WorldWideScience

Sample records for determine umbilical catheter

  1. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  2. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978

  3. A Comparative Study of Blood Culture Sampling from Umbilical Catheter Line versus Peripheral Site

    Directory of Open Access Journals (Sweden)

    Abdolkarim Hamedi

    2010-08-01

    Full Text Available Neonatal sepsis is an important cause of death and morbidity in newborns and is diagnosed by isolation of organism in blood culture. In several reports,reliablity of blood cultures were done from umbi lical catheters,have been demonstrated. The objective of the present study was to determine,wether an inde welling umbilical catheter, could be an alternative site for blood culture. In a prospective study over 6 months during 2006,141 paired blood cultures from 134 infant,were done simultaneously from peripheral site and umbilical catheter (mostly U. V. C,during the first four days of life. Majority of these infants were preterm and admitted to NICU for special care. these infants had indwelling umbilical line and had indication of sepsis workup. A total of 141 pairs of blood cultures were obtained from 134 infants. In 16 infants blood culture pairs were positive for one organism in both peripheral vein and umbilical site. 71. 6% of total cultures (n=11pairs were negative in boths site. A total of 22 pairs were positive in one site only,with 5 positive from peripheral vein only and the other 17 from umblical site. Two pairs were positve in boths site with two different organism. In over all 16 infant (11%of blood were considered to be contaminated. Contamination rate were 2. 4% and 9. 2% for peripheral and umbilical catheter site. Contamination rate increased after 48 hours of age in umbilical catheter. The result showed that after 2 days contamination rate for blood culture taken from catheter line increased and specifity decreased. We recommended that blood culture via umblical catheter in first 2 days in sick neonates with indwelling catheter can be a alternate site of blood culture sampelling.

  4. Accuracy of chest radiography for positioning of the umbilical venous catheter

    Directory of Open Access Journals (Sweden)

    Adriana F.M. Guimarães

    2017-03-01

    Full Text Available Objectives: To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks – diaphragm, cardiac silhouette, and vertebral bodies – in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. Methods: This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Results: Of the 162 newborns assessed by echocardiography, only 44 (27.16% had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33% newborns, in the right atrium in 26 (16.05%, intra-hepatic in 37 (22.84%, and intra-aortic in-one newborn (0.62%. The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Conclusion: Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Resumo: Objetivos: Avaliar a acurácia da análise simultânea dos três marcos anatômicos radiográficos – diafragma, silhueta cardíaca e corpos vertebrais, na determinação da posição da extremidade

  5. Umbilical venous catheter retrieval in a 970 gm neonate by a novel technique

    Directory of Open Access Journals (Sweden)

    Arima Nigam

    2014-01-01

    Full Text Available Umbilical venous catheterization is a necessity for the advanced care of very low birth weight neonates. Even with utmost care, few complications cannot be avoided. Fractured and retained catheter fragments are one of them. Endoluminal retrieval of such a catheter is an uncommon and challenging procedure for the interventionist. The only alternative is an open exploration of these patients. Various techniques have been described for retrieval of such foreign bodies. We describe a novel technique for percutaneous retrieval of an embolized umbilical venous catheter from a very low birth weight neonate.

  6. Umbilical venous catheter malposition and errors in interpretation in newborns with Bochdalek hernia

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Patricia T.; Taylor, George A. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2015-07-15

    Neonates with congenital diaphragmatic hernia (CDH) often require placement of lines and tubes for supportive therapy. The resulting altered anatomy can result in diagnostic errors when interpreting the location of support lines and tubes such as UVCs (umbilical venous catheters). The purpose of this study was to evaluate the effect of CDH on UVC position and to evaluate the accuracy at which radiologists describe the position on chest radiographs. During a 5-year period, 406 chest radiographs performed within 7 days of birth in infants with congenital diaphragmatic hernia were identified and reviewed for the following data: presence of UVC, location of catheter tip (cavoatrial junction, intracardiac, intrahepatic or umbilical vein), and location of CDH (right or left). The radiologic report of the UVC tip location for each case was then reviewed individually to determine the adequacy of interpretation. Inadequate reports were classified as incorrect (the wrong location of the catheter tip was reported), no mention (the location of the catheter tip was in a suboptimal location but not mentioned), and not specified (the precise location of the catheter tip was not clearly stated in the report when the tip was in a suboptimal location). A total of 60 infants were identified as having CDH (56 on the left, 4 on the right). The most common location for an incorrectly placed UVC was the contralateral chest, accounting for 26.7% (16/60) of the infants, followed by an abdominal intrahepatic location (16.7%) and the umbilical vein (8.3%). Thirty percent (120/406) of the chest radiograph reports were found to be inadequate regarding the interpretation of the location of the catheter tip. The majority of the inadequate reports (48/406, 11.8%) did not specify when the catheter tip was in a suboptimal location. In 37 reports (9.1%), the location of the catheter tip was reported incorrectly, and no mention of the catheter location was made in 35 reports (8.6%). The location of

  7. Umbilical venous catheter malposition and errors in interpretation in newborns with Bochdalek hernia

    International Nuclear Information System (INIS)

    Chang, Patricia T.; Taylor, George A.

    2015-01-01

    Neonates with congenital diaphragmatic hernia (CDH) often require placement of lines and tubes for supportive therapy. The resulting altered anatomy can result in diagnostic errors when interpreting the location of support lines and tubes such as UVCs (umbilical venous catheters). The purpose of this study was to evaluate the effect of CDH on UVC position and to evaluate the accuracy at which radiologists describe the position on chest radiographs. During a 5-year period, 406 chest radiographs performed within 7 days of birth in infants with congenital diaphragmatic hernia were identified and reviewed for the following data: presence of UVC, location of catheter tip (cavoatrial junction, intracardiac, intrahepatic or umbilical vein), and location of CDH (right or left). The radiologic report of the UVC tip location for each case was then reviewed individually to determine the adequacy of interpretation. Inadequate reports were classified as incorrect (the wrong location of the catheter tip was reported), no mention (the location of the catheter tip was in a suboptimal location but not mentioned), and not specified (the precise location of the catheter tip was not clearly stated in the report when the tip was in a suboptimal location). A total of 60 infants were identified as having CDH (56 on the left, 4 on the right). The most common location for an incorrectly placed UVC was the contralateral chest, accounting for 26.7% (16/60) of the infants, followed by an abdominal intrahepatic location (16.7%) and the umbilical vein (8.3%). Thirty percent (120/406) of the chest radiograph reports were found to be inadequate regarding the interpretation of the location of the catheter tip. The majority of the inadequate reports (48/406, 11.8%) did not specify when the catheter tip was in a suboptimal location. In 37 reports (9.1%), the location of the catheter tip was reported incorrectly, and no mention of the catheter location was made in 35 reports (8.6%). The location of

  8. Multiple versus single lumen umbilical venous catheters for newborn infants.

    Science.gov (United States)

    Kabra, N S; Kumar, M; Shah, S S

    2005-07-20

    Multiple lumen umbilical venous catheters (ML-UVCs) instead of single lumen UVCs (SL-UVCs) may decrease the need for additional venous lines. Although it seems self-evident that ML-UVCs would reduce the need of additional venous lines, the rates of associated complications might be different. To compare the effectiveness and the safety of ML-UVCs versus SL-UVCs in terms of need of additional vascular access, rates of complications, morbidity and mortality in newborn infants. Randomized and quasi-randomized trials were identified by searching the MEDLINE (1966 - February 2005), EMBASE (1980- February 2005), CINAHL (1982 - February 2005), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2004) and Science Direct (subject area: medicine, journal and abstract database; 1967 to February 2005). Literature search also included a manual search of the abstracts of scientific meetings published in Pediatric Research (1990-2004). Additional citations were sought using references in articles retrieved from searches. Subject experts were contacted to identify the unpublished and ongoing studies. Randomized and quasi-randomized controlled clinical trials comparing safety and efficacy of multiple versus single lumen umbilical venous catheter in neonates (both term and preterm) who were in need of umbilical venous catheter insertion for vascular access in first four weeks of life. Each review author performed data extraction independently and differences were resolved by discussion. The following outcomes were determined: total number of additional peripheral intravenous lines per baby in first week and first four weeks of life, total number of additional percutaneously and surgically placed central venous lines per baby in first four weeks of life, and other safety and efficacy measures. The treatment effect estimators used were RR, RD, and WMD when appropriate along with their 95% CI. If RD was statistically significant, then number

  9. PRIMARY PERITONITIS WITH POCKETED ABSCESS INTRAPERITONEAL CAUSED BY UMBILICAL CATHETER INFECTION IN 22 DAYS OLD BABY

    Directory of Open Access Journals (Sweden)

    Ariputra -

    2015-07-01

    Full Text Available Primary peritonitis defined  as  a microbial  infection  of  the peritoneum  and peritoneal  fluid  in  theabsence of a gastrointestinal or visceral perforation. The source of infection is extra abdominal andmay arise  from  lymphatics  or blood  stream. One  of  the  infection  source  can be  extension  from anomphalitis  or  infected  umbilicus. Omphalitis  can  occur  due  to  complication  of Umbilical VeinCatheterization  (UVC. UVC  are used  to  provide  access  for  resuscitation,  frequent monitoring  ofblood, administration of fluids, blood and parenteral nutrition. We report a case of primary peritonitiswith  pocketed  intraperitoneal  abscess  caused  by umbilical  infection  in  22  days  old  baby. Patientpresent a clinical sign of peritonitis and severe omphalitis with history of using umbilical catheter. X-ray found a free fluid impression in the abdominal cavity. Patient undergo a laparotomy and pocketedintraperitoneal  abscess was  found  around  ligamentum  teres hepatis  area,  suspected  of  infectiouscomplications arising out from the use of umbilical catheter.  [MEDICINA 2014;45:193-198].

  10. Presence of air in the hepatic portal system in association with umbilical venous catheter malposition

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2014-01-01

    Full Text Available The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.

  11. Complications of umbilical vein catherisation. Case Report

    International Nuclear Information System (INIS)

    Bothur-Nowacka, J.; Czech-Kowalska, J.; Gruszfeld, D.; Nowakowska-Rysz, M.; Dobrzanska, A.; Kosciesza, A.; Polnik, D.

    2011-01-01

    Umbilical vein catheterization is a relatively easy procedure performed routinely on the neonate intensive care units. It provides a fast central vein access, but some complications have been described in the literature. Case Reports: We presented a case report of a premature infant (34 hbd) with extravasation of the parenteral nutrition and drugs to the liver after umbilical vein catheterization. Fever and increasing biochemical markers of infection were observed. USG revealed a heterogenic, well-limited space of 4 cm in diameter, located in the right lobe of the liver. CT excluded liver abscess. Considering neoplastic process or incorrect location of the catheter of the central vein, we performed liver biopsy. Results: Cytological and biochemical analysis of the aspirated fluid revealed extravasation of parenteral nutrition to the liver.Our case confirms the necessity of controlling a proper location of the central catheter right after its insertion and during hospitalization. (authors)

  12. Role of ultrasound for central catheter tip localization in neonates: a review of the current evidence.

    Science.gov (United States)

    Sharma, Deepak; Farahbakhsh, Nazanin; Tabatabaii, Seyyed Ahmad

    2018-02-15

    Central catheters are known as "life lines" in intensive care units and are used frequently in neonatal intensive care unit (NICU) for multiple indications. The central catheters used in NICU includes umbilical venous catheter (UVC), umbilical arterial catheter (UAC) and peripherally inserted central catheter (PICC) lines. The tip of these central lines needs to be in a correct position as malpositioned central line tips lead to many neonatal complications. Radiograph either abdomen or chest is the most widely used modality for locating the tip of the central catheter. There are many disadvantages of radiographic confirmation of tip position and recently ultrasound (USG)/echocardiography has been used for localization of catheter tip. USG provides real-time assessment of the tip position with other added advantages like no radiation exposure, need for minimal training for performing USG, minimal handling of the neonate, identification of migration of central lines and making repositioning of central lines under USG guidance. The present evidence supports the use of USG/Echo for localization of central catheter tip and USG has shown to have good sensitivity, specificity, positive predictive value and negative predictive value when compared with a radiograph. In this review, we discuss about the role of USG/Echo in the identification of tip of central catheters in neonatal care.

  13. Determination of the therapeutic potential of human umbilical cord ...

    African Journals Online (AJOL)

    This research was conducted to evaluate the therapeutic potential of human umbilical cord blood, by determining their effect on bacterial pathogens which included: Streptobacillus sp, Corynebacterium diphtheriae, Staphylococcus aureus, Salmonella typhimurium, and Escherichia coli. Cord blood samples were obtained ...

  14. Abnormal systemic venous connection possibly associated with a persistent right umbilical vein; a case report

    Directory of Open Access Journals (Sweden)

    Smevik Bjarne

    2004-04-01

    Full Text Available Abstract Background Abnormal venous connections involving a persistent right umbilical vein are rare. In a minority of cases the liver is entirely bypassed and the condition is associated with multiple congenital malformations. Case presentation The described case illustrates a systemic venous drainage that was severely abnormal in a newborn girl with a truncus arteriosus type II congenital heart defect. Injection of contrast medium through the umbilical vein catheter revealed a very peculiar venous connection that passed anterio-laterally through the right hemithorax before crossing in an oblique fashion towards the superior vena cava. Conclusions This venous drainage may be the result of a persistent right umbilical vein connecting with the superior vena cava.

  15. Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents.

    Science.gov (United States)

    Salerno, Sergio; Tudisca, Chiara; Murmura, Elena; Matranga, Domenica; La Tona, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio

    2017-05-01

    Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluated too. The number of correct characterizations was different due to the administration of the flow-chart. One hundred and six correct UVC assessments at the beginning switched to 196 after the administration of the flow-chart (p = 0.0001). The observed agreement among the twenty radiology residents was statistically significant, both before (kappa = 0.41, p < 0.001) and after (kappa = 0.37, p < 0.001) the flow-chart administration. The developed flow-chart demonstrated to be useful in increasing residents performance in UVC placement assessment.

  16. Delivery route determines the presence of immune complexes on umbilical cord erythrocytes.

    Science.gov (United States)

    de Lima, Andrés; Franco, Luis C; Sarmiento, Andrés; González, John M

    2017-11-01

    Umbilical cord blood offers a unique opportunity to study the basal level of immunoglobulin complexes. This study aims to determine the presence of immune complexes and complement deposition on erythrocytes from umbilical cord blood from normal, full-term pregnancies. In vitro pre-formed IgA, IgG, and IgM complexes were used as positive control for flow cytometry detection, and for C3d deposition. Blood samples (34) of umbilical cord blood taken from vaginal and cesarean deliveries were tested for the presence of immunoglobulin complexes. Fourteen samples from vaginal deliveries and 20 samples from cesarean deliveries were assessed. IgG and IgM complexes were detected on erythrocytes, whereas no IgA complexes or complement deposition was observed. Interestingly, the percentage of IgG complexes was higher on erythrocytes from vaginal delivery samples compared to those from cesarean deliveries. No other associations between immune complexes and other maternal or newborn variables were found. IgG and IgM complexes seem to be normally present on umbilical cord erythrocytes. Erythrocytes from vaginal deliveries have a higher percentage of IgG complexes present compared to that from cesarean deliveries. Since no C3d activity was detected, these complexes are non-pathological and should be part of the newborn's initial innate immune response.

  17. Exploring the umbilical and vaginal port during minimally invasive surgery.

    Science.gov (United States)

    Tinelli, Andrea; Tsin, Daniel A; Forgione, Antonello; Zorron, Ricardo; Dapri, Giovanni; Malvasi, Antonio; Benhidjeb, Tahar; Sparic, Radmila; Nezhat, Farr

    2017-09-01

    This article focuses on the anatomy, literature, and our own experiences in an effort to assist in the decision-making process of choosing between an umbilical or vaginal port. Umbilical access is more familiar to general surgeons; it is thicker than the transvaginal entry, and has more nerve endings and sensory innervations. This combination increases tissue damage and pain in the umbilical port site. The vaginal route requires prophylactic antibiotics, a Foley catheter, and a period of postoperative sexual abstinence. Removal of large specimens is a challenge in traditional laparoscopy. Recently, there has been increased interest in going beyond traditional laparoscopy by using the navel in single-incision and port-reduction techniques. The benefits for removal of surgical specimens by colpotomy are not new. There is increasing interest in techniques that use vaginotomy in multifunctional ways, as described under the names of culdolaparoscopy, minilaparoscopy-assisted natural orifice surgery, and natural orifice transluminal endoscopic surgery. Both the navel and the transvaginal accesses are safe and convenient to use in the hands of experienced laparoscopic surgeons. The umbilical site has been successfully used in laparoscopy as an entry and extraction port. Vaginal entry and extraction is associated with a lower risk of incisional hernias, less postoperative pain, and excellent cosmetic results.

  18. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  19. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    Science.gov (United States)

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.

  20. Current obstetrical practice and umbilical cord prolapse.

    Science.gov (United States)

    Usta, I M; Mercer, B M; Sibai, B M

    1999-01-01

    The aim of this study was to assess the contribution of current obstetrical practice to the occurrence and complications of umbilical cord prolapse. Maternal and neonatal charts of 87 pregnancies complicated by true umbilical cord prolapse during a 5-year period were reviewed. Twin gestation and noncephalic presentations were common features (14 and 41%, respectively). Eighty-nine percent (77) of infants were delivered by cesarean section of which 29% were classical and 88% were primary. The mean gestational age at delivery was 34.0 +/- 6.0 weeks, and the mean birth weight was 2318 +/- 1159 g. Obstetrical intervention preceded 41 (47%) cases (the obstetrical intervention group): amniotomy (9), scalp electrode application (4), intrauterine pressure catheter insertion (6), attempted external cephalic version (7), expectant management of preterm premature rupture of membranes (14), manual rotation of the fetal head (1), and amnioreduction (1). There were 11 perinatal deaths. Thirty-three percent of the infants (32) had a 5-min Apgar score < 7 and 34% had a cord pH < 7.20. Neonatal seizures, intracerebral hemorrhage, necrotizing enterocolitis, hyaline membrane disease, persistent fetal circulation, sepsis, assisted ventilation, and perinatal mortality were comparable in the "obstetrical intervention" and "no-intervention" groups. Most of the neonatal complications occurred in infants < 32 weeks' gestation. We conclude that obstetrical intervention contributes to 47% of umbilical cord prolapse cases; however, it does not increase the associated perinatal morbidity and mortality.

  1. Laparoscopic Placement of Peritoneal Dialysis Catheters in CAPD Patients: Complications and Survival

    Directory of Open Access Journals (Sweden)

    A Roueentan

    2008-06-01

    Full Text Available Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to introduce and assess a simplified laparoscopic method for the insertion of peritoneal dialysis catheters in continuous ambulatory peritoneal dialysis (CAPD patients.Methods: We enrolled 79 consecutive end-stage renal patients (46 men and 33 women with a mean age of 50 years (range: 19-83 years in this study. During the surgery, a 5-mm trocar was placed in the left upper quadrant for the optics and another 5-mm trocar was placed to the left of the umbilicus. Using the second trocar, a tunnel was formed 2 cm left of the umbilical plane for the insertion of a Tenckhoff catheter. Under direct vision, the catheter was advanced into the abdomen. The catheter was tested for patency. Catheters of all subjects were capped for two weeks before dialysis initiation.Results: The mean duration of the operation was 15 minutes. Ten patients died during the follow-up period, all due to other medical problems, and six patients underwent renal transplantation; however, no deaths or complications were observed during surgery. Early onset complications were seen in 12 patients (15.1%. The most frequent late-onset medical and mechanical complications were peritonitis (6.3% and hernia (3.7%. During a follow-up period of four years, removal of the catheter was required in two patients as a result of peritonitis.Conclusion: We obtained a low complication rate and a high catheter survival rate with this laparoscopic insertion of the Tenckhoff catheter. We believe future experience will encourage the use of this safe, simple and quick procedure.

  2. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  3. Umbilical Hernia

    Science.gov (United States)

    ... Prompt diagnosis and treatment can help prevent complications. Causes During pregnancy, the umbilical cord passes through a small opening ... abdominal pressure can cause an umbilical hernia. Possible causes in adults include: ... pregnancies Fluid in the abdominal cavity (ascites) Previous abdominal ...

  4. Determinants of brain-derived neurotrophic factor (BDNF) in umbilical cord and maternal serum.

    Science.gov (United States)

    Flöck, A; Weber, S K; Ferrari, N; Fietz, C; Graf, C; Fimmers, R; Gembruch, U; Merz, W M

    2016-01-01

    Brain-derived neurotrophic factor (BDNF) plays a fundamental role in brain development; additionally, it is involved in various aspects of cerebral function, including neurodegenerative and psychiatric diseases. Involvement of BDNF in parturition has not been investigated. The aim of our study was to analyze determinants of umbilical cord BDNF (UC-BDNF) concentrations of healthy, term newborns and their respective mothers. This cross-sectional prospective study was performed at a tertiary referral center. Maternal venous blood samples were taken on admission to labor ward; newborn venous blood samples were drawn from the umbilical cord (UC), before delivery of the placenta. Analysis was performed with a commercially available immunoassay. Univariate analyses and stepwise multivariate regression models were applied. 120 patients were recruited. UC-BDNF levels were lower than maternal serum concentrations (median 641 ng/mL, IQR 506 vs. median 780 ng/mL, IQR 602). Correlation between UC- and maternal BDNF was low (R=0.251, p=0.01). In univariate analysis, mode of delivery (MoD), gestational age (GA), body mass index at delivery, and gestational diabetes were determinants of UC-BDNF (MoD and smoking for maternal BDNF, respectively). Stepwise multivariate regression analysis revealed a model with MoD and GA as determinants for UC-BDNF (MoD for maternal BDNF). MoD and GA at delivery are determinants of circulating BDNF in the mother and newborn. We hypothesize that BDNF, like other neuroendocrine factors, is involved in the neuroendocrine cascade of delivery. Timing and mode of delivery may exert BDNF-induced effects on the cerebral function of newborns and their mothers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Umbilical cord blood glucose levels in full-term newborns

    Directory of Open Access Journals (Sweden)

    A. L. Karpova

    2014-01-01

    Full Text Available The purpose of the investigation was to determine the umbilical cord venous blood level of glucose in full-term newborns and its relationship to the mode of delivery. The investigation included 102 full-term newborn infants, including 33 and 69 babies born via cesar-ean and vaginal delivery, respectively. Umbilical cord serum glucose levels were determined by the glucose oxidase test using a Sap-phire-400 biochemical analyzer. In healthy full-term newborns, the mean umbilical cord blood glucose levels were 4,29±0,88 mmol/1 (minimum, 2,9 mmol/1 and maximum, 5,9 mmol/1. In the babies born via cesarean delivery, the umbilical cord blood concentration of glucose was ascertained to be significantly lower than in those born vaginally (3,84+0,71 mmol/1 versus 4,51+0,87 mmol/1; /><0,0001. Abdominal delivery can be apparently considered to be a risk factor for hypoglycemia in neonatal infants.

  6. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  7. Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

    Science.gov (United States)

    Ainsworth, S B; Clerihew, L; McGuire, W

    2007-07-18

    Parenteral nutrition for neonates may be delivered via a short peripheral cannula or a central venous catheter. The latter may either be inserted via the umbilicus or percutaneously. Because of the complications associated with umbilical venous catheter use, many neonatal units prefer to use percutaneously inserted catheters following the initial stabilisation period. The method of parenteral nutrition delivery may affect nutrient input and consequently growth and development. Although potentially more difficult to place, percutaneous central venous catheters may be more stable than peripheral cannulae, and need less frequent replacement. These delivery methods may also be associated with different risks of adverse events, including acquired systemic infection and extravasation injury. To determine the effect of infusion via a percutaneous central venous catheter versus a peripheral cannula on nutrient input, growth and development, and complications including systemic infection, or extravasation injuries in newborn infants who require parenteral nutrition. The standard search strategy of the Cochrane Neonatal Review Group was used. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1, 2007), MEDLINE (1966 - February 2007), EMBASE (1980 - February 2007), conference proceedings, and previous reviews. Randomised controlled trials that compared the effect of delivering parenteral nutrition via a percutaneous central venous catheter versus a peripheral cannulae in neonates. Data were extracted the data using the standard methods of the Cochrane Neonatal Review Group, with separate evaluation of trial quality and data extraction by each author, and synthesis of data using relative risk, risk difference and mean difference. Four trials eligible for inclusion were found. These trials recruited a total of 368 infants and reported a number of different outcomes. One study showed that the use of a percutaneous

  8. Evolution of umbilicals in Brazil: optimizing deepwater umbilical applications with thermoplastic hoses and steel tubes

    Energy Technology Data Exchange (ETDEWEB)

    Guerra Neto, Mauro Del [DuPont do Brasil S.A., Barueri, SP (Brazil)

    2008-07-01

    Subsea umbilicals in the past 25 years have evolved in parallel with other subsea oil and gas technologies, as the search for hydrocarbons needed to drive the global economy has led offshore exploration and development companies to seek reserves ever-farther from shore in water thousands of meters deep. Relegated to little more than afterthought status before the push into deep water, modern umbilicals have now become crucial components linking deep water producers to their subsea wells, controlling subsea production systems through hydraulic and electrical power and injecting production chemicals for corrosion-, scale-, and hydrate-inhibition at subsea well heads. Particularly in subsea developments involving several deep water wells, umbilicals today are integral to both the production-system design and the chosen operating strategy. Failure of an umbilical linking a subsea well head in deep water to a host production facility can inflict severe economic consequences upon an operator by impairing production operations or halting production altogether. The additional cost of repairing or replacing a failed umbilical can run into the millions of dollars. As offshore oil and gas production has moved into ever-deeper water, umbilical manufacturers have begun introducing new stronger materials to handle the inherently higher pressures and temperatures. Today, two types of construction are used for fluid conduits in umbilical systems deployed in deep water: thermoplastic hoses and steel tubes. Steel tubes are generally more expensive than thermoplastic hoses, relatively stiff and considered to have high tensile strength, while thermoplastic hoses are extremely flexible and exhibit lower tensile strength. This lower tensile strength of the hoses may be compensated by including steel wire armoring in the umbilical. This also provides the added benefits of additional mechanical protection compared with the equivalent unarmored steel-tubes umbilicals. When either

  9. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  10. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  12. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  13. Morphological aspects of buffaloes (Bubalus bubalis umbilical cord Aspectos Morfológicos do cordão umbilical de búfalos (Bubalus bubalis

    Directory of Open Access Journals (Sweden)

    Guilherme J. Ferreira

    2009-10-01

    Full Text Available Buffalo is an important livestock resource, with a great participation in agricultural systems, providing milk, meat, and work power. Umbilical cord is responsible for maternal-fetal nutrients exchange during pregnancy, and its alterations can compromise the fetal development. We investigated ten pregnant uteruses collected from cross-bread buffaloes in different stages of gestation. Pregnancy and fetal age was determined by measuring the apex sacral length and development period was calculated by previously published formula. Umbilical cords were measured for length determination. Umbilical cord vascular net and anastomosis were observed by injection of Neoprene latex. Histological sections of the umbilical cord were studied after stain with HE, picrossirius, toluidine blue, orceine, and PAS reaction. Buffaloes' umbilical cord was formed by two central arteries, an allantois duct and two peripheral veins. The artery wall was composed by large quantity of collagen, elastic fibers, fibroblasts and large number of vasa vasorum. The allantois duct was located between the arteries and presented a great number of small nourishing vessels. Small nourishing vessels should be carefully considered to avoid to be mistaken to the arterials and veins vasa vasorum. Medium length of umbilical cord from buffalos was 11.8cm (minimum of 6.8cm and maximum of 17.4cm.Búfalo é uma importante fonte de recurso nos rebanhos animais, apresentando uma grande participação na agropecuária, provendo leite, carne e força de trabalho. O Cordão umbilical é responsável pela troca de nutrientes materno-fetais durante a gestação, e suas alterações podem comprometer o desenvolvimento fetal. Nós investigamos dez úteros gravídicos de búfalos de raças cruzadas em fases diferentes de gestação. O período de gestação e a idade fetal foram determinados pelo comprimento ápice sacral, aplicando fórmulas previamente estabelecidas. Posteriormente mediu-se o

  14. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    Science.gov (United States)

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  15. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  17. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  18. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  19. Determine Multiple Elements Simultaneously in the Sera of Umbilical Cord Blood Samples-a Very Simple Method.

    Science.gov (United States)

    Liang, Chunmei; Li, Zhijuan; Xia, Xun; Wang, Qunan; Tao, Ruiwen; Tao, Yiran; Xiang, Haiyun; Tong, Shilu; Tao, Fangbiao

    2017-05-01

    Analyzing the concentrations of heavy metals in the sera of umbilical cord blood samples can provide useful information about prenatal exposure to environmental agents. An analytical method based on ICP-MS to simultaneously determine multiple elements in umbilical cord blood samples was developed for assessing the in utero exposure to metallic and metalloid elements. The method only required as little as 100 μL of serum diluted 1:25 for direct analysis. Matrix-matched protocol was used to eliminate mass matrix interference and kinetic energy discrimination mode was used to eliminate the polyatomic ion interference. The assay was completed on average within 4 min with the detection limits ranging from 0.0002 to 44.4 μg/L for all the targeted elements. The detection rates for most of elements were 100 % other than cadmium (Cd), lead (Pb), and mercury (Hg). The testing results of the certified reference materials were ideal. The method is simple and sensitive, so it is suitable for the monitoring of large quantities of samples.

  20. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  1. Heart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.

    Science.gov (United States)

    Ursem, N T; Struijk, P C; Hop, W C; Clark, E B; Keller, B B; Wladimiroff, J W

    1998-11-01

    1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consented to participate in a cross-sectional study design. Doppler ultrasound recordings were made from the free-floating loop of the umbilical cord.3. Umbilical artery peak systolic and time-averaged velocity increased at 10-20 weeks, whereas fetal heart rate decreased at 10-15 weeks of gestation and plateaued thereafter. Umbilical artery peak systolic velocity variability and fetal heart rate variability increased at 10-20 and 15-20 weeks respectively.4. The inverse relationship between umbilical artery flow velocity and fetal heart rate at 10-15 weeks of gestation suggests that the Frank-Starling mechanism regulates cardiovascular control as early as the late first and early second trimesters of pregnancy. A different underlying mechanism is suggested for the observed variability profiles in heart rate and umbilical artery peak systolic velocity. It is speculated that heart rate variability is mediated by maturation of the parasympathetic nervous system, whereas peak systolic velocity variability reflects the activation of a haemodynamic feedback mechanism.

  2. Randomised Controlled Trial to determine the appropriate time to initiate peritoneal dialysis after insertion of catheter to minimise complications (Timely PD study

    Directory of Open Access Journals (Sweden)

    Fassett Robert G

    2010-06-01

    Full Text Available Abstract Background The most appropriate time to initiate dialysis after surgical insertion of Tenckhoff catheters is not clear in the literature. There is the possibility of peritoneal dialysis (PD complications such as leakage and infection if dialysis is started too soon after insertion. However, much morbidity and expense could be saved by reducing dependency on haemodialysis (HD by earlier initiation of PD post catheter insertion. Previous studies are observational and mostly compare immediate with delayed use. The primary objective is to determine the safest and shortest time interval between surgical placement of a Tenckhoff catheter and starting PD. Methods/Design This is a randomised controlled trial of patients who will start PD after insertion of Tenckhoff catheter at Royal Brisbane and Women's Hospital (RBWH or Rockhampton Base Hospital (RBH who meet the inclusion criteria. Patients will be stratified by site and diabetic status. The patients will be randomised to one of three treatment groups. Group 1 will start PD one week after Tenckhoff catheter insertion, group 2 at two weeks and group 3 at four weeks. Nurses and physicians will be blinded to the randomised allocation. The primary end point is the complication rate (leaks and infection after initiation of PD. Discussion The study will determine the most appropriate time to initiate PD after placement of a Tenckhoff catheter. Trial Registration ACTRN12610000076077

  3. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  4. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  5. Calcified aneurysm of the abdominal aorta 12 years after umbilical artery catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Blondiaux, Eleonore; Miquel, Julie [Rouen University Hospital Charles Nicolle, Department of Radiology, Rouen (France); Thomas, Pascale; Watelet, Jacques [Rouen University Hospital Charles Nicolle, Department of Vascular Surgery, Rouen (France); Laloum, Denis [Caen University Hospital, Pediatric Intensive Care Unit, Department of Neonatal Medicine, Caen (France); Dacher, Jean-Nicolas [Rouen University Hospital Charles Nicolle, Department of Radiology, Rouen (France); UFR Medecine et Pharmacie, Laboratoire Quant-If, Rouen Cedex 01 (France)

    2008-02-15

    We report a 12-year-old boy who presented with abdominal pain and who was found to have an aneurysm of the abdominal aorta (AAA). The patient was born from a quadruplet pregnancy induced by in vitro fertilization. Postnatal transient respiratory distress required assisted ventilation that had been monitored by two consecutive umbilical arterial catheters (UAC). AAA is a rare condition in childhood. Infection and/or trauma are known to be the most frequent causes. Most of the reported cases have occurred in children in whom a UAC had been placed during the neonatal period. In this patient the delay between UAC placement and diagnosis was considerable. At the time of this report the patient had remained well during a follow-up of 8 years after treatment. (orig.)

  6. Calcified aneurysm of the abdominal aorta 12 years after umbilical artery catheterization

    International Nuclear Information System (INIS)

    Blondiaux, Eleonore; Miquel, Julie; Thomas, Pascale; Watelet, Jacques; Laloum, Denis; Dacher, Jean-Nicolas

    2008-01-01

    We report a 12-year-old boy who presented with abdominal pain and who was found to have an aneurysm of the abdominal aorta (AAA). The patient was born from a quadruplet pregnancy induced by in vitro fertilization. Postnatal transient respiratory distress required assisted ventilation that had been monitored by two consecutive umbilical arterial catheters (UAC). AAA is a rare condition in childhood. Infection and/or trauma are known to be the most frequent causes. Most of the reported cases have occurred in children in whom a UAC had been placed during the neonatal period. In this patient the delay between UAC placement and diagnosis was considerable. At the time of this report the patient had remained well during a follow-up of 8 years after treatment. (orig.)

  7. Umbilical scarring in hatchling American alligators

    Science.gov (United States)

    Wiebe, J.J.; Sepulveda, M.S.; Buckland, J.E.; Anderson, S.R.; Gross, T.S.

    2004-01-01

    Umbilical scarring is the presence of excess scar tissue deposited between abdominal dermal layers at the site of yolk sac absorption in hatchling American alligators (Alligator mississippiensis). The presence of this dermal condition plays a key evaluatory role in the overall quality and subsequent value for various commercial leather products. Despite the prevalent nature of this condition, currently the industry has no standardized protocols for its quantification. The objectives of this study were to examine the relationship between hatchling weight and age and incidence of umbilical scarring and to develop a quantifiable and reproducible technique to measure this dermal condition in hatchling American alligators. Thirty eggs from each of nine clutches were incubated in two separate incubators at different facilities and hatchling umbilical scarring was measured at 2 and 10 days of age using digital calipers. Umbilical area was calculated by multiplying umbilical length times umbilical width. There was a significant effect of both age and clutch on umbilical area (overall decline of 64%) by 10 days post-hatch. However, only five of the nine clutches utilized expressed a noticeable decline in the size of this dermal condition (range 67-74%). We had hypothesized that larger hatchlings would have larger umbilical areas and a slower rate of improvement in this condition during the first few days post-hatch. The differences in umbilical area and percent decline with age across clutches, however, were not associated with differences in initial hatchling weights. Within clutches and time periods, hatchling weight had no significant effect on the size and/or rate of decline of this condition. ?? 2004 Published by Elsevier B.V.

  8. Incarcerated umbilical hernia in children.

    Science.gov (United States)

    Chirdan, L B; Uba, A F; Kidmas, A T

    2006-02-01

    Umbilical hernia is common in children. Complications from umbilical hernias are thought to be rare and the natural history is spontaneous closure within 5 years. A retrospective analysis was performed of the medical records of a series of 23 children who presented with incarcerated umbilical hernias at our institution over an 8-year period. Fifty-two children with umbilical hernias were seen in the hospital over the period. Twenty-three (44.2%) had incarceration. Seventeen (32.7%) had acute incarceration while 6 (11.5%) had recurrent incarceration. There were 16 girls and 7 boys. The ages of the children with acute incarceration ranged from 3 weeks to 12 years (median 4 years), while the ages of those with recurrent incarceration ranged from 3-15 years (median 8.5 years). Incarceration occurred in hernias of more than 1.5 cm in diameter (in those whose defect size was measured). Twenty-one children (15 with acute and all six with recurrent incarceration) underwent repair of the umbilical hernia using standard methods. The parents of two children with acute incarceration declined surgery after spontaneous reduction of the hernia in one and taxis in the other. One boy had gangrenous bowel containing Meckel's diverticulum inside the sac, for which bowel resection with end-to-end anastomosis was done. Operation led to disappearance of pain in all 6 children with recurrent incarceration. Superficial wound infection occurred in one child. There was no mortality. Incarcerated umbilical hernia is not as uncommon as thought. Active observation of children with umbilical hernia is necessary to prevent morbidity from incarceration.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  12. Catheter-Related Sepsis Due to Rhodotorula glutinis

    Science.gov (United States)

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  13. Poorly understood and often miscategorized congenital umbilical cord hernia: an alternative repair method.

    Science.gov (United States)

    İnce, E; Temiz, A; Ezer, S S; Gezer, H Ö; Hiçsönmez, A

    2017-06-01

    Umbilical cord hernia is poorly understood and often miscategorized as "omphalocele minor". Careless clamping of the cord leads to iatrogenic gut injury in the situation of umbilical cord hernia. This study aimed to determine the characteristics and outcomes of umbilical cord hernias. We also highlight an alternative repair method for umbilical cord hernias. We recorded 15 cases of umbilical cord hernias over 10 years. The patients' data were retrospectively reviewed, and preoperative preparation of the newborn, gestational age, birth weight, other associated malformations, surgical technique used, enteral nutrition, and length of hospitalization were recorded. This study included 15 neonates with umbilical cord hernias. The mean gestational age at the time of referral was 38.2 ± 2.1 umbilical cord hernia, the body folds develop normally and form the umbilical ring. The double purse-string technique is easy to apply and produces satisfactory cosmetic results in neonates with umbilical cord hernias.

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  15. Umbilical hernia repair - series (image)

    Science.gov (United States)

    ... treatment. The indications for umbilical hernia repair include: incarcerated (strangulated) umbilical hernia defects not spontaneously closed by 4 to 5 years of age children under 2 with very large defects unacceptable to ...

  16. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  17. Pregnancy Complications: Umbilical Cord Abnormalities

    Science.gov (United States)

    ... Umbilical cord abnormalities Umbilical cord abnormalities Now playing: E-mail to a friend Please fill in all fields. ... blood supply) to the baby. The two arteries transport waste from the baby to the placenta (where ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  19. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  20. Anatomical and procedural determinants of catheter-based renal denervation

    NARCIS (Netherlands)

    Ewen, Sebastian; Ukena, Christian; Lüscher, Thomas Felix; Bergmann, Martin; Blankestijn, Peter J; Blessing, Erwin; Cremers, Bodo; Dörr, Oliver; Hering, Dagmara; Kaiser, Lukas; Nef, Holger; Noory, Elias; Schlaich, Markus; Sharif, Faisal; Sudano, Isabella; Vogel, Britta; Voskuil, Michiel; Zeller, Thomas; Tzafriri, Abraham R; Edelman, Elazer R; Lauder, Lucas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2016-01-01

    BACKGROUND/PURPOSE: Catheter-based renal sympathetic denervation (RDN) can reduce blood pressure (BP) and sympathetic activity in certain patients with uncontrolled hypertension. Less is known about the impact of renal anatomy and procedural parameters on subsequent BP response. METHODS/MATERIALS: A

  1. Determination of adrenomedullin and endothelin in cord blood and their expressions in umbilical cord vessel of patients with pregnancy-induced hypertension

    International Nuclear Information System (INIS)

    Ruan Lihong; Zhu Fengquan; Wang Xing; Pan Yu

    2004-01-01

    Objective: To investigate the role of adrenomedullin (ADM) and endothelin-1 (ET-1) in the pathogenesis of pregnancy-induced hypertension (PIH). Methods: The plasma concentrations of ADM in human umbilical vein of PIH patients (n=30) and normal late trimester pregnancy women (n=12) were measured by radioimmunoassay. The expressions of ADM and ET-1 in umbilical cord vessel of PIH patients (n=40) and normal late trimester pregnancy women (n=12) were detected by immunohistochemistry (SABC). Results: 1) The plasma concentration of ADM in human umbilical vein of PIH patients was significantly higher than that of normal late trimester pregnancy women (P 0.05). 2) The expression of ADM was found in endothelium and smooth muscle cell of umbilical cord vessel, and it increased with the serious degree of PIH. The expression of ET-1 was only found in endothelium of umbilical cord vessel, and it decreased with the serious degree of PIH. Conclusion: The changes of ADM and ET-1 in umbilical cord plasma and vessel may related to regulation of fetoplacental circulation in PIH

  2. Incarcerated umbilical cord hernia containing the gallbladder

    Directory of Open Access Journals (Sweden)

    Ann M. Kulungowski

    2017-06-01

    Full Text Available A 16 day-old boy infant with an umbilical mass underwent operative exploration of the umbilicus. The mass proved to be a gallbladder incarcerated in a hernia of the umbilical cord. Distinguishing an omphalocele from an umbilical cord hernia is not obvious and can be arbitrary. Morphologically, the two terms both describe congenital abdominal wall defects covered by a membrane, typically containing abdominal organs. Subtle differences and clinical features between omphalocele and umbilical cord hernia are highlighted in this report.

  3. Umbilical Cable Recovery Load Analysis

    Institute of Scientific and Technical Information of China (English)

    YAN Shu-wang; JIA Zhao-lin; FENG Xiao-wei; LI Shi-tao

    2013-01-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field.The severe ocean environment makes great challenges to umbilical maintenance and repair work.Damaged umbilical is usually recovered for the regular operation of the offshore production system.Analysis on cables in essence is a two-point boundary problem.The tension load at the mudline must be known first,and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation.The recovery analysis also involves umbilicalsoil interaction and becomes more complicated.Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed.The analysis results provide a theoretical reference for offshore on-deck operation.

  4. Religious perspectives on umbilical cord blood banking.

    Science.gov (United States)

    Jordens, Christopher F C; O'Connor, Michelle A C; Kerridge, Ian H; Stewart, Cameron; Cameron, Andrew; Keown, Damien; Lawrence, Rabbi Jeremy; McGarrity, Andrew; Sachedina, Abdulaziz; Tobin, Bernadette

    2012-03-01

    Umbilical cord blood is a valuable source of haematopoietic stem cells. There is little information about whether religious affiliations have any bearing on attitudes to and decisions about its collection, donation and storage. The authors provided information about umbilical cord blood banking to expert commentators from six major world religions (Catholicism, Anglicanism, Islam, Judaism, Hinduism and Buddhism) and asked them to address a specific set of questions in a commentary. The commentaries suggest there is considerable support for umbilical cord blood banking in these religions. Four commentaries provide moral grounds for favouring public donation over private storage. None attach any particular religious significance to the umbilical cord or to the blood within it, nor place restrictions on the ethnicity or religion of donors and recipients. Views on ownership of umbilical cord blood vary. The authors offer a series of general points for those who seek a better understanding of religious perspectives on umbilical cord blood banking.

  5. Significance of determination of insulin, glucagon and cortisol levels in maternal and umbilical cord blood

    International Nuclear Information System (INIS)

    Li Chun; Li Runhao; Yan Songqin

    2006-01-01

    Objective: To determine the insulin (INS), glucagon (GLUC) and cortisol (COR) levels in maternal and umbilical cord blood for appropriate gestational age (AGA) neonates and to explore the correlation among the body weight of AGA neonates and body mass index (BMI) of pregnant woman, serum INS, GLUC, COR levels of maternal as well as umbilical cord blood. Methods: Neonates fell into lower-than-normal body weight group ( group A n=9) and higher-than-normal body weight group (group B n =17); serum INS, GLUC and COR levels were measured with radioimmunoassay in 26 pairs of mothers and neonates with uneventful delivery. Results: The body weight of neonate was positively correlated with the BMI of pregnant women, the BMI of pregnant women in group B were significantly higher than those in group A (P<0.05). The maternal serum GLUC and COR levels were significantly higher than those in cord blood (P<0.05, P<0.01). Cord blood COR contents in group B were significantly higher than those in group A (P<0.01), the reverse was true for GLUC (P<0.05). Conclusion: Fetal growth is closely related to the BMI of pregnant women and serum INS, GLUC and COR levels indicating that maternal nutritional condition would directly affect the birth weight of the neonates. (authors)

  6. Reference interval determination of hemoglobin fractions in umbilical cord and placental blood by capillary electrophoresis.

    Science.gov (United States)

    Bó, Suzane Dal; de Oliveira Lemos, Fabiane Kreutz; Pedrazzani, Fabiane Spagnol; Cagliari, Cláudia Rosa; Scotti, Luciana

    2016-04-01

    Umbilical cord and placental blood (UCPB) is a rich source of hematopoietic stem cells widely used to treat diseases that did not have effective treatments until recently. Umbilical cord and placental blood banks (UCPBBs) are needed to be created to store UCPB. UCPB is collected immediately after birth, processed, and frozen until infusion. Detection of abnormal hemoglobins is one of UCPB screening tests available. The objective of the present study was to determine the reference interval for HbA, HbF, and HbA2 in UCPB using capillary electrophoresis. Methods: Observational retrospective study of UCPB samples undergoing hemoglobin electrophoresis was performed between April 2012 and May 2013. We analyzed 273 UCPB samples. All cords met the criteria of BrasilCORD. We found 19.9% (10.5–36.7%) for HbA, 80.1% (62.7–89.4%) for HbF, and 0.1% (0.0–0.6%) for HbA2. Data were expressed as median (P2.5–P97.5). Establishing specific reference intervals is the best option for most tests because such ranges reflect the status of the population in which the tests will be applied. The use of appropriate reference intervals ensures that clinical labs provide reliable information, thus enabling clinicians to correctly interpret results and choose the best approach for the target population.

  7. A neonate with an intact congenital umbilical appendix: an alternative theory on the etiology of the appendico-umbilical fistula.

    NARCIS (Netherlands)

    Fuijkschot, J.; Wijnen, R.M.H.; Gerrits, G.P.J.M.; Dubois, S.V.; Rieu, P.N.M.A.

    2006-01-01

    Neonatal umbilical anomalies usually represent remains of the vitelline duct or the allantois. We describe a case of an umbilical appendix in a neonate. The vermiform appendix was found to be positioned in the umbilical cord. In a brief literature review we found eight other reports concerning

  8. Relationship between newborn Acid-Base status and umbilical cord morphology

    Directory of Open Access Journals (Sweden)

    Marssosi V

    2001-06-01

    Full Text Available ess the relationship between umbilical cord blood gases at birth and morphology of umbilical cord, in a prospective study of 200 consecutive term delivery, we investigated the relationship between umbilical cord morphology characteristics (umbilical crd length, number of vascular coil, coiling index and color of amniotic fluid and umbilical vessel blood gases. Statistically significant linear correlation was found between umblicial venous PH and the umbilical cord length (r=0.39, 95% CI 0.25, 0.53, P<0.03, umber of vascular coils (r=0.45 95% CI 0.31-0.59 P<0.012, and coiling index (r=0.34, 95% CI 0.12-0.48, P<0.04, and also negative linear correlation was found between umbilical venous partial pressure of carbon dioxide & of coli (r=0.3, 95% CI –0.44, -0.16 P<0.03. No relation was found between umbilical cord indices and meconium staining of amniotic fluid.Placental weight also correlated with umbilical cord length (r=0.17, 95% CI 0.03-0.31, P<0.03, but not with umbilical cord coils or coiling index.Umbilical venous pH is related to umbilical cord morphology but umbilical venous PCO2 was only related to the number of coils and umbilicat artery pH wa only related to the number of coils and not related to length or coiling index of umbilical cord morphology. The morphology of umbilical cord can affect maternal-fetal gas exchange

  9. Cost-effectiveness of private umbilical cord blood banking.

    Science.gov (United States)

    Kaimal, Anjali J; Smith, Catherine C; Laros, Russell K; Caughey, Aaron B; Cheng, Yvonne W

    2009-10-01

    To investigate the cost-effectiveness of private umbilical cord blood banking. A decision-analytic model was designed comparing private umbilical cord blood banking with no umbilical cord blood banking. Baseline assumptions included a cost of $3,620 for umbilical cord blood banking and storage for 20 years, a 0.04% chance of requiring an autologous stem cell transplant, a 0.07% chance of a sibling requiring an allogenic stem cell transplant, and a 50% reduction in risk of graft-versus-host disease if a sibling uses banked umbilical cord blood. Private cord blood banking is not cost-effective because it cost an additional $1,374,246 per life-year gained. In sensitivity analysis, if the cost of umbilical cord blood banking is less than $262 or the likelihood of a child needing a stem cell transplant is greater than 1 in 110, private umbilical cord blood banking becomes cost-effective. Currently, private umbilical cord blood banking is cost-effective only for children with a very high likelihood of needing a stem cell transplant. Patients considering private blood banking should be informed of the remote likelihood that a unit will be used for a child or another family member. III.

  10. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    Science.gov (United States)

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  11. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  12. Evidence-based pathology: umbilical cord coiling.

    Science.gov (United States)

    Khong, T Y

    2010-12-01

    The generation of a pathology test result must be based on criteria that are proven to be acceptably reproducible and clinically relevant to be evidence-based. This review de-constructs the umbilical cord coiling index to illustrate how it can stray from being evidence-based. Publications related to umbilical cord coiling were retrieved and analysed with regard to how the umbilical coiling index was calculated, abnormal coiling was defined and reference ranges were constructed. Errors and other influences that can occur with the measurement of the length of the umbilical cord or of the number of coils can compromise the generation of the coiling index. Definitions of abnormal coiling are not consistent in the literature. Reference ranges defining hypocoiling or hypercoiling have not taken those potential errors or the possible effect of gestational age into account. Even the way numerical test results in anatomical pathology are generated, as illustrated by the umbilical coiling index, warrants a critical analysis into its evidence base to ensure that they are reproducible or free from errors.

  13. Serum immunoglobulin from Nellore cattle produced by in vitro fertilization and treated for umbilical diseases

    Directory of Open Access Journals (Sweden)

    Celso Antonio Rodrigues

    Full Text Available ABSTRACT: The aim of this study was to measure serum immunoglobulin concentrations of Nellore cattle produced by in vitro fertilization (IVF with umbilical diseases and to evaluate surgical excision as a method of treatment. Sixteen cattle with ages ranging from 1 to 15 months, males and females, affected by umbilical diseases were enrolled in the study. Blood samples were collected for cell counts and the determination of immunoglobulin concentrations by electrophoresis and zinc sulphate turbidimetry (ZST. Four calves were presented with umbilical herniation, two with an umbilical herniation associated with a persistent urachus, two with an umbilical herniation with a persistent urachus and omphaloarteritis, three with an umbilical herniation and an urachal diverticulum, three with a persistent urachus, one with an urachal diverticulum, and one with omphalitis. The blood cell counts pre- and post-surgical revealed differences in cell volume and the number of leukocytes. The immunoglobulin values measured by electrophoresis values were below normal in most animals, whereas the ZST showed normal levels in most of them. Most of the calves affected by umbilical diseases and produced by IVF presented hypoglobulinaemia. Correlations between umbilical diseases, failure of passive transfer of immunity and IVF could not be demonstrated.

  14. Endometriose umbilical sem cirurgia pélvica prévia Umbilical endometriosis without previous pelvic surgery

    Directory of Open Access Journals (Sweden)

    Bruno Ramalho de Carvalho

    2008-04-01

    Full Text Available OBJETIVO: apresentar série de casos de endometriose na cicatriz umbilical, em pacientes no menacme, sem cirurgias pélvicas prévias. MÉTODOS: foram incluídas no estudo quatro pacientes com idade entre 33 e 43 anos, com queixa de sangramento umbilical associado ou não a dor pélvica, com evolução de dois meses a quatro anos. A ultra-sonografia da parede abdominal foi utilizada para o diagnóstico, procedendo-se à exérese cirúrgica das lesões sugestivas de endometriose umbilical e confirmação anatomopatológica. RESULTADOS: as avaliações ultra-sonográficas das quatro pacientes evidenciaram imagens umbilicais hipoecogênicas compatíveis com a hipótese diagnóstica de endometriose e, assim, todas elas foram encaminhadas para exérese cirúrgica da lesão. A dosagem do marcador sérico CA-125 foi realizada em três das quatro pacientes, com níveis dentro da normalidade, variando de 6,8 a 10,1 U/mL. A concomitância de endometriose pélvica apenas foi confirmada em uma paciente. Durante o seguimento de um ano, as pacientes não apresentaram recidiva dos sintomas nem das lesões. CONCLUSÕES: a endometriose umbilical é uma entidade nosológica rara, mas que deve ser sempre lembrada quando da presença de nodulações ou sangramento umbilicais, ainda que não exista relato de cirurgia pélvica prévia com manipulação endometrial. Seu tratamento cirúrgico é, em geral, suficiente para a remissão total da lesão e dos sintomas.PURPOSE: to present a series of cases of umbilical endometriosis in patients in reproductive age, with no previous pelvic surgery. METHODS: four patients aged between 33 and 43 years were included in the study. They all presented umbilical bleeding associated or not with pelvic pain, and medical history varied from two months to four years. Abdominal wall ultrasound was performed for diagnosis support before surgical excision of the umbilical lesions, and histological examination was also performed. RESULTS

  15. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  16. Transplante de sangue de cordão umbilical - SCU Umbilical cord blood transplantation

    Directory of Open Access Journals (Sweden)

    Celso A. Rodrigues

    2010-05-01

    Full Text Available A frequente utilização de sangue de cordão umbilical - SCU como fonte de células- tronco hematopoéticas - CTH, tanto em crianças, como em adultos, que não dispõem de doador na família, tem levado ao estabelecimento da padronização de critérios em sua seleção, objetivando a obtenção de melhores resultados. A escolha da unidade de SCU deve basear-se no número total de células nucleadas e no número de diferenças de antígenos leucocitários humanos (HLA. Diante de uma unidade com celularidade mínima, deve-se considerar a possibilidade da utilização de duplo cordão. Frente a mais de uma unidade com características semelhantes, a realização da contagem de células CD34 e da compatibilidade ABO, assim como a qualidade e a rapidez para obtenção da unidade, podem definir a escolha.The frequent use of umbilical cord blood as the source of hematopoietic stem cells, both in children and adults who do not have related donors, has led to the establishment of a better standardization of selection criteria aiming at improving the results. The choice of the umbilical cord blood unit should be based on the total number of nucleated cells and the number of differences in the human leukocyte antigen (HLA system. When a unit has minimal cellularity, the use of a double cord blood transplant should be considered. When two or more units have similar characteristics, the choice may be determined by the CD34 count, ABO compatibility and the quality and speed to obtain the unit.

  17. Absence of robust ischemic preconditioning by five 1-minute total umbilical cord occlusions in fetal sheep.

    NARCIS (Netherlands)

    Lotgering, F.K.; Bishai, J.M.; Struijk, P.C.; Blood, A.B.; Hunter, C.J.; Oberg, K.C.; Power, G.G.; Longo, L.D.

    2004-01-01

    OBJECTIVE: To determine to what extent a series of five 1-minute total umbilical cord occlusions, intended to induce ischemic preconditioning (IP), affects the physiologic responses to a 10-minute total umbilical cord occlusion (damaging insult [DI]) 1 hour later and provides cardio- and

  18. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  19. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  20. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  1. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  2. A comparison between two types of central venous catheters in the prevention of catheter-related infections: the importance of performing all the relevant cultures

    NARCIS (Netherlands)

    van Vliet, J.; Leusink, J.A.; de Jongh, B.M.; de Boer, A.

    2001-01-01

    Objective: to determine the efficacy of double-lumen central venous catheters coated with chlorhexidine and silver-sulfadiazine in reducing the incidence of catheter-related infections. Design: a randomized controlled trial. Setting: medical-surgical intensive care unit of a 600-bed teaching

  3. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Background Peritoneal dialysis catheter (PDC) failure still remains a common clinical problem in pediatric patients despite advancements in catheter placement and dialysis techniques. Our aim was to determine the risk factors that may lead to PDC failure, especially those factors that could be potentially modified to ...

  4. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  15. Cardiac tamponade in an infant during contrast infusion through central venous catheter for chest computed tomography; Tamponamento cardiaco durante infusao de contraste em acesso venoso central para realizacao de tomografia computadorizada do torax em lactente

    Energy Technology Data Exchange (ETDEWEB)

    Daud, Danilo Felix; Campos, Marcos Menezes Freitas de; Fleury Neto, Augusto de Padua [Hospital Geral de Palmas, TO (Brazil)

    2013-11-15

    Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein. (author)

  16. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  19. Intrauterine thrombosis of umbilical artery - case report

    Directory of Open Access Journals (Sweden)

    Gustavo Henrique de Oliveira

    Full Text Available ABSTRACT: CONTEXT: Umbilical cord thrombosis is related to greater fetal and perinatal morbidity and mortality. It is usually associated with umbilical cord abnormalities that lead to mechanical compression with consequent vascular ectasia. Its correct diagnosis and clinical management remains a challenge that has not yet been resolved. CASE REPORT: This study reports a case of umbilical artery thrombosis that occurred in the second half of a pregnancy. The umbilical cord was long, thin and overly twisted and the fetus presented severe intrauterine growth restriction. The clinical and histopathological findings from this case are described. CONCLUSIONS: This case report emphasizes the difficulty in diagnosing and clinically managing abnormalities of intrauterine life with a high chance of perinatal complications.

  20. Doppler ultrasound scan during normal gestation: umbilical circulation

    International Nuclear Information System (INIS)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J.

    2002-01-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs

  1. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  2. Culture-dependent and -independent investigations of microbial diversity on urinary catheters

    DEFF Research Database (Denmark)

    Xu, Yijuan; Moser, Claus Ernst; Abu Al-Soud, Waleed

    2012-01-01

    Catheter-associated urinary tract infection is caused by bacteria, which ascend the catheter along its external or internal surface to the bladder and subsequently develop into biofilms on the catheter and uroepithelium. Antibiotic-treated bacteria and bacteria residing in biofilm can be difficult...... to culture. In this study we used culture-based and 16S rRNA gene-based culture-independent methods (fingerprinting, cloning, and pyrosequencing) to determine the microbial diversity of biofilms on 24 urinary catheters. Most of the patients were catheterized for...

  3. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  6. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  7. Radioimmunological determination of 5a-pregnane-3,20-dione and progesterone in arterial and venous blood from the umbilical cord

    International Nuclear Information System (INIS)

    Tannich, E.

    1985-01-01

    Radioimmunological investigations of arterial and venous blood from the umbilical cord for 5a-DHP and progesterone were carried out in 60 newly delivered infants using 3 H as a tracer substance. The following findings were revealed: 1) The correlation between progesterone and 5a-DHP was better in the venous blood than in the arterial blood from the umbilical cord and the concentrations measured for the two hormones were higher in the vein. 2) Both the umbilical vein and artery showed more elevated hormone levels in male infants as compared to female infants. 3) The duration of gestation, the concentration of hydrogen ions in the fetal plasma and various other maternal and fetal factors have an influence on the height of the 5a-DHP and progesterone levels in the umbilical blood. This was also concluded from the fact that the (arterial and venous) hormone concentrations measured in infants from primiparae were higher than those in infants from multiparae. The metabolisation of 5a-DHP varies between the sexes, which does not hold true for progosterone. (TRV) [de

  8. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  9. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  10. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  11. Acceptance criteria for reprocessed AcuNav catheters: comparison between functionality testing and clinical image assessment.

    Science.gov (United States)

    Bank, Alan J; Berry, James M; Wilson, Robert F; Lester, Bruce R

    2009-03-01

    The AcuNav-catheter is a vector-phased array ultrasound catheter that has shown great utility for both diagnosis and electrophysiological interventions. To test the feasibility of limited catheter reuse and to ensure that reprocessed catheters would produce acceptable clinical images, the present study compared the 2-D and Doppler image quality, as determined by clinical assessment, with the catheter's functional status as determined by the FirstCall 2000 transducer tester. Reprocessed catheters from four functional categories, two acceptable and two unacceptable, were used to collect images, 2-D and Doppler, from a porcine heart. The images were blinded and then rated by clinical evaluation. The study found that catheter images from all functional categories were found to be clinically acceptable except for those from the lowest unacceptable category. In addition, examination of tip deflection characteristics showed no significant difference between new and reprocessed catheters. We conclude that reprocessed AcuNav catheters that pass functional tests are able to produce clinical images, 2-D and Doppler, which are equivalent to their new counterparts.

  12. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  13. Rare Abdominal Wall Malformation: Case Report of Umbilical Cord Hernia

    Directory of Open Access Journals (Sweden)

    Andro Gliha

    2018-02-01

    Full Text Available The umbilical cord hernia is the rarest form of abdominal wall malformations, anatomically completely different from gastroschisis and omphalocele. It occurs due to the permanent physiological evisceration of abdominal organs into umbilical celom and persistence of a patent umbilical ring. The umbilical cord hernia is often mistaken for omphalocele and called “small omphalocele”. Here we present a case of a female newborn with umbilical cord hernia treated in our Hospital. After preoperative examinations surgery was done on the second day of life. The abdominal wall was closed without tension. The aim of this article is to present the importance of the proper diagnose of these three entities and to stimulate academic community for the answer, is this umbilical cord hernia or small omphalocele.

  14. Rare Abdominal Wall Malformation: Case Report of Umbilical Cord Hernia.

    Science.gov (United States)

    Gliha, Andro; Car, Andrija; Višnjić, Stjepan; Zupancic, Bozidar; Kondza, Karmen; Petracic, Ivan

    The umbilical cord hernia is the rarest form of abdominal wall malformations, anatomically completely different from gastroschisis and omphalocele. It occurs due to the permanent physiological evisceration of abdominal organs into umbilical celom and persistence of a patent umbilical ring. The umbilical cord hernia is often mistaken for omphalocele and called "small omphalocele". Here we present a case of a female newborn with umbilical cord hernia treated in our Hospital. After preoperative examinations surgery was done on the second day of life. The abdominal wall was closed without tension. The aim of this article is to present the importance of the proper diagnose of these three entities and to stimulate academic community for the answer, is this umbilical cord hernia or small omphalocele.

  15. Neurologic condition of healthy term infants at 18 months : Positive association with venous umbilical DHA status and negative association with umbilical trans-fatty acids

    NARCIS (Netherlands)

    Bouwstra, Hylco; Dijck-Brouwer, Janneke; Decsi, Tamas; Boehm, Guenther; Boersma, E. Rudy; Muskiet, Frits A. J.; Hadders-Algra, Mijna

    Prenatal long-chain polyunsaturated fatty acids (LCPUFAs) and trans-fatty acids may affect neurodevelopment. In healthy term children, we determined relationships between relative fatty acid contents of umbilical arteries and veins and neurodevelopment at 18 mo. The study comprised a mixed group of

  16. Correlation between placenta and umbilical cord morphplogy and ...

    African Journals Online (AJOL)

    Context: The ability of the fetus to grow and thrive in-utero depends on a number of factors of which the placenta is a contributor. The umbilical cord is an essential organ connecting the fetus to the placenta and a healthy placenta is essential for good perinatal outcome. Objectives: The study aims at determining the ...

  17. Primary umbilical endometriosis: a case report | Muluka | Journal of ...

    African Journals Online (AJOL)

    Umbilical endometriosis is a rare presentation especially in the absence of prior pelvic surgery. This report presents a rare case of symptomatic primary umbilical endometriosis in a 28 year old female who presented with a 2 year history of umbilical mass associated with cyclical bleeding at the time of her menses.

  18. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  19. Types of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).

    Science.gov (United States)

    Pickard, R; Lam, T; Maclennan, G; Starr, K; Kilonzo, M; McPherson, G; Gillies, K; McDonald, A; Walton, K; Buckley, B; Glazener, C; Boachie, C; Burr, J; Norrie, J; Vale, L; Grant, A; N'dow, J

    2012-11-01

    Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. Do antimicrobial catheters reduce the rate of symptomatic urinary tract infection (UTI) during short-term hospital use and is their use cost-effective for the UK NHS? A pragmatic multicentre UK randomised controlled trial comparing three catheters as they would be used in the UK NHS: antimicrobial-impregnated (nitrofurazone) and antiseptic-coated (silver alloy) catheters with the standard polytetrafluoroethylene (PTFE)-coated catheters. Economic evaluation used a decision model populated with data from the trial. Sensitivity analysis was used to explore uncertainty. Relevant clinical departments in 24 NHS hospitals throughout the UK. Adults requiring temporary urethral catheterisation for a period of between 1 and 14 days as part of their care, predominantly as a result of elective surgery. Eligible participants were randomised 1 : 1 : 1 to one of three types of urethral catheter in order to make the following pragmatic comparisons: nitrofurazone-impregnated silicone catheter compared with standard PTFE-coated latex catheter; and silver alloy-coated hydrogel latex catheter compared with standard PTFE-coated latex catheter. The primary outcome for clinical effectiveness was the incidence of UTI at any time up to 6 weeks post randomisation. This was defined as any symptom reported during catheterisation, up to 3 days or 1 or 2 weeks post catheter removal or 6 weeks post randomisation combined with a prescription of antibiotics, at any of these times, for presumed symptomatic UTI. The primary economic

  20. Totally Contact Umbilical Lightlike Hypersurfaces of Indefinite -Manifolds

    Directory of Open Access Journals (Sweden)

    Rachna Rani

    2013-01-01

    Full Text Available We study totally contact umbilical lightlike hypersurfaces of indefinite -manifolds and prove the nonexistence of totally contact umbilical lightlike hypersurface in indefinite -space form.

  1. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  2. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  3. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    Science.gov (United States)

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  4. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    Science.gov (United States)

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have 45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  5. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  6. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  7. Reference Values for Umbilical Cord Blood Gases of Newborns Delivered by Elective Cesarean Section.

    Science.gov (United States)

    Manomayangkul, Kattiya; Siriussawakul, Arunotai; Nimmannit, Akarin; Yuyen, Thassayu; Ngerncham, Sopapan; Reesukumal, Kanit

    2016-05-01

    Umbilical cord blood gas values are better indicators of perinatal asphyxia than Apgar scores. Many studies have reported normal ranges of umbilical cord blood gases, which vary greatly due to many factors. This study aimed to establish the reference values of umbilical cord blood gases of normal cesarean newborns in a university hospital setting. Blood samples from the umbilical artery and vein were collected from 160 newborns delivered by elective cesarean section. The indications for caesarean section were not due to fetal distress, intrauterine growth retardation, or non-reassuring fetal heart rate. The blood samples were collected immediately after birth in the operating room and then sent for blood-gas analysis. The blood-gas values were statistically analyzed and reported. The cord blood collected from 160 newborns was analyzed in this study. Seventy-eight percent (115) of the parturients were hypotensive before delivery. All Apgar scores at one and five minutes after delivery were at least 7. The calculated reference range of the umbilical arterial pH was 7.18-7.42, of pO₂was 6.43-29.43 mmHg, of pCO₂was 33.44-66.56 mmHg, and of HCO₃was 15.60-30.70 mEq/L. The reference range obtained for the umbilical venous pH was 7.28-7.44,for pO₂was 13.97-37.13 mmHg, for pCO₂was 30.70-57.0 mmHg, and for HCO₃was 18.50-29.90 mEq/L. The study determined normal reference values as a result of umbilical cord blood gas analyses.

  8. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  9. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  11. Correlation between the umbilical artery flow ultrasound parameters of intrauterine fetal distress and fetal ischemic hypoxic damage

    Directory of Open Access Journals (Sweden)

    Hai-Ying Gu

    2017-08-01

    Full Text Available Objective: To study the correlation between the umbilical artery flow ultrasound parameters of intrauterine fetal distress and fetal ischemic hypoxic damage. Methods: A total of 158 puerperae who gave birth in our hospital between July 2016 and June 2017 were selected and divided into the intrauterine distress group (Apgar<7 points and normal pregnancy group (Apgar≥7 points according to the neonatal Apgar score, the umbilical artery flow ultrasound parameters at 24-30 weeks, 31-36 weeks and 37-41 weeks of gestation were determined, and the umbilical arterial blood gas parameters and oxidative stress molecule levels were determined. Results: At 24-30 weeks, 31-36 weeks and 37-41 weeks of gestation, umbilical arterial RI, PI and S/D of intrauterine distress group were significantly higher than those of normal pregnancy group; umbilical arterial pH and PaO2 of intrauterine distress group were significantly lower than those of normal pregnancy group and negatively correlated with RI, PI and S/D while PaCO2 and lactic acid levels were significantly higher than those of normal pregnancy group and positively correlated with RI, PI and S/D; SOD, GSH-px and CAT levels in umbilical artery of intrauterine distress group were significantly lower than those of normal pregnancy group and negatively correlated with RI, PI and S/D while MDA and 8-OHdG levels were significantly higher than those of normal pregnancy group and positively correlated with RI, PI and S/D. Conclusion: Umbilical artery flow ultrasound characteristics of intrauterine fetal distress are characterized by the increased resistance and decreased blood flow and are correlated with the degree of fetal hypoxia and oxidative stress.

  12. Infectious Complications of Radiologically Inserted Hickman Catheters in Patients with Hematologic Disorders

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Overhagen, Hans van; Wielenga, Jenne; Marie, Siem de; Nouwen, Jan; Ridder, Marie A.J. de; Lameris, Johan S.

    1998-01-01

    Purpose: To assess the incidence of infections and its influence on the survival of radiologically inserted Hickman catheters (HCs) in patients with hematologic disorders and to determine factors associated with premature HC removal. Methods: Survival and complications of 175 HCs in 115 patients were studied retrospectively. To describe the data the Kaplan-Meier method and the log-rank test were used, using the date of HC removal due to HC-related infection as endpoint. A stratified Cox regression model was used to determine explanatory factors. Results: Seventy (40%) HCs were removed prematurely because of proven or probable HC-related infections. The incidence of infection leading to HC removal was 4.78 per 1000 catheter-days for proven HC infections. Univariate analysis revealed that acute myeloid leukemia, acute lymphocytic leukemia, or treatment for these diseases, gender, each subsequent catheter in the same patient and insertion site increased the risk of premature removal of the catheter due to infection. Conclusion: Infection is a major problem in patients with HCs. Unfortunately, the factors associated with increased infection rates that were found in this study cannot be influenced. Further studies are necessary to determine the role of environmental conditions in a radiology suite in relation to the risk of developing a catheter-related infection

  13. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  14. In Vitro Urethra Model to Characterize The Frictional Properties of Urinary Catheters

    DEFF Research Database (Denmark)

    Røn, Troels; Lee, Seunghwan

    2016-01-01

    conformal sliding contacts with the catheter and high relevance to clinical catherization. With the proposed urethra model assembled in texture analyzer, the lubricity of catheters lubricated in different modes was tested. In comparison with conventional pin-on-disk tribometry, the coefficients of friction......, frictional properties of tubular devices such as catheters, endoscopes, and angioplasty balloons are particularly challenging to characterize because of non-standard shape and contact configuration. In this study, we propose that fabrication of in vitro urethra model with castable elastomers can provide...... of sliding contacts with the urethra model with unlubricated and lubricated catheters were determined. Impact of the improved bio-relevance of friction testing methods on the evaluation of various catheter materials and surface modification methods is discussed in detail....

  15. [Pathophysiological changes of umbilical vessels in intrauterine growth restriction].

    Science.gov (United States)

    Jakó, Mária; Surányi, Andrea; Kaiser, László; Domokos, Dóra; Gáspár, Róbert; Bártfai, György

    2014-12-14

    The prevalence of intrauterine growth restriction is 4-5000/100,000 births, and they give the majority of perinatal morbidity. The aim of the authors was to compare the pathomorphologic data and vasoreactivity of umbilical vessels and placenta of small for date newborns to that of the normal pregnancies. Samples of the umbilical cord and placenta were divided into case and control groups. Two 10 cm long segments were cut of the umbilical cord at placental insertion. Tissue bath experiment was performed on umbilical vessels and pathomorphologic data were collected according to the Royal College of Pathologists' protocol. After the development of basal tone, oxytocin and desmopressin did not enhance the vascular contraction, but the pathomorphological and ultrasonographic data were significantly different in the two groups. The results indicate that umbilical vessels might not have oxytocin or vasopressin receptors. The pathomorphologic and flowmetric differences could be the causes of small birth weight.

  16. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  17. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  18. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  19. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    Science.gov (United States)

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  20. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  1. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  2. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  3. Predicting intrapartum fetal compromise using the fetal cerebro-umbilical ratio.

    Science.gov (United States)

    Sabdia, S; Greer, R M; Prior, T; Kumar, S

    2015-05-01

    The aim of this study was to explore the association between the cerebro-umbilical ratio measured at 35-37 weeks and intrapartum fetal compromise. This retrospective cross sectional study was conducted at the Mater Mothers' Hospital in Brisbane, Australia. Maternal demographics and fetal Doppler indices at 35-37 weeks gestation for 1381 women were correlated with intrapartum and neonatal outcomes. Babies born by caesarean section or instrumental delivery for fetal compromise had the lowest median cerebro-umbilical ratio 1.60 (IQR 1.22-2.08) compared to all other delivery groups (vaginal delivery, emergency delivery for failure to progress, emergency caesarean section for other reasons or elective caesarean section). The percentage of infants with a cerebro-umbilical ratio cerebro-umbilical ratio between the 10th-90th centile and 9.6% of infants with a cerebro-umbilical ratio > 90th centile required delivery for the same indication (p cerebro-umbilical ratio was associated with an increased risk of emergency delivery for fetal compromise, OR 2.03 (95% CI 1.41-2.92), p cerebro-umbilical ratio measured at 35-37 weeks is associated with a greater risk of intrapartum compromise. This is a relatively simple technique which could be used to risk stratify women in diverse healthcare settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  5. Association of maternal and umbilical cord blood leptin concentrations and abnormal color Doppler indices of umbilical artery with fetal growth restriction

    Directory of Open Access Journals (Sweden)

    Elahe Zareaan

    2017-08-01

    Full Text Available Background: Fetal growth restriction (FGR is a condition with heterogeneous pathophysiology which characterized by fetal weight less than the tenth percentile for gestational age. Several factors have impact on maternal, placental and fetal due to growth restriction. Objective: The aim of this study was to investigate the relationship between levels of leptin in the cord, and serum leptin of mothers also abnormal color Doppler indices of umbilical artery with fetal growth restriction. Materials and Methods: This is a cross sectional study conducted in Isfahan, Iran, 2015-2016. We recruited 40 women with singleton pregnancies complicated by fetal growth restriction (Group I and 40 pregnant women with normal fetal growth (Group II with matched age. Maternal serum and umbilical artery leptin levels were determined with Enzyme-Linked immunosorben method. Also, color Doppler ultrasound of umbilical artery was performed. Results: Mean maternal and fetal leptin levels were lower in the FGR group compared to the normal group (36.58±(20.99 and 7.42 ±(4.08vs. 47.32±(22.50 and 30.49±(14.50 respectively. Also, mean fetal leptin level was lower in the group with abnormal color Doppler sonographic indices compared to the normal group (7. 40 ±(4.10vs 27.06±(15.80, respectively. Conclusion: This study indicated that maternal and fetal leptin levels are correlated with FGR originating from damaged placental function; also fetal leptin level can indicate changes in color Doppler sonographic indices.

  6. An umbilical polyp in an infant.

    Science.gov (United States)

    Swanson, David L; Pakzad, Betty

    2005-10-01

    The persistence at birth of the omphalomesenteric (vitelline) duct may result in life-threatening consequences. Early identification of this congenital anomaly is essential for prompt surgical treatment to eliminate the risk of prolapse and herniation. A neonatal umbilical polyp may indicate the presence of an omphalomesenteric duct remnant. We describe the diagnosis and surgical treatment of an infant with an umbilical polyp. We also present an overview of the diagnosis and treatment of vitelline duct remnants and their associated anomalies.

  7. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  8. Postprocedural Aspiration Test to Predict Adequacy of Dialysis Following Tunneled Catheter Placement

    International Nuclear Information System (INIS)

    Smith, Jason C.; Sullivan, Kevin L.; Michael, Beckie

    2006-01-01

    The objective of the study was to determine if a timed aspiration technique with a 20-ml syringe can be used to predict adequacy of blood flow in tunneled dialysis catheters. Sixteen patients referred for de novo placement or manipulation of failing tunneled hemodialysis catheters had the time it takes to fill a 20-ml syringe with the plunger fully withdrawn measured to the nearest tenth of a second. These measurements were correlated with flow rates recorded in dialysis just prior to (if failed catheter) and in the following dialysis session with adequacy determined as at least 300 ml/min. Syringe-filling time (22 catheters in 16 patients) was plotted against adequacy of dialysis. The mean time to fill a 20-ml syringe was 2.2 sec, with a range of 1.0-4.7 sec. The mean time to fill syringes for catheters with adequate dialysis was 1.7 ± 0.5 sec, and for inadequate catheters, it was 2.8 ± 0.8 sec. These differences are statistically significant (p < 0.001). Using a filling time of greater than or equal to 2 sec as a threshold gives the highest sensitivity (100%) for predicting inadequate dialysis while maintaining high specificity (75%). To achieve a specificity of 100%, a 3-sec cutoff would be necessary, but would lead to a sensitivity of only 20%. A simple and objective aspiration technique can be performed at the time of tunneled dialysis catheter placement/manipulation to reasonably predict adequacy of subsequent dialysis

  9. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. A comparative study on the uniaxial mechanical properties of the umbilical vein and umbilical artery using different stress-strain definitions.

    Science.gov (United States)

    Karimi, Alireza; Navidbakhsh, Mahdi

    2014-12-01

    The umbilical cord is part of the fetus and generally includes one umbilical vein (UV) and two umbilical arteries (UAs). As the saphenous vein and UV are the most commonly used veins for the coronary artery disease treatment as a coronary artery bypass graft (CABG), understating the mechanical properties of UV has a key asset in its performance for CABG. However, there is not only a lack of knowledge on the mechanical properties of UV and UA but there is no agreement as to which stress-strain definition should be implemented to measure their mechanical properties. In this study, the UV and UA samples were removed after caesarean from eight individuals and subjected to a series of tensile testing. Three stress definitions (second Piola-Kichhoff stress, engineering stress, and true stress) and four strain definitions (Almansi-Hamel strain, Green-St. Venant strain, engineering strain, and true strain) were employed to determine the linear mechanical properties of UVs and UAs. The nonlinear mechanical behavior of UV/UA was computationally investigated using hyperelastic material models, such as Ogden and Mooney-Rivlin. The results showed that the effect of varying the stress definition on the maximum stress measurements of the UV/UA is significant but not when calculating the elastic modulus. In the true stress-strain diagram, the maximum strain of UV was 92 % higher, while the elastic modulus and maximum stress were 162 and 42 % lower than that of UA. The Mooney-Rivlin material model was designated to represent the nonlinear mechanical behavior of the UV and UA under uniaxial loading.

  11. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    Science.gov (United States)

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  12. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  13. Intrauterine growth restriction is associated with structural alterations in human umbilical cord and decreased nitric oxide-induced relaxation of umbilical vein.

    Science.gov (United States)

    Peyter, A-C; Delhaes, F; Baud, D; Vial, Y; Diaceri, G; Menétrey, S; Hohlfeld, P; Tolsa, J-F

    2014-11-01

    Intrauterine growth restriction (IUGR) affects ∼8% of all pregnancies and is associated with major perinatal mortality and morbidity, and with an increased risk to develop cardiovascular diseases in adulthood. Despite identification of several risk factors, the mechanisms implicated in the development of IUGR remain poorly understood. In case of placental insufficiency, reduced delivery of oxygen and/or nutrients to the fetus could be associated with alterations in the umbilical circulation, contributing further to the impairment of maternal-fetal exchanges. We compared the structural and functional properties of umbilical cords from growth-restricted and appropriate for gestational age (AGA) term newborns, with particular attention to the umbilical vein (UV). Human umbilical cords were collected at delivery. Morphological changes were investigated by histomorphometry, and UV's reactivity by pharmacological studies. Growth-restricted newborns displayed significantly lower growth parameters, placental weight and umbilical cord diameter than AGA controls. Total cross-section and smooth muscle areas were significantly smaller in UV of growth-restricted neonates than in controls. Maximal vasoconstriction achieved in isolated UV was lower in growth-restricted boys than in controls, whereas nitric oxide-induced relaxation was significantly reduced in UV of growth-restricted girls compared to controls. IUGR is associated with structural alterations of the UV in both genders, and with a decreased nitric oxide-induced relaxation in UV of newborn girls, whereas boys display impaired vasoconstriction. Further investigations will allow to better understand the regulation of umbilical circulation in growth-restricted neonates, which could contribute to devise potential novel therapeutic strategies to prevent or limit the development of IUGR. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  15. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  16. Umbilical endometriosis mimicking as papilloma to general surgeons: A case report

    Directory of Open Access Journals (Sweden)

    A Singh

    2012-05-01

    Full Text Available IntroductionCutaneous or umbilical endometriosis is a rare entity that isoften overlooked because of chronic abdominal pain. Wepresent a case of umbilical hernia that presented to thegeneral surgeons due to chronic abdominal pain and nodulein the umbilicus, which was clinically diagnosed as umbilicalpapilloma.Case presentationA 48-year old multiparous Caucasian woman presented withpainful nodule in the umbilicus for two and half years. Thenodule was excised and the histopathological diagnosis wasumbilicus endometriosis.ConclusionUmbilical endometriosis is a very rare disease but should beconsidered as a differential diagnosis in women presentingwith umbilical swelling.

  17. Umbilical blood flow ultrasound characteristics of perioperative fetal intrauterine hypoxia and their relationship with maternal and fetal oxidative stress injury

    Directory of Open Access Journals (Sweden)

    Yu-Mei He

    2017-05-01

    Full Text Available Objective: To study the relationship between umbilical blood flow ultrasound characteristics of perioperative fetal intrauterine hypoxia and maternal as well as fetal oxidative stress injury. Methods: 108 puerperae giving birth in our hospital between May 2014 and October 2016 were selected and divided into normal pregnancy group with neonatal Apgar score >7 points and intrauterine hypoxia group with neonatal Apgar score ≤7 points, color Doppler diasonograph was used to determine umbilical blood flow ultrasound parameters, umbilical cord blood was collected to determine the levels of oxidative stress products, and the placenta was collected to determine the levels of oxidative stress products and related apoptosis molecules. Results: During 24–30 weeks, 31–36 weeks and 37–41 weeks of pregnancy, umbilical blood flow resistance index (RI, pulsatility index (PI and diastolic velocity/systolic velocity (S/D of intrauterine hypoxia group were significantly higher than those of normal pregnancy group (P<0.05; malondialdehyde (MDA, oxidized low-density lipoprotein (ox- LDL, 8-isoprostanes (8-iso, and heat shock protein 70 (HSP-70 levels in umbilical cord blood of intrauterine hypoxia group were significantly higher than those of normal pregnancy group (P<0.05, MDA, oxLDL, 8-ios, HSP-70, Fas, FasL and Bax levels in placenta tissue were significantly higher than those of normal pregnancy group (P<0.05, and Bcl-2 and XIAP levels were significantly lower than those of normal pregnancy group (P<0.05; RI, PI and S/ D were positively correlated with MDA, oxLDL, 8-ios and HSP-70 levels in umbilical cord blood and placenta tissue, positively correlated with Fas, FasL and Bax levels in placenta tissue, and negatively correlated with Bcl-2 and XIAP levels in placental tissue. Conclusions: The increased umbilical blood flow resistance and decreased flow volume of fetal intrauterine hypoxia are closely related to maternal, fetal and placental oxidative

  18. The umbilical and paraumbilical veins of man.

    Science.gov (United States)

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  19. ACOG committee opinion number 399, February 2008: umbilical cord blood banking.

    Science.gov (United States)

    2008-02-01

    Two types of banks have emerged for the collection and storage of umbilical cord blood--public banks and private banks. Public banks promote allogenic (related or unrelated) donation, analogous to the current collection of whole blood units in the United States. Private banks were initially developed to store stem cells from umbilical cord blood for autologous use (taken from an individual for subsequent use by the same individual) by a child if the child develops disease later in life. If a patient requests information on umbilical cord blood banking, balanced and accurate information regarding the advantages and disadvantages of public versus private banking should be provided. The remote chance of an autologous unit of umbilical cord blood being used for a child or a family member (approximately 1 in 2,700 individuals) should be disclosed. The collection should not alter routine practice for the timing of umbilical cord clamping. Physicians or other professionals who recruit pregnant women and their families for for-profit umbilical cord blood banking should disclose any financial interests or other potential conflicts of interest.

  20. Alcohol application natural drying of umbilical cord

    International Nuclear Information System (INIS)

    Shafique, M.F.; Ali, S.; Roshan, E.; Jamal, S.

    2006-01-01

    To compare the outcome, between the application of Alcohol and natural drying to umbilical stump in low risk newborns. Newborns delivered in Military Hospital and Combined Military Hospital Rawalpindi were randomized into group A (70% Alcohol) and group B (No antiseptic). In group A, 70% Alcohol was applied once daily to the umbilical stump, whereas no antiseptic was applied in group B. These newborns were followed till four weeks of life. Age at separation of umbilical cord was noted. Cases showing signs of neonatal sepsis and omphalitis were documented. Of 100 singleton full-term newborns enrolled, 90 completed the study. No newborn in either group developed a cord infection or neonatal sepsis. The difference of cord separation time between the two groups was statistically significant. Evidence does not support continued use of alcohol for low risk newborn cord care. (author)

  1. Birth weight and characteristics of endothelial and smooth muscle cell cultures from human umbilical cord vessels

    Directory of Open Access Journals (Sweden)

    Lurbe Empar

    2009-04-01

    Full Text Available Abstract Background Low birth weight has been related to an increased risk for developing high blood pressure in adult life. The molecular and cellular analysis of umbilical cord artery and vein may provide information about the early vascular characteristics of an individual. We have assessed several phenotype characteristics of the four vascular cell types derived from human umbilical cords of newborns with different birth weight. Further follow-up studies could show the association of those vascular properties with infancy and adulthood blood pressure. Methods Endothelial and smooth muscle cell cultures were obtained from umbilical cords from two groups of newborns of birth weight less than 2.8 kg or higher than 3.5 kg. The expression of specific endothelial cell markers (von Willebrand factor, CD31, and the binding and internalization of acetylated low-density lipoprotein and the smooth muscle cell specific α-actin have been evaluated. Cell culture viability, proliferation kinetic, growth fraction (expression of Ki67 and percentage of senescent cells (detection of β-galactosidase activity at pH 6.0 have been determined. Endothelial cell projection area was determined by morphometric analysis of cell cultures after CD31 immunodetection. Results The highest variation was found in cell density at the confluence of endothelial cell cultures derived from umbilical cord arteries (66,789 ± 5,093 cells/cm2 vs. 45,630 ± 11,927 cells/cm2, p 2, p Conclusion The analysis of umbilical cord artery endothelial cells, which demonstrated differences in cell size related to birth weight, can provide hints about the cellular and molecular links between lower birth weight and increased adult high blood pressure risk.

  2. Umbilical Cord Blood: Counselling, Collection, and Banking.

    Science.gov (United States)

    Armson, B Anthony; Allan, David S; Casper, Robert F

    2015-09-01

    To review current evidence regarding umbilical cord blood counselling, collection, and banking and to provide guidelines for Canadian health care professionals regarding patient education, informed consent, procedural aspects, and options for cord blood banking in Canada. Selective or routine collection and banking of umbilical cord blood for future stem cell transplantation for autologous (self) or allogeneic (related or unrelated) treatment of malignant and non-malignant disorders in children and adults. Cord blood can be collected using in utero or ex utero techniques. Umbilical cord blood counselling, collection, and banking, education of health care professionals, indications for cord blood collection, short- and long-term risk and benefits, maternal and perinatal morbidity, parental satisfaction, and health care costs. Published literature was retrieved through searches of Medline and PubMed beginning in September 2013 using appropriate controlled MeSH vocabulary (fetal blood, pregnancy, transplantation, ethics) and key words (umbilical cord blood, banking, collection, pregnancy, transplantation, ethics, public, private). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. There were no date limits, but results were limited to English or French language materials. Searches were updated on a regular basis and incorporated in the guideline to September 2014. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, and national and international medical specialty societies. The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). Umbilical cord blood is a readily available source of hematopoetic stem cells used with increasing frequency as an alternative to

  3. HDR monotherapy for prostate cancer: A simulation study to determine the effect of catheter displacement on target coverage and normal tissue irradiation

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Roos, Martin A.; Aluwini, Shafak

    2011-01-01

    Purpose: The aim of this study was to systematically analyse the effect of catheter displacements both on target coverage and normal tissue irradiation in fractionated high dose rate (HDR) prostate brachytherapy, using a simulation study, and to define tolerances for catheter displacement ensuring that both target coverage and normal tissue doses remain clinically acceptable. Besides the effect of total implant displacement, also displacements of catheters belonging to selected template rows only were evaluated in terms of target coverage and normal tissue dose, in order to analyse the change in dose distribution as a function of catheter dwell weight and catheter location. Material and methods: Five representative implant geometries, with 17 catheters each, were selected. The clinical treatment plan was compared to treatment plans in which an entire implant displacement in caudal direction over 3, 5, 7 and 10 mm was simulated. Besides, treatment plans were simulated considering a displacement of either the central, most ventral or most dorsal catheter rows only, over 5 mm caudally. Results: Due to displacement of the entire implant the target coverage drops below the tolerance of 93% for all displacements studied. The effect of displacement of the entire implant on organs at risk strongly depended on the patient anatomy; e.g., for 80% of the implant geometries the V 80 of the rectum exceeded its tolerance for all displacements. The effect of displacement of catheters belonging to selected template rows depended strongly on the relative weight of each catheter row when considering the target coverage and on its location when considering the dose in the organs at risk. Conclusion: This study supports the need for a check of the catheter locations before each fraction and correction of deviations of the catheter position exceeding 3 mm.

  4. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    Science.gov (United States)

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  5. Bacterial contamination in a special care baby unit of a tertiary ...

    African Journals Online (AJOL)

    Background: Nosocomial infections pose a great challenge on healthcare systems. Although surfaces in neonatal wards, umbilical stump wounds and catheter are responsible for a high number of nosocomial infections due to bacteria. The aim of this study was to determine the bacterial profile of air and surface ...

  6. Urinary incontinence and indwelling urinary catheters in acutely admitted elderly patients: relationship with mortality, institutionalization, and functional decline

    NARCIS (Netherlands)

    Bootsma, A. M. Jikke; Buurman, Bianca M.; Geerlings, Suzanne E.; de Rooij, Sophia E.

    2013-01-01

    To study differences in functional status at admission in acutely hospitalized elderly patients with urinary incontinence, a catheter, or without a catheter or incontinence (controls) and to determine whether incontinence or a catheter are independent risk factors for death, institutionalization, or

  7. Induction of labour by balloon catheter with extra-amniotic saline infusion (BCEAS): a randomised comparison with PGE2 vaginal pessaries

    DEFF Research Database (Denmark)

    Lyndrup, J; Nickelsen, Carsten Nahne Amtoft; Weber, Tom

    1994-01-01

    section followed BCEAS than PGE2 (29% and 10%, respectively; P infectious complications were not recorded following BCEAS. No difference was apparent in the status of the neonates (judging from Apgar scores and umbilical artery pH and SBE). The women, delivering vaginally, commented......OBJECTIVE: A new method for induction of labour--balloon catheter with extra-amniotic saline infusion (BCEAS)--is evaluated in randomised comparison with prostaglandin E2 (PGE2) in vaginal pessaries. STUDY GROUP: One-hundred and nine pregnant women with unfavourable cervices. MAJOR OUTCOME MEASURES......: The efficiency of inducing vaginal delivery and the level of 'disadvantages following induction of labour' (DisFIL scorings). RESULTS: Overall, BCEAS was less efficient inducing vaginal delivery than vaginal PGE2 (P

  8. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  9. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  10. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  11. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

    Science.gov (United States)

    Anter, Elad; Tschabrunn, Cory M; Contreras-Valdes, Fernando M; Li, Jianqing; Josephson, Mark E

    2015-09-01

    During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Umbilical site for temporary colostomy in anorectal malformations: is ...

    African Journals Online (AJOL)

    Umbilical site for temporary colostomy in anorectal malformations: is it cosmetically preferable? Taha Alkhatrawi, Radi Elsherbini and Djamal Ouslimane. Purpose In an attempt to minimize the scars and improve the cosmetic outcome in children, the umbilical site has been chosen for colostomy formation in patients with.

  13. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416±45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency

  14. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo [Kyunghee University Hospital, seoul (Korea, Republic of)

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416{+-}45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency.

  15. Prospect for application of umbilical cord blood to clinical treatment of radiation sickness

    International Nuclear Information System (INIS)

    Jia Tingzhen; Ke Xiaoyan

    1998-01-01

    Objective: To look forward to the prospect for application of umbilical cord blood to clinical treatment of radiation sickness by analyzing the results using umbilical cord blood in laboratory experiments and clinical research. Method: The data on umbilical cord blood published in literature are reviewed. Results: The umbilical blood is rich in hematopoietic stem/progenitor cells, low in immunological activity of lymphocytes, expanded significantly ex vivo under selected culture condition readily available and collected easily. Conclusion: With the above advantages, the prospect for application of umbilical cord blood is encouraging, particularly in the clinical treatment of radiation sickness

  16. Upcycling umbilical cords: bridging regenerative medicine with neonatology.

    Science.gov (United States)

    Moreira, Alvaro; Alayli, Yasmeen; Balgi, Saloni; Winter, Caitlyn; Kahlenberg, Samuel; Mustafa, Shamimunisa; Hornsby, Peter

    2017-11-27

    Preterm birth is a major health concern that affects 10% of all worldwide deliveries. Many preterm infants are discharged from the hospital with morbidities that lead to an increased risk for neurodevelopmental impairment, recurrent hospitalizations, and life-long conditions. Unfortunately, the treatment of these conditions is palliative rather than curative, which calls for novel and innovative strategies. Progress in regenerative medicine has offered therapeutic options for many of these conditions. Specifically, human umbilical cord mesenchymal stem cells (MSCs) and cord blood (UCB) cells have shown promise in treating adult-onset diseases. Unlike bone-marrow and embryonic derived stem cells, umbilical cord-derived cells are easily and humanely obtained, have low immunogenicity, and offer the potential of autologous therapy. While there are several studies to uphold the efficacy of umbilical cord MSCs in adult therapies, there remains an unmet need for the investigation of its use in treating neonates. The purpose of this review is to provide a summary of current information on the potential therapeutic benefits and clinical applicability of umbilical cord MSCs and UCB cells. Promising preclinical studies have now led to a research movement that is focusing on cell-based therapies for preterm infants.

  17. umbilical cord parameters in ilorin: correlates and foetal outcome

    African Journals Online (AJOL)

    2014-08-08

    Aug 8, 2014 ... The foetal outcomes were assessed by APGAR scores, birth weight, admission to neonatal intensive ... between the umbilical cord parameters and perinatal events such as Apgar scores and birth weight. .... Suzuki S, Fuse Y. Length of the Umbilical Cord and. Perinatal Outcomes in Japanese Singleton ...

  18. Y-to-V umbilicoplasty for proboscoid umbilical hernia | Almetaher ...

    African Journals Online (AJOL)

    Background/purpose Several techniques are proposed for reconstruction of proboscoid umbilical hernia in the pediatric patients. In this work, we reported our experience with Y-to-V umbilicoplasty in the surgical repair of proboscoid umbilical hernia in infants and children. Patients and methods A 3-year prospective study ...

  19. Adherence of staphylococcus aureus to catheter tubing inhibition by quaternary ammonium compounds.

    Science.gov (United States)

    Iyamba, Jean-Marie Liesse; Okombe, Daniel Tassa; Zakanda, Francis Nsimba; Malongo, Trésor Kimbeni; Unya, Joseph Welo; Lukukula, Cyprien Mbundu; Kikuni, Ntondo Za Balega Takaisi

    2016-01-01

    S. aureus is a Gram positive bacterium which is responsible for a wide range of infections. This pathogen has also the ability to adhere to biotic or abiotic surface such as central venous catheter (CVC) and to produce a biofilm. The aim of this study was to evaluate the effect of hexadecyltrimethyl ammonium bromide (HTAB) and Hexadecylbetainate chloride (HBC) on Staphylococcus aureus adherence to the catheter tubing and on bacteria growth. Broth microdilution method was used to determine the Minimal Inhibitory Concentration (MIC). The detection of slime production was done by Congo Red Agar method, and the adherence of bacteria to the catheter tubing was evaluated by the enumeration of bacteria on plate counts. The results of this study showed that the MICs of HTAB were ranged from 0.125 to 0.5 µg/mL, and those of HBC fluctuated between 2 to 8 µg/mL. HTAB and HBC inhibited bacteria adhesion on the surface of the catheter tubing. This study showed that HTAB and HBC can prevent the adherence of S. aureus strains to the surface of catheter tubing, suggesting that they could be used to prevent the risk of catheter related bloodstream infections.

  20. Relationship between the tensile strengths and diameters of human umbilical cords.

    Science.gov (United States)

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-05-01

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. A newborn liver mass that never existed: a somber reminder of embryonic ties between umbilical vein and portal venous system

    Directory of Open Access Journals (Sweden)

    Haafiz A

    2011-12-01

    Full Text Available Allah Haafiz1, Jonathan L Williams2, Joel M Andres1, Don A Novak11Pediatric Gastroenterology, Hepatology; 2Department of Pediatric Radiology, University of Florida College of Medicine, Gainesville, FL, USAAbstract: A 6-day-old, known to have transposition of the great vessels, received care in the neonatal intensive care unit at a tertiary care center. A computed tomography scan was performed for abdominal distention and upper gastrointestinal bleeding, which revealed a “mass lesion” in the left liver lobe. Analysis of antecedent events and the clinical and laboratory course uncovered an iatrogenic etiology and pathogenesis of the lesion. As the nature of the lesion was clarified, no specific therapy was required. This case is presented to show a serious yet preventable complication of a commonly performed procedure.Keywords: portal vein thrombosis, liver mass, umbilical venous catheter

  2. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  3. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  4. Mercury in the Umbilical Cord: Implications for Risk Assessment for Minamata Disease

    DEFF Research Database (Denmark)

    Dalgård, Christine; Grandjean, Philippe; Jørgensen, Poul Jørgen

    1994-01-01

    Umbilical cord tissue was obtained from 50 births in the Faroe Islands, where high mercury intake is due to ingestion of pilot whale meat. The mercury concentration correlated significantly with the frequency of maternal whale meat dinners during pregnancy and with mercury concentrations in umbil...... mercury concentration of 4.95 nmol/g dry weight in Minamata would correspond to 668 nmol/l cord blood and 114 nmol/g maternal hair. These levels agree well with other evidence of susceptibility of the fetus to increased exposure to methylmercury....... in umbilical cord blood and in maternal hair. The results were compared with published values for mercury in umbilical cord tissue from 12 infants diagnosed with congenital methylmercury poisoning in Minamata, Japan. From the regression coefficients obtained in the Faroese samples, the median umbilical cord...

  5. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  6. Study of mesanchymal stem cells derived from human umbilical cord vein wall and determining the Process of differentiation to cartilage and bone

    Directory of Open Access Journals (Sweden)

    MohammadAli Zare

    2015-01-01

    Full Text Available Background: Mesenchymal stem cells (MSCs comprise a rare population of multipotent progenitors capable of supporting hematopoiesis and differentiating into three (osteogenic, adipogenic, and chondrogenic or more (myogenic, cardiomyogenic, etc. lineages. Due to this ability, MSCs appear to be an attractive tool in the context of tissue engineering and cell-based therapy. Currently, bone marrow represents the main source of MSCs for both experimental and clinical studies. The purpose of this study was isolation and quantitative comparison of mesenchymal stem cells derived from umbilical vein. Materials and Methods: In this study, 35 samples of umbilical cord of healthy full- term newborn were studied. Results: The cells had fibroblastoid like appearance and had revealed the potential to differentiate into three linage of bone, Adipose and cartilage. Surface markers for mesenchymal nature were their demonstratives. Conclusion: Based on our findings the mesenchymal stem cells, from umbilical vein wall can be isolated, cultured and differentiated into three categories of bone, cartilage and adipose.

  7. Umbilical melanoma: case report and review of anatomical and therapeutic aspects

    International Nuclear Information System (INIS)

    Brandao, Eduardo Miranda; Gomes, Alexandre Santos de Almeida; Ribeiro, Edilana Sa; Vilaca, Thiago Guimaraes; Macedo, Francisco Igor Bulcao de; Santos, Rogerio Luiz dos; Pernambuco Univ., Recife, PE

    2005-01-01

    , skin, subcutaneous cellular tissue and peritoneum. Continuity with the round ligament and the urachus allows dissemination through those structures. Such facts justify the difficulty faced while establishing vertical or horizontal growth of Melanomas, as well as using Breslow measurements in that area. In addition to that, the lymphatic drainage, as a function of the classical definition of the Sappey Line, can be directed towards the axillary or inguinal areas, thus making it essential to carry out lymphoscintillography and lymphatic mapping. Conclusion: Umbilical melanoma is a rare occurrence. Due to its embryological and anatomical peculiarities, its clinical histopathological evaluation entails difficulties and demands knowledge of local lymphatic drainage aspects in order to determine its pattern of dissemination. Lymphoscintillography and lymphatic mapping are imposed with sentinel lymph node research as exclusive means for identifying the routes of lymphatic drainage. In this case, we were able to define the drainage for the left axilla and to recover the corresponding lymph nodes, so that histopathological and immunohistochemical exams could be carried out. (author)

  8. A comparative study on trans-umbilical single-port laparoscopic approach versus conventional repair for incarcerated inguinal hernia in children

    OpenAIRE

    Jun, Zhang; Juntao, Ge; Shuli, Liu; Li, Long

    2016-01-01

    Purpose: The purpose of this study is to determine whether singleport laparoscopic repair (SLR) for incarcerated inguinal hernia in children is superior toconventional repair (CR) approaches. Method: Between March 2013 and September 2013, 126 infants and children treatedwere retrospectively reviewed. All the patients were divided into three groups. Group A (48 patients) underwent trans-umbilical SLR, group B (36 patients) was subjected to trans-umbilical conventional two-port laparoscopic rep...

  9. CMS ECAL Endcap (EE) - Preparatory work for umbilical noise studies

    CERN Multimedia

    Lodge, T

    2007-01-01

    Possible mapping solution, done inside connector, top and bottom sides of MB MB with umbilical + free pins, all identical until position on Dee known Then pins to connector in specific order for that position. All SC umbilicals to mating connector identical.

  10. Umbilicoplasty in children with huge umbilical hernia | Komlatsè ...

    African Journals Online (AJOL)

    With a mean follow-up of 10 months, we had 10 excellent results and two fair results according to our criteria. Conclusion: Our two lateral fl aps umbilicoplasty is well-adapted to HUH in children. Itis simple and assures a satisfactory anatomical and cosmetic result. Key words: Children, huge umbilical hernia, Togo, umbilical ...

  11. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  12. Optimization of informed consent for umbilical cord blood banking.

    Science.gov (United States)

    Sugarman, Jeremy; Kurtzberg, Joanne; Box, Tamara L; Horner, Ronnie D

    2002-12-01

    The purpose of this project was to evaluate the informed consent process for donation to a public umbilical cord blood bank. Telephone interviews were conducted with 170 women who had given consent to donate their newborn infants' umbilical cord blood. Of the 170 women who were contacted, 96.8% of the women reported that all their questions had been answered. Nevertheless, approximately one third of the respondents did not consider themselves to be in research, and almost one quarter of the respondents did not know how to contact the umbilical cord blood bank if they or their infant became seriously ill. Further, a substantial proportion of the respondents did not understand the full range of alternatives to donation and incorrectly endorsed potential benefits. Informed consent could be optimized by (1) having those personnel who obtain consent emphasize that banking involves research and to explain the true benefits of donation, (2) ensuring that parents know how and when to contact the umbilical cord blood bank after donation, and (3) using phone surveys to continue assessments and to monitor changes in the process.

  13. Resuscitation of Newborn Babies

    African Journals Online (AJOL)

    Ann Burgess

    in which neonatal resuscitation was a central component1. ... together with an umbilical catheter through which they are given, but if ... drugs: Insert an umbilical venous cannula, and ... Case history from Berega Hospital, Tanzania. Following a ...

  14. Hernia of the umbilical cord associated with a patent omphalomesenteric duct

    Directory of Open Access Journals (Sweden)

    M Raicevic

    2017-01-01

    Full Text Available Congenital hernia of the cord is a different type of ventral abdominal wall defect in which the bowel usually herniates into the base of normally inserted umbilical cord through a patent umbilical ring. It is rare congenital anomaly with incidence of 1 in 5000. Although it was described as a distinct entity since 1920s it is often misdiagnosed as a small omphalocele. We present an unusal case of term male newborn with umbilical cord hernia associated with patent omphalomesenteric duct. The diagnose was made after birth despite antenatal ultrasound scans and it is managed successfully with uneventful recovery. If this is missdiagnosed, it could cause iatrogenic atresia of the ileum by clamping the umbilical cord after birth.

  15. Ultrasonic character istics and clinical significance of umbilical cord blood flow in acute fetal distress

    Directory of Open Access Journals (Sweden)

    Wei Dai, Yin Xu

    2016-11-01

    Full Text Available Objective: To study ultrasonic characteristics of umbilical cord blood flow in acute fetal distress and its correlation with umbilical artery blood gas parameters, oxidative stress parameters, neonatal brain injury and myocardial injury. Methods: The pregnant women delivered in Department of Obstetrics of our hospital were chosen during the period from May 2012 to August 2015. The pregnant women with acute fetal distress were included in the distress group, and the healthy pregnant women with no acute fetal distress were included in the control group. The resistance index (RI, pulsatility index (PI and systolic/diastolic (S/D ratio of umbilical artery were measured at 24–30 weeks, 31–36 weeks and 37–41 weeks of pregnancy. After delivery, umbilical artery blood was taken for analysis of blood gas and determination of oxidative stress parameters. The venous blood of newborns was taken to measure the myocardial injury and brain injury parameters. Results: At 24–30 weeks, 31–36 weeks and 37–41 weeks of pregnancy, RI, S/D and PI in pregnant women of distress group were significantly higher than those in control group. The pH, contents of arterial partial pressure of oxygen, vitamin C, vitamin E, superoxide dismutase and glutathione peroxidase in umbilical artery blood in pregnant women of distress group was significantly lower than those in control group and negatively correlated with the umbilical artery RI, PI and S/D. The contents of partial pressure of carbon dioxide in artery, lactic acid and malondialdehyde in pregnant women of distress group were significantly higher than those in control group and positively correlated with the umbilical artery RI, PI and S/D. The contents of lactate dehydrogenase, hydroxybutyrate dehydrogenase, creatine kinase, creatine kinase-MB, S100B, neuron-specific enolase, creatine kinase-BB and Tau in newborns' venous blood in distress group were significantly higher than those in control group and

  16. [Catheter-associated bloodstream infections: implementation of a new consensus protocol].

    Science.gov (United States)

    Urrea Ayala, M; Rozas Quesada, L

    2009-07-01

    Catheter-associated bloodstream infection is highly prevalent and often associated with fatal complications. Some studies have shown that applying preventive interventions could help to reduce and control this type of infection. To determine whether a new consensus protocol for the manipulation and maintenance of central venous catheters would decrease catheter-associated bloodstream infections (CA-BSIs) in paediatric patients. To evaluate its compliance in intensive care units. Prospective study in the paediatric (PICU) and neonatal (NICU) intensive cares units, haematology, oncology and hospital wards in a Maternal and Paediatric reference Hospital in Barcelona. The study period is divided into two periods: before (first semester) and after the start of the new protocol (second semester) in 2007. The most important changes have been the insertion of the hermetic connection in the proximal and distal site (between the line and the syringe) of the central venous catheter (CVC), the labelling of the medication line and the CVC with the date of placement. A check-list to evaluate compliance was introduced in both intensive care units (paediatrics and neonatal) during the second study period. The rates of bloodstream infection per 1000 catheter-days were assessed. The rate of bloodstream infections per 1000 catheter-days before and after the start of the new protocol was 5.7 and 4.9 in PICU; 24.6 and 18.0 in NICU; 7.6 and 4.6 in haematology-oncology, and 11.9 and 10.3 in hospital wards. As regards compliance to the protocol, we found that proximal sealed connectors were used in more than 95% of the cases and up to 85% of the central venous catheter were labelled with the insertion date in both intensive care units. A consensus protocol for the use and maintenance of central venous catheters and healthcare worker training helped to control the rate of CA-BSIs. We reaffirm the importance of epidemiological surveillance as a measure for controlling nosocomial infections.

  17. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  18. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  19. Reducing catheter-associated urinary tract infections: a quality-improvement initiative.

    Science.gov (United States)

    Davis, Katherine Finn; Colebaugh, Ann M; Eithun, Benjamin L; Klieger, Sarah B; Meredith, Dennis J; Plachter, Natalie; Sammons, Julia Shaklee; Thompson, Allison; Coffin, Susan E

    2014-09-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common health care-associated infections in the United States, yet little is known about the prevention and epidemiology of pediatric CAUTIs. An observational study was conducted to assess the impact of a CAUTI quality improvement prevention bundle that included institution-wide standardization of and training on urinary catheter insertion and maintenance practices, daily review of catheter necessity, and rapid review of all CAUTIs. Poisson regression was used to determine the impact of the bundle on CAUTI rates. A retrospective cohort study was performed to describe the epidemiology of incident pediatric CAUTIs at a tertiary care children's hospital over a 3-year period (June 2009 to June 2012). Implementation of the CAUTI prevention bundle was associated with a 50% reduction in the mean monthly CAUTI rate (95% confidence interval: -1.28 to -0.12; P = .02) from 5.41 to 2.49 per 1000 catheter-days. The median monthly catheter utilization ratio remained unchanged; ∼90% of patients had an indication for urinary catheterization. Forty-four patients experienced 57 CAUTIs over the study period. Most patients with CAUTIs were female (75%), received care in the pediatric or cardiac ICUs (70%), and had at least 1 complex chronic condition (98%). Nearly 90% of patients who developed a CAUTI had a recognized indication for initial catheter placement. CAUTI is a common pediatric health care-associated infection. Implementation of a prevention bundle can significantly reduce CAUTI rates in children. Copyright © 2014 by the American Academy of Pediatrics.

  20. Umbilical cord rupture: a case report and review of literature.

    Science.gov (United States)

    Naidu, Madhusudhan; Nama, Vivek; Karoshi, Mahantesh; Kakumani, Vijayasri; Worth, Richard

    2007-01-01

    The umbilical cord acts as a mechanical conduit between the fetus and placenta, allowing movement of water and nutrient substances between the fetal circulation and the amniotic fluid. Complications can occur antenatally or intranatally and are usually acute events that require immediate delivery to prevent intrauterine death. Even though the majority of the cord complications are unpreventable, significant improvement in perinatal mortality and morbidity can be achieved if such an event can be predicted. Umbilical cord rupture is not uncommon, but significantly underreported. We present an unusual cause of umbilical cord rupture and a review of literature.

  1. Efficacy of Minocycline and EDTA Lock Solution in Preventing Catheter-Related Bacteremia, Septic Phlebitis, and Endocarditis in Rabbits

    Science.gov (United States)

    Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert

    2002-01-01

    To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P phlebitis, and endocarditis in rabbits. PMID:11796338

  2. Considerations on umbilical cord resistance to traction

    Directory of Open Access Journals (Sweden)

    Bianca Hanganu

    2017-12-01

    Full Text Available Neonaticide represents a particular issue both to society and forensic field, being admitted nowadays as a crime all over the world. Apart from common gross and microscopic examination of the newborn cadaver, thorough examination of the umbilical cord during autopsy proved many times its major utility in solving neonaticide cases. Although by its constituents, the umbilical cord is a quite resistant structure to bending and compression, mechanical properties vary along its surface, with gestational age or various pregnancy disorders, as well as genetic anomalies of the fetus, so that a rupture may occur. The authors present the case of a newborn found dead in a sink – about whom mother states that he accidentally fell in the feces, the moment of the birth being a surprise – and discuss on the circumstances when the umbilical cord may rupture. This issue is most important when is a need to differentiate between a true accident and an intentional newborn homicide by the mother set forth as an accident.

  3. Certain Red Blood Cell Indices of Maternal and Umbilical Cord ...

    African Journals Online (AJOL)

    Uche

    Background: Umbilical cord blood analysis may give a clue to the state of health of both pregnant mothers and their neonates. However ... Keywords: Umbilical cord blood; maternal blood; haemoglobin concentration; packed cell volume; red cell indices. Received on .... The packed cell volume was measured using the.

  4. Survey of Umbilical Cord care and Separation time in Healthy ...

    African Journals Online (AJOL)

    Background: The interval between delivery and umbilical cord separation varies worldwide. Some maternal, foetal and perinatal factors including cord care practices are known to affect this interval. Objectives: To establish the mean umbilical cord separation time and the effect of maternal and infant characteristics, perinatal ...

  5. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  6. Liver Hematoma Presented as Midgut Volvulus Due To Medical Error: A Case Report

    Directory of Open Access Journals (Sweden)

    Karimi

    2016-02-01

    Full Text Available Introduction The use of an umbilical catheterization is a usual practice in neonatal units. The insertion of the catheter has potential complications. Case Presentation Here, we report on our observation of a seven-day-old female newborn admitted for an abdominal distention and vomiting bile. Initially, diagnosis was midgut volvulus, for which an operation was performed. During the surgery, no intestinal malrotation, mesenteric defect or atresia was observed. Postoperative diagnosis was abdominal wall hematoma and rand ligament and ileus, as well as, sub-capsular liver hematoma. The patient had been hospitalized at birth at a neonatal intensive care unit (NICU. With the appearance of icterus on the first day of life, at the NICU tried to insert the umbilical catheter that had been filed. Conclusions The complication found in the patient was the result of an aggressive act (the umbilical catheter insertion. This intervention should not be carried out unless there are clear indications, and if so, it should be done with much care.

  7. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  8. Polybrominated diphenyl ethers in paired samples of maternal and umbilical cord blood plasma and associations with house dust in a Danish cohort

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Thomsen, Cathrine; Frøshaug, May

    2010-01-01

    determined in placental tissue from the same individuals, and the relationship with the external exposure from house dust from the participants' homes was explored. Samples of maternal and umbilical cord plasma from a cohort of 51 pregnant women from the Copenhagen area were collected. Paired maternal...... and umbilical cord plasma were analysed for BDE-28, 37, 47, 85, 99, 100, 119, 138, 153, 154, 183, 209 and the brominated biphenyl BB-153 using automated SPE extraction and GC-HRMS for the tri- to hepta-BDEs and GC-LRMS (ECNI) for BDE-209. PBDEs were detected in all maternal and umbilical cord plasma samples...

  9. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  10. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  11. A survey of the use of arterial catheters in anesthetized dogs and cats: 267 cases.

    Science.gov (United States)

    Trim, Cynthia M; Hofmeister, Erik H; Quandt, Jane E; Shepard, Molly K

    2017-01-01

    To describe the clinical practice of insertion of arterial catheters in anesthetized dogs and cats, to document complications of arterial catheterization, and to determine risk factors associated with the complications. Prospective clinical study and retrospective evaluation of medical records. University teaching hospital. Dogs (n = 251) and 13 cats anesthetized for clinical procedures with arterial catheters inserted for blood pressure monitoring. None. Details of the animal and catheter were collected at the time of anesthesia. On the following day, the catheter site was palpated and observed for abnormalities and the medical records of all animals were reviewed retrospectively for complications. Details of catheter placement were available for 216 catheters: 158 catheters in a dorsal pedal artery, 50 catheters in the median caudal (coccygeal) artery, 6 in the median artery, and 1 each in a cranial tibial and lingual artery. Blood pressure was obtained from 200 catheters, and 12 catheters failed before the end of anesthesia. Postoperative observational data obtained from 112 catheters described a palpable arterial pulse at 73 sites and no pulse at 21 sites. No risk factor for arterial occlusion was identified. No complications resulting from arterial catheterization were noted in the medical records. Arterial catheterization resulted in loss of a peripheral pulse postoperatively in 21/94 (22.3%) of animals examined, although no evidence of tissue ischemia was noted in the medical records of any of the patients in this study. These results suggest that insertion of a catheter in the dorsal pedal or coccygeal arteries was not associated with a high risk for complications. However, the course of arterial occlusion postoperatively warrants further investigation. © Veterinary Emergency and Critical Care Society 2016.

  12. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  13. Ultrastructural characterization of bovine umbilical cord blood cells Caracterização ultra-estrutural das células sanguíneas do cordão umbilical bovino

    Directory of Open Access Journals (Sweden)

    Gustavo C Rodrigues

    2010-10-01

    Full Text Available The umbilical cord blood (UCB is an important source of pluripotent stem cells, which motivated researches on ontogeny and transplantation. The morphological characterization of umbilical cord cells is the first step to establish subsequent experiments on these areas. Although some information on humans can be found, no data on UCB is available for bovines. Therefore, this work is the first attempt to conduct an ultrastructural characterization of bovine umbilical cord blood. Blood was collected from the umbilical cord of twenty fetuses by punction of the umbilical vein. Samples were processed for whole leucocytes observation by centrifugation and the buffy coat was collected. Cells were washed and pelleted and prepared according to the standard protocol of the transmission electron microscopy. The presence of cells with morphologic characteristics compatible with the precursors from the erythrocytic, neutrophilic, eosinophilic, basophilic, and lymphocytic lineages was observed. Atypical cells with peculiar morphological features, strongly similar to apoptotic cells, were seen. Bovine neutrophils with three types of cytoplasmic granules were also found in the blood. The ultrastructural characteristics of observed bovine UCB cells where similar to those found in other species, suggesting that bovines could possibly constitute an experimental model for approaches on UCB cells research.O sangue de cordão umbilical (SCU é uma importante fonte de células progenitoras pluripotentes, que motiva pesquisas em ontogenia e transplantes. A caracterização morfológica das células de cordão umbilical é o primeiro passo para se estabelecer experimentos subsequentes nessas áreas. Embora algumas informações sobre SCU em humanos possam ser encontradas, não existe nenhuma informação disponível sobre elas em bovinos. Portanto, este trabalho é a primeira tentativa de se conduzir uma caracterização ultra-estrutural do sangue de cordão umbilical

  14. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Butler, Philip J.; Sood, Shreya; Mojibian, Hamid; Tal, Michael G.

    2011-01-01

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History of PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71–3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.

  15. Different Angiogenic Potentials of Mesenchymal Stem Cells Derived from Umbilical Artery, Umbilical Vein, and Wharton’s Jelly

    Directory of Open Access Journals (Sweden)

    Lu Xu

    2017-01-01

    Full Text Available Human mesenchymal stem cells derived from the umbilical cord (UC are a favorable source for allogeneic cell therapy. Here, we successfully isolated the stem cells derived from three different compartments of the human UC, including perivascular stem cells derived from umbilical arteries (UCA-PSCs, perivascular stem cells derived from umbilical vein (UCV-PSCs, and mesenchymal stem cells derived from Wharton’s jelly (WJ-MSCs. These cells had the similar phenotype and differentiation potential toward adipocytes, osteoblasts, and neuron-like cells. However, UCA-PSCs and UCV-PSCs had more CD146+ cells than WJ-MSCs (P<0.05. Tube formation assay in vitro showed the largest number of tube-like structures and branch points in UCA-PSCs among the three stem cells. Additionally, the total tube length in UCA-PSCs and UCV-PSCs was significantly longer than in WJ-MSCs (P<0.01. Microarray, qRT-PCR, and Western blot analysis showed that UCA-PSCs had the highest expression of the Notch ligand Jagged1 (JAG1, which is crucial for blood vessel maturation. Knockdown of Jagged1 significantly impaired the angiogenesis in UCA-PSCs. In summary, UCA-PSCs are promising cell populations for clinical use in ischemic diseases.

  16. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  17. Use of Otoscope as a Diagnostic and Therapeutic Aid in Umbilical ...

    African Journals Online (AJOL)

    DISCUSSION. Umbilical pilonidal sinus is a rare entity as compared ... The theory of the acquired origin of umbilical pilonidal sinus was ... knowledge, this is the first study reporting the use of otoscope ... Financial support and sponsorship. Nil.

  18. Evaluation of home care management of umbilical cord stumps by ...

    African Journals Online (AJOL)

    Background: Umbilical cord care is an integral part of neonatal care in all communities and cultures and appropriate cord care reduces the risk of infection in the newborn infant. Objective: The present study assessed the home care management of the umbilical stump by the mothers at Ilesa, Southwestern Nigeria. Subjects ...

  19. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  20. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  1. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  2. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  3. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  4. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  5. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  6. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Trace of heavy metals in maternal and umbilical cord blood samples in association with birth outcomes in Baghdad, Iraq

    Science.gov (United States)

    Hasan Rhaif Al-Sahlanee, Mayyadah; Maizan Ramli, Ramzun; Abdul Hassan Ali, Miami; Fadhil Tawfiq, Nada; Zahirah Noor Azman, Nurul; Abdul Rahman, Azhar; Shahrim Mustafa, Iskandar; Noor Ashikin Nik Abdul Razak, Nik; Zakiah Yahaya, Nor; Mohammed Al-Marri, Hana; Syuhada Ayob, Nur; Zakaria, Nabela

    2017-10-01

    Trace elements are essential nutritional components in humans and inconvenient tissue content that have a significant influence on infant size. The aim of this study is to evaluate the effects of concentration of elements (uranium (U), lead (Pb) and iron (Fe)) and absorption of Pb and Fe on maternal and umbilical cord blood samples. The concentration and absorption of Pb and Fe in blood samples were determined by using atomic absorption spectrophotometry device, while the uranium concentration was determined by using CR-39 detector. Fifty women of age 16-44 years are involved in this study. Results show that the maximum and minimum values of both concentration and absorption in the maternal samples were for Pb and Fe, respectively. In addition, for umbilical cord, the maximum values of concentration and absorption were for Fe and the minimum concentration and absorption were for U and Pb, respectively. A significant correlation between maternal and umbilical cord blood samples was found. This indicates that the Pb, U and Fe elements can easily transfer from maternal to the fetal body which impacts the growth of fetus.

  8. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  9. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  10. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  11. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  12. Vitamin K1 levels in the umbilical cord blood of neonates in Arkhangelsk

    Directory of Open Access Journals (Sweden)

    L. G. Kiseleva

    2017-01-01

    Full Text Available The optimal course of biochemical processes needs adequate dietary intake of vitamins involved in the body’s metabolic reactions. The basis for the pathogenesis of neonatal hemorrhagic disease is deficiency of vitamin K, the level of which in the North-Western Region of Russia was estimated for the first time.Objective: to measure umbilical cord blood vitamin K1 levels in newborn infants.Methods. Forty full-term newborns were examined. Vitamin K1 levels were determined using high performance liquid chromatography-tandem mass spectrometry.Results. The mean umbilical blood cord level of vitamin K1 was very low and amounted to 0.05 (<0.03; 0.15 µg/l. This study revealed no relationship between the level of the above trace element and neonatal sex (p=0,854, maternal age (p=0,913, abortions (p=0,568, threatened abortion (p=0,109, smoking (p=0,923.Conclusion. The umbilical cord blood concentration of vitamin K1 in the newborns was found to be very low, which increases the risk of hemorrhagic disease and requires exogenous replenishment of the above vitamin after birth. 

  13. NAA for study of organohalogen levels in placenta, umbilical cord and hair of mothers with disabled newborns

    International Nuclear Information System (INIS)

    Zhang, H.; Chai, Z.F.; Chinese Academy of Sciences, Beijing; Wang, J.B.

    2008-01-01

    The concentrations of extractable organohalogens (EOX) and extractable persistent organohalogens (EPOX) in placenta, umbilical cord and hair of mothers delivering disabled or normal newborns as well as the compositions of EPOCl in three analyzed matrices were determined by a combination of NAA, gas chromatography and chemical separation. The results indicated that both EOX and EPOX decreased in the order: hair > umbilical cord > placenta. Organochlorines were the major fraction of organohalogens. More than 77% of EPOCl were unidentified. High organohalogens exposure may induce adverse health effects, and hair, as a biomonitor for organohalogens assessment, is more recommendable. (author)

  14. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  15. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  16. The relation between umbilical cord characteristics and the outcome of external cephalic version.

    Science.gov (United States)

    Kuppens, Simone M I; Waerenburgh, Evelyne R; Kooistra, Libbe; van der Donk, Riet W P; Hasaart, Tom H M; Pop, Victor J M

    2011-05-01

    Umbilical cords of fetuses in breech presentation differ in length and coiling from their cephalic counterparts and it might be hypothesised that these cord characteristics may in turn affect ECV outcome. To investigate the relation between umbilical cord characteristics and the outcome of external cephalic version (ECV). Prospective cohort study. Women (>35 weeks gestation) with a singleton fetus in breech presentation, suitable for external cephalic version. Demographic, lifestyle and obstetrical parameters were assessed at intake. ECV success was based on cephalic presentation on ultrasound post-ECV. Umbilical cord length (UCL) and umbilical coiling index (UCI) were measured after birth. The relation between umbilical cord characteristics (cord length and coiling) and the success of external cephalic version. ECV success rate was overall 79/146 (54%), for multiparas 37/46(80%) and for nulliparas 42/100 (42%). Multiple logistic regression showed that UCL (OR: 1.04, CI: 1.01-1.07), nulliparity (OR: 0.20, CI: 0.08-0.51), frank breech (OR: 0.37, 95% CI: 0.15-0.90), body mass index (OR: 0.85, CI: 0.76-0.95), placenta anterior (OR: 0.27, CI: 0.12-0.63) and birth weight (OR: 1.002, CI: 1.001-1.003) were all independently related to ECV success. Umbilical cord length is independently related to the outcome of ECV, whereas umbilical coiling index is not. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  18. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  19. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  20. ACCUMULATION OF SELECTED METALS IN UMBILICAL CORD BLOOD OF NULLIPAROUS AND MULTIPAROUS WOMEN AND CORRELATION WITH THE NEWBORN´S PARAMETERS

    Directory of Open Access Journals (Sweden)

    Iwona Kozikowska

    2012-08-01

    Full Text Available The aim of this study was to determine the content of magnesium, copper, cadmium and iron in umbilical cord blood of the newborns depending on the number of pregnancies. It was established correlations between average concentrations these metals in cord blood and newborn’s parameters. The study material was collected immediately after delivery from the Department of Obstetrics and Gynecology in Bytom. The cord blood was taken from 99 women between 29-40 years old. Women were divided into two groups: nulliparous and multiparous. The concentration of metals in the cord blood was determined by flame atomic absorption spectrometry (FAAS. The conducted study demonstrates that magnesium, copper, cadmium and iron were noted in all tissues, both nulliparous women and multiparous mothers. The maximum concentration of cadmium in umbilical cord blood was observed among multiparous mothers (2.229 mg.kg-1 d.m.. In group of nulliparous women was observed higher concentration of Fe, Mg and Cu in umbilical cord blood than in multiparous mothers. It was noted some statistically significant correlation between iron, copper and newborn’s parameters. Parity influences the concentration of cadmium in umbilical cord blood with higher level found in multiparous women. Average content of iron in cord blood did not decrease with parity, it indicate that this element is preferentially taken up by the child.

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  16. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  17. Amnioinfusion for umbilical cord compression in labour.

    Science.gov (United States)

    Hofmeyr, G J

    2000-01-01

    Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. The objective of this review was to assess the effects of amnioinfusion on maternal and perinatal outcome for potential or suspected umbilical cord compression or potential amnionitis. The Cochrane Pregnancy and Childbirth Group trials register and the Cochrane Controlled Trials Register were searched. Randomised trials of amnioinfusion compared with no amnioinfusion in women with babies at risk of umbilical cord compression; and women at risk of intrauterine infection. Eligibility and trial quality were assessed by the reviewer. Twelve studies were included. Transcervical amnioinfusion for potential or suspected umbilical cord compression was associated with the following reductions: fetal heart rate decelerations (relative risk 0.54, 95% confidence interval 0.43 to 0.68); caesarean section for suspected fetal distress (relative risk 0.35, 95% confidence interval 0.24 to 0.52); neonatal hospital stay greater than 3 days (relative risk 0.40, 95% confidence interval 0. 26 to 0.62); maternal hospital stay greater than 3 days (relative risk 0.46, 95% 0.29 to 0.74). Transabdominal amnioinfusion showed similar results. Transcervical amnioinfusion to prevent infection in women with membranes ruptured for more than 6 hours was associated with a reduction in puerperal infection (relative risk 0.50, 95% confidence interval 0.26 to 0.97). Amnioinfusion appears to reduce the occurrence of variable heart rate decelerations and lower the use of caesarean section. However the studies were done in settings where fetal distress was not confirmed by fetal blood sampling. The results may therefore only be relevant where caesarean sections are commonly done for abnormal fetal heart rate alone. The trials reviewed are too small to address the possibility of rare but serious maternal adverse effects of amnioinfusion.

  18. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  19. Estimation of the total number of mast cells in the human umbilical cord. A methodological study

    DEFF Research Database (Denmark)

    Engberg Damsgaard, T M; Windelborg Nielsen, B; Sørensen, Flemming Brandt

    1992-01-01

    The aim of the present study was to estimate the total number of mast cells in the human umbilical cord. Using 50 microns-thick paraffin sections, made from a systematic random sample of umbilical cord, the total number of mast cells per cord was estimated using a combination of the optical...... disector and fractionated sampling. The mast cell of the human umbilical cord was found in Wharton's jelly, most frequently in close proximity to the three blood vessels. No consistent pattern of variation in mast cell numbers from the fetal end of the umbilical cord towards the placenta was seen....... The total number of mast cells found in the umbilical cord was 5,200,000 (median), range 2,800,000-16,800,000 (n = 7), that is 156,000 mast cells per gram umbilical cord (median), range 48,000-267,000. Thus, the umbilical cord constitutes an adequate source of mast cells for further investigation...

  20. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  1. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  2. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  3. Phlebitis and infiltration: vascular trauma associated with the peripheral venous catheter

    Science.gov (United States)

    Braga, Luciene Muniz; Parreira, Pedro Miguel; Oliveira, Anabela de Sousa Salgueiro; Mónico, Lisete dos Santos Mendes; Arreguy-Sena, Cristina; Henriques, Maria Adriana

    2018-01-01

    ABSTRACT Objective: to determine the incidence rate and risk factors for the nursing-sensitive indicators phlebitis and infiltration in patients with peripheral venous catheters (PVCs). Method: cohort study with 110 patients. Scales were used to assess and document phlebitis and infiltration. Socio-demographic variables, clinical variables related to the PVC, medication and hospitalization variables were collected. Descriptive and inferential analysis and multivariate logistic models were used. Results: the incidence rate of phlebitis and infiltration was respectively 43.2 and 59.7 per 1000 catheter-days. Most PVCs with these vascular traumas were removed in the first 24 hours. Risk factors for phlebitis were: length of hospital stay (p=0.042) and number of catheters inserted (p<0.001); risk factors for infiltration were: piperacillin/tazobactan (p=0.024) and the number of catheters inserted (p<0.001). Conclusion: the investigation documented the incidence of nursing-sensitive indicators (phlebitis and infiltration) and revealed new risk factors related to infiltration. It also allowed a reflection on the nursing care necessary to prevent these vascular traumas and on the indications and contraindications of the PVC, supporting the implementation of the PICC as an alternative to PVC. PMID:29791668

  4. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  5. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  6. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  7. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  8. Catheter-based closure of the patent ductus arteriosus in lower weight infants.

    Science.gov (United States)

    Pavlek, Leeann R; Slaughter, Jonathan L; Berman, Darren P; Backes, Carl H

    2018-06-13

    Risks associated with drug therapy and surgical ligation have led health care providers to consider alternative strategies for patent ductus arteriosus (PDA) closure. Catheter-based PDA closure is the procedure of choice for ductal closure in adults, children, and infants ≥6kg. Given evidence among older counterparts, interest in catheter-based closure of the PDA in lower weight (closure devices; (3) review the technical success (feasibility); (4) review the risks (safety profile); (5) discuss the quality of evidence on procedural efficacy; (6) consider areas for future research. The review provided herein suggests that catheter-based PDA closure is technically feasible, but the lack of comparative trials precludes determination of the optimal strategy for ductal closure in this subgroup of infants. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  11. Fetal demise by umbilical cord around abdomen and stricture.

    Science.gov (United States)

    Tan, Shun-Jen; Chen, Chi-Huang; Wu, Gwo-Jang; Chen, Wei-Hwa; Chang, Cheng-Chang

    2010-01-01

    Umbilical cord abnormalities are accepted as conditions associated with intrauterine fetal demise (IUFD), and umbilical cord stricture is most frequently encountered. In addition, although cord entanglement with multiple loops rarely increases the perinatal mortality, it is associated with a significant increase in variable kind of morbidity such as growth restriction. We describe a 27-year-old woman, with a missed abortion history at about 10 weeks' gestation in her first pregnancy, who presented to our outpatient department at 34 4/7 weeks of gestation due to decreased fetal activity during the preceding week. No fetal heart activity and blood flow had been detected by ultrasonography and pulsed-wave Doppler. A demised fetus with umbilical cord stricture and three loops around abdomen was delivered and was weighted 1,830 g that was below the tenth percentile for the gestational age. Either umbilical cord stricture or entanglement around the body can affect the development of the fetus and even be lethal. The former might play a more important role in this case. Their etiology and the sequence of the events are still undetermined, and additional evaluation such as autopsy and further research may be needed. In addition, counsel and frequent fetal surveillance should be done in patients with previous IUFD attributed to cord stricture during next pregnancy because of undetermined risk of recurrence.

  12. Risk factors for reinsertion of urinary catheter after early removal in thoracic surgical patients.

    Science.gov (United States)

    Young, John; Geraci, Travis; Milman, Steven; Maslow, Andrew; Jones, Richard N; Ng, Thomas

    2018-03-08

    To reduce the incidence of urinary tract infection, Surgical Care Improvement Project 9 mandates the removal of urinary catheters within 48 hours postoperatively. In patients with thoracic epidural anesthesia, we sought to determine the rate of catheter reinsertion, the complications of reinsertion, and the factors associated with reinsertion. We conducted a prospective observational study of consecutive patients undergoing major pulmonary or esophageal resection with thoracic epidural analgesia over a 2-year period. As per Surgical Care Improvement Project 9, all urinary catheters were removed within 48 hours postoperatively. Excluded were patients with chronic indwelling catheter, patients with urostomy, and patients requiring continued strict urine output monitoring. Multivariable logistic regression analysis was used to identify independent risk factors for urinary catheter reinsertion. Thirteen patients met exclusion criteria. Of the 275 patients evaluated, 60 (21.8%) required reinsertion of urinary catheter. There was no difference in the urinary tract infection rate between patients requiring reinsertion (1/60 [1.7%]) versus patients not requiring reinsertion (1/215 [0.5%], P = .389). Urethral trauma during reinsertion was seen in 1 of 60 patients (1.7%). After reinsertion, discharge with urinary catheter was required in 4 of 60 patients (6.7%). Multivariable logistic regression analysis found esophagectomy, lower body mass index, and benign prostatic hypertrophy to be independent risk factors associated with catheter reinsertion after early removal in the presence of thoracic epidural analgesia. When applying Surgical Care Improvement Project 9 to patients undergoing thoracic procedures with thoracic epidural analgesia, consideration to delayed removal of urinary catheter may be warranted in patients with multiple risk factors for reinsertion. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Local perceptions, cultural beliefs and practices that shape umbilical cord care: a qualitative study in Southern Province, Zambia.

    Directory of Open Access Journals (Sweden)

    Julie M Herlihy

    Full Text Available Global policy regarding optimal umbilical cord care to prevent neonatal illness is an active discussion among researchers and policy makers. In preparation for a large cluster-randomized control trial to measure the impact of 4% chlorhexidine as an umbilical wash versus dry cord care on neonatal mortality in Southern Province, Zambia, we performed a qualitative study to determine local perceptions of cord health and illness and the cultural belief system that shapes umbilical cord care knowledge, attitudes, and practices.This study consisted of 36 focus group discussions with breastfeeding mothers, grandmothers, and traditional birth attendants, and 42 in-depth interviews with key community informants. Semi-structured field guides were used to lead discussions and interviews at urban and rural sites. A wide variation in knowledge, beliefs, and practices surrounding cord care was discovered. For home deliveries, cords were cut with non-sterile razor blades or local grass. Cord applications included drying agents (e.g., charcoal, baby powder, dust, lubricating agents (e.g., Vaseline, cooking oil, used motor oil and agents intended for medicinal/protective purposes (e.g., breast milk, cow dung, chicken feces. Concerns regarding the length of time until cord detachment were universally expressed. Blood clots in the umbilical cord, bulongo-longo, were perceived to foreshadow neonatal illness. Management of bulongo-longo or infected umbilical cords included multiple traditional remedies and treatment at government health centers.Umbilical cord care practices and beliefs were diverse. Dry cord care, as recommended by the World Health Organization at the time of the study, is not widely practiced in Southern Province, Zambia. A cultural health systems model that depicts all stakeholders is proposed as an approach for policy makers and program implementers to work synergistically with existing cultural beliefs and practices in order to maximize

  14. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  15. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  16. The relationship between maternal and neonatal umbilical cord plasma homocyst(e)ine suggests a potential role for maternal homocyst(e)ine in fetal metabolism.

    Science.gov (United States)

    Malinow, M R; Rajkovic, A; Duell, P B; Hess, D L; Upson, B M

    1998-02-01

    Data on fetal blood homocyst(e)ine concentrations are not available. We tested the hypothesis that homocyst(e)ine crosses the maternal/placental/fetal interphases and is sequestered by the fetus. The concentration of homocyst(e)ine was determined at parturition in peripheral venous plasma from 35 nulliparous healthy pregnant women and umbilical arterial and venous plasma from their conceptus. Findings demonstrated a descending concentration gradient of plasma homocyst(e)ine from maternal vein to umbilical vein and to umbilical artery; the decrease at each interphase approximated 1 micromol/L. The neonate weight and gestational age were inversely related to maternal homocyst(e)ine concentrations. The umbilical vein to umbilical artery homocyst(e)ine decrement suggests that uptake of homocyst(e)ine occurs in the fetus. The likely incorporation of homocyst(e)ine into the fetal metabolic cycle may implicate maternal homocyst(e)ine as having a potential nutritional role in the fetus. Further studies are required to explain the role of homocyst(e)ine in fetal metabolism and development.

  17. Short communication: The effect of 4 antiseptic compounds on umbilical cord healing and infection rates in the first 24 hours in dairy calves from a commercial herd.

    Science.gov (United States)

    Robinson, A L; Timms, L L; Stalder, K J; Tyler, H D

    2015-08-01

    The objective of this study was to compare the effect of 4 antiseptic compounds on the healing rate and incidence of infection of umbilical cords in newborn calves (n=60). Late gestation Jersey cows were monitored at a commercial farm (Sioux Jersey, Salix, IA) and newborn purebred (n=30) and crossbred (n=30) calves were obtained within 30min after birth. Calves were alternately assigned by birth order to 4 treatment groups: 7% tincture of iodine, 0.1% chlorine created using a novel chlorine disinfectant technology, chlorohexidine gluconate 4.0% wt/vol, and 10% trisodium citrate. Prior to dipping (within 30min of birth), diameter of the umbilical cords (as an indicator of cord drying and healing) were determined using digital calipers. In addition, as an indicator of umbilical infections, surface temperature of the umbilical stump (along with a reference point at the midpoint of the sternum) was determined using a dual-laser infrared thermometer. These measurements were all repeated at 24±1 h of age. All data were analyzed using mixed model methods. All models included fixed effects of breed (Jersey or Jersey cross), sex (bull or heifer), and treatment. Fixed effect interactions were not included in the statistical model due to the relatively small sample size. No treatment differences were noted for healing rate of umbilical cords. Initially, mean umbilical cord diameter was 22.84±3.89mm and cords healed to a mean diameter of 7.64±4.12mm at 24 h of age. No umbilical infections were noted for calves on any treatment during the course of this study. Mean surface temperature of the umbilical stump was 33.1±2.2°C at birth (1.5±1.6°C higher than the sternal reference temperature), and at 24±1 h of age the mean temperature of the umbilical stump was 33.0±4.3°C (0.5±1.8°C lower than the sternal reference temperature). These data suggest that these antiseptic compounds are equally effective for preventing infections and permitting healing of the umbilical cord

  18. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  19. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  20. Prevalence of infection in patients with temporary catheter for hemodialysis in a teaching hospital

    Directory of Open Access Journals (Sweden)

    Palmiane de Rezende Ramim Borges

    2017-08-01

    Full Text Available This study aimed to determine the prevalence of infection related to the provisional catheter for hemodialysis in a teaching hospital and evaluate the risk factors associated with these infections.  A cross-sectional study analyzed by descriptive statistics and parametric tests. It was found that out of 129 patients, 48.8 % had catheter-related infection in hemodialysis, 65 % were male, 33.3 % were 60 years old and over, and 88 % of patients were admitted to intensive care unit. The prevalence of infection in this group was high, and the vast majority of diagnoses of infection were empirical. Given this, it is suggested to establish the routine culture of the catheter tip in all cases of suspected catheter infection to improve the quality of patient care, and the relentless pursuit of the causes that trigger the infection process in line with good practice from across the healthcare team.

  1. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  4. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  5. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  6. Pacemaker implantation after catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  7. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  8. Peripheral intravenous and central catheter algorithm: a proactive quality initiative.

    Science.gov (United States)

    Wilder, Kerry A; Kuehn, Susan C; Moore, James E

    2014-12-01

    Peripheral intravenous (PIV) infiltrations causing tissue damage is a global issue surrounded by situations that make vascular access decisions difficult. The purpose of this quality improvement project was to develop an algorithm and assess its effectiveness in reducing PIV infiltrations in neonates. The targeted subjects were all infants in our neonatal intensive care unit (NICU) with a PIV catheter. We completed a retrospective chart review of the electronic medical record to collect 4th quarter 2012 baseline data. Following adoption of the algorithm, we also performed a daily manual count of all PIV catheters in the 1st and 2nd quarters 2013. Daily PIV days were defined as follows: 1 patient with a PIV catheter equals 1 PIV day. An infant with 2 PIV catheters in place was counted as 2 PIV days. Our rate of infiltration or tissue damage was determined by counting the number of events and dividing by the number of PIV days. The rate of infiltration or tissue damage was reported as the number of events per 100 PIV days. The number of infiltrations and PIV catheters was collected from the electronic medical record and also verified manually by daily assessment after adoption of the algorithm. To reduce the rate of PIV infiltrations leading to grade 4 infiltration and tissue damage by at least 30% in the NICU population. Incidence of PIV infiltrations/100 catheter days. The baseline rate for total infiltrations increased slightly from 5.4 to 5.68/100 PIV days (P = .397) for the NICU. We attributed this increase to heightened awareness and better reporting. Grade 4 infiltrations decreased from 2.8 to 0.83/100 PIV catheter days (P = .00021) after the algorithm was implemented. Tissue damage also decreased from 0.68 to 0.3/100 PIV days (P = .11). Statistical analysis used the Fisher exact test and reported as statistically significant at P < .05. Our findings suggest that utilization of our standardized decision pathway was instrumental in providing guidance for

  9. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  10. Cell therapy of congenital corneal diseases with umbilical mesenchymal stem cells: lumican null mice.

    Directory of Open Access Journals (Sweden)

    Hongshan Liu

    Full Text Available BACKGROUND: Keratoplasty is the most effective treatment for corneal blindness, but suboptimal medical conditions and lack of qualified medical personnel and donated cornea often prevent the performance of corneal transplantation in developing countries. Our study aims to develop alternative treatment regimens for congenital corneal diseases of genetic mutation. METHODOLOGY/PRINCIPAL FINDINGS: Human mesenchymal stem cells isolated from neonatal umbilical cords were transplanted to treat thin and cloudy corneas of lumican null mice. Transplantation of umbilical mesenchymal stem cells significantly improved corneal transparency and increased stromal thickness of lumican null mice, but human umbilical hematopoietic stem cells failed to do the same. Further studies revealed that collagen lamellae were re-organized in corneal stroma of lumican null mice after mesenchymal stem cell transplantation. Transplanted umbilical mesenchymal stem cells survived in the mouse corneal stroma for more than 3 months with little or no graft rejection. In addition, these cells assumed a keratocyte phenotype, e.g., dendritic morphology, quiescence, expression of keratocyte unique keratan sulfated keratocan and lumican, and CD34. Moreover, umbilical mesenchymal stem cell transplantation improved host keratocyte functions, which was verified by enhanced expression of keratocan and aldehyde dehydrogenase class 3A1 in lumican null mice. CONCLUSIONS/SIGNIFICANCE: Umbilical mesenchymal stem cell transplantation is a promising treatment for congenital corneal diseases involving keratocyte dysfunction. Unlike donated corneas, umbilical mesenchymal stem cells are easily isolated, expanded, stored, and can be quickly recovered from liquid nitrogen when a patient is in urgent need.

  11. Nationwide prospective study on readmission after umbilical or epigastric hernia repair

    DEFF Research Database (Denmark)

    Helgstrand, F; Jørgensen, L N; Rosenberg, J

    2013-01-01

    The primary aim of the present study was to investigate risk factors for readmission after elective umbilical and epigastric hernia repair and secondarily to evaluate causes for readmission.......The primary aim of the present study was to investigate risk factors for readmission after elective umbilical and epigastric hernia repair and secondarily to evaluate causes for readmission....

  12. Hypoxic ischemic encephalopathy in newborns linked to placental and umbilical cord abnormalities.

    Science.gov (United States)

    Nasiell, Josefine; Papadogiannakis, Nikos; Löf, Erika; Elofsson, Fanny; Hallberg, Boubou

    2016-03-01

    Birth asphyxia and hypoxic ischemic encephalopathy (HIE) of the newborn remain serious complications. We present a study investigating if placental or umbilical cord abnormalities in newborns at term are associated with HIE. A prospective cohort study of the placenta and umbilical cord of infants treated with hypothermia (HT) due to hypoxic brain injury and follow-up at 12 months of age has been carried out. The study population included 41 infants treated for HT whose placentas were submitted for histopathological analysis. Main outcome measures were infant development at 12 months, classified as normal, cerebral palsy, or death. A healthy group of 100 infants without HIE and normal follow-up at 12 months of age were used as controls. A velamentous or marginal umbilical cord insertion and histological abruption was associated with the risk of severe HIE, OR = 5.63, p = 0.006, respectively, OR = 20.3, p = 0.01 (multiple-logistic regression). Velamentous or marginal umbilical cord insertion was found in 39% among HIE cases compared to 7% in controls. Placental and umbilical cord abnormalities have a profound association with HIE. A prompt examination of the placentas of newborns suffering from asphyxia can provide important information on the pathogenesis behind the incident and contribute to make a better early prognosis.

  13. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  14. Ten-minute umbilical cord occlusion markedly reduces cerebral blood flow and heat production in fetal sheep.

    NARCIS (Netherlands)

    Lotgering, F.K.; Bishai, J.M.; Struijk, P.C.; Blood, A.B.; Hunter, C.J.; Power, G.G.; Longo, L.D.

    2003-01-01

    OBJECTIVE: The study was undertaken to determine to what extent a 10-minute total umbilical cord occlusion affects autoregulation of cerebral blood flow and cerebral heat production in the fetus. STUDY DESIGN: In seven chronically catheterized late-gestation fetal sheep (127-131 days' gestation), we

  15. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  16. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  17. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  18. Comparison of heparinized saline and 0.9% sodium chloride for maintaining peripheral intravenous catheter patency in dogs.

    Science.gov (United States)

    Ueda, Yu; Odunayo, Adesola; Mann, F A

    2013-01-01

    To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.

  19. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    Science.gov (United States)

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P phlebitis included pain (P phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  20. Central venous catheter-related bloodstream infections in cancer patients

    International Nuclear Information System (INIS)

    Butt, T.; Afzal, R.K.; Ahmad, R.N.; Hussain, I.; Anwar, M.

    2004-01-01

    Objective: To determine the frequency of central venous catheter-related bloodstream infections (CR-BSI) in cancer patients and the antimicrobial susceptibility pattern of the isolates. Subjects and Methods: Cancer patients requiring short or long-term central venous catheterization at the time of admission or thereafter were included. Catheter tips on removal were cultured quantitatively; specimens of blood and pus were cultured qualitatively. Isolates were identified and antimicrobial susceptibility testing was performed by standard techniques. Results: Eighty-nine patients were included in the study. The frequency of CR-BSI was 17%. Out of the 19 organisms isolated, 10 (53%) were Gram-positive cocci, 8 (42%) were Gram-negative rods and 1 (5%) was a fungus. Coagulase negative staphylococci (27%) were the predominant pathogens. Among the staphylococci, 46% of the isolates were methicillin-resistant. All Gram-positive isolates were susceptive to glycopeptides. Gram-negative rods were resistant to most of the commonly used antimicrobial groups. Conclusion: Central venous catheter is an important source of bloodstream infections in cancer patients. Most of the infections are caused by Gram-positive cocci. Rigorous infection control measures and continuous surveillance is required to curb the frequency of these infections. (author)

  1. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  2. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  3. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  4. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    Science.gov (United States)

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  5. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  6. Long-term follow-up results of umbilical hernia repair.

    Science.gov (United States)

    Venclauskas, Linas; Jokubauskas, Mantas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-12-01

    Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias ( 30 kg/m 2 , diabetes and wound infection were independent risk factors for umbilical hernia recurrence. The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m 2 , diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence.

  7. Emergency Department Catheter-Associated Urinary Tract Infection Prevention: Multisite Qualitative Study of Perceived Risks and Implemented Strategies.

    Science.gov (United States)

    Carter, Eileen J; Pallin, Daniel J; Mandel, Leslie; Sinnette, Corine; Schuur, Jeremiah D

    2016-02-01

    Existing knowledge of emergency department (ED) catheter-associated urinary tract infection (CAUTI) prevention is limited. We aimed to describe the motivations, perceived risks for CAUTI acquisition, and strategies used to address CAUTI risk among EDs that had existing CAUTI prevention programs. In this qualitative comparative case study, we enrolled early-adopting EDs, that is, those using criteria for urinary catheter placement and tracking the frequency of catheters placed in the ED. At 6 diverse facilities, we conducted 52 semistructured interviews and 9 focus groups with hospital and ED participants. All ED CAUTI programs originated from a hospitalwide focus on CAUTI prevention. Staff were motivated to address CAUTI because they believed program compliance improved patient care. ED CAUTI prevention was perceived to differ from CAUTI prevention in the inpatient setting. To identify areas of ED CAUTI prevention focus, programs examined ED workflow and identified 4 CAUTI risks: (1) inappropriate reasons for urinary catheter placement; (2) physicians' limited involvement in placement decisions; (3) patterns of urinary catheter overuse; and (4) poor insertion technique. Programs redesigned workflow to address risks by (1) requiring staff to specify the medical reason for catheter at the point of order entry and placement; (2) making physicians responsible for determining catheter use; (3) using catheter alternatives to address patterns of overuse; and (4) modifying urinary catheter insertion practices to ensure proper placement. Early-adopting EDs redesigned workflow to minimize catheter use and ensure proper insertion technique. Assessment of ED workflow is necessary to identify and modify local practices that may increase CAUTI risk.

  8. Severe Hemorrhage from the Umbilical Cord at Birth: A Preventable Cause of Neonatal Shock

    Directory of Open Access Journals (Sweden)

    Neetu Singh

    2013-01-01

    Full Text Available Posthemorrhagic anemia is a rare but important cause of anemia in neonates, second only to hemolytic anemia of newborn. Most cases of posthemorrhagic anemia are reported from fetomaternal hemorrhage or umbilical cord accidents in utero. This case report describes a preterm infant who developed severe anemia and shock immediately after delivery related to an acute hemorrhage through patent umbilical cord vessels secondary to a tear in the umbilical cord at the site of cord clamping. We believe that umbilical cord bleeding from errors in cord clamping could be an important cause of acute blood loss in the delivery room and that it may result in significant clinical morbidity, especially in extremely premature infants.

  9. Severe hemorrhage from the umbilical cord at birth: a preventable cause of neonatal shock.

    Science.gov (United States)

    Singh, Neetu; Suresh, Gautham

    2013-01-01

    Posthemorrhagic anemia is a rare but important cause of anemia in neonates, second only to hemolytic anemia of newborn. Most cases of posthemorrhagic anemia are reported from fetomaternal hemorrhage or umbilical cord accidents in utero. This case report describes a preterm infant who developed severe anemia and shock immediately after delivery related to an acute hemorrhage through patent umbilical cord vessels secondary to a tear in the umbilical cord at the site of cord clamping. We believe that umbilical cord bleeding from errors in cord clamping could be an important cause of acute blood loss in the delivery room and that it may result in significant clinical morbidity, especially in extremely premature infants.

  10. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  11. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  12. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  13. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  14. IN-VITRO EVALUATION OF BLOOD-FLOW THROUGH AUTOPERFUSION BALLOON CATHETERS

    NARCIS (Netherlands)

    DEMUINCK, ED; ANGELINI, P; DOUGHERTY, K; VERKERKE, BJ; RAKHORST, G; VANDIJK, RB; LIE, KI

    The effective flow rates with human blood through an autoperfusion catheter cannot be monitored in vivo and have not been experimentally determined in vitro. The manufacturers (Advanced Cardiovascular Systems [ACS], Temecula, CA) have suggested that ''the flow rate'' through the Stack(TM) over the

  15. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    Science.gov (United States)

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  16. Umbilical metastasis (Sister Mary Joseph's nodule diagnosed by fine-needle aspiration

    Directory of Open Access Journals (Sweden)

    Tatomirović Željka

    2004-01-01

    Full Text Available Sister Mary Joseph’s nodule is the eponym for metastatic involvement of the umbilicus. This less common entity is the sign of disseminated malignant disease, mainly of digestive and gynecologic origin, and is associated with a poor prognosis. A case of Sister Mary Joseph’s nodule in a 76-year-old woman in whom the umbilical metastasis was the first sign of malignant disease in presented. The diagnosis of metastatic adenocarcinoma was established by fine needle aspiration cytology of the umbilical nodule. Radiological and ultrasonographic investigation disclosed carcinoma of the gallbladder with pancreas, stomach, and colon invasion as well as peritoneal dissemination. The diagnosis was confirmed by exploratory laparatomy and histological examination of the excised umbilical nodule.

  17. Changing pattern of causative factors in development of umbilical infections (omphalitis) in newborns

    International Nuclear Information System (INIS)

    Nadeem, A.Z.; Malik, R.

    2010-01-01

    Despite the drastic decrease in the incidence of neonatal tetanus due to better aseptic techniques in cutting and tying of umbilical cord at birth, an increase in the prevalence of umbilical infections has been noticed. Objectives The objectives were to assess the ongoing practices in umbilical care, detect the prevailing causative factors responsible for umbilical infections in newborns and suggest measures for minimizing these infections. Design setting This descriptive study was a collaborative effort at CMH Nowshera, Mardan and Lahore from January 2007 through 2009. Patients and Methods Three hundred consecutive cases of umbilical sepsis ( omphalitis), infants less than 20 days old were included irrespective of place of delivery and severity of infection. Those with congenital anomalies of umbilicus were excluded. A detailed questionnaire was filled for every patient covering related aspects. Results Antisepsis (mainly spirit) was used in 91 % cases irrespective of place of delivery. Major tool for cutting the cord was surgical or new common blade (277 cases). Clamp was used in 138 cases. Cord was intentionally attended in subsequent weeks after birth in only 48 cases. Hand washing practice was found in only 62 parents in subsequent weeks after birth. Diapers were used in 261 cases, majority of these were found covering the umbilicus or umbilical stump when initially examined (81 %). 48% of infected unshed cords were more than 3 inches long. Use of unwarranted substances applied on cord was found in only 16 cases. (author)

  18. Postpartum deaths: piglet, placental, and umbilical characteristics.

    Science.gov (United States)

    Rootwelt, V; Reksen, O; Farstad, W; Framstad, T

    2013-06-01

    The fetal growth of the piglet is highly dependent on its placenta, and the newborn piglet birth weight is highly associated with postpartum death. However, there is little information available in the literature on the assessment of the placenta in relation to postpartum death in piglets. The aim of this study was to evaluate the impact of the placental area and placental weight, status of the umbilical cord, and piglet birth characteristics, such as blood parameters, vitality score, and birth weight on postpartum death. All live born piglets in litters from 26 Landrace-Yorkshire sows were monitored during farrowing and the status of each was recorded, including placental area and placental weight and blood variables obtained from the piglets and umbilical veins. Out of the 386 live-born piglets, 16.8% died before weaning at 5 wk. Among these, 78.5% died within the first 3 d of life. Mean blood concentration of lactate was increased in piglets that did not survive to weaning (P = 0.003). Concentrations of hemoglobin and hematocrit were decreased (P vitality score vs. piglets born with an intact umbilical cord (P = 0.021), and they had an increased probability of dying before weaning (P = 0.050). Mean birth weight, body mass index, placental area (P live litter size. Blood concentrations of IgG and albumin recorded at d 1 were decreased in piglets that died before weaning (P < 0.01), and blood concentration of albumin was positively associated with placental area (P < 0.001). We conclude that placental area and placental weight, status of the umbilical cord, birth weight, body mass index, blood concentrations of lactate, hemoglobin, and hematocrit recorded at birth, and blood concentrations of IgG and albumin recorded at d 1 were associated with postpartum death in this study. These results may indicate that there is an upper uterine limitation of litter size and that placental area and placental weight influence postpartum survival.

  19. Umbilical hernia rupture with evisceration of omentum from massive ascites: a case report

    LENUS (Irish Health Repository)

    Good, Daniel W

    2011-05-03

    Abstract Introduction The incidence of hernias is increased in patients with alcoholic liver disease with ascites. To the best of our knowledge, this is the first report of an acute rise in intra-abdominal pressure from straining for stool as the cause of a ruptured umbilical hernia. Case presentation An 81-year-old Caucasian man with a history of alcoholic liver disease presented to our emergency department with an erythematous umbilical hernia and clear, yellow discharge from the umbilicus. On straining for stool, after initial clinical assessment, our patient noted a gush of fluid and evisceration of omentum from the umbilical hernia. An urgent laparotomy was performed with excision of the umbilicus and devitalized omentum. Conclusion We report the case of a patient with a history of alcoholic liver disease with ascites. Ascites causes a chronic increase in intra-abdominal pressure. A sudden increase in intra-abdominal pressure, such as coughing, vomiting, gastroscopy or, as in this case, straining for stool can cause rupture of an umbilical hernia. The presence of discoloration, ulceration or a rapid increase in size of the umbilical hernia signals impending rupture and should prompt the physician to reduce the intra-abdominal pressure.

  20. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  1. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  2. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit.

    Science.gov (United States)

    Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee

    In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.

  4. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  5. In vitro cardiomyogenic potential of human umbilical vein-derived mesenchymal stem cells

    International Nuclear Information System (INIS)

    Kadivar, Mehdi; Khatami, Shohreh; Mortazavi, Yousef; Shokrgozar, Mohammad Ali; Taghikhani, Mohammad; Soleimani, Masoud

    2006-01-01

    Cardiomyocyte loss in the ischemically injured human heart often leads to irreversible defects in cardiac function. Recently, cellular cardiomyoplasty with mesenchymal stem cells, which are multipotent cells with the ability to differentiate into specialized cells under appropriate stimuli, has emerged as a new approach for repairing damaged myocardium. In the present study, the potential of human umbilical cord-derived mesenchymal stem cells to differentiate into cells with characteristics of cardiomyocyte was investigated. Mesenchymal stem cells were isolated from endothelial/subendothelial layers of the human umbilical cords using a method similar to that of human umbilical vein endothelial cell isolation. Isolated cells were characterized by transdifferentiation ability to adipocytes and osteoblasts, and also with flow cytometry analysis. After treatment with 5-azacytidine, the human umbilical cord-derived mesenchymal stem cells were morphologically transformed into cardiomyocyte-like cells and expressed cardiac differentiation markers. During the differentiation, cells were monitored by a phase contrast microscope and their morphological changes were demonstrated. Immunostaining of the differentiated cells for sarcomeric myosin (MF20), desmin, cardiac troponin I, and sarcomeric α-actinin was positive. RT-PCR analysis showed that these differentiated cells express cardiac-specific genes. Transmission electron microscopy revealed a cardiomyocyte-like ultrastructure and typical sarcomers. These observations confirm that human umbilical cord-derived mesenchymal stem cells can be chemically transformed into cardiomyocytes and can be considered as a source of cells for cellular cardiomyoplasty

  6. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.

  7. Umbilical cord blood lactate: a valuable tool in the assessment of fetal metabolic acidosis

    DEFF Research Database (Denmark)

    Gjerris, Anne Cathrine Roslev; Staer-Jensen, Jette; Jørgensen, Jan Stener

    2008-01-01

    The aim of the present study was (1) to evaluate the relationship between umbilical cord arterial blood lactate and pH, standard base excess (SBE), and actual base excess (ABE) at delivery and (2) to suggest a cut-off level of umbilical cord arterial blood lactate in predicting fetal asphyxia usi...... ROC-curves, where an ABE value less than -12 was used as "gold standard" for significant intrapartum asphyxia.......The aim of the present study was (1) to evaluate the relationship between umbilical cord arterial blood lactate and pH, standard base excess (SBE), and actual base excess (ABE) at delivery and (2) to suggest a cut-off level of umbilical cord arterial blood lactate in predicting fetal asphyxia using...

  8. Impact of ethanol, dry care and human milk on the time for umbilical cord separation

    International Nuclear Information System (INIS)

    Golshan, M.; Hossein, N.

    2013-01-01

    Objective: To compare the extraction time and infection rate of umbilical cord by applying ethanol, human milk or dry care. Method: The parallel single-blinded randomised clinical trial was performed on 300 neonates at Shahid Sadougi University of Medical Sciences and Health Service, Yazd, Iran, between March and September 2010. The neonates were divided into three random but numerically equal groups. Each group was assigned the application of ethanol or mother's milk or to keep the stump dry. The neonates were visited on the 3rd and the 7th day after birth and follow-up was maintained telephonically until umbilical separation. Umbilical separation time and umbilical local infection frequency were considered as the study outcome, which was compared among the three groups according to age, gender and delivery type of the neonates. Results: Umbilical separation time in neonates of the human milk group had significant difference with the ethanol group (p=0.0001) and drying groups (p=0.003). Frequency of omphalitis had no significant difference among the three groups. Conclusion: Topical usage of human milk on umbilical cord stamp decreased separation time and incidence rate of omphalitis. (author)

  9. Severe Hemorrhage from the Umbilical Cord at Birth: A Preventable Cause of Neonatal Shock

    OpenAIRE

    Singh, Neetu; Suresh, Gautham

    2013-01-01

    Posthemorrhagic anemia is a rare but important cause of anemia in neonates, second only to hemolytic anemia of newborn. Most cases of posthemorrhagic anemia are reported from fetomaternal hemorrhage or umbilical cord accidents in utero. This case report describes a preterm infant who developed severe anemia and shock immediately after delivery related to an acute hemorrhage through patent umbilical cord vessels secondary to a tear in the umbilical cord at the site of cord clamping. We believe...

  10. Umbilical Hernia Repair and Pregnancy: Before, during, after…

    Directory of Open Access Journals (Sweden)

    Hakan Kulacoglu

    2018-01-01

    Full Text Available Umbilical hernias are most common in women than men. Pregnancy may cause herniation or render a preexisting one apparent, because of progressively raised intra-abdominal pressure. The incidence of umbilical hernia among pregnancies is 0.08%. Surgical algorithm for a pregnant woman with a hernia is not thoroughly clear. There is no consensus about the timing of surgery for an umbilical hernia in a woman either who is already pregnant or planning a pregnancy. If the hernia is incarcerated or strangulated at the time of diagnosis, an emergency repair is inevitable. If the hernia is not complicated, but symptomatic an elective repair should be proposed. When the patient has a small and asymptomatic hernia it may be better to postpone the repair until she gives birth. If the hernia is repaired by suture alone, a high risk of recurrence exists during pregnancy. Umbilical hernia repair during pregnancy can be performed with minimal morbidity to the mother and baby. Second trimester is a proper timing for surgery. Asymptomatic hernias can be repaired, following childbirth or at the time of cesarean section (C-section. Elective repair after childbirth is possible as early as postpartum of eighth week. A 1-year interval can give the patient a very smooth convalescence, including hormonal stabilization and return to normal body weight. Moreover, surgery can be postponed for a longer time even after another pregnancy, if the patients would like to have more children. Diastasis recti are very frequent in pregnancy. It may persist in postpartum period. A high recurrence risk is expected in patients with rectus diastasis. This risk is especially high after suture repairs. Mesh repairs should be considered in this situation.

  11. Amino acid composition of parturient plasma, the intervillous space of the placenta and the umbilical vein of term newborn infants

    Directory of Open Access Journals (Sweden)

    J.S. Camelo Jr.

    2004-05-01

    Full Text Available The objective of the present study was to determine the levels of amino acids in maternal plasma, placental intervillous space and fetal umbilical vein in order to identify the similarities and differences in amino acid levels in these compartments of 15 term newborns from normal pregnancies and deliveries. All amino acids, except tryptophan, were present in at least 186% higher concentrations in the intervillous space than in maternal venous blood, with the difference being statistically significant. This result contradicted the initial hypothesis of the study that the plasma amino acid levels in the placental intervillous space should be similar to those of maternal plasma. When the maternal venous compartment was compared with the umbilical vein, we observed values 103% higher on the fetal side which is compatible with currently accepted mechanisms of active amino acid transport. Amino acid levels of the placental intervillous space were similar to the values of the umbilical vein except for proline, glycine and aspartic acid, whose levels were significantly higher than fetal umbilical vein levels (average 107% higher. The elevated levels of the intervillous space are compatible with syncytiotrophoblast activity, which maintain high concentrations of free amino acids inside syncytiotrophoblast cells, permitting asymmetric efflux or active transport from the trophoblast cells to the blood in the intervillous space. The plasma amino acid levels in the umbilical vein of term newborns probably may be used as a standard of local normality for clinical studies of amino acid profiles.

  12. Umbilical cord-care practices in low- and middle-income countries: a systematic review

    Directory of Open Access Journals (Sweden)

    Patricia S. Coffey

    2017-02-01

    Full Text Available Abstract Background Neonatal sepsis is the third leading cause of deaths for infants in their first month of life. The newly cut umbilical cord can be a pathway for bacteria that can cause newborn sepsis and death. Optimal umbilical cord care practices for newborns and during the first week of life, especially in settings with poor hygiene, has the potential to avoid these preventable neonatal deaths. The purpose of this review of cord care practices is to assist in the development of behavior-change strategies to support introduction of novel cord-care regimens, particularly 7.1% chlorhexidine digluconate for umbilical cord care. Methods We searched domestic and international databases for articles that were published in English between January 1, 2000, and August 24, 2016. We found 321 articles and reviewed 65 full-text articles using standardized inclusion criteria. The primary criteria for inclusion was a description of substances applied to the umbilical cord stump in the days following birth. Results We included 46 articles in this review of umbilical cord-care practices. Articles included data from 15 low- and middle-income countries in sub-Saharan Africa (8 countries, Asia (5 countries, North Africa (1 country, and Latin America and the Caribbean (1 country. Findings from this review suggest that documentation of cord-care practices is not consistent throughout low- and middle-income countries, yet existing literature depicts a firm tradition of umbilical cord care in every culture. Cord-care practices vary by country and by regions or cultural groups within a country and employ a wide range of substances. The desire to promote healing and hasten cord separation are the underlying beliefs related to application of substances to the umbilical cord. The frequency of application of the substance (either the number of days or the number of times per day the substance was applied, and source and cost of products used is not well

  13. Stem cells of umbilical blood cord – therapeutic use

    Directory of Open Access Journals (Sweden)

    Beata Bielec

    2015-07-01

    Full Text Available For many years, the transplantation of hematopoietic stem cells has been used to treat some diseases of the hematopoietic system. For a very long time, only bone marrow was used as a source of hematopoietic stem cells for this method of treatment. However, to comply with allogeneic bone marrow transplantation, an antigenically compatible donor is necessary. Transplantations from unrelated donors are associated with increased risk of a graft-versus-host reaction, transplant rejection and, consequently, increased mortality. Many years ago, it was found that umbilical cord blood as well as bone marrow and peripheral blood contains hematopoietic stem cells and mesenchymal cells able to differentiate into different cell types and that the umbilical cord blood can be a source of stem cells for transplantation. Following this discovery, numerous attempts were made for its potential use in the treatment of hematologic diseases, metabolic diseases as well as regenerative medicine. Umbilical cord blood stem cells exhibit intermediate characteristics between embryonic and adult stem cells. They are distinguished from the latter by telomere length, telomerase activity, and lower risk of accumulation of DNA mutations or chromosomal aberrations. The only transplantation limitation appears to be the amount of cord blood collected, which on average is sufficient for transplantation in a 40-50 kg child. Collection of cord blood is a simple, short-lasting treatment, not causing any danger for a newborn or the mother. Umbilical cord blood is obtained during labor, and then frozen and stored at cord blood banks all over the world.

  14. First reported case of Staphylococcus condimenti infection associated with catheter-related bacteraemia

    Directory of Open Access Journals (Sweden)

    Y. Misawa

    2015-01-01

    Full Text Available We report a case of a patient who experienced a catheter-related bloodstream infection caused by Staphylococcus condimenti, which was first isolated from soy sauce mash. This is the first reported case of human infection. Although blood culture isolates and the catheter tip tube did not reveal coagulase or clumping factor, false-positive results were obtained from latex agglutination tests for clumping factor and protein A due to self-agglutination. Care is needed when performing only latex agglutination test without a coagulase test. Further studies are needed to determine the pathogenic potential of S. condimenti based on appropriate identification.

  15. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  16. Metabolomic profiling in blood from umbilical cords of low birth weight newborns

    Directory of Open Access Journals (Sweden)

    Ivorra Carmen

    2012-07-01

    Full Text Available Abstract Background Low birth weight has been linked to an increased risk to develop obesity, type 2 diabetes, and hypertension in adult life, although the mechanisms underlying the association are not well understood. The objective was to determine whether the metabolomic profile of plasma from umbilical cord differs between low and normal birth weight newborns. Methods Fifty healthy pregnant women and their infants were selected. The eligibility criteria were being born at term and having a normal pregnancy. Pairs were grouped according to their birth weight: low birth weight (LBW, birth weight th percentile, n = 20 and control (control, birth weight between the 75th-90th percentiles, n = 30. Nuclear Magnetic Resonance (NMR was used to generate metabolic fingerprints of umbilical cord plasma samples. Simultaneously, the metabolomic profiles of the mothers were analysed. The resulting data were subjected to chemometric, principal component and partial least squares discriminant analyses. Results Umbilical cord plasma from LBW and control newborns displayed a clearly differentiated metabolic profile. Seven metabolites were identified that discriminate the LBW from the control group. LBW newborns had lower levels of choline, proline, glutamine, alanine and glucose than did the control newborns, while plasma levels of phenylalanine and citrulline were higher in LBW newborns (p Conclusions Low birth weight newborns display a differential metabolomic profile than those of normal birth weight, a finding not present in the mothers. The meaning and the potential utility of the findings as biomarkers of risk need to be addressed in future studies.

  17. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  18. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  19. Attitudes of Swiss mothers toward unrelated umbilical cord blood banking 6 months after donation.

    Science.gov (United States)

    Danzer, Enrico; Holzgreve, Wolfgang; Troeger, Carolyn; Kostka, Ulrike; Steimann, Sabine; Bitzer, Johanes; Gratwohl, Alois; Tichelli, André; Seelmann, Kurt; Surbek, Daniel V

    2003-05-01

    During the past decade, the use of umbilical cord blood (CB) as a source of transplantable hematopoietic stem cells has been increasing. Little is known about the psychosocial consequences that later affect parents after unrelated CB donation. The objective of this study was to evaluate the attitudes of mothers toward unrelated donation of umbilical CB for transplantation 6 months after giving birth. A prospective study was performed with a standardized, anonymous questionnaire distributed to 131 women 6 months after CB donation. The questionnaire included topics concerning views about the ethical accuracy of having donated CB, emotional responses after donation, concerns about genetic testing and research with CB samples, attitude toward anonymity between her child and possible unrelated CB recipient, and willingness to repeatedly donate umbilical CB in a next pregnancy. The vast majority (96.1%) stated that they would donate umbilical CB again, and all respondents were certain that their decision to have donated umbilical CB was ethical. With regard to the potential risks of genetic testing and "experimentation" of umbilical CB, a significant correlation (p = 0.01) was found between negative attitudes and the decision not to donate umbilical CB again. Additionally, it was observed that women who had a negative experience concerning the donation of CB would not donate again (p = 0.004). This study shows a high degree of satisfaction of unrelated umbilical CB donation for banking in women 6 months after delivery. Despite a well-performed and detailed informed consent procedure, one of the ongoing issues for the donators in CB banking involves the concern regarding of improper use of the cells, such as genetic testing or experimentation. Accurate and detailed counseling of pregnant women and their partners therefore maximizes the likelihood that they will donate CB for unrelated banking. These data provide a basis for the improvement of donor selection procedures

  20. Policies for replacing long-term indwelling urinary catheters in adults.

    Science.gov (United States)

    Cooper, Fergus P M; Alexander, Cameron Edwin; Sinha, Sanjay; Omar, Muhammad Imran

    2016-07-26

    Long-term indwelling catheters are used commonly in people with lower urinary tract problems in home, hospital and specialised health-care settings. There are many potential complications and adverse effects associated with long-term catheter use. The effect of health-care policies related to the replacement of long-term urinary catheters on patient outcomes is unclear. To determine the effectiveness of different policies for replacing long-term indwelling urinary catheters in adults. We searched the Cochrane Incontinence Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 19 May 2016), and the reference lists of relevant articles. All randomised controlled trials investigating policies for replacing long-term indwelling urinary catheters in adults were included. At least two review authors independently performed data extraction and assessed risk of bias of all the included trials. Quality of evidence was assessed by adopting the GRADE approach. Any discrepancies were resolved by discussion between the review authors or an independent arbitrator. We contacted the authors of included trials to seek clarification where required. Three trials met the inclusion criteria, with a total of 107 participants in three different health-care settings: A USA veterans administration nursing home; a geriatric centre in Israel; and a community nursing service in Hong Kong. Data were available for three of the pre-stated comparisons. Priefer and colleagues evaluated different time intervals between catheter replacement (n = 17); Firestein and colleagues evaluated the use of antibiotic prophylaxis at the time of replacement (n = 70); and Cheung and colleagues compared two different types of cleaning solutions (n = 20).All the included trials were

  1. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    International Nuclear Information System (INIS)

    Anfinsen, Ole-Gunnar

    1999-01-01

    the delivery of RF current in the right atrial free wall. Lung lesions were particularly deep in unipolar 10 mm ablation, because lesion length and depth increased proportionately. Sudden impedance rise most frequently was observed with the bipolar two-catheter technique and was never observed in the dielectrode mode when the power limit was 50 W. 3) When choosing a set temperature for temperature controlled ablations it is important to consider both the location of the thermo sensor in the ablation electrode, the most probable catheter up-tissue orientation at the target of ablation and the estimated local flow (=convective heat loss). 4) In patients subjected to RF ablation, the procedure duration prior to heparin administration and not the delivery of RF current per se, determines activation of haemostasis and fibrinolysis. Some future perspectives are mentioned

  2. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    Energy Technology Data Exchange (ETDEWEB)

    Anfinsen, Ole-Gunnar

    1999-07-01

    related to the delivery of RF current in the right atrial free wall. Lung lesions were particularly deep in unipolar 10 mm ablation, because lesion length and depth increased proportionately. Sudden impedance rise most frequently was observed with the bipolar two-catheter technique and was never observed in the dielectrode mode when the power limit was 50 W. 3) When choosing a set temperature for temperature controlled ablations it is important to consider both the location of the thermo sensor in the ablation electrode, the most probable catheter up-tissue orientation at the target of ablation and the estimated local flow (=convective heat loss). 4) In patients subjected to RF ablation, the procedure duration prior to heparin administration and not the delivery of RF current per se, determines activation of haemostasis and fibrinolysis. Some future perspectives are mentioned.

  3. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  4. Questionable validity of the catheter-associated urinary tract infection metric used for value-based purchasing.

    Science.gov (United States)

    Calderon, Lindsay E; Kavanagh, Kevin T; Rice, Mara K

    2015-10-01

    Catheter-associated urinary tract infections (CAUTIs) occur in 290,000 US hospital patients annually, with an estimated cost of $290 million. Two different measurement systems are being used to track the US health care system's performance in lowering the rate of CAUTIs. Since 2010, the Agency for Healthcare Research and Quality (AHRQ) metric has shown a 28.2% decrease in CAUTI, whereas the Centers for Disease Control and Prevention metric has shown a 3%-6% increase in CAUTI since 2009. Differences in data acquisition and the definition of the denominator may explain this discrepancy. The AHRQ metric analyzes chart-audited data and reflects both catheter use and care. The Centers for Disease Control and Prevention metric analyzes self-reported data and primarily reflects catheter care. Because analysis of the AHRQ metric showed a progressive change in performance over time and the scientific literature supports the importance of catheter use in the prevention of CAUTI, it is suggested that risk-adjusted catheter-use data be incorporated into metrics that are used for determining facility performance and for value-based purchasing initiatives. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Placental disease and abnormal umbilical artery Doppler waveforms in trisomy 21 pregnancy: A case-control study.

    Science.gov (United States)

    Corry, Edward; Mone, Fionnuala; Segurado, Ricardo; Downey, Paul; McParland, Peter; McAuliffe, Fionnuala M; Mooney, Eoghan E

    2016-11-01

    The objectives of this study were firstly to determine the proportion of placental pathology in fetuses affected by trisomy 21 (T21) using current pathological descriptive terminology and secondly to examine if a correlation existed between the finding of an abnormal umbilical artery Doppler (UAD) waveform, the presence of T21 and defined placental pathological categories. This case-control study assessed singleton fetuses with karyotypically confirmed trisomy 21 where placental histopathology had been conducted from 2003 to 2015 inclusive, within a university tertiary obstetric centre. This was compared with unselected normal singleton control pregnancies matched within a week of gestation at delivery. Data included birthweight centiles and placental histopathology. Comparisons of Doppler findings across placental pathological categories were performed using statistical analysis. 104 cases were analysed; 52 cases of trisomy 21 and 52 controls. Fetal vascular malperfusion (48.1% vs. 5.8%, p = 0.001) and maturation defects (39.2% vs. 15.7%, p = 0.023) were more common in trisomy 21 placentas. Compared with controls, trisomy 21 fetuses were more likely to have shorter umbilical cords (p = 0.001) and had more UAD abnormalities. Amongst T21 pregnancies, umbilical artery Doppler abnormalities are associated with the presence of maternal vascular malperfusion. Fetal vascular malperfusion and maturation defects are more common in trisomy 21 placentas. Abnormal umbilical artery Doppler waveforms are more common in T21 and are associated with maternal vascular malperfusion. Placental disease may explain the increased rate of intrauterine death in T21. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  8. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  9. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    Science.gov (United States)

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  10. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  11. Translumbar aortography by catheter technique

    International Nuclear Information System (INIS)

    Hagen, B.; Honemeyer, U.; Meier-Duis, H.

    1982-01-01

    400 examinations performed during the last three years by TLA (only catheter technique) were subjected to critical analysis and studied particularly in respect to the rate of complications. We observed 13 complications (3.25%) of moderate severity, including 3 large hematomas (documented by CT), 3 paravasations and 7 dissections, but no fatal complication. Two (0.5%) of these complications had clinical evidence. The advantages of the catheter technique of TLA are described. Injections through rigid metal cannula should be avoided because of the high incidence of complications (mainly the increased risk of dissection). Downstream injection resulted in excellent visualization of peripheral occluding vascular disease. Upstream injection should be preferred to demonstrate the major abdominal arteries as well as supraceliac collateral circulation in the case of high Leriche syndrome. The low or intermediate puncture of the aorta is preferable to facilitate caudad direction of the catheter and to diminish the risk of damaging other vessels or puncturing an organ. (orig.) [de

  12. Catheter-associated UTI

    Science.gov (United States)

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  13. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  14. Use of urethral catheters for diagnostic peritoneal lavage in blunt ...

    African Journals Online (AJOL)

    Background: Diagnostic peritoneal lavage (DPL) has been reported to be a reliable diagnostic tool in assessing the need for liparotomy in blunt abdominal trauma (BAT) with a diagnostic accuracy of more thin 95% when using a peritoneal lavage catheter (PLC). The aim of this study was to determine the diagnostic ...

  15. Computed tomography-guided percutaneous catheter drainage of primary and secondary iliopsoas abscesses

    International Nuclear Information System (INIS)

    Cantasdemir, M.; Kara, B.; Cebi, D.; Selcuk, N.D.; Numan, F.

    2003-01-01

    AIM: To report our experience with computed tomography (CT)-guided percutaneous catheter drainage (PCD) of iliopsoas abscesses. MATERIALS AND METHODS: Twenty-two iliopsoas abscesses in 21 patients (11 women, 10 men) aged between 18 and 66 years (mean 36 years) were treated with PCD. Abdominal CT demonstrated the iliopsoas abscesses, which were definitively determined by Gram staining and aspirate cultures. Twenty of the 22 iliopsoas abscesses were primary and two were secondary. All PCD procedures were performed under local anaesthesia using a single-step trocar technique (n=19) or Seldinger technique (n=3). RESULTS: PCD was an effective treatment in 21 out of the 22 iliopsoas abscesses. Recurrence was seen in three abscesses as minimal residual collections. Two of them resolved spontaneously with anti-tuberculous regimen. One required percutaneous needle aspiration. The procedure failed in a diabetic patient with a secondary abscess, who died due to sepsis. The length of time that catheters remained in place ranged from 21 to 75 days (mean 59.7 days). Complications included catheter dislocation in four abscesses, which required removal of dislocated catheters and indwelling new ones. CONCLUSION: CT-guided PCD is a safe and effective front-line treatment of iliopsoas abscesses. Surgery should be reserved for failure of PCD and presence of contraindications to PCD

  16. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  17. Pigtail Catheter: A Less Invasive Option for Pleural Drainage in Egyptian Patients with Recurrent Hepatic Hydrothorax

    Directory of Open Access Journals (Sweden)

    Mohamed Sharaf-Eldin

    2016-01-01

    Full Text Available Background and Aims. Treatment of hepatic hydrothorax is a clinical challenge. Chest tube insertion for hepatic hydrothorax is associated with high complication rates. We assessed the use of pigtail catheter as a safe and practical method for treatment of recurrent hepatic hydrothorax as it had not been assessed before in a large series of patients. Methods. This study was conducted on 60 patients admitted to Tanta University Hospital, Egypt, suffering from recurrent hepatic hydrothorax. The site of pigtail catheter insertion was determined by ultrasound guidance under complete aseptic measures and proper local anesthesia. Insertion was done by pushing the trocar and catheter until reaching the pleural cavity and then the trocar was withdrawn gradually while inserting the catheter which was then connected to a collecting bag via a triple way valve. Results. The use of pigtail catheter was successful in pleural drainage in 48 (80% patients with hepatic hydrothorax. Complications were few and included pain at the site of insertion in 12 (20% patients, blockage of the catheter in only 2 (3.3% patients, and rapid reaccumulation of fluid in 12 (20% patients. Pleurodesis was performed on 38 patients with no recurrence of fluid within three months of observation. Conclusions. Pigtail catheter insertion is a practical method for treatment of recurrent hepatic hydrothorax with a low rate of complications. This trial is registered with ClinicalTrials.gov Identifier: NCT02119169.

  18. Good practices in collecting umbilical cord and placental blood.

    Science.gov (United States)

    Lopes, Lauren Auer; Bernardino, Elizabeth; Crozeta, Karla; Guimarães, Paulo Ricardo Bittencourt

    2016-08-18

    to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1) verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2) definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r) and R(r). while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality. identificar fatores relacionados à qualidade das amostras do sangue de cordão umbilical e placentário e definir boas práticas para sua coleta em um banco público de sangue de cordão umbilical e placentário. pesquisa descritiva, abordagem quantitativa, realizada em um banco público de sangue de cordão umbilical e placentário, desenvolvida em duas etapas: 1) verificação dos fatores obstétricos, neonatais e operacionais, obtidos por coleta em instrumento próprio e observação não participante; 2) definição das boas práticas, por meio do agrupamento de não-conformidades observadas antes, durante e após a coleta do sangue. Os dados foram analisados por meio da estatística descritiva, utilizando-se dos softwares Statistica(r) e R(r). houve

  19. Percutaneous untying of a knot in a retained Swan-Ganz catheter

    International Nuclear Information System (INIS)

    Bhatti, Waqar A.; Sinha, Sankar; Rowlands, Peter

    2000-01-01

    A patient was referred to us with a tightly knotted Swan-Ganz catheter. The catheter could not be removed by conventional simple methods. We describe a minimally invasive means of removal of the catheter using an Amplatz gooseneck snare and an angioplasty balloon. This allowed the Catheter to be removed without trauma.

  20. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods...... to infection were measured. After catheter insertion, all patients were screened for nasal carriage of S. aureus, and a culture was taken from the skin overlying the catheter insertion site. Once a week, cultures were taken from the insertion site and from the hub, and aerobic and anaerobic blood cultures were...... drawn from the catheter. If clinical signs of septicaemia occurred, peripheral blood cultures were also performed, when it was possible. RESULTS: The incidence of septicaemia was 49% (21/43) in patients, and 56% of all cases were caused by S. aureus. The mortality was 14% (3/21) and the incidence...

  1. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  2. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    Science.gov (United States)

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  3. Associations between intrapartum death and piglet, placental, and umbilical characteristics.

    Science.gov (United States)

    Rootwelt, V; Reksen, O; Farstad, W; Framstad, T

    2012-12-01

    Intrapartum death in multiparous gestations in sows (Sus scrofa) is often caused by hypoxia. There is little information in the literature on the assessment of the placenta in relation to intrapartum death in piglets. The aim of this study was to evaluate the impact of the placental area and weight upon piglet birth characteristics and intrapartum death. Litters from 26 Landrace-Yorkshire sows were monitored during farrowing and the status of each piglet was recorded, including blood parameters of piglets and their umbilical veins. Of 413 piglets born, 6.5% were stillborn. Blood concentrations of glucose, lactate, and CO(2) partial pressure were increased in the stillborn piglets (P birth was increased for piglets born dead vs. live (P birth weight for piglets born dead was not different from live-born piglets (P = 0.631), whereas mean body mass index was reduced (P 0.2). Piglet BW was positively correlated with placental area and placental weight (P birth order group, and broken umbilical cords explained 71% of the stillbirths (P = 0.001). We conclude that placental area and placental weight are both positively associated with piglet birth weight, but not with the probability of being born dead. Placental area was a better predictor of piglet vitality than placental weight. Because umbilical cord rupture and prolonged birth time were associated with being born dead, umbilical cord rupture and placental detachment seem to be probable causes of intrapartum death.

  4. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  5. Good practices in collecting umbilical cord and placental blood

    Directory of Open Access Journals (Sweden)

    Lauren Auer Lopes

    Full Text Available Abstract Objective: to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. Method: this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1 verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2 definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r and R(r. Results: while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. Conclusion: the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality.

  6. Embolization of brain arteriovenous malformations using tracker catheter

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Son, Mi Young; Jang, Jae Chun; Hwang, Mi Soo; Park, Bok Hwan

    1990-01-01

    With the recent advance in micro catheters, steerable guide wires, balloons, embolic materials and digital subtraction angiography (DSA), as well as technical refinements in endovascular surgery, there has been a revolution in therapeutic strategies for cerebral arteriovenous malformations (AVMs). We have performed super selective angiography and embolization with Tracker micro catheter about 12 cases of brain AVMs for therapeutic and preoperative aims. This micro catheter and guide wire provided high selectivity of feeding artery, greater maneuverability and useful for deliver various embolus materials

  7. Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial.

    Science.gov (United States)

    Zehnder, Pascal; Roth, Beat; Burkhard, Fiona C; Kessler, Thomas M

    2008-09-01

    We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

  8. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  9. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate......We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...

  10. Microbial load of umbilical cord blood Ureaplasma species and Mycoplasma hominis in preterm prelabor rupture of membranes.

    Science.gov (United States)

    Kacerovsky, Marian; Pliskova, Lenka; Menon, Ramkumar; Kutova, Radka; Musilova, Ivana; Maly, Jan; Andrys, Ctirad

    2014-11-01

    To evaluate Ureaplasma species and M. hominis DNA in the umbilical cord blood and its correlation with its microbial load in the amniotic fluid, as a measure of microbial burden in fetal inflammatory response and neonatal outcome in pregnancies complicated by preterm prelabor rupture of membranes (pPROM). A retrospective study of 158 women with singleton pregnancies complicated by pPROM between 24(0/7) and 36(6/7) weeks was conducted. Amniotic fluid was obtained from all women by transabdominal amniocentesis, and umbilical cord blood was obtained by venipuncture from umbilical cords immediately after the delivery of the neonates. The Ureaplasma species and M. hominis DNA was quantitated using absolute quantification techniques. Ureaplasma species and M. hominis DNA was identified in 9% of the umbilical cord blood samples. No correlation between the amniotic fluid and umbilical cord blood microbial load was observed. The presence of Ureaplasma species and M. hominis DNA in the umbilical cord blood had no impact on short-term neonatal morbidity. A high microbial load of genital mycoplasma Ureaplasma species DNA in the umbilical cord in pregnancies complicated by pPROM is not associated with a high fetal inflammatory response and is therefore not associated with serious neonatal morbidity.

  11. Defining the residual risk of adverse perinatal outcome in growth restricted fetuses with normal umbilical artery blood flow.

    LENUS (Irish Health Repository)

    O'Dwyer, Vicky

    2014-07-25

    To determine the cause of adverse perinatal outcome in fetal growth restriction(FGR) where umbilical artery Doppler(UA) was normal, as identified from the Prospective Observational Trial to Optimize Pediatric Health(PORTO). We compared cases of adverse outcome where UA Doppler was normal and abnormal.

  12. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  13. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    Science.gov (United States)

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Heparin for prolonging peripheral intravenous catheter use in neonates: a randomized controlled trial.

    Science.gov (United States)

    Upadhyay, A; Verma, K K; Lal, P; Chawla, D; Sreenivas, V

    2015-04-01

    To determine the efficacy of heparinized saline administered as intermittent flush on functional duration of the peripheral intravenous catheter (PIVC) in neonates. Randomized, double-blind and placebo-controlled trial. Neonatal intensive care unit of a teaching hospital. Term and preterm neonates born at >32 weeks of gestation who required PIVC only for intermittent administration of antibiotics. Eligible neonates were randomized to receive 1 ml of either heparinized saline (10 U ml(-1)) (n=60) or normal saline (n=60) every 12 h before and after intravenous antibiotics. Functional duration of first peripheral intravenous catheter. A total of 120 neonates were randomized to two groups of 60 neonates each. The mean (s.d.) of age of babies in case and control group was 5.7 (2.5) days and 4.6 (3.1) days, respectively. The average weight of babies in both the groups was 2.1 kg. Mean functional duration of first catheter was more in heparinized saline group, mean (s.d.) of 71.68 h  (27.3) as compared with 57.7 h (23.6) in normal saline group (P<0.005). The mean (95% confidence interval) difference in functional duration in the two groups was 13.9 h (4.7-23.15). Mean duration of patency for any catheter was also significantly more in heparinized saline group than control group. Heparinized saline flush increases the functional duration of peripheral intravenous catheter.

  15. Hexachlorocyclohexanes (HCHs) in placenta and umbilical cord blood and dietary intake for women in Beijing, China

    International Nuclear Information System (INIS)

    Yu, Yanxin; Wang, Bin; Wang, Xilong; Wang, Rong; Wang, Wentao; Shen, Guofeng; Shen, Huizhong; Li, Wei; Wong, Minghong; Liu, Wenxin; Tao, Shu

    2013-01-01

    Placenta and umbilical cord blood are important media for investigating maternal–fetal exposure to environmental pollutants. Historically hexachlorocyclohexanes (HCHs) were once widely-used in China. In this study, residues of HCHs were measured in placenta and umbilical cord blood samples for 40 women from Beijing. The measured median values of HCHs were 62.0 and 68.8 ng/g fat in placenta and umbilical cord blood, respectively. Concentrations of HCHs in placenta and umbilical cord blood of urban cohort were higher than those of rural group due to enhanced consumption of fish, meat, and milk. Residues of HCHs in placenta were significantly correlated with total food consumption, dietary intake, and maternal age, and could be predicted using the parameters dependent upon ingestion of meat and milk. The transplacental exposure of fetuses to HCHs was revealed by a close association between the residual levels in the paired placenta and the paired umbilical cord blood samples. -- Highlights: •Medians of HCH in placenta and umbilical cord blood of 40 puerperal women from Beijing were 62.0 and 68.8 ng/g⋅fat. •HCHs in placenta and umbilical cord blood of urban cohort were higher than those of rural one. •HCH residues in placenta were significantly correlated with total food consumption, daily dietary intake, and maternal age. •The transplacental exposure of fetus to HCHs was revealed. -- HCHs in placenta of women in Beijing were significantly correlated with total food consumption, dietary intake, and maternal age

  16. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... prevented. ... blood from both the catheter and a peripheral site, may ... Given the important role of cutaneous microflora in the ... valvular heart disease (especially prosthetic valves) and ... be explained by high arterial flow around the catheter, ... vena cava or right atrium via the cephalic and basilar veins of ...

  17. Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Tomkowiak, Michael T.; Raval, Amish N.; Van Lysel, Michael S.

    2010-01-01

    Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm 2 mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0±0.8 mm (mean ±one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error (±0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The

  18. Trans-umbilical Laparoscopic Appendectomy for Acute Appendicitis ...

    African Journals Online (AJOL)

    Trans-umbilical Laparoscopic Appendectomy for Acute Appendicitis without Raising Skin-flaps: An Easy-to-use Modification Applied to the Series of 164 Patients from a Rural Institute of Central India. Priyadarshan Anand Jategaonkar, Sudeep Pradeep Yadav1. INTRODUCTION. Laparoscopic appendectomy (LA) is widely ...

  19. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  20. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  1. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  2. Innovating urinary catheter design: An introduction to the engineering challenge.

    Science.gov (United States)

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  3. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  4. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis

    International Nuclear Information System (INIS)

    Raheem, A.; Rana, A. I.; Ramzan, M.; Shah, R. A.; Mehmood, S. N.; Naseem, S.

    2014-01-01

    Objective: To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. Methods: The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Results: Of the total 122 catheters placed in 100 patients, 49(40.16%) were lost to follow-up. Of the remaining 73(59.83%) catheters, 38(52%) had achieved their desired function, while 35(48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13(37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129+-117 days. Conclusion: Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated. (author)

  5. Umbilical cord blood lactate: a valuable tool in the assessment of fetal metabolic acidosis

    DEFF Research Database (Denmark)

    Gjerris, A.C.; Staer-Jensen, J.; Jorgensen, J.S.

    2008-01-01

    asphyxia using ROC-curves, where an ABE value less than -12 was used as "gold standard" for significant intrapartum asphyxia. STUDY DESIGN: This is a descriptive study of umbilical cord arterial blood samples from 2554 singleton deliveries. The deliveries took place at the Department of Obstetrics......OBJECTIVE: The aim of the present study was (1) to evaluate the relationship between umbilical cord arterial blood lactate and pH, standard base excess (SBE), and actual base excess (ABE) at delivery and (2) to suggest a cut-off level of umbilical cord arterial blood lactate in predicting fetal...

  6. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  7. Control of intravascular catheters using an array of active steering coils.

    Science.gov (United States)

    Gudino, N; Heilman, J A; Derakhshan, J J; Sunshine, J L; Duerk, J L; Griswold, M A

    2011-07-01

    To extend the concept of deflecting the tip of a catheter with the magnetic force created in an MRI system through the use of an array of independently controllable steering coils located in the catheter tip, and to present methods for visualization of the catheter and/or surrounding areas while the catheter is deflected. An array of steering coils made of 42-gauge wire was built over a 2.5 Fr (0.83 mm) fiber braided microcatheter. Two of the coils were 70 turn axial coils separated by 1 cm, and the third was a 15-turn square side coil that was 2 x 4 mm2. Each coil was driven independently by a pulse width modulation (PWM) current source controlled by a microprocessor that received commands from a MATLAB routine that dynamically set current amplitude and direction for each coil. The catheter was immersed in a water phantom containing 1% Gd-DTPA that was placed at the isocenter of a 1.5 T MRI scanner. Deflections of the catheter tip were measured from image-based data obtained with a real-time radio frequency (RF) spoiled gradient echo sequence (GRE). The small local magnetic fields generated by the steering coils were exploited to generate a hyperintense signal at the catheter tip by using a modified GRE sequence that did not include slice-select rewinding gradients. Imaging and excitation modes were implemented by synchronizing the excitation of the steering coil array with the scanner by ensuring that no current was driven through the coils during the data acquisition window; this allowed visualization of the surrounding tissue while not affecting the desired catheter position. Deflections as large as 2.5 cm were measured when exciting the steering coils sequentially with a 100 mA maximum current per coil. When exciting a single axial coil, the deflection was half this value with 30% higher current. A hyperintense catheter tip useful for catheter tracking was obtained by imaging with the modified GRE sequence. Clear visualization of the areas surrounding the

  8. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  9. Effect of hypertensive disorders during pregnancy on neonatal outcomes and umbilical artery flow

    Directory of Open Access Journals (Sweden)

    Dong-mei ZHENG

    2013-09-01

    Full Text Available Objective To observe the effect of hypertensive disorders during pregnancy (HDP on neonatal outcomes and umbilical artery flow. Methods A prospective cohort study method was employed, and 60 pregnant women met the HDP diagnostic criteria (HDP group, aged 31.2±6.0 years, gestation time 251.0±9.0d, hospitalized from Sep. 2011 to May. 2012, and delivered live-born infants and 63 pregnant women with normal blood pressure and without medical or surgical ailments (control group, aged 30.2±2.8 years, gestation time 251.9±7.7d, hospitalized in the the same period, and had live birth were involved in present study. The indexes of umbilical artery blood flow were measured, the adverse neonatal outcomes (neonatal asphyxia, low birth weight babies and premature labor were recorded, and the correlation was analyzed between the adverse neonatal outcomes and the indexes of umbilical artery blood flow. Results The incidence of adverse neonatal outcomes (neonatal asphyxia, low birth weight newborns and premature labor was higher in HDP group (58.3%, 45.0% and 53.3%, respectively than in control group (6.3%, 3.2% and 3.2%, respectively, P<0.05. The results of umbilical artery blood flow indexes, including pulsatility index (PI, resistance index (RI and systolic/diastolic ratio (S/D in HDP group (0.897±0.176, 0.588±0.701 and 2.655±0.346, respectively were significantly higher than in control group (0.741±0.123, 0.525±0.650 and 2.120±0.364, respectively, P<0.05. The indexes of umbilical artery blood flow (PI, RI and S/D in newborns with adverse outcomes were significantly higher than in those newborn without adverse outcomes. Multivariate logistic regression revealed a positive correlation between RI and adverse neonatal outcomes. Conclusions The indexes of umbilical artery blood flow appear to be abnormal in pregnant women with HDP, and adverse neonatal conditions (neonatal asphyxia, low birth weight newborns and premature labor are prone to

  10. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  11. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  12. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  13. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  14. Dimerized plasmin fragment D as a potential biomarker to predict successful catheter-directed thrombolysis therapy in acute deep vein thrombosis.

    Science.gov (United States)

    Luo, Chien-Ming; Wu, I-Hui; Chan, Chih-Yang; Chen, Yih-Sharng; Yang, Wei-Shiung; Wang, Shoei-Shen

    2015-10-01

    The value of dimerized plasmin fragment D in the clinical monitoring during the catheter-directed thrombolysis in patients with acute deep vein thrombosis is not known. Dimerized plasmin fragment D levels in 24 patients with acute deep vein thrombosis undergoing catheter-directed thrombolysis were prospectively evaluated. The plasma dimerized plasmin fragment D level was measured serially before and at every 12 h during catheter-directed thrombolysis for 24 h. Technical success was defined as restoration of patency and flow with less than 50% residual thrombus by surveillance rotational venography. Technical success was achieved in 79.2% (19 of 24) of the treated limbs after catheter-directed thrombolysis. In univariate analysis, there was significant elevation of the dimerized plasmin fragment D at 12th h after starting the catheter-directed thrombolysis (P fragment D to predict successful catheter-directed thrombolysis was determined as 18.4 µg/ml at the 12th h after starting the catheter-directed thrombolysis with sensitivity 0.8 and specificity 0.8 (P = 0.03). It was further validated in multivariate logistic regression analysis (odds ratio: 14.38; 95% CI: 1.22-169.20; P = 0.03). Catheter-directed thrombolysis is safe and effective for restoration of blood flow in patients with acute deep vein thrombosis. Dimerized plasmin fragment D value greater than 18.4 µg/ml at the 12th h after starting catheter-directed thrombolysis had a high predictive rate of greater than 50% lysis at the end of catheter-directed thrombolysis. © The Author(s) 2014.

  15. Organochlorine pesticide levels in umbilical cord blood of newborn in Veracruz, Mexico.

    Science.gov (United States)

    Herrero-Mercado, Margarita; Waliszewski, S M; Caba, M; Martínez-Valenzuela, C; Hernández-Chalate, F

    2010-10-01

    Organochlorine pesticides accumulate in lipid rich compartments of organisms. During pregnancy, the compounds pass through the placental barrier appear in cord blood. The aim of this study was to monitor the levels of organochlorine pesticides in 70 umbilical cord blood samples taken during deliveries in Veracruz in 2009. For organochlorine pesticides, only the presence β-HCH (4%, 3.9 μg/L median concentration on wet weight), pp'DDE (100%, 0.7 μg/L) and pp'DDT (4%, 1.4 μg/L) were detected. The total pool of samples divided according to sex of new born babies, showed no statistical differences among median concentrations. The number of deliveries considered as a determinant contamination factor affirmed there were no statistical differences among median concentrations; however pp'DDE levels increased from the one to two childbirth groups. Age of pregnant women as a discriminate factor manifests in a significant increase in contamination levels among first, second and third tertile. In general, umbilical cord blood samples in Veracruz contained organochlorine pesticides, especially pp'DDE, confirming the presence of these compounds in the environment and their transfer from the mother to the developing fetus.

  16. [Umbilical blood-gas status at cesarean section for breech presentation: a comparison with vertex presentation].

    Science.gov (United States)

    Haruta, M; Saeki, N; Naka, Y; Funato, T; Ohtsuki, Y

    1989-10-01

    Umbilical blood-gas status at elective cesarean section with oxygen inhalation for breech presentation (25 cases) was compared with that for vertex presentation (25 cases), so as to confirm the security of full-term breech fetuses delivered by cesarean section under spinal anesthesia. Umbilical arterial oxygen levels were significantly lower in the breech group (Mean PO2:18.9 mmHg; SO2:37.3%; Oxygen content:7.6 ml/dl). The number of hypoxemic fetuses was significantly higher in the breech group (the breech: 7; the vertex; 0). The other umbilical blood-gas values revealed no significant differences between the breech and vertex groups, and were within normal limits in both groups. Oxygen extraction in the breech (Mean: 49.0%) was higher than that in the vertex (32.9%). Therefore decreased umbilical blood flow in the breech was suggested. The incidence of depression at 1 minute after delivery in the breech infants (24%) was significantly higher than that in the vertex infants (0%). It became obvious in the breech that as the interval between the uterine incision and delivery increased, umbilical arterial blood tended to acidosis and the 1 minute Apgar score decreased. Cesarean section for breech presentation requires sufficient and optimal incisions of the abdominal wall and uterus as well as a skillful manual delivery technique, because the fetus or neonate should be protected against asphyxia resulting from umbilical compression and prolonged delivery interval.

  17. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  18. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  19. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    International Nuclear Information System (INIS)

    Kulcsar, Zsolt; Yilmaz, Hasan; Bonvin, Christophe; Lovblad, Karl O.; Ruefenacht, Daniel A.

    2010-01-01

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

  20. Mortality Following Catheter Drainage Versus Thoracentesis in Cirrhotic Patients with Pleural Effusion.

    Science.gov (United States)

    Hung, Tsung-Hsing; Tseng, Chih-Wei; Tsai, Chen-Chi; Hsieh, Yu-Hsi; Tseng, Kuo-Chih; Tsai, Chih-Chun

    2017-04-01

    Pleural effusion is an abnormal collection of body fluids that may cause related morbidity or mortality in cirrhotic patients. There are insufficient data to determine the optimal method of drainage, for symptomatic relief in cirrhotic patients with pleural effusion. In this study, we compare the mortality outcomes of catheter drainage versus thoracentesis in cirrhotic patients. The National Health Insurance Database, derived from the Taiwan National Health Insurance Program, was used to identify cirrhotic patients with pleural effusion requiring drainage between January 1, 2007, and December 31, 2010. In all, 2556 cirrhotic patients with pleural effusion were selected for the study and divided into the two groups (n = 1278/group) after propensity score matching. The mean age was 61.0 ± 14.3 years, and 68.9% (1761/2556) were men. The overall 30-day mortality was 21.0% (538/2556) and was higher in patients treated with catheter drainage than those treated with thoracentesis (23.5 vs. 18.6%, respectively, P pleural effusion requiring drainage, catheter drainage is associated with higher mortality compared to thoracentesis.

  1. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  2. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    Science.gov (United States)

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular herophili, and the anterior formation of the SSS. The

  3. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  4. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  5. The use of peridural catheter in the treatment of chronic malignant pain in the abdomen: Case report (peridural catheter in the treatment chronic pain

    Directory of Open Access Journals (Sweden)

    Palibrk Ivan

    2017-01-01

    Full Text Available Introduction: Chronic pain in the abdomen occurs as a consequence of malignancy in these parts of the body, surgical, of radiological and chemotherapy treatments. It may also be as a result of relapse of the basic process. Non-invasive therapy of oral and transdermal analgesic was successful for some time, where necessary applies and epidural catheter. Case Report: The patient had a diagnosis of chronic postoperative pain malignant etiology. He is already used transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, but without success (VAS score 8-10. We increased doses of analgesics, but without success. In order of pain therapy, peridural catheter placed in the level L3 - L4. 5 ml of a solution of 8 ml of 0.25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline was administered every 6 hours through epidural catheter. The former chronic non-invasive treatment of pain did not stop. The first three to five days of pain relief was quite satisfactory in this way. Then the pain intensified but the peridural catheter had to be removed due to local infection. New peridural catheter was placed in the level L2 -L3. Then, 5 ml of the solution: of 8 ml 0,25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline is administered through peridural catheter. Peridural catheter was total used for 45 days. We had a need for more and more frequently administering analgesics through a catheter during use. The patient was using transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, all the time. The patient soon died due to progression of the underlying disease. Conclusion: After long-term administration of opioids, it is necessary to change the type and route of administration of the drug to achieve the success of the therapy. In this case it was the use of analgesics and local anesthetics through the peridural catheter.

  6. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  7. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  8. Detection of electrophysiology catheters in noisy fluoroscopy images

    NARCIS (Netherlands)

    Franken, E.M.; Rongen, P.M.J.; Almsick, van M.A.; Haar Romenij, ter B.M.

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust

  9. Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System.

    Science.gov (United States)

    Lillaney, Prasheel V; Yang, Jeffrey K; Losey, Aaron D; Martin, Alastair J; Cooke, Daniel L; Thorne, Bradford R H; Barry, David C; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W

    2016-10-01

    Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic

  10. Hemodialysis Access Usage Patterns in the Incident Dialysis Year and Associated Catheter-Related Complications

    Science.gov (United States)

    Xue, Hui; Ix, Joachim H.; Wang, Weiling; Brunelli, Steven M.; Lazarus, Michael; Hakim, Raymond; Lacson, Eduardo

    2012-01-01

    Background Hemodialysis(HD) access is considered a critical and actionable determinant of morbidity, with a growing literature suggesting that initial HD access type is an important marker of long term outcomes. Accordingly, we examined HD access during the incident dialysis period, focusing on infection risk and successful fistula creation over the first dialysis year. Study Design Longitudinal cohort Setting & Participants All United States adults admitted to Fresenius Medical Care North America facilities within 15 days of first maintenance dialysis session between January 1 and December 31, 2007. Predictor Vascular access type at HD initiation Outcomes Vascular access type at 90 days and at the end of the first year on HD, bloodstream infection within the first year by access type, and catheter complication rate. Results Amongst the 25,003 incident dialysis patients studied, 19,622(78.5%) initiated dialysis with a catheter, 4,151(16.6%) with a fistula, and 1,230(4.9%) with a graft. At 90 days, 14,105(69.7%) had a catheter, 4432(21.9%) patients had a fistula, and 1705(8.4%) had a graft. Functioning fistulas and grafts at dialysis initiation had first year failure rates of 10% and 15%, respectively. Grafts were seldom replaced by fistulas (3%), while 7,064 (47.6%) of all patients who initiated with a catheter alone still had only a catheter at 1 year. Overall, 3,327 (13.3%) patients had at least one positive blood culture during follow-up, with the risk being similar between fistula and graft groups, but approximately 3-fold higher in patients with a catheter (p<0.001 for either comparison). Nearly one in three catheters (32.5%) will require TPA use by median time of 41 days, with 59% requiring more than one TPA administration. Limitations Potential underestimation of bacteremia because follow-up blood culture results did not include samples sent to local laboratories. Conclusions Among a large and representative population of incident US dialysis patients

  11. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  13. Umbilical vein oxytocin in the management of third stage of labour.

    Directory of Open Access Journals (Sweden)

    Athavale R

    1991-10-01

    Full Text Available The aim of the study was to evaluate the efficacy of intra-umbilical oxytocin in minimizing the blood loss during 3rd and 4th stage of labour. Seventy-five pregnant multigravidas without any obstetric or medical complications were studied. It was found that the expulsion of the placenta was rapid as compared to the group treated with normal saline but not with methylergometrine. The drop in hemoglobin and hematocrit was comparable in patients receiving intra-umbilical oxytocin and those with active management of 3rd stage with methylergometrine.

  14. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  15. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  16. Ultrasound Assessment of Umbilical Cord Morphology in the First Trimester: A Feasibility Study

    DEFF Research Database (Denmark)

    Narayan, Rajit; Saaid, Rahmah; Pedersen, Lars Henning

    2015-01-01

    Objective: The aim of this study was to determine whether morphology and measurement of the umbilical cord could be accurately assessed at the time of the 11- to 13+6-week scan. Methods: We conducted a prospective study of 100 consecutive women with singleton pregnancies at 11-13+6 weeks' gestation...... be consistently studied in the first trimester. A subjective method of evaluation of the morphology may be a more reproducible technique until measurement strategies are refined and operator experience developed....

  17. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  18. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  19. Diagnostic accuracy of semi-quantitative and quantitative culture techniques for the diagnosis of catheter-related infections in newborns and molecular typing of isolated microorganisms.

    Science.gov (United States)

    Riboli, Danilo Flávio Moraes; Lyra, João César; Silva, Eliane Pessoa; Valadão, Luisa Leite; Bentlin, Maria Regina; Corrente, José Eduardo; Rugolo, Ligia Maria Suppo de Souza; da Cunha, Maria de Lourdes Ribeiro de Souza

    2014-05-22

    Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures. Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU. A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms, including S. epidermidis as the most prevalent species (65.5%), followed by S. haemolyticus (10.3%), yeasts (10.3%), K. pneumoniae (6.9%), S. aureus (3.4%), and E. coli (3.4%). The sensitivity of the semi-quantitative and quantitative techniques was 72.7% and 59.3%, respectively, and specificity was 95.7% and 94.4%. The diagnosis of CR-BSIs based on PFGE analysis of similarity between strains isolated from catheter tips and blood cultures showed 82.6% sensitivity and 100% specificity. The semi-quantitative culture method showed higher

  20. Effect of short-term exposure to two hydrophilic-coated and one gel pre-lubricated urinary catheters on sperm vitality, motility and kinematics in vitro.

    Science.gov (United States)

    Auger, J; Rihaoui, R; François, N; Eustache, F

    2007-06-01

    This study aimed to determine the in vitro effect of a short-term exposure to two hydrophilic-coated and one gel pre-lubricated urinary catheters on human sperm quality. Semen samples of various qualities were coincubated with each catheter for 5 min at 37 degrees C. The percentages of live and motile sperm with their kinematic characteristics were blindly assessed in control and treated samples at the end of the coincubation and 10 and 55 min later. The three catheters had no effect on sperm vitality. Similarly, the lubricated catheter and one hydrophilic-coated catheter negligibly modulated sperm motility. In contrast, the other hydrophilic-coated catheter tested had a significant negative effect on sperm movement. Further studies are warranted, the issue being especially relevant to the collection of spermatozoa in spinal cord diseased patients catheterizing themselves several times a day. In this population, compounds releasing from the catheter and accumulating in the urethra could be an additional factor contributing to the poor sperm quality.

  1. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  2. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  3. Using an indwelling catheter for the domiciliary management of malignant effusions

    Directory of Open Access Journals (Sweden)

    Ramkumar P

    2003-01-01

    Full Text Available Background: Many patients with malignant pleural effusions and ascites require repeated hospital visits for paracentesis. Materials and Methods: Patients and caregivers were taught to drain malignant effusions at home, using an indwelling catheter inserted into the pleural/ peritoneal cavity. The catheter, (ARROW 14 wire gauge with three additional side holes made to prevent blockage was inserted using the Seldenger technique for central venous cannulation and secured with a stitch. A three way stopcock was used to regulate fluid drainage. The caregiver was taught to do biweekly dressings with antiseptic ointment. Results: The catheter has been used in 200 patients over a period of five years. Two patients developed infections in the pleural cavity, which were managed with antibiotics. Two patients needed catheter change because of blockage. Other patients retained the catheter till last follow up or death. The procedure can be carried out as a day case. This article describes practical guidelines for inserting and maintaining the catheter.

  4. Do Foley Catheters Adequately Drain the Bladder? Evidence from CT Imaging Studies

    Directory of Open Access Journals (Sweden)

    Svetlana Avulova

    2015-06-01

    Full Text Available ABSTRACTIntroduction:The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder.Materials and Methods:Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomo-graphic (CT abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV was measured using 5mm axial CT sections as follows: The length (L and width (W of the bladder in the section with the greatest cross sectional area was combined with bladder height (H as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V of a sphere in a cube: V=(ϖ/6*(L*W*H.Results:RUVs of 167 (mean age 67 consecutively catheterized men (n=72 and women (n=95 identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL. Four (2.4% catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports.Conclusions:Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%, had adequately drained bladders with volumes of

  5. Do Foley catheters adequately drain the bladder? Evidence from CT imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Avulova, Svetlana; Li, Valery J.; Khusid, Johnathan A. [Department of Urology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Choi, Woo S. [Radiology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Weiss, Jeffrey P., E-mail: johnathan.khusid@downstate.edu [Department of Urology, Weill Cornell Medical College, New York, NY (United States)

    2015-05-15

    Introduction: The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder. Materials and Methods: Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomographic (CT) abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV) was measured using 5mm axial CT sections as follows: The length (L) and width (W) of the bladder in the section with the greatest cross sectional area was combined with bladder height (H) as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V) of a sphere in a cube:V=(π/6)⁎L⁎W⁎H). Results: RUVs of 167 (mean age 67) consecutively catheterized men (n=72) and women (n=95) identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL). Four (2.4%) catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports. Conclusions: Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%), had adequately drained bladders with volumes of <50 mL. (author)

  6. Genomic biomarkers of prenatal intrauterine inflammation in umbilical cord tissue predict later life neurological outcomes.

    Directory of Open Access Journals (Sweden)

    Sloane K Tilley

    Full Text Available Preterm birth is a major risk factor for neurodevelopmental delays and disorders. This study aimed to identify genomic biomarkers of intrauterine inflammation in umbilical cord tissue in preterm neonates that predict cognitive impairment at 10 years of age.Genome-wide messenger RNA (mRNA levels from umbilical cord tissue were obtained from 43 neonates born before 28 weeks of gestation. Genes that were differentially expressed across four indicators of intrauterine inflammation were identified and their functions examined. Exact logistic regression was used to test whether expression levels in umbilical cord tissue predicted neurocognitive function at 10 years of age.Placental indicators of inflammation were associated with changes in the mRNA expression of 445 genes in umbilical cord tissue. Transcripts with decreased expression showed significant enrichment for biological signaling processes related to neuronal development and growth. The altered expression of six genes was found to predict neurocognitive impairment when children were 10 years old These genes include two that encode for proteins involved in neuronal development.Prenatal intrauterine inflammation is associated with altered gene expression in umbilical cord tissue. A set of six of the differentially expressed genes predict cognitive impairment later in life, suggesting that the fetal environment is associated with significant adverse effects on neurodevelopment that persist into later childhood.

  7. The left atrial catheter: its uses and complications.

    Science.gov (United States)

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  8. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  9. Development of A MEMS Based Manometric Catheter for Diagnosis of Functional Swallowing Disorders

    International Nuclear Information System (INIS)

    Hsu, H Y; Hariz, A J; Omari, T; Teng, M F; Sii, D; Chan, S; Lau, L; Tan, S; Lin, G; Haskard, M; Mulcahy, D; Bakewell, M

    2006-01-01

    Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is used in a feasibility study of developing a manometric catheter for functional swallowing disorders diagnosis. The function of a manometric catheter is to measure the peak and intrabolus pressures along the esophageal segment during the swallowing action. Previous manometric catheters used the water perfusion technique to measure the pressure changes. This type of catheter is reusable, large in size and the pressure reading is recorded by an external transducer. Current manometric catheters use a solid state pressure sensor on the catheter itself to measure the pressure changes. This type of catheter reduces the discomfort to the patient but it is reusable and is very expensive. We carried out several studies and experiments on the MEMS-based pressure sensor die, and the results show the MEMS-based pressure sensors have a good stability and a good linearity output response, together with the advantage of low excitation biasing voltage and extremely small size. The MEMS-based sensor is the best device to use in the new generation of manometric catheters. The concept of the new MEMS-based manometric catheter consists of a pressure sensing sensor, supporting ring, the catheter tube and a data connector. Laboratory testing shows that the new calibrated catheter is capable of measuring pressure in the range from 0 to 100mmHg and maintaining stable condition on the zero baseline setting when no pressure is applied. In-vivo tests are carried out to compare the new MEMS based catheter with the current version of catheters used in the hospital

  10. Human umbilical cord mesenchymal stromal cells in regenerative medicine.

    Science.gov (United States)

    Detamore, Michael S

    2013-11-25

    Cells of the human umbilical cord offer tremendous potential for improving human health. Cells from the Wharton’s jelly (umbilical cord stroma) in particular, referred to as human umbilical cord mesenchymal stromal cells (HUCMSCs), hold several advantages that make them appealing for translational research. In the previous issue of Stem Cell Research & Therapy, Chon and colleagues made an important contribution to the HUCMSC literature not only by presenting HUCMSCs as an emerging cell source for intervertebral disc regeneration in general and the nucleus pulposus in particular, but also by demonstrating that an extracellular matrix-based strategy might be preferred over the use of growth factors. By culturing HUCMSCs under hypoxia in serum-free conditions in the presence of Matrigel with laminin-111, they were able to achieve intense collagen II staining by 21 days without the addition of exogenous growth factors. There is tremendous translational significance here in that such raw materials may alleviate the need for the use of growth factors in some instances, and this may have important ramifications in reducing product cost and streamlining regulatory approval. Chon and colleagues provide a promising example of the potential of HUCMSCs, demonstrating the ability to guide HUCMSC differentiation even in the absence of serum and growth factors and supporting the use of HUCMSCs as a viable alternative in intervertebral disc regeneration.

  11. Amnioinfusion for potential or suspected umbilical cord compression in labour.

    Science.gov (United States)

    Hofmeyr, G Justus; Lawrie, Theresa A

    2012-01-18

    Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. To assess the effects of amnioinfusion for potential or suspected umbilical cord compression on maternal and perinatal outcome . We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 October 2011). Randomised trials of amnioinfusion compared with no amnioinfusion in women with babies at risk of umbilical cord compression in labour. The original review had one author only (Justus Hofmeyr (GJH)). For this update, two authors (GJH and T Lawrie) assessed 13 additional trial reports for eligibility and quality. We extracted data and checked for accuracy. We have included 19 studies, with all but two studies having fewer than 200 participants. Transcervical amnioinfusion for potential or suspected umbilical cord compression was associated with the following reductions: caesarean section overall (13 trials, 1493 participants; average risk ratio (RR) 0.62, 95% confidence interval (CI) 0.46 to 0.83); fetal heart rate (FHR) decelerations (seven trials, 1006 participants; average RR 0.53, 95% CI 0.38 to 0.74); Apgar score less than seven at five minutes (12 trials, 1804 participants; average RR 0.47, 95% CI 0.30 to 0.72); meconium below the vocal cords (three trials, 674 participants, RR 0.53, 95% CI 0.31 to 0.92); postpartum endometritis (six trials, 767 participants; RR 0.45, 95% CI 0.25 to 0.81) and maternal hospital stay greater than three days (four trials, 1051 participants; average RR 0.45, 95% CI 0.25 to 0.78). Transabdominal amnioinfusion showed similar trends, though numbers studied were small.Mean cord umbilical artery pH was higher in the amnioinfusion group (seven trials, 855 participants; average mean difference 0.03, 95% CI 0.00 to 0.06) and there was a trend toward fewer neonates with a low cord arterial pH (less than 7.2 or as defined by trial authors) in the amnioinfusion group (eight trials, 972

  12. Urinary catheterization diary – A useful tool in tracking causes of non-deflating Foley catheter

    Directory of Open Access Journals (Sweden)

    C.O. Okorie

    2015-06-01

    Conclusions: Most urinary catheters marketed in developing countries are unidentifiable after unpacking. A catheterization diary is a useful tool for solving catheter-related problems, and its application in health-care facilities should be encouraged. Companies marketing Foley catheters should print the catheter name on both the catheter packaging and on the catheter itself.

  13. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially

  14. Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

    International Nuclear Information System (INIS)

    Keeling, A. N.; Leong, S.; Logan, P. M.; Lee, M. J.

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema

  15. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  16. Comparison of Diverting Colostomy and Bowel Management Catheter Applications in Fournier Gangrene Cases Requiring Fecal Diversion.

    Science.gov (United States)

    Eray, Ismail Cem; Alabaz, Omer; Akcam, Atilgan Tolga; Ulku, Abdullah; Parsak, Cem Kaan; Sakman, Gurhan; Seydaoglu, Gulsah

    2015-12-01

    In some patients of Fournier gangrene originated from perianal region, it is important to prevent fecal contamination in order to provide healing without wound infection. For this purposes, diverting colostomy or bowel management catheter methods were performed. In this study, it is aimed to carry out a comparison of prognosis and cost efficiency between diverting colostomy and bowel management catheter methods applied for preventing fecal contamination in Fournier's gangrene patients. Fourty-eight patients with diagnosis of Fournier's gangrene, serious perianal infections, and preserved sphincters and without rectum injury after debridement were included in the study. The cases were divided into two groups as patients who were subjected to colostomy for fecal diversion and who were subjected to bowel management catheter without colostomy. Then, the groups were compared in terms of age, predisposing factors, duration of hospital stay, mortality, additional surgery requirements, and cost. Fourty-eight patients were included the study. Sixteen patients were treated without colostomy. Decreased duration of total hospital stay, additional surgery requirements, and hospital expense in bowel management catheter group has determined. It is thought that preferring bowel management catheter method instead of colostomy in patients without rectum injury, who require diverting colostomy and have undamaged anal sphincters, can relieve patients, patients' relatives, healthcare organizations, and the national economy of a serious burden. In addition, although patients' satisfaction and workforce loss factors are not taken into consideration in this study, the bowel management catheter method is thought to have positive effects also on these parameters.

  17. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  18. Clinical study of the Erlanger silver catheter--data management and biometry.

    Science.gov (United States)

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  19. Predicting success of catheter drainage in infected necrotizing pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; Van Brunschot, Sandra; Bakker, Olaf J.; Ali, Usama Ahmed; Van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; Van Santvoort, Hjalmar C.

    2016-01-01

    Introduction: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. Methods: This was a

  20. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, R.A.; Bollen, T.L.; Brunschot, S. van; Bakker, O.J.; Ali, U. Ahmed; Goor, H. van; Boermeester, M.A.; Gooszen, H.G.; Besselink, M.G.; Santvoort, H.C. van

    2016-01-01

    INTRODUCTION: At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. METHODS: This was a

  1. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    Science.gov (United States)

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  2. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  3. Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lugez, Elodie; Sadjadi, Hossein; Joshi, Chandra P; Akl, Selim G; Fichtinger, Gabor

    2017-04-01

    Electromagnetic (EM) catheter tracking has recently been introduced in order to enable prompt and uncomplicated reconstruction of catheter paths in various clinical interventions. However, EM tracking is prone to measurement errors which can compromise the outcome of the procedure. Minimizing catheter tracking errors is therefore paramount to improve the path reconstruction accuracy. An extended Kalman filter (EKF) was employed to combine the nonlinear kinematic model of an EM sensor inside the catheter, with both its position and orientation measurements. The formulation of the kinematic model was based on the nonholonomic motion constraints of the EM sensor inside the catheter. Experimental verification was carried out in a clinical HDR suite. Ten catheters were inserted with mean curvatures varying from 0 to [Formula: see text] in a phantom. A miniaturized Ascension (Burlington, Vermont, USA) trakSTAR EM sensor (model 55) was threaded within each catheter at various speeds ranging from 7.4 to [Formula: see text]. The nonholonomic EKF was applied on the tracking data in order to statistically improve the EM tracking accuracy. A sample reconstruction error was defined at each point as the Euclidean distance between the estimated EM measurement and its corresponding ground truth. A path reconstruction accuracy was defined as the root mean square of the sample reconstruction errors, while the path reconstruction precision was defined as the standard deviation of these sample reconstruction errors. The impacts of sensor velocity and path curvature on the nonholonomic EKF method were determined. Finally, the nonholonomic EKF catheter path reconstructions were compared with the reconstructions provided by the manufacturer's filters under default settings, namely the AC wide notch and the DC adaptive filter. With a path reconstruction accuracy of 1.9 mm, the nonholonomic EKF surpassed the performance of the manufacturer's filters (2.4 mm) by 21% and the raw EM

  4. Catheter design optimization for practical intravascular photoacoustic imaging (IVPA) of vulnerable plaques

    Science.gov (United States)

    Iskander-Rizk, Sophinese; Wu, Min; Springeling, Geert; Mastik, Frits; Beurskens, Robert H. S. H.; van der Steen, Antonius F. W.; van Soest, Gijs

    2018-02-01

    Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium.

  5. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  6. Successful Use of Modified Suprapubic Catheter to Rescue Prostatorectal Fistula

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chiu

    2008-06-01

    Full Text Available Prostatorectal fistula is a complication following radiotherapy. It remains a clinical challenge to treat because most patients experience a poor quality of life. This case report discusses a modified suprapubic catheter for use in a patient with a prostatorectal fistula that developed after radiotherapy for localized prostate cancer. It is an inexpensive, easily available, and more patient-tolerable catheter that improves quality of life. Herein, we describe the development of this catheter.

  7. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  8. Longer Duration of Urinary Catheterization Increases Catheter-Associated Urinary Tract Infection in PICU.

    Science.gov (United States)

    Fukuoka, Kahoru; Furuichi, Mihoko; Ito, Kenta; Morikawa, Yoshihiko; Watanabe, Ichiro; Shimizu, Naoki; Horikoshi, Yuho

    2018-06-13

    Catheter-associated urinary tract infections account for 30% of healthcare-associated infections. To date, few studies have addressed pediatric catheter-associated urinary tract infection in PICUs. The aim of our study was to assess the risk of catheter-associated urinary tract infection in relation to the duration of catheterization in the PICU. Retrospective cohort study. PICU at a tertiary children's hospital. Our study was conducted between April 2012 and June 2015 at Tokyo Metropolitan Children's Medical Center in Japan. Children in the PICU with an urethral catheter were included. Catheter-associated urinary tract infection cases were defined according to the National Healthcare Safety Network criteria. The patients' demographic data and isolated organisms were reviewed. Duration of catheterization and the catheter-associated urinary tract infection occurrence rate were analyzed. None. Among 1,890 catheterizations, 23 catheter-associated urinary tract infection cases were identified. The overall occurrence rate was 2.35/1,000 catheter-days. Among the patients with catheter-associated urinary tract infection, 13 were boys. The median age was 11 months (interquartile range, 7-35 mo), and the median duration of catheterization was 7 days (interquartile range, 5-12 d). The isolated bacteria were Escherichia coli (26.5%), Enterococcus faecalis (17.6%), and Klebsiella pneumoniae (11.8%). Two species were isolated in each of 11 cases (47.8%). Each additional day of catheterization increased the risk of catheter-associated urinary tract infection (odds ratio, 1.06; 95% CI, 1.02-1.10, and odds ratio adjusted for contact precaution status and surgical procedures was 1.05; 95% CI, 1.01-1.09). Longer duration of catheterization increased the risk of catheter-associated urinary tract infection by 5% each day at the PICU. Prompt removal of the urethral catheter is strongly recommended whenever feasible.

  9. Reinnervation following catheter-based radio-frequency renal denervation.

    Science.gov (United States)

    Booth, Lindsea C; Nishi, Erika E; Yao, Song T; Ramchandra, Rohit; Lambert, Gavin W; Schlaich, Markus P; May, Clive N

    2015-04-20

    What is the topic of this review? Does catheter-based renal denervation effectively denervate the afferent and efferent renal nerves and does reinnervation occur? What advances does it highlight? Following catheter-based renal denervation, the afferent and efferent responses to electrical stimulation were abolished, renal sympathetic nerve activity was absent, and levels of renal noradrenaline and immunohistochemistry for tyrosine hydroxylase and calcitonin gene-related peptide were significantly reduced. By 11 months after renal denervation, both the functional responses and anatomical markers of afferent and efferent renal nerves had returned to normal, indicating reinnervation. Renal denervation reduces blood pressure in animals with experimental hypertension and, recently, catheter-based renal denervation was shown to cause a prolonged decrease in blood pressure in patients with resistant hypertension. The randomized, sham-controlled Symplicity HTN-3 trial failed to meet its primary efficacy end-point, but there is evidence that renal denervation was incomplete in many patients. Currently, there is little information regarding the effectiveness of catheter-based renal denervation and the extent of reinnervation. We assessed the effectiveness of renal nerve denervation with the Symplicity Flex catheter and the functional and anatomical reinnervation at 5.5 and 11 months postdenervation. In anaesthetized, non-denervated sheep, there was a high level of renal sympathetic nerve activity, and electrical stimulation of the renal nerve increased blood pressure and reduced heart rate (afferent response) and caused renal vasoconstriction and reduced renal blood flow (efferent response). Immediately after renal denervation, renal sympathetic nerve activity and the responses to electrical stimulation were absent, indicating effective denervation. By 11 months after denervation, renal sympathetic nerve activity was present and the responses to electrical stimulation

  10. Risk Factors for Neonatal Sepsis and Method for Reduction of Blood ...

    African Journals Online (AJOL)

    2015-03-24

    Mar 24, 2015 ... gestational age, low birth weight, mechanical ventilation, umbilical venous catheter ... congenital anomalies, amniotic fluid (appearance, odour, quantity) ... on positive clinical findings (food intolerance, vomiting, diarhoea or ...

  11. Surfactant Protein D Levels in Umbilical Cord Blood and Capillary Blood of Premature Infants

    DEFF Research Database (Denmark)

    Dahl, Marianne; Holmskov, Uffe; Husby, Steffen

    2006-01-01

    of SP-D in capillary blood day 1 was 1,466 ng/mL (range 410-5,051 ng/mL), with lowest values in infants born with ROM and delivered vaginally. High SP-D levels in umbilical cord blood and capillary blood on day 1 were found to be more likely in infants in need for respiratory support or surfactant...... treatment and susceptibility to infections. We conclude that SP-D concentrations in umbilical cord blood and capillary blood in premature infants are twice as high as in mature infants and depend on several perinatal conditions. High SP-D levels in umbilical cord blood and capillary blood on day 1 were...... found to be related to increased risk of RDS and infections....

  12. Percutaneous transvenous retrieval of CVP catheter emboli in S. V. C.-A case report-

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Lee, Deock Hee; Kim, Hong; Kim, Ok Bae

    1987-01-01

    The increasing use of the indwelling venous catheters and cardiovascular catheters has led to many iatrogenic complications. One of the most serious complications is catheter embolization, caused by inadvertent fracture of a fragment of catheter remaining within cardiovascular systems. In the catheter embolization, there are serious consequence such as thromboembolism, sepsis, cardiac arrhythmia and others. Fisher and Ferreyro (1978) reported a 71% incidence of serious morbidity or death following to intravascular foreign bodies in patients without removal. The authors experienced a case of retained central venous pressure monitoring catheter (CVP catheter) fragment extending from superior vena cava to hepatic segment of inferior vena cava. CVP catheter wa introduced into right subclavian venous route for hyperalimentation, because of poor general condition for operation of afferent loop syndrome following to resection of the gastric carcinoma with Billoth II operation (5 years age). On attempting removal of CVP catheter on recovery from afferent loop syndrome, a large portion of the CVP catheter was cut off in S.V.C. Percutaneous puncture of right femoral vein with Seldinger technique was done and 9F introducer sheath was indwelled. The helical basket of Dotter intravascular retriever set was advance through the sheath up to retained CVP catheter, and it was grasped. The retrieved CVP catheter fragment showed several tiny blood clots on surface. The patient was uneventfully recovered and was discharged asymptomatic on second day of the procedure.

  13. [Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].

    Science.gov (United States)

    Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A

    1994-01-01

    We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.

  14. Acquired umbilical hernias in four captive polar bears (Ursus maritimus).

    Science.gov (United States)

    Velguth, Karen E; Rochat, Mark C; Langan, Jennifer N; Backues, Kay

    2009-12-01

    Umbilical hernias are a common occurrence in domestic animals and humans but have not been well documented in polar bears. Surgical reduction and herniorrhaphies were performed to correct acquired hernias in the region of the umbilicus in four adult captive polar bears (Ursus maritimus) housed in North American zoos. Two of the four bears were clinically unaffected by their hernias prior to surgery. One bear showed signs of severe discomfort following acute enlargement of the hernia. In another bear, re-herniation led to acute abdominal pain due to gastric entrapment and strangulation. The hernias in three bears were surgically repaired by debridement of the hernia ring and direct apposition of the abdominal wall, while the large defect in the most severely affected bear was closed using polypropylene mesh to prevent excessive tension. The cases in this series demonstrate that while small hernias may remain clinically inconsequential for long periods of time, enlargement or recurrence of the defect can lead to incarceration and acute abdominal crisis. Umbilical herniation has not been reported in free-ranging polar bears, and it is suspected that factors such as body condition, limited exercise, or enclosure design potentially contribute to the development of umbilical hernias in captive polar bears.

  15. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    Science.gov (United States)

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Simultaneous isolation of vascular endothelial cells and mesenchymal stem cells from the human umbilical cord.

    Science.gov (United States)

    Kadam, Sachin S; Tiwari, Shubha; Bhonde, Ramesh R

    2009-01-01

    The umbilical cord represents the link between mother and fetus during pregnancy. This cord is usually discarded as a biological waste after the child's birth; however, its importance as a "store house" of stem cells has been explored recently. We developed a method of simultaneous isolation of endothelial cells (ECs) from the vein and mesenchymal stem cells from umbilical cord Wharton's jelly of the same cord. The isolation protocol has been simplified, modified, and improvised with respect to choice of enzyme and enzyme mixture, digestion time, cell yield, cell growth, and culture medium. Isolated human umbilical vascular ECs (hUVECs) were positive for von-Willibrand factor, a classical endothelial marker, and could form capillary-like structures when seeded on Matrigel, thus proving their functionality. The isolated human umbilical cord mesenchymal stem cells (hUCMSCs) were found positive for CD44, CD90, CD 73, and CD117 and were found negative for CD33, CD34, CD45, and CD105 surface markers; they were also positive for cytoskeleton markers of smooth muscle actin and vimentin. The hUCMSCs showed multilineage differentiation potential and differentiated into adipogenic, chondrogenic, osteogenic, and neuronal lineages under influence of lineage specific differentiation medium. Thus, isolating endothelial cells as well as mesenchymal cells from the same umbilical cord could lead to complete utilization of the available tissue for the tissue engineering and cell therapy.

  17. Catheter-free Period Over 2 Days Is Associated with Better Outcome in Catheter-related Bloodstream Infection due to Candida

    OpenAIRE

    Matsuo, Takahiro; Mori, Nobuyoshi; Hoshino, Eri; Sakurai, Aki; Furukawa, Keiichi

    2017-01-01

    Abstract Background Regardless of active antifungal drugs, mortality of candidemia remains high. Although it is well-known that central venous catheter (CVC) is one of the most important risk factors of candidemia and should be removed immediately, little is known about optimal timing of CVC replacement after removal. Here, we analyzed contributing risk factors associated with 30-day mortality for catheter-related bloodstream infection (CRBSI) due to candida and optimal timing of CVC replacem...

  18. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    Science.gov (United States)

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  19. Risk Factors for Catheter Associated Urinary Tract Infections in a Pediatric Institution.

    Science.gov (United States)

    Lee, Nora G; Marchalik, Daniel; Lipsky, Andrew; Rushton, H Gil; Pohl, Hans G; Song, Xiaoyan

    2016-04-01

    Catheter associated urinary tract infections are an essential measure for health care quality improvement that affects reimbursement through hospital acquired condition reduction programs in adult patients. With the mounting importance of preventing such infections we evaluated risk factors for acquiring catheter associated urinary tract infections in pediatric patients. All catheter associated urinary tract infections were identified at 1 pediatric institution from September 2010 to August 2014 from a prospective database maintained by the infection control office. To identify risk factors patients with a catheter associated urinary tract infection were individually matched to control patients with a urinary catheter but without infection by age, gender, date and the hospital location of the infection in 1:2 fashion. A total of 50 patients with catheter associated urinary tract infection were identified and matched to 100 control patients. Compared to controls the patients with infection were more likely to have a catheter in place for longer (2.9 days, OR 1.08, 95% CI 1.01, 1.15, p = 0.02). They were also more likely to be on contact precautions (OR 4.00, 95% CI 1.73, 9.26, p = 0.001), and have concurrent infections (OR 3.04, 95% CI 1.39, 6.28, p = 0.005) and a history of catheterization (OR 3.24, 95% CI 1.55, 6.77, p = 0.002). Using a conditional multivariate regression model the 3 most predictive variables were duration of catheter drainage, contact isolation status and history of catheterization. Longer duration of urinary catheter drainage, positive contact precautions status and a history of catheterization appear to be associated with a higher risk of catheter associated urinary tract infection in hospitalized pediatric patients. Physicians should attempt to decrease the duration of catheterization, especially in patients who meet these criteria, to minimize the risk of catheter associated urinary tract infection. Copyright © 2016 American Urological

  20. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  1. A simple method of using a Foley catheter to drain pleural effusion.

    Science.gov (United States)

    Ben-Nun, Alon; Best, Lael Anson

    2008-01-01

    Pleural effusion is a common problem, and various techniques of pleural fluid drainage have been described. We report our experience of using a Foley-type catheter to drain pleural effusion. After the injection of local anesthesia, the catheter is inserted, usually through the 7th intercostal space, with the patient sitting upright. The size of the catheter is selected according to the predicted fluid characteristics, and ranges from 18 to 24 F. Once the catheter is positioned in the pleural space, the balloon is inflated with diluted soluble contrast material and connected to a urine collection bag. During the last 10 years, we have used 3500 catheters for this purpose. The catheter site can be used as a port for various procedures, including needle biopsy of the parietal pleura, talc-slurry pleurodesis, and intra-pleural fibrinolysis. This method of pleural drainage is simple, reliable, and inexpensive.

  2. Predicting Success of Catheter Drainage in Infected Necrotizing Pancreatitis

    NARCIS (Netherlands)

    Hollemans, Robbert A.; Bollen, Thomas L.; van Brunschot, Sandra; Bakker, Olaf J.; Ahmed Ali, Usama; van Goor, Harry; Boermeester, Marja A.; Gooszen, Hein G.; Besselink, Marc G.; van Santvoort, Hjalmar C.

    2016-01-01

    At least 30% of patients with infected necrotizing pancreatitis are successfully treated with catheter drainage alone. It is currently not possible to predict which patients also need necrosectomy. We evaluated predictive factors for successful catheter drainage. This was a post hoc analysis of 130

  3. Abnormal umbilical cord Dopplers may predict impending demise in fetuses with sacrococcygeal teratoma. A report of 2 cases.

    Science.gov (United States)

    Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W

    2003-01-01

    To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT were reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2003 S. Karger AG, Basel

  4. Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.

    Science.gov (United States)

    Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin

    2012-01-01

    Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.

  5. [Multicenter clinical study on umbilical cord arterial blood gas parameters for diagnosis of neonatal asphyxia].

    Science.gov (United States)

    2010-09-01

    To obtain the normal range of statistics of umbilical artery blood gas parameters of the newborns for diagnosis of neonatal asphyxia. From March 2008 through September 2009, 17 978 singleton term appropriate for gestational age (AGA) or larger than gestational age (LGA) newborns in six hospitals of five provinces/autonomous regions were consecutively enrolled in this prospective study. The normal ranges of umbilical artery blood gas parameters were obtained from 17 645 newborns with 1 min Apgar score ≥ 8. The correlations between umbilical artery blood pH, BE and prenatal high-risk factors, Apgar scores, and organ damage were analyzed. The diagnostic criteria for asphyxia included the following: (1) Having high-risk factors that might cause asphyxia; (2) 1 min Apgar score ≤ 7 (the respiratory depression must be present); (3) At least one organ showed evidence of hypoxic damage; (4) Other causes of low Apgar score were excluded. The study focused on the distributive characteristics of umbilical artery blood pH (clinically corrected by Eisenberg formula) and BE values of the asphyxiated and non-asphyxiated cases in low Apgar score group, as well as the sensitivity and specificity of different selected pH and BE threshold spots within their distributing ranges. Among the 17 978 singleton term AGA or LGA newborns, the statistically normal range of umbilical artery blood pH, BE for the 17 645 cases with 1 min Apgar scores ≥ 8 were 7.20 ± 0.20 (x(-) ± 1.96 s) and -7.64 ± 10.02 (x(-) ± 1.96 s), respectively. The pH well correlated positively with BE (r = 0.734, P blood pH and BE values correlated positively with the Apgar scores. The umbilical artery blood pH and BE values correlated negatively with organ damage (r = 1, the P values = 0.000 for both). Among the 333 low Apgar score cases, the umbilical artery blood pH corrected values and BE values of the asphyxiated group (163 cases) were 7.011 ± 0.09 (x(-) ± s) and -14.98 ± 2.99 (x(-) ± s), being lower than

  6. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, London SE1 7EH (United Kingdom); Gogin, Nicolas; Cathier, Pascal [Medisys Research Group, Philips Healthcare, Paris 92156 (France); Gijsbers, Geert [Interventional X-ray, Philips Healthcare, Best 5680 DA (Netherlands); Cooklin, Michael; O' Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo [Department of Cardiology, Guys and St. Thomas' Hospitals NHS Foundation Trust, London SE1 7EH (United Kingdom)

    2013-07-15

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99

  7. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    Science.gov (United States)

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  8. Comparison between mechanical properties of human saphenous vein and umbilical vein

    Directory of Open Access Journals (Sweden)

    Hamedani Borhan

    2012-08-01

    Full Text Available Abstract Background As a main cause of mortality in developed countries, Coronary Artery Disease (CAD is known as silent killer with a considerable cost to be dedicated for its treatment. Coronary Artery Bypass Graft (CABG is a common remedy for CAD for which different blood vessels are used as a detour. There is a lack of knowledge about mechanical properties of human blood vessels used for CABG, and while these properties have a great impact on long-term patency of a CABG. Thus, studying these properties, especially those of human umbilical veins which have not been considered yet, looks utterly necessary. Methods Umbilical vein, as well as human Saphenous vein, are respectively obtained after cesarean and CABG. First, histological tests were performed to investigate different fiber contents of the samples. Having prepared samples carefully, force-displacement results of samples were rendered to real stress–strain measurements and then a fourth-order polynomial was used to prove the non-linear behavior of these two vessels. Results Results were analyzed in two directions, i.e. circumferentially and longitudinally, which then were compared with each other. The comparison between stiffness and elasticity of these veins showed that Saphenous vein’s stiffness is much higher than that of umbilical vein and also, it is less stretchable. Furthermore, for both vessels, longitudinal stiffness was higher than that of circumferential and in stark contrast, stretch ratio in circumferential direction came much higher than longitudinal orientation. Conclusion Blood pressure is very high in the region of aorta, so there should be a stiff blood vessel in this area and previous investigations showed that stiffer vessels would have a better influence on the flow of bypass. To this end, the current study has made an attempt to compare these two blood vessels’ stiffness, finding that Saphenous vein is stiffer than umbilical vein which is somehow as stiff as

  9. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    Urinary bladder catheter encrustations are known complications of long-term urinary catheterisation, which is commonly seen in clinical practice. These encrustations can impede deflation of the balloon and therefore cause problems in the removal of the catheter. The options in managing an encrusted and incarcerated ...

  10. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    2010-11-25

    Nov 25, 2010 ... cases of extraluminal encrusted urethral catheters. Extracorporeal shock wave lithotripsy (ESWL) has been utilised in the treatment of the bladder stones. Borrowing this principle, Kunzman et al. (12) has even used ESWL to fragment the stone-like encrustation over the retained Foley catheter balloon.

  11. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

    Directory of Open Access Journals (Sweden)

    Rolf Bambauer

    2012-01-01

    Full Text Available Background. Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels. Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications. Methods. This retrospective study (1992–2007 evaluated silver-coated (54 patients and noncoated (105 patients implanted large-bore catheters used for extracorporeal detoxification. The catheters were inserted into the internal jugular or subclavian veins. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using scanning electron microscope. Results. The silver coated catheters showed a tendency towards longer in situ time. The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant. Conclusion. The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study. There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort. Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

  12. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  13. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  14. Bi-layer sandwich film for antibacterial catheters.

    Science.gov (United States)

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  15. Bi-layer sandwich film for antibacterial catheters

    Directory of Open Access Journals (Sweden)

    Gerhard Franz

    2017-09-01

    Full Text Available Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters.Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene. This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition.Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier.

  16. A case report of umbilical ring constriction with application of amnioinfusion.

    Science.gov (United States)

    Tokunaka, Mayumi; Hasegawa, Junichi; Nakamura, Masamitsu; Hamada, Shoko; Matsuoka, Ryu; Ichizuka, Kiyotake; Sekizawa, Akihiko; Okai, Takashi

    2013-07-01

    This is a case report of a pregnant 38-year-old primigravida woman. Due to severe fetal growth restriction and oligohydramnios, she was referred to our tertiary perinatal center at 24 weeks' gestation. To rule out chromosomal abnormalities and facilitate ultrasound evaluation of fetal morphology, we performed amniocentesis and subsequent amnioinfusion. Thereafter, a precise ultrasound examination revealed no obvious fetal morphological abnormalities except for a hyper-coiled cord and marginal placenta previa. During expectant management, the amount of amniotic fluid was maintained at 20-26 mm for a few days; however, the pregnancy resulted in intrauterine fetal death after 26 weeks + 5 days of gestation. The stillborn infant weighed 530 g (-3.3 SD) and had no obvious external abnormalities apart from umbilical ring constriction. Although a postmortem autopsy was not performed, it is suspected that the fetal growth restriction and the intrauterine fetal death were associated with the hyper-coiled cord and the umbilical ring constriction. It is thought that umbilical ring constriction might therefore be an irreversible fatal condition in cases with a hyper-coiled cord.

  17. Bedside ultrasound reliability in locating catheter and detecting complications

    Directory of Open Access Journals (Sweden)

    Payman Moharamzadeh

    2016-10-01

    Full Text Available Introduction: Central venous catheterization is one of the most common medical procedures and is associated with such complications as misplacement and pneumothorax. Chest X-ray is among good ways for evaluation of these complications. However, due to patient’s excessive exposure to radiation, time consumption and low diagnostic value in detecting pneumothorax in the supine patient, the present study intends to examine bedside ultrasound diagnostic value in locating tip of the catheter and pneumothorax. Materials and methods: In the present cross-sectional study, all referred patients requiring central venous catheterization were examined. Central venous catheterization was performed by a trained emergency medicine specialist, and the location of catheter and the presence of pneumothorax were examined and compared using two modalities of ultrasound and x-ray (as the reference standard. Sensitivity, specificity, and positive and negative predicting values were reported. Results: A total of 200 non-trauma patients were included in the study (58% men. Cohen’s Kappa consistency coefficients for catheterization and diagnosis of pneumothorax were found as 0.49 (95% CI: 0.43-0.55, 0.89 (P<0.001, (95% CI: 97.8-100, respectively. Also, ultrasound sensitivity and specificity in diagnosing pneumothorax were 75% (95% CI: 35.6-95.5, and 100% (95% CI: 97.6-100, respectively. Conclusion: The present study results showed low diagnostic value of ultrasound in determining catheter location and in detecting pneumothorax. With knowledge of previous studies, the search still on this field.   Keywords: Central venous catheterization; complications; bedside ultrasound; radiography;

  18. Vaginal extrusion of a ventriculo-peritoneal shunt catheter in an adult

    Directory of Open Access Journals (Sweden)

    Christopher M Bonfield

    2015-01-01

    Full Text Available Ventriculo-peritoneal shunts (VPS are commonly used in the treatment of various neurosurgical conditions, including hydrocephalus and pseudotumor cerebri. We report only the second case of vaginal extrusion of a VPS catheter in an adult, and the first case with a modern VPS silastic peritoneal catheter. A 45-year-old female with a history of VPS for pseudotumor cerebri, Behcet′s syndrome, and hysterectomy presented to our institution with the chief complaint of tubing protruding from her vagina after urination. On gynecologic examination, the patient was found to have approximately 15 cm of VPS catheter protruding from her vaginal apex. A computed tomography scan of the abdomen and shunt X-ray series demonstrated no breaks in the tubing, but also confirmed the finding of the VPS catheter extruding through the vaginal cuff into the vagina. The patient had the VPS removed and an external ventricular drain was placed for temporary cerebrospinal fluid diversion. Ventricular catheter cultures were positive for diphtheroids. After an appropriate course of antibiotics, a contralateral ventriculo-pleural shunt was placed one week later. Although vary rare, vaginal extrusion can occur in adults, even with modern VPS catheters.

  19. Double balloon esophageal catheter for diagnosis of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Kiyan, Guersu; Dagli, Tolga E.; Tugtepe, Halil; Kodalli, Nihat

    2003-01-01

    Congenital H-type and recurrent tracheo-esophageal fistulas (TEF) are always difficult to diagnose. For a more accurate diagnosis we designed a new double balloon catheter, which is a modification of esophageal dilatation balloon. The catheter has two balloons to occlude the esophagus proximal and distal to the fistula. The fistula can be identified by passing of the contrast material to the tracheal tree, which was injected into the esophageal segment between the inflated balloons. To prove the efficiency of this catheter, a TEF was created surgically in a New Zealand rabbit. On the postoperative fourteenth day the catheter was tried and the fistula could be visualized easily by injecting the contrast material. We think this technique may be of use in the diagnosis of TEF in children. (orig.)

  20. A genome-wide comparison of mesenchymal stem cells derived from human placenta and umbilical cord

    Directory of Open Access Journals (Sweden)

    Sen-Wen Teng

    2017-10-01

    Conclusion: We identified the consistence and specific DEGs of human placenta and umbilical cord based on the genome-wide comparison. Our results indicated that hMSCs derived from umbilical cord and placenta have different gene expression patterns, and most of specific genes are involved in the cell cycle, cell division, cell death, and cell developmental processes.

  1. Determinants of maternal and umbilical blood lead levels: a cross-sectional study, Mosul, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Jomard Raghad A

    2009-03-01

    Full Text Available Abstract Background The populations who are most sensitive to lead exposure from various sources are pregnant women and their newborns. Aiming to explore the presence of correlation between maternal and cord blood lead levels and to identify potential predictors that may influence both levels, the present study has been conducted. Methods A cross-sectional study was conducted covering 350 full terms maternal-newborns pairs from Mosul maternity hospitals. Data were obtained directly from women just before delivery by the use of a detailed questionnaire form. Maternal and umbilical blood lead levels were estimated using LEADCARE® Blood Lead Testing System and Kits. Results A positive significant correlation was found between maternal and cord blood lead values (r = 0.856, p = 0.001. By backward stepwise logistic regression analysis the followings emerged as significant potential predictors of high maternal blood lead: low parity, smoking and Hb level Conclusion Study results have provided baseline data needed to be transformed to decision makers to implement measures to eliminate lead from the environment and protect future generation from its deleterious effects.

  2. A Randomized Controlled Trial of Music Use During Epidural Catheter Placement on Laboring Parturient Anxiety, Pain, and Satisfaction.

    Science.gov (United States)

    Drzymalski, Dan M; Tsen, Lawrence C; Palanisamy, Arvind; Zhou, Jie; Huang, Chuan-Chin; Kodali, Bhavani S

    2017-02-01

    Although music is frequently used to promote a relaxing environment during labor and delivery, the effect of its use during the placement of neuraxial techniques is unknown. Our study sought to determine the effects of music use on laboring parturients during epidural catheter placement, with the hypothesis that music use would result in lower anxiety, lower pain, and greater patient satisfaction. We conducted a prospective, randomized, controlled trial of laboring parturients undergoing epidural catheter placement with or without music. The music group listened to the patient's preferred music on a Pandora® station broadcast through an external amplified speaker; the control group listened to no music. All women received a standardized epidural technique and local anesthetic dose. The primary outcomes were 3 measures of anxiety. Secondary outcomes included pain, patient satisfaction, hemodynamic parameters, obstetric parameters, neonatal outcomes, and anesthesia provider anxiety. Intention-to-treat analysis with Bonferroni correction was used for the primary outcomes. For secondary outcomes, a P value of music group, the duration of music use was 31.1 ± 7.7 minutes (mean ± SD). The music group experienced higher anxiety as measured by Numeric Rating Scale scores immediately after epidural catheter placement (2.9 ± 3.3 vs 1.4 ± 1.7, mean difference 1.5 [95% confidence interval {CI} 0.2-2.7], P = .02), and as measured by fewer parturients being "very much relaxed" 1 hour after epidural catheter placement (51% vs 78%, odds ratio {OR} 0.3 [95% CI 0.1-0.9], P = .02). No differences in mean pain scores immediately after placement or patient satisfaction with the overall epidural placement experience were observed; however, the desire for music use with future epidural catheter placements was higher in the music group (84% vs 45%, OR 6.4 [95% CI 2.5-16.5], P Music use during epidural catheter placement in laboring parturients is associated with higher postprocedure

  3. Prolonged use of indwelling urinary catheter following acute urinary ...

    African Journals Online (AJOL)

    J.O. Bello

    prolonged use of urinary catheters following acute urinary retention secondary to benign prostate enlarge- ment (BPE) and urethral ... indwelling urinary catheter for >3 months following acute urinary retention due to BPE or USD. The study .... the major health-care financing strategy in Nigeria and accounts for more than ...

  4. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  5. True Umbilical Cord Knot Leading to Fetal Demise

    African Journals Online (AJOL)

    weight was 140 kg, height 1.69 m, blood pressure 120 mmHg. The booking ... The fetal heart tones were monitored using Doppler sonicaid. They remained normal throughout .... true knot, seemingly because the umbilical cord vessels can be compressed ... Therefore, the Wharton's jelly surrounding the fetal vessels has the ...

  6. Hydrophilic-coated catheter appreciation study in a pediatric population

    Science.gov (United States)

    Boucher, Andréanne; Cloutier, Jonathan; Lebel, Sylvie; Hamel, Micheline; Lamontagne, Pascale; Bolduc, Stéphane

    2010-01-01

    Objective: The objective of the paper was to compare the satisfaction of hydrophilic-coated catheters (HC) (SpeediCath, Coloplast Canada, Mississauga, ON) versus uncoated catheters in a pediatric neurogenic bladder population, in order to identify a target group for HC. The main hypothesis was that our patients, with regard to their limitations, might have difficulties using the HC. Material and methods: A comparative prospective study was initiated in one pediatric rehabilitation centre. Out of the 39 patients who tried the HC during a routine clinic visit, 31 patients/parents accepted to participate in a 1-week trial and to answer a satisfaction questionnaire. Their medical records were reviewed for age, neurological disease, intellectual deficit, impaired dexterity and method of catheterization (Mitrofanoff/urethra). Results: Thirty of the 31 patients answered the satisfaction questionnaire. The median age for the 30 patients was 13.5 years (range 6–20 years). Of these patients, 19 were females (63%), 26 performed self-catheterization (87%), and 6 had Mitrofanoff (20%). Ten children (33%) would be ready to proceed with HC and all 10 children would receive catheterization by the urethra. Of these, 9 were females (90%), 8 used compact-HC (80%) and all were self-sufficient. Patients using compact-HC would continue with this catheter. In the patient comments, males catheterizing per-urethra and patients using a continent stoma requiring long catheters had problems with the excess of lubricant. Conclusion: Most children preferred their usual uncoated catheter and would not change for HC. Female patients catheterizing per-urethra with a compact-HC seem to benefit most from this catheter. PMID:21749816

  7. Surface enhanced Raman spectroscopic direct determination of low molecular weight biothiols in umbilical cord whole blood.

    Science.gov (United States)

    Kuligowski, Julia; El-Zahry, Marwa R; Sánchez-Illana, Ángel; Quintás, Guillermo; Vento, Máximo; Lendl, Bernhard

    2016-04-07

    Biothiols play an essential role in a number of biological processes in living organisms including detoxification and metabolism. Fetal to neonatal transition poses a pro-oxidant threat for newborn infants, especially those born prematurely. A reliable and rapid tool for the direct determination of thiols in small volume whole blood (WB) samples would be desirable for its application in clinical practice. This study shows the feasibility of Surface Enhanced Raman Spectroscopy (SERS) using a silver colloid prepared by reduction of silver nitrate using hydroxylamine, as the SERS substrate for the quantification of thiols in WB samples after a simple precipitation step for protein removal. Bands originating from biothiols (790, 714 and 642 cm(-1)) were enhanced by the employed SERS substrate and the specificity of the detected SERS signal was tested for molecules presenting -SH functional groups. A statistically significant correlation between the obtained SERS signals and the thiol concentration measured using a chromatographic reference method in umbilical cord WB samples could be demonstrated. Using WB GSH concentrations obtained from the chromatographic reference procedure, a Partial Least Squares (PLS) regression model covering GSH concentrations from 13 to 2200 μM was calculated obtaining a root mean square error of prediction (RMSEP) of 381 μM when applied to an external test set. The developed approach uses small blood sample volumes (50 μL), which is important for clinical applications, especially in the field of neonatology. This feasibility study shows that the present approach combines all the necessary characteristics for its potential application in clinical practice.

  8. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    Science.gov (United States)

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  9. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  10. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    Science.gov (United States)

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  11. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    Science.gov (United States)

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  12. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    International Nuclear Information System (INIS)

    Ma Yingliang; Housden, R. James; Razavi, Reza; Rhode, Kawal S.; Gogin, Nicolas; Cathier, Pascal; Gijsbers, Geert; Cooklin, Michael; O'Neill, Mark; Gill, Jaswinder; Rinaldi, C. Aldo

    2013-01-01

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 ± 0.29, 0.92 ± 0.61, and 0.63 ± 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 ± 0.28, 0.64 ± 0.37, and 0.53 ± 0.38 mm and success rates increased to 100%, 99.2%, and 96

  13. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.

    Science.gov (United States)

    Kesner, Samuel B; Howe, Robert D

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.

  14. Umbilical cord PUFA are determined by maternal and child fatty acid desaturase (FADS) genetic variants in the Avon Longitudinal Study of Parents and Children (ALSPAC)

    Science.gov (United States)

    Lattka, Eva; Koletzko, Berthold; Zeilinger, Sonja; Hibbeln, Joseph R.; Klopp, Norman; Ring, Susan M.; Steer, Colin D.

    2012-01-01

    Fetal supply with long-chain PUFA (LC-PUFA) during pregnancy is important for brain growth and visual and cognitive development and is provided by materno–fetal placental transfer. We recently showed that maternal fatty acid desaturase (FADS) genotypes modulate the amounts of LC-PUFA in maternal blood. Whether FADS genotypes influence the amounts of umbilical cord fatty acids has not been investigated until now. The aim of the present study was to investigate the influence of maternal and child FADS genotypes on the amounts of LC-PUFA in umbilical cord venous plasma as an indicator of fetal fatty acid supply during pregnancy. A total of eleven cord plasma n-6 and n-3 fatty acids were analysed for association with seventeen FADS gene cluster SNP in over 2000 mothers and children from the Avon Longitudinal Study of Parents and Children. In a multivariable analysis, the maternal genotype effect was adjusted for the child genotype and vice versa to estimate which of the two has the stronger influence on cord plasma fatty acids. Both maternal and child FADS genotypes and haplotypes influenced amounts of cord plasma LC-PUFA and fatty acid ratios. Specifically, most analysed maternal SNP were associated with cord plasma levels of the precursor n-6 PUFA, whereas the child genotypes were mainly associated with more highly desaturated n-6 LC-PUFA. This first study on FADS genotypes and cord fatty acids suggests that fetal LC-PUFA status is determined to some extent by fetal fatty acid conversion. Associations of particular haplotypes suggest specific effects of SNP rs498793 and rs968567 on fatty acid metabolism. PMID:22877655

  15. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  16. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  17. Catheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis

    Directory of Open Access Journals (Sweden)

    Noriko Hattori

    2012-01-01

    Full Text Available Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter insertion—namely, catheter displacement into the inferior epigastric vein.

  18. Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.

    Science.gov (United States)

    Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G

    2013-09-01

    To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary

  19. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  20. Catheter-assisted retrieval of adhesive Geunther Tulip filter: preliminary experience

    International Nuclear Information System (INIS)

    Xiao Liang; Tong Jiajie; Xie Shiyang; Shen Jing

    2011-01-01

    Objective: To retrospectively summarize the technical experience in performing catheter-assisted retrieval of adhesive Geunther Tulip filter. Methods: During the period from November 2007 to October 2009, 95 patients with pulmonary embolism and acute deep vein thrombosis of lower limbs were admitted to authors' hospital. As simple snare technique failed to catch the adhesive Geunther Tulip filter previously implanted in inferior vena cava (IVC) in 6 patients (four males and two females with a mean age of 43.7 years), catheter-assisted retrieval of adhesive Geunther Tulip filter had to be carried out. The specific procedure was as follows. After phlebography of IVC confirmed that the filter's retrieval hook had adhered to IVC wall, the adhesion was separated with the help of catheter as well as goose-neck capturing device, then, the Geunther Tulip filter was retrieved. After the procedure, both anticoagulation and antibiotic medication were employed for 3-5 days. All the patients were followed up for 4-12 months. Vascular ultrasonography and pulmonary 3D CTA were re-examined in 6 months after primary operation. Results: All 6 adhesive Geunther Tulip filters were successfully removed with a success rate of 100%. The manipulation used in the procedure included catheter-twisting technique (n=1), catheter-looping technique (n=1) and catheter-snare looping technique (n=4). The mean operation time was 40.5 minutes (in the range of 17-78 minutes). The average filter-dwelling time was 46.7 days (ranging from 14 to 80 days). No thrombus formation in deep veins of lower extremity or pulmonary embolism occurred during the follow-up period. Conclusion: The catheter-assisted retrieval technique carries high retrieval rate for adhesive Geunther Tulip filter in IVC, it can markedly improve the retrieval success rate of Tulip IVC filter. (authors)