124 and the hemogram is normal. The intradermal reaction (10 U of tuberculin) is phlyctenular. The TDM indicates lytic vertebral extension on D7 - D8, the osseous scintigraphy with MDP - 99 mTc indicates no anomaly in the vascular arrival time; a few minutes after injection: dorsal and upper and of right femur hyperactivity; 2 h after injection: hyper-fixation of D7 to D9 and of the upper end of right femur. The IRM indicates para-vertebral abscess of D7 to D9 with epidural abscess; abscess in the upper part of the loge of right adductors with osseous affliction of the femur's upper end; a bacillary infectious process was a priori evoked. The patient was then placed under quadruple antibiotic-therapy anti-tuberculous care. In case of anomalous multifocal osseous scintigraphy the tuberculous affliction is part of the differential diagnosis, particularly in the immigrant populations or in HIV+ persons

  1. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  2. Topical tissue plasminogen activator appears ineffective for the clearance of intraocular fibrin.

    Science.gov (United States)

    Zwaan, J; Latimer, W B

    1998-06-01

    To determine the efficacy of topical tissue plasminogen activator (tPA) for the resolution of postoperative or inflammatory intraocular fibrinous exudates. Each treatment consisted of drops of 1 mg/ml tPA given 9 times 5 minutes apart. Records were reviewed and the results at 24 and 48 hours were recorded. Sixty-two patients had a total of 94 treatments. Fibrin exudates following intraocular surgery in 34 patients were treated 44 times. In 6 patients there was a positive result. Fibrin associated with intraocular infection was treated in 9 patients. None showed clear improvement. Nineteen patients had a total of 34 treatments for poorly controlled intraocular pressure (IOP) after glaucoma surgery. Five patients showed adequate control of the IOP, 12 did not change, and 2 had a questionable improvement. Eleven patients had adequate IOP control after additional treatment. Seven required suture lysis, 2 ab interno bleb revision, and 2 YAG capsulotomy or iridotomy to reduce the IOP to an acceptable level. Within the limits of this retrospective study and taking into account that fibrin may resolve spontaneously, it appears that topical tPA drops are not effective for the liquefaction of intraocular fibrin after surgery or in association with intraocular inflammation. They did not improve IOP control after glaucoma surgery.

  3. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  4. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant

    Directory of Open Access Journals (Sweden)

    Clara Ye

    2018-06-01

    Full Text Available Purpose: We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL (Visian ICL™, Staar Inc., Monrovia, CA implant that resulted in advanced visual field loss. Observations: A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Conclusions and importance: Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss. Keywords: Phakic intraocular lens, Intraocular collamer lens, Pigment dispersion, Glaucoma

  5. Chronic multifocal non-bacterial osteomyelitis in hypophosphatasia mimicking malignancy

    Directory of Open Access Journals (Sweden)

    Warmuth-Metz Monika

    2007-01-01

    Full Text Available Abstract Background Hypophosphatasia (HP is characterized by a genetic defect in the tissue-nonspecific alkaline phosphatase (TNSALP gene and predominantly an autosomal recessive trait. HP patients suffer from reduced bone mineralization. Biochemically, elevated concentrations of substrates of TNSALP, including pyridoxal-5'-phosphate and inorganic pyrophosphate occur in serum, tissues and urine. The latter has been associated with chronic inflammation and hyperprostaglandinism. Case presentation We report on 2 affected children presenting with multifocal inflammatory bone lesions mimicking malignancy: A 6 years old girl with short stature had been treated with human growth hormone since 6 months. Then she started to complain about a painful swelling of her left cheek. MRI suggested a malignant bone lesion. Bone biopsy, however, revealed chronic inflammation. A bone scan showed a second rib lesion. Since biopsy was sterile, the descriptive diagnosis of chronic non-bacterial osteomyelitis (CNO was established. The diagnostic tests related to growth failure were repeated and subsequent analyses demonstrated a molecular defect in the TNSALP gene. The second girl (10 years old complained about back pain after she had fallen from her bike. X rays of her spine revealed compressions of 2 thoracic vertebrae. At first these were considered trauma related, however a bone scan did show an additional lesion in the right 4th rib. A biopsy of this rib revealed a sterile lympho- plasmocytoid osteomyelitis suggesting multifocal CNO. Further analyses did show a decreased TNSALP in leukocytes and elevated pyridoxal phosphate in plasma, suggesting a heterozygous carrier status of HP. Conclusion Chronic bone oedema in adult HP and chronic hyper-prostaglandinism in childhood HP do suggest that in some HP patients bone inflammation is present in conjunction with the metabolic defect. Sterile multifocal osteomyelitis could be demonstrated. Non-steroidal anti

  6. Transferring diffractive optics from research to commercial applications: Part II - size estimations for selected markets

    Science.gov (United States)

    Brunner, Robert

    2014-04-01

    In a series of two contributions, decisive business-related aspects of the current process status to transfer research results on diffractive optical elements (DOEs) into commercial solutions are discussed. In part I, the focus was on the patent landscape. Here, in part II, market estimations concerning DOEs for selected applications are presented, comprising classical spectroscopic gratings, security features on banknotes, DOEs for high-end applications, e.g., for the semiconductor manufacturing market and diffractive intra-ocular lenses. The derived market sizes are referred to the optical elements, itself, rather than to the enabled instruments. The estimated market volumes are mainly addressed to scientifically and technologically oriented optical engineers to serve as a rough classification of the commercial dimensions of DOEs in the different market segments and do not claim to be exhaustive.

  7. Assessment of intraocular foreign bodies by helical-CT multiplanar imaging

    International Nuclear Information System (INIS)

    Papadopoulos, A.; Fotinos, A.; Maniatis, V.; Kavadias, S.; Michaelides, A.; Avouri, M.; Kalamara, C.; Stringaris, K.

    2001-01-01

    The aim of this study was to examine the effectiveness of helical CT in the assessment of intraocular foreign bodies, evaluating two protocols with different collimation. We performed helical-CT studies in 30 patients. Fifteen patients were examined with 1.5-mm collimation and the other 15 patients with 3.0-mm collimation. All other imaging parameters were identical in both protocols. Multiplanar images were reconstructed. The examinations were reviewed for presence, localization and size of intraocular foreign bodies. We compare our results with the surgical data. We estimate the required examination time. In the first group (collimation 1.5 mm) an intraorbital foreign body was detected in 8 of 15 patients. In 3 of 8 patients an intraocular foreign body (all were metallic) was detected. In the second group (collimation 3.0 mm) an intraorbital foreign body was detected in 9 of 15 patients. In 8 of 9 patients an intraocular foreign body (all were metallic) was detected. Our results were confirmed by surgery in all cases. Examination time was 36 s in the first group and 18 s in the second group. Computed tomography should be considered the imaging modality of choice in the assessment of metallic intraocular foreign bodies and 3.0-mm collimation is optional, because of reduced examination time and radiation exposure. (orig.)

  8. A novel clinical sign in intraocular tuberculosis: Active chorioretinitis within chorioretinal atrophy

    OpenAIRE

    Avinash Pathengay; Bhavik Panchal; Himadri Choudhury; Soumyava Basu; Nidhi Relhan; Harry W. Flynn, Jr.

    2017-01-01

    Purpose: To report a novel clinical sign in patients with intraocular tuberculosis. The current study is an observational consecutive case series of patients diagnosed with intraocular tuberculosis managed at a tertiary eye care centre from June 1, 2012 to December 31, 2015. Observations: The diagnosis of intraocular tuberculosis was made in 6 patients based on ocular features suggestive of tuberculosis along with a positive tuberculin skin testing and chest X-ray consistent with tuberculo...

  9. Case report: multifocal subchondral stress fractures of the femoral heads and tibial condyles in a young military recruit.

    Science.gov (United States)

    Yoon, Pil Whan; Yoo, Jeong Joon; Yoon, Kang Sup; Kim, Hee Joong

    2012-03-01

    Subchondral stress fractures of the femoral head may be either of the insufficiency-type with poor quality bone or the fatigue-type with normal quality bone but subject to high repetitive stresses. Unlike osteonecrosis, multiple site involvement rarely has been reported for subchondral stress fractures. We describe a case of multifocal subchondral stress fractures involving femoral heads and medial tibial condyles bilaterally within 2 weeks. A 27-year-old military recruit began having left knee pain after 2 weeks of basic training, without any injury. Subsequently, right knee, right hip, and left hip pain developed sequentially within 2 weeks. The diagnosis of multifocal subchondral stress fracture was confirmed by plain radiographs and MR images. Nonoperative treatment of the subchondral stress fractures of both medial tibial condyles and the left uncollapsed femoral head resulted in resolution of symptoms. The collapsed right femoral head was treated with a fibular strut allograft to restore congruity and healed without further collapse. There has been one case report in which an insufficiency-type subchondral stress fracture of the femoral head and medial femoral condyle occurred within a 2-year interval. Because the incidence of bilateral subchondral stress fractures of the femoral head is low and multifocal involvement has not been reported, multifocal subchondral stress fractures can be confused with multifocal osteonecrosis. Our case shows that subchondral stress fractures can occur in multiple sites almost simultaneously.

  10. Progressive multifocal leukoencephalopathy: new concepts

    Directory of Open Access Journals (Sweden)

    Marco A. Lima

    2013-09-01

    Full Text Available Progressive multifocal leukoencephalopathy (PML is a demyelinating disease of the CNS caused by reactivation of JC virus (JCV in a setting of cellular immunosuppression. Originally, PML was observed in patients with advanced HIV infection, lymphoproliferative disorders and transplant recipients. However, the widespread use of HIV antiretroviral drugs and the new selective immunomodulatory and immunosuppressive medications, such as Rituximab and Natalizumab, has recently modified the epidemiology, clinical presentation and prognosis of PML. Herein, we discuss the new concepts on PML, emphasizing the recent modification in the epidemiology; the impact of new immunomodulatory treatments in the disease, PML-IRIS (Immune reconstitution inflammatory síndrome, new treatment strategies and other JCV related CNS diseases.

  11. Fatores técnicos intervenientes na realização do exame de eletrorretinograma multifocal (ERGmf Technical factors that influence multifocal electroretinogram (mfERG recording

    Directory of Open Access Journals (Sweden)

    Maria Kiyoko Oyamada

    2007-08-01

    Full Text Available OBJETIVO: Descrever os principais fatores intervenientes observados durante a aquisição e análise do exame de eletrorretinograma multifocal (ERGmf, que afetam o registro gráfico das ondas obtidas e portanto sua análise. MÉTODOS: Análise dos fatores de erro observados durante a aquisição de 100 exames seqüenciais de eletrorretinograma multifocal, realizados com o Reti System da Roland Consult, no período de maio a julho de 2005. Os exames de eletrorretinograma multifocal foram realizados conforme recomendações internacionais, respeitando-se os parâmetros preestabelecidos do equipamento, com 61 elementos, e ângulo visual de 30º. Todos os pacientes foram submetidos à avaliação oftalmológica completa, excluindo-se aqueles com transparência inadequada de meios, córneas planas e os incapazes de visualizar as linhas de fixação. RESULTADOS: Os fatores intervenientes, que poderiam causar erros na interpretação dos resultados obtidos, observados e corrigidos durante a realização dos exames foram: fixação excêntrica, movimentação dos olhos, contração do orbicular, contração da musculatura cervical, não-correção adequada, não-transparência adequada do eletrodo corneano, deslocamento do eletrodo em geral para baixo, descentralização do suporte da lente corretora, distância inadequada paciente-monitor em pacientes com alta ametropia, altura inadequada dos olhos em relação ao centro da tela, ruído na freqüência de 60 HZ (rede elétrica e de campo eletromagnético, impedâncias elevadas. No processamento das ondas, a utilização excessiva de filtros para remoção de ruídos dos registros obtidos, pode interferir na análise dos resultados obtidos. CONCLUSÕES: Cuidados simplesmente observacionais durante a aquisição dos sinais são de importância significativa para a obtenção de registros com boa morfologia e baixo nível de ruído. Permitindo, por meio de sua pronta correção, a análise correta e

  12. Unusual multifocal granulomatous disease caused by actinomycetous bacteria in a nestling Derbyan parrot (Psittacula derbiana).

    Science.gov (United States)

    Park, F J; Jaensch, S

    2009-01-01

    A nestling Derbyan parrot (Psittacula derbiana) was presented with unusual subcutaneous swellings of the thigh regions, and poor growth. Histological examination revealed actinomycetous bacteria associated with multifocal systemic granulomas. The clinical and pathological findings of the case are presented, and some relevant aspects of actinomycetous bacterial infections in mammals and birds are discussed. Although granulomatous disease is encountered at times in avian species, the actinomycetous bacteria (Nocardia and Actinomyces spp.) have rarely been reported in association with multifocal granulomatous disease in birds.

  13. The Mathematical Theory of Multifocal Lenses

    Institute of Scientific and Technical Information of China (English)

    Jacob RUBINSTEIN

    2017-01-01

    This paper presents the fundamental optical concepts of designing multifocal ophthalmic lenses and the mathematical methods associated with them.In particular,it is shown that the design methodology is heavily based on differential geometric ideas such as Willmore surfaces.A key role is played by Hamilton's eikonal functions.It is shown that these functions capture all the information on the local blur and distortion created by the lenses.Along the way,formulas for computing the eikonal functions are derived.Finally,the author lists a few intriguing mathematical problems and novel concepts in optics as future projects.

  14. Renal Function Outcomes for Multifocal Renal Neoplasms Managed by Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Pushpender, E-mail: pugupta@wakehealth.edu; Allen, Brian C., E-mail: bcallen2@wakehealth.edu; Chen, Michael Y., E-mail: mchen@wakehealth.edu; Childs, David D., E-mail: dchilds@wakehealth.edu; Kota, Gopi, E-mail: gkota@wakehealth.edu; Zagoria, Ronald J., E-mail: rzagoria@wakehealth.edu [Wake Forest University School of Medicine, Department of Radiology (United States)

    2013-10-15

    Purpose: To evaluate renal function changes related to radiofrequency ablation (RFA) for the treatment of multifocal renal neoplasms. Methods: This is an institutional review board-approved, Health Insurance Portability and Accountability Act compliant retrospective study of all patients treated with computed tomography guided RFA for multifocal renal neoplasms at one institution. Fifty-seven subjects, mean age 70 (range 37-88) years, underwent RFA of 169 renal neoplasms (average size 2.0 cm). Subjects had between 2 and 8 (mean 2.96) neoplasms ablated. Estimated glomerular filtration rate (eGFR) was measured before and after RFA. Complications related to RFA were recorded. Results: eGFR decreased on average of 4.4 % per tumor treated and 6.7 % per ablation session (average 1.76 tumors treated per session). For subjects with the largest neoplasm measuring >3 cm, eGFR decreased an average of 14.5 % during the course of their treatment. If the largest neoplasm measured 2-3 cm, eGFR decreased an average of 7.7 %, and if the largest neoplasm measured <2 cm, eGFR decreased an average of 3.8 %. Subjects with reduced baseline renal function were more likely to have a greater decline in eGFR after RFA. There was a minor complication rate of 6.3 % (6 of 96 sessions), none of which required treatment, and a major complication rate of 4.2 % (4 of 96 sessions). Conclusion: RFA for the treatment of multifocal renal neoplasms results in mild decline of renal function.

  15. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  16. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens.

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. The mean follow-up was 23 months (range: 6-48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context of a surgery usually indicated in

  17. Effect of Unifocal versus Multifocal Lenses on Cervical Spine Posture in Patients with Presbyopia.

    Science.gov (United States)

    Abbas, Rami L; Houri, Mohamad T; Rayyan, Mohammad M; Hamada, Hamada Ahmad; Saab, Ibtissam M

    2018-04-04

    There are many environmental considerations which may or may not lead to the development of faulty cervical mechanics. The design of near vision lenses could contribute to the development of such cervical dysfunction and consequently neck pain. Decision making regarding proper type of lens prescription seems important for presbyopic individuals. To investigate the effect of unifocal and multifocal lenses on cervical posture. Thirty subjects (18 females and 12 males) participated in the study with an age range from 40 to 64 years. Each subject wore consequently both unifocal and multifocal lenses randomly while reading. Then lateral cervical spine X-ray films were taken for each subject during each lens wearing. X-ray films were analyzed with digital software (Autocad software, 2 D) to measure segmental angles of the cervical vertebrae (Occiput/C1, C1/C2, C2/C3, C3/C4, C4/C5, C5/C6, C6/C7, C3/C7, C0/C3, and occiput/C7). Higher significant extension angle in the segments C0/C7, C1/C2, C5/C6, C6/C7, and C3/C7 (p<0.05) during multifocal lenses wearing were observed in contrast with higher flexion angle between C3/C4 and C4/C5 (p<0.05) with unifocal lenses wear. Multifocal lens spectacles produces increased extension in the cervical vertebrae angles when compared with the use of unifocal lenses.

  18. Premature epiphyseal fusion and degenerative arthritis in chronic recurrent multifocal osteomyelitis

    International Nuclear Information System (INIS)

    Piddo, C.; Reed, M.H.; Black, G.B.

    2000-01-01

    A 9-year-old boy was diagnosed with chronic recurrent multifocal osteomyelitis affecting multiple sites. During an 8-year follow-up he developed premature closure of a distal radial epiphysis and degenerative changes in the adjacent radiocarpal joint. (orig.)

  19. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

    Directory of Open Access Journals (Sweden)

    Aditya Kelkar

    2015-07-01

    Full Text Available Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  20. Multifocal gastrointestinal stromal tumor (GIST) of the stomach in an 11-year-old girl

    International Nuclear Information System (INIS)

    Park, Jin; Rubinas, Tara C.; Fordham, Lynn A.; Phillips, J.D.

    2006-01-01

    A previously healthy 11-year-old girl presented with an 8-month history of anemia and left upper quadrant abdominal pain. US examination demonstrated a 9-cm cystic mass with a fluid-fluid level in the left upper quadrant with unclear organ of origin. Abdominal MR imaging demonstrated a complex cystic mass, likely arising from the stomach. Additional T2 hyperintense submucosal lesions were identified in the gastric wall. Surgical excision confirmed the diagnosis of multifocal gastric gastrointestinal stromal tumor (GIST). MR imaging was helpful in suggesting a gastric origin of the primary mass and in demonstrating multifocal disease within the stomach. (orig.)

  1. Flurbiprofen and intraocular pressure.

    Science.gov (United States)

    Gieser, D K; Hodapp, E; Goldberg, I; Kass, M A; Becker, B

    1981-07-01

    Systemic or topical administration of corticosteroids may produce a rise in intraocular pressure (IOP). Nonsteroidal anti-inflammatory drugs (NSAI drugs) are alternate therapy for ocular inflammatory disease. Flurbiprofen, a new NSAI drug, was tested in double-masked fashion to delineate its effect on IOP. Flurbiprofen did not alter IOP in known high corticosteroid responders nor did it block corticosteroid-induced ocular hypertension.

  2. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  3. Experiencia con la lente intraocular RAYNER 620H Experience gained with the use of intraocular lens RAYNER 620 H

    Directory of Open Access Journals (Sweden)

    Juan Raúl Hernández Silva

    2008-06-01

    Full Text Available Un importante eslabón en el progreso alcanzado en la cirugía de cataratas, está fundamentado en el desarrollo industrial paralelo que ha ocurrido durante los últimos años con la introducción de nuevos modelos de lentes intraoculares, como el Rayner 620 H; el perfeccionamiento del instrumental quirúrgico, sistemas de aspiración e irrigación bimanual y bisturí con la medida exacta para colocar el inyector de la lente intraocular. La lente intraocular Rayner 620H significó un gran paso para la facoemulsificación y el control de la opacidad de la cápsula posterior posoperatoria por el diseño peculiar de su óptica y hápticos, que permiten un implante seguro, fácil y una incisión mínima. Se realizó un estudio prospectivo y descriptivo, cuyo universo de estudio fueron 28 ojos con diagnóstico de cataratas a los cuales se les realizó facoemulsificación con implante de lente intraocular Rayner 620 H, en el Centro de Microcirugía Ocular del Instituto Cubano de oftalmología "Ramón Pando Ferrer" en el período comprendido entre junio de 2006 a febrero de 2007. El grupo de edades donde se encontró el de mayor número de pacientes fue en el de más de 60 años. En todos los casos hubo un aumento significativo de la agudeza visual sin corrección y con ella, del preoperatorio al posoperatorio. Hubo un aumento del cilindro queratométrico del preoperatorio al posoperatorio, pero este fue mínimo La pérdida de células endoteliales fue baja del preoperatorio al posoperatorio, respectivamente. No hubo ninguna complicación durante la cirugía ni después de esta. Evaluamos como satisfactoria la efectividad del lente intraocular Rayner 620 H, por el aumento de la agudeza visual del paciente, el bajo astigmatismo inducido, mejoría del campo visual por confrontación, mínima pérdida de células endoteliales, y ausencia de complicaciones y de deslumbramiento posoperatorio en los pacientes.An important link in the advances made by the

  4. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  5. Intraocular manifestations of mycobacterium tuberculosis: A review of the literature

    Directory of Open Access Journals (Sweden)

    Lauren A. Dalvin

    2017-05-01

    Full Text Available Mycobacterium tuberculosis: is most commonly associated with pulmonary infection. However, tuberculosis (TB can also affect the eye. TB can affect nearly any tissue in the eye, and a high index of suspicion is required for accurate diagnosis, as many of the intraocular manifestations of TB can mimic other, more common diseases. Correct diagnosis is critical because systemic anti-tuberculosis treatment may be required, and vision loss or even loss of the affected eye can occur without proper treatment. Thus, it is important for ophthalmologists and infectious disease specialists to work together to accurately diagnose and treat intraocular TB. This article reports the various known presentations of intraocular TB and reviews important elements of diagnosis and treatment. Keywords: Mycobacterium, Tuberculosis, Choroidal granuloma, Retinal vasculitis

  6. Epithelial Downgrowth after Intraocular Surgery Treated with Intracameral 5-Fluorouracil

    Directory of Open Access Journals (Sweden)

    Nina Ni

    2015-01-01

    Full Text Available Purpose. To present the clinical and histopathologic correlation of two cases of epithelial downgrowth (EDG after prior intraocular surgery. Methods. Observational case reports. Results. We present two cases of EDG occurring after intraocular surgery. In both cases, after two anterior chamber injections of 5-fluorouracil (5FU, the area of EDG initially regressed. In Case 1, a limited area of EDG eventually recurred, and penetrating keratoplasty with cryotherapy was curative. In Case 2, subsequent corneal edema required Descemet-stripping automated endothelial keratoplasty, and the patient remained clinically free of EDG without further treatment. Conclusion. Intracameral 5FU may have a role in the treatment of EDG after intraocular surgery, though its precise utilization and impact remain to be defined.

  7. Multifocal fibrosing thyroiditis: report of 55 cases of a poorly recognized entity.

    Science.gov (United States)

    Fellegara, Giovanni; Rosai, Juan

    2015-03-01

    During the course of our consultation activity, we have recognized a peculiar form of thyroiditis in which multiple foci of fibrosis, most of which were associated with reactive atypia of the surrounding follicles, are present. We have referred to this condition, both in our consultation reports and in the third series of A.F.I.P. Fascicle on Tumors of the Thyroid Gland, as "multifocal fibrosing thyroiditis" or (less frequently) "multifocal sclerosing thyroiditis," which are descriptive terms that highlight the benign/inflammatory nature of the process, its multiplicity, and its unknown pathogenesis. The aim of this study is to better define the morphologic features of this process and correlate it with some clinical data. With this purpose, the consultation files of one of the authors (J.R.) were searched for cases coded as multifocal fibrosing thyroiditis or multifocal sclerosing thyroiditis in a 20-year period ranging from January 1989 to December 2009. A total of 55 cases were identified that displayed the above-listed features. There were 51 (93%) female and 4 (7%) male patients (F/M=12.75), with ages ranging between 15 and 71 years (mean age, 47.03 y; median age, 44.5 y). Microscopically, multiple foci of fibrosis were identified in all cases, their number ranging from 2 to 51 per case (mean number, 16), with a mean diameter of 3 mm (range: 0.36 to 15.1 mm). Although heterogenous in shape and size, the individual foci were rather similar to each other in composition, being characterized by a fibrotic poorly cellular center that merged with a cellular peripheral zone. Some of the follicular structures present at the periphery of the scar and-to a lesser extent-those entrapped inside it underwent complex reactive and regenerative (atypical) changes that simulated malignancy. We discuss the differential diagnosis with other benign and malignant thyroid conditions and speculate about its pathogenesis and possible relationship with papillary thyroid microcarcinoma.

  8. Comparison between intraocular pressure spikes with water loading and postural change.

    Science.gov (United States)

    Chong, Calum Wk; Wang, Sarah B; Jain, Neeranjali S; Bank, Cassandra S; Singh, Ravjit; Bank, Allan; Francis, Ian C; Agar, Ashish

    2016-12-01

    To compare the agreement between peak intraocular pressures measured through the water drinking test and the supine test, in patients with primary open angle glaucoma. Consecutive, prospective, blinded. Twenty-one patients from the Glaucoma Unit, Prince of Wales Hospital, Sydney, Australia. For the supine test, intraocular pressure was recorded immediately after the patient had lain down and at 20 and 40 min. At the second evaluation, intraocular pressure was measured in each patient after drinking 10 mL/kg body weight of water for the water drinking test. Again, all patients had their intraocular pressure measured at 20 and 40 min (t = 20 and t = 40, respectively). Patients were excluded from the study if they had pre-existing cardiac, renal or pulmonary complications or had concurrent ocular disease or an anatomical abnormality (including angle recession, peripheral anterior synechiae and developmental anomalies of the angle) that may have influenced intraocular pressure. Bland-Altman analysis. Bland-Altman analysis indicated an overall excellent agreement in terms of mean difference between methods (1.0, -1.0 and -0.90 mmHg, at 0, 20 and 40 min, respectively). Further, with the exception of t = 40, all measured time points had 95% confidence intervals within 6.5 mmHg of their mean difference on the Bland-Altman plot. There was close agreement between the intraocular pressure values of the supine test and water drinking test. However, as the water drinking test may be uncomfortable and potentially hazardous, there is potential that the supine test may be a safer and more comfortable alternative. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  9. Exploring the methods of data analysis in multifocal visual evoked potentials

    DEFF Research Database (Denmark)

    Malmqvist, Lasse; Santiago de Abreu, Lucimar; Fraser, C.

    2016-01-01

    Purpose: The multifocal visual evoked potential (mfVEP) provides a topographical assessment of visual function, which has already shown potential for use in patients with glaucoma and multiple sclerosis. However, the variability in mfVEP measurements has limited its broader application. The purpo...

  10. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    Directory of Open Access Journals (Sweden)

    Korenfeld MS

    2016-01-01

    Full Text Available Michael S Korenfeld,1,2 David K Dueker3 1Comprehensive Eye Care, Ltd., 2Department of Ophthalmology and Visual Sciences, Washington University, Washington, MO, USA; 3Hamad Medical Corporation, Doha, Qatar Purpose: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods: A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results: The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion: This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. Keywords: glaucoma, intraocular pressure, tonometer, ocular compression

  11. Pigment dispersion and chronic intraocular pressure elevation after sulcus placement of 3-piece acrylic intraocular lens.

    Science.gov (United States)

    Almond, M Camille; Wu, Michael C; Chen, Philip P

    2009-12-01

    A 55-year-old man had phacoemulsification and implantation of a 3-piece acrylic intraocular lens (IOL) (AcrySof MA60AC) in the right eye. One month postoperatively, the intraocular pressure (IOP) was 48 mm Hg and peripheral transillumination defects were noted in the iris circumferentially, with the IOL optic edge visible as a silhouette. Gonioscopy showed dense pigmentation of the trabecular meshwork in the right eye, but in the left eye, only mild trabecular meshwork pigment was seen, along with a concave peripheral iris insertion. At 21 months, the right eye required 3 medications for IOP control. While pigment dispersion has been widely reported after placement of 1-piece acrylic IOLs in the ciliary sulcus, we conclude that in susceptible individuals with a concave peripheral iris insertion, pigment dispersion can occur with sulcus placement of a 3-piece acrylic model despite its thinner optic and angulated haptics.

  12. Upper Extremity Multifocal Neuropathy in a 10-Year-Old Boy Associated With NS6S Disaccharide Antibodies.

    Science.gov (United States)

    Edelman, Frederick; Naddaf, Elie; Waclawik, Andrew J

    2015-06-01

    We present a 10-year-old boy with a predominantly motor multifocal neuropathy with demyelinating and axonal changes with sensory involvement, affecting only one upper extremity. Laboratory studies revealed an elevated titer of immunoglobulin M (IgM) antibodies against the NS6S antigen. He responded to treatment with high dose intravenous immunoglobulins. Focal or multifocal immune-mediated neuropathies are not common in children and may be underdiagnosed. © The Author(s) 2014.

  13. Posterior Segment Intraocular Foreign Body: Extraction Surgical Techniques, Timing, and Indications for Vitrectomy

    Directory of Open Access Journals (Sweden)

    Dante A. Guevara-Villarreal

    2016-01-01

    Full Text Available Ocular penetrating injury with Intraocular Foreign Body (IOFB is a common form of ocular injury. Several techniques to remove IOFB have been reported by different authors. The aim of this publication is to review different timing and surgical techniques related to the extraction of IOFB. Material and Methods. A PubMed search on “Extraction of Intraocular Foreign Body,” “Timing for Surgery Intraocular Foreign Body,” and “Surgical Technique Intraocular Foreign Body” was made. Results. Potential advantages of immediate and delayed IOFB removal have been reported with different results. Several techniques to remove IOFB have been reported by different authors with good results. Conclusion. The most important factor at the time to perform IOFB extraction is the experience of the surgeon.

  14. Bacillus cereus panophthalmitis associated with intraocular gas bubble.

    Science.gov (United States)

    al-Hemidan, A; Byrne-Rhodes, K A; Tabbara, K F

    1989-01-01

    It has become increasingly apparent that Bacillus cereus can cause a severe and devastating form of endophthalmitis following penetrating trauma by a metallic object. B. cereus is an uncommon aetiological agent in non-clostridial gas-forming infections. The patient studied in this single case report showed evidence of intraocular gas mimicking gas gangrene infection. The physiology of non-clostridial bacteria producing gas from anaerobic metabolic conditions is reviewed. Further intraocular and systemic complications which may be avoided by accurate and early diagnosis and the use of recommended treatment with antibiotics such as clindamycin. Images PMID:2493262

  15. Influence of macular pigment optical density spatial distribution on intraocular scatter.

    Science.gov (United States)

    Putnam, Christopher M; Bland, Pauline J; Bassi, Carl J

    This study evaluated the summed measures of macular pigment optical density (MPOD) spatial distribution and their effects on intraocular scatter using a commercially available device (C-Quant, Oculus, USA). A customized heterochromatic flicker photometer (cHFP) device was used to measure MPOD spatial distribution across the central 16° using a 1° stimulus. MPOD was calculated as a discrete measure and summed measures across the central 1°, 3.3°, 10° and 16° diameters. Intraocular scatter was determined as a mean of 5 trials in which reliability and repeatability measures were met using the C-Quant. MPOD spatial distribution maps were constructed and the effects of both discrete and summed values on intraocular scatter were examined. Spatial mapping identified mean values for discrete MPOD [0.32 (s.d.=0.08)], MPOD summed across central 1° [0.37 (s.d.=0.11)], MPOD summed across central 3.3° [0.85 (s.d.=0.20)], MPOD summed across central 10° [1.60 (s.d.=0.35)] and MPOD summed across central 16° [1.78 (s.d.=0.39)]. Mean intraocular scatter was 0.83 (s.d.=0.16) log units. While there were consistent trends for an inverse relationship between MPOD and scatter, these relationships were not statistically significant. Correlations between the highest and lowest quartiles of MPOD within the central 1° were near significance. While there was an overall trend of decreased intraocular forward scatter with increased MPOD consistent with selective short wavelength visible light attenuation, neither discrete nor summed values of MPOD significantly influence intraocular scatter as measured by the C-Quant device. Published by Elsevier España, S.L.U.

  16. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  17. The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer

    Directory of Open Access Journals (Sweden)

    Monireh Mahjoob

    2014-06-01

    Full Text Available Background: Today, contact lenses have extensive usages. Contact lens places on cornea, so it may induce variation on cornea and these variations can influence the measurement of intraocular pressure (IOP by Goldman tonometer. The aim of this research was to study the effect of various contact lenses on measurement of intraocular pressure by Goldman tonometer. Materials and Methods: In this study, 80 subjects aged 18-25 were selected randomly among patients of Al-Zahra ophthalmology center. None of them has any eye pathological problems. Before wearing the lens, intraocular pressure was measured, and then patients were divided into two groups of soft and hard contact lenses. Soft and hard contact lenses were placed on the eye for two hours, and the intraocular pressure was measured again. Results: The mean of IOP before wearing contact lenses and two hours later was 15.96 mmHg and 13.93, s respectively. Paired test showed a significant difference between IOP before and after wearing contact lenses (p=0.001.There was no significant differences in mean of intraocular pressure decline before and after placing the contact lens in both soft and hard lenses. Conclusion: According to this study, the intraocular pressure decreases after wearing contact lenses (CL. This decline may be due to variation in properties of cornea after wearing CL that can also affect IOP measurement.

  18. Magnetic resonance imaging diagnosis of intraocular lenses. Die kernspintomographische Diagnostik der Hinterkammerlinse

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Bleckmann, H. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany)); Kaczmarek, U. (Strahlenklinik und Poliklinik, Universitaetsklinik Rudolf Virchow, Berlin (Germany))

    1994-09-01

    Intraocular lenses were investigated by MRI to obtain information about the quality of this method. In experimental studies, seven lenses of between 0 and 30 diopters were visualized. By MRI it was possible to differentiate the various diameters of lenses. It was not possible to discriminate the material of the intraocular lenses. After these first studies the eyes of two corpses and eight patients were investigated. Because of the resolution of MRI it was possible to tell the diopter of implanted lenses. However, by use of MRI in the regular position, a tilting or decentration of the intraocular lens was demonstrated. (orig.)

  19. Electrochemical lysis at the stage of endoresection for large posterior intraocular tumors

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2012-01-01

    Full Text Available Purpose: to design the new combined technique of endoresection with intraoperative intraocular electrochemical lysis at the tumor destruction stage for large posterior intraocular tumors.Methods: 3 patients (3 eyes with large choroidal melanomas t3N0M0 (tumor thickness — 8-10 mm, base diameter — 13-15 mm, juxtapapillary localization. Mean age was 55.4 years old. Endoresection with intraoperational intraocular electrochemical lysis of the tumor was performed. Electrochemical lysis was performed with use of the technical unit ECU 300 (Soering, Germany and the original method of combined intratumoral positioning of two platinum electrodes: anode and cathode.Results: the tumor was removal completely in all 3 cases. the anatomical retinal reattachment was reached in all patients. Sclera was safe in all 3 cases. Visual acuity was not changed (NLP. At the place of the removal tumor a surgical choroidal coloboma without pigmentation all over scleral bed and periphery was shown in all cases in distant postoperative period (from 1.5 to 3 years. No local recurrences or metastasis were revealed in all patients.Conclusion: Further investigations in clinical group are necessarily to determinate the real possibilities of the combined method and the indications for endoresection with intraoperative intraocular electrochemical lysis for large intraocular tumors. 

  20. The Effects of Hashimoto Thyroiditis on Lymph Node Metastases in Unifocal and Multifocal Papillary Thyroid Carcinoma

    Science.gov (United States)

    Zhu, Feng; Shen, Yi Bin; Li, Fu Qiang; Fang, Yun; Hu, Liang; Wu, Yi Jun

    2016-01-01

    Abstract The purpose of this study was to investigate the risk factors for central and lateral neck lymph node metastases in papillary thyroid carcinoma (PTC) and multifocal papillary thyroid carcinoma (MPTC), particularly when associated with Hashimoto thyroiditis (HT). A retrospective analysis of 763 consecutive patients who underwent total thyroidectomy with bilateral central neck dissection in the First Affiliated Hospital, College of Medicine, Zhejiang University between October 2011 and October 2014 was conducted. All patients had formal histological diagnoses of HT. Multivariable logistic regression analysis was performed to identify risk factors of neck lymph node metastases. Our study identified 277 PTC patients with HT and showed comparatively low rates of central lymph node metastases (CLNM) compared with the PTC patients without HT (37.2% versus 54.7%, P thyroid peroxidase antibody >140 IU/mL was established as the most sensitive and specific level for the prediction of MPTC based on receiver operating characteristic curve analyses. Thyroid peroxidase antibody, age, tumor size, and multifocality exhibited the ability to predict CLNM in PTC with HT patients with an area under the curve of 81.1% based on a multivariate model. Hashimoto thyroiditis was associated with increased prevalences of multifocality and capsular invasion. In contrast, HT was associated with a reduced risk of CLNM in PTC and MPTC patients, which indicated a potential protective effect. We found that the prognostic prediction model was applicable for predicting multifocality and CLNM in PTC patients with HT. PMID:26871795

  1. Phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism.

    Science.gov (United States)

    Dávila, Pedro J; Ulloa-Padilla, Jan P; Izquierdo, Natalio J

    2017-01-01

    To evaluate the benefits of phacoemulsification and intraocular lens implantation in patients with oculocutaneous albinism (OCA). The charts of 195 patients with OCA who visited a local eye clinic were reviewed. All of these patients had genetic linkage analysis to establish OCA type. Frequencies and Paired t-test analysis were determined. Of the 195 patients, nine (4.6%) underwent clear cornea phacoemulsification with intraocular lens implantation. Seven of the nine patients with OCA had the Hermansky-Pudlak (HPS) type 1; two had OCA type 1. Pre-operative BCVA of all eyes ranged from 1.0 to 2.3 logMAR with a mean of 1.42 logMAR and a standard deviation of 0.41 logMAR. Post-operative BCVA of all eyes ranged from 1.0 to 1.30 logMAR with a mean of 1.04 logMAR and a standard deviation of 0.10 logMAR. BCVA improved after phacoemulsification surgery and intraocular lens implantation (p = 0.002). Pre-operative astigmatism of all eyes ranged from +0.50 to +5.75 with a mean of +2.25 and a standard deviation of +2.40. Post-operative astigmatism of all eyes ranged from +0.50 to +2.00 with a mean of +1.23 and a standard deviation of +0.42. Astigmatism improved after phacoemulsification surgery and intraocular lens implantation (p = 0.05). Nine patients with OCA who underwent phacoemulsification and intraocular lens implant experienced improved visual acuity and reduced astigmatism post-operatively. These results suggest cataract surgery may improve vision and refractive errors, and thus quality of life, in patients with albinism.

  2. Primary multifocal tuberculous osteomyelitis with involvement of the ribs

    Energy Technology Data Exchange (ETDEWEB)

    Chang, D.S. [New York University School of Medicine, New York, New York (United States); Rafii, M.; McGuinness, G. [Department of Radiology, NYU Medical Center, New York, NY (United States); Jagirdar, J.S. [Department of Pathology, NYU Medical Center, New York, New York (United States)

    1998-11-01

    Two cases of primary multifocal tuberculous osteomyelitis with involvement of the rib cage are presented. The lungs were normal and the appearance of the skeletal lesions did not suggest tuberculosis. These lesions were predominantly lytic, with minimal soft tissue involvement. Tuberculosis should be high in the differential diagnosis of multiple destructive bone lesions, especially in patients from regions where tuberculosis is endemic. (orig.) With 5 figs., 21 refs.

  3. [Changes in intraocular pressure depending on posture].

    Science.gov (United States)

    Barac, Ramona; Pop, Monica; Tătaru, C; Gheorghe, A; Bădescu, Silvia; Stanciu, Maria; Burcea, M

    2014-01-01

    Glaucoma is an important eye disease that, left untreated, causes irreversible blindness by affecting optic nerve threads. Decreasing intraocular pressure and maintaining it at a low level throughout the day is one of the objectives of antiglaucoma therapy. This is a prospective study conducted on a sample of 80 patients who presented at "Emergency Eye Hospital" Bucharest between 1st of December 2013 30th of July 2014. Patients were divided into two groups: 40 patients with glaucoma and 40 patients without glaucoma (control group). THE OBJECTIVE OF THE STUDY: To determine changes in intraocular pressure that may occur depending on body posture and the correlations between changes in intraocular pressure and glaucoma, obesity, hypertension. These IOP changes may be important in the progression of glaucoma regarding that one third of our time is spent on supine position during night. RESULTS AND CONCLUZIONS: IOP varies from sitting down to supine position. IOP increases in supine in most patients (with or without glaucoma) with an average of 1.25 mmHg. The increase among patients with glaucoma is higher (1.67 mmHg) compared to those without glaucoma (0.82 mmHg). In patients with hypertension and glaucoma, IOP increased with 2.62 mmHg. In patients with hypertension and obesity IOP increased with 2.5 mmHg.

  4. Near-infrared transillumination photography of intraocular tumours.

    Science.gov (United States)

    Krohn, Jørgen; Ulltang, Erlend; Kjersem, Bård

    2013-10-01

    To present a technique for near-infrared transillumination imaging of intraocular tumours based on the modifications of a conventional digital slit lamp camera system. The Haag-Streit Photo-Slit Lamp BX 900 (Haag-Streit AG) was used for transillumination photography by gently pressing the tip of the background illumination cable against the surface of the patient's eye. Thus the light from the flash unit was transmitted into the eye, leading to improved illumination and image resolution. The modification for near-infrared photography was done by replacing the original camera with a Canon EOS 30D (Canon Inc) converted by Advanced Camera Services Ltd. In this camera, the infrared blocking filter was exchanged for a 720 nm long-pass filter, so that the near-infrared part of the spectrum was recorded by the sensor. The technique was applied in eight patients: three with anterior choroidal melanoma, three with ciliary body melanoma and two with ocular pigment alterations. The good diagnostic quality of the photographs made it possible to evaluate the exact location and extent of the lesions in relation to pigmented intraocular landmarks such as the ora serrata and ciliary body. The photographic procedure did not lead to any complications. We recommend near-infrared transillumination photography as a supplementary diagnostic tool for the evaluation and documentation of anteriorly located intraocular tumours.

  5. Intraocular pressure measurement: Goldmann Applanation Tonometer vs non contact airpuff tonometer.

    Science.gov (United States)

    Shah, Masood Alam; Bin Saleem, Khalid; Mehmood, Talat

    2012-01-01

    An accurate assessment of Intraocular pressure (IOP) is vital in establishing diagnosis of Glaucoma and decision making regarding various treatment modalities available. The purpose of this study is to compare Goldmann Applanation Tonometer (GAT) with Air puff tonometer. Cross-sectional comparative study conducted. 73 eyes from 73 patients were included in this study and intraocular pressure (IOP) was measured by GAT and PT100 at Sheikh Khalifa Bin Zayed Hospital, Muzaffarabad, Benazir Shaheed Teaching Hospital, Abbottabad. Mean age of the patients was 53.17 +/- 13.80 years. Mean IOP measurements showed significant differences in measurements performed by the two tonometers (p contact air-puff tonometer, the Goldmann applanation tonometer is a reliable and consistent technique for measurement of intraocular pressure.

  6. Ocular onchocerciasis in the Yanomami communities from Brazilian Amazon: effects on intraocular pressure.

    Science.gov (United States)

    Herzog-Neto, Guilherme; Jaegger, Karen; Nascimento, Erika S do; Marchon-Silva, Verônica; Banic, Dalma M; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and microfilariae in the anterior chamber were found in ∼28%. The mean of intraocular eye pressure found was 10.47 mm of Hg.

  7. The effect of high- to low-altitude adaptation on the multifocal electroretinogram

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Sander, Birgit; Zubieta-Calleja, Gustavo

    2009-01-01

    PURPOSE: To examine variations in retinal electrophysiology assessed by multifocal electroretinogram (mfERG) during acclimatization of native highlanders to normobaric normoxia at sea level. METHODS: Eight healthy residents of the greater La Paz area in Bolivia (3600 m above sea level) were...

  8. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  9. Multifocal oral melanoacanthoma associated with Addison's disease and hyperthyroidism: a case report.

    Science.gov (United States)

    Dantas, Thinali Sousa; Nascimento, Isabelly Vidal do; Verde, Maria Elisa Quezado Lima; Alves, Ana Paula Negreiros Nunes; Sousa, Fabrício Bitu; Mota, Mário Rogério Lima

    2017-01-01

    Oral melanoacanthoma is a mucocutaneous, pigmented, rare, benign, and probably reactive lesion. This paper reports for the first time in the literature a case of multifocal oral melanoacanthoma in a patient diagnosed with Addison's disease and concomitant Graves' disease with hyperthyroidism. The patient presented with oral pigmented lesions, which were hypothesized to be mucosal pigmentation associated with Addison's disease. Due to their unusual clinical pattern, these oral lesions were biopsied and diagnosed as oral melanoacanthoma on histopathology and immunohistochemistry for HMB-45. At the moment of this report, the patient was being treated for her systemic conditions, but the lesions had not regressed. Reactive hyperpigmentation of the skin and mucous membranes may be found in Addison's disease and hyperthyroidism. This case reinforces the hypothesis of a reactive nature for oral melanoacanthoma and highlights the need for investigation of endocrine disorders in patients with multifocal oral melanoacanthoma.

  10. Intraocular Pressure Increases After Intraarticular Knee Injection With Triamcinolone but Not Hyaluronic Acid.

    Science.gov (United States)

    Taliaferro, Kevin; Crawford, Alexander; Jabara, Justin; Lynch, Jonathan; Jung, Edward; Zvirbulis, Raimonds; Banka, Trevor

    2018-03-09

    Intraarticular steroid injections are a common first-line therapy for severe osteoarthritis, which affects an estimated 27 million people in the United States. Although topical, oral, intranasal, and inhalational steroids are known to increase intraocular pressure in some patients, the effect of intraarticular steroid injections on intraocular pressure has not been investigated, to the best of our knowledge. If elevated intraocular pressure is sustained for long periods of time or is of sufficient magnitude acutely, permanent loss of the visual field can occur. How does intraocular pressure change 1 week after an intraarticular knee injection either with triamcinolone acetonide or hyaluronic acid? A nonrandomized, nonblinded prospective cohort study was conducted at an outpatient, ambulatory orthopaedic clinic. This study compared intraocular pressure elevation before and 1 week after intraarticular knee injection of triamcinolone acetonide versus hyaluronic acid for management of primary osteoarthritis of the knee. Patients self-selected to be injected in their knee with either triamcinolone acetonide or hyaluronic acid before being informed of the study. The primary endpoint was intraocular pressure elevation of ≥ 7 mm Hg 1 week after injection. This cutoff is determined as the minimum significant pressure change in the ophthalmology literature recognized as an intermediate responder to steroids. Intraocular pressure was measured using a handheld Tono-Pen® applanation device. This device is frequently used in intraocular pressure measurement in clinical and research settings; 10 sequential measurements are obtained and averaged with a confidence interval. Only measurements with a 95% confidence interval were used. Over a 6-month period, a total of 96 patients were approached to enroll in the study. Sixty-two patients out of 96 approached (65%) agreed. Thirty-one (50%) were injected with triamcinolone and 31 (50%) were injected with hyaluronic acid. Patients

  11. Intraocular gnathostomiasis: report of a case and review of literature.

    Science.gov (United States)

    Pillai, Gopal S; Kumar, Anil; Radhakrishnan, Natasha; Maniyelil, Jayasree; Shafi, Tufela; Dinesh, Kavitha R; Karim, Shamsul

    2012-04-01

    Intraocular gnathostomiasis is a rare parasitic infection caused by the third-stage larvae of spiruroid nematode Gnanthostoma spp. seen mostly in tropical and subtropical regions. It is a food-borne zoonosis caused by ingestion of raw or undercooked freshwater fish, amphibians, reptiles, birds, and mammals, all of which are known to harbor advanced third-stage larvae of Gnanthostoma spp. To date, 74 cases of intraocular gnathostomiasis have been reported from 12 different countries. Only four countries have reported more than 10 cases each, and India shares the rare distinction of being one of them, with 14 cases. Surprisingly, not a single case of cutaneous gnanthostomiasis has ever been reported from India. We present one such case of intraocular gnathostomiasis in a 41-year-old male who presented with an actively motile worm attached to the iris, and we review the pertinent literature of all such cases reported from India.

  12. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  13. Microscopic and spectroscopic investigation of an explanted opacified intraocular lens

    Energy Technology Data Exchange (ETDEWEB)

    Simon, V., E-mail: viosimon@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Radu, T.; Vulpoi, A. [Babeş-Bolyai University, Faculty of Physics and Interdisciplinary Research Institute on Bio-Nano-Sciences, 400084 Cluj-Napoca (Romania); Rosca, C. [Optilens Clinic of Ophthalmology, 400604 Cluj-Napoca (Romania); Eniu, D. [Iuliu Haţieganu University of Medicine and Pharmacy, Department of Molecular Sciences, 400349 Cluj-Napoca (Romania)

    2015-01-15

    Highlights: • Changes on intraocular lens (IOL) surface after implantation. • Partial opacification of IOL central area. • Elemental composition on IOL surface prior to and after implantation. • First XPS depth profiling examination of the opacifying deposits. • Cell-mediated hydroxyapatite structuring. - Abstract: The investigated polymethylmethacrylate intraocular lens explanted an year after implantation presented a fine granularity consisting of ring-like grains of about 15 μm in diameter. In order to evidence the changes occurred on intraocular lens relative to morphology, elemental composition and atomic environments, microscopic and spectroscopic analyses were carried out using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), energy-dispersive X-ray (EDS), and X-ray photoelectron (XPS) spectroscopies. The results revealed that the grains contain hydroxyapatite mineral phase. A protein layer covers the lens both in opacified and transparent zones. The amide II band is like in basal epithelial cells. The shape and size of the grains, and the XPS depth profiling results indicate the possibility of a cell-mediated process involving lens epithelial cells which fagocitated apoptotic epithelial cells, and in which the debris derived from cell necrosis were calcified. To the best of our knowledge, this is the first investigation on explanted intraocular lenses using XPS depth profiling in order to examine the inside of the opacifying deposits.

  14. Intravitreal triamcinolone for intraocular inflammation and associated macular edema

    Directory of Open Access Journals (Sweden)

    Steven M Couch

    2008-11-01

    Full Text Available Steven M Couch, Sophie J BakriMayo Clinic Department of Ophthalmology, Mayo Clinic, Rochester, MN, USAAbstract: Triamcinolone acetonide (TA is a corticosteroid that has many uses in the treatment of ocular diseases because of its potent anti-inflammatory and anti-permeability actions. Intraocular inflammation broadly referred to as uveitis can result from several causes, including the immune system and after ophthalmic surgery. One of the most common reasons for vision loss with uveitis is macular edema. TA has been used for many years as an intravitreal injection for the treatment of ocular diseases. Several case control studies have been reported showing the efficacy of TA in the treatment of intraocular inflammation and associated macular edema caused by Behcet’s disease, Vogt-Koyanagi-Harada syndrome, sympathetic ophthalmia and white dot syndromes. It has also been shown efficacious in cases of pars planitis and idiopathic posterior uveitis. Some authors have reported its use in postoperative cystoid macular edema. Many of the studies on the use of TA in controlling intraocular inflammation and concomitant macular edema showed its effect to be transient in many patients requiring reinjection. Complications can arise from intravitreal injection of TA including elevated intraocular pressure and cataract. Rarely, it can be associated with infectious and non-infectious endophthalmitis. TA may be useful as an adjuvant in the treatment of uveitis and its associated macular edema, especially in patients resistant or intolerant to standard treatment.Keywords: triamcinolone acetonide, Behcet’s disease, sympathetic ophthalmia, Vogt-Koyanagi-Harada syndrome, white dot syndromes, uveitis, cataract surgery, macular edema, endophthalmitis

  15. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  16. Outcomes and Complications of Scleral-Fixated Intraocular Lens Combined with Ahmed Tube Surgery

    Directory of Open Access Journals (Sweden)

    Nikhel Sachdev

    2018-01-01

    Full Text Available Background. To evaluate the outcome and complications of transscleral suture-fixated posterior chamber intraocular lens (PCIOL implantation combined with Ahmed glaucoma valve (AGV surgery in Asian eyes. Design. This was a retrospective study that included 22 eyes from 22 participants. The surgeries were performed at Singapore’s National University Hospital. Participants underwent an Ahmed tube surgery, together with transscleral suture-fixated posterior chamber intraocular lens. Main Outcome Measures. Complete success was defined as 6 ≤ intraocular pressure (IOP ≤ 21 mmHg without medications at the last follow-up visit, with no reoperation required and no progression to no perception of light (NPL. Results. At the last follow-up, there was a significant reduction in mean IOP (22.4 ± 6.5 mmHg versus 13.9 ± 3.9 mmHg; p<0.001 and mean number of intraocular pressure-lowering medications (2.45 ± 1.30 versus 0.05 ± 0.21; p<0.001. There was no significant change in visual acuity [1.43 ± 1.21 (LogMAR versus 1.09 ± 1.31 (p=0.204]. Sixteen eyes (72.7% achieved complete success. The 3 commonest complications were bullous keratopathy, choroidal detachment, and displacement of intraocular lens. Conclusion and Relevance. This technique showed good success for intraocular pressure control and vision preservation. Postoperative complications were relatively common although most were self-limiting. Patients at increased risk of trabeculectomy failure may be suitable for this procedure.

  17. Intraocular foreign-body hazard during vitrectomy.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1982-03-01

    We noted two instances of forceps-induced fragmentation of the bar used for scleral plug storage during vitreous surgery. The silicone bar material was adherent to the plug in both cases. Because this represents a significant intraocular foreign body hazard, the scleral plug should be carefully inspected before insertion.

  18. Radioembolization After Portal Vein Embolization in a Patient with Multifocal Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Burgmans, Mark C.; Irani, Farah G.; Chan, Wan Ying; Teo, Terence K.; Kao, Yung Hsiang; Goh, Anthony S.W.; Chow, Pierce K.; Lo, Richard H.

    2012-01-01

    Radioembolization is an effective locoregional therapy for patients with intermediate or advanced stage hepatocellular carcinoma (HCC). It has been shown that radioembolization is safe in patients with portal vein thrombosis. This case report describes safe radioembolization after portal vein embolization in a patient with multifocal HCC.

  19. Multifocal amelanotic conjunctival melanoma and acquired melanosis sine pigmento.

    Science.gov (United States)

    Paridaens, A D; McCartney, A C; Hungerford, J L

    1992-03-01

    Clinical and histopathological features of four cases of multifocal amelanotic malignant melanoma of the conjunctiva in association with 'acquired melanosis sine pigmento' are reported. The absence of conjunctival pigmentation in this extremely rare combination of lesions prevented early diagnosis and clinical monitoring. As a result orbital exenteration was required in three cases. This multicentric non-pigmented variety of conjunctival malignant melanoma tends to present later than pigmented forms and may require exenteration of the orbit as a primary procedure.

  20. Bilateral Acute Angle-closure after Intraocular Surgery.

    Science.gov (United States)

    Hoskens, Kirsten; Pinto, Luis Abegão; Vandewalle, Evelien; Verdonk, Nancy; Stalmans, Ingeborg

    2014-01-01

    We report the case of a 75-year-old woman who developed an acute bilateral angle-closure associated with choroidal effusion a day after an uneventful cataract surgery. The same patient had undergone a similarly uneventful cataract surgery two weeks before, under the same protocol, with no postoperative complication in the other eye. Medical treatment, including the use of oral sulfamide-related drugs (acetazolamide), topical beta-blockers and steroids led to a gradual decrease in intraocular pressure (IOP) and choroidal effusion. Despite initial reports suggesting a link between sulfamide-exposure and these rare forms of angle-closure, our report would suggest a more complex pathophysiology behind this intriguing phenomenon. How to cite this article: Hoskens K, Pinto LA, Vandewalle E, Verdonk N, Stalmans I. Bilateral Acute Angle-closure after Intraocular Surgery. J Curr Glaucoma Pract 2014;8(3):113-114.

  1. Changes of intraocular pressure in different trimesters of pregnancy among Syrian refugees in Turkey: A cross-sectional study.

    Science.gov (United States)

    Tolunay, Harun Egemen; Özcan, Sait Coşkun; Şükür, Yavuz Emre; Özarslan Özcan, Deniz; Adıbelli, Fatih Mehmet; Hilali, Neşe Gül

    2016-06-01

    To evaluate the physiologic changes in intraocular pressure associated with pregnancy in healthy Syrian refugee women in Turkey. In this cross-sectional study, intraocular pressures were measured using a Goldmann tonometer in 235 patients in the first, second, and third trimester of pregnancy and puerperium among Syrian refugees in Turkey. Mean intraocular pressures values of the right eye were 15.5±2.5 mmHg, 14.4±1.4 mmHg, 13.9±1.6 and 14.7±1.9 mmHg in the three trimesters and puerperium, respectively. Mean intraocular pressures values of the left eye were 15.3±1.6 mmHg, 14.3±1.4 mmHg, 13.9±1.6 and 15.3±2.2 mmHg in the three trimesters and puerperium, respectively. The mean intraocular pressures values measured from both eyes were significantly higher in first trimester and puerperal period than in the third trimester (p<0.001). Changes in the intraocular pressure in pregnancy are common and temporary. This study shows the baseline changes in the intraocular pressure during pregnancy in healthy women. Therefore, we cannot extrapolate the results to the whole eye. A decrease in intraocular pressures was shown in healthy pregnant women.

  2. INTRAOCULAR TRANSMISSIBLE VENEREAL TUMOR IN A DOG TUMOR VENÉREO TRANSMISSÍVEL INTRA-OCULAR EM CÃO

    Directory of Open Access Journals (Sweden)

    Geórgia Nadalini Rodrigues

    2001-02-01

    Full Text Available Canine transmissible venereal tumor (TVT is a round cell neoplasm occurring on the external genital mucosa of male and female dogs. Transmission is by cell implantation during coitus, licking, or other interaction between an affected dog and a susceptible host. Metastasis of the tumor rarely occurs. This report describes an unusual presentation of TVT with intraocular involvement and inguinal lymph nodes metastasis. The subject was a six-year-old, intact, male, Brazilian Terrier dog with a history of abnormal masses in the right eye, penis and several subcutaneous nodules in the inguinal area. Histopathological examination of the eye specimens as well as cytologic examination of penile mass and subcutaneous nodules revealed similar findings. The examination revealed round cells containing a large nuclei with prominent, central located nucleoli and a pale cytoplasm containing few small, clear round vacuoles. Histologically, the subcutaneous nodules in the inguinal area were lymph nodes. The diagnosis of TVT with intraocular involvement and lymph nodes metastasis was based on clinical, cytologic and histopathologic findings.Tumor venéreo transmissível (TVT é uma neoplasia de células redondas que acomete a mucosa genital externa de cães, machos e fêmeas. A transmissão decorre da implantação de células tumorais durante o coito, brigas ou interações entre animais portadores e susceptíveis. Existem relatos referindo-se a localizações atípicas do TVT, mas metástases raramente ocorrem. O presente relato descreve um caso incomum de TVT, com acometimento intra-ocular e metástases nos linfonodos ingüinais, num cão Terrier Brasileiro, com seis anos de idade. O animal apresentava massas anormais de tecido no olho direito, extremidade do pênis e aumento de volume de linfonodos da região ingüinal. A histopatologia do globo ocular e as citologias da massa peniana e dos nódulos subcutâneos evidenciaram aspectos citológicos semelhantes

  3. Correction to: Progressive multifocal leukoencephalopathy in rituximab-treated rheumatic diseases: a rare event.

    Science.gov (United States)

    Berger, Joseph R; Malik, Vineeta; Lacey, Stuart; Brunetta, Paul; Lehane, Patricia B

    2018-04-10

    The article "Progressive multifocal leukoencephalopathy in rituximab-treated rheumatic diseases: a rare event," written by Joseph R. Berger, Vineeta Malik, Stuart Lacey, Paul Brunetta, and Patricia B. Lehane 3 , was originally published electronically on the publisher's internet portal (currently SpringerLink).

  4. Multifocal choroiditis as the first sign of systemic sarcoidosis associated with pembrolizumab

    Directory of Open Access Journals (Sweden)

    Qu-Knafo Lise

    2017-04-01

    Conclusions and importance: Pembrolizumab is an immune checkpoint inhibitor therapy used in the treatment of metastatic melanoma. We report a pembrolizumab-associated sarcoidosis revealed by a panuveitis with multifocal choroiditis. Physicians should be aware of the potential inflammatory and autoimmune disease that may be induced by immunomodulatory therapies.

  5. Optical design of soft multifocal contact lens with uniform optical power in center-distance zone with optimized NURBS.

    Science.gov (United States)

    Vu, Lien T; Chen, Chao-Chang A; Yu, Chia-Wei

    2018-02-05

    This study aims to develop a new optical design method of soft multifocal contact lens (CLs) to obtain uniform optical power in large center-distance zone with optimized Non-Uniform Rational B-spline (NURBS). For the anterior surface profiles of CLs, the NURBS design curves are optimized to match given optical power distributions. Then, the NURBS in the center-distance zones are fitted in the corresponding spherical/aspheric curves for both data points and their centers of curvature to achieve the uniform power. Four cases of soft CLs have been manufactured by casting in shell molds by injection molding and then measured to verify the design specifications. Results of power profiles of these CLs are concord with the given clinical requirements of uniform powers in larger center-distance zone. The developed optical design method has been verified for multifocal CLs design and can be further applied for production of soft multifocal CLs.

  6. [Hormonal homeostasis and intraocular pressure in chronic emotional stress caused by influences acting on the amygdala].

    Science.gov (United States)

    Isakova, L S; Danilov, G E; Egorkina, S B; Butolin, E G

    1989-01-01

    Changes in intraocular pressure, eye hydrodynamics and the amount of hypophyseal, thyroid, adrenal and pancreatic hormones were studied during continuous stimulation of amygdaloid complex or after administration of angiotensin II into the structure in rabbits. The effects involved changes in hormonal homeostasis and elevation of intraocular pressure due to a hypersecretion of intraocular fluid. The administration of angiotensin II during the amygdala stimulation enhanced the changes.

  7. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  8. MRI and intraocular tamponade media

    Energy Technology Data Exchange (ETDEWEB)

    Manfre, I. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Fabbri, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Avitabile, T. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Biondi, P. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Reibaldi, A. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Pero, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy))

    1993-05-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  9. MRI and intraocular tamponade media

    International Nuclear Information System (INIS)

    Manfre, I.; Fabbri, G.; Avitabile, T.; Biondi, P.; Reibaldi, A.; Pero, G.

    1993-01-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  10. Power Profiles of Commercial Multifocal Soft Contact Lenses.

    Science.gov (United States)

    Kim, Eon; Bakaraju, Ravi C; Ehrmann, Klaus

    2017-02-01

    To evaluate the optical power profiles of commercially available soft multifocal contact lenses and compare their optical designs. The power profiles of 38 types of multifocal contact lenses-three lenses each-were measured in powers +6D, +3D, +1D, -1D, -3D, and -6D using NIMO TR1504 (Lambda-X, Belgium). All lenses were measured in phosphate buffered saline across 8 mm optic zone diameter. Refractive index of each lens material was measured using CLR 12-70 (Index Instruments, UK), which was used for converting measured power in the medium to in-air radial power profiles. Three basic types of power profiles were identified: center-near, center-distance, and concentric-zone ring-type designs. For most of the lens types, the relative plus with respect to prescription power was lower than the corresponding spectacle add. For some lens types, the measured power profiles were shifted by up to 1D across the power range relative to their labeled power. Most of the lenses were designed with noticeable amounts of spherical aberration. The sign and magnitude of spherical aberration can either be power dependent or consistent across the power range. Power profiles can vary widely between the different lens types; however, certain similarities were also observed between some of the center-near designs. For the more recently released lens types, there seems to be a trend emerging to reduce the relative plus with respect to prescription power, include negative spherical aberration, and keep the power profiles consistent across the power range.

  11. Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses.

    Science.gov (United States)

    Plaza-Puche, Ana B; Alió, Jorge L; MacRae, Scott; Zheleznyak, Len; Sala, Esperanza; Yoon, Geunyoung

    2015-05-01

    To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrys of group: r = -0.99, P < .01). Linear predicting models were obtained. Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis. Copyright 2015, SLACK Incorporated.

  12. Progressive Multifocal Leukoencephalopathy: Recent Advances and a Neuro-Ophthalmological Review.

    Science.gov (United States)

    Sudhakar, Padmaja; Bachman, David M; Mark, Alexander S; Berger, Joseph R; Kedar, Sachin

    2015-09-01

    Progressive multifocal leukoencephalopathy (PML) is a severe often fatal opportunistic infection of the central nervous system caused by reactivation of a ubiquitous polyoma virus, JC virus. Although typically characterized by multifocal asymmetric subcortical white matter lesions, it may be monofocal and affect the cortical gray matter. Among the broad spectrum of clinical manifestations that occurs with PML, visual complaints are common. Combination of representative personally observed cases of PML and comprehensive review of case series of PML from 1958 through 2014. Neuro-ophthalmic signs and symptoms were reported in approximately 20%-50% of patients with PML and can be the presenting manifestation in half of these. A majority of these presentations occur from damage to cerebral visual pathways resulting in visual field defects, cortical blindness, and other disorders of visual association. Given the decreased frequency of infratentorial and cerebellar involvement, ocular motility disorders are less common. Visual complaints occur in patients with PML and are often the presenting sign. Awareness of this condition is helpful in avoiding unnecessary delays in the diagnosis of PML and management of the underlying condition. Recent guidelines have established criteria for diagnosis of PML in the high-risk patient population and strategies to mitigate the risk in these populations.

  13. Wide-field two-dimensional multifocal optical-resolution photoacoustic computed microscopy

    Science.gov (United States)

    Xia, Jun; Li, Guo; Wang, Lidai; Nasiriavanaki, Mohammadreza; Maslov, Konstantin; Engelbach, John A.; Garbow, Joel R.; Wang, Lihong V.

    2014-01-01

    Optical-resolution photoacoustic microscopy (OR-PAM) is an emerging technique that directly images optical absorption in tissue at high spatial resolution. To date, the majority of OR-PAM systems are based on single focused optical excitation and ultrasonic detection, limiting the wide-field imaging speed. While one-dimensional multifocal OR-PAM (1D-MFOR-PAM) has been developed, the potential of microlens and transducer arrays has not been fully realized. Here, we present the development of two-dimensional multifocal optical-resolution photoacoustic computed microscopy (2D-MFOR-PACM), using a 2D microlens array and a full-ring ultrasonic transducer array. The 10 × 10 mm2 microlens array generates 1800 optical foci within the focal plane of the 512-element transducer array, and raster scanning the microlens array yields optical-resolution photoacoustic images. The system has improved the in-plane resolution of a full-ring transducer array from ≥100 µm to 29 µm and achieved an imaging time of 36 seconds over a 10 × 10 mm2 field of view. In comparison, the 1D-MFOR-PAM would take more than 4 minutes to image over the same field of view. The imaging capability of the system was demonstrated on phantoms and animals both ex vivo and in vivo. PMID:24322226

  14. Central Corneal Thickness And Its Relationship To Intra-ocular And Epidemiological Determinants

    International Nuclear Information System (INIS)

    Tayyab, A.; Masrur, A.

    2016-01-01

    Objective: To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Study Design: Cross-sectional observation study. Place and Duration of Study: Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. Methodology: The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Result: Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6 percentage (n=516) Pashtun and 48.4 percentage (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) meu m, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A ±100 μ change in central corneal thickness was associated with change in IOP of ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 meu m per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Conclusion: Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and

  15. Comparison of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients

    Directory of Open Access Journals (Sweden)

    Zhan-Jiang Liu

    2016-01-01

    Full Text Available AIM:To investigate the effects of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients. METHODS:Seventy-seven patients(128 eyeswere treated by phacoemulsification combined with intraocular lens implantation from January 2014 to March 2015 in our hospital. Thirty-nine patients(65 eyeswere treated with Bigbag intraocular lens, 38 cases(63 eyeswere treated with Rayner620H. The best corrected visual acuity(BCVAdistribution, the actual refractive value, the difference between predictive refractive value and actual refractive value and complications were measured and recorded in the two groups at 1mo after surgeries. RESULTS:The difference between the two groups on BCVA are statistically significant(PWilcoxon rank sum test. The differences between predictive refractive value and actual refractive value of the two groups were statistically significant(PPCONCLUSION:The effect of Bigbag intraocular lens for patients with phacoemulsification and intraocular lens implantation is good, and it can reduce the risk of complications.

  16. Multifocal Visual Evoked Potential in Eyes With Temporal Hemianopia From Chiasmal Compression: Correlation With Standard Automated Perimetry and OCT Findings.

    Science.gov (United States)

    Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R

    2017-09-01

    To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.

  17. Chronic recurrent multifocal osteomyelitis (CRMO)

    International Nuclear Information System (INIS)

    Schilling, F.

    1998-01-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is an unusual clinical entity. More than 200 cases are described in the literature and it is presented here with special reference to its radiological aspects. It is an acquired disease of the skeleton which occurs predominantly during childhood and adolescence. About ten per cent of cases begin in early or, rarely, in later adult life. This variant is described here for the first time and is discussed as 'adult CRMO'. The underlying pathology is a bland, predominantly lympho-plasma cellular osteomyelitis which is self-limiting and leads to bone sclerosis (Garre). It probably involves an abnormal immune process which follows an infection but remains clinically latent and remains aseptic and sterile. In a quarter of cases there is an association with pustulosis palmo-plantaris and its relationship with psoriatic arthropathy is discussed. The clinical, histopathological and imaging features (radiological and particularly MRT) and the bone changes are described. (orig./AJ) [de

  18. Primary Disseminated Multifocal Ewing Sarcoma: Results of the Euro-EWING 99 Trial

    NARCIS (Netherlands)

    Ladenstein, Ruth; Pötschger, Ulrike; Le Deley, Marie Cécile; Whelan, Jeremy; Paulussen, Michael; Oberlin, Odile; van den Berg, Henk; Dirksen, Uta; Hjorth, Lars; Michon, Jean; Lewis, Ian; Craft, Alan; Jürgens, Heribert

    2010-01-01

    Purpose To improve the poor prognosis of patients with primary disseminated multifocal Ewing sarcomas (PDMES) with a dose-intense treatment concept. Patients and Methods From 1999 to 2005, 281 patients with PDMES were enrolled onto the Euro-EWING 99 R3 study. Median age was 16.2 years (range, 0.4 to

  19. Late hemodynamic failure following percutaneous transluminal angioplasty for long and multifocal femoropopliteal stenoses

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Holstein, P

    1991-01-01

    separate segments were dilated. Following 98% initial technical success, 3-year patency was 68% for single short stenoses, as opposed to 20% for long and multifocal stenoses (p = 0.05, logrank test). Antiplatelet therapy with acetylsalicyclic acid was not found to influence occurrence of restenosis...

  20. Multifocal dystonia, Clinical feature of Hallervorden-Spatz

    Directory of Open Access Journals (Sweden)

    Ghelichkhani H

    1998-09-01

    Full Text Available Hallervorden-spatz disease is an inherited metabolic disorder with autosomal recessive trait. Onset is in late childhood or early adolescence. Clinical manifestation is variable but pyramidal and extrapyramidal signs are often prominent. Many of patients show progressive dementia and extrapyramidal symptoms. Ataxia or myoclonus is reported in the course of the disease in individual cases. Focal dystonias including tongue, eyelids (blepharospasm and optic atrophy, retinitis pigmentosa, rarely familial parkinsonism are also reported. Pathologically pigmentary degeneration of globus pallidus, substantia nigra (pars reticular and red nucleus is characteristic. In our case the main clinical feature was multifocal dystonia without obvious pyramidal or other extrapyramidal symptoms, and diagnosis was based on clinical and MRI findings.

  1. Evaluating the risk of eye injuries: intraocular pressure during high speed projectile impacts.

    Science.gov (United States)

    Duma, Stefan M; Bisplinghoff, Jill A; Senge, Danielle M; McNally, Craig; Alphonse, Vanessa D

    2012-01-01

    To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

  2. Stability of Adrenaline in Irrigating Solution for Intraocular Surgery.

    Science.gov (United States)

    Shibata, Yuuka; Kimura, Yasuhiro; Taogoshi, Takanori; Matsuo, Hiroaki; Kihira, Kenji

    2016-01-01

    Intraocular irrigating solution containing 1 µg/mL adrenaline is widely used during cataract surgery to maintain pupil dilation. Prepared intraocular irrigating solutions are recommended for use within 6 h. After the irrigating solution is admistered for dilution, the adrenaline may become oxidized, and this may result in a decrease in its biological activity. However, the stability of adrenaline in intraocular irrigating solution is not fully understood. The aim of this study was to evaluate the stability of adrenaline in clinically used irrigating solutions of varying pH. Six hours after mixing, the adrenaline percentages remaining were 90.6%±3.7 (pH 7.2), 91.1%±2.2 (pH 7.5), and 65.2%±2.8 (pH 8.0) of the initial concentration. One hour after mixing, the percentages remaining were 97.6%±2.0 (pH 7.2), 97.4%±2.7 (pH 7.5), and 95.6%±3.3 (pH 8.0). The degradation was especially remarkable and time dependent in the solution at pH 8.0. These results indicate that the concentration of adrenaline is decreased after preparation. Moreover, we investigated the influence of sodium bisulfite on adrenaline stability in irrigating solution. The percentage adrenaline remaining at 6 h after mixing in irrigating solution (pH 8.0) containing sodium bisulfite at 0.5 µg/mL (concentration in irrigating solution) or at 500 µg/mL (concentration in the undiluted adrenaline preparation) were 57.5 and 97.3%, respectively. Therefore, the low concentration of sodium bisulfite in the irrigating solution may be a cause of the adrenaline loss. In conclusion, intraocular irrigation solution with adrenaline should be prepared just prior to its use in surgery.

  3. Experimental research on intraocular aqueous flow by PIV method.

    Science.gov (United States)

    Yang, Hongyu; Song, Hongfang; Mei, Xi; Li, Lin; Fu, Xineng; Zhang, Mindi; Liu, Zhicheng

    2013-10-21

    Aqueous humor flows regularly from posterior chamber to anterior chamber, and this flow much involves intraocular pressure, the eye tissue nutrition and metabolism. To visualize and measure the intraocular flow regular pattern of aqueous humor. Intraocular flow in the vitro eyeball is driven to simulate the physiological aqueous humor flow, and the flow field is measured by Particle Image Velocimetry(PIV). Fluorescent particle solution of a certain concentration was infused into the root of Posterior Chamber(PC) of vitro rabbit eye to simulate the generation of aqueous and was drained out at a certain hydrostatic pressure from the angle of Anterior Chamber(AC) to represent the drainage of aqueous. PIV method was used to record and calculate the flow on the midsagittal plane of the eyeball. Velocity vector distribution in AC has been obtained, and the distribution shows symmetry feature to some extent. Fluorescent particle solution first fills the PC as it is continuously infused, then surges into AC through the pupil, flows upwards toward the central cornea, reflecting and scattering, and eventually converges along the inner cornea surface towards the outflow points at the periphery of the eyeball. Velocity values around the pupillary margin are within the range of 0.008-0.012 m/s, which are close to theoretical values of 0.0133 m/s, under the driving rate of 100 μl/min. Flow field of aqueous humor can be measured by PIV method, which makes it possible to study the aqueous humor dynamics by experimental method. Our study provides a basis for experimental research on aqueous humor flow; further, it possibly helps to diagnose and treat eye diseases as shear force damage of ocular tissues and destructions on corneal endothelial cells from the point of intraocular flow field.

  4. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  5. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    Science.gov (United States)

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P correction without additional near correction is to be recommended.

  6. Intraocular robotic interventional surgical system (IRISS): Mechanical design, evaluation, and master-slave manipulation.

    Science.gov (United States)

    Wilson, Jason T; Gerber, Matthew J; Prince, Stephen W; Chen, Cheng-Wei; Schwartz, Steven D; Hubschman, Jean-Pierre; Tsao, Tsu-Chin

    2018-02-01

    Since the advent of robotic-assisted surgery, the value of using robotic systems to assist in surgical procedures has been repeatedly demonstrated. However, existing technologies are unable to perform complete, multi-step procedures from start to finish. Many intraocular surgical steps continue to be manually performed. An intraocular robotic interventional surgical system (IRISS) capable of performing various intraocular surgical procedures was designed, fabricated, and evaluated. Methods were developed to evaluate the performance of the remote centers of motion (RCMs) using a stereo-camera setup and to assess the accuracy and precision of positioning the tool tip using an optical coherence tomography (OCT) system. The IRISS can simultaneously manipulate multiple surgical instruments, change between mounted tools using an onboard tool-change mechanism, and visualize the otherwise invisible RCMs to facilitate alignment of the RCM to the surgical incision. The accuracy of positioning the tool tip was measured to be 0.205±0.003 mm. The IRISS was evaluated by trained surgeons in a remote surgical theatre using post-mortem pig eyes and shown to be effective in completing many key steps in a variety of intraocular surgical procedures as well as being capable of performing an entire cataract extraction from start to finish. The IRISS represents a necessary step towards fully automated intraocular surgery and demonstrated accurate and precise master-slave manipulation for cataract removal and-through visual feedback-retinal vein cannulation. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Effects of phacoemulsification combined with intraocular lens implantation on ocular surface

    Directory of Open Access Journals (Sweden)

    Ming Li

    2013-10-01

    Full Text Available AIM: To explore the changes of ocular surface after phacoemulsification combined with intraocular lens implantation. METHODS: Totally 78 cases of 78 eyes with age-related cataract were collected from August 2011 to October 2012, and they underwent corneal incision phacoemulsification combined with intraocular lens implantation. The score of dry eye symptoms; tear breakup time(BUT; Schirmer Ⅰ test(SⅠtand corneal fluorescein staining were observed and recorded in 3 days before, 1 day, 1 week, 1 month, 3 and 6 months after surgery respectively. The results were analyzed statistically. RESULTS: All the subjects complained of dry eye within 1 week after surgery. Compared with 3 days before the surgery, the corneal fluorescein staining increased and the amount of tear secretion reduced statistically significant in 1 day, 1 week and 1 month(PPP>0.05, and lasted to 3 months later. CONCLUSION: Phacoemulsification combined with intraocular lens implantation has obvious effect on the ocular surface to some extent. Preventions and treatment should be taken clinically.

  8. The Visual Effects of Intraocular Colored Filters

    Directory of Open Access Journals (Sweden)

    Billy R. Hammond

    2012-01-01

    Full Text Available Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans.

  9. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Results: Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208). Conclusion: In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity. PMID:29095259

  10. [Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO].

    Science.gov (United States)

    Bültmann, S; Martin, M; Rohrschneider, K

    2002-09-01

    Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope. A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO. Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed. Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.

  11. Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

    Science.gov (United States)

    Hamed-Azzam, Shirin; Briscoe, Daniel; Tomkins, Oren; Shehedeh-Mashor, Raneen; Garzozi, Hanna

    2013-08-01

    Intraocular pressure is affected by corneal thickness and biomechanics. Following ablative corneal refractive surgery, corneal structural changes occur. The purpose of the study is to determine the relationship between the mean central corneal thickness (CCT) and the change in intraocular pressure measurements following various corneal ablation techniques, using different measurement methods. Two hundred myopic eyes undergoing laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) were enrolled into a prospective, non-randomized study. Corneal parameters examined included full ocular examination, measurement of CCT, corneal topography, corneal curvature and ocular refractivity. Intraocular pressure measurements were obtained using three different instruments-non-contact tonometer, Goldmann applanation tonometer and TonoPen XL (TonoPen-Central and TonoPen-Peripheral). All measurements were performed pre-operatively and 4 months post-operatively. Post-operative intraocular pressure was significantly lower than pre-operative values, with all instruments (p value tonometer and non-contact tonometer (p value < 0.001, ANOVA). Intraocular pressure readings are significantly reduced following corneal ablation surgery. We determined in our myopic patient cohort that the TonoPen XL intraocular pressure measurement method is the least affected following PRK and LASIK as compared to other techniques.

  12. Multifocal ERG wavelet packet decomposition applied to glaucoma diagnosis

    Directory of Open Access Journals (Sweden)

    Rodríguez-Ascariz José M

    2011-05-01

    Full Text Available Abstract Background Glaucoma is the second-leading cause of blindness worldwide and early diagnosis is essential to its treatment. Current clinical methods based on multifocal electroretinography (mfERG essentially involve measurement of amplitudes and latencies and assume standard signal morphology. This paper presents a new method based on wavelet packet analysis of global-flash multifocal electroretinogram signals. Methods This study comprised twenty-five patients diagnosed with OAG and twenty-five control subjects. Their mfERG recordings data were used to develop the algorithm method based on wavelet packet analysis. By reconstructing the third wavelet packet contained in the fourth decomposition level (ADAA4 of the mfERG recording, it is possible to obtain a signal from which to extract a marker in the 60-80 ms time interval. Results The marker found comprises oscillatory potentials with a negative-slope basal line in the case of glaucomatous recordings and a positive-slope basal line in the case of normal signals. Application of the optimal threshold calculated in the validation cases showed that the technique proposed achieved a sensitivity of 0.81 and validation specificity of 0.73. Conclusions This new method based on mfERG analysis may be reliable enough to detect functional deficits that are not apparent using current automated perimetry tests. As new stimulation and analysis protocols develop, mfERG has the potential to become a useful tool in early detection of glaucoma-related functional deficits.

  13. Osteoblastomatosis of bone. A benign, multifocal osteoblastic lesion, distinct from osteoid osteoma and osteoblastoma, radiologically simulating a vascular tumor

    International Nuclear Information System (INIS)

    Kyriakos, Michael; El-Khoury, Georges Y.; McDonald, Douglas J.; Buckwalter, Joseph A.; Sundaram, Murali; DeYoung, Barry; O'Brien, Michael P.

    2007-01-01

    Two adult patients are described with multifocal osteolytic lesions radiologically simulating a vascular tumor. One patient had multiple bones involved. Histologically, the individual lesions had the features of the nidus of osteoid osteoma/osteoblastoma. A review of the English language medical literature yielded only one other reported case with similar features. The process is designated as osteoblastomatosis to indicate its bone-forming character, prominent osteoblast proliferation, and multiplicity. The cases are distinguished from multifocal/multicentric osteoid osteoma and osteoblastoma, and from benign and malignant vascular tumors. (orig.)

  14. Clinical assessment of diclofenac sodium eye drops in toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Yan Luo

    2013-05-01

    Full Text Available AIM:To evaluate the application of diclofenac sodium eye drops in toric intraocular lens implantation. METHODS: From January 2011 to February 2012, 38 eyes of 37 patients, who underwent toric intraocular lens implantation in this hospital, were randomly divided into diclofenac sodium eye drops group(trial groupand control group. Patient's degree of cooperation during surgery and inflammation postoperation after 1 day, 3,7, days, 1 month and 3 months were evaluated. RESULTS: Patient's degree of cooperation during surgery in the trial group(1.53±0.62was significantly better than in the control group(2.40±0.88, P<0.05. Inflammation reaction was gentle in the trial group 1 day postoperatively. CONCLUSION: Diclofenac sodium eye drops used during toric intraocular lens implantation can obviously alleviate eye irritation, and increase the cooperation of patients.

  15. The role of pili in Bacillus cereus intraocular infection.

    Science.gov (United States)

    Callegan, Michelle C; Parkunan, Salai Madhumathi; Randall, C Blake; Coburn, Phillip S; Miller, Frederick C; LaGrow, Austin L; Astley, Roger A; Land, Craig; Oh, So-Young; Schneewind, Olaf

    2017-06-01

    Bacterial endophthalmitis is a potentially blinding intraocular infection. The bacterium Bacillus cereus causes a devastating form of this disease which progresses rapidly, resulting in significant inflammation and loss of vision within a few days. The outer surface of B. cereus incites the intraocular inflammatory response, likely through interactions with innate immune receptors such as TLRs. This study analyzed the role of B. cereus pili, adhesion appendages located on the bacterial surface, in experimental endophthalmitis. To test the hypothesis that the presence of pili contributed to intraocular inflammation and virulence, we analyzed the progress of experimental endophthalmitis in mouse eyes infected with wild type B. cereus (ATCC 14579) or its isogenic pilus-deficient mutant (ΔbcpA-srtD-bcpB or ΔPil). One hundred CFU were injected into the mid-vitreous of one eye of each mouse. Infections were analyzed by quantifying intraocular bacilli and retinal function loss, and by histology from 0 to 12 h postinfection. In vitro growth and hemolytic phenotypes of the infecting strains were also compared. There was no difference in hemolytic activity (1:8 titer), motility, or in vitro growth (p > 0.05, every 2 h, 0-18 h) between wild type B. cereus and the ΔPil mutant. However, infected eyes contained greater numbers of wild type B. cereus than ΔPil during the infection course (p ≤ 0.05, 3-12 h). Eyes infected with wild type B. cereus experienced greater losses in retinal function than eyes infected with the ΔPil mutant, but the differences were not always significant. Eyes infected with ΔPil or wild type B. cereus achieved similar degrees of severe inflammation. The results indicated that the intraocular growth of pilus-deficient B. cereus may have been better controlled, leading to a trend of greater retinal function in eyes infected with the pilus-deficient strain. Although this difference was not enough to significantly alter the severity

  16. Potential contact and intraocular lenses based on hydrophilic/hydrophobic sulfonated syndiotactic polystyrene membranes

    Directory of Open Access Journals (Sweden)

    Simona Zuppolini

    2017-10-01

    Full Text Available Crystalline films of syndiotactic polystyrene (s-PS, a commercially available thermoplastic polymer, having a highly hydrophilic amorphous phase, were achieved by using a mild solid-state sulfonation procedure. Despite the used mild process conditions, an easy and uniform sulfonation of the phenyl rings of the amorphous phase is obtained. The crystallinity of the polymer was not affect by the sulfonation degree (S, at least at S less than 20%, and the obtained polymer films show the nanoporous crystalline form of s-PS. As widely reported in literature, the nanoporous nature of the polymer crystalline phase gives to these materials the ability to absorb and release organic molecules of appropriate size and polarity. This property, coupled to transparency, makes these materials potentially useful intraocular lens (IOLs and contact lens applications. Sulfonation procedure and sulfonated film samples characterization by using wide-angle X-ray diffraction (WAXD, Fourier-transform infrared (FTIR and ultraviolet-visible (UV-vis spectroscopy techniques and water sorption tests were reported. Furthermore, the biocompatibility study demonstrated no cytotoxicity and appropriate cell interaction properties for the specific applications.

  17. An adult multifocal medulloblastoma with diffuse acute postoperative cerebellar swelling: immunohistochemical and molecular genetics analysis.

    Science.gov (United States)

    Balik, Vladimir; Trojanec, Radek; Holzerova, Milena; Tuckova, Lucie; Sulla, Igor; Megova, Magdalena; Vaverka, Miroslav; Hrabalek, Lumir; Ehrmann, Jiri

    2015-01-01

    Medulloblastoma (MB), the most common malignant tumor typically affecting children, occurs only exceptionally in adults. Multifocal presentation of this malignancy in adulthood is even much rarer—only four cases with favorable postoperative course have been reported, so far. The study illustrates a very rare rapid postoperative clinical deterioration due to diffuse cerebellar swelling (DCS) in an adult multifocal MB (MMB). To the best of their knowledge, authors for the first time performed genetic analysis of MMB and demonstrated expression patterns of selected markers that put the patient within the sonic hedgehog (SHH) molecular subgroup and at least partially explain her unsatisfactory clinical course. Herein, authors summarized the relevant literature concerning this issue with the aim to determine features that would facilitate diagnosis and therapy of such a scarce clinical entity.

  18. Locally Advanced Basal Cell Carcinoma with Intraocular Invasion

    Directory of Open Access Journals (Sweden)

    Georgi Tchernev

    2018-01-01

    Full Text Available We present a 103 - year - old patient, with duration of complaints of about ten years. The initial complaint had been presented as a small nodule, located on the eyebrow, which subsequently ulcerated and encompassed larger regions of the upper and lower eyelids. For the past three years, the patient also had complaints of a worsening of his vision, without seeking for medical help. Within the dermatological examination, an intraocular and periocular localised tumour was established, characterised by a raised peripheral edge and central ulceration. More careful examination revealed that the bulb was fully consumed. The patient refused further diagnosis and treatment. Advanced basal cell carcinomas with intraocular invasion are rare in general. If the patient refuses surgery, radiotherapy and systemic therapy with modern medications such as Vismodegib or Sonidegib are available as treatment options.

  19. Objective perimetry using a four-channel multifocal VEP system: correlation with conventional perimetry and thickness of the retinal nerve fibre layer.

    Science.gov (United States)

    Horn, Folkert K; Kaltwasser, Christoph; Jünemann, Anselm G; Kremers, Jan; Tornow, Ralf P

    2012-04-01

    There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern reversal dartboard). For each field, the recording from the channel with maximal signal-to-noise ratio (SNR) was retained, resulting in an SNR optimised virtual recording. Correlation with RNFL thickness, measured with spectral domain optical coherence tomography and with standard perimetry, was performed for nerve fibre bundle related areas. The mean amplitudes in nerve fibre related areas were smaller in glaucoma patients than in normal subjects. The differences between both groups were most significant in mid-peripheral areas. Amplitudes in these areas were significantly correlated with corresponding RNFL thickness (Spearman R=0.76) and with standard perimetry (R=0.71). The multifocal VEP amplitude was correlated with perimetric visual field data and the RNFL thickness of the corresponding regions. This method of SNR optimisation is useful for extracting data from recordings and may be appropriate for objective assessment of visual function at different locations. This study has been registered at http://www.clinicaltrials.gov (NCT00494923).

  20. The multifaceted presentation of chronic recurrent multifocal osteomyelitis

    DEFF Research Database (Denmark)

    Girschick, Hermann; Finetti, Martina; Orlando, Francesca

    2018-01-01

    Objectives: Chronic non-bacterial osteomyelitis (CNO) or chronic recurrent multifocal osteomyelitis (CRMO) is an autoinflammatory disorder characterized by sterile bone osteolytic lesions. The aim of this study was to evaluate the demographic data and clinical, instrumental and therapeutic features...... with glucocorticoids, 61 with bisphosphonates, 58 with MTX, 47 with SSZ, 26 with anti-TNF and 4 with anakinra, with a variable response. Conclusion: This is the largest reported case series of CNO patients, showing that the range of associated clinical manifestations is rather heterogeneous. The study confirms...... that the disease usually presents with an early teenage onset, but it may also occur in adults, even in the absence of mucocutaneous manifestations....

  1. Intraocular eyelashes and iris cyst in anterior chamber following penetrating eye injury: a case report

    Directory of Open Access Journals (Sweden)

    Sahu S

    2017-03-01

    Full Text Available Sabin Sahu,1 Lila Raj Puri,1 Sanjay Kumar Singh2 1Department of Ophthalmology, Sagarmatha Choudhary Eye Hospital, Lahan, Siraha, 2Department of Ophthalmology, Biratnagar Eye Hospital, Biratnagar, Nepal Background: The presence of intraocular eyelashes following penetrating eye injury or ocular surgery is relatively uncommon. The response of the eye to intraocular eyelashes is variable. The eyelash may be symptomatic or may remain asymptomatic for long periods. Objective: We report a case with two intraocular eyelashes and an iris cyst after 2 years of asymptomatic period following penetrating eye injury. Case presentation: A 24-year-old male presented with decreased vision in the left eye which he had noticed for the previous 2 weeks. His visual acuity was 6/6 in the right eye and 6/18 in the left eye, improving to 6/9 with -2.5 DC × 140° correction. The intraocular pressure was 12 mmHg in both eyes. On slit-lamp examination, the left eye showed 8 mm linear peripheral corneal opacity nasally, two eyelashes in the superior anterior chamber, and an iris cyst measuring 4 mm × 4 mm in the superior iris. The right eye was normal. Dilated fundus examination of both eyes was normal. The eyelashes and cyst were removed surgically. There were no complications during the 3-month follow-up period. Conclusion: Intraocular implantation of eyelashes following penetrating eye injury can remain asymptomatic for long periods; however, late development of iris cyst may occur. Keywords: intraocular eyelashes, iris cyst, penetrating eye injury

  2. Peripheral refraction with dominant design multifocal contact lenses in young myopes

    Directory of Open Access Journals (Sweden)

    Daniela Lopes-Ferreira

    2013-04-01

    Conclusion: It is possible to induce significant changes in the pattern of relative peripheral refraction in the myopic direction with commercially available dominant design multifocal contact lenses. The higher add (+3.00 D induced an significantly higher effect than the +2.00 D add lens, although an increase of 1 D in add power does not correspond to the same amount of increase in RPRE.

  3. Lentes intraoculares fácicas de câmara posterior

    Directory of Open Access Journals (Sweden)

    Mara Barreto Theiss

    Full Text Available Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A revisão criteriosa dos estudos publicados na literatura ate o momento revelam resultado satisfatórios quanto à eficácia, elevada previsibilidade, estabilidade e segurança do implante de lente intraocular de câmara posterior, para correção das miopia, hipermetropia e astigmatismo.

  4. Influência do astigmatismo corneano na acuidade visual final após implante de AcrySof® ReSTOR®: relato de caso Influence of corneal astigmatism in final visual acuity after implantation of AcrySofTM ReSTOR TM: case report

    Directory of Open Access Journals (Sweden)

    Ricardo de Carvalho Rocha

    2007-12-01

    Full Text Available Atualmente tem-se desenvolvido novos tipos de lentes intra-oculares (LIO que objetivam eliminar a presbiopia e o seu uso vem se popularizando. Descreve-se o caso de um paciente com catarata bilateral e irregularidades corneanas e astigmatismo maior que 2 D à topografia, no qual implantou-se a LIO AcrySof® ReSTOR® no olho esquerdo associado à realização de incisões limbares relaxantes para tentar diminuir o astigmatismo corneano observado. A acuidade visual pós-operatória, tanto para perto quanto para longe, ficou abaixo das expectativas, sem melhora à refração e sem uma outra alteração que a justificasse, além das citadas. Após 45 dias, sem melhora da acuidade visual, efetuou-se o explante desta LIO, seguindo-se de implante de uma monofocal, sendo observada melhora da acuidade visual corrigida final. Assim, o presente caso clínico reforça a necessidade de uma correta seleção pré-operatória dos pacientes candidatos ao implante deste tipo de LIO multifocal, atentando inclusive para os dados topográficos.Currently, new types of intraocular lenses have been developed aiming to eliminate presbyopia and the use has become more popular. The authors report the case of a patient with bilateral cataract and corneal irregularities and astigmatism higher than 2D in the corneal topography, in which AcrySofTM ReSTOR TM intraocular lens was implanted in the left eye associated to relaxing limbal incisions trying to reduce corneal astigmatism. The near and distance postoperative visual acuity were worse than expected, with no improvement with refraction. Apparently, no other reason apart from irregular astigmatism/multifocal lens justified the low vision. After 45 days, with no visual acuity improvement, the intraocular lens was explanted and a monofocal one was implanted. The final corrected visual acuity improved. Thus, the present case emphasizes the need of a correct preoperative selection of patients to implant this type of

  5. Multifocal demyelinating motor neuropathy and hamartoma syndrome associated with a de novo PTEN mutation.

    Science.gov (United States)

    Bansagi, Boglarka; Phan, Vietxuan; Baker, Mark R; O'Sullivan, Julia; Jennings, Matthew J; Whittaker, Roger G; Müller, Juliane S; Duff, Jennifer; Griffin, Helen; Miller, James A L; Gorman, Grainne S; Lochmüller, Hanns; Chinnery, Patrick F; Roos, Andreas; Swan, Laura E; Horvath, Rita

    2018-05-22

    To describe a patient with a multifocal demyelinating motor neuropathy with onset in childhood and a mutation in phosphatase and tensin homolog ( PTEN ), a tumor suppressor gene associated with inherited tumor susceptibility conditions, macrocephaly, autism, ataxia, tremor, and epilepsy. Functional implications of this protein have been investigated in Parkinson and Alzheimer diseases. We performed whole-exome sequencing in the patient's genomic DNA validated by Sanger sequencing. Immunoblotting, in vitro enzymatic assay, and label-free shotgun proteomic profiling were performed in the patient's fibroblasts. The predominant clinical presentation of the patient was a childhood onset, asymmetric progressive multifocal motor neuropathy. In addition, he presented with macrocephaly, autism spectrum disorder, and skin hamartomas, considered as clinical criteria for PTEN-related hamartoma tumor syndrome. Extensive tumor screening did not detect any malignancies. We detected a novel de novo heterozygous c.269T>C, p.(Phe90Ser) PTEN variant, which was absent in both parents. The pathogenicity of the variant is supported by altered expression of several PTEN-associated proteins involved in tumorigenesis. Moreover, fibroblasts showed a defect in catalytic activity of PTEN against the secondary substrate, phosphatidylinositol 3,4-trisphosphate. In support of our findings, focal hypermyelination leading to peripheral neuropathy has been reported in PTEN-deficient mice. We describe a novel phenotype, PTEN-associated multifocal demyelinating motor neuropathy with a skin hamartoma syndrome. A similar mechanism may potentially underlie other forms of Charcot-Marie-Tooth disease with involvement of the phosphatidylinositol pathway. Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  6. MicroRNA profiling in intraocular medulloepitheliomas.

    Directory of Open Access Journals (Sweden)

    Deepak P Edward

    Full Text Available To study the differential expression of microRNA (miRNA profiles between intraocular medulloepithelioma (ME and normal control tissue (CT.Total RNA was extracted from formalin fixed paraffin embedded (FFPE intraocular ME (n=7 and from age matched ciliary body controls (n=8. The clinical history and phenotype was recorded. MiRNA profiles were determined using the Affymetrix GeneChip miRNA Arrays analyzed using expression console 1.3 software. Validation of significantly dysregulated miRNA was confirmed by quantitative real-time PCR. The web-based DNA Intelligent Analysis (DIANA-miRPath v2.0 was used to perform enrichment analysis of differentially expressed (DE miRNA gene targets in Kyoto Encyclopedia of Genes and Genomes (KEGG pathway.The pathologic evaluation revealed one benign (benign non-teratoid, n=1 and six malignant tumors (malignant teratoid, n=2; malignant non-teratoid, n = 4. A total of 88 miRNAs were upregulated and 43 miRNAs were downregulated significantly (P<0.05 in the tumor specimens. Many of these significantly dysregulated miRNAs were known to play various roles in carcinogenesis and tumor behavior. RT-PCR validated three significantly upregulated miRNAs and three significantly downregulated miRNAs namely miR-217, miR-216a, miR-216b, miR-146a, miR-509-3p and miR-211. Many DE miRNAs that were significant in ME tumors showed dysregulation in retinoblastoma, glioblastoma, and precursor, normal and reactive human cartilage. Enriched pathway analysis suggested a significant association of upregulated miRNAs with 15 pathways involved in prion disease and several types of cancer. The pathways involving significantly downregulated miRNAs included the toll-like receptor (TLR (p<4.36E-16 and Nuclear Factor kappa B (NF-κB signaling pathways (p<9.00E-06.We report significantly dysregulated miRNAs in intraocular ME tumors, which exhibited abnormal profiles in other cancers as well such as retinoblastoma and glioblastoma. Pathway analysis

  7. Influence of gross saponins from tribulus terrestris L on SOD activity and MDA content for chronic high intraocular pressure in rabbit

    Directory of Open Access Journals (Sweden)

    Nuo Li

    2013-05-01

    Full Text Available AIM:To observe influence of gross saponins from tribulus terrestris L(GSTTon SOD activity and MDA content for chronic high intraocular pressure in rabbit, and discusses the retina oxidative damage inhibition on chronic high intraocular pressure model of rabbit. METHODS:Totally 24 healthy New Zealand rabbits were randomly divided into 4 groups: normal control group(A group; high intraocular pressure model blank group(B group; high intraocular pressure model with GSTT treated group(C group; high intraocular pressure model with Erigeron brevicapas hand mass(EBHMtreated group(D group. High intraocular pressure model was induced by 20g/L methylcellulose injection into the anterior chamber in B group, C group and D group. D group was injected 5 mg/kg GSTT and C group was injected 4.5mg/kg EBHM and measured intraocular pressure with Schiotz tonometer every day for 4 weeks. The retina tissue superoxide dismutase(SODand maleic dialdehyde(MDAcontent were detected 28 days later. RESULTS: After glaucoma model of rabbit eyes were established, the intraocular pressure during observation period was maintained in 32-39mmHg; High intraocular pressure model blank group and normal control group, EBHM treatment group, GSTT treatment group were compared, the differences of retina MDA, SOD content had statistical significance(P0.05; EBHM treatment group, GSTT treatment group and normal control group were compared, the content of MDA in the retina was still slightly higher(P<0.05, the content of SOD slightly lower(P<0.05 CONCLUSION: GSTT can effectively improve the retina SOD activity of chronic high intraocular pressure in rabbit and reduce the content of MDA, which has a protective effect of persistent high intraocular retinal oxidative stress.

  8. Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade

    Directory of Open Access Journals (Sweden)

    Mehmet Yasin Teke

    2012-05-01

    Full Text Available Many systemic and ocular factors may cause acute central retinal artery occlusion (CRAO. Herein, we aimed to describe a case of CRAO due to intraocular silicone oil (SO tamponade. To the best of our knowledge, a case like our has not been reported previously. A 58-yearold male patient had undergone combined pars plana vitrectomy-lensectomy and intraocular SO for lens luxation and vitreus hemorrhage associated with a blunt ocular trauma in his right eye. Two weeks after the surgery, he presented with acute vision loss in the same eye. He was diagnosed with acute CRAO and it should be related with mechanical press or raised intraocular pressure (IOP associated with SO. He was treated by partial removal of SO immediately. In spite of the regression of retina edema, his visual acuity did not improve due to optic atrophy. SO may cause CRAO due to raised IOP and/or its mechanical pressure and this complication must be kept in mind. (Turk J Oph thal mol 2012; 42: 238-40

  9. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    Science.gov (United States)

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  10. Effect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry Efeito das lentes intraoculares asféricas e com pigmentação amarela na campimetria azul-amarelo

    Directory of Open Access Journals (Sweden)

    Rodrigo França de Espíndola

    2012-10-01

    Full Text Available PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes received ultraviolet and blue light filter (yellow tinted IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD] investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.OBJETIVO: Investigar a possibilidade de efeitos na sensibilidade ao contraste e nos resultados da campimetria azul-amarelo com implante de uma lente intraocular (LIO asférica ou de pigmentação amarela. MÉTODOS: Trata-se de um estudo prospectivo, randomizado, duplo-mascarado, envolvendo 52 pacientes portadores de catarata senil bilateral, divididos em dois grupos; 25

  11. Ocular Onchocerciasis in the Yanomami Communities from Brazilian Amazon: Effects on Intraocular Pressure

    OpenAIRE

    Herzog-Neto, Guilherme; Jaegger, Karen; do Nascimento, Erika S.; Marchon-Silva, Verônica; Banic, Dalma M.; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and ...

  12. Intraocular osseous metaplasia. A clinico-pathological study.

    Science.gov (United States)

    Vemuganti, Geeta K; Honavar, Santosh G; Jalali, Subhadra

    2002-09-01

    To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membrane, fibrovascular proliferation and inflammation. Immunohistochemistry using monoclonal antibody against glial fibrillary acidic protein was performed to assess the glial component within the membranes and the proliferative vitreoretinal mass. Clinical records were reviewed and correlated with histopathologic findings. Osseous metaplasiaS was noted in 8 of 151 (5.2%) eyes examined. Clinical diagnosis in these was phthisis bulbi, staphyloma, absolute glaucoma and microphthalmos. Enucleation was performed for relief of symptoms (in painful blind eyes) or for cosmesis, and in an eye inciting sympathetic ophthalmia. Retinal detachment, gliosis and retinal pigment epithelial hyperplasia were noted in all the cases. Drusen with calcification or ossification (5 of 8), fibrovascular proliferation in the vitreous (5 of 8) and active inflammation (4 of 8) were the other associated histologic features. Location of ossification was subretinal in 3 cases, preretinal (ora serrata) in 1 case and in both locations in 4 cases. The eyes with subretinal osseous metaplasia had associated calcified drusen, while preretinal ossification was seen within the fibrovascular membranes. Chronic retinal detachment, hyperplasia and transdifferentiation of retinal pigment epithelium appear to be a few of the prerequisites for intraocular osseous metaplasia. Ossification can occur at isolated subretinal and preretinal locations or can involve both. Though a larger study is required to postulate the chronology of events, in

  13. Intraocular osseous metaplasia. A clinico-pathological study

    Directory of Open Access Journals (Sweden)

    Vemuganti Geeta

    2002-01-01

    Full Text Available Purpose: To evaluate the clinico-pathologic features of intraocular osseous metaplasia. Methods: Pathology specimens of enucleated eyes submitted to the ophthalmic pathology service at a tertiary eye-care referral center between January 1995 and June 1999 were studied for intraocular osseous metaplasia. Specific histopathologic features noted in specimens with osseous metaplasia were the presence of retinal detachment, gliosis, retinal pigment epithelial hyperplasia, drusen, epiretinal membrane, fibrovascular proliferation and inflammation. Immunohistochemistry using monoclonal antibody against glial fibrillary acidic protein was performed to assess the glial component within the membranes and the proliferative vitreoretinal mass. Clinical records were reviewed and correlated with histopathologic findings. Results: Osseous metaplasiaS was noted in 8 of 151 (5.2% eyes examined. Clinical diagnosis in these was phthisis bulbi, staphyloma, absolute glaucoma and microphthalmos. Enucleation was performed for relief of symptoms (in painful blind eyes or for cosmesis, and in an eye inciting sympathetic ophthalmia. Retinal detachment, gliosis and retinal pigment epithelial hyperplasia were noted in all the cases. Drusen with calcification or ossification (5 of 8, fibrovascular proliferation in the vitreous (5 of 8 and active inflammation (4 of 8 were the other associated histologic features. Location of ossification was subretinal in 3 cases, preretinal (ora serrata in 1 case and in both locations in 4 cases. The eyes with subretinal osseous metaplasia had associated calcified drusen, while preretinal ossification was seen within the fibrovascular membranes. Conclusion: Chronic retinal detachment, hyperplasia and transdifferentiation of retinal pigment epithelium appear to be a few of the prerequisites for intraocular osseous metaplasia. Ossification can occur at isolated subretinal and preretinal locations or can involve both. Though a larger study is

  14. On the retinal toxicity of intraocular glucocorticoids.

    Science.gov (United States)

    Torriglia, Alicia; Valamanesh, Fatemeh; Behar-Cohen, Francine

    2010-12-15

    Corticosteroids are hormones involved in many physiological responses such as stress, immune modulation, protein catabolism and water homeostasis. The subfamily of glucocorticoids is used systemically in the treatment of inflammatory diseases or allergic reactions. In the eye, glucocorticoides are used to treat macular edema, inflammation and neovascularization. The most commonly used glucocorticoid is triamcinolone acetonide (TA). The pharmaceutical formulation of TA is not adapted for intravitreal administration but has been selected by ophthalmologists because its very low intraocular solubility provides sustained effect. Visual benefits of intraocular TA do not clearly correlate with morpho-anatomical improvements, suggesting potential toxicity. We therefore studied, non-common, but deleterious effects of glucocorticoids on the retina. We found that the intravitreal administration of TA is beneficial in the treatment of neovascularization because it triggers cell death of endothelial cells of neovessels by a caspase-independent mechanism. However, this treatment is toxic for the retina because it induces a non-apoptotic, caspase-independent cell death related to paraptosis, mostly in the retinal pigmented epithelium cells and the Müller cells. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. Application of serum natalizumab levels during plasma exchange in MS patients with progressive multifocal leukoencephalopathy

    NARCIS (Netherlands)

    Vennegoor, A.; Rispens, T.; van Oosten, B.W.; Wattjes, M.P.; Wondergem, M.J.; Teunissen, C.E.; van der Kleij, D.; Uitdehaag, B.M.J.; Polman, C.H.; Killestein, J.

    2015-01-01

    Progressive multifocal leukoencephalopathy (PML) is a severe complication of natalizumab treatment. Restoring immune function by plasmapheresis/immunoadsorption (PLEX/IA) is important for the outcome of PML. We report on four multiple sclerosis (MS) patients whom developed PML during natalizumab

  16. Multifocal fibrosclerosis presenting as Grave's orbitopathy. Bilateral exophthalmos associated with retroperitoneal and sellar fibrosis

    NARCIS (Netherlands)

    van der Pol, R.; Nieuwenhuis, M. G.; Mourits, M. P.

    1999-01-01

    BACKGROUND: Multifocal fibrosclerosis (MF) is a rare disease that may be misdiagnosed as Graves' orbitopathy. The combination of localisations of MF presented here has not been reported before. CASE REPORT: A 44-year-old man was referred with progressive bilateral exophthalmos. CT of his chest and

  17. Multifocal epithelial hyperplasia in a community in the Mayan area of Mexico.

    Science.gov (United States)

    González-Losa, Maria R; Suarez-Allén, Rosa E; Canul-Canche, Jaqueline; Conde-Ferráez, Laura; Eljure-Lopez, Nixma

    2011-03-01

    Multifocal epithelial hyperplasia is a pathology of the oral mucosa which has been reported in diverse ethnic groups. Human papillomavirus (HPV) types 13 and 32 DNA has been detected in these lesions. The aims of this paper are to describe the epidemiological and clinical characteristics of an outbreak in a rural community in the Mayan area of Mexico and to identify a possible route of transmission through saliva. A cross-sectional study was conducted in Chemax (Yucatan, Mexico). Clinical and epidemiological data were obtained through direct interviews. Samples of oral cells and saliva were taken. HPV 13 and 32 were identified by polymerase chain reaction using specific primers. A total of 57 patients were studied, of whom 79.1% were aged jugal mucosa, and more frequently, the tongue. HPV 13 was found in all the patients and HPV 32 in none. A total of 42 saliva samples were positive for HPV 13. Human papillomavirus type 13 is involved in multifocal epithelial hyperplasia among the Mexican Mayan population. The presence of HPV 13 in cells from saliva, combined with poor hygiene behaviors, may explain the familial distribution of the pathology. © 2011 The International Society of Dermatology.

  18. Multifocal fibrosclerosis and IgG4-related disease involving the cardiovascular system

    International Nuclear Information System (INIS)

    Ishizaka, Nobukazu; Terasaki, Fumio; Sakamoto, Aiko; Imai, Yasushi; Nagai, Ryozo

    2012-01-01

    The cardiovascular system may be involved as a target organ of multifocal fibrosclerosis, which may manifest as idiopathic retroperitoneal fibrosis, inflammatory aortic aneurysm, inflammatory periarteritis, and inflammatory pericarditis. These pathological conditions can sometimes occur concomitantly. Idiopathic retroperitoneal fibrosis and inflammatory abdominal aortic aneurysm are both characterized by the presence of fibro-inflammatory tissue around the abdominal aorta expanding into the surrounding retroperitoneal structures, and together they may be termed 'chronic periaortitis'. Cardiovascular fibrosclerosis has become non-uncommonly encountered condition since imaging modalities have made its diagnosis more feasible. In addition, recent studies have demonstrated that a certain fraction, but not all, of cardiovascular fibrosclerosis may have a link with immunoglobulin-G4 (IgG4)-related sclerosing disease (IgG4-SD). IgG4-SD is histologically characterized by dense fibrosclerosis and infiltration of lymphocytes and IgG4-positive plasma cells, and these histopathologic findings seem to be essentially similar regardless of the organs involved. In this mini review, we summarize what is known so far about multifocal fibrosclerosis of the cardiovascular system and its association with IgG4-SD, and what remains to be clarified in future investigations. (author)

  19. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children.

    Directory of Open Access Journals (Sweden)

    Martina Brandner

    Full Text Available To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population.Retrospective study.Ten consecutive pediatric patients (15 eyes underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed.Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident.Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate.

  20. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children

    Science.gov (United States)

    Brandner, Martina; Thaler-Saliba, Sarah; Plainer, Sophie; Vidic, Bertram; El-Shabrawi, Yosuf; Ardjomand, Navid

    2015-01-01

    Purpose To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population. Design Retrospective study. Patients and Methods Ten consecutive pediatric patients (15 eyes) underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed. Results Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident. Conclusion Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate. PMID:26110864

  1. Anti-tubercular therapy for intraocular tuberculosis: A systematic review and meta-analysis.

    Science.gov (United States)

    Kee, Ae Ra; Gonzalez-Lopez, Julio J; Al-Hity, Aws; Gupta, Bhaskar; Lee, Cecilia S; Gunasekeran, Dinesh Visva; Jayabalan, Nirmal; Grant, Robert; Kon, Onn Min; Gupta, Vishali; Westcott, Mark; Pavesio, Carlos; Agrawal, Rupesh

    2016-01-01

    Intraocular tuberculosis remains a diagnostic and management conundrum for both ophthalmologists and pulmonologists. We analyze the efficacy and safety of anti-tubercular therapy (ATT) in patients with intraocular tuberculosis and factors associated with favorable outcome. Twenty-eight studies are included in this review, with a total of 1,917 patients. Nonrecurrence of inflammation was observed in pooled estimate of 84% of ATT-treated patients (95% CI 79-89). There was minimal difference in the outcome between patients treated with ATT alone (85% successful outcome; 95% CI 25-100) and those with concomitant systemic corticosteroid (82%; 95% CI 73-90). The use of ATT may be of benefit to patients with suspected intraocular tuberculosis; however, this conclusion is limited by the lack of control group analysis and standardized recruitment and treatment protocols. We propose further prospective studies to better establish the efficacy of ATT and ascertain the factors associated with favorable treatment outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Intraocular pressure menagement with transpalpebral tonometry

    OpenAIRE

    Toker, Mustafa İlker; Dursun, Ayhan

    2013-01-01

    Applanation tonometry is the method of measuring intraocular pressure (IOP) with instruments the corneal surface. The Goldmann applanation tonometer (GAT) is regarded as the “gold standard’’ of measuring IOP. An irregular and opaque corneal surface compromises IOP measurement by Goldmann applanation tonometry. In such cases accurate measurement without corneal contact would be applicable. The transpalpebral tonometer is new method and measures IOP without corneal contact through the eyelid....

  3. Liquid-crystal intraocular adaptive lens with wireless control

    NARCIS (Netherlands)

    Simonov, A.N.; Vdovine, G.V.; Loktev, M.

    2007-01-01

    We present a prototype of an adaptive intraocular lens based on a modal liquid-crystal spatial phase modulator with wireless control. The modal corrector consists of a nematic liquid-crystal layer sandwiched between two glass substrates with transparent low- and high-ohmic electrodes, respectively.

  4. Clinical analysis of modified trabeculectomy in glaucoma surgery with high elevated intraocular pressure

    Directory of Open Access Journals (Sweden)

    Cang-Xia Zhang

    2013-10-01

    Full Text Available AIM: To make a retrospective analysis of the clinical data of modified trabeculectomy in treating glaucoma surgery with high elevated intraocular pressure retrospectively and evaluate the effect of modified trabeculectomy.METHODS:One hundred acute angle-closure glaucoma patients(100 eyeswith persistent high intraocular pressure were divided into treatment group(45 eyesand control group(55 eyes. Patients in treatment group was treated with by trabeculectomy, while those in control group received modified trabeculectomy. The modified measures include stellate ganglion block preoperative, topical anesthesia and local anesthesia with 20g/L lidocaine cotton-piece, to make scleral flap with sclerotome, to release aqueous humor outflow slowly after paracentesis of anterior chamber, and using mydriatic and cycloplegic during and after surgery.RESULTS: The incidence of operation complicationin control group was lower than that in treatment group. The differences were statistically significant(Pt=9.1535, Pt=39.8010, Pt=11.3219, PCONCLUSION: The modified trabeculectomy applied in the treatment of glaucoma with persistent high intraocular pressure can not only save the visual function of connection part to a certain extent, but also reduce the incidence of serious complications. It can obtain better intraocular pressure, shorten the average hospitalization days, decrease the expenses and increase patients satisfaction.

  5. Progressive multifocal leukoencephalopathy limited to the brain stem

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, O.; Maschke, M.; Diener, H.C. [Neurologische Universitaetsklinik, University of Essen (Germany); Wanke, I. [Department of Neuroradiology, University of Essen (Germany)

    2002-03-01

    Progressive multifocal leukoencephalopathy (PML) is a subacute demyelinating slow-virus encephalitis caused by the JC polyomavirus in 2-5% of patients with AIDS. MRI typically shows multiple lesions in the cerebral hemispheres. We present a rare case of rapidly evolving and lethal PML with a severe bulbar syndrome and spastic tetraparesis in a patient with AIDS. MRI showed high-signal lesions on T2-weighted images confined to the brain stem, extending from the medulla oblongata to the midbrain. JC virus polymerase chain reaction in cerebrospinal fluid was positive, and neuropathology showed the findings of PML. This case was also notable because of the rapid progression despite improved immune status with antiretroviral therapy. (orig.)

  6. Early Magnetic Resonance Detection of Natalizumab-Related Progressive Multifocal Leukoencephalopathy in a Patient with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Guglielmo Manenti

    2013-01-01

    Full Text Available Diagnosis of progressive multifocal leukoencephalopathy is usually based on the clinical presentation, on the demonstration of the brain lesions at the magnetic resonance imaging examination, and on the detection of the JC virus DNA in the cerebrospinal fluid with high sensitive polymerase chain reaction. The role of magnetic resonance imaging specifically in natalizumab-associated progressive multifocal leukoencephalopathy is strengthening, and it is gaining importance not only as an irreplaceable diagnostic tool but also as a surveillance and risk stratifying tool in treated patients. While other imaging techniques such as computed tomography lack sensitivity and specificity, magnetic resonance performed with morphological and functional sequences offers clinicians the possibility to early identify the stage of the disease and the emergence of an immune reconstitution inflammatory syndrome after natalizumab blood removal plasmapheresis.

  7. The value of local treatment in patients with primary, disseminated, multifocal Ewing sarcoma (PDMES)

    NARCIS (Netherlands)

    Haeusler, Julia; Ranft, Andreas; Boelling, Tobias; Gosheger, Georg; Braun-Munzinger, Gabriele; Vieth, Volker; Burdach, Stefan; van den Berg, Henk; Juergens, Heribert; Dirksen, Uta

    2010-01-01

    The value of local treatment in patients with primary, disseminated, multifocal Ewing sarcoma (PDMES) was investigated. We analyzed 120 patients registered into the European Ewing Tumor Working Initiative of National Groups (EURO-E.W.I.N.G. 99) trial at the trial center of Muenster from 1998 to

  8. Changes in intraocular pressure and horizontal pupil diameter ...

    African Journals Online (AJOL)

    The objective of this study was to determine the effects of topical 0.5% tropicamide, 1% atropine sulphate and 10% phenylephrine hydrochloride ophthalmic solutions on intraocular pressure (IOP) and horizontal pupil diameter (HPD) in the dog during the first hour after treatment. Forty clinically and ophthalmologically ...

  9. Visual outcome with the Oculentis Mplus intraocular lens

    Directory of Open Access Journals (Sweden)

    Si-Yuan Liu

    2017-11-01

    Full Text Available AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL.METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOLwere as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications. RESULTS: At 3mo after surgery, distance visual acuity of test group with Oculentis Mplus IOL were 0.10±0.03,the difference with control group was not significant(t=1.74, P>0.05. Eyes in test group had an uncorrected near acuity 0.11±0.04, the difference with control group was significant(t=15.53, PCONCLUSION: The implantation of Oculentis Mplus IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. The surgery is safe, reliable and no special complication induced.

  10. An ultralow power wireless intraocular pressure monitoring system

    International Nuclear Information System (INIS)

    Liu Demeng; Mei Niansong; Zhang Zhaofeng

    2014-01-01

    This paper describes an ultralow power wireless intraocular pressure (IOP) monitoring system that is dedicated to sensing and transferring intraocular pressure of glaucoma patients. Our system is comprised of a capacitive pressure sensor, an application-specific integrated circuit, which is designed on the SMIC 180 nm process, and a dipole antenna. The system is wirelessly powered and demonstrates a power consumption of 7.56 μW at 1.24 V during continuous monitoring, a significant reduction in active power dissipation compared to existing work. The input RF sensitivity is −13 dBm. A significant reduction in input RF sensitivity results from the reduction of mismatch time of the ASK modulation caused by FM0 encoding. The system exhibits an average error of ± 1.5 mmHg in measured pressure. Finally, a complete IOP system is demonstrated in the real biological environment, showing a successful reading of the pressure of an eye. (semiconductor integrated circuits)

  11. INTRAOCULAR AND SERUM LEVELS OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN ACUTE RETINAL NECROSIS AND OCULAR TOXOPLASMOSIS

    NARCIS (Netherlands)

    Wiertz, Karin; De Visser, Lenneke; Rijkers, Ger; De Groot-Mijnes, Jolanda; Los, Leonie; Rothova, Aniki

    2010-01-01

    Purpose: To determine the intraocular and serum vascular endothelial growth factor (VEGF) levels in patients with acute retinal necrosis (ARN) and compare those with VEGF levels found in patients with ocular toxoplasmosis (OT). Methods: Paired intraocular fluid and serum samples of 17 patients with

  12. Intraocular Pressure in Pregnant and Non-Pregnant Nigerian Women

    African Journals Online (AJOL)

    Erah

    . ... ocular diseases and these were used as the exclusion ... between groups with student's t-test. ... SD = standard deviation, SEM = standard error of mean, N= .... 38(4):229-34. 26. Qureshi IA. Intraocular pressure and pregnancy. Clin. Med.

  13. Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility

    OpenAIRE

    Chintalapudi, Sumana R.; Maria, Doaa; Di Wang, Xiang; Bailey, Jessica N. Cooke; Hysi, Pirro G.; Wiggs, Janey L.; Williams, Robert W.; Jablonski, Monica M.

    2017-01-01

    textabstractGlaucoma is a multi-factorial blinding disease in which genetic factors play an important role. Elevated intraocular pressure is a highly heritable risk factor for primary open angle glaucoma and currently the only target for glaucoma therapy. Our study helps to better understand underlying genetic and molecular mechanisms that regulate intraocular pressure, and identifies a new candidate gene, Cacna2d1, that modulates intraocular pressure and a promising therapeutic, pregabalin, ...

  14. Strategy in Regulatory Decision-Making for Management of Progressive Multifocal Leukoencephalopathy

    DEFF Research Database (Denmark)

    Segec, A; Keller-Stanislawski, B; Vermeer, N S

    2015-01-01

    Progressive multifocal leukoencephalopathy (PML) has been observed after the use of several medicines, including monoclonal antibodies. As these drugs play important roles in the therapeutic armamentarium, it is important to address the challenges that this severe adverse reaction poses to the safe...... use of medicines. Considering the need for consistent outcomes of regulatory decisions, the European Medicines Agency Pharmacovigilance Risk Assessment Committee (PRAC) used PML as an example to develop a systematic approach to labeling and risk minimization....

  15. Cambios de la presión intraocular en pacientes con hipertensión arterial

    Directory of Open Access Journals (Sweden)

    G. Tenorio-Guajardo

    2014-07-01

    Conclusiones: En este estudio se encontró correlación entre presión intraocular y la presión arterial diastólica, pero no se encontró correlación entre la sistólica. Es recomendable vigilar la presión intraocular en pacientes hipertensos, especialmente en aquellos con hipertensión diastólica persistente y con antecedentes familiares de glaucoma.

  16. Photodynamic therapy of intraocular cancers

    International Nuclear Information System (INIS)

    Gravier, N.; Duvournau, Y.; Querec, M.A.; Pechereau, A.; Patrice, T.

    1992-01-01

    The most common intraocular tumors are choroidal malignant melanomas (70%) and retinoblastomas (13%). Each time that visual acuity is preserved, various conservative treatments are considered relative to the potential risk of metastatic disease during enucleation. In addition to standard techniques, photodynamic therapy is a potentially attractive new approach limited in its effects to the area of the treated tumor. The purpose of this preclinical study is to determine a reference dose-effect for single laser doses and to study effects of fractionation of the laser dose. (author). 9 refs., 1 tab

  17. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  18. Intraocular pressure-lowering effect of oral paracetamol and its in vitro corneal penetration properties

    Directory of Open Access Journals (Sweden)

    Mohamed N

    2013-01-01

    Full Text Available Nabiel Mohamed, David MeyerDivision of Ophthalmology, Faculty of Medicine and Health Sciences, University of Stellenbosch, Cape Town, South AfricaBackground: Several studies have confirmed the ability of cannabinoids to reduce intraocular pressure. Experimental data recently demonstrated unequivocally that the analgesic effect of paracetamol is due to its indirect action on cannabinoid receptors. The question then arises as to whether paracetamol can reduce intraocular pressure via its effect on intraocular cannabinoid receptors.Methods: A 2-week, prospective, randomized, controlled, single-center, parallel-group pilot study was carried out to determine the efficacy and safety of paracetamol 1 g orally administered every 6 hours in adult patients with primary or secondary open angle glaucoma as compared with topical levobunolol 0.5% twice a day. Patient well-being was closely monitored throughout the study and focused on hepatic safety in accordance with Drug-Induced Liver Injury Network criteria. The in vitro diffusion kinetics of acetaminophen in a phosphate-buffered solution in rabbit and human corneas was also investigated, with the view to a topical application.Results: Eighteen adult patients were enrolled in the study, with nine in the topical levobunolol group and nine in the oral paracetamol group. In the levobunolol group, the mean reduction in intraocular pressure at day 7 was 7.5 mmHg (P < 0.008 and at day 14 was 9.1 mmHg (P < 0.005, from a mean baseline intraocular pressure of 29.6 mmHg. The corresponding figures for the paracetamol group were 8.8 mmHg (P < 0.0004 at day 7 and 6.5 mmHg (P < 0.004 at day 14, from a mean baseline intraocular pressure of 29.4 mmHg. Both study regimens were well tolerated. No serious treatment-related adverse events were reported in either of the treatment groups. Liver function tests, systolic/diastolic blood pressure, or heart rate remained unchanged in both groups during the 2 weeks of the study. In

  19. Bartonella and intraocular inflammation: a series of cases and review of literature

    Directory of Open Access Journals (Sweden)

    Kalogeropoulos C

    2011-06-01

    Full Text Available Chris Kalogeropoulos1, Ioannis Koumpoulis1, Andreas Mentis2, Chrisavgi Pappa1, Paraskevas Zafeiropoulos1, Miltiadis Aspiotis11Department of Ophthalmology, Medical School, University of Ioannina, Greece; 2Laboratory of Medical Microbiology, Hellenic Pasteur Institute, Athens, GreecePurpose: To present various forms of uveitis and/or retinal vasculitis attributed to Bartonella infection and review the impact of this microorganism in patients with uveitis.Methods: Retrospective case series study. Review of clinical records of patients diagnosed with Bartonella henselae and Bartonella quintana intraocular inflammation from 2001 to 2010 in the Ocular Inflammation Department of the University Eye Clinic, Ioannina, Greece. Presentation of epidemiological and clinical data concerning Bartonella infection was provided by the international literature.Results: Eight patients with the diagnosis of Bartonella henselae and two patients with B. quintana intraocular inflammation were identified. Since four patients experienced bilateral involvement, the affected eyes totaled 14. The mean age was 36.6 years (range 12–62. Uveitic clinical entities that we found included intermediate uveitis in seven eyes (50%, vitritis in two eyes (14.2%, neuroretinitis in one eye (7.1%, focal retinochoroiditis in one eye (7.1%, branch retinal vein occlusion (BRVO due to vasculitis in one eye (7.1%, disc edema with peripapillary serous retinal detachment in one eye (7.1%, and iridocyclitis in one eye (7.1%. Most of the patients (70% did not experience systemic symptoms preceding the intraocular inflammation. Antimicrobial treatment was efficient in all cases with the exception of the case with neuroretinitis complicated by anterior ischemic optic neuropathy and tubulointerstitial nephritis.Conclusion: Intraocular involvement caused not only by B. henselae but also by B. quintana is being diagnosed with increasing frequency. A high index of suspicion is needed because the

  20. The spatial resolution of the porcine multifocal electroretinogram for detection of laser-induced retinal lesions

    DEFF Research Database (Denmark)

    Kyhn, Maria Voss; Kiilgaard, Jens Folke; Scherfig, Erik

    2008-01-01

    This study aimed to investigate the spatial resolution of a porcine multifocal electroretinogram (mfERG) protocol by testing its ability to detect laser-induced retinal lesions. Furthermore, we wanted to describe time-dependent changes in implicit time and amplitude of the different mfERG peaks...

  1. Paracoccidioidomicose crônica multifocal tendo como primeira manifestação o envolvimento palpebral: relato de caso Chronical and multifocal paracoccidioidomycosis having the lid involvement as the first sign: case report

    Directory of Open Access Journals (Sweden)

    Tiago Nelson de Oliveira Rassi

    2009-12-01

    Full Text Available O acometimento ocular da paracoccidioidomicose é raro e quando ocorre é geralmente secundário à disseminação hematogênica. Descrição de um caso de paracococcidioidomicose multifocal em homem de 73 anos com história de trauma contuso no olho direito por pedaço de madeira e que teve como primeira manifestação clínica lesão palpebro-conjuntival. Interroga-se possível infecção primária ocular por contiguidade e alerta-se para a manifestação da doença em idade mais avançada.Ocular involvement of paracoccidioidomycosis is rare and when it occurs it is usually secondary to hematogenic dissemination. A case of multifocal paracoccidioidomycosis in a 73 year-old male after history of blunt trauma in the right eye with a stick of wood that presented as the first clinical sign a lid-conjunctival lesion is described. The possible primary ocular infection spreading by contiguity is argued and the disease manifestation in an advanced age is highlighted.

  2. Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility.

    Science.gov (United States)

    Chintalapudi, Sumana R; Maria, Doaa; Di Wang, Xiang; Bailey, Jessica N Cooke; Hysi, Pirro G; Wiggs, Janey L; Williams, Robert W; Jablonski, Monica M

    2017-11-24

    Glaucoma is a multi-factorial blinding disease in which genetic factors play an important role. Elevated intraocular pressure is a highly heritable risk factor for primary open angle glaucoma and currently the only target for glaucoma therapy. Our study helps to better understand underlying genetic and molecular mechanisms that regulate intraocular pressure, and identifies a new candidate gene, Cacna2d1, that modulates intraocular pressure and a promising therapeutic, pregabalin, which binds to CACNA2D1 protein and lowers intraocular pressure significantly. Because our study utilizes a genetically diverse population of mice with known sequence variants, we are able to determine that the intraocular pressure-lowering effect of pregabalin is dependent on the Cacna2d1 haplotype. Using human genome-wide association study (GWAS) data, evidence for association of a CACNA2D1 single-nucleotide polymorphism and primary open angle glaucoma is found. Importantly, these results demonstrate that our systems genetics approach represents an efficient method to identify genetic variation that can guide the selection of therapeutic targets.

  3. Multifocal osteolysis following limb-sparing procedures: imaging findings and a review of the literature

    International Nuclear Information System (INIS)

    Kaste, S.C.; Rao, B.N.; Lynch, M.H.; Parham, D.M.; Meyer, W.H.

    1996-01-01

    Limb-sparing procedures utilizing endoprostheses improve both the quality of life and functional level of patients treated for primary bone sarcomas. Herein, we present the imaging findings of an uncommon cause of prosthetic failure, i. e., foreign body reaction, manifested by progressive multifocal osteolysis along the prosthetic femoral shaft. (orig.). With 3 figs

  4. Preventing falls in older multifocal glasses wearers by providing single-lens distance glasses: the protocol for the VISIBLE randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Lee Bonsan B

    2009-03-01

    Full Text Available Abstract Background Recent research has shown that wearing multifocal glasses increases the risk of trips and falls in older people. The aim of this study is to determine whether the provision of single-lens distance glasses to older multifocal glasses wearers, with recommendations for wearing them for walking and outdoor activities, can prevent falls. We will also measure the effect of the intervention on health status, lifestyle activities and fear of falling, as well as the extent of adherence to the program. Methods/Design Approximately 580 older people who are regular wearers of multifocal glasses people will be recruited. Participants will be randomly allocated to either an intervention group (provision of single lens glasses, with counselling and advice about appropriate use or a control group (usual care. The primary outcome measure will be falls (measured with 13 monthly calendars. Secondary measures will be quality of life, falls efficacy, physical activity levels and adverse events. Discussions The study will determine the impact of providing single-lens glasses, with advice about appropriate use, on preventing falls in older regular wearers of multifocal glasses. This pragmatic intervention, if found to be effective, will guide practitioners with regard to recommending appropriate glasses for minimising the risk of falls in older people. Trial Registration The protocol for this study was registered with the Clinical Trials.gov Protocol Registration System on June 7th 2006 (#350855.

  5. The Effects of Hashimoto Thyroiditis on Lymph Node Metastases in Unifocal and Multifocal Papillary Thyroid Carcinoma: A Retrospective Chinese Cohort Study.

    Science.gov (United States)

    Zhu, Feng; Shen, Yi Bin; Li, Fu Qiang; Fang, Yun; Hu, Liang; Wu, Yi Jun

    2016-02-01

    The purpose of this study was to investigate the risk factors for central and lateral neck lymph node metastases in papillary thyroid carcinoma (PTC) and multifocal papillary thyroid carcinoma (MPTC), particularly when associated with Hashimoto thyroiditis (HT).A retrospective analysis of 763 consecutive patients who underwent total thyroidectomy with bilateral central neck dissection in the First Affiliated Hospital, College of Medicine, Zhejiang University between October 2011 and October 2014 was conducted. All patients had formal histological diagnoses of HT. Multivariable logistic regression analysis was performed to identify risk factors of neck lymph node metastases.Our study identified 277 PTC patients with HT and showed comparatively low rates of central lymph node metastases (CLNM) compared with the PTC patients without HT (37.2% versus 54.7%, P thyroid peroxidase antibody >140 IU/mL was established as the most sensitive and specific level for the prediction of MPTC based on receiver operating characteristic curve analyses. Thyroid peroxidase antibody, age, tumor size, and multifocality exhibited the ability to predict CLNM in PTC with HT patients with an area under the curve of 81.1% based on a multivariate model.Hashimoto thyroiditis was associated with increased prevalences of multifocality and capsular invasion. In contrast, HT was associated with a reduced risk of CLNM in PTC and MPTC patients, which indicated a potential protective effect. We found that the prognostic prediction model was applicable for predicting multifocality and CLNM in PTC patients with HT.

  6. Lente intra-ocular opaca em diplopia intratável: relato de caso Opaque intraocular lens in intractable diplopia: case report

    Directory of Open Access Journals (Sweden)

    Fernanda Teixeira Krieger

    2006-08-01

    Full Text Available Diplopia intratável tem sido descrita em várias situações. Métodos convencionais como prismas e correção cirúrgica do estrabismo falham em neutralizá-la. O objetivo do trabalho é documentar o caso de uma paciente com estrabismo de longa data, cuja diplopia deteriorou-se ao longo dos anos, e não foi possível resolução com cirurgia, prisma, e oclusão com óculos e lente de contato com pupila opaca. A paciente foi então submetida à facoemulsificação com implante de lente intra-ocular opaca que atingiu o objetivo desejado.Intractable diplopia has been described in many situations but poor results are the rule with standard treatment modalities. The authors report a case of a woman with long-standing strabismus and diplopia who failed to improve following surgery, prism, and occlusive spectacles or contact lenses. Then, she was submitted to phacoemulsification and opaque intraocular lens implantation, which successfully neutralized diplopia.

  7. Chimeric immune receptors (CIRs) specific to JC virus for immunotherapy in progressive multifocal leukoencephalopathy (PML)

    NARCIS (Netherlands)

    W. Yang; E.L. Beaudoin; L. Lu; R.A. Du Pasquier (Renaud); M.J. Kuroda; R.A. Willemsen (Ralph); I.J. Koralnik; R.P. Junghans

    2007-01-01

    textabstractProgressive multifocal leukoencephalopathy (PML) is a deadly brain disease caused by the polyomavirus JC (JCV). The aim of this study is to develop 'designer T cells' armed with anti-JCV TCR-based chimeric immune receptors (CIRs) by gene modification for PML immunotherapy. Two T cell

  8. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  9. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  10. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  11. Comparison of T stage, N stage, multifocality, and bilaterality in papillary thyroid carcinoma patients according to the presence of coexisting lymphocytic thyroiditis.

    Science.gov (United States)

    Park, Jin Young; Kim, Dong Wook; Park, Ha Kyung; Ha, Tae Kwun; Jung, Soo Jin; Kim, Do Hun; Bae, Sang Kyun

    2015-01-01

    This study aimed to assess the relationship between coexisting lymphocytic thyroiditis and T-N stages of papillary thyroid carcinoma (PTC) by histopathological analysis. The study included 653 patients who underwent thyroid surgery for PTC at our hospital. Each case was classified as either Hashimoto's thyroiditis (HT), non-Hashimoto type of lymphocytic thyroiditis (NHLT), or normal according to the histopathology of thyroid parenchyma. Patient age, gender, surgical modality, location, T stage, N stage, multifocality and bilaterality were compared according to the histopathology. The prevalence of coexisting lymphocytic thyroiditis was 25.8% (169/653); HT (7.5%, 49/653) and NHLT (18.3%, 120/653). There were no significant differences in T stage, N stage, multifocality and bilaterality with regard to coexisting lymphocytic thyroiditis, regardless of whether HT and NHLT were considered collectively or discretely. Primary tumor size (p thyroiditis did not differ from those with normal parenchyma in terms of T stage, N stage, multifocality and bilaterality.

  12. Cerebral migration of intraocular silicone oil: an MRI study

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Milea, Dan; Løgager, Vibeke

    2011-01-01

    for retinal detachment. Methods: Nineteen patients included in this study were referred for silicone oil removal after uncomplicated retinal detachment surgery using internal silicone oil tamponade. Patients with a previous history of intraocular silicone oil, glaucoma or optic pit were excluded. After...

  13. Locally aggressive and multifocal phosphaturic mesenchymal tumors: two unusual cases of tumor-induced osteomalacia.

    Science.gov (United States)

    Higley, Meghan; Beckett, Brooke; Schmahmann, Sandra; Dacey, Elizabeth; Foss, Erik

    2015-12-01

    Tumor-induced osteomalacia (TIO) has long been recognized as a clinical paraneoplastic syndrome. The identification of a unique histopathologic entity, the phosphaturic mesenchymal tumor (PMT), as a distinct etiology for TIO has been a more recent discovery. The majority of published cases describe a solitary, non-aggressive appearing soft tissue or osseous lesions in patients with osteomalacia; aggressive appearing or multifocal lesions appear to be exceedingly rare. These tumors characteristically secrete fibroblast growth factor 23 (FGF23). Elevated serum levels of FGF23 result in phosphate wasting and osteomalacia. In the majority of cases, laboratory abnormalities and clinical signs and symptoms of osteomalacia precede identification of the causative lesion by years. Following diagnosis, complete resection with wide margins to prevent local recurrence is most often curative. Imaging characteristics of PMT are diverse and remain incompletely defined, as the majority of previous publications are outside of the radiologic literature. We present multiple imaging modalities in two cases of patients with debilitating osteomalacia and unusual appearing PMTs: one with a locally aggressive lesion leading to pathologic fracture, the second presenting with exceedingly rare multifocal PMT.

  14. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

    Science.gov (United States)

    Vincent, Stephen J; Vincent, Roslyn A; Shields, David; Lee, Graham A

    2012-01-01

    To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. One hundred nine (54 males : 55 females) patients including only eyes under medical treatment for glaucoma. Measurement by Goldmann applanation tonometry, iCare rebound tonometry and 7CR non-contact tonometry. Intraocular pressure. There were strong correlations between the intraocular pressure measurements obtained with Goldmann and both the rebound and non-contact tonometers (Spearman r-values ≥ 0.79, P tonometer. For the rebound tonometer, the mean intraocular pressure was slightly higher compared with the Goldmann applanation tonometer in the right eyes (P = 0.02), and similar in the left eyes (P = 0.93); however, these differences did not reach statistical significance. The Goldmann correlated measurements from the non-contact tonometer were lower than the average Goldmann reading for both right (P 0.01) eyes. The corneal compensated measurements from the non-contact tonometer were significantly higher compared with the other tonometers (P ≤ 0.001). The iCare rebound tonometer and the 7CR non-contact tonometer measure intraocular pressure in fundamentally different ways to the Goldmann applanation tonometer. The resulting intraocular pressure values vary between the instruments and will need to be considered when comparing clinical versus home acquired measurements. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  15. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  16. [Contemporary possibilities of intraocular pressure measurement].

    Science.gov (United States)

    Hornová, J; Baxant, A

    2013-10-01

    Authors introduced current possibilities of measuring intraocular pressure (IOP). A list of available methods of monitoring IOP is published; contact measurement method IOP directly on the cornea, but also over upper lid, methodology of minimal contact and non-contact measurement. Following contact methods are described; former measurements of IOP by impression Schiotz tonometer and the current methodology applanation. So far as the gold standard measurement Goldmann applanation tonometer (GAT) is considered, another methodology with applanation measurements are compared: Pascal dynamic contoured tonometer (DCT ), BioResonator - resonant applanation tonometer (ART ), digital applanation tonometer Tonopen and last hit: continuous measurement of IOP by Sensimed Triggerfish. Orientation and rapid assessment is palpation pressure control over the lid and measuring by tonometer Diaton. Rebound tonometer (RBT) iCare belongs to measurements with minimal contact, no need anesthetic drops and fluorescein, therefore a self - home version of IOP measurements (Icare ONE) is developed. Non-contact measurement of IOP by different pneumotonometers is popular for screening assessment of IOP. Reichert Ocular Response Analyzer (ORA) is a non-contact applanation IOP measurement and reveals additional properties of the cornea. In the discussion of a range methodology is evaluated, the experience of other authors and their own experience is compared. For monitoring of patients is necessary to select the most suitable methodology, measure repeatedly and accurately to allow long-term monitoring of intraocular pressure.

  17. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    Science.gov (United States)

    Sinha, D.N.; Wray, W.O.

    1994-12-27

    The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.

  18. A STUDY OF CASE SERIES OF INTRAOCULAR FOREIGN BODIES IN A TERTIARY CARE CENTER IN SOUTH INDIA

    Directory of Open Access Journals (Sweden)

    Shilpa Y. D

    2017-09-01

    Full Text Available BACKGROUND Intraocular foreign bodies can cause vision threatening complication in cases of penetrating ocular injuries. Ocular injuries can occur anywhere at work place, at home, due to road traffic accidents, etc. Accidental eye injuries are common in males in work place. Awareness about using protective eye wear is required at work places where injuries are common. The aim of the study is to study the demographic profile, visual and anatomical outcome in patients presenting with posterior segment Intraocular Foreign Bodies (IOFB undergoing vitrectomy. MATERIALS AND METHODS Retrospective analysis was done on patients who underwent pars plana vitrectomy for posterior segment IOFB from March 2014 to April 2017. Complete ocular examination, B scan ultrasonography and x-ray orbit were done in all cases and retained posterior segment intraocular foreign body confirmed. Intraoperative difficulties, anatomical and visual outcome and postoperative complications were studied. RESULTS Cases with posterior segment intraocular foreign body and endophthalmitis had poor visual and anatomical outcome. Patients who underwent complete vitrectomy with 240 encirclage band with or without tamponade had better visual outcome. CONCLUSION Imaging in the injured eye is important to identify the presence of intraocular foreign body. Planning of the surgical procedure depending on the ocular condition plays a vital role in visual outcome.

  19. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  20. Bacterial contamination of intraocular lens surgery.

    OpenAIRE

    Vafidis, G C; Marsh, R J; Stacey, A R

    1984-01-01

    One hundred sterile intraocular lenses were placed on the external eye of 50 patients during cataract surgery. Half of the specimens were cultured for bacteria, the other half were examined under the light microscope after fixing and staining. A bacterial contamination rate of 26% was recorded. This is significantly higher than that found in conjunctival swabs (6%) or irrigation specimens (8%) taken at the same time, and higher than that recorded in a group of control lenses (15.2%) exposed t...

  1. Imaging of chronic recurrent multifocal osteomyelitis of childhood first presenting with isolated primary spinal involvement

    International Nuclear Information System (INIS)

    Anderson, S.E.; Heini, P.; Kalbermatten, D.; Sauvain, M.J.; Stauffer, E.; Geiger, L.; Johnston, J.O.; Roggo, A.; Steinbach, L.S.

    2003-01-01

    Initial presentation with primary spinal involvement in chronic recurrent multifocal osteomyelitis of childhood (CRMO) is rare. Our objective was to review the imaging appearances of three patients who had CRMO who initially presented with isolated primary spinal involvement.Design and patients The imaging, clinical, laboratory and histology findings of the three patients were retrospectively reviewed. Imaging included seven spinal MR imaging scans, one computed tomography scan, nine bone scans, two tomograms and 16 radiographs. These were reviewed by two musculoskeletal radiologists and a consensus view is reported. All three patients presented with atraumatic spinal pain and had extensive bone spinal pathology. The patients were aged 11, 13 and 12 years. There were two females and one male.Results and conclusions The initial patient had thoracic T6 and T8 vertebra plana. Bone scan showed additional vertebral body involvement. Follow-up was available over a 3 year period. The second patient had partial collapse of T9 and, 2 years later, of C6. Subsequently extensive multifocal disease ensued and follow-up was available over 8 years. The third patient initially had L3 inferior partial collapse and 1 year later T8 involvement with multifocal disease. Follow-up was available over 3 years. The imaging findings of the three patients include partial and complete vertebra plana with a subchondral line adjacent to endplates associated with bone marrow MR signal alterations. Awareness of the imaging appearances may help the radiologist to include this entity in the differential diagnosis in children who present with spinal pathology and no history of trauma. Histopathological examination excludes tumor and infection but with typical imaging findings may not always be necessary. (orig.)

  2. MRI shows thickening and altered diffusion in the median and ulnar nerves in multifocal motor neuropathy

    DEFF Research Database (Denmark)

    Haakma, Wieke; Jongbloed, Bas A.; Froeling, Martijn

    2017-01-01

    Objectives To study disease mechanisms in multifocal motor neuropathy (MMN) with magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) of the median and ulnar nerves. Methods We enrolled ten MMN patients, ten patients with amyotrophic lateral sclerosis (ALS) and ten healthy controls...

  3. Strategy in Regulatory Decision-Making for Management of Progressive Multifocal Leukoencephalopathy.

    Science.gov (United States)

    Segec, A; Keller-Stanislawski, B; Vermeer, N S; Macchiarulo, C; Straus, S M; Hidalgo-Simon, A; De Bruin, M L

    2015-11-01

    Progressive multifocal leukoencephalopathy (PML) has been observed after the use of several medicines, including monoclonal antibodies. As these drugs play important roles in the therapeutic armamentarium, it is important to address the challenges that this severe adverse reaction poses to the safe use of medicines. Considering the need for consistent outcomes of regulatory decisions, the European Medicines Agency Pharmacovigilance Risk Assessment Committee (PRAC) used PML as an example to develop a systematic approach to labeling and risk minimization. © 2015 American Society for Clinical Pharmacology and Therapeutics.

  4. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    OpenAIRE

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, ...

  5. A role for susceptibility weighted imaging in progressive multifocal leukoencephalopathy

    LENUS (Irish Health Repository)

    Yap, SM

    2017-04-01

    We report a radiologic finding on magnetic resonance imaging (MRI) of the brain of two cases of progressive multifocal leukoencephalopathy (PML) of hypointense signal of subcortical U-fibres on susceptibility weighted (SW) sequence. The first case is a 50-year-old man recently treated with chemotherapy including rituximab for non-Hodgkin\\'s lymphoma. The second case is a 64-year-old woman with human immunodeficiency virus (HIV) infection. Iron deposition is a likely causative factor. We propose that SWI may be especially useful in the assessment of indeterminate cases to reduce the likelihood of a missed diagnosis of PML

  6. Comparative study of intraocular pressure (IP in Bangladeshi individuals by contact and non contact technique

    Directory of Open Access Journals (Sweden)

    Sayed Abdul Wadud

    2016-07-01

    Full Text Available Background: Intraocular pressure (IOP is one of the most important parameters in the diagnosis and treatment of glaucoma. Glaucoma has been established as the second leading cause of blindness. The treatment of glaucoma focuses mainly on lowering intraocular pressure (IOP. The target IOP is often set to a level 20% to 30% of IOP reduction, and consequent large IOP reduction beyond 30% or even 40% in cases of advanced glaucoma The different methods of tonometery are: Goldman Applanation tonometery, Noncontact (air-puff tonometery, Perkins tonometery, Tonopen tonometery, Transpalpebral tonometery.Objective: To determine the frequency of accuracy of intraocular pressure (IOP measured by non-contact (air puff tonometer compared with Goldmann applanation tonometer.Methods: This was a non-interventional, cross sectional study conducted at a tertiary care centre of Dhaka, Bangladesh. consecutive subjects attending the BSMMU eye OPD were included in the study. IOP was measured by non-contact (air puff tonometer and a slit lamp mounted GAT in all the subjects. The study samples were selected by convenience sampling who presented for check-up in the Eye Department of community ophthalmology, Bangabandhu Sheikh Mujib Medical University, Dhaka. Bangladesh. Results:A total of 120 eyes in 60 patients were studied. The mean age of the patients was 41.60 year. study population consisted of 24 (40 % men and 36 (60 % women. The mean intraocular pressure was 13.52 &13.72 mmHg for GAT, and 16.64 & 17.44 mmHg for Air puff respectively. The range of measurements by GAT was from 10 to 23 mmHg and by Air puff was 12 to 28mmHg. The difference between IOP measured by two instruments were statistically significant (p=0.000.Conclusion: Airpuff tonometer is quick, a non-contact method to measure intraocular pressure and is useful for screening purposes and postoperative case but the measurements should be confirmed with Goldmann applanation tonometer for accurate labelling

  7. Multifocal bilateral metatarsal tuberculosis: a rare presentation.

    Science.gov (United States)

    Vijay, Vipul; Sud, Alok; Mehtani, Anil

    2015-01-01

    Tuberculosis, or phthisis (consumption) as it was popularly known in the Greek era, has been endemic in Southeast Asia and Sub-Saharan Africa; however, the human immunodeficiency virus epidemic has seen the re-emergence of this disease in the areas in which it was not very commonly reported. With this, the need for understanding and treatment of rare presentations of tuberculosis has become of paramount importance to achieve the World Health Organization millennium goal of a "reversal of incidence by 2015." Foot involvement has been reported in 0.1% to 0.3% of extrapulmonary cases. Multifocal lesions have an incidence of histopathologic owing to the paucibacillary nature of the disease. Early identification and treatment with antitubercular drugs will normally result in a good cosmetic and functional result. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. PROGNOSTIC FACTORS OF POSITIVE RESULTS OF MULTIFOCAL TRUS-GUIDED VESICOURETHRAL ANASTOMOSIS BIOPSY IN PATIENTS WITH BIOCHEMICAL RECURRENCE AFTER RADICAL PROSTATECTOMY

    Directory of Open Access Journals (Sweden)

    P. D. Demeshko

    2014-07-01

    Full Text Available Purpose. To evaluate influence of clinical, biochemical and histological factors to detection rate of local recurrence following radical prostatectomy (RPE using multifocal TRUS-guided vesicourethral anastomosis (VUA biopsy.Material and methods. 59 patients with newly diagnosed biochemical recurrence (BR after RPE were included into prospective study. All of them underwent multifocal TRUS-guided VUA biopsy. Сlinical variables (serum prostate-specifi c antigen [PSA] level and PSA kinetics, time RPE-BR, Gleason grade, stage after RPE and clinical findings were evaluated. Logistic regression and receiver operating characteristic (ROC curve analyses were performed.Results. The detection rate of local prostate recurrence with TRUS-guided VUA biopsy was 45,8 % (95 % CI 33,7–58,3. At multivariate analysis only PSA level at the moment of biopsy (≤ 1,5 ng/ml vs > 1,5 ng/ml and time RPE-BR (≤ 15 months vs > 15 months were significantly associated with positive results of multifocal TRUS-guided VUA biopsy (p < 0,05.Conclusion The detection rate of local prostate recurrence with TRUS-guided VUA biopsy depends on combination of independent predictors (PSA level at the moment of biopsy and time RPE—BR.

  9. [Sentinel node biopsy in patients with multifocal and multicentric breast cancer: A 5-year follow-up].

    Science.gov (United States)

    Blanco Saiz, I; López Carballo, M T; Martínez Fernández, J; Carrión Maldonado, J; Cabrera Pereira, A; Moral Alvarez, S; Santamaría Girón, L; Cantero Cerquella, F; López Secades, A; Díaz González, D; Llaneza Folgueras, A; Aira Delgado, F J

    2014-01-01

    Sentinel lymph node biopsy (SLNB) as a staging procedure in multiple breast cancer is a controversial issue. We have aimed to evaluate the efficacy of sentinel node (SN) detection in patients with multifocal or multicentric breast cancer as well as the safety of its clinical application after a long follow-up. A prospective descriptive study was performed. Eighty-nine patients diagnosed of multiple breast cancer (73 multifocal; 16 multicentric) underwent SLNB. These patients were compared to those with unifocal neoplasia. Periareolar radiocolloid administration was performed in most of the patients. Evaluation was made at an average of 67.2 months of follow-up (32-126 months). Scintigraphic and surgical SN localization in patients with multiple breast cancer were 95.5% and 92.1%, respectively. A higher percentage of extra-axillary nodes was observed than in the unifocal group (11.7% vs 5.4%) as well as a significantly higher number of SN per patient (1.70 vs 1.38). The rate of SN localization in multicentric cancer was slightly lower than in multifocal cancer (87.5% vs 93.1%), and the finding of extra-axillary drainages was higher (20% vs 10%). Number of SN per patient was significantly higher in multicentric breast cancer (2.33 vs 1.57). No axillary relapses have been demonstrated in the follow-up in multiple breast cancer patients group. SLNB performed by periareolar injection is a reliable and accurate staging procedure of patients with multiple breast cancer, including those with multicentric processes. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  10. Intraocular surgery in a large diabetes patient population

    DEFF Research Database (Denmark)

    Ostri, Christoffer

    2014-01-01

    The prevalence of diabetes is on the increase in developed countries. Accordingly, the prevention and treatment of vision-threatening diabetic eye complications is assuming greater importance. The overall aim of this thesis is to analyse risk factors for intraocular surgery in a large diabetes po...... surgery, which can be used for preventive purposes, surgical decision-making and patient counselling....

  11. Antireflection coatings for intraocular lenses of sapphire and fianite

    Energy Technology Data Exchange (ETDEWEB)

    Babin, A.A.; Konoplev, Yu.N.; Mamaev, Yu.A. [Inst. of Applied Physics, Nizhnii Novgorod (Russian Federation)] [and others

    1995-10-01

    Broadband antireflection coatings for intraocular lenses of sapphire and fianite are calculated and implemented practically. Their residual reflectance in the liquid with a refracting index of 1.336 is below 0.2% from each face virtually over the entire visible region. 7 refs., 2 figs., 2 tabs.

  12. Straylight from glistenings in intraocular lenses : In vitro study

    NARCIS (Netherlands)

    Łabuz, Grzegorz; Reus, Nicolaas J; van den Berg, Thomas J T P

    PURPOSE: To assess light scattering from intraocular lenses (IOLs) with different numbers of laboratory-induced glistenings and create a model for predicting glistening effects on straylight. SETTING: Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands. DESIGN: Experimental study. METHODS:

  13. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis.

    Science.gov (United States)

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-11-01

    Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16-0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI = -2.39 to -0.25, P = .015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P = .208). In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

  14. Digitally switchable multi-focal lens using freeform optics.

    Science.gov (United States)

    Wang, Xuan; Qin, Yi; Hua, Hong; Lee, Yun-Han; Wu, Shin-Tson

    2018-04-16

    Optical technologies offering electrically tunable optical power have found a broad range of applications, from head-mounted displays for virtual and augmented reality applications to microscopy. In this paper, we present a novel design and prototype of a digitally switchable multi-focal lens (MFL) that offers the capability of rapidly switching the optical power of the system among multiple foci. It consists of a freeform singlet and a customized programmable optical shutter array (POSA). Time-multiplexed multiple foci can be obtained by electrically controlling the POSA to switch the light path through different segments of the freeform singlet rapidly. While this method can be applied to a broad range of imaging and display systems, we experimentally demonstrate a proof-of-concept prototype for a multi-foci imaging system.

  15. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The Brazilian experience

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Trippe, N.; Novaes, P.E.; Ferrigno, R.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, C.M.

    1996-01-01

    Purpose/Objective: To show the retrospective results of intraocular tumors, including uveal melanomas and retinoblastomas treated by exclusive brachytherapy with cobalt plaques. The goal was to keep the vision function with not compromising the chance of cure. Materials and Methods: From December 1989 to December 1993, 76 cases of intraocular tumors, being 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy through cobalt plaques. The prescribed dose was 40 Gy, calculated at the apex of the lesion for retinoblastomas and 100 Gy for melanomas. The selection criteria included those introcular lesions with diameter until 15 mm. Results: With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved with no evidence of disease, while 15 (26,4%) had local failure and were underwent to enucleation. With the medium follow up of 27 months, of the 20 patients with retinoblastoma, 17 (85,5%) had their vision preserved with no evidence of disease, while 3 (15%) had local failure and were underwent to enucleation. All patients are alive with no evidence of systemic disease. Conclusion: When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical team

  16. Corn silk aqueous extracts and intraocular pressure of systemic and non-systemic hypertensive subjects.

    Science.gov (United States)

    George, Gladys O; Idu, Faustina K

    2015-03-01

    Hypotensive properties have been attributed to the stigma/style of Zea mays L (corn silk). Although the effect of corn silk extract on blood pressure has been documented in animal studies, we are not aware of any study on its effect on human blood pressure and intraocular pressure. A randomised study was carried out on the effect of water only, masked doses of corn silk aqueous extract (60, 130, 192.5 and 260 mg/kg body weight) on intraocular pressure and blood pressure of 20 systemic and 20 non-systemic hypertensive subjects. Intraocular pressure and blood pressure were measured at baseline and every hour for eight hours after administering water or a masked dose of corn silk aqueous extract. Each dose was administered at two-week intervals to each subject in the two study groups. The results showed that the last three doses of corn silk aqueous extract gave a statistically significant reduction (p Corn silk aqueous extract has a lowering effect on intraocular pressure in systemic and non-systemic hypertensive subjects. This may have resulted from the fall in blood pressure that is due to potassium-induced natriuresis and diuresis caused by the high potassium content in the high doses of the corn silk extract. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  17. Socioeconomic and psychological impact of treatment for unilateral intraocular retinoblastoma.

    Science.gov (United States)

    Soliman, S E; Dimaras, H; Souka, A A; Ashry, M H; Gallie, B L

    2015-06-01

    To identify the socioeconomic and psychosocial impacts of clinical treatment decisions for advanced unilateral intraocular retinoblastoma. Retrospective observational case series. institutional study at Alexandria Main University Hospital. records of 66 unilateral retinoblastoma cases treated from May 2005 to May 2013 were retrospectively reviewed. Sixty cases were eligible (International Intraocular Retinoblastoma Classification [IIRC] group C, D or E). two treatment groups were compared: enucleation vs. salvage treatment. Salvage treatment eyes were further subdivided based on IIRC group. Six socioeconomic parameters (financial burden, financial impact, psychological, social, medical and tumor impacts) were scored. Parameter scores ranged from 0 to 3, for overall score range 0 (no adverse impact) to 18 (severe adverse impact). derived Socioeconomic scores were correlated with treatment and outcomes. The enucleation group (28 eyes) had a median overall Socioeconomic score of 4/18, significantly lower than the salvage treatment group (32 eyes), median score 11/18 (PSocioeconomic score varied with IIRC group. Attempted eye salvage failed in 25 children, due to uncontrolled tumor (44%) and socioeconomic impact of cumulative therapies (56%). Treatment duration and Socioeconomic score were higher for the 5 children in the salvage treatment group who developed metastatic disease compared to those without metastasis (Psocioeconomic and psychosocial impacts of attempted ocular salvage for unilateral intraocular retinoblastoma are severe, in comparison to primary enucleation. Primary enucleation is a good treatment for unilateral retinoblastoma. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  18. Right ventricular lipomatous mass and biventricular multifocal fat in a young woman: A case report

    International Nuclear Information System (INIS)

    Lee, Bo Rahm; Park, Jae Hyeong; Ahn, Kye Taek; Kim, Song Soo; Jeong, Jin Ok; Choi, Si Wan; Jin, Seon Ah; Lee, Jae Hwan

    2015-01-01

    Cardiac lipoma is a rare neoplasm of encapsulated mature adult adipose tissue. It is usually asymptomatic, but it may be related to hemodynamic obstruction depending on its location. We report a typical case of right ventricular lipomatous mass and multifocal fat infiltration of both ventricles, which were detected incidentally in a young woman.

  19. The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators.

    Science.gov (United States)

    2000-10-01

    To investigate the association between control of intraocular pressure after surgical intervention for glaucoma and visual field deterioration. In the Advanced Glaucoma Intervention Study, eyes were randomly assigned to one of two sequences of glaucoma surgery, one beginning with argon laser trabeculoplasty and the other trabeculectomy. In the present article we examine the relationship between intraocular pressure and progression of visual field damage over 6 or more years of follow-up. In the first analysis, designated Predictive Analysis, we categorize 738 eyes into three groups based on intraocular pressure determinations over the first three 6-month follow-up visits. In the second analysis, designated Associative Analysis, we categorize 586 eyes into four groups based on the percent of 6-month visits over the first 6 follow-up years in which eyes presented with intraocular pressure less than 18 mm Hg. The outcome measure in both analyses is change from baseline in follow-up visual field defect score (range, 0 to 20 units). In the Predictive Analysis, eyes with early average intraocular pressure greater than 17.5 mm Hg had an estimated worsening during subsequent follow-up that was 1 unit of visual field defect score greater than eyes with average intraocular pressure less than 14 mm Hg (P =.002). This amount of worsening was greater at 7 years (1.89 units; P <.001) than at 2 years (0.64 units; P =.071). In the Associative Analysis, eyes with 100% of visits with intraocular pressure less than 18 mm Hg over 6 years had mean changes from baseline in visual field defect score close to zero during follow-up, whereas eyes with less than 50% of visits with intraocular pressure less than 18 mm Hg had an estimated worsening over follow-up of 0.63 units of visual field defect score (P =.083). This amount of worsening was greater at 7 years (1.93 units; P <.001) than at 2 years (0.25 units; P =.572). In both analyses low intraocular pressure is associated with reduced

  20. Delivery of Intraocular Triamcinolone Acetonide in the Treatment of Macular Edema

    Directory of Open Access Journals (Sweden)

    Brent Siesky

    2012-03-01

    Full Text Available Macular edema (ME is one of the eventual outcomes of various intraocular and systemic pathologies. The pathogenesis for ME is not yet entirely understood; however, some of the common risk factors for its development have been identified. While this investigation will not discuss the numerous etiologies of ME in detail, it appraises the two most widely studied delivery modalities of intraocular corticosteroids in the treatment of ME—intravitreal injection (IVI and sub-Tenon’s infusion (STI. A thorough review of the medical literature was conducted to identify the efficacy and safety of IVI and STI, specifically for the administration of triamcinolone acetonide (TA, in the setting of ME in an attempt to elucidate a preferred steroid delivery modality for treatment of ME.

  1. Effect of intravenous metoclopramide on intraocular pressure: A prospective, randomized, double-blind, placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Sudheera K

    2008-01-01

    Full Text Available Background: Prevention of rise in intraocular pressure (IOP is essential in patients undergoing surgery for perforated eye injuries. Metoclopramide, a prokinetic agent, is commonly used to hasten gastric emptying in emergency surgeries. Aim: To study the change in IOP after intravenous metoclopramide and to study the influence of metoclopramide on change in IOP after succinylcholine and tracheal intubation. Settings and Design: A randomized, double-blind, placebo-controlled study of 60 patients undergoing non-ophthalmic elective surgery. Materials and Methods: Sixty American Society of Anesthesiologists (ASA I adult patients were randomly assigned to receive normal saline (Group C or metoclopramide 10 mg (Group M 30 min before the induction of anesthesia. Thiopentone was used for induction and succinylcholine for tracheal intubation. Intraocular pressure was measured in both the eyes pre and post drug treatment and succinylcholine and tracheal intubation using Perkins applanation tonometer. Statistical Analysis: Student′s t-test and repeated measures ANOVA were used. A P value < 0.05 was considered as significant. Results: Intraocular pressure was consistently lower in Group M than in Group C after the test drug, though the difference was not statistically significant. Intraocular pressure decreased significantly after administration of thiopentone and increased significantly in Groups C and M after tracheal intubation ( P < 0.01. Intraocular pressure was comparable between the groups at all the times. Conclusions: Metoclopramide does not cause a clinically significant change in IOP nor does it influence the changes in IOP during anesthesia and tracheal intubation. Metoclopramide shows a trend towards decrease in IOP, though clinically insignificant. Therefore metoclopramide can be used to promote gastric emptying in patients with perforated eye injury.

  2. Neodymium:YAG laser cutting of intraocular lens haptics.

    Science.gov (United States)

    Gorn, R A; Steinert, R F

    1985-11-01

    Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.

  3. Tolerance analysis on diffraction efficiency and polychromatic integral diffraction efficiency for harmonic diffractive optics

    Science.gov (United States)

    Shan, Mao

    2016-10-01

    In this dissertation, the mathematical model of effect of manufacturing errors including microstructure relative height error and relative width error on diffraction efficiency for the harmonic diffractive optical elements (HDEs) is set up. According to the expression of the phase delay and diffraction efficiency of the HDEs, the expression of diffraction efficiency of refraction and diffractive optical element with the microstructure height and periodic width errors in fabrication process is presented in this paper. Furthermore, the effect of manufacturing errors on diffraction efficiency for the harmonic diffractive optical elements is studied, and diffraction efficiency change is analyzed as the relative microstructure height-error in the same and in the opposite sign as well as relative width-error in the same and in the opposite sign. Example including infrared wavelength with materials GE has been discussed in this paper. Two kinds of manufacturing errors applied in 3.7 4.3um middle infrared and 8.7-11.5um far infrared optical system which results in diffraction efficiency and PIDE of HDEs are studied. The analysis results can be used for manufacturing error control in micro-structure height and periodic width. Results can be used for HDEs processing.

  4. Multifocal Spinal Cord Nephroblastoma in a Dog.

    Science.gov (United States)

    Henker, L C; Bianchi, R M; Vargas, T P; de Oliveira, E C; Driemeier, D; Pavarini, S P

    2018-01-01

    A 1-year-old male American pit bull terrier was presented with a history of proprioceptive deficits and mild lameness of the right hindlimb, which progressed after 5 months to paraparesis, culminating in tetraparesis after 2 weeks. Necropsy findings were limited to the spinal cord and consisted of multiple, intradural, extramedullary, slightly red masses which produced segmental areas of medullary swelling located in the cervical intumescence, thoracolumbar column, sacral segment and cauda equina. Histological evaluation revealed a tumour, composed of epithelial, stromal and blastemal cells, with structures resembling tubules, acini and embryonic glomeruli. Immunohistochemical labelling for vimentin, cytokeratin and S100 was positive for the stromal, epithelial and blastemal cells, respectively. A final diagnosis of multifocal spinal cord nephroblastoma was established. This is the first report of such a tumour showing concomitant involvement of the cervicothoracic, thoracolumbar, sacral and cauda equina areas of the spinal cord. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Primary intraocular chondrosarcoma in a dog

    Directory of Open Access Journals (Sweden)

    E. Perlmann

    2013-12-01

    Full Text Available A five-year-old male Cocker Spaniel was presented for evaluation of the right eye due to discomfort, abundant purulent discharge and progressive enlargement of the eyeball. The owner revealed that the right eye has appeared to be inflamed and smaller then the left eye for years. Ophthalmic examination revealed corneal perforation, buphthalmia and conjuctival hyperemia. Enucleating was performed due to signs of endophthalmitis and ocular discomfort. Histopathology revealed a multilobulated proliferation of chondrocytes producing hyaline cartilage with occasional pleomorphism and binucleate cells. A diagnosis of primary intraocular chondrosarcoma was done.

  6. Variation of stemness markers expression in tumor nodules from synchronous multi-focal hepatocellular carcinoma - an immunohistochemical study.

    Science.gov (United States)

    Lo, Regina Cheuk-Lam; Leung, Carmen Oi-Ning; Chok, Kenneth Siu-Ho; Ng, Irene Oi-Lin

    2017-08-01

    Advancing knowledge in molecular pathogenesis of hepatocellular carcinoma (HCC) opens up new horizons in the diagnostic, prognostic and therapeutic perspectives. Assessing the expression of molecular targets prior to definitive treatment is gaining importance in clinical practice. In this study, we investigated the variation in expression pattern of stemness markers in synchronous multi-focal HCC. In the first cohort, 21 liver explants with multi-focal HCC were examined for expression of stemness markers EpCAM, Sox9 and CK19 by immunohistochemistry (IHC). Expression data of 50 tumor nodules were analyzed to determine the concordance of expression among nodules in the same livers. In the second cohort, 14 tumor nodules from 6 multi-focal HCC cases proven as intra-hepatic metastasis were examined for Soc9 immunoexpression. In the first cohort, thirty nodules from 16 cases expressed one or more markers, with Sox9 being most frequently expressed. Complete concordance of expression pattern for all 3 markers was observed in 6 cases. Discrepancy of staining degree was noted in 4 cases for EpCAM, 14 cases for Sox9, and 6 cases for CK19. A two-tier or three-tier difference in staining scores was noted in 5 cases for Sox9 and one case for CK19. With Sox9, identical tumor morphology in terms of Edmondson grading and growth pattern did not infer the same degree of immunoexpression; and the largest tumor nodule was not representative of highest IHC score. In the second cohort of intra-hepatic metastasis, complete concordance of Sox9 expression level was observed in 5 out of 6 cases; while the remaining case showed a 1-tier difference of positive staining. Our findings suggested that clonality of tumor nodules is apparently an important factor to infer immunoexpression pattern. When there is limited information to discern multiple primaries versus intra-hepatic metastasis in multi-focal HCC, discordant degree of stemness markers expression among tumor nodules was commonly

  7. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  8. Acute posterior multifocal placoid pigment epitheliopathy associated with cerebral vasculitis.

    Science.gov (United States)

    Weinstein, J M; Bresnick, G H; Bell, C L; Roschmann, R A; Brooks, B R; Strother, C M

    1988-09-01

    Acute multifocal posterior placoid pigment epitheliopathy (APMPPE) is an unusual self-limited retinal disorder that has been associated with various systemic complications. To our knowledge, three prior cases associated with cerebral vasculitis have been described. This article describes a patient with APMPPE and angiographically documented cerebral vasculitis who was notable because of (a) the presence of two different cerebral ischemic events, occurring 1 month apart, and (b) the long latency (3 months) between the onset of ocular symptoms and the second cerebral ischemic event. Recognition of the association between APMPPE and cerebral vasculitis may permit early treatment of CNS involvement and prevention of morbidity.

  9. Aggressive and multifocal pulmonary inflammatory myofiberblastic tumor in young woman

    International Nuclear Information System (INIS)

    Choi, Yang Sean; Chung, Myung Hee; Kim, Hyun Jung; Park, Ki Hoon; Kim, Jeanna; Kwon, Soon Suck; Yoo, Won Jong

    2016-01-01

    We report a case of pulmonary inflammatory myofibroblastic tumor (IMT) showing aggressive and unusually rapid progression. A 27-year-old woman was admitted to the emergency room due to dry cough, fever and blood-tinged sputum that lasted one week. Initial chest radiograph and computed tomography scan revealed multifocal pulmonary nodules, which subsequently progressed into large necrotic masses within two months. She underwent a fine needle biopsy of the largest mass in the right middle lung zone which revealed inflammatory myofibroblastic cells consistent with IMT. The masses showed complete regression after six months of corticosteroid therapy. This unusual clinical manifestation could help explain the reactive inflammatory nature associated with IMTs

  10. Aggressive and multifocal pulmonary inflammatory myofiberblastic tumor in young woman

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yang Sean; Chung, Myung Hee; Kim, Hyun Jung; Park, Ki Hoon; Kim, Jeanna; Kwon, Soon Suck; Yoo, Won Jong [Bucheon St. Mary' s Hospital, The Catholic University of Korea, Bucheon (Korea, Republic of)

    2016-08-15

    We report a case of pulmonary inflammatory myofibroblastic tumor (IMT) showing aggressive and unusually rapid progression. A 27-year-old woman was admitted to the emergency room due to dry cough, fever and blood-tinged sputum that lasted one week. Initial chest radiograph and computed tomography scan revealed multifocal pulmonary nodules, which subsequently progressed into large necrotic masses within two months. She underwent a fine needle biopsy of the largest mass in the right middle lung zone which revealed inflammatory myofibroblastic cells consistent with IMT. The masses showed complete regression after six months of corticosteroid therapy. This unusual clinical manifestation could help explain the reactive inflammatory nature associated with IMTs.

  11. Intraocular 6-hydroxydopamine prevents the persistent estrus induced by continuous light.

    Science.gov (United States)

    Shimizu, K; Hokano, M

    1985-01-15

    Following the intraocular injection of 6-hydroxydopamine, which can destroy the retinal dopaminergic neurons, female rats showed a normal estrous cycle in LD 12:12 but not a persistent estrus in continuous light.

  12. Multifocal electroretinogram for functional evaluation of retinal injury following ischemia-reperfusion in pigs

    DEFF Research Database (Denmark)

    Morén, Håkan; Gesslein, Bodil; Andreasson, Sten

    2010-01-01

    Multifocal electroretinogram (mfERG) has the power to discriminate between localized functional losses and overall retinal changes when evaluating retinal injury. So far, full-field ERG has been the gold standard for examining retinal ischemia and the effects of different neuroprotectants...... in experimental conditions. The aim of the present study was to establish mfERG, with simultaneous fundus monitoring, for analyzing the localized functional response in the retina after ischemia-reperfusion in the porcine eye....

  13. Recurrent multifocal cutaneous Kaposiform hemangioendothelioma: A rare vascular tumor of infancy and childhood.

    Science.gov (United States)

    Atla, Bhagyalakshmi; Sudhakar, P V; Rao, Nagarjun; Prasad, Uma

    2016-01-01

    Kaposiform hemangioendothelioma (KHE) is a locally aggressive vascular tumor of childhood although cases occurring in adulthood are also described. The features overlap with juvenile capillary hemangioma and Kaposi sarcoma. We report a rare case of recurrent, multifocal (nose and chin) cutaneous KHE initially occurring in a 3-year-old female child, uncomplicated by Kasabach-Merritt syndrome. Recurrences occurred over the next 6 years and resulted in complete distortion of the nose, requiring plastic repair.

  14. Effect of hemodialysis on intraocular lens power calculation.

    Science.gov (United States)

    Çalışkan, Sinan; Çelikay, Osman; Biçer, Tolga; Aylı, Mehmet Deniz; Gürdal, Canan

    2016-01-01

    To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Mean difference in AL before and after HD was -0.041 ± 0.022 mm with ICCs > 0.90 (p  0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.

  15. HMB-45 negative multifocal malignant perivascular epithelioid cell tumor of the soft tissue responding to sirolimus: First case report from India.

    Science.gov (United States)

    Kapoor, Akhil; Beniwal, Surender; Singhal, Mukesh Kumar; Kumar, Narender; Kumar, Vanita; Kumar, Harvindra Singh

    2015-01-01

    Perivascular epithelioid cell tumor (PEComa) is a group of sarcomas that exhibit a myomelanocytic phenotype and possess a unique cell type in the perivascular epithelioid cell. Traditionally HMB-45 immunoreactivity is the first criteria required to consider a tumor to be PEComa. We report a case of multifocal PEComa with negative HMB-45 marker. The patient presented with three big ulceroproliferative lesions; two over right thigh and one over the scalp in the right frontal region. The patient was prescribed with oral sirolimus to which good response was seen. To the best of our knowledge, this is the first case of HMB-45 negative multifocal malignant PEComa from India.

  16. Associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu Association between two different types of strangling and intraocular pressure variation in jiu-jitsu athletes

    Directory of Open Access Journals (Sweden)

    Marinho Jorge Scarpi

    2009-06-01

    Full Text Available OBJETIVO: Verificar a associação entre dois diferentes tipos de estrangulamento com a variação da pressão intraocular em atletas de jiu-jitsu. MÉTODO: Estudo observacional em grupo de 9 atletas de jiu-jitsu, com mínimo 6 meses de treinamento, sexo masculino, idades entre 20 e 30 anos, sem presença de lesões físicas e do bulbo ocular. Buscou-se associação entre a variação da pressão intraocular e os estrangulamentos Frontal da Guarda (E1 e Frontal da Montada (E2. A pressão intraocular foi determinada com o tonômetro de Perkins, inicialmente sem que o atleta tivesse realizado atividade física nas 24 horas antecedentes e após cada golpe. Realizou-se medidas da pressão intraocular por 12 minutos, uma a cada 3 minutos de recuperação (R1; R2; R3; R4, com o indivíduo deitado. Como procedimento estatístico foi empregado o teste ANOVA e o pós-teste de Bonferroni. RESULTADOS: Ocorreu redução significativa da pressão intraocular em ambos os olhos durante a situação E2 comparada a E1 em todos os momentos da aferição de recuperação: R1 (OD: 8,22 ± 1,39 vs.11,33 ± 2,00 / OE: 8,55 ± 1,23 vs. 11,88 ± 1,90, R2 (OD: 8,44 ± 1,87 vs.10,22 ± 2,53 / OE: 9,00 ± 1,80 vs. 10,44 ± 2,35, R3 (OD: 8,44 ± 1,74 vs.9,78 ± 2,54 / OE: 8,55 + 1,42 vs. 10,33 ± 1,93 todos com pPURPOSE: To verify the association between two different types of strangling with intraocular pressure variation in jiu-jitsu athletes. METHODS: An observational study was performed on 9 athletes of jiu-jitsu, with at least 6 month of training, male, aged 20 to 30 years, without any physical and eyeball lesions. Associations between intraocular pressure and Cross Choke from the guard strangling (E1, and E2 - Cross Choke from mount strangling were gotten. Intraocular pressure was determined by using Perkins tonometer, at first in the absence of physical exercise over the last 24 hours and after each strangling. Then it was carried out the intraocular pressure

  17. Incidental caseating granuloma of thyroid gland presenting with concomitant Graves′ disease and multifocal papillary microcarcinoma

    Directory of Open Access Journals (Sweden)

    Muneera A Al Shareef

    2013-01-01

    Full Text Available A 36-year-old Saudi woman presented with symptoms and signs of hyperthyroidism and was diagnosed to have Graves′ disease. She was initially treated with antithyroid medications with no response. Subsequently, she underwent a total thyroidectomy. The histopathology of the specimen revealed caseating granulomatous thyroid suggestive of tuberculosis and multifocal papillary thyroid microcarcinoma

  18. Intermediate-term and long-term outcome of piggyback drainage: connecting glaucoma drainage device to a device in-situ for improved intraocular pressure control.

    Science.gov (United States)

    Dervan, Edward; Lee, Edward; Giubilato, Antonio; Khanam, Tina; Maghsoudlou, Panayiotis; Morgan, William H

    2017-11-01

    This study provides results of a treatment option for patients with failed primary glaucoma drainage device. The study aimed to describe and evaluate the long-term intraocular pressure control and complications of a new technique joining a second glaucoma drainage device directly to an existing glaucoma drainage device termed 'piggyback drainage'. This is a retrospective, interventional cohort study. Eighteen eyes of 17 patients who underwent piggyback drainage between 2004 and 2013 inclusive have been studied. All patients had prior glaucoma drainage device with uncontrolled intraocular pressure. The piggyback technique involved suturing a Baerveldt (250 or 350 mm) or Molteno3 glaucoma drainage device to an unused scleral quadrant and connecting the silicone tube to the primary plate bleb. Failure of intraocular pressure control defined as an intraocular pressure greater than 21 mmHg on maximal therapy on two separate occasions or further intervention to control intraocular pressure. The intraocular pressure was controlled in seven eyes (39%) at last follow-up with a mean follow-up time of 74.2 months. The mean preoperative intraocular pressure was 27.1 mmHg (95% confidence interval 23.8-30.3) compared with 18.4 mmHg (95% confidence interval 13.9-22.8) at last follow-up. The mean time to failure was 57.1 months (95% confidence interval 32.2-82), and the mean time to further surgery was 72.3 months (95% confidence interval 49.9-94.7). Lower preoperative intraocular pressure was associated with longer duration of intraocular pressure control (P = 0.048). If the intraocular pressure was controlled over 2 years, it continued to be controlled over the long term. Two eyes (11%) experienced corneal decompensation. Piggyback drainage represents a viable surgical alternative for the treatment of patients with severe glaucoma with failing primary glaucoma drainage device, particularly in those at high risk of corneal decompensation. © 2017 Royal Australian and New Zealand

  19. Human Intraocular Filariasis Caused by Dirofilaria sp. Nematode, Brazil

    Science.gov (United States)

    Diniz, Daniel G.; Dantas-Torres, Filipe; Casiraghi, Maurizio; de Almeida, Izabela N.F.; de Almeida, Luciana N.F.; Nascimento dos Santos, Jeannie; Furtado, Adriano Penha; Sobrinho, Edmundo F. de Almeida; Bain, Odile

    2011-01-01

    A case of human intraocular dirofilariasis is reported from northern Brazil. The nematode was morphologically and phylogenetically related to Dirofilaria immitis but distinct from reference sequences, including those of D. immitis infesting dogs in the same area. A zoonotic Dirofilaria species infesting wild mammals in Brazil and its implications are discussed. PMID:21529396

  20. Branch retinal artery occlusion post-penetrating globe injury with intraocular foreign body.

    Science.gov (United States)

    Nagpal, Manish; Chaudhary, Pranita; Jain, Ashish

    2018-01-01

    Intraocular foreign body (IOFB) in cases of penetrating eye injury accounts for an important indication of vitreoretinal intervention following ocular trauma. Vascular occlusion as a complication of IOFB is rare. Here we present a case of a 34-year-old male with post-traumatic cataract and an intraocular metallic foreign body (IOFB) lodged in the superficial layers of the retina inferotemporal to the disc, causing an inferotemporal branch retinal artery occlusion. The case was managed by lensectomy with pars plana vitrectomy and IOFB removal followed by a second procedure of secondary IOL implantation. Final best-corrected visual acuity improved to 6/24. This case highlights an unusual sequelae following penetrating ocular trauma.

  1. Branch retinal artery occlusion post-penetrating globe injury with intraocular foreign body

    Directory of Open Access Journals (Sweden)

    Manish Nagpal

    2018-01-01

    Full Text Available Intraocular foreign body (IOFB in cases of penetrating eye injury accounts for an important indication of vitreoretinal intervention following ocular trauma. Vascular occlusion as a complication of IOFB is rare. Here we present a case of a 34-year-old male with post-traumatic cataract and an intraocular metallic foreign body (IOFB lodged in the superficial layers of the retina inferotemporal to the disc, causing an inferotemporal branch retinal artery occlusion. The case was managed by lensectomy with pars plana vitrectomy and IOFB removal followed by a second procedure of secondary IOL implantation. Final best-corrected visual acuity improved to 6/24. This case highlights an unusual sequelae following penetrating ocular trauma.

  2. Multifocal epithelial hyperplasia: a forgotten condition in the elderly.

    Science.gov (United States)

    Shamloo, Nafiseh; Mortazavi, Hamed; Taghavi, Nasim; Baharvand, Maryam

    2016-01-01

    Multifocal epithelial hyperplasia (MEH), also known as focal epithelial hyperplasia and Heck disease, is a relatively rare condition caused by the human papillomavirus. This case report describes a 92-year-old man who presented with multiple, asymptomatic, circumscribed, soft, flattened papules in different sizes on the retrocommissure of his lower lip. The lesions were of 2 months' duration and had the same coloration as the adjacent normal mucosa. Histopathologic examination showed orthokeratinized stratified squamous epithelium with acanthosis, some areas of club-shaped rete ridges, and a few superficial epithelial cells with koilocytic changes and a mitosoid-like appearance. A diagnosis of MEH was established. Although MEH tends to occur in the first 2 decades of life, it can be encountered in elderly patients as well.

  3. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Bikramjit Das

    2016-02-01

    Full Text Available BACKGROUND: We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. METHODS: Ninety adult patients were randomly assigned to study group or control group. Study group (n = 45 - Airtraq laryngoscope was used for laryngoscopy. Control group (n = 45 - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. RESULTS: Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. CONCLUSION: We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation.

  4. Can ratio of the biggest tumor diameter to total tumor diameter be a new parameter in the differential diagnosis of agressive and favorable multifocal papillary thyroid microcarcinoma?

    Science.gov (United States)

    Tam, Abbas Ali; Özdemir, Didem; Çuhacı, Neslihan; Başer, Hüsniye; Dirikoç, Ahmet; Aydın, Cevdet; Yazgan, Aylin Kılıç; Ersoy, Reyhan; Çakır, Bekir

    2017-02-01

    In this study, we aimed to evaluate the usefulness of a new parameter -ratio of the biggest tumor diameter to total tumor diameter- for the differentiation of agressive and favorable papillary thyroid microcarcinomas (PTMC). The diameter of the biggest tumor focus was taken as the primary tumor diameter. Total tumor diameter was calculated as the sum of the maximal diameter of each lesion. Ratio of primary tumor diameter to total tumor diameter was defined as tumor diameter ratio (TDR). Positive and negative predictive value, sensitivity and specificity of TDR to predict capsular invasion, extrathyroidal extension (ETE) and lymph node metastasis (LNM) were determined. Mean TDR was significantly lower in multifocal PTMC patients with capsular invasion, ETE, lymphovascular invasion and LNM compared to patients without these features. The sensitivities of TDR for the detection of LNM, ETE and capsular invasion were 100%, 100% and 94.2%, respectively. Specificity of TDR was 86.2% for LNM, 88% for ETE and 94.7% for capsular invasion. Best cut off values of TDR that can predict capsular invasion, ETE and LNM in multifocal PTMC were 0.62, 0.57 and 0.56, respectively. Multifocal papillary thyroid carcinoma patients with capsular invasion, ETE and LNM had significantly lower mean TDR when compared to ones without these features. Decreased TDR was associated with capsular invasion, ETE and LNM in patients with multifocal PTMC and PTC. This new parameter might be particularly helpful for the detection of aggressive behavior in multifocal PTMCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Role of light and the circadian clock in the rhythmic oscillation of intraocular pressure: Studies in VPAC2 receptor and PACAP deficient mice.

    Science.gov (United States)

    Fahrenkrug, Jan; Georg, Birgitte; Hannibal, Jens; Jørgensen, Henrik Løvendahl

    2018-04-01

    The intraocular pressure of mice displays a daily rhythmicity being highest during the dark period. The present study was performed to elucidate the role of the circadian clock and light in the diurnal and the circadian variations in intraocular pressure in mice, by using animals with disrupted clock function (VPAC2 receptor knockout mice) or impaired light information to the clock (PACAP knockout mice). In wildtype mice, intraocular pressure measured under light/dark conditions showed a statistically significant 24 h sinusoidal rhythm with nadir during the light phase and peak during the dark phase. After transfer of the wildtype mice into constant darkness, the intraocular pressure increased, but the rhythmic changes in intraocular pressure continued with a pattern identical to that obtained during the light/dark cycle. The intraocular pressure in VPAC2 receptor deficient mice during light/dark conditions also showed a sinusoidal pattern with significant changes as a function of a 24 h cycle. However, transfer of the VPAC2 receptor knockout mice into constant darkness completely abolished the rhythmic changes in intraocular pressure. The intraocular pressure in PACAP deficient mice oscillated significantly during both 24 h light and darkness and during constant darkness. During LD conditions, the amplitude of PACAP deficient was significantly lower compared to wildtype mice, resulting in higher daytime and lower nighttime values. In conclusion, by studying the VPAC2 receptor knockout mouse which lacks circadian control and the PACAP knockout mouse which displays impaired light signaling, we provided evidence that the daily intraocular pressure rhythms are primarily generated by the circadian master clock and to a lesser extent by environmental light and darkness. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Computational modeling of intraocular gas dynamics

    International Nuclear Information System (INIS)

    Noohi, P; Abdekhodaie, M J; Cheng, Y L

    2015-01-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF_6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF_6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF_6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF_6 is 1.4 times more than that of using diluted SF_6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency. (paper)

  7. Recurrent multifocal cutaneous Kaposiform hemangioendothelioma: A rare vascular tumor of infancy and childhood

    Directory of Open Access Journals (Sweden)

    Bhagyalakshmi Atla

    2016-01-01

    Full Text Available Kaposiform hemangioendothelioma (KHE is a locally aggressive vascular tumor of childhood although cases occurring in adulthood are also described. The features overlap with juvenile capillary hemangioma and Kaposi sarcoma. We report a rare case of recurrent, multifocal (nose and chin cutaneous KHE initially occurring in a 3-year-old female child, uncomplicated by Kasabach–Merritt syndrome. Recurrences occurred over the next 6 years and resulted in complete distortion of the nose, requiring plastic repair.

  8. Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India.

    Science.gov (United States)

    Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice

    2015-01-01

    To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients' outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p=0.02). Experienced practitioners were observed to be least motivated (p=0.01) and believed that their patients found these lenses expensive (p=0.02). To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  9. Multifocal Abrikossoff's granular cell tumor of the oesophagus: Case report

    Directory of Open Access Journals (Sweden)

    Ranđelović Tomislav D.

    2008-01-01

    Full Text Available INTRODUCTION Granular cell tumors, relatively uncommon soft tissue tumors, have been a matter of debate among pathologists regarding histogenesis for a long time. Less common locations are in the aerodigestive tract including the oesophagus. CASE OUTLINE We have recently treated a rare case, a 37-year old male, who was admitted due to dysphagia and a painful swallow with occasional pharyngo-nasal regurgitation followed with a mild loss of weight. Standard clinical examination including X-ray chest, ECG and laboratory tests did not show pathological findings. Barium contrast oesophagography demonstrated multiple ovoid defects in the wall of the oesophagus. CT scan of the chest confirmed luminal narrowing owing to the tumor of the upper oesophagus. Upper endoscopy showed unusual multifocal nodular lesions alongside the oesophageal axis covered by smooth mucosa. A primary biopsy specimen taken from the largest nodules confirmed an unusual pathological finding of the granular cell tumor. Subtotal, transpleural oesophagectomy was performed and reconstruction was derived by long colon segment interposition through the posterior mediastinum. The postoperative course was uneventful. The operative specimen consisted of four ovoid tumors alongside the oesophagus (the greatest diameter 0.5-1.8, average 1.25. All verified tumors histologicaly consisted of a spindle-shaped or polygonal cells containing small and large eosinophilic granules and central nuclei. Most tumor cells showed strongly positive immunohistochemical staining for S-100 protein. These tumor cells were partially positive for p-53 and Ki-67. No lymph node metastases were detected histologically. CONCLUSION Multifocal granular cell tumor of the oesophagus is an unusual finding with low incidence, and rarely caused symptoms. Pathological features and multiplicity of such tumors emphasized malignant predisposition requiring surgical resection of the oesophagus.

  10. Multi-focal lobular carcinoma in situ arising in benign phylodes tumor: A case report

    International Nuclear Information System (INIS)

    Lee, Taeg Ki; Choi, Chang Hwan; Kim, Youn Jeong; Kim, Mi Young; Lee, Kyung Hee; Cho, Soon Gu

    2015-01-01

    Coexistent breast malignancy arising in phyllodes tumor is extremely rare, and most of them are incidental reports after surgical excision. Coexistent malignancy in phyllodes tumor can vary from in-situ to invasive carcinoma. Lobular neoplasia is separated into atypical lobular hyperplasia and lobular carcinoma in situ (LCIS). LCIS is known to have a higher risk of developing invasive cancer. We reported imaging findings of multifocal LCIS arising in benign phyllodes tumor

  11. Multi-focal lobular carcinoma in situ arising in benign phylodes tumor: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taeg Ki; Choi, Chang Hwan; Kim, Youn Jeong; Kim, Mi Young; Lee, Kyung Hee; Cho, Soon Gu [Inha University Hospital, Incheon (Korea, Republic of)

    2015-08-15

    Coexistent breast malignancy arising in phyllodes tumor is extremely rare, and most of them are incidental reports after surgical excision. Coexistent malignancy in phyllodes tumor can vary from in-situ to invasive carcinoma. Lobular neoplasia is separated into atypical lobular hyperplasia and lobular carcinoma in situ (LCIS). LCIS is known to have a higher risk of developing invasive cancer. We reported imaging findings of multifocal LCIS arising in benign phyllodes tumor.

  12. Raised intraocular pressure and recurrence of retinal detachment as complications of external retinal detachment surgery

    International Nuclear Information System (INIS)

    Jawwad, M.; Khan, B.; Shah, M.A.; Qayyum, I.; Aftab, M.; Qayyum, I.

    2015-01-01

    Patients with Rhegmatogenous retinal detachment may develop raised intraocular pressure and recurrence of retinal detachment when they undergo external retinal detachment surgery. The present study was conducted to determine the postoperative rise in intraocular pressure (IOP) and recurrence of retinal detachment. Methods: The present descriptive study was conducted at Eye department of Lady Reading Hospital, Peshawar on 25 patients of both genders from August 2012 to July 2014. Results: Of the 25 patients, 18 (72%) developed raised IOP in the immediate postoperative period; this figure decreased to 12 (48%) at one week. Following medical or surgical intervention in these 12 cases, there was only 1 (4%) case with mildly raised IOP at two weeks postoperative. Five (20%) cases developed recurrent retinal detachment which later resolved with treatment. There were no significant differences by age or gender. Conclusion: External Retinal Detachment Surgery raised intraocular pressure postoperatively and caused recurrence of retinal detachment. These complications were treated medically and surgically with resolution within two weeks. (author)

  13. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  14. Multifocal bone and bone marrow lesions in children - MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Raissaki, Maria; Demetriou, Stelios; Spanakis, Konstantinos; Skiadas, Christos; Karantanas, Apostolos H. [University of Crete, Faculty of Medicine, Department of Radiology, University Hospital of Heraklion, Heraklion, Crete (Greece); Katzilakis, Nikolaos; Stiakaki, Eftichia [University of Crete, Faculty of Medicine, Department of Pediatric Hematology-Oncology, University Hospital of Heraklion, Heraklion, Crete (Greece); Velivassakis, Emmanouil G. [University Hospital of Heraklion, Orthopedic Clinic, Heraklion, Crete (Greece)

    2017-03-15

    Polyostotic bone and bone marrow lesions in children may be due to various disorders. Radiographically, lytic lesions may become apparent after loss of more than 50% of the bone mineral content. Scintigraphy requires osteoblastic activity and is not specific. MRI may significantly contribute to the correct diagnosis and management. Accurate interpretation of MRI examinations requires understanding of the normal conversion pattern of bone marrow in childhood and of the appearances of red marrow rests and hyperplasia. Differential diagnosis is wide: Malignancies include metastases, multifocal primary sarcomas and hematological diseases. Benign entities include benign tumors and tumor-like lesions, histiocytosis, infectious and inflammatory diseases, multiple stress fractures/reactions and bone infarcts/ischemia. (orig.)

  15. Progressive Multifocal Leukoencephalopathy [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Laura Adang

    2015-12-01

    Full Text Available Progressive multifocal leukoencephalopathy (PML is a devastating demyelinating disease with significant morbidity and mortality and no effective, targeted therapies. It is most often observed in association with abnormalities of cell-mediated immunity, in particular human immunodeficiency virus (HIV infection, but also occurs in association with lymphoproliferative diseases, certain immunosuppressive and immunomodulatory regimens, and other conditions. The etiologic agent of PML is a small, ubiquitous polyomavirus, the JC virus (JCV, also known as JCPyV, for which at least 50% of the adult general population is seropositive. PML results when JCV replicates within cerebral oligodendrocytes and astrocytes, leading to oligodendrocyte death and demyelination. Unfortunately, no treatments have been convincingly demonstrated to be effective, though some have been employed in desperation; treatment otherwise includes attempts to restore any immune system defect, such as the withdrawal of the causative agent if possible, and general supportive care.

  16. Comparação de resposta da pressão intraocular frente a duas diferentes intensidades e volumes do treinamento resistido

    Directory of Open Access Journals (Sweden)

    Marcelo Conte

    2014-01-01

    Full Text Available Objetivo: Verificar a influência de duas diferentes intensidades e volumes de treinamento resistido na pressão intraocular. Método: Dezenove boxeadores (13 homens e 6 mulheres; idade média de 22 ± 3 anos foram randomicamente submetidos a duas diferentes sessões de exercícios resistidos: resistência muscular com 3 séries de 15 repetições máximas e hipertrofia muscular com 4 séries de 8RM. A pressão intraocular foi obtida com Tonometro de Perkins antes, durante e após as sessões de exercício resistido. Os dados foram expressos em média e desvio padrão. Foi realizada análise de variância (ANOVA com medidas repetidas e pós teste de Tukey. Resultados: Foi observada redução da pressão intraocular durante as sessões de treinamento resistido. Contudo, a sessão de exercício para resistência muscular promoveu uma redução significativa da pressão intraocular comparada a de hipertrofia muscular. Ao final da sessão de resistência muscular a pressão intraocular retornou aos valores prévios ao exercício, por outro lado na sessão de hipertrofia muscular a pressão intraocular após o término dos exercícios apresentou-se acima dos valores iniciais. Conclusão: O treinamento resistido pode influenciar os valores da pressão intraocular, especificamente 3 séries de 15 repetições com 60% de 1RM promoveu respostas hipotensivas mais expressivas na pressão intraocular do que 3 séries de 8 repetições com 80% de 1RM. Esses achados podem contribuir para prescrição de exercício resistido para pessoas com fatores de risco para o glaucoma.

  17. The brain triuno and the ethical intelligence: fundamental counterfoil of the multifocal intelligence

    Directory of Open Access Journals (Sweden)

    C. Seijo

    2013-10-01

    Full Text Available This study has for aim offer an analysis as for the brain triuno and the ethical intelligence: fundamental Counterfoil of the multifocal intelligence, taking in tells one of the theories that it sustains her like they are the different types of multiple intelligences established by Beauport and Cury (2004. The theoretical sustenance, it is based on the contents of Martin (2005, Belohlavek (2007, Galicians (2002, Beauport and Cury (2004, between others, being realized under a symbolic interpretive approach, across a qualitative methodology, type descriptive and not experimental design, by means of a documentary analysis. In this regard, it is found that the ethical intelligence is a mental mechanism that constructs the structural preconceptos and the rules of game with which an individual approaches the reality, that is to say, it is the capacity of the general formation, predicting the behavior for the achievement of aims organizacionales. As for the final considerations they focused in obtaining the most wide knowledge inside the organizations, allowing to reflect before the weaknesses that they present thinking about the brain triuno applying the multifocal intelligence, fundamental counterfoil of the ethical intelligence and of what way the rationing visualizes the strengths, nevertheless of the weaknesses that they present. 

  18. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  19. Personalización de las constantes en las fórmulas de cálculo de la lente intraocular Personalization of constants in the intraocular lens calculation formulas

    Directory of Open Access Journals (Sweden)

    Anneé Miranda Carracedo

    2012-12-01

    Full Text Available Objetivo: personalizar las constantes A, factor cirujano y profundidad de la cámara anterior para las fórmulas de cálculo de la lente intraocular en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" de mayo de 2007 a enero de 2011. Métodos: se realizó un estudio descriptivo retrospectivo donde se estudiaron las constantes A, factor cirujano y profundidad de la cámara anterior. También se evaluó la longitud axial preoperatoria por IOL Master, la mejor agudeza visual sin corrección, el componente esférico esperado, el componente esférico obtenido y los resultados refractivos. Resultados: las constantes optimizadas por interferometría de coherencia parcial son diferentes a las propuestas por los fabricantes de las lentes intraoculares. Estas constantes personalizadas para cada cirujano no mostraron diferencias significativas. Las constantes optimizadas según las longitudes axiales, tienen diferencias significativas en los 3 grupos de estudio. La diferencia entre la lente intraocular implantada y la propuesta con las nuevas constantes resultó menor de 1 D de error en 83,1 % de los pacientes. El 75,4 % quedó bien corregido en relación con la diferencia entre la refracción esperada y la obtenida. Conclusiones: las constantes optimizadas por interferometría de coherencia parcial resultan más elevadas que las propuestas por el fabricante. La optimización de estas en el cálculo de la lente permite, de acuerdo a las características individuales de cada ojo (longitud axial, usar la fórmula adecuada e incrementa la predictibilidad de los resultados refractivos posoperatorios.Objective: to personalize the A, surgeon factor and anterior chamber depth constants for intraocular lens calculation formulas in the cataract surgery at the “Ramón Pando Ferrer” Cuban Ophthalmological Institute from May 2007 to January 2011. Method: a retrospective and descriptive study was made to study the A constant

  20. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Tendal, Britta

    2016-01-01

    TOPIC: We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were...

  1. Clinical observation of four-fixable intraocular lens suspensory

    Directory of Open Access Journals (Sweden)

    Yu-Ming Teng

    2015-06-01

    Full Text Available AIM: To discuss the four-fixable intraocular lens(IOLsuspensory in the absence of capsular intraocular lens implantation, suspensory ligament rupture caused by congenital dislocation of the lens, traumatic cataract and posterior capsular rupture without capsular support, which need to line hanging IOL for intraoperative clinical observation.METHODS: The 31 cases(32 eyeswho were accepted the four-fixable IOL suspensory from May 2012 to May 2014 in our hospital were retrospectively analyzed. The postoperative visual acuity, corneal astigmatism, intraoperative and postoperative complications were comprehensively analyzed.RESULTS: Patients were followed up 6mo~1a, corrected visual acuity >0.5(12 eyes, 38%, 0.1~0.5(18 eyes, 56%, and CONCLUSION: It is designed to support non-capsular IOL implantation and design, and the concept of changing the past presence of suspended dislocated IOL implantation surgery, positional deviation and, sutures and other complications split the incidence is greatly reduced. It is consistent with the physiological characteristics of the human eye, and it is the IOL surgical sling best stability, intraoperative and postoperative complications, the best visual acuity and corneal astigmatism minimal surgical approachat least, and the four-point suspension suture fixation of IOL is designed to obtain a practical transformation of Chinese patent.

  2. Intraocular lenses and clinical treatment in paediatric cataract

    Directory of Open Access Journals (Sweden)

    Camila Ribeiro Koch Pena

    2015-06-01

    Full Text Available Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should be individualized as well as correction with contact lens or spectacles. The intraocular lens single-piece hydrophobic acrylic are the most implanted in children and the preferably is in the capsular bag. The Sanders-Retzlaff-Kraff theoretic (SRK/T stressing that is described as more predictable, following Holladay I and SRK II and the recommendation is to under correction +6.0 or +8.0 dioptrias expecting the growth of the eye. The posterior capsule opacity is the most frequent complication and varies with the material choice of the lens. Glaucoma is the most serious postoperative complication and depends on the timing of the surgery, primary lens implantation and time of post surgical follow-up. The adherence to occlusion therapy with patching is critical to the visual prognosis and is determined by the child’s age and laterality of the cataract. There was significant improvement in the surgery and in IOLs, however the final visual prognosis is still not desirable.

  3. CT and MRI in progressive multifocal leukoencephalopathy

    International Nuclear Information System (INIS)

    Lanfermann, H.; Heindel, W.; Schroeder, R.; Lackner, K.

    1994-01-01

    Radiological findings and course of progressive multifocal leukoencephalopathy in 14 patients (1 woman, 13 men; 13 HIV seropositive, 1 chronic lymphatic leukaemia) were analysed retrospectively and correlated with clinical symptoms. A total of 21 CT and 16 MRI studies were evaluated. CT scans and MR images of 9 patients, which had been obtained in less than two weeks, could be compared to each other. MRI was superior to CT: 6 lesions with a diameter of 1 cm and below were not detected on CT scans, in 5 patients the extent of lesions was underestimated. Cortical involvement, mass effect or signs of atrophy were missing. Only 1 of 65 lesions showed a tiny enhancement after Gd injection. Due to the pattern and spread of lesions, which showed a close correlation to the neurologic symptoms, three different types of PML are suggested: 1. Initial precentral demyelinisation with contralateral hemiparesis (n=8); 2. lesions in temporo-occipital locations with visual disturbances (n=2); 3. predominantly bilateral lesions of cerebellar white matter with ataxia (n=4). (orig.) [de

  4. Cuerpo extraño intraocular en el segmento posterior Intraocular foreign bodies in the posterior segment

    Directory of Open Access Journals (Sweden)

    Diley Pérez García

    2012-01-01

    Full Text Available El trauma causado por cuerpo extraño intraocular es una de las principales causas de pérdida visual severa. Técnicamente es un trauma penetrante con permanencia del agente agresor dentro del globo ocular. Constituye una verdadera emergencia oftalmológica, pues puede ocasionar ceguera aún cuando se realiza un diagnóstico y tratamiento adecuados. Se realizó esta revisión para proponer un algoritmo de trabajo con el propósito de maximizar la recuperación anatómica y funcional después de una lesión de este tipo. La conducta a seguir ante este paciente requiere un tratamiento guiado por la apreciación del mecanismo del daño, naturaleza, localización y tamaño del cuerpo extraño; los conocimientos y la disposición del equipamiento necesario para el tratamiento quirúrgico y los cuidados posoperatorios. Existe controversia en cuanto al momento de extracción del cuerpo extraño; sin embargo, se debe realizar una conducta. La profilaxis de la endoftalmitis con antibióticos sistémicos es recomendada y la intravítrea de antibiótico debe ser considerada en los pacientes de alto riesgo. Se debe realizar el diagnóstico precoz o detección posoperatoria temprana de complicaciones como el desprendimiento de retina, endoftalmitis y la proliferación vítreorretiniana, que se han asociado con un pobre pronóstico visual.Intraocular foreign bodies are a major cause for severe visual loss. By technical definition, it consists of a form of penetrating ocular trauma, characterized by the persistence of the traumatic agent inside the eye, and is considered an ophthalmic emergency, since it may cause blindness even if good diagnosis and treatment are followed. This review was made to submit a management algorithm that can maximize the anatomical and functional outcomes after this type of injury. The management of these patients requires taking into account the mechanism of eye injury, the nature, the location and the size of the foreign body

  5. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-06-01

    Full Text Available Mun Yueh Faria,1 Nuno Ferreira,2 Eliana Neto,1 1Vitreo Retinal Department, 2Ophthalmology Department, Santa Maria Hospital, Lisbon, Portugal Objective: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL in ectopia lentis in Marfan syndrome (MFS. Design: Retrospective study. Methods: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA, and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years. Results: The average follow-up period was 6.66 months (range: 4–16 months. Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was –0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg and 16 mmHg (range: 12–18 mmHg, respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm, as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that

  6. The Effect of Altitude on Intraocular Pressure in Vitrectomized Eyes with Sulfur Hexafluoride Tamponade by the Friedenwald Method: Rabbit Animal Model

    Directory of Open Access Journals (Sweden)

    Jans Fromow-Guerra

    2016-01-01

    Full Text Available The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air. A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit’s scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m. There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.

  7. Progressive multifocal leucoencephalopathy in a patient with idiopathic CD4+ lymphocytopenia.

    LENUS (Irish Health Repository)

    Moloney, F

    2012-03-01

    Progressive multifocal leucoencephalopathy (PML) is an opportunistic, demyelinating neurological disease caused by reactivation of the JC polyomavirus. PML occurs almost exclusively in immunosuppressed individuals, with only isolated case reports of PML occurring in patients without apparent immunosuppression. Idiopathic CD4+ lymohocytopenia (ICL) is a syndrome defined by the Centre for Disease Control and Prevention as a CD4+ count <300 cells\\/uL or <20% of total T cell count on >1 occasion, with no evidence of human immunodeficiency virus (HIV) infection, and the absence of other known immunodeficiency or therapy associated with lymphocytopenia. We describe a case of PML occurring in a patient with idiopathic CD4+ lymphocytopenia.

  8. Pharmacokinetics and efficacy of intraocular flurbiprofen.

    Science.gov (United States)

    Blazaki, S; Tsika, C; Tzatzarakis, M; Naoumidi, E; Tsatsakis, A; Tsatsanis, C; Tsilimbaris, Miltiadis K

    2017-12-01

    Intravitreal delivery of non-steroidal anti-inflammatory drugs could be an effective way to treat macular edema caused by posterior segment inflammation. In this study, we evaluated the intravitreal bioavailability and anti-inflammatory efficacy of flurbiprofen in rabbit eyes. For pharmacokinetics, 0.1 ml of 7.66 mg/ml flurbiprofen solution was injected intravitreally and vitreous drug levels were analyzed at specific time points using LC-MS technique. For efficacy, 100 ng lipopolysaccharide of E.coli was injected intravitreally in rabbits to induce inflammation. The animals were separated in three groups and received intraocular flurbiprofen, dexamethasone and PBS to serve as control. Complete ocular examination and total cell count in aqueous fluid were determined to evaluate the extent of inflammation. Eyes were then enucleated for histopathology analysis. The efficacy in the uveitis model was determined by clinical signs of inflammation, total leukocyte count and histology findings. No adverse events were observed during pharmacokinetic assessment. No signs of inflammation, hemorrhage or retina detachment were detected. The recovery of flurbiprofen from vitreous samples was 92.6%. The half-life of flurbiprofen was estimated to be 1.92 h with an elimination constant rate (K) of 0.36. Treatment with intraocular injections of flurbiprofen and dexamethasone significantly reduced total leukocyte count in a manner comparable to dexamethasone [reduction of 96.84% (p flurbiprofen injection compared to control eyes. Flurbiprofen is effective in suppressing inflammation in this experimental uveitis model. In our experimental setting, intravitreal flurbiprofen seem to have a therapeutic result comparable to dexamethasone. However, the half-life of the drug remains short, necessitating further research to prolong its presence in the vitreous cavity.

  9. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  10. Fixation stability and implication for multifocal electroretinography in patients with neovascular age-related macular degeneration after anti-VEGF treatment

    DEFF Research Database (Denmark)

    Pedersen, Karen Bjerg; Sjølie, Anne Katrin; Vestergaard, Anders Højslet

    2016-01-01

    Purpose: To quantify fixation stability in patients with neovascular age-related macular degeneration (nAMD) at baseline, 3 and 6 months after anti-vascular endothelial growth factor (anti-VEGF) treatment and furthermore asses the implications of an unsteady fixation for multifocal...

  11. Review and update of intraocular therapy in noninfectious uveitis.

    Science.gov (United States)

    Sallam, Ahmed; Taylor, Simon R J; Lightman, Sue

    2011-11-01

    To review new clinically relevant data regarding the intraocular treatment of noninfectious uveitis. Triamcinolone acetonide, the most commonly used intravitreal corticosteroid for treatment of uveitis and uveitic macular oedema has a limited duration of action and is associated with a high risk of corticosteroid-induced intraocular pressure (IOP) rise and cataract. Recent advances have led to the development of sustained-release corticosteroid devices using different corticosteroids such as dexamethasone and fluocinolone acetonide. Treatment options for patients who have previously exhibited corticosteroid hypertensive response have also expanded through the use of new noncorticosteroid intravitreal therapeutics such as methotrexate and antivascular endothelial growth factor (anti-VEGF) agents. Ozurdex dexamethasone implant appears to have a better safety profile, and a slightly long-lasting effect than triamcinolone acetonide. The Retisert implant allows the release of corticosteroids at a constant rate for 2.5 years, but it requires surgical placement and its use is associated with a very high risk of cataract and requirement for IOP-lowering surgery. For patients who are steroid responders, methotrexate may offer a better alternative to corticosteroid treatment than anti-VEGF agents, but controlled trials are required to confirm this.

  12. MONTE CARLO SIMULATION OF MULTIFOCAL STOCHASTIC SCANNING SYSTEM

    Directory of Open Access Journals (Sweden)

    LIXIN LIU

    2014-01-01

    Full Text Available Multifocal multiphoton microscopy (MMM has greatly improved the utilization of excitation light and imaging speed due to parallel multiphoton excitation of the samples and simultaneous detection of the signals, which allows it to perform three-dimensional fast fluorescence imaging. Stochastic scanning can provide continuous, uniform and high-speed excitation of the sample, which makes it a suitable scanning scheme for MMM. In this paper, the graphical programming language — LabVIEW is used to achieve stochastic scanning of the two-dimensional galvo scanners by using white noise signals to control the x and y mirrors independently. Moreover, the stochastic scanning process is simulated by using Monte Carlo method. Our results show that MMM can avoid oversampling or subsampling in the scanning area and meet the requirements of uniform sampling by stochastically scanning the individual units of the N × N foci array. Therefore, continuous and uniform scanning in the whole field of view is implemented.

  13. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  14. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  15. Carcinoma superficial multifocal do pênis: ênfase ao teste do azul de toluidina

    Directory of Open Access Journals (Sweden)

    Hélio Begliomini

    Full Text Available The author reports a case of penile multifocal superficial carcinoma in a white 66 years old male. The lesions on glans penis and prepuce were asymptomatic. Their appearence were plain reddish ulceration, irregular margins which became evident after circumcision. There was no palpable groin lymph node. The toluidine blue test was useful for guiding biopsies. A partial penectomy was undertaken with free surgical margins of tumor. In a follow-up of two years, penil erectile function is preserve with no tumor recurrence.

  16. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  17. Mefloquine improved progressive multifocal leukoencephalopathy in a patient with systemic lupus erythematosus.

    Science.gov (United States)

    Beppu, Minako; Kawamoto, Michi; Nukuzuma, Souichi; Kohara, Nobuo

    2012-01-01

    We describe a case of a 67-year-old man with systemic lupus erythematosus who presented with progressive left hemiplegia. Although the cerebral spinal fluid (CSF) polymerase chain reaction (PCR) for the JC virus was negative, a brain biopsy confirmed the diagnosis of progressive multifocal leukoencephalopathy (PML). The tapering of prednisone and the use of cidofovir could not arrest the disease progression. Administration of mefloquine stopped the extension of the lesion, and resulted in obvious clinical improvement. The CSF nested PCR for the JC virus also became negative. This widely used drug should be tried for the treatment of non-HIV PML.

  18. High Resolution Depth-Resolved Imaging From Multi-Focal Images for Medical Ultrasound

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Dalgarno, Paul A.; Greenaway, Alan H.

    2015-01-01

    An ultrasound imaging technique providing subdiffraction limit axial resolution for point sources is proposed. It is based on simultaneously acquired multi-focal images of the same object, and on the image metric of sharpness. The sharpness is extracted by image data and presents higher values...... calibration curves combined with the use of a maximum-likelihood algorithm is then able to estimate, with high precision, the depth location of any emitter fron each single image. Estimated values are compared with the ground truth demonstrating that an accuracy of 28.6 µm (0.13λ) is achieved for a 4 mm depth...

  19. Progressive multifocal leukoencephalopathy restricted to the posterior fossa in a patient with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes; Lamb, Leslie; Del Carpio-O' Donovan, Raquel, E-mail: goncalves.neuroradio@gmail.com [McGill University Health Center Montreal General Hospital (Canada)

    2011-11-15

    Progressive multifocal leukoencephalopathy is a neurological infectious disease caused by the John Cunningham polyoma virus (JCV), an opportunistic agent with worldwide distribution. This disease is frequently seen in immunosuppressed patients and rarely associated with systemic lupus erythematosus. In the central nervous system PML demyelinating lesions occur in the supratentorial compartment. The authors describe a rare case of PML secondary to SLE treatment with atypical presentation restricted to the posterior fossa (author)

  20. Progressive multifocal leukoencephalopathy restricted to the posterior fossa in a patient with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Goncalves, Fabricio Guimaraes; Lamb, Leslie; Del Carpio-O'Donovan, Raquel

    2011-01-01

    Progressive multifocal leukoencephalopathy is a neurological infectious disease caused by the John Cunningham polyoma virus (JCV), an opportunistic agent with worldwide distribution. This disease is frequently seen in immunosuppressed patients and rarely associated with systemic lupus erythematosus. In the central nervous system PML demyelinating lesions occur in the supratentorial compartment. The authors describe a rare case of PML secondary to SLE treatment with atypical presentation restricted to the posterior fossa (author)

  1. Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.

    Science.gov (United States)

    Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N

    2018-01-01

    The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.

  2. Diffraction theory

    NARCIS (Netherlands)

    Bouwkamp, C.J.

    1954-01-01

    A critical review is presented of recent progress in classical diffraction theory. Both scalar and electromagnetic problems are discussed. The report may serve as an introduction to general diffraction theory although the main emphasis is on diffraction by plane obstacles. Various modifications of

  3. Common Genetic Determinants of Intraocular Pressure and Primary Open-Angle Glaucoma

    NARCIS (Netherlands)

    van Koolwijk, Leonieke M. E.; Ramdas, Wishal D.; Ikram, M. Kamran; Jansonius, Nomdo M.; Pasutto, Francesca; Hysi, Pirro G.; Macgregor, Stuart; Janssen, Sarah F.; Hewitt, Alex W.; Viswanathan, Ananth C.; ten Brink, Jacoline B.; Hosseini, S. Mohsen; Amin, Najaf; Despriet, Dominiek D. G.; Willemse-Assink, Jacqueline J. M.; Kramer, Rogier; Rivadeneira, Fernando; Struchalin, Maksim; Aulchenko, Yurii S.; Weisschuh, Nicole; Zenkel, Matthias; Mardin, Christian Y.; Gramer, Eugen; Welge-Luessen, Ulrich; Montgomery, Grant W.; Carbonaro, Francis; Young, Terri L.; Bellenguez, Celine; McGuffin, Peter; Foster, Paul J.; Topouzis, Fotis; Mitchell, Paul; Wang, Jie Jin; Wong, Tien Y.; Czudowska, Monika A.; Hofman, Albert; Uitterlinden, Andre G.; Wolfs, Roger C. W.; de Jong, Paulus T. V. M.; Oostra, Ben A.; Paterson, Andrew D.; Mackey, David A.; Bergen, Arthur A. B.; Reis, Andre; Hammond, Christopher J.; Vingerling, Johannes R.; Lemij, Hans G.; Klaver, Caroline C. W.; van Duijn, Cornelia M.

    2012-01-01

    Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4

  4. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  5. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  6. Role of cataract surgery in lowering intraocular pressure

    International Nuclear Information System (INIS)

    Ahmad, S.; Sabih, A.

    2015-01-01

    To study the effects of cataract surgery in lowering of intraocular pressure (IOP). Study Design: Retrospective study. Place and Duration of Study: The Department of Ophthalmology, Combined Military Hospital, Rawalpindi from January 2011 to December 2013. Patients and Methods: The study included a total of 250 patients; of which 100 cases had simple cataract with no coexisting disease, 100 cases had cataract with primary open angle glaucoma and 50 cases of cataract had accompanying pseudoexfoliation glaucoma. All patients were assessed and recorded preoperatively for their IOP, vision, depth of anterior chamber (ACD), angle of anterior chamber by gonioscopy and glaucoma medications being used. Cataract surgery was performed by phacoemulsification and IOL implantations in all cases. These patients were followed up for a period of six months. Results: The intraocular ressure of all these patients was recorded at monthly interval for six months. The IOP showed a significant decrease in all cases and remained constant till the end of the study. A marked improvement of vision was noted in all cases. The depth of the anterior chamber increased and the angle also widened in all cases. Discussion: Cataract surgery has been found to reduce IOP along with improvement in vision. Patients with glaucoma have a dual benefit of reduced IOP and visual improvement after cataract surgery. (author)

  7. In vitro study of antibiotic effect on bacterial adherence to acrylic intraocular lenses.

    Science.gov (United States)

    Gaál, Valéria; Kilár, Ferenc; Acs, Barnabás; Szijjártó, Zsuzsanna; Kocsis, Béla; Kustos, Ildikó

    2005-11-10

    Implantation of artificial intraocular lenses into the eye during ophthalmic surgical procedures ensures an unliving surface on which bacterial pathogens may attach and form biofilms. Despite antibiotic treatment bacteria growing in biofilms might cause inflammation and serious complications. In this study the adhesive ability of 7 Staphylococcus aureus and 11 coagulase-negative Staphylococcus (CNS) strains to the surface of acrylic intraocular lenses had been examined by the ultrasonic method. In untreated cases adhesion of the S. aureus and CNS strains did not differ significantly. We could not demonstrate significant differences between the adhesive ability of the standard strains and the clinical isolates. In this study a single--60 min long--antibiotic (ciprofloxacin and tobramycin) treatment had been applied, that correlate well with the single or intermittant antibiotic prophylaxis of patients. Ciprofloxacin administration was able to reduce significantly the number of attached cells on the surface of acrylic lenses both in the case of S. aureus and CNS strains. Dependence of the effect from concentration could also be demonstrated. Tobramycin treatment was able to inhibit significantly the attachment of S. aureus cells. Despite the debate on antibiotic prophylaxis we presented in our experiments that a single antibiotic administration can decrease the attachment of bacterial cells to the surface of acrylic intraocular lenses, and might be effective in the prevention of postoperative endophthalmitis, that is a rare but serious complication of ophthalmic surgery.

  8. Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

    Directory of Open Access Journals (Sweden)

    Flor Diana Yokoay Claros Chacaltana

    2016-01-01

    Full Text Available ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old, Group II (20 and 34 months and Group III (37 and 135 months. Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h. Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47±0.581mmHg, 2.47±0.581mmHg and 2.51±0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.

  9. Preliminary observation of refractive cataract surgery assisted by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Xiao-Li Wang

    2015-12-01

    Full Text Available AIM:To compare the differences of visual acuity and corneal astigmatism postoperatively between conventional refractive cataract surgery and that assisted by femtosecond laser.METHODS:Sixty patients(60 eyeswith age-related cataract and cornea astigmatism were divided into femtosecond group and conventional group randomly or voluntarily. The flat shaft, steep shaft and diopter of corneal astigmatism in patients in femtosecond group were inputted into the online vector calculators to get the location and width of the incision. Then femtosecond laser was used to make corneal releasing incision, the main and auxiliary incision. Phacoemulsification and aspheric multifocal intraocular lens implantation were undergone. Patients in conventional group received full-thickness relaxing incision by cornea paracentesis knife at the steepest meridian axis during phacoemulsification. Then aspheric multifocal intraocular lenses were implanted. Uncorrected distance visual acuity(UCDVA, uncorrected near visual acuity(UCNVAand cornea astigmatism were observed at 1d,1wk and 1mo postoperative. RESULTS:UCVA of patients in both groups was improved after the surgeries. UCDVA and UCNVA of femtosecond group were higher than those of conventional group, while the cornea astigmatism of femtosecond group was lower than that of conventional group.CONCLUSION:Refractile cataract surgery assisted by femtosecond laser canoffer better visual quality than conventional refractive cataract surgery because of lower cornea astigmatism and better visual acuity.

  10. IDIOPATHIC MULTIFOCAL CHOROIDITIS PRESENTING WITH A TRANSIENT PERIPAPILLARY WHITE RING.

    Science.gov (United States)

    Gattoussi, Sarra; Ghadiali, Quraish; Dolz-Marco, Rosa; Freund, K Bailey

    2017-11-22

    We describe with multimodal imaging the presentation and follow-up for a patient with idiopathic multifocal choroiditis and a transient peripapillary white ring. Case report. A 39-year-old Asian woman was initially seen for an evaluation of lattice degeneration in 2015. Her medical history included Graves disease and psoriasis. Best-corrected visual acuity was 20/25 in her right eye and 20/25 in her left eye. Ultra-widefield fundus autofluorescence imaging showed a curvilinear hyperautofluorescent line in her right eye. One year later, the patient returned complaining of floaters in her right eye for 1 month. Her visual acuity was unchanged. Funduscopic examination showed new inflammatory yellowish lesions in the right eye corresponding to hyperreflective sub-retinal pigment epithelium lesions on structural spectral domain optical coherence tomography. Fluorescein angiography showed corresponding late staining of these active lesions. Late-phase indocyanine green angiography showed multiple nummular hypocyanescent dots. Ultra-widefield fundus autofluorescence showed large areas of hyperautofluorescence. The patient was started on a 60-mg oral prednisone taper and demonstrated subsequent regression of the inflammatory lesions. Ten months later, the patient returned emergently with complaints of floaters in both eyes for 2 days and a new temporal scotoma in her left eye. Funduscopic examination demonstrated a white ring around the optic nerve of the left eye corresponding to a hyperautofluorescent lesion. Ultra-widefield fundus autofluorescence showed new areas of hyperautofluorescence in both eyes. Structural spectral domain optical coherence tomography showed new sub-retinal pigment epithelium inflammatory lesions and a disruption of the ellipsoid zone in both eyes. The patient was again treated with a 60-mg oral prednisone taper and demonstrated subsequent restoration of the ellipsoid zone. To our knowledge, this is the first report of a transient annular white

  11. Correlación entre la localización del lente intraocular, según biomicroscopia ultrasónica,y diferentes parámetros quirúrgicos en pacientes operados de catarata Correlation between the location of the intraocular lens according to ultrasonic biomicroscopy and several surgical parameters in patients operated from cataract

    Directory of Open Access Journals (Sweden)

    Eneida de la C Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Determinar la correlación entre la localización del lente intraocular en cámara posterior por biomicroscopia ultrasónica, diferentes parámetros quirúrgicos en pacientes operados de catarata. MÉTODOS: Se realizó un estudio descriptivo, prospectivo y transversal en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer», durante el período de enero a junio del 2007. Se estudiaron variables como: edad, sexo, etiología de la catarata, técnica quirúrgica, localización del lente intraocular según biomicroscopia ultrasónica, así como complicaciones transoperatorias y posoperatorias. RESULTADOS: El 79 % de todos los pacientes operados tenían entre 60 y 79 años de edad y algo más de la mitad correspondió al sexo femenino con un 59 %. La catarata senil fue la etiología que predominó con un 74 % y en el 68 % de los casos el lente se localizó por biomicroscopia ultrasónica en el saco capsular. En los ojos donde el lente intraocular se localizó fuera del saco, la proporción de complicaciones transoperatorias y posoperatorias fueron significativamente mayoritarias, mientras que en los ojos donde el lente intraocular se encontraba en el saco, la mayoría no presentó complicaciones transoperatorias ni posoperatorias. CONCLUSIONES: Las diferencias entre las distintas localizaciones del lente intraocular se encontraron con significación estadística en el tipo de catarata, la presencia de complicaciones transoperatorias y posoperatorias, sin embargo, no se encontró relación estadística significativa entre la localización del lente intraocular con la técnica quirúrgica utilizada.OBJECTIVE: To determine the correlation between the location of the intraocular lens in the posterior chamber using ultrasonic biomicroscopy and the different surgical parameters in patients operated from cataract. METHODS: A prospective, descriptive and cross-sectional study was carried out in "Ramón Pando Ferrer" Cuban Institute of

  12. Clinical study of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes

    Directory of Open Access Journals (Sweden)

    Ru-Fa Meng

    2015-07-01

    Full Text Available AIM: To investigate the operation methods and clinical effects of foldable intraocular lens secondary implantation after lens-vitrectomy in residual capsular with traumatic eyes.METHODS: During January 2012 to January 2014, foldable intraocular lens was implanted on 47 cases following lens-vitrectomy in residual capsular with traumatic eyes 3~6mo. Follow-up period was 6~12mo, averaged(8.21±2.63mo. RESULTS:All of 47 eyes had successful operation at one time, and position deviation was not appeared. The naked vision of the last postoperative follow-up was(0.44±0.19. Compared with best corrected visual acuity(0.41±0.23, and There was no significant difference between visual acuity of preoperative and last follow-up period(t=0.879, P=0.342. No severe complication was found. CONCLUSION: Secondary implantation of foldable intraocular lens is a safe and reliable method for correcting ametropia after lens-vitrectomy in residual capsular with traumatic eyes.

  13. Lessons learned: wrong intraocular lens.

    Science.gov (United States)

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Multifocal, recurrent malignant chondroid syringoma with visceral metastases: A case report and literature review

    Directory of Open Access Journals (Sweden)

    Ann Meredith Garcia

    2016-03-01

    Full Text Available We present the unusual case of malignant chondroid syringoma (MCS in a 64-year-old male with recurrent nodular skin lesions and visceral metastases. The patient underwent repeated excisions, with eventual development of widespread nodules and multiple pulmonary and hepatic nodules. Systemic chemotherapy was planned. MCS is a very rare skin adnexal tumor of the sweat glands with only around 50 cases reported worldwide. To the authors’ knowledge, this is the first reported case of MCS with a multifocal presentation and mucosal involvement.

  15. Could White Coat Ocular Hypertension Affect to the Accuracy of the Diagnosis of Glaucoma? Relationships Between Anxiety and Intraocular Pressure in a Simulated Clinical Setting.

    Science.gov (United States)

    Méndez-Ulrich, Jorge Luis; Sanz, Antoni; Feliu-Soler, Albert; Álvarez, María; Borràs, Xavier

    2018-03-01

    Sixty-one healthy subjects participated in a laboratory study carried out in a simulated clinical setting. Anticipatory anxiety-state was assessed at the arrival and immediately after, with no brief phase of adaptation, measurements of intraocular pressure, heart rate, systolic and diastolic blood pressure were collected. At the end of the procedure, anxiety-trait was also assessed. Results suggest that high levels of both anxiety-state and anxiety-trait significantly predicted a clinically relevant increase of intraocular pressure. Anxiety-state mediated the relationship between anxiety-trait and intraocular pressure, which also was found to be related with heart rate but not related to both systolic and diastolic blood pressure. These results suggest a common mechanism of regulation underlying anxiogenic variability found on both intraocular pressure and heart rate. A reduction in parasympathetic activity appears as a possible mechanism underlying to this phenomenon. This anxiety-enhanced intraocular pressure could be considered a phenomenon analogous to white coat hypertension found in the measurement of blood pressure; therefore, it probably should be taken into account in the clinical context to prevent errors in the diagnosis of glaucoma. Further research on cognitive and emotional regulation of intraocular pressure is needed to best characterize this hypothetical phenomenon.

  16. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  17. Compensating additional optical power in the central zone of a multifocal contact lens forminimization of the shrinkage error of the shell mold in the injection molding process.

    Science.gov (United States)

    Vu, Lien T; Chen, Chao-Chang A; Lee, Chia-Cheng; Yu, Chia-Wei

    2018-04-20

    This study aims to develop a compensating method to minimize the shrinkage error of the shell mold (SM) in the injection molding (IM) process to obtain uniform optical power in the central optical zone of soft axial symmetric multifocal contact lenses (CL). The Z-shrinkage error along the Z axis or axial axis of the anterior SM corresponding to the anterior surface of a dry contact lens in the IM process can be minimized by optimizing IM process parameters and then by compensating for additional (Add) powers in the central zone of the original lens design. First, the shrinkage error is minimized by optimizing three levels of four IM parameters, including mold temperature, injection velocity, packing pressure, and cooling time in 18 IM simulations based on an orthogonal array L 18 (2 1 ×3 4 ). Then, based on the Z-shrinkage error from IM simulation, three new contact lens designs are obtained by increasing the Add power in the central zone of the original multifocal CL design to compensate for the optical power errors. Results obtained from IM process simulations and the optical simulations show that the new CL design with 0.1 D increasing in Add power has the closest shrinkage profile to the original anterior SM profile with percentage of reduction in absolute Z-shrinkage error of 55% and more uniform power in the central zone than in the other two cases. Moreover, actual experiments of IM of SM for casting soft multifocal CLs have been performed. The final product of wet CLs has been completed for the original design and the new design. Results of the optical performance have verified the improvement of the compensated design of CLs. The feasibility of this compensating method has been proven based on the measurement results of the produced soft multifocal CLs of the new design. Results of this study can be further applied to predict or compensate for the total optical power errors of the soft multifocal CLs.

  18. Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.

    Science.gov (United States)

    Jürgens, Ignasi; Rey, Amanda

    2015-01-01

    We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Science.gov (United States)

    Kinoshita, Yuichi; Harada, Hiroshi; Kobayashi, Tadao K.; Yoshizawa, Katsuhiko; Yuri, Takashi; Takasu, Kosho; Tsubura, Airo; Shikata, Nobuaki

    2014-01-01

    Multifocal adenomatous oncocytic hyperplasia (MAOH) is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected. PMID:25580104

  20. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Directory of Open Access Journals (Sweden)

    Yuichi Kinoshita

    2014-12-01

    Full Text Available Multifocal adenomatous oncocytic hyperplasia (MAOH is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected.

  1. Progressive multifocal leukoence-phalopathy presenting as homonymous hemianopia in a patient with acquired immunodeficiency syndrome

    Directory of Open Access Journals (Sweden)

    Amit Pandey

    2012-01-01

    Full Text Available We present a case of a Human Immunodeficiency Virus (HIV positive patient who was referred for retinal evaluation to rule out ophthalmic manifestations of Acquired Immunodeficiency Syndrome (AIDS. She complained of some disturbance in vision in both eyes. Fundus examination showed no abnormality. Perimetry, done to rule out optic nerve pathology, showed a left homonymous hemianopia. Magnetic Resonance Imaging (MRI scan showed features of Progressive Multifocal Leukoencephalopathy (PML. She had no other neurological symptoms or signs.

  2. Prismatic displacement effect of progressive multifocal glasses on reaction time and accuracy in elderly people

    OpenAIRE

    Ellison, Ashton C; Campbell, A John; Robertson, M Clare; Sanderson, Gordon F

    2014-01-01

    Ashton C Ellison, A John Campbell, M Clare Robertson, Gordon F SandersonDunedin School of Medicine, Department of Medicine, Dunedin, New ZealandBackground: Multifocal glasses (bifocals, trifocals, and progressives) increase the risk of falling in elderly people, but how they do so is unclear. To explain why glasses with progressive addition lenses increase the risk of falls and whether this can be attributed to false projection, this study aimed to 1) map the prismatic displacement of a progr...

  3. Progressive multifocal leukoence--phalopathy presenting as homonymous hemianopia in a patient with acquired immunodeficiency syndrome.

    Science.gov (United States)

    Pandey, Amit; Bandivdekar, Karishma; Ramchandani, Suresh; Ramchandani, Sushama

    2012-01-01

    We present a case of a Human Immunodeficiency Virus (HIV) positive patient who was referred for retinal evaluation to rule out ophthalmic manifestations of Acquired Immunodeficiency Syndrome (AIDS). She complained of some disturbance in vision in both eyes. Fundus examination showed no abnormality. Perimetry, done to rule out optic nerve pathology, showed a left homonymous hemianopia. Magnetic Resonance Imaging (MRI) scan showed features of Progressive Multifocal Leukoencephalopathy (PML). She had no other neurological symptoms or signs.

  4. Subluxação congênita do cristalino: resultados visuais e posição das lentes intraoculares após a cirurgia Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position

    Directory of Open Access Journals (Sweden)

    Caroline Arraes

    2010-04-01

    Full Text Available OBJETIVO: Avaliar os resultados visuais e investigar, através da biomicroscopia ultrassônica, o posicionamento das lentes intraoculares e do anel endocapsular em 17 olhos de 10 portadores de subluxação congênita do cristalino, submetidos à mesma técnica cirúrgica pelo mesmo cirurgião. MÉTODOS: O estudo foi realizado no Hospital de Olhos de Pernambuco e Fundação Altino Ventura. A técnica cirúrgica consistiu em facoaspiração com implante de anel endocapsular e de lentes intraoculares com amputação de uma das alças. A idade variou entre 7 e 22 anos. Foram coletados dados sobre acuidade visual para longe pré e pós-operatória, tempo de seguimento após a cirurgia e complicações. Os pacientes foram submetidos à biomicroscopia ultrassônica. RESULTADOS: O tempo de seguimento médio foi de 2,8 anos. Houve melhora da acuidade visual para longe nos 17 (100% olhos: 12 olhos (70,6% apresentaram acuidade visual para longe melhor que 20/40; 4 (23,5% apresentaram acuidade visual para longe entre 20/40 e 20/100 e 1 (5,9% apresentou acuidade visual para longe pior que 20/100, porém melhor que acuidade visual para longe pré-operatória. A opacificação da cápsula posterior ocorreu em 10 olhos (58,9%. Na biomicroscopia ultrassônica observou-se que todas as lentes intraoculares estavam parcialmente descentralizadas, contudo sem atingir o bordo pupilar. Em todos os casos observou-se um adequado posicionamento do anel e um bom suporte capsular. CONCLUSÃO É possível concluir que o tratamento cirúrgico avaliado proporciona uma boa centralização das lentes intraoculares e do anel endocapsular, com melhora da acuidade visual para longe, sendo uma opção viável, eficaz e segura na reabilitação visual dos pacientes com subluxação congênita do cristalino.PURPOSE: To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients

  5. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  6. LONG-TERM INTRAOCULAR PRESSURE AFTER UNCOMPLICATED PARS PLANA VITRECTOMY FOR IDIOPATHIC EPIRETINAL MEMBRANE.

    Science.gov (United States)

    Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara

    2017-11-16

    To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.

  7. TBC1D24 Mutations in a Sibship with Multifocal Polymyoclonus

    Directory of Open Access Journals (Sweden)

    Adeline Ngoh

    2017-04-01

    Full Text Available Background: Advances in molecular genetic technologies have improved our understanding of genetic causes of rare neurological disorders with features of myoclonus.Case Report: A family with two affected siblings, presenting with multifocal polymyoclonus and neurodevelopmental delay, was recruited for whole-exome sequencing following unyielding diagnostic neurometabolic investigations. Compound heterozygous mutations in TBC1D24, a gene previously associated with various epilepsy phenotypes and hearing loss, were identified in both siblings. The mutations included a missense change c.457G>A (p.Glu157Lys, and a novel frameshift mutation c.545del (p.Thr182Serfs*6.Discussion: We propose that TBC1D24-related diseases should be in the differential diagnosis for children with polymyoclonus. 

  8. Intraocular lens subluxation in a patient with facial atopic dermatitis.

    Science.gov (United States)

    Yamazaki, S; Nakamura, K; Kurosaka, D

    2001-02-01

    A 66-year-old Japanese man presented with subluxation of a posterior chamber intraocular lens (IOL) caused by a rupture of part of Zinn's zonule but no retinal break 2 years after phacoemulsification with IOL implantation. He had a history of atopic dermatitis since infancy. This case presents a rare ocular complication of scratching and rubbing the face and eyelids because of itching related to atopic dermatitis.

  9. Intraocular pressure measurements after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Kumar, Vinod; Astyrakakis, Nikolaos I; Tsilimbaris, Miltiadis; Pallikaris, Ioannis G

    2005-01-01

    To determine the possible impact of conductive keratoplasty (CK) on intraocular pressure (IOP) measurements. A prospective, single-center, noncomparative interventional case series was performed. Baseline and postoperative IOPs were measured by Goldmann applanation tonometry in 32 eyes of 18 patients who underwent CK for hyperopia correction. Mean follow-up was 11.9 months (range: 8 to 18 months). After CK, a statistically significant decrease in the measured IOP was observed (before CK: 14.22+/-1.64 vs after CK: 12.66+/-2.21, P<.001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or attempted correction. Despite the limitations due to the small number of patients enrolled in this study, the applanation tonometer appears to underestimate the true IOP after CK.

  10. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    Science.gov (United States)

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p ultrasound, respectively (p power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  11. Net technique for intraocular lens support in aphakia without capsular support.

    Science.gov (United States)

    De Novelli, Fernando José; Neto, Theodomiro Lourenço Garrido; de Sena Rabelo, Gabriel; Blumer, Marcel Eduardo; Suzuki, Ricardo; Ghanem, Ramon Coral

    2017-01-01

    This paper describes a modified surgical technique for intraocular lens implantation in aphakic eyes with no capsular support. Retrospective case series. Seventeen eyes of 17 aphakic patients with no capsule support underwent intraocular lens (IOL) implantation using a standardized technique in which a net was created at the ciliary sulcus plane with two threads forming a net pattern. The net was used as support for the IOL. Follow-up ranged from 6 to 38 months, with an average of 23 months. In all cases, the IOL was safely implanted and remained stable during the follow-up. In 16 eyes, the IOL remained well centered; in one eye, slight decentration was observed. Distance-corrected visual acuity improved by a mean of 4 lines, from 1.13 (LogMAR) to 0.52 (P = 0.01). This technique might be especially useful in cases of insufficient capsular support associated with tissue loss or iris atrophy. In these cases, iris fixation is not feasible; thus, the only surgical alternative is IOL scleral fixation.

  12. Single suture iris-to-capsulorhexis fixation for in-the-bag intraocular lens subluxation.

    Science.gov (United States)

    Siegel, Michael J; Condon, Garry P

    2015-11-01

    We present a simplified modification to a technique for early or mild in-the-bag subluxation that avoids conjunctival and scleral incisions and minimizes intraocular manipulation. While the capsulorhexis edge is grasped with an intraocular forceps to stabilize the IOL-capsular bag complex, a 10-0 polypropylene suture on a long curved needle is used to secure the fibrotic superior capsulorhexis edge to the midperipheral iris at 12 o'clock using a combination of a modified McCannel suture and a Siepser sliding knot. Dr. Condon receives speaker and consultant fees from Alcon Surgical, Inc., Allergan, Inc., and Microsurgical Technology. Although the Microsurgical Technology Condon snare instrument is named after him, Dr. Condon reports no patents, fees, or payments related to it. Dr. Siegel has no financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  13. Bilateral Multifocal Hamartoma of the Chest Wall in an Infant

    Science.gov (United States)

    Yilmaz, Erdem; Erol, Oguz Bulent; Pekcan, Melih; Gundogdu, Gokcen; Bilgic, Bilge; Gun, Feryal; Yekeler, Ensar

    2015-01-01

    Summary Background Hamartoma of the thoracic wall is a rare benign tumor that occurs in infancy and can be mistaken for a malignancy due to its clinical and imaging features. Hamartomas are extrapleural soft tissue lesions that cause rib expansion and destruction and appear on imaging as cystic areas with fluid levels and calcification. They can cause scoliosis, pressure on the neighboring lung parenchyma and mediastinal displacement. While conservative treatment is recommended in asymptomatic cases, growing lesions require surgical excision. Case Report In this report, we present the imaging findings in a 3-month-old infant that presented with a firm swelling in the chest wall and was histopathologically confirmed to have a bilateral multifocal hamartoma. Conclusions Radiological imaging methods are important for accurate diagnosis of this very rare condition that can be confused with a malignancy. PMID:26082822

  14. Diffractive optics and nanophotonics resolution below the diffraction limit

    CERN Document Server

    Minin, Igor

    2016-01-01

    In this book the authors present several examples of techniques used to overcome the Abby diffraction limit using flat and 3D diffractive optical elements, photonic crystal lenses, photonic jets, and surface plasmon diffractive optics. The structures discussed can be used in the microwave and THz range and also as scaled models for optical frequencies. Such nano-optical microlenses can be integrated, for example, into existing semiconductor heterostructure platforms for next-generation optoelectronic applications. Chapter 1 considers flat diffractive lenses and innovative 3D radiating structures including a conical millimeter-wave Fresnel zone plate (FZP) lens proposed for subwavelength focusing. In chapter 2 the subwavelength focusing properties of diffractive photonic crystal lenses are considered and it is shown that at least three different types of photonic crystal lens are possible.  With the aim of achieving subwavelength focusing, in chapter 3 an alternative mechanism to produce photonic jets at Tera...

  15. Clinical application of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract

    Directory of Open Access Journals (Sweden)

    Qing-Song Gao

    2018-02-01

    Full Text Available AIM:To evaluate the effect of femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract. METHODS: Totally 86 cases(106 eyesof patients with double cataract in our hospital from January 2016 to January 2017 were selected, including 49 cases(59 eyeswere set as the observation group(treated with femtosecond laser assisted phacoemulsification combined with triple-focus intraocular lens implantation, and 37 cases(47 eyeswere set as the control group(received traditional phacoemulsification combined with triple-focus intraocular lens implantation. Corneal endothelial cell density, cumulative dissipated energy(CDE, distant and near visual accommodation before and after operation were compared between the two groups, postoperative complications were observed. RESULTS: The preoperative corneal endothelial cell density of two groups had no significant difference(P>0.05. The corneal endothelial cell density of two groups significantly decreased at postoperative 1wk, with statistic significance within groups(PPPPPP>0.05. The incidence of glare and halo in the observation group was 10.2% and 8.5% in the control group, and are in the patients whose age was above 60 years old, there was no significant difference between the two groups(P>0.05. CONCLUSION: Femtosecond laser assisted cataract surgery combined with triple-focus intraocular lens implantation in the treatment of cataract can not only improve curative effect, but also provide high safety, while the adverse events including glare, halo and other adverse visual circumstances should be considered after triple-focus intraocular lens implantation.

  16. The Comparison of the Influence of Thiopental and Propofol on Intraocular Pressure during Induction of Anesthesia in Intubated Patients under Cataracct Surgery

    Directory of Open Access Journals (Sweden)

    Reza Sahraei

    2016-07-01

    Full Text Available The prevention of the increase of intraocular pressure and the further decrease of it during eye surgery has an impressive effect on the success of surgery. Some of the phases of the induction of anesthesia like laryngoscopy and tracheal intubation result in the increase of intraocular pressure and its consequences are dangerous for penetrating injuries of eyeball. The goal of this research is the comparison of the changes of intraocular pressure during the induction of anesthesia in completely same conditions by using thiopental and propofol and also the careful investigation of their influences on intraocular pressure in order to select the medicine that effectively decrease the intraocular pressure and prevent the increase of it after laryngoscopy and tracheal intubation. In this research, 88 patients were selected and they were randomly divided into 2 groups. In the beginning of the patients' anesthesia, both groups were preoxygenated and they simultaneously receive initial dose of atracurium (0/5 mg/kg and then initial dose of fentanyl (1-2 µg/Kg. After prescription of fentanyl, the induction of anesthesia in the first group was done withthiopental (4 mg/kg and in the second group with propofol (2/5 mg/kg and after that, atracurium intubation (0/7 mg/kg was prescribed. Intraocular pressure is measured in two phases before induction of anesthesia (with tetracaine eyedrop and 3 minutes after intubation (with schiotz tonometer and 3±0/75 degree of accuracy and by a person who is not aware of the kind of anesthesia. The patients are replicated in 2 experimental and control groups in terms of age and gender. The results of independent t-test show that there is no significant difference between 2 groups of thiopental and propofol in terms of systolic and diastolic blood pressure, heart beat and eye pressure before the induction of anesthesia (p-value>0,05. The results of independent t-test show that there is a significant difference between2

  17. Two cases of uveitis masquerade syndrome caused by bilateral intraocular large B-cell lymphoma

    Directory of Open Access Journals (Sweden)

    Jovanović Svetlana

    2013-01-01

    Full Text Available Introduction. Sometimes it is not easy to clinically recognize subtle differences between intraocular lymphoma and noninfectious uveitis. The most common lymphoma subtype involving the eye is B-cell lymphoma. Case report. We presented two patients aged 59 and 58 years with infiltration of the subretinal space with a large B-cell non-Hodgkin intraocular lymphoma. The patients originally had clinically masked syndrome in the form of intermediate uveitis. As it was a corticosteroid-resistant uveitis, we focused on the possible diagnosis of neoplastic causes of this syndrome. During hospitalization, the neurological symptoms emerged and multiple subretinal changes accompanied by yellowish white patches of retinal pigment epithelium with signs of vitritis, which made us suspect the intraocular lymphoma. Endocranial magnetic resonance imaging established tumorous infiltration in the region of the left hemisphere of the cerebellum. The histopathological finding confirmed the diagnosis of large B-cell non-Hodgkin lymphoma of risk moderate degree, immunoblast - centroblast cytological type. The other patient had clinical chronic uveitis accompanied by yellowish shaped white echographic changes of the retina and localized changes in the level of the subretina. The diagnosis of lymphoma was made by brain biopsy. Conclusion. Uveitis masquerade syndrome should be considered in all patients over 40 years with idiopathic steroid-resistant uveitis. Treatment begun on time can affect the course and improve the prognosis of uveitis masquerade syndrome (UMS and systemic disease.

  18. Multifocal epilepsy: the role of palliative resection - intractable frontal and occipital lobe epilepsy secondary to radiotherapy for acute lymphoblastic leukaemia.

    Science.gov (United States)

    Radhakrishnan, Ashalatha; Sithinamsuwan, Pasiri; Harvey, A Simon; Flanagan, Danny; Fitt, Gregory; Berlangieri, Sam; Jackson, Graeme D; Berkovic, Samuel F; Scheffer, Ingrid E

    2008-12-01

    Patients with multifocal epilepsy are often considered unsuitable for epilepsy surgery. We report an adolescent with intractable frontal and occipital lobe seizures, secondary to complications of treatment for acute lymphoblastic leukaemia as a young child. Chemotherapy and radiotherapy were complicated by bilateral, posterior leukoencephalopathy and later an acquired frontal cerebral cavernous malformation (CCM). Detailed electro-clinical and imaging studies showed multiple, frontal lobe seizures per day with less frequent and non-debilitating, simple, occipital lobe seizures. Focal resection of the frontal CCM abolished the socially-disabling seizures with resultant marked improvement in the patient's quality of life at 12 months. Careful analysis of the type and impact of focal seizures in the setting of multifocal epilepsy may demonstrate that one seizure type is more deleterious to quality of life and may be amenable to surgery. In this situation, the patient may benefit significantly from surgery to resect the more active epileptic focus.

  19. Associations with intraocular pressure across Europe: The European Eye Epidemiology (E-3) Consortium

    NARCIS (Netherlands)

    Khawaja, Anthony P.; Springelkamp, Henriët; Creuzot-Garcher, Catherine; Delcourt, Cécile; Hofman, Albert; Höhn, René; Iglesias, Adriana I.; Wolfs, Roger C. W.; Korobelnik, Jean-François; Silva, Rufino; Topouzis, Fotis; Williams, Katie M.; Bron, Alain M.; Buitendijk, Gabriëlle H. S.; Cachulo, Maria da Luz; Cougnard-Grégoire, Audrey; Dartigues, Jean-François; Hammond, Christopher J.; Pfeiffer, Norbert; Salonikiou, Angeliki; van Duijn, Cornelia M.; Vingerling, Johannes R.; Luben, Robert N.; Mirshahi, Alireza; Lamparter, Julia; Klaver, Caroline C. W.; Jansonius, Nomdo M.; Foster, Paul J.; Acar, Niyazi; Anastosopoulos, Eleftherios; Azuara-Blanco, Augusto; Bergen, Arthur; Bertelsen, Geir; Binquet, Christine; Bird, Alan; Brétillon, Lionel; Bron, Alain; Buitendijk, Gabrielle; Cachulo, Maria Luz; Chakravarthy, Usha; Chan, Michelle; Chang, Petrus; Colijn, Annemarie; Cumberland, Philippa; Cunha-Vaz, José; Daien, Vincent; Deak, Gabor; Delyfer, Marie-Noëlle; Hollander, Anneke den; Dietzel, Martha; Erke, Maja Gran; Fauser, Sascha; Finger, Robert; Fletcher, Astrid; Foster, Paul; Founti, Panayiota; Göbel, Arno; Gorgels, Theo; Grauslund, Jakob; Grus, Franz; Hammond, Christopher; Helmer, Catherine; Hense, Hans-Werner; Hermann, Manuel; Hoehn, René; Hogg, Ruth; Holz, Frank; Hoyng, Carel; Jansonius, Nomdo; Janssen, Sarah; Khawaja, Anthony; Klaver, Caroline; Le Goff, Mélanie; Leal, Sergio; Lechanteur, Yara; Lehtimäki, Terho; Lotery, Andrew; Leung, Irene; Mauschitz, Matthias; Merle, Bénédicte; Meyer Zu Westrup, Verena; Midena, Edoardo; Miotto, Stefania; Mohan-Saïd, Sadek; Muldrew, Alyson; Mueller, Michael; Nunes, Sandrina; Oexle, Konrad; Peto, Tunde; Piermarocchi, Stefano; Prokofyeva, Elena; Rahi, Jugnoo; Raitakari, Olli; Ribeiro, Luisa; Rougier, Marie-Bénédicte; Sahel, José; Salonikiou, Aggeliki; Sanchez, Clarisa; Schmitz-Valckenberg, Steffen; Schweitzer, Cédric; Segato, Tatiana; Shehata, Jasmin; Silvestri, Giuliana; Simader, Christian; Souied, Eric; Springelkamp, Henriet; Tapp, Robyn; Verhoeven, Virginie; Von Hanno, Therese; Vujosevic, Stela; Williams, Katie; Wolfram, Christian; Yip, Jennifer; Zerbib, Jennyfer; Zwiener, Isabella

    2016-01-01

    Raised intraocular pressure (IOP) is the most important risk factor for developing glaucoma, the second commonest cause of blindness globally. Understanding associations with IOP and variations in IOP between countries may teach us about mechanisms underlying glaucoma. We examined cross-sectional

  20. Multifocal multiphoton microscopy with adaptive optical correction

    Science.gov (United States)

    Coelho, Simao; Poland, Simon; Krstajic, Nikola; Li, David; Monypenny, James; Walker, Richard; Tyndall, David; Ng, Tony; Henderson, Robert; Ameer-Beg, Simon

    2013-02-01

    Fluorescence lifetime imaging microscopy (FLIM) is a well established approach for measuring dynamic signalling events inside living cells, including detection of protein-protein interactions. The improvement in optical penetration of infrared light compared with linear excitation due to Rayleigh scattering and low absorption have provided imaging depths of up to 1mm in brain tissue but significant image degradation occurs as samples distort (aberrate) the infrared excitation beam. Multiphoton time-correlated single photon counting (TCSPC) FLIM is a method for obtaining functional, high resolution images of biological structures. In order to achieve good statistical accuracy TCSPC typically requires long acquisition times. We report the development of a multifocal multiphoton microscope (MMM), titled MegaFLI. Beam parallelization performed via a 3D Gerchberg-Saxton (GS) algorithm using a Spatial Light Modulator (SLM), increases TCSPC count rate proportional to the number of beamlets produced. A weighted 3D GS algorithm is employed to improve homogeneity. An added benefit is the implementation of flexible and adaptive optical correction. Adaptive optics performed by means of Zernike polynomials are used to correct for system induced aberrations. Here we present results with significant improvement in throughput obtained using a novel complementary metal-oxide-semiconductor (CMOS) 1024 pixel single-photon avalanche diode (SPAD) array, opening the way to truly high-throughput FLIM.

  1. Chronic recurrent multifocal osteomyelitis: how to suggest this diagnosis?; L`osteite chronique recurrente multifocale. Un diagnostic qu`il faut savoir evoquer

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Martin, Ch. [UCL Cliniques Saint-Luc, Bruxelles (Belgium); Kurelovic, I.; Soler, C.; Geoffray, A. [Fondation Laval, 06 - Nice (France); Durckel, J. [Hopital Hautepierre, 67 - Strasbourg (France)

    1997-09-01

    Chronic recurrent multifocal osteomyelitis is a rare disorder that affects children and teenagers. Clinically, it is characterized by insidious onset of local swelling and pain in several metaphyses. A symmetric, recurrent and multifocal pattern is usual. Spinal involvement is possible. Inconstant association with a cutaneous affection (palmo-plantar pustulosis, acne fulminans, psoriasis), or less frequently with an inflammatory chronic gut disorder is described. Pathogenesis usually recognized is an enthesopathy. Enthesitis may progress to the osseous part of the enthese and produce an aseptic chronic osteomyelitis. Biopsy specimen with culture is certainly necessary to rule out bacterial osteomyelitis and bone tumor. It is particularly true when the bone lesion is isolated. Disease course is benign and self-limited. The clinical course is characterized by recurrences and remissions occurring for 6 to 10 years. Treatment based on non steroid anti-inflammatory drugs is usually effective. (authors). 17 refs.

  2. Recent decreasing frequency of enucleation for intraocular retinoblastoma in Upper Egypt

    International Nuclear Information System (INIS)

    Abdallh, A.M.

    2006-01-01

    To evaluate the efficacy of combined systematic chemotherapy (chemoreduction) and local ophthalmic therapy (LT) is preventing or delaying external beam radiotherapy (EBRT) and enucleation in patients with intraocular retinoblastoma. This was a prospective, nonrandomized, single-institution, clinical study. Twenty-eight patients (37 eyes) with newly diagnosed intraocular retinoblastoma were included in this study. Primary enucleation was performed for 7 eyes with advanced intraocular retinoblastoma at presentation before starting chemoreduction. Using Reese-Ellsworth (RE) staging for RB, the remaining 30 eyes were as follows: Two in group I, 3 in group II, 8 in group III, 7 in group IV, and 9 in group V. All the 30 eyes were initially treated with 6 cycles of chemoredution using vincristine, etoposide and carboplatin, repeated every three weeks. After total of 6 cycles, each tumor was re-evaluated decide on the next mode of therapy. In cases where the tumor was reduced enough, LT (Thermotherapy, or cryotherapy, but plaque radiotherapy was unavailable) was applied. In cases where the tumor was reduced but insufficient for LT, we added another 3 cycles of same regimen in some patients; or we performed chemotherapy (CTT) for others, according to size of the residual tumor. Eyes failed to respond to tochemorduction and LT, received EBRT or were enucleated. Following 6 cycles of chemoreduction, all tumors showed an initial regression, and all vitreous and subretinal seeds showed calcification or disappearance of most of them. Among the 30 eyes, 12 eyes achieved complete response (CR), and 18 eyes achieved partial response (PR). Only 7 eyes (stage I to III) showed sufficient reduction of tumor size for the LT to be applied for, for which, TTT (4 eyes), and cryotherapy (3 eyes) were performed. Chemotherapy (CTT) was performed for 9 patients (13 eyes, 15 tumors). At the end of follow-up period, 14 of the total 30 eyes (46.7%) could not be salvaged with chemoreduction and LT

  3. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  4. Combined Acute Haemolytic and Secondary Angle Closure Glaucoma following Spontaneous Intraocular Haemorrhages in a Patient on Warfarin

    Directory of Open Access Journals (Sweden)

    Walter Andreatta

    2016-11-01

    Full Text Available Background: To report the first described case of combined haemolytic and acute angle closure glaucoma secondary to spontaneous intraocular haemorrhages in a patient on excessive anticoagulation. To the best of our knowledge, this is the first case reported in the literature presenting with raised intraocular pressure due to both mechanisms. Case Description: A 90-year-old woman presented with acute pain and reduction in vision in the left eye. Her intraocular pressure (IOP was 55 mm Hg. There were red tinted blood cells in the anterior chamber giving it a reddish hue. The patient was known to have advanced wet macular degeneration. She was taking oral warfarin for atrial fibrillation. Her international normalised ratio (INR was 7.7. B-scan ultrasound of posterior segment showed vitreous and suprachoroidal haemorrhages. An ultrabiomicroscopic examination confirmed open angles. A diagnosis of haemolytic glaucoma secondary to intraocular haemorrhages was made. The IOP was controlled medically. Warfarin was withdrawn and oral vitamin K therapy was initiated leading to a rapid INR reduction. Three days later, her anterior chamber became progressively shallower causing a secondary acute angle closure which was managed medically. After 2 months, the left IOP was well-controlled without any medications and the eye was not inflamed. Her vision in that eye remained perception of light. Conclusion: Patients with suprachoroidal haemorrhages should be closely monitored as they might subsequently develop acute angle closure despite an initially open angle and well-controlled INR and IOP. Excessive anticoagulation needs to be prevented to minimise the risk of sight-threatening complications.

  5. Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma.

    Science.gov (United States)

    Ganekal, Sunil; Dorairaj, Syril; Jhanji, Vishal; Kudlu, Krishnaprasad

    2014-01-01

    To evaluate the effect of 0.125% verapamil and 0.5% diltiazem eye drops on intraocular pressure (IOP) in steroid-induced glaucoma in rabbit eyes. A total of 18 rabbits with steroid-induced glaucoma were divided into three groups (A, B and C; n = 6 each). Right eyes in groups A, B and C received 0.5% diltiazem, 0.125% verapamil and 0.5% timolol eye drops twice daily for 12 days, respectively; whereas, left eyes received distilled water. IOP was measured with Tono-pen XL at baseline, day 4, day 8, and day 12 of treatment. Both 0.5% diltiazem and 0.125% verapamil eye drops significantly reduced IOP compared to control eyes (p cite this article: Ganekal S, Dorairaj S, Jhanji V, Kudlu K. Effect of Topical Calcium Channel Blockers on Intraocular Pressure in Steroid-induced Glaucoma. J Current Glau Prac 2014;8(1):15-19.

  6. Mechanical properties of intra-ocular lenses

    Science.gov (United States)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  7. The effect of dimethyl fumarate (Tecfidera™) on lymphocyte counts: A potential contributor to progressive multifocal leukoencephalopathy risk.

    Science.gov (United States)

    Khatri, Bhupendra O; Garland, Jeffery; Berger, Joseph; Kramer, John; Sershon, Lisa; Olapo, Tayo; Sesing, Jean; Dukic, Mary; Rehn, Eileen

    2015-07-01

    Dimethyl fumarate (Tecfidera™) is an effective therapy for relapsing forms of multiple sclerosis (MS). Our study suggests that this drug may have immunosuppressive properties evidenced by significant sustained reduction in CD8 lymphocyte counts and, to a lesser extent, CD4 lymphocyte counts. This observation is relevant in light of the recent case of progressive multifocal leukoencephalopathy in a patient receiving this drug. Copyright © 2015. Published by Elsevier B.V.

  8. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  9. A Cerebellar Tremor in a Patient with Human Immunodeficiency Virus-1 Associated with Progressive Multifocal Leukoencephalopathy

    Directory of Open Access Journals (Sweden)

    Hee-Jin Kim

    2009-10-01

    Full Text Available Progressive multifocal leukoencephalopathy (PML is a demyelinating disease of the central nervous system (CNS caused by JC virus infection in oligodendrocytes, especially in patients with acquired immunodeficiency syndrome (AIDS. Movement disorders associated with PML are very rare. Here, we report a case of PML in an AIDS patient who presented with a cerebellar tremor, caused by lesions in the cerebellar outflow tract. A cerebellar tremor can be a rare clinical manifestation in patients with PML.

  10. A Cerebellar Tremor in a Patient with Human Immunodeficiency Virus-1 Associated with Progressive Multifocal Leukoencephalopathy

    Science.gov (United States)

    Kim, Hee-Jin; Lee, Jae-Jung; Lee, Phil Hyu

    2009-01-01

    Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease of the central nervous system (CNS) caused by JC virus infection in oligodendrocytes, especially in patients with acquired immunodeficiency syndrome (AIDS). Movement disorders associated with PML are very rare. Here, we report a case of PML in an AIDS patient who presented with a cerebellar tremor, caused by lesions in the cerebellar outflow tract. A cerebellar tremor can be a rare clinical manifestation in patients with PML. PMID:24868366

  11. Application of polymerase chain reaction to differentiate herpes simplex virus 1 and 2 serotypes in culture negative intraocular aspirates

    Directory of Open Access Journals (Sweden)

    Shyamal G

    2005-01-01

    Full Text Available Purpose: To standardize and apply a polymerase chain reaction (PCR on the glycoprotein D gene to differentiate Herpes simplex virus (HSV 1 & 2 serotypes in culture negative intraocular specimens. Methods: Twenty-one intraocular fluids collected from 19 patients were subjected to cultures for HSV and uniplex PCR (uPCR for DNA polymerase gene. To differentiate HSV serotypes, as 1 & 2, a seminested PCR (snPCR targeting the glycoprotein D gene was standardised and applied onto 21 intraocular fluids. The specificity of the snPCR was verified by application onto ATCC strains of HSV 1 and 2, clinical isolates and DNA sequencing of the amplified products. All specimens were also tested for the presence of cytomegalovirus (CMV and varicella zoster virus (VZV by nucleic acid amplification methods. Results: Four of the 21 intraocular fluids were positive for HSV by uPCR. snPCR detected HSV in three additional specimens (total of seven specimens, and identified three as HSV 1 and four as HSV 2. DNA sequencing of PCR products showed 100% homology with the standard strains of HSV 1 and 2 respectively. None of the samples were positive in culture. Among the other patients, CMV DNA was detected in two and VZV DNA in five others. Conclusions: The standardized snPCR can be applied directly onto the culture negative specimens for rapid differentiation of HSV serotypes.

  12. Diffractive interactions

    International Nuclear Information System (INIS)

    Del Duca, V.; Marage, P.

    1996-08-01

    The general framework of diffractive deep inelastic scattering is introduced and reports given in the session on diffractive interactions at the international workshop on deep-inelastic scattering and related phenomena, Rome, April 1996, are presented. (orig.)

  13. [To exercise caution in developing intraocular lens exchange].

    Science.gov (United States)

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  14. Management of subluxated capsular bag-fixated intraocular lenses using a capsular anchor

    NARCIS (Netherlands)

    Ton, Yokrat; Naftali, Modi; Lapid Gortzak, Ruth; Assia, Ehud I.

    2016-01-01

    We describe the use of the capsular anchor (AssiAnchor) to manage a subluxated intraocular lens (IOL) in the capsular bag. The anchor comprises 2 prongs that hold the anterior lens capsule and a central rod that is sutured to the scleral wall, enabling centration of the IOL-capsular bag complex. Six

  15. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  16. Study on the pathogenesis of transient intraocular pressure after laser iridectomy with Krypton laser combined with Q-switched Nd:YAG laser

    Directory of Open Access Journals (Sweden)

    Zhi-Juan Pei

    2017-12-01

    Full Text Available AIM: To study the pathogenesis of transient intraocular pressure(IOPafter laser iridectomy with Krypton laser combined with Q-switched Nd:YAG laser. METHODS: Totally 42 healthy rabbits(84 eyesprovided by the Animal Experimental Center of our hospital were selected, including 18 female rabbits, 24 male rabbits, average weight 2.24±0.31kg, and they were randomly divided into 6 groups, 7 rats in each group(14 eyes. We observed the change of intraocular pressure after laser iridectomy surgery at 20min, 2, 6, 18, 24h and the nitric oxide(NO, malondialdehyde(MDA, superoxide dismutase(SOD, 6-keto-prostaglandin(6-keto-PGF1αand nitric oxide synthase(NOScontent in aqueous. RESULTS: There was no significant difference in intraocular pressure, NO, NOS, SOD, MAD and 6-keto- PGF1α before operation(P>0.05. The intraocular pressure increased after operation, and the difference was statistically significant(PP>0.05. The levels of NO, NOS and SOD in the aqueous humor of the two groups decreased 20min, 2 and 6h after the operation(PP>0.05. The levels of MDA and 6-keto-prostaglandin in the aqueous humor increased after the operation, and the difference was statistically significant at 20min, 2 and 6h after operation(PP>0.05.CONCLUSION: The increase of transient intraocular pressure after laser iridectomy may relate to the increase of malondialdehyde, 6-keto-prostaglandin content and the decrease of superoxide dismutase and nitric oxide in the aqueous humor after operation.

  17. Extreme depth-of-field intraocular lenses

    Science.gov (United States)

    Baker, Kenneth M.

    1996-05-01

    A new technology brings the full aperture single vision pseudophakic eye's effective hyperfocal distance within the half-meter range. A modulated index IOL containing a subsurface zeroth order coherent microlenticular mosaic defined by an index gradient adds a normalizing function to the vergences or parallactic angles of incoming light rays subtended from field object points and redirects them, in the case of near-field images, to that of far-field images. Along with a scalar reduction of the IOL's linear focal range, this results in an extreme depth of field with a narrow depth of focus and avoids the focal split-up, halo, and inherent reduction in contrast of multifocal IOLs. A high microlenticular spatial frequency, which, while still retaining an anisotropic medium, results in a nearly total zeroth order propagation throughout the visible spectrum. The curved lens surfaces still provide most of the refractive power of the IOL, and the unique holographic fabrication technology is especially suitable not only for IOLs but also for contact lenses, artificial corneas, and miniature lens elements for cameras and other optical devices.

  18. Diffraction coherence in optics

    CERN Document Server

    Françon, M; Green, L L

    2013-01-01

    Diffraction: Coherence in Optics presents a detailed account of the course on Fraunhofer diffraction phenomena, studied at the Faculty of Science in Paris. The publication first elaborates on Huygens' principle and diffraction phenomena for a monochromatic point source and diffraction by an aperture of simple form. Discussions focus on diffraction at infinity and at a finite distance, simplified expressions for the field, calculation of the path difference, diffraction by a rectangular aperture, narrow slit, and circular aperture, and distribution of luminous flux in the airy spot. The book th

  19. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  20. Multifocal epithelial hyperplasia: A potentially precancerous disease? (Review)

    Science.gov (United States)

    BASCONES-MARTÍNEZ, A.; COK, S.; BASCONES-ILUNDÁIN, C.; ARIAS-HERRERA, S.; GOMEZ-FONT, R.; BASCONES-ILUNDÁIN, J.

    2012-01-01

    Multifocal epithelial hyperplasia (MEH), also known as Heck’s disease, manifests as a papulonodular lesion in the oral mucosa and has been associated with the human papillomavirus, a virus related to various precancerous diseases in the oral cavity. It has a predisposition for the female gender and for children. Although the majority of reported cases have been among American Indians and Eskimos, it has been described in multiple ethnic groups in various geographical locations. The objective of this review was to report on the clinical characteristics and epidemiology of MEH and its possible correlation with oral cancer. It is based on a search of articles in international journals published prior to April 2011, using the PubMed database and selecting articles related to the epidemiology and clinical characteristics of MEH. The review revealed a higher number of cases in individuals of American Indian origin and a predilection of the disease for the female gender and for patients between the 1st and 2nd decades of life. The most frequent lesion site was the lower lip. The disease has been associated with socio-economic and genetic factors, among others. No cases of malignant transformation have been reported. PMID:22740890