WorldWideScience

Sample records for diagnostic techniques and procedures

  1. New perineal injection technique for pudendal nerve infiltration in diagnostic and therapeutic procedures

    NARCIS (Netherlands)

    Weinschenk, Stefan; Hollmann, Markus W.; Strowitzki, Thomas

    2016-01-01

    Pudendal nerve injection is used as a diagnostic procedure in the vulvar region and for therapeutic purposes, such as in vulvodynia. Here, we provide a new, easy-to-perform perineal injection technique. We analyzed 105 perineal injections into the pudendal nerve with a local anesthetic (LA),

  2. Radiochemical procedures and techniques

    International Nuclear Information System (INIS)

    Flynn, K.

    1975-04-01

    A summary is presented of the radiochemical procedures and techniques currently in use by the Chemistry Division Nuclear Chemistry Group at Argonne National Laboratory for the analysis of radioactive samples. (U.S.)

  3. Diagnostic and corrective procedures for TL analysis using the pre-dose technique

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1985-01-01

    The high sensitivity of the pre-dose TL technique using fired quartz grains with relatively low doses makes it the only TL technique that is generally suitable for retrospective environmental dosimetry. The use of this technique for dose measurements of less than 0.2 Gy has been the focus of research at the Utah laboratory, while the extension of the useful range of the pre-dose technique to doses in excess of 5 Gy has been the aim of the Durham laboratory. Certain characteristics of the pre-dose phenomenon, if not properly diagnosed, can lead to erroneous dose estimates at both extremes. This paper describes the procedures used at both laboratories to diagnose such problems and recently developed methods for their circumvention. (author)

  4. Core calculational techniques and procedures

    International Nuclear Information System (INIS)

    Romano, J.J.

    1977-10-01

    Described are the procedures and techniques employed by B and W in core design analyses of power peaking, control rod worths, and reactivity coefficients. Major emphasis has been placed on current calculational tools and the most frequently performed calculations over the operating power range

  5. Neurological Diagnostic Tests and Procedures

    Science.gov (United States)

    ... and three-dimensional pictures of brain activity by measuring radioactive isotopes that are injected into the bloodstream. ... Legislative Updates Impact NINDS Contributions to Approved Therapies Strategic Plans & Evaluations Strategic Plans Program Evaluations Workforce Diversity ...

  6. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    Science.gov (United States)

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  7. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  8. Diagnostic techniques

    International Nuclear Information System (INIS)

    Berquist, T.H.; Bender, C.E.; James, E.M.; Brown, M.L.; McLeod, R.A.; Broderick, D.F.; Welch, T.J.

    1989-01-01

    Proper application of imaging procedures is essential to obtain needed information for diagnosis and therapy planning in patients with suspected foot and/or ankle pathology. This paper provides basic background data for the numerous imaging techniques

  9. Mammography: Technique and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kim, Chung Ja; Bahk, Yong Whee; Lee, Don Young

    1974-01-01

    Mammography is now in world wide use, But this has received rather scanty attention in Korea. The purposes of the present communication are twofold: (1) Detailing of technical and photographic aspects of mam in ography and (2) an assessment of its diagnostic accuracy as experienced by us. The clinical materials consisted of 88 cases of mammography performed at the Department of Radiology, St. Mary's Hospital, Catholic Medical College during the 2 years-period from April 1972. We used nonscreen type mammographic or industrial fine- grain films, and a special mammographic device that can be attached to any of the ordinary radiographic machine. Technical factors are shown in Table II. Of 88 cases 19 were operated on or biopsied. There were 7 cases of carcinoma. 8 cases of inflammatory diseases, and 4 cases of benign tumor. Mammographic diagnosis was correct in 85.7% of carcinoma and 87.5% of inflammatory diseases. One misdiagnosis of 7 cases of carcinoma was turned out to be cystosarcoma phylloides. Of 4 cases of benign tumors 2 were correctly diagnosed, and the other 2 mistaken for either inflammatory disease or simple lactating breast. However, none of the benign conditions were diagnosed as malignant process. We found that nonscreen type mammographic or industrial fine-grain films, and hand-processing were necessary in obtaining the mammograms of desirable quality

  10. Spectrum monitoring procedures and techniques

    Science.gov (United States)

    1990-07-01

    The first step towards operating an emitter on a test range is to contact the local frequency manager to establish a schedule. Since restricted radio frequency bands and operations are different at each test range location, most testing is accomplished by sharing the spectrum available with all range users. The telemetry bands in particular require spectrum activity scheduling. The objective is to resolve scheduling conflicts prior to operations. When two programs or projects request to use the same spectrum, their activity can be separated by quard bands, discrete frequencies, time, or operating locations (terrain masking). Priorities assigned to each program usually dictate which program will be scheduled first; however, use of priorities to schedule activities should be avoided and only considered as a last resort. When a scheduling conflict cannot be resolved using these techniques, it is brought to the attention of the responsible program managers. When scheduling activities involve other federal or nonfederal agencies, it is in the best interest of program managers to be as flexible as possible.

  11. Pericardiectomy as a diagnostic and therapeutic procedure.

    Science.gov (United States)

    Konik, Ewa; Geske, Jeffrey; Edwards, William; Gersh, Bernard

    2016-11-14

    A 70-year-old man presented with recent onset, predominantly right-sided heart failure. Echocardiogram demonstrated features of hypertensive heart disease and was suggestive of, but non-diagnostic for, constrictive pericarditis (CP). CT demonstrated mild pericardial thickening. Right heart catheterisation showed elevation and equalisation of diastolic pressures in all cardiac chambers with early rapid filling, minimal ventricular interdependence, and no dissociation of intrathoracic and intracardiac pressures. While several features pointed towards CP, the minimal ventricular interdependence and no dissociation of intrathoracic and intracardiac pressures suggested other pathology. Diagnostic pericardiectomy was performed, after which the central venous pressure decreased from 22 to 12 mm Hg. Pathology revealed pericardial fibrosis. The patient experienced sustained resolution of his heart failure. A potential explanation for lack of CP criteria was the presence of hypertensive heart disease. CP needs to be considered when approaching patients with heart failure as diagnostic evaluation can be multifaceted and treatment curative. 2016 BMJ Publishing Group Ltd.

  12. [Causes, Diagnostic and Therapeutical Procedures of Malassimilation].

    Science.gov (United States)

    Schröder, Torsten; Kistenmacher, Alina; Smollich, Martin; Sina, Christian

    2018-05-01

    Patients with malassimilation suffer from disturbed exploitation of available nutrients, which can affect macro- and micronutrients. Malassimilation can be subdivided in maldigestion and malabsorption. Many different disorders, especially gastrointestinal diseases, can lead to malassimilation. The wide variety of differential diagnoses necessitates big diagnostic as well as financial efforts in order to assure good clinical care. This review provides an overview on diagnostic as well as therapeutic processes of patients with malassimilation and gives practical advice for their physicians and therapists. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Report on COTECH test procedure and characterization techniques

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    that need to be attained for successful characterization of the planned demonstrators and it deals with the material characterization and prototype testing for the COTECH demonstrators. The summary of this report includes:  General description of COTECH industrial demonstrators  COTECH materials...... and material characterization techniques  Characterization techniques of the COTECH demonstrators  Functionality and lifecycle testing of the COTECH demonstrators Besides the general introduction and conclusion each section of the report is dedicated to the characterization techniques and test procedure.......Characterization techniques and test procedure requirements for innovative self-ligating dental brackets (EO) Section 5.Characterization techniques and test procedure requirements for smart diagnostic chips comprising a microfluidic channel system (GBO) Section 6.Characterization techniques and test procedure...

  14. Prenatal diagnosis--principles of diagnostic procedures and genetic counseling.

    Directory of Open Access Journals (Sweden)

    Ryszard Slezak

    2008-04-01

    Full Text Available The frequency of inherited malformations as well as genetic disorders in newborns account for around 3-5%. These frequency is much higher in early stages of pregnancy, because serious malformations and genetic disorders usually lead to spontaneous abortion. Prenatal diagnosis allowed identification of malformations and/or some genetic syndromes in fetuses during the first trimester of pregnancy. Thereafter, taking into account the severity of the disorders the decision should be taken in regard of subsequent course of the pregnancy taking into account a possibilities of treatment, parent's acceptation of a handicapped child but also, in some cases the possibility of termination of the pregnancy. In prenatal testing, both screening and diagnostic procedures are included. Screening procedures such as first and second trimester biochemical and/or ultrasound screening, first trimester combined ultrasound/biochemical screening and integrated screening should be widely offered to pregnant women. However, interpretation of screening results requires awareness of both sensitivity and predictive value of these procedures. In prenatal diagnosis ultrasound/MRI searching as well as genetic procedures are offered to pregnant women. A variety of approaches for genetic prenatal analyses are now available, including preimplantation diagnosis, chorion villi sampling, amniocentesis, fetal blood sampling as well as promising experimental procedures (e.g. fetal cell and DNA isolation from maternal blood. An incredible progress in genetic methods opened new possibilities for valuable genetic diagnosis. Although karyotyping is widely accepted as golden standard, the discussion is ongoing throughout Europe concerning shifting to new genetic techniques which allow obtaining rapid results in prenatal diagnosis of aneuploidy (e.g. RAPID-FISH, MLPA, quantitative PCR.

  15. Outpatient invasive radiologic procedures - Diagnostic and therapeutic

    International Nuclear Information System (INIS)

    Dublin, A.

    1987-01-01

    This book is a ''how-to'' book for radiologists who are planning to, or considering whether to establish outpatient practice in response to DRGs. It provides practical, expert advice on both the administrative and clinical sides of outpatient radiology. It focuses on the essentials of clinical practice in the outpatient setting - and how it differs from inpatient practice

  16. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  17. Cumulative ionizing radiation during coronary diagnostic and interventional procedures

    International Nuclear Information System (INIS)

    Oyarzun C, Carlos; Ramirez, Alfredo

    2001-01-01

    The diagnostic ability of ionizing radiation is well known and has led to the development of high speed, high resolution axial tomography, for which we must assume that the patient population is being exposed to ionizing radiation that could become great. In cardiology, especially, we attend patients that have to undergo two or three angio graph, diagnostic and other therapeutic procedures, accumulating radiation doses that are ignored and are not recorded. The skin doses are shown that were received by 18 patients in procedures that included coronary angiography and that were measured with cesium thermoluminescent detectors, varying from 54 to 877 mSv. per procedure. We propose that a personal register be set up in Chile to record the magnitude of the radiation received by a patient (CO)

  18. Chipless RFID design procedure and detection techniques

    CERN Document Server

    Rezaiesarlak, Reza

    2015-01-01

    This book examines the design of chipless RFID systems. The authors begin with the historical development of wireless identification systems and finally arrive at a representation of the chipless RFID system as a block diagram illustration. Chapter 2 is devoted to the theoretical bases for the design of chipless RFID tags and detection techniques in the reader. A rigorous mathematical formulation is presented based on the singularity expansion method (SEM) and characteristic mode theory (CMT) in order to study the scattered fields from an object in a general form. Th e authors attempt to explain some physical concepts behind the mathematical descriptions of the theories in this chapter. In Chapter 3, two design procedures based on complex natural resonance and CMT are presented for the design of the chipless RFID tag. By studying the effects of structural parameters on radiation and resonant behaviors of the tag, some design conclusions are presented in this chapter. Chapter 4 is dedicated to the time-frequen...

  19. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  20. Diagnostic criteria and reporting procedures for pre-eclampsia

    DEFF Research Database (Denmark)

    Klemmensen, Ase K; Olsen, Sjurdur F.; Wengel, Christina M

    2005-01-01

    OBJECTIVE: A precondition for the rational use of obstetric databases in biomedical research is detailed knowledge on how data are being generated. We identified the diagnostic procedures and criteria for pre-eclampsia (PE) and assessed the level of obstetric training of the personnel responsible...... of pregnancy diagnoses to the National Patient Registry differed widely in training. For complicated pregnancies, departments ranged from having only specialists reporting all cases to secretaries reporting up to 50%. Cut off limits of blood pressure (BP) and protein loss used to diagnose pre-eclampsia showed...... large differences across departments. The diagnoses given to three case stories showed little correlation to the criteria the departments reported using. CONCLUSION: Even in a small country like Denmark with 34 obstetrical departments, there was little consensus on the diagnostic criteria for pre-eclampsia...

  1. Diagnostic techniques in deflagration and detonation studies.

    Science.gov (United States)

    Proud, William G; Williamson, David M; Field, John E; Walley, Stephen M

    2015-12-01

    Advances in experimental, high-speed techniques can be used to explore the processes occurring within energetic materials. This review describes techniques used to study a wide range of processes: hot-spot formation, ignition thresholds, deflagration, sensitivity and finally the detonation process. As this is a wide field the focus will be on small-scale experiments and quantitative studies. It is important that such studies are linked to predictive models, which inform the experimental design process. The stimuli range includes, thermal ignition, drop-weight, Hopkinson Bar and Plate Impact studies. Studies made with inert simulants are also included as these are important in differentiating between reactive response and purely mechanical behaviour.

  2. Bronchoscopic diagnostic procedures and microbiological examinations in proving endobronchial tuberculosis

    Directory of Open Access Journals (Sweden)

    Abdullah Şimşek

    Full Text Available ABSTRACT Objective: To determine the proportional distribution of endobronchial tuberculosis (EBTB subtypes and to evaluate the types of bronchoscopic diagnostic procedures that can prove granulomatous inflammation. Methods: This was a retrospective study of 18 HIV-negative patients with biopsy-proven EBTB treated between 2010 and 2014. Results: The most common EBTB subtypes, as classified by the bronchoscopic features, were tumorous and granular (in 22.2% for both. Sputum smear microscopy was performed in 11 patients and was positive for AFB in 4 (36.3%. Sputum culture was also performed in 11 patients and was positive for Mycobacterium tuberculosis in 10 (90.9%. Smear microscopy of BAL fluid (BALF was performed in 16 patients and was positive for AFB in 10 (62.5%. Culture of BALF was also performed in 16 patients and was positive for M. tuberculosis in 15 (93.7%. Culture of BALF was positive for M. tuberculosis in 93.7% of the 16 patients tested. Among the 18 patients with EBTB, granulomatous inflammation was proven by the following bronchoscopic diagnostic procedures: bronchial mucosal biopsy, in 8 (44.4%; bronchial brushing, in 7 (38.8%; fine-needle aspiration biopsy, in 2 (11.1%; and BAL, in 2 (11.1%. Bronchial anthracofibrosis was observed in 5 (27.7% of the 18 cases evaluated. Conclusions: In our sample of EBTB patients, the most common subtypes were the tumorous and granular subtypes. We recommend that sputum samples and BALF samples be evaluated by smear microscopy for AFB and by culture for M. tuberculosis, which could increase the rates of early diagnosis of EBTB. We also recommend that bronchial brushing be employed together with other bronchoscopic diagnostic procedures in patients suspected of having EBTB.

  3. Current diagnostic procedures for diagnosing vertigo and dizziness

    Science.gov (United States)

    Walther, Leif Erik

    2017-01-01

    Vertigo is a multisensory syndrome that otolaryngologists are confronted with every day. With regard to the complex functions of the sense of orientation, vertigo is considered today as a disorder of the sense of direction, a disturbed spatial perception of the body. Beside the frequent classical syndromes for which vertigo is the leading symptom (e.g. positional vertigo, vestibular neuritis, Menière’s disease), vertigo may occur as main or accompanying symptom of a multitude of ENT-related diseases involving the inner ear. It also concerns for example acute and chronic viral or bacterial infections of the ear with serous or bacterial labyrinthitis, disorders due to injury (e.g. barotrauma, fracture of the oto-base, contusion of the labyrinth), chronic-inflammatory bone processes as well as inner ear affections in the perioperative course. In the last years, diagnostics of vertigo have experienced a paradigm shift due to new diagnostic possibilities. In the diagnostics of emergency cases, peripheral and central disorders of vertigo (acute vestibular syndrome) may be differentiated with simple algorithms. The introduction of modern vestibular test procedures (video head impulse test, vestibular evoked myogenic potentials) in the clinical practice led to new diagnostic options that for the first time allow a complex objective assessment of all components of the vestibular organ with relatively low effort. Combined with established methods, a frequency-specific assessment of the function of vestibular reflexes is possible. New classifications allow a clinically better differentiation of vertigo syndromes. Modern radiological procedures such as for example intratympanic gadolinium application for Menière’s disease with visualization of an endolymphatic hydrops also influence current medical standards. Recent methodical developments significantly contributed to the possibilities that nowadays vertigo can be better and more quickly clarified in particular in

  4. Comparing imaging procedures: techniques and examples. Gastroenterology

    International Nuclear Information System (INIS)

    Malmud, L.S.

    1982-01-01

    The distinct advantages of nuclear medicine procedures, in comparison to radiography, contrast studies, computerized tomography and ultrasound, are emphasized. Scintigraphic methods offer quantitative data regarding function which competing imaging modalities are unable to provide, and make them the studies of choice in the evaluation of gastrointestinal physiology and functional abnormalities

  5. Development of process diagnostic techniques for piping and equipment

    International Nuclear Information System (INIS)

    Yotsutsuji, Mitoshi

    1987-01-01

    The thing required for using the facilities composing a plant for a long period without anxiety is to quantitatively grasp the quantities of the present condition of the facilities and to take the necessary measures beforehand. For this purpose, the diagnostic techniques for quickly and accurately detect the quantities of the condition of facilities are necessary, and the development of process diagnostic techniques has been desired. The process diagnostic techniques mentioned here mean those for diagnosing the contamination, clogging and performance of towers, tanks, heat exchangers and others. Idemitsu Engineering Co. had developed a simplified diagnostic equipment for detecting the state of fouling in piping in 1982, which is the gamma ray transmission diagnosis named Scale Checker. By further improving it, the process diagnostic techniques for piping and equipment were developed. In this report, the course of development and examination, the principle of detection, the constitution and the examination of remodeling of the Scale Checker are reported. As the cases of process diagnosis in plant facilities, the diagnosis of the clogging in process piping and the diagnosis of the performance of a distillation tower were carried out. The contents of the diagnosis and the results of those cases are explained. (Kako, I.)

  6. [Costing nuclear medicine diagnostic procedures].

    Science.gov (United States)

    Markou, Pavlos

    2005-01-01

    To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges.

  7. Using Pattern Classification and Recognition Techniques for Diagnostic and Prediction

    Directory of Open Access Journals (Sweden)

    MORARIU, N.

    2007-04-01

    Full Text Available The paper presents some aspects regarding the joint use of classification and recognition techniques for the activity evolution diagnostication and prediction by means of a set of indexes. Starting from the indexes set there is defined a measure on the patterns set, measure representing a scalar value that characterizes the activity analyzed at each time moment. A pattern is defined by the values of the indexes set at a given time. Over the classes set obtained by means of the classification and recognition techniques is defined a relation that allows the representation of the evolution from negative evolution towards positive evolution. For the diagnostication and prediction the following tools are used: pattern recognition and multilayer perceptron. The data set used in experiments describes the pollution due to CO2 emission from the consumption of fuels in Europe. The paper also presents the REFORME software written by the authors and the results of the experiment obtained with this software.

  8. Adaptive techniques for diagnostics of vibrating structures

    International Nuclear Information System (INIS)

    Skormin, V.A.; Sankar, S.

    1983-01-01

    An adaptive diagnostic procedure for vibrating structures based on correspondence between current estimates of stiffness matrix and structure status is proposed. Procedure employs adaptive mathematical description of the vibrating structure in frequency domain, statistical techniques for detection and location of changes of structure properties, 'recognition' and prediction of defects. (orig.)

  9. Indications and new diagnostic techniques in micturating cystourethrographic studies

    International Nuclear Information System (INIS)

    Schuster, W.; Bruenger, J.

    1978-01-01

    Urological radiographic procedures on children are of great importance. The frequency of examinations is comparable to the number of Gl tract studies. In diagnosing chronically recurrent urinary tract infections, micturating cystourethrography is a valuable addition to excretory urography. Indications and performance of micturating cystourethrography at juvenile age are described. All measures reducing radiation exposure must be taken into consideration. New technological devices grant improved diagnostic information with a minimal radiation exposure for patients. (orig.) [de

  10. Bronchoscopic diagnostic procedures and microbiological examinations in proving endobronchial tuberculosis.

    Science.gov (United States)

    Şimşek, Abdullah; Yapıcı, İlhami; Babalık, Mesiha; Şimşek, Zekiye; Kolsuz, Mustafa

    2016-01-01

    To determine the proportional distribution of endobronchial tuberculosis (EBTB) subtypes and to evaluate the types of bronchoscopic diagnostic procedures that can prove granulomatous inflammation. This was a retrospective study of 18 HIV-negative patients with biopsy-proven EBTB treated between 2010 and 2014. The most common EBTB subtypes, as classified by the bronchoscopic features, were tumorous and granular (in 22.2% for both). Sputum smear microscopy was performed in 11 patients and was positive for AFB in 4 (36.3%). Sputum culture was also performed in 11 patients and was positive for Mycobacterium tuberculosis in 10 (90.9%). Smear microscopy of BAL fluid (BALF) was performed in 16 patients and was positive for AFB in 10 (62.5%). Culture of BALF was also performed in 16 patients and was positive for M. tuberculosis in 15 (93.7%). Culture of BALF was positive for M. tuberculosis in 93.7% of the 16 patients tested. Among the 18 patients with EBTB, granulomatous inflammation was proven by the following bronchoscopic diagnostic procedures: bronchial mucosal biopsy, in 8 (44.4%); bronchial brushing, in 7 (38.8%); fine-needle aspiration biopsy, in 2 (11.1%); and BAL, in 2 (11.1%). Bronchial anthracofibrosis was observed in 5 (27.7%) of the 18 cases evaluated. In our sample of EBTB patients, the most common subtypes were the tumorous and granular subtypes. We recommend that sputum samples and BALF samples be evaluated by smear microscopy for AFB and by culture for M. tuberculosis, which could increase the rates of early diagnosis of EBTB. We also recommend that bronchial brushing be employed together with other bronchoscopic diagnostic procedures in patients suspected of having EBTB. Determinar a distribuição proporcional dos subtipos de tuberculose endobrônquica (TBEB) e avaliar os tipos de procedimentos diagnósticos broncoscópicos que podem revelar inflamação granulomatosa. Este foi um estudo retrospectivo com 18 pacientes HIV negativos com TBEB comprovada

  11. Cyber fraud tactics, techniques and procedures

    CERN Document Server

    Howard, Rick

    2009-01-01

    Written and edited by known experts in the field, the content is indeed of high quality and very informative. The logical structure and writing style are excellent, which is a challenging task when there are so many contributors. The book is a must-read for several reader categories. I strongly recommend some of the technical chapters to advanced undergraduate and graduate computer science students. Law students can use the book to grasp the necessary technical background material for investigating cyber fraud. Finally, it is also for readers who wish to learn about the current state of

  12. Monte Carlo techniques in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Zaidi, H.

    2002-01-01

    Monte Carlo techniques have become one of the most popular tools in different areas of medical radiation physics following the development and subsequent implementation of powerful computing systems for clinical use. In particular, they have been extensively applied to simulate processes involving random behaviour and to quantify physical parameters that are difficult or even impossible to calculate analytically or to determine by experimental measurements. The use of the Monte Carlo method to simulate radiation transport turned out to be the most accurate means of predicting absorbed dose distributions and other quantities of interest in the radiation treatment of cancer patients using either external or radionuclide radiotherapy. The same trend has occurred for the estimation of the absorbed dose in diagnostic procedures using radionuclides. There is broad consensus in accepting that the earliest Monte Carlo calculations in medical radiation physics were made in the area of nuclear medicine, where the technique was used for dosimetry modelling and computations. Formalism and data based on Monte Carlo calculations, developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine, were published in a series of supplements to the Journal of Nuclear Medicine, the first one being released in 1968. Some of these pamphlets made extensive use of Monte Carlo calculations to derive specific absorbed fractions for electron and photon sources uniformly distributed in organs of mathematical phantoms. Interest in Monte Carlo-based dose calculations with β-emitters has been revived with the application of radiolabelled monoclonal antibodies to radioimmunotherapy. As a consequence of this generalized use, many questions are being raised primarily about the need and potential of Monte Carlo techniques, but also about how accurate it really is, what would it take to apply it clinically and make it available widely to the medical physics

  13. Imaging mammary diagnostics. Diagnostic techniques, archetypical findings, differential diagnostcs and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Heywang-Koebrunner, S.; Schreer, I.

    2008-01-01

    The book includes the following chapters: I. Methodology: anamnesis and interview; clinical evidence, mammography, sonography, magnetic resonance tomography, new imaging techniques (scintigraphy, PET), transcutaneous biopsy, pre-operative marking; II. phenotypes: normal mammary glands, mastopathics, cysts, benign tumors, inflammatory diseases, in-situ carcinomas, invasive carcinomas, lymphomas, other semi-malign and malign tumors, post-traumatic, post-surgical and post-therapeutic changes, skin changes, male mamma, screening, continuative diagnostics of screening evidence and problem solving for symptomatic patients

  14. LeRC rail accelerators: test designs and diagnostic techniques

    International Nuclear Information System (INIS)

    Zana, L.M.; Kerslake, W.R.; Sturman, J.C.; Wang, S.Y.; Terdan, F.F.

    1984-01-01

    The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. 15 references

  15. MR diagnostics after Ross procedure

    International Nuclear Information System (INIS)

    Steffens, J.C.; Link, J.; Harringer, W.; Haverich, A.; Heller, M.

    1996-01-01

    Purpose: To determine the ability of MRI to diagnose morphological and functional changes in patients after Ross procedure. Material and methods: During one year, 5 patients after Ross procedure were studied by MRI. T 1 -weighted spin-echo sequences in different orientations as well as cine sequences and a VENC-sequence were used. Results: In all patients the morphology including the postoperative changes could be visualised by MRI. The cine sequences provided functional information on valvular and ventricular function. VENC-MR yielded an exact quantification of the regurgitant fraction. Conclusion: MRI is capable of providing all important diagnostic information in patients after Ross procedure such as valvular and ventricular function and valvular and outflow tract morphology in a single examination. (orig.) [de

  16. Diagnostic CT and percutaneous procedures after pancreatic transplantation

    International Nuclear Information System (INIS)

    Letourneau, J.G.; Hunter, D.W.; Thompson, W.M.; Sutherland, D.E.R.

    1987-01-01

    CT evaluation of the abdomen and pelvis is of great value after pancreatic transplantation. The expected CT appearance after pancreas transportation with both enteric and bladder drainage of exocrine function are presented, as is the appearance of infected and ischemic grafts. The CT detection and CT- and US-guided percutaneous aspiration and drainage of abdominal fluid collections are described. At the authors' institution, such aspiration and drainage procedures have obviated transplant pancreatectomy or surgical abscess drainage in 29% of patients

  17. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  18. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  19. Radiation risk of diagnostical procedures

    International Nuclear Information System (INIS)

    Pohlit, W.

    1986-01-01

    The environmental radiation burden of man in Germany is about 1 mGy (Milligray) per year. This is, of course, also valid for children. Due to diagnostical procedures this burden is increased to about 1.3 mGy. The question arises wether this can be neglected, or important consequences have to be drawn. To give a clear answer, the action of ionizing radiation in living cells and in organisms is explained in detail. Many of the radiation actions at the DNA can soon be repaired by the cell, if the radiation dose was small. Some damage, however will remain irreparable for the cell and consequently leads to cell death, to mutations or to cell transformation. The number of these lesion increases or decreases linearily with radiation dose. Therefore, it must be expected that the risk of tumour induction is increased to above the normal background even by the smallest doses. This small but not negligible risk has to be compared with other risks of civilization or with other medical risks. But also the benefit and the efficacy of diagnostic procedures have to be considered. (orig./HSCH) [de

  20. Study on assembly techniques and procedures for ITER tokamak device

    International Nuclear Information System (INIS)

    Obara, Kenjiro; Kakudate, Satoshi; Shibanuma, Kiyoshi; Sago, Hiromi; Ue, Koichi; Shimizu, Katsusuke; Onozuka, Masanori

    2006-06-01

    The International Thermonuclear Experimental Reactor (ITER) tokamak is mainly composed of a doughnut-shaped vacuum vessel (VV), four types of superconducting coils such as toroidal field coils (TF coils) arranged around the VV, and in-vessel components, such as blanket and divertor. The dimensions and weight of the respective components are around a few ten-meters and several hundred-tons. In addition, the whole tokamak assembly, which are composed of these components, are roughly estimated, 26 m in diameter, 18 m in height and over 16,500 tons in total weight. On the other hand, as for positioning and assembly tolerances of the VV and the TF coil are required to be a high accuracy of ±3 mm in spite of large size and heavy weight. The assembly procedures and techniques of the ITER tokamak are therefore studied, taking account of the tolerance requirements as well as the configuration of the tokamak with large size and heavy weight. Based on the above backgrounds, the assembly procedures and techniques, which are able to assemble the tokamak with high accuracy, are described in the present report. The tokamak assembly operations are categorized into six work break down structures (WBS), i.e., (1) preparation for assembly operations, (2) sub-assembly of the 40deg sector composed of 40deg VV sector, two TF coils and thermal shield between VV and TF coil at the assembly hall, (3) completion of the doughnut-shaped tokamak assembly composed of nine 40deg sectors in the cryostat at the tokamak pit, (4) measurement of positioning and accuracy after the completion of the tokamak assembly, (5) installation of the ex-vessel components, and (6) installation of in-vessel components. In the present report, two assembly operations of (2) and (3) in the above six WBS, which are the most critical in the tokamak assembly, are mainly described. The report describes the following newly developed tokamak assembly procedures and techniques, jigs and tools for assembly and metrology

  1. Industrial applications of radioisotopes: techniques and procedures of (NTIS) Nuclear Techniques Industrial Service

    International Nuclear Information System (INIS)

    Smith, S.W.; Kruger, J.

    1985-06-01

    Radioisotope handling procedures followed by personnel of the Nuclear Techniques Industrial Service (NTIS) during the conduction of investigations in industry are described. Possible radiological implications as a result of the various measuring techniques and different types of plants are discussed. Conditions under which permanent authorization has been granted for the use of radioisotopes are mentioned

  2. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr.

    1991-01-01

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk [RR], 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays

  3. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    OpenAIRE

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map the position and velocity distribution of atoms in either ground hyperfine level inside the solenoid without any devices inside the solenoid. The technique reveals the optical pumping ef- fects, and shows in de...

  4. Calibration and verification of surface contamination meters --- Procedures and techniques

    International Nuclear Information System (INIS)

    Schuler, C; Butterweck, G.; Wernli, C.; Bochud, F.; Valley, J.-F.

    2007-03-01

    A standardised measurement procedure for surface contamination meters (SCM) is presented. The procedure aims at rendering surface contamination measurements to be simply and safely interpretable. Essential for the approach is the introduction and common use of the radionuclide specific quantity 'guideline value' specified in the Swiss Radiation Protection Ordinance as unit for the measurement of surface activity. The according radionuclide specific 'guideline value count rate' can be summarized as verification reference value for a group of radionuclides ('basis guideline value count rate'). The concept can be generalized for SCM of the same type or for SCM of different types using he same principle of detection. A SCM multi source calibration technique is applied for the determination of the instrument efficiency. Four different electron radiation energy regions, four different photon radiation energy regions and an alpha radiation energy region are represented by a set of calibration sources built according to ISO standard 8769-2. A guideline value count rate representing the activity per unit area of a surface contamination of one guideline value can be calculated for any radionuclide using instrument efficiency, radionuclide decay data, contamination source efficiency, guideline value averaging area (100 cm 2 ), and radionuclide specific guideline value. n this way, instrument responses for the evaluation of surface contaminations are obtained for radionuclides without available calibration sources as well as for short-Iived radionuclides, for which the continuous replacement of certified calibration sources can lead to unreasonable costs. SCM verification is based on surface emission rates of reference sources with an active area of 100 cm 2 . The verification for a given list of radionuclides is based on the radionuclide specific quantity guideline value count rate. Guideline value count rates for groups of radionuclides can be represented within the maximum

  5. Legal aspects of deaths associated with diagnostic and therapeutic procedures.

    Science.gov (United States)

    Puxon, M

    1984-01-01

    Informed voluntary consent in relation to the charge of assault and battery is examined. The full implication of informed consent is set out. The legal aspects of negligence is also examined in relation to obtaining consent and the possibility of a wrong diagnosis. Where reasonable doubt exist about the correctness of a diagnosis the position of a second opinion is discussed. Guidelines on the handling of errors in treatment and anaesthetic deaths in relation to negligence is clearly set out.

  6. Exposure from diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.; Isac, R.

    2002-01-01

    According to our last national study on population exposures from natural and artificial sources of ionizing radiation, 16% of overall annual collective effective dose represent the contribution of diagnostic medical exposures. Of this value, 92% is due to diagnostic X-ray examinations and only 8% arise from diagnostic nuclear medicine procedures. This small contribution to collective dose is mainly the result of their lower frequency compared to that of the X-ray examinations, doses delivered to patients being, on average, ten times higher. The purpose of this review was to reassess the population exposure from in vivo diagnostic nuclear medicine procedures and to evaluate the temporal trends of diagnostic usage of radiopharmaceuticals in Romania. The current survey is the third one conducted in the last decade. As in the previous ones (1990 and 1995), the contribution of the Radiation Hygiene Laboratories Network of the Ministry of Health and Family in collecting data from nuclear medicine departments in hospitals was very important

  7. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for radiology...

  8. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  9. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  10. IMPAIRED MOBILITY OF VOCAL FOLDS – DIAGNOSTIC PROCEDURES AND TREATMENT, part 2

    Directory of Open Access Journals (Sweden)

    Karlo Pintarić

    2015-09-01

    Full Text Available Paresis or paralysis of one or both vocal cords affects phonation, swallowing and breathing. The major cause for reduced mobility or even immobility is innervation damage, less often mechanical disorder.The main procedures in the diagnostics of disordered vocal fold mobility are indirect laryngoscopy and videoendostroboscopy. Different imaging techniques (especially computerized tomography are of great value in searching for a cause of the impaired mobility.In unilateral vocal fold immobility, the treatment is focused on the improvement of voice quality and the prevention of aspiration during swallowing. In bilateral paralysis, it is crucial to find a balance between effective breathing and sufficient voice quality. The treatment of unilateral paralysis is started with voice therapy and swallowing rehabilitation. If these procedures are not enough surgical treatment for the medialization of the paralyzed vocal fold is applied. In the case of breathing difficulties in bilateral vocal fold immobility there is a possibility of surgical lateralization of one or both folds or a surgical excision of a part or the entire vocal fold. Surgical reinnervation, functional electrostimulation of certain laryngeal muscles and gene therapy are developing treatment modalities.

  11. Exposure to rays and radiation hazards in connection with diagnostic X-ray procedures in children

    International Nuclear Information System (INIS)

    Protzer, K.

    1988-01-01

    In this study, figures and data about radiation exposures for diagnostic purposes are surveyed that were collected in connection with X-ray procedures in children. The data were sorted according to body regions and techniques required for their examination so as to permit separate analyses of procedures in the urogenital tract (intravenous urogramme, micturition cystourethrography), thorax (angiocardiogramme, thoractic aortogramme, examinations using cardiac catheters), gastrointestinal system (fluoroscopy and contrast-enhanced irrigoscopy), pelvis (survey radiography), skull (computed tomography) as well as in miscellaneous group of further origins. The second part of the report discusses the uncertainties surrounding the assessment of radiation hazards and indicated radiation doses. A formula is represented for the calculation of life-time reductions that can be applied to any type of cancer and embraces a number of factors like life expectancy at age X, the patient's age at the time of radiotherapy, the five-year-survival rate for the condition under investigation and the diseased organ. At the end of the study, some methods are pointed out that may be helpful in limiting radiation exposure. (KST) [de

  12. MRI-guided stereotactic neurosurgical procedures in a diagnostic MRI suite: Background and safe practice recommendations.

    Science.gov (United States)

    Larson, Paul S; Willie, Jon T; Vadivelu, Sudhakar; Azmi-Ghadimi, Hooman; Nichols, Amy; Fauerbach, Loretta Litz; Johnson, Helen Boehm; Graham, Denise

    2017-07-01

    The development of navigation technology facilitating MRI-guided stereotactic neurosurgery has enabled neurosurgeons to perform a variety of procedures ranging from deep brain stimulation to laser ablation entirely within an intraoperative or diagnostic MRI suite while having real-time visualization of brain anatomy. Prior to this technology, some of these procedures required multisite workflow patterns that presented significant risk to the patient during transport. For those facilities with access to this technology, safe practice guidelines exist only for procedures performed within an intraoperative MRI. There are currently no safe practice guidelines or parameters available for facilities looking to integrate this technology into practice in conventional MRI suites. Performing neurosurgical procedures in a diagnostic MRI suite does require precautionary measures. The relative novelty of technology and workflows for direct MRI-guided procedures requires consideration of safe practice recommendations, including those pertaining to infection control and magnet safety issues. This article proposes a framework of safe practice recommendations designed for assessing readiness and optimization of MRI-guided neurosurgical interventions in the diagnostic MRI suite in an effort to mitigate patient risk. The framework is based on existing clinical evidence, recommendations, and guidelines related to infection control and prevention, health care-associated infections, and magnet safety, as well as the clinical and practical experience of neurosurgeons utilizing this technology. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.

  13. Risk and safety requirements for diagnostic and therapeutic procedures in allergology

    DEFF Research Database (Denmark)

    Kowalski, Marek L; Ansotegui, Ignacio; Aberer, Werner

    2016-01-01

    One of the major concerns in the practice of allergy is related to the safety of procedures for the diagnosis and treatment of allergic disease. Management (diagnosis and treatment) of hypersensitivity disorders involves often intentional exposure to potentially allergenic substances (during skin...... attempted to present general requirements necessary to assure the safety of these procedures. Following review of available literature a group of allergy experts within the World Allergy Organization (WAO), representing various continents and areas of allergy expertise, presents this report on risk...... associated with diagnostic and therapeutic procedures in allergology and proposes a consensus on safety requirements for performing procedures in allergy offices. Optimal safety measures including appropriate location, type and required time of supervision, availability of safety equipment, access...

  14. Education and training in radiological protection for diagnostic and interventional procedures ICRP 113 in brief

    International Nuclear Information System (INIS)

    Salama, S.; Gomaa, M. A.; Alshoufi, J.H.

    2013-01-01

    The international commission on radiological protection (ICRP) is the primary body in protection against ionizing radiation. Among its latest publication is ICRP publication 113 e ducation and training in radiological protection for diagnostic and interventional procedures . This document introduces diagnostic and interventional medical procedures using ionizing radiations in deep details. The document is approved by the commission in October 2010 and translated into Arabic at December 2011. This work is a continuation of the efforts series to translate some of the most important of the radiological protection references into the Arabic; aiming to maximize the benefit. The previous translation include WHO handbook on indoor radon: a public health perspective, issued by world health organization 2009 and Radiation Protection in Medicine, ICRP Publication 105 2007 that translated into Arabic with support of Arab atomic energy authority at 2011.

  15. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  16. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  17. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    NARCIS (Netherlands)

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map

  18. Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal

    2016-01-01

    The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  19. Risk and safety requirements for diagnostic and therapeutic procedures in allergology: World Allergy Organization Statement

    Directory of Open Access Journals (Sweden)

    Marek L. Kowalski

    2016-10-01

    Full Text Available Abstract One of the major concerns in the practice of allergy is related to the safety of procedures for the diagnosis and treatment of allergic disease. Management (diagnosis and treatment of hypersensitivity disorders involves often intentional exposure to potentially allergenic substances (during skin testing, deliberate induction in the office of allergic symptoms to offending compounds (provocation tests or intentional application of potentially dangerous substances (allergy vaccine to sensitized patients. These situations may be associated with a significant risk of unwanted, excessive or even dangerous reactions, which in many instances cannot be completely avoided. However, adverse reactions can be minimized or even avoided if a physician is fully aware of potential risk and is prepared to appropriately handle the situation. Information on the risk of diagnostic and therapeutic procedures in allergic diseases has been accumulated in the medical literature for decades; however, except for allergen specific immunotherapy, it has never been presented in a systematic fashion. Up to now no single document addressed the risk of the most commonly used medical procedures in the allergy office nor attempted to present general requirements necessary to assure the safety of these procedures. Following review of available literature a group of allergy experts within the World Allergy Organization (WAO, representing various continents and areas of allergy expertise, presents this report on risk associated with diagnostic and therapeutic procedures in allergology and proposes a consensus on safety requirements for performing procedures in allergy offices. Optimal safety measures including appropriate location, type and required time of supervision, availability of safety equipment, access to specialized emergency services, etc. for various procedures have been recommended. This document should be useful for allergists with already established

  20. Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography

    Directory of Open Access Journals (Sweden)

    Vlahiotis A

    2018-03-01

    Full Text Available Anna Vlahiotis,1 Brian Griffin,2 A Thomas Stavros,3 Jay Margolis1 1Value Based Care, Outcomes Research, Truven Health Analytics, an IBM Company, Bethesda, MD USA; 2Value Based Care, Outcomes Research, Truven Health Analytics, an IBM Company, Newark, NJ, USA; 3Seno Medical Instruments, Inc., San Antonio, TX, USA Background: Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam.Objectives: To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures.Materials and methods: Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event, with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes.Results: The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients, 6,987,399 breast ultrasounds (42.4% of patients, and 1,585,856 biopsies (10.3% of patients. Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD costs for diagnostic mammograms of US$349 ($493, ultrasounds US$132 ($134, and biopsies US$1,938 ($2,343 contributed

  1. Renal diagnostic nuclear medicine procedures in progressive systemic scleroderma (PSS)

    Energy Technology Data Exchange (ETDEWEB)

    Ammari, B.; Hotze, A.; Gruenwald, F.; Biersack, H.J.; Blitz, H.; Kuester, W.; Kreysel, H.W.

    1989-02-01

    The involvement of kidneys in progressive systemic scleroderma (PSS) is one of the most frequent causes of death in this disease. Using clinical criteria and laboratory tests only the frequency of kidney involvement would be clearly underestimated. Invasive diagnostic procedures such as biopsy and angiography can not be applied in those patients. Nuclear medicine techniques (hippurate clearance, DMSA-scan), however, offer non invasive and sensitive methods in the diagnosis of renal involvement in PSS patients. In our study 46 of 76 patients (60%) revealed pathologic findings. The mentioned diagnostic techniques show a high sensitivity and are in agreement with pathological findings described in PSS.

  2. Renal diagnostic nuclear medicine procedures in progressive systemic scleroderma (PSS)

    International Nuclear Information System (INIS)

    Ammari, B.; Hotze, A.; Gruenwald, F.; Biersack, H.J.; Blitz, H.; Kuester, W.; Kreysel, H.W.

    1989-01-01

    The involvement of kidneys in progressive systemic scleroderma (PSS) is one of the most frequent causes of death in this disease. Using clinical criteria and laboratory tests only the frequency of kidney involvement would be clearly underestimated. Invasive diagnostic procedures such as biopsy and angiography can not be applied in those patients. Nuclear medicine techniques (hippurate clearance, DMSA-scan), however, offer non invasive and sensitive methods in the diagnosis of renal involvement in PSS patients. In our study 46 of 76 patients (60%) revealed pathologic findings. The mentioned diagnostic techniques show a high sensitivity and are in agreement with pathological findings described in PSS. (orig.) [de

  3. Pain related to cancer treatments and diagnostic procedures: a no man's land?

    Science.gov (United States)

    Ripamonti, C I; Bossi, P; Santini, D; Fallon, M

    2014-06-01

    While guidelines are available for the management of cancer-related pain, little attention is given to the assessment and treatment of pain caused by treatments and diagnostic procedures in cancer patients. We evaluated the literature on pain related to cancer treatment and diagnostic procedures within a critical analysis. The data available are sparse, suggesting that little attention has been directed at this important aspect of oncology. This points to potentially suboptimal patient management. Appropriate studies are necessary in order to understand the incidence and appropriate management of pain, both during and/or after oncological treatments and diagnostic procedures. At the same time, Health Care Professionals should have heightened awareness of the causes and treatment of pain with the aim of anticipating and managing pain most appropriately for each individual patient. This is clearly an important component of holistic patient care before, during, and after oncological treatment. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection

    Directory of Open Access Journals (Sweden)

    Adriana Vince,

    2010-02-01

    Full Text Available Clinical diagnostics of HPV infection is based on analytically andclinically validated assays for qualitative detection of HPV DNAfrom high risk genotypes. New generation of HPV DNA assayscombines qualitative detection of 12 high-risk HPV genotypeswith HPV-16 and HPV-18 genotyping. New generation of HPVmolecular assays designed to increase clinical specificity of moleculartesting is based on detection of mRNA for E6 and E7.

  5. Analysis of risk in computerized tomography and other diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Mossman, K.L.

    1982-01-01

    Medical practice entails continuous risks to the patient taken in good faith by the physician for the benefit of the patient. Risk of radiation induced cancer death approximates 10(-4) per cGy (rad). Assuming an average whole body dose of 0.1 cGy for many diagnostic X-ray procedures, the probability of radiation-induced cancer death is about 10(-5). The purpose of this paper is to compare the risks of common diagnostic X-ray procedures including computerized tomography (CT) with risks of smoking or automobile travel. Such comparisons should be constructive in putting radiation in perspective and facilitating explanation of risk/benefit to patients

  6. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  7. Arts and technology - Mosaic new techniques and procedures

    Science.gov (United States)

    Papiu, G. A.; Suciu, N.

    2017-05-01

    The relationship between art and technique has been along the time one that is inseparable and systematic, artists appealing to various technologies, tools and practices that help them stimulate their imagination. Today there is a new category of artists, coming from a technical or scientific field, that are being 'trapped’ in this ‘game of art”. The mosaic, even if it is an old technique, responded to the social requirements and it evolved over time, being constantly related to aesthetic and artistic thinking, discoveries of science, assimilating permanent new techniques and technologies, diversifying its artistic forms of expression and methods of transposition. Not being bound any more to a religious institution, which was its birth place, today, she migrated to all public spaces. Works of art in public space have become today an active factor in reshaping the urban aesthetic landscape.

  8. Diagnostic reference activities for nuclear medicine procedures in Australia and New Zealand

    International Nuclear Information System (INIS)

    Smart, R.C.; Towson, J.E.

    2000-01-01

    In July 1998 a survey of diagnostic nuclear medicine procedures in Australia and New Zealand was undertaken on behalf of the Australian and New Zealand Society of Nuclear Medicine (ANZSNM) and the Australasian Radiation Protection Society (ARPS) in order to establish diagnostic reference activities. A total of 96 responses were received representing 154 practices, comprising 45 public hospital departments, 21 private hospital departments, 87 private practices and 1 unspecified practice. The survey requested the usual activities administered for a standard adult, the method used to determine the activity for children and the minimum activities used for paediatric patients. Data was obtained for 80 different imaging procedures and for 17 non-imaging tracer studies. For those procedures for which information was available from 10 or more practices, 68 in total, the reference activity was calculated as the 75th percentile of the distribution of activities. The Most Common Activity, the Reference Activity, together with the effective dose in both male and female patients, is tabulated for all these procedures. Copyright (2000) Australasian Radiation Protection Society Inc

  9. Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: Experience at a single center

    International Nuclear Information System (INIS)

    Chun, Chang Woo; Kim, Bum Soo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong Sam

    2014-01-01

    To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 +/- 44.8 Gy-cm 2 , and 251 +/- 49 frames for diagnostic procedures, 52.9 minutes, 226.0 +/- 129.2 Gy-cm 2 , and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 +/- 184.6 Gy-cm 2 , and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm 2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 +/- 3.2 Gy-cm 2 . On average, rotational angiography was used 1.4 +/- 0.6 times/session (range, 1-4; n = 580). Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.

  10. European wind turbine procedure development blade test methods and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bulder, B H; Dam, J J.D. van; Delft, D R.V. van [and others

    1999-03-01

    In this paper the preliminary results obtained by performing the second task of the `European Wind Turbine Testing Procedure Development` project are presented. This project is performed within and with financial support of the Standards, Measurements and Testing programme of the European Commission. (au)

  11. Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Osei, Ernest K; Barnett, Rob

    2009-01-01

    Diagnostic radiological imaging such as conventional radiography, fluoroscopy and computed tomography (CT) examinations will continue to provide tremendous benefits in modern healthcare. The benefit derived by the patient should far outweigh the risk associated with a properly conducted imaging examination. Nonetheless, it is very important to be able to quantify the risk associated with any radiological examination of patients, and effective dose has been considered a useful indicator of patient exposure. Quantification of the risks associated with radiological imaging is very important as such information will be helpful to physicians and their patients for comparing risks from various imaging examinations and for making informed decisions whenever there is a need for any radiological imaging. The determination of equivalent and effective doses in diagnostic radiology is of interest as a basis for estimates of risk from medical exposures. In this paper we describe a simple computer program OrgDose, which calculates the doses to 27 organs in the body and then calculates the organ equivalent and effective doses and the risk from various procedures in the radiology department including conventional radiography, fluoroscopy and computed tomography examinations. The program will be a useful tool for the medical and paramedical personnel who are involved with assessing organ and effective doses and risks from diagnostic radiology procedures.

  12. Valve Calcification in Aortic Stenosis: Etiology and Diagnostic Imaging Techniques

    Directory of Open Access Journals (Sweden)

    María Manuela Izquierdo-Gómez

    2017-01-01

    Full Text Available Aortic stenosis is the most common valvulopathy in the Western world. Its prevalence has increased significantly in recent years due to population aging; hence, up to 8% of westerners above the age of 84 now have severe aortic stenosis (Lindroos et al., 1993. This causes increased morbidity and mortality and therein lies the importance of adequate diagnosis and stratification of the degree of severity which allows planning the best therapeutic option in each case. Long understood as a passive age-related degenerative process, it is now considered a rather more complex entity involving mechanisms and factors similar to those of atherosclerosis (Stewart et al., 1997. In this review, we summarize the pathophysiological mechanisms underlying the onset and progression of the disease and analyze the current role of cardiac imaging techniques for diagnosis.

  13. The radiopharmaceuticals in nuclear medicine diagnostic procedures and the problem of radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Ftacnikova, S [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    In this paper equivalent dose from Auger electron emitters was reevaluated. The presented approach represents a practical step toward the estimation of equivalent dose for incorporated Auger electron emitters, an aspects that has not been given adequate consideration so far. Given the widespread use of this class of radionuclides in nuclear medicine and in biomedical research, the formalism and practical calculation presented here may be of value to assessing the risk associated with this radionuclides (in diagnostic nuclear medicine procedures), as well as predicting their therapeutic efficiency. (J.K.) 2 tabs., 11 refs.

  14. Diagnostical Procedure for Logistical Management in Turistical Entities

    Directory of Open Access Journals (Sweden)

    Libia Arlen Fergusson-Álvarez

    2016-06-01

    Full Text Available This research aims to design a diagnostic procedure of the logistics management for turistical entities, they could be hotels or not. This procedure was validated in Commercial Branch Caracol Santiago de Cuba and finally, different actions for the detected problems were proposed with the objective of improving the logistics management of the organization. To develop this research various tools and techniques served as support, such as: surveys, SPSS software (Statistical Package for Social Sciences 15.0 version and Decision 1.0 version, exponential smoothing, Cronbach's Alpha, the coefficient of Kendall W, financial and logistical indicators, the ABC or Pareto Method, the matrices for the classification of stocks and suppliers, among others. This research made possible the design of a diagnostic procedure for logistical management for turistical entities. And it was validated in the Comercial Branch Caracol Santiago, which allowed the proposition of improvement actions for increasing customer satisfaction.

  15. Costs, charges, and revenues for hospital diagnostic imaging procedures: differences by modality and hospital characteristics.

    Science.gov (United States)

    Sistrom, Christopher Lee; McKay, Niccie L

    2005-06-01

    This study examined financial data reported by Florida hospitals concerning costs, charges, and revenues related to imaging services. Financial reports to the Florida Hospital Uniform Reporting System by all licensed acute care facilities for fiscal year 2002 were used to calculate four financial indices on a per procedure basis. These included charge, net revenue, operating expense (variable cost), and contribution margin. Analysis, stratified by cost center (imaging modality), tested the effects of bed size, ownership, teaching status, and urban or rural status on the four indices. The mean operating expense and charge per procedure were as follows: computed tomography (CT): $51 and $1565; x-ray and ultrasound: $55 and $410; nuclear medicine (NM): $135 and $1138; and magnetic resonance imaging (MRI): $165 and $2048. With all four modalities, for-profit hospitals had higher charges than not-for-profit and public facilities. Excepting NM, however, the difference by ownership disappeared when considering net revenue. Operating expense did not differ by ownership type or bed size. Operating expense (variable cost) per procedure is considerably lower for CT than for MRI. Consequently, when diagnostically equivalent, CT is preferable to MRI in terms of costs for hospitals. If the cost structure of nonhospital imaging is at all similar to hospitals, the profit potential for performing CT and MRI seems to be substantial, which has relevance to the issue of imaging self-referral.

  16. Diagnostic techniques for viroids

    Czech Academy of Sciences Publication Activity Database

    Gucek, T.; Trdan, S.; Jakše, J.; Javornik, B.; Matoušek, Jaroslav; Radisek, S.

    2017-01-01

    Roč. 66, č. 3 (2017), s. 339-358 ISSN 0032-0862 Institutional support: RVO:60077344 Keywords : potato-spindle-tuber * multiplex rt-pcr * mediated isothermal amplification Subject RIV: EE - Microbiology, Virology OBOR OECD: Biochemistry and molecular biology Impact factor: 2.425, year: 2016

  17. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    International Nuclear Information System (INIS)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion

  18. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa [Istanbul University, Istanbul (Turkmenistan)

    2015-12-15

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.

  19. Prenatal diagnostic procedures used in pregnancies with congenital malformations in 14 regions of Europe

    NARCIS (Netherlands)

    Garne, E; Loane, M; de Vigan, C; Scarano, G; de Walle, H; Gillerot, Y; Stoll, C; Addor, MC; Stone, D; Gener, B; Feijoo, M; Mosquera-Tenreiro, C; Gatt, M; Queisser-Luft, A; Baena, N; Dolk, H

    2004-01-01

    Objective To investigate outcomes of ultrasound investigations (US) and invasive diagnostic procedures in cases of congenital malformations (CM), and to compare the use of invasive prenatal test techniques (amniocentesis (AC) versus chorionic villus sampling (CVS)) among European populations. Design

  20. Evaluation of nuclear power plant operating procedures classifications and interfaces: Problems and techniques for improvement

    International Nuclear Information System (INIS)

    Barnes, V.E.; Radford, L.R.

    1987-02-01

    This report presents activities and findings of a project designed to evaluate current practices and problems related to procedure classification schemes and procedure interfaces in commercial nuclear power plants. The phrase ''procedure classification scheme'' refers to how plant operating procedures are categorized and indexed (e.g., normal, abnormal, emergency operating procedures). The term ''procedure interface'' refers to how reactor operators are instructed to transition within and between procedures. The project consisted of four key tasks, including (1) a survey of literature regarding problems associated with procedure classifications and interfaces, as well as techniques for overcoming them; (2) interviews with experts in the nuclear industry to discuss the appropriate scope of different classes of operating procedures and techniques for managing interfaces between them; (3) a reanalysis of data gathered about nuclear power plant normal operating and off-normal operating procedures in a related project, ''Program Plan for Assessing and Upgrading Operating Procedures for Nuclear Power Plants''; and (4) solicitation of the comments and expert opinions of a peer review group on the draft project report and on proposed techniques for resolving classification and interface issues. In addition to describing these activities and their results, recommendations for NRC and utility actions to address procedure classification and interface problems are offered

  1. Survey of prenatal counselling practices regarding aneuploidy risk modification, invasive diagnostic procedure risks, and procedure eligibility criteria in Canadian centres.

    Science.gov (United States)

    Hull, Danna; Davies, Gregory; Armour, Christine M

    2012-07-01

    To explore prenatal practices related to aneuploidy screening, risk modification, and invasive diagnostic procedures across Canadian centres. We conducted a survey of members of the Canadian Association of Genetic Counsellors, the Canadian College of Medical Genetics, and the Canadian Society of Maternal Fetal Medicine, who provide direct counselling or management of prenatal patients in Canada. Eighty-two of 157 respondents indicated that their centre's definition of advanced maternal age was ≥ 35 years, with 33/157 respondents reporting an advanced maternal age definition of ≥ 40 years. The majority of respondents reported that prenatal serum screening for aneuploidy is provincially funded in their province or territory (121/147). The majority of respondents who reported that prenatal screening is not provincially funded (17/147) were from Quebec (14/17). Thirty-nine of 123 respondents reported that their centre defines increased nuchal translucency as ≥ 3.0 mm, whereas 49/123 reported a definition of ≥ 3.5 mm. Sixty-four of 150 respondents reported that the aneuploidy risk provided by serum screening is modified by a soft marker likelihood ratio, whereas 46/150 respondents reported that both age-related and serum screening risks are modified. Fifty-nine of 124 respondents reported that their centre will modify aneuploidy risk after a normal ultrasound; the most commonly cited negative likelihood ratio was 0.5. The most commonly reported procedure-related risk for chorionic villus sampling was 1/100 (123/147) and for amniocentesis was 1/200 (73/142). This study demonstrates inconsistencies in prenatal practices and access to screening programs across Canada. The information gained from this study will inform policy advisors developing prenatal practice guidelines at both the provincial and national levels.

  2. Evaluation of techniques for inspection and diagnostics of HWR pressure tubes

    International Nuclear Information System (INIS)

    Choi, Jong-Ho

    2008-01-01

    Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes for Heavy Water Reactors (HWRs), are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. The objective of the CRP was to inter-compare inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of the CRP, participants investigated the capability of different techniques to detect and characterize flaws. During the second phase, participants collaborated to determine the hydrogen concentration and to detect and characterize hydride blisters in zirconium alloy pressure tubes. Eight organizations from six countries, which operate HWRs, have participated in this CRP, Most of the techniques examined are well established and many of them are regularly used during in-service inspection of pressure tubes. The inter-comparison of these techniques provides a platform for identifying a particular technique (or a set of techniques), which is more accurate and reliable as compared to others for a specified task. The CRP also witnessed some new methodologies, which can be implemented on in-service inspection tools. These new techniques could complement the existing ones to overcome their limitations, thereby improving the reliability and accuracy of in-service inspection. This CRP also identified future areas of research and development. (author)

  3. Pulmonary infiltrates in non-HIV immunocompromised patients: a diagnostic approach using non-invasive and bronchoscopic procedures

    Science.gov (United States)

    Rano, A; Agusti, C; Jimenez, P; Angrill, J; Benito, N; Danes, C; Gonzalez, J; Rovira, M; Pumarola, T; Moreno, A; Torres, A

    2001-01-01

    %); and TBAS 35/55 (65%). Bronchoscopic techniques led to the diagnosis of pulmonary infiltrates in 59% of the cases in which they were used: FBAS 16/28 (57%), BAL 68/135 (51%), and PSB 30/125 (24%). The results obtained with the different techniques led to a change in antibiotic treatment in 93 cases (46%). Although changes in treatment did not have an impact on the overall mortality, patients with pulmonary infiltrates of an infectious aetiology in whom the change was made during the first 7 days had a better outcome (29% mortality) than those in whom treatment was changed later (71% mortality; p=0.001).
CONCLUSIONS—Non-invasive and bronchoscopic procedures are useful techniques for the diagnosis of pulmonary infiltrates in immunocompromised patients. Bronchial aspirates (FBAS and TBAS) and BAL have the highest diagnostic yield and impact on therapeutic decisions.

 PMID:11312407

  4. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-01-01

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added

  5. Radiation injury of the skin following diagnostic and interventional fluoroscopic procedures

    International Nuclear Information System (INIS)

    Koenig, T.R.; Wagner, L.K.; Mettler, F.A.

    2001-01-01

    Many radiation injuries to the skin, resulting from diagnostic and interventional fluoroscopic procedures, have been reported in recent years. In some cases skin damage was severe and debilitating. We analyzed 72 reports of skin injuries for progression and location of injury, type and number of procedures, and contributing patient and operator factors. Most cases (46) were related to coronary angiography and percutaneous transluminal coronary angioplasty (PTCA). A smaller number was documented after cardiac radiofrequency catheter ablation (12), transjugular intrahepatic portosystemic shunt (TIPS) placement (7), neuroradiological interventions (3) and other procedures (4). Important factors leading to skin injuries were long exposure times over the same skin area, use of high dose rates, irradiation through thick tissue masses, hypersensitivity to radiation, and positioning of arms or breasts into the radiation entrance beam. Physicians were frequently unaware of the high radiation doses involved and did not recognize the injuries as radiation induced. Based on these findings, recommendations to reduce dose and improve patient care are provided. (author)

  6. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  7. Perceived risk of prenatal diagnostic procedure-related miscarriage and Down syndrome among pregnant women.

    Science.gov (United States)

    Caughey, Aaron B; Washington, A Eugene; Kuppermann, Miriam

    2008-03-01

    The objective of the study was to identify correlates of perceived risk of carrying a Down syndrome-affected fetus or experiencing a procedure-related miscarriage among a diverse group of pregnant women. We conducted a cross-sectional survey of 1081 English-, Spanish-, or Chinese-speaking women receiving prenatal care in the San Francisco Bay area. Perceived risk of procedure-related miscarriage or carrying a Down syndrome-affected fetus was assessed using a linear rating scale from 0 (no risk) to 1 (high risk). Bivariate and multivariable analyses were used to explore associations between maternal characteristics including age, race/ethnicity, and socioeconomic status and perceived risks of carrying a Down syndrome-affected fetus or experiencing a procedure-related miscarriage. Women aged 35 years old or older had a higher perceived risk of Down syndrome than younger women (0.28 vs 0.22 on a scale from 0 to 1, P self-perceived health status (+0.08, P = .045). Latinas (+0.11, P = .008), women with an annual income less than $35,000 (+0.09, P = .003), and those who had difficulty conceiving (+0.09, P = .026) had higher perceived procedure-related miscarriage risk. Among women aged 35 years or older, perceived risk of carrying a Down syndrome-affected fetus was associated with the inclination to undergo prenatal diagnosis. Women's perceived risks of carrying a Down syndrome-affected fetus or having a procedure-related miscarriage are associated with numerous characteristics that have not been shown to be associated with the actual risks of these events. These perceived risks are associated with prenatal diagnostic test inclination. Understanding patients' risk perceptions and effectively communicating risk is critical to helping patients make informed decisions regarding use of invasive prenatal testing.

  8. The effectiveness of drama therapy on preparation for diagnostic and therapeutic procedures in children suffering from cancer

    Directory of Open Access Journals (Sweden)

    Ľubica Ilievová

    2015-10-01

    Full Text Available Introduction: The integral part of the treatment of pediatric oncological patients is a range of diagnostic and therapeutic procedures. These procedures are often associated with the fear and anxiety of the suffering child. We investigated whether a psychological preparation through drama therapy and the therapeutic puppet may reduce the anxiety related to diagnostic and therapeutic procedures in the preschool or early school children suffering from cancer.Methods: Twenty consecutive pediatric patients of preschool and early school age, with the diagnosis of lymphoblastic leukemia, were included in the study. The patients were alternatingly assigned to experimental or control group, and subjected or not subjected to drama therapy, respectively. We measured the changes in heart rate, blood pressure and respiratory rate as indicators of anxiety and fear, before and after the diagnostic or therapeutic procedures.Results: Heart rate, blood pressure, and respiratory rate in pediatric oncological patients before and after the diagnostic or therapeutic procedure were significantly lower in the experimental group of patients.Conclusion: Our results show that psychological preparation using drama therapy and therapeutic puppet reduced the fear and anxiety related to diagnostic or therapeutic procedures in pediatric oncological patients.Key words: drama therapy; therapeutic puppet; children; oncology; psychology 

  9. Actinic Keratosis and Non-Invasive Diagnostic Techniques: An Update

    Science.gov (United States)

    Casari, Alice; Chester, Johanna; Pellacani, Giovanni

    2018-01-01

    Actinic keratosis represents the earliest manifestation of non-melanoma skin cancer. Because of their risk of progression to invasive squamous cell carcinoma, an earlier diagnosis and treatment are mandatory. Their diagnosis sometimes could represent a challenge even for expert dermatologists. Dermoscopy, confocal laser microscopy and optical coherence tomography could help clinicians in diagnosis. PMID:29316678

  10. Reference Guide for Building Diagnostics Equipment and Techniques

    Science.gov (United States)

    1989-07-01

    imaging systems, can be cali- 6155 El Camino Real, Carlsbad, Calif. 92008, (619) brated in temperature and radiosity . 931-3617; FUR Systems Inc., 16505...of microproces- or ctigital) in degrees Celsius or Fahrenheit or a sor technology, state-of-the-art optical and sight- radiosity display in Btu/ft2

  11. Lithium-ion battery diagnostic and prognostic techniques

    Science.gov (United States)

    Singh, Harmohan N.

    2009-11-03

    Embodiments provide a method and a system for determining cell imbalance condition of a multi-cell battery including a plurality of cell strings. To determine a cell imbalance condition, a charge current is applied to the battery and is monitored during charging. The charging time for each cell string is determined based on the monitor of the charge current. A charge time difference of any two cell strings in the battery is used to determine the cell imbalance condition by comparing with a predetermined acceptable charge time difference for the cell strings.

  12. Foetal Radiation Dose and Risk from Diagnostic Radiology Procedures: A Multinational Study

    International Nuclear Information System (INIS)

    Osei, Ernest K.; Darko, Johnson

    2012-01-01

    In diagnostic radiology examinations there is a benefit that the patient derives from the resulting diagnosis. Given that so many examinations are performed each year, it is inevitable that there will be occasions when an examination(s) may be inadvertently performed on pregnant patients or occasionally it may become clinically necessary to perform an examination(s) on a pregnant patient. In all these circumstances it is necessary to request an estimation of the foetal dose and risk. We initiated a study to investigate fetal doses from different countries. Exposure techniques on 367 foetuses from 414 examinations were collected and investigated. The FetDoseV4 program was used for all dose and risk estimations. The radiation doses received by the 367 foetuses ranges: <0.001–21.9 mGy depending on examination and technique. The associated probability of induced hereditary effect ranges: <1 in 200000000 (5 × 10 −9 ) to 1 in 10000 (1 × 10 −4 ) and the risk of childhood cancer ranges <1 in 12500000 (8 × 10 −8 ) to 1 in 500 (2 × 10 −3 ). The data indicates that foetal doses from properly conducted diagnostic radiology examinations will not result in any deterministic effect and a negligible risk of causing radiation induced hereditary effect in the descendants of the unborn child

  13. Epidemiology of intestinal parasitosis in Italy between 2005 and 2008: diagnostic techniques and methodologies

    Directory of Open Access Journals (Sweden)

    Daniele Crotti

    2013-04-01

    Full Text Available Aim of the study was to keep a real and actual photo relating to 2005-2008 regarding to diagnostic techniques and methodologies for intestinal parasites; so it would be possible to know specific epidemiology and suggest more rational and efficacious guide-lines. All members of AMCLI were involved in the proposal of a retrospective study regarding bowel parasites, helminths and protozoa.To engaged laboratories we asked how O&P was performed, if a specifical research for E. vermicularis and S. stercoralis was performed, if for the identification of D. fragilis, Entamoeba histolytica/dispar and Cryptosporidum spp were performed recommended specific permanent stains. 23 laboratories gave assent; but for an inferior number was possible to use the data for analysis and evaluation. Relating O&P only some laboratories performed permanent stains: Giemsa for D. fragilis, antigen and/or Trichrome stain for E. histolytica/dispar, antigen and/or acid fast stain for Cryptosporidium spp.Not all laboratories research specifically S. stercoralis. So the epidemiology is differentiated and related more to adequate or not adequate techniques than cohorts of examined populations. The overall positivity for parasites ranged from 0% to18.7%,for protozoa (pathogens or not were from 0% to 14.7%; for nematodes from 0% to 3.7%; for cestodes from 0% to 1.0%; for trematodes from 0% to 1.0%.Among helminths, E. vermicularis, followed by S. stercoralis, also in O&P, is the most frequent.The specific research of S. stercoralis gave a positivity from 0% to 33.3%; the cellophane tape test was positive for E. vermicularis from 0% fo 21.9% of cases.Among pathogen protozoa, D. fragilis, when permanent stain were applied, prevailed from 0% to 16.6%; G. duodenalis from 0.8% to 4.3%; E. histolytica/dispar, using a permanent stain or research of antigen, was identified from 0% to 20.6%. Coccidia were very rare, with Cryptosporidium spp observed from 0% to 5.2%. These are our conclusions

  14. Student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures

    International Nuclear Information System (INIS)

    Zhou, G. Z.; Wong, D. D.; Nguyen, L. K.; Mendelson, R. M.

    2010-01-01

    Full text: This study aims to evaluate medical student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures and to suggest how education could be improved. Fourth to sixth year medical students enrolled at a Western Australian university and interns from three teaching hospitals in Perth were recruited. Participants were asked to complete a questionnaire consisting of 26 questions on their background, knowledge of ionising radiation doses and learning preferences for future teaching on this subject. A total of 331 completed questionnaires were received (95.9%). Of the 17 questions assessing knowledge of ionising radiation, a mean score of 6.0 was obtained by respondents (95% CI 5.8-6.2). Up to 54.8% of respondents underestimated the radiation dose from commonly requested radiological procedures. Respondents (11.3 and 25.5%) incorrectly believed that ultrasound and MRI emit ionising radiation, respectively. Of the four subgroups of respondents, the intern doctor subgroup performed significantly better (mean score 6.9, P< 0.0001, 95% CI 6.5-7.3) than each of the three medical student subgroups. When asked for the preferred method of teaching for future radiation awareness, a combination of lectures, tutorials and workshops was preferred. This study has clearly shown that awareness of ionising radiation from diagnostic imaging is lacking among senior medical students and interns. The results highlight the need for improved education to minimise unnecessary exposure of patients and the community to radiation. Further studies are required to determine the most effective form of education.

  15. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    Science.gov (United States)

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.

  16. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  17. Patient and staff doses in fluoroscopically guided invasive diagnostic and interventional urology procedures

    International Nuclear Information System (INIS)

    Ivanova, D.; Hristova-Popova, J.; Avramova-Cholakova, S.; Deyanova, Ts.; Dobrikov, R.

    2015-01-01

    Full text: The aim of this study is to evaluate patient and staff doses in fluoroscopically guided invasive diagnostic and interventional urology procedures. All the data were collected in the Emergency Hospital 'N. I. Pirogov'. While recording data for the patients, a real time dosimetry measurement of the medical staff was made. Air kerma-area product (KAP) was recorded for intravenous pyelogram (IVP), percutaneous nephrostomy (PN) and ureteral 'double-J' stenting. Patient data sex, age and weight were also taken. Staff doses were estimated with the system RaySafe i2. It contains four dosimeters, with a wireless connection to a real time display. The dosimeters were worn on the unprotected upper part of the body and measured the personal dose equivalent Hp(10). The mean KAP values for the procedures are: 3.21 Gy.cm 2 for IVP, 10.37 Gy.cm 2 for PN and 4.15 Gy.cm 2 for 'double-J' respectively. The highest staff dose for PN and 'double-J' is received by the urologist (160 μSv and 47.3 μSv, respectively), while for the IVP the radiographer has the highest exposure (20 μSv). Each member of the medical staff was on a different position in respect to the X-ray tube and the patient, which is the main reason for the differences in the staff doses. The variations in the mean patient and staff doses are mostly due to the interventions themselves, their complexity and the individual treatment of every patient. RaySafe i2 is very useful as guideline for making a choice of a better position and in the decreasing of radiation exposure to the staff

  18. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  19. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  20. The first successful laparoscopic Whipple procedure at Hat Yai Hospital: surgical technique and a case report.

    Science.gov (United States)

    Khaimook, Araya; Borkird, Jumpot; Alapach, Sakda

    2010-09-01

    Whipple procedure is the most complex abdominal surgical procedure to treat periampullary carcinoma. With the benefit of minimally invasive approach, many institutes attempt to do Whipple procedure laparoscopically. However, only 146 cases of laparoscopic Whipple procedure have yet been reported in the literature worldwide between 1994 and 2008. The authors reported the first laparoscopic Whipple procedure at Hat Yai Hospital in December 2009. The patient was a 40-year-old, Thai-Muslim female, with the diagnosis of ampullary carcinoma. The operating time was 685 minutes. The patient was discharged on postoperative day 14 without serious complication. The surgical technique and postoperative progress of the patient were described.

  1. Evaluation of diagnostic procedures in nuclear medicine services of Pernambuco and Alagoas states - Brazil

    International Nuclear Information System (INIS)

    Silva, Ricardo Braz F. da; Hazin, Clovis A.

    2011-01-01

    The medical use of ionizing radiation contributes significantly to population exposure to radiation. This study aimed to evaluate the diagnostic procedures carried out in nuclear medicine (SMN) in Pernambuco and Alagoas in order to gather data to subsidize the proposal of reference levels for nuclear medicine in Brazil. Data were collected of the SMN in Pernambuco and Alagoas in the period of 2005 to 2009, according by UNSCEAR. The study used data from IBGE. The results showed that the total number of examinations in the period 2005 to 2009 was 34.828 in Pernambuco and 27.700 in Alagoas, corresponding to 6.966 and 5.540 average annual examinations in Pernambuco and Alagoas, respectively. The total number of examinations performed in both states in 2009 was twice the number carried out in 2005. Scintigraphy is the cardiovascular examination most performed in both states, followed by bone scintigraphy. Tc-99m is the radionuclide used most often, followed by I-131. The number of tests using Tc-99m in 2009 doubled when compared with the examinations performed in 2005. The results indicate that there has been a significant increase in the number of examinations in MN, and that females outnumber males, as far as the use of this diagnostic resource is concerned. The study of the activities of the radionuclides administered to patients in the states of Pernambuco and Alagoas showed that they are high when compared to the values recommended by the IAEA in its Safety Report Series Document No. 40. (author)

  2. Antegrade jj stenting after percutaneous renal procedures: The ‘pull and push’ technique

    Science.gov (United States)

    Ratkal, Jaideep M.; Sharma, Elias

    2014-01-01

    A JJ stent is inserted antegradely after percutaneous renal procedures like percutaneous nephrolithotomy (PCNL) for renal calculus disease, and for endopyelotomy for pelvi-ureteric junction obstruction. We describe a technique for antegrade stent insertion after PCNL. PMID:26413327

  3. Antegrade jj stenting after percutaneous renal procedures: The 'pull and push' technique.

    Science.gov (United States)

    Ratkal, Jaideep M; Sharma, Elias

    2015-06-01

    A JJ stent is inserted antegradely after percutaneous renal procedures like percutaneous nephrolithotomy (PCNL) for renal calculus disease, and for endopyelotomy for pelvi-ureteric junction obstruction. We describe a technique for antegrade stent insertion after PCNL.

  4. Tactics, Techniques, and Procedures (TTP) for Migrant Camp Operations

    Science.gov (United States)

    1995-04-15

    female medical personnel and be questioned about pregnancy . Medical examinations should be properly supervised, be conducted only by qualified personnel...factors, and the special risks associated with pregnancy , children (especially neonatal), and the malnourished. 7. Drug List Exclusions. Figures 1...chlorhexidine solution 100 benzoic acid + salicylic acid cream 25 calamine lotion 25 gentian violet Anaemia 10% = 500 500 ferrous salt

  5. Diagnostic imaging procedure volume in the United States

    International Nuclear Information System (INIS)

    Johnson, J.L.; Abernathy, D.L.

    1983-01-01

    Comprehensive data on 1979 and 1980 diagnostic imaging procedure volume were collected from a stratified random sample of U.S. short-term general-care hospitals and private practices of radiologists, cardiologists, obstetricians/gynecologists, orthopedic surgeons, and neurologists/neurosurgeons. Approximately 181 million imaging procedures (within the study scope) were performed in 1980. Despite the rapidly increasing use of newer imaging methods, plain film radiography (140.3 million procedures) and contrast studies (22.9 million procedures) continue to comprise the vast majority of diagnostic imaging volume. Ultrasound, computed tomography, nuclear medicine, and special procedures make up less than 10% of total diagnostic imaging procedures. Comparison of the data from this study with data from an earlier study indicates that imaging procedure volume in hospitals expanded at an annual growth rate of almost 8% from 1973 to 1980

  6. Hospital discharge diagnostic and procedure codes for upper gastro-intestinal cancer: how accurate are they?

    Directory of Open Access Journals (Sweden)

    Stavrou Efty

    2012-09-01

    Full Text Available Abstract Background Population-level health administrative datasets such as hospital discharge data are used increasingly to evaluate health services and outcomes of care. However information about the accuracy of Australian discharge data in identifying cancer, associated procedures and comorbidity is limited. The Admitted Patients Data Collection (APDC is a census of inpatient hospital discharges in the state of New South Wales (NSW. Our aim was to assess the accuracy of the APDC in identifying upper gastro-intestinal (upper GI cancer cases, procedures for associated curative resection and comorbidities at the time of admission compared to data abstracted from medical records (the ‘gold standard’. Methods We reviewed the medical records of 240 patients with an incident upper GI cancer diagnosis derived from a clinical database in one NSW area health service from July 2006 to June 2007. Extracted case record data was matched to APDC discharge data to determine sensitivity, positive predictive value (PPV and agreement between the two data sources (κ-coefficient. Results The accuracy of the APDC diagnostic codes in identifying site-specific incident cancer ranged from 80-95% sensitivity. This was comparable to the accuracy of APDC procedure codes in identifying curative resection for upper GI cancer. PPV ranged from 42-80% for cancer diagnosis and 56-93% for curative surgery. Agreement between the data sources was >0.72 for most cancer diagnoses and curative resections. However, APDC discharge data was less accurate in reporting common comorbidities - for each condition, sensitivity ranged from 9-70%, whilst agreement ranged from κ = 0.64 for diabetes down to κ  Conclusions Identifying incident cases of upper GI cancer and curative resection from hospital administrative data is satisfactory but under-ascertained. Linkage of multiple population-health datasets is advisable to maximise case ascertainment and minimise false

  7. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  8. Effectiveness of relaxation techniques before diagnostic screening of cancer patients

    Directory of Open Access Journals (Sweden)

    Montserrat Aiger

    2016-07-01

    Full Text Available Psychophysiological arousal was observed in cancer patients during the application of relaxation techniques prior to a diagnostic scan (PET-CT. The aim of the study is twofold: firstly, it is sought to establish whether such techniques can minimize patient arousal before diagnostic screening begins, and secondly to measure which of them are most effective. The dependent variable is electrodermal activity, recording the attentional level and emotional response, and the independent variable comprises the relaxation techniques used, namely Jacobson, breathing and visualization. The 39 patients were split into experimental groups to whom the relaxation techniques (Jacobson, breathing exercises, and visualization were applied before they went for the PET-CT. An activity-module procedure was applied to track electrodermal activity during the relaxation sessions, consisting of instructions, timeout; wait, task; relaxation and end of the recording session. The control group received no relaxation techniques before the PET-CT. Session-end results show that patients who perform relaxation techniques achieve greater attentional focus using Jacobson's technique (M = .212 and enhanced emotional containment using visualization (M = .206. It is concluded that relaxation techniques minimize the state of activation during the waiting period before a diagnostic scan.

  9. Consensus guidelines for the use of bowel preparation prior to colonic diagnostic procedures: colonoscopy and small bowel video capsule endoscopy

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth; Pellisé, Maria; Heresbach, Denis; Fischbach, Wolfgang; Dixon, Tricia; Belsey, Jonathan; Parente, Fabrizio; Rio-Tinto, Ricardo; Brown, Alistair; Toth, Ervin; Crosta, Cristiano; Layer, Peter; Epstein, Owen; Boustiere, Christian

    2013-01-01

    Adequate bowel preparation prior to colonic diagnostic procedures is essential to ensure adequate visualisation. This consensus aims to provide guidance as to the appropriate use of bowel preparation for a range of defined clinical circumstances. A consensus group from across Europe was convened and

  10. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  11. Novel Nonlinear Laser Diagnostic Techniques

    Science.gov (United States)

    1993-07-01

    a thermometric probe of reactive flows. Since the two-photon pump laser couples a Doppler broadened ground state velocity distribution to the excited...rism, and passed unfocused into an aluminum cell con- in frequency space. Regions for line fitting are found by taining 99% pure NO. The gas mixture...of ASE as a More recently, ASE has prompted interest as an thermometric probe of combustion environments optical diagnostic of combustion environments

  12. Alternative diagnostic technique for carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Hayakawa, Katsuhiko; Nakane, Takashi; Kobayashi, Shigeru; Shibata, Kunio

    2002-01-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  13. Alternative diagnostic technique for carpal tunnel syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Katsuhiko; Nakane, Takashi [Aiko Orthopaedic Hospital, Nagoya (Japan); Kobayashi, Shigeru; Shibata, Kunio [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine

    2002-10-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  14. Activities of radiopharmaceuticals administered for diagnostic and therapeutic procedures in nuclear medicine in Argentina: results of a national survey

    International Nuclear Information System (INIS)

    Bomben, Ana M.; Chiliutti, Claudia A.

    2004-01-01

    Nuclear medicine in Argentine is carried out at 292 centres, distributed all over the country, mainly concentrated in the capital cities of the provinces. With the purpose of knowing the activity levels of radiopharmaceuticals that were administered to patients for diagnostic and therapeutic procedures in nuclear medicine, a national survey was conducted, during 2001 and 2002. This survey was answered voluntarily by 107 centres. Sixty-four percent of the participants centres are equipped with SPECT system while the other centres have a gamma camera or scintiscanner. There were 37 nuclear medicine procedures, chosen among those most frequently performed, were included in the survey. In those diagnostic procedures were included tests for: bone, brain, thyroid, kidney, liver, lung and cardiovascular system; and also activities administered for some therapeutic procedures. The nuclear medicine physicians reported the different radiopharmaceutical activities administered to typical adult patients. In this paper are presented the average radiopharmaceutical activity administered for each of the diagnostic and therapeutic procedures included in the survey and the range and distribution of values. In order to place these data in a frame of reference, these average values were compared to the guidance levels for diagnostic procedures in nuclear medicine mentioned at the Safety Series no. 115. From this comparison it was noticed that the activities administered in the 40% of the diagnostic procedures included in the survey were between ±30% of the reference values. For those nuclear medicine procedures that could not be compared with the above mentioned guidance levels, the comparison was made with values published by UNSCEAR or standards recommended by international bodies. As a result of this study, it is important to point out the need to continue the gathering of data in a wider scale survey to increase the knowledge about national trends. It is also essential to widely

  15. Unproven diagnostic procedures in IgE-mediated allergic diseases.

    Science.gov (United States)

    Niggemann, B; Grüber, C

    2004-08-01

    A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.

  16. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  17. Evidence-based medical research on diagnostic criteria and screening technique of vascular mild cognitive impairment

    Directory of Open Access Journals (Sweden)

    Xia-wei LIU

    2015-07-01

    Full Text Available Background Vascular mild cognitive impairment (VaMCI is the prodromal syndrome of vascular dementia (VaD and key target for drug treatment. There is controversy over the diagnostic criteria and screening tools of VaMCI, which affects its clinical diagnosis. This paper aims to explore the clinical features, diagnostic criteria and screening technique of VaMCI.  Methods Taking "vascular mild cognitive impairment OR vascular cognitive impairment no dementia" as retrieval terms, search in PubMed database from January 1997 to March 2015 and screen relevant literatures concerning VaMCI. According to Guidance for the Preparation of Neurological Management Guidelines revised by European Federation of Neurological Societies (EFNS in 2004, evidence grading was performed on literatures. Results A total of 32 literatures in English were selected according to inclusion and exclusion criteria, including 3 guidelines and consensus and 29 clinical studies. Seven literatures (2 on Level Ⅰ, 5 on Level Ⅱ studied on neuropsychological features in VaMCI patients and found reduced processing speed and executive function impairment were main features. Two literatures reported the diagnostic criteria of VaMCI, including VaMCI criteria published by American Heart Association (AHA/American Stroke Association (ASA in 2011 and "Diagnostic Criteria for Vascular Cognitive Disorders" published by International Society for Vascular Behavioral and Cognitive Disorders (VASCOG in 2014. Fifteen literatures (4 on LevelⅠ, 11 on Level Ⅱ described the diagnostic criteria of VaMCI used in clinical research, from which 6 operational diagnostic items were extracted. Fourteen literatures (4 on Level Ⅰ, 10 on Level Ⅱ described neuropsychological assessment tools for VaMCI screening, and found the 5-minute protocol recommended by National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN was being good consistency with other neuropsychological

  18. Advanced crew procedures development techniques: Procedures and performance program training plan

    Science.gov (United States)

    Arbet, J. D.; Benbow, R. L.

    1975-01-01

    A plan developed to support the training of PPP users in the operations associated with PPP usage is described. This document contains an overview of the contents of each training session and a detailed outline to be used as the guideline for each session.

  19. Calculation and experimental technique of determination of rolling procedure for cold-rolling tube mills

    International Nuclear Information System (INIS)

    Igoshin, V.F.; Aleshin, V.A.; Khoroshikh, Yu.G.; Bogatov, A.A.; Mizhiritskij, O.I.

    1983-01-01

    Calculation and experimental technique of determination of tube cold rolling procedure has been developed. Rolling procedure based on the usage of regression equation epsilon=1.24 psi, where psi is the relative reduction of area, delta-permissible reduction during rolling, has been tested on 08Kh18N10T steel. The effect of tube geometry, tool calibration parameters, lubrication conditions etc. on metal deformability in taking into account experimentally. The use of the technique proposed has allowed to shorten the time of mastering of the production of tubes from different steels

  20. Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniques

    International Nuclear Information System (INIS)

    Ferreira, Sergio L.C.; Andrade, Jailson B. de; Korn, Maria das Gracas A.; Pereira, Madson de G.; Lemos, Valfredo A.; Santos, Walter N.L. dos; Rodrigues, Frederico de Medeiros; Souza, Anderson S.; Ferreira, Hadla S.; Silva, Erik G.P. da

    2007-01-01

    Spectrometric techniques for the analysis of trace cadmium have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, such as electrochemical deposition, precipitation, coprecipitation, solid phase extraction, liquid-liquid extraction (LLE) and cloud point extraction (CPE), and consider the features of the their application with several spectrometric techniques

  1. Picosecond high power laser systems and picosecond diagnostic technique in laser produced plasma

    International Nuclear Information System (INIS)

    Kuroda, Hiroto; Masuko, H.; Maekawa, Shigeru; Suzuki, Yoshiji; Sugiyama, Masaru.

    1979-01-01

    Highly repetitive, high power YAG and Glass laser systems have been developed and been successfully used for the studies of laser-plasma interactions. Various picosecond diagnostic techniques have been developed for such purposes in the regions from optical to X-ray frequency. Recently highly sensitive X-ray (1 - 10 KeV) streak camera for highly repetitive operations have been developed. Preliminary experiment shows the achievement of 28ps temporal resolution (100μm slit) and good sensitivity with detectable minimum number of 10E3-1KeV photons/shot/slit area. (author)

  2. An overview of anesthetic procedures, tools, and techniques in ambulatory care

    Directory of Open Access Journals (Sweden)

    Messieha Z

    2015-01-01

    Full Text Available Zakaria Messieha Department of Anesthesiology, University of Illinois at Chicago, Chicago, IL, USA Abstract: Ambulatory surgical and anesthesia care (ASAC, also known as Same Day Surgery or Day Care in some countries, is the fastest growing segment of ambulatory surgical and anesthesia care. Over 50 million ambulatory surgical procedures are conducted annually comprising over 60% of all anesthesia care with an impressive track record of safety and efficiency. Advances in ambulatory anesthesia care have been due to newer generation of inhalation and intravenous anesthetics as well as airway management technology and techniques. Successful ambulatory anesthesia care relies on patient selection, adequate facilities, highly trained personnel and quality improvement policies and procedures. Favoring one anesthetic technique over the other should be patient and procedure-specific. Effective management of post-operative pain as well as nausea and vomiting are the final pieces in assuring success in ambulatory anesthesia care. Keywords: ambulatory anesthesia, out-patient anesthesia, Day-Care anesthesia

  3. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  4. Application of RNB for high sensitive wear diagnostics in medicine technique and industry

    International Nuclear Information System (INIS)

    Fehsenfeld, P.; Eifrig, C.; Kubat, R.

    2002-01-01

    The RTM--Radionuclide Technique in Mechanical engineering--is now extended to the solution of world wide problems in medicine technique (prosthetics), and in development of modern materials (synthetic materials, ceramics, hard coatings, etc.) and their industrial application. RNB--Radioactive Nuclear Beams of 7 Be or 22 Na--may enable the required extreme thin radioactive surface labeling (several micrometers) of synthetic materials for wear measurements without producing radiation damages of influence to the wear properties of the material. The function principle and special properties of the RTM on-line wear diagnostics and its components, the measurement methods, the radioactive surface labeling, and the measurement instruments are explained. The quality features of a 7 Be and 22 Na-beam for RTM application are specified

  5. Hallux Valgus Deformity and Treatment: A Three-Dimensional Approach: Modified Technique for Lapidus Procedure.

    Science.gov (United States)

    Santrock, Robert D; Smith, Bret

    2018-06-01

    In a hallux valgus deformity, the problem is deviation of the hallux at the metatarsophalangeal joint and of the first metatarsal at the tarsometatarsal joint. Although anterior-posterior radiograph findings have been prioritized, deviation in the other planes can substantially change visible cues. The modified technique for Lapidus procedure procedure, uses all 3 planes to evaluate and correct the deformity, making radiographic measurements less useful. Using a triplane framework and focusing on the apex of the deformity, all bunions become the same modified technique for Lapidus procedure can be performed regardless of the degree of deformity, always includes triplane correction, and deformity size becomes irrelevant. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Guogen Shan

    2015-01-01

    Full Text Available Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003. However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  7. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  8. Diagnostic procedures of the solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Aoe, Keisuke; Hiraki, Akio; Kohara, Hiroyuki

    2003-01-01

    The spread of computed tomography (CT) brought the frequent further examinations of the solitary pulmonary nodules (SPN). To aim the evaluation of initial data on examinations of SPN for differential diagnosis, we studied retrospective cases. Thirty-one cases of SPN less than 20 mm in diameter were compared in clinical findings and CT image findings and were examined the diagnostic procedures in recent three years in National Sanyo Hospital. The 31 patients consisted of 14 males and 17 females ranging 44 to 79 years old, median 65 years old. The causes of SPN were lung cancer (11 patients), cryptococcosis (4 patients), tuberculoma (3 patients), non-tuberculous mycobacteria (2 patients), pneumoconiosis (2 patients), pneumonia scar (one patient), hamartoma (one patient), and unknown (7 patients). There were no significant differences in laboratory findings between lung cancer and the others. CT findings showed significant differences in four categories. All patients underwent fiberoptic bronchoscopy (FB) examinations and 12 patients were determined the diagnosis initial FB. Five patients were established their diagnosis using videoassociated thoracoscopic surgeries. (author)

  9. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  10. Therapeutic and diagnostic procedures in preinvasive disease of the cervix and cervical cancer in pregnant women

    International Nuclear Information System (INIS)

    Wolna, M.; Pisarski, T.; Kedzia, H.

    1993-01-01

    154 pregnant women with displasis and cervical carcinoma of the uterus treated in the Institute in years 1953-1990 underwent investigation. Authors noticed that only 50 pathologies were diagnosed in 1st trimester of pregnancy and 85% constituted precancerous and early forms of carcinoma of the uterine cervix. Authors presented the model of management and care of pregnancy, labour and puerperium in these patients. Due to this procedure we obtained 90% comparability of preliminary and final diagnosis. (author)

  11. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  12. Technique of infrared synchrotron acceleration diagnostics

    International Nuclear Information System (INIS)

    Mal'tsev, A.A.; Mal'tsev, M.A.

    1997-01-01

    Techniques of measuring of current and geometric parameters and evaluating of energy parameters of the ring bunch of relativistic low-energy electrons have been presented. They have been based on using the synchrotron radiation effect in its infrared spectral part. Fast infrared detectors have provided radiation detection in the spectral range Δλ ≅ 0.3-45 μm. The descriptions of some data monitoring and measuring systems developed in JINR for the realization of techniques of the infrared synchrotron acceleration diagnostics have been given. Infrared optics elements specially developed have been used in these systems

  13. Anaesthesiological aspects of thorax-diagnostic procedures in intensive-care units

    International Nuclear Information System (INIS)

    Schulte am Esch, J.

    1989-01-01

    Diagnostic procedures of the thorax in intensive-care units are conventional X-ray chest images, chest images by digital luminescence radiography, sonography and transoesophageal Doppler echocardiography. In addition to these bedside methods the stationary usable techniques, such as computed tomography, digital subtraction angiography and the seldom in intensive care patients used computed nuclear spin resonance tomography (NMR) are applicable. The selection of the above mentioned techniques depends on the availability and the quality of the methods as well as the qualifications of the involved staff. The diagnostic procedures of the chest must be arranged depending on the decision if patients have to be transported or not. In conclusion it can be stated that in spite of growing technical preconditions the availability of the methods in immobile patients and the diagnostic potency of the techniques have to be examined. (orig.) [de

  14. [Ureteral realignment with the rendezvous procedure in complex ureteral injuries - aspects of technique and our experience].

    Science.gov (United States)

    Brandt, Alexander Sascha; von Rundstedt, F-C; Lazica, D A; Roth, S

    2010-07-01

    The rendezvous procedure for re-establishing ureteral continuity after complex ureteral injuries is introduced and we present our experience with this technique. Aspects of the technique are described in a detailed step-by-step instruction using intraoperative radiographs. We evaluated our patient data from 1998 until 2009 for cases in which the rendezvous procedure was attempted. The rendezvous procedure was used in a total of 11 patients. Realignment was successful in 10 cases (90.9 %) and the initial nephrostomy could be removed. In 3 of 7 cases postoperative removal of the JJ ureteric stent was successful. In 7 patients the final surgical ureter reconstruction was performed after a medium period of 7 months. 5 cases of ureteroneocystostomy and 2 cases of reconstruction of the ureter either with colon or ileum segments were accomplished. In 1 patient a permanent maintenance of the DJ ureteral stent was necessary. Ureteral realignment with the rendezvous procedure enables disposition of the ureteral stent in many cases, exclusively antegrade or retrograde procedures failed. By this means nephrostomy could be spared as a temporary or permanent solution and a better chance of restitutio ad integrum could be realised. Georg Thieme Verlag KG Stuttgart * New York.

  15. Diagnostic techniques for measuring temperature transients and stress transients in the first wall of an ICF reactor

    International Nuclear Information System (INIS)

    Melamed, N.T.; Taylor, L.H.

    1983-01-01

    The primary challenge in the design of an Inertial Confinement Fusion (ICF) power reactor is to make the first wall survive the frequent explosions of the pellets. Westinghouse has proposed a dry wall design consisting of steel tubes coated with tantalum. This report describes the design of a test chamber and two diagnostic procedures for experimentally determining the reliability of the Westinghouse design. The test chamber simulates the x-ray and ion pulse irradiation of the wall due to a pellet explosion. The diagnostics consist of remote temperature sensing and surface deformation measurements. The chamber and diagnostics can also be used to test other first-wall designs

  16. Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Murari, Andrea [Consorzio RFX - CNR, ENEA, INFN, Universita di Padova, Acciaierie Venete SpA,Corso Stati Uniti 4, 35127 Padova (Italy)

    2015-07-01

    . With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

  17. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Science.gov (United States)

    Saha, Bhaskar; Goebel, kai

    2007-01-01

    Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and theoretically sound approach to the modern Condition- Based Maintenance (CBM)/Prognostic Health Management (PHM) paradigm. The application of the Bayesian techniques to regression and classification in the form of Relevance Vector Machine (RVM), and to state estimation as in Particle Filters (PF), provides a powerful tool to integrate the diagnosis and prognosis of battery health. The RVM, which is a Bayesian treatment of the Support Vector Machine (SVM), is used for model identification, while the PF framework uses the learnt model, statistical estimates of noise and anticipated operational conditions to provide estimates of remaining useful life (RUL) in the form of a probability density function (PDF). This type of prognostics generates a significant value addition to the management of any operation involving electrical systems.

  18. New Diagnostic, Launch and Model Control Techniques in the NASA Ames HFFAF Ballistic Range

    Science.gov (United States)

    Bogdanoff, David W.

    2012-01-01

    This report presents new diagnostic, launch and model control techniques used in the NASA Ames HFFAF ballistic range. High speed movies were used to view the sabot separation process and the passage of the model through the model splap paper. Cavities in the rear of the sabot, to catch the muzzle blast of the gun, were used to control sabot finger separation angles and distances. Inserts were installed in the powder chamber to greatly reduce the ullage volume (empty space) in the chamber. This resulted in much more complete and repeatable combustion of the powder and hence, in much more repeatable muzzle velocities. Sheets of paper or cardstock, impacting one half of the model, were used to control the amplitudes of the model pitch oscillations.

  19. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    Science.gov (United States)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview

  20. Integration technique of digital I and C replacement and its Critical Digital Review procedure

    International Nuclear Information System (INIS)

    Huang, Hui-Wen; Yang, Wen-Long

    2013-01-01

    Highlights: ► A digital I and C replacement integration technique have been developed. ► Establishment of Nuclear Power Plant Digital Replacement Integration Guideline. ► Preliminary Investigation on I and C System Digitalization. ► Evaluation on I and C System Digitalization. ► Establishment of I and C System Digitalization Architectures. -- Abstract: Institute of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin–Shan (CS) NPP, Kuo–Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) procedure. The digital I and C replacement integration technique includes: (1) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR-1011710 (2005) “Handbook for Evaluating Critical Digital Equipment and Systems” which was published by the Electric Power Research Institute (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SV and V), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of

  1. Malignancies in blood-forming organs following diagnostic and therapeutic procedures: a review

    International Nuclear Information System (INIS)

    Hodgin, J.D.; Webster, P.D.

    1976-01-01

    Ionizing radiation used for diagnosis or therapy has been associated with an increased incidence of malignancies of blood-forming organs. The increased incidence of hematopoietic malignancies following exposure to ionizing radiation obtained in the course of occupation, diagnosis and therapy of disease, or as a weapon of war is documented. The natural occurrence and the induced progression to acute leukemia of polycythemia rubra vera, Hodgkin's disease, multiple myeloma, Di Guglielmo's disease, and reticuloendothelial malignancies are discussed. The status of transplantation and immunodeficiency states and their relationship to acute leukemia is reviewed. Finally, drugs, toxins, and the use of cytotoxic radiomimetic agents for nonmalignant purposes are shown to lead to the development of acute leukemia. Background information relevant to the proper use of future diagnostic and therapeutic modalities is provided

  2. Cardiac diseases - their clinical features, diagnostic procedures and questions to the radiologist

    Energy Technology Data Exchange (ETDEWEB)

    Maisch, B.

    1983-09-01

    When diagnosing cardiac diseases non-invasively either by radiology, radionuclide studies or echocardiography each method has its values and problems. In coronary artery disease exercise stress testing with or without thallium-201 perfusion scintigraphy, the demonstration of coronary artery calcification and echocardiography are valuable non-invasive methods. Only by coronary arteriography, however, can the degree of stenosis, its localisation and its operability be determined. In heart muscle diseases X-ray and radionuclide angiocardiography demonstrate cardiac dilatation and diminished left ventricular function. In addition echocardiography is the method of choice to distinguish dilated from hypertrophic (obstructive or non obstructive) cardiomyopathy. Pericardial diseases are diagnosed most effectively by echocardiography and, more expensively, by computer tomography. In neoplastic pericardial effusions computer tomography assesses mediastinal tumors most effectively. In valvular heart disease the classical chest X-ray is still of great importance, but echocardiography is more specific and more sensitive. Invasive diagnostic measures (heart catherization) are still mandatory in most valvular diseases.

  3. Lung cancer: Diagnostic procedures and therapeutic management, with special reference to radiotherapy

    International Nuclear Information System (INIS)

    Scarantino, C.W.

    1985-01-01

    This book on lung cancer provides a good overview of this very common cause of death in both men and women. The eight chapters in this book review a number of aspects of the disease including epidemiology, pathology, diagnostic workup, and treatment by radiation and chemotherapy. The two introductory chapters provide a summary of the epidemiology of this disease and an approach to each individual patient. Included are chapters on the many methods of treating lung cancer and the results of clinical trials as well as a brief discussion given to surgical treatment. A chapter on clinical research is directed primarily at ideas relating to chemotherapy. This brief book provides an overview of the many aspects involved in diagnosing and treating lung cancer

  4. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  5. All-Arthroscopic Revision Eden-Hybinette Procedure for Failed Instability Surgery: Technique and Preliminary Results.

    Science.gov (United States)

    Giannakos, Antonios; Vezeridis, Peter S; Schwartz, Daniel G; Jany, Richard; Lafosse, Laurent

    2017-01-01

    To describe the technique of an all-arthroscopic Eden-Hybinette procedure in the revision setting for treatment of a failed instability procedure, particularly after failed Latarjet, as well as to present preliminary results of this technique. Between 2007 and 2011, 18 shoulders with persistent instability after failed instability surgery were treated with an arthroscopic Eden-Hybinette technique using an autologous bicortical iliac crest bone graft. Of 18 patients, 12 (9 men, 3 women) were available for follow-up. The average follow-up was 28.8 months (range, 15 to 60 months). A Latarjet procedure was performed as an index surgery in 10 patients (83%). Two patients (17%) had a prior arthroscopic Bankart repair. Eight patients (67%) obtained a good or excellent result, whereas 4 patients (33%) reported a fair or poor result. Seven patients (58%) returned to sport activities. A positive apprehension test persisted in 5 patients (42%), including 2 patients (17%) with recurrent subluxations. The Rowe score increased from 30.00 to 78.33 points (P Instability Index score showed a good result of 28.71% (603 points). The average anterior flexion was 176° (range, 150° to 180°), and the average external rotation was 66° (range, 0° to 90°). Two patients (16.67%) showed a progression of glenohumeral osteoarthritic changes, with each patient increasing by one stage in the Samilson-Prieto classification. All 4 patients (33%) with a fair or poor result had a nonunion identified on postoperative computed tomography scan. An all-arthroscopic Eden-Hybinette procedure in the revision setting for failed instability surgery, although technically demanding, is a safe, effective, and reproducible technique. Although the learning curve is considerable, this procedure offers all the advantages of arthroscopic surgery and allows reconstruction of glenoid defects and restoration of shoulder stability in this challenging patient population. In our hands, this procedure yields good

  6. Interventional diagnostic breast procedures; Diagnostische Mammainterventionen

    Energy Technology Data Exchange (ETDEWEB)

    Bick, U. [Inst. fuer Radiologie, Universitaetsklinikum Charite, Berlin (Germany); Dept. of Radiology, The Univ. of Chicago (United States); Diekmann, S.; Diekmann, F. [Inst. fuer Radiologie, Universitaetsklinikum Charite, Berlin (Germany)

    2001-09-01

    The comprehensive survey describes in great detail the indications, performance, and advantages and drawbacks of the various biopsy and localization techniques available today for interventional diagnostic evaluation of lesions of the breast. (orig./CB) [German] Die Feinnadelaspirationszytologie ist einfach und rasch durchfuehrbar, ist jedoch insbesondere in der Hand von unerfahrenen Untersuchern mit einer relativ hohen Rate von nicht auswertbaren und falsch-negativen Befunden verbunden. Das Verfahren wird am haeufigsten bei soliden oder zystischen Herdbefunden eingesetzt, die palpabel oder sonographisch nachweisbar sind. Bei inadaequatem Zellmaterial muss eine erneute Biopsie, ggf. mit einem anderen Verfahren, erfolgen. Die Nadelstanzbiopsie ist heutzutage das Verfahren der Wahl bei mammographisch oder sonographisch sichtbaren soliden Herdbefunden. Das Verfahren ist einfach und kostenguenstig durchfuehrbar und weist bei soliden Herdbefunden eine extrem hohe Sensitivitaet und Spezifitaet auf. Bei Mikroverkalkungen sollten immer ausreichend viele Stanzen (5 und mehr) entnommen werden. Bei Stanzbiopsien besteht grundsaetzlich die Gefahr einer Unterschaetzung des histologischen Befundes (ADH statt DCIS, in situ statt invasiv). Bei Diagnose ADH in der Stanzbiopsie sollte eine Exzision des Befundes erfolgen. Die vakuumassistierte Stanzbiopsie ist besonders beeignet zur Biopsie von unklaren Mikroverkalkungen, da durch die groessere entnommene Gewebemenge eine hoehere Spezifitaet und Sensitivitaet erreicht werden kann. Fuer MR-gesteuerte Biopsien hat dieses Verfahren den Vorteil, dass die Nadel nur einmal platziert werden muss. Die stereotaktische Exzisionsbiopsie ist ein relativ teures und invasives Verfahren, das insbesondere zur diagnostischen Abklaerung von unklaren Mikroverkalkungen eingesetzt wird. Hierbei steht das Verfahren in direkter Konkurrenz zur vakuumassistierten Stanzbiopsie. Inwieweit es fuer die stereotaktische Exzisionsbiopsie wirklich ein

  7. Calculation of entrance exposed area from recorded images in cardiac diagnostic and interventional procedures

    International Nuclear Information System (INIS)

    Bibbo, G.; Balman, D.

    2000-01-01

    With increasing number of interventional radiological procedures performed on patients of all ages, it is important to determine the skin entrance dose of patients to limit the side effects of radiation. In most cases the skin dose is measured using thermoluminescent detectors (TLD). However, these detectors need to be placed in the radiation field on the skin of the patient, which may interfere with the procedure. Also, not all radiological practices are equipped with TLD readers which are expensive or have staff with the appropriate knowledge and expertise to be able to make use of TLD. The alternative to TLD is to use the dose area product (DAP) measured with a diamentor fitted to the angiography x-ray equipment. The difficulties in using DAP to calculate skin dose is that the irradiated area of the skin is not known. The area could change in size and location during the procedure as the radiologist/medical specialist varies the collimation and region of interest. For angiography equipment the distance between the anode and image intensifier is variable, as is the height of the examination table. The only point of reference is the isocentre. With recorded images it is possible to determine the irradiated area of the patient at the isocentre plane using the stenosis algorithm. The recorded image is calibrated such that it corresponds to the physical size in the plane of the isocentre. For non-recorded images, it may be necessary to assume that collimation has not changed and that the irradiated area is the same as that shown on the recorded images. The Women's and Children's Hospital has a Toshiba DFP2000 Biplane Digital Imaging system used for all cardiac and general angiography and interventional procedures. With this system the exposure factors (kVp, mA, field sizes) are recorded with the images. The source to image distance (SID), magnification factor (calibration factor of the recorded images) and angle of rotation are displayed on the Display Panel of the

  8. Gel instillation sonohysterography (GIS) and saline contrast sonohysterography (SCSH): comparison of two diagnostic techniques.

    Science.gov (United States)

    Bij de Vaate, A J M; Brölmann, H A M; van der Slikke, J W; Emanuel, M H; Huirne, J A F

    2010-04-01

    To compare gel instillation sonohysterography (GIS) with saline contrast sonohysterography (SCSH) as diagnostic methods for the evaluation of the uterine cavity. A prospective cohort study was performed at the Department of Obstetrics and Gynecology of the VU University Medical Center, Amsterdam, between September 2007 and April 2008. We included 65 women suspected of having an intrauterine abnormality with an indication for SCSH/GIS. First SCSH and subsequently GIS were performed in all women. Distension of the uterine cavity, image quality, visualization of intrauterine abnormalities and pain experienced on a visual analog scale (VAS score) were recorded for both procedures. The mean distension with GIS was 9.0 mm and with SCSH it was 8.5 mm (P = 0.15). The mean image quality, on a scale from 0 to 5, for SCSH was 4.0 and for GIS it was 3.6 (P = 0.01). No difference was found for the visualization of intrauterine abnormalities, and the VAS scores for pain experienced on SCSH and GIS were 1.5 and 1.6, respectively (P = 0.62). The image quality of SCSH is slightly better than that of GIS. This difference is likely to be attributable to the presence of air bubbles in the gel. The small difference in uterine cavity distension in favor of GIS and comparable stable distension during at least 4 min make GIS a suitable alternative for SCSH if air bubbles can be prevented. Copyright 2009 ISUOG. Published by John Wiley & Sons, Ltd.

  9. Degree of vertical integration between the undergraduate program and clinical internship with respect to cervical and cranial diagnostic and therapeutic procedures taught at the canadian memorial chiropractic college.

    Science.gov (United States)

    Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle

    2012-01-01

    The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009-2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and "muscle" adjustments. There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction.

  10. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  11. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Data.gov (United States)

    National Aeronautics and Space Administration — Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and...

  12. The role of choline (Cho) in the diagnostics and differentiation of brain tumours with HMRS technique

    International Nuclear Information System (INIS)

    Sobiecka, B.; Urbanik, A.

    2009-01-01

    Background: The aim of the research was a comprehensive analysis of Cho concentration and Cho/Cr, NAA/Cho, NAA/Cho+Cr ratios for the purposes of the diagnostics and differentiation of brain tumours (the type of the pathological lesion in patients with brain tumours) with the use of HMRS technique. Material/Methods: The HMRS examinations were performed with the use of the MRI Signa Excite 1.5 T system, in PRESS technique (TR = 1500 ms, TE = 35 ms) and involved 100 patients with brain tumours (age range: 18 to 81 yrs, mean age 50.61). Spectra were taken from three different locations: tumour centre, the tumour edge and contralateral unchanged cerebral tissue. All patients underwent surgery followed by histopathological analysis, on the basis of which two groups were separated (benign tumours, malignant tumours - 50 cases each). Additionally, 30 healthy volunteers in the age of 20 to 79 years (mean age 40.8) were examined. Results: The comparison of the examined patients with the control group revealed significantly higher Cho concentrations in patients with brain tumours. The analysis of Cho concentration was also performed with consideration of the age factor (under and over 60 years of age). Significantly lower mean Cho concentrations were discovered in a group of patients under 60 years of age. The analysis of Cho concentrations and Cho/Cr ratios reveled statistical significance for two factors: voxel location factor and the type of the pathological lesion. The average of Cho concentration and Cho/Cr ratios were higher in the group of patients with malignant tumours. The highest Cho concentrations and Cho/Cr ratios were observed in the tumour centre. The relative NAA/Cho and NAA/Cho+Cr ratios were statistically significant when taking into consideration the voxel location factor only. The results received from contralateral normal cerebral tissue (the internal model) were compared with control group (the external model). Mean values of Cho concentration were

  13. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  14. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    International Nuclear Information System (INIS)

    Welzel, S; Rousseau, A; Davies, P B; Roepcke, J

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 μm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared

  15. Interventional diagnostic procedures on the thorax and mediastinum under CT control

    International Nuclear Information System (INIS)

    Stoyanov, K.; Zakhariev, A.; Kalev, D.; Balev, B.; Dimov, D.; Mitishev, I.; Radkov, I.; Yanchev, Ya.

    1991-01-01

    Results are reported of 70 transthoracic aspiration biopsies (TTAB) made under ultrasound, X-ray and computed tomographic (CT) control. The technique of performing the manipulation is described. Special attention is paid on the preliminary preparation of the patient and its realization by a crew consisting in an interventional X-ray physician, a terapeutist, a cytopatologist and a surgical nurse. The most frequently observed complication is pneumothorax, so that very important is the preparedness of the crew for catether decompression if necessary. Advantages of TTAB made under CT control are pointed out. 12 refs., 3 figs

  16. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    Science.gov (United States)

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  18. Staff and patient absorbed doses due to diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Tabei, F.; Neshandar Asli, I.; Aghamiri, S.M.; Arbabi, K.

    2004-01-01

    Background: annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a physical parameter for quantification of ALARA law in nuclear medicine department. Materials and methods: as a part of nationwide study, this paper reports the staff and patient absorbed dose equivalents from diagnostic nuclear medicine examinations performed in four nuclear medicine department during 1999-2002. The type and frequency of examinations in each department were determined directly from hospital medical reports. Staff absorbed doses equivalents were calculated from regular personal dosimeter reports. Results: the total number of examinations increased by 16.7 % during these years. Annual patient collective dose equivalent increased about 13.0 % and the mean effective dose equivalent per exam was 3.61 ± 0.07 mSv. Annual total staff absorbed dose equivalent (total of 24 radiation workers) in four departments increased from 40.45 mSv to 47.81 mSv during four years that indicates an increase of about 20.6 %. The average of annual ratios of staff to patient effective dose equivalents in four departments were 1.83 x 10 -3 , 1.04 x 10 -3 , 3.28 x 10 -3 and 3.24 x 10 -3 , respectively, within a range of 0.9 x 10 -3 - 4.17 x 10 -3 . The mean value of ratios in four years was about 2.24 x 10 -3 ± 1.09 x 10 -3 that indicates the staff dose of about two 1000 th of patient dose. Conclusion: The mean value of ratios in four years was about 1.89 x 10 -3 ± 0.95 x 10 -3 indicating the staff dose of about one 1000 th of the patient dose. The staff to patient absorbed dose equivalent ratio could be used as a quantitative parameter for describing ALARA law in radiation protection and

  19. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-09-15

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  20. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2013-01-01

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  1. Photographic paper X-ray procedure - a simple technique for the visualisation of osseous norm variations and malformations

    International Nuclear Information System (INIS)

    Markert, K.; Wirth, I.; Reinhold-Richter, L.

    1983-01-01

    On the basis of osseous norm variations and malformations, a simple X-ray procedure by means of photographic paper which can be applied in every institute of pathology is demonstrated. The quality of the photographs permits the assessment of skeletal changes which are of diagnostic importance. (author)

  2. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  3. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  4. Influence of preceding diagnostic and therapeutic procedures on the radioiodine therapy of benign thyroid diseases

    International Nuclear Information System (INIS)

    Rendl, J.; Boerner, W.

    1991-01-01

    Before and until 3 weeks after application of nonionic CA iodine and the 20-min-technetium-thyroid-uptake was measured in serum and urine in 23 euthyroid patients, which were given intravenously nonionic CA during heart catheterization. Concerning the possible influence of iodine contamination on a subsequent radioiodine therapy the following aspects result from the study: the time interval between application of CA and therapy has to be at least 4-6 weeks to avoid dilution of the radioiodine by iodine being released from the contrast agents. The thyroid-uptake of Technetium or Iodine after administration of CA is not constant over time but reaches its original value only in a gradual way (60% of the initial value 3 weeks after the CA were given); that means, the iodine-uptake during, radioiodine therapy can be higher than it was at the time the dose was calculated. Concerning the possible influence of preceding therapeutic procedures on the therapy with radioiodine the pretreatment with antithyroid drugs plays the most important role. Antithyroid drugs of the thiourylene group have been shown by many study groups to have a radioprotective effect. Other large studies however could not demonstrate any effect of antithyroid medication on the results of radioiodine therapy. All studies so far existing have in common that they are not strongly randomized with regard to the patient groups, because generally only in severe cases of hyperthyroidism additional antithyroid drug treatment has been employed, therefore it might be the case that the radioprotective effect of antithyroid drugs may be caused only by selection artifacts. The contradictory results of the different studies justify the practical way in so far as there are no reasonable objections against the pretreatment with antithyroid drugs to restore euthyroidism before starting the therapy with radioiodine. (orig./MG) [de

  5. The need for culture sensitive diagnostic procedures

    NARCIS (Netherlands)

    Zandi, Tekleh; Havenaar, Johan M.; Limburg-Okken, Annechien G.; van Es, Hans; Sidali, Salah; Kadri, Nadia; van den Brink, Wim; Kahn, Rene S.

    Objective We examine the procedural validity of a standardized instrument for the diagnosis of psychotic disorders in Morocco. Method Twenty-nine patients from Casablanca, Morocco, with a psychotic or mood disorder were examined using the Comprehensive Assessment of Symptoms and History (CASH) an

  6. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    Directory of Open Access Journals (Sweden)

    Thomas Meyer

    2016-08-01

    Full Text Available The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT in medical samples. Nucleic acid amplification tests (NAATs are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM should include evaluation of lymphogranuloma venereum (LGV by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs or rapid diagnostic tests (RDTs are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  7. Oncologic applications of diagnostic imaging techniques

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1995-01-01

    Before appropriate therapy can be instituted for a cancer patient, the presence and extent of tumor must be evaluated. Deciding which imaging technique to use depends on tumor location, type, and biologic behavior. Conventional radiography provides important information at a relatively low cost compared with other imaging modalities. Ultrasound is a valuable adjunct to radiography, but does not replace it because both imaging modalities provide unique information. Nuclear medicine procedures contribute additional, unique data by providing physiological information, but specificity is lacking. Both CT and MRI provide images with exquisite anatomic detail, but availability and cost prohibit their general use

  8. "Non-filling" procedures for lip augmentation: a systematic review of contemporary techniques and their outcomes.

    Science.gov (United States)

    Moragas, Joan San Miguel; Vercruysse, Herman Junior; Mommaerts, Maurice Y

    2014-09-01

    Ideal lip augmentation techniques have good longevity, low complication rates, and optimal functional and aesthetic results. No systematic review is currently available regarding the efficacy of lip augmentation techniques. This review will focus only on non-filling procedures for lip augmentation (NFPLAs). Current databases Elsevier Science Direct, PubMed, HighWire Press, Springer Standard Collection, SAGE, DOAJ, Sweetswise, Free E-Journals, Ovid Lippincott Williams & Wilkins, Willey Online Library Journals and Cochrane Plus were scrutinized and relevant article reference sections were studied for additional publications. The search heading sequence used was ("Lip" or "Mouth" or "Perioral" or "Nasolabial") and ("Augmentation" or "Enhancement" or "Surgery" or "Lift" or "V-Y" or "Corner"). Exclusion criteria applied to 6436 initial keyword-search retrievals yielded 12 articles. Eight more articles were retrieved from reference sections, for a total of 18 papers assessed. Only one article made a direct comparison of efficacy between two surgical techniques for lip augmentation, and none directly compared complications associated with different NFPLAs. Although this systematic review revealed a lack of quality data in comparing the efficacy and complications among different NFPLAs, it is important to review and pool the existing studies to better suggest proper treatment to patients. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  10. A REVIEW ON DIAGNOSTIC TECHNIQUES FOR BRUCELLOSIS

    African Journals Online (AJOL)

    User

    2014-01-01

    Jan 1, 2014 ... Brucellosis presents with many clinical manifestation that make its diagnosis a difficult task. Ever since the report of the first serologic test for brucellosis, a definitive diagnostic technique has been actively pursued. The most widely used methods of diagnosis are based on serology, which measures the.

  11. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chirag [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Vicini, Frank A., E-mail: fvicini@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2011-11-15

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  12. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    International Nuclear Information System (INIS)

    Shah, Chirag; Vicini, Frank A.

    2011-01-01

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer–related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2–65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  13. In-cylinder pressure-based direct techniques and time frequency analysis for combustion diagnostics in IC engines

    International Nuclear Information System (INIS)

    D’Ambrosio, S.; Ferrari, A.; Galleani, L.

    2015-01-01

    Highlights: • Direct pressure-based techniques have been applied successfully to spark-ignition engines. • The burned mass fraction of pressure-based techniques has been compared with that of 2- and 3-zone combustion models. • The time frequency analysis has been employed to simulate complex diesel combustion events. - Abstract: In-cylinder pressure measurement and analysis has historically been a key tool for off-line combustion diagnosis in internal combustion engines, but online applications for real-time condition monitoring and combustion management have recently become popular. The present investigation presents and compares different low computing-cost in-cylinder pressure based methods for the analyses of the main features of combustion, that is, the start of combustion, the end of combustion and the crankshaft angle that responds to half of the overall burned mass. The instantaneous pressure in the combustion chamber has been used as an input datum for the described analytical procedures and it has been measured by means of a standard piezoelectric transducer. Traditional pressure-based techniques have been shown to be able to predict the burned mass fraction time history more accurately in spark ignition engines than in diesel engines. The most suitable pressure-based techniques for both spark ignition and compression ignition engines have been chosen on the basis of the available experimental data. Time–frequency analysis has also been applied to the analysis of diesel combustion, which is richer in events than spark ignited combustion. Time frequency algorithms for the calculation of the mean instantaneous frequency are computationally efficient, allow the main events of the diesel combustion to be identified and provide the greatest benefits in the presence of multiple injection events. These algorithms can be optimized and applied to onboard diagnostics tools designed for real control, but can also be used as an advanced validation tool for

  14. Genetic risk from diagnostic X-ray procedures

    International Nuclear Information System (INIS)

    Stephan, G.

    1980-01-01

    This essay introduces epidemiologic studies concerned with the question whether diagnostic X-ray procedures might be the cause of an increased genetic risk. All studies have selected Down's syndrome (mongolism) as genetic indicator. They indiscriminately present the opinion of the respective author. Approximately one half of the studies conclude that radiation exposure will not influence the spontaneous incidence of Down's syndrome in diagnostics, the other half finds a positive relationship between frequent radiation exposure and the incidence of the syndrome. For various reasons, explained in detail, the results of the studies under discussion are suitable for forming hypotheses, but should not be viewed as providing evidence. (orig.) [de

  15. Radiofrequency ablation of chondroblastoma: procedure technique, clinical and MR imaging follow up of four cases

    Energy Technology Data Exchange (ETDEWEB)

    Christie-Large, M.; Evans, N.; Davies, A.M.; James, S.L.J. [Royal Orthopaedic Hospital Foundation Trust, Department of Radiology, Birmingham (United Kingdom)

    2008-11-15

    The aim of this study is to describe the procedure technique, clinical and imaging outcomes of patients treated with radiofrequency ablation for chondroblastoma. Four patients (female/male, 3:1; mean age, 13 years; age range; 9-16 years) underwent the procedure. All had pre-operative magnetic resonance imaging (MRI) and symptomatic, biopsy-proven chondroblastomas (two proximal femur, two proximal tibia). The lesion size ranged from 1.5 to 2.5 cm in maximal dimension (mean size, 1.8 cm). Bone access was gained with a Bonopty biopsy needle system (mean number of radiofrequency needle placements, 5; mean ablation time, 31 min). Clinical and MRI follow-up was available in all cases (mean, 12.25 months; range, 5-18 months). All patients reported resolution of symptoms at 2-6 weeks post ablation. At their most recent clinical follow-up, three patients remained completely asymptomatic with full return to normal activities and one patient had minor local discomfort (different pain pattern) that was not limiting activity. All four patients' follow-up MRI studies demonstrated resolution of the oedema pattern around the lesion and temporal evolution of the internal signal characteristics with fatty replacement. Radiofrequency ablation for chondroblastoma provides an alternative to surgical curettage, and we have demonstrated both a clinical improvement in symptoms and the follow-up MRI appearances. (orig.)

  16. Development Procedure in Mutation Induction and Tracer Technique for Good Agriculture Practices for Under used Crops

    International Nuclear Information System (INIS)

    Faiz Ahmad; Rusli Ibrahim; Khairuddin Abdul Rahim

    2015-01-01

    Under used crops are those crop species which have high potential value in the supply of important raw material for secondary economy sector in food processing. The yield production of new Under used crops varieties can be used as an important input in food production process for export products. The optimum production cost can be minimized since the price of raw material supplied from agriculture sector is cheaper compared with the international markets. Agriculture output can be increased through the development of Under used crops using radiation mutagenesis and tracer technique for good agricultural practices. This paper work will discuss the development procedure of mutation induction method which includes irradiation of samples such as seeds of groundnut and in vitro shoots of banana using gamma rays and application of N-15 for nutrient use efficiency and screening of potential mutant lines with high yield and resistance to drought. These management practices using established procedures of water and nutrient use efficiency will be recommended to the growers. (author)

  17. Patients exposure assessment for radiographic procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Stankovic, K.; Lazarevic, Dj.; Ciraj-Bjelac, O.)

    2007-01-01

    In this work the results of dose assessment for the most frequent radiographic procedures in diagnostic radiology are shown. Entrance surface doses were assessed for 7 radiographic procedures. Three hospitals, six x-ray units in total, were enrolled in investigation. Patient doses were estimated based on results of x-ray tube output measurements. Finally, doses were compared with Diagnostic reference level. Higher dose values were observed for chest examinations. In comparison with results from other countries, doses from this procedure in Serbia are significantly higher. Estimated doses for other procedures were well below Diagnostic reference levels [sr

  18. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    Directory of Open Access Journals (Sweden)

    Axel Poulet

    2016-01-01

    Full Text Available Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts.

  19. Evaluation of radiation protection in nuclear medicine diagnostic procedures

    International Nuclear Information System (INIS)

    Mohammed, Ezzeldien Mohammed Nour

    2013-05-01

    This study conducted to evaluate the radiation protection in nuclear medicine diagnostic procedures in four nuclear medicine departments in Sudan. The evaluated procedures followed in these departments were in accordance with the standards, International Recommendations and code of practice for radiation protection in nuclear medicine. The evolution included the optimum design for diagnostic nuclear medicine departments, dealing with radioactive sources, quality assurance and quality control, training and responsibilities for radiation worker taking into account economic factors in Sudan. Evaluation of radiation protection procedures in diagnostic investigations was carried out by taken direct measurements of dose rate and the contamination level in some areas where radiation sources, radiation workers and public are involved. Designated questionnaires covered thirteen areas of radiation protection based on inspection check list for nuclear medicine prepared by the International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine (AAPM) were used in the evaluation. This questionnaire has been Filled by Radiation Protection Officer (RPO), nuclear medicine technologist, nuclear medicine specialist in the nuclear medicine departments. Four hospitals, two governmental hospital and two private hospitals, have been assisted, the assessment shows that although the diagnostic nuclear medicine department in Sudan are not applying a fully safety and radiation protection procedures, but the level of radiation dose and the contamination level were found within acceptable limits. The private hospital D scored the higher level of protection (85.25%) while the governmental hospital C scored the lower level of protection (59.02%). Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a proper radiation protection

  20. Incompressible Navier-Stokes and parabolized Navier-Stokes solution procedures and computational techniques

    Science.gov (United States)

    Rubin, S. G.

    1982-01-01

    Recent developments with finite-difference techniques are emphasized. The quotation marks reflect the fact that any finite discretization procedure can be included in this category. Many so-called finite element collocation and galerkin methods can be reproduced by appropriate forms of the differential equations and discretization formulas. Many of the difficulties encountered in early Navier-Stokes calculations were inherent not only in the choice of the different equations (accuracy), but also in the method of solution or choice of algorithm (convergence and stability, in the manner in which the dependent variables or discretized equations are related (coupling), in the manner that boundary conditions are applied, in the manner that the coordinate mesh is specified (grid generation), and finally, in recognizing that for many high Reynolds number flows not all contributions to the Navier-Stokes equations are necessarily of equal importance (parabolization, preferred direction, pressure interaction, asymptotic and mathematical character). It is these elements that are reviewed. Several Navier-Stokes and parabolized Navier-Stokes formulations are also presented.

  1. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Determination of hydrogen concentration and blister characterization

    International Nuclear Information System (INIS)

    2009-03-01

    Heavy water reactors (HWRs) comprise significant numbers of today's operating nuclear power plants, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes, are an important factor in ensuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Intercomparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the framework of the IAEA's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of IAEA's project on advanced technologies for HWRs. The objective of the CRP was to compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP participants investigated the capability of different techniques to detect and characterize flaws. During the second phase participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in zirconium alloys. The intention was to identify the most effective pressure tube inspection and diagnostic methods and to identify further development needs. The organizations which participated in phase 2 of this CRP are: - Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL), Chalk River Laboratories (CRL), Canada; - Bhabha Atomic Research Centre (BARC), India; - Korea Atomic Energy Research Institute (KAERI), Republic of Korea; - National Institute for Research and Development for Technical Physics (NIRDTP), Romania; - Nuclear Non-Destructive Testing Research and Services (NNDT), Romania. IAEA-TECDOC-1499

  2. Complex polarimetric and spectral techniques in diagnostics of blood plasma of patients with ovarian cancer as a preliminary stage molecular genetic screening

    Science.gov (United States)

    Grzegorzewski, B.; Peresunko, O. P.; Yermolenko, S. B.

    2018-01-01

    This work is devoted to the substantiation and selection of patients with ovarian cancer (OC) for the purpose of conducting expensive molecular genetic studies on genotyping. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues. Obtained results showed that the use of spectrophotometry in the range of 1000-3000 cm-1 allowed to establish quantitative parameters of the plasma absorption rate of blood of patients in the third group in different ranges, which would allow in the future to conduct an express analysis of the patient's condition (procedure screening) for further molecular-genetic typing on BRCA I and II.

  3. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  4. A general purpose diagnostic technique for marine diesel engines - Application on the main propulsion and auxiliary diesel units of a marine vessel

    International Nuclear Information System (INIS)

    Lamaris, V.T.; Hountalas, D.T.

    2010-01-01

    Diesel engines are widely used in marine applications (i.e. propulsion and auxiliaries) except from a few cases where gas or steam turbines are used. This is the result of their high efficiency, power concentration and reliability compared to other compatible or alternative power sources. The proper and efficient operation of the engines (main engine and diesel generator units) in marine applications is critical, and therefore techniques or systems that determine engine current condition and detect potential faults are extremely important. Furthermore, it is advantageous when such techniques can be applied on different engine configurations and provide reliable results, because on a vessel usually exist diesel engines of different type, i.e. the main propulsion unit is a large low-speed two-stroke diesel engine while the diesel generators are four-stroke medium or high speed engines. In the present work is described and evaluated for the first time the application of an improved diagnostic technique, developed by the authors, on both the main engine and the auxiliary units of a commercial marine vessel. The diagnostic technique is based on a thermodynamic simulation model. The simulation model embedded in the technique has been modified, namely an existing two-zone model is replaced by a multi-zone one. With this modification it is avoided model constant tuning with the operating conditions. This is extremely important for the diagnostic philosophy of the proposed technique. Using data from engine shop tests, the simulation model is calibrated (i.e. model constants are determined) and the engine reference condition is obtained. The simulation model is then used to estimate the current engine condition, using field measurements (i.e. cylinder pressure measurements, periphery data, etc.). From the results it is revealed that the diagnosis method provides detailed information for the operating condition of both engines and the values of parameters that cannot be

  5. Current Techniques of Teaching and Learning in Bariatric Surgical Procedures: A Systematic Review.

    Science.gov (United States)

    Kaijser, Mirjam; van Ramshorst, Gabrielle; van Wagensveld, Bart; Pierie, Jean-Pierre

    The gastric sleeve resection and gastric bypass are the 2 most commonly performed bariatric procedures. This article provides an overview of current teaching and learning methods of those techniques in resident and fellow training. A database search was performed on Pubmed, Embase, and the Education Resources Information Center (ERIC) to identify the methods used to provide training in bariatric surgery worldwide. After exclusion based on titles and abstracts, full texts of the selected articles were assessed. Included articles were reviewed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. In total, 2442 titles were identified and 14 full text articles met inclusion criteria. Four publications described an ex vivo training course, and 6 focused on at least 1 step of the gastric bypass procedure. Two randomized controlled trials (RCT) provided high-quality evidence on training aspects. Surgical coaching caused significant improvement of Bariatric Objective Structured Assessment of Technical Skills (BOSATS) scores (3.60 vs. 3.90, p = 0.017) and reduction of technical errors (18 vs. 10, p = 0.003). A preoperative warm-up increased global rating scales (GRS) scores on depth perception (p = 0.02), bimanual dexterity (p = 0.01), and efficiency of movements (p = 0.03). Stepwise education, surgical coaching, warming up, Internet-based knowledge modules, and ex vivo training courses are effective in relation to bariatric surgical training of residents and fellows, possibly shortening their learning curves. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  6. Procedure and technique critique for tritium enrichment by electrolysis at the IAEA Laboratory (effective November 1976)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1976-11-05

    This publication gives a detailed description of the experimental and calculation procedures for tritium enrichment. Most descriptive sections are divided into 2 parts: Section A describes the procedure in the IAEA laboratory; section B discusses the reasons behind the various procedures, and may indicate alternative acceptable, or in some cases even better, procedures. The description of the equipment focuses on electrolysis cells, cooling system and power supply. Routine procedures are discussed including handling and checking of samples after receipt, 'spike' and blank water, initial sample distillation, preparation of cells and samples for electrolysis, electrolysis and completion of electrolysis (weighing of cells, neutralisation and distillation) and precautions against contaminations (prevention, detection and cure). A list of equipment required for electrolytic enrichment of tritium is provided.

  7. Procedure and technique critique for tritium enrichment by electrolysis at the IAEA Laboratory (effective November 1976)

    International Nuclear Information System (INIS)

    1976-01-01

    This publication gives a detailed description of the experimental and calculation procedures for tritium enrichment. Most descriptive sections are divided into 2 parts: Section A describes the procedure in the IAEA laboratory; section B discusses the reasons behind the various procedures, and may indicate alternative acceptable, or in some cases even better, procedures. The description of the equipment focuses on electrolysis cells, cooling system and power supply. Routine procedures are discussed including handling and checking of samples after receipt, 'spike' and blank water, initial sample distillation, preparation of cells and samples for electrolysis, electrolysis and completion of electrolysis (weighing of cells, neutralisation and distillation) and precautions against contaminations (prevention, detection and cure). A list of equipment required for electrolytic enrichment of tritium is provided

  8. Noninvasive Diagnostic Technique in Stenotic Coronary Atherosclerosis

    Directory of Open Access Journals (Sweden)

    A. Yu. Vasilyev

    2005-01-01

    Full Text Available Objective: to determine the sensitivity and specificity of combined stress echocardiography (EchoCG using dipyri-damole and dobutamine in diagnosing and defining the extent of stenotic coronary lesions in coronary heart disease (CHD in a group of critically ill patients who are unable to perform a physical exercise.Materials and methods: the study included 57 male patients with suspected acute coronary syndrome who underwent stress EchoCG using dipyridamole in high doses in combination with dobutamine, as well as coronary angiography.Results: stress EchoCG could bring up to the diagnostic criteria in all the patients, of whom 9 patients were found at coronary angiography to have no coronary lesion, 34 and 14 patients had one- and many-vessel lesions, respectively. The sensitivity and specificity of combined stress EchoCG were significantly higher than those of EchoCG used in the diagnosis of CHD.Conclusion: stress EchoCG using dipyridamole in combination with dobutamine is a highly informative safe noninvasive technique for diagnosing CHD, its helps to identify patients with atypical acute coronary syndrome and to form a group of patients to be subject to urgent coronarography and angiosurgical intervention. The pattern of segmental contractile disorders at the height of exercise during combined stress Echo-CG makes it possible to define the site of stenotic coronary atherosclerosis with 97.3% sensitivity and to diagnose many-vessel lesion with 100% sensitivity and 100%specificity.

  9. Major femoral vascular access complications after coronary diagnostic and interventional procedures

    DEFF Research Database (Denmark)

    Dencker, Ditte; Pedersen, Frants; Engstrøm, Thomas

    2016-01-01

    surgery within 30 days were collected. Mortality data were collected for minimum 12 months. RESULTS: We identified 130 (0.54%) access complications requiring surgery; 65 pseudoaneurysms (0.28%), 46 arterial occlusions (0.19%), 15 hematomas (nine groin and six retroperitoneal hematomas) (0.06%), and 4...

  10. Xeroderma pigmentosum: diagnostic procedures, interdisciplinary patient care, and novel therapeutic approaches.

    Science.gov (United States)

    Lehmann, Janin; Schubert, Steffen; Emmert, Steffen

    2014-10-01

    Xeroderma pigmentosum (XP) is an autosomal recessive disease, caused by a gene defect in the nucleotide-excision-repair (NER) pathway or in translesional DNA synthesis. At the age of eight, patients already develop their first skin cancers due to this DNA repair defect. In contrast, in the Caucasian population the first tumor formation in UV exposed skin regions occurs at a mean age of 60. The clinical picture among patients suffering from XP is highly diverse and includes signs of accelerated skin aging, and UV-induced skin cancers, as well as ophthalmologic and neurological symptoms. Patients should therefore receive interdisciplinary care. This includes dermatologists, ophthalmologists, ENT specialists, neurologists, and human geneticists. Patients with XP are clinically diagnosed, but this may be supported by molecular-genetic and functional analyses. These analyses allow pinpointing the exact disease-causing gene defect (complementation group assignment, detection of the type and location of the mutation within the gene). The resulting information is already relevant to predict the course of disease and symptoms and probably will be utilized for individualized therapeutic approaches in the future. Recently, enhanced repair of UV photolesions in xeroderma pigmentosum group C cells induced by translational readthrough of premature termination codons by certain antibiotics could be demonstrated. © 2014 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  11. Legal, ethical, and procedural bases for the use of aseptic techniques to implant electronic devices

    Science.gov (United States)

    Mulcahy, Daniel M.

    2013-01-01

    The popularity of implanting electronic devices such as transmitters and data loggers into captive and free-ranging animals has increased greatly in the past two decades. The devices have become smaller, more reliable, and more capable (Printz 2004; Wilson and Gifford 2005; Metcalfe et al. 2012). Compared with externally mounted devices, implanted devices are largely invisible to external viewers such as tourists and predators; exist in a physically protected, thermally stable environment in mammals and birds; and greatly reduce drag and risk of entanglement. An implanted animal does not outgrow its device or attachment method as can happen with collars and harnesses, which allows young animals to be more safely equipped. However, compared with mounting external devices, implantation requires greater technical ability to perform the necessary anesthesia, analgesia, and surgery. More than 83% of publications in the 1990s that used radiotelemetry on animals assumed that there were no adverse effects on the animal (Godfrey and Bryant 2003). It is likely that some studies using implanted electronic devices have not been published due to a high level of unexpected mortality or to aberrant behavior or disappearance of the implanted animals, a phenomenon known as the “file drawer” problem (Rosenthal 1979; Scargle 2000). The near absence of such studies from the published record may be providing a false sense of security that procedures being used are more innocuous than they actually are. Similarly, authors sometimes state that it was unlikely that device implantation was problematic because study animals appeared to behave normally, or authors state that previous investigators used the same technique and saw no problems. Such statements are suppositions if no supporting data are provided or if the animals were equipped because there was no other way to follow their activity. Moreover, such suppositions ignore other adverse effects that affect behavior indirectly, and

  12. Diagnostic procedures, treatments, and outcomes in stroke patients admitted to different types of hospitals.

    Science.gov (United States)

    Asplund, Kjell; Sukhova, Maria; Wester, Per; Stegmayr, Birgitta

    2015-03-01

    In many countries, including Sweden, initiatives have been taken to reduce between-hospital differences in the quality of stroke services. We have explored to what extent hospital type (university, specialized nonuniversity, or community hospital) influences hospital performance. Riksstroke collects clinical data during hospital stay (national coverage 94%). Follow-up data at 3 months were collected using administrative registers and a questionnaire completed by surviving patients (response rate 88%). Structural data were collected from a questionnaire completed by hospital staff (response rate 100%). Multivariate analyses with adjustment for clustering were used to test differences between types of hospitals. The proportion of patients admitted directly to a stroke unit was highest in community hospitals and lowest in university hospitals. Magnetic resonance, carotid imaging, and thrombectomy were more frequently performed in university hospitals, and the door-to-needle time for thrombolysis was shorter. Secondary prevention with antihypertensive drugs was used less often, and outpatient follow-up was less frequent in university hospitals. Fewer patients in community hospitals were dissatisfied with their rehabilitation. After adjusting for possible confounders, poor outcome (dead or activities of daily living dependency 3 months after stroke) was not significantly different between the 3 types of hospital. In a setting with national stroke guidelines, stroke units in all hospitals, and measurement of hospital performance and benchmarking, outcome (after case-mix adjustment) is similar in university, specialized nonuniversity, and community hospitals. There seems to be fewer barriers to organizing well-functioning stroke services in community hospitals compared with university hospitals. © 2015 American Heart Association, Inc.

  13. A standard diagnostic and education procedure for nurses in recognizing the symptoms of aging man

    Directory of Open Access Journals (Sweden)

    Korol Agnieszka

    2017-03-01

    Full Text Available Introduction. In the aging process a weakening of the multiple organ systems and endocrine system occur, which in turn, leads to male hormones deficiency – androgens release, including testosterone. It is believed that the year-to-year, women awareness of the menopausal problems increases, however, their knowledge of the consequences of menopause is still insufficient. Unfortunately, only a small percentage of the population is aware that the same problem can also affect men. Male menopause symptoms are still largely an area of social taboo subject, which is not discussed at all or very little. As a consequence, men are not informed, enlightened, and therefore also ready for the changes that are to take place in themselves and their lives.

  14. Estimating the burden of pneumococcal pneumonia among adults: a systematic review and meta-analysis of diagnostic techniques.

    Directory of Open Access Journals (Sweden)

    Maria A Said

    Full Text Available Pneumococcal pneumonia causes significant morbidity and mortality among adults. Given limitations of diagnostic tests for non-bacteremic pneumococcal pneumonia, most studies report the incidence of bacteremic or invasive pneumococcal disease (IPD, and thus, grossly underestimate the pneumococcal pneumonia burden. We aimed to develop a conceptual and quantitative strategy to estimate the non-bacteremic disease burden among adults with community-acquired pneumonia (CAP using systematic study methods and the availability of a urine antigen assay.We performed a systematic literature review of studies providing information on the relative yield of various diagnostic assays (BinaxNOW® S. pneumoniae urine antigen test (UAT with blood and/or sputum culture in diagnosing pneumococcal pneumonia. We estimated the proportion of pneumococcal pneumonia that is bacteremic, the proportion of CAP attributable to pneumococcus, and the additional contribution of the Binax UAT beyond conventional diagnostic techniques, using random effects meta-analytic methods and bootstrapping. We included 35 studies in the analysis, predominantly from developed countries. The estimated proportion of pneumococcal pneumonia that is bacteremic was 24.8% (95% CI: 21.3%, 28.9%. The estimated proportion of CAP attributable to pneumococcus was 27.3% (95% CI: 23.9%, 31.1%. The Binax UAT diagnosed an additional 11.4% (95% CI: 9.6, 13.6% of CAP beyond conventional techniques. We were limited by the fact that not all patients underwent all diagnostic tests and by the sensitivity and specificity of the diagnostic tests themselves. We address these resulting biases and provide a range of plausible values in order to estimate the burden of pneumococcal pneumonia among adults.Estimating the adult burden of pneumococcal disease from bacteremic pneumococcal pneumonia data alone significantly underestimates the true burden of disease in adults. For every case of bacteremic pneumococcal pneumonia

  15. Diagnostic Tests and Procedures

    Science.gov (United States)

    ... your heart with a stethoscope. This is called auscultation, which means the study of heart sounds. Doctors ... finds that your disease is more serious.) Tags: auscultation , blood pressure , heart valve , x-ray Article Info ...

  16. Medical X-ray techniques in diagnostic radiography. 4. ed.

    International Nuclear Information System (INIS)

    Plaats, G.J. van der; Vijlbrief, P.

    1980-01-01

    A step by step account is given of every aspect of the technical factors involved in the production of X-ray images. Chapter titles include, methods of image formation and laws of projection, sharpness and unsharpness, contrast, perceptibility of detail in the radiographic image-image quality, properties of fluoroscopic screens, radiographic films, intensifying screens and cassettes, image intensification and X-ray television, processing technique, fluoroscopy and radiographic technique in general, special radiographic techniques, radiographic examinations using contrast media, exposure and exposure tables and automatic density control, diagnostic X-ray apparatus, and diagnostic stands and accessories. (C.F.)

  17. A Roadmap of Risk Diagnostic Methods: Developing an Integrated View of Risk Identification and Analysis Techniques

    National Research Council Canada - National Science Library

    Williams, Ray; Ambrose, Kate; Bentrem, Laura

    2004-01-01

    ...), which is envisioned to be a comprehensive reference tool for risk identification and analysis (RI AND A) techniques. Program Managers (PMs) responsible for developing or acquiring software-intensive systems typically identify risks in different ways...

  18. Diagnostics of glass fiber reinforced polymers and comparative analysis of their fabrication techniques with the use of acoustic emission

    Science.gov (United States)

    Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.

    2016-11-01

    Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.

  19. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  20. Laser diagnodent: a comparative study with other diagnostic techniques

    International Nuclear Information System (INIS)

    Godinho, Reugma Rego

    2002-01-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  1. An efficient diagnostic technique for distribution systems based on under fault voltages and currents

    Energy Technology Data Exchange (ETDEWEB)

    Campoccia, A.; Di Silvestre, M.L.; Incontrera, I.; Riva Sanseverino, E. [Dipartimento di Ingegneria Elettrica elettronica e delle Telecomunicazioni, Universita degli Studi di Palermo, viale delle Scienze, 90128 Palermo (Italy); Spoto, G. [Centro per la Ricerca Elettronica in Sicilia, Monreale, Via Regione Siciliana 49, 90046 Palermo (Italy)

    2010-10-15

    Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental components rms values taken from the transient measures of line currents and voltages at the MV/LV substations. The fault location and identification algorithm, proposed by the authors and suitably restated, has been implemented on a microprocessor-based device that can be installed at each MV/LV substation. The speed and precision of the algorithm have been tested against the errors deriving from the fundamental extraction within the prescribed fault clearing times and against the inherent precision of the electronic device used for computation. The tests have been carried out using Matlab Simulink for simulating the faulted system. (author)

  2. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1

    International Nuclear Information System (INIS)

    2006-05-01

    Nuclear power plants with heavy water reactors (HWRs) comprise nine percent of today's operating nuclear units, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Programme (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the frame of the IAEA Department of Nuclear Energy's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of the IAEA's project on advanced technologies for HWRs. The objective of the CRP was to inter-compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP, participants have investigated the capability of different techniques to detect and characterize flaws. During the second phase of this CRP, participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in Zirconium alloys. The intent was to identify the most effective pressure tube inspection and diagnostic methods, and to identify further development needs. The organizations that have participated in this CRP are: - The Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL); Chalk River Laboratories (CRL), Canada; - The Research Institute of Nuclear Power Operations (RINPO), China National Nuclear Corporation (CNNC), China; - Bhabha Atomic Research Centre (BARC), India; - The Korea Electric Power Research Institute (KEPRI), Republic of Korea; - The Korea Atomic Energy

  3. Medial release and lateral imbrication for intractable anterior knee pain: diagnostic process, technique, and results

    Directory of Open Access Journals (Sweden)

    Meldrum AR

    2015-01-01

    Full Text Available Alexander R Meldrum,1 Jeremy R Reed,2 Megan D Dash3 1Department of Surgery, Section of Orthopedic Surgery, University of Calgary, Calgary, AB, Canada; 2Department of Surgery, University of Saskatchewan College of Medicine, Regina, SK, Canada; 3Department of Family Medicine, College of Medicine, University of Saskatchewan, Regina, SK, Canada Purpose: To present two cases of intractable patellofemoral pain syndrome treated with a novel procedure, arthroscopic medial release, and lateral imbrication of the patellar retinaculum. Patients and methods: This case series presents the treatment of three knees in two patients (one bilateral in whom an all-inside arthroscopic medial release and lateral imbrication of the patellar retinaculum was performed. Subjective measurement of pain was the primary outcome measurement, and subjective patellofemoral instability was the secondary outcome measurement. Results: Subjectively the two patients had full resolution of their pain, without any patellofemoral instability. Conclusion: Medial release and lateral imbrication of the patellar retinaculum is a new surgical procedure that has been used in the treatment of intractable patellofemoral pain syndrome. This is the first report of its kind in the literature. While outcome measurements were less than ideal, the patients had positive outcomes, both functionally and in terms of pain. Keywords: anterior knee pain syndrome, chondromalacia patellae, runners knee, patellar chondropathy, patellofemoral dysfunction, patellofemoral tracking disorder

  4. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    Science.gov (United States)

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. The nuclear medical diagnostic procedures at the hospitals in Sofia over a period of ten years - from 1990 to 2000 - structure, number and doses

    International Nuclear Information System (INIS)

    Adelina, P.; Ingilizova, K.; Paskalev, Z

    2003-01-01

    The aim of this study is to analyze the structure and the number of nuclear diagnostic procedures at hospitals in Sofia over a period of ten years (from 1990 to 2000); to calculate the effective doses received by patients; to compare the results from different hospitals. We have developed a form in order to collect the necessary information from hospitals (nuclear laboratories). The information has been collected according to examined organ, applied radioactive pharmaceutical and injected activity (MBq), patient's age and sex. The effective doses have been calculated using transition coefficients for each of the applied radioactive pharmaceuticals and for each of the diagnostic procedures. We have received the information and calculated the doses. We have compared the data from different hospitals (nuclear laboratories). The results show that the doctors in different hospitals have used different radioactive pharmaceuticals and applied different activities for one and the same procedure. (orig.)

  6. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear

    DEFF Research Database (Denmark)

    Reiman, Michael P.; Thorborg, Kristian; Goode, Adam P.

    2017-01-01

    Background: Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Purpose: Summarize and evaluate the diagnostic...... probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings...... decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Clinical Relevance: Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis...

  7. Recommended procedures and techniques for the petrographic description of bituminous coals

    Science.gov (United States)

    Chao, E.C.T.; Minkin, J.A.; Thompson, C.L.

    1982-01-01

    Modern coal petrology requires rapid and precise description of great numbers of coal core or bench samples in order to acquire the information required to understand and predict vertical and lateral variation of coal quality for correlation with coal-bed thickness, depositional environment, suitability for technological uses, etc. Procedures for coal description vary in accordance with the objectives of the description. To achieve our aim of acquiring the maximum amount of quantitative information within the shortest period of time, we have adopted a combined megascopic-microscopic procedure. Megascopic analysis is used to identify the distinctive lithologies present, and microscopic analysis is required only to describe representative examples of the mixed lithologies observed. This procedure greatly decreases the number of microscopic analyses needed for adequate description of a sample. For quantitative megascopic description of coal microlithotypes, microlithotype assemblages, and lithotypes, we use (V) for vitrite or vitrain, (E) for liptite, (I) for inertite or fusain, (M) for mineral layers or lenses other than iron sulfide, (S) for iron sulfide, and (X1), (X2), etc. for mixed lithologies. Microscopic description is expressed in terms of V representing the vitrinite maceral group, E the exinite group, I the inertinite group, and M mineral components. volume percentages are expressed as subscripts. Thus (V)20(V80E10I5M5)80 indicates a lithotype or assemblage of microlithotypes consisting of 20 vol. % vitrite and 80% of a mixed lithology having a modal maceral composition V80E10I5M5. This bulk composition can alternatively be recalculated and described as V84E8I4M4. To generate these quantitative data rapidly and accurately, we utilize an automated image analysis system (AIAS). Plots of VEIM data on easily constructed ternary diagrams provide readily comprehended illustrations of the range of modal composition of the lithologic units making up a given coal

  8. [Evaluation of quality of HIV diagnostic procedures in Poland].

    Science.gov (United States)

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  9. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    Energy Technology Data Exchange (ETDEWEB)

    Molina-Perez, J. [UC, San Diego; Bonacorsi, D. [Bologna U.; Gutsche, O. [Fermilab; Sciaba, A. [CERN; Flix, J. [Madrid, CIEMAT; Kreuzer, P. [CERN; Fajardo, E. [Andes U., Bogota; Boccali, T. [INFN, Pisa; Klute, M. [MIT; Gomes, D. [Rio de Janeiro State U.; Kaselis, R. [Vilnius U.; Du, R. [Beijing, Inst. High Energy Phys.; Magini, N. [CERN; Butenas, I. [Vilnius U.; Wang, W. [Beijing, Inst. High Energy Phys.

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  10. Monitoring techniques and alarm procedures for CMS Services and Sites in WLCG

    International Nuclear Information System (INIS)

    Molina-Perez, J; Sciabà, A; Magini, N; Bonacorsi, D; Gutsche, O; Flix, J; Kreuzer, P; Fajardo, E; Boccali, T; Klute, M; Gomes, D; Kaselis, R; Butenas, I; Du, R; Wang, W

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS; the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  11. Guideline for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016.

    Science.gov (United States)

    2016-10-15

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between the depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large (kissing) tonsils or anatomic airway abnormalities that might increase thepotential for airway obstruction, a clear understanding of the medication's pharmacokinetic and pharmacodynamic effects and drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of staff to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to the presedation level of consciousness before discharge from medical/dental supervision, and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children.

  12. Patient dose assessment in different diagnostic procedures in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Sena, E de; Bejar, M J; Berenguer, R [Servicio de Radiofisica y Proteccion Radiologica, Salamanca (Spain); Ruano, R; Tamayo, P [Servicio de Medicina Nuclear, Hospital Universitario de Salamanca (Spain)

    2001-03-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  13. Patient dose assessment in different diagnostic procedures in nuclear medicine

    International Nuclear Information System (INIS)

    Sena, E. de; Bejar, M.J.; Berenguer, R.; Ruano, R.; Tamayo, P.

    2001-01-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  14. Diagnostic reproducibility of hydatidiform moles: ancillary techniques (p57 immunohistochemistry and molecular genotyping) improve morphologic diagnosis.

    Science.gov (United States)

    Vang, Russell; Gupta, Mamta; Wu, Lee-Shu-Fune; Yemelyanova, Anna V; Kurman, Robert J; Murphy, Kathleen M; Descipio, Cheryl; Ronnett, Brigitte M

    2012-03-01

    Distinction of hydatidiform moles (HMs) from nonmolar specimens (NMs) and subclassification of HMs as complete hydatidiform moles (CHMs) and partial hydatidiform moles (PHMs) are important for clinical practice and investigational studies; yet, diagnosis based solely on morphology is affected by interobserver variability. Molecular genotyping can distinguish these entities by discerning androgenetic diploidy, diandric triploidy, and biparental diploidy to diagnose CHMs, PHMs, and NMs, respectively. Eighty genotyped cases (27 CHMs, 27 PHMs, and 26 NMs) were selected from a series of 200 potentially molar specimens previously diagnosed using p57 immunostaining and genotyping. Cases were classified by 3 gynecologic pathologists on the basis of H&E slides (masked to p57 immunostaining and genotyping results) into 1 of 3 categories (CHM, PHM, or NM) during 2 diagnostic rounds; a third round incorporating p57 immunostaining results was also conducted. Consensus diagnoses (those rendered by 2 of 3 pathologists) were determined. Genotyping results were used as the gold standard for assessing diagnostic performance. Sensitivity of a diagnosis of CHM ranged from 59% to 100% for individual pathologists and from 70% to 81% by consensus; specificity ranged from 91% to 96% for individuals and from 94% to 98% by consensus. Sensitivity of a diagnosis of PHM ranged from 56% to 93% for individual pathologists and from 70% to 78% by consensus; specificity ranged from 58% to 92% for individuals and from 74% to 85% by consensus. The percentage of correct classification of all cases by morphology ranged from 55% to 75% for individual pathologists and from 70% to 75% by consensus. The κ values for interobserver agreement ranged from 0.59 to 0.73 (moderate to good) for a diagnosis of CHM, from 0.15 to 0.43 (poor to moderate) for PHM, and from 0.13 to 0.42 (poor to moderate) for NM. The κ values for intraobserver agreement ranged from 0.44 to 0.67 (moderate to good). Addition of the p57

  15. Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach.

    Science.gov (United States)

    Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario

    2017-08-28

    Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.

  16. Economic appraisal of the angioplasty procedures performed in 2004 in a high-volume diagnostic and interventional cardiology unit.

    Science.gov (United States)

    Manari, Antonio; Costa, Elena; Scivales, Alessandro; Ponzi, Patrizia; Di Stasi, Francesca; Guiducci, Vincenzo; Pignatelli, Gianluca; Giacometti, Paola

    2007-10-01

    Growing interest in the use of drug-eluting stents (DESs) in coronary angioplasty has prompted the Healthcare Agency of the Emilia Romagna Region to draw up recommendations for their appropriate clinical use in high-risk patients. Since the adoption of any new technology necessitates economic appraisal, we analysed the resource consumption of the various types of angioplasty procedures and the impact on the budget of a cardiology department. A retrospective economic appraisal was carried out on the coronary angioplasty procedures performed in 2004 in the Department of Interventional Cardiology of Reggio Emilia. On the basis of the principles of activity-based costing, detailed hospital costs were estimated for each procedure and compared with the relevant diagnosis-related group (DRG) reimbursement. In 2004, the Reggio Emilia hospital performed 806 angioplasty procedures for a total expenditure of euro 5,176,268. These were 93 plain old balloon angioplasty procedures (euro 487,329), 401 procedures with bare-metal stents (euro 2,380,071), 249 procedures with DESs (euro 1,827,386) and 63 mixed procedures (euro 481,480). Reimbursements amounted to euro 5,816,748 (11% from plain old balloon angioplasty, 50% from bare-metal stent, 31% from DES and 8% from mixed procedures) with a positive margin of about euro 680,480 between costs incurred and reimbursements obtained, even if the reimbursement for DES and mixed procedures was not covering all the incurred costs. Analysis of the case-mix of procedures revealed that an overall positive margin between costs and DRG reimbursements was achieved. It therefore emerges that adherence to the indications of the Healthcare Agency of the Emilia Romagna Region for the appropriate clinical use of DESs is economically sustainable from the hospital enterprise point of view, although the DRG reimbursements are not able to differentiate among resource consumptions owing to the adoption of innovative technologies.

  17. Use of serological diagnostic techniques in the control and eradication of caprine arthritis encephalitis: an update

    Directory of Open Access Journals (Sweden)

    Jamili Maria Suhet Mussi

    2015-12-01

    Full Text Available Caprine arthritis encephalitis (CAE is a chronic disease caused by a small ruminant lentivirus (SRLV, which causes significant losses in goat breeding. The actual state of animal infection with SRLV is difficult to determine due to a complex pathogenesis of the virus, including factors such as delayed or intermittent seroconversion in serological tests. Several serological techniques are available for disease diagnosis, such as screening or confirmation tests, which are different in sensitivity and specificity. Regarding the choice of the test to be applied, availability of commercial immunoreagents, team training, antigen used, and cost of techniques must be considered. This review presents the serological methods available for use in different stages of CAE control and eradication programs, and management measures to be adopted in conjunction with serological diagnosis of the disease.

  18. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    Science.gov (United States)

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  19. R20 programme: Development of rock grouting design, techniques and procedures for ONKALO

    International Nuclear Information System (INIS)

    Sievaenen, U.

    2009-02-01

    Posiva Oy constructs an underground research facility ONKALO at Olkiluoto in Eurajoki. ONKALO is planned to be a part of the deep repository for the high level nuclear waste. Posiva Oy set up R20-programme for the years 2006-2008, with the target of having an acceptable grouting methodology in ONKALO. The programme was divided into three projects and the work and results of Technique-project is presented in this report. The implementation of the results (grouting design and execution) was outlined from the project. That work is under the responsibility of construction of the ONKALO-project. The Grouting Technique -project (INKE) studied the grouting experiences obtained from the first 2 km of the ONKALO access tunnel, searched for suitable grouting design approaches, carried out two grouting tests and one pilot grouting test with colloidal silica in ONKALO, analysed the expected grouting conditions in deep rock from the grouting point of view, studied the feasibility of so called optimal design solution in the expected grouting conditions. Based on these studies recommendations concerning the grouting design, design solutions for different rock conditions, grouting procedures, grouting stop criteria, the characterisation methods for grouting purposes, grouting materials and grouting work performance are presented. Swedish Time Stop Grouting, also named Grouting Time-Method was selected to be studied and used in this project and it was further developed. This work compiles the outcome of the project subtasks and presents the recommendations for developing the grouting in ONKALO. The key conclusion of this work are: (1) Grouting Time-method (time stop grouting) alone is not enough to be used as a grouting stop criterion due to the uncertainties related to the source parameters (fracture characteristics, rheological properties of grouts); these cause too high uncertainties when proving the sealing result via the grouting time, (2) due to the uncertainties related to

  20. Procedure for the determination of gap and base ground surface configurations beneath the bottom plate of storage tanks using neutron gauging inspection techniques : including radiation safety procedure and emergency procedure

    International Nuclear Information System (INIS)

    Jaafar Abdullah

    1993-01-01

    The procedure is intended for the neutron gauging inspection of gap between the bottom plate and the foundation of bulk storage tanks, which potentially exhibit uneven sinking of the bottom plate and the foundation. Its describes the requirements for the performance of neutron back scattered inspection techniques (or radiometric non-destructive evaluation techniques), using an isotopic neutron source associated with neutron detecting systems, to detect and size the gap between the bottom plate and the foundations as well as to quantify the presence of hydrogenous materials (e.g. oil or water) underneath the bottom plate. This procedure is not only outline the requirements for the neutron gauging inspection, but also describes the requirements which shall be taken into account in formulating the radiation safety and emergency procedures for the neutron gauging inspection works

  1. Radiation doses from medical diagnostic procedures in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, J E; Lentle, B C; Vo, C [British Columbia Univ., Vancouver, BC (Canada). Dept. of Radiology

    1997-03-01

    This document sets out to record and analyze the doses incurred in Canada from medical procedures involving the use of ionizing radiation in a typical year. Excluded are those doses incurred during therapeutic irradiation, since they differ in scale to such a large degree and because they are used almost exclusively in treating cancer. In this we are following a precedent set by the United Nations Scientific Committee on the Effects of Ionizing Radiation. Although the International Commission on Radiological Protection (ICRP) notes that dose limits should not be applied to medical exposures, it also observes that doses in different settings for the same procedure may vary by as much as two orders of magnitude, and that there are considerable opportunities for dose reductions in diagnostic radiology. Because these data do not stand in isolation the report also encompasses a review of the relevant literature and some background comment on the evolving technology of the radiological sciences. Because there is a somewhat incomplete perception of the changes taking place in diagnostic methods we have also provided some introductory explanations of the relevant technologies. In addition, there is an analysis of at least some of the limitations on the completeness of the data which are reported here. (author).

  2. Radiation doses from medical diagnostic procedures in Canada

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Lentle, B.C.; Vo, C.

    1997-03-01

    This document sets out to record and analyze the doses incurred in Canada from medical procedures involving the use of ionizing radiation in a typical year. Excluded are those doses incurred during therapeutic irradiation, since they differ in scale to such a large degree and because they are used almost exclusively in treating cancer. In this we are following a precedent set by the United Nations Scientific Committee on the Effects of Ionizing Radiation. Although the International Commission on Radiological Protection (ICRP) notes that dose limits should not be applied to medical exposures, it also observes that doses in different settings for the same procedure may vary by as much as two orders of magnitude, and that there are considerable opportunities for dose reductions in diagnostic radiology. Because these data do not stand in isolation the report also encompasses a review of the relevant literature and some background comment on the evolving technology of the radiological sciences. Because there is a somewhat incomplete perception of the changes taking place in diagnostic methods we have also provided some introductory explanations of the relevant technologies. In addition, there is an analysis of at least some of the limitations on the completeness of the data which are reported here. (author)

  3. Osteosynthesis techniques used for mandibular sagittal split osteotomy – history of orthognathic procedures and modern practice.

    Science.gov (United States)

    Nowak, Rafał; Trybek, Grzegorz

    Choosing an appropriate fixation technique after maxillary or mandibular osteotomy is one of the key factors affecting the success of orthognathic surgery. In line with the development of new surgical methods and techniques, the surgeons’ approach to the fixation of bone fragments has evolved accordingly, varying from non-fusion to different osteosynthesis techniques. Advances in medical sciences and medical technologies, have changed our attitudes to bone fragment reduction in orthopaedics and traumatology, and also in maxillofacial surgery. The pivotal underlying principle which determines bone healing – that is proper positioning so as to ensure appropriate contact area and immobilisation so as to ensure osteosynthesis – has remained unchanged for centuries. However, over the years, patient comfort and the predictability of treatment outcomes have vastly improved. The paper provides an overview of the techniques and methods used for the fixation of osteotomized fragments after bilateral sagittal split osteotomy since its introduction by Hugo Obwegeser up to the present day.

  4. Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016.

    Science.gov (United States)

    Coté, Charles J; Wilson, Stephen

    2016-07-01

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between the depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large (kissing) tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction, a clear understanding of the medication's pharmacokinetic and pharmacodynamic effects and drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of staff to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to the presedation level of consciousness before discharge from medical/dental supervision, and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children. Copyright © 2016 American Academy of Pediatric Dentistry and American Academy of Pediatrics. This report is being published concurrently in Pediatric Dentistry July 2016. The articles are identical. Either citation can be used when citing this report.

  5. Proceedings of the National Conference on Energy Resource Management. Volume 1: Techniques, Procedures and Data Bases

    Science.gov (United States)

    Brumfield, J. O. (Editor); Schiffman, Y. M. (Editor)

    1982-01-01

    Topics dealing with the integration of remotely sensed data with geographic information system for application in energy resources management are discussed. Associated remote sensing and image analysis techniques are also addressed.

  6. Assessment Procedures for Narcissistic Personality Disorder: A Comparison of the Personality Diagnostic Questionnaire-4 and Best-Estimate Clinical Judgments

    Science.gov (United States)

    Miller, Joshua D.; Campbell, W. Keith; Pilkonis, Paul A.; Morse, Jennifer Q.

    2008-01-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD)…

  7. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  8. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  9. New diagnostic and therapeutic techniques in the management of pyogenic liver abscesses

    International Nuclear Information System (INIS)

    Ranson, J.H.C.; Madayag, M.A.; Localio, S.A.; Spencer, F.C.

    1975-01-01

    An unexplained increase in the frequency of pyogenic liver abscesses of unknown etiology has, fortunately, been paralleled by significant advances in diagnostic and therapeutic methods. This report reviews experience with 14 patients operated upon at NYU Medical Center since 1971. Eight cases (57 percent) were cryptogenic. Other abscesses were associated with biliary disease (3); abdominal sepsis (2); and trauma (1). Abscesses were present on hospitalization in 12 patients. Clinical findings included fever (101 to 108 F), 100 percent; leucocytosis, 71 percent; anorexia and vomiting, 50 percent; localized tenderness and hepatomegaly, 50 percent; hypoalbuminemia; 86 percent; hypocholesterolemia, 78 percent; elevated SGOT, 71 percent; and elevated aikaline phosphatase, 43 percent. Technetium hepatic scintiscans showed focal defects in 10 of 12 patients (83 percent), but did not detect multiple abscesses in 2 of these. Hepatic arteriography performed in 10 patients was highly accurate, outlining single abscesses in 6 and multiple abscesses in 4. Furthermore, in one patient a false positive scintiscan was demonstrated by negative arteriography, confirmed by autopsy. In 4 patients, arteriography indicated an abscess in the posterior-superior area of the right hepatic lobe. With precise anatomical localization, a transthoracic approach permitted uncomplicated drainage in each case. This approach provides excellent exposure and direct drainage for abscesses in this area. An additional therapeutic adjunct in two patients, with 4 and 11 abscesses each, was postoperative intraportal infusion of antibiotics through the umbilical vein. Thirteen patients (83 percent) recovered, one dying from pulmonary embolism. Primary hepatic abscesses occur with increasing frequency. The methods described allow more precise preoperative diagnosis and direct surgical drainage

  10. Monitoring techniques and alarm procedures for CMS services and sites in WLCG

    CERN Document Server

    Molina-Perez, Jorge Amando

    2012-01-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS; the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator on duty at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is explo...

  11. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Science.gov (United States)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  12. Electroencephalography as a diagnostic technique for canine neurological diseases

    Directory of Open Access Journals (Sweden)

    Wrzosek Marcin

    2016-06-01

    Full Text Available Electroencephalography (EEG is a non-invasive examination method for the assessment of functional central nervous system (CNS disturbances. In human medicine it has a special importance as a diagnostic tool for epilepsy. Although many studies were done on the use of EEG for diagnostics of canine central nervous system disorders, the technique is still not applied routinely. The purpose of this paper was to review the use of the electroencephalography in canine neurological disorders of central nervous system diagnosis and assess the future perspectives of this technique in veterinary medicine.

  13. Degree of vertical integration between the undergraduate program and clinical internship with respect to lumbopelvic diagnostic and therapeutic procedures taught at the canadian memorial chiropractic college.

    Science.gov (United States)

    Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J

    2010-01-01

    The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college.

  14. The impact of altering filling pressures in diagnostic outpatient hysteroscopy on the procedure completion rates and associated pain: a randomised double-blind controlled trial.

    Science.gov (United States)

    Haggag, Hisham M; Hassan, AbdelGany M A

    2016-02-01

    Several studies have compared different distension media and analgesics to optimise the efficiency of outpatient hysteroscopy. However, studies comparing different uterine filling pressures are scarce. The objective of this study was to evaluate and compare different uterine filling pressures during diagnostic outpatient hysteroscopy in an attempt to find the optimal pressure allowing adequate visualisation while minimising pain and increasing patient satisfaction. This was a double-blind randomised controlled trial. A total of 240 women who had diagnostic outpatient hysteroscopy were randomly divided into three equal groups: the uterine filling pressure was 30 mm Hg in group 1, 50 mm Hg in group 2 and 80 mm Hg in group 3. The primary outcome was adequate visualisation, and secondary outcomes were the proportion of completed procedures, pain perceived during the procedure, immediately after the procedure and 30 min later. Adequate visualisation was lower in group 1 (88.7% vs 97.5% and 98.7%; P = 0.009), but was not different between groups 2 and 3 (P > 0.999). The proportion of completed procedures was not different among the groups. There was a progressive increase in pain scores from the lower to the higher pressure groups during the procedure, immediately after the procedure and 30 min after completing the procedure. Uterine filling pressure of 50 mm Hg was associated with better visualisation than 30 mm Hg and lower pain scores than that of 80 mmHg with no difference in the proportion of completed procedures. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  15. Procedures for treating common cause failures in safety and reliability studies: Analytical background and techniques

    International Nuclear Information System (INIS)

    Mosleh, A.; Fleming, K.N.; Parry, G.W.; Paula, H.M.; Worledge, D.H.; Rasmuson, D.M.

    1989-01-01

    Volume I of this report presents a framework for the inclusion of the impact of common cause failures in risk and reliability evaluations. Common cause failures are defined as that subset of dependent failures for which causes are not explicitly included in the logic model as basic events. The emphasis here is on providing procedures for a practical, systematic approach that can be used to perform and clearly document the analysis. The framework and the methods discussed for performing the different stages of the analysis integrate insights obtained from engineering assessments of the system and the historical evidence from multiple failure events into a systematic, reproducible, and defensible analysis. This document, Volume 2, contains a series of appendices that provide additional background and methodological detail on several important topics discussed in Volume I

  16. Preliminary survey on the distribution of medical equipment and frequency of diagnostic and therapeutic procedures in Brazil: a contribution to the UNSCEAR report

    International Nuclear Information System (INIS)

    Biazotto, Bruna; Taboza de Oliveira, Alexandre; Baptista de Freitas, Marcelo

    2008-01-01

    Information about Brazil published in the UNSCEAR 2000 report are still scarce when compared to others countries. In this study, a survey on the distribution of medical equipment (X-ray generators, ultrasound, CT and MRI scanners, nuclear medicine equipment and teletherapy and brachytherapy units) and frequency of diagnostic and therapeutic procedures at the various Brazilian States was carried out. The overall information was obtained from a national database supported by the Brazilian Ministry of Health through the Computer Science Department of the National Health System (SUS - Sistema Unico de Saude). The distribution of equipment and the annual frequency of each type of procedure were analyzed considering the five geographical regions that form the country and their respective population. Temporal and regional trends in the annual frequency of procedures for 2000-2007 were also summarized in this study. National annual frequencies for the total of all medical X-ray examinations (259.0 examinations per 1000 population) were evaluated. Some examples can be given from chest, mammography and CT examinations: 67.4, 30.2 and 7.2 per 1000 population, respectively. In addition, annual frequencies for other modalities of diagnostic imaging have also been estimated: 61.5, 1.6 and 1.4 per 1000 population for ultrasound, nuclear medicine and MRI procedures, respectively. A total of 38.7 therapeutic procedures per 1000 population (teletherapy and brachytherapy) are annually performed in the country. The health services localized in Brazil comprised a total number of 253.1 diagnostic imaging equipment per million population, without considering dental X-ray. Amongst them, X-ray equipment used in common radiological examinations (chest, skull, spine, etc.) stands for 39% (97.7 per million). As expected, a significant decrease in the offer of equipment is observed when technologically more sophisticated equipment is concerned: magnetic resonance (3.5 per million), gamma

  17. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  18. MR-defecography in obstructed defecation syndrome (ODS): technique, diagnostic criteria and grading.

    Science.gov (United States)

    Piloni, V; Tosi, P; Vernelli, M

    2013-10-01

    The aim of this study was to evaluate the use of a magnetic resonance (MR)-based classification system of obstructive defecation syndrome (ODS) to guide physicians in patient management. The medical records and imaging series of 105 consecutive patients (90 female, 15 male, aged 21-78 years, mean age 46.1 ± 5.1 years) referred to our center between April 2011 and January 2012 for symptoms of ODS were retrospectively examined. After history taking and a complete clinical examination, patients underwent MR imaging according to a standard protocol using a 0.35 T permanent field, horizontally oriented open-configuration magnet. Static and dynamic MR-defecography was performed using recognized parameters and well-established diagnostic criteria. Sixty-seven out of 105 (64 %) patients found the prone position more comfortable for the evacuation of rectal contrast while 10/105 (9.5 %) were unable to empty their rectum despite repeated attempts. Increased hiatus size, anterior rectocele and focal or extensive defects of the levator ani muscle were the most frequent abnormalities (67.6, 60.0 and 51.4 %, respectively). An MR-based classification was developed based on the combinations of abnormalities found: Grade 1 = functional abnormality, including paradoxical contraction of the puborectalis muscle, without anatomical defect affecting the musculo-fascial structures; Grade 2 = functional defect associated with a minor anatomical defect such as rectocele ≤ 2 cm in size and/or first-degree intussusception; Grade 3 = severe defects confined to the posterior anatomical compartment, including >2 cm rectocele, second- or higher-degree intussusception, full-thickness external rectal prolapse, poor mesorectal posterior fixation, rectal descent >5 cm, levator ani muscle rupture, ballooning of the levator hiatus and focal detachment of the endopelvic fascia; Grade 4 = combined defects of two or three pelvic floor compartments, including cystocele, hysterocele, enlarged urogenital

  19. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  20. Comparative cost analysis -- computed tomography vs. alternative diagnostic procedures, 1977-1980

    International Nuclear Information System (INIS)

    Gempel, P.A.; Harris, G.H.; Evans, R.G.

    1977-12-01

    In comparing the total national cost of utilizing computed tomography (CT) for medically indicated diagnoses with that of conventional x-ray, ultrasonography, nuclear medicine, and exploratory surgery, this investigation concludes that there was little, if any, added net cost from CT use in 1977 or will there be in 1980. Computed tomography, generally recognized as a reliable and useful diagnostic modality, has the potential to reduce net costs provided that an optimal number of units can be made available to physicians and patients to achieve projected reductions in alternative procedures. This study examines the actual cost impact of CT on both cranial and body diagnostic procedures. For abdominal and mediastinal disorders, CT scanning is just beginning to emerge as a diagnostic modality. As such, clinical experience is somewhat limited and the authors assume that no significant reduction in conventional procedures took place in 1977. It is estimated that the approximately 375,000 CT body procedures performed in 1977 represent only a 5 percent cost increase over use of other diagnostic modalities. It is projected that 2,400,000 CT body procedures will be performed in 1980 and, depending on assumptions used, total body diagnostic costs will increase only slightly or be reduced. Thirty-one tables appear throughout the text presenting cost data broken down by types of diagnostic procedures used and projections by years. Appendixes present technical cost components for diagnostic procedures, the comparative efficacy of CT as revealed in abstracts of published literature, selected medical diagnoses, and references

  1. Comparative analysis of diagnostic accuracy of different brain biopsy procedures

    OpenAIRE

    Jain Deepali; Sharma Mehar; Sarkar Chitra; Gupta Deepak; Singh Manmohan; Mahapatra A

    2006-01-01

    Background: Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. Aims: The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different s...

  2. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  3. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  4. Diagnostic techniques used in controlled thermonuclear research at Harwell

    Energy Technology Data Exchange (ETDEWEB)

    Harding, G N; Dellis, A N; Gibson, A; Jones, B; Lees, D J; McWhirter, R W.P.; Ramsden, S A; Ward, S [UK Atomic Energy Authority, AERE, Harwell (United Kingdom)

    1958-07-01

    This paper is a general survey of the lines along which diagnostic methods (spectroscopy, electrical measurements, and the study of high energy radiations) are developing at Harwell, and indicates the results which have been obtained so far. Many of the techniques are in a rudimentary state, and most of the Zeta experiments are incomplete.

  5. Diagnostic procedures in cardiology: A clinician's guide

    International Nuclear Information System (INIS)

    Warren, J.V.; Lewis, R.P.

    1985-01-01

    This book contains 31 papers. Some of the titles are: Cardiovascular radiology; Nuclear cardiology; echocardiography; The use and conduct of exercise tests; Lipid studies in cardiology; and The practice of cardiology in an era of high technology

  6. Pet birds II. Complementary diagnostic procedures

    International Nuclear Information System (INIS)

    Beregi, A.; Molnar, V.; Felkai, F.; Biro, F.

    1997-01-01

    Microscopical examinations are useful in detecting bacteria from droppings and body fluids. Antimicrobial susceptibility tests are also used to perform antimicrobial therapy. Parasitological examinations can also be done on pet birds. Hematological examinations are not very common because of the difficulties in determining the normal serum values that might vary by species and sexes. The vena cutanea ulnaris is the best vein for drawing blood from a pet bird but nail clipping for this purpose is also widely used. The most common and basic complementary examination method is radiology. Birds can be radiographed without anesthesia. Ventrodorsal and latero-lateral pictures are required. The right positioning and setting the adequate values is the most important. Contrast radiographs can also be made on birds. Endoscopy is widely used for sex determination but also can be used for the examination of abdominal organs. Ultrasound examination of pet birds is not a common method because of the difficulties provided by the air sacs. ECG is not a widely used method either because of the high heart beat frequency of birds. Other methods such as necropsy, cytological, histological and toxicological examinations can also be performed on pet birds

  7. Development of quality control procedures for mass produced and released Bactrocera Philippinensis (Diptera: Tephritidae) for sterile insect technique programs

    International Nuclear Information System (INIS)

    Resilva, S.; Obra, G.; Zamora, N.; Gaitan, E.

    2007-01-01

    Quality control procedures for Bactrocera philippinensis Drew and Hancock 1994 (Diptera: Tephritidae) used in sterile insect technique (SIT) programs were established in the mass rearing facility at the Philippine Nuclear Research Institute. Basic studies on pupal irradiation, holding/packaging systems, shipping procedures, longevity, sterility studies, and pupal eye color determination in relation to physiological development at different temperature regimes were investigated. These studies will provide baseline data for the development of quality control protocols for an expansion of B. philippinensis field programs with an SIT component in the future. (author) [es

  8. Procedures and Techniques for the PSA of Digital I and C System

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Eom, Heung Sup; Jang, Seung Cheol

    2006-01-01

    UCN 5 and 6 nuclear units (OPR-1000) are being constructed and the Korean Next Generation Reactor (APR-1400) is being designed by using digital I and C equipment for the safety functions such as a reactor protection system, an engineered safety feature actuation system, and a safety equipment control system. Even though the use of digital equipment for safety-related functions provides many advantageous features, there are still many arguable safety issues remaining. Design, configuration management and maintenance are important application areas for the probabilistic safety assessment (PSA). Digital I and C systems are natural candidates for PSA applications. From the viewpoint of the PSA, the digital techniques are very different from the conventional techniques of analog I and C systems because of some unique features. This article aims at giving an overview for the important issues of digital system PSA and at presenting the current status of technology development for each issue. Korea Atomic Energy Research Institute (KAERI) has performed an initiative research in order to meet risk information needs for digitalized safety-critical systems in Korea. The technologies presented in this article especially focusing on those developed in the KAERI

  9. A new techniques in the physics of diagnostic radiology

    International Nuclear Information System (INIS)

    Jennings, R.J.

    1987-01-01

    The basic physics involved in the generation of X-rays and in the energy dependence of their interaction with matter are reviewed. Some applications of those ideas in both conventional X-ray imaging and in new imaging techniques are studied. Methods for the optimization of X-ray diagnostic imaging system are discussed. (M.A.C.) [pt

  10. Modern endoscopic techniques of precancerous stomach conditions diagnostics: problems and possibilities

    Directory of Open Access Journals (Sweden)

    Yu.M. Stepanov

    2017-02-01

    (in the antrum, along the small curvature of the stomach diffusely. According to the researchers’ data, the presence of the intestinal metaplasia on the lesser curvature of the stomach has a strong association with cancer risk. The different kinds of endoscopic devices allow diagnostically diffentiate atrophy and intestinal metaplasia of the stomach. Endoscopy white light can’t reliably diagnose stomach precancerous changes, while videoendoscopy with magnifications and narrow band imaging (NBI, according to researchers’ data, significantly improves the diagnosis of this disease. The basis of diagnosis is increasing verification of two main structures: the architectonic subepithelial microvascular network microstructure and mucosal surface, which has a different pattern in the body and antral stomach. But to date there is no common classification of changes to these structures in various pathological changes. There are a large number of classifications of changes in endoscopy with NBI mode and optical zoom: Yagi (2002, M. Dinis-Ribeiro (2003, G.K. Anagnostopoulos et al. (2007, T. Tahara (2009, P. Pimentel-Nunes, M. Dinis-Ribeiro (2012. It is noted that the problem is that NBI with zoom is practically impossible to use in daily clinical practice, the method requires a certain level of knowledge and endoscope type, available only in several centers, as well as the use of sedation for maximum effective inspection.

  11. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

    NARCIS (Netherlands)

    van der Hoorn, Anouk; van Laar, Peter Jan; Holtman, Gea A.; Westerlaan, Henriette E.

    2017-01-01

    Background Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. Purpose As the diagnostic accuracy of MRI techniques to detect tumor residual or

  12. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    Directory of Open Access Journals (Sweden)

    Barbosa JA

    2011-05-01

    Full Text Available José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG, Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.Keywords: cardiovascular risk, endothelium dysfunction, obesity, strain and strain rate, tissue Doppler

  13. Radiation protection problems by diagnostic procedures of pediatric nuclear medicine

    International Nuclear Information System (INIS)

    Kletter, K.

    1994-01-01

    Special dosimetry considerations are necessary in the application of radiopharmaceuticals in pediatric nuclear medicine. The influence of differences in irradiation geometry and biokinetic parameters on the radiation dose in children and adults is discussed. Assuming an equal activity concentration, both factors lead rather to a reduced radiation dose than an increased radiation burden in children compared to adults. However, the same radiation dose in children and adults may lead to a different detriment. This is explained by differences in life expectancy and radiation sensitivity for both groups. From special formulas an age dependent reduction factor can be calculated for the application of radiopharmaceuticals in pediatric nuclear medicine. Radiation exposure to hospital staff and parents from children, undergoing nuclear medicine diagnostic or therapeutic procedures, is low. (author)

  14. Execution techniques for high level radioactive waste disposal. 4. Design and manufacturing procedure of engineered barriers

    International Nuclear Information System (INIS)

    Ogata, Nobuhide; Kosaki, Akio; Ueda, Hiroyoshi; Asano, Hidekazu; Takao, Hajime

    1999-01-01

    Ensuring the physical integrity of engineered barriers for an extremely long time period is necessary for geological disposal of high-level radioactive wastes. This report describes the design process and the designed configurations of both overpack and buffer as engineered barriers. Manufacturing procedure, quality control and inspection methods are also summarized. Carbon steel was selected as a structural material of the overpack and the specification of the overpack was determined assuming disposal in the depths of 1000 m below surface of crystalline rock site. The mixture of bentonite and sand (80% sodium bentonite and 20% silica sand by mass) was selected as material for a buffer from mainly its permeability and characteristics of self-sealing of a gap occurred in construction work. Welding method of a lid onto the main body of the overpack, uniting method of a corrosion-resistance layer and the structural component in the case of a composite overpack and manufacturing procedures of both blocks-type and monolithic-type buffers are also investigated. (author)

  15. Systematic application of flame diagnostics techniques for performance and emissions development of modern combustion systems; Systematischer Einsatz der Flammendiagnostik fuer die Leistungs- und Emissionsentwicklung moderner Brennverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, E.; Beidl, C.; Hirsch, A.; Piock, W. [AVL List GmbH, Graz (Austria)

    2004-07-01

    In engine engineering, the information and benefits gained from optical flame diagnostics, especially in the combination with thermodynamic and CFD analysis of airflow and combustion are well accepted. It is, however, a specific challenge to implement techniques which are well established in basic engine R and D into the processes of series development or engine calibration. Any technique taken over from successfull predevelopment applications, is expected to equally well support series development. But in order to do this, it must also be suited to easily blend into the procedures of standard multicylinder engine tests. Development speed and results quality improve consideraly, whenever engineers within their routine engine tests gain knowledge about and evaluation of flame properties which allow identification of possible improvements of combustion efficiency, power density and emissions in an early, upfront development phase. Diagnostic systems employed for such tasks make use of fiber optic sensors which in spark ignited engines may be implanted into the bodies of sensor spark plugs. Their mechanic, thermal and electric properties comply with those of the originals, thus enabling their continuous use on the test bed. The arrangement of standard fiber optic channels allows flame radiation monitoring either within the axial proximity of the sensor plug, or of the entire combustion chamber compression volume. Signal recording and signal analysis is accomplished with Visiolution system techniques. Test results are evaluated on the basis of Visiolution algorithms. Data reduction schemes provide numerical figures of merit, describing, e. g. direction, velocity and symmetry of a spark ignited flame kernel. When knock center distribution is analysed, actual distribution statistics are checked against best concept distributions, whenever diffusion flames are detected against expectations of ideal premixed flames, their position, timing and intensity is evaluated. Such

  16. The problem of sexual imbalance and techniques of the self in the Diagnostic and Statistical Manual of Mental Disorders.

    Science.gov (United States)

    Flore, Jacinthe

    2016-09-01

    This article examines the problematization of sexual appetite and its imbalances in the development of the Diagnostic and Statistical Manual of Mental Disorders (DSM) in the twentieth and twenty-first centuries. The dominant strands of historiographies of sexuality have focused on historicizing sexual object choice and understanding the emergence of sexual identities. This article emphasizes the need to contextualize these histories within a broader frame of historical interest in the problematization of sexual appetite. The first part highlights how sexual object choice, as a paradigm of sexual dysfunctions, progressively receded from medical interest in the twentieth century as the clinical gaze turned to the problem of sexual appetite and its imbalances. The second part uses the example of the newly introduced Female Sexual Interest/Arousal Disorder in the DSM-5 to explore how the Manual functions as a technique for taking care of the self. I argue that the design of the Manual and associated inventories and questionnaires paved the way for their interpretation and application as techniques for self-examination. © The Author(s) 2016.

  17. Reduction of radiation doses in leg lengthening procedures by means of audit and computed tomography scanogram techniques

    International Nuclear Information System (INIS)

    Romanowski, C.A.J.; Sprigg, A.; Underwood, A.C.

    1994-01-01

    Children with congenital bone dysplasias may benefit from leg lengthening procedures. Such procedures, by necessity, require frequent and regular imaging. It is necessary to minimize the total radiation dose to these patients, and particularly the dose to the gonads. In the present study, the films of 13 patients who had completed leg lengthening procedures were reviewed. The number of films was assessed together with the use of appropriate gonad shielding. In a second part of the study, thermoluminescent dosemeter measurements of radiation doses to a phantom were made for both plain radiographs (with and without gonad protection) and computed tomography (CT) scanograms. The results show that audit plays an important role in assessing radiographic practice with respect to accurate placement of gonad protection and confirm that a significant dose reduction can be accomplished by careful use of this lead shielding. Dose reduction can also be achieved by using alternative radiographic techniques such as CT scanograms. (author)

  18. Diagnostic value of renal clearance techniques using iodo-hippuran /sup 131/I and /sup 99m/-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Hoer, G [Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

    1976-01-01

    Methods and clinical indications of divided renal clearance determination using /sup 131/I-hippuran are presented and their value as a diagnostic tool in urology is shown by two case reports. For quantitative assessment of renal function we prefer the whole body clearance (with partial shielding of kidneys and bladder) which obviates the necessity of the theoretical assumption of compartmental distribution of radiopharmaceuticals. Using simplified clearance techniques only based on analysis of plasma disappearance curves (slope clearance one- and two-compartment model), clinically useful results are also obtainable, especially in follow up studies. The evaluation of tubular and glomerular kidney function by simultaneous application of /sup 131/I-hippuran and sup(99m)Tc-DTPA is suitable for estimation of filtration fraction in patients with urological and nephrological diseases. Even with regard to therapy and follow up studies of urinary tract tuberculosis, remarkable dignostic informations may be achieved.

  19. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  20. Verification of the helioseismology travel-time measurement technique and the inversion procedure for sound speed using artificial data

    Energy Technology Data Exchange (ETDEWEB)

    Parchevsky, K. V.; Zhao, J.; Hartlep, T.; Kosovichev, A. G., E-mail: akosovichev@solar.stanford.edu [Stanford University, HEPL, Stanford, CA 94305 (United States)

    2014-04-10

    We performed three-dimensional numerical simulations of the solar surface acoustic wave field for the quiet Sun and for three models with different localized sound-speed perturbations in the interior with deep, shallow, and two-layer structures. We used the simulated data generated by two solar acoustics codes that employ the same standard solar model as a background model, but utilize different integration techniques and different models of stochastic wave excitation. Acoustic travel times were measured using a time-distance helioseismology technique, and compared with predictions from ray theory frequently used for helioseismic travel-time inversions. It is found that the measured travel-time shifts agree well with the helioseismic theory for sound-speed perturbations, and for the measurement procedure with and without phase-speed filtering of the oscillation signals. This testing verifies the whole measuring-filtering-inversion procedure for static sound-speed anomalies with small amplitude inside the Sun outside regions of strong magnetic field. It is shown that the phase-speed filtering, frequently used to extract specific wave packets and improve the signal-to-noise ratio, does not introduce significant systematic errors. Results of the sound-speed inversion procedure show good agreement with the perturbation models in all cases. Due to its smoothing nature, the inversion procedure may overestimate sound-speed variations in regions with sharp gradients of the sound-speed profile.

  1. Verification of the helioseismology travel-time measurement technique and the inversion procedure for sound speed using artificial data

    International Nuclear Information System (INIS)

    Parchevsky, K. V.; Zhao, J.; Hartlep, T.; Kosovichev, A. G.

    2014-01-01

    We performed three-dimensional numerical simulations of the solar surface acoustic wave field for the quiet Sun and for three models with different localized sound-speed perturbations in the interior with deep, shallow, and two-layer structures. We used the simulated data generated by two solar acoustics codes that employ the same standard solar model as a background model, but utilize different integration techniques and different models of stochastic wave excitation. Acoustic travel times were measured using a time-distance helioseismology technique, and compared with predictions from ray theory frequently used for helioseismic travel-time inversions. It is found that the measured travel-time shifts agree well with the helioseismic theory for sound-speed perturbations, and for the measurement procedure with and without phase-speed filtering of the oscillation signals. This testing verifies the whole measuring-filtering-inversion procedure for static sound-speed anomalies with small amplitude inside the Sun outside regions of strong magnetic field. It is shown that the phase-speed filtering, frequently used to extract specific wave packets and improve the signal-to-noise ratio, does not introduce significant systematic errors. Results of the sound-speed inversion procedure show good agreement with the perturbation models in all cases. Due to its smoothing nature, the inversion procedure may overestimate sound-speed variations in regions with sharp gradients of the sound-speed profile.

  2. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  3. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  4. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  5. An Experimental Technique for Structural Diagnostic Based on Laser Vibrometry and Neural Networks

    Directory of Open Access Journals (Sweden)

    Paolo Castellini

    2000-01-01

    Full Text Available In recent years damage detection techniques based on vibration data have been largely investigated with promising results for many applications. In particular, several attempts have been made to determine which kind of data should be extracted for damage monitoring.

  6. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  7. Procedures and techniques for closure of near surface disposal facilities for radioactive waste

    International Nuclear Information System (INIS)

    2001-12-01

    The overall objective of this report is to provide Member States with guidance on planning and implementation of closure of near surface disposal facilities for low and intermediate level radioactive waste. The specific objectives are to review closure concepts, requirements, and components of closure systems; to discuss issues and approaches to closure, including regulatory, economic, and technical aspects; and to present major examples of closure techniques used and/or considered by Member States. Some examples of closure experience from Member States are presented in the Appendix and were indexed separately

  8. Competence and lastingness in specialized clinical laboratories: technical report about requirements concerning quality of users competence and used processes in immunochemical diagnostic procedures using isotopic and non-isotopic tracer technologies

    International Nuclear Information System (INIS)

    Wiegel, B.

    2005-01-01

    From the citizens view this technical report about immunochemical diagnostic procedures using radioactive and nonradioactive tracer technologies describes the requirements in special laboratory diagnostics concerning competency and process control. Governmental or administrational obligations of inspecting both skill and sites to guarantee patients security are pointed out. (orig.)

  9. Persistent groin pain following a trans-obturator sling procedure for stress urinary incontinence: a diagnostic and therapeutic challenge

    NARCIS (Netherlands)

    Hazewinkel, Menke H.; Hinoul, Piet; Roovers, Jan-Paul

    2009-01-01

    Groin pain after a tension-free vaginal tape-obturator (TVT-O) procedure can occur but mostly disappears within 4 weeks. Persistent groin pain is extremely rare and there is a paucity of literature on how to diagnose and manage this adverse event. We present two cases with severe persistent groin

  10. Progress in diagnostic techniques for SC [superconducting] cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of afew exceptional examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. In this paper we will direct our attention to discussions of recent developments in diagnostic techniqeus, such as thermometry in superfluid helium, and scanning laser acoustic microscopy. 18 refs., 12 figs

  11. From a genetic innovation to mass health programmes: the diffusion of Down's Syndrome prenatal screening and diagnostic techniques in France.

    Science.gov (United States)

    Vassy, Carine

    2006-10-01

    Down's Syndrome prenatal diagnostic and screening techniques have spread widely in France over the last 30 years and are now part of the routine clinical practice of prenatal care. These techniques, which originated in the field of genetics, ultrasonography and biochemistry, were the first to provide the possibility of choosing the features of the foetus, or at least to reject some of its characteristics. They lead to new norms of healthy foetuses and a progressive acceptance of medical abortions. The aim of this paper is to understand how the use of these tests has been generalised in France despite scientific controversies about their risks and ethical questioning about a potential renewal of eugenics. It analyses the representations of public needs that have been articulated by key players in the scientific and medical fields. This research explores political and administrative decision making processes to understand how progressively widening public access to prenatal testing has been organised and funded. The results highlight the scientific and political role of biomedical researchers, the forms of involvement of health authorities and politicians, and the passive participation of the vast majority of the users. The paper also examines the characteristics of the French health system that facilitated the generalised use of the technology.

  12. Noninvasive Remote Sensing Techniques for Infrastructures Diagnostics

    Directory of Open Access Journals (Sweden)

    Angelo Palombo

    2011-01-01

    Full Text Available The present paper aims at analyzing the potentialities of noninvasive remote sensing techniques used for detecting the conservation status of infrastructures. The applied remote sensing techniques are ground-based microwave radar interferometer and InfraRed Thermography (IRT to study a particular structure planned and made in the framework of the ISTIMES project (funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme. To exploit the effectiveness of the high-resolution remote sensing techniques applied we will use the high-frequency thermal camera to measure the structures oscillations by high-frequency analysis and ground-based microwave radar interferometer to measure the dynamic displacement of several points belonging to a large structure. The paper describes the preliminary research results and discusses on the future applicability and techniques developments for integrating high-frequency time series data of the thermal imagery and ground-based microwave radar interferometer data.

  13. Evaluation of the Acridine Orange Fluorescence Technique and the Indirect Fluorescent Antibody as Diagnostic Tests for Tropical Theileriosis

    Directory of Open Access Journals (Sweden)

    Mahmoud

    2011-06-01

    Full Text Available This study was carried out to evaluate the use of acridine orange fluorescence technique on blood slides as a rapid diagnostic test for tropical theileriosis in comparison with the Giemsa-stained thin blood film technique. Also the indirect fluorescent antibody test has been employed for the serodiagnosis of tropical theileriosis. The study was carried out on 62 young and 48 adult Friesian cattle suffering from clinical tropical theileriosis in Qassim Region, Central Saudi Arabia, during the period from August 2006 to July 2008. For control, blood samples were also obtained from 25 young and 25 adult, clinically healthy, Friesian cattle, selected at random from different dairy farms in Qassim Region. Thin blood films were fixed with methanol and stained with Giemsa and acridine orange and were examined by two independent microbiologists. There was 100% correlation in the interpretation of slides stained with Giemsa and acridine orange both with respect to positivity and negativity, between the two microbiologists. It is concluded that if facilities are available acridine orange is a valuable alternative for screening tropical theileriosis. The method may also have potential value in the diagnosis of Theileria parva, which causes East Coast fever, and also other Theileria species. Results of the present study also showed that IFA test was not found sufficiently sensitive and specific as has been reported earlier. [Vet. World 2011; 4(8.000: 341-344

  14. Selection of suitable diagnostic techniques for an RF atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Kong, M.G.; Deng, X.T.

    2001-01-01

    As an early report of our study, this paper summaries the RF atmospheric pressure plasma system we intend to characterize and a number of diagnostic techniques presently under assessment for our plasma rig. By discussing the advantages and disadvantages of these diagnostic techniques at this meeting, we hope to gain feedback and comments to improve our choice of appropriate diagnostic techniques as well as our subsequent application of these techniques to nonthermal RF atmospheric pressure plasmas

  15. The diagnostic value of double-contrast-technique cystography in the evaluation of benign and malignant lesions of the urinary bladder

    International Nuclear Information System (INIS)

    Beyer, D.; Koester, R.; Schuett, H.

    1979-01-01

    Cystography by double-contrast-technique as simple and quick method of evaluating benign and malignant lesions of the urinary bladder is being described. 301 examinations were reviewed and are being discussed in regard to diagnostic value, indication, complication and radiation exposure of this method. A few typical cases are being demonstrated to illustrate the value of this method in the spectrum of other diagnostic methods in the workup of urinary bladder lesions. (orig.) [de

  16. A critical analysis of penile enhancement procedures for patients with normal penile size: surgical techniques, success, and complications.

    Science.gov (United States)

    Vardi, Yoram; Har-Shai, Yaron; Harshai, Yaron; Gil, Tamir; Gruenwald, Ilan

    2008-11-01

    Most men who request surgical penile enhancement have a normal-sized and fully functional penis but visualize their penises as small (psychological dysmorphism). The aim of this review is to describe the various reported techniques and to provide the available scientific data on the success and complication rates of penile enhancement procedures. We performed an extensive systematic review based on a search of the MEDLINE database for articles published between 1965 and 2008. The following key words were used: penis, enhancement, enlargement, phalloplasty, reconstruction, girth, lengthening, and augmentation. Only English-language articles that were related to penile surgery and dysmorphobia were sought. We excluded articles in which fewer than five cases were described and articles in which the type of surgical treatment and the outcome were not clear. Of the 176 papers found, 34 were selected and critically analyzed. We found only a small number of well-designed and comprehensive studies, and most of the published articles reported data that were obtained from small cohorts of patients. The more recently published studies presented better methodologies and descriptions of the surgical techniques than did the older publications. In general, penile enhancement surgery can cause a 1-2-cm increase in penile length and a 2.5-cm augmentation of penile girth. Unwanted outcomes and complications, namely penile deformity, paradoxical penile shortening, disagreeable scarring, granuloma formation, migration of injected material, and sexual dysfunction were reported frequently in these studies. Disappointing short- and long-term patient satisfaction rates following these procedures were also reported in most studies. To date, the use of cosmetic surgery to enlarge the penis remains highly controversial. There is a lack of any standardization of all described procedures. Indications and outcome measures are poorly defined, and the reported complications are unacceptably high

  17. A clinicopathological study of various oral cancer diagnostic techniques

    Directory of Open Access Journals (Sweden)

    G Ulaganathan

    2017-01-01

    Full Text Available Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis.

  18. Diagnostic techniques in cerebral artery occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huber, P

    1972-01-01

    In two-thrids of the cases of cerebral artery occlusions ophthalmodynamotry, thermography, and the fluorescein test are sufficient. In cases where these give insufficient data, scintigraphy is the preferred screening method. For determination of the regional blood flow /sup 133/Xe is used. Angiographic investigation, however, is the method that gives the most clinically valuable data. The techniques used and the risks inherent in the method are described. (JSR)

  19. Abductive diagnostic procedure based on an and/or/not graph for expected behaviour: application to a gas turbine

    Energy Technology Data Exchange (ETDEWEB)

    Fuster, P. [Dept. Mat. and Infor. UIB, Palma de Mallorca (Spain)] Ligeza, A. [Faculty of Electrical Engineering, Automation and Electrics, Technical University of Cracow (Poland)] Martin, J.A. [LEA-SICA: LAAS-CNRS Toulouse, France and IIiA-UdG Girona (Spain)

    1998-12-31

    In this presentation the diagnostic of technical systems is adressed by considering first of all their expected normal behaviour. The formalism that is used is called AND/OR/NOT causal graphs. This approach can be regarded as an extension of abductive models. A symptom can be True. False or Unknown, it can be represented by a propositional formula. The nodes are partitioned into: Manifestations, that characterize each type of misbehaviour, Elementary diagnosis, that correspond to single faulty states and Intermediate, these last are observable or not partial symptoms. An illustration about the on-line diagnosis of a gas turbine shows also some of the steps leading to a causal graph modelisation in which this diagnosis methodology has been applied. (orig.) 5 refs.

  20. Abductive diagnostic procedure based on an and/or/not graph for expected behaviour: application to a gas turbine

    Energy Technology Data Exchange (ETDEWEB)

    Fuster, P. [Dept. Mat. and Infor. UIB, Palma de Mallorca (Spain)] Ligeza, A. [Faculty of Electrical Engineering, Automation and Electrics, Technical University of Cracow (Poland)] Martin, J.A. [LEA-SICA: LAAS-CNRS Toulouse, France and IIiA-UdG Girona (Spain)

    1997-12-31

    In this presentation the diagnostic of technical systems is adressed by considering first of all their expected normal behaviour. The formalism that is used is called AND/OR/NOT causal graphs. This approach can be regarded as an extension of abductive models. A symptom can be True. False or Unknown, it can be represented by a propositional formula. The nodes are partitioned into: Manifestations, that characterize each type of misbehaviour, Elementary diagnosis, that correspond to single faulty states and Intermediate, these last are observable or not partial symptoms. An illustration about the on-line diagnosis of a gas turbine shows also some of the steps leading to a causal graph modelisation in which this diagnosis methodology has been applied. (orig.) 5 refs.

  1. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  2. Diagnostic procedure on brake pad assembly based on Young's modulus estimation

    International Nuclear Information System (INIS)

    Chiariotti, P; Santolini, C; Tomasini, E P; Martarelli, M

    2013-01-01

    Quality control of brake pads is an important issue, since the pad is a key component of the braking system. Typical damage of a brake pad assembly is the pad–backing plate detachment that affects and modifies the mechanical properties of the whole system. The most sensitive parameter to the damage is the effective Young's modulus, since the damage induces a decrease of the pad assembly stiffness and therefore of its effective Young's modulus: indeed its variation could be used for diagnostic purposes. The effective Young's modulus can be estimated from the first bending resonance frequency identified from the frequency response function measured on the pad assembly. Two kinds of excitation methods, i.e. conventional impulse excitation and magnetic actuation, will be presented and two different measurement sensors, e.g. laser Doppler vibrometer and microphone, analyzed. The robustness of the effective Young's modulus as a diagnostic feature will be demonstrated in comparison to the first bending resonance frequency, which is more sensitive to geometrical dimensions. Variability in the sample dimension, in fact, will induce a variation of the resonance frequency which could be mistaken for damage. The diagnostic approach has been applied to a set of undamaged and damaged pad assemblies showing good performance in terms of damage identification. The environmental temperature can be an important interfering input for the diagnostic procedure, since it influences the effective Young's modulus of the assembly. For that reason, a test at different temperatures in the range between 15 °C and 30 °C has been performed, evidencing that damage identification technique is efficient at any temperature. The robustness of the Young's modulus as a diagnostic feature with respect to damping is also presented. (paper)

  3. Fusion alpha loss diagnostic for ITER using activation technique

    Czech Academy of Sciences Publication Activity Database

    Bonheure, G.; Hult, M.; González de Orduña, R.; Vermaercke, P.; Murari, A.; Popovichev, S.; Mlynář, Jan

    2011-01-01

    Roč. 86, 6-8 (2011), s. 1298-1301 ISSN 0920-3796. [Symposium on Fusion Technology (SOFT) /26th./. Port o, 27.09.2010-01.10.2010] Institutional research plan: CEZ:AV0Z20430508 Keywords : ITER * fusion product * burning plasma diagnostics * alpha losses * activation technique Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002778

  4. Kinetic and diagnostic studies of molecular plasmas using laser absorption techniques

    NARCIS (Netherlands)

    Welzel, S.; Rousseau, A.; Davies, P.B.; Röpcke, J.

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 µm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has

  5. New perspective for radiation protection in diagnostic procedure in Paraguay

    International Nuclear Information System (INIS)

    Sosky, R.A.; Gamarra, M.

    2001-01-01

    The Government in Paraguay approved by Decree Law 10754, dated October 6, 2000, its National Regulation on Basic Safety Standards for Radiation Protection and the Safety of Radiation Sources, based on the IAEA Safety Standards 115. The primary goal of Patient Protection is to ensure that both Regulatory Authorities and all Responsible parties in Medical Practices observe procedural process in conducting their responsibilities on regulatory and administrative affairs. On one side the Government, 'Department de Proteccion Radiologica', under the Health Ministry and Comision Nacional de Energia Atomica, and on the other side, the medical practitioner who prescribes or conducts diagnostic or therapeutic treatment, both ensure that the exposure of patients be the minimum. This document describes how the Regulatory Authorities intend to implement this recent act and on the other hand take the advantage of this Conference to understand better this subject, especially on the following subjects: essential requirement for licensing, inspection and enforcement programme in the country's capital and in the interior, where there are more difficulties; workers and medical training and lessons learned applying to developing countries. (author)

  6. Analysis of heat and mass transfers in two-phase flow by coupling optical diagnostic techniques

    International Nuclear Information System (INIS)

    Lemaitre, P.; Porcheron, E.

    2008-01-01

    During the course of a hypothetical accident in a nuclear power plant, spraying might be actuated to reduce static pressure in the containment. To acquire a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, non-intrusive optical measurements have to be carried out simultaneously on both phases. The coupling of global rainbow refractometry with out-of-focus imaging and spontaneous Raman scattering spectroscopy allows us to calculate the local Spalding parameter B M , which is useful in describing heat transfer associated with two-phase flow. (orig.)

  7. Analysis of heat and mass transfers in two-phase flow by coupling optical diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lemaitre, P.; Porcheron, E. [Institut de Radioprotection et de Surete Nucleaire, Saclay (France)

    2008-08-15

    During the course of a hypothetical accident in a nuclear power plant, spraying might be actuated to reduce static pressure in the containment. To acquire a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, non-intrusive optical measurements have to be carried out simultaneously on both phases. The coupling of global rainbow refractometry with out-of-focus imaging and spontaneous Raman scattering spectroscopy allows us to calculate the local Spalding parameter B{sub M}, which is useful in describing heat transfer associated with two-phase flow. (orig.)

  8. Radioisotopic and thermographic imaging of the lower limbs oedema - comparison diagnostic techniques

    International Nuclear Information System (INIS)

    Stepien, A.; Pawlus, J.; Nowak, E.; Kulka, J.; Gielzycki, J.; Kraft, O.

    2005-01-01

    In this paper, authors achieved comparison between lymphoscintigraphy and thermography in patients with limbs oedema. It allow to determinate current role of lymphoscintigraphy and verify useful of thermography in limbs oedema diagnosis. Analysis included 60 patients with the lower limbs oedema. Each patients Doppler duplex scan and thermographic study was performed. Additionally, 10 patients were classified to the lymphoscintigraphy. Thermography: In studies camera ThermaCAM S60 (FLIR SYSTEM) were used. Infrared radiation detector was 320 x 240 uncooled microbolometers with thermal resolution - 0.08 o C (for 30 o C). Lymphoscintigraphy: Each patient received subcutaneous, in the second web space, Nanosis (schering) labeled 99m Tc. Dynamic data acquisition has been started immediately after injection the radiotracer to the both extremities using digital gamma camera X Ring (Mediso). Static study of whole body was performed after 1.5 hour. Thermal disorders were observed in 58 patients. On the base ultrasound and clinical examinations 10 patients were classified to lymphoscintigraphy. In this group in 5 cases traits lymphatic insufficient were observed. Thermographic study in group of patients with scintigraphic disorders was showed regional hypothermia, with small regions of hypothermia in tissues included oedema. Lymphoscintigraphy is a useful and indispensable tool in oedema diagnosis. In patients with insufficient of lymphatic system, thermography comparison to lymphoscintigraphy, in clinical diagnosis did not influence on the future diagnosis and therapeutics proceedings. Regional hyperthermic disorders in patients with limbs oedema, who had negative results of examinations (Doppler duplex scan and lymphoscintigraphy), could indicate on inflammatory complications. In cases of venous insufficient thermography allow to visualize specific venous disorders. (author)

  9. Using Counter Insurgency Tactics, Techniques and Procedures to Defeat Gangs in U.S. Cities

    Science.gov (United States)

    2007-01-06

    organizations like the Iraqi- American Chamber of Commerce & Industry to help revitalize small businesses in Ramadi. Company commanders went throughout...collected over 500 assessments, which helped the Iraqi American Chamber of Commerce begin its grant operations… This is the same technique that we use

  10. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    OpenAIRE

    Barbosa, Jose Augusto; Rodrigues,Alexandre; Mota,Cleonice; Barbosa,M M; Simoes-e-Silva,Ana

    2011-01-01

    José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both dev...

  11. Mass spectrometer diagnostic technique in the study of stationary afterglow plasmas in helium, argon and krypton

    International Nuclear Information System (INIS)

    Langenwalter, M.

    1979-01-01

    Since some years the method of massspectrometric monitoring has become an important tool in the analysis of time resolved (or stationary) afterglow plasmas. The present thesis reports the construction and testing of a new fully bakeable UHV-stationary-afterglow-apparatus using a hollow cathode discharge as plasma source for the first time. The hollow cathode is moveable perpendicular to its axis relative to the sampling orifice (i.e. a very small hole at the centre of the plasma container's boundary), so that the radical distribution of the charged particle density can be studied. Several specific extraction conditions for ions from the plasma especially the sampling probe potential have been systematically investigated. Results are illustrated and discussed. The new apparatus has been tested by determining the ambipolar diffusion coefficient of the molecular ion He 2 + in a pure Helium-plasma in thermal equilibrium. The present result (Dsub(a2) = 603 +- 38 / P 0 cm 2 s -1 ) is in agreement with results reported by other workers. Finally an example for the radial behaviour of the Ar + -sampling current in an Argon-discharge for several different times in the afterglow period is given. The shown behaviour agrees relatively well with the theoretically predicted radial ion density distribution, i.e. the zero-order Ressel'function. (Author)

  12. Activities identification for activity-based cost/management applications of the diagnostics outpatient procedures.

    Science.gov (United States)

    Alrashdan, Abdalla; Momani, Amer; Ababneh, Tamador

    2012-01-01

    One of the most challenging problems facing healthcare providers is to determine the actual cost for their procedures, which is important for internal accounting and price justification to insurers. The objective of this paper is to find suitable categories to identify the diagnostic outpatient medical procedures and translate them from functional orientation to process orientation. A hierarchal task tree is developed based on a classification schema of procedural activities. Each procedure is seen as a process consisting of a number of activities. This makes a powerful foundation for activity-based cost/management implementation and provides enough information to discover the value-added and non-value-added activities that assist in process improvement and eventually may lead to cost reduction. Work measurement techniques are used to identify the standard time of each activity at the lowest level of the task tree. A real case study at a private hospital is presented to demonstrate the proposed methodology. © 2011 National Association for Healthcare Quality.

  13. The effect of sampling, diagnostic criteria and assessment procedures on the observed prevalence of DSM-III-R personality disorders among treated alcoholics.

    Science.gov (United States)

    Verheul, R; Hartgers, C; Van den Brink, W; Koeter, M W

    1998-03-01

    OBJECTIVE. In a recent review of empirical studies on the prevalence of DSM-III-R personality disorders among substance abusers, wide ranges of prevalence rates for overall Axis II, antisocial personality disorder (APD) and borderline personality disorder (BPD) were shown. Utilizing subsamples from within a single study population, the current report explores the effect of sampling, diagnostic criteria and assessment procedures on the observed prevalence of DSM-III-R personality disorders among treated alcoholics. Personality disorders were assessed with the Personality Diagnostic Questionnaire Revised (PDQR) at two times of measurement (Time 1 n = 459; Time 2 n = 90). In addition, APD was measured with the Composite International Diagnostic Interview (CIDI; n = 587). Finally, an unselected subgroup (n = 136) was interviewed with the International Personality Disorder Examination (IPDE). There were few differences between inpatients or outpatients or between males and females. Using the IPDE, the exclusion of substance-related pathology did not affect the prevalence estimate. However, the prevalence rates according to the PDQR varied greatly across age groups. In a representative subsample (n = 109), the prevalence rates also varied greatly across assessment methods (PDQR, 52% vs IPDE, 31%). The prevalence estimate of APD according to the CIDI was related to setting, gender, age group and the applied time-frame. These findings indicate the examined factors to be necessary qualifiers of prevalence estimates and, consequently, support the use of a multiple-criteria/multimethod assessment battery in research as well as in clinical work.

  14. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  15. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  16. Diagnostic imaging procedures during pregnancy: what are the fetal risks?

    International Nuclear Information System (INIS)

    Taylor, K.

    2008-01-01

    An important facet of health care is the counsel of patients seeking a better understanding of their medical treatment. One of the most challenging scenarios is the management of female patients exposed to ionizing radiation while pregnant. It requires careful consideration of both maternal benefit and fetal risk. Given the increased frequency of diagnostic examinations involving ionizing radiation, this situation has become commonplace. This paper reviews current literature discussing the risk associated with prenatal exposure to ionizing radiation. The fetal dose received during common radiological procedures is reported in order to emphasize that these doses do not exceed threshold levels for deterministic effects. The definitive cancer risk associated with radiation exposure in utero has yet to be established. This paper will also show that physicians who deal with pregnant women are generally uninformed or misinformed of the doses and risks associated with the exams that they prescribe. This lack of information could be leading to inappropriate advice and actions with respect to patient care. (author)

  17. Diagnostic imaging procedures during pregnancy: what are the fetal risks?

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K. [McMaster Univ., Hamilton, Ontario (Canada)

    2008-07-01

    An important facet of health care is the counsel of patients seeking a better understanding of their medical treatment. One of the most challenging scenarios is the management of female patients exposed to ionizing radiation while pregnant. It requires careful consideration of both maternal benefit and fetal risk. Given the increased frequency of diagnostic examinations involving ionizing radiation, this situation has become commonplace. This paper reviews current literature discussing the risk associated with prenatal exposure to ionizing radiation. The fetal dose received during common radiological procedures is reported in order to emphasize that these doses do not exceed threshold levels for deterministic effects. The definitive cancer risk associated with radiation exposure in utero has yet to be established. This paper will also show that physicians who deal with pregnant women are generally uninformed or misinformed of the doses and risks associated with the exams that they prescribe. This lack of information could be leading to inappropriate advice and actions with respect to patient care. (author)

  18. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery

    Directory of Open Access Journals (Sweden)

    Hideyuki Suenaga

    2016-01-01

    Conclusion: The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results.

  19. Some novel diagnostic techniques for plasma chemistry

    International Nuclear Information System (INIS)

    Kaufman, M.

    1976-01-01

    In order to probe the mechanisms of chemical transformations in electric discharges it is most useful to monitor concentrations of reactants, products and reactive intermediates as a function of discharge parameters. Mass spectrometry, a popular technique for observing intermediates in chemical reactions, meets with particular difficulty when applied to discharges, due to the presence of excited molecules as well as free radicals in such systems. Molecular beam analysis, a synthesis of mass spectrometry with molecular beam measurements of electric and magnetic moments and velocity distributions, is a technique developed in the laboratory which offers distinct advantages for the analysis of intermediates in electric discharges. In low pressure discharges, end-product analysis can be facilitated by sample compression. A chromatographic sampling system which employs compression in order to achieve sensitivity has been developed and evaluated. There is some question concerning the appropriate discharge parameters to be employed in correlating measured variations in concentrations. An investigation is being made of the use of discharge 'actinometers' as a means of measuring the intensity of electric discharges. In discharges the intensity (number and energy of the electrons) and the chemistry are strongly coupled. Thus, it is necessary that the actinometer be present in the reactor; it is not permissible to substitute vessels as is customary in photochemical investigations. Since the actinometer is to measure only the discharge intensity, it must not participate in any chemical reactions with molecules and intermediates in the discharge. Finally, the ratio of the rates of the primary interactions of the actinometer and reactant with the discharge must be independent of discharge parameters. (author)

  20. Multiservice Tactics, Techniques, and Procedures for Treatment of Chemical Agent Casualties and Conventional Military Chemical Injuries

    Science.gov (United States)

    2007-09-01

    breathing (too rapid and/or too deep) with a resultant decrease in carbon dioxide tension and respiratory alkalosis . hypopyon—Pus in the anterior...V-3 Effects of Sulfur Mustard on the Skin ................................................V-4 Effects of Sulfur Mustard on the Respiratory ...V-11 Effects of Arsenical Vesicants on the Respiratory Tract ..................V-12 Systemic Effects of Arsenical

  1. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  2. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P E; Sanchez, J

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  3. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  4. Update on procedure-related risks for prenatal diagnosis techniques

    DEFF Research Database (Denmark)

    Tabor, Ann; Alfirevic, Zarko

    2010-01-01

    Introduction: As a consequence of the introduction of effective screening methods, the number of invasive prenatal diagnostic procedures is steadily declining. The aim of this review is to summarize the risks related to these procedures. Material and Methods: Review of the literature. Results: Data...... from randomised controlled trials as well as from systematic reviews and a large national registry study are consistent with a procedure-related miscarriage rate of 0.5-1.0% for amniocentesis as well as for chorionic villus sampling (CVS). In single-center studies performance may be remarkably good due...... not be performed before 15 + 0 weeks' gestation. CVS on the other hand should not be performed before 10 weeks' gestation due to a possible increase in risk of limb reduction defects. Discussion: Experienced operators have a higher success rate and a lower complication rate. The decreasing number of prenatal...

  5. Procedure generation and verification

    International Nuclear Information System (INIS)

    Sheely, W.F.

    1986-01-01

    The Department of Energy has used Artificial Intelligence of ''AI'' concepts to develop two powerful new computer-based techniques to enhance safety in nuclear applications. The Procedure Generation System, and the Procedure Verification System, can be adapted to other commercial applications, such as a manufacturing plant. The Procedure Generation System can create a procedure to deal with the off-normal condition. The operator can then take correct actions on the system in minimal time. The Verification System evaluates the logic of the Procedure Generator's conclusions. This evaluation uses logic techniques totally independent of the Procedure Generator. The rapid, accurate generation and verification of corrective procedures can greatly reduce the human error, possible in a complex (stressful/high stress) situation

  6. Solitary fibrous tumor: A center's experience and an overview of the symptomatology, the diagnostic and therapeutic procedures of this rare tumor

    Directory of Open Access Journals (Sweden)

    Wolfgang Hohenforst-Schmidt

    2017-01-01

    Full Text Available Solitary Fibrous Tumor of the Pleura (SFTP is a rare tumor of the pleura. Worldwide about 800 patients diagnosed with this oncological entity have been described in the existing literature. We report our center's 13 year experience. During this time three patients suffering from this rare disease have been treated in our department. All patients were asymptomatic and their diagnosis was initially triggered by a random finding in a routine chest x-ray. The diagnosis was set preoperatively through a needle biopsy under computer tomography (CT guidance. The tumors were resected surgically though video-assisted thoracoscopic surgery (VATS or thoracotomy. Because of the lack of specific guidelines due to the rarity of the disease a long-term, systematic follow-up was recommended and performed. Parallel an overview of the diagnostic and therapeutic procedures of the rare tumor is made.

  7. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  8. The Awareness of Health Professionals in Diagnostic Techniques ...

    African Journals Online (AJOL)

    hanumantp

    clear that most reviewed articles used the same conventional methods in ... Knowledge about the possible correlation of occult blood with reasons other than ... diagnostic techniques used in the examination of intestinal parasites in Gaza Strip.

  9. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  10. "Heidelberg standard examination" and "Heidelberg standard procedures" - Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education.

    Science.gov (United States)

    Nikendei, C; Ganschow, P; Groener, J B; Huwendiek, S; Köchel, A; Köhl-Hackert, N; Pjontek, R; Rodrian, J; Scheibe, F; Stadler, A-K; Steiner, T; Stiepak, J; Tabatabai, J; Utz, A; Kadmon, M

    2016-01-01

    The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties.

  11. Laser-based techniques for combustion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, N.

    1997-04-01

    Two-photon-induced Degenerate Four-Wave Mixing, DFWM, was applied for the first time to the detection of CO, and NH{sub 3} molecules. Measurements were performed in a cell, and in atmospheric-pressure flames. In the cell measurements, the signal dependence on the pressure and on the laser beam intensity was studied. The possibility of simultaneous detection of NH{sub 3} and OH was investigated. Carbon monoxide and ammonia were also detected employing two-photon-induced Polarization Spectroscopy, PS. In the measurements performed in a cold gas flow, the signal strength dependence on the laser intensity, and on the polarization of the pump beam, was investigated. An approach to improve the spatial resolution of the Amplified Stimulated Emission, ASE, was developed. In this approach, two laser beams at different frequencies were crossed in the sample. If the sum of the frequencies of the two laser beams matches a two photon resonance of the investigated species, only the molecules in the intersection volume will be excited. NH{sub 3} molecules and C atoms were studied. The potential of using two-photon LIF for two-dimensional imaging of combustion species was investigated. Although LIF is species specific, several species can be detected simultaneously by utilizing spectral coincidences. Combining one- and two-photon process, OH, NO, and O were detected simultaneously, as well as OH, NO, and NH{sub 3}. Collisional quenching is the major source of uncertainty in quantitative applications of LIF. A technique for two-dimensional, absolute species concentration measurements, circumventing the problems associated with collisional quenching, was developed. By applying simple mathematics to the ratio of two LIF signals generated from two counterpropagating laser beams, the absolute species concentration could be obtained. 41 refs

  12. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel

  13. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel.

  14. A simple and cheap system to speed up and to control the tumescent technique procedure: the Tedde's system.

    Science.gov (United States)

    Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F

    2014-06-01

    We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.

  15. Radiation exposure to staff involved in diagnostic and therapeutic nuclear medicine procedures in some hospitals in Sudan

    International Nuclear Information System (INIS)

    Salih, Lamia Hamza Bashir

    2015-05-01

    Study was performed to evaluate radiation dose to staff involved in nuclear medicine procedures in some hospitals in Sudan. 15 radiation workers were studied in three hospitals. Radiation dose was measured using personal dose equivalent Hp (10), using calibrated electronic personal dosimeters (EPDs) worn on the chest and read at the end of the day. Staff doses were monitored in each hospital for a period of four weeks, The measured monthly Hp(10) values to staff ranged between 82.96-83.94μSv (to nurses), 38.81-53.97 μSv (to pharmacists), 16.87-70.21μSv (to technologists), 40.22-76.56μSv (to medical physicists). These mean monthly radiation doses were projected to the annual radiation doses received by the staff. The mean monthly radiation doses were projected to the annual radiation doses were found to be between ranges (185.57-923.34μSv/y). Results found showed that there was no dose that exceeded the limits of annual dose recommended for workers by International Commission on Radiology Protection (ICRP) (20 mSv/year). This study is expected to increase the awareness of staff about the radiation hazards and protection.(Author)

  16. Modeling and diagnostic techniques applicable to the analysis of pressure noise in pressurized water reactors and pressure-sensing systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Thie, J.A.

    1984-01-01

    Pressure noise data from a PWR are interpreted by means of a computer-implemented model. The model's parameters, namely hydraulic impedances and noise sources, are either calculated or deduced from fits to data. Its accuracy is encouraging and raises the possibility of diagnostic assistance for nuclear plant monitoring. A number of specific applications of pressure noise in the primary system of a PWR and in a pressure sensing system are suggested

  17. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    Science.gov (United States)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  18. Journal of Special Operations Medicine. Training Supplement to Fall 2008. Tactics, Techniques, and Procedures

    Science.gov (United States)

    2008-01-01

    suicide attacks may include the use of Sarin gas, Anthrax, or Polonium 210 . Incidental events such as the postal letter to Senator Daschle that...occurred in Washington, D.C. in October 2001 and the use of Polonium 210 against Alexander Litvinenko in November 2006 show the potential of future...the Food and Drug Administration (FDA) and proven to be effective in stopping life-threatening hemorrhage at the time of the publication of the

  19. Two-loop renormalization in the standard model, part II. Renormalization procedures and computational techniques

    Energy Technology Data Exchange (ETDEWEB)

    Actis, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Passarino, G. [Torino Univ. (Italy). Dipt. di Fisica Teorica; INFN, Sezione di Torino (Italy)

    2006-12-15

    In part I general aspects of the renormalization of a spontaneously broken gauge theory have been introduced. Here, in part II, two-loop renormalization is introduced and discussed within the context of the minimal Standard Model. Therefore, this paper deals with the transition between bare parameters and fields to renormalized ones. The full list of one- and two-loop counterterms is shown and it is proven that, by a suitable extension of the formalism already introduced at the one-loop level, two-point functions suffice in renormalizing the model. The problem of overlapping ultraviolet divergencies is analyzed and it is shown that all counterterms are local and of polynomial nature. The original program of 't Hooft and Veltman is at work. Finite parts are written in a way that allows for a fast and reliable numerical integration with all collinear logarithms extracted analytically. Finite renormalization, the transition between renormalized parameters and physical (pseudo-)observables, are discussed in part III where numerical results, e.g. for the complex poles of the unstable gauge bosons, are shown. An attempt is made to define the running of the electromagnetic coupling constant at the two-loop level. (orig.)

  20. Joint Tactics, Techniques, and Procedures for Joint Special Operations Task Force Operations

    Science.gov (United States)

    2001-12-19

    phase? Is a ration cycle proposed? •• Are fresh eggs, fresh fruits and vegetables, fresh meats, juices, milk , and canned soft-drink supplements to ration...measures designed to mislead the enemy by manipulation, distortion, or falsification of evidence to induce the enemy to react in a manner prejudicial to

  1. Whole of Government in the Economic Sector: Tactics, Techniques, and Procedures. Newsletter. Number 10-34

    Science.gov (United States)

    2010-03-01

    identified three forces influencing the Malaysian population: nationalism, religion and culture, and economic well-being.2 Of the three, he gave primacy...governance capacity, fiscal policy focused on increasing revenues, shifting toward indirect taxation , maintaining a flexible exchange rate, keeping

  2. Comparison of exercise perfusion and ventricular function imaging: an analysis of factors affecting the diagnostic accuracy of each technique

    International Nuclear Information System (INIS)

    Osbakken, M.D.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Exercise thallium-201 perfusion scans and gated equilibrium blood pool scans were performed in 120 catheterized patients with a chest pain syndrome. Eighty-six patients had coronary artery disease and 34 patients did not. The effects of gender, propranolol, exercise level, exercise ischemia, history of typical angina, history of previous myocardial infarction, electrocardiographic Q waves, number of diseases vessels and extent of coronary artery obstruction on diagnostic accuracy were evaluated. Thallium scans and anginal history were less sensitive for detecting coronary disease in women (men: thallium 79%; angina 77%; women: 54 and 46%, respectively; p less than 0.05). Exercise level did not significantly affect the diagnostic accuracy of either scan. Thallium and gated scans were both highly sensitive (95%) in detecting disease in 20 patients with a prior myocardial infarction, angina and a positive electrocardiogram. The sensitivity of the thallium scan significantly decreased as the number of diseased vessels decreased. Both thallium and gated scans were less frequently positive in patients with atypical angina or no Q waves, but were not significantly influenced by electrocardiographic ischemia. The sensitivity and specificity of both scans were low in 57 patients with the combination of atypical angina, no history of infarction and equivocal stress electrocardiogram thallium. When stress thallium scan evaluation included the electrocardiogram and thallium scan interpretation, the diagnostic accuracy was 81%. When all the information from gated scans (wall motion, ejection fraction, pulmonary blood volume) was combined for final gated scan evaluation, the diagnostic accuracy was 83%. When electrocardiographic data were added to all three gated scan variables, diagnostic accuracy was 77%

  3. Environmental sensing and combustion diagnostics

    International Nuclear Information System (INIS)

    Santoleri, J.J.

    1991-01-01

    This book contains proceedings of Environmental Sensing and Combustion Diagnostics. Topics covered include: Incineration Systems Applications, Permitting, And Monitoring Overview; Infrared Techniques Applied to Incineration Systems; Continuous Emission Monitors; Analyzers and Sensors for Process Control And Environmental Monitoring

  4. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  5. Imaging of the lumbosacral plexus. Diagnostics and treatment planning with high-resolution procedures; Bildgebung des Plexus lumbosacralis. Diagnostik und Therapieplanung mithilfe hochaufgeloester Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Jengojan, S.; Schellen, C.; Bodner, G.; Kasprian, G. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2017-03-15

    Technical advances in magnetic resonance (MR) and ultrasound-based neurography nowadays facilitate the radiological assessment of the lumbosacral plexus. Anatomy and imaging of the lumbosacral plexus and diagnostics of the most common pathologies. Description of the clinically feasible combination of magnetic resonance imaging (MRI) and ultrasound diagnostics, case-based illustration of imaging techniques and individual advantages of MRI and ultrasound-based diagnostics for various pathologies of the lumbosacral plexus and its peripheral nerves. High-resolution ultrasound-based neurography (HRUS) is particularly valuable for the assessment of superficial structures of the lumbosacral plexus. Depending on the examiner's experience, anatomical variations of the sciatic nerve (e. g. relevant in piriformis syndrome) as well as more subtle variations, for example as seen in neuritis, can be sonographically depicted and assessed. The use of MRI enables the diagnostic evaluation of more deeply located nerve structures, such as the pudendal and the femoral nerves. Modern MRI techniques, such as peripheral nerve tractography allow three-dimensional depiction of the spatial relationship between nerves and local tumors or traumatic alterations. This can be beneficial for further therapy planning. The anatomy and pathology of the lumbosacral plexus can be reliably imaged by the meaningful combination of MRI and ultrasound-based high resolution neurography. (orig.) [German] Durch technische Fortschritte im Bereich der magnetresonanz- (MR-) und ultraschallbasierten Neurographie ist der Plexus lumbosacralis heute der radiologischen Abklaerung zugaenglich. Anatomie und Bildgebung des Plexus lumbosacralis, Abklaerung der haeufigsten Pathologien. Erlaeuterung der klinisch sinnvollen Kombination von MR- und Ultraschalldiagnostik, Darstellung der Untersuchungstechniken und der jeweiligen Vorteile von MRT und Ultraschall anhand fallbasierter Praesentation unterschiedlicher

  6. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  7. Rak piersi w ciąży - odmienności procesu diagnostyki i leczenia = Breast cancer during pregnancy - differences in diagnostic and treatment procedures

    Directory of Open Access Journals (Sweden)

    Magdalena Sowa

    2016-09-01

    - differences in diagnostic and treatment procedures Abstract Introduction: Breast cancer during pregnancy is relatively rare. There has been an increasing trend for young women to delay childbearing for the last ten years. Presently the average age of first-time mothers is 30. Age is one of the factors increasing the risk of breast cancer. The defined clinical situation will appear more often considering the fact that women delay their motherhood where as the average age of breast cancer decreases. Objective: The purpose of this article is to present different diagnostic and treatment procedures of breast cancer diagnosed during pregnancy. Main text: The analysis of epidemiological data points the fact breast cancer is the most often appearing one in pregnant women. The fact that physiological changes in females during pregnancy first weeks may mask cancer is particularly dangerous and may essentially delay diagnostic procedures. Cancer diagnosed during pregnancy is always a traumatic and stressful situation for a woman and her family that is why its diagnostic and treatment procedures are considerably individualized whereas the maximum terapeutical effect with the protection of an unbornchild is the priority of activities. Summary: Therapeutic decisions are made after a review of a health condition of a patient, the extent of spread of cancer, gestational age and demands of the patient and her family. In the article, undertaking a literature review, alternative breast cancer diagnostic and treatment procedures during pregnancy were discussed in details.   Key words: brest cancer, pregnancy, diagnostics procedures, treatment

  8. Recent developments in diagnostic imaging techniques and management for acute pulmonary embolism. Multicenter registry by the Japanese Society of Pulmonary Embolism Research

    International Nuclear Information System (INIS)

    Sakuma, Masahito; Okada, Osamu; Nakamura, Mashio

    2003-01-01

    There are many reports on the diagnosis and management of acute pulmonary embolism (APE), but there have been no investigations concerning the actual conditions in which recent developments in diagnostic imaging techniques and therapies have been applied in clinical practice. The present study was designed to investigate the changes in diagnostic imaging techniques and therapies for APE. Three hundred and nine APE patients diagnosed during January 1994-October 1997 (Group 1) were compared with 257 APE patients diagnosed during November 1997-October 2000 (Group 2) in terms of the diagnostic imaging techniques and therapies for APE. Compared with Group 1, pulmonary angiography and contrast-enhanced computed tomography were more frequently performed for diagnosis in Group 2 [45.3% vs 56.8% (p=0.0069) and 13.9% vs 57.6% (p<0.0001), respectively]. Heparin and vena cava filter were used more often in Group 2 [74.4% vs 82.1% (p=0.033) and 18.4% vs 33.9% (p<0.0001), respectively]. The frequency of thrombolytic therapy was unchanged between the two groups. Warfarin use in discharged patients increased from 71.9% to 83.8% (p=0.0022). However, the examination rates for deep vein thrombosis (DVT) were low (60.8% in Group 1 and 65.4% in Group 2, p=0.29) and unchanged using any imaging techniques. The diagnostic imaging techniques for APE increased in variety and the management has improved, while the diagnosis for DVT remains unchanged. (author)

  9. Use of RT-PCR and elisa techniques for the diagnostic of infectious bronchitis virus in broilers at slaughter

    Directory of Open Access Journals (Sweden)

    Davi de Oliveira Almeida

    2015-03-01

    Full Text Available ABSTRACT. Almeida D.O., Tortely R., Nascimento E.R., Khan M., Pereira V.L.A & Babapoor S. [Use of RT-PCR and elisa techniques for the diagnostic of infectious bronchitis virus in broilers at slaughter.] Uso das técnicas de RT-PCR e elisa no diagnóstico da bronquite infecciosa em frangos de corte ao abate. Revista Brasileira de Medicina Veterinária, 37(1:55-59, 2015. Departamento de Saúde Coletiva Veterinária e Saúde Pública, Universidade Federal Fluminense, Rua Vital Brazil Filho, 64, Santa Rosa, Niterói, RJ 24230-340, Brasil. E-mail: elmiro@vm.uff.br Avian infectious bronchitis (IB is a viral, acute and highly contagious disease caused by infectious bronchitis virus (IBV. The disease affects broilers improvement and performance causing major economic losses in the world poultry industry. Generally, IBV infections can be diagnosed by detection of IBV itself or the specific antibody response. This study aimed to detect IBV in broilers under Sanitary Inspection by RT-PCR and ELISA, comparing the results and relating them with the average weight of the flock. Samples were collected from 40 vaccinated broiler flocks under Sanitary Inspection at slaughter. Ten birds from every flock were randomly selected and blood samples were collected for ELISA as well three birds had their trachea and caecal tonsils collected for RT- -PCR test. From 40 flocks, 30 were IBV positive by ELISA and 26 by RT-PCR, in which 15 were detected simultaneously in trachea and caecal tonsil and 5 in each sample. There was no agreement between ELISA and RT-PCR results regarding IBV diagnosis as well positivity in both tests was not statistically significant with the average weight of the flock. There was an improvement on IBV diagnosis when caecal tonsils and tracheas were used instead of just one of them. Considering the only vaccine serotype allowed by Brazilian government is the Mass serotype and its persistence in broilers would only be detected up to 28 days

  10. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  11. Diagnostic radiology of pet and wild birds: a review I. Radiographic techniques and radiographs of healthy birds

    International Nuclear Information System (INIS)

    Beregi, A.; Molnar, V.; Felkai, F.; Biro, F.; Szentgali, Zs.

    1999-01-01

    The first part of the present review summaries the basic technical conditions of radiological examinations, analyses the radiographic features of healthy birds, and describes the procedure and radiological indications of contrast radiography. (This paper can be seen on the Internet at: http://www.akkrt.hu)

  12. A retrospective study of relevant diagnostic procedures in vulvodynia

    DEFF Research Database (Denmark)

    Petersen, Christina Damsted; Kristensen, Ellids; Lundvall, Lene

    2009-01-01

    OBJECTIVE: To identify objective clinical signs of vulvodynia and determine specific diagnostic tests for vulvodynia in women referred to a vulvar outpatient clinic for vulval complaints. STUDY DESIGN: A retrospective study was performed of the medical records of 201 consecutive Danish patients s...

  13. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  14. Comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures: The boomerang™ wire vascular access management trial II.

    Science.gov (United States)

    Goswami, Nilesh J; Smalling, Ronnie G; Sinha, Shantanu; Gammon, Roger S; Ramaiah, Venkatesh G

    2016-01-01

    To evaluate the use of the Boomerang™ Wire as an adjunct to manual compression (MC) in patients requiring diagnostic (Dx) or interventional (Ix) percutaneous procedures. MC remains the standard of care for closure of femoral artery access sites. Adjunctive use of a device to facilitate closure, reduce time to hemostasis (TTH) and ambulation (TTA) without increasing complication rates could reduce costs and hospital resource demands. The Boomerang™ Trial was a prospective, multicenter, randomized, controlled trial comparing use of the Boomerang™ wire, (Cardiva Medical, Sunnyvale, CA) in conjunction with MC versus MC alone to achieve hemostasis in Dx and Ix patients undergoing percutaneous procedures requiring femoral artery access. Endpoints included TTH, TTA, major, and minor access-site related complications. Subjects were randomized 3:1, Boomerang versus MC. No minor or major device-related adverse events were reported. Nondevice related complication rates were 3 (0.9%) in the Boomerang arm (n = 327) and 1 (0.8%) in MC arm (n = 123). Mean TTH for Boomerang vs. MC was 11.2 ± 4.3 vs. 23.2 ± 11 min for Dx (P Boomerang vs. MC was 3.3 ± 3.0 vs. 4.5 ± 2.0 hr (P Boomerang™ use, in conjunction with MC, was associated with low rates of complications and demonstrated that Boomerang™ as an adjunct to MC can significantly decrease TTH and TTA after both Dx and Ix procedures. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  15. A Computer-Based, Interactive Videodisc Job Aid and Expert System for Electron Beam Lithography Integration and Diagnostic Procedures.

    Science.gov (United States)

    Stevenson, Kimberly

    This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…

  16. Value of noninvasive diagnostic procedures in cardiology: typical findings in hypertrophic obstructive cardiomyopathy

    International Nuclear Information System (INIS)

    Riebeling, V.; Bubenheimer, P.

    1984-01-01

    Routine chest X-ray often yields poor information for diagnosis of heart disease. The diagnostic value of invasive procedures in cardiology is generally accepted. The patient's as well as the physician's risk of the examination, however, has to be considered. A high number of heart diseases, e.g. hypertrophic obstructive cardiomyopathy (HOCM) is mainly detected by noninvasive procedures such as auscultation, electrocardiography, phonomechanocardiography, echocardiography, physical manoeuvres, and pharmacological provocation tests. Typical findings in hypertrophic obstructive cardiomyopathy are demonstrated. (orig.) [de

  17. Taenia solium porcine cysticercosis in Madagascar: Comparison of immuno-diagnostic techniques and estimation of the prevalence in pork carcasses traded in Antananarivo city.

    Science.gov (United States)

    Porphyre, V; Betson, M; Rabezanahary, H; Mboussou, Y; Zafindraibe, N J; Rasamoelina-Andriamanivo, H; Costard, S; Pfeiffer, D U; Michault, A

    2016-03-30

    Taenia solium cysticercosis was reported in official veterinary and medical statistics to be highly prevalent in pigs and humans in Madagascar, but few estimates are available for pigs. This study aimed to estimate the seroprevalence of porcine cysticercosis among pigs slaughtered in Antananarivo abattoirs. Firstly, the diagnostic performance of two antigen-ELISA techniques (B158B60 Ag-ELISA and HP10 Ag-ELISA) and an immunoblotting method were compared with meat inspection procedures on a sample of pigs suspected to be infected with (group 1; n=250) or free of (group 2; n=250) T. solium based on direct veterinary inspection in Madagascar. Sensitivity and specificity of the antigen ELISAs were then estimated using a Bayesian approach for detection of porcine cysticercosis in the absence of a gold standard. Then, a third set of pig sera (group 3, n=250) was randomly collected in Antananarivo slaughterhouses and tested to estimate the overall prevalence of T. solium contamination in pork meat traded in Antananarivo. The antigen ELISAs showed a high sensitivity (>84%), but the B158B60 Ag-ELISA appeared to be more specific than the HP10 Ag-ELISA (model 1: 95% vs 74%; model 2: 87% vs 71%). The overall prevalence of porcine cysticercosis in Antananarivo slaughterhouses was estimated at 2.3% (95% credibility interval [95%CrI]: 0.09-9.1%) to 2.6% (95%CrI: 0.1-10.3%) depending on the model and priors used. Since the sample used in this study is not representative of the national pig population, village-based surveys and longitudinal monitoring at slaughter are needed to better estimate the overall prevalence, geographical patterns and main risk factors for T. solium contamination, in order to improve control policies. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A Methods and procedures to apply probabilistic safety Assessment (PSA) techniques to the cobalt-therapy process. Cuban experience

    International Nuclear Information System (INIS)

    Vilaragut Llanes, J.J.; Ferro Fernandez, R.; Lozano Lima, B; De la Fuente Puch, A.; Dumenigo Gonzalez, C.; Troncoso Fleitas, M.; Perez Reyes, Y.

    2003-01-01

    This paper presents the results of the Probabilistic Safety Analysis (PSA) to the Cobalt Therapy Process, which was performed as part of the International Atomic Energy Agency's Coordinated Research Project (CRP) to Investigate Appropriate Methods and Procedures to Apply Probabilistic Safety Assessment (PSA) Techniques to Large Radiation Sources. The primary methodological tools used in the analysis were Failure Modes and Effects Analysis (FMEA), Event Trees and Fault Trees. These tools were used to evaluate occupational, public and medical exposures during cobalt therapy treatment. The emphasis of the study was on the radiological protection of patients. During the course of the PSA, several findings were analysed concerning the cobalt treatment process. In relation with the Undesired Events Probabilities, the lowest exposures probabilities correspond to the public exposures during the treatment process (Z21); around 10-10 per year, being the workers exposures (Z11); around 10-4 per year. Regarding to the patient, the Z33 probabilities prevail (not desired dose to normal tissue) and Z34 (not irradiated portion to target volume). Patient accidental exposures are also classified in terms of the extent to which the error is likely to affect individual treatments, individual patients, or all the patients treated on a specific unit. Sensitivity analyses were realised to determine the influence of certain tasks or critical stages on the results. As a conclusion the study establishes that the PSA techniques may effectively and reasonably determine the risk associated to the cobalt-therapy treatment process, though there are some weaknesses in its methodological application for this kind of study requiring further research. These weaknesses are due to the fact that the traditional PSA has been mainly applied to complex hardware systems designed to operate with a high automation level, whilst the cobalt therapy treatment is a relatively simple hardware system with a

  19. FEL components and diagnostics

    International Nuclear Information System (INIS)

    Carr, R.

    1997-01-01

    FEL hardware includes undulators, alignment systems, electron beam diagnostics, and mechanical and vacuum systems. While most FEL close-quote s employ conventional undulators, there is some interest in novel types, particularly where conventional designs cannot be used, as at very short periods and high fields. For these areas, superconducting technology is indicated. The most serious issue facing long FEL undulators is that of alignment; mechanical techniques may not be accurate enough, and beam-based strategies must be considered. To maintain alignment and control the electron trajectory, beam position monitors with micron precision are required. Beam size monitors are also required to assure control of emittance. The talks given in the working group sessions touch on undulators, alignment, and electron beam diagnostics, and they are summarized here. copyright 1997 American Institute of Physics

  20. Efficacy of clinical diagnostic procedures utilized in nuclear medicine. Nine month progress report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    This study is designed to determine the efficacy of nuclear medicine procedures in clinical practice. Several methods of determining efficacy will be evaluated to determine those most suitable. Nuclear medicine methods will be confined to the study of lung diseases by pulmonary perfusion and ventilation. In addition to evaluating the above methods data will be obtained to determine the sensitivity, specificity, predictive value and efficiency of the test under consideration. These values, corrected for prevalence of the disease processes under consideration will then be compared to the values obtained by the MACRO and MICRO methods and will help to bound the clinical reliability of the diagnostic method depending on the degree to which the several methods trend together. Depending on the practicality of these two methods, in addition to the determination of efficacy, cost effectiveness factors and benefit-risk estimates which are used to apply to radiation effects will be determined for nuclear medicine studies of the brain, bone, heart, liver and thyroid subsequently. The measurement techniques will then be utilized to establish guidelines for the most useful applications of the given procedure so that clinicians will be able to obtain a pretest estimate of the utility of the nuclear medicine test.

  1. Applications of Molecular Diagnostic Techniques for Infectious ...

    African Journals Online (AJOL)

    That outcome, if accurate, would help the clinician in disease management, or the epidemiologist in identifying trends of diseases or the administrator in policy and decision making. Traditionally, infectious disease diagnosis involves identifying the causative agents of infectious diseases through the direct examination, ...

  2. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  3. Value of five noninvasive diagnostic techniques and their combinations in diagnosis of liver fibrosis in patients with chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    ZHANG Xu

    2016-10-01

    Full Text Available Objective To investigate the correlation of aspartate aminotransferase to platelet ratio index (APRI, FIB-4, Forns index, S index, and FibroScan with the degree of liver fibrosis, the diagnostic value of these techniques used alone or in combination, and the clinical value of these noninvasive techniques in the assessment of the degree of liver fibrosis in patients with chronic hepatitis B (CHB. Methods A retrospective analysis was performed for the clinical data of 91 patients with pathologically confirmed CHB who visited General Hospital of Ningxia Medical University and underwent liver biopsy from January 2009 to April 2015. According to the Scheuer pathological stage and liver fibrosis stage (S, the patients were divided into non-liver fibrosis group (a liver fibrosis stage of S0, 32 patients, mild liver fibrosis group (a liver fibrosis stage of <S2, 30 patients, and marked liver fibrosis group (a liver fibrosis stage of ≥S2, 29 patients. The APRI, FIB-4, Forns index, and S index were calculated, and liver stiffness was measured by FibroScan. An analysis of variance was used for the comparison of normally distributed continuous data between three groups, and the Dunnett t-test was used for further comparison between any two groups. The Spearman correlation analysis was also performed. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC were used to evaluate the value of these noninvasive techniques in the diagnosis of liver fibrosis. Results There were significant differences in age, albumin, aspartate aminotransferase, alanine aminotransferase, and platelet count between the three groups (F=3.552, 4.035, 4.374, and 5.992, all P<0.05, and there were significant differences in these parameters between the non-liver fibrosis group and the mild and marked liver fibrosis groups (P<0.05. There were significant differences in APRI, FIB-4, Forns index, S index, and FibroScan between the three groups (F

  4. Diagnostics and structure

    International Nuclear Information System (INIS)

    Vial, J.C.

    1986-01-01

    The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation

  5. Radiation dose to the pediatric population of Slovak Republic from diagnostic nuclear medicine procedures

    International Nuclear Information System (INIS)

    Ftacnikova, S.; Fueriova, A.

    1996-01-01

    The increased number of in vitro diagnostic nuclear medicine examinations has created the need for more precise determination of radiation dose to the population, specially to the children. A questionnaire survey has been performed on all nuclear medicine facilities in Slovak Republic through 1982 to 1994 with a special attention to pediatric patients in 1994. The information obtained was about the age distribution, number of different types of examinations, radiopharmaceuticals used and the value of mean administered radioactivity per exam. These data were used to evaluate the mean effective dose per exam and per capita, the collective effective dose for special type of examinations, for different radiopharmaceuticals and for radionuclides used in diagnostic procedures. In calculations we used the best available biokinetic models of the distribution of radiopharmaceuticals in organs as a function of age. The results show that the Slovak Republic appeared favorable in comparison to other countries in the judicious use of diagnostic nuclear medicine procedures performed on pediatric population. (author)

  6. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  7. Analysis of diagnostic calorimeter data by the transfer function technique

    Energy Technology Data Exchange (ETDEWEB)

    Delogu, R. S., E-mail: rita.delogu@igi.cnr.it; Pimazzoni, A.; Serianni, G. [Consorzio RFX, Corso Stati Uniti, 35127 Padova (Italy); Poggi, C.; Rossi, G. [Università degli Studi di Padova, Via 8 Febbraio 1848, 35122 Padova (Italy)

    2016-02-15

    This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

  8. Diagnostics of machine parts by means of reverse engineering procedures

    Directory of Open Access Journals (Sweden)

    Jacek Rysinski

    2015-05-01

    Full Text Available In this article, an application of a three-dimensional scanner for building a special diagnostic stand is described. An experimental method of detection of material defects is discussed. The considered defects are connected with cooperation of particular surfaces of machine parts. In the discussed experiments, particularly the dimensions of pitting holes can be evaluated. Availability of laboratory facilities required that the investigations were performed using geared wheels. The three-dimensional model which represents a degenerated surface, obtained based upon the diagnostic measurements, was compared with the pattern of an undamaged surface. The latter was generated by means of our pre-processor. The pre-processor enables generation of files which are compatible with the majority of the computer-aided design system formats. Therefore, the analyses were performed by means of commercial system inventor and computer-aided three-dimensional interactive application.

  9. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  10. A PILOT PROJECT FOR THE DEVELOPMENT OF EDUCATIONAL RESEARCH TECHNIQUES AND PROCEDURES SUITABLE FOR THE MEASUREMENT OF INSTITUTIONAL STABILITY AND CHANGE.

    Science.gov (United States)

    TURNEY, DAVID T.

    THE PROBLEM INVESTIGATED IN THIS STUDY INVOLVED THE DEVELOPMENT OF TECHNIQUES AND PROCEDURES THAT COULD YIELD MEASURES OF INSTITUTIONAL STABILITY AND CHANGE ALONG A TIME CONTINUUM. THE STUDY FOCUSED ON THE PUPILS AND TEACHERS IN THE UNIVERSITY SCHOOL OF KENT STATE UNIVERSITY (658 PUPILS IN KINDERGARTEN CLASSES THROUGH GRADE 12 AND 29 INSTRUCTORS).…

  11. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    Science.gov (United States)

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. MDCT evaluation of pulmonary embolism in children and young adults following a lateral tunnel Fontan procedure: optimizing contrast-enhancement techniques

    International Nuclear Information System (INIS)

    Prabhu, Sanjay P.; Mahmood, Soran; Sena, Laureen; Lee, Edward Y.

    2009-01-01

    Pulmonary embolism (PE) is a life-threatening thromboembolic complication in patients who have undergone a Fontan procedure for augmenting pulmonary blood flow in the setting of single-ventricle physiology. In patients following a Fontan procedure, lack of proper contrast agent mixing in the right atrium and sluggish, low-velocity blood flow within the Fontan circulation often results in suboptimal contrast enhancement within the pulmonary artery for evaluating PE. Unfortunately, there is a paucity of information describing the optimal contrast-enhancement technique with multidetector CT (MDCT) for evaluating PE in children and young adults following a Fontan procedure. We illustrate the MDCT imaging findings of suboptimal contrast enhancement within the pulmonary artery, which can be mistaken for PE, in patients following a lateral Fontan procedure, and we discuss MDCT techniques to optimize contrast enhancement within the pulmonary artery in these patients for evaluating PE. The MDCT imaging findings in pediatric and young adult patients following a lateral Fontan procedure and with clinically suspected PE are illustrated. We describe intravenous contrast agent injection techniques that can be used to optimize the contrast enhancement in the pulmonary artery in patients following a lateral Fontan procedure. The use of a suboptimal contrast-enhancement technique led to initial misdiagnosis and incomplete evaluation of PE in the three patients following a lateral Fontan procedure. Imaging in two patients showed that optimal evaluation of thrombosis in the Fontan pathway and PE in the pulmonary arteries can be successfully achieved with simultaneous upper- and lower-limb injections of contrast agent. This series demonstrates that suboptimal contrast enhancement can result in misdiagnosis or incomplete evaluation of PE in children and young adults following a lateral Fontan procedure. Careful attention to optimizing contrast enhancement during MDCT examination for

  13. [A diagnostic algorithm and treatment procedure in disordered vital functions in newborns admitted to a resuscitation ward].

    Science.gov (United States)

    Ostreĭkov, I F; Podkopaev, V N; Moiseev, D B; Karpysheva, E V; Markova, L A; Sizov, S V

    1997-01-01

    Total mortality decreased by 2.5 times in the wards for intensive care of the newborns in the Tushino Pediatric Hospital in 1996 and is now 7.6%. Such results are due to a complex of measures, one such measure being the development and introduction of an algorithm for the diagnosis and treatment of newborns hospitalized in intensive care wards. The algorithm facilitates the work of the staff, helps earlier diagnose a disease, and, hence, carry out timely scientifically based therapy.

  14. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  15. Schistosomiasis mansoni in Bananal (State of São Paulo, Brazil: I. Efficiency of diagnostic and treatment procedures

    Directory of Open Access Journals (Sweden)

    Horacio Manuel Santana Teles

    2002-10-01

    Full Text Available Bananal is an important focus of Schistosoma mansoni in the State of São Paulo. Accordingly, programmed active search for human cases, annual coproscopic surveys and treatment of infected cases were started in 1998, aiming at producing a sharp prevalence rate drop by the year 2000. S. mansoni eggs were searched for in two Kato-Katz slides per patient. Cases were followed up according to the routine of the local Family Health Program. In 1998, 130 samples out of 3,860 showed S. mansoni eggs; in 1999, 105 out of 3,550, and in 2000, 64 out of 3,528. Prevalence rates were 3.4%, 2.9%, and 1.8%, and average egg-counts 59, 64, and 79 eggs per gram of feces respectively. Prevalence rates decreased steadily after treatment, but persistently positive cases showed no significant decrease in parasite burdens. Egg count variation depended on sex and age bracket. Persistent residual cases admittedly preclude the eradication of this infection by only searching for and treating carriers. In addition, resistance to therapy and low sensitivity of fecal examinations, can not be ignored. Moderate to heavy worm burdens, frequently associated with hepatomegaly elsewhere, produced no serious cases in Bananal.

  16. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Schandorf, C.; Tetteh, G.K

    1998-07-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  17. Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in Ghana

    International Nuclear Information System (INIS)

    Schandorf, C.; Tetteh, G.K.

    1998-01-01

    The levels of dose and dose distributions for adult patients undergoing five selected common types of X ray examination in Ghana were determined using thermoluminescence dosemeters (TLD) attached to the skin where the beam enters the patient. To assess the performance of each X ray room surveyed, the mean of the entrance surface dose for patients whose statistics were close to a standard patient (70 kg weight and 20 cm AP trunk thickness) were compared to the Commission of the European Communities guideline values for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP examinations. The third quartiles dose values were 1.3 mGy, 14.5 mGy, 12.0 mGy and 7.9 mGy for chest PA, lumbar spine AP, pelvis/abdomen AP and skull AP respectively. Analysis of the data show that 86%, 58%, 37.5% and 50% of radiographic rooms delivered a mean dose greater than the CEC guideline values for chest PA, lumbar spine AP, pelvis/abdomen and skull AP respectively. This suggests that radiographic departments should undertake a review of their radiographic practice in order to bring their doses to optimum levels. (author)

  18. Advantages of the first-derivative probe technique over the three- and four-parameter probe techniques in fusion plasmas diagnostics

    Czech Academy of Sciences Publication Activity Database

    Hasan, E.; Dimitrova, Miglena; Popov, T.; Ivanova, P.; Dejarnac, Renaud; Stöckel, Jan; Pánek, Radomír

    2018-01-01

    Roč. 13, č. 4 (2018), č. článku P04005. ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LM2015045 Institutional support: RVO:61389021 Keywords : Plasma potential * electron temperature * bi-Maxwellian EEDF * Divertor Langmuir probes * three- and four-parameter probe techniques * first-derivative probe technique Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/04/P04005/meta

  19. Disease caused by non-tuberculous mycobacteria: diagnostic procedures and treatment evaluation in the North of Buenos Aires Province

    Directory of Open Access Journals (Sweden)

    Belén Imperiale

    2012-03-01

    Full Text Available Non-tuberculous mycobacteria (NTM have emerged as pathogens frequently associated to HIV co-infection. The aims of this study were to describe the clinical importance of NTM in patients from the North of Buenos Aires Province and the drug-susceptibility patterns in relation with the therapy used. A total of 23,624 clinical specimens were investigated during the period 2004-2010. Ziehl-Neelsen stain and cultures were used for diagnosis. Molecular and biochemical tests were performed to identify the mycobacteria. TB and mycobacterioses cases were 2 118 and 108 respectively. Sixteen NTM species were found: Mycobacterium avium and Mycobacterium intracellulare as the main causative agents. Infections produced by more than one species at the same time were confirmed (4 cases. Macrolides and fluoroquinolones were the most active in vitro drugs. Treatment evaluation showed that 68.0 % of the cases completed the therapy, 20 % died; and 12 % were relapses. The cases in which the treatment outcome was evaluated received an individual tailor-made therapeutic scheme including those drugs showing in vitro activity and presumed in vivo usefulness. More than a quarter of the patients had HIV co-infection and the majority of the deaths were associated with this co-infection.Enfermedad causada por micobacterias no tuberculosas: diagnóstico y evaluación del tratamiento en el norte del Gran Buenos Aires. Las micobacterias no tuberculosas (MNT emergieron como patógenos frecuentemente asociados a la co-infección con el HIV. EL objetivo del estudio fue describir la importancia clínica de las MNT en pacientes de la región norte de la provincia de Buenos Aires y los patrones de drogo-sensibilidad en relación con la terapia empleada. Se investigó un total de 23.624 especímenes clínicos durante, el período 2004-2010. La tinción de Ziehl-Neelsen y los cultivos se utilizaron para diagnóstico. Las micobacterias fueron identificadas mediante pruebas bioqu

  20. Galactography: the diagnostic procedure of choice for nipple discharge

    International Nuclear Information System (INIS)

    Tabar, L.; Dean, P.B.; Pentek, Z.

    1983-01-01

    Galactogrpahy was performed in 204 women with a nipple discharge and the secretion confirmed histopathologically. All 116 intraductal tumors (papilloma, papillomatosis, carcinoma), which were associated with a serous or bloody discharge, were detected preoperatively. A palpable mass had little diagnostic significance, and exfoliative cytology was positive in only 11% (2/18) of the patients with carcinoma. The authors recommend that all patients with a spontaneous bloody or serous discharge from a single lactiferous orifice undergo galactography in addition to physical, cytological, and mammographic examination. Intraductal injection of methylene blue dye will demonstrate the affected duct system to the surgeon and can often make surgery less radical or even unnecessary

  1. Modern diagnostic procedures in disorders of the thyroid gland

    International Nuclear Information System (INIS)

    Grebe, S.F.; Mueller, H.

    1984-01-01

    For functional diagnostics the FT4 index is calculated from the T4 and T3U values. Hyperthyroidism is suggested or borderline values an found, the T3 test is carried out. An index of free iodine hormones (IFIH) can be calculated. (IFIH=T4+30 x T3(μg/100 ml)/ST3U). Hypothyroidism and borderline cases require TSH evaluation or even a TRH test. T4 and T3 autoantibodies can cause high or low values in spite of euthyroidism or hypothyroidism. Difference in FT4 values are found if the kits used were not made by the same manufacturer. These values help to determine hyperthyroidism in pregnancy. The FT3 value is better than the TT3 value in determining T3 hyperthyroidism in borderline cases. Autonomy can be guaranteed by the 123 I short test or the 20-min 99 m Tc uptake test before and after administration of T4. Location diagnostics by scintigraphy after administration of 99 m Tc or radioiodine determine localization, size, shape, and distribution of functioning thyroid tissue and metastases by iodine accumulation. This is imaging of biochemical processes. By ultrasonography, a physical method, cysts, disintegration cysts or parenchymal nodes can be recognized. X-ray films of the trachea can determine stenosis caused by a struma. In addition to the exact proof of an intrathoracal struma (front and back mediastine), a retrotracheal or retroesophageal thyroid gland can be seen in CT. RIA determination of the tumor markers calcitonin and TG support the diagnostics of medullar and follicular or papillary thyroid carcinoma. (orig.) [de

  2. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear: A Systematic Review With Meta-analysis.

    Science.gov (United States)

    Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per

    2017-09-01

    Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US

  3. Image based measurement techniques for aircraft propeller flow diagnostics : Propeller slipstream investigations at high-lift conditions and thrust reverse

    NARCIS (Netherlands)

    Roosenboom, E.W.M.

    2011-01-01

    The aim of the thesis is to measure the propeller slipstream properties (velocity and vorticity) and to assess the unsteady and instantaneous behavior of the propeller flow field at high disk loadings, zero thrust and thrust reverse using the image based measurement techniques. Along with its

  4. Diagnostic radiation and pregnancy

    International Nuclear Information System (INIS)

    Collins, L.; Fitzgerald, P.

    1983-01-01

    Accidental irradiation of the embryo or fetus in the first trimester is a problem which will occasionally occur. The value of a proper estimation of the radiation dose is emphasised. Very rarely does a single diagnostic procedure result in a uterine dose as high as 50 mGy. An accidental irradiation should rarely be cause for termination of a pregnancy

  5. Procedural learning and dyslexia.

    Science.gov (United States)

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. 2010 John Wiley & Sons, Ltd.

  6. Digital image intensifier radiography: A new diagnostic procedure in traumatology?

    International Nuclear Information System (INIS)

    Schmidt, C.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1990-01-01

    Digital image intensifier radiography visualises all traumatological changes of clinical relevance and can therefore be used in traumatology. However, the quality of conventional radiographs cannot be attained as yet. Radiation exposure is markedly reduced, and radiographs are obtained directly after exposure, so that this is an extremely rapid radiographic procedure. Images can be quickly transmitted by video cable to the relevant departments and working places. (orig.) [de

  7. The urgent need for universally applicable simple screening procedures and diagnostic criteria for gestational diabetes mellitus – lessons from projects funded by the World Diabetes Foundation

    Directory of Open Access Journals (Sweden)

    Maximilian de Courten

    2012-07-01

    Full Text Available Background: To address the risks of adverse pregnancy outcomes and future type 2 diabetes associated with gestational diabetes mellitus (GDM, its early detection and timely treatment is essential. In the absence of an international consensus, multiple different guidelines on screening and diagnosis of GDM have existed for a long time. This may be changing with the publication of the recommendations by the International Association of Diabetes and Pregnancy Study Groups. However, none of these guidelines take into account evidence from or ground realities of resource-poor settings. Objective: This study aimed to investigate whether GDM projects supported by the World Diabetes Foundation in developing countries utilize any of the internationally recommended guidelines for screening and diagnosis of GDM, explore experiences on applicability and usefulness of the guidelines and barriers if any, in implementing the guidelines. These projects have reached out to thousands of pregnant women through capacity building and improvement of access to GDM screening and diagnosis in the developing world and therefore provide a rich field experience on the applicability of the guidelines in resource-poor settings. Design: A mixed methods approach using questionnaires and interviews was utilised to review 11 GDM projects. Two projects were conducted by the same partner; interviews were conducted in person or via phone by the first author with nine project partners and one responded via email. The interviews were analysed using content analysis. Results: The projects use seven different screening procedures and diagnostic criteria and many do not completely adhere to one guideline alone. Various challenges in adhering to the recommendations emerged in the interviews, including problems with screening women during the recommended time period, applicability of some of the listed risk factors used for (pre-screening, difficulties with reaching women for testing in

  8. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-01-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. The authors built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses their calibration philosophy and techniques, and describes some of the x-ray sources. Examples of actual calibration data are presented as well

  9. Facilities and Techniques for X-Ray Diagnostic Calibration in the 100-eV to 100-keV Energy Range

    Science.gov (United States)

    Gaines, J. L.; Wittmayer, F. J.

    1986-08-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well.

  10. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-06-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well

  11. Microelectronics Failure Analysis Techniques. A Procedural Guide

    Science.gov (United States)

    1980-01-01

    0.26 0.60 0. 142 0.33 Nitrogen 0.48 0. 143 Oxygen 0. 15 0. 144 Fluorine 0.11 0.146 Neon 0. 006 0. 148 Sodium 0.099 0.097 0. 150 0.15 Magnesium 0.093 0...urethane; silicones; varnishes Dynasolve 100 Dynaloy, Inc. Removal of potting epoxies Dynasolve 160 Dynaloy, Inc. Removal of some potting epoxies J-300...elements below fluorine without very restrictive windowless detectors. There are other important differences, partic- ularly in research applications, and

  12. Novel non-intercepting diagnostic techniques for low-emittance relativistic electron beams

    International Nuclear Information System (INIS)

    Moran, M.J.; Chang, B.

    1988-01-01

    Relativistic electron beams are being generated with emittances low enough that diffraction radiation can be used for beam diagnostics. Techniques based on diffraction radiation can be used to measure the beam transverse momentum distribution and to measure the transverse spatial distribution. The radiation is intense and can be in the visible spectral region where optical diagnostic techniques can be used to maximum advantage. 4 refs. 3 figs

  13. Two cases of colossal heamtometra in old women with a difficult preoperative diagnostic technique

    International Nuclear Information System (INIS)

    Aono, Kaname; Fukumoto, Satoru

    1980-01-01

    With the progress in diagnostic imaging techniques, the preoperative diagnostic technique for lesion in the pelvic cavity has become comparatively easy and its clinical usefulness is in high estimation. However, in case of an atypical lesion, it is not always easy to recognize the original organ by traditional imaging pattern. In the present report two cases of colossal hematometra in old women which presented a cystic lesion pattern are dealt with and discussed from a point of medical imagings for diagnosis. (author)

  14. Bone marrow aspiration and biopsy. Technique and considerations

    Directory of Open Access Journals (Sweden)

    R.A. Trejo-Ayala

    2015-10-01

    Full Text Available Bone marrow aspiration and bone marrow biopsy are invasive procedures in which good technical skill is crucial to obtain samples suitable for processing and diagnostic interpretation. The type and calibre of the needle is one of the main variables of the technique, and is selected on the basis of the age, gender and body mass of the patient. This article provides a practical, step-by-step guide to the technique for both procedures. It also discusses existing techniques for reducing the pain associated with the procedure, an essential aspect for the patient that if poorly handled, can force cancellation of the procedure.

  15. IDENTIFICATION OF CANINE VISCERAL LEISHMANIASIS IN A PREVIOUSLY UNAFFECTED AREA BY CONVENTIONAL DIAGNOSTIC TECHNIQUES AND CELL-BLOCK FIXATION

    Directory of Open Access Journals (Sweden)

    Tuanne Rotti ABRANTES

    2016-01-01

    Full Text Available After the report of a second case of canine visceral leishmaniasis (CVL in São Bento da Lagoa, Itaipuaçu, in the municipality of Maricá, Rio de Janeiro State, an epidemiological survey was carried out, through active search, totaling 145 dogs. Indirect immunofluorescence assay (IFA, enzyme-linked immunosorbent assay (ELISA, and rapid chromatographic immunoassay based on dual-path platform (DPP(r were used to perform the serological examinations. The parasitological diagnosis of cutaneous fragments was performed by parasitological culture, histopathology, and immunohistochemistry. In the serological assessment, 21 dogs were seropositive by IFA, 17 by ELISA, and 11 by DPP(r, with sensitivity of 66.7%, 66.7% and 50%, and specificity of 87.2%, 90.2% and 94%, respectively for each technique. The immunohistochemistry of bone marrow using the cell-block technique presented the best results, with six positive dogs found, three of which tested negative by the other parasitological techniques. Leishmania sp. was isolated by parasitological culture in three dogs. The detection of autochthonous Leishmania infantum in Itaipuaçu, and the high prevalence of seropositive dogs confirm the circulation of this parasite in the study area and alert for the risk of expansion in the State of Rio de Janeiro.

  16. [Have Case Loads of Radical Surgery for Prostate Cancer Been Concentrated in Hospitals with Robotic Equipment ?--Analyses with Questionnaire Survey and Diagnostic Procedure Combination (DPC) Data].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2016-04-01

    We investigated whether installation of robot-assisted surgical equipment in hospitals resulted in concentration of the case loads of radical prostatectomy. We selected 11 areas with populations of around 1 million or more where there were one or more hospitals with robotic equipment and 4 or more without it. In addition, annual changes of case loads for prostatectomy over 4 years from 2010 to 2013 were clearly determined in these areas. The case loads were determined based on the results of a questionnaire survey for the hospitals with robots and on the Diagnostic Procedures Combination data provided by the Ministry of Health, Labor and Wealth for those without such equipment. The concentration of the case loads was principally defined as when hospitals with robots had more predominant proportion of cases than those without them in the comparison between case loads prior to instillation of robots (or in the initial year of the study) and those in the final years. The 11 selected areas included 44 hospitals with robots and 156 without them. Concentration of case loads was found in 5 areas. In 4 areas, installation of robots did not have a specific relation to the distribution pattern s of case loads in hospitals with or without the equipment. The remaining 2 areas tended to have a weak but not definite concentration of case loads. In the areas in which installation did not influence case loads the further analysis revealed that their case loads had already been concentrated in the initial year (2010) of the study. Although the current results were found in a single department of the hospital, robotic installation may result in concentration of prostatectomy case loads for such hospitals in some areas. The current results are intriguing when we consider the future roles of acute care hospitals and beds in our country where the number of aged patients having chronic diseases will increase. In conclusion, installation of robotic equipment may result in concentration

  17. Mild cognitive impairment. Diagnostic value of different MR techniques

    International Nuclear Information System (INIS)

    Hauser, T.; Stieltjes, B.; Essig, M.; Thomann, P.A.

    2011-01-01

    In view of an increasingly aging population the prevalence of dementia is also expected to increase rapidly. As well as clinical, neuropsychological and laboratory procedures magnetic resonance imaging (MRI) plays an important role in the early diagnosis of dementia which is important in the precursor stage of mild cognitive impairment (MCI). On the one hand this stage is associated with an increased risk of dementia and on the other hand an early treatment in this stage could attenuate development of the disease. In addition to morphological changes different functional MRI techniques can help in the early diagnosis of dementia and the precursor stages. Moreover, it is important to detect those MCI patients who are at particularly risk for developing dementia. In the differentiation of converters to non-converters initial studies suggest that particularly voxel-based morphometry, MR spectroscopy and diffusion tensor imaging can provide important additional information. (orig.) [de

  18. Activity based costing of diagnostic procedures at a nuclear medicine center of a tertiary care hospital.

    Science.gov (United States)

    Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha

    2014-10-01

    Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments.

  19. Activity based costing of diagnostic procedures at a nuclear medicine center of a tertiary care hospital

    International Nuclear Information System (INIS)

    Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha

    2014-01-01

    Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments

  20. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  1. Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value

    DEFF Research Database (Denmark)

    Johnson, Thorsten R C; Bayrhof, Nicole; Huber, Armin

    2007-01-01

    Our aim was to determine the diagnostic value of myocardial tagging sequences with regard to the evaluable share of the cardiac cycle. Thirty-three patients were examined at 1.5 T using tagging sequences with gradient-echo (GRE) readout, 18 patients at 1.5 T with steady-state free precession (SSF...

  2. Prenatal radiation exposures at diagnostic procedures: methods to identify exposed pregnant patients

    International Nuclear Information System (INIS)

    Pettersson, H.; Sandborg, M.; Nilsson, J.; Olsson, S.

    2002-01-01

    Knowledge about frequency and doses to embryo/foetus from diagnostic radiology is of great importance both in the sense of estimating the radiation risks but also for optimizing the diagnostic procedures and making decisions regarding alternative procedures. In addition, the pregnant patient has the right to know the magnitude and type of radiation risks expected as a result of foetus exposure. From a risk perspective epidemiological data have shown that the embryo/foetus together with children experience higher radiation sensitivity in terms of induced leukemia and cancer compared to an adult population. Recent estimates give cancer excess lifetime mortality risks for whole body exposures of children and foetus (0-15 y age) of 0.06% (ICRP84, 2000) up to 0.14% per 10 mSv (BEIR-V 1990). In addition to the risk of cancer induction effects of cell killing, e.g. CNS abnormalities, cataracts, malformations, growth retardation, may occur. However, these effects are believed to have a threshold, about 100-200 mGy (ICRP84, 2000), and such foetus doses are rarely reached in diagnostic radiology procedures. There are 2 principal situations where foetus exposures may occur in diagnostic radiology; 1. The pregnancy of the patient is known at the time of examination, but due to the medical indications the examination can not be postponed or put forward in time, and there are no suitable alternative non-radiological procedures. 2. The pregnancy of the patient is not known at the time of examination, either due to the fact that the patient is unaware of her pregnancy or the medical personnel failed to obtain this information. The former situation may occur during the first few weeks from conception, whereas the latter situation may cover a greater gestation period

  3. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  4. Procedures for treating common cause failures in safety and reliability studies: Volume 2, Analytic background and techniques: Final report

    International Nuclear Information System (INIS)

    Mosleh, A.; Fleming, K.N.; Parry, G.W.; Paula, H.M.; Worledge, D.H.; Rasmuson, D.M.

    1988-12-01

    This report presents a framework for the inclusion of the impact of common cause failures in risk and reliability evaluations. Common cause failures are defined as that subset of dependent failures for which causes are not explicitly included in the logic model as basic events. The emphasis here is on providing procedures for a practical, systematic approach that can be used to perform and clearly document the analysis. The framework and the methods discussed for performing the different stages of the analysis integrate insights obtained from engineering assessments of the system and the historical evidence from multiple failure events into a systematic, reproducible, and defensible analysis. This document, Volume 2, contains a series of appendices that provide additional background and methodological detail on several important topics discussed in Volume 1

  5. THD Doppler procedure for hemorrhoids: the surgical technique.

    Science.gov (United States)

    Ratto, C

    2014-03-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called "dearterialization") can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called "mucopexy") can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Following adequate clinical assessment, patients undergo THD under general or spinal anesthesia, in either the lithotomy or the prone position. In all patients, distal Doppler-guided dearterialization is performed, providing the selective ligation of hemorrhoidal arteries identified by Doppler. In patients with hemorrhoidal/muco-hemorrhoidal prolapse, the mucopexy is performed with a continuous suture including the redundant and prolapsing mucosa and submucosa. The description of the surgical procedure is complemented by an accompanying video (see supplementary material). In long-term follow-up, there is resolution of symptoms in the vast majority of patients. The most common complication is transient tenesmus, which sometimes can result in rectal discomfort or pain. Rectal bleeding occurs in a very limited number of patients. Neither fecal incontinence nor chronic pain should occur. Anorectal physiology parameters should be unaltered, and anal sphincters should not be injured by following this procedure. When accurately performed and for the correct indications, THD is a safe procedure and one of the most effective treatments for hemorrhoidal disease.

  6. Development of advanced strain diagnostic techniques for reactor environments.

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Darryn D.; Holschuh, Thomas Vernon,; Miller, Timothy J.; Hall, Aaron Christopher; Urrea, David Anthony,; Parma, Edward J.,

    2013-02-01

    The following research is operated as a Laboratory Directed Research and Development (LDRD) initiative at Sandia National Laboratories. The long-term goals of the program include sophisticated diagnostics of advanced fuels testing for nuclear reactors for the Department of Energy (DOE) Gen IV program, with the future capability to provide real-time measurement of strain in fuel rod cladding during operation in situ at any research or power reactor in the United States. By quantifying the stress and strain in fuel rods, it is possible to significantly improve fuel rod design, and consequently, to improve the performance and lifetime of the cladding. During the past year of this program, two sets of experiments were performed: small-scale tests to ensure reliability of the gages, and reactor pulse experiments involving the most viable samples in the Annulated Core Research Reactor (ACRR), located onsite at Sandia. Strain measurement techniques that can provide useful data in the extreme environment of a nuclear reactor core are needed to characterize nuclear fuel rods. This report documents the progression of solutions to this issue that were explored for feasibility in FY12 at Sandia National Laboratories, Albuquerque, NM.

  7. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection; Praktische Roentgendiagnostik Orthopaedie und Unfallchirurgie. Indikation, Einstelltechnik, Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Flechtenmacher, Johannes [Ortho-Zentrum am Ludwigsplatz, Karlsruhe (Germany); Sabo, Desiderius [Klinik St. Elisabeth, Heidelberg (Germany). Sportopaedic Heidelberg

    2014-07-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  8. 2D and 3D optical diagnostic techniques applied to Madonna dei Fusi by Leonardo da Vinci

    Science.gov (United States)

    Fontana, R.; Gambino, M. C.; Greco, M.; Marras, L.; Materazzi, M.; Pampaloni, E.; Pelagotti, A.; Pezzati, L.; Poggi, P.; Sanapo, C.

    2005-06-01

    3D measurement and modelling have been traditionally applied to statues, buildings, archeological sites or similar large structures, but rarely to paintings. Recently, however, 3D measurements have been performed successfully also on easel paintings, allowing to detect and document the painting's surface. We used 3D models to integrate the results of various 2D imaging techniques on a common reference frame. These applications show how the 3D shape information, complemented with 2D colour maps as well as with other types of sensory data, provide the most interesting information. The 3D data acquisition was carried out by means of two devices: a high-resolution laser micro-profilometer, composed of a commercial distance meter mounted on a scanning device, and a laser-line scanner. The 2D data acquisitions were carried out using a scanning device for simultaneous RGB colour imaging and IR reflectography, and a UV fluorescence multispectral image acquisition system. We present here the results of the techniques described, applied to the analysis of an important painting of the Italian Reinassance: `Madonna dei Fusi', attributed to Leonardo da Vinci.

  9. Prenatal diagnostic procedures used in pregnancies with congenital malformations in 14 regions of Europe.

    Science.gov (United States)

    Garne, Ester; Loane, Maria; de Vigan, Catherine; Scarano, Gioacchino; de Walle, Hermien; Gillerot, Yves; Stoll, Claude; Addor, Marie-Claude; Stone, David; Gener, Blanca; Feijoo, Maria; Mosquera-Tenreiro, Carmen; Gatt, Miriam; Queisser-Luft, Annette; Baena, Neus; Dolk, Helen

    2004-11-01

    To investigate outcomes of ultrasound investigations (US) and invasive diagnostic procedures in cases of congenital malformations (CM), and to compare the use of invasive prenatal test techniques (amniocentesis (AC) versus chorionic villus sampling (CVS)) among European populations. Analysis of data from population-based registries of CM. 25 400 cases of CM recorded by 14 EUROCAT registries covering a total population of 1,013,352 births 1995-99. US were performed in 91% of cases, and positively detected CM in 35% of cases. AC was performed in 24% of the cases and CVS in 3% of cases. Thirty-eight percent of invasive tests gave positive results. Fifty-two percent of cases with maternal age > or = 35 years had an invasive test performed compared to 20% of cases with younger mothers. Considerable variation was found between registries in the uptake rate of invasive tests in cases with older maternal age and on the use of invasive tests with only four regions employing CVS techniques in at least a third of the cases having invasive tests. For chromosomal anomalies US gave positive results in 46% of cases with maternal age or = 35 years with US performed. Prenatal US was performed in 91% of all pregnancies with CM but the test was only positive in a third of the cases. There was large regional variation in the uptake rate of invasive tests with maternal age of 35 years or more. For every CVS carried out there were nine AC tests. US is an important tool in the prenatal diagnosis of chromosomal anomalies in Europe. Copyright 2004 John Wiley & Sons, Ltd.

  10. Rare gas dependence of vibration--vibration energy transfer processes: A diagnostic technique. Applications to CH2D2 and CH3F

    International Nuclear Information System (INIS)

    Apkarian, V.A.; Weitz, E.

    1979-01-01

    The rare gas dependence of V--V rates can be used as a diagnostic technique to identify different mechanisms of vibrational energy transfer and determine the rate constants for individual kinetic steps. The method is especially useful for the identification and measurement of rates of resonant vibrational energy transfer processes. Analytical and numerical solutions of pertinent model equations are presented and their range of applicability is discussed. The technique is applied to CH 2 D 2 and CH 3 F. In CH 2 D 2 results of studies on ν 9 , [ν 1 , ν 6 ] and states in the 2000 cm -1 region are presented where the application of the technique has made it possible to identify the pathways leading to population of these states and to assign rate constants to some of the steps involved. In CH 3 F, by studying the Ar dependence of the V--V rates of the [ν 2 , ν 5 ] and [ν 1 , ν 4 ] states it has been possible to construct a complete map of energy transfer pathways which can explain all experimental observations for this system, to date. The general applicability of the technique and its potential application to other systems is also considered

  11. Additional radiation dose to population due to X-ray diagnostic procedures

    International Nuclear Information System (INIS)

    Chougule, A.

    2006-01-01

    Full text of publication follows: Discovery of X rays has revolutionised the medical diagnosis but the fact that the diagnostic radiological procedures contribute about 80 to 90 % of the radiation dose to population as compared to other man made radiation sources cannot be ignored especially when X ray diagnostic facilities are being made available to larger section of the society. The estimated frequency of radiological procedures in India is 12,000 procedures/ year/100,000 population, though it is quite less as compared to developed countries, its increasing day by day. As part of the project, a radiation protection survey of X ray installations and patient radiation dose measurement during various radiological procedures was undertaken. 193 X ray installations were surveyed and the radiation doses received by the patient during various radiological procedure was measured. For measurement of radiation doses, CaSO 4 : Dy thermoluminescence (T.L.) discs of size 13.3 mm diameter and 0.8 mm thickness were used. Pre annealed T.L. discs were fixed by adhesive tape on the patient skin at the center of entrance beam before the exposure. After exposure the T.L. discs were estimated f or entrance skin dose during that particular projection/ examination. 10,000 measurements at different centers during various radiological procedures were done. It was found that chest radiography accounts for 37 % of all radiological procedures and further it was observed that 70 % of the chest X rays were normal with out any pathology indicating scope for curtailing the unwarranted radiological procedures. The special investigations like barium swallow, barium meal and fallow through accounts for about 1.5 % of the total radiological procedures. The entrance skin dose [E.S.D.] during chest radiography was 0.3 + 0.1 mGy where as during K.U.B. and cervical spine radiography it was 6.2 + 1.1 mGy and 5.1 + 0.9 mGy respectively. The details of frequency of various radiological procedures and the

  12. A comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures.

    Science.gov (United States)

    Echeverria, Angela; Krajcer, Zvonimir

    2016-01-01

    Vascular closure devices allow for early sheath removal, allowing for earlier patient mobilization The Boomerang vascular access management system does not alter arterial integrity for future interventions Access site complications provide significant morbidity in diagnostic and therapeutic interventions. © 2016 Wiley Periodicals, Inc.

  13. Diagnostic imaging techniques in Rubinstein-Taybi syndrome

    International Nuclear Information System (INIS)

    Albanese, A.; Carcione, A.; Benenati, A.; Albano, S.; Rubino, F.P.; Reina, C.; Verde, V.; Giuffre, L.; Corsello, G.; Cammarata, M.; Piccione, M.

    1991-01-01

    Both etiology and pathogenesis of Rubinstein-Taybi syndrome (RTS) are still questionable, even though a genetic factor seems to be certain. A typical face, psychomotor delay, and thumb and halluces abnormalities (big, prevalently short, and often 'spoon-like' toes) are the main characteristic patterns of RTS. Eight subjects (4 male and 3 female children aged 26 days-7 years, and a 31-year old woman, mother of 1 of the affected children) with different signs of RTS were studied over the last 3 years. The results are here reported, with a special emphasis on malformations detected with conventional radiography (Rx), Computerized Tomography (CT), and ultrasound (US). Evaluated parameters were thumbs and halluces (Rx), bone age and skeleton (Rx), cranium (Rx) and encephalon (US, CT), cryptochidism (US, CT), and urogical (Rx, US) and carciovascolar (US) system. Atypical face and psycomotor delay were found in all cases, while thumb and halluces abnormalities were observed only in 6 cases. Among several clinical signs of RTS, we found: severe (<3rd centile) bone maturation delay in 4 cases; skull volume reduction (<50th centile) in 3 subjects and microcrania in 4; skeletal abnormalities in 7 cases (5 of them positive for bilateral coxofemoral abnormalities); urinary tract (4 cases) and cardiovascular (3 cases) malformation; and cryptorcidism in 3 of 4 males. A case was diagnosed during neonatal period (within the first month of life) it was a rare case associated with a variant form of Dandy-Walker anomaly; semiologic similarities were observed between mother and daughter patients. X-rays, US and CT rarely play an important role in the diagnosis of RTS, considering the several clinical signs, mainly tha face, affecting the patients. However, diagnostic imaging techniques help diagnose hidden malformations and confirm and integrate clinical signs

  14. Comparison of bone tunnel and suture anchor techniques in the modified Broström procedure for chronic lateral ankle instability.

    Science.gov (United States)

    Hu, Chang-Yong; Lee, Keun-Bae; Song, Eun-Kyoo; Kim, Myung-Sun; Park, Kyung-Soon

    2013-08-01

    The modified Broström procedure is frequently used to treat chronic lateral ankle instability. There are 2 common methods of the modified Broström procedure, which are the bone tunnel and suture anchor techniques. To compare the clinical outcomes of the modified Broström procedure using the bone tunnel and suture anchor techniques. Cohort study; Level of evidence, 2. Eighty-one patients (81 ankles) treated with the modified Broström procedure for chronic lateral ankle instability constituted the study cohort. The 81 ankles were divided into 2 groups, namely, a bone tunnel technique (BT group; 40 ankles) and a suture anchor technique (SA group; 41 ankles). The Karlsson score, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, anterior talar translation, and talar tilt angle were used to evaluate clinical and radiographic outcomes. The BT group consisted of 32 men and 8 women with a mean age of 34.8 years at surgery and a mean follow-up duration of 34.2 months. The SA group consisted of 33 men and 8 women with a mean age of 33.3 years at surgery and a mean follow-up duration of 32.8 months. Mean Karlsson scores improved significantly from 57.0 points preoperatively to 94.9 points at final follow-up in the BT group and from 59.9 points preoperatively to 96.4 points at final follow-up in the SA group. Mean AOFAS scores also improved from 64.2 points preoperatively to 97.8 points at final follow-up in the BT group and from 70.3 points preoperatively to 97.4 points at final follow-up in the SA group. Mean anterior talar translations in the BT group and SA group improved from 9.0 mm and 9.2 mm preoperatively to 6.5 mm and 6.8 mm at final follow-up, respectively. Mean talar tilt angles were 12.0° in the BT group and 12.5° in the SA group preoperatively and 8.8° at final follow-up for both groups. No significant differences were found between the 2 groups in terms of the Karlsson score, AOFAS score, anterior talar translation, and talar tilt

  15. [THE CYTOMETRIC TECHNIQUE OF BINDING OF EOSIN-5-MALEIMIDE IN DIAGNOSTIC OF INHERENT SPHEROCYTOSIS].

    Science.gov (United States)

    Kuzminova, J A; Plyasunova, S A; Jogov, V V; Smetanina, N S

    2016-03-01

    The laboratory diagnostic of inherent spherocytosis is based on detection of spherocytes in peripheral blood, decreasing of index of sphericity, decreasing of osmotic resistance of erythrocytes. The new test of diagnostic of hereditary spherocytosis build on molecular defect was developed on the basis of binding extracellular fragments of protein of band 3 with eosin-5-maleimide (EMA-test). The study was carried out to implement comparative analysis of sensitivity and specificity of techniques applied to diagnose inherent spherocytosis. The sampling of 94 patients with various forms of anemias was analyzed All patients were applied complex clinical laboratory examination including analysis of osmotic resistance of erythrocytes, erythrocytometry and EMA-test as specific techniques of diagnostic of inherent spherocytosis. In 51 out of 94 patients (54%) decreasing of values of EMA-test was detected and in 47 patients diagnosis of inherent spherocytosis was confirmed. The standard values of EMA-test were established in 43 patients (46%) and 12 patients out of them with established diagnosis of inherent spherocytosis. Therefore, sensitivity of EMA-test made up to 79% and specificity - 80%. The most sensitive techniques of diagnostic remain osmotic resistance of erythrocytes (91%) and index of sphericity (up to 96%). But the highest specificity in this respect has EMA-test (80%). Nowadays, none of implemented techniques of diagnostic of inherent spherocytosis can be applied as a universal one. The implementation of complex examination is needed for proper diagnostic of disease.

  16. The influence on finite measurement accuracy on the SWE-to-PWE antenna diagnostics technique

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Breinbjerg, Olav; Frandsen, Aksel

    2006-01-01

    A new antenna diagnostics technique based on the transformation of the spherical wave expansion (SWE) into the plane wave expansion (PWE) is proposed. The new technique allows the recovery of the plane wave spectrum in the visible region, and in principle also in part of the invisible region, from...

  17. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Directory of Open Access Journals (Sweden)

    Mingyue Luo

    Full Text Available To evaluate the diagnostic value of multidetector CT (MDCT and its multiplanar reformation (MPR, volume rendering (VR and virtual bronchoscopy (VB postprocessing techniques for primary trachea and main bronchus tumors.Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology.Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6, tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16, extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1, longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1, morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1 and extents (mild, n = 5; moderate, n = 7; severe, n = 19, distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10, and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density

  18. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Science.gov (United States)

    Luo, Mingyue; Duan, Chaijie; Qiu, Jianping; Li, Wenru; Zhu, Dongyun; Cai, Wenli

    2015-01-01

    To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without

  19. A brief review on the efficacy of different possible and nonpharmacological techniques in eliminating discomfort of local anesthesia injection during dental procedures

    Science.gov (United States)

    Davoudi, Amin; Rismanchian, Mansour; Akhavan, Ali; Nosouhian, Saeid; Bajoghli, Farshad; Haghighat, Abbas; Arbabzadeh, Farahnaz; Samimi, Pouran; Fiez, Atiyeh; Shadmehr, Elham; Tabari, Kasra; Jahadi, Sanaz

    2016-01-01

    Dental anxiety and fear of needle injection is one of the most common problems encountered by dental practitioners, especially in the pediatric patient. In consequences, it might affect the patient's quality of life. Several methods are suggested to lower the discomfort of local anesthesia injection during dental procedures. Desensitization of injection site is one of the recommended strategies. Among chemical anesthetic topical agents that are effective but might have allergic side effects, using some nonpharmacological and safe techniques might be useful. This study aimed to overview the efficacy of using cooling techniques, mostly by ice or popsicles, warming or pH buffering of drug, and using modern devices to diminish the discomfort of local anesthesia injection during dental procedures. PMID:26957683

  20. Recanalization strategy for chronic total occlusions with tapered and stiff-tip guidewire. The results of CTO new techniQUE for STandard procedure (CONQUEST) trial.

    Science.gov (United States)

    Mitsudo, Kazuaki; Yamashita, Takehiro; Asakura, Yasushi; Muramatsu, Toshiya; Doi, Osamu; Shibata, Yoshisato; Morino, Yoshihiro

    2008-11-01

    The success rate of percutaneous coronary intervention (PCI) for chronic total coronary occlusion (CTO) lesions varies depending on the guidewire manipulation skills of the operator. The standardization of guidewire technique is very important. A new technique with a new tapered wire (Conquest, Confianza Pro) was tested to verify effectiveness for higher initial success rates and standardization of PCI for CTO. A prospective, multicenter registry was conducted at 6 investigational sites. In the CONQUEST trial, The CTO lesions were treated by using an intermediate guidewire to cross the lesion. If it did not cross, the guidewire was changed to the Conquest guidewire. If it did not cross, "seesaw-wiring" or the "parallel-wire technique" was performed. The primary endpoint was the initial procedural success rate. A total of 110 patients representing 116 CTO lesions were treated from July 2003 through March 2004. The procedural success rate was 86.2% on the first try, and 88.8% on the second try, respectively. The guidewire success rate on the second try was 90.5% during the hospital stay; no deaths, or acute myocardial infarctions were confirmed. Two patients deteriorated into tamponade, and surgical or percutaneous drainage was performed in each patient without any sequelae. A guidewire technique in PCI for CTOs that starts with the intermediate guidewire and moves to the Confianza Pro tapered guidewire, either alone or by performing a see-saw or parallel-wire technique, can achieve a high initial success rate with an acceptably low major complication rate.

  1. Detecting and Treating Cervical Cancer Using Diagnostic Imaging Techniques and Radiotherapy. IAEA Support to Latin America and the Caribbean

    International Nuclear Information System (INIS)

    Dixit, Aabha

    2016-01-01

    The diagnosis and treatment of cervical cancer are an important area of cooperation in the field of human health between Member States in the Latin America and the Caribbean region and the IAEA. Nuclear medicine and radiation therapy offer rapid diagnosis and effective treatment for various types of cancer. Cervical cancer is usually curable if caught early and treated. Member States in the region have shown a very strong commitment to enhancing access to radiation oncology and to assuring the quality of treatment. Many are focusing on education and training and the modernization of clinical infrastructure in national institutions responsible for health care and services.

  2. The state-of-the Art of the Established Conventional and Advanced NDE-Techniques and Procedures for Defect Detection and Sizing - Part D: application of ultrasonic techniques for the inspection of austenitic components

    International Nuclear Information System (INIS)

    Edelmann, X.

    1997-01-01

    Ultrasonic examination of austenitic welds is possible in many cases but special techniques have often to be applied. The 'Handbook on the Ultrasonic Examination of Austenitic Welds' of the International Institute of Welding gives advice how to devise procedures for the detection, location and evaluation of ultrasonic indications of weld defects. In most circumstances it is necessary to use angled longitudinal wave probes. Austenitic weld examination is more complex and more expensive than ferritic weld examination. Detection and characterization of intergranular stress corrosion cracking has been improved by special qualification programs of the EPRI NDE Center. Dissimilar Metal welds are difficult to examine. Techniques have been developed for detection of circumferential and axial defects. Cast stainless steel structures are in general still extremely difficult to examine as a recent round robin test of the PISC program has shown. Mechanized examination with adequate data acquisition processing and presentation techniques enables better interpretation of examination results. (author)

  3. Avoid Filling Swiss Cheese with Whipped Cream; Imputation Techniques and Evaluation Procedures for Cross-Country Time Series

    OpenAIRE

    Michael Weber; Michaela Denk

    2011-01-01

    International organizations collect data from national authorities to create multivariate cross-sectional time series for their analyses. As data from countries with not yet well-established statistical systems may be incomplete, the bridging of data gaps is a crucial challenge. This paper investigates data structures and missing data patterns in the cross-sectional time series framework, reviews missing value imputation techniques used for micro data in official statistics, and discusses the...

  4. Assessment of African Swine Fever Diagnostic Techniques as a Response to the Epidemic Outbreaks in Eastern European Union Countries: How To Improve Surveillance and Control Programs.

    Science.gov (United States)

    Gallardo, C; Nieto, R; Soler, A; Pelayo, V; Fernández-Pinero, J; Markowska-Daniel, I; Pridotkas, G; Nurmoja, I; Granta, R; Simón, A; Pérez, C; Martín, E; Fernández-Pacheco, P; Arias, M

    2015-08-01

    This study represents a complete comparative analysis of the most widely used African swine fever (ASF) diagnostic techniques in the European Union (EU) using field and experimental samples from animals infected with genotype II ASF virus (ASFV) isolates circulating in Europe. To detect ASFV, three different PCRs were evaluated in parallel using 785 field and experimental samples. The results showed almost perfect agreement between the Universal ProbeLibrary (UPL-PCR) and the real-time (κ = 0.94 [95% confidence interval {CI}, 0.91 to 0.97]) and conventional (κ = 0.88 [95% CI, 0.83 to 0.92]) World Organisation for Animal Health (OIE)-prescribed PCRs. The UPL-PCR had greater diagnostic sensitivity for detecting survivors and allows earlier detection of the disease. Compared to the commercial antigen enzyme-linked immunosorbent assay (ELISA), good-to-moderate agreement (κ = 0.67 [95% CI, 0.58 to 0.76]) was obtained, with a sensitivity of 77.2% in the commercial test. For ASF antibody detection, five serological methods were tested, including three commercial ELISAs, the OIE-ELISA, and the confirmatory immunoperoxidase test (IPT). Greater sensitivity was obtained with the IPT than with the ELISAs, since the IPT was able to detect ASF antibodies at an earlier point in the serological response, when few antibodies are present. The analysis of the exudate tissues from dead wild boars showed that IPT might be a useful serological tool for determining whether or not animals had been exposed to virus infection, regardless of whether antibodies were present. In conclusion, the UPL-PCR in combination with the IPT was the most trustworthy method for detecting ASF during the epidemic outbreaks affecting EU countries in 2014. The use of the most appropriate diagnostic tools is critical when implementing effective control programs. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Assessment of African Swine Fever Diagnostic Techniques as a Response to the Epidemic Outbreaks in Eastern European Union Countries: How To Improve Surveillance and Control Programs

    Science.gov (United States)

    Nieto, R.; Soler, A.; Pelayo, V.; Fernández-Pinero, J.; Markowska-Daniel, I.; Pridotkas, G.; Nurmoja, I.; Granta, R.; Simón, A.; Pérez, C.; Martín, E.; Fernández-Pacheco, P.; Arias, M.

    2015-01-01

    This study represents a complete comparative analysis of the most widely used African swine fever (ASF) diagnostic techniques in the European Union (EU) using field and experimental samples from animals infected with genotype II ASF virus (ASFV) isolates circulating in Europe. To detect ASFV, three different PCRs were evaluated in parallel using 785 field and experimental samples. The results showed almost perfect agreement between the Universal ProbeLibrary (UPL-PCR) and the real-time (κ = 0.94 [95% confidence interval {CI}, 0.91 to 0.97]) and conventional (κ = 0.88 [95% CI, 0.83 to 0.92]) World Organisation for Animal Health (OIE)-prescribed PCRs. The UPL-PCR had greater diagnostic sensitivity for detecting survivors and allows earlier detection of the disease. Compared to the commercial antigen enzyme-linked immunosorbent assay (ELISA), good-to-moderate agreement (κ = 0.67 [95% CI, 0.58 to 0.76]) was obtained, with a sensitivity of 77.2% in the commercial test. For ASF antibody detection, five serological methods were tested, including three commercial ELISAs, the OIE-ELISA, and the confirmatory immunoperoxidase test (IPT). Greater sensitivity was obtained with the IPT than with the ELISAs, since the IPT was able to detect ASF antibodies at an earlier point in the serological response, when few antibodies are present. The analysis of the exudate tissues from dead wild boars showed that IPT might be a useful serological tool for determining whether or not animals had been exposed to virus infection, regardless of whether antibodies were present. In conclusion, the UPL-PCR in combination with the IPT was the most trustworthy method for detecting ASF during the epidemic outbreaks affecting EU countries in 2014. The use of the most appropriate diagnostic tools is critical when implementing effective control programs. PMID:26041901

  6. PRECONCEPTION AND PRENATAL DIAGNOSTIC TECHNIQUES ACT 1994 AND ITS MAIN ROLE TO CURB SEX DETERMINATION AND SEX SELECTION

    OpenAIRE

    Adv. Vaishali V. Waghmare; Dr. (Mrs) Hema Menon

    2016-01-01

    India has a male dominated culture where women are treated like a commodity and slave. Our Indian society gives preference only to the Son not to female because of which girls' child is not heartily welcomed and discrimination against girl child still prevails. Sex selective abortion is one of major issue in recent era in relation to violence against women under which the Ultrasonography machine plays an important role of sex detection. Main cause for sex selection are Patriarchal system, Do...

  7. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  8. The Jejunal Serosal Patch Procedure: A Successful Technique for ...

    African Journals Online (AJOL)

    Background: The selection of the most appropriate technique for the repair of peptic ulcer perforations, especially when the initial attempt of closure has failed have been the concern of many surgeons. Since the experimental report regarding the jejunal serosal patch procedure by Koboldin in 1963, authors have reported its ...

  9. Isotopic and other techniques for organic micronutrient analysis and development of quality assurance procedures. Report of a consultants meeting

    International Nuclear Information System (INIS)

    2001-01-01

    between expert and non-expert laboratories for vitamin A/carotenoids, folate, and other B vitamins; (iii) circulate existing food and biological CRMs and other QC material to existing and new networks of laboratories in developing countries for the analysis of vitamin A/carotenoids, folate, and other B vitamins; (iv) develop accessible/inexpensive control materials for these vitamins; (v) develop isotopically labeled reference materials (isolates and intrinsically labeled foods) for use in bioavailability studies and (vi) develop appropriate LC-MS procedures for vitamin A/carotenoids and folates in regional centers. (author)

  10. Quality control procedure for a general diagnostic x-ray machine

    International Nuclear Information System (INIS)

    Md Saion Salikin; Mazlyfarina Mohamad

    2001-01-01

    Performance tests of a particular medical diagnostic x-ray machine have to be carried out regularly in order to ensure that the machine always complies with the required standard. A performance report which is prepared based on the performance tests on the x-ray machine is used as one of the requirement by the authority for issuance and renewal licence to operate and use of the x-ray machine in a clinic or hospital. The Ministry of Health will only issue a licence to the clinic or hospital to use and operate x-ray machines, if the machines have complied with the standards. The clinic or hospital may get the service to carry out performance tests on a diagnostic x-ray machine from any licence H holder, issued by the authority under Atomic Energy Licensing Act 1984. A comparative study between the standard procedure and other procedures on performance test of a general diagnostic x-ray machine is carried out and presented in brief in this paper. The criteria for compliance or otherwise as required by the Ministry of Health Malaysia is discussed and explained in brief. (Author)

  11. Automated synthesis of image processing procedures using AI planning techniques

    Science.gov (United States)

    Chien, Steve; Mortensen, Helen

    1994-01-01

    This paper describes the Multimission VICAR (Video Image Communication and Retrieval) Planner (MVP) (Chien 1994) system, which uses artificial intelligence planning techniques (Iwasaki & Friedland, 1985, Pemberthy & Weld, 1992, Stefik, 1981) to automatically construct executable complex image processing procedures (using models of the smaller constituent image processing subprograms) in response to image processing requests made to the JPL Multimission Image Processing Laboratory (MIPL). The MVP system allows the user to specify the image processing requirements in terms of the various types of correction required. Given this information, MVP derives unspecified required processing steps and determines appropriate image processing programs and parameters to achieve the specified image processing goals. This information is output as an executable image processing program which can then be executed to fill the processing request.

  12. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  13. Development of technique for diagnostics of social reserves of development of collective labour potential

    OpenAIRE

    Голубєв, Станіслав Миколайович

    2015-01-01

    The problems of diagnostics of social reserves of the collective labour potential are considered in the article. The aim of this study is to develop diagnostic techniques of social reserves of the collective labour potential in the work and the essence of the concept of "social reserves" as a subject of study of economics and their features in the study of collective labour potential. The use of these reserves can increase the efficiency of the labour collective processes by improving coopera...

  14. Determining quantitative road safety targets by applying statistical prediction techniques and a multi-stage adjustment procedure.

    Science.gov (United States)

    Wittenberg, P; Sever, K; Knoth, S; Sahin, N; Bondarenko, J

    2013-01-01

    Due to substantial progress made in road safety in the last ten years, the European Union (EU) renewed the ambitious agreement of halving the number of persons killed on the roads within the next decade. In this paper we develop a method that aims at finding an optimal target for each nation, in terms of being as achievable as possible, and with the cumulative EU target being reached. Targets as an important component in road safety policy are given as reduction rate or as absolute number of road traffic deaths. Determination of these quantitative road safety targets (QRST) is done by a top-down approach, formalized in a multi-stage adjustment procedure. Different QRST are derived under consideration of recent research. The paper presents a method to break the national target further down to regional targets in case of the German Federal States. Generalized linear models are fitted to data in the period 1991-2010. Our model selection procedure chooses various models for the EU and solely log-linear models for the German Federal States. If the proposed targets for the EU Member States are attained, the sum of fatalities should not exceed the total value of 15,465 per year by 2020. Both, the mean level and the range of mortality rates within the EU could be lowered from 28-113 in 2010 to 17-41 per million inhabitants in 2020. This study provides an alternative to the determination of safety targets by political commitments only, taking the history of road fatalities trends and population into consideration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Diagnostic and therapeutic peroral cholangioscopy

    Directory of Open Access Journals (Sweden)

    Jong Ho Moon

    2012-01-01

    Full Text Available Peroral cholangioscopy (POC provides direct visualization of the bile duct and facilitates diagnostic or therapeutic intervention. The currently available single-operator POC systems are "Mother-baby" scope system, SpyGlass direct visualization system, and direct POC using a regular ultra-slim upper endoscope. Direct POC using an ultra-slim upper endoscope having a larger 2-mm working channel can provide a valuable and economic solution for evaluating bile-duct lesions. Main diagnostic procedures under direct POC are visual characterization and optically guided target biopsy for the indeterminate bile duct lesion. Image-enhanced endoscopy such as narrow-band imaging has shown promise for more detailed evaluation of mucosal abnormality and can be performed under direct POC. Intracorporeal lithotripsy such as electrohydraulic lithotripsy or laser lithotripsy is a main therapeutic intervention of direct POC for patients with bile duct stones that are resistant to conventional endoscopic stone-removal procedures. Besides, tumor ablation therapy, such as photodynamic therapy and argon plasma coagulation may be also performed using direct POC. Further developments of the endoscope and specialized accessories or devices are expected to facilitate diagnostic and therapeutic role of this cholangioscopic procedure.

  16. Overview of radiation protection programme in nuclear medicine facility for diagnostic procedures

    International Nuclear Information System (INIS)

    Ahmed, Ezzeldein Mohammed Nour Mohammed

    2015-02-01

    This project was conducted to review Radiation Protection Program in Nuclear Medicine facility for diagnostic procedures which will provide guide for meeting the standard and regulatory requirements in diagnostic nuclear medicine. The main objective of this project is to keep dose to staff, patient and public as low as reasonably achievable (ALARA). The specific objectives were to review the Radiation Protection Program (RPP) in diagnostic nuclear medicine and to make some recommendation for improving the level of radiation protection in diagnostic nuclear medicine that will help to control normal exposure and prevent or mitigate potential exposure. The methodology used is review of various documents. The review showed that if the Radiation Protection Program is inadequate it leads to unjustified exposure to radiation. Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a qualified Radiation Protection Officer (RPO) should be appointed to lay down and oversee a radiation protection in the nuclear medicine department. The RPO must be given the full authority and the adequate time to enable him to perform his duties effectively. (au)

  17. Sonography as a new diagnostic procedure for investigating abnormalities of the shoulder

    International Nuclear Information System (INIS)

    Rapf, C.; Furtschegger, A.; Resch, H.; Innsbruck Univ.

    1986-01-01

    Eighty-one sonographic examinations of patients with complaints relating to the shoulder joint have shown that this is the method next in value to radiological examination. So far, lesions of the rotator cuff and of the long head of the biceps could only be demonstrated by invasive procedures such as arthrography or arthroscopy. In these situations, sonography attains a similar accuracy. Diffuse lesions can also be diagnosed correctly, making arthrography and arthroscopy unnecessary. In addition, sonography can demonstrate inflammatory and degenerative changes and incomplete sub-acromial and intermediary tears of the rotator cuff, unlike conventional diagnostic methods. In future, arthrography and arthroscopy will only be necessary as additional diagnostic methods if sonography remains inconclusive. (orig.) [de

  18. Combined orthognathic distraction procedure: Le Fort I maxillary osteotomy and mandibular curvilinear distraction osteogenesis. A new technique for craniofacial management.

    Science.gov (United States)

    Schendel, Stephen A; Hazan-Molina, Hagai; Aizenbud, Dror

    2014-04-01

    Dentofacial deformities are traditionally treated by maxillary and mandibular osteotomies conducted separately or simultaneously. Recently, distraction osteogenesis has become an irreplaceable part of the surgical armamentarium, for its ability to induce new bone formation between the surfaces of bone segments that are gradually separated by incremental traction, along with a simultaneous expansion of the surrounding soft-tissue envelope. The aim of this article is to describe a combined surgical technique consisting of simultaneous maxillary Le Fort I advancement and mandibular surgical repositioning by means of bilateral sagittal split osteotomy with a curvilinear distractor based on a preliminary computerized presurgical prediction.

  19. Theoretical modelling of experimental diagnostic procedures employed during pre-dose dosimetry of quartz

    International Nuclear Information System (INIS)

    Pagonis, V.; Chen, R.; Kitis, G.

    2006-01-01

    The pre-dose technique in thermoluminescence (TL) is used for dating archaeological ceramics and for accident dosimetry. During routine applications of this technique, the sensitisation of the quartz samples is measured as a function of the annealing temperature, yielding the so-called thermal activation characteristic (TAC). The measurement of multiple TACs and the study of the effect of UV-radiation on the TL sensitivity of quartz are important analytical and diagnostic tools. In this paper, it is shown that a modified Zimmerman model for quartz can successfully model the experimental steps undertaken during a measurement of multiple TACs. (authors)

  20. Textbook of focusing techniques in diagnostic radiography. 5. new rev. ed.

    International Nuclear Information System (INIS)

    Bosnjakovic-Buescher, S.; Riegler-Bubeck, C.; Zimmer-Brossy, M.; Bast, B.

    1998-01-01

    This 5th edition of the standard work on focusing techniques in diagnostic radiography is a guide for X-ray medical technicians and radiologists wishing to optimize their skills and produce images of high technical standard and diagnostic value. The major part of the textbook deals with the focusing and imaging techniques for evaluation of the skeleton and inner body organs. The new edition includes the current legal provisions for radiological protection and the latest quality assurance legislation. It is an indispensable source of reference for clinical departments, radiographic practice, and training institutions. (orig./CB) [de

  1. Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

    International Nuclear Information System (INIS)

    Akhan, Okan; Islim, Filiz; Balci, Sinan; Erbahceci, Aysun; Akpınar, Burcu; Ciftci, Turkmen; Akinci, Devrim

    2016-01-01

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

  2. Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Islim, Filiz, E-mail: fislim@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Balci, Sinan, E-mail: snnbalci@gmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Erbahceci, Aysun, E-mail: aysunerbahceci@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Akpınar, Burcu, E-mail: burcu-akpinar@yahoo.com; Ciftci, Turkmen, E-mail: turkmenciftci@yahoo.com; Akinci, Devrim, E-mail: akincid@hotmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey)

    2016-06-15

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

  3. Prenatal Radiation exposures at diagnostic procedures: methods to identify exposed pregnant patients

    International Nuclear Information System (INIS)

    Pettersson, H.; Sandborg, M.; Nilsson, J.; Olsson, S.; Hellman, S.; Helmrot, E.; Persliden, J.; Cederlund, T.

    2003-01-01

    Knowledge about frequency and doses to embryo/foetus from diagnostic radiology is of great importance both in the sense of estimating the radiation risks but also for optimizing the diagnostic procedures and making decisions regarding alternative procedures. In addition, the pregnant patient has a right to know the magnitude and type of radiation risks expected as a result of foetus exposure. From a risk perspective epidemiological data has shown that the embryo/foetus together with children experience higher radiation sensitivity in terms of induced leukemia and cancer compared to an adult population. Recent estimates give cancer excess lifetime mortality risks for whole body exposures of children and foetus (0-15 y age) of 0.06% up to 0.14% per 10 mSv. In addition to the risk of cancer induction effects of cell killing, e.g. CNS abnormalities, cataracts, malformations, growth retardation, may occur. However, these effects are believed to have a threshold, about 100-200 mGy, and such foetus doses are rarely reached in diagnostic radiology procedures. There are 2 principal situations where foetus exposures may occur in diagnostic radiology; The pregnancy of the patient is known at the time of examination, but due to the medical indications the examination can not be postponed or put forward in time, and there are no suitable alternative non-radiological procedures. The pregnancy of the patient is not known at the time of examination, either due to the fact that the patient is unaware of her pregnancy or the medical personnel failed to obtain this information. The former situation may occur during the first few weeks from conception, whereas the latter situation may cover a greater gestation period. The frequency of foetus exposure is not well documented. In Sweden, there are well-established routines to track down pregnant patients before examinations are being performed. However, there are no general obligations or routines to document the cases either (i) when

  4. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    Science.gov (United States)

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome.

  5. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  6. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-01-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes

  7. Procedures and techniques for the management of experimental and exotic fuel from research and test reactors in France

    International Nuclear Information System (INIS)

    Raisonnier, D.

    1999-01-01

    Since 1995, the Commissariat a I'Energie Atomique CEA has implemented a three point fuel management plan. One of the three points, the removal and the reprocessing of a wide range of spent fuels stored in different facilities in Saclay, Grenoble and Cadarache nuclear research centers, is described. The COGEMA Group has developed and implemented a comprehensive set of solutions for the management of research reactor and exotic fuels. It includes transport casks, storage casks or interim storage facilities at the reactor site, or at a centralized interim storage, as well as spent fuel reprocessing, material recycling and waste conditioning. (author)

  8. Refining a complex diagnostic construct: subtyping Dysthymia with the Shedler-Westen Assessment Procedure-II.

    Science.gov (United States)

    Huprich, Steven K; Defife, Jared; Westen, Drew

    2014-01-01

    We sought to determine whether meaningful subtypes of Dysthymic patients could be identified when grouping them by similar personality profiles. A random, national sample of psychiatrists and clinical psychologists (n=1201) described a randomly selected current patient with personality pathology using the descriptors in the Shedler-Westen Assessment Procedure-II (SWAP-II), completed assessments of patients' adaptive functioning, and provided DSM-IV Axis I and II diagnoses. We applied Q-factor cluster analyses to those patients diagnosed with Dysthymic Disorder. Four clusters were identified-High Functioning, Anxious/Dysphoric, Emotionally Dysregulated, and Narcissistic. These factor scores corresponded with a priori hypotheses regarding diagnostic comorbidity and level of adaptive functioning. We compared these groups to diagnostic constructs described and empirically identified in the past literature. The results converge with past and current ideas about the ways in which chronic depression and personality are related and offer an enhanced means by which to understand a heterogeneous diagnostic category that is empirically grounded and clinically useful. © 2013 Published by Elsevier B.V.

  9. Real time CT-fluoroscopy: diagnostic and therapeutic applications

    International Nuclear Information System (INIS)

    Mey, J. de; Op de Beeck, B.; Meysman, M.; Noppen, M.; Maeseneer, M. de; Vanhoey, M.; Vincken, W.; Osteaux, M.

    2000-01-01

    The synergetic progression of CT technology and computer hardware has made ultrafast acquisition and image reconstruction possible. This has lead to the availability of CT interactive diagnosis and therapeutic procedures. Making use of our own material (337 intervention procedures during the last 17 months), we have compared our techniques and results to the recent literature data. One of the advantages of the biopsy technique is an improved sensitivity for neoplastic lesions, most certainly in cases of intrapulmonary lesions, surrounded by aerated tissue (now 94% compared to 87% in our previous study). A second advantage is the safety of the technique (only one major complication in our series). Fluid collection drainages, and more complex interventions like local injection of drugs, radio-frequency ablation, wire hook placement and ethanol injection were performed without complication. Yet another interesting feature is the shortening of the procedure time (reduced in average to an 'in-room' time of less than 30 min), which has definite economical implications. Furthermore it increases the patient's comfort and safety, and extends the scope of outpatient procedures (80% outpatient procedures in our material). On the other side the radiation exposure can be raised as an issue, especially when we consider the operator's hands. However, the described technique and the use of dedicated tools can alleviate the problem. As a conclusion, real time CT fluoroscopy has given a new input and broadens the scope of clinical indications of CT-guided diagnostic and therapeutic procedures

  10. A review on diagnostic techniques for brucellosis | Kaltungo | African ...

    African Journals Online (AJOL)

    ... but has not been validated for standard laboratory use. This paper highlights useful samples and, especially the different conventional to more sophisticated molecular techniques for the diagnosis of brucellosis. Keywords: Brucellosis, diagnosis, techniques. African Journal of Biotechnology, Vol. 13(1), pp. 1-10, 1 January, ...

  11. Proposal to develop techniques using magneto-optic and electro-optic effects in optical fiber for CTR diagnostics

    International Nuclear Information System (INIS)

    Chandler, G.I.; Jahoda, F.C.

    1982-02-01

    We discuss the developing technology of measuring electric and magnetic fields with optical fibers using the Faraday and Kerr effects, magnetostriction, and Sagnac interferometry. We review the measurement of induced birefringence in the presence of natural birefringence. We propose the use of these effects in making measurements in the fusion research program, with ZT-40 as an example

  12. The application of DECnet TTT technique in beam diagnostical system of SSC central region

    International Nuclear Information System (INIS)

    Zhang Guixu; Huang Tuanhua

    1997-01-01

    The DECnet TTT technique and the real time network communication based on DECnet TTT are presented. Information can be transferred between console and diagnostical system via DECnet communication, so all kinds of operation can be done on console. The working computer of HIRFL console is VAX8350

  13. High sensitive diagnostic technique for virus gene using radioisotope. Development of PCR in situ hybridization and its application

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, Takuya; Sada, Tetsutaro; Terai, Masanori; Sato, Yuko; Kurata, Takeshi [National Inst. of Infectious Diseases, Tokyo (Japan); Yamaguchi, Kazuyoshi; Yanagisawa, Akio; Sakai, Yuzo

    1998-02-01

    An animal model, experimentally induced squamous cell carcinoma was produced in hamster mucosa to establish a carcinogenic system inducible by interaction of a virus and chemical(s). Human hydatid mole and cholioepithelioma were chosen as the target subjects. Several tumor cells and host cells were isolated under microscopy and DNA was extracted from these cells to indentify the respective origins (maternal, paternal or host origin). The base sequence of HLADRB region was analyzed by PCR using synthetic primer and the tissue localization was examined by PCR in situ hybridization. A PCR product of 82 bp was found in 15 of 17 samples and there were 2 samples in which the product was not detectable with the constructed primer and 6 samples were negative. While significant differences were not observed by in situ hybridization compared with the negative control. (M.N.)

  14. High sensitive diagnostic technique for virus gene using radioisotope. Development of PCR in situ hybridization and its application

    International Nuclear Information System (INIS)

    Iwasaki, Takuya; Sada, Tetsutaro; Terai, Masanori; Sato, Yuko; Kurata, Takeshi; Yamaguchi, Kazuyoshi; Yanagisawa, Akio; Sakai, Yuzo

    1998-01-01

    An animal model, experimentally induced squamous cell carcinoma was produced in hamster mucosa to establish a carcinogenic system inducible by interaction of a virus and chemical(s). Human hydatid mole and cholioepithelioma were chosen as the target subjects. Several tumor cells and host cells were isolated under microscopy and DNA was extracted from these cells to indentify the respective origins (maternal, paternal or host origin). The base sequence of HLADRB region was analyzed by PCR using synthetic primer and the tissue localization was examined by PCR in situ hybridization. A PCR product of 82 bp was found in 15 of 17 samples and there were 2 samples in which the product was not detectable with the constructed primer and 6 samples were negative. While significant differences were not observed by in situ hybridization compared with the negative control. (M.N.)

  15. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  16. The radiation protection optimisation in contrast X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Markovic, S.; Pavlovic, R.

    1995-01-01

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit α. (author) 3 figs., 10 refs

  17. The radiation protection optimisation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit {alpha}. (author) 3 figs., 10 refs.

  18. Rendezvous cannulation technique reduces post-ERCP pancreatitis: a prospective nationwide study of 12,718 ERCP procedures.

    Science.gov (United States)

    Swahn, Fredrik; Nilsson, Magnus; Arnelo, Urban; Löhr, Matthias; Persson, Gunnar; Enochsson, Lars

    2013-04-01

    The aim of this study was to investigate if intraoperative rendezvous cannulation reduces the risk of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) because there is no universal consensus on the optimal treatment of common bile duct stones. We performed a nationwide case-control study, nested within the cohort of ERCP procedures reported to the Swedish Registry for Gallstone Surgery and ERCP (GallRiks), between 2007 and 2009. Data were collected prospectively from a web-based registry of ERCP procedures that includes variables such as patient characteristics, indication, cannulation technique, diagnostic findings, therapeutic measures, and complications. The primary outcome was PEP. The registry included 12,718 ERCP procedures performed on patients without a history of previous ERCP. The risk of PEP when using the rendezvous technique compared with those who were cannulated by conventional means was reduced from 3.6 to 2.2% (odds ratio (OR) 0.5, 95% confidence interval 0.2-0.9, P=0.02). Although a significant reduction there are overall relatively few cases with PEP and the calculated numbers needed to treat to avoid one case of PEP is as high as 71. Other factors associated with increased risk of PEP were young age, prolonged procedure time, and elective ERCP. Rendezvous bile duct cannulation during ERCP reduces the risk of PEP from 3.6 to 2.2% compared with conventional biliary cannulation.

  19. Chromatographic quality control procedures for /sup 99m/Tc-diagnostic agents

    International Nuclear Information System (INIS)

    Marinelli, M.; Pozzato, R.; Garuti, P.; Zucchini, G.L.

    1986-01-01

    The purpose of this work was to experiment simple and rapid chromatographic systems, based on paper and thin-layer techniques, to test the radiochemical purity of some common /sup 99m/Tc diagnostic agents, and select those systems able to prevent the anomalies due to oxidation and artifact production. The agents were examined under conditions which usually bring about the above mentioned anomalies, then the results were compared with those obtained under controlled conditions. Quali- and quantitative detection of the activity present on the chromatograms was carried out using the equipment available in nuclear medicine departments

  20. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    International Nuclear Information System (INIS)

    Etard, Cecile; Aubert, Bernard; Mezzarobba, Myriam; Bernier, Marie-Odile

    2014-01-01

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  1. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    Energy Technology Data Exchange (ETDEWEB)

    Etard, Cecile; Aubert, Bernard [Institut de Radioprotection et de Surete Nucleaire, Medical Expertise Unit, Fontenay-aux-Roses (France); Mezzarobba, Myriam [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Bernier, Marie-Odile [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Institut de Radioprotection et de Surete Nucleaire, IRSN/PRP-HOM/SRBE/LEPID, Laboratoire d' Epidemiologie, Fontenay-aux-Roses (France)

    2014-12-15

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  2. Development of automatic extraction of the corpus callosum from magnetic resonance imaging of the head and examination of the early dementia objective diagnostic technique in feature analysis

    International Nuclear Information System (INIS)

    Kodama, Naoki; Kaneko, Tomoyuki

    2005-01-01

    We examined the objective diagnosis of dementia based on changes in the corpus callosum. We examined midsagittal head MR images of 17 early dementia patients (2 men and 15 women; mean age, 77.2±3.3 years) and 18 healthy elderly controls (2 men and 16 women; mean age, 73.8±6.5 years), 35 subjects altogether. First, the corpus callosum was automatically extracted from the MR images. Next, early dementia was compared with the healthy elderly individuals using 5 features of the straight-line methods, 5 features of the Run-Length Matrix, and 6 features of the Co-occurrence Matrix from the corpus callosum. Automatic extraction of the corpus callosum showed an accuracy rate of 84.1±3.7%. A statistically significant difference was found in 6 of the 16 features between early dementia patients and healthy elderly controls. Discriminant analysis using the 6 features demonstrated a sensitivity of 88.2% and specificity of 77.8%, with an overall accuracy of 82.9%. These results indicate that feature analysis based on changes in the corpus callosum can be used as an objective diagnostic technique for early dementia. (author)

  3. Calculation of radiation exposure in diagnostic radiology. Method and surveys

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Ramee, A.; Ezzeldin, K.; Guibert, J.L.

    1984-01-01

    A computerized method for evaluating the radiation exposure of the main target organs during various diagnostic radiologic procedures is described. This technique was used for educational purposes: study of exposure variations according to the technical modalities of a given procedure, and study of exposure variations according to various technical protocols (IVU, EGD barium study, etc.). This method was also used for studying exposure of patients during hospitalization in the Rennes Regional Hospital Center (France) in 1982, according to departments (urology, neurology, etc.). This method and results of these three studies are discussed [fr

  4. Action Research to Improve the Learning Space for Diagnostic Techniques

    Directory of Open Access Journals (Sweden)

    Ellen Ariel

    2015-08-01

    Full Text Available The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of “knowledge” and “understanding.” The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001, it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed.

  5. Action Research to Improve the Learning Space for Diagnostic Techniques.

    Science.gov (United States)

    Ariel, Ellen; Owens, Leigh

    2015-12-01

    The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of "knowledge" and "understanding." The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001), it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed. Journal of Microbiology & Biology Education.

  6. Multi Service Tactics, Techniques, and Procedures for Treatment of Chemical Warfare Agent Casualties and Conventional Military Chemical Injuries

    Science.gov (United States)

    2016-08-02

    and Education ATTN: DDJ 401 Chennault Circle Maxwell AFB, AL 36112-6004 DSN 493-7442; COMM (334) 953-7442 e-mail: lemayctr.ddj.wrkflw@us.af.mil viii...maintain an adequate nutritional status and to replace the loss of fluid and electrolytes. There may be a need to monitor the white blood count... hemoglobin , and platelets in severe systemic poisoning. If the white blood count decreases significantly, isolation and appropriate antibiotics may

  7. Procedures and techniques for the management of experimental fuels from research and test reactors. Proceedings of an advisory group meeting

    International Nuclear Information System (INIS)

    1999-04-01

    Almost all countries that have undertaken fuel development programs for power, research or military reactors have experimental and exotic fuels, either stored at the original research reactors where they have been tested or at some away-from-reactor storage facility. These spent fuel liabilities cannot follow the standard treatment recognized for modern power reactor fuels. They include experimental and exotic fuels ranging from liquids to coated spheres and in configurations ranging from full test assemblies to post irradiation examination specimens set in resin. This document contains an overview of the extent of the problem of managing experimental and exotic fuels from research and test reactors and an expert evaluation of the overall situation in countries which participated in the meeting

  8. Pulmonary carcinoma. Diagnostic and bronchoscopic treatment

    International Nuclear Information System (INIS)

    Caballero Duran, Hugo

    1997-01-01

    A historical recount of the bronchoscopy is made, from its beginnings 100 years ago, in a same way some techniques of diagnostic and treatment are mentioned, as the laser, fluorescence, cryotherapy, etc

  9. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  10. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension. Bildgebende nuklearmedizinische Diagnostik bei arterieller Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B M; Linss, G

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.).

  11. The EnVision++ system: a new immunohistochemical method for diagnostics and research. Critical comparison with the APAAP, ChemMate, CSA, LABC, and SABC techniques.

    Science.gov (United States)

    Sabattini, E; Bisgaard, K; Ascani, S; Poggi, S; Piccioli, M; Ceccarelli, C; Pieri, F; Fraternali-Orcioni, G; Pileri, S A

    1998-07-01

    To assess a newly developed immunohistochemical detection system, the EnVision++. A large series of differently processed normal and pathological samples and 53 relevant monoclonal antibodies were chosen. A chessboard titration assay was used to compare the results provided by the EnVision++ system with those of the APAAP, CSA, LSAB, SABC, and ChemMate methods, when applied either manually or in a TechMate 500 immunostainer. With the vast majority of the antibodies, EnVision++ allowed two- to fivefold higher dilutions than the APAAP, LSAB, SABC, and ChemMate techniques, the staining intensity and percentage of expected positive cells being the same. With some critical antibodies (such as the anti-CD5), it turned out to be superior in that it achieved consistently reproducible results with differently fixed or overfixed samples. Only the CSA method, which includes tyramide based enhancement, allowed the same dilutions as the EnVision++ system, and in one instance (with the anti-cyclin D1 antibody) represented the gold standard. The EnVision++ is an easy to use system, which avoids the possibility of disturbing endogenous biotin and lowers the cost per test by increasing the dilutions of the primary antibodies. Being a two step procedure, it reduces both the assay time and the workload.

  12. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  13. Towards the definition of Institutional diagnostic reference levels in paediatric interventional cardiology procedures in Greece.

    Science.gov (United States)

    Kottou, S; Kollaros, N; Plemmenos, C; Mastorakou, I; Apostolopoulou, S C; Tsapaki, V

    2018-02-01

    This study aimed to evaluate paediatric radiation doses in a dedicated cardiology hospital, with the objective of characterising patterns in dose variation. The ultimate purpose was to define Local (Institutional) Diagnostic Reference Levels (LDRLs) for different types of paediatric cardiac interventional procedures (IC), according to patient age. From a total of 710 cases performed during three consecutive years, by operators with more than 15 years of experience, the age was noted in only 477 IC procedures. The median values obtained for Fluoroscopy Time (FT), Number of Frames (N) and Kerma Area Product (P KA ) by age range were 5.8 min, 1322 and 2.0 Gy.cm 2 for definition of LDRLs presents challenges mainly due to the multiple clinical and technical factors affecting the outcome. On the other hand the lack of paediatric IC DRLs makes the identification of good practices more difficult. A consensus is needed on IC procedures nomenclature and grouping in order to allow a common assessment and comparison of doses. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Radiocardiography of minimal transit times: a useful diagnostic procedure

    International Nuclear Information System (INIS)

    Schicha, H.; Vyska, K.; Becker, V.; Feinendegen, L.E.; Duesseldorf Univ., F.R. Germany)

    1975-01-01

    Contrary to mean transit times, minimal transit times are the differences between arrival times of an indicator. Arrival times in various cardiac compartments can be easily measured with radioisotopes and fast gamma cameras permitting data processing. This paper summarizes data selected from more than 1500 measurements made so far on normal individuals and patients with valvular heart disease, myocardial insufficiency, digitalis effect, atrial fibrillation, hypothyroidism, hyperthyroidism, effort-syndrome and coronary artery disease. (author)

  15. Information matrix estimation procedures for cognitive diagnostic models.

    Science.gov (United States)

    Liu, Yanlou; Xin, Tao; Andersson, Björn; Tian, Wei

    2018-03-06

    Two new methods to estimate the asymptotic covariance matrix for marginal maximum likelihood estimation of cognitive diagnosis models (CDMs), the inverse of the observed information matrix and the sandwich-type estimator, are introduced. Unlike several previous covariance matrix estimators, the new methods take into account both the item and structural parameters. The relationships between the observed information matrix, the empirical cross-product information matrix, the sandwich-type covariance matrix and the two approaches proposed by de la Torre (2009, J. Educ. Behav. Stat., 34, 115) are discussed. Simulation results show that, for a correctly specified CDM and Q-matrix or with a slightly misspecified probability model, the observed information matrix and the sandwich-type covariance matrix exhibit good performance with respect to providing consistent standard errors of item parameter estimates. However, with substantial model misspecification only the sandwich-type covariance matrix exhibits robust performance. © 2018 The British Psychological Society.

  16. A Diagnostic Procedural Model for Identifying Real Educational Needs.

    Science.gov (United States)

    Londoner, Carroll

    This study evaluated educational problems and needs in the administrative management council of Bloomington Hospital, Bloomington, Indiana, in order to help produce a more effective task group within the hospital's institutional framework. Over a seven week period, the investigator observed department heads in their weekly conferences by means of…

  17. Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

    Science.gov (United States)

    Chang, Lienard A; Miller, Donald L; Lee, Choonsik; Melo, Dunstana R; Villoing, Daphnée; Drozdovitch, Vladimir; Thierry-Chef, Isabelle; Winters, Sarah J; Labrake, Michael; Myers, Charles F; Lim, Hyeyeun; Kitahara, Cari M; Linet, Martha S; Simon, Steven L

    2017-12-01

    This study summarizes and compares estimates of radiation absorbed dose to the thyroid gland for typical patients who underwent diagnostic radiology examinations in the years from 1930 to 2010. The authors estimated the thyroid dose for common examinations, including radiography, mammography, dental radiography, fluoroscopy, nuclear medicine, and computed tomography (CT). For the most part, a clear downward trend in thyroid dose over time for each procedure was observed. Historically, the highest thyroid doses came from the nuclear medicine thyroid scans in the 1960s (630 mGy), full-mouth series dental radiography (390 mGy) in the early years of the use of x rays in dentistry (1930s), and the barium swallow (esophagram) fluoroscopic exam also in the 1930s (140 mGy). Thyroid uptake nuclear medicine examinations and pancreatic scans also gave relatively high doses to the thyroid (64 mGy and 21 mGy, respectively, in the 1960s). In the 21st century, the highest thyroid doses still result from nuclear medicine thyroid scans (130 mGy), but high thyroid doses are also associated with chest/abdomen/pelvis CT scans (18 and 19 mGy for males and females, respectively). Thyroid doses from CT scans did not exhibit the same downward trend as observed for other examinations. The largest thyroid doses from conventional radiography came from cervical spine and skull examinations. Thyroid doses from mammography (which began in the 1960s) were generally a fraction of 1 mGy. The highest average doses to the thyroid from mammography were about 0.42 mGy, with modestly larger doses associated with imaging of breasts with large compressed thicknesses. Thyroid doses from dental radiographic procedures have decreased markedly throughout the decades, from an average of 390 mGy for a full-mouth series in the 1930s to an average of 0.31 mGy today. Upper GI series fluoroscopy examinations resulted in up to two orders of magnitude lower thyroid doses than the barium swallow. There are

  18. Robotic-assisted transperitoneal nephron-sparing surgery for small renal masses with associated surgical procedures: surgical technique and preliminary experience.

    Science.gov (United States)

    Ceccarelli, Graziano; Codacci-Pisanelli, Massimo; Patriti, Alberto; Ceribelli, Cecilia; Biancafarina, Alessia; Casciola, Luciano

    2013-09-01

    Small renal masses (T1a) are commonly diagnosed incidentally and can be treated with nephron-sparing surgery, preserving renal function and obtaining the same oncological results as radical surgery. Bigger lesions (T1b) may be treated in particular situations with a conservative approach too. We present our surgical technique based on robotic assistance for nephron-sparing surgery. We retrospectively analysed our series of 32 consecutive patients (two with 2 tumours and one with 4 bilateral tumours), for a total of 37 robotic nephron-sparing surgery (RNSS) performed between June 2008 and July 2012 by a single surgeon (G.C.). The technique differs depending on tumour site and size. The mean tumour size was 3.6 cm; according to the R.E.N.A.L. Nephrometry Score 9 procedures were considered of low, 14 of moderate and 9 of hight complexity with no conversion in open surgery. Vascular clamping was performed in 22 cases with a mean warm ischemia time of 21.5 min and the mean total procedure time was 149.2 min. Mean estimated blood loss was 187.1 ml. Mean hospital stay was 4.4 days. Histopathological evaluation confirmed 19 cases of clear cell carcinoma (all the multiple tumours were of this nature), 3 chromophobe tumours, 1 collecting duct carcinoma, 5 oncocytomas, 1 leiomyoma, 1 cavernous haemangioma and 2 benign cysts. Associated surgical procedures were performed in 10 cases (4 cholecystectomies, 3 important lyses of peritoneal adhesions, 1 adnexectomy, 1 right hemicolectomy, 1 hepatic resection). The mean follow-up time was 28.1 months ± 12.3 (range 6-54). Intraoperative complications were 3 cases of important bleeding not requiring conversion to open or transfusions. Regarding post-operative complications, there were a bowel occlusion, 1 pleural effusion, 2 pararenal hematoma, 3 asymptomatic DVT (deep vein thrombosis) and 1 transient increase in creatinine level. There was no evidence of tumour recurrence in the follow-up. RNSS is a safe and feasible technique

  19. Molecular characterization of the rDNA-ITS sequence and a PCR diagnostic technique for Pileolaria terebinthi, the cause of pistachio rust

    Directory of Open Access Journals (Sweden)

    Hossein ALAEI

    2013-01-01

    Full Text Available Eleven samples of the most important pistachio rust (caused by Pileolaria terebinthi (DC. Cast.,, which causes disease on Beneh (Pistacia atlantica Desf. subsp. mutica (Fisch. & Mey. Rech. F and Kasoor (Pistacia khinjuk Stocks., were collected from herbarium specimens and pistachio fields at the Pistachio Research Institute in Rafsanjan, Iran. The complete sequences of ribosomal DNA internal transcribed spacers ITS1 and ITS2 (rDNA ITS from the samples were determined and analysed. In general, very little rDNA ITS sequence variation was observed between rDNA ITS sequences of P. terebinthi samples. The length of the PCR fragments was 621 bp (for ITS1F-ITS4 and 1177 bp (for ITS1F-rust1, and consisted of 67 bp at the 3 ́ end of 18S rDNA, 93 bp of ITS1 region, 154 bp of 5.8S rDNA, 246 bp of the ITS2 region, 57 bp (for ITS1F-ITS4 and 613 bp (for ITS1F-rust1 at the 5 ́ end of the 28S rDNA. Restriction fragment length polymorphisms (RFLPs of the rDNA-ITS region were used to identify Pileolaria terebinthi. Three strong bands of 105, 134 and 381 bp and five bands of 105, 134, 200, 301 and 437 bp are observed for the fragment of “ITS1F-ITS4” and “ITS1F-rust1”, respectively. A PCR-RFLP diagnostic technique provided effective identification of the species by a unique pattern with the specific restriction enzyme XapI (ApoI.

  20. Computer Tomography: A Novel Diagnostic Technique used in Horses

    African Journals Online (AJOL)

    In Veterinary Medicine, Computer Tomography (CT scan) is used more often in dogs and cats than in large animals due to their small size and ease of manipulation. This paper, however, illustrates the use of the technique in horses. CT scan was used in the diagnosis of two conditions of the head and limbs, namely alveolar ...

  1. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  2. Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Pasciak, Alexander S. [Department of Radiology, The University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37922 (United States); Wagner, Louis K. [Department of Diagnostic and Interventional Imaging, The John P. and Katharine G. McGovern Medical School, Houston, Texas 77030 (United States)

    2016-07-15

    Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

  3. Elaboration and installation of technology of on-line diagnostics of important equipment damage as a procedure of NPP lifetime management

    International Nuclear Information System (INIS)

    Bakirov, M.; Povarov, V.

    2012-01-01

    In contrast to conventional approaches used for diagnostics (i.e. when inspection results are used as data for numerical calculative strength analysis) the specific feature of the new proposed approach consists in a fact that the approach is based on application of the 'inverse problem' principle. As regards to implementation of the proposed new approach, first of all a detailed numerical calculative finite-element model of the monitored equipment must be developed. Results of preliminary calculations allow to make reasonable selection of definite installation places and types of control sensors intended for more effective and precise work of the calculative model. As a rule, the control sensors are high-temperature strain gauges, temperature probes, pressure, acceleration and displacement sensors, as well as acoustic-emission and ultrasonic sensors used for monitoring of actual defectiveness kinetics in the zone of potential damaging. All the sensors work in the on-line mode during several years of operation, the optimal frequency of data records is selected, all recorded data after prompt processing are transferred to the finite-element calculative modulus for strength calculations of a monitored zone. Software for strength calculation must be based on an individual calculative code, since it should also work in the on-line mode. Comprehensible strength analysis in conjunction with obtained results of defectiveness kinetics monitoring allow not only to foresee the most unfavorable scenario resulting to damaging, but also to have a possibility for prompt analysis and elaboration of compensating measures allowing to reduce operational loadings. In the report the results of development and practical application of the new approach at NPPs and corresponding technology are presented. (author)

  4. Lost in Translation? Ethical Challenges of Implementing a New Diagnostic Procedure.

    Science.gov (United States)

    Schmitz, Dagmar

    2016-01-01

    Since cell-free DNA (cfDNA) fragments of placental origin can be isolated and analyzed from the blood of pregnant women. Applications of this finding have been developed and implemented in clinical care pathways worldwide at an unprecedented pace and manner. Implementation patterns, however, exhibit considerable insufficiencies. Different "motors" of implementation processes, like the market or various regulatory institutions, can be identified at a national level. Each "motor" entails characteristic ethical challenges which are exemplified impressively by a rising number of case reports.Empirical data demonstrate that there are significant "losses" in the respective translational processes, especially when the results from clinical research are to be translated into the clinical reality of NIPT (the so called "second roadblock" (T2)). These "losses" are perceived in the fields of knowledge transfer, professional standardization and ethical debate. Recommendations of professional organizations often fail to reach general practitioners. Blindsided by the new diagnostic procedure in their clinical practice, professionals in prenatal care express their insecurities with regard to its handling. Ethical debate appears to adhere to pre-existing (and partly already proven to be insufficient) normative frameworks for prenatal testing. While all of these deficits are typical for the implementation processes of many new molecular diagnostic procedures, especially in NIPT, they show a high variability between different nations.A critical assessment of the preferred strategy of implementation against the background of already existing national ethical frameworks is indispensable, if potential adverse effects are to be diminished. The described translational losses seem to be significantly reducible by granting the translational process in roadblock T2 more time.

  5. Journal of Special Operations Medicine. Training Supplement: Tactics, Techniques, and Procedures, Volume 8 Edition 4, Fall 2008

    Science.gov (United States)

    2008-01-01

    Anthrax, or Polonium 210 . Incidental events such as the postal letter to Senator Daschle that occurred in Washington, D.C. in October 2001 and the use of... Polonium 210 against Alexander Litvinenko in November 2006 show the potential of future insurgents’ willingness to conduct mass killings. The...authors as well (Navein et al., 2003). Hemostatic Agents No hemostatic agents had been approved by the Food and Drug Administration (FDA) and proven to

  6. Comparison Effect of Direct Trocar and Veress Needle Entry Techniques on Gut Functions after Laparoscopic Procedures: Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Taylan Şenol

    2016-12-01

    CONCLUSION: Direct or Veress needle entry methods were both safe to create pneumoperitoneum with similar postoperative gastrointestinal functions except for earlier first flatulence in Veress needle group while direct trocar entry was found to be associated with favorable postoperative blood count and shorter duration to obtain enough intraperitoneal pressure.

  7. Narrowing of the Diagnostic Gap of Acute Gastroenteritis in Children 0-6 Years of Age Using a Combination of Classical and Molecular Techniques, Delivers Challenges in Syndromic Approach Diagnostics.

    Science.gov (United States)

    Steyer, Andrej; Jevšnik, Monika; Petrovec, Miroslav; Pokorn, Marko; Grosek, Štefan; Fratnik Steyer, Adela; Šoba, Barbara; Uršič, Tina; Cerar Kišek, Tjaša; Kolenc, Marko; Trkov, Marija; Šparl, Petra; Duraisamy, Raja; Lipkin, W Ian; Terzić, Sara; Kolnik, Mojca; Mrvič, Tatjana; Kapoor, Amit; Strle, Franc

    2016-09-01

    Twenty-five percent to 50% of acute gastroenteritis (AGE) cases remain etiologically undiagnosed. Our main aim was to determine the most appropriate list of enteric pathogens to be included in the daily diagnostics scheme of AGE, ensuring the lowest possible diagnostic gap. Two hundred ninety seven children ≤6 years of age, admitted to hospital in Slovenia, October 2011 to October 2012, with AGE, and 88 ≤6 years old healthy children were included in the study. A broad spectrum of enteric pathogens was targeted with molecular methods, including 8 viruses, 6 bacteria and 2 parasites. At least one enteric pathogen was detected in 91.2% of cases with AGE and 27.3% of controls. Viruses were the most prevalent (82.5% and 15.9%), followed by bacteria (27.3% and 10.2%) and parasites (3.0% and 1.1%) in cases and controls, respectively. A high proportion (41.8%) of mixed infections was observed in the cases. For cases with undetermined etiology (8.8%), stool samples were analyzed with next generation sequencing, and a potential viral pathogen was detected in 17 additional samples (5.8%). Our study suggests that tests for rotaviruses, noroviruses genogroup II, adenoviruses 40/41, astroviruses, Campylobacter spp. and Salmonella sp. should be included in the initial diagnostic algorithm, which revealed the etiology in 83.5% of children tested. The use of molecular methods in diagnostics of gastroenteritis is preferable because of their high sensitivity, specificity, fast performance and the possibility of establishing the concentration of the target. The latter may be valuable for assessing the clinical significance of the detected enteric, particularly viral pathogens.

  8. SOFTWARE INSPECTION TECHNIQUE OF SCIENTIFIC AND ACADEMIC WORKS – PANACEA FOR THE PLAGIARISM OR A SPOT OF DIFFICULT PROCEDURE?

    Directory of Open Access Journals (Sweden)

    С. П. Ткаченко

    2017-10-01

    Full Text Available The use of software identifying text coincidences instruments provides an analysis of scientific and academic works for the evidence of plagiarism. Besides, the anti-plagiarism is not just a fight against illegal text borrowings as consequences of this phenomenon. It should be a comprehensive mechanism for dealing with both the consequences and the causes of the appearance of such a phenomenon. Such mechanism should include the implementation of the system of values that correspond to the principles of academic integrity, along with making total enquiries of all works on plagiarism. The exhaustive list of text borrowings, which is resultant, is the basis for expertsassessors decision-making in point of plagiarism presence. What is more, there should be no permissible standards of the plagiarism. All borrowings must being drawn up in accordance with the requirements. Therefore, the best result in the fight against plagiarism will achieved only by comprehensive approach – when the academic culture and the principles of academic integrity will be instilled ever since school, along with the check of all works for plagiarism.

  9. Generating consistent buildings: A semantic approach for integrating procedural techniques

    NARCIS (Netherlands)

    Tutenel, T.; Smelik, R.M.; Lopes, R.; Kraker, K.J. de; Bidarra, R.

    2011-01-01

    Computer games often take place in extensive virtual worlds, attractive for roaming and exploring. Unfortunately, current virtual cities can strongly hinder this kind of gameplay, since the buildings they feature typically have replicated interiors, or no interiors at all. Procedural content

  10. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding...... the basic technique involved, sampling, efficiency, and reproducibility. Various types of cancers, where stereologic grading of malignancy has been used, are reviewed and discussed with regard to the development of a new objective and reproducible basis for carrying out prognosis-related malignancy grading...

  11. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  12. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  13. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  14. The optimization of essential oils supercritical CO2 extraction from Lavandula hybrida through static-dynamic steps procedure and semi-continuous technique using response surface method

    Science.gov (United States)

    Kamali, Hossein; Aminimoghadamfarouj, Noushin; Golmakani, Ebrahim; Nematollahi, Alireza

    2015-01-01

    Aim: The aim of this study was to examine and evaluate crucial variables in essential oils extraction process from Lavandula hybrida through static-dynamic and semi-continuous techniques using response surface method. Materials and Methods: Essential oil components were extracted from Lavandula hybrida (Lavandin) flowers using supercritical carbon dioxide via static-dynamic steps (SDS) procedure, and semi-continuous (SC) technique. Results: Using response surface method the optimum extraction yield (4.768%) was obtained via SDS at 108.7 bar, 48.5°C, 120 min (static: 8×15), 24 min (dynamic: 8×3 min) in contrast to the 4.620% extraction yield for the SC at 111.6 bar, 49.2°C, 14 min (static), 121.1 min (dynamic). Conclusion: The results indicated that a substantial reduction (81.56%) solvent usage (kg CO2/g oil) is observed in the SDS method versus the conventional SC method. PMID:25598636

  15. Diagnostic analysis of vibration signals using adaptive digital filtering techniques

    Science.gov (United States)

    Jewell, R. E.; Jones, J. H.; Paul, J. E.

    1983-01-01

    Signal enhancement techniques are described using recently developed digital adaptive filtering equipment. Adaptive filtering concepts are not new; however, as a result of recent advances in microprocessor-based electronics, hardware has been developed that has stable characteristics and of a size exceeding 1000th order. Selected data processing examples are presented illustrating spectral line enhancement, adaptive noise cancellation, and transfer function estimation in the presence of corrupting noise.

  16. Rapid Analysis Procedures for Triglycerides and Fatty Acids as Pentyl and Phenethyl Esters for the Detection of Butter Adulteration Using Chromatographic Techniques

    Directory of Open Access Journals (Sweden)

    Daniele Naviglio

    2017-01-01

    Full Text Available This paper presents the development of three methods for quality control, fraud detection, and authentication of butter fat and other oils/fats using chromatographic techniques, with one method for triglycerides and two methods for fatty acids (FAs. The procedure for the analysis of triglycerides requires only dissolution of the sample in n-hexane and gas chromatography (GC analysis using a capillary column. The second method is based on the transesterification of triglycerides as pentyl esters in a single-step reaction using sodium pentanoate in pentanol. The reaction proceeds at room temperature and is similar to the potassium hydroxide-catalysed transesterification of triglycerides with methanol and even more similar to the sodium methoxide method