WorldWideScience

Sample records for denture base material

  1. Leaching from denture base materials in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Lygre, H.; Solheim, E.; Gjerdet, N.R. [School of Medicine, Univ. of Bergen (Norway)

    1995-04-01

    Specimens made from denture base materials were leached in Ringer Solution and in ethanol. The specimens comprised a heat-cured product processed in two different ways and two cold-cured materials. The organic compounds leaching from the specimens to the solutions were separated, identified, and quantified by a combined gas-chromatography and gas-chromatography/mass-spectrometry technique. Additives and degradation products, possibly made by free radical reactions, were released from the denture base materials. In Ringer solution only phthalates could be quantified. In ethanol solvent, biphenyl, dibutyl phthalate, dicyclohexyl phthalate, phenyl benzoate, and phenyl salicylate were quantified. In addition, copper was found in the ethanol solvent from one of the denture base materials. The amount of leachable organic compounds varies among different materials. Processing temperature influences the initial amount of leachable compounds. 36 refs., 7 figs., 1 tab.

  2. Flexible Thermoplastic Denture Base Materials for Aesthetical Removable Partial Denture Framework

    OpenAIRE

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-01-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated...

  3. Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

    Science.gov (United States)

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-10-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated, but location of clasps may affect aesthetics. So, when patient is concerned about aesthetics, flexible partial dentures which is aesthetically superior to flipper and cast partial dentures, may be considered. But for the success of flexible removable partial denture, proper diagnosis, treatment planning and insertion technique of this prosthesis is very important, which have been thoroughly described in this article.

  4. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    Science.gov (United States)

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36

  5. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study.

    Science.gov (United States)

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S

    2015-08-01

    The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.

  6. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    Science.gov (United States)

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the

  7. [Experimental basis of a new material for the manufacture of bases dentures].

    Science.gov (United States)

    Shturminskiĭ, V G

    2013-10-01

    The author studied the problem of improving the quality of prosthetic removable prostheses through the development of new basic material based on polypropylene copolymer. To this end, we examined the physical and chemical structure and hygienic properties of the produced material. The studies found that the developed material of polypropylene optimal solution for the partial plate denture bases, without flaws acrylic prosthesis and improves the properties of the previously used polypropylene plastics.

  8. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    Science.gov (United States)

    Nasution, Hubban; Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu

    2018-01-01

    The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets. The modulus of elasticity and nanohardness of each denture base (n=10) were measured on 15×15×15×3mm 3 specimen by using an ultramicroindentation system. The pressure transmission area, modulus of elasticity, and nanohardness data were statistically analyzed with 1-way ANOVA, followed by Tamhane or Tukey HSD post hoc test (α=.05). The maximum pressure transmission data were statistically analyzed with Kruskal-Wallis H test, followed by Mann-Whitney U test (α=.05). Polymethyl methacrylate showed significantly larger pressure transmission area and higher maximum pressure transmission than the other groups (Pelasticity and nanohardness among the four types of denture bases (Pelasticity and nanohardness of each type of denture base were demonstrated. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Mechanical and thermal properties of hydroxyapatite filled poly(methyl methacrylate) heat processed denture base material

    International Nuclear Information System (INIS)

    Mohamed, S.H.; Arifin, A.; Mohd Ishak, Z.A.; Nizam, A.; Samsudin, A.R.

    2004-01-01

    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (γ-MPS). Specimens for, mechanical testing were prepared by adding composites powder (PMMA, BPO and RA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSQ. It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained RA filler compared to commercial denture base material. (Author)

  10. The effect of cleaning substances on the surface of denture base material.

    Science.gov (United States)

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (pbaking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  11. Long-term microwaving of denture base materials: effects on dimensional, color and translucency stability

    Directory of Open Access Journals (Sweden)

    Nick POLYCHRONAKIS

    2018-06-01

    Full Text Available Abstract While the combined effect of microwave irradiation with cleansing solutions on denture base materials has been investigated, the effects of only using microwave irradiation and, more importantly, in a long-term basis, was not studied yet. Objective The purpose of this study was to evaluate the effect of a long-term repeated microwaving on the dimensional, color and translucency stability of acrylic and polyamide denture base materials. Material and Methods Thirty two specimens (32 mm x 10 mm x 2.5 mm from polyamide (Valplast and PMMA (Vertex Rapid Simplified denture base materials were made. Eight specimens from each material were immersed in distilled water (control and 8 were subjected to microwave exposure at 450 W for 3 minutes for a period simulating 224 days of daily disinfection. Linear dimension, color change (ΔE* and translucency parameter (TP were measured at baseline and after certain intervals up to 224 cycles of immersion, using a digital calliper and a portable colorimeter. The results were analysed using two-way repeated measures ANOVA to estimate possible differences among predetermined cycles and material type. Regression analysis was also performed to estimate the trend of changes with time. Statistical evaluations performed at a significance level of 5%. Results Data analysis showed significant changes in length at baseline with an increasing number of cycles (p0.05. TP decreased similarly in both materials following microwave action but in a significantly higher level for Valplast (p<0.001. Conclusions The results indicated that long-term repeated microwaving affects linear dimensional, color and translucency changes of both materials. Differences between PMMA and polyamide material were noted only in dimension and translucency changes.

  12. Use of Candida-specific chicken egg yolk antibodies to inhibit the adhering of Candida to denture base materials: prevention of denture stomatitis.

    Science.gov (United States)

    Kamikawa, Yoshiaki; Fujisaki, Junichi; Nagayama, Tomohiro; Kawasaki, Kiyotsugu; Hirabayashi, Daisuke; Hamada, Tomofumi; Sakamoto, Ryoich; Mukai, Hiroshi; Sugihara, Kazumasa

    2016-09-01

    Polyclonal anti-Candida chicken egg yolk antibodies (anti-IgY) were used to investigate the prevention of adherence of Candida species to denture base material in vitro. Candida is a potential virulence factor that can cause systemic infection and even death in immunocompromised individuals. Because long-term antifungal treatment may lead to the emergence of drug-resistant strains, it is necessary to develop novel preventive measures and treatments for candidiasis. Three types of chicken egg yolk antibodies were used in this study: non-specific antibody (control IgY), Candida albicans-specific antibody (anti-C.a.IgY) and Candida glabrata-specific antibody (anti-C.g.IgY). A mixture of different dilutions of each antibody with a suspension of Candida species and denture base material was incubated for 3 h, and then the colony-forming units of Candida on the denture base material were counted. Compared with control IgY, anti-C.a.IgY and anti-C.g.IgY significantly inhibited the adherence of C. albicans, but anti-C.a.IgY tended to be more potent than anti-C.g.IgY. The adherence of C. glabrata was also inhibited significantly by anti-C.a.IgY and anti-C.g.IgY with almost equivalent potency, indicating that their actions against C. glabrata were comparable. This study revealed the inhibitory effects of anti-C.a.IgY and anti-C.g.IgY against the adherence of C. albicans and C. glabrata to denture base material. This finding indicates the possibility of a beneficial effect of IgYs for the prevention of denture stomatitis and candidiasis in clinical settings. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  13. Residual monomer content determination in some acrylic denture base materials and possibilities of its reduction

    Directory of Open Access Journals (Sweden)

    Kostić Milena

    2009-01-01

    Full Text Available Background/Aim. Polymethyl methacrylate is used for producing a denture basis. It is a material made by the polymerization process of methyl methacrylate. Despite of the polymerization type, there is a certain amount of free methyl methacrylate (residual monomer incorporated in the denture, which can cause irritation of the oral mucosa. The aim of this study was to determine the amount of residual monomer in four different denture base acrylic resins by liquid chromatography and the possibility of its reduction. Methods. After the polymerization, a postpolymerization treatment was performed in three different ways: in boiling water for thirty minutes, with 500 W microwaves for three minutes and in steam bath at 22º C for one to thirty days. Results. The obtained results showed that the amount of residual monomer is significantly higher in cold polymerizing acrylates (9.1-11%. The amount of residual monomer after hot polymerization was in the tolerance range (0.59- 0.86%. Conclusion. The obtained results denote a low content of residual monomer in the samples which have undergone postpolymerization treatment. A lower percent of residual monomer is established in samples undergone a hot polymerization.

  14. Recent Advances and Future Perspectives for Reinforcement of Poly(methyl methacrylate Denture Base Materials: A Literature Review

    Directory of Open Access Journals (Sweden)

    Sahar Abdulrazzaq Naji

    2018-03-01

    Full Text Available Poly(methyl methacrylate (PMMA is the most common material used to fabricate complete and partial dentures. Despite its desirable properties, it cannot fulfill all mechanical requirements of prosthesis. Flexural fatigue due to repeated masticatory and high-impact forces caused by dropping are the main causes of denture fractures. In the past, different reinforcing agents such as rubbers, macro fibers, and fillers have been employed to improve the mechanical properties of denture base resins. Development of Nano dentistry has introduced new approaches for reinforcement of dental materials. Interest in nanostructure materials is driven by their high surface area to volume ratio, which enhances interfacial interaction and specific new biological, physical, and chemical properties. Researchers to reinforce PMMA resins have used Nanoparticles (Nps which were comprised of silver, Titania (TiO2, zirconia (ZrO2, alumina, and ceramic. Although different reports describe the use of nanofiber and nanotubes in dental composites, few studies have evaluated the reinforcement potential of nanofiber and nanotubes in PMMA denture base resins. The current article aims to review the different attempts to enhance the mechanical properties of denture base materials. We also focus on recent advances and potential future developments for reinforcement of the PMMA acrylic resins.

  15. Synthesis and biological evaluation of PMMA/MMT nanocomposite as denture base material.

    Science.gov (United States)

    Zheng, Junping; Su, Qiang; Wang, Chen; Cheng, Gang; Zhu, Ran; Shi, Jin; Yao, Kangde

    2011-04-01

    Inorganic-polymer nanocomposites are of significant interest for emerging materials due to their improved properties and unique combination of properties. Poly (methylmethacrylate) (PMMA)/montmorillonite (MMT) nanocomposites were prepared by in situ suspension polymerization with dodecylamine used as MMT-modifier. X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to characterize the structures of the nanocomposites. Cytotoxicity test, hemolysis test, acute systemic toxicity test, oral mucous membrane irritation test, guinea-pig maximization test and mouse bone-marrow micronucleus test were used to evaluate the biocompatibility of PMMA/MMT nanocomposites. The results indicated that an exfoliated nanocomposite was achieved, and the resulting nanocomposites exhibited excellent biocompatibility as denture base material and had potential application in dental materials.

  16. Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength.

    Science.gov (United States)

    Ha, Seung-Ryong; Yang, Jae-Ho; Lee, Jai-Bong; Han, Jung-Suk; Kim, Sung-Hun

    2010-03-01

    The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (ø 4 mm × 6 mm) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheffe test and independent sample t test (α = 0.05). Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

  17. Thermogravimetric Characterization of the Microstructui Composition of Polyamide Injection Molded Denture Base Material vs Conventional Compression Molded Heat-cured Denture Base Material.

    Science.gov (United States)

    Al-Dharrab, Ayman; Shinawi, Lana

    2016-02-01

    Thermoplastic resin polymers are widely used in medicine due to their biostability and hypoallergenic properties, making them a possible alternative to poly-methylmethacrylate (PMMA). The current research examined the microstructure of a rapid injection molding system thermoplastic resin for construction of flexible denture compared with that of heat-cured PMMA. A total of 40 disk-shaped specimens (25 mm in diameter and 3 mm in thickness) were prepared and divided into two groups of 20 disks each (group I samples were of thermoplastic acrylic resin while group II was heat-cured PMMA resin). In group I, thermogravimetric analyzer showed that increasing the temperature up to 169°C resulted in about 1.3% of the material loss, and after that the material remains thermally stable up to 200°C. Group 11 showed 2.24% weight loss at 171°C, and further weight loss (12.025%) was observed on heating to 230°C. Fourier transform infrared (FTIR) spectrophotometer analysis in the range of 400-4000 cm(-1) detected the presence of an amine group (N-H) in group I samples and the presence of methylene group attached to inorganic Si as reinforcement filler (Si-CH3). Thermoplastic resin displayed excellent thermal stability and the absence of residual monomer within the polymerized material, suggesting its suitability for the fabrication dentures.

  18. High-impact strength acrylic denture base material processed by autoclave.

    Science.gov (United States)

    Abdulwahhab, Salwan Sami

    2013-10-01

    To investigate the effect of two different cycles of autoclave processing on the transverse strength, impact strength, surface hardness and the porosity of high-impact strength acrylic denture base material. High Impact Acryl was the heat-cured acrylic denture base material included in the study. A total of 120 specimens were prepared, the specimens were grouped into: control groups in which high-impact strength acrylic resins processed by conventional water-bath processing technique (74°C for 1.5 h then boil for 30 min) and experimental groups in which high-impact strength acrylic resins processed by autoclave at 121°C, 210 kPa .The experimental groups were divided into (fast) groups for 15 min, and (slow) groups for 30 min. To study the effect of the autoclave processing (Tuttnauer 2540EA), four tests were conducted transverse strength (Instron universal testing machine), impact strength (Charpy tester), surface hardness (shore D), and porosity test. The results were analyzed to ANOVA and LSD test. In ANOVA test, there were highly significant differences between the results of the processing techniques in transverse, impact, hardness, and porosity test. The LSD test showed a significant difference between control and fast groups in transverse and hardness tests and a non-significant difference in impact test and a highly significant difference in porosity test; while, there were a highly significant differences between control and slow groups in all examined tests; finally, there were a non-significant difference between fast and slow groups in transverse and porosity tests and a highly significant difference in impact and hardness tests. In the autoclave processing technique, the slow (long) curing cycle improved the tested physical and mechanical properties as compared with the fast (short) curing cycle. The autoclave processing technique improved the tested physical and mechanical properties of High Impact Acryl. Copyright © 2013 Japan Prosthodontic Society

  19. Shear bond strength of a denture base acrylic resin and gingiva-colored indirect composite material to zirconia ceramics.

    Science.gov (United States)

    Kubochi, Kei; Komine, Futoshi; Fushiki, Ryosuke; Yagawa, Shogo; Mori, Serina; Matsumura, Hideo

    2017-04-01

    To evaluate the shear bond strengths of two gingiva-colored materials (an indirect composite material and a denture base acrylic resin) to zirconia ceramics and determine the effects of surface treatment with various priming agents. A gingiva-colored indirect composite material (CER) or denture base acrylic resin (PAL) was bonded to zirconia disks with unpriming (UP) or one of seven priming agents (n=11 each), namely, Alloy Primer (ALP), Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB+Act), Metal Link (MEL), Meta Fast Bonding Liner (MFB), MR. bond (MRB), and V-Primer (VPR). Shear bond strength was determined before and after 5000 thermocycles. The data were analyzed with the Kruskal-Wallis test and Steel-Dwass test. The mean pre-/post-thermalcycling bond strengths were 1.0-14.1MPa/0.1-12.1MPa for the CER specimen and 0.9-30.2MPa/0.1-11.1MPa for the PAL specimen. For the CER specimen, the ALP, CPB, and CPB+Act groups had significantly higher bond strengths among the eight groups, at both 0 and 5000 thermocycles. For the PAL specimen, shear bond strength was significantly lower after thermalcycling in all groups tested. After 5000 thermocycles, bond strengths were significantly higher in the CPB and CPB+Act groups than in the other groups. For the PAL specimens, bond strengths were significantly lower after thermalcycling in all groups tested. The MDP functional monomer improved bonding of a gingiva-colored indirect composite material and denture base acrylic resin to zirconia ceramics. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Mechanical properties of denture base resins: An evaluation

    Directory of Open Access Journals (Sweden)

    Pooran Chand

    2011-01-01

    Conclusion: The heat cure denture base material D (Trevalon "HI" was the strongest and C (Trevalon was the weakest among all materials used in this study. The study showed that the deflection of various denture base resins (A to D increases proportionately with the increase in load.

  1. Double-Layer Surface Modification of Polyamide Denture Base Material by Functionalized Sol-Gel Based Silica for Adhesion Improvement.

    Science.gov (United States)

    Hafezeqoran, Ali; Koodaryan, Roodabeh

    2017-09-21

    Limited surface treatments have been proposed to improve the bond strength between autopolymerizing resin and polyamide denture base materials. Still, the bond strength of autopolymerizing resins to nylon polymer is not strong enough to repair the fractured denture effectively. This study aimed to introduce a novel method to improve the adhesion of autopolymerizing resin to polyamide polymer by a double layer deposition of sol-gel silica and N-2-(aminoethyl)-3-aminopropyltrimethoxysilane (AE-APTMS). The silica sol was synthesized by acid-catalyzed hydrolysis of tetraethylorthosilicate (TEOS) as silica precursors. Polyamide specimens were dipped in TEOS-derived sol (TS group, n = 28), and exposed to ultraviolet (UV) light under O 2 flow for 30 minutes. UV-treated specimens were immersed in AE-APTMS solution and left for 24 hours at room temperature. The other specimens were either immersed in AE-APTMS solution (AP group, n = 28) or left untreated (NT group, n = 28). Surface characterization was investigated by fourier transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). Two autopolymerizing resins (subgroups G and T, n = 14) were bonded to the specimens, thermocycled, and then tested for shear bond strength with a universal testing machine. Data were analyzed with one-way ANOVA followed by Tukey's HSD (α = 0.05). FTIR spectra of treated surfaces confirmed the chemical modification and appearance of functional groups on the polymer. One-way ANOVA revealed significant differences in shear bond strength among the study groups. Tukey's HSD showed that TS T and TS G groups had significantly higher shear bond strength than control groups (p = 0.001 and p < 0.001, respectively). Moreover, bond strength values of AP T were statistically significant compared to controls (p = 0.017). Amino functionalized TEOS-derived silica coating is a simple and cost-effective method for improving the bond strength between the autopolymerizing resin and polyamide

  2. The Effect of Food-Simulating Agents on the Bond Strength of Hard Chairside Reline Materials to Denture Base Resin.

    Science.gov (United States)

    Fatemi, Farzaneh Sadat; Vojdani, Mahroo; Khaledi, Amir Ali Reza

    2018-06-08

    To investigate the influence of food-simulating agents on the shear bond strength between direct hard liners and denture base acrylic resin. In addition, mode of failure was evaluated. One hundred fifty cylindrical columns of denture base resin were fabricated and bonded to three types of hard reline materials (Hard GC Reline, Tokuyama Rebase II Fast, TDV Cold Liner Rebase). Specimens of each reline material were divided into five groups (n = 10) to undergo 12-day immersion in distilled water, 0.02 N citric acid aqueous solution, heptane, and 40% ethanol/water solution at 37°C. The control group was not immersed in any solution. The shear bond strength test was performed, and the failure mode was determined. Statistics were analyzed with two-way ANOVA and chi-square test (α = 0.05). Significant interaction was found between the hard liners and food simulating agents (p < 0.001). The shear bond strength of Tokuyama in 40% ethanol and TDV in heptane decreased significantly (p = 0.001, p < 0.001 respectively); however, none of the solutions could significantly affect the shear bond strength of Hard GC Reline (p = 0.208). The mixed failure mode occurred more frequently in Hard GC Reline compared with the other liners (p < 0.001) and was predominant in specimens with higher bond strength values (p = 0.012). Food simulating agents did not adversely affect the shear bond strength of Hard GC Reline; however, ethanol and heptane decreased the bond strength of Tokuyama and TDV, respectively. These findings may provide support to dentists to recommend restricted consumption of some foods and beverages for patients who have to use dentures relined with certain hard liners. © 2018 by the American College of Prosthodontists.

  3. The effect of gypsum products and separating materials on the typography of denture base materials.

    Science.gov (United States)

    Firtell, D N; Walsh, J F; Elahi, J M

    1980-09-01

    The typography of polymethyl methacrylate processed against various gypsum products coated with various separating materials was studied under an SEM. Tinfoil and two commercial tin foil substitutes were used as separating material during processing, and the surfaces of the resulting acrylic resin forms were studied for topographical differences. Tinfoil and alpha 2 hemihydrates produced the smoothest surfaces. As a practical solution, a good quality tinfoil substitute and alpha 1 hemihydrate could be used when processing polymethyl methacrylate resin.

  4. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials.

    Science.gov (United States)

    Zafar, Muhammad Sohail; Ahmed, Naseer

    2014-01-01

    Polymers have a wide range of applications in dentistry. Poly methyl methacrylate (PMMA) is the most popular for making orthodontic retainers, dentures as well as synthetic teeth. Prior to clinical applications, the appliances are polished in the dental laboratory to achieve smooth, polished and comfortable surfaces. The objective of this study was to analyze the surface roughness profiles of PMMA dentures polished using two different approaches. In addition, the effects of ultrasonication and sandblasting were also evaluated on the fitting surface of PMMA dentures. This was an in vitro study using non-contact mode surface roughness profilometer and nano-indenter. Samples were polished using two different techniques (Standard and modified). Both cold cure and heat cure PMMA denture surfaces were evaluated for roughness, nanohardness and elastic modulus. The absolute hardness was recorded 297.72±19.04 MPa and 229.93±18.53 MPa for heat cured PMMA and cold cured PMMA. Manufactured acrylic teeth were harder (319.20±12.58 MPa) with an elastic modulus of (4.34±1.86 GPa). Modified polishing techniques (group 3) produced smoother surface. It was concluded that elastic moduli of acrylic tooth and heat cure PMMA is not very different. Surface treatments such as ultrasonication or sandblasting do not affect the roughness profiles of denture fitting surfaces.

  5. Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins

    Directory of Open Access Journals (Sweden)

    Nour M. Ajaj-ALKordy

    2014-01-01

    Conclusion: Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.

  6. Hydrophilic nano-silica coating agents with platinum and diamond nanoparticles for denture base materials.

    Science.gov (United States)

    Yoshizaki, Taro; Akiba, Norihisa; Inokoshi, Masanao; Shimada, Masayuki; Minakuchi, Shunsuke

    2017-05-31

    Preventing microorganisms from adhering to the denture surface is important for ensuring the systemic health of elderly denture wearers. Silica coating agents provide high hydrophilicity but lack durability. This study investigated solutions to improve the durability of the coating layer, determine an appropriate solid content concentration of SiO 2 in the silica coating agent, and evaluate the effect of adding platinum (Pt) and diamond nanoparticles (ND) to the agent. Five coating agents were prepared with different SiO 2 concentrations with/without Pt and ND additives. The contact angle was measured, and the brush-wear test was performed. Scanning electron microscopy was used to investigate the silica coating layer. The appropriate concentration of SiO 2 was found to be 0.5-0.75 wt%. The coating agents with additives showed significantly high hydrophilicity immediately after coating and after the brush-wear test. The coating agents with/without additives formed a durable coating layer even after the brush-wear test.

  7. Effect of zirconium oxide nanoparticles addition on the optical and tensile properties of polymethyl methacrylate denture base material.

    Science.gov (United States)

    Gad, Mohammed M; Abualsaud, Reem; Rahoma, Ahmed; Al-Thobity, Ahmad M; Al-Abidi, Khalid S; Akhtar, Sultan

    2018-01-01

    Polymethyl methacrylate (PMMA) is widely used for the fabrication of removable prostheses. Recently, zirconium oxide nanoparticles (nano-ZrO 2 ) have been added to improve some properties of PMMA, but their effect on the optical properties and tensile strength are neglected. The aim of this study was to investigate the effect of nano-ZrO 2 addition on the translucency and tensile strength of the PMMA denture base material. Eighty specimens (40 dumbbell-shaped and 40 discs) were prepared out of heat-polymerized acrylic resin and divided into four groups per test (n=10). The control group for each test included unreinforced acrylic, while the test groups were reinforced with 2.5, 5, and 7.5 wt% nano-ZrO 2 . Acrylic resin was mixed according to manufacturer's instructions, packed, and processed by conventional method. After polymerization, all specimens were finished, polished, and stored in distilled water at 37°C for 48±2 hours. Tensile strength (MPa) was evaluated using the universal testing machine while the specimens' translucency was examined using a spectrophotometer. Statistical analysis was carried out by SPSS using the paired sample t -test ( p ≤0.05). A scanning electron microscope was used to analyze the morphological changes and topography of the fractured surfaces. This study showed that the mean tensile strength of the PMMA in the test groups of 2.5%NZ, 5%NZ, and 7.5%NZ was significantly higher than the control group. The tensile strength increased significantly after nano-ZrO 2 addition, and the maximum increase seen was in the 7.5%NZ group. The translucency values of the experimental groups were significantly lower than those of the control group. Within the reinforced groups, the 2.5%NZ group had significantly higher translucency values when compared to the 5%NZ and 7.5%NZ groups. The addition of nano-ZrO 2 increased the tensile strength of the denture base acrylic. The increase was directly proportional to the nano-ZrO 2 concentration. The

  8. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures

    Directory of Open Access Journals (Sweden)

    Bogna Stawarczyk

    2017-12-01

    Full Text Available The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x-, y- and z-axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the

  9. The effect of the accelerated aging on the mechanical properties of the PMMA denture base materials modified with itaconates

    Directory of Open Access Journals (Sweden)

    Spasojević Pavle M.

    2011-01-01

    Full Text Available This study evaluated the effect of accelerated ageing on the tensile strength, elongation at break, hardness and Charpy impact strength in commercial PMMA denture base material modified with di-methyl itaconate (DMI and di-n-butyl itaconate (DBI. The samples were prepared by modifying commercial formulation by addition of itaconates in the amounts of 2.5, 5, 7.5 and 10% by weight. After polymerization samples were characterized by FT-IR and DSC analysis while residual monomer content was determined by HPLC-UV. Accelerated ageing was performed at 70°C in water for periods of 7, 15 and 30 days. Tensile measurements were performed using Instron testing machine while the hardness of the polymerized samples was measured by Shore D method. The addition of itaconate significantly reduces the residual MMA. Even at the small amounts of added itaconates (2.5% the residual MMA content was reduced by 50%. The increase of itaconate content in the system leads to the decrease of residual MMA. It has been found that the addition of di-n-alkyl itaconates decreases the tensile strength, hardness and Charpy impact strength and increases elongation at break. Samples modified with DMI had higher values of tensile strength, hardness and Charpy impact strength compared to the ones modified with DBI. This is explained by the fact that DBI has longer side chain compared to DMI. After accelerated ageing during a 30 days period the tensile strength decreased for all the investigated samples. The addition of DMI had no effect on the material ageing and the values for the tensile strength of all of the investigated samples decreased around 20%, while for the samples modified with DBI, the increase of the amount of DBI in the polymerized material leads to the higher decrease of the tensile strength after the complete accelerated ageing period od 30 days, aulthough after the first seven days of the accelerated ageing the values of hardness have increased for all of the

  10. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    Science.gov (United States)

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Effect of Storage in Distilled Water for Three Months on the Antimicrobial Properties of Poly(methyl methacrylate Denture Base Material Doped with Inorganic Filler

    Directory of Open Access Journals (Sweden)

    Grzegorz Chladek

    2016-04-01

    Full Text Available The colonization of poly(methyl methacrylate (PMMA denture base materials by pathogenic microorganisms is a major problem associated with the use of prostheses, and the incorporation of antimicrobial fillers is a method of improving the antimicrobial properties of these materials. Numerous studies have demonstrated the initial in vitro antimicrobial effectiveness of this type of material; however, reports demonstrating the stability of these fillers over longer periods are not available. In this study, silver sodium hydrogen zirconium phosphate was introduced into the powder component of a PMMA denture base material at concentrations of 0.25%, 0.5%, 1%, 2%, 4%, and 8% (w/w. The survival rates of the gram-positive bacterium Staphylococcus aureus, gram-negative bacterium Escherichia coli and yeast-type fungus Candida albicans were established after fungal or bacterial suspensions were incubated with samples that had been previously stored in distilled water. Storage over a three-month period led to the progressive reduction of the initial antimicrobial properties. The results of this study suggest that additional microbiological tests should be conducted for materials that are treated with antimicrobial fillers and intended for long-term use. Future long-term studies of the migration of silver ions from the polymer matrix and the influence of different media on this ion emission are required.

  12. Nanocryl Coating of PMMA Complete Denture Base Materials to Prevent Scratching.

    Science.gov (United States)

    Fathi, Hawa M; Benonn, Hajer A; Johnson, Anthony

    2017-09-01

    The surface of polymethylmethacrylate (PMMA) is vulnerable to indentation by hard objects that may contribute to abrade the material surface and subject it to wear. This phenomenon promotes an increase in the surface roughness leading to microbial colonisation which can endanger the general health of wearers and damage the intra-oral prosthesis. The aim of this study is to investigate the effect of three different nanocryl coating agents (Easy Glaze, G-Coat Plus and Formulation XP) on surface roughness and thickness of PMMA material after a simulating cleaning process utilizing an electric toothbrush and three different dentifrices (pastes and immersion). Acrylic uncoated discs were used as a control group. The results showed that the G-Coat Plus coating agent had less changes in the surface roughness and thickness layer whereas the immersion cleaner revealed less abrasion effect compared with the paste cleaners which could be considered the most suitable cleaner to provide lower abrasivenes and good removal of organic debris. However, using nanofilled sealants did not demonstrate significant improvement in reducing surface roughness p ⟩ 0.05. Nevertheless, it could provide some protection against wearing to the acrylic resin surface during tooth brushing and may provide better resistance to microbial colonisation. Copyright© 2017 Dennis Barber Ltd.

  13. Effect of biofilm formation, and biocorrosion on denture base fractures.

    Science.gov (United States)

    Sahin, Cem; Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-05-01

    The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P.05). All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.

  14. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    Directory of Open Access Journals (Sweden)

    Gray Janine C

    2012-08-01

    Full Text Available Abstract Background According to the UK Adult Dental Health Survey (2009 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone. Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period. Patients will then wear each set of dentures for a period of 8 weeks (in random order during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period. Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference and confirmation period (adjusted denture preference. A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300. Discussion

  15. In vitro comparison of the tensile bond strength of denture adhesives on denture bases.

    Science.gov (United States)

    Kore, Doris R; Kattadiyil, Mathew T; Hall, Dan B; Bahjri, Khaled

    2013-12-01

    With several denture adhesives available, it is important for dentists to make appropriate patient recommendations. The purpose of this study was to evaluate the tensile bond strength of denture adhesives on denture base materials at time intervals of up to 24 hours. Fixodent, Super Poligrip, Effergrip, and SeaBond denture adhesives were tested with 3 denture base materials: 2 heat-polymerized (Lucitone 199 and SR Ivocap) and 1 visible-light-polymerized (shade-stable Eclipse). Artificial saliva with mucin was used as a control. Tensile bond strength was tested in accordance with American Dental Association specifications at 5 minutes, 3 hours, 6 hours, 12 hours, and 24 hours after applying the adhesive. Maximum forces before failure were recorded in megapascals (MPa), and the data were subjected to a 2-way analysis of variance (α=.05). All 4 adhesives had greater tensile bond strength than the control. Fixodent, Super Poligrip, and SeaBond had higher tensile bond strength values than Effergrip. All adhesives had the greatest tensile bond strength at 5 minutes and the least at 24 hours. The 3 denture bases produced significantly different results with each adhesive (Padhesives had the greatest tensile bond strength, followed by Ivocap and Eclipse. All 4 adhesives had greater tensile bond strength than the control, and all 4 adhesives were strongest at the 5-minute interval. On all 3 types of denture bases, Effergrip produced significantly lower tensile bond strength, and Fixodent, Super Poligrip, and SeaBond produced significantly higher tensile bond strength. At 24 hours, the adhesive-base combinations with the highest tensile bond strength were Fixodent on Lucitone 199, Fixodent on Eclipse, Fixodent on Ivocap, and Super Poligrip on Ivocap. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  17. A randomised controlled trial of complete denture impression materials.

    Science.gov (United States)

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, pUnilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. A Randomised Controlled Trial of complete denture impression materials

    Science.gov (United States)

    Hyde, T.P.; Craddock, H.L.; Gray, J.C.; Pavitt, S.H.; Hulme, C.; Godfrey, M.; Fernandez, C.; Navarro-Coy, N.; Dillon, S.; Wright, J.; Brown, S.; Dukanovic, G.; Brunton, P.A.

    2014-01-01

    Objectives There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Methods Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Results Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7–67.3%, p alginate as their material of choice for secondary impressions for complete dentures. Trial Registration: ISRCTN 01528038.

 This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. PMID:24995473

  19. The role of superstructure material on the stress distribution in mandibular full-arch implant-supported fixed dentures. A CT-based 3D-FEA.

    Science.gov (United States)

    Ferreira, Mayara Barbosa; Barão, Valentim Adelino; Faverani, Leonardo Perez; Hipólito, Ana Carolina; Assunção, Wirley Gonçalves

    2014-02-01

    This study evaluated the stress distribution in mandibular full-arch implant-supported fixed dentures with different veneering and metallic infrastructure materials, using three-dimensional finite element analysis. Ten models were obtained from an edentulous human mandible with a complete denture fixed by four implants. Acrylic resin (RES) and porcelain (POR) teeth were associated with infrastructures of titanium (Ti), gold (Au), silver-palladium (AgPd), chrome-cobalt (CoCr) and nickel-chrome (NiCr). A 100-N oblique was applied. The von Mises (σvM) and maximum (σmax) and minimum (σmin) principal stresses were obtained. The RES-AgPd group showed the lowest σvM values, while the RES-Ni-Cr group showed the highest. In the bone tissue, the RES-Au group was the only one that showed different σmax values with a 12% increase in comparison to the other groups which had similar stress values. In the implants, the groups with Ti, Au and AgPd infrastructures, either with porcelain or resin teeth, showed σvM values similar and lower in comparison to the groups with CoCr and NiCr infrastructures. The tooth veneering material influenced the stress values in metallic infrastructures, in which the acrylic resin had the highest values. The veneering and infrastructure materials have influence on stress values of implant-supported dentures, except for the peri-implant bone tissue. © 2013.

  20. Use of Resin-Based Provisional Material to Create the Posterior Palatal Seal in Complete Denture Definitive Impressions.

    Science.gov (United States)

    de Souza Batista, Victor Eduardo; Vechiato-Filho, Aljomar José; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos

    2017-11-17

    The purpose of this article was to present an alternative procedure using resin-based provisional material to create the posterior palatal seal (PPS). This method offers more practicality in clinical routine and increased control for addition of material to create the PPS when compared to traditional techniques such as the use of impression wax. © 2017 by the American College of Prosthodontists.

  1. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    Science.gov (United States)

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages

  2. Structural analysis of bioceramic materials for denture application

    Energy Technology Data Exchange (ETDEWEB)

    Rauf, Nurlaela, E-mail: n-rauf@fmipa.unhas.ac.id; Tahir, Dahlang; Arbiansyah, Muhammad [Dept of Physics, FMIPA-Univ. Hasanuddin Makassar Indonesia (Indonesia)

    2016-03-11

    Structural analysis has been performed on bioceramic materials for denture application by using X-ray diffraction (XRD), X-ray fluorescence (XRF), and Scanning Electron Microscopy (SEM). XRF is using for analysis chemical composition of raw materials. XRF shows the ratio 1 : 1 : 1 : 1 between feldspar, quartz, kaolin and eggshell, respectively, resulting composition CaO content of 56.78 %, which is similar with natural tooth. Sample preparation was carried out on temperature of 800 °C, 900 °C and 1000 °C. X-ray diffraction result showed that the structure is crystalline with trigonal crystal system for SiO{sub 2} (a=b=4.9134 Å and c=5.4051 Å) and CaH{sub 2}O{sub 2} (a=b=3.5925 Å and c=4.9082 Å). Based on the Scherrer’s equation showed the crystallite size of the highest peak (SiO{sub 2}) increase with increasing the temperature preparation. The highest hardness value (87 kg/mm{sup 2}) and match with the standards of dentin hardness. The surface structure was observed by using SEM also discussed.

  3. Final-impression techniques and materials for making complete and removable partial dentures.

    Science.gov (United States)

    Jayaraman, Srinivasan; Singh, Balendra P; Ramanathan, Balasubramanian; Pazhaniappan Pillai, Murukan; MacDonald, Laura; Kirubakaran, Richard

    2018-04-04

    Endentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life. To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL. We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the

  4. Physical and mechanical properties of pressure-molded and injection-molded denture base acrylics in different conditions

    Directory of Open Access Journals (Sweden)

    Yousef A Shibat Al Hamd

    2014-01-01

    Conclusion: The three tested denture base acrylics did not show any significant differences in processing shrinkage. However, ProBase Hot showed significantly lower bending deflection values than Lucitone 199 and SR-Ivocap. Compared to Lucitone 199 and SR-Ivocap, ProBase Hot is a tougher and a stiffer material. Hence, it is more likely to fracture readily if subjected to extreme loading conditions due to the accidental fall of the denture on a hard surface or if the denture wearer inadvertently bites on a particularly hard particle.

  5. Effect of long-term water immersion or thermal shock on mechanical properties of high-impact acrylic denture base resins.

    Science.gov (United States)

    Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro

    2016-01-01

    The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.

  6. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    Science.gov (United States)

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and pCAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental

  7. Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-04-01

    This position paper reviews physical and mechanical properties of thermoplastic resin used for non-metal clasp dentures, and describes feature of each thermoplastic resin in clinical application of non-metal clasp dentures and complications based on clinical experience of expert panels. Since products of thermoplastic resin have great variability in physical and mechanical properties, clinicians should utilize them with careful consideration of the specific properties of each product. In general, thermoplastic resin has lower color-stability and higher risk for fracture than polymethyl methacrylate. Additionally, the surface of thermoplastic resin becomes roughened more easily than polymethyl methacrylate. Studies related to material properties of thermoplastic resin, treatment efficacy and follow-up are insufficient to provide definitive conclusions at this time. Therefore, this position paper should be revised based on future studies and a clinical guideline should be provided. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Assessment of the impact strength of the denture base resin polymerized by various processing techniques

    Directory of Open Access Journals (Sweden)

    Rajashree Jadhav

    2013-01-01

    Full Text Available Aim : To measure the impact strength of denture base resins polymerized using short and long curing cycles by water bath, pressure cooker and microwave techniques. Materials and Methods: For impact strength testing, 60 samples were made. The sample dimensions were 60 mm × 12 mm × 3 mm, as standardized by the American Standards for Testing and Materials (ASTM. A digital caliper was used to locate the midpoint of sample. The impact strength was measured in IZOD type of impact tester using CEAST Impact tester. The pendulum struck the sample and it broke. The energy required to break the sample was measured in Joules. Data were analyzed using Student′s " t" test. Results: There was statistically significant difference in the impact strength of denture base resins polymerized by long curing cycle and short curing cycle in each technique, with the long curing processing being the best. Conclusion: The polymerization technique plays an important role in the influence of impact strength in the denture base resin. This research demonstrates that the denture base resin polymerized by microwave processing technique possessed the highest impact strength.

  9. Effect of thermal shock on mechanical properties of injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Takahashi, Yutaka; Hamanaka, Ippei; Shimizu, Hiroshi

    2012-07-01

    This study investigated the effect of thermal shock on the mechanical properties of injection-molded thermoplastic denture base resins. Four thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were tested. Specimens of each denture base material were fabricated according to ISO 1567 and were either thermocycled or not thermocycled (n = 10). The flexural strength at the proportional limit (FS-PL), the elastic modulus and the Charpy impact strength of the denture base materials were estimated. Thermocycling significantly decreased the FS-PL of one of the polyamides and the PMMA and it significantly increased the FS-PL of one of the polyamides. In addition, thermocycling significantly decreased the elastic modulus of one of the polyamides and significantly increased the elastic moduli of one of the polyamides, the polyethylene terephthalate, polycarbonate and PMMA. Thermocycling significantly decreased the impact strength of one of the polyamides and the polycarbonate. The mechanical properties of injection-molded thermoplastic denture base resins changed after themocycling.

  10. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques.

    Science.gov (United States)

    Zaparolli, Danilo; Peixoto, Raniel Fernandes; Pupim, Denise; Macedo, Ana Paula; Toniollo, Marcelo Bighetti; Mattos, Maria da Glória Chiarello de

    2017-12-01

    To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt‑chromium (G3, Co-Cr, CAD/CAM) and cobalt‑chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Color stability of different denture teeth materials: an in vitro study.

    Science.gov (United States)

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  12. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    Science.gov (United States)

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  13. A simple approach to hollow maxillary complete denture fabrication: An innovative technique

    Directory of Open Access Journals (Sweden)

    Kathleen Manuela D'souza

    2017-01-01

    Full Text Available A severely atrophic maxillary arch exhibits reduced denture bearing area and increased inter-ridge distance, thus, affecting retention of the complete denture. Such clinical situations necessitate the fabrication of a hollow complete denture to reduce the weight of the prosthesis and increase retention. This article describes a simple technique to fabricate a hollow maxillary complete denture using salt and thermoplastic poly (methyl methacrylate sheet. The vacuum-formed thermoplastic matrix regulates the quantity of salt and determines its placement in the unpolymerized denture base material during the denture packing stage. The matrix lining the hollow cavity also aids to reinforce the hollow denture base.

  14. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction.

    Science.gov (United States)

    Salloum, Alaa'a M

    2016-01-01

    Tooth movement has been shown to occur during and after the processing of complete dentures. An understanding of this phenomenon may permit one to construct functional complete dentures that require less occlusal adjustment in the articulator and in the patient's mouth. The purpose of this study was to examine the effects of three different investing methods on tooth movement occurring during the processing of simulated maxillary complete dentures. Forty-five similar maxillary dentures were made using heat-polymerized acrylic resin, and assigned randomly to three experimental groups (n = 15 each) according to investing method: plaster-plaster-plaster (P-P-P), plaster-stone-stone (P-S-S), and plaster-mix (P-M). Specimens in all experimental groups were compression molded with denture base resin. Transverse interincisor (I-I) and intermolar (M-M) distances, and anteroposterior incisor-molar (LI-LM and RI-RM) distances, were measured with digital calipers at the wax denture stage (pre-polymerization) and after denture decasting (post-polymerization). Analysis of variance and Tukey's test were used to compare the results. M-M, LI-LM, and RI-RM movement was significantly greater in the P-P-P group than in the P-S-S and P-M groups; no significant difference in I-I movement was observed among groups. Transverse movement along M-M and I-I was significantly greater than anteroposterior movement in the P-P-P group; no significant difference among measurements was observed in the other two groups. The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement.

  15. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    Science.gov (United States)

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  16. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Directory of Open Access Journals (Sweden)

    Ala Hassan A. Qamheya

    2015-01-01

    Full Text Available Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC material in teeth construction to rehabilitate a complete denture wearer patient.

  17. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    Science.gov (United States)

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  18. Evaluation of Surface Characteristics of Denture Base Using Organic-Inorganic Hybrid Coating: An SEM Study.

    Science.gov (United States)

    Aa, Jafari; Mh, Lotfi-Kamran; M, Ghafoorzadeh; Sm, Shaddel

    2017-06-01

    Despite the numerous positive features of acrylic denture base, there are a number of undeniable associated disadvantages. The properties of denture base have been improved through various interventions including application of different types of filler and coatings. This study aimed to evaluate the surface roughness, thickness and coating quality of organic-inorganic coating on the denture base through scanning electron microscopy. Moreover, the colour change was evaluated visually. The organic-inorganic hybrid coatings were prepared. Acrylic discs of 10×10 mm were fabricated. The test discs were dipped in the hybrid coating and cured. In order to evaluate the surface roughness and coating thickness, the surface and cross-section of the samples in both coated and control groups were subjected to scanning electron microscopy. The colour change and transparency were visually evaluated with naked eyes. The data were statistically analyzed by student's t test. The hybrid materials perfectly covered all the surfaces of acrylic resin and established proper thickness. The coated group seemed smoother and flatter than the control group; however, the difference was not statistically significant ( for all parameters p > 0.05). It was quite a thin coating and no perceptible colour change was observed. The hybrid coating maintained good binding, caused no noticeable discoloration, and thoroughly covered the acrylic resin surface with uniform delicate thickness. It also slightly improved the acrylic resin surface roughness.

  19. Determining color difference thresholds in denture base acrylic resin.

    Science.gov (United States)

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Zheng, Gang

    2015-11-01

    In restorative prostheses, color is important, but the choice of color difference formula used to quantify color change in acrylic resins is not straightforward. The purpose of this in vitro study was to choose a color difference formula that best represented differences between the calculated color and the observed imperceptible to unacceptable color and to determine the corresponding perceptibility and acceptability threshold of color stability for denture base acrylic resins. A total of 291 acrylic resin denture base plates were fabricated and subjected to radiation tests from zero to 42 hours in accordance with ISO 7491:2000. Color was measured with a portable spectrophotometer, and color differences were calculated with 3 International Commission on Illumination (CIE) formulas: CIELab, CMC(1:1), and CIEDE2000. Thirty-four observers with no deficiencies in color perception participated in psychophysical perceptibility and acceptability assessments under controlled conditions in vitro. These 2 types of assessments were regressed to each observer by each formula to generate receiver operator characteristic (ROC) curves. Areas under the curves (AUCs) were then calculated and analyzed to exclude observers with poor color discrimination. AUCs were subjected to 1-way ANOVA (α=.05) to deter the statistical significance of discriminability among the 3 formulas in terms of perceptibility and acceptability judgments. Student-Newman-Keuls tests (α=.05) were used for post hoc comparison. CMC(1:1) and CIEDE2000 formulas performed better for imperceptible to unacceptable color differences, with corresponding CMC(1:1) and CIEDE2000 values for perceptibility of 2.52 and 1.72, respectively, and acceptability thresholds of 6.21 and 4.08, respectively. Formulas CMC(1:1) and CIEDE2000 possess higher discriminability than that of CIELab in the assessment of perceptible color difference threshold of denture base acrylic resin. A statistically significant difference exists

  20. Efficacy of commercial and household denture cleansers against Candida albicans adherent to acrylic denture base resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    M Nanditha Kumar

    2012-01-01

    Conclusion: Within the limitations of this in vitro study, denture cleansers were found to be effective in reducing C albicans cells adhering to dentures. The commercial denture cleansers (Fittydent® and Clinsodent® were more effective than household denture cleansers (vinegar and diluted vinegar.

  1. Silver distribution and release from an antimicrobial denture base resin containing silver colloidal nanoparticles.

    Science.gov (United States)

    Monteiro, Douglas Roberto; Gorup, Luiz Fernando; Takamiya, Aline Satie; de Camargo, Emerson Rodrigues; Filho, Adhemar Colla Ruvolo; Barbosa, Debora Barros

    2012-01-01

    The aim of this study was to evaluate a denture base resin containing silver colloidal nanoparticles through morphological analysis to check the distribution and dispersion of these particles in the polymer and by testing the silver release in deionized water at different time periods. A Lucitone 550 denture resin was used, and silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The acrylic resin was prepared in accordance with the manufacturers' instructions, and silver nanoparticle suspension was added to the acrylic resin monomer in different concentrations (0.05, 0.5, and 5 vol% silver colloidal). Controls devoid of silver nanoparticles were included. The specimens were stored in deionized water at 37°C for 7, 15, 30, 60, and 120 days, and each solution was analyzed using atomic absorption spectroscopy. Silver was not detected in deionized water regardless of the silver nanoparticles added to the resin and of the storage period. Micrographs showed that with lower concentrations, the distribution of silver nanoparticles was reduced, whereas their dispersion was improved in the polymer. Moreover, after 120 days of storage, nanoparticles were mainly located on the surface of the nanocomposite specimens. Incorporation of silver nanoparticles in the acrylic resin was evidenced. Moreover, silver was not detected by the detection limit of the atomic absorption spectrophotometer used in this study, even after 120 days of storage in deionized water. Silver nanoparticles are incorporated in the PMMA denture resin to attain an effective antimicrobial material to help control common infections involving oral mucosal tissues in complete denture wearers. © 2011 by the American College of Prosthodontists.

  2. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  3. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks.

    Science.gov (United States)

    Norvell, Nicholas G; Korioth, Tom V; Cagna, David R; Versluis, Antheunis

    2018-02-08

    Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were

  4. Inhibitory effect of zirconium oxide nanoparticles on Candida albicans adhesion to repaired polymethyl methacrylate denture bases and interim removable prostheses: a new approach for denture stomatitis prevention.

    Science.gov (United States)

    Gad, Mohammed M; Al-Thobity, Ahmad M; Shahin, Suliman Y; Alsaqer, Badar T; Ali, Aiman A

    2017-01-01

    addition of zirconia nanoparticles to cold-cured acrylic resin is an effective method for reducing Candida adhesion to repaired polymethyl methacrylate (PMMA) denture bases and cold-cured removable prosthesis. Based on the results of the current study, zirconia nanoparticles have an antifungal effect, which could be incorporated in the repair material for repairing denture bases and in PMMA removable prostheses as a possible approach for denture stomatitis prevention.

  5. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    Science.gov (United States)

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  6. Controlling fungal biofilms with functional drug delivery denture biomaterials.

    Science.gov (United States)

    Wen, Jianchuan; Jiang, Fuguang; Yeh, Chih-Ko; Sun, Yuyu

    2016-04-01

    Candida-associated denture stomatitis (CADS), caused by colonization and biofilm-formation of Candida species on denture surfaces, is a significant clinical concern. We show here that modification of conventional denture materials with functional groups can significantly increase drug binding capacity and control drug release rate of the resulting denture materials for potentially managing CADS. In our approach, poly(methyl methacrylate) (PMMA)-based denture resins were surface grafted with three kinds of polymers, poly(1-vinyl-2-pyrrolidinone) (PNVP), poly(methacrylic acid) (PMAA), and poly(2-hydroxyethyl methacrylate) (PHEMA), through plasma-initiated grafting polymerization. With a grafting yield as low as 2 wt%, the three classes of new functionalized denture materials showed significantly higher drug binding capacities toward miconazole, a widely used antifungal drug, than the original PMMA denture resin control, leading to sustained drug release and potent biofilm-controlling effects against Candida. Among the three classes of functionalized denture materials, PNVP-grafted resin provided the highest miconazole binding capability and the most powerful antifungal and biofilm-controlling activities. Drug binding mechanisms were studied. These results demonstrated the importance of specific interactions between drug molecules and functional groups on biomaterials, shedding lights on future design of CADS-managing denture materials and other related devices for controlled drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Overdenture retained by teeth using a definitive denture base technique: a case report.

    Science.gov (United States)

    Nascimento, D F F; dos Santos, J F F; Marchini, L

    2010-09-01

    This paper presents a technique involving the use of a definitive denture base to make overdentures. Cores with ball attachments were cemented over remaining lower teeth. Impressions of the edentulous maxilla and mandible were taken to obtain a definitive acrylic resin base. The definitive base of the mandible was perforated at the location of ball attachments and its female components were fixed to the base using acrylic resin directly in the patient's mouth. Wax rims were then made, jaw relationships recorded, teeth mounted and tried in, and the dentures were cured. This technique allowed for easy fixing of female components and better retention during the recording of jaw relationships, and can also be used in the construction of implant retained dentures.

  8. Novel denture-cleaning system based on hydroxyl radical disinfection.

    Science.gov (United States)

    Kanno, Taro; Nakamura, Keisuke; Ikai, Hiroyo; Hayashi, Eisei; Shirato, Midori; Mokudai, Takayuki; Iwasawa, Atsuo; Niwano, Yoshimi; Kohno, Masahiro; Sasaki, Keiichi

    2012-01-01

    The purpose of this study was to evaluate a new denture-cleaning device using hydroxyl radicals generated from photolysis of hydrogen peroxide (H2O2). Electron spin resonance analysis demonstrated that the yield of hydroxyl radicals increased with the concentration of H2O2 and light irradiation time. Staphylococcus aureus, Pseudomonas aeruginosa, and methicillin-resistant S aureus were killed within 10 minutes with a > 5-log reduction when treated with photolysis of 500 mM H2O2; Candida albicans was killed within 30 minutes with a > 4-log reduction with photolysis of 1,000 mM H2O2. The clinical test demonstrated that the device could effectively reduce microorganisms in denture plaque by approximately 7-log order within 20 minutes.

  9. Effect of repair resin type and surface treatment on the repair strength of heat-polymerized denture base resin.

    Science.gov (United States)

    Alkurt, Murat; Yeşil Duymuş, Zeynep; Gundogdu, Mustafa

    2014-01-01

    Acrylic resin denture fracture is common in prosthodontic practice. When fractured denture bases are repaired, recurrent fractures frequently occur at the repair surface interface or adjacent areas. The purpose of this study was to evaluate the effect of different surface treatments on the flexural strength of the acrylic resin denture base repaired with heat-polymerized acrylic resin, autopolymerizing resin, and light-polymerized acrylic resin. Ninety-six specimens of heat-polymerized acrylic resin were prepared according to the American Dental Association Specification No. 12 (65.0 × 10.0 × 2.5 mm) and sectioned into halves to create a repair gap (3.0 × 10 × 2.5 mm). The sectioned specimens were divided into 3 groups according to their repair materials. The specimens from each group were divided into 4 subgroups according to their surface treatments: a control group without any surface treatment; an experimental group treated with methyl methacrylate monomer (MMA group); an experimental group treated with airborne-particle abrasion with aluminum oxide particles of 250-μm particle size (abrasion group); and an experimental group treated with erbium:yttrium-aluminum-garnet laser (laser group). After the surface treatments, the 3 materials were placed into the repair gaps and then polymerized. After all of the specimens had been ground and polished, they were stored in distilled water at 37°C for 1 week and subjected to a 3-point bend test. Data were analyzed with a 2-way analysis of variance, and the Tukey honestly significant difference test was performed to identify significant differences (α=.05). The effects of the surface treatments and repair resins on the surface of the denture base resin were examined with scanning electron microscopy. Significant differences were found among the groups in terms of repair resin type (P<.001). All surface-treated specimens had higher flexural strength than controls, except the surface treated with the methyl

  10. Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution.

    Science.gov (United States)

    Sato, Maki; Suzuki, Yasunori; Kurihara, Daisuke; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2013-04-01

    This study explored the relationship between implant support and the denture-supporting area by comparing the stability of an implant-supported distal extension removable partial denture and a conventional distal extension removable partial denture. A model simulating a mandibular bilateral distal extension missing (#34-37 and #44-47) was fabricated using silicone impression material as soft tissue (2 mm thick) on an epoxy resin bone model. The denture base was reduced by 5 mm cutting part of both the retromolar pad and the lingual border. Loads of up to 5 kg were applied, and the pressure and displacement of the RPDs were simultaneously measured and analyzed using the Wilcoxon test (αremovable partial denture (ISRPD) was significantly less than on the conventional RPD (CRPD). As the supporting area of the denture base decreased, the pressure and the denture displacement of the CRPD were greater than for the ISRPD. This study indicated that implant placement at the distal edentulous ridge can prevent denture displacement of the distal extension bases, regardless of the supporting area of the denture base. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Investigating oral health-related quality of life and self-perceived satisfaction with partial dentures.

    Science.gov (United States)

    Abuzar, Menaka A; Kahwagi, Esperance; Yamakawa, Takeshi

    2012-05-01

    To investigate the prevalence and severity of oral health-related quality of life in patients treated with removable partial dentures at a publicly-funded dental hospital. The association between patients' demographic profiles, denture-related, variables and oral health-related quality of life was also investigated. A questionnaire was designed to investigate the use and satisfaction of removable partial dentures, and oral health-related quality of life of removable partial denture wearers using the Oral Health Impact Profile-14. The questionnaire was administered to 740 randomly-selected patients who received removable partial dentures during 2005-2008. The response rate was 31.35%. Non-parametric tests and a logistic regression model were used to analyze the association between denture-related variables and oral health-related quality of life. A question on symptoms unrelated to dentures was also analyzed. The Oral Health Impact Profile-14 prevalence calculated was 43.1%. The removable partial denture experience and frequency of use was inversely associated with Oral Health Impact Profile-14 scores. Metal-based removable partial dentures were associated with lower Oral Health Impact Profile prevalence and severity scores. No significant association was found between demographic profile, circumstance for provision of removable partial dentures and Oral Health Impact Profile-14 score. The participants of this study indicated that perceived denture performance, removable partial dentures material, experience, and frequency of use are associated with oral health-related quality of life. © 2012 Blackwell Publishing Asia Pty Ltd.

  12. Flexural properties and impact strength of denture base resins reinforced with micronized glass flakes

    Directory of Open Access Journals (Sweden)

    Ronak H Choksi

    2016-01-01

    Conclusion: Flexural strength of unmodified PMMA denture base resin decreases with increase in the concentration of glass flakes. Impact strength does not show any significant change at 5% concentration of glass flakes and impact strength significantly reduces with the addition of glass flakes in 10% and 20%.

  13. Denture hygiene knowledge and practice amongst patients in a ...

    African Journals Online (AJOL)

    Aim: To assess patients' knowledge on denture hygiene and the hygiene methods used for cleaning removable partial dentures. Methods: This was a ... Other information obtained were the duration of denture use, frequency of denture cleaning and type of material used for denture cleaning. Results: The age of the ...

  14. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    OpenAIRE

    Nam, Ki-Young

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transm...

  15. Comparative clinical evaluation of removable partial dentures made of two different materials in Kennedy Applegate class II partially edentulous situation.

    Science.gov (United States)

    Hundal, Maninder; Madan, Rajesh

    2015-12-01

    Cast Chromium Cobalt alloy has been the material of choice for fabricating Removable Partial Dentures (RPDs) but has certain drawbacks. Newer materials like the flexible Nylon based Super Polyamide have been introduced to overcome these drawbacks. The present study has compared the above two materials for nine clinical parameters. The study was carried out on 30 patients presenting with a Kennedy Applegate class II partially edentulous situation who were divided into two equal groups and clinically assessed. Statistically significant results were obtained in favor of flexible RPDs, in the parameters of 'aesthetics' and 'overall patient satisfaction'. Both groups showed more or less similar values for 'frequency of fracture of the prosthesis during usage' with the incidence being slightly higher for patients wearing the cast RPDs. The clinical parameters of 'oral soft tissue tolerance', 'gingival health', 'periodontal health' and 'adaptability in areas with undercut' were statistically at par for all the 30 patients thus suggesting the comparable biocompatibility of the two materials. The highlight of this study was the relative ease in fabrication of the flexible RPDs as compared to the cast RPDs. Based on the favorable clinical results of this study, it can be summarized that the flexible RPDs is a viable alternative to cast RPDs in Kennedy Applegate class II partially edentulous situation in the short term.

  16. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment

    Directory of Open Access Journals (Sweden)

    Harsimran Kaur

    2015-01-01

    Full Text Available Purpose: To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Materials and Methods: Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P and rest 80 to heat-cured resilient liner (Molloplast B. Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm in the space provided by a spacer of 3 mm, thermocycled (5-55°C for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. Results: One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student′s t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Conclusion: Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  17. Denture Adhesives

    Science.gov (United States)

    ... Devices Products and Medical Procedures Dental Devices Denture Adhesives Share Tweet Linkedin Pin it More sharing options ... Wearers Reporting Problems to the FDA Background Denture adhesives are pastes, powders or adhesive pads that may ...

  18. The Antifungal Activity and Cytotoxicity of Silver Containing Denture ...

    African Journals Online (AJOL)

    2015-10-30

    Oct 30, 2015 ... Objective: Denture base materials are susceptible to fungal adhesion, which is an important .... (Shimadzu Corp., Kyoto, Japan) to achieve a wavelength ..... assay for detection of cytotoxicity and prediction of acute toxicity.

  19. A comparative study of retention of complete denture base with different types of posterior palatal seals – an in vivo study

    Directory of Open Access Journals (Sweden)

    Chandu GS

    2014-11-01

    Full Text Available GS Chandu,1 BS Hema,2 Harsh Mahajan,1 Antriksh Azad,2 Ipsita Sharma,3 Anurag Azad4 1Department of Prosthodontics, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 2Department of Conservative Dentistry, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 3Department of Oral Pathology, RKDF Dental college and Research centre, Bhopal, Madhya Pradesh, India; 4Department of Oral and Maxillofacial Surgery, Bhabha College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India Aim: To evaluate retention of complete denture base with different types of posterior palatal seals. Material and methods: Ten male patients between the age group of 50 years to 60 years were selected for the study. After the primary and secondary impressions were taken, five casts were made including a cast without posterior palatal seal, a cast with single bead posterior palatal seal, a cast with double bead posterior palatal seal, a cast with butterfly shaped posterior palatal seal, and a cast with posterior palatal seal with low fusing compound by functional method. Results: It was observed that retention increased up to 108% in the posterior palatal seal with low fusing compound with functional method and the posterior palatal seal that was obtained by using functional method provided greater retention than a denture base without posterior palatal seal. Conclusion: It was concluded that the incorporation of a posterior palatal seal is important for obtaining optimum retention of the maxillary complete denture. Keywords: posterior palatal seal, denture base, complete denture, functional method

  20. Effects of trimethylsilane plasma coating on the hydrophobicity of denture base resin and adhesion of Candida albicans on resin surfaces.

    Science.gov (United States)

    Liu, Tianshuang; Xu, Changqi; Hong, Liang; Garcia-Godoy, Franklin; Hottel, Timothy; Babu, Jegdish; Yu, Qingsong

    2017-12-01

    Candida-associated denture stomatitis is the most common oral mucosal lesion among denture wearers. Trimethylsilane (TMS) plasma coating may inhibit the growth of Candida albicans on denture surfaces. The purpose of this in vitro study was to investigate whether TMS plasma coatings can effectively reduce C albicans adhesion on denture base acrylic resin surfaces. Sixty denture base acrylic resin disks with smooth and rough surfaces were prepared and were either left untreated (control group) or coated with TMS monomer (experimental group) by using plasma. Contact angles were measured immediately after TMS plasma coating. The morphology of C albicans adhesion was observed with scanning electron microscopy (SEM). Energy-dispersive spectroscopy (EDS) was used to characterize the elemental composition of the specimen surface. An adhesion test was performed by incubating the resin disk specimens in C albicans suspensions (1×10 7 cells/mL) at 37°C for 24 hours and further measuring the optical density of the C albicans by using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay test. One-way ANOVA and 2-way ANOVA were followed by a post hoc test analysis (α=.05). The group with TMS coating exhibited a more hydrophobic surface than the control group. EDS analysis revealed successful TMS plasma coating. The difference in the mean contact angles between the uncoated group and the TMS-coated group was statistically significant (Pcoating than on the surfaces of the experimental group. In the adhesion test, the amount of C albicans adhering to the surface of denture base resin with the TMS coating was significantly less than that on the surfaces without TMS coating (Pcoating significantly reduced the adhesion of C albicans to the denture base resin and may reduce denture stomatitis. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Going Beyond the Conventional Approach - Liquid Supported Denture: A Case Report

    Directory of Open Access Journals (Sweden)

    Dipti S Shah

    2013-01-01

    Full Text Available Background: The concept of conditioning oral mucosa has gained momentum over the last few years. Different tissue conditioning materials and soft liners have been used for this purpose. But the limitations of these materials has led to the introduction of liquid-supported dentures, which is a newer alternative to conventional complete denture prosthesis in cases with inflamed tissues, atrophic and severely resorbed edentulous ridges. Liquid supported Denture consists of a base which is covered with a preshaped close fitting flexible foil containing a thin film of high viscosity liquid which cushions the underlying tissues. This case report describes fabrication of liquid-supported dentures for patients with compromised tissues.

  2. A clinical evaluation denture adhesives used by patients with xerostomia.

    Science.gov (United States)

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  3. Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length

    OpenAIRE

    Yoo, Jin Suk; Kwon, Kung-Rock; Noh, Kwantae; Lee, Hyeonjong; Paek, Janghyun

    2017-01-01

    PURPOSE The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was...

  4. A comparison of mandibular denture base deformation with different impression techniques for implant overdentures.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; El-Waseef, Fatma Ahmad; Al-Mahdy, Yasmeen Fathy; Fouad, Mohammed Mohammed

    2013-08-01

    This study aimed to evaluate mandibular denture base deformation along with three impression techniques used for implant-retained overdenture. Ten edentulous patients (five men and five women) received two implants in the canine region of the mandible and three duplicate mandibular overdentures which were constructed with mucostatic, selective pressure, and definitive pressure impression techniques. Ball abutments and respective gold matrices were used to connect the overdentures to the implants. Six linear strain gauges were bonded to the lingual polished surface of each duplicate overdenture at midline and implant areas to measure strain during maximal clenching and gum chewing. The strains recorded at midline were compressive while strains at implant areas were tensile. Clenching recorded significant higher strain when compared with gum chewing for all techniques. The mucostatic technique recorded the highest strain and the definite pressure technique recorded the lowest. There was no significant difference between the strain recorded with mucostatic technique and that registered with selective pressure technique. The highest strain was recorded at the level of ball abutment's top with the mucostatic technique during clenching. Definite pressure impression technique for implant-retained mandibular overdenture is associated with minimal denture deformation during function when compared with mucostatic and selective pressure techniques. Reinforcement of the denture base over the implants may be recommended to increase resistance of fracture when mucostatic or selective pressure impression technique is used. © 2012 John Wiley & Sons A/S.

  5. The improvement of the mechanical properties of PMMA denture base by Al2O3 particles with nitrile rubber

    Science.gov (United States)

    Alhareb, Ahmed Omran; Akil, Hazizan Md; Ahmad, Zainal Arifin

    2017-07-01

    Poly methyl methacrylate (PMMA) is mostly used for fabrication of denture base by heat-curing technique. Therefore, the purpose of this study is to investigate the effect of Al2O3 filler as toughening particles together with nitrile butadiene rubber (NBR) particles as impact modifier were used to reinforce PMMA denture base materials on the impact strength (IS) and fracture toughness (KIC). PMMA powder was mixed with liquid methyl methacrylate (MMA) and ethylene glycol dimethacrylate (EGDMA) as crosslinking agent. The powder components are PMMA, benzoyl peroxide, NBR (5, 7.5 and 10 wt%), and Al2O3 filler (5 wt%) treated by silane. The liquid components are 90% of methyl methacrylate and 10 % ethylene glycol dimethacryate. FTIR analyses confirmed that the Al2O3 filler was successfully treated with silane as coupling agent. The morphology of fracture surfaces was characterized using field emission scanning electron microscopy (FESEM). The results shown that IS and KIC improved significantly when using treated the Al2O3 filler. IS has increased to 56% (8.26 KJ/m2) and 73% (2.77 MPa.m1/2) for KIC when treated Al2O3 filler compared to unreinforced PMMA matrix. Statistical analyses of data results were significantly improved (PNBR with treated Al2O3 filler compared to other the compositions.

  6. Oral health-related quality of life of edentulous patients after complete dentures relining

    Directory of Open Access Journals (Sweden)

    Krunić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Tooth loss affects oral health-related life quality. More than a third of edentulous patients are not fully satisfied with their complete dentures and mainly complain of insufficient stability, retention, and pain during mastication. Solving the problem may include relining by materials that are based on silicone or acrylic. The aim of this study was to determine the level of patients’ satisfaction before and after relining upper dentures with soft and rigid liners. Methods. The patients (n = 24 were divided into two study groups. Maxillary denture relining of the first group of patients was performed with hard acrylic based resins while in the second group of patients complete denture was relined with a silicone-based soft liner. They were asked the questions from the specifically adapted the Oral Health Impact Profile Questionnaire for edentulous patients before and three months after relining dentures. Results. After relining the patients showed a higher degree of satisfaction with their dentures in all the tested domains (masticatory function, psychological discomfort, social disability and retention and hygiene. The patients with soft denture relines were more satisfied. Conclusion. Relining of maxillary complete dentures significantly positively impacts the quality of life of patients in all the tested domains (masticatory function, psychological discomfort, social disability, pain and oral hygiene. Better results were achieved using a silicone-based soft liner, which recommends it as the material of choice for relining dentures.

  7. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  8. A survey of U.S. prosthodontists and dental schools on the current materials and methods for final impressions for complete denture prosthodontics.

    Science.gov (United States)

    Petrie, Cynthia S; Walker, Mary P; Williams, Karen

    2005-12-01

    The purpose of this study was to survey members of The American College of Prosthodontists (ACP) to evaluate current materials and methods for final impressions for complete denture prosthodontics in the United States. In addition, those methods were compared with methods and materials taught in U.S. dental schools via a second survey sent to the chairpersons of prosthodontic/restorative departments. An anonymous questionnaire was mailed to all 1762 active ACP members in the United States in 2003. A slightly modified questionnaire was also distributed to chairpersons of prosthodontic/restorative departments in the 54 U.S. dental schools. Data analysis was performed via frequency distribution and chi-square statistics. Nine hundred and forty-five questionnaires were returned by members of the ACP (54% return rate) and 42 questionnaires were returned by the U.S. dental schools (78% return rate). The majority of the reporting prosthodontists (88%) and dental schools (98%) use a border-molded custom tray for final impressions for complete denture prosthodontics. The most popular material for border molding was plastic modeling compound (67% of reporting ACP members, and 95% of the responding dental schools). Variability of the materials used for final impressions was observed, with the most popular materials being polyvinylsiloxane for the ACP members (36%) and polysulfide for the dental schools (64%). Statistically significant differences were found in the materials used for border molding by prosthodontists based on the time elapsed since completion of prosthodontic training. No differences were found in the materials used for impression of edentulous arches based on years of experience. Geographic location did not influence the materials and methods used by prosthodontists for complete denture final impressions. There was variability of the materials and techniques used for final impressions by ACP members and dental schools; however, overall there was an agreement

  9. Preparation and characterization of ZnO-PMMA resin nanocomposites for denture bases.

    Science.gov (United States)

    Cierech, Mariusz; Wojnarowicz, Jacek; Szmigiel, Dariusz; Bączkowski, Bohdan; Grudniak, Anna Maria; Wolska, Krystyna Izabela; Łojkowski, Witold; Mierzwińska-Nastalska, Elżbieta

    2016-01-01

    The aim of the paper was to investigate the antifungal activity of zinc oxide nanoparticles (ZnONPs) against Candida albicans. Some attempts have been made to find out the best way to introduce ZnONPs into polymethyl methacrylate (PMMA) resin material and to determine some parameters of a newly formed composite. Zinc oxide nanoparticles were manufactured and their basic physical parameters were determined (average particle size, density, specific surface area). Minimal inhibitory concentration (MIC) of ZnONPs was determined for the Candida albicans standard strain. The average size of ZnO conglomerates in the monomer solution of PMMA resin was measured using a dynamic light scattering instrument. PMMA resin samples with incorporated ZnONPs were produced. The morphology of nanopowder and the newly formed composite was examined under a scanning electron microscope (SEM). In addition, the roughness parameter of PMMA resin material was investigated before and after ZnONPs modification. Nanopowder with the average particle size of 30 nm, density of 5.24 g/cm3 and surface area of 39 m2/g was obtained. MIC was determined at the level of 0.75 mg/mL. The average size of ZnO conglomerates in the monomer solution of acrylic resin dropped by 11 times after ultrasound activation. SEM examination of a newly formed composite showed a successful introduction of ZnONPs confirmed by the energy dispersive X-ray spectroscopy (EDS) analysis. There were no statistically significant differences in the biomaterial roughness before and after the modification of ZnONPs. Zinc oxide nanoparticles were successfully incorporated into acrylic resin used for the production of denture bases. The presence of nanoparticles with sizes below 100 nm was confirmed. Nevertheless a newly created composite needs to be further investigated to improve its homogeneity, and to check its microbiological properties, strength and biocompatibility prior to its possible clinical use.

  10. A follow-up study on removable partial dentures in undergraduate program: part I. participants and denture use by telephone survey.

    Science.gov (United States)

    Yoshida, Eiko; Fueki, Kenji; Igarashi, Yoshimasa

    2011-07-04

    The aim of this study was to investigate the clinical outcome of removable partial dentures (RPDs) designed to minimize denture mobility during function. Using archived files of the undergraduate program between 2003 and 2005 at Tokyo Medical and Dental University, a list of 169 patients treated with 184 RPDs was created. The RPDs had either an acrylic resin-base or a cobalt-chrome framework-base. Two examiners telephoned all the listed patients and interviewed 118 patients (70%) regarding the use of their RPDs. Of 118 patients, 42 (36%) had stopped using, mainly due to problems with abutment teeth in resin-based dentures, and replacement in cobalt-chrome-based dentures. There was no significant difference in mean age, gender distribution, mean number of remaining/abutment teeth, distribution of denture arch, and Kennedy classification between denture use and nonuse groups (p>0.05). The nonuse group showed a significantly higher percentage of resin-base compared to the use group (p = 0.006). Logistic regression analysis indicated that resin-base was a significant risk factor for nonuse (p = 0.008). The present findings suggest that abutment teeth should be selected carefully, especially in this type of resin-based RPDs, and that the denture base material may be a critical factor which determines denture use.

  11. Complete Denture Impression Techniques Practiced by Private Dental Practitioners: A Survey

    OpenAIRE

    Kakatkar, Vinay R.

    2012-01-01

    Impression making is an important step in fabricating complete dentures. A survey to know the materials used and techniques practiced while recording complete denture impressions was conducted. It is disheartening to know that 33 % practitioners still use base plate custom trays to record final impressions. 8 % still use alginate for making final impressions. An acceptable technique for recording CD impressions is suggested.

  12. Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.

    Science.gov (United States)

    ELsyad, Moustafa Abdou; Errabti, Hatem Mokhtar; Mustafa, Aisha Zakaria

    2016-12-01

    The aim of this in vitro study was to evaluate and compare mandibular denture base deformation between ball and Locator attachments of implant-retained overdentures. An experimental acrylic model covered with resilient silicone mucosal simulation was constructed. Two laboratory implants were placed in the canine areas of the model. Two duplicate experimental overdentures were constructed and connected to the implants with either ball (GI) or Locator (GII) attachments. To measure overdenture strain around the attachments, 3 strain gauges were attached to the lingual polished surface of the overdentures opposite to the right implant (loading side) 2 mm above the attachment level (Ch1), at the attachment level (Ch2), and 2 mm below the attachment level (Ch3). Another 3 gauges were bonded opposite to the left implant (non-loading side) in the same manner (Ch6, Ch7, and Ch8). To measure strain at the midline of the overdentures, two strain gauges were attached in the midline at 5 mm intervals (Ch4 and Ch5). A universal testing device was used to deliver vertical static load of 50 N unilaterally and bilaterally to the first molar area to measure strain using a multi-channel digital strain meter. During bilateral load application, GII recorded higher compressive strains than GI at the majority of channels. During unilateral load application, GI recorded higher tensile strains at Ch1, Ch2, and Ch3, and GII recorded higher strains than GI at Ch6, Ch7, and Ch8. During bilateral loading the highest strain was concentrated at Ch5 for both groups. During unilateral loading, the highest strain was concentrated at Ch2 for GI, and at Ch5 for GII. Ball attachments for implant-retained overdentures were associated with significant mandibular denture base deformation over the implants compared to Locator attachments. Therefore, denture base reinforcement may be recommended with ball attachmentz to increase fracture resistance of the base. © 2015 by the American College of

  13. Prosthetic Rehabilitation by Palatal Hollow Bulb Obturator with Cast Metal Denture Base: A Case Report

    Directory of Open Access Journals (Sweden)

    George Francis

    2015-01-01

    Full Text Available Background: Prosthetic reconstruction of partial maxillectomy defects is a challenging procedure that requires multidisciplinary expertise to achieve an acceptable function, speech and esthetics. This procedure improves the quality of life for the patient as a normal individual. Obturation of the defect depends on its volume and position of remaining hard and soft tissues which determine the retention, stability and support for the prosthesis. The prosthesis should be simple to handle, easy to maintain, biocompatible, light in weight and convenient for future adjustments. This case report describes a clinical case of partial maxillectomy which was successfully rehabilitated with a definitive closed hollow bulb obturator and cast metal denture base.

  14. The effect of submersion denture base acrylic resin in a betel leaf ekstract solution against growth Candida albicans

    Directory of Open Access Journals (Sweden)

    Andi Izham

    2016-06-01

    Full Text Available Denture base is a protesa which replace some or all of the lost original teeth and surrounding tissues. The Pupose of making protesa is for restore the function, appearance, comfort and impaired health result lost teeth. One part of the denture base is base plate. Microorganisms are often found in the oral cavity is Candida albicans (C.albicans approximately 40% in the oral cavity.C.albicans can penetrate the acrylic resin that can infect the soft tissue and is the cause of denture stomatitis therefore the disinfection of denture base is a important factor that must be done. In general betel leaves contant up to 4.2% essential oil compounds and phenyl propanoid and tannin. These compounds is a antimicroba and antifungal which can inhibit the growth of several type of bacteria among others Escherichia coli, Salmonella sp, Staphylococcus aurens, Klebstella, Pasteurella and can turn off the C.albicans. The purpose of the research is to determine how the effect of submersion denture base acrylic resin in a betel leaf ekstract solution against growth C.albicans.Type of research is an experimental laboratory with a longitudinal design (follow-up study. The sampling method used is total sampling. The results showed that the number of C.albicans colonies n denture base acrylic resin which soaked betel leaf extract solution that the dilution 10-1  with consentration 2.5% total colony count is 2 and the results 2.0 x 101 CFU/ml, on a control solution that the dilution 10-2 total colony 355 and the result 3.55 x 104 CFU/ml, that the dilution  10-3 total colony 62 and the result 6.2 x 104 CFU/ml.

  15. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study.

    Science.gov (United States)

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-06-01

    The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

  16. Influence of incorporation of ZrO2 nanoparticles on the repair strength of polymethyl methacrylate denture bases

    Directory of Open Access Journals (Sweden)

    Gad MM

    2016-10-01

    Full Text Available Mohammed M Gad,1 Ahmed Rahoma,2,3 Ahmad M Al-Thobity,1 Aws S ArRejaie4 1Department of Substitutive Dental Sciences, 2Department of Restorative Dental Sciences, College of Dentistry, University of Dammam, Dammam, Saudi Arabia; 3Department of Dental Materials, College of Dentistry, Al-Azhar University, Assiut, Egypt; 4Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia Background: Repeated fracture of the denture base is a common problem in prosthodontics, and it represents a nuisance and a time sink for the clinician. Therefore, the possibility of increasing repair strength using new reinforcement materials is of great interest to prosthodontists.Aim of the study: This study aimed to evaluate the effects of incorporation of zirconia nanoparticles (nano-ZrO2 on the flexural strength and impact strength of repaired polymethyl methacrylate (PMMA denture bases.Materials and methods: One hundred eighty specimens of heat-polymerized acrylic resin were fabricated (90 for each test and divided into three main groups: one control group (intact specimens and two groups divided according to surface design (45° bevels and butt joints, in which specimens were prepared in pairs to create 2.5 mm gaps. Nano-ZrO2 was added to repair resin in 2.5 wt%, 5 wt%, and 7.5 wt% concentrations of acrylic powder. A three-point bending test was used to measure flexural strength, and a Charpy-type test was used to measure impact strength. Scanning electron microscopy was used to analyze the fracture surfaces and nano-ZrO2 distribution. The results were analyzed with a paired sample t-test and an unpaired t-test, with a P-value of ≤0.05 being significant.Results: Incorporation of nano-ZrO2 into the repair resin significantly increased flexural strength (P<0.05. The highest value was found in the bevel group reinforced with 7.5% nano-ZrO2, whereas the lowest value was found in the butt group reinforced with 2.5% nano

  17. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  18. Fracture toughness of heat cured denture base acrylic resin modified with Chlorhexidine and Fluconazole as bioactive compounds.

    Science.gov (United States)

    Al-Haddad, Alaa; Vahid Roudsari, Reza; Satterthwaite, Julian D

    2014-02-01

    This study investigated the impact of incorporating Chlorhexidine and Fluconazole as bioactive compounds on the fracture toughness of conventional heat cured denture base acrylic resin material (PMMA). 30 single edge-notched (SEN) samples were prepared and divided into three groups. 10% (mass) Chlorhexidine and 10% (mass) Diflucan powder (4.5% mass Fluconazole) were added to heat cured PMMA respectively to create the two study groups. A third group of conventional heat cured PMMA was prepared as the control group. Fracture toughness (3-point bending test) was carried out for each sample and critical force (Fc) and critical stress intensity factor (KIC) values measured. Data were subject to parametric statistical analysis using one-way ANOVA and Post hoc Bonferroni test (p=0.05). Fluconazole had no significant effect on the fracture toughness of the PMMA while Chlorhexidine significantly reduced the KIC and therefore affected the fracture toughness. When considering addition of a bioactive material to PMMA acrylic, Chlorhexidine will result in reduced fracture toughness of the acrylic base while Fluconazole has no effect. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Perubahan warna basis akrilik setelah penggunaan pasta pembersih gigitiruan rosella (The changes of acrylic base color after using roselle pasta denture cleanser)

    OpenAIRE

    Evan G. Tunggal; Moh. Dharmautama; Eri H. Jubhari

    2015-01-01

    This clinical experimental study was aimed to determine the effect of roselle denture cleanser paste usage on acrylic base color degradation. Acrylic base color degradation was assessed by providing roselle denture cleanser to 5 subjects to be used every day. In month 3, 6 and 9, data collection were performed by a professional photographer and assessed by CIELab system. Data were analyzed using Wilcoxon and friedman two ways. Acrylic base color, before and after pasta using, show...

  20. An ontology-driven, case-based clinical decision support model for removable partial denture design

    Science.gov (United States)

    Chen, Qingxiao; Wu, Ji; Li, Shusen; Lyu, Peijun; Wang, Yong; Li, Miao

    2016-06-01

    We present the initial work toward developing a clinical decision support model for specific design of removable partial dentures (RPDs) in dentistry. We developed an ontological paradigm to represent knowledge of a patient’s oral conditions and denture component parts. During the case-based reasoning process, a cosine similarity algorithm was applied to calculate similarity values between input patients and standard ontology cases. A group of designs from the most similar cases were output as the final results. To evaluate this model, the output designs of RPDs for 104 randomly selected patients were compared with those selected by professionals. An area under the curve of the receiver operating characteristic (AUC-ROC) was created by plotting true-positive rates against the false-positive rate at various threshold settings. The precision at position 5 of the retrieved cases was 0.67 and at the top of the curve it was 0.96, both of which are very high. The mean average of precision (MAP) was 0.61 and the normalized discounted cumulative gain (NDCG) was 0.74 both of which confirmed the efficient performance of our model. All the metrics demonstrated the efficiency of our model. This methodology merits further research development to match clinical applications for designing RPDs. This paper is organized as follows. After the introduction and description of the basis for the paper, the evaluation and results are presented in Section 2. Section 3 provides a discussion of the methodology and results. Section 4 describes the details of the ontology, similarity algorithm, and application.

  1. Effect of different solutions on color stability of acrylic resin-based dentures

    Directory of Open Access Journals (Sweden)

    Marcelo Coelho Goiato

    2014-01-01

    Full Text Available The aim of this study was to evaluate the effect of thermocycling and immersion in mouthwash or beverage solutions on the color stability of four different acrylic resin-based dentures (Onda Cryl, OC; QC20, QC; Classico, CL; and Lucitone, LU. The factors evaluated were type of acrylic resin, immersion time, and solution (mouthwash or beverage. A total of 224 denture samples were fabricated. For each type of resin, eight samples were immersed in mouthwashes (Plax-Colgate, PC; Listerine, LI; and Oral-B, OB, beverages (coffee, CP; cola, C; and wine, W, and artificial saliva (AS; control. The color change (DE was evaluated before (baseline and after thermocycling (T1, and after immersion in solution for 1 h (T2, 3 h (T3, 24 h (T4, 48 h (T5, and 96 h (T6. The CIE Lab system was used to determine the color changes. The thermocycling test was performed for 5000 cycles. Data were submitted to three-way repeated-measures analysis of variance and Tukey's test (p < 0.05. When the samples were immersed in each mouthwash, all assessed factors, associated or not, significantly influenced the color change values, except there was no association between the mouthwash and acrylic resin. Similarly, when the samples were immersed in each beverage, all studied factors influenced the color change values. In general, regardless of the solution, LU exhibited the greatest DE values in the period from T1 to T5; and QC presented the greatest DE values at T6. Thus, thermocycling and immersion in the various solutions influenced the color stability of acrylic resins and QC showed the greatest color alteration.

  2. Effect of different solutions on color stability of acrylic resin-based dentures.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Nóbrega, Adhara Smith; dos Santos, Daniela Micheline; Andreotti, Agda Marobo; Moreno, Amália

    2014-01-01

    The aim of this study was to evaluate the effect of thermocycling and immersion in mouthwash or beverage solutions on the color stability of four different acrylic resin-based dentures (Onda Cryl, OC; QC20, QC; Classico, CL; and Lucitone, LU). The factors evaluated were type of acrylic resin, immersion time, and solution (mouthwash or beverage). A total of 224 denture samples were fabricated. For each type of resin, eight samples were immersed in mouthwashes (Plax-Colgate, PC; Listerine, LI; and Oral-B, OB), beverages (coffee, CP; cola, C; and wine, W), and artificial saliva (AS; control). The color change (DE) was evaluated before (baseline) and after thermocycling (T1), and after immersion in solution for 1 h (T2), 3 h (T3), 24 h (T4), 48 h (T5), and 96 h (T6). The CIE Lab system was used to determine the color changes. The thermocycling test was performed for 5000 cycles. Data were submitted to three-way repeated-measures analysis of variance and Tukey's test (p<0.05). When the samples were immersed in each mouthwash, all assessed factors, associated or not, significantly influenced the color change values, except there was no association between the mouthwash and acrylic resin. Similarly, when the samples were immersed in each beverage, all studied factors influenced the color change values. In general, regardless of the solution, LU exhibited the greatest DE values in the period from T1 to T5; and QC presented the greatest DE values at T6. Thus, thermocycling and immersion in the various solutions influenced the color stability of acrylic resins and QC showed the greatest color alteration.

  3. A comparative evaluation of effect on water sorption and solubility of a temporary soft denture liner material when stored either in distilled water, 5.25% sodium hypochlorite or artificial saliva: An in vitro study

    Directory of Open Access Journals (Sweden)

    Aditi Garg

    2016-01-01

    Full Text Available Introduction: Soft denture liners have a key role in modern removable prosthodontics since they restore health to inflamed and abused mucosa by redistribution of forces transmitted to the edentulous ridges. The most common problems encountered using soft denture liners are water sorption and solubility when in contact with saliva or storage media. These problems are associated with swelling, distortion, support of Candida albicans growth, and stresses at the liner/denture base interface that reduces the bond strength. Objective: To evaluate the water sorption and solubility of commercially available acrylic based self cure soft denture lining material (GC RELINE™ Tissue Conditioner after immersion in three different storage media (distilled water, Shellis artificial saliva, 5.25% sodium hypochlorite disinfectant solution at time interval of 4, 7, 11, and 15 days. Material and Methods: The study involved preparation of artificial saliva using Shellis formula. A total 45 standardized samples of the material (GC RELINE™ were prepared in disk form (15 mm in diameter and 2 mm in thickness. The study was divided into three groups with storage in Control (distilled water, Shellis artificial saliva, and 5.25% sodium hypochlorite. Samples were dried in a desiccator and weighed in the analytical balance to measure the initial weight (mg/cm2 of the disks (W1. The first groups (15 samples were placed in 30 ml distilled water (Group A at 37΀C, second group 30 ml of artificial saliva (Group B and third group in 5.25% sodium hypochlorite (Group C. Disks were removed from disinfectant after 5 min and placed in 30 ml distilled water. On days 4, 7, 11, and 15, all samples were removed from their containers and reweighed to measure the weight (mg/cm2 of the disks after sorption (W2. The solubility was measured by placing the disks back in the desiccator after each sorption cycle and drying them to constant weight in the desiccator. These values were weight

  4. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  5. Team-based learning in a preclinical removable denture prosthesis module in a United Arab Emirates dental school.

    Science.gov (United States)

    Haj-Ali, Reem; Al Quran, Firas

    2013-03-01

    The purpose of this article is to describe the implementation of a team-based learning (TBL) approach in a removable denture prosthesis (RDP) module and present the results of students' performance in individual and group TBL activities and exam scores, students' experience with TBL and end of course evaluations, and faculty feedback. Course material at the College of Dentistry, University of Sharjah, United Arab Emirates, was transformed into seven conventional lectures and seven TBL sessions. Each TBL session consisted of pre-assigned reading (self-directed learning), in-class individual and group readiness tests (accountability), team problem-solving of patient RDP cases, and faculty-led class discussion (knowledge application). The course was assessed through scores from TBL session activities and course examinations, student satisfaction survey, and faculty feedback. Course grades were found to be higher using the TBL method then the traditional lecture-based method. Student evaluation data and faculty response indicated strong support for TBL as it was implemented in the course. The faculty noted a higher level of student engagement with team learning than in conventional class lecturing. TBL is an active-learning instructional strategy for courses with high student-to-faculty ratios. This approach provides regular feedback and the opportunity for students to develop higher reasoning skills.

  6. A technique to stabilize record bases for Gothic arch tracings in patients with implant-retained complete dentures.

    Science.gov (United States)

    Raigrodski, A J; Sadan, A; Carruth, P L

    1998-12-01

    Clinicians have long expressed concern about the accuracy of the Gothic arch tracing for recording centric relation in edentulous patients. With the use of dental implants to assist in retaining complete dentures, the problem of inaccurate recordings, made for patients without natural teeth, can be significantly reduced. This article presents a technique that uses healing abutments to stabilize the record bases so that an accurate Gothic arch tracing can be made.

  7. The Anti-Adhesive Effect of Curcumin on Candida albicans Biofilms on Denture Materials

    Directory of Open Access Journals (Sweden)

    Gordon Ramage

    2017-04-01

    Full Text Available The use of natural compounds as an alternative source of antimicrobials has become a necessity given the growing concern over global antimicrobial resistance. Polyphenols, found in various edible plants, offers one potential solution to this. We aimed to investigate the possibility of using curcumin within the context of oral health as a way of inhibiting and preventing the harmful development of Candida albicans biofilms. We undertook a series of adsorption experiments with varying concentrations of curcumin, showing that 50 μg/ml could prevent adhesion. This effect could be further synergized by the curcumin pre-treatment of yeast cells to obtain significantly greater inhibition (>90%, p < 0.001. Investigation of the biological impact of curcumin showed that it preferentially affected immature morphological forms (yeast and germlings, and actively promoted aggregation of the cells. Transcriptional analyses showed that key adhesins were down-regulated (ALS1 and ALS3, whereas aggregation related genes (ALS5 and AAF1 were up-regulated. Collectively, these data demonstrated that curcumin elicits anti-adhesive effects and that induces transcription of genes integrally involved in the processes related to biofilm formation. Curcumin and associated polyphenols therefore have the capacity to be developed for use in oral healthcare to augment existing preventative strategies for candidal biofilms on the denture surface.

  8. Denture adhesives: a systematic review.

    Science.gov (United States)

    Papadiochou, Sofia; Emmanouil, Ioannis; Papadiochos, Ioannis

    2015-05-01

    Denture adhesives have been the objective of scientific research for over half a century. Although they are used by denture wearers worldwide, investigations of their effectiveness and biocompatibility have led to controversial conclusions. The purpose of this study was to review the literature data with regard to the effectiveness and biocompatibility of denture adhesives as well as the attitudes of both patients and dental professionals toward these materials. An electronic search of English peer-reviewed dental literature in the Medline database was conducted to evaluate the effectiveness and biocompatibility of denture adhesives. There was no limitation in publication year, so the search included all the available scientific evidence included in that particular database until March 2014. Specific inclusion criteria were used for the selection of the appropriate articles. A manual search of the citations of the obtained articles followed to extend the electronic search. A full text review was carried out for only 32 articles. Of the 32 articles, 21 examined the efficacy of denture adhesives in terms of retention and stability and masticatory performance, 6 evaluated the issue of the biocompatibility of denture adhesives, and 5 presented the attitudes of either professionals or patients toward these materials. The majority of clinical studies supported the fact that denture adhesives enhance the retention, stability, and masticatory performance of a removable prosthesis. In terms of biocompatibility, long-term in vivo studies to investigate potential harmful effects were lacking. Patients are satisfied with denture adhesives that meet their needs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. A study to evaluate the location and frequency of denture-related ulcerations and postinsertion adjustments in complete denture patients

    Directory of Open Access Journals (Sweden)

    Saurabh Jain

    2017-01-01

    Full Text Available Background and Aims: Removable complete denture is one of the most common treatment modalities for completely edentulous patients. After denture insertion, patient very often faces problems with the denture even after complete care is taken during fabrication procedure. Most common complaint is traumatic ulcers. The present study aimed to locate the most common areas of ulcerations due to complete dentures, how frequently they occur and how many times patient visits for adjustment after insertion of complete denture. Materials and Methods: Two hundred and twenty-one patients were selected and were delivered complete dentures. Dentures were fabricated for all the patients. Each step of denture fabrication was controlled and guided by a prosthodontist. After placement of dentures, patients were evaluated at every recall visit and their dentures were adjusted. All the details of each visit (area of ulceration and number of visits were recorded in a self-designed format. Descriptive statistical analysis was done using SPSS version 13 software. Chi-squared test was used to evaluate the correlation between mucosal injuries and postinsertion day and the relationship between lesions, patient age, and patient gender. Results: All the 221 patients required denture adjustment due to mucosal injuries. No significant difference was found between denture-related injuries between males and females. Injuries related to mandibular dentures were significantly higher than those related to maxillary dentures. In mandible, the most common area of mucosal injury is posterior one-third of alveololingual sulcus; while in maxilla, the most common area of mucosal injury is labial frenum. Conclusion: Postinsertion adjustments are an important aspect of rehabilitating patient with complete dentures. Most of the denture-related injuries were in limiting areas. Proper border molding techniques, accurate secondary impressions, and use of pressure indicating paste during

  10. [Comparison of adaptation and microstructure of titanium upper complete denture base fabricated by selecting laser melting and electron beam melting].

    Science.gov (United States)

    Ye, Y; Xiong, Y Y; Zhu, J R; Sun, J

    2017-06-09

    Objective: To fabricate Ti alloy frameworks for a maxillary complete denture with three-dimensional printing (3DP) technique, such as selective laser melting (SLM) and electron beam melting (EBM), and to evaluate the microstructure of these frameworks and their adaptation to the die stone models. Methods: Thirty pairs of edentulous casts were divided into 3 groups randomly and equally. In each group, one of the three techniques (SLM, EBM, conventional technique) was used to fabricate Ti alloy frameworks. The base-cast sets were transversally sectioned into 3 sections at the distal of canines, mesial of first molars, and the posterior palatal zone. The gap between the metal base and cast was measured in the 3 sections. Stereoscopic microscope was used to measure the gap. Three pieces of specimens of 5 mm diameter were fabricated with Ti alloy by SLM, EBM and the traditional casting technology (as mentioned above). Scanning electron microscope (SEM) was used to evaluate the differences of microstructure among these specimens. Results: The gaps between the metal base and cast were (99.4±17.0), (98.2±26.1), and (99.6± 16.1) μm in conventional method; (99.4 ± 22.8), (83.1 ± 19.3), and (103.3 ± 13.8) μm in SLM technique; (248.3±70.3), (279.1±71.9), and (189.1±31.6) μm in EBM technique. There was no statistical difference in the value of gaps between SLM Ti alloy and conventional method Ti alloy group ( P> 0.05). There was statistical difference among EBM Ti alloy, conventional method Ti alloy and SLM Ti alloy group ( Palloy showed more uniform and compact microstructure than the cast Ti alloy and EBM Ti alloy did. Conclusions: SLM technique showed initial feasibility to manufacture the dental base of complete denture. The mechanical properties and microstructure of the denture frameworks prepared by SLM indicate that these dentures are appropriate for clinical use. EBM technique is inadequate to make a complete denture now.

  11. Muscle activity and masticatory efficiency with bilateral extension base removable partial dentures with different cusp angles.

    Science.gov (United States)

    Al-Omiri, Mahmoud K

    2018-03-01

    Whether masticatory efficiency and electromyographic activity are influenced by type of artificial teeth and food is unclear. The purpose of this clinical study was to evaluate the influence of extension base removable partial dentures (RPDs) with different cusp angles: anatomic (33 degrees), semianatomic (20 degrees), and nonanatomic (0 degrees) teeth on masticatory efficiency and muscle activity during the mastication of test foods with different textures. Twelve participants with RPDs were selected to perform masticatory efficiency and electromyographic tests. Surface electromyograms (EMGs) were used to record the activities of the masseter and temporalis muscles during the mastication of different types of test foods. The maximal voltage and duration were measured on the integrated EMG signal in each muscle during food mastication, and the mean reading of both sides was then recorded. Analysis of variance and the Tukey post hoc test were used to perform statistical analyses (α=.05). The masticatory efficiency of RPDs with nonanatomic teeth was significantly inferior to that of RPDs with anatomic and semianatomic teeth (P.05). Also, muscle activity (according to EMG) with RPDs with NA teeth was significantly higher than that with anatomic and semianatomic teeth (P<.05). RPDs with NA teeth were associated with higher EMG muscle activity and reduced masticatory efficiency than anatomic or semianatomic teeth. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Effect of microwave cured acrylic resin on candidal growth in complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on candidal growth . Seven completely edentulous male patients with on history of denture wearing participated in this study. all the selected patients were re-habilitated by mucosa supported complete dentures .The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. one month resting period was allowed so as candidal count can reach to normal, then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique.

  13. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    NARCIS (Netherlands)

    Polyzois, G.L.; Baat, C. de

    2012-01-01

    OBJECTIVE: To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. BACKGROUND: There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. MATERIALS AND METHODS:

  14. Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

    Directory of Open Access Journals (Sweden)

    Vahideh Nazari

    2017-01-01

    Full Text Available Objectives: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS. The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs with excessive crown height, fabricated from three different materials.Materials and Methods: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr, and polyetheretherketone (PEEK (n=10. After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05.Results: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001. The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively.Conclusions: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions in the molar region with excessive CHS.Keywords: Dental Implants; Polyetheretherketone; Zirconium oxide; Dental Restoration Failure; Dental Porcelain

  15. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Energy Technology Data Exchange (ETDEWEB)

    Borba, Marcia; Bona, Alvaro Della, E-mail: marcia_borb@hotmail.com [Universidade de Passo Fundo (UPF), RS (Brazil). Fac. de Odontologia; Miranda Junior, Walter Gomes; Cesar, Paulo Francisco [Universidade de Sao Paulo (USP), SP (Brazil). Fac. de Odontologia. Dept. de Biomateriais e Bioquimica Oral; Griggs, Jason Allan [Department of Biomedical Materials Science, Dental School, University of Mississippi Medical Center - UMMC, Jackson, MS (United States)

    2013-09-15

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm² connector cross-sections using a LAVA® CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross sectional images. Five measuring points were selected, as follows: MG- marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 μm). OA had the highest median gap dimension (125 μm), followed by the AOT point (105 μm). CA and AW gap width values were statistically similar, 66 and 65 μm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations. (author)

  16. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    International Nuclear Information System (INIS)

    Borba, Marcia; Bona, Alvaro Della

    2013-01-01

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm² connector cross-sections using a LAVA® CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross sectional images. Five measuring points were selected, as follows: MG- marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 μm). OA had the highest median gap dimension (125 μm), followed by the AOT point (105 μm). CA and AW gap width values were statistically similar, 66 and 65 μm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations. (author)

  17. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Directory of Open Access Journals (Sweden)

    Marcia Borba

    2013-09-01

    Full Text Available The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs (Y-TZP - LAVA, 3M-ESPE, using a novel methodology based on micro-computed tomography (micro-CT technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05. There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm. OA had the highest median gap dimension (125 µm, followed by the AOT point (105 µm. CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.

  18. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment.

    Science.gov (United States)

    Kaur, Harsimran; Datta, Kusum

    2015-01-01

    To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA) were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P) and rest 80 to heat-cured resilient liner (Molloplast B). Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm) in the space provided by a spacer of 3 mm, thermocycled (5-55°C) for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student's t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B) increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  19. Evaluation of Team-Based Learning and Traditional Instruction in Teaching Removable Partial Denture Concepts.

    Science.gov (United States)

    Echeto, Luisa F; Sposetti, Venita; Childs, Gail; Aguilar, Maria L; Behar-Horenstein, Linda S; Rueda, Luis; Nimmo, Arthur

    2015-09-01

    The aim of this study was to evaluate the effectiveness of team-based learning (TBL) methodology on dental students' retention of knowledge regarding removable partial denture (RPD) treatment. The process of learning RPD treatment requires that students first acquire foundational knowledge and then use critical thinking skills to apply that knowledge to a variety of clinical situations. The traditional approach to teaching, characterized by a reliance on lectures, is not the most effective method for learning clinical applications. To address the limitations of that approach, the teaching methodology of the RPD preclinical course at the University of Florida was changed to TBL, which has been shown to motivate student learning and improve clinical performance. A written examination was constructed to compare the impact of TBL with that of traditional teaching regarding students' retention of knowledge and their ability to evaluate, diagnose, and treatment plan a partially edentulous patient with an RPD prosthesis. Students taught using traditional and TBL methods took the same examination. The response rate (those who completed the examination) for the class of 2013 (traditional method) was 94% (79 students of 84); for the class of 2014 (TBL method), it was 95% (78 students of 82). The results showed that students who learned RPD with TBL scored higher on the examination than those who learned RPD with traditional methods. Compared to the students taught with the traditional method, the TBL students' proportion of passing grades was statistically significantly higher (p=0.002), and 23.7% more TBL students passed the examination. The mean score for the TBL class (0.758) compared to the conventional class (0.700) was statistically significant with a large effect size, also demonstrating the practical significance of the findings. The results of the study suggest that TBL methodology is a promising approach to teaching RPD with successful outcomes.

  20. The Continuation Study of the Measurement of Residual Monomer from theDenture Base After Three Month Worn by Gas Chromatography on the Radiationand Non Radiation Worker

    International Nuclear Information System (INIS)

    Isyuniarto; Winoto

    2000-01-01

    Residual monomer measurement on the radiation and non radiation workerafter three month worn the denture has been done. The aim of the research isto investigated residual monomer concentration on after three month worn. Thedenture base material, made of resin acrylic, sometimes is cause mucosairritation in the mouth, and dental irritation or allergic reaction, becauseof residual monomer that left on the mouth cavity. In this research two groupwere needed there are the radiation and non radiation worker, the level ofthe residual monomer count by gas chromatography analysis. The result of thisresearch showed that the level of residual monomer of two group are same orthere have same level of the limit value. The measurement result is in therange of 0.1783 ± 0.011 mg/l to 0.1790 ± 0.004 mg/l. (author)

  1. Magnetic attachment for implant overdentures: influence of contact relationship with the denture base on stability and bending strain.

    Science.gov (United States)

    Yang, Tsung-Chieh; Maeda, Yoshinobu; Gonda, Tomoya; Wada, Masahiro

    2013-01-01

    This study evaluated how the contact height between the magnetic attachment and denture base influences stability and bending strain. An implant modified with strain gauges and a magnetic attachment mounted in an acrylic resin block were used to characterize systems with varying degrees or heights of contact with the abutment. Bending strain under lateral loading increased significantly as the contact height decreased. In the no contact and resilient contact groups, magnetic assemblies separated at reduced bending strain in all loading conditions. The contact height of the magnetic attachment influenced the stability and the amount of bending strain on the implant.

  2. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    OpenAIRE

    Saisadan, D.; Manimaran, P.; Meenapriya, P. K.

    2016-01-01

    Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, ...

  3. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture

    Directory of Open Access Journals (Sweden)

    D Saisadan

    2016-01-01

    Full Text Available Introduction: Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. Acrylics: These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composites: Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed Crowns: Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. Aims and Objectives: The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties – flexural strength, compressive strength, and color stability. Materials and Methods: The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan. Result: It was inferred from the study that no one material was superior in all three tested parameters.

  4. Efficacy of Denture Cleansers in Reducing Microbial Counts from Removable Partial Dentures: A Short-Term Clinical Evaluation

    OpenAIRE

    Lucena-Ferreira,Silvia Carneiro de; Cavalcanti,Indira Moraes Gomes; Cury,Altair Antoninha Del Bel

    2013-01-01

    This clinical study investigated if daily immersion in denture cleansers reduces microbial counts on removable partial denture's (RPD) biofilm. Twenty-five RPD wearer volunteers were selected and instructed to complement the hygiene of their dentures by immersing them in an enzymatic peroxide-based denture cleanser (Polident® 3 minute) once a day for 3 min for a period of 15 days. The biofilm was collected from RPD surfaces with a swab immediately before (baseline) and after the experimental ...

  5. In vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture.

    Science.gov (United States)

    Saisadan, D; Manimaran, P; Meenapriya, P K

    2016-10-01

    Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multiple-unit restorations. In general, their popularity is due to their low cost, acceptable esthetics, and versatility. Composite provisional materials use bis-acryl resin, a hydrophobic material that is similar to bis-GMA. Composites are available as auto-polymerized, dualpolymerized and visible light polymerized. Preformed provisional crowns or matrices usually consist of tooth-shaped shells of plastic, cellulose acetate or metal. They are commercially available in various tooth sizes and are usually selected for a particular tooth anatomy. They are commonly relined with acrylic resin to provide a more custom fit before cementation, but the plastic and metal crown shells can also be cemented directly onto prepared teeth. The aim of this study is to choose a material to serve as a better interim prosthesis and to compare three different properties - flexural strength, compressive strength, and color stability. The samples were made with three different provisional materials (Revotek LC, Protemp 4, TemSpan). It was inferred from the study that no one material was superior in all three tested parameters.

  6. Evaluation of efficacy of commercial denture cleansing agents to reduce the fungal biofilm activity from heat polymerized denture acrylic resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Mithilesh M Dhamande

    2012-01-01

    Full Text Available Aims: To compare and evaluate Candida removing effects of three most commonly available varieties of commercial denture cleansers from heat polymerized acrylic resins. To compare and evaluate Candida lytic effects of denture cleansers. To assess the effect of time on ability of denture cleansers in reducing Candidal biofilm. Materials and Methods: A specially designed metal mold was fabricated to obtain wax plates of uniform dimensions which were used to fabricate heat cure acrylic resin plates. A square-shaped window of dimension 15 mm and thickness of 1.5 mm was provided in metal mould to simulate thickness of denture base. All samples used in this study were prepared using this mould. Candida albicans colonies were then cultured on this acrylic resin plates by colonization assay. Yeast removing test for samples was performed using microscope and yeast lytic test was performed using photo colorimeter. Results: Denture cleanser D2 showed the highest Candida removing activity when compared with cleansers D1, D3, and control solution. Denture cleansers D2 showed increased yeast lytic ability when compared with denture cleansers D1, D3, and control solution. More time span shared a definite influence on yeast lytic ability of denture cleansers. Conclusions: The effect of cleansing agents on removal of colonized yeasts particularly fungal biofilm from acrylic resins was assessed for clinical implications. The observation indicated superior performance of cleanser D2 when compared with D1 and D3 even though they all belong to same chemical group of alkaline peroxide. The increased effectiveness may be due to presence of sodium lauryl sulphate in formula of D2.

  7. Video-based Learning Versus Traditional Method for Preclinical Course of Complete Denture Fabrication.

    Science.gov (United States)

    Fayaz, Amir; Mazahery, Azita; Hosseinzadeh, Mohammad; Yazdanpanah, Samane

    2015-03-01

    Advances in computer science and technology allow the instructors to use instructional multimedia programs to enhance the process of learning for dental students. The purpose of this study was to determine the effect of a new educational modality by using videotapes on the performance of dental students in preclinical course of complete denture fabrication. This quasi-experimental study was performed on 54 junior dental students in Shahid Beheshti University of Medical Sciences (SBMU). Twenty-five and 29 students were evaluated in two consecutive semesters as controls and cases, respectively for the same course. The two groups were matched in terms of "knowledge about complete denture fabrication" and "basic dental skills" using a written test and a practical exam, respectively. After the intervention, performance and clinical skills of students were assessed in 8 steps. Eventually, a post-test was carried out to find changes in knowledge and skills of students in this regard. In the two groups with the same baseline level of knowledge and skills, independent T-test showed that students in the test group had a significantly superior performance in primary impression taking (p= 0.001) and primary cast fabrication (p= 0.001). In terms of anterior teeth set up, students in the control group had a significantly better performance (p= 0.001). Instructional videotapes can aid in teaching fabrication of complete denture and are as effective as the traditional teaching system.

  8. Mechanical properties of materials used for temporary fixed dentures – in vitro study

    Directory of Open Access Journals (Sweden)

    Celej-Piszcz Elzbieta

    2017-06-01

    Full Text Available Objectives. The objective of the research was to define the mechanical properties of currently marketed temporary filling materials. Methods. Eight temporary filling materials: Boston, Dentalon, Protemp II, Revotek LC, Structure 2, Structure 3, UniFast LC, UniFast Trad were used to make 5 samples each of measurements 2 × 2 × 25 mm, in order to define the flexural strength, and 10 rings each of measurements 2 × 5 mm, in order to carry out the Vickers micro-hardness test. After preparation, the samples were stored in distilled water of temperature of 370°C, for 7 days. Subsequently, flexural strength and Vickers hardness testing was undertaken. Results. Composite temporary materials showed considerably better mechanical properties, both in flexural strength and in Vickers micro-hardness testing. Conclusions. the best mechanical properties, both in terms of flexural strength, as well as Vickers micro-hardness test can be observe among composite materials.

  9. Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles

    Directory of Open Access Journals (Sweden)

    Canan Bural

    2011-08-01

    Full Text Available OBJECTIVES: Residual methyl methacrylate (MMA may leach from the acrylic resin denture bases and have adverse effects on the oral mucosa. This in vitro study evaluated and correlated the effect of the leaching residual MMA concentrations ([MMA]r on in vitro cytotoxicity of L-929 fibroblasts. MATERIAL AND METHODS: A total of 144 heat-polymerized acrylic resin specimens were fabricated using 4 different polymerization cycles: (1 at 74ºC for 9 h, (2 at 74ºC for 9 h and terminal boiling (at 100ºC for 30 min, (3 at 74ºC for 9 h and terminal boiling for 3 h, (4 at 74ºC for 30 min and terminal boiling for 30 min. Specimens were eluted in a complete cell culture medium at 37ºC for 1, 2, 5 and 7 days. [MMA]r in eluates was measured using high-performance liquid chromatography. In vitro cytotoxicity of eluates on L-929 fibroblasts was evaluated by means of cell proliferation using a tetrazolium salt XTT (sodium 3´-[1-phenyl-aminocarbonyl-3,4-tetrazolium]bis(4-methoxy-6-nitrobenzenesulphonic acid assay. Differences in [MMA]r of eluates and cell proliferation values between polymerization cycles were statistically analyzed by Kruskal-Wallis, Friedman and Dunn's multiple comparison tests. The correlation between [MMA]r of eluates and cell proliferation was analyzed by Pearson's correlation test (p<0.05. RESULTS: [MMA]r was significantly (p<0.001 higher in eluates of specimens polymerized with cycle without terminal boiling after elution of 1 and 2 days. Cell proliferation values for all cycles were significantly (p<0.01 lower in eluates of 1 day than those of 2 days. The correlation between [MMA]r and cell proliferation values was negative after all elution periods, showing significance (p<0.05 for elution of 1 and 2 days. MMA continued to leach from acrylic resin throughout 7 days and leaching concentrations markedly reduced after elution of 1 and 2 days. CONCLUSION: Due to reduction of leaching residual MMA concentrations, use of terminal boiling in

  10. Flexible removable partial dentures: a basic overview.

    Science.gov (United States)

    Hill, Edward E; Rubel, Barry; Smith, John B

    2014-01-01

    For many years, flexible resin materials have been available for fabricating removable partial denture (RPD) prostheses. Using a nonrigid material for the major connector or other components of an RPD may be a consideration for certain patients. Except for the promotional literature that has been written for flexible resin dentures, there is very little information available in the dental literature concerning nonrigid RPDs. As a result, the decision to use this treatment option depends on the judgment and experience of the dentist and fabricating laboratory. This article summarizes clinically pertinent information about flexible, nonrigid partial dentures.

  11. Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

    Science.gov (United States)

    Ye, Ye; Jiao, Ting; Zhu, Jiarui; Sun, Jian

    2018-01-24

    The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P  0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.

  12. Dental health professional recommendation and consumer habits in denture cleansing.

    Science.gov (United States)

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    than 2 minutes. DHCP recommendations and denture wearer habits are diverse, with no consensus on the most appropriate denture cleaning methods. This reflects a lack of clear, systematic evidence upon which to base recommendations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Removable denture-related oral mucosal lesions: descriptive clinical study

    Directory of Open Access Journals (Sweden)

    Gökçen Akçiçek

    2017-05-01

    Full Text Available Objective: The aim of this study was to investigate whether there was a relationship between removable denture-related oral mucosal lesions and denture type, and demographic characteristics. Materials and Method: The age, sex, denture type, systemic condition and medication use, presence of denture-related oral mucosal lesions (DROML, their locations and patients’ awareness of above mentioned lesions were recorded for 199 patients. Pearson chi-square test was used to analyse the relationship between the DROML and denture type, and demographic characteristics of the patients. Results: Among the patients included to the study, 122 (61.3% were female and 77 (38.7% were male. Ninety-six patients (48.2% exhibited DROML, whereas 103 patients (51.8% had no DROML. No relationship was detected between DROML and age, and sex (p>0.05. The most commonly detected DROML was denture stomatitis (34.7%. Denture stomatitis was significantly more frequently seen in partial denture wearers (p<0.05, while epulis fissuratum and flabby ridge were statistically more frequent in complete denture wearers (p<0.001. Traumatic ulcer was more frequently found in mandibular complete denture wearers (p<0.05, while epulis fissuratum and flabby ridge were significantly more common in maxillary complete denture wearers (p<0.001. Among the patients with DROML, 57.3% stated that they were unaware of these lesions. Conclusion: In this study sample, the rate of DROML was high in patients wearing removable dentures (48.2%, and more than half of the patients with DROML were not aware of these lesions. Upon these findings, it is considered that removable denture wearers should follow the denture usage instructions and should be informed about the importance of periodic controls.

  14. Swallowed dentures: Two cases and a review

    Directory of Open Access Journals (Sweden)

    Mahir Gachabayov

    2015-12-01

    Conclusion: Fixed dentures can be accidentally ingested as well as removable dentures. Denture loosening leads to accidental denture ingestion. Patients with denture loosening should be recommended to visit dentist as soon as possible.

  15. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position.

    Science.gov (United States)

    Jensen, Charlotte; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2016-12-01

    To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Thirty subjects with a bilateral unbounded posterior saddle received 2 PM and 2M implants. A new RPD was placed. Implant support was provided 3 months later. Two PM implants supported the RPD. After 3 months the 2M implants were used or vice versa. Outcome measures included oral health related quality of life (OHIP-NL49), general health status (SF-36), contentment assessed on a Visual Analogue Scale (VAS) and the number of hours that the RPD was worn. Data were collected prior to treatment, 3 months after having functioned with a new RPD and after 3 and 6 months with implant support. Finally, patients expressed their preferred implant position. The general health status (SF-36) was not influenced. OHIP-NL49 values and mean wearing-time were statistical significantly more favorable for ISRPD's, regardless of the implant position. Per day, the ISRPD's were worn 2-3h more than the unsupported new RPD. Patients' expectations were met as the VAS-scores of anticipated and realized contentment did not reach a statistical significant level (p>0.05). VAS scores for ISRPD's with M implant support were higher than for PM implant support. Finally, 56.7% of subjects preferred the M implant support, 13.3% expressed no preference and 30% opted for PM implant support. Mandibular implant support favorably influences oral health related patient-based outcome measures in patients with a bilateral free-ending situation. The majority of patients prefer the implant support to be in the molar region. Patients with a bilateral free-ending situation in the mandible opposed by a maxillary denture benefit from implant support to their mandibular removable partial denture. Most patients prefer this support to be in the molar region. Copyright © 2016

  16. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles.

    Science.gov (United States)

    Nam, Ki-Young

    2014-06-01

    This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.

  17. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    Science.gov (United States)

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  18. The influence of heat treatments on several types of base-metal removable partial denture alloys.

    Science.gov (United States)

    Morris, H F; Asgar, K; Rowe, A P; Nasjleti, C E

    1979-04-01

    Four removable partial denture alloys, Vitallium (Co-Cr alloy), Dentillium P.D. (Fe-Cr alloy), Durallium L.G. (Co-Cr-Ni alloy), and Ticonium 100 (Ni-Cr alloy), were evaluated in the as-cast condition and after heat treatment for 15 minutes at 1,300 degrees, 1,600 degrees, 1,900 degrees, and 2,200 degrees F followed by quenching in water. The following properties were determined and compared for each alloy at each heat treatment condition: the yield strengths at 0.01%, 0.1%, and 0.2% offsets, the ultimate tensile strength, the percent elongation, the modulus of elasticity, and the Knoop microhardness. The results were statistically analyzed. Photomicrographs were examined for each alloy and test condition. The following conclusions were made: 1. The "highest values" were exhibited by the as-cast alloy. 2. Heat treatment of the partial denture alloys tested resulted in reductions in strength, while the elongations varied. This study demonstrates that, in practice, one should avoid (a) prolonged "heat-soaking" while soldering and (b) grinding or polishing of the casting until the alloy is "red hot". 3. Durallium L.G. was the least affected by the various heat treatment conditions. 4. Conventional reporting of the yield strength at 0.2% offset, the ultimate tensile strength, and percent elongation are not adequate to completely describe and compare the mechanical behavior of alloys. The reporting of the yield strength at 0.01% offset, in addition to the other reported properties, will provide a more complete description of the behavior of the dental alloys.

  19. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  20. Denture adhesives improve mastication in denture wearers.

    Science.gov (United States)

    Gonçalves, Thais Marques Simek Vega; Viu, Flavia Carvalho; Gonçalves, Leticia Machado; Garcia, Renata Cunha Matheus Rodrigues

    2014-01-01

    This clinical trial evaluated the influence of denture adhesive (DA) use on masticatory function in denture wearers according to their denture-bearing ridge status. Thirty edentulous subjects, wearing new well-fitting dentures, were classified as having either a normal or resorbed ridge. Mastication was evaluated in patients who completed chewing tests with and without two DA substances (cream or strips), which were randomly assigned. A chewing test with a sieve method analyzed masticatory performance. A kinesiographic device evaluated chewing cycle, and a visual analog scale measured masticatory ability. Data were submitted to Mauchly's sphericity test, and PROC MIXED procedures were conducted on repeated measures. Tukey-Kramer tests performed appropriate statistical comparisons (P ≤ .05). DA use increased masticatory performance and ability in patients with both ridge types (P mastication by shortening the chewing cycle and by enhancing chewing ability and performance.

  1. Factors influencing patients’ satisfaction with complete dentures: a qualitative study.

    OpenAIRE

    Silva, Jessica de Cassia Motta; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; dos Santos, Jarbas Francisco Fernandes; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; Marchini, Leonardo; College of Dentistry – University of Iowa – Iowa City – IA – USA.

    2014-01-01

    Objective: The treatment most used worldwide for edentulism is conventional complete dentures, and the most important factor for the success of denture treatment seems to be patient satisfaction. The present study aims to use a qualitative approach to investigate factors that were previously associated with patient satisfaction with dentures by quantitative techniques (correlational studies). Material and methods: Twenty patients (12 women and 8 men, age 59-87) participated in open and semi-s...

  2. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    Science.gov (United States)

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from

  3. Influence of the mechanical properties of resilient denture liners on the retention of overdenture attachments.

    Science.gov (United States)

    Kubo, Keitaro; Koike, Takashi; Ueda, Takayuki; Sakurai, Kaoru

    2018-03-15

    Information is lacking about the selection criteria for silicone resilient denture liners applied as a matrix material for attachments on overdentures. The purpose of this in vitro study was to investigate the mechanical properties of silicone resilient denture liners and their influence on the initial retention force of overdenture attachments and the reduction in retention force over time. Nine types of silicone resilient denture liner were injected and fixed to the matrix section of an experimental denture base. They were then fitted to an epoxy resin model that simulated the residual ridge with a patrix ball attachment (n=10). The retention force of the denture was measured with a digital force gauge, and the maximum force of traction (N) was regarded as the initial retention force. The retention force reduction (N) after repeated insertion and removal (n=5) was calculated by subtracting the retention force after 3348 cycles (3-year simulated insertion and removal) from the initial retention force. The intaglio of the matrix was observed with a scanning electron microscope (SEM) before and after the 3348 cycles. Four mechanical properties (hardness, strain-in-compression, tensile strength, and arithmetic mean roughness) of the resilient denture liners were measured. One-way ANOVA of the initial retention force of each lining material was performed, followed by the Scheffe test (α=.05). Pearson correlation analysis was used (α=.05) to analyze correlations of the initial retention force with the retention force reduction after insertion and removal and the mechanical properties of each material. Multiple regression analysis with the stepwise method extracted the initial retention force and the retention force reduction as dependent variables, and the resilient denture liner mechanical properties as explanatory variables (α=.05). The initial retention force of the resilient denture liners was 1.3 to 5.4 N. Multiple comparisons showed significant differences in

  4. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  5. The Effect of Aloe vera Extract on Adherence of Candida albicans and Other Properties of Heat Cure Denture Soft Lining Material

    Directory of Open Access Journals (Sweden)

    Aseel Riyadh Abdulwahhab

    2018-03-01

    Full Text Available Objective: One of the serious drawbacks of denture soft lining materials is colonization by Candida albicans that might eventually leads to denture stomatitis. This can be treated either systemically or locally. With the recent increase interest in medicinal plants, this study aimed to evaluate the effect of Aloe vera powder incorporated with heat cure acrylic soft-liner powder on the adherence of Candida albicans, shear bond strength and tear strength. Methods: According to the results of pilot study, two percentages (3% and 10% of aloe vera powder was used. Candida adherence test, shear bond strength and tear strength tests were performed, also the long-term effect was evaluated after 2 and 4 weeks incubation in artificial saliva. All data was analyzed using SPSS software (version 24. Descriptive and inferential statistics, ANOVA test with post-hoc analysis was applied. Results: The results indicated that both concentrations of aloe vera showed a statistically highly significant decrease in Candida albicans cell count in comparison to control group, also a significant increase in shear bond strength and non-significant difference in tear strength of soft liner for the experimental groups. After 2 and 4 weeks incubation in artificial saliva, all experimental groups showed a statistically significant decrease in Candida albicans cell count and a statistically significant increase in shear bond strength and tear strength test. Conclusion: Incorporation of aloe vera powder with heat cure acrylic soft-liner powder helps to add an anti-candidal property to the soft liner, also this addition results in improvement in shear bond strength and tear strength.

  6. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study

    Directory of Open Access Journals (Sweden)

    Sumanth Babu

    2016-01-01

    Full Text Available Aim: The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Materials and Methods: Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA, which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results: Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05 and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05 movement in buccal direction during all stages of denture processing. Conclusion: Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  7. Liquid supported denture-management of flabby ridges

    Directory of Open Access Journals (Sweden)

    Pranav V Mody

    2012-01-01

    Full Text Available The ideal properties of a denture are adequate rigidity on polished surface to bear masticatory forces and at the same time, flexibility and softness on the tissue surface for proper and even distribution of masticatory forces. The problem with conventional denture is rigidity of tissue surface; leads to uneven distribution of load. This drawback even worsens in the case of flabby, atrophic and unemployed ridges with excessive bone resorption.The liquid supported denture allows continued adaptation and eliminates the disadvantages of denture designs based on the application of temporary tissue conditioners or soft liners.

  8. Creep and stress relaxation behavior of two soft denture liners.

    Science.gov (United States)

    Salloum, Alaa'a M

    2014-03-01

    Numerous investigators stated the indications of soft denture lining materials; but no one determined the indications of these materials according to their chemical structure. The purpose of this investigation was to evaluate the viscoelastic properties of acrylic and silicon lining materials. This study investigated and compared viscoelastic properties of two resilient denture lining materials. Tested materials were laboratory processed; one of them was silicone-based liner product (Molloplast-B), and the other was plasticized acrylic resin (Vertex™ Soft). Twenty cylindrical specimens (10-20 mm in length, 11.55 mm in diameter) were fabricated in an aluminum mold from each material for creep and stress relaxation testing (the study of viscoelastic properties). Tests were performed by using the universal testing machine DY-34. Collected data were analyzed with t test statistics for statistically significant differences at the 95 % confidence level. There was a clear difference in creep and stress relaxation behavior between acrylic and silicone liners. Statistical study of Young's moduli illustrated that Vertex™ Soft was softer than Molloplast-B. On the other hand, the results explained that the recovery of silicone material was better than of acrylic one. The creep test revealed that the plasticized acrylic resin lining material exhibited considerable creep, whereas silicone-based liner exhibited elastic behavior. Besides, the stress relaxation test showed that relaxation of the plasticized acrylic resin material was bigger than of the silicone-based liner.

  9. Denture quality has a minimal effect on health-related quality of life in patients with removable dentures.

    Science.gov (United States)

    Inoue, M; John, M T; Tsukasaki, H; Furuyama, C; Baba, K

    2011-11-01

    The present study examined the association of denture quality and health-related quality of life (HRQoL) in patients with removable dentures. In a study of 171 consecutive patients with removable partial dentures or complete dentures (mean age: 68·0 ± 9·3 years) at a university-based prosthodontic clinic, dentists rated two aspects of denture quality (stability and aesthetics) using a 100-mm visual analog scale (VAS). HRQoL was evaluated using the mental and physical component summary (MCS and PCS) scores of the Medical Outcomes Study Short-Form 36-Item Health Survey (SF-36). Oral health-related quality of life (OHRQoL) was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J). The associations among denture quality, OHRQoL, and HRQoL were examined by linear regression models. Bivariable linear regression analyses revealed that denture stability was significantly associated with the SF-36 MCS [regression coefficient = 0·52 for a 10-unit increase in denture stability on a 0-100 VAS, 95% confidence interval (CI): 0·03-1·00, P = 0·04], but not with the PCS (0·11, 95% CI: -0·49 to 0·70). Denture aesthetics was not related to the PCS or the MCS (0·22, 95% CI: -0·44 to 0·88 or 0·07, 95%CI: -0·47 to 0·62). When OHIP-J was added to the regression model, this variable was substantially and significantly associated with the MCS and PCS summary scores; in addition, the regression coefficient for denture quality decreased in magnitude and was statistically nonsignificant in all analyses. The quality of removable dentures had a minimal effect on HRQoL in patients with removable dentures, and this association was mediated by OHRQoL. © 2011 Blackwell Publishing Ltd.

  10. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report

    OpenAIRE

    Hazari, Puja; Mishra, Sunil Kumar

    2015-01-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section ov...

  11. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    Science.gov (United States)

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  12. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements

    Directory of Open Access Journals (Sweden)

    Moises NOGUEIRA

    Full Text Available Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups (n=10 for upper and lower arches according to polymerization method: 1 conventional one-stage - a wax trial base was made, teeth were arranged and polymerized; 2 two-stage method - the base was waxed and first polymerized. With the denture base polymerized, the teeth were arranged and then, performed the final polymerization. Teeth movements were evaluated in the distances between incisive (I-I, pre-molars (P-P, molars (M-M, left incisor to left molar (LI-LM and right incisor to right molar (RI-RM. For the adaptation analysis, dentures were cut in three different positions: (A distal face of canines, (B mesial face of the first molars, and (C distal face of second molars. Result Denture bases have shown a significant better adaptation when polymerized in the one-stage procedure for both the upper (p=0.000 and the lower (p=0.000 arches, with region A presenting significant better adaptation than region C. In the upper arch, significant reduction in the distance between I-I was observed in the one-stage technique, while the two-stage technique promoted significant reduction in the RI-RM distance. In the lower arch, one-stage technique promoted significant reduction in the distance for RI-RM and two-stage promoted significant reduction in the LI-LM distance. Conclusion Conventional one-stage method presented the better results for denture adaptation. Both fabrication methods presented some alteration in teeth movements.

  13. Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures.

    Science.gov (United States)

    Arslan, Mustafa; Murat, Sema; Alp, Gulce; Zaimoglu, Ali

    2018-01-01

    ] had significantly higher CA, and consequently higher hydrophobicity when compared to CAD/CAM polymers [M] and [P] (P 0.05). The FS and hydrophobicity of the CAD/CAM PMMA-based polymers were higher than the conventional heat-polymerized PMMA, whereas the CAD/CAM PMMA-based polymers had similar Ra values to the conventional PMMA. Thermocycling had a significant effect on FS and hydrophobicity except for the Ra of denture base materials.

  14. The effectiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures

    Directory of Open Access Journals (Sweden)

    Patrícia Costa Cruz

    2011-12-01

    Full Text Available Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth. OBJECTIVE: This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets, mechanical (ultrasonic and combined (association of the effervescent and ultrasonic methods. MATERIAL AND METHODS: Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20: (1 Brushing with water (Control; (2 Effervescent tablets (Corega Tabs; (3 Ultrasonic device (Ultrasonic Cleaner, model 2840 D; (4 Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm quantified (Image Tool 2.02. The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture. RESULTS: The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; P<0.001, the mean ranks for the treatments and results for Dunn multiple comparison test were: Control (60.9; Chemical (37.2; Mechanical (35.2 and Combined (29.1. CONCLUSION: The experimental methods were equally effective regarding the ability to remove biofilm and were superior to the control method (brushing with water. Immersion in alkaline peroxide and ultrasonic vibration can be used as auxiliary agents

  15. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position

    NARCIS (Netherlands)

    Jensen, Charlotte; Raghoebar, Gerry M.; Kerdijk, Wouter; Meijer, Henny J. A.; Cune, Marco S.

    2016-01-01

    Objectives: To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Methods: Thirty subjects with a bilateral

  16. [Oral mucosa reaction in patients adapting to removable dentures].

    Science.gov (United States)

    Iordanishvili, A K; Soldatova, L N; Pihur, O L; Mihajlova, E S; Peremyshlenko, A S; Soldatov, V S

    Oral mucosa reaction of prosthetic bed to the removable acrylic dentures was evaluated in 43 patients (12 male and 31 female) aged 56-69 years with partial and full teeth loss in one or both jaws. Patients of the first (control) group (17 patients) were not using additional tools improving fixation of the removable dentures during adaptation period, while patients of the second (main) group (26 patients) used Corega cream for dentures fixation for 30 days follow-up. Oral mucosa assessment was carried out on 3-4 and 28-30 day of dentures use by 3 end points: pain syndrome, moisture level, inflammation of a prosthetic bed. The results proved Corega cream to improve prosthetic bed mucosa condition reducing inflammatory response to polymeric materials of removable dentures basis.

  17. Clinical evaluation of isolated abutment teeth in removable partial dentures

    Directory of Open Access Journals (Sweden)

    Zarrati S

    2011-02-01

    Full Text Available "nBackground and Aims: Nowadays, removable partial dentures are applied to patients who are not able to use dental implants or fixed prosthesis. Although based on the studies the users of removable partial dentures are in the risk of plaque accumulation and unacceptable changes such as gingivitis, periodontitis and mobility in abutment tooth. It is not clear whether the negative effects of removable partial dentures are more on the isolated teeth which are a kind of abutment adjacent to endentulous area in both sides. The purpose of this study was to investigate the clinical condition of isolated abutment teeth without splinting in comparison to control abutment from the aspects of B.O.P (bleeding on probing, mobility, pocket depth and gingivitis."nMaterials and Methods: In this cross-sectional study, the prepared questionnaires were filled out by 50 patients who received removable partial dentures in department of removable prosthodontics of dental school of Tehran University of Medical Sciences. The patients had isolated abutment tooth and did not have any systemic disease. The obtained data were analyzed. Using Wilcoxon, exact Fisher and Kruskal-Wallis test."nResults: B.O.P (P=0.004, pocket depth (P=0.035, and mobility (P<0.001 in isolated abutments were more than those in control abutments, but there were not significant differences in the degree of caries (P=0.083 and gingivitis (P=0.07."nConclusion: This study showed that clinical condition of isolated abutments is worse than that of control abutments. More attention should be paid to healthiness of isolated teeth without splinting and periodic follow ups should be done in these cases.

  18. Unilateral removable partial dentures.

    Science.gov (United States)

    Goodall, W A; Greer, A C; Martin, N

    2017-01-27

    Removable partial dentures (RPDs) are widely used to replace missing teeth in order to restore both function and aesthetics for the partially dentate patient. Conventional RPD design is frequently bilateral and consists of a major connector that bridges both sides of the arch. Some patients cannot and will not tolerate such an extensive appliance. For these patients, bridgework may not be a predictable option and it is not always possible to provide implant-retained restorations. This article presents unilateral RPDs as a potential treatment modality for such patients and explores indications and contraindications for their use, including factors relating to patient history, clinical presentation and patient wishes. Through case examples, design, material and fabrication considerations will be discussed. While their use is not widespread, there are a number of patients who benefit from the provision of unilateral RPDs. They are a useful treatment to have in the clinician's armamentarium, but a highly-skilled dental team and a specific patient presentation is required in order for them to be a reasonable and predictable prosthetic option.

  19. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study.

    Science.gov (United States)

    Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi

    2017-01-01

    The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  20. Effect of Microwave Cured Acrylic Resin on Candidal Growth in Complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on Candidal growth. Seven completely edentulous male patients with no history of denture wearing participated in this study. All the selected patients were re-habilitated by mucosa supported complete dentures. The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. One month resting period was allowed so as Candidal count can reach to normal. Then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique. In the oral rinse technique, the patients were instructed to rinse their mouths with 10 mL of sterile phosphate buffered saline for 60 seconds. The rinse was then expectorated into a universal container and immediately transported to the laboratory for concentration by centrifugation, then cultured on sabouraud's dextrose agar plates which were incubated at 37 degree C for 48 hours. Microscopic examination and germ tube test were carried out for laboratory investigations. In addition, the morphological features of the isolated Candida from the samples tested in this study, were investigated using the scanning electron microscope(SEM)

  1. Trial of an experimental castor oil solution for cleaning dentures.

    Science.gov (United States)

    Andrade, Ingrid Machado de; Andrade, Kelly Machado de; Pisani, Marina Xavier; Silva-Lovato, Cláudia Helena; de Souza, Raphael Freitas; Paranhos, Helena de Freitas Oliveira

    2014-01-01

    Denture hygiene is essential because denture biofilm is involved in oral infections and systemic diseases. Although there are chemical agents available on the market, none of them have ideal properties and research on such products is still necessary. The aim of this study was to evaluate the efficacy of a castor bean (Ricinus communis)-based solution for removing denture biofilm, compared to two traditional products (sodium hypochlorite and alkaline peroxide). Fifty maxillary complete denture wearers were instructed to brush their dentures after meals and to immerse their dentures once a day in the following solutions: Saline (20 min; control), Polident alkaline peroxide (3 min), NaOCl (20 min) and 2% castor oil solution (20 min). Participants used each solution for a period of 7 consecutive days, according to a random sequence. After each period, the internal surfaces of maxillary complete dentures were stained with a disclosing solution (1% neutral red), photographed and the disclosed biofilm was quantified with the aid of specific software. The influence of treatments on results was verified by the Friedman test (α=0.05). Tested solutions presented significant difference (Fr=51.67; pcastor oil presented intermediate results (median: 1.0% and 1.5%, respectively). It can be concluded that the castor oil solution tested in this study was comparable to alkaline peroxide in terms of efficiency in denture biofilm removal.

  2. [Gerontoprosthesis. Concept of rebuilding old complete dentures].

    Science.gov (United States)

    Marxkors, R; Mayer, K

    1990-04-01

    If aged patients who have been wearing their full dentures without complications so far, need further prothetic treatment, the dentist must not replace the old denture by a completely new one. It is better to rebuild it step by step. This demand is based on the following theses: --Nobody but the patient himself is able to perform functional movements. --Unless bite and occlusion are correct, patients are not able to perform accurate functional movements. --When bite and occlusion have been checked and, if necessary, improved, bases and alveolar ridges must be congruent.

  3. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    Dual Component Removable Partial Denture (DuCo RPD) is composed of a double base; lower and upper. The lower base, where the artificial teeth are attached, acts as a support and is in contact with the alveolar ridges and oral mucosa. Clasps are designed on the upper base, which acts towards the retention and ...

  4. Rresence of different Candida species at denture wearers with type 2 diabetes and clinically healthy oral mucosa: Pilot study

    OpenAIRE

    Matić-Petrović, Sanja; Barać, Milena; Kuzmanović-Pfićer, Jovana; Radunović, Milena; Jotić, Aleksandra; Pucar, Ana

    2018-01-01

    Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS) and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental...

  5. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  6. Functional Impressions in Complete Denture and Overdenture Treatment

    Directory of Open Access Journals (Sweden)

    Hrvoje Kršek

    2015-01-01

    Full Text Available Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions.

  7. Studies on the effects of titanate and silane coupling agents on the performance of poly (methyl methacrylate)/barium titanate denture base nanocomposites.

    Science.gov (United States)

    Elshereksi, Nidal W; Ghazali, Mariyam J; Muchtar, Andanastuti; Azhari, Che H

    2017-01-01

    This study aimed to fabricate and characterise silanated and titanated nanobarium titanate (NBT) filled poly(methyl methacrylate) (PMMA) denture base composites and to evaluate the behaviour of a titanate coupling agent (TCA) as an alternative coupling agent to silane. The effect of filler surface modification on fracture toughness was also studied. Silanated, titanated and pure NBT at 5% were incorporated in PMMA matrix. Neat PMMA matrix served as a control. NBT was sonicated in MMA prior to mixing with the PMMA. Curing was carried out using a water bath at 75°C for 1.5h and then at 100°C for 30min. NBT was characterised via Fourier transform-infrared spectroscopy (FTIR), Transmission Electron Microscopy (TEM) and Brunauer-Emmett-Teller (BET) analysis before and after surface modification. The porosity and fracture toughness of the PMMA nanocomposites (n=6, for each formulation and test) were also evaluated. NBT was successfully functionalised by the coupling agents. The TCA exhibited the lowest percentage of porosity (0.09%), whereas silane revealed 0.53% porosity. Statistically significant differences in fracture toughness were observed among the fracture toughness values of the tested samples (pPMMA composites. Thus, TCA seemed to be more effective than silane. Minimising the porosity level could have the potential to reduce fungus growth on denture base resin to be hygienically accepTable Such enhancements obtained with Ti-NBT could lead to promotion of the composites' longevity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

    Science.gov (United States)

    Yoo, Jin Suk; Kwon, Kung-Rock; Noh, Kwantae; Lee, Hyeonjong; Paek, Janghyun

    2017-06-01

    The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

  9. Oral mucosal lesions in denture wearers.

    Science.gov (United States)

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  10. Flexural Strength of Acrylic Resin Denture Bases Processed by Two Different Methods

    Directory of Open Access Journals (Sweden)

    Jafar Gharechahi

    2014-09-01

    Full Text Available Background and aims. The aim of this study was to compare flexural strength of specimens processed by conventional and injection-molding techniques. Materials and methods. Conventional pressure-packed PMMA was used for conventional pressure-packed and injection-molded PMMA was used for injection-molding techniques. After processing, 15 specimens were stored in distilled water at room temperature until measured. Three-point flexural strength test was carried out. Statistical analysis was carried out by SPSS using t-test. Statistical significance was defined at P<0.05. Results. Flexural strength of injection-polymerized acrylic resin specimens was higher than that of theconventional method (P=0.006. This difference was statistically significant (P=0.006. Conclusion. Within the limitations of this study, flexural strength of acrylic resin specimens was influenced by the mold-ing technique.

  11. Complication rates and patient satisfaction with removable dentures

    Science.gov (United States)

    Bilhan, Hakan; Erdogan, Ozge; Ergin, Selen; Celik, Melahat; Ates, Gokcen

    2012-01-01

    PURPOSE The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of Pdentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations (Pdentures with wrong centric relations caused need for addition of artificial teeth. PMID:22737317

  12. Patient’s Satisfaction with Removable Partial Dentures: A Retrospective Case Series

    Science.gov (United States)

    Shala, Kujtim Sh.; Dula, Linda J.; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient’s satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. Material and Methods: A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. Result: The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient’s satisfaction with RPD with or without attachment. Conclusion: Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics. PMID:28077970

  13. "Nature cures:" An alternative herbal formulation as a denture cleanser.

    Science.gov (United States)

    Sushma, R; Sathe, Tanuja Tanaji; Farias, Anand; Sanyal, Pronob Kumar; Kiran, Shashi

    2017-01-01

    Candida albicans is one of the microorganisms which harbor the oral cavity, especially in elderly. However, the incidence of existence of this increases in patients using removable dental prosthesis. There is therefore a need to test the anticandidal efficacy of these cost-effective, easily available products to be used as routine denture cleansers. (1) To evaluate antifungal properties of triphala churna on the heat cure denture base material. (2) To evaluate the antifungal effect of chlorhexidine gluconate on the heat cure denture base material. (3) To compare the antifungal effect of triphala churna and chlorhexidine gluconate with a control. (4) To evaluate which among triphala churna and chlorhexidine gluconate has a better antifungal property on the heat cure denture base material. Study population consisted of sixty dentures wearers from those attending the Outpatient Department of Prosthodontics of the School of Dentistry, Krishna Institute of Medical Sciences Deemed University, Karad. Swabs were collected from the dentures before and after the use of triphala and chlorhexidine. The swabs were cultured on Sabouraud dextrose agar and the total Candida counts were determined. Triphala as an antifungal is shown to have more efficacy than the conventional chlorhexidine mouthwash. Résumé Arrière-plan: Candida albicans est l'un des micro-organismes qui abritent la cavité buccale surtout chez les personnes âgées. Cependant, l'incidence de l'existence de cette augmentation chez les patients utilisant des prothèses dentaires amovibles. Il est donc nécessaire de tester l'efficacité anticancédique de ces produits rentables et faciles à utiliser pour être utilisés comme nettoyants de routine pour prothèses dentaires. Buts et Objectifs: (1) Évaluer les propriétés antifongiques de Triphala churna sur le matériau de base de la prothèse thermo-durcissable. (2) Évaluer l'effet antifongique du gluconate de chlorhexidine sur le matériau de base de la

  14. The Effect of Two Types of Denture Adhesive on the Satisfaction Parameters of Complete Denture Wearers

    Directory of Open Access Journals (Sweden)

    Farzin M

    2017-09-01

    Full Text Available Statement of Problem: Patient satisfaction is highly influenced by the retention of the denture. In some instances using denture adhesives may help the patient to achieve this goal. Objectives: The purpose of this study was to evaluate the participants’ ’opinion concerning the effectiveness of two types of denture adhesives having the same composition (Fixative-powder, Protefix-cream. Materials and Methods: Forty healthy patients (25 Males and 15 Fe-males who visited the Department of Prosthodontics of Shiraz Dentistry School were selected. The oral cavity was examined and patients with oral ulcers, history of allergic reaction, severe xerostomia, red, white and/or red and white lesions were excluded. The subjects were instructed to receive a sequence of treatment protocols. All patients applied Fixative-powder on the dentures for seven days. The Participants were asked to fill a question-naire to include their opinion regarding the strength, biocompatibility, convenience and masticatory ability of the adhesive. On the next seven days, the patients were asked not to use the adhesives and they completed the same questionnaire again. Finally, all participants were asked to apply Protefix-cream on their dentures for a week followed by no cream applica-tion for another 7 days. These patients answered the same questionnaire and data were collected and analyzed using paired-samples t-test and Chi-square test. Result: Denture adhesives significantly improved the overall satisfaction level of the patients (p =0.01. When testing the fixative powder, the satis-faction score of the participants during the first week (powder application and the 2nd weak (no application was 19.95±3.76 and 26.2±2.82, respec-tively. The overall satisfaction rate of the patients using the Protefix adhe-sive was 19.35±5.48 in the third week (adhesive application and 25.85± 4.35 in the fourth week (no application. Conclusions: The study clarified that applying denture

  15. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  16. Cell cycle indicators of buccal epithelial cells in the treatment of different types of removable plate partial dentures

    Directory of Open Access Journals (Sweden)

    E. V. Beliaiev

    2018-02-01

    Full Text Available The purpose of the work. To investigate nuclear DNA and buccal epithelial cells proliferative activity in patients with dental defects, who use removable partial dentures plates made of acrylic or thermoplastic. Materials and Methods. The study of buccal epithelial cell cycle parameters was carried out in 70 people. Among them 23 patients were treated with acrylic dentures prostheses, 23 patients – with thermoplastic-based prostheses. The comparison group consisted of 24 clinically healthy persons without defects in the dentition. DNA content in human buccal epithelial cells nuclei was determined by flow cytometry. Results. The obtained indicators of buccal epithelial cell cycle of the control group indicate a high intensity of cell self-renewal in the normal range. It is suggested by a significant percentage of events occurring within the Sub-G1 range that characterizes apoptosis, as well as the fact that more than half of the cells were in the range of S + G2/M. It has been revealed by flow cytometry that the percentage of apoptosis in cells was higher in patients using acrylic dentures base plastic, showed initial signs of keratinization that was confirmed by increase in cells in the range of Sub-G1 and by their decrease in the range of S-G2/M. It has been established in the study of buccal epithelium cell cycle indicators in the dentures bases thermoplastic application that these prostheses did not affect the proliferative activity of buccal epithelial cells compared to the group using acrylic dentures bases with prolonged use. This is evident in almost the same number of cellular events ranging Sub-G1, so apoptosis in the thermoplastic dentures bases application corresponded to the control group indicators both in the early period and over a year of use. Conclusions. The direct negative effect of prostheses with acrylic bases on the complex mechanism of the oral cavity mucous membrane functioning has been revealed. Absence of dentures

  17. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  18. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components.

    Science.gov (United States)

    Jiao, T; Chang, T; Caputo, A A

    2009-03-01

    To photoelastically examine load transfer by unilateral distal extension removable partial dentures with supporting and retentive components made of the lower stiffness polyacetal resins. A mandibular photoelastic model, with edentulous space distal to the right second premolar and missing the left first molar, was constructed to determine the load transmission characteristics of a unilateral distal extension base removable partial denture. Individual simulants were used for tooth structure, periodontal ligament, and alveolar bone. Three designs were fabricated: a major connector and clasps made from polyacetal resin, a metal framework as the major connector with polyacetal resin clasp and denture base, and a traditional metal framework I-bar removable partial denture. Simulated posterior bilateral and unilateral occlusal loads were applied to the removable partial dentures. Under bilateral and left side unilateral loading, the highest stress was observed adjacent to the left side posterior teeth with the polyacetal removable partial denture. The lowest stress was seen with the traditional metal framework. Unilateral loads on the right edentulous region produced similar distributed stress under the denture base with all three designs but a somewhat higher intensity with the polyacetal framework. The polyacetal resin removable partial denture concentrated the highest stresses to the abutment and the bone. The traditional metal framework I-bar removable partial denture most equitably distributed force. The hybrid design that combined a metal framework and polyacetal clasp and denture base may be a viable alternative when aesthetics are of primary concern.

  19. [Removable partial dentures. Oral functions and types

    OpenAIRE

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combinatio...

  20. Clinical evaluation of failures in removable partial dentures.

    Science.gov (United States)

    Jorge, Janaina H; Quishida, Cristiane C C; Vergani, Carlos E; Machado, Ana L; Pavarina, Ana C; Giampaolo, Eunice T

    2012-01-01

    The aim of this clinical study was to evaluate the effects of removable partial dentures on the support tissues and changes occurring in lower tooth-supported and bilateral distal-extension dentures, 5 years after placement. The study involved analysis of a total of 53 patients who received prosthetic treatment for removable partial dentures. The patients were divided into two groups. In group 1, the patients had a completely edentulous maxilla and an edentulous area with natural teeth remaining in both the anterior and posterior regions. In group 2, the patients had a completely edentulous maxilla and partially edentulous mandible with preserved anterior teeth. Tooth mobility, prevalence of caries, fracture of the abutment teeth, fracture and/or deformation of the removable partial denture components and stability of the denture base were evaluated. The use of a removable partial denture increased tooth mobility, reduced the prevalence of caries, and did not cause loss or fracture of the abutments or damage to their components, when compared with the baseline. It was concluded that there was no difference between the groups as evaluated in terms of tooth mobility, prevalence of caries, loss and fracture of the abutments or damage to the components of the removable partial denture.

  1. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  2. LDEF materials data bases

    Science.gov (United States)

    Funk, Joan G.; Strickland, John W.; Davis, John M.

    1993-01-01

    The Long Duration Exposure Facility (LDEF) and the accompanying experiments were composed of and contained a wide variety of materials representing the largest collection of materials flown in low Earth orbit (LEO) and retrieved for ground based analysis to date. The results and implications of the mechanical, thermal, optical, and electrical data from these materials are the foundation on which future LEO space missions will be built. The LDEF Materials Special Investigation Group (MSIG) has been charged with establishing and developing data bases to document these materials and their performance to assure not only that the data are archived for future generations but also that the data are available to the spacecraft user community in an easily accessed, user-friendly form. This paper discusses the format and content of the three data bases developed or being developed to accomplish this task. The hardware and software requirements for each of these three data bases are discussed along with current availability of the data bases. This paper also serves as a user's guide to the MAPTIS LDEF Materials Data Base.

  3. Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study.

    Science.gov (United States)

    Rao, Duggineni Chalapathi; Kalavathy, N; Mohammad, H S; Hariprasad, A; Kumar, C Ravi

    2015-01-01

    Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.

  4. Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

    Science.gov (United States)

    Chen, Junning; Ahmad, Rohana; Suenaga, Hanako; Li, Wei; Sasaki, Keiichi; Swain, Michael; Li, Qing

    2015-01-01

    With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD), to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE) model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO) technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT), potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM) for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption.

  5. Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

    Directory of Open Access Journals (Sweden)

    Junning Chen

    Full Text Available With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD, to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT, potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption.

  6. Shape Optimization for Additive Manufacturing of Removable Partial Dentures - A New Paradigm for Prosthetic CAD/CAM

    Science.gov (United States)

    2015-01-01

    With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD), to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE) model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO) technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT), potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM) for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption. PMID:26161878

  7. Removable partial dentures: clinical concepts.

    Science.gov (United States)

    Bohnenkamp, David M

    2014-01-01

    This article provides a review of the traditional clinical concepts for the design and fabrication of removable partial dentures (RPDs). Although classic theories and rules for RPD designs have been presented and should be followed, excellent clinical care for partially edentulous patients may also be achieved with computer-aided design/computer-aided manufacturing technology and unique blended designs. These nontraditional RPD designs and fabrication methods provide for improved fit, function, and esthetics by using computer-aided design software, composite resin for contours and morphology of abutment teeth, metal support structures for long edentulous spans and collapsed occlusal vertical dimensions, and flexible, nylon thermoplastic material for metal-supported clasp assemblies. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The attitude of complete denture wearers towards denture adhesives in Istanbul

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; Arikan, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture

  9. Supramolecular fluorene based materials

    OpenAIRE

    Abbel, R.J.

    2008-01-01

    This thesis describes the use of noncovalent interactions in order to manipulate and control the self-assembly and morphology of electroactive fluorene-based materials. The supramolecular arrangement of p-conjugated polymers and oligomers can strongly influence their electronic and photophysical properties. Therefore, a detailed understanding of such organisation processes is essential for the optimisation of the performance of these materials as applied in optoelectronic devices. In order to...

  10. Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

    Science.gov (United States)

    Farzin, M; Bahrani, F; Adelpour, E

    2013-09-01

    One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.

  11. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  12. The knowledge and attitude of general dentists toward denture adhesives in Tehran

    Directory of Open Access Journals (Sweden)

    Fakhri Hamidreza

    2009-01-01

    Full Text Available Background: The purpose of this study was to generate discussion and communication among a group of general dentists in Tehran on their viewpoints regarding denture adhesives. Have they accepted denture adhesive as a material to enhance denture retention, stability and function? Materials and Methods: In the summer of 2007, a questionnaire was mailed to 300 general dentists who were assigned with a random systematic sampling method from general dentists in Tehran. The questions were arranged in two parts of evaluating knowledge and attitude. In evaluation of knowledge, dentists were classified into groups of good, moderate, weak and lack of knowledge. In evaluation of attitude, dentists were classified into positive, moderate and negative groups. (Evaluating attitude was carried out in good and moderate groups of knowledge. Results: The study showed that 14%, 32% and 37% of the general dentists had respectively good, moderate and weak knowledge toward denture adhesive while 16.3% had no knowledge about this material. In evaluation of attitude through dentists with positive and moderate knowledge toward denture adhesive, 9.3%, 71.3% and 19.4% had respectively positive, moderate and negative attitude toward denture adhesive. The χ2 test showed a significant statistical relation between situation of knowledge and experiences of dentists. Discussion: This study demonstrated that the rate of knowledge of these 300 general dentists in Tehran towards denture adhesives has not been in a good situation. It is believed that denture adhesive be able to enhance the fitness of a denture and provide psychological relief to the patient. Dentists agreed that education, not only for practitioners but also for patients, would raise the advantageous features and reduce the misuse of denture adhesive. Education of the topic "Denture adhesive" should be more concerned in dental universities.

  13. Inhibitory effects of Lactobacillus rhamnosus and Lactobacillus casei on Candida biofilm of denture surface.

    Science.gov (United States)

    Song, Young-Gyun; Lee, Sung-Hoon

    2017-04-01

    Candida albicans biofilm is associated with denture-related stomatitis and oral candidiasis of elderly. Probiotics are beneficial bacteria and have antibacterial activity against pathogenic bacteria. The purpose of this study was to investigate the antifungal activity of various probiotics against C. albicans and the inhibitory effects of probiotics on Candida biofilm on the denture surface. The spent culture media of various probiotics were investigated the antifungal efficacy against C. albicans. Candida biofilm was formed on a denture base resin and was then treated with Lactobacillus rhamnosus and Lactobacillus casei. Also, the biofilms of L. rhamnosus and L. casei were formed and were sequentially treated with C. albicans. Colony-forming units of C. albicans on the denture surface were counted after spreading on agar plate. The denture base resin was treated with the spent culture media for 30days, after which the denture surface roughness was analyzed with an atomic force microscope. L. rhamnosus and L. casei exhibited stronger antifungal activity than other probiotics. The spent culture medium of L. rhamnosus and L. casei exhibited the antifungal activity against blastoconidia and biofilm of C. albicans. L. rhamnosus and L. casei showed the antifungal activity against Candida biofilm, and the biofilm of L. rhamnosus and L. casei inhibited formation of Candida biofilm on denture surface. Neither of the probiotics affected the surface roughness of the denture base resin. L. rhamnosus and L. casei may be the ideal probiotics for the prevention and treatment of denture-related stomatitis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Supramolecular fluorene based materials

    NARCIS (Netherlands)

    Abbel, R.J.

    2008-01-01

    This thesis describes the use of noncovalent interactions in order to manipulate and control the self-assembly and morphology of electroactive fluorene-based materials. The supramolecular arrangement of p-conjugated polymers and oligomers can strongly influence their electronic and photophysical

  15. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report.

    Science.gov (United States)

    Hazari, Puja; Mishra, Sunil Kumar

    2015-08-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section over the anterior knife-edge ridge. The weight provided retention and stability while the hollow portion prevented further resorption of the bone.

  16. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    Science.gov (United States)

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (Padhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014

  17. Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.

    Science.gov (United States)

    Jei, J Brintha; Mohan, Jayashree

    2014-03-01

    The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.

  18. Removable partial dentures: The clinical need for innovation.

    Science.gov (United States)

    Campbell, Stephen D; Cooper, Lyndon; Craddock, Helen; Hyde, T Paul; Nattress, Brian; Pavitt, Sue H; Seymour, David W

    2017-09-01

    The number of partially dentate adults is increasing, and many patients will require replacement of missing teeth. Although current treatment options also include fixed partial dentures and implants, removable partial dentures (RPDs) can have advantages and are widely used in clinical practice. However, a significant need exists to advance materials and fabrication technologies because of the unwanted health consequences associated with current RPDs. The purpose of this review was to assess the current state of and future need for prosthetics such as RPDs for patients with partial edentulism, highlight areas of weakness, and outline possible solutions to issues that affect patient satisfaction and the use of RPDs. The data on treatment for partial edentulism were reviewed and summarized with a focus on currently available and future RPD designs, materials, means of production, and impact on oral health. Data on patient satisfaction and compliance with RPD treatment were also reviewed to assess patient-centered care. Design, materials, ease of repair, patient education, and follow-up for RPD treatment all had a significant impact on treatment success. Almost 40% of patients no longer use their RPD within 5 years because of factors such as sociodemographics, pain, and esthetics. Research on RPD-based treatment for partial edentulism for both disease-oriented and patient-centered outcomes is lacking. Future trials should evaluate new RPD materials and design technologies and include both long-term follow-up and health-related and patient-reported outcomes. Advances in materials and digital design/production along with patient education promise to further the application of RPDs and improve the quality of life for patients requiring RPDs. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Multifactorial risk assessment for survival of abutments of removable partial dentures based on practice-based longitudinal study.

    Science.gov (United States)

    Tada, Sayaka; Ikebe, Kazunori; Matsuda, Ken-Ichi; Maeda, Yoshinobu

    2013-12-01

    Predicting the tooth survival is such a great challenge for evidence-based dentistry. To prevent further tooth loss of partially edentulous patients, estimation of individualized risk and benefit for each residual tooth is important to the clinical decision-making. While there are several reports indicating a risk of losing the abutment teeth of RPDs, there are no existing reports exploring the cause of abutment loss by multifactorial analysis. The aim of this practice-based longitudinal study was to determine the prognostic factors affecting the survival period of RPD abutments using a multifactorial risk assessment. One hundred and forty-seven patients had been previously provided with a total of 236 new RPDs at the Osaka University Dental Hospital; the 856 abutments for these RPDs were analyzed. Survival of abutment teeth was estimated using the Kaplan-Meier method. Multivariate analysis was conducted by Cox's proportional hazard modelling. The 5-year survival rates were 86.6% for direct abutments and 93.1% for indirect abutments, compared with 95.8% survival in non-abutment teeth. The multivariate analysis showed that abutment survival was significantly associated with crown-root ratio (hazard ratio (HR): 3.13), root canal treatment (HR: 2.93), pocket depth (HR: 2.51), type of abutments (HR: 2.19) and occlusal support (HR: 1.90). From this practice-based longitudinal study, we concluded that RPD abutment teeth are more likely to be lost than other residual teeth. From the multifactorial risk factor assessment, several prognostic factors, such as occlusal support, crown-root ratio, root canal treatment, and pocket depth were suggested. These results could be used to estimate the individualized risk for the residual teeth, to predict the prognosis of RPD abutments and to facilitate an evidence-based clinical decision making. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Collation of chewing efficiency and dentures with diverse occlusal schemes

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Peddinti

    2017-01-01

    Full Text Available Background: Rehabilitation of an edentulous patient nurtures satisfaction and this lies in the chewing ability provided by the prosthesis. Aim: To evaluate and compare the masticatory efficiencies of complete dentures with different occlusal schemes. Materials and Methods: Fourteen completely edentulous patients from the age group of 50-70 years were selected according to the inclusion criteria followed in this study. The dentures were made with three different occlusal schemes, i.e., anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion and stored in water till the date of denture insertion. Post-insertion instructions were given to the patients at the time of delivery of the dentures. Patients were recalled after seven days and then masticatory efficiency was performed. The test was performed using boiled peanuts and Sieve system. Statistical Analysis: One-way analysis of variance (ANOVA test and unpaired t-test were carried out. Results: The obtained masticatory efficiency values with anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion LO were analyzed using one-way ANOVA test and unpaired “t” test. The tests showed that lingualized scheme had highest masticatory efficiency. Conclusion: Within the scope of this study, it can be concluded that the masticatory efficiency will be generally higher in patients provided with complete dentures fabricated using the lingualized occlusal scheme.

  1. Denture plaque--past and recent concerns.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  2. Socio-Demographic and Economic Factors Affecting the Acceptance of Removable Dentures

    Science.gov (United States)

    Baran, İlgi; Ergün, Gülfem; Semiz, Mustafa

    2007-01-01

    Objectives The aim of this study was to evaluate relationships between the socio-demographic and economic factors of patients and the reasons of admission, usage periods of the two types of clinics, frequencies of denture changes, satisfaction levels and preferences of prosthetic dental treatment. Materials and Methods 510 partially and/or totally edentulous patients were studied using a questionnaire. The questionnaire consisted of questions; age, gender, education level, income status, problems with dentures, necessity for new dentures. Also asked was the place that the subjects would prefer to get their denture treatment, irrespective of their income level. In this study, Z-test was used to analyze two-sample proportions, T-test was used to determine two-sample means and Chi-square test was used to determine relationship between two classified variables. Results The number of male patients with complete dentures was more than the number of females, with an opposing trend for partial dentures. Irrespective of gender, each patient had had nearly two dentures by the time of questioning. It was also observed that the university clinics were generally preferred by patients from higher income levels with a higher educational level (x2=25.206, Pdenture treatment, regardless of cost, private practice was the preferred-choice. Conclusions With respect to dental condition and the acceptance of removable dentures, there were differences among gender, educational level and income status. PMID:19212485

  3. Detection of improvement in the masticatory function from old to new removable partial dentures using mixing ability test.

    Science.gov (United States)

    Asakawa, A; Fueki, K; Ohyama, T

    2005-09-01

    The aim of this study was to determine the sensitivity of the Mixing Ability Test to detect improvement of masticatory function in subjects on transition from old to new removable partial dentures. Thirty-two subjects (seven males, 25 females, mean age 65.0 years) with distal extension partially edentulous area in mandible and/or maxilla participated in the study. The following reasons were presented for replacing the old removable partial dentures with new ones: fracture and/or poor fitness of retainers, extraction of abutment teeth, poor fitness of denture base, severe wear of artificial teeth and request for metal base dentures. Masticatory function with old and new removable partial dentures after an adaptation period (mean 27.4 weeks) was evaluated by the Mixing Ability Test. Subjects were asked to masticate five two-coloured wax cubes with each removable partial denture. Mixing Ability Index was obtained from the colour mixture and shape of the masticated cubes. Wilcoxon signed-rank test was used to test the difference of Mixing Ability Indexes between old and new removable partial dentures. The mixing ability indexes with new removable partial dentures (mean+/- s.d.: 0.70+/- 0.68) was significantly higher (Premovable partial dentures (-0.11+/-1.13). The results suggest that the Mixing Ability Test was capable of detecting improvement in masticatory function with new removable partial dentures.

  4. Developing a software for removable partial denture design: Part II: Introduction of RPD graph software

    Directory of Open Access Journals (Sweden)

    Nejatidanesh F

    2007-06-01

    Full Text Available Background and Aim: Designing removable partial dentures is one of the most important phases of prosthetic treatments. Computer can be used to facilitate and increase accuracy of removable partial denture design. The aim of this study was to develop a software for removable partial denture design.Materials and Methods: A questionnaire (discussed in part I and major textbooks, were used to determine the design rules.  The software (RPD Graph was developed using Visual C++ and Maryam program. The RPD Graph can determine the classification of partial edentulous arch. With defining the missing teeth and providing data about prognosis and conditions of abutment teeth, the removable partial design will be developed by RPD Graph. This software is a knowledge-based system which has specific characteristics. It can be used as an educational tool for teaching RPD design and as a clinical tool for supporting clinician's decision. In addition it can be developed to more complete softwares.

  5. Effects of the peracetic acid and sodium hypochlorite on the colour stability and surface roughness of the denture base acrylic resins polymerised by microwave and water bath methods.

    Science.gov (United States)

    Fernandes, Flavio H C N; Orsi, Iara A; Villabona, Camilo A

    2013-03-01

    This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave) used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. Specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, ten test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 minutes, with measurements being taken after each immersion period. These data were submitted to statistical analysis. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. Disinfection with 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the resins. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  6. Enhancing retention of partial dentures using elastomeric retention rings

    Directory of Open Access Journals (Sweden)

    Kakkirala Revathi

    2015-01-01

    Full Text Available This report presents an alternative method for the retention of partial dentures that relies on the engagement of tooth undercuts by a lining material. The lab procedures are also presented. A new maxillary and mandibular acrylic partial dentures were fabricated using elastomeric retention technique for a partially dentate patient. A partially dentate man reported difficulty in retaining his upper removable partial denture (RPD. The maxillary RPD was designed utilizing elastomeric retention technique. During follow-up, it was necessary to replace the retention rings due to wear. The replacement of the retention rings, in this case, was done through a chairside reline technique. Elastomeric retention technique provides exceptionally good retention can be indicated to stabilize, cushion, splint periodontally involved teeth, no enough undercut for clasps, eliminate extractions, single or isolated teeth.

  7. Poor oral hygiene, wearing dentures at night, perceptions of mouth dryness and burning, and lower educational level may be related to oral malodor in denture wearers.

    Science.gov (United States)

    Garrett, Neal R

    2010-03-01

    The study sample was recruited from edentulous patients seeking new dentures at the Kirikkale University Denture Clinic, Turkey. Male (n = 56) and female (n = 49) participants were enrolled and ranged from 50 to 78 years of age (mean age 60.7 6 7.7 years). All 105 completed baseline evaluations, new denture therapy, and follow-up examination approximately 4 weeks after denture treatment completion. The study was approved by the institution's Ethics Committee. Dates for patient recruitment and conduct of the study were not provided. For the prognostic component of the study, the primary factors of interest were sociodemographic characteristics, medical conditions previously related to oral malodor, and self-reported oral hygiene habits. The primary exposure for the interventional component was oral hygiene instruction, including brushing the tongue, cleaning the denture, and not wearing the denture at night. After treatment with new dentures, participants were instructed to follow these hygiene instructions daily and were evaluated 4 weeks later. The primary outcome measure was the degree of oral malodor with the original conventional dentures and following new denture treatment and oral hygiene instruction with 4 weeks of self-administered hygiene care. Oral malodor was expressed both quantitatively as the number of parts per billion (ppb) of volatile sulfide compounds (VSCs) and as a binary measure (present/absent) based on a threshold for oral malodor of greater than 110 ppb. Significant relationships with oral malodor (level of VSCs) at baseline with the original denture were found for education (those having only primary school education were more likely to have higher VSC level, odds ratio [OR] 8.6, P = .046), self-reported oral dryness (OR 2.5, P = .037), self-reported overnight denture wear (OR 0.342 [likely a typographical error in the table; based on the 95% CI of 1.59 to 8.35, the OR is probably 3.42], P = .002), and level of bacterial plaque coverage on

  8. [Removable partial dentures. Oral functions and types

    NARCIS (Netherlands)

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic

  9. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  10. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction

    NARCIS (Netherlands)

    Wismeijer, D.; Tawse-Smith, A.; Payne, A.G.T.

    2013-01-01

    Objective To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. Materials and methods Forty-eight participants who were dissatisfied with their existing conventional mandibular

  11. The effect of denture stability, occlusion, oral hygiene and smoking on denture-induced stomatitis

    International Nuclear Information System (INIS)

    Nimri, Gadeer Mukatash

    2008-01-01

    This longitudinal clinical investigation was undertaken to find out the effect of denture wearing habit (day versus day and night), denture hygiene and cigarette smoking habit on the frequency of denture induced stomatitis. Comparisons were made between 240 complete denture wearers, half of whom were asked to wear their dentures at the daytime only and the other half to wear the denture day and night. All these participants were male patients with a mean age of 57.6 years who had received maxillary complete acrylic dentures for the first time. Fifty percent of the samples were smokers. A standard method for examination of the mouth and denture construction, insertion and follow up were employed. Putative risk factors (denture wearing habits, denture hygiene and smoking) were investigated. Subjects were recalled 12 months after insertion to examine the quality of the denture and the condition of the maxillary mucosa. No significant correlation was found between deterioration of stability or occlusion and type of habitual use of the dentures (P > 0.05). Fourteen percent of the cases reported with inflamed maxillary mucosa. Deterioration of retention or occlusion separately showed no correlation with the condition of the mucosa. However, associated deterioration of both stability and occlusion proved to be significantly correlated with the occurrence of denture stomatitis (P < 0.05). Denture stomatitis was significantly more frequently with subjects wearing their dentures overnight compared with those who removed them (P < 0.05). A significant correlation was also found between cigarette smoking, poor oral hygiene and the presence of denture induced stomatitis (P < 0.05). Nocturnal denture wearing habit, deficient oral and denture hygiene, and cigarette smoking are all important predisposing factors to denture-induced stomatitis, however, none of these factors was the sole cause of mucosal inflammation. (author)

  12. Denture Adhesives in Prosthodontics: An Overview.

    Science.gov (United States)

    Kumar, P Ranjith; Shajahan, P A; Mathew, Jyothis; Koruthu, Anil; Aravind, Prasad; Ahammed, M Fazeel

    2015-01-01

    The use of denture adhesives is common among denture wearers, and it is also prescribed by many dentists. Prescribing denture adhesives has been viewed by many prosthodontists as a means of compensating for any defects in the fabrication procedures. Denture adhesives add to the retention and thereby improve chewing ability, reduce any instability, provide comfort and eliminate the accumulation of food debris beneath the dentures. Consequently, they increase the patient's sense of security and satisfaction. However, obtaining the advice of the dental practitioner prior to the use of adhesives is a must.

  13. Materials engineering data base

    Science.gov (United States)

    1995-01-01

    The various types of materials related data that exist at the NASA Marshall Space Flight Center and compiled into databases which could be accessed by all the NASA centers and by other contractors, are presented.

  14. Antimicrobial activity of denture adhesive associated with Equisetum giganteum- and Punica granatum-enriched fractions against Candida albicans biofilms on acrylic resin surfaces.

    Science.gov (United States)

    Almeida, Nara Ligia Martins; Saldanha, Luiz Leonardo; da Silva, Rafaela Alves; Pinke, Karen Henriette; da Costa, Eliane Ferraz; Porto, Vinicius Carvalho; Dokkedal, Anne Lígia; Lara, Vanessa Soares

    2018-01-01

    Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.

  15. Trends in complete denture impressions in pakistan

    International Nuclear Information System (INIS)

    Vohra, F.; Rashid, H.; Hanif, A.

    2015-01-01

    Multiple materials and techniques have been reported for complete denture impressions in literature. The aim of the study was to assess the trends in complete denture impression materials and techniques among general dental practitioners (GDP) and specialists (SP) in Pakistan. Methods: In this cross-sectional study, self-designed-structured questionnaires were distributed among 500 dentists in Pakistan. The three-part questionnaire enquired about the demographic features, preferred impression materials, impression techniques and related procedures commonly used in their clinical practice. A comparison between the responses of SP and GDP was also drawn. Frequency distribution and Chi-square test were performed to compare the responses. Results: A total of 294 questionnaires were completed at a response rate of 58.8%. 75% of GDP used alginate for primary impressions and 66% of SP preferred impression compound for the same. A majority of both SP and GDP favoured the used of custom trays (SP 81%, GDP 85%) and selective pressure technique (SP 84%, GDP 53%) for final impression. However, 85% of GDP used zinc-oxide eugenol and 62% of SP favoured elastomeric materials for the same. Most of the SP and GDP used chemical cured resin custom trays (SP 54%, GDP 75%), however, 86% of SP used spaced trays and almost 60% of GDP preferred close-fitting trays. Conclusions: The practice of GDP and SP with regards to CD impression materials and techniques differed significantly. Continued education and training for GDP and SP with respect to procedures and techniques related to CD is recommended. (author)

  16. The effect of cocoa (Theobroma cacao L on the basic color stability of thermoplastic nylon resin dentures

    Directory of Open Access Journals (Sweden)

    Amiyatun Naini

    2011-11-01

    Full Text Available Nylon thermoplastic resin is material of choice for the making of flexible. This denture do not use wire retention, but has the physical properties of water absorption. In the oral cavity, it will always be in contact with food and beverages consumed. One of the foods that are consumed by the public is chocolate. This study aimed to determine the effect of cocoa (Theobroma cacao L on color stability of the thermoplastic nylon denture base. The study sample was thermoplastic nylon (valplast with a size of 10x10x2 mm soaked in the chocolate solution for 7 and 14 days. As the control, the sample soaked with distilled water. The color testing stability used was densitometer. There were significant differences between the control group (distilled water and the chocolate solution. This was due to dissolved components/tannin having a capillary flow diffusion into thermoplastic nylons that causing discoloration. The conclusion of this study, there was the effect of cocoa (Theobroma cacao L against the color stability of the nylon thermoplastic denture base. The longer time of immersion of nylon thermoplastic the greater the change in color.

  17. The Split Denture: Managing Xerostomia in Denture Patients: A Case Report

    OpenAIRE

    Dabas, Nupur; Phukela, Sumit Singh; Yadav, Harish

    2011-01-01

    Wearing complete dentures can be an extremely uncomfortable experience for the people with Xerostomia. Various treatment modalities have been suggested in the literature to overcome the problem of xerostomia in complete denture patients. Incorporating reservoirs containing salivary substitutes, into dentures, is one of these treatment modalities. This paper presents case report of a patient suffering from xerostomia who was successfully treated with a new form of reservoir dentures. This new ...

  18. Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study.

    Science.gov (United States)

    Dula, Linda J; Ahmedi, Enis F; Lila-Krasniqi, Zana D; Shala, Kujtim Sh

    2015-01-01

    The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at pdenture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD's, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp pdentures and below the clasp arms in abutment teeth.

  19. [Selection of occlusal scheme on the basis of pressure distribution on supporting structures under complete dentures].

    Science.gov (United States)

    Nagao, Kan; Kawano, Fumiaki; Ichikawa, Tetsuo

    2004-12-01

    In case of making complete dentures, we have to consider not only denture stability but also the restoration of aesthetics and function such as mastication and speech. However these are contradictory theoretically from the point of view of denture stability, and it is very difficult to satisfy both requirements in the case of a patient who has poor upper and lower alveolar ridges. We investigated the effect of artificial posterior teeth form and occlusal scheme on the distribution of pressure on supporting structures under complete dentures during mastication with upper and lower edentulous simulators. In this report, a guideline for the selection of occlusal scheme for complete dentures, based on our previous investigations, is described. The occlusal scheme remarkably affected the distribution of pressure under simulated complete dentures, as shown by comparing the distribution of pressure using two different occlusal schemes:fully balanced occlusion and lingualized occlusion. However other factors such as posterior teeth form and position affect the distribution of pressure as well, and are related to each other. Therefore, not only occlusal scheme but also posterior artificial teeth form has to be considered, and the form of posterior teeth should be carefully and comprehensively decided when making complete dentures.

  20. [Principles of bone tissue structures interaction with full removable dentures fixed on intraosseous implantates modelling].

    Science.gov (United States)

    Shashmurina, V R; Chumachenko, E N; Olesova, V N; Volozhin, A I

    2008-01-01

    Math modelling "removable dentures-implantate-bone" with size and density of bone tissue as variables was created. It allowed to study biomechanical bases of mandibular bone tissue structures interaction with full removable dentures of different constructions and fixed on intraosseous implantates. Analysis of the received data showed that in the majority of cases it was expedient to recommend 3 bearing (abutments) system of denture making. Rest on 4 and more implantates was appropriate for patients with reduced density of spongy bone and significant mandibular bone atrophy. 2 abutment system can be used in patients with high density of spongy bone and absence of mandibular bone atrophy.

  1. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    Science.gov (United States)

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  2. Educational Process Material Base

    OpenAIRE

    Olga Ozerova; Irina Zabaturina; Vera Kuznetsova; Galina Kovaleva

    2012-01-01

    Based on the data obtained by the Institute for Statistical Studies and the Economics of Knowledge, National Research University - Higher School of Economics Olga Ozerova - Head of the Department for Statistics of Education, Institute for Statistical Studies and the Economics of Knowledge, National Research University - Higher School of Economics, Moscow, Russian Federation. Email: Address: 18 Myasnitskaya St., Moscow, 101000, Russian Federation.Irina Zabaturina - senior resea...

  3. Candida colonization on the denture of diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Lotfi-Kamran

    2009-01-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection in diabetic patients. Presence of denture in the oral cavity of diabetic patients can promote Candida colonization and results in the higher incidence of oral and systemic candidiasis. The general purpose of the present study was to evaluate and compare Candida colonization in denture of diabetic patients and non-diabetic control group. Methods: In current case-control study, samples for mycological examinations were collected from the palatal impression surface of maxillary dentures from 92 edentulous patients including 46 dia-betic and 46 non-diabetic denture wearers. All samples were cultured directly on sabouraud agar me-dium and isolated colonies were counted and identified based on specific tests. Data were statistically analyzed using Mann-Whitney and Spearman correlation tests. Results: The higher density of isolated colonies was seen in diabetic group in compare with control group (P = 0.0001. There was a statistically significant correlation between the blood glucose level (P = 0.0001 and the duration of denture usage (P = 0.022 with the colonization of Candida on den-ture of diabetic patients. C. albicans was the most common isolated Candida species in both groups, though diabetic patients with dentures had more non-albicans Candida isolated from their dentures compared to non-diabetic patients. Conclusions: Mycological findings from the present study revealed that diabetes mellitus can in-crease colonization of Candida in denture and mouth. By elimination of local and systemic factors in diabetic patients and improving their oral health care, Candida colonization and the risk of oral and systemic candidiasis will be decreased.

  4. Fabrication and physical properties of glass-fiber-reinforced thermoplastics for non-metal-clasp dentures.

    Science.gov (United States)

    Nagakura, Manamu; Tanimoto, Yasuhiro; Nishiyama, Norihiro

    2017-11-01

    Recently, non-metal-clasp dentures (NMCDs) made from thermoplastic resins such as polyamide, polyester, polycarbonate, and polypropylene have been used as removable partial dentures (RPDs). However, the use of such RPDs can seriously affect various tissues because of their low rigidity. In this study, we fabricated high-rigidity glass-fiber-reinforced thermoplastics (GFRTPs) for use in RPDs, and examined their physical properties such as apparent density, dynamic hardness, and flexural properties. GFRTPs made from E-glass fibers and polypropylene were fabricated using an injection-molding. The effects of the fiber content on the GFRTP properties were examined using glass-fiber contents of 0, 5, 10, 20, 30, 40, and 50 mass%. Commercially available denture base materials and NMCD materials were used as controls. The experimental densities of GFRTPs with various fiber contents agreed with the theoretical densities. Dynamic micro-indentation tests confirmed that the fiber content does not affect the GFRTP surface properties such as dynamic hardness and elastic modulus, because most of the reinforcing glass fibers are embedded in the polypropylene. The flexural strength increased from 55.8 to 217.6 MPa with increasing glass-fiber content from 0 to 50 mass%. The flexural modulus increased from 1.75 to 7.42 GPa with increasing glass-fiber content from 0 to 50 mass%, that is, the flexural strength and modulus of GFRTP with a fiber content of 50 mass% were 3.9 and 4.2 times, respectively, those of unreinforced polypropylene. These results suggest that fiber reinforcement has beneficial effects, and GFRTPs can be used in NMCDs because their physical properties are better than those of controls. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2254-2260, 2017. © 2016 Wiley Periodicals, Inc.

  5. Patient's Satisfaction with Removable Partial Dentures: A Retrospective Case Series.

    Science.gov (United States)

    Shala, Kujtim Sh; Dula, Linda J; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient's satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient's satisfaction with RPD with or without attachment. Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.

  6. Polyphosphazine-based polymer materials

    Science.gov (United States)

    Fox, Robert V.; Avci, Recep; Groenewold, Gary S.

    2010-05-25

    Methods of removing contaminant matter from porous materials include applying a polymer material to a contaminated surface, irradiating the contaminated surface to cause redistribution of contaminant matter, and removing at least a portion of the polymer material from the surface. Systems for decontaminating a contaminated structure comprising porous material include a radiation device configured to emit electromagnetic radiation toward a surface of a structure, and at least one spray device configured to apply a capture material onto the surface of the structure. Polymer materials that can be used in such methods and systems include polyphosphazine-based polymer materials having polyphosphazine backbone segments and side chain groups that include selected functional groups. The selected functional groups may include iminos, oximes, carboxylates, sulfonates, .beta.-diketones, phosphine sulfides, phosphates, phosphites, phosphonates, phosphinates, phosphine oxides, monothio phosphinic acids, and dithio phosphinic acids.

  7. Effect of long-time immersion of soft denture liners in water on viscoelastic properties.

    Science.gov (United States)

    Iwasaki, Naohiko; Yamaki, Chisato; Takahashi, Hidekazu; Oki, Meiko; Suzuki, Tetsuya

    2017-09-26

    Aim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months. Viscoelastic properties, which were instantaneous and delayed elastic displacements, viscous flow, and residual displacement, were determined using a creep meter, and analyzed with 2-way analysis of variance and Tukey's comparison (α=0.05). Viscoelastic properties and their time-dependent changes were varied among materials examined. The observed viscoelastic properties of three from six silicone-based liners did not significantly change after 6-month immersion, but those of two acrylic resin-based liners significantly changed with the increase of immersion time. However, the sum of initial instantaneous elastic displacement and delayed elastic displacement of two acrylic resin-based liners during 6-month immersion changed less than 10%, which might indicate clinically sufficient elastic performance.

  8. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  9. Synthesis of Plaster for moulers's elaboration of imprint denture

    International Nuclear Information System (INIS)

    Hamiane, M; Rabahi, N; Saidi, M; Salhi, M

    2012-01-01

    Our goal was the synthesis of plaster from local raw materials to be used in denture mouler's. The plaster type α and β was synthesis by hydrothermal and dry method from gypsum (CaSO4. 2H2O) of the west Algerian. After crushing and mineralogical analysis, gypsum has undergone through cooking in an oven at a temperature (T = 200 ° C), for a time t = 4 hours. The synthesis and characterization of the product has involved several ways investigated as diffraction RX, X-ray fluorescence, time taken, electron microscope (MEB), hardness, SSB, compressive and bending strength and Ph. A digester horizontal type Toni - technical laboratory was used for the synthesis of plasterα. The results are conformable with the standard and plaster synthesized can be a basic material in the manufacture of moulers imprint denture.

  10. Synthesis of Plaster for moulers's elaboration of imprint denture

    Science.gov (United States)

    Hamiane, M.; Rabahi, N.; Saidi, M.; Salhi, M.

    2012-02-01

    Our goal was the synthesis of plaster from local raw materials to be used in denture mouler's. The plaster type α and β was synthesis by hydrothermal and dry method from gypsum (CaSO4. 2H2O) of the west Algerian. After crushing and mineralogical analysis, gypsum has undergone through cooking in an oven at a temperature (T = 200 ° C), for a time t = 4 hours. The synthesis and characterization of the product has involved several ways investigated as diffraction RX, X-ray fluorescence, time taken, electron microscope (MEB), hardness, SSB, compressive and bending strength and Ph. A digester horizontal type Toni - technical laboratory was used for the synthesis of plasterα. The results are conformable with the standard and plaster synthesized can be a basic material in the manufacture of moulers imprint denture.

  11. Implant retainers for free-end removable partial dentures affect mastication and nutrient intake.

    Science.gov (United States)

    Campos, Camila Heitor; Gonçalves, Thais Marques Simek Vega; Rodrigues Garcia, Renata Cunha Matheus

    2014-08-01

    This study measured swallowing threshold parameters and nutrient intake in partially dentate subjects rehabilitated by conventional free-end removable partial dentures (RPD) and by RPD over posterior implant retainers and ball attachments (BA). Eight subjects (two men and six women; mean age 60.1 ± 6.6 years old) received conventional total maxillary dentures and free-end RPD in the mandible. Two months after denture insertion, swallowing threshold and nutrient intake assessments occurred, which included an evaluation of the number of masticatory cycles and medium particle size (X₅₀) of a silicone test material (Optocal). A 3-day food diary verified nutrient intake based on a standard Brazilian Food Composition Table. Then, osseointegrated implants were placed bilaterally in the mandibular first molar region, followed by BA, which was fitted in the RPD bases after healing. After 2 months of the RPD over implants and BA use, variables were again assessed. Wilcoxon signed rank tests evaluated the data (P 0.05); however, subjects showed decreased X₅₀ values at the swallowing moment (P = 0.008) and increased daily energy (P = 0.008), carbohydrate (P = 0.016), protein (P = 0.023), calcium (P = 0.008), fiber (P = 0.016), and iron (P = 0.016) intake with RPD implants and BA inserts. No differences were found in fat consumption (P > 0.05). Implants and BA retainers over a free-end RPD resulted in smaller swallowed median particle size and improved nutrient intake. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  12. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    Science.gov (United States)

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  13. Photodynamic antimicrobial therapy in the treatment of denture stomatitis

    International Nuclear Information System (INIS)

    Senna, Andre Machado de

    2012-01-01

    Denture stomatitis (DS), also called chronic atrophic candidiasis, is the most common oral fungal infection in denture wearers. It has a multifactorial etiology, but the presence of Candida spp. biofilm on the denture is considered the most important factor for the establishment of the DS. This study aimed to evaluate the treatment of DS through the use of photodynamic antimicrobial therapy (PAT), mediated by methylene blue. For this purpose, preclinical studies and clinical trials were performed. Simulators prototypes dentures were made of methyl methacrylate polymer to serve as a basis for biofilm growth of the following species of Candida: C. albicans, C. glabrata, C. dubliniensis, C. krusei, C. tropicalis, C. parapsilosis and C. guilliermondii. Methylene blue solution at a concentration of 450 μg/mL was used as a photosensitizer. The prototypes and biofilms were irradiated with a laser of wavelength of 660 nm, potency of 100 mW, for 80 seconds. For the clinical study, subjects were divided into two groups. The first group received conventional treatment based on the use of antifungal Miconazole. The second group received the treatment by PAT. The preclinical results showed that all species of the genus Candida were susceptible to PAT, with a reduction in colonies that ranged from 2.48 to 3.93 log 10 . Clinical outcomes were evaluated for the reduction of colonies of Candida spp. located in the mucosa and in the prosthesis and relative to the improvement of the clinical aspect of the affected mucosa. Both the conventional therapy and PAT were effective in treating DS. There was no significant statistical difference between PAT and conventional treatment for any of the factors evaluated. Thus, it was concluded that PAT is effective in the treatment of denture stomatitis. (author)

  14. Evaluation of denture hygiene among removable denture wearers referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Molouk Torabi Parizi

    2013-06-01

    Full Text Available BACKGROUND AND AIM: The number of patients who need prosthetic treatments has increased. Efficient and regular procedures for cleaning removable dentures are important for maintaining good oral health. The aim of this study was to analyze the oral and prostheses care habits of removable denture users, who attended the clinics of Kerman, Iran. METHODS: This cross-sectional study was carried out on 350 patients, who attended the clinics of Kerman and were chosen by the multistage sampling method. Data were obtained from a checklist consisting of demographic characteristics (age, sex, educational level, kind of prosthesis, age of prosthesis, self-report of halitosis, and smoking status, denture hygiene habits, denture-wearing behavior, and cleanliness of denture by examiner. Data was analyzed using chi-squared test (P < 0.05. RESULTS: The mean age of patients was 58.52 ± 10.78 years, 103 (29.4% were male and 247 (70.6% were female. The results showed that 78.6% had complete denture and 12.7% reported halitosis, 55.1% used their denture at night, and 36.4% had poor denture hygiene. Brushing was the most used cleaning method by the patients (36.5%. 60.4% reported never having been instructed by their dentists as to how to clean their dentures. 58.6% had been using the same denture for more than 5 years. There was a significant correlation between the kind of denture, and denture hygiene and education level. CONCLUSION: According to the results of the present study denture hygiene was not favorable. Therefore, dentists should instruct the patients on cleaning their denture in order to prevent denture–induced lesions.

  15. Analysis of the effects of removable dentures on the psychological status, quality of life, and masticatory function of the elderly

    Science.gov (United States)

    Dyas, R.; Nathanael, M.; Indrasari, M.; Masulili, C.; Rahardjo, T. B.; Agustin, D.; Hogervorst, E.; Kusdhany, L.

    2017-08-01

    Older age is a major risk factor for diseases of the teeth and mouth and dementia. Diseases of the teeth and mouth can lead to tooth loss. The use of removable dentures can help the elderly to replace lost teeth; therefore, dentures are expected to improve the masticatory function, quality of life, and psychological status of the elderly. The aim of this study was to analyze the effects of removable denture usage on the improvement of the psychological status, quality of life, and masticatory function of elderly people. The data was obtained from 30 respondents. The patients answered questionnaires before they used the dentures, 2 weeks after they began using dentures, and 2 months after they started wearing dentures. Four different questionnaires were used: EuroQol Five Dimensions questionnaire (EQ-5D) and Geriatric Depression Scale (GDS), to measure psychological status; a mastication questionnaire to measure masticatory function; and a validated quality of life questionnaire. Based on the results of this study, it is clear that after 2 months of denture usage, removable dentures in the elderly can significantly improve their quality of life, masticatory function, and psychological status(p<0.05).

  16. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  17. [Designing metal frame removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    Oral health care providers have the full responsibility for designing metal frame removable partial dentures and making all of the necessary preparations. Important principles of design are that the denture should hamper natural cleaning and daily oral hygiene as little as possible and that it

  18. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  19. Effect of post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins Efeito de tratamentos térmicos após a polimerização sobre a citotoxicidade de duas resinas acrílicas para base de próteses

    Directory of Open Access Journals (Sweden)

    Janaina Habib Jorge

    2006-06-01

    Full Text Available INTRODUCTION: Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. ³H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. AIM: The purpose of this study was to investigate, using ³H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins. MATERIALS AND METHODS: Nine disc-shaped specimens (10 x 1 mm of each denture base resin (Lucitone 550 and QC 20 were prepared according to the manufacturers' recommendations and stored in distilled water at 37ºC for 48 h. The specimens were assigned to 3 groups: 1 post-polymerization in a microwave oven for 3 min at 500 W; 2 post-polymerization in water-bath at 55º C for 60 min; and 3 without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle's medium and incubated at 37ºC for 24 h. The cytotoxic effect of the eluates was evaluated by ³H-thymidine incorporation. RESULTS: The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (pINTRODUÇÃO: A maioria das resinas acrílicas utilizadas para confecção de bases de próteses é composta pelo polimetacilato de metila. Muitos autores têm discutido o processo de polimerização dessas resinas em relação à conversão do monômero em polímero devido a sua importância na melhora da

  20. [Study on retention and stability of linear occlusal complete dentures].

    Science.gov (United States)

    Zhang, Ping; Xu, Jun

    2003-01-01

    To learn retention and stability of linear occlusal complete dentures by investigating the subjective feelings of patient and the value of retention force. Static retention forces of maxillary and mandibular dentures were measured for 25 patients wearing linear occlusal dentures by using Hz-1 retention dynamometer. The subjective feelings of patients in functional state were gained simultaneously through questionnaire. Linear occlusal dentures demonstrate good retention in static and dynamic state. Among patients with severe resorption of residual ridge (RRR), mandibular linear occlusal dentures (shown good retentive subjective feelings) demonstrate significantly smaller retention force than those with slight or medium degree of RRR. There is no correlation between the subjective feelings and the values of retention forces of mandibular dentures. The subjective feelings of patients wearing new linear occlusal dentures are much better than that of old anatomic occlusal dentures. Linear occlusal dentures improve the performances of dentures by enhancing their stability during mastication movement.

  1. Effects of denture maintenance on satisfaction levels of Taiwanese elderly using removable partial dentures: a pilot study.

    Science.gov (United States)

    Wu, Ju-Hui; Yang, Yi-Hsin; Wang, Chau-Hsiang; Lee, Huey-Er; Du, Je-Kang

    2012-06-01

    The aim of this study was to evaluate the correlation between patient satisfaction with removable partial dentures and denture maintenance by patients, including regular application of denture adhesives and cleansers. The success of removable partial dentures depends on patient satisfaction with dentures and their regular denture maintenance. Demographic information, the Oral Impacts on Daily Performance (OIDP) indicator and details of denture maintenance (including the use of denture cleansers and adhesives) were collected from 193 (41.5% men and 58.5% women) participants by using questionnaires. A dentist performed oral examinations to evaluate denture function according to the OIDP items photographically and recorded the number of remaining teeth and Kennedy's classification. Most participants were satisfied with their removable partial dentures and tended to have higher satisfaction levels than the dentist's estimation. Further, those using denture adhesives and cleansers had higher satisfaction levels than those not using such denture maintenance. Appropriate education regarding denture use is important because regular denture maintenance by patients affects their degree of satisfaction with dentures, as well as the dentist's skill and the patient's oral condition. Dentists could use this information to predict the potential success of dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  2. An Investigation into the Accuracy of Two Currently Available Dental Impression Materials in the Construction of Cobalt-Chromium Frameworks for Removable Partial Dentures.

    Science.gov (United States)

    Dubal, Rajesh Kumar; Friel, Tim; Taylor, Philip D

    2015-03-01

    This study investigated the suitability of irreversible hydrocolloid as an impression material for cobalt-chromium framework construction. Scans of casts derived from (1) alginate and (2) addition-cured polyvinylsiloxane impressions were superposed on to a control. The differences within and between groups were compared at fixed landmarks. The investigation revealed a high degree of scan coincidence within and between groups. However, certain features, such as undercuts, resulted in a lower degree of scan coincidence. Irreversible hydrocolloid appears to be a viable alternative to addition-cured polyvinyl-siloxane as an impression material for cobalt-chromium framework construction.

  3. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    Science.gov (United States)

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  4. A comparative study to check fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate resin reinforced with different materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Parikshit Gupt

    2017-01-01

    Conclusion: Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.

  5. Method of Retention Control for Compromised Periodontal Bone Support Abutment of Conical Crown Retained Denture

    Directory of Open Access Journals (Sweden)

    Chau-Hsiang Wang

    2010-08-01

    Full Text Available Conical crown-retained dentures (CCRD show a higher survival rate and greater patient satisfaction than transitional removable partial dentures during long-term follow-up. However, unsustainable denture retention force on supporting abutments after initial delivery and loss retention are frequently seen in long-term follow-up of clinical cases. The main causes are insufficient information concerning denture retention designs and the retention-tolerance of the supporting abutments. Monitoring by dental technicians of the quality of dental prostheses is critical. This case report describes an optimal method for CCRD construction that determines and distributes an optimal denture retention force on the supporting abutments to allow the patient to easily remove the denture while ensuring that the CCRD remains in place during physiologic activities. Oral rehabilitation with CCRD should consider the condition of the abutment periodontal support, the interarch occlusal relationship, supplemental fatigue of the terminal abutment, and patient's estimated bite force. The effects of friction on the abutment's inner crown were based on an optimal a angle. The dental laboratory used these measurements to fabricate a CCRD using a Koni-Meter to adjust the retention of the inner crown. This method protects the abutments and reduces the wear between the inner and outer crowns. The CCRD achieved good esthetic results and physiologic functions. Periodic long-term follow-up of the patient and CCRD after initial placement is recommended.

  6. Removable Partial Denture Supported by Implants with Prefabricated Telescopic Abutments - A Case Report

    Science.gov (United States)

    Sehgal, Komal

    2014-01-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy—biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. PMID:25121066

  7. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    Science.gov (United States)

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  8. Effects of incorporation of 2.5 and 5 wt% TiO2 nanotubes on fracture toughness, flexural strength, and microhardness of denture base poly methyl methacrylate (PMMA).

    Science.gov (United States)

    Abdulrazzaq Naji, Sahar; Behroozibakhsh, Marjan; Jafarzadeh Kashi, Tahereh Sadat; Eslami, Hossein; Masaeli, Reza; Mahgoli, Hosseinali; Tahriri, Mohammadreza; Ghavvami Lahiji, Mehrsima; Rakhshan, Vahid

    2018-04-01

    The aim of this preliminary study was to investigate, for the first time, the effects of addition of titania nanotubes (n-TiO 2 ) to poly methyl methacrylate (PMMA) on mechanical properties of PMMA denture base. TiO 2 nanotubes were prepared using alkaline hydrothermal process. Obtained nanotubes were assessed using FESEM-EDX, XRD, and FT-IR. For 3 experiments of this study (fracture toughness, three-point bending flexural strength, and Vickers microhardness), 135 specimens were prepared according to ISO 20795-1:2013 (n of each experiment=45). For each experiment, PMMA was mixed with 0% (control), 2.5 wt%, and 5 wt% nanotubes. From each TiO 2 :PMMA ratio, 15 specimens were fabricated for each experiment. Effects of n-TiO 2 addition on 3 mechanical properties were assessed using Pearson, ANOVA, and Tukey tests. SEM images of n-TiO 2 exhibited the presence of elongated tubular structures. The XRD pattern of synthesized n-TiO 2 represented the anatase crystal phase of TiO 2 . Moderate to very strong significant positive correlations were observed between the concentration of n-TiO 2 and each of the 3 physicomechanical properties of PMMA (Pearson's P value ≤.001, correlation coefficient ranging between 0.5 and 0.9). Flexural strength and hardness values of specimens modified with both 2.5 and 5 wt% n-TiO 2 were significantly higher than those of control ( P ≤.001). Fracture toughness of samples reinforced with 5 wt% n-TiO 2 (but not those of 2.5% n-TiO 2 ) was higher than control ( P =.002). Titania nanotubes were successfully introduced for the first time as a means of enhancing the hardness, flexural strength, and fracture toughness of denture base PMMA.

  9. Mechanical Properties of Surface-Charged Poly(Methyl Methacrylate as Denture Resins

    Directory of Open Access Journals (Sweden)

    Sang E. Park

    2009-01-01

    Full Text Available The aim of this study was to examine the mechanical properties of a new surface-modified denture resin for its suitability as denture base material. This experimental resin is made by copolymerization of methacrylic acid (MA to poly(methyl methacrylate (PMMA to produce a negative charge. Four experimental groups consisted of Orthodontic Dental Resin (DENTSPLY Caulk as a control and three groups of modified PMMA (mPMMA produced at differing ratios of methacrylic acid (5 : 95, 10 : 90, and 20 : 80 MA : MMA. A 3-point flexural test using the Instron Universal Testing Machine (Instron Corp. measured force-deflection curves and a complete stress versus strain history to calculate the transverse strength, transverse deflection, flexural strength, and modulus of elasticity. Analysis of Variance and Scheffe Post-test were performed on the data. Resins with increased methacrylic acid content exhibited lower strength values for the measured physical properties. The most significant decrease occurred as the methacrylic acid content was increased to 20% mPMMA. No significant differences at P<.05 were found in all parameters tested between the Control and 5% mPMMA.

  10. Impact of removable partial denture prosthesis on chewing efficiency

    Science.gov (United States)

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

  11. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  12. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Salloum, Alaa'a M

    2013-10-01

    Despite advances in materials and techniques, complete dentures made of acrylic resin experience an increase in the occlusal vertical dimension (OVD) during processing. Many factors that affect the OVD of complete dentures are known. However, no study has examined the effect of using high-expansion dental stone (type V) as an investing material on the OVD. This study investigated the effects of using a high-expansion dental stone as an investing material on changes in the OVD of complete dentures. Twenty sets of simulated upper and lower dentures were processed by the compression molding technique. Specimens were equally divided into 2 groups. In the dental stone type III (DST III) group, the lower, middle, and upper parts of a flask were filled with DST III. In the dental stone type V (DST V) group, the procedure was the same as in the DST III group, except that the middle layer was made of high-expansion DST V. Changes in the OVD were measured before and after denture processing. Collected data were analyzed with t-test statistics. Differences were considered statistically significant at the 95% confidence level. Both groups showed a small increase in the OVD as a result of processing, but the OVD increase was significantly less in the DST V group compared to the DST III group. High-expansion DST V can be recommended as an investing material to reduce the increase in the OVD that may occur while processing complete dentures.

  13. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  14. Presence of Different Candida Species at Denture Wearers With Type 2 Diabetes and Clinically Healthy Oral Mucosa-Pilot Study

    Directory of Open Access Journals (Sweden)

    Petrović Sanja Matić

    2018-03-01

    Full Text Available Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental groups: systematically health subjects; patients with diagnosed Type 2 Diabetes (T2D and good glycoregulation; and T2D subjects with poorly regulated blood sugar level. Cotton swab samples were obtained from each patient from hard palate mucosa and denture surface. Swab cultures were made on Sabouraud dextrose agar and ChromAgar Media for distinciton of various Candida spp. Density growth was also measured. Results: Frequency of Candida spp. findings were similar between groups. At healthy subjects, only C.albicans was detected. At diabetics, C.albicans was the most common isolated species, followed by C.glabrata and C.tropicalis. Negative finding of yeasts on palatal mucosa, but positive on denture surface were detected at all groups, with the highest frequency (33.4% at diabetics with poor glycoregulation. Denture surface was heavier colonized than hard palate mucosa. Duration of diabetes in years were only independent predictors for harboring Candida spp. at denture surface (Exp B=1.186, CI=1.047-1.344, p=0.007. Conclusions: Prosthesis of denture wearers without DS may serve as reservoir of Candida spp. Presence of more pathogenic and resistant non-albicans species are related to diabetics, even without clinical signs of DS.

  15. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... 2Faculty of Dentistry, the University of Hong Kong, Hong Kong. 3Department of ... an example of poor oral condition caused mainly by periodontitis, and ... working model of the Dual Component Removable Partial Denture.

  16. Removable partial dentures: use of rapid prototyping.

    Science.gov (United States)

    Lima, Julia Magalhaes Costa; Anami, Lilian Costa; Araujo, Rodrigo Maximo; Pavanelli, Carlos A

    2014-10-01

    The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures. © 2014 by the American College of Prosthodontists.

  17. Ecology of Candida-associated Denture Stomatitis

    OpenAIRE

    Budtz-Jørgensen, Ejvind

    2011-01-01

    Introduction of a prosthesis into the oral cavity results in profound alterations of the environmental conditions as the prosthesis and the underlying mucosa become colonized with oral microorganisms, including Candida spp. This may lead to denture stomatitis, a non-specific inflammatory reaction against microbial antigens, toxins and enzymes produced by the colonizing microorganisms. The role of Candida in the etiology of denture stomatitis is indicated by an increased number of yeasts on th...

  18. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    Science.gov (United States)

    Allen, Finbarr

    2010-01-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  19. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2011-03-15

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  20. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2010-10-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  1. Comparative evaluation of different mechanical modifications of denture teeth on bond strength between high-impact acrylic resin and denture teeth: An in vitro study.

    Science.gov (United States)

    Phukela, Sumit Singh; Chintalapudi, Siddesh Kumar; Sachdeva, Harleen; Dhall, Rupinder Singh; Sharma, Neeraj; Prabhu, Allama

    2016-01-01

    Acrylic teeth separates from the denture base and remains a major worry in day-to-day routine dental procedure. The present study was conducted to comparatively evaluate different mechanical modifications of acrylic teeth on bond strength between Lucitone 199 heat cure resin and cross-linked teeth. The test specimens, central incisors (21) were demarcated into four groups. Group 1 was the control group, whereas Group 2, Group 3, and Group 4 were experimental groups modified with round groove, vertical groove, and T-shaped groove, respectively. The preparation of masterpiece was done by aligning the long axis of the central incisor teeth at 45° to the base of a wax block (8 mm × 10 mm × 30 mm), with ridge lap surface contacting the base. These test specimen (21) was prepared by Lucitone 199 heat cure resin. Evaluation of bond strength of all the specimens was done using universal tester (materials testing machine). Shapiro-Wilk Test, one-way analysis of variance (ANOVA), and Bonferroni test were done to do statistical investigation. Group 1 specimens prepared by Lucitone 199 heat cure resin showed the lowest bond strength and Group 4 specimens prepared with T-shaped groove packed with Lucitone 199 exhibited the highest bond strength. The bond strength between Lucitone 199 heat cure resin and cross-linked teeth was increased when mechanical modifications was done on denture teeth. The specimens prepared with T-shaped groove packed with Lucitone 199 heat cure resin showed the highest bond strength followed by Group 3, Group 2, and lastly Group 1 prepared by Lucitone 199 heat cure resin.

  2. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Clinical evaluation of the essential oil of "Satureja Hortensis" for the treatment of denture stomatitis

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Sabzghabaee

    2012-01-01

    Full Text Available Background: The prevalence of denture stomatitis has been shown to vary from 15 to 65% in complete denture wearers. Satureja hortensis L. has been considered to have antinociceptive, anti-inflammatory, antifungal and antimicrobial activities in vitro and exhibits strong inhibitory effect on the growth of periodontal bacteria. The aim of this study was to evaluate the efficacy of a 1% gel formulation of S. hortensis essential oil for the treatment of denture stomatitis. Materials and Methods: A randomized, controlled clinical trial study was conducted on 80 patients (mean age 62.91±7.34 in two parallel groups treated either with S. hortensis essential oil 1% gel or placebo applied two times daily for two weeks. Denture stomatitis was diagnosed by clinical examination and paraclinical confirmation with sampling the palatal mucosa for Candida albicans. Data were analyzed using Chi-squared or Student′s t tests. Results: The erythematous lesions of palatal area were significantly reduced (P<0.0001 in the treatment group who applied 1% topical gel of S. hortensis essential oil and Candida colonies count were reduced significantly (P=0.001. Conclusion: Topical application of the essential oil of S. hortensis could be considered as an effective agent for the treatment of denture stomatitis.

  4. Does tooth loss have an emotional effect? A cross-sectional and comparative study on nondenture wearers and complete denture wearers

    Directory of Open Access Journals (Sweden)

    Md. Shakeel Anjum

    2017-01-01

    Full Text Available Introduction: Teeth play various functional and esthetic roles. As any part of the body, even teeth loss gives one the feeling of being handicapped showing a negative impact on emotions. Sometimes, few people think that having 32 teeth and losing a few among them will not make a difference. Aim: To assess and compare the emotional effects due to loss of natural teeth in complete denture wearers and nondenture wearers. Materials and Methods: A hospital-based survey was conducted on complete denture wearers and nondenture wearers who were attending the outpatient department in a dental hospital for 2 months using a pretested, self-administered questionnaire. Results: Among them who were surveyed, 65.75% agreed accepting the tooth loss is difficult, only 30.13% felt that loss of teeth affected their self-confidence (P = 0.094, about 80.82% reported that natural teeth loss affected their eating efficiency, and 57.53% of them found it difficult while speaking to others. There was a significant difference between denture wearers and nondenture wearers when asked whether loss of teeth affected their looks, eating efficiency, and speaking difficulties (P = 0.000. Conclusion: Even though the majority of them found it difficult in accepting tooth loss, it did not affect their self-confidence majorly; however, most of them found functional difficulties with loss of natural teeth.

  5. Colour stability of denture teeth submitted to different cleaning protocols and accelerated artificial aging.

    Science.gov (United States)

    Freire, T S; Aguilar, F G; Garcia, L da Fonseca Roberti; Pires-de-Souza, F de Carvalho Panzeri

    2014-03-01

    Acrylic resin is widely used for artificial teeth manufacturing due to several important characteristics; however, this material do not present acceptable colour stability over the course of time. This study evaluated the effect of different cleaning protocols and accelerated artificial aging on colour stability of denture teeth made of acrylic resin. Sixty denture teeth in dark and light shades were used, and separated according to the treatment to which they were submitted. Results demonstrated that colour stability of artificial teeth is influenced by the cleaning solution and artificial aging, being dark teeth more susceptible to colour alteration than lighter ones.

  6. Versatility of PEEK as a fixed partial denture framework.

    Science.gov (United States)

    Sinha, Nikita; Gupta, Nidhi; Reddy, K Mahendranadh; Shastry, Y M

    2017-01-01

    Materials used for fixed partial denture (FPD) frameworks have had properties of excellent strength, durability, and biocompatibility. Some of the materials which have been used till date include alloys, ceramics, and high-performance polymers such as zirconia, Ni-Cr, lithium disilicate, and so on. All these, though excellent, have their advantages and disadvantages. Hence, the search has always been on for a better material. One such material, which has made its foray into dentistry in the recent times, is polyetheretherketone (PEEK). It is a semicrystalline thermoplastic material. PEEK has an excellent chemical resistance and mechanical properties that are retained at high temperatures. The versatility of PEEK as a dental material for FPD framework was evaluated in this case report.

  7. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    Science.gov (United States)

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  8. Candida albicans importance to denture wearers. A literature review.

    Science.gov (United States)

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  9. Alveolar ridge rehabilitation to increase full denture retention and stability

    OpenAIRE

    Mefina Kuntjoro; Rostiny Rostiny; Wahjuni Widajati

    2010-01-01

    Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augme...

  10. Denture-related oral mucosal lesions among removable denture wearers ‎referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Shahrzad Taheri

    2016-05-01

    CONCLUSION: The finding of this study showed the prevalence of denture-related mucosal lesions is common. Dentists should be instruct the patients for removing the denture at night and routine follow-up visits.

  11. Cost-effectiveness of implant-supported mandibular removable partial dentures

    NARCIS (Netherlands)

    Jensen, Charlotte; Ross, Jamila; Feenstra, Talitha L; Raghoebar, Gerry M; Speksnijder, Caroline; Meijer, Henny J A; Cune, Marco S

    ObjectivesThe aim of this study was to conduct a cost-effectiveness analysis comparing conventional removable partial dentures (RPDs) and implant-supported RPDs (ISRPDs) treatment in patients with an edentulous maxilla and a bilateral free-ending situation in the mandible. Material and methodsThirty

  12. [Quantitative and qualitative analysis of oral microbiota by orthopedic rehabilitation with full and partial removable dentures].

    Science.gov (United States)

    Stafeev, A A; Chesnokova, M G; Chesnokov, V A

    2015-01-01

    Microbiological analysis of biomaterial surface in dental prosthesis showed the most common colonizing gram-positive species to be S. aureus, Micrococcus spp., S. haemolyticus, E. faecalis, mainly massive colonization with S. aureus was seen. The highest concentration of C. albicans colonization was found in removable dentures and may have a destructive effect on prosthetic material.

  13. 21 CFR 872.3580 - Preformed gold denture tooth.

    Science.gov (United States)

    2010-04-01

    ... tooth in a fixed or removable partial denture. (b) Classification. Class I (general controls). The... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a...

  14. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a water...

  15. Treatment Outcomes Based on Patients' Self-Reported Measures after Receiving New Clasp or Precision Attachment-Retained Removable Partial Dentures.

    Science.gov (United States)

    Peršić, Sanja; Kranjčić, Josip; Pavičić, Daniela Kovačević; Mikić, Vlatka Lajnert; Čelebić, Asja

    2017-02-01

    To evaluate effects of a treatment taking into consideration esthetics, chewing, and oral health-related quality of life (OHRQoL) of two tooth replacement strategies for maxillary partially edentulous patients with clasp (C-RPD) and precision attachment (PA-RPD) retained removable partial dentures (RPD). The study included 150 patients (72 men, 78 women) who received maxillary RPDs; 88 patients received clasp and 62 patients received precision attachment retained RPDs. Patients completed three questionnaires before treatment and again 3 months after treatment: the Orofacial Esthetic Scale (OES), the Oral Health Impact Profile (OHIP-14), and the Chewing Function Questionnaire (CFQ). Statistical analysis comprised descriptive statistics, paired t-test, and two-factor ANOVA. Both RPD treatments yielded better after-treatment summary scores when compared with the baseline scores (p < 0.01); however, better results were obtained in the PA-RPD group. Gender, as a single factor, did not yield significant effects; mutual interaction of retention type and gender yielded significant effects. The PA-RPD female group assessed esthetics, chewing function, and OHRQoL significantly better than males, and significantly worse than males in the C-RPD group. The covariate baseline scores yielded statistically significant effects; patients with worse pretreatment condition benefited more from both therapies. Treatment outcomes were better in the PA-RPD group than the C-RPDs. Women showed greater concern for the treatment outcomes; their rates were significantly better than in male patients in the PA-RPD group; however, when their satisfaction was lower, their rates were significantly worse than in male patients (in the C-RPD group). © 2015 by the American College of Prosthodontists.

  16. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    Science.gov (United States)

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  17. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface

    Directory of Open Access Journals (Sweden)

    Ana Paula Coelho Vieira

    2010-09-01

    Full Text Available This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min, 0.5% sodium hypochlorite (10 min or distilled water (control; 15 min. After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL. Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05. Results of cell count estimation showed significant differences in cleanliness among the treatments (p 0.05 was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p < 0.001. Sodium hypochlorite was the only treatment that removed biofilm efficiently, since no viable cells were found after its use. In conclusion, alkaline peroxide denture cleansers were not effective in removing Candida spp. biofilm from denture liner surfaces and preventing biofilm recolonization.

  18. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    Science.gov (United States)

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  19. [Study of the appearance difference of lower complete denture between functional and anatomic impression techniques].

    Science.gov (United States)

    Zhong, Qun; Wu, Xue-yin; Shen, Qing-yi; Shen, Qing-ping

    2012-04-01

    To compare the difference in oblique external ridge, oblique internal ridge and alveolar process crest of lower complete denture base made through functional impression and anatomic impression techniques. Fifteen patients were chosen to treat with two kinds of complete dentures through functional impression and anatomic impression technique respectively. 3D laser scanner was used to scan the three-dimensional model of the denture base and the differences of the surface structural between two techniques in alveolar process crest, external and internal oblique ridges were analyzed, using paired t test with SPSS 12.0 software package. Between the two techniques, there were significant differences in the areas of internal and external oblique ridge(P0.05). The results explain why there is less tenderness when functional impression technique is applied. The differences measured also indicate that sufficient buffering should be made in external and internal oblique ridge areas in clinic.

  20. Packaging based on polymeric materials

    Directory of Open Access Journals (Sweden)

    Jovanović Slobodan M.

    2005-01-01

    Full Text Available In the past two years the consumption of common in the developed countries world wide (high tonnage polymers for packaging has approached a value of 50 wt.%. In the same period more than 50% of the packaging units on the world market were made of polymeric materials despite the fact that polymeric materials present 17 wt.% of all packaging materials. The basic properties of polymeric materials and their environmental and economical advantages, providing them such a position among packaging materials, are presented in this article. Recycling methods, as well as the development trends of polymeric packaging materials are also presented.

  1. Vanadium based materials as electrode materials for high performance supercapacitors

    Science.gov (United States)

    Yan, Yan; Li, Bing; Guo, Wei; Pang, Huan; Xue, Huaiguo

    2016-10-01

    As a kind of supercapacitors, pseudocapacitors have attracted wide attention in recent years. The capacitance of the electrochemical capacitors based on pseudocapacitance arises mainly from redox reactions between electrolytes and active materials. These materials usually have several oxidation states for oxidation and reduction. Many research teams have focused on the development of an alternative material for electrochemical capacitors. Many transition metal oxides have been shown to be suitable as electrode materials of electrochemical capacitors. Among them, vanadium based materials are being developed for this purpose. Vanadium based materials are known as one of the best active materials for high power/energy density electrochemical capacitors due to its outstanding specific capacitance and long cycle life, high conductivity and good electrochemical reversibility. There are different kinds of synthetic methods such as sol-gel hydrothermal/solvothermal method, template method, electrospinning method, atomic layer deposition, and electrodeposition method that have been successfully applied to prepare vanadium based electrode materials. In our review, we give an overall summary and evaluation of the recent progress in the research of vanadium based materials for electrochemical capacitors that include synthesis methods, the electrochemical performances of the electrode materials and the devices.

  2. [Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology].

    Science.gov (United States)

    Deng, K H; Wang, Y; Chen, H; Zhao, Y J; Zhou, Y S; Sun, Y C

    2017-06-09

    Objective: To quantitatively evaluate the adaptation of polylactic acid (PLA) pattern of mandibular complete denture fabricated by fused deposition modeling (FDM) technology. Methods: A mandibular complete denture digital model was designed through a complete denture design software based on a pair of standard maxillomandibular edentulous plaster model and their occlusion bases. Ten PLA mandibular complete dentures were printed with a FDM machine. The dentures were scanned with and without the plaster model using a three-dimensional (3D) scanner. In Geomagic software, the scanning data of printed dentures were registered to its computer aided design (CAD) data, and the printing error was analyzed using the multipoint registration command. For quantitatively evaluating the adaptation of the denture, the data of plaster model and PLA denture were registered to the whole data of denture located in the plaster model using the best-fit alignment command, the 3D deviation of the plaster model and tissue surface of the denture represent the space between them. The overall area was separated into three parts: primary stress-bearing area, secondary stress-bearing area and border seal area, and the average deviations of these three parts were measured. The values were analyzed using analysis of variance. Results: Compared with the CAD data, the printing error was (0.013±0.004) mm. The overall 3D deviation between PLA denture and plaster model was (0.164±0.033) mm, in which the primary stress-bearing area was (0.165± 0.045) mm, the secondary stress-bearing area was (0.153 ± 0.027) mm, the border seal area was (0.186 ± 0.043) mm. These showed a good fit in the majority parts of the FDM denture to the plaster model. No statistically significant difference was observed between the three areas ( F =1.857, P =0.175>0.05). Conclusions: Combined with the 3D scanning, CAD and FDM technology, a FDM 3D printing process of complete denture for injection moulding can be established

  3. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Science.gov (United States)

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  4. Epidemiological Data and Survival Rate of Removable Partial Dentures

    Science.gov (United States)

    Moreno, Amália; Haddad, Marcela Filié; Rocha, Eduardo Passos; Assunção, Wirley Gonçalves; Filho, Humberto Gennari; Santos, Emerson Gomes Dos; Sonego, Mariana Vilela; Santos, Daniela Micheline Dos

    2016-01-01

    Introduction The use of removable partial denture (RPD) is considered as low-cost and common treatment option to rehabilitate edentulous areas. Aim This study aimed to investigate the epidemiological data of patients rehabilitated with removable partial denture (RPD) in order to assess treatment survival rate and failures. Materials and Methods Epidemiological data and medical records of patients treated with RPD between 2007 and 2012 at the RPD discipline of a Brazilian University (Aracatuba Dental School- UNESP) were evaluated as well as dental records of patients who underwent RPD treatments (fabrication or repairs) between 2000 and 2010. Factors such as gender, age, presence of systemic disease, main complaint, edentulous arch, period and cause of denture replacement and the prosthesis characteristics were recorded. The chi-square test was used to assess the differences between the variables and the Kaplan Meyer to assess the survival of the RPDs evaluated. Results A total of 324 maxillary RPD and 432 mandibular RPD were fabricated. Most of the patients were women aging 41 to 60-year-old. The number of mandibular RPD Kennedy class I (26%) was statistically higher for the maxillary arch (p<.05). There was no association between main complaint to gender or the presence of systemic disease. The lingual plate was the most common major connector used in the mandible (32%). The main reason for altering the design of replaced RPDs were changes during treatment plan. Conclusion The number of patients who require RPD is large; most of RPDs are Kennedy Class I. A good treatment plan is very important for achieving a positive treatment outcome, and it is strictly related to the survival rate. PMID:27437367

  5. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    Science.gov (United States)

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of

  6. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    Science.gov (United States)

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies. PMID:27223294

  7. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    Science.gov (United States)

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  8. Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2015-01-01

    Full Text Available Background: The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. Methods: Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC, lateral incisor (IL, canine (Ca, first premolar (P1, second premolar (P2, first molar (M1, and second molar (M2 regions. The thickness was measured in the alveolar ridge crest (T, buccal (B1-B4, and lingual (L1-L4 alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B and lingual sides (L were also assessed. Results: The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01. On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01, and was thicker than IC, IL, P1, and P2 at B2. Conclusions: Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.

  9. Knowledge-based metals & materials

    OpenAIRE

    Sasson, Amir

    2011-01-01

    This study presents the Norwegian metal and material industry (defined as all metal and material related firms located in Norway, regardless of ownership) and evaluates the industry according to the underlying dimensions of a global knowledge hub - cluster attractiveness, education attractiveness, talent attractiveness, R&D and innovation attractiveness, ownership attractiveness, environmental attractiveness and cluster dynamics.

  10. [A phd completed 10. Implant-supported removable partial -dentures in a Kennedy Class I-situation in the mandible].

    Science.gov (United States)

    Jensen-Louwerse, C

    2017-06-01

    Implant-supported removable partial dentures in the mandible often cause problems, which means that patients wear their dentures seldom if at all. A solution is to place implants that the dentures can be snapped onto. There is, however, no consensus about the best position of the implants in the mandible yet. In addition, it is worthwhile to balance the cost of treatment with its effectiveness. In a randomised cross-over clinical trial involving 30 patients with a shortened dental arch, the implant-supported removable partial denture in the mandible was evaluated based on the experience of the patient, mean time of wearing, chewing ability and the clinical and radiographic parameters in relation to 2 different implant positions: 2 in the pre-molar region or 2 in the molar region. The cost-effectiveness of both treatments was also evaluated. From the patient's point of view, the implant-supported removable partial dentures are best supported by implants placed in the molar region. The research also revealed, however, that significantly more bleeding occurred around implants placed in the molar region and from a clinical perspective placement in the pre-molar region would have preference. The cost-effectiveness of the treatment with an implant-supported removable partial denture depends on the choice of outcome measurement and monetary threshold.

  11. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    Science.gov (United States)

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  12. [Elderly people and removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de

    2009-01-01

    The most frequently reported disadvantages of removable partial dentures are the more demanding daily oral hygiene self-care, especially for people who already experience difficulties in self-care, and the possible harmful influence on the remaining dentition. These disadvantages can be expressed in

  13. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  14. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  15. The impact of complete denture making instructional videos on self-directed learning of clinical skills.

    Science.gov (United States)

    Kon, Haruka; Botelho, Michael George; Bridges, Susan; Leung, Katherine Chiu Man

    2015-04-01

    The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. 47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical complete denture procedures. After completion, students evaluated their learning experience, and 11 students participated in focus group interviews to gain further insight. A mixed-methods approach to data collection and analysis provided descriptive statistical results and a grounded theory approach to coding identified key concepts and categories from the qualitative data. Over 70% of students had favorable opinions of the learning experience and indicated that the speed and length of the video were appropriate. Highly positive and conflicting negative comments regarding the use of subtitles showed both preferences for subtitles over audio and vice versa. The use of a video resource was considered valuable as the replay and review functions allowed better visualization of the procedures, which was considered a good recap tool for the clinical demonstration. It was also a better revision aid than textbooks. So, if the students were able to view these videos at will, they believed that videos supplemented their self-study. Despite the positive response, videos were not considered to replace live clinical demonstrations. While students preferred live demonstrations over the clinical videos they did express a realization of these as a supplemental learning material for self-study based on their ease of access, use for revision, and prior to clinical preparation. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  16. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    Science.gov (United States)

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  17. Development of starch-based materials

    NARCIS (Netherlands)

    Habeych Narvaez, E.A.

    2009-01-01

    Starch-based materials show potential as fully degradable plastics. However, the current
    applicability of these materials is limited due to their poor moisture tolerance and
    mechanical properties. Starch is therefore frequently blended with other polymers to make
    the material more

  18. Melanin-Based Functional Materials

    Directory of Open Access Journals (Sweden)

    Marco d’Ischia

    2018-01-01

    Full Text Available Melanin biopolymers are currently the focus of growing interest for a broad range of applications at the cutting edge of biomedical research and technology. This Special Issue presents a collection of papers dealing with melanin-type materials, e.g., polydopamine, for classic and innovative applications, offering a stimulating perspective of current trends in the field. Besides basic scientists, the Special Issue is directed to researchers from industries and companies that are willing to invest in melanin research for innovative and inspiring solutions.

  19. Materiality in a practice-based approach

    DEFF Research Database (Denmark)

    Svabo, Connie

    2009-01-01

    The paper provides an overview of the vocabulary for materiality which is used by practice-based approaches to organizational knowing. Common terms for materiality are 'artifact' and 'object'. The interaction between social and material realities is grasped as several processes: object......-oriented activity, symbolization, embodiment, performance, alignment and mediation. Material artifacts both stabilize and destabilize organizational action. They may ensure coordination, communication, and control, but they may also create disturbance and conflict....

  20. A Randomized Controlled Trial of Mastication with Complete Dentures Made by a Conventional or an Abbreviated Technique.

    Science.gov (United States)

    Mengatto, Cristiane Machado; Gameiro, Gustavo Hauber; Brondani, Mario; Owen, C Peter; MacEntee, Michael I

    The aim of this randomized clinical trial was to test the hypothesis that there are no statistically significant differences after 3 and 6 months in masticatory performance or chewing ability of people with new complete dentures made by an abbreviated or a conventional technique. The trial included 20 edentulous participants at a dental school in Brazil assigned randomly to receive dentures made by either a conventional technique involving six clinical sessions or by an abbreviated technique involving three clinical sessions. At baseline with old dentures and at 3 and 6 months with new dentures, masticatory performance was measured by counting the number of chewing strokes and the time before participants had an urge to swallow and by calculating the medium particle size of a silicone material after 20 chewing strokes and at the urge to swallow. On each occasion, the participants recorded on visual analog scales their ability to chew five food textures. Statistical significance (P ≤ .05) of changes in masticatory performance and chewing ability during the trial were analyzed with generalized estimating equations. Both techniques improved masticatory performance between baseline and 6 months and the ability to bite and chew all foods apart from hard apples. There were no significant differences in masticatory performance or chewing ability after 6 months between complete dentures made by a conventional or an abbreviated technique.

  1. Denture acceptance among newly rehabilitated elderly population in old age homes in South India

    Directory of Open Access Journals (Sweden)

    Mallika S Shetty

    2015-01-01

    Full Text Available Introduction: Elders in old age homes are mainly those who have been abandoned by their family and have one or more physical or mental disabilities. It is a major challenge for the dental professional to plan oral health strategy for this group of patients. Aim of the Study: Aim of the present study is to observe and determine the acceptance of new dental prosthesis among the elderly residing as inmates of 3 old age homes in Mangalore City. Materials and Methods: This cross-sectional study was conducted using a survey proforma. Information regarding their experience with the new denture, 1-month, 3 months and 6 months after denture insertion was gathered. Statistical analysis of the data was done using the Chi-square test with the P < 0.05 considered significant. Results: One hundred and eighty-three residents out of a total of 400 residents in 3 old age homes were denture wearers. Among them, 101 (55.2% were females, and 82 (44.8% were males. Dental prosthesis whether worn regularly, discomfort, retention, cleansing of denture during a period of 1-month, 3 months and 6 months was found to be significant satisfaction with the prosthesis, denture adhesives used, food accumulation during a period of 1-month, 3 months and 6 months was found to be nonsignificant. Conclusion: The emotional makeup of the patient must be taken into consideration during the entire procedure. We must understand that the success of the prosthesis depends mainly on the patient′s confidence in the dentist rather than the quality of the prosthesis.

  2. Oral Crest Lengthening for Increasing Removable Denture Retention by Means of CO2 Laser

    Directory of Open Access Journals (Sweden)

    Samir Nammour

    2014-01-01

    Full Text Available The loss of teeth and their replacement by artificial denture is associated with many problems. The denture needs a certain amount of ridge height to give it retention and a long-term function. Crest lengthening procedures are performed to provide a better anatomic environment and to create proper supporting structures for more stability and retention of the denture. The purpose of our study is to describe and evaluate the effectiveness of CO2 laser-assisted surgery in patients treated for crest lengthening (vestibular deepening. There have been various surgical techniques described in order to restore alveolar ridge height by pushing muscles attaching of the jaws. Most of these techniques cause postoperative complications such as edemas, hemorrhage, pain, infection, slow healing, and rebound to initial position. Our clinical study describes the treatment planning and clinical steps for the crest lengthening with the use of CO2 laser beam (6–15 Watts in noncontact, energy density range: 84.92–212.31 J/cm2, focus, and continuous mode with a focal point diameter of 0.3 mm. At the end of each surgery, dentures were temporarily relined with a soft material. Patients were asked to mandatorily wear their relined denture for a minimum of 4–6 weeks and to remove it for hygienic purposes. At the end of each surgery, the deepest length of the vestibule was measured by the operator. No sutures were made and bloodless wounds healed in second intention without grafts. Results pointed out the efficiency of the procedure using CO2 laser. At 8 weeks of post-op, the mean of crest lengthening was stable without rebound. Only a loss of 15% was noticed. To conclude, the use of CO2 laser is an effective option for crest lengthening.

  3. LDEF materials special investigation group's data bases

    Science.gov (United States)

    Strickland, John W.; Funk, Joan G.; Davis, John M.

    1993-01-01

    The Long Duration Exposure Facility (LDEF) was composed of and contained a wide array of materials, representing the largest collection of materials flown for space exposure and returned for ground-based analyses to date. The results and implications of the data from these materials are the foundation on which future space missions will be built. The LDEF Materials Special Investigation Group (MSIG) has been tasked with establishing and developing data bases to document these materials and their performance to assure not only that the data are archived for future generations but also that the data are available to the space user community in an easily accessed, user-friendly form. The format and content of the data bases developed or being developed to accomplish this task are discussed. The hardware and software requirements for each of the three data bases are discussed along with current availability of the data bases.

  4. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    Science.gov (United States)

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  5. Elderly complete denture wearers: a social approach to tooth loss.

    Science.gov (United States)

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  6. EPR-based material modelling of soils

    Science.gov (United States)

    Faramarzi, Asaad; Alani, Amir M.

    2013-04-01

    In the past few decades, as a result of the rapid developments in computational software and hardware, alternative computer aided pattern recognition approaches have been introduced to modelling many engineering problems, including constitutive modelling of materials. The main idea behind pattern recognition systems is that they learn adaptively from experience and extract various discriminants, each appropriate for its purpose. In this work an approach is presented for developing material models for soils based on evolutionary polynomial regression (EPR). EPR is a recently developed hybrid data mining technique that searches for structured mathematical equations (representing the behaviour of a system) using genetic algorithm and the least squares method. Stress-strain data from triaxial tests are used to train and develop EPR-based material models for soil. The developed models are compared with some of the well-known conventional material models and it is shown that EPR-based models can provide a better prediction for the behaviour of soils. The main benefits of using EPR-based material models are that it provides a unified approach to constitutive modelling of all materials (i.e., all aspects of material behaviour can be implemented within a unified environment of an EPR model); it does not require any arbitrary choice of constitutive (mathematical) models. In EPR-based material models there are no material parameters to be identified. As the model is trained directly from experimental data therefore, EPR-based material models are the shortest route from experimental research (data) to numerical modelling. Another advantage of EPR-based constitutive model is that as more experimental data become available, the quality of the EPR prediction can be improved by learning from the additional data, and therefore, the EPR model can become more effective and robust. The developed EPR-based material models can be incorporated in finite element (FE) analysis.

  7. Present status of titanium removable dentures--a review of the literature.

    Science.gov (United States)

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  8. Diamond-based materials for biomedical applications

    CERN Document Server

    Narayan, Roger

    2013-01-01

    Carbon is light-weight, strong, conductive and able to mimic natural materials within the body, making it ideal for many uses within biomedicine. Consequently a great deal of research and funding is being put into this interesting material with a view to increasing the variety of medical applications for which it is suitable. Diamond-based materials for biomedical applications presents readers with the fundamental principles and novel applications of this versatile material. Part one provides a clear introduction to diamond based materials for medical applications. Functionalization of diamond particles and surfaces is discussed, followed by biotribology and biological behaviour of nanocrystalline diamond coatings, and blood compatibility of diamond-like carbon coatings. Part two then goes on to review biomedical applications of diamond based materials, beginning with nanostructured diamond coatings for orthopaedic applications. Topics explored include ultrananocrystalline diamond for neural and ophthalmologi...

  9. New Cork-Based Materials and Applications

    Directory of Open Access Journals (Sweden)

    Luís Gil

    2015-02-01

    Full Text Available This review work is an update of a previous work reporting the new cork based materials and new applications of cork based materials. Cork is a material which has been used for multiple applications. The most known uses of cork are in stoppers (natural and agglomerated cork for alcoholic beverages, classic floor covering with composite cork tiles (made by the binding of cork particles with different binders, and thermal/acoustic/vibration insulation with expanded corkboard in buildings and some other industrial fields. Many recent developments have been made leading to new cork based materials. Most of these newly developed cork materials are not yet on the market, but they represent new possibilities for engineers, architects, designers and other professionals which must be known and considered, potentially leading to their industrialization. This paper is a review covering the last five years of innovative cork materials and applications also mentioning previous work not reported before.

  10. New Cork-Based Materials and Applications

    Science.gov (United States)

    Gil, Luís

    2015-01-01

    This review work is an update of a previous work reporting the new cork based materials and new applications of cork based materials. Cork is a material which has been used for multiple applications. The most known uses of cork are in stoppers (natural and agglomerated cork) for alcoholic beverages, classic floor covering with composite cork tiles (made by the binding of cork particles with different binders), and thermal/acoustic/vibration insulation with expanded corkboard in buildings and some other industrial fields. Many recent developments have been made leading to new cork based materials. Most of these newly developed cork materials are not yet on the market, but they represent new possibilities for engineers, architects, designers and other professionals which must be known and considered, potentially leading to their industrialization. This paper is a review covering the last five years of innovative cork materials and applications also mentioning previous work not reported before. PMID:28787962

  11. New Cork-Based Materials and Applications.

    Science.gov (United States)

    Gil, Luís

    2015-02-10

    This review work is an update of a previous work reporting the new cork based materials and new applications of cork based materials. Cork is a material which has been used for multiple applications. The most known uses of cork are in stoppers (natural and agglomerated cork) for alcoholic beverages, classic floor covering with composite cork tiles (made by the binding of cork particles with different binders), and thermal/acoustic/vibration insulation with expanded corkboard in buildings and some other industrial fields. Many recent developments have been made leading to new cork based materials. Most of these newly developed cork materials are not yet on the market, but they represent new possibilities for engineers, architects, designers and other professionals which must be known and considered, potentially leading to their industrialization. This paper is a review covering the last five years of innovative cork materials and applications also mentioning previous work not reported before.

  12. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  13. Esthetic double-structure fixed partial dentures.

    Science.gov (United States)

    Ravasini, G; Ugolini, G; Ravasini, F

    1996-04-01

    A new technical procedure for fixed partial dentures and single inlays allows the use of a metal supporting structure with independent ceramic coverage. The advantages of the technique are the bonding of metal to beveled dentinal margins with conventional cement and the acid-etched resin composite cementation of the ceramic, which permits more conservative preparation of the teeth. The complexity of the structure, the laboratory costs, and the doubling of the cementation procedures are the main disadvantages of the technique.

  14. Telescopic Partial Dentures-Concealed Technology

    OpenAIRE

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-01-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of ?floating plastic? in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental impl...

  15. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    Science.gov (United States)

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  16. Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study

    Directory of Open Access Journals (Sweden)

    Duggineni Chalapathi Rao

    2015-01-01

    Results: Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.

  17. Membrane-based biomolecular smart materials

    International Nuclear Information System (INIS)

    Sarles, Stephen A; Leo, Donald J

    2011-01-01

    Membrane-based biomolecular materials are a new class of smart material that feature networks of artificial lipid bilayers contained within durable synthetic substrates. Bilayers contained within this modular material platform provide an environment that can be tailored to host an enormous diversity of functional biomolecules, where the functionality of the global material system depends on the type(s) and organization(s) of the biomolecules that are chosen. In this paper, we review a series of biomolecular material platforms developed recently within the Leo Group at Virginia Tech and we discuss several novel coupling mechanisms provided by these hybrid material systems. The platforms developed demonstrate that the functions of biomolecules and the properties of synthetic materials can be combined to operate in concert, and the examples provided demonstrate how the formation and properties of a lipid bilayer can respond to a variety of stimuli including mechanical forces and electric fields

  18. Characterization of asphalt treated base course material

    Science.gov (United States)

    2010-06-01

    Asphalt-treated bases are often used in new pavements; the materials are available and low-cost, but there is little data on how these materials perform in cold regions. : This study investigated four ATB types (hot asphalt, emulsion, foamed asphalt,...

  19. [Occlusal schemes of complete dentures--a review of the literature].

    Science.gov (United States)

    Tarazi, E; Ticotsky-Zadok, N

    2007-01-01

    Occlusal scheme is defined as the form and the arrangement of the occlusal contacts in natural and artificial dentition. The choice of an occlusal scheme will determine the pattern of occlusal contacts between opposing teeth during centric relation and functional movement of the mandible. With dentures, the quantity and the intensity of these contacts determine the amount and the direction of the forces that are transmitted through the bases of the denture to the residual ridges. That is why the occlusal scheme is an important factor in the design of complete dentures. Three occlusal schemes are viewed in this review: bilateral balanced occlusion, monplane occlusion, and linear occlusion scheme. Each scheme represents a different concept of occlusion. Comparisons between these schemes are also reviewed and analyzed. The reasoning underlying the bilateral balanced occlusion scheme is that stability of the dentures is attained when bilateral contacts exist throughout all dynamic and static states of the denture during function. Anatomic teeth are used: the upper anterior teeth are set to satisfy aesthetics, and the posterior teeth are arranged in a compensatory curve and a medial curve. This scheme is adequate for well developed residual ridges, with skeletal class I relation. With highly resorbed residual ridges, the vectors of force that are transmitted through anatomic cusps will dislodge the lower denture and thus impair the comfort and efficiency of mastication experienced by the patient. In order to accommodate to the special needs posed by highly resorbed residual ridges and skeletal relations that are not class I, the monoplane scheme of occlusion was designed. This scheme consists of non anatomic (cuspless) teeth, which are set so that the anterior teeth provide the aesthetics, the premolars and the first molars are used for chewing, and the second molars do not occlude (although sometimes they are specifically used to establish bilateral contacts in lateral

  20. Materiality in a Practice-Based Approach

    Science.gov (United States)

    Svabo, Connie

    2009-01-01

    Purpose: The paper aims to provide an overview of the vocabulary for materiality which is used by practice-based approaches to organizational knowing. Design/methodology/approach: The overview is theoretically generated and is based on the anthology Knowing in Organizations: A Practice-based Approach edited by Nicolini, Gherardi and Yanow. The…

  1. A composite material based on recycled tires

    Science.gov (United States)

    Malers, L.; Plesuma, R.; Locmele, L.

    2009-01-01

    The present study is devoted to the elaboration and investigation of a composite material based on mechanically grinded recycled tires and a polymer binder. The correlation between the content of the binder, some technological parameters, and material properties of the composite was clarified. The apparent density, the compressive stress at a 10% strain, the compressive elastic modulus in static and cyclic loadings, and the insulating properties (acoustic and thermal) were the parameters of special interest of the present investigation. It is found that a purposeful variation of material composition and some technological parameters leads to multifunctional composite materials with different and predictable mechanical and insulation properties.

  2. Whole Language-Based English Reading Materials

    Directory of Open Access Journals (Sweden)

    Dian Erlina

    2016-05-01

    Full Text Available This Research and Development (R&D aims at developing English reading materials for undergraduate EFL students of Universitas Islam Negeri (UIN Raden Fatah Palembang, Indonesia. Research data were obtained through questionnaires, tests, and documents. The results of the research show that the existing materials are not relevant to the students’ need, so there is a need for developing new materials based on whole language principles. In general, the new developed materials are considered reliable by the experts, students, and lecturers. The materials are also effective in improving students’ reading achievement. The final product of the materials consists of a course book entitled Whole Language Reading (WLR and a teacher’s manual. WLR provides rich input of reading strategies, variety of topics, concepts, texts, activities, tasks, and evaluations. Using this book makes reading more holistic and meaningful as it provides integration across language skills and subject areas.

  3. Nanocellulose based polymer composite for acoustical materials

    Science.gov (United States)

    Farid, Mohammad; Purniawan, Agung; Susanti, Diah; Priyono, Slamet; Ardhyananta, Hosta; Rahmasita, Mutia E.

    2018-04-01

    Natural fibers are biodegradable materials that are innovatively and widely used for composite reinforcement in automotive components. Nanocellulose derived from natural fibers oil palm empty bunches have properties that are remarkable for use as a composite reinforcement. However, there have not been many investigations related to the use of nanocellulose-based composites for wideband sound absorption materials. The specimens of nanocellulose-based polyester composite were prepared using a spray method. An impedance tube method was used to measure the sound absorption coefficient of this composite material. To reveal the characteristics of the nanocellulose-based polyester composite material, SEM (scanning electron microscope), TEM (Transmission Electron Microscope), FTIR (Fourier Transform Infra Red), TGA (Thermogravimetric Analysis), and density tests were performed. Sound absorption test results showed the average value of sound absorption coefficient of 0.36 to 0,46 for frequency between 500 and 4000 Hz indicating that this nanocellulose-based polyester composite materials had a tendency to wideband sound absorption materials and potentially used as automotive interior materials.

  4. Expectations and satisfaction of denture patients in a university clinic.

    Science.gov (United States)

    Davis, E L; Albino, J E; Tedesco, L A; Portenoy, B S; Ortman, L F

    1986-01-01

    These results indicate that patients' expectations of dentures before treatment were unrealistically high and that informational videotapes did not significantly affect these expectations. Satisfaction with current dentures was surprisingly high before treatment and increased significantly from pretreatment to postreatment for both groups in the study. While it is likely that this increase in satisfaction reflects a change from poor to excellent denture status, this finding may also be attributed to cognitive dissonance theory; that is, high satisfaction may represent the means by which patients justify the expenses of their denture treatment. Although the videotape presentations did not alter the expectations of patients and their satisfaction with dentures, the tapes represent a potential source of accurate, standardized information for both patient and student dentist.

  5. Removable partial denture on osseointegrated implants and natural teeth.

    Science.gov (United States)

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  6. Precious-metal-base advanced materials

    International Nuclear Information System (INIS)

    Nowicki, T.; Carbonnaux, C.

    1993-01-01

    Precious metals constitute also the base of several advanced materials used in the industry in hundreds of metric tons. Platinum alloys have been used as structural materials for equipments in the glass industry. The essential reason for this is the excellent resistance of platinum alloys to oxidation and electrolytical corrosion in molten glasses at temperatures as high as 1200-1500 C. The major drawback is a weak creep resistance. The unique way for significant improvement of platinum base materials creep resistance is a strengthening by an oxide dispersion (ODS). In the case of CLAL's patented ''Plativer'' materials, 0.05 wt% of Y 2 O 3 is incorporated within the alloy matrix by the flame spraying process. Further improvement of platinum base materials is related, in the authors opinion, to the development of precious metals base intermetallics. Another interesting applications of precious metals are silver base electrical contacts. They are in fact silver matrix composites containing varying amounts of well-dispersed particles of constituents such as CdO, SnO 2 , Ni, WC or C. In the case of such materials, particular properties are required and tested : resistance to arc erosion, resistance to welding and contact resistance. Many other technically fascinating precious metals base materials exist: brazing alloys for assembling metals, superconductors and ceramics; dental materials including magnetic biocompatible alloys; silver composites for superconductor wire jackets. The observation of current evolution indicates very clearly that precious metals cannot be replaced by common metals because of their unique characteristics due to their atomic level properties

  7. Influence of adaptation of removable partial denture on masticatory performance.

    Directory of Open Access Journals (Sweden)

    Jorge Nakouzi

    2016-11-01

    Full Text Available Objective: To compare the masticatory performance (MP of patients with old removable partial denture (RPD, recently inserted RPD and already adapted RPD by means of the simple sieve test. Material and Methods: Twenty-nine adult (>18 years old volunteer patients were recruited, with lower and upper RPD, excluding total edentulous subjects in the upper and lower jaw, with temporomandibular disorders, severe periodontal disease, mental disability or systemic disease compromising the masticatory or nervous system. Dentures were designed and fabricated by an expert operator. MP was evaluated in old RPD (MP1, recently inserted RPD (MP2 and adapted RPD (MP3. The simple sieve test used was Edlund-Lamm in percentage of MP, using Optosil® Comfort condensation silicone tablets, with standard sizes (5.0x20mm. In each phase, the patient chewed the tablet with 20 masticatory strokes. The crushed fragments were dried at 80°C for 60 minutes and weighed on an analytical scale. A multiple vibration sieve analysis was performed, using sieves with opening sizes of 2.8mm and 1.4mm. Shapiro-Wilk test and Anova test with Bonferroni correction were performed. Results: It was observed that MP1 presented a mean of 8.40% (SD±5.59, MP2 a mean of 8.56% (SD±5.56, and MP3 a mean of 18.26% (SD±8.12. There was a significant difference (p<0.05 between the MP1-MP3 groups, as well as between the MP2-MP3 (p<0.05. Conclusion: There is a significant increase in MP thirty days after the insertion of RPD, checkups, and adjustments performed by the dentist.

  8. Evaluation of glass transition temperature and dynamic mechanical properties of autopolymerized hard direct denture reline resins.

    Science.gov (United States)

    Takase, Kazuma; Watanabe, Ikuya; Kurogi, Tadafumi; Murata, Hiroshi

    2015-01-01

    This study assessed methods for evaluation of glass transition temperature (Tg) of autopolymerized hard direct denture reline resins using dynamic mechanical analysis and differential scanning calorimetry in addition to the dynamic mechanical properties. The Tg values of 3 different reline resins were determined using a dynamic viscoelastometer and differential scanning calorimeter, and rheological parameters were also determined. Although all materials exhibited higher storage modulus and loss modulus values, and a lower loss tangent at 37˚C with a higher frequency, the frequency dependence was not large. Tg values obtained by dynamic mechanical analysis were higher than those by differential scanning calorimetry and higher frequency led to higher Tg, while more stable Tg values were also obtained by that method. These results suggest that dynamic mechanical analysis is more advantageous for characterization of autopolymerized hard direct denture reline resins than differential scanning calorimetry.

  9. Candida albicans biofilms and MMA surface treatment influence the adhesion of soft denture liners to PMMA resin

    Directory of Open Access Journals (Sweden)

    Martinna de Mendonça e Bertolini

    2014-01-01

    Full Text Available The effect of Candida albicans biofilms and methyl methacrylate (MMA pretreatment on the bond strength between soft denture liners and polymethyl methacrylate (PMMA resin was analyzed. Specimens were prepared and randomly divided with respect to PMMA pretreatment, soft liner type (silicone-based or PMMA-based, and presence or absence of a C. albicans biofilm. Samples were composed of a soft denture liner bonded between two PMMA bars. Specimens (n = 10 were incubated to produce a C. albicans biofilm or stored in sterile PBS for 12 days. The tensile bond strength test was performed and failure type was determined using a stereomicroscope. Surface roughness (SR and scanning electron microscopy (SEM analysis were performed on denture liners (n = 8. Highest bond strength was observed in samples containing a silicone-based soft liner and stored in PBS, regardless of pretreatment (p < 0.01. Silicone-based specimens mostly underwent adhesive failures, while samples containing PMMA-based liners predominantly underwent cohesive failures. The silicone-based specimens SR decreased after 12 days of biofilm accumulation or PBS storage, while the SR of PMMA-based soft liners increased (p < 0.01. The PMMA-based soft liners surfaces presented sharp valleys and depressions, while silicone-based specimens surfaces exhibited more gentle features. In vitro exposure to C. albicans biofilms reduced the adhesion of denture liners to PMMA resin, and MMA pretreatment is recommended during relining procedures.

  10. The influence of double flask investing on tooth displacement in dentures processed by microwave irradiation.

    Science.gov (United States)

    Farias Neto, Arcelino; Sousa, Rodrigo L dos Santos; Rizzatti-Barbosa, Célia M

    2012-06-01

    This study evaluated the influence of the bimaxillary flask (BMF) and two different investing materials on first molar inclination in dentures processed by microwave irradiation. The BMF may minimise tooth displacement, saving time and improving occlusion. Forty pairs of dentures were randomised into four groups: stone wall in monomaxillary flask; silicone wall in BMF; stone wall in BMF; acrylic resin retentions and silicone in BMF. Dentures were processed by microwave irradiation. Two referential points were established on tooth surface. A microscope and a digital pachymeter were used to measure the distance between these points, and the angles α (right maxillary molar), β (left maxillary molar), α' (right mandibular molar) and β' (left mandibular molar) were calculated by the law of cosines. Data were submitted to Kruskal-Wallis (5% significance). No difference was observed among the groups (p > 0.05). In the intra-group analysis, α was significantly different for groups I, II and III; α', for groups II and IV; β, for all groups; β', for groups III and IV. First molar inclination was similar for monomaxillary and BMFs. The use of stone or silicone as investing materials presented the same effect on tooth inclination. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  11. Use of training dentures in management of gagging

    Directory of Open Access Journals (Sweden)

    Shweta Yadav

    2011-01-01

    Full Text Available Gagging is a frequent impediment to the performance of dental procedures. This stimulation of the gagging reflex, or more accurately, the vomiting reflex, is a special problem in prosthodontic service. A hypersensitive gagging reflex often prevents the dentist from carrying out critical procedures or causes them to performat a less than satisfactory level. In addition, once having suffered an unpleasant gagging experience in a dentist′s office, the patients develop a fear of further visits to dentists. The purpose of this paper is to describe methods of managing the gagging patient that has a sound rationale based on modified treatment approaches starting from impression making to design of the prosthesis aided by training dentures to help the patient to tolerate prosthesis in mouth before fabrication of definite prosthesis.

  12. MICROECOLOGY OF THE MUCOUS MEMBRANE OF THE ALVEOLAR RIDGES IN THE PERIOD OF ADAPTATION TO COMPLETE DENTURES

    Directory of Open Access Journals (Sweden)

    Yanishen I. V.,

    2016-06-01

    Full Text Available Introduction. The oral cavity is an open ecosystem for various microorganisms and is one of the most populated biotopes of human. Removable dental prosthesis creates favorable conditions for the breeding of various microorganisms, including fungi. Stomatitis of dentition (SOD refers to a group of the most frequent pathologies of the mucous membranes of the oral cavity inflammatory character, due to the presence of the patient's dental prosthesis. For the prevention of SOD due to removable prostheses are used proper hygiene of dental prostheses, manufacture of technologically optimal designs of dentures, the shielding of the prosthesis and the use of cushioning materials. In this regard, the aim of this work was to study the dynamics characteristics of the microbiota of the mucous membranes of the oral cavity when performing prosthetic rehabilitation of patients with complete removable acrylic dentures with the use of adhesive and without its use. Materials and methods. The formation of the clinical groups of the patients occurred according to the following criteria: the study group comprised 23 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, which used water-resistant adhesive based on polyvinylacetate and carboxymethilcellulose (cushions and/or cream "Fittydent" according to the instructions of the manufacturer, the control group consisted of 12 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, in the period of adaptation to removable dentures has not applied the adhesive to improve the fixation of dentures. Microbiological examination of patients was carried out in dynamics before developing the prosthesis, after a week and after a month's stay of the prosthesis in the oral cavity. Results and discussion. Microbiological studies included determination of the qualitative and

  13. Triarylborane-Based Materials for OLED Applications

    Directory of Open Access Journals (Sweden)

    Gulsen Turkoglu

    2017-09-01

    Full Text Available Multidisciplinary research on organic fluorescent molecules has been attracting great interest owing to their potential applications in biomedical and material sciences. In recent years, electron deficient systems have been increasingly incorporated into fluorescent materials. Triarylboranes with the empty p orbital of their boron centres are electron deficient and can be used as strong electron acceptors in conjugated organic fluorescent materials. Moreover, their applications in optoelectronic devices, energy harvesting materials and anion sensing, due to their natural Lewis acidity and remarkable solid-state fluorescence properties, have also been investigated. Furthermore, fluorescent triarylborane-based materials have been commonly utilized as emitters and electron transporters in organic light emitting diode (OLED applications. In this review, triarylborane-based small molecules and polymers will be surveyed, covering their structure-property relationships, intramolecular charge transfer properties and solid-state fluorescence quantum yields as functional emissive materials in OLEDs. Also, the importance of the boron atom in triarylborane compounds is emphasized to address the key issues of both fluorescent emitters and their host materials for the construction of high-performance OLEDs.

  14. Telescopic Partial Dentures-Concealed Technology.

    Science.gov (United States)

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-09-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of "floating plastic" in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental implants or fixed partial denture is the better options, but they have certain limitations. However, overdentures and particularly telescopic denture is the overlooked technology in dentistry that would be a boon for such needy patients. Telescopic denture is especially indicated in the distal edentulous area with minimum two teeth bilaterally present with a good amount of periodontal support. This treatment modality is sort of preventive prosthodontics remedy, which in a conservative manner preserve the remaining teeth and helps in conservation of alveolar bone ultimately. There are two tenets related to this option, one is constant conservation edentulous ridge around the retained tooth and the most important is the endless existence of periodontal sensory action that directs and monitor gnathodynamic task. In this option the primary coping or inner coping are cemented on the prepared tooth, and a similar removable outer or inner telescopic crown placed tightly by using a mechanism of tenso-friction, this is firmly attached to a removable RPD in place without moving or rocking of the prosthesis, which is the common compliant of almost all patients of RPD. Copings are also protecting the abutment from tooth decay and also offers stabilization and maintaining of the outer crown. The outer crown engages the inner coping and gives as an anchor for the remainder of the dentition. This work is the review of telescopic prosthesis which is well supported by the case discussion, and

  15. Tungsten - Yttrium Based Nuclear Structural Materials

    Science.gov (United States)

    Ramana, Chintalapalle; Chessa, Jack; Martinenz, Gustavo

    2013-04-01

    The challenging problem currently facing the nuclear science community in this 21st century is design and development of novel structural materials, which will have an impact on the next-generation nuclear reactors. The materials available at present include reduced activation ferritic/martensitic steels, dispersion strengthened reduced activation ferritic steels, and vanadium- or tungsten-based alloys. These materials exhibit one or more specific problems, which are either intrinsic or caused by reactors. This work is focussed towards tungsten-yttrium (W-Y) based alloys and oxide ceramics, which can be utilized in nuclear applications. The goal is to derive a fundamental scientific understanding of W-Y-based materials. In collaboration with University of Califonia -- Davis, the project is designated to demonstrate the W-Y based alloys, ceramics and composites with enhanced physical, mechanical, thermo-chemical properties and higher radiation resistance. Efforts are focussed on understanding the microstructure, manipulating materials behavior under charged-particle and neutron irradiation, and create a knowledge database of defects, elemental diffusion/segregation, and defect trapping along grain boundaries and interfaces. Preliminary results will be discussed.

  16. Diagnosis and treatment of orofacial pain in a patient with unserviceable complete dentures: A clinical report.

    Science.gov (United States)

    Selecman, Audrey M; Ahuja, Swati A

    2018-02-08

    An ill-fitting complete denture has the potential to create pain and discomfort as well as conceal or confound the diagnosis of other primary sources of orofacial pain such as trigeminal neuralgia. Guidelines of the American Academy of Orofacial Pain offer an evidence-based approach for the assessment, diagnosis, and management of orofacial pain. A complete and accurate differential diagnosis is paramount to the success of treatment as well as to the circumvention of unnecessary therapy. The purpose of this clinical report was to emphasize an evidence-based approach to the diagnosis and treatment of orofacial pain in a patient with edentulism and a history of prolonged denture wear. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Sensor-based material tagging system

    International Nuclear Information System (INIS)

    Vercellotti, L.C.; Cox, R.W.; Ravas, R.J.; Schlotterer, J.C.

    1991-01-01

    Electronic identification tags are being developed for tracking material and personnel. In applying electronic identification tags to radioactive materials safeguards, it is important to measure attributes of the material to ensure that the tag remains with the material. The addition of a microcontroller with an on-board analog-to-digital converter to an electronic identification tag application-specific integrated-circuit has been demonstrated as means to provide the tag with sensor data. Each tag is assembled into a housing, which serves as a scale for measuring the weight of a paint-can-sized container and its contents. Temperature rise of the can above ambient is also measured, and a piezoelectric detector detects disturbances and immediately puts the tag into its alarm and beacon mode. Radiation measurement was also considered, but the background from nearby containers was found to be excessive. The sensor-based tagging system allows tracking of the material in cans as it is stored in vaults or is moved through the manufacturing process. The paper presents details of the sensor-based material tagging system and describes a demonstration system

  18. The adhesive strength and initial viscosity of denture adhesives.

    Science.gov (United States)

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  19. Light weight hollow maxillary complete denture: A case series

    Directory of Open Access Journals (Sweden)

    Laxman Singh Kaira

    2012-01-01

    Full Text Available Retention, stability and support are the basic principles on which the success of a complete denture relies on. The skill lies in applying these principles efficiently in critical situations. Residual ridge resorption occurs at a three times faster rate in mandibular arch than in the maxillary arch. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. The consequent weight of the processed complete denture only compromises them further. The severely resorbed jaw can have various treatment options. Extreme resorption of the maxillary denture-bearing area may lead to problems with prosthetic rehabilitation. The advantage of a hollow maxillary or mandibular denture is the reduction of excessive weight of acrylic resin, which normally replaces lost alveolar ridge in the interridge space of the denture wearer. This clinical report describes two case reports of edentulous patients with resorbed ridges where a simplified technique of fabricating a light weight hollow maxillary complete denture was used for the preservation of denture bearing areas.

  20. Quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures in general dental practice in England, Ireland and Wales in 2009.

    Science.gov (United States)

    Kilfeather, G P; Lynch, C D; Sloan, A J; Youngson, C C

    2010-04-01

    The aim of this study was to investigate the quality of communication and master impressions for the fabrication of cobalt chromium removable partial dentures (RPDs) in general dental practice in England, Ireland and Wales in 2009. Two hundred and ten questionnaires were distributed to 21 laboratories throughout England, Ireland and Wales. Information was collected regarding the quality of written communication and selection of master impression techniques for cobalt chromium partial dentures in general dental practice. One hundred and forty-four questionnaires were returned (response rate = 68%). Alginate was the most popular impression material being used in 58% of cases (n = 84), while plastic stock trays were the most popular impression tray, being used in 31% of cases (n = 44). Twenty-four per cent (n = 35) of impressions were not adequately disinfected. Opposing casts were provided in 81% of cases (n = 116). Written instructions were described as being 'clear' in 31% of cases (n = 44). In 54% of cases (n = 76), the technician was asked to design the RPD. Based on the findings of this study, written communication for cobalt chromium RPDs by general dental practitioners is inadequate. This finding is in breach of relevant contemporary legal and ethical guidance. There are also concerns in relation to the fabrication process for this form of prosthesis, particularly, in relation to consideration of occlusal schemes.

  1. Design and Manufacture of Customised Denture Frameworks Using Magics®/Autofab® and SLM

    OpenAIRE

    Kutiyal, S.; Moroz, Adam; Attenborough, E.; Alrbaey, K.

    2013-01-01

    Layer additive manufacturing technologies are progressing from rapid prototyping and rapid tooling. The development of finished parts made of metal powders without post processing is especially suitable for creation of precision part/object from small to mass customized fabrication; hence is the key application of these technologies. Laser based layer manufacturing techniques are mostly preferred in medical industry, particularly in the manufacture of denture frameworks; since these need to g...

  2. Evaluation of Oral Stereognostic Ability After Rehabilitating Patients with Complete Dentures: In Vivo Study

    OpenAIRE

    Meenakshi, S.; Gujjari, Anil Kumar; Thippeswamy, H. N.; Raghunath, N.

    2013-01-01

    Stereognosis has been defined as the appreciation of the form of objects by palpation. Whilst this definition holds good for the manual exploration of objects, it is possible for the shape of objects to be explored intra orally referred to as oral stereognosis. To better understand patients’ relative satisfaction with complete dentures, differences in oral stereognostic perception, based on the identification of 6 edible objects was analyzed in a group of 30 edentulous individuals at 3 stages...

  3. The effect of disinfectant solutions on the hardness of acrylic resin denture teeth.

    Science.gov (United States)

    Pavarina, A C; Vergani, C E; Machado, A L; Giampaolo, E T; Teraoka, M T

    2003-07-01

    This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degrees C for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degrees C for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.

  4. The Use of Implants to Improve Removable Partial Denture Function.

    Science.gov (United States)

    Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A

    2014-12-01

    The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.

  5. The role of friction in the mechanism of retaining the partial removable dentures with double crown system.

    Science.gov (United States)

    Dąbrowa, Tomasz; Dobrowolska, Anna; Wieleba, Wojciech

    2013-01-01

    Cylindrical telescopic crowns belong to bolt dentures, because their adhesion strength is based on the friction force. The magnitude of static and slide friction forces depends on the strain within the contact area and properties of materials employed. Friction force value between telescope elements declines in the first phase of wearing period and, subsequently, maintains particular constant value of 8 to 10 N. In the telescopic technique, homo and heterogenic joints are used. The following prosthodontic materials have been examined: goldbase alloys (Degudent Kiss, Degulor M), cobalt-base alloy (Brealloy 270), ceramics (Zircon Oxide, Zirconia) during tribological investigations on FGP composite resin. The cooperating surfaces were moistened with synthetic saliva. The research confirmed the dependence of the static friction coefficient on the contact pressure for the analyzed pairs of materials used in prosthodontics. The biggest effect of the contact pressure on the coefficient of friction value occurs when the ceramic rubs on FGP composite resin. The most stable friction coefficient in the context of contact pressure changes as well as life has been found in the case of the cobalt alloy Brealloy 270. An interesting material is a gold alloy Degulor M, for which the coefficient of friction varies only slightly with pressure in the range of 0.6 to 0.9 MPa.

  6. RPI and RPL clasp masticatory load distribution in lower free end denture case with photoelastic methods

    Directory of Open Access Journals (Sweden)

    Dahlia Sutanto

    2007-03-01

    Full Text Available The extent and direction of movement of removable partial dentures during function are influenced by the nature of supporting structures and the design of the prosthesis since forces are transmitted to abutment teeth by rest, guide planes, and direct retainers during functional movements. Because of the lack of tooth support distally, the denture base will have tissueward underfunction proportionate to the quality (displaceability of the supporting soft tissue, the accuracy of the denture base, and the total occlusal load applied. The movement of the base under function determines the occlusal efficiency of the partial denture and the degree to which the abutment teeth are subjected to torque and tipping stresses.The purpose of this study is to know the functional load exerts with RPI and RPL direct retainer in bilateral distal extension. This study is a laboratory experiment employing samples of 5 frames using RPI and 5 frames using RPL direct retainer design. Testing was conducted by Vishay Teaching Polariscope type 080. The result was noted and analyzed statistically using ANOVA.The result of this study indicates that F calculation value for frame with RPI and RPL direct retainer design is 5,35 and 6,11 Mpa; F calculation for the occlusal load distribution on first premolar and edentulous area is 276,90 Mpa and 171,53 Mpa; F calculation for occlusal load distribution on first premolar and edentulous area employing RPI and RPL direct retainer design is 9,17 and 11,96 Mpa. This statistical calculation shows that there is a significant difference between RPI and RPL direct retainer design, the occlusal load concentrated at edentulous area either RPI or RPL direct retainer, and the occlusal load distribution between the first premolar and edentulous area are more uniform on RPI direct retainer design.

  7. Reorientation simplified: A device for recording and reproducing the path of insertion for removable partial dentures

    Directory of Open Access Journals (Sweden)

    Vaibhav D Kamble

    2014-01-01

    Full Text Available Aim: The record of path of insertion on the dental cast is part of the dentist′s work authorization to the dental laboratory technician. The path of insertion record enables the dental technician to replace the cast on a surveyor in the same position that the dentist selected. Analysis of factors that influence the path of insertion should determine a path of insertion that will reduce the potential for dislodgement and promote stability of removable partial denture (RPD. Materials and Methods: The recording of the relation of a cast to a dental surveyor and the transfer of this relationship to the dental laboratory may be done by tripodization, by scoring the base of the cast, or by cementing a reference pin on the cast. Conclusion: Recording the established path of insertion can be difficult when the procedure uses a cemented pin and the casts are mounted in an articulator. This article describes a procedure for innovative dowel pin and sleeve device to record the path of insertion of RPDs, which serves the same purpose as the cemented pin but can be easily removed and replaced.

  8. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    Science.gov (United States)

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  9. Data base on structural materials aging properties

    International Nuclear Information System (INIS)

    Oland, C.B.

    1992-01-01

    The US Nuclear Regulatory Commission has initiated a Structural Aging Program at the Oak Ridge National Laboratory to identify potential structural safety issues related to continued service of nuclear power plants and to establish criteria for evaluating and resolving these issues. One of the tasks in this program focuses on the establishment of a Structural Materials Information Center where long-term and environment-dependent properties of concretes and other structural materials are being collected and assembled into a data base. These properties will be used to evaluate the current condition of critical structural components in nuclear power plants and to estimate the future performance of these materials during the continued service period

  10. Satellite Contamination and Materials Outgassing Knowledge base

    Science.gov (United States)

    Minor, Jody L.; Kauffman, William J. (Technical Monitor)

    2001-01-01

    Satellite contamination continues to be a design problem that engineers must take into account when developing new satellites. To help with this issue, NASA's Space Environments and Effects (SEE) Program funded the development of the Satellite Contamination and Materials Outgassing Knowledge base. This engineering tool brings together in one location information about the outgassing properties of aerospace materials based upon ground-testing data, the effects of outgassing that has been observed during flight and measurements of the contamination environment by on-orbit instruments. The knowledge base contains information using the ASTM Standard E- 1559 and also consolidates data from missions using quartz-crystal microbalances (QCM's). The data contained in the knowledge base was shared with NASA by government agencies and industry in the US and international space agencies as well. The term 'knowledgebase' was used because so much information and capability was brought together in one comprehensive engineering design tool. It is the SEE Program's intent to continually add additional material contamination data as it becomes available - creating a dynamic tool whose value to the user is ever increasing. The SEE Program firmly believes that NASA, and ultimately the entire contamination user community, will greatly benefit from this new engineering tool and highly encourages the community to not only use the tool but add data to it as well.

  11. Protein-Based Drug-Delivery Materials

    Directory of Open Access Journals (Sweden)

    Dave Jao

    2017-05-01

    Full Text Available There is a pressing need for long-term, controlled drug release for sustained treatment of chronic or persistent medical conditions and diseases. Guided drug delivery is difficult because therapeutic compounds need to survive numerous transport barriers and binding targets throughout the body. Nanoscale protein-based polymers are increasingly used for drug and vaccine delivery to cross these biological barriers and through blood circulation to their molecular site of action. Protein-based polymers compared to synthetic polymers have the advantages of good biocompatibility, biodegradability, environmental sustainability, cost effectiveness and availability. This review addresses the sources of protein-based polymers, compares the similarity and differences, and highlights characteristic properties and functionality of these protein materials for sustained and controlled drug release. Targeted drug delivery using highly functional multicomponent protein composites to guide active drugs to the site of interest will also be discussed. A systematical elucidation of drug-delivery efficiency in the case of molecular weight, particle size, shape, morphology, and porosity of materials will then be demonstrated to achieve increased drug absorption. Finally, several important biomedical applications of protein-based materials with drug-delivery function—including bone healing, antibiotic release, wound healing, and corneal regeneration, as well as diabetes, neuroinflammation and cancer treatments—are summarized at the end of this review.

  12. Pattern of Demand for Removable Acrylic Partial Denture (RPD) in ...

    African Journals Online (AJOL)

    Alasia Datonye

    prosthodontic need in the future. Furthermore, an overall ... As socio-economic depression continues to cut across the world particularly .... preserved. Data Management ... for lower partial denture in our study but Idowu and AI-. 12. Shamrani ...

  13. Molybdenum silicide based materials and their properties

    International Nuclear Information System (INIS)

    Yao, Z.; Stiglich, J.; Sudarshan, T.S.

    1999-01-01

    Molybdenum disilicide (MoSi 2 ) is a promising candidate material for high temperature structural applications. It is a high melting point (2030 C) material with excellent oxidation resistance and a moderate density (6.24 g/cm 3 ). However, low toughness at low temperatures and high creep rates at elevated temperatures have hindered its commercialization in structural applications. Much effort has been invested in MoSi 2 composites as alternatives to pure molybdenum disilicide for oxidizing and aggressive environments. Molybdenum disilicide-based heating elements have been used extensively in high-temperature furnaces. The low electrical resistance of silicides in combination with high thermal stability, electron-migration resistance, and excellent diffusion-barrier characteristics is important for microelectronic applications. Projected applications of MoSi 2 -based materials include turbine airfoils, combustion chamber components in oxidizing environments, missile nozzles, molten metal lances, industrial gas burners, diesel engine glow plugs, and materials for glass processing. On this paper, synthesis, fabrication, and properties of the monolithic and composite molybdenum silicides are reviewed

  14. Micromechanics Based Failure Analysis of Heterogeneous Materials

    Science.gov (United States)

    Sertse, Hamsasew M.

    In recent decades, heterogeneous materials are extensively used in various industries such as aerospace, defense, automotive and others due to their desirable specific properties and excellent capability of accumulating damage. Despite their wide use, there are numerous challenges associated with the application of these materials. One of the main challenges is lack of accurate tools to predict the initiation, progression and final failure of these materials under various thermomechanical loading conditions. Although failure is usually treated at the macro and meso-scale level, the initiation and growth of failure is a complex phenomena across multiple scales. The objective of this work is to enable the mechanics of structure genome (MSG) and its companion code SwiftComp to analyze the initial failure (also called static failure), progressive failure, and fatigue failure of heterogeneous materials using micromechanics approach. The initial failure is evaluated at each numerical integration point using pointwise and nonlocal approach for each constituent of the heterogeneous materials. The effects of imperfect interfaces among constituents of heterogeneous materials are also investigated using a linear traction-displacement model. Moreover, the progressive and fatigue damage analyses are conducted using continuum damage mechanics (CDM) approach. The various failure criteria are also applied at a material point to analyze progressive damage in each constituent. The constitutive equation of a damaged material is formulated based on a consistent irreversible thermodynamics approach. The overall tangent modulus of uncoupled elastoplastic damage for negligible back stress effect is derived. The initiation of plasticity and damage in each constituent is evaluated at each numerical integration point using a nonlocal approach. The accumulated plastic strain and anisotropic damage evolution variables are iteratively solved using an incremental algorithm. The damage analyses

  15. Transportation of ions through cement based materials

    International Nuclear Information System (INIS)

    Chatterji, S.

    1994-01-01

    Transportation of ions, both anions and cations, through cement based materials is one of the important processes in their durability and as such has been studied very extensively. It has been studied from the point of view of the reinforcement corrosion, alkali-silica reaction, sulfate attack on cement and concrete, as well as in the context of the use of the cement based materials in the disposal of nuclear waste. In this paper the fundamental equations of diffusion, i.e. Fick's two equations, Nernst and Nernst-Planck equations have been collected. Attention has been drawn to the fact that Fick's two equations are valid for non-ionic diffusants and that for ions the relevant equations are those of Nernst and Nernst-Planck. The basic measurement techniques have also been commented upon

  16. Denture identification using unique identification authority of India barcode

    OpenAIRE

    Sudhindra Mahoorkar; Anoop Jain

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  17. Denture identification using unique identification authority of India barcode.

    Science.gov (United States)

    Mahoorkar, Sudhindra; Jain, Anoop

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  18. Radiation hardened equipment and material data base

    International Nuclear Information System (INIS)

    Sumita, Kenji; Yamaoka, Hitoshi; Kakuta, Tsunemi; Shono, Yoshihiko; Nakamura, Tetsuo; Nakase, Yoshiaki; Furuta, Junichiro.

    1988-01-01

    In order to collect and put in order the results regarding radiation-withstanding equipment and materials, the Osaka Nuclear Science Association organized the committee composed of the experts in various fields in fiscal year 1986 for the purpose of building up the data base, and began the activity. From the trend of the research and development and the usefulness for the future, the fields of collecting data were decided as organic materials, optical fibers, semiconductor elements and compound semiconductors. By fiscal year 1987, the building-up of the prototype data base was aimed at, and system configuration, the making of the formats on the items and attributes of collected data, the action test of the system and so on were carried out. Under the background of the upgrading of LWRs, the development of FBRs and nuclear fusion reactors, the construction of a reprocessing plant and a low level waste storage facility, and the progress of various advanced technologies, the research on the equipment and materials having excellent radiation resistance and the development for heightening the performance have been carried out in many places separately, accordingly the activity for building up the prototype data base was begun, and about 600 cases were collected. (Kako, I.)

  19. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface.

    Science.gov (United States)

    Vieira, Ana Paula Coelho; Senna, Plínio Mendes; Silva, Wander José da; Del Bel Cury, Altair Antoninha

    2010-01-01

    This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate)-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min), 0.5% sodium hypochlorite (10 min) or distilled water (control; 15 min). After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL). Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05). Results of cell count estimation showed significant differences in cleanliness among the treatments (p 0.05) was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p recolonization.

  20. Complex coacervate-based materials for biomedicine.

    Science.gov (United States)

    Blocher, Whitney C; Perry, Sarah L

    2017-07-01

    There has been increasing interest in complex coacervates for deriving and transporting biomaterials. Complex coacervates are a dense, polyelectrolyte-rich liquid that results from the electrostatic complexation of oppositely charged macroions. Coacervates have long been used as a strategy for encapsulation, particularly in food and personal care products. More recent efforts have focused on the utility of this class of materials for the encapsulation of small molecules, proteins, RNA, DNA, and other biomaterials for applications ranging from sensing to biomedicine. Furthermore, coacervate-related materials have found utility in other areas of biomedicine, including cartilage mimics, tissue culture scaffolds, and adhesives for wet, biological environments. Here, we discuss the self-assembly of complex coacervate-based materials, current challenges in the intelligent design of these materials, and their utility applications in the broad field of biomedicine. WIREs Nanomed Nanobiotechnol 2017, 9:e1442. doi: 10.1002/wnan.1442 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.

  1. Fracture behavior of W based materials

    International Nuclear Information System (INIS)

    Hack, J.E.

    1991-01-01

    This report describes the results of a program to investigate the fracture properties of tungsten based materials. In particular, the role of crack velocity on crack instability was determined in a W-Fe-Ni-Co ''heavy alloy'' and pure polycrystalline tungsten. A considerable effort was expended on the development of an appropriate crack velocity gage for use on these materials. Having succeeded in that, the gage technology was employed to determine the crack velocity response to the applied level of stress intensity factor at the onset of crack instability in pre-cracked specimens. The results were also correlated to the failure mode observed in two material systems of interest. Major results include: (1) unstable crack velocity measurements on metallic specimens which require high spatial resolution require the use of brittle, insulating substrates, as opposed to the ductile, polymer based substrates employed in low spatial resolution measurements; and (2) brittle failure modes, such as cleavage, are characterized by relatively slow unstable crack velocities while evidence of high degrees of deformation are associated with failures which proceed at high unstable crack velocities. This latter behavior is consistent with the predictions of the modeling of Hack et al and may have a significant impact on the interpretation of fractographs in general

  2. Quantitative Estimation of Yeast on Maxillary Denture in Patients with Denture Stomatitis and the Effect of Chlorhexidine Gluconate in Reduction of Yeast

    Directory of Open Access Journals (Sweden)

    Jaykumar R Gade

    2011-01-01

    Full Text Available Denture stomatitis is a condition associated with wearing of a denture. The predisposing factor leading to denture stomatitis could be poor oral hygiene, ill-fitting denture and relief areas. Around 30 patients with denture stomatitis were advised to rinse with chlorhexidine gluconate mouthwash for 14 days and were directed to immerse the upper denture in the chlorhexidine solution for 8 hours. The samples were collected by scraping maxillary denture in saline at three intervals, prior to, at the end of 24 hours and after 14 days of treatment, then were inoculated and quantitative estimation of the yeast growth on Sabouraud′s dextrose agar plate was done. It was observed that after a period of 14 days, there was a reduction in the growth of yeast and also improvement in the clinical picture of the oral mucosa

  3. Resilient Modulus Characterization of Alaskan Granular Base Materials

    Science.gov (United States)

    2010-08-01

    Resilient modulus (MR) of base course material is an important material input for : pavement design. In Alaska, due to distinctiveness of local climate, material source, : fines content and groundwater level, resilient properties of D-1 granular base...

  4. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method

    Directory of Open Access Journals (Sweden)

    Radović Katarina

    2010-01-01

    Full Text Available Introduction. Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral freeend saddle denture without major connector was taken into consideration. Objective. The aim was to analyze and compare a unilateral RPD (removable partial denture and a classical RPD by calculating and analyzing stresses under different loads. Methods. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made. The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. Results. The Fault Model Extractor (FME analysis and calculation showed the complete behavior of unilateral removable partial denture and abutments (canine and first premolar, as well as the behavior of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Conclusion. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values.

  5. Developing the procedure of modifying the denture soft liner by silver nanoparticles.

    Science.gov (United States)

    Chladek, Grzegorz; Barszczewska-Rybarek, Izabela; Lukaszczyk, Jan

    2012-01-01

    Colonization of denture soft lining materials by fungi and denture plaque leads to infections of mucosa. Microorganisms such as Candida albicans colonize not only the surface of the soft liners, but they also penetrate inside those materials. Therefore the use of common disinfectants, e.g., surface active cleaners, is not a perfect solution for keeping a proper hygiene of soft linings. Modifying soft lining by silver nanoparticles (AgNP) seems to be a right way to overcome those problems. The procedure of modifying two-component silicone material by silver nanoparticles (AgNP) is presented in the article. The solubility tests for both material components have been carried out in the first stage of examinations. On the basis of test results, a solvent has been selected, being a dispersion medium for AgNPs and both soft liner components. The effective method for evaporating a solvent from the composition has been developed. Material components with various AgNP concentrations (10, 20, 40, 80, 120 and 200 ppm) have been obtained. Cured samples of the composites have been examined by SEM to confirm the effectiveness of the procedure.

  6. Bibliographic data base for low activation materials

    International Nuclear Information System (INIS)

    Alenina, M.V.; Kolotov, V.P.; Ivanov, L.I.

    2007-01-01

    Full text of publication follows: The analysis of the publications dealing with development of low-activation materials for fusion technology demonstrates that the period of information doubling is about 5-6 years. Such high rate usually is characteristic of the actively developing field of science. To develop an useful instrument for analysis and systematization of the available data a computer based bibliographic system has been developed some time ago. Recently the engine of the system has been significantly modernized. The bibliographic system is based on using of MS SQL server data base which includes main bibliographic information including abstracts. The most important feature of the system is that full-text abstracts searching capabilities are appended with indexing of information by experts to increase its definition. The experts indexes cover the following topics: - Main problems; - Software and methods for calculation; - Libraries of nuclear data; - Spectrum of neutrons for different construction parts of fusion reactor; - Low activation materials; - Technology of production; - Radiation effects; - Utilization of radiation waste; - Estimation of risks; - Designs of fusion reactor; - Nuclear transmutations; - Equipment used for investigations. The primary data base is filling/appending by periodical queries to different bibliographic data bases (INIS, COMPEMDEX and others) via suitable Internet providers including strict analysis of the income information to remove a possible 'information noise' and following data indexing by experts. The data base contains references since 1976 year (when first works in this area have been fulfilled) and until now. The bibliographic system is accessible by means of Internet using different forms developed for queries (http://www.geokhi.ru/~lam_db). (authors)

  7. Bibliographic data base for low activation materials

    Energy Technology Data Exchange (ETDEWEB)

    Alenina, M.V.; Kolotov, V.P. [Vernadsky Institute of Geochemistry and Analytical Chemistry, Moscow (Russian Federation); Ivanov, L.I. [A.A. Baikov Institute of Metallurgy and Science of Materials, Russian Academy of Sciences, Moscow (Russian Federation)

    2007-07-01

    Full text of publication follows: The analysis of the publications dealing with development of low-activation materials for fusion technology demonstrates that the period of information doubling is about 5-6 years. Such high rate usually is characteristic of the actively developing field of science. To develop an useful instrument for analysis and systematization of the available data a computer based bibliographic system has been developed some time ago. Recently the engine of the system has been significantly modernized. The bibliographic system is based on using of MS SQL server data base which includes main bibliographic information including abstracts. The most important feature of the system is that full-text abstracts searching capabilities are appended with indexing of information by experts to increase its definition. The experts indexes cover the following topics: - Main problems; - Software and methods for calculation; - Libraries of nuclear data; - Spectrum of neutrons for different construction parts of fusion reactor; - Low activation materials; - Technology of production; - Radiation effects; - Utilization of radiation waste; - Estimation of risks; - Designs of fusion reactor; - Nuclear transmutations; - Equipment used for investigations. The primary data base is filling/appending by periodical queries to different bibliographic data bases (INIS, COMPEMDEX and others) via suitable Internet providers including strict analysis of the income information to remove a possible 'information noise' and following data indexing by experts. The data base contains references since 1976 year (when first works in this area have been fulfilled) and until now. The bibliographic system is accessible by means of Internet using different forms developed for queries (http://www.geokhi.ru/{approx}lam{sub d}b). (authors)

  8. Properties of materials based on polybenzimidazopyrrolone

    Energy Technology Data Exchange (ETDEWEB)

    Korshak, L L; Lekaye, I A; Vinogradova, O V; Chatova, L L; Lekaye, T V; Rusanov, A L

    1980-01-01

    Polymers based on polyheteroarylene compounds are characterized by high radiation and ablation resistance and are prepared by a two-stage synthesis:preparation of the soluble polyamidoamino acids (PAAA's), and polycondensation by thermal intramolecular polycyclodehydration of the PAAA's. Three types of polymers were prepared by the reaction in dimethylformamide of 3,3',4,4'-tetraminodiphenyl-oxide with the dianhydrides of diphenyloxide-, benzophenone-, and diphenylsulfon-tetracarbonic acids and pyromellitic acid. An evaluation was made of the optimum regimes for extruding these polymers and of the properties of the extruded material. (JMT)

  9. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures.

    NARCIS (Netherlands)

    Creugers, N.H.J.; Witter, D.J.; Spijker, A. van 't; Gerritsen, A.E.; Kreulen, C.M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches

  10. Removable partial or complete dentures exposed to beverages and mouthwashes: evaluation of microhardness and roughness

    Directory of Open Access Journals (Sweden)

    Fernanda Alves Feitosa

    Full Text Available AbstractPurposeTo evaluate microhardness and roughness of denture base polymethylmethacrylate resinn exposed to acid beverages and mouthwashes.Material and methodRectangular samples (n=80 were prepared from poly (methyl methacrylate (PMMA. They were divided into 8 groups and had the initial microhardness and Knoop roughness measured. Samples of each group were immersed for 10 min into a test solution (coffee, lemon juice, chlorhexidine gluconate, red wine, cola-based soft drink, vinegar or antiseptic with and without alcohol and after stored in artificial saliva for 23 h and 50 min, completing a period of 24 h. This procedure was performed for 14 consecutive days and after this period the microhardness and surface roughness measurements were made again. Data were statistically analyzed using ANOVA non parametric, Kruskal-Walis and the Dunn´s test for microhardness and the t-Student and ANOVA for roughness.ResultFor microhardness there were found statistically significant differences among the chlorhexidine gluconate solution, antiseptic without alcohol and cola-based soft drink. For roughness was observed that the mean values between the initial period and after immersion in the test products differed statistically in all groups, without difference among groups.ConclusionThe microhardness of poly(methyl methacrylate was affected by continue exposition to chlorhexidine gluconate, antiseptic without alcohol and cola-based soft drink. The roughness of poly(methyl methacrylate is negatively influenced by the exposure to all tested products. It may be concluded that both, microhardness and roughness, were affected by the treatments.

  11. Influence of denture adhesives on occlusion and disocclusion times.

    Science.gov (United States)

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (PAdhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Radiation detectors based by polymer materials

    International Nuclear Information System (INIS)

    Cherestes, Margareta; Cherestes, Codrut; Constantinescu, Livia

    2004-01-01

    Scintillation counters make use of the property of certain chemical compounds to emit short light pulses after excitation produced by the passage of charged particles or photons of high energy. These flashes of light are detected by a photomultiplier tube that converts the photons into a voltage pulse. The light emitted from the detector also can be collected, focussed and dispersed by a CCD detector. The study of the evolution of the light emission and of the radiation damage under irradiation is a primary topic in the development of radiation hard polymer based scintillator. Polymer scintillator thin films are used in monitoring radiation beam intensities and simultaneous counting of different radiations. Radiation detectors have characteristics which depend on: the type of radiation, the energy of radiation, and the material of the detector. Three types of polymer thin films were studied: a polyvinyltoluene based scintillator, fluorinated polyimide and PMMA. (authors)

  13. Nanocellulose-Based Materials for Water Purification.

    Science.gov (United States)

    Voisin, Hugo; Bergström, Lennart; Liu, Peng; Mathew, Aji P

    2017-03-05

    Nanocellulose is a renewable material that combines a high surface area with high strength, chemical inertness, and versatile surface chemistry. In this review, we will briefly describe how nanocellulose is produced, and present-in particular, how nanocellulose and its surface modified versions affects the adsorption behavior of important water pollutants, e.g., heavy metal species, dyes, microbes, and organic molecules. The processing of nanocellulose-based membranes and filters for water purification will be described in detail, and the uptake capacity, selectivity, and removal efficiency will also be discussed. The processing and performance of nanocellulose-based membranes, which combine a high removal efficiency with anti-fouling properties, will be highlighted.

  14. Nanocellulose-Based Materials for Water Purification

    Directory of Open Access Journals (Sweden)

    Hugo Voisin

    2017-03-01

    Full Text Available Nanocellulose is a renewable material that combines a high surface area with high strength, chemical inertness, and versatile surface chemistry. In this review, we will briefly describe how nanocellulose is produced, and present—in particular, how nanocellulose and its surface modified versions affects the adsorption behavior of important water pollutants, e.g., heavy metal species, dyes, microbes, and organic molecules. The processing of nanocellulose-based membranes and filters for water purification will be described in detail, and the uptake capacity, selectivity, and removal efficiency will also be discussed. The processing and performance of nanocellulose-based membranes, which combine a high removal efficiency with anti-fouling properties, will be highlighted.

  15. The influence of removable partial dentures on the periodontal health of abutment and non-abutment teeth

    OpenAIRE

    Dula, Linda J.; Shala, Kujtim Sh.; Pustina–Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.

    2015-01-01

    Objective: The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. Materials and Methods: A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probin...

  16. The analysis of the mechanical properties of F75 Co-Cr alloy for use in selective laser melting (SLM manufacturing of removable partial dentures (RPD

    Directory of Open Access Journals (Sweden)

    D. Jevremovic

    2012-04-01

    Full Text Available The presented work discusses the applicability of the selective laser melting technique (SLM in manufacture of removable partial denture (RPD frameworks with the emphasis on material properties. The paper presents initial results of a conducted test of the mechanical properties of the F75 Co-Cr dental alloy used with selective laser melting.

  17. Photodynamic antimicrobial therapy in the treatment of denture stomatitis; Terapia fotodinamica antimicrobiana no tratamento da estomatite protetica

    Energy Technology Data Exchange (ETDEWEB)

    Senna, Andre Machado de

    2012-07-01

    Denture stomatitis (DS), also called chronic atrophic candidiasis, is the most common oral fungal infection in denture wearers. It has a multifactorial etiology, but the presence of Candida spp. biofilm on the denture is considered the most important factor for the establishment of the DS. This study aimed to evaluate the treatment of DS through the use of photodynamic antimicrobial therapy (PAT), mediated by methylene blue. For this purpose, preclinical studies and clinical trials were performed. Simulators prototypes dentures were made of methyl methacrylate polymer to serve as a basis for biofilm growth of the following species of Candida: C. albicans, C. glabrata, C. dubliniensis, C. krusei, C. tropicalis, C. parapsilosis and C. guilliermondii. Methylene blue solution at a concentration of 450 {mu}g/mL was used as a photosensitizer. The prototypes and biofilms were irradiated with a laser of wavelength of 660 nm, potency of 100 mW, for 80 seconds. For the clinical study, subjects were divided into two groups. The first group received conventional treatment based on the use of antifungal Miconazole. The second group received the treatment by PAT. The preclinical results showed that all species of the genus Candida were susceptible to PAT, with a reduction in colonies that ranged from 2.48 to 3.93 log{sub 10}. Clinical outcomes were evaluated for the reduction of colonies of Candida spp. located in the mucosa and in the prosthesis and relative to the improvement of the clinical aspect of the affected mucosa. Both the conventional therapy and PAT were effective in treating DS. There was no significant statistical difference between PAT and conventional treatment for any of the factors evaluated. Thus, it was concluded that PAT is effective in the treatment of denture stomatitis. (author)

  18. Effects of Impression Material, Impression Tray Type, and Type of Partial Edentulism on the Fit of Cobalt-Chromium Partial Denture Frameworks on Initial Clinical Insertion: A Retrospective Clinical Evaluation.

    Science.gov (United States)

    Baig, Mirza Rustum; Akbar, Jaber Hussain; Qudeimat, Muawia; Omar, Ridwaan

    2018-02-15

    To evaluate the effects of impression material, impression tray type, and type of partial edentulism (ie, Kennedy class) on the accuracy of fit of cobalt-chromium (Co-Cr) partial removable dental prostheses (PRDP) in terms of the number of fabricated frameworks required until the attainment of adequate fit. Electronic case documentations of 120 partially edentulous patients provided with Co-Cr PRDP treatment for one or both arches were examined. Statistical analyses of data were performed using analysis of variance and Tukey honest significant difference test to compare the relationships between the different factors and the number of frameworks that needed to be fabricated for each patient (α = .05). Statistical analysis of data derived from 143 records (69 maxillary and 74 mandibular) revealed no significant correlation between impression material, tray type, or Kennedy class and the number of construction attempts for the pooled or individual arch data (P ≥ .05). In PRDP treatment, alginate can be chosen as a first-choice material, and metal stock trays can be a preferred option for making final impressions to fabricate Co-Cr frameworks.

  19. Provision of a swing lock denture for a patient with Gorlin Goltz syndrome.

    Science.gov (United States)

    Razaq, I; Durey, K; Nattress, B

    2012-09-01

    Swinglock dentures are used relatively infrequently but in cases of compromised anatomy or where the pattern of tooth loss is unfavourable, they provide a useful removable partial denture design option. The aim of this article is to provide a clear summary of the clinical and technical considerations necessary when providing a Swinglock denture.

  20. Evaluation of Prevalence of Oral Candidiasis in Patients Using Complete Denture Wears

    Directory of Open Access Journals (Sweden)

    P Tavakkol

    2001-06-01

    Full Text Available Denture stomatotos os a common problem of the denture wears, and its etiology is not clear from the literatures. Some studies show that the aetiology is candida albicans, while other reports point out the other agents including candida albicans. The present study was designed to evaluate the prevalence of oral candidiasis in patients using complete denture with different datas. 50 subjects all wearing complete denture participated in this study. The palatal mucosa was swabbed and swabs were cultured in Sabourauds medium containing 0.005% chloramphenicol then cultures were tested with common mycological lab tests. In 80% of patients oral candidiasis have been diagnosed. In the investigation a direct relation between the oral candidiasis and removal of denture at night, denture cleanliness, presence of any suction and symptoms of denture stomatitis was shown. No relation between the oral candidiasis and sex, smoking habit, succeptible disease, angular cheilitis; the recent condition of denture and the retention of denture were found. The findings of our investigation indicates that candida albicans is the causative agent of denture stomatitis while other factors such as denture cleanliness, removal of denture at night and presence of any suction may be considered as well.

  1. The oral microbiome of denture wearers is influenced by levels of natural dentition

    NARCIS (Netherlands)

    O'Donnell, L.E.; Robertson, D.; Nile, C.J.; Cross, L.J.; Riggio, M.; Sherriff, A.; Bradshaw, D.; Lambert, M.; Malcolm, J.; Buijs, M.J.; Zaura, E.; Crielaard, W.; Brandt, B.W.; Ramage, G.

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to

  2. Sulfur based electrode materials for secondary batteries

    Science.gov (United States)

    Hao, Yong

    Developing next generation secondary batteries has attracted much attention in recent years due to the increasing demand of high energy and high power density energy storage for portable electronics, electric vehicles and renewable sources of energy. This dissertation investigates sulfur based advanced electrode materials in Lithium/Sodium batteries. The electrochemical performances of the electrode materials have been enhanced due to their unique nano structures as well as the formation of novel composites. First, a nitrogen-doped graphene nanosheets/sulfur (NGNSs/S) composite was synthesized via a facile chemical reaction deposition. In this composite, NGNSs were employed as a conductive host to entrap S/polysulfides in the cathode part. The NGNSs/S composite delivered an initial discharge capacity of 856.7 mAh g-1 and a reversible capacity of 319.3 mAh g-1 at 0.1C with good recoverable rate capability. Second, NGNS/S nanocomposites, synthesized using chemical reaction-deposition method and low temperature heat treatment, were further studied as active cathode materials for room temperature Na-S batteries. Both high loading composite with 86% gamma-S8 and low loading composite with 25% gamma-S8 have been electrochemically evaluated and compared with both NGNS and S control electrodes. It was found that low loading NGNS/S composite exhibited better electrochemical performance with specific capacity of 110 and 48 mAh g-1 at 0.1C at the 1st and 300th cycle, respectively. The Coulombic efficiency of 100% was obtained at the 300th cycle. Third, high purity rock-salt (RS), zinc-blende (ZB) and wurtzite (WZ) MnS nanocrystals with different morphologies were successfully synthesized via a facile solvothermal method. RS-, ZB- and WZ-MnS electrodes showed the capacities of 232.5 mAh g-1, 287.9 mAh g-1 and 79.8 mAh g-1 at the 600th cycle, respectively. ZB-MnS displayed the best performance in terms of specific capacity and cyclability. Interestingly, MnS electrodes

  3. The materials processing research base of the Materials Processing Center

    Science.gov (United States)

    Latanision, R. M.

    1986-01-01

    An annual report of the research activities of the Materials Processing Center of the Massachusetts Institute of Technology is given. Research on dielectrophoresis in the microgravity environment, phase separation kinetics in immiscible liquids, transport properties of droplet clusters in gravity-free fields, probes and monitors for the study of solidification of molten semiconductors, fluid mechanics and mass transfer in melt crystal growth, and heat flow control and segregation in directional solidification are discussed.

  4. Alveolar ridge rehabilitation to increase full denture retention and stability

    Directory of Open Access Journals (Sweden)

    Mefina Kuntjoro

    2010-12-01

    Full Text Available Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augmentation and vestibuloplasty was aimed to provide stability and retentive denture atrophic mandibular alveolar ridge. Case: A 65 years old woman patient complained about uncomfortable denture. Clinical evaluate showed flat ridge in the anterior mandible, flabby tissue and candidiasis, while residual ridge height was classified into class IV. Case management: Augmentation using autograph was conducted as the mandible vertical height is less than 15 mm. Autograph was used to achieve better bone quantity and quality. Separated alveolar ridge was conducted from left to right canine region and was elevated 0.5 mm from the previous position to get new ridge in the anterior region. The separated alveolar ridge was fixated by using T-plate and ligature wire. Three months after augmentation fixation appliances was removed vestibuloplasty was performed to increase denture bearing area that can make a stable and retentive denture. Conclusion: Augmentation and vestibuloplasty can improve flat ridge to become prominent.Latar belakang: Ridge mandibula yang atrofi pada umumnya mempersulit pembuatan restorasi prostetik terutama gigi tiruan lengkap (GTL. Residual alveolar ridge dan basal seat yang rendah menyebabkan gigi tiruan menjadi tidak stabil, menimbulkan ulser permanen, nyeri, neuralgia, dan kesulitan mengunyah. Tujuan: Augmentasi dan vestibuloplasti pada ridge mandibula yang atrofi dilakukan untuk menciptakan gigi tiruan yang stabil dan retentive. Kasus: Pasien wanita

  5. A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Namrata Agrawal

    2018-01-01

    Conclusion: Two implant-supported mandibular overdenture with ball and socket attachments incorporated by indirect technique showed higher values in terms of retention and absence of disengagement/fracture of components.

  6. Removable partial denture alloys processed by laser-sintering technique.

    Science.gov (United States)

    Alageel, Omar; Abdallah, Mohamed-Nur; Alsheghri, Ammar; Song, Jun; Caron, Eric; Tamimi, Faleh

    2018-04-01

    Removable partial dentures (RPDs) are traditionally made using a casting technique. New additive manufacturing processes based on laser sintering has been developed for quick fabrication of RPDs metal frameworks at low cost. The objective of this study was to characterize the mechanical, physical, and biocompatibility properties of RPD cobalt-chromium (Co-Cr) alloys produced by two laser-sintering systems and compare them to those prepared using traditional casting methods. The laser-sintered Co-Cr alloys were processed by the selective laser-sintering method (SLS) and the direct metal laser-sintering (DMLS) method using the Phenix system (L-1) and EOS system (L-2), respectively. L-1 and L-2 techniques were 8 and 3.5 times more precise than the casting (CC) technique (p laser-sintered and cast alloys were biocompatible. In conclusion, laser-sintered alloys are more precise and present better mechanical and fatigue properties than cast alloys for RPDs. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1174-1185, 2018. © 2017 Wiley Periodicals, Inc.

  7. Base technology development of new materials for FBR performance innovations

    International Nuclear Information System (INIS)

    Kano, Shigeki; Koyama, Masahiro; Nomura, Shigeo; Morikawa, Satoru; Ueno, Fumiyoshi

    1989-01-01

    This paper describes the base technology development of new materials for FBR performance innovations at the Power Reactor and Nuclear Fuel Development Corporation. The contents are as follows: (1) development of sodium and radiation resistant new materials, (2) development of high performance shielding material, (3) development of high performance control material, (4) development of new functional materials for reactor instrumentation. (author)

  8. Prefabricated light-polymerizing plastic pattern for partial denture framework

    Directory of Open Access Journals (Sweden)

    Atsushi Takaichi

    2011-01-01

    Full Text Available Our aim is to report an application of a prefabricated light-polymerizing plastic pattern to construction of removable partial denture framework without the use of a refractory cast. A plastic pattern for the lingual bar was adapted on the master cast of a mandibular Kennedy class I partially edentulous patient. The pattern was polymerized in a light chamber. Cobalt-chromium wires were employed to minimize the potential distortion of the plastic framework. The framework was carefully removed from the master cast and invested with phosphate-bonded investment for the subsequent casting procedures. A retentive clasp was constructed using 19-gauge wrought wire and was welded to the framework by means of laser welding machine. An excellent fit of the framework in the patient′s mouth was observed in the try-in and the insertion of the denture. The result suggests that this method minimizes laboratory cost and time for partial denture construction.

  9. [Correlation of psychoemotional status and adaptation to complete dentures].

    Science.gov (United States)

    Barkan, I Yu; Stafeev, A A; Repin, V S

    2015-01-01

    Patients with full adentia are characterized by the formation of specific psycho-emotional status. Rational psychotherapeutic support of these patients largely determines the efficiency of dental prosthetic treatment. At the same time, the definition of mental and emotional status is not included in the diagnostic examination protocol. Considering the above the purpose of the study was to evaluate mental and emotional status of patients receiving complete dentures. Prosthetic rehabilitation of 30 patients with complete teeth loss was performed and clinical evaluation and evaluation of mental and emotional status were carried out before and after treatment. Patients with negative experiences of prosthetics showed a higher level of personal and situational anxiety. There was correlation of adaptation to removable dentures and the patient's personality traits. It is determined that emotional instability during treatment tends to decrease affecting the timing of adaptation to complete dentures. It is noted that patients with repeated prosthetics have earlier recovery of coordination ability of the masticatory muscles.

  10. Bond strength of hard chairside reline resins to a rapid polymerizing denture base resin before and after thermal cycling Resistência de união de resinas rígidas para reembasamento imediato a resina para base de prótese de rápida polimerização antes e após termociclagem

    Directory of Open Access Journals (Sweden)

    Karin Hermana Neppelenbroek

    2006-12-01

    Full Text Available PURPOSE: This study assessed the shear bond strength of 4 hard chairside reline resins (Kooliner, Tokuso Rebase Fast, Duraliner II, Ufi Gel Hard to a rapid polymerizing denture base resin (QC-20 processed using 2 polymerization cycles (A or B, before and after thermal cycling. MATERIALS AND METHODS: Cylinders (3.5 mm x 5.0 mm of the reline resins were bonded to cylinders of QC-20 polymerized using cycle A (boiling water-20 minutes or B (boiling water; remove heat-20 minutes; boiling water-20 minutes. For each reline resin/polymerization cycle combination, 10 specimens (groups CAt e CBt were thermally cycled (5 and 55 ºC; dwell time 30 seconds; 2,000 cycles; the other 10 were tested without thermal cycling (groups CAwt ad CBwt. Shear bond tests (0.5 mm/min were performed on the specimens and the failure mode was assessed. Data were analyzed by 3-way ANOVA and Newman-Keuls post-hoc test (alpha=.05. RESULTS: QC-20 resin demonstrated the lowest bond strengths among the reline materials (POBJETIVO: Esse estudo avaliou a resistência de união ao cisalhamento de 4 resinas rígidas para reembasamento imediato (Kooliner, Tokuso Rebase Fast, Duraliner II, Ufi Gel Hard a uma resina para base de prótese de rápida polimerização (QC-20 submetida a 2 ciclos de polimerização (A e B, antes e após termociclagem. MATERIAIS E MÉTODOS: Cilindros (3,5 mm x 5,0 mm das resinas reembasadoras foram unidas aos cilindros de resina QC-20 polimerizados pelo ciclo A (água fervente - 20 minutos ou B (água fervente; remoção do calor-20 minutos; água fervente-20 minutos. Para cada combinação resina reembasadora/ciclo de polimerização, 10 corpos-de-prova (grupos CAt e CBt foram termociclados (5 e 55 ºC; intervalo de tempo 30 segundos; 2.000 ciclos; os outros 10 foram testados sem termociclagem (grupos CAwt e CBwt. Os testes de resistência de união ao cisalhamento (0,5 mm/min foram realizados sobre os corpos-de-prova e o tipo de falha avaliado. Os dados foram

  11. [Routine oral examinations and specific after-care for removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    Following treatment with a removable partial denture, routine oral examinations are required to stabilize the existing condition in a sustainable way and to make possible the timely treatment of anomalies which have appeared. In cases of problems assessed during a routine oral examination in relation to the removable partial dentures, maintenance, restorative and prosthetic treatment may be indicated. Maintenance treatments are indicated for small and easily retrievable alterations. In removable partial denture treatment, adequate space between prepared tooth and denture is essential. Possible prosthetic treatments of a removable partial denture are relining, rebasing, improving or renewing the maxillomandibular relation, repairment, and extension.

  12. Rare earth oxyhalogenide base thermoluminescent material

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1976-01-01

    A process is described that consists to expose a thermoluminescent material to ionizing radiations, the material being a rare earth oxyhalogenide with terbium additions, to heat this material up to the emission of visible radiations and to measure the emitted radiations which are proportional to the ionizing radiation dose [fr

  13. Characteristics of secondary radiation from fixed dentures under γ-therapy of cancerous new growth of maxillofacial region

    International Nuclear Information System (INIS)

    Gadjiyev, D.K.

    2002-01-01

    Literary data and own clinical investigations evidence that during carrying out of remote γ-therapy of cancerous new growth in head and neck regions it is possible secondary influence of rays on oral cavity tissues: parodont, mucous membrane of oral cavity, lachrymal glands, receptor mechanism. It is connected with high irradiation dose of these tissues as a result of secondary radiation from natural teeth and fixed metal dentures. Taking into consideration the secondary irradiation factor from metal dentures, we carried out experimental investigations at the Department of Radiation Researches of Azerbaijan National Academy of Sciences with the purpose of dose detection are produced by inverse scattering and secondary electron irradiation from modern dental metal materials: gold-alloy, cobalt- chromium alloy, silver-palladium alloy, titanium nitride alloy, metallic-ore ceramics, stainless steel. Standard metallic samples of these materials by area 100 mm 2 and thickness 25 mm have been irradiated by GUT-Co-400 device with I Gy dose at F=60 cm. Secondary irradiation intensity has been determined by photometry. Plate from stainless steel is as an standard. The results of carried out investigation shown the strengthening of scattering irradiation from 12 to 38 % with electrons track length from 0.8 to 1.9 mm are dependence from metal atomic weight. Tooth plastic protective kappa with thickness 3 mm for teeth of upper and lower jaws has been proposed with the purpose of prophylaxis of negative secondary irradiation influence to the tissue of oral cavity from metal dentures

  14. Surface characterization of graphene based materials

    International Nuclear Information System (INIS)

    Pisarek, M.; Holdynski, M.; Krawczyk, M.; Nowakowski, R.; Roguska, A.; Malolepszy, A.; Stobinski, L.; Jablonski, A.

    2016-01-01

    Highlights: • Two kind of samples: commercial graphene on Cu substrate and rGO flakes. • EPES applied to measure the IMFPs in graphene based materials. • Characterization by various techniques like: FE-SEM, AFM, XPS, AES and REELS. • EPES IMFPs for rGO deviated up to 14% from IMFPs calculated using the optical data. - Abstract: In the present study, two kind of samples were used: (i) a monolayer graphene film with a thickness of 0.345 nm deposited by the CVD method on Cu foil, (ii) graphene flakes obtained by modified Hummers method and followed by reduction of graphene oxide. The inelastic mean free path (IMFP), characterizing electron transport in graphene/Cu sample and reduced graphene oxide material, which determines the sampling depth of XPS and AES were evaluated from relative Elastic Peak Electron Spectroscopy (EPES) measurements with the Au standard in the energy range 0.5–2 keV. The measured IMFPs were compared with IMFPs resulting from experimental optical data published in the literature for the graphite sample. The EPES IMFP values at 0.5 and 1.5 keV was practically identical to that calculated from optical data for graphite (less than 4% deviation). For energies 1 and 2 keV, the EPES IMFPs for rGO were deviated up to 14% from IMFPs calculated using the optical data by Tanuma et al. [1]. Before EPES measurements all samples were characterized by various techniques like: FE-SEM, AFM, XPS, AES and REELS to visualize the surface morphology/topography and identify the chemical composition.

  15. Surface characterization of graphene based materials

    Energy Technology Data Exchange (ETDEWEB)

    Pisarek, M., E-mail: mpisarek@ichf.edu.pl [Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland); Holdynski, M.; Krawczyk, M.; Nowakowski, R.; Roguska, A. [Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland); Malolepszy, A. [Faculty of Chemical and Process Engineering, Warsaw University of Technology, Warynskiego 1, 00-065 Warsaw (Poland); Stobinski, L. [Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland); Faculty of Chemical and Process Engineering, Warsaw University of Technology, Warynskiego 1, 00-065 Warsaw (Poland); Jablonski, A. [Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland)

    2016-12-01

    Highlights: • Two kind of samples: commercial graphene on Cu substrate and rGO flakes. • EPES applied to measure the IMFPs in graphene based materials. • Characterization by various techniques like: FE-SEM, AFM, XPS, AES and REELS. • EPES IMFPs for rGO deviated up to 14% from IMFPs calculated using the optical data. - Abstract: In the present study, two kind of samples were used: (i) a monolayer graphene film with a thickness of 0.345 nm deposited by the CVD method on Cu foil, (ii) graphene flakes obtained by modified Hummers method and followed by reduction of graphene oxide. The inelastic mean free path (IMFP), characterizing electron transport in graphene/Cu sample and reduced graphene oxide material, which determines the sampling depth of XPS and AES were evaluated from relative Elastic Peak Electron Spectroscopy (EPES) measurements with the Au standard in the energy range 0.5–2 keV. The measured IMFPs were compared with IMFPs resulting from experimental optical data published in the literature for the graphite sample. The EPES IMFP values at 0.5 and 1.5 keV was practically identical to that calculated from optical data for graphite (less than 4% deviation). For energies 1 and 2 keV, the EPES IMFPs for rGO were deviated up to 14% from IMFPs calculated using the optical data by Tanuma et al. [1]. Before EPES measurements all samples were characterized by various techniques like: FE-SEM, AFM, XPS, AES and REELS to visualize the surface morphology/topography and identify the chemical composition.

  16. Efficient waveguide coupler based on metal materials

    Science.gov (United States)

    Wu, Wenjun; Yang, Junbo; Chang, Shengli; Zhang, Jingjing; Lu, Huanyu

    2015-10-01

    Because of the diffraction limit of light, the scale of optical element stays in the order of wavelength, which makes the interface optics and nano-electronic components cannot be directly matched, thus the development of photonics technology encounters a bottleneck. In order to solve the problem that coupling of light into the subwavelength waveguide, this paper proposes a model of coupler based on metal materials. By using Surface Plasmon Polaritons (SPPs) wave, incident light can be efficiently coupled into waveguide of diameter less than 100 nm. This paper mainly aims at near infrared wave band, and tests a variety of the combination of metal materials, and by changing the structural parameters to get the maximum coupling efficiency. This structure splits the plane incident light with wavelength of 864 nm, the width of 600 nm into two uniform beams, and separately coupled into the waveguide layer whose width is only about 80 nm, and the highest coupling efficiency can reach above 95%. Using SPPs structure will be an effective method to break through the diffraction limit and implement photonics device high-performance miniaturization. We can further compress the light into small scale fiber or waveguide by using the metal coupler, and to save the space to hold more fiber or waveguide layer, so that we can greatly improve the capacity of optical communication. In addition, high-performance miniaturization of the optical transmission medium can improve the integration of optical devices, also provide a feasible solution for the photon computer research and development in the future.

  17. Oral manifestations of diabetes mellitus in complete denture wearers.

    Science.gov (United States)

    Cristina de Lima, Danielle; Nakata, Gislaine Cristina; Balducci, Ivan; Almeida, Janete Dias

    2008-01-01

    The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.

  18. Water vapor movement in freezing aggregate base materials.

    Science.gov (United States)

    2014-06-01

    The objectives of this research were to 1) measure the extent to which water vapor movement results in : water accumulation in freezing base materials; 2) evaluate the effect of soil stabilization on water vapor movement : in freezing base materials;...

  19. A study of dentists’ preferences for the restoration of shortened dental arches with partial dentures

    Science.gov (United States)

    Nassani, Mohammad Zakaria; Ibraheem, Shukran; Al-Hallak, Khaled Rateb; Ali El Khalifa, Mohammed Othman; Baroudi, Kusai

    2015-01-01

    Objective: This study aimed to use a utility method in order to assess dentists’ preferences for the restoration of shortened dental arches (SDAs) with partial dentures. Also, the impact of patient age and length of the SDA on dentists’ preferences for the partial dentures was investigated. Materials and Methods: Totally, 104 subjects holding a basic degree in dentistry and working as staff members in a private dental college in Saudi Arabia were interviewed and presented with 12 scenarios for patients of different ages and mandibular SDAs of varying length. Participants were asked to indicate on a standardized visual analog scale how they would value the health of the patient's mouth if the mandibular SDAs were restored with cobalt-chromium removable partial dentures (RPDs). Results: With a utility value of 0.0 representing the worst possible health state for a mouth and 1.0 representing the best, dentists’ average utility value of the RPD for the SDAs was 0.49 (sd= 0.15). Mean utility scores of the RPDs across the 12 SDA scenarios ranged between 0.35 and 0.61. RPDs that restored the extremely SDAs attracted the highest utility values and dentists’ utility of the RPD significantly increased with the increase in the number of missing posterior teeth. No significant differences in dentists’ mean utility values for the RPD were identified among SDA scenarios for patients of different ages. Conclusion: Restoration of the mandibular SDAs by RPDs is not a highly preferred treatment option among the surveyed group of dentists. Length of the SDA affects dentists’ preferences for the RPD, but patient age does not. PMID:26038647

  20. Evaluation of methods for stain removal in acrylic resin denture teeth: in vitro study

    Directory of Open Access Journals (Sweden)

    Ana Flávia Balestrero CASSIANO

    Full Text Available Abstract Introduction The staining of artificial teeth can be related to the acrylic resin abrasion caused by brushing, resulting in higher deposition of dyes from the beverage, and consequently higher aesthetic damage. Objective The aim of this in vitro study was to evaluate methods for removal of stains from acrylic denture teeth using spectrophotometric analysis. Material and method Artificial teeth were divided into twelve groups (n=10 according to the type of treatment (re-polishing - Re or immersion in Corega Tabs - Sp, staining solutions, coffee (Cf and Coca-Cola® (Cc or water (W and with/without toothbrushing (B. The Sp specimens were submitted to seven immersion cycles (5 min each. The Re specimens were polished with pumice stone followed by Spain white paste. Color differences (ΔE were captured by a spectrophotometer: T0 (baseline, T1 (after brushing/immersion in solutions and T2 (after Re or Sp. Result Statistically significant color change between T1 and T2 (paired T-test; α =.05 was observed for the group CfSp (p=.032; and for the groups BWRe (p=.000, BCfRe (p=.049 and CcRe (p=.042. Higher color changes were observed for the specimens submitted to toothbrushing (ANOVA two way; p<.001. Conclusion It could be concluded that the immersion in sodium perborate (Corega Tabs can be used for removal of coffee stains from denture teeth, and re-polishing for removal of Coca-Cola® stains. Still, toothbrushing produced greater color changes on denture teeth, regardless of the immersion solution.

  1. Isolation of Candida species from the oral cavity and fingertips of complete denture wearers.

    Science.gov (United States)

    Nagaral, Suresh; Desai, Raviraj G; Kamble, Vikas; Patil, Anand Kumar G

    2014-11-01

    Wearing a dental prosthesis is known to increase oral candidal colonization and predispose the wearer to oral candidosis. Denture wearers frequently use fingers to take the prosthesis out of their mouth. Oral Candida, if present may contaminate wearer's finger. The objective of this study was to investigate the simultaneous candidal colonization of oral cavity and fingertips of complete denture wearers. A total of 25 apparently healthy male subjects who had worn complete dentures for at least 1 year were selected. Information about each patient's denture age, denture hygiene, handling, and wearing habits, and hand washing habits after denture handling were be obtained. Intraoral examination of all the patients was done. For microbiological examination samples were collected from the fingertip and oral rinse of each patient. Candida species were identified with use of germ tube test and commercially available yeast identification system. Data was statistically analyzed. Significance was set at p < 0.05. It was found that frequency of hand washing, denture handling and denture stomatitis with respect to fingertip candidal isolation was not statistically significant. But poor denture hygiene and denture stomatitis with respect to oral candidal colonization was statistically significant. Denture wearers with oral Candida had a higher prevalence of Candida contamination on their fingers. Patients with removable prostheses should be informed about the importance of proper prosthesis and personal hygiene and the possibility of microbial contamination of the hands and other parts of the body.

  2. OVERLAY DENTURES: A REVIEW AND REPORT OF FOUR CASES

    Directory of Open Access Journals (Sweden)

    Deeksha SHARMA

    2013-12-01

    Full Text Available Patients with ectodermal dysplasia or having under‑ gone cleft surgery with anodontia or hypodontia, hypo‑ plastic conical teeth and patients with severely worn dentition are difficult to treat because of the poor remaining tooth structure. These patients often exhibit loss of vertical dimension of occlusion and aesthetic problems and usually need complex prosthetic treatments. Financial constraints or other priorities often restrict one from choosing the most desirable treatment. The overlay removable denture is a covering prosthesis partially supported by natural teeth, tooth roots, or dental implants, providing an efficient alter‑ native of treatment. Clinical reports describe the various applications of overlay dentures.

  3. Sustainable bio-based materials: opportunities and challenges

    NARCIS (Netherlands)

    van der Meer, Yvonne

    2017-01-01

    Research in the area of bio-based materials aims to achieve breakthroughs in bio-based materials development. A novel way is presented to organise bio-based materials research with a value chain approach in which sustainability research is integrated in the research program. This research approach

  4. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Science.gov (United States)

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  5. Materials And Processes Technical Information System (MAPTIS) LDEF materials data base

    Science.gov (United States)

    Funk, Joan G.; Strickland, John W.; Davis, John M.

    1993-01-01

    A preliminary Long Duration Exposure Facility (LDEF) Materials Data Base was developed by the LDEF Materials Special Investigation Group (MSIG). The LDEF Materials Data Base is envisioned to eventually contain the wide variety and vast quantity of materials data generated from LDEF. The data is searchable by optical, thermal, and mechanical properties, exposure parameters (such as atomic oxygen flux) and author(s) or principal investigator(s). Tne LDEF Materials Data Base was incorporated into the Materials and Processes Technical Information System (MAPTIS). MAPTIS is a collection of materials data which has been computerized and is available to engineers, designers, and researchers in the aerospace community involved in the design and development of spacecraft and related hardware. The LDEF Materials Data Base is described and step-by-step example searches using the data base are included. Information on how to become an authorized user of the system is included.

  6. Minicomputer based, controlled materials information system

    International Nuclear Information System (INIS)

    Roberts, N.; Jessen, T.; Meadors, O.; Seibel, D.

    1976-01-01

    The LLL, Materials Management Group and Data Processing Services have developed a transaction-oriented, minicomputer system for the management of the Laboratory's controlled materials. The system consists of a multi-vendor hardware system designed for ease of operation, maximum reliability, and quick response and the requirements imposed on the hardware and software systems are discussed

  7. Association between dentures and the rate of falls in dementia

    Directory of Open Access Journals (Sweden)

    Eshkoor SA

    2014-06-01

    Full Text Available Sima Ataollahi Eshkoor,1 Tengku Aizan Hamid,1 Siti Sa'adiah Hassan Nudin,2 Chan Yoke Mun11Institute of Gerontology, Universiti Putra Malaysia, Serdang, 2Institute for Behavioral Research, Kuala Lumpur, MalaysiaBackground: Poor oral health, chronic diseases, functional decline, and low cognitive ability can increase the risk of falls in the elderly.Objectives: The current study aimed to show the effects of oral health, diabetes mellitus (DM, hypertension (HT, heart disease, functional status, and sociodemographic factors on the risk of falls in elderly with dementia.Materials and methods: The sample comprised 1,210 Malaysian elderly who were demented and noninstitutionalized. This study was a national cross-sectional survey entitled “Determinants of Health Status among Older Malaysians”. The effects of age, ethnicity, sex differences, marital status, educational level, oral health, DM, HT, heart disease, and functional status on the risk of falls were evaluated. The multiple logistic regression model was used to estimate the effects of contributing variables on the risk of falls in samples.Results: The prevalence of falls was approximately 17% in subjects. It was found that age (odds ratio [OR] 1.02, non-Malay ethnicity (OR 1.66, heart disease (OR 1.92, and functional decline (OR 1.58 significantly increased the risk of falls in respondents (P<0.05. Furthermore, having teeth (OR 0.59 and dentures (OR 0.66 significantly decreased the rate of falls (P<0.05.Conclusion: It was concluded that age, non-Malay ethnicity, functional decline, heart disease, and oral health significantly affected falls in dementia.Keywords: chronic diseases, dementia, fall, functional decline, oral health

  8. Smart material-based radiation sources

    Science.gov (United States)

    Kovaleski, Scott

    2014-10-01

    From sensors to power harvesters, the unique properties of smart materials have been exploited in numerous ways to enable new applications and reduce the size of many useful devices. Smart materials are defined as materials whose properties can be changed in a controlled and often reversible fashion by use of external stimuli, such as electric and magnetic fields, temperature, or humidity. Smart materials have been used to make acceleration sensors that are ubiquitous in mobile phones, to make highly accurate frequency standards, to make unprecedentedly small actuators and motors, to seal and reduce friction of rotating shafts, and to generate power by conversion of either kinetic or thermal energy to electrical energy. The number of useful devices enabled by smart materials is large and continues to grow. Smart materials can also be used to generate plasmas and accelerate particles at small scales. The materials discussed in this talk are from non-centrosymmetric crystalline classes including piezoelectric, pyroelectric, and ferroelectric materials, which produce large electric fields in response to external stimuli such as applied electric fields or thermal energy. First, the use of ferroelectric, pyroelectric and piezoelectric materials for plasma generation and particle acceleration will be reviewed. The talk will then focus on the use of piezoelectric materials at the University of Missouri to construct plasma sources and electrostatic accelerators for applications including space propulsion, x-ray imaging, and neutron production. The basic concepts of piezoelectric transformers, which are analogous to conventional magnetic transformers, will be discussed, along with results from experiments over the last decade to produce micro-thrusters for space propulsion and particle accelerators for x-ray and neutron production. Support from ONR, AFOSR, and LANL.

  9. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners.

    Science.gov (United States)

    Fokkinga, Wietske A; van Uchelen, Judith; Witter, Dick J; Mulder, Jan; Creugers, Nico H J

    2016-01-01

    This pilot study analyzed impression procedures for conventional metal frame removable partial dentures (RPDs). Heads of RPD departments of three dental laboratories were asked to record features of all incoming impressions for RPDs during a 2-month period. Records included: (1) impression procedure, tray type (stock/custom), impression material (elastomer/alginate), use of border-molding material (yes/no); and (2) RPD type requested (distal-extension/tooth-bounded/combination). Of the 132 total RPD impressions, 111 (84%) involved custom trays, of which 73 (55%) were combined with an elastomer. Impression border-molding material was used in 4% of the cases. Associations between impression procedure and RPD type or dentists' year/university of graduation were not found.

  10. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    Science.gov (United States)

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture

  11. [Preface for special issue on bio-based materials (2016)].

    Science.gov (United States)

    Weng, Yunxuan

    2016-06-25

    Bio-based materials are new materials or chemicals with renewable biomass as raw materials such as grain, legume, straw, bamboo and wood powder. This class of materials includes bio-based polymer, biobased fiber, glycotechnology products, biobased rubber and plastics produced by biomass thermoplastic processing and basic biobased chemicals, for instance, bio-alcohols, organic acids, alkanes, and alkenes, obtained by bio-synthesis, bio-processing and bio-refinery. Owing to its environmental friendly and resource conservation, bio-based materials are becoming a new dominant industry taking the lead in the world scientific and technological innovation and economic development. An overview of bio-based materials development is reported in this special issue, and the industrial status and research progress of the following aspects, including biobased fiber, polyhydroxyalkanoates, biodegradable mulching film, bio-based polyamide, protein based biomedical materials, bio-based polyurethane, and modification and processing of poly(lactic acid), are introduced.

  12. Implant-supported removable partial dentures in the mandible

    NARCIS (Netherlands)

    Louwerse, Charlotte

    2017-01-01

    Conventional removable partial dentures (RPD) in a free-ending situation in the lower jaw (i.e. only front teeth left) have a poor reputation. Several problems like discomfort and functional problems are frequently encountered, resulting in dissatisfied patients and desperate dentists. By supporting

  13. Cytotoxicity of four denture adhesives on human gingival fibroblast cells.

    Science.gov (United States)

    Lee, Yoon; Ahn, Jin-Soo; Yi, Young-Ah; Chung, Shin-Hye; Yoo, Yeon-Jee; Ju, Sung-Won; Hwang, Ji-Yun; Seo, Deog-Gyu

    2015-02-01

    The purpose of this study was to compare the cytotoxicity of four denture adhesives on human gingival fibroblast cells. Immortalized human gingival fibroblasts were cultured with one of four different denture adhesives, Polident, Protefix, Staydent or Denfix-A, which was placed in insert dishes (10% w/v concentration) for 48 h. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and flow cytometric apoptosis assay were used to evaluate cell viability and apoptosis rates. The fibroblasts were also examined under a scanning electron microscope. The MTT assay showed that all denture adhesives resulted in a significantly lower cell viability compared to the control cells propagated in normal culture medium (p 0.05). Staydent showed the highest apoptosis rate. Scanning electron microscopy showed that the cells of the Staydent group underwent cytoplasmic membrane shrinkage, with cell free areas containing residual fragments of the membrane of dead cells. The four denture adhesives evaluated in this study imparted cytotoxic effects on human gingival fibroblast cells. Staydent showed the highest toxicity.

  14. Sectional removable partial denture design for the treatment of ...

    African Journals Online (AJOL)

    Sectional removable partial denture design for the treatment of partial mandibulectomy patient: a case report. ... mandibulectomy with no surgical reconstruction. The case was challenging and the prosthesis was well tolerated during a 6 months follow-up review. (Afr. J. Biomed. Res. 10: 197 - 201). Keywords: Removable ...

  15. The use of implants as retainers for removable partial dentures.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Shapiro, Herbert J

    2010-01-01

    There has been little presented in the literature regarding the use of implant bodies as retainers for removable partial dentures. However, these fixtures can be a useful asset for restorative dentists, as they can be used when there is insufficient bone for a fixed prosthesis or as retainers for a provisional appliance until additional dental treatment is possible.

  16. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  17. The preliminary Long Duration Exposure Facility (LDEF) materials data base

    International Nuclear Information System (INIS)

    Funk, J.G.; Strickland, J.W.; Davis, J.M.

    1992-10-01

    A preliminary Long Duration Exposure Facility (LDEF) Materials Data Base was developed by the LDEF Materials Special Investigation Group (MSIG). The LDEF Materials Data Base is envisioned to eventually contain the wide variety and vast quantity of materials data generated for LDEF. The data is searchable by optical, thermal, and mechanical properties, exposure parameters (such as atomic oxygen flux), and author(s) or principal investigator(s). The LDEF Materials Data Base was incorporated into the Materials and Processes Technical Information System (MAPTIS). MAPTIS is a collection of materials data which was computerized and is available to engineers, designers, and researchers in the aerospace community involved in the design and development of spacecraft and related hardware. This paper describes the LDEF Materials Data Base and includes step-by-step example searches using the data base. Information on how to become an authorized user of the system is included

  18. The preliminary Long Duration Exposure Facility (LDEF) materials data base

    Science.gov (United States)

    Funk, Joan G.; Strickland, John W.; Davis, John M.

    1992-01-01

    A preliminary Long Duration Exposure Facility (LDEF) Materials Data Base was developed by the LDEF Materials Special Investigation Group (MSIG). The LDEF Materials Data Base is envisioned to eventually contain the wide variety and vast quantity of materials data generated for LDEF. The data is searchable by optical, thermal, and mechanical properties, exposure parameters (such as atomic oxygen flux), and author(s) or principal investigator(s). The LDEF Materials Data Base was incorporated into the Materials and Processes Technical Information System (MAPTIS). MAPTIS is a collection of materials data which was computerized and is available to engineers, designers, and researchers in the aerospace community involved in the design and development of spacecraft and related hardware. This paper describes the LDEF Materials Data Base and includes step-by-step example searches using the data base. Information on how to become an authorized user of the system is included.

  19. Supercapacitors based on graphene/pseudocapacitive materials

    OpenAIRE

    Sačer Denis; Kralj Magdalena; Sopčić Suzana; Košević Milica; Dekanski Aleksandar; Roković-Kraljić Marijana

    2017-01-01

    Composites of graphene and SnO2 were successfully prepared by a single step simultaneous synthesis of SnO2 and reduction of graphene oxide (GO). Three different compositions of precursor solution resulted in different composite materials containing graphene and SnO2. The reaction was realized by microwave-assisted hydrothermal synthesis. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) gave insight into the morphology and composition of the obtained materials....

  20. Microfiber devices based on carbon materials

    OpenAIRE

    Gengzhi Sun; Xuewan Wang; Peng Chen

    2015-01-01

    Microfiber devices are able to extend the micro/nano functionalities of materials or devices to the macroscopic scale with excellent flexibility and weavability, promising a variety of unique applications and, sometimes, also improved performance as compared with bulk counterparts. The fiber electrodes in these devices are often made of carbon materials (e.g. carbon nanotubes and graphene) because of their exceptional electrical, mechanical, and structural properties. Covering the latest deve...

  1. Biodegradable starch-based polymeric materials

    Science.gov (United States)

    Suvorova, Anna I.; Tyukova, Irina S.; Trufanova, Elena I.

    2000-05-01

    The effects of low-molecular-weight additives, temperature and mechanical action on the structure and properties of starch are discussed. Special attention is given to mixtures of starch with synthetic polymers, e.g., co-polymers of ethylene with vinyl acetate, vinyl alcohol, acrylic acid, cellulose derivatives and other natural polymers. These mixtures can be used in the development of novel environmentally safe materials (films, coatings, packaging materials) and various articles for short-term use. The bibliography includes 105 references.

  2. Three Dimensional Finite Element Analysis of Distal Abutment Stresses of Removable Partial Dentures with Different Retainer Designs

    Science.gov (United States)

    Zarrati, Simindokht; Heidari, Fatemeh; Kashani, Jamal

    2015-01-01

    Objectives: This finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (RPDs) and the same RPD abutment tooth (not isolated). Materials and Methods: A Kennedy Class 1, modification 1 RPD framework was simulated on a 3D model of mandible with three different designs: an isolated tooth with a mesial rest, an isolated tooth with mesial and distal rests and an abutment with a mesial rest (which was not isolated); 26 N occlusal forces were exerted bilaterally on the first molar sites. Stress on the abutment teeth was analyzed using Cosmos Works 2009 Software. Results: In all designs, the abutment tooth stress concentration was located in the buccal alveolar crest. In the first model, the von Mises stress distribution in the contact area of I-bar clasp and cervical portion of the tooth was 19 MPa and the maximum stress was 30 MPa. In the second model, the maximum von Mises stress distribution was 15 MPa in the cervical of the tooth. In the third model, the maximum von Mises stress was located in the cervical of the tooth and the distal proximal plate. Conclusion: We recommend using both mesial and distal rests on the distal abutment teeth of distal extension RPDs. The abutment of an extension base RPD, which is not isolated in presence of its neighboring more anterior tooth, may have a better biomechanical prognosis. PMID:26884772

  3. Finite element analysis and clinical complications in mandibular implant-overdentures opposing maxillary dentures.

    Science.gov (United States)

    Khuder, Tameem; Yunus, Norsiah; Sulaiman, Eshamsul; Dabbagh, Ali

    2017-11-01

    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  5. The effect of denture adhesives on Candida albicans growth in vitro.

    Science.gov (United States)

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  6. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age

    Directory of Open Access Journals (Sweden)

    Bharathi Prakash

    2015-01-01

    Full Text Available Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud′s dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.

  7. The effect of a commercial probiotic drink on oral microbiota in healthy complete denture wearers

    Directory of Open Access Journals (Sweden)

    Justyna Sutula

    2012-10-01

    Full Text Available Background : It is acknowledged that oral and general health status declines with age. The global population of denture wearers is increasing, so is the incidence of denture biofilm-related problems, such as denture-associated stomatitis, aspiration pneumonia and malodour. It has been suggested that consumption of probiotic bacteria may improve oral health. However, the effects of probiotics on the oral microbiota of denture wearers have received little attention. Methods : The aim of this study was to investigate the effect of consumption of a commercial probiotic product (Yakult on microbiota of saliva, tongue and denture biofilm in healthy complete denture wearers. Eight healthy complete denture-wearing National Health Service (NHS patients undertook a 7-week trial comprising three phases: baseline; 4-week consumption of one bottle of Yakult per day, each containing a minimum 6.5×109 viable cells of Lactobacillus casei strain Shirota (LcS; 4-week washout period. The microbial viability and composition of saliva, tongue dorsum coating and denture biofilm were assessed using a range of solid selective and indicator media. Questionnaires were used to explore participants’ denture cleaning habits and impact of wearing dentures on their life quality and well-being [modified oral health impact profile (OHIP-14] prior to and after the study. Results : Seven volunteers (1 male, 6 females completed the trial. LcS temporarily colonised oral cavity and denture surface. There was no significant change in the viability of Streptococcus mutans, acidogenic microorganisms, total anaerobic species and Gram-negative obligate anaerobes between study phases. There was no obvious effect of LcS on occurrence and viability of Candida. Participants presented a good general knowledge of denture hygiene and their responses to OHIP-14 questionnaires improved after completing the study (p=0.16. Conclusion : It appeared that 4-week consumption of probiotic drink had

  8. Supercapacitors based on graphene/pseudocapacitive materials

    Directory of Open Access Journals (Sweden)

    Sačer Denis

    2017-01-01

    Full Text Available Composites of graphene and SnO2 were successfully prepared by a single step simultaneous synthesis of SnO2 and reduction of graphene oxide (GO. Three different compositions of precursor solution resulted in different composite materials containing graphene and SnO2. The reaction was realized by microwave-assisted hydrothermal synthesis. Scanning electron microscopy (SEM and energy-dispersive X-ray spectroscopy (EDX gave insight into the morphology and composition of the obtained materials. Good capacitive/pseudocapacitive properties of the obtained material suitable for supercapacitor application were registered by cyclic voltammetry, from where specific capacitance values up to 93 F g-1 were determined. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 172060

  9. Design and evaluation of foamed asphalt base materials.

    Science.gov (United States)

    2013-05-01

    Foamed asphalt stabilized base (FASB) combines reclaimed asphalt pavement (RAP), recycled : concrete (RC), and/or graded aggregate base (GAB) with a foamed asphalt binder to produce a : partially stabilized base material. The objectives of this study...

  10. Material recognition based on thermal cues: Mechanisms and applications.

    Science.gov (United States)

    Ho, Hsin-Ni

    2018-01-01

    Some materials feel colder to the touch than others, and we can use this difference in perceived coldness for material recognition. This review focuses on the mechanisms underlying material recognition based on thermal cues. It provides an overview of the physical, perceptual, and cognitive processes involved in material recognition. It also describes engineering domains in which material recognition based on thermal cues have been applied. This includes haptic interfaces that seek to reproduce the sensations associated with contact in virtual environments and tactile sensors aim for automatic material recognition. The review concludes by considering the contributions of this line of research in both science and engineering.

  11. Wheat B-starch based polymeric materials

    Czech Academy of Sciences Publication Activity Database

    Kotek, Jiří; Kruliš, Zdeněk; Šárka, E.

    2011-01-01

    Roč. 105, č. 9 (2011), s. 731 ISSN 0009-2770. [International Conference on Polysaccharides-Glycoscience /7./. 02.11.2011-04.11.2011, Prague] R&D Projects: GA ČR GA525/09/0607 Institutional research plan: CEZ:AV0Z40500505 Keywords : biodegradable plastic * polycaprolactone * B- starch Subject RIV: JI - Composite Materials

  12. Acetylene-Based Materials in Organic Photovoltaics

    Directory of Open Access Journals (Sweden)

    Fabio Silvestri

    2010-04-01

    Full Text Available Fossil fuel alternatives, such as solar energy, are moving to the forefront in a variety of research fields. Organic photovoltaic systems hold the promise of a lightweight, flexible, cost-effective solar energy conversion platform, which could benefit from simple solution-processing of the active layer. The discovery of semiconductive polyacetylene by Heeger et al. in the late 1970s was a milestone towards the use of organic materials in electronics; the development of efficient protocols for the palladium catalyzed alkynylation reactions and the new conception of steric and conformational advantages of acetylenes have been recently focused the attention on conjugated triple-bond containing systems as a promising class of semiconductors for OPVs applications. We review here the most important and representative (polyarylacetylenes that have been used in the field. A general introduction to (polyarylacetylenes, and the most common synthetic approaches directed toward making these materials will be firstly given. After a brief discussion on working principles and critical parameters of OPVs, we will focus on molecular arylacetylenes, (copolymers containing triple bonds, and metallopolyyne polymers as p-type semiconductor materials. The last section will deal with hybrids in which oligomeric/polymeric structures incorporating acetylenic linkages such as phenylene ethynylenes have been attached onto C60, and their use as the active materials in photovoltaic devices.

  13. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study

    Directory of Open Access Journals (Sweden)

    Abhishek Shekhar

    2018-01-01

    Conclusions: Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  14. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    Science.gov (United States)

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  15. SECTIONAL MANDIBULAR COMPLETE DENTURE FOR A TOTAL MAXILLECTOMY PATIENT WITH TRISMUS: A CLINICAL REPORT

    Directory of Open Access Journals (Sweden)

    Tamer ÇELAKIL

    2017-10-01

    Full Text Available This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  16. Effect of Incorporation of Antifungal Agents on the Ultimate Tensile Strength of Temporary Soft Denture Liners.

    Science.gov (United States)

    Neppelenbroek, Karin Hermana; Lima, Jozely Francisca Mello; Hotta, Juliana; Galitesi, Lucas Lulo; Almeida, Ana Lucia Pompéia Fraga; Urban, Vanessa Migliorini

    2018-02-01

    To investigate the ultimate tensile strength of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314) determined in previous microbiological research. Dumbbell-shaped specimens (n = 7) with a central cross-sectional area of 6 × 3 × 33 mm were produced by Softone and Trusoft, without (control) or with incorporation of drugs in powder form at MICs for C. albicans biofilm (per g of material powder): nystatin (0.032 g), chlorhexidine diacetate (0.064 g), ketoconazole (0.128 g), miconazole (0.256 g), and itraconazole (0.256 g). After plasticization, specimens were immersed in distilled water at 37°C for 24 hours, 7 or 14 days, and then tested in tension in a universal testing machine at 40 mm/min. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA and Tukey's test (α = 0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (p 0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials resulted in significantly lower elongation percentages compared to the other antifungal agents and control (p 0.05). The addition of the nystatin, chlorhexidine, and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the tensile strength and elongation percentage of the temporary soft denture liner materials up to 14 days. © 2017 by the American College of Prosthodontists.

  17. Patients with burning mouth sensations. A clinical investigation of causative factors in a group of "compete denture wearers" Jordanian population.

    Science.gov (United States)

    Mukatash-Nimri, Gadeer Elea; Al-Nimri, Marwan A; Al-Jadeed, Omar G; Al-Zobe, Zaid R; Aburumman, Khuzama K; Masarwa, Nader A

    2017-01-01

    To find out the prevalence of "true" burning mouth syndrome and study the association between patients' spontaneous complaints of burning mouth and systemic conditions in a group of middle age and elderly "denture wearers" patients in Jordan. A group of 129 patients (112 female and 17 male) of "complete denture wearers" subjects aged 40 years and over attended prosthetic clinic at King Hussein Medical Hospital complaining from oral burning, with no oral lesion possibly responsible for the burning sensations were selected. Assessment of oral and general status was done based on questioners, detailed history taking, medical records and extra and intraoral examination. The existed complete dentures retention, stability, jaw relationship and the free way space were evaluated. The current blood test and instrumental protocol for examination of patients with burning mouth complains were performed for each patient. Then those studied patients with burning mouth sensations including "true" burning mouth syndrome have been compared to the controls with regard to the presence of local problem, undermined local, systemic or psychological disease. The diagnosis of "true" burning mouth syndrome was established in (2.3%) of the studied population two females and one male. In most patients (58%) more than one site was affected. Significant positive associations were found between local factors (i.e., wearing complete dentures with unsatisfactory retention or jaw relationship, dry mouth or candidasis) and patients suffering from burning mouth sensation. The results also show that some systemic or psychological disorders were significantly more present among patients with burning mouth symptoms when compared to the control group ( p  burning mouth without mucosal signs should be considered as a manifestation of undermind pathology and/or distress, and the multi-factorial causes of burning mouth syndrome and sensation need to be referred to the suitable specialist for better

  18. Reinforcement of Conducting Silver-based Materials

    Directory of Open Access Journals (Sweden)

    Heike JUNG

    2014-09-01

    Full Text Available Silver is a well-known material in the field of contact materials because of its high electrical and thermal conductivity. However, due to its bad mechanical and switching properties, silver alloys or reinforcements of the ductile silver matrix are required. Different reinforcements, e. g. tungsten, tungsten carbide, nickel, cadmium oxide or tin oxide, are used in different sectors of switches. To reach an optimal distribution of these reinforcements, various manufacturing techniques (e. g. powder blending, preform infiltration, wet-chemical methods, internal oxidation are being used for the production of these contact materials. Each of these manufacturing routes offers different advantages and disadvantages. The mechanical alloying process displays a successful and efficient method to produce particle-reinforced metal-matrix composite powders. This contribution presents the obtained fine disperse microstructure of tungsten-particle-reinforced silver composite powders produced by the mechanical alloying process and displays this technique as possible route to provide feedstock powders for subsequent consolidation processes. DOI: http://dx.doi.org/10.5755/j01.ms.20.3.4889

  19. A comparative study for plaque removing efficacy between commonly used denture cleansers in India

    Directory of Open Access Journals (Sweden)

    Bhushan Kumar

    2017-01-01

    Conclusions: There was no significant difference among action of four denture cleansers used in this study. Thus we can infer that patients can use liquid handwashing soap or commercial products to overcome disadvantages of toothpastes. Recommendation from the results of this study is the use of liquid handwashing soap for cleansing after every meal and soaking of the denture in commercial denture cleanser during the night.

  20. Materials data base as an interface between fusion reactor designs and materials development

    International Nuclear Information System (INIS)

    Ishino, S.; Iwata, S.

    1983-01-01

    The materials data base is an integrated information system of experimental and/or calculated data of materials being compiled to meet the broad needs for materials data by taking advantage of the data base management systems. In this paper the objective of such computerized data base is described from the viewpoint of materials engineers and fusion system designers. Materials data spread themselves widely from the field that relates fundamental understanding of the behaviors of electrons, atoms, vacancies, dislocations and so on to the performance of components, devices, machines and systems. In our approach this information is described as ''relations'' by a set of tables which comprise related variables, for example, a set of values about essential properties for materials selection. This approach based on the relational model enables relational operations, i.e. SELECTION, PROJECTION, JOIN and so on, to select suitable materials, to set trade-off parameters for system designers and to establish design criteria. Stored data comprise (i) fundamental properties for all elements and potential structural materials, (ii) low cycle fatigue, irradiation creep and swelling data for type 316 stainless steels. These data have been selected and evaluated from critical reviews of existing data base of about 2 mega bytes data, some examples of materials selections and extraction of trade-off parameters are shown as a subject of critical issue concerning how to bridge the large gap between materials developments and system designs. (author)

  1. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Science.gov (United States)

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  2. Diatom-Based Material Production Demonstration

    Science.gov (United States)

    2016-03-14

    Haeger 0.02 Sean Hoban 0.05 Leila Kamakele 0.06 Jeff Kataoka 0.08 Randi Keipper 0.16 Brendan Lagather 0.17 Stephen Woods 0.10 Rodney Corpuz 0.13 Aga...to Cathleen Fischer at Dresden University of Technology for testing as a substrate for catalysis. Material is available for any other testing...also thank Dr. Pat Kociolek from University of Colorado for help with identifying girdle bands of GAI-216. Bibliography Jantschke A., C. Fischer

  3. Future perspectives of resin-based dental materials.

    Science.gov (United States)

    Jandt, Klaus D; Sigusch, Bernd W

    2009-08-01

    This concise review and outlook paper gives a view of selected potential future developments in the area of resin-based biomaterials with an emphasis on dental composites. A selection of key publications (1 book, 35 scientific original publications and 1 website source) covering the areas nanotechnology, antimicrobial materials, stimuli responsive materials, self-repairing materials and materials for tissue engineering with direct or indirect relations and/or implications to resin-based dental materials is critically reviewed and discussed. Connections between these fields and their potential for resin-based dental materials are highlighted and put in perspective. The need to improve shrinkage properties and wear resistance is obvious for dental composites, and a vast number of attempts have been made to accomplish these aims. Future resin-based materials may be further improved in this respect if, for example nanotechnology is applied. Dental composites may, however, reach a completely new quality by utilizing new trends from materials science, such as introducing nanostructures, antimicrobial properties, stimuli responsive capabilities, the ability to promote tissue regeneration or repair of dental tissues if the composites were able to repair themselves. This paper shows selected potential future developments in the area of resin-based dental materials, gives basic and industrial researchers in dental materials science, and dental practitioners a glance into the potential future of these materials, and should stimulate discussion about needs and future developments in the area.

  4. Effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force: A preliminary cross over study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Mostafa, Aisha Zakaria

    2018-01-01

    This cross over study aimed to evaluate the effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force MATERIALS AND METHODS: Twenty patients with complete maxillary edentulism and partially edentulous mandibles with anterior teeth only remaining were selected for this cross over study. All patients received complete maxillary dentures and mandibular partial removable dental prosthesis (PRDP, control). After 3 months of adaptation, PRDP was replaced with conventional telescopic partial dentures (TPD) or telescopic partial dentures with cantilevered extensions (TCPD) in a quasi-random method. Oral health related quality of life (OHRQoL) was measured using OHIP-14 questionnaire and Maximum bite force (MBF) was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses; PRDP, TPD, and TCPD. TCPD showed the OHIP-14 lowest scores (i.e., the highest patient satisfaction with their OHRQoL), followed by TPD, and PRDP showed the highest OHIP-14 scores (i.e., the lowest patient satisfaction with OHRQoL). TCPD showed the highest MBF (70.7 ± 3.71), followed by TPD (57.4 ± 3.43) and the lowest MBF (40.2 ± 2.20) was noted with PRDP. WITHIN The Limitations of This Study, Mandibular Telescopic Distal Extension Removable Partial Dentures with Cantilevered Extensions Were Associated with Improved Oral Health Related Quality of Life and Maximum Bite Force Compared to Telescopic or Conventional PRDP. Telescopic distal extension removable prostheses is an esthetic restoration in partially edentulous patients with free end saddle. This article describes the addition of cantilevered extensions of this prosthesis. The results showed that telescopic distal extension removable prostheses with cantilevered extensions were associated with improved oral health related quality of life and maximum bite force compared to telescopic or conventional RPDs

  5. Evaluation of oral stereognostic ability after rehabilitating patients with complete dentures: in vivo study.

    Science.gov (United States)

    Meenakshi, S; Gujjari, Anil Kumar; Thippeswamy, H N; Raghunath, N

    2014-12-01

    Stereognosis has been defined as the appreciation of the form of objects by palpation. Whilst this definition holds good for the manual exploration of objects, it is possible for the shape of objects to be explored intra orally referred to as oral stereognosis. To better understand patients' relative satisfaction with complete dentures, differences in oral stereognostic perception, based on the identification of 6 edible objects was analyzed in a group of 30 edentulous individuals at 3 stages, namely, just before (pre-treatment), 30 min after (30 min post-treatment) and 1 month after (1 month post-treatment) the insertion of new dentures. The time required to identify each object was recorded and the correctness of identification of each object was scored using oral stereognostic score. Descriptive statistics, Wilcoxon signed rank test, Spearman's rank correlation test, Pearson Chi square test was used to statistically analyze the data obtained. OSA scores was significantly increased 1 month post-treatment compared to 30 min post-treatment (p < 0.05). It was found that Oral stereognostic test is reliable for measuring patients' oral stereognostic perception and may be used as one of the clinical aids in appreciating the functional limitations imposed by the prostheses.

  6. Connection of functional quality of partial removable dentures and the degree of patients' phonetic adaptation.

    Science.gov (United States)

    Artjomenko, Victoria; Vidzis, Aldis; Zigurs, Guntis

    2015-01-01

    Phonetic adaptation is a complex biological phenomenon with a highly individual course, depending on the patient's motivation to use prosthesis, on the functional quality of removable dentures. The aim of the study was to estimate phonetic adaptation in patients with partial dentures, connecting it to alteration in speech quality and dentures functional value. We examined some peculiarities of phonetic adaptation in 50 patients with removable dentures (50 patients with natural dentition were invited for the control group). The standardized evaluation protocols (12 speech quality determining parameters) were developed separately for Latvian and Russian native speakers. 500 speech video samples were recorded and analysed according to pre-established guidelines. The connection of speech quality and the functional quality of the dentures was assessed. Statistical analysis was performed using SPSS 20.0. P values equal to or less than 0.05 were considered to be statistically significant. In patients with appropriate functional quality of removable dentures distorted speech production was detected in 25% (pk=0.008) cases and in patients with inappropriate functional quality of the prosthesis - in 40% (pkdentures functional value were satisfied with their speech performance in 96% (pk=0.674), in the group with inappropriate dentures functional value only 59% (premovable dentures depends on the patient's individual adaptation capacity, prosthetic design and functional value. Thus statistically significant correlation between removable partial dentures functional value, duration of usage and the degree of patients' phonetic adaptation (p<0.001) may be considered to be confirmed.

  7. [Longitudinal survey and analysis among Chengdu residents on cognition and acceptance of implant dentures].

    Science.gov (United States)

    Zuo, Yanping; Wang, Yongyue; Wang, Luming; Du, Bing

    2014-08-01

    This study aims to survey the cognition and acceptance of implant dentures among Chengdu residents in 2005 and 2013 and to comparatively analyze the differences and influencing factors. A questionnaire was designed for this study. Its main content included basic demographics of respondents (gender, age, cultural level, and income level), cognition level of implant dentures (concept and main characteristics of implant dentures), main concern of respondents regarding implant dentures and medical institutions, and acceptance level of the price of implant dentures, among others. The sampling survey was carried out among Chengdu residents in 2005 and 2013 using the designed questionnaire. The results were then statistically analyzed. Up to 908 valid questionnaires in 2005 and 905 valid questionnaires in 2013 were obtained. The level of cognition of implant dentures was higher in 2013 than in 2005, and the correlation between cognition and cultural level and that between cognition and income level were both positive. However, the correlation between cognition and age was negative. The success rate for implant dentures and medical treatment technology of medical institutions were the factors that the respondents were mainly concerned with. The main methods for disseminating information on implant dentures were the internet, television, newspapers, magazines, and introduction by friends. With the development of the society's economy and the improvement of culture and income level of Chengdu residents, the cognition and acceptance level of implant dentures have gradualy increased. Meanwhile, health education and medical technology still need to be strengthened.

  8. The effect of various factors on the masticatory performance of removable denture wearer

    Science.gov (United States)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  9. All-Metallic Vertical Transistors Based on Stacked Dirac Materials

    OpenAIRE

    Wang, Yangyang; Ni, Zeyuan; Liu, Qihang; Quhe, Ruge; Zheng, Jiaxin; Ye, Meng; Yu, Dapeng; Shi, Junjie; Yang, Jinbo; Lu, Jing

    2014-01-01

    It is an ongoing pursuit to use metal as a channel material in a field effect transistor. All metallic transistor can be fabricated from pristine semimetallic Dirac materials (such as graphene, silicene, and germanene), but the on/off current ratio is very low. In a vertical heterostructure composed by two Dirac materials, the Dirac cones of the two materials survive the weak interlayer van der Waals interaction based on density functional theory method, and electron transport from the Dirac ...

  10. Advanced three dimensional characterization of silica-based ultraporous materials

    OpenAIRE

    Foray , Genevieve; Roiban , L.; Rong , Q.; Perret , A.; Ihiawakrim , D.; Masenelli-Varlot , K.; Maire , E.; Yrieix , B.

    2016-01-01

    International audience; Whatever the field of application (building, transportation, packaging, etc.) energy losses must be reduced to meet the government target of a 40% cut in CO 2 emissions. This leads to a challenge for materials scientists: designing materials with thermal conductivities lower than 0.015 W m À1 K À1 under ambient conditions. Such a low value requires reducing air molecule mobility in highly porous materials, and silica-based superinsulation materials (SIM) made of packed...

  11. Materials data base for fusion reactors-I

    International Nuclear Information System (INIS)

    Iwata, S.; Nogami, A.; Ishino, S.; Mishima, Y.; Takao, Y.; Aruga, T.; Shiraishi, K.

    1982-01-01

    The materials data base is a set of experimental and/or calculated data being compiled to meet the broad needs for materials data by taking advantage of the data base management systems. In this paper the objective of such computerized data base is described and the characteristics of fusion reactor materials are discussed from the viewpoint of the data base development. The near-term emphasis of the development has been put on the irradiation data for 316 type stainless steels. Through the test of this small data base, it can be concluded that this approach is promising for materials data base management and for the establishment of the interface between fusion reactor designer and materials investigator. (orig.)

  12. Intermetallic-Based High-Temperature Materials

    Energy Technology Data Exchange (ETDEWEB)

    Sikka, V.K.

    1999-04-25

    The intermetallic-based alloys for high-temperature applications are introduced. General characteristics of intermetallics are followed by identification of nickel and iron aluminides as the most practical alloys for commercial applications. An overview of the alloy compositions, melting processes, and mechanical properties for nickel and iron aluminizes are presented. The current applications and commercial producers of nickel and iron aluminizes are given. A brief description of the future prospects of intermetallic-based alloys is also given.

  13. Protein-Based Drug-Delivery Materials

    OpenAIRE

    Jao, Dave; Xue, Ye; Medina, Jethro; Hu, Xiao

    2017-01-01

    There is a pressing need for long-term, controlled drug release for sustained treatment of chronic or persistent medical conditions and diseases. Guided drug delivery is difficult because therapeutic compounds need to survive numerous transport barriers and binding targets throughout the body. Nanoscale protein-based polymers are increasingly used for drug and vaccine delivery to cross these biological barriers and through blood circulation to their molecular site of action. Protein-based pol...

  14. Modern materials based on refractory compounds

    International Nuclear Information System (INIS)

    Kosolapova, T.Ya.

    1979-01-01

    Discussed are the existing methods for synthesizing powders of binary refractory compounds and high-productivity techniques which hold promise as regards the manufacture of highly disperse and pure powders. Plasmochemical synthesis is shown to be an effective method for obtaining practically all carbides, nitrides and borides. A description is given of three main methods for obtaining single crystals of refractory compounds (TiN, TiC, ZrC, ZrB 2 , NbC) fairly perfect in structure and composition. These processes include deposition from vapour-gas phase, melting in arc plasma and crystallization from solutions in metallic melts. The advantages have been shown of the self-propagating high-temperature synthesis of refractory compounds, ensuring the manufacture of products, close in composition to stoichiometric ones simultaneously with forming of items. Mechanical, thermal, abrasive, and resistive characteristics of the above materials are presented

  15. [Current status of bio-based materials industry in China].

    Science.gov (United States)

    Diao, Xiaoqian; Weng, Yunxuan; Huang, Zhigang; Yang, Nan; Wang, Xiyuan; Zhang, Min; Jin, Yujuan

    2016-06-25

    In recent years, bio-based materials are becoming a new dominant industry leading the scientific and technological innovation, and economic development of the world. We reviewed the new development of bio-based materials industry in China, analyzed the entire market of bio-based materials products comprehensively, and also stated the industry status of bio-based chemicals, such as lactic acid, 1,3-propanediol, and succinic acid; biodegradable bio-based polymers, such as co-polyester of diacid and diol, polylactic acid, carbon dioxide based copolymer, polyhydroxyalknoates, polycaprolactone, and thermoplastic bio-based plastics; non-biodegradable bio-based polymers, such as bio-based polyamide, polytrimethylene terephthalate, bio-based polyurethane, and bio-based fibers.

  16. Ti-Ni-based shape memory alloys as smart materials

    International Nuclear Information System (INIS)

    Otsuka, K.; Xu, Y.; Ren, X.

    2003-01-01

    Smart materials consist of three principal materials, ferroelectrics, shape memory alloys (SMA) and electro-active polymers (EAP). Among these SMAs, especially Ti-Ni-based alloys are important, since only they can provide large recoverable strains and high recovery stress. In the present paper the unique characteristics of Ti-Ni-based shape memory alloys are reviewed on an up-to-date basis with the aim of their applications to smart materials and structures. (orig.)

  17. Listener: a probe into information based material specification

    DEFF Research Database (Denmark)

    Ramsgaard Thomsen, Mette; Karmon, Ayelet

    2011-01-01

    This paper presents the thinking and making of the architectural research probe Listener. Developed as an interdisciplinary collaboration between textile design and architecture, Listener explores how information based fabrication technologies are challenging the material practices of architecture....... The paper investigates how textile design can be understood as a model for architectural production providing new strategies for material specification and allowing the thinking of material as inherently variegated and performative. The paper traces the two fold information based strategies present...

  18. Gingival Necrosis Caused by an Ill-Fitting Denture

    Directory of Open Access Journals (Sweden)

    Vanja VUČIĆEVIĆ BORAS

    2014-01-01

    Full Text Available We present a case of an 80-year-old male who was referred to the Department of Oral Medicine, School of Dental Medicine University of Zagreb, Croatia due to gingival ulcer which was present for eight days. Clinical examination has revealed exposed bone on the toothless alveolar ridge in the lower molar region on the right side of 0.8 cm in diameter. Otherwise, the patient was taking doxazosin due to urinary problems and ipatropium bromide due to respiratory problems. The patient wore a 6-year-old partial lower denture. He was initially treated with periodontal bandage (Resopack, HagenWerken, Germany for the first three days and was instructed not to wear the denture; however, no benefit could be seen. Therefore, we added a local corticosteroid (betamethasone and an oral antiseptic (chlorhexidine digluconate applied three times a day. After 3 weeks the lesion healed. A list of possible causative factors regarding gingival ulcers is included.

  19. Densified ultra-light cement-based materials

    DEFF Research Database (Denmark)

    Esteves, Luis Pedro

    2015-01-01

    be used as a “clean technology” in the production of cement-based materials for structural applications with a low carbon footprint. This paper describes the principles of this concept coupled with experimental results on the basic properties of this enhanced type of cement-based materials with combined...

  20. Development of bio-hybrid material based on Salmonella ...

    African Journals Online (AJOL)

    The immobilization of a whole microbial cell is an important process used in nanotechnology of biosensors and other related fields, especially the development of bio-hybrid materials based on live organisms and inorganic compounds. Here, we described an essay to develop a bio-hybrid material based on Salmonella ...

  1. Graphene-based materials for flexible supercapacitors.

    Science.gov (United States)

    Shao, Yuanlong; El-Kady, Maher F; Wang, Lisa J; Zhang, Qinghong; Li, Yaogang; Wang, Hongzhi; Mousavi, Mir F; Kaner, Richard B

    2015-06-07

    The demand for flexible/wearable electronic devices that have aesthetic appeal and multi-functionality has stimulated the rapid development of flexible supercapacitors with enhanced electrochemical performance and mechanical flexibility. After a brief introduction to flexible supercapacitors, we summarize current progress made with graphene-based electrodes. Two recently proposed prototypes for flexible supercapacitors, known as micro-supercapacitors and fiber-type supercapacitors, are then discussed. We also present our perspective on the development of graphene-based electrodes for flexible supercapacitors.

  2. Catalysis and Downsizing in Mg-Based Hydrogen Storage Materials

    Directory of Open Access Journals (Sweden)

    Jianding Li

    2018-02-01

    Full Text Available Magnesium (Mg-based materials are promising candidates for hydrogen storage due to the low cost, high hydrogen storage capacity and abundant resources of magnesium for the realization of a hydrogen society. However, the sluggish kinetics and strong stability of the metal-hydrogen bonding of Mg-based materials hinder their application, especially for onboard storage. Many researchers are devoted to overcoming these challenges by numerous methods. Here, this review summarizes some advances in the development of Mg-based hydrogen storage materials related to downsizing and catalysis. In particular, the focus is on how downsizing and catalysts affect the hydrogen storage capacity, kinetics and thermodynamics of Mg-based hydrogen storage materials. Finally, the future development and applications of Mg-based hydrogen storage materials is discussed.

  3. Use of a complete denture as a radiation carrier

    International Nuclear Information System (INIS)

    Herring, H.W. Jr.; Greene, P.E.

    1983-01-01

    When surgical resection of intraoral neoplasms is contraindicated, treatment by surface mold irradiation may be used. Success or failure of this mode of treatment may depend on the fabrication of a surface mold that can deliver the prescribed amount of therapeutic radiation in the desired amount of time. A technique for modification of an existing complete denture prosthesis for use as a surface mold has been described. Patient cooperation is essential for successful use of this modified prosthesis

  4. Functional Impressions in Complete Denture and Overdenture Treatment

    OpenAIRE

    Hrvoje Kršek; Nikša Dulčić

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fab...

  5. Surface characterization of graphene based materials

    Science.gov (United States)

    Pisarek, M.; Holdynski, M.; Krawczyk, M.; Nowakowski, R.; Roguska, A.; Malolepszy, A.; Stobinski, L.; Jablonski, A.

    2016-12-01

    In the present study, two kind of samples were used: (i) a monolayer graphene film with a thickness of 0.345 nm deposited by the CVD method on Cu foil, (ii) graphene flakes obtained by modified Hummers method and followed by reduction of graphene oxide. The inelastic mean free path (IMFP), characterizing electron transport in graphene/Cu sample and reduced graphene oxide material, which determines the sampling depth of XPS and AES were evaluated from relative Elastic Peak Electron Spectroscopy (EPES) measurements with the Au standard in the energy range 0.5-2 keV. The measured IMFPs were compared with IMFPs resulting from experimental optical data published in the literature for the graphite sample. The EPES IMFP values at 0.5 and 1.5 keV was practically identical to that calculated from optical data for graphite (less than 4% deviation). For energies 1 and 2 keV, the EPES IMFPs for rGO were deviated up to 14% from IMFPs calculated using the optical data by Tanuma et al. [1]. Before EPES measurements all samples were characterized by various techniques like: FE-SEM, AFM, XPS, AES and REELS to visualize the surface morphology/topography and identify the chemical composition.

  6. Clinical application of removable partial dentures using thermoplastic resin-part I: definition and indication of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-Ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-01-01

    This position paper proposes a definition and naming standard for removable partial dentures (RPDs) using thermoplastic resin, and presents a guideline for clinical application. A panel of 14 experts having broad experience with clinical application of RPDs using thermoplastic resin was selected from members of the Japan Prosthodontic Society. At a meeting of the panel, "non-metal clasp denture" was referred as the generic name of RPDs with retentive elements (resin clasps) made of thermoplastic resin. The panel classified non-metal clasp dentures into two types: one with a flexible structure that lacks a metal framework and the other having a rigid structure that includes a metal framework. According to current prosthetic principles, flexible non-metal clasp dentures are not recommended as definitive dentures, except for limited cases such as patients with a metal allergy. Rigid non-metal clasp dentures are recommended in cases where patients will not accept metal clasps for esthetic reasons. Non-metal clasp dentures should follow the same design principles as conventional RPDs using metal clasps. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. Surface properties of copper based cermet materials

    International Nuclear Information System (INIS)

    Voinea, M.; Vladuta, C.; Bogatu, C.; Duta, A.

    2008-01-01

    The paper presents the characterization of the surface properties of copper based cermets obtained by two different techniques: spray pyrolysis deposition (SPD) and electrodeposition. Copper acetate was used as precursor of Cu/CuO x cermet. The surface morphology was tailored by adding copolymers of maleic anhydride with controlled hydrophobia. The films morphology of Cu/CuO x was assessed using contact angle measurements and AFM analysis. The porous structures obtained via SPD lead to higher liquid adsorption rate than the electrodeposited films. A highly polar liquid - water is recommended as testing liquid in contact angle measurements, for estimating the porosity of copper based cermets, while glycerol can be used to distinguish among ionic and metal predominant structures. Thus, contact angle measurements can be used for a primary evaluation of the films morphology and, on the other hand, of the ratio between the cermet components

  8. Conventional Complete Denture in Patients with Ectodermal Dysplasia

    Directory of Open Access Journals (Sweden)

    Larissa Soares Reis Vilanova

    2015-01-01

    Full Text Available Ectodermal dysplasia is described as heritable conditions that involve anomalies of structures derived from the ectoderm, including hypodontia. In the cases of edentulous young patients, who did not finish their craniofacial growth, treatment with conventional complete denture is a suitable alternative. The aim of this study was to report a case of mandibular edentulism treated with conventional complete denture in a thirteen-year-old patient diagnosed with hidrotic ectodermal dysplasia. Typical features, such as frontal bossing, depressed nasal bridge, protuberant lips, scarce hair, and brittle nails, were visualized during the extraoral examination. The intraoral inspection and radiographic analysis revealed oligodontia, dental malformation, and prolonged retention of deciduous teeth at maxilla and total edentulism at mandible. A conventional complete denture was planned and constructed following the same steps of technique as recommended in adults. Although this option is not a definitive treatment, the patient and his parents were satisfied with his improvement in chewing and speech, as well as with the aesthetic benefits.

  9. Emerging Ceramic-based Materials for Dentistry

    Science.gov (United States)

    Denry, I.; Kelly, J.R.

    2014-01-01

    Our goal is to give an overview of a selection of emerging ceramics and issues for dental or biomedical applications, with emphasis on specific challenges associated with full-contour zirconia ceramics, and a brief synopsis on new machinable glass-ceramics and ceramic-based interpenetrating phase composites. Selected fabrication techniques relevant to dental or biomedical applications such as microwave sintering, spark plasma sintering, and additive manufacturing are also reviewed. Where appropriate, the authors have added their opinions and guidance. PMID:25274751

  10. A Technique to Facilitate Tooth Modification for Removable Partial Denture Prosthesis Guide Planes.

    Science.gov (United States)

    Haeberle, C Brent; Abreu, Amara; Metzler, Kurt

    2016-07-01

    The technique in this article was developed to provide a means to create prepared guide planes of proper dimension to ensure a more stable and retentive removable partial denture prosthesis (RPDP) framework when providing this service for a patient. Using commonly found clinical materials, a paralleling device can be fabricated from the modified diagnostic cast of the patient's dental arch requiring an RPDP. Polymethyl methacrylate or composite added to an altered thermoplastic form can be positioned intraorally and used as a guide to predictably adjust tooth structure for guide planes. Since it can potentially minimize the number of impressions and diagnostic casts made during the procedure, this can help achieve the desired result more efficiently and quickly for the patient. © 2015 by the American College of Prosthodontists.

  11. Emerging ceramic-based materials for dentistry.

    Science.gov (United States)

    Denry, I; Kelly, J R

    2014-12-01

    Our goal is to give an overview of a selection of emerging ceramics and issues for dental or biomedical applications, with emphasis on specific challenges associated with full-contour zirconia ceramics, and a brief synopsis on new machinable glass-ceramics and ceramic-based interpenetrating phase composites. Selected fabrication techniques relevant to dental or biomedical applications such as microwave sintering, spark plasma sintering, and additive manufacturing are also reviewed. Where appropriate, the authors have added their opinions and guidance. © International & American Associations for Dental Research.

  12. Different types of antagonists modify the outcome of complete denture renewal.

    Science.gov (United States)

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  13. ARTIFICIAL NEURAL NETWORKS BASED GEARS MATERIAL SELECTION HYBRID INTELLIGENT SYSTEM

    Institute of Scientific and Technical Information of China (English)

    X.C. Li; W.X. Zhu; G. Chen; D.S. Mei; J. Zhang; K.M. Chen

    2003-01-01

    An artificial neural networks(ANNs) based gear material selection hybrid intelligent system is established by analyzing the individual advantages and weakness of expert system (ES) and ANNs and the applications in material select of them. The system mainly consists of tow parts: ES and ANNs. By being trained with much data samples,the back propagation (BP) ANN gets the knowledge of gear materials selection, and is able to inference according to user input. The system realizes the complementing of ANNs and ES. Using this system, engineers without materials selection experience can conveniently deal with gear materials selection.

  14. A data base for aging of structural materials

    International Nuclear Information System (INIS)

    Oland, C.B.; Naus, D.J.; Jerath, S.

    1993-01-01

    The U.S. Nuclear Regulatory Commission (USNRC) initiated a Structural Aging (SAG) Program at the Oak Ridge National Laboratory (ORNL). The objective of the program is to provide assistance in identifying potential structural safety issues and to establish acceptance criteria for use in nuclear power plant evaluations for continued service. One of the main parts of the program focuses on the development of a Structural Materials Information Center where long-term and environment-dependent material properties are being collected and assembled into a data base. This data base is presented in two complementary formats. The Structural Materials Handbook is an expandable, hard-copy reference document that contains the complete data base for each material. The Structural Materials Electronic Data Base is accessible using an IBM-compatible personal computer. This paper presents an overview of the Structural Materials Information Center and briefly describes the features of the handbook and the electronic data base. In addition, a proposed method for using the data base to establish current property values for materials in existing concrete structures and to estimate the future performance of these materials is also presented. (author)

  15. A data base for aging of structural materials

    International Nuclear Information System (INIS)

    Oland, C.B.; Naus, D.J.; Jerath, S.

    1993-01-01

    USNRC initiated a Structural Aging (SAG) Program ORNL. The objective of the program is to provide assistance in identifying potential structural safety issues and to establish acceptance criteria for use in nuclear power plant evaluations for continued service. One main part focuses on the development of a Structural Materials Information Center where long-term and environment-dependent material properties are being collected and assembled into a data base. This data base is presented in two complementary formats. The Structural Materials Handbook is an expandable, hard-copy reference document that contains the complete data base for each material. The Structural Materials Electronic Data Base is accessible using an IBM-compatible personal computer. This paper presents an overview of the Structural Materials Information Center and briefly describes the features of the handbook and the electronic data base. In addition, a proposed method for using the data base to establish current property values for materials in existing concrete structures and to estimate the future performance of these materials is also presented

  16. Wearable energy sources based on 2D materials.

    Science.gov (United States)

    Yi, Fang; Ren, Huaying; Shan, Jingyuan; Sun, Xiao; Wei, Di; Liu, Zhongfan

    2018-05-08

    Wearable energy sources are in urgent demand due to the rapid development of wearable electronics. Besides flexibility and ultrathin thickness, emerging 2D materials present certain extraordinary properties that surpass the properties of conventional materials, which make them advantageous for high-performance wearable energy sources. Here, we provide a comprehensive review of recent advances in 2D material based wearable energy sources including wearable batteries, supercapacitors, and different types of energy harvesters. The crucial roles of 2D materials in the wearable energy sources are highlighted. Based on the current progress, the existing challenges and future prospects are outlined and discussed.

  17. Effects of different production technologies on mechanical and metallurgical properties of precious metal denture alloys

    Science.gov (United States)

    Ferro, Paolo; Battaglia, Eleonora; Capuzzi, Stefano; Berto, Filippo

    2017-12-01

    Precious metal alloys can be supplied in traditional plate form or innovative drop form with high degree of purity. The aim of the present work is to evaluate the influence of precious metal alloy form on metallurgical and mechanical properties of the final dental products with particular reference to metal-ceramic bond strength and casting defects. A widely used alloy for denture was selected; its nominal composition was close to 55 wt% Pd - 34 wt% Ag - 6 wt% In - 3 wt% Sn. Specimens were produced starting from the alloy in both plate and drop forms. A specific test method was developed to obtain results that could be representative of the real conditions of use. In order to achieve further information about the adhesion behaviour and resistance, the fracture surfaces of the samples were observed using `Scanning Electron Microscopy (SEM)'. Moreover, material defects caused by the moulding process were studied. The form of the alloy before casting does not significantly influence the shear bond strength between the metal and the ceramic material (p-value=0,976); however, according to SEM images, products from drop form alloy show less solidification defects compared to products obtained with plate form alloy. This was attributed to the absence of polluting additives used in the production of drop form alloy. This study shows that the use of precious metal denture alloys supplied in drop form does not affect the metal-ceramic bond strength compared to alloys supplied in the traditional plate form. However, compared to the plate form, the drop form is found free of solidification defects, less expensive to produce and characterized by minor environmental impacts.

  18. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of removable partial denture

    Directory of Open Access Journals (Sweden)

    Šćepanović Miodrag

    2013-01-01

    Full Text Available Bacground/Aim. Retentive force of removable partial denture (RPD directly depends on elastic force of stretched retentive clasp arms (RCAs. During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profiles and defining the optimal shapes of RCAs for stress distribution and safety factor aspects. Methods. Computer-aided-design (CAD models of RCAs with simulated properties of materials used for fabrication of RPD cobalt-chromium-molybdenum (CoCrMo alloy, commercially pure titanium (CPTi and polyacetale were analyzed. Results. The research showed that geometrics of Rapidflex profiles from the BIOS concept are defined for designing and modeling RCAs from CoCrMo alloys. I-Bar and Bonihard clasps made from CPTi might have the same design as Co- CrMo clasp only by safety factor aspect, but it is obvious that CPTi are much more flexible, so their shape must be more massive. Polyacetale clasps should not be fabricated by BIOS concept for CoCrMo alloy. A proof for that is the low value of safety factor. Conclusion. The BIOS concept should be used only for RCAs made of CoCrMo alloy and different wax profiles should be used for fabricating clasps of other investigated materials. The contribution of this study may be the improvement of present systems for defining the clasps shapes made from CoCrMo alloys. The more significant application is possibility of creating new concepts in defining shapes of RCA made from CPTi and polyacetale.

  19. Topological Material-Based Spin Devices

    Science.gov (United States)

    Zhang, Minhao; Wang, Xuefeng

    Three-dimensional topological insulators have insulating bulk and gapless helical surface states. One of the most fascinating properties of the metallic surface states is the spin-momentum helical locking. The giant current-driven torques on the magnetic layer have been discovered in TI/ferromagnet bilayers originating from the spin-momentum helical locking, enabling the efficient magnetization switching with a low current density. We demonstrated the current-direction dependent on-off state in TIs-based spin valve devices for memory and logic applications. Further, we demonstrated the Bi2Se3 system will go from a topologically nontrivial state to a topologically trivial state when Bi atoms are replaced by lighter In atoms. Here, topologically trivial metal (BixIny)2 Se3 with high mobility also facilitates the realization of its application in multifunctional spintronic devices.

  20. Environmental assessment of biomass based materials

    DEFF Research Database (Denmark)

    Jørgensen, Susanne Vedel

    of these impacts in LCA, in order to get a realistic picture of the overall impacts from a biomass feedstock crop establishment, and thus downstream products. However, there is a challenge in terms of e.g. the preliminary state of methods, and the requirements to availability of local data. Available biomass...... level. The temporal scope is defined by the impact category considered. The technological scope includes both current environmental performance of biomaterials and a discussion of future perspectives, including potentials for future change in their environmental impacts compared to fossil based...... place in biomaterials, on which there is currently no consensus. Other important environmental aspects related to biomaterials that are currently not generally included in LCAs are land use and land use change (LULUC) related impacts, such as changes in biogenic carbon stocks (especially including soil...

  1. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    Science.gov (United States)

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  2. Daya Hambat Infusum Daun Sirih Terhadap Pertumbuhan Staphylococcus aureus Yang Diisolasi Dari Denture Stomatitis ; Penelitian In Vitro.

    OpenAIRE

    bin Abdullah, Muhammad Naim

    2011-01-01

    Denture Stomatitis merupakan lesi mukosa oral berwarna merah, sakit, dan bengkak, kondisi ini karena kebiasaan jelek pada pemakai gigitiruan yang tidak mumbuka protesa pada malam hari dan jarang dibersihkan. Faktor sistemik yang mendukung terjadinya Denture Stomatitis dapat disebabkan oleh beberapa bakteri, salah satunya Staphylococcus aureus. Pencegahan Denture Stomatitis dapat dilakukan dengan sering membersihkan gigitiruan dan pemakaian obat kumur. Tujuan penelitian ini adalah untuk menguj...

  3. Biofuels 2020: Biorefineries based on lignocellulosic materials.

    Science.gov (United States)

    Valdivia, Miguel; Galan, Jose Luis; Laffarga, Joaquina; Ramos, Juan-Luis

    2016-09-01

    The production of liquid biofuels to blend with gasoline is of worldwide importance to secure the energy supply while reducing the use of fossil fuels, supporting the development of rural technology with knowledge-based jobs and mitigating greenhouse gas emissions. Today, engineering for plant construction is accessible and new processes using agricultural residues and municipal solid wastes have reached a good degree of maturity and high conversion yields (almost 90% of polysaccharides are converted into monosaccharides ready for fermentation). For the complete success of the 2G technology, it is still necessary to overcome a number of limitations that prevent a first-of-a-kind plant from operating at nominal capacity. We also claim that the triumph of 2G technology requires the development of favourable logistics to guarantee biomass supply and make all actors (farmers, investors, industrial entrepreneurs, government, others) aware that success relies on agreement advances. The growth of ethanol production for 2020 seems to be secured with a number of 2G plants, but public/private investments are still necessary to enable 2G technology to move on ahead from its very early stages to a more mature consolidated technology. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  4. Propagation law of impact elastic wave based on specific materials

    Directory of Open Access Journals (Sweden)

    Chunmin CHEN

    2017-02-01

    Full Text Available In order to explore the propagation law of the impact elastic wave on the platform, the experimental platform is built by using the specific isotropic materials and anisotropic materials. The glass cloth epoxy laminated plate is used for anisotropic material, and an organic glass plate is used for isotropic material. The PVDF sensors adhered on the specific materials are utilized to collect data, and the elastic wave propagation law of different thick plates and laminated plates under impact conditions is analyzed. The Experimental results show that in anisotropic material, transverse wave propagation speed along the fiber arrangement direction is the fastest, while longitudinal wave propagation speed is the slowest. The longitudinal wave propagation speed in anisotropic laminates is much slower than that in the laminated thick plates. In the test channel arranged along a particular angle away from the central region of the material, transverse wave propagation speed is larger. Based on the experimental results, this paper proposes a material combination mode which is advantageous to elastic wave propagation and diffusion in shock-isolating materials. It is proposed to design a composite material with high acoustic velocity by adding regularly arranged fibrous materials. The overall design of the barrier material is a layered structure and a certain number of 90°zigzag structure.

  5. Silicon based light-emitting materials and devices

    International Nuclear Information System (INIS)

    Chen Weide

    1999-01-01

    Silicon based light-emitting materials and devices are the key to optoelectronic integration. Recently, there has been significant progress in materials engineering methods. The author reviews the latest developments in this area including erbium doped silicon, porous silicon, nanocrystalline silicon and Si/SiO 2 superlattice structures. The incorporation of these different materials into devices is described and future device prospects are assessed

  6. Biogas Filter Based on Local Natural Zeolite Materials

    OpenAIRE

    Krido Wahono, Satriyo; Anggo Rizal, Wahyu

    2014-01-01

    UPT BPPTK LIPI has created a biogas filter tool to improve the purity of methane in the biogas. The device shaped cylindrical tube containing absorbent materials which based on local natural zeolite of Indonesia. The absorbent has been activated and modified with other materials. This absorbtion material has multi-adsorption capacity for almost impurities gas of biogas. The biogas  filter increase methane content of biogas for 5-20%. The biogas filter improve the biogas’s performance such as ...

  7. Graphene-Based Carbon Materials for Electrochemical Energy Storage

    Directory of Open Access Journals (Sweden)

    Fei Liu

    2013-01-01

    Full Text Available Because of their unique 2D structure and numerous fascinating properties, graphene-based materials have attracted particular attention for their potential applications in energy storage devices. In this review paper, we focus on the latest work regarding the development of electrode materials for batteries and supercapacitors from graphene and graphene-based carbon materials. To begin, the advantages of graphene as an electrode material and the existing problems facing its use in this application will be discussed. The next several sections deal with three different methods for improving the energy storage performance of graphene: the restacking of the nanosheets, the doping of graphene with other elements, and the creation of defects on graphene planes. State-of-the-art work is reviewed. Finally, the prospects and further developments in the field of graphene-based materials for electrochemical energy storage are discussed.

  8. Vinegar as an antimicrobial agent for control of Candida spp. in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Telma Maria Silva Pinto

    2008-12-01

    Full Text Available The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3 overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation. The results were analyzed using Spearman's correlation and Student's t-test (p£0.05. Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients.

  9. Correlation between factors associated with the removable partial dentures use and Candida spp. in saliva.

    Science.gov (United States)

    Gusmão, João Milton Rocha; Ferreira dos Santos, Silvana Soleo; Neisser, Maximiliano Piero; Jorge, Antônio Olavo Cardoso; Faria, Ms Ivan

    2011-12-01

    To correlate the presence and number of Candida spp. in the saliva of wearers of removable partial dentures retained with precision attachments with the proportion of metal/acrylic resin present in the dentures. Saliva samples from 40 removable partial denture wearers (test) and one paired sample of individuals, non-wearers of any type of removable denture (control) were collected, seeded, and the colony forming units of Candida counted and identified. The metal/acrylic resin proportion of each denture was quantified, using silicone plates pressed over each denture. Candida spp. was found in the saliva of 80% of the individuals in the test group and 65% of the control, with C. albicans being the most prevalent species. The test group presented with the highest number of colony forming units of Candida per ml of saliva, and there was weak correlation between this number and the metal and resin area of the denture (Pearson's coefficient of correlation). Greater prevalence and a higher number of colony forming units of Candida per ml of saliva occurred in removable partial denture wearers (p = 0.04) with a weak positive correlation between the metal and resin area and the number of colony forming units of Candida per ml of saliva. However, this correlation was more significant for the area of resin. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  10. 21 CFR 872.3450 - Ethylene oxide homopolymer and/or karaya denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or karaya denture... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3450 Ethylene oxide homopolymer and/or karaya denture adhesive. (a) Identification. Ethylene oxide homopolymer and/or karaya...

  11. 21 CFR 872.3410 - Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or....3410 Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive. (a) Identification. An ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive is a device...

  12. Supramolecular materials based on hydrogen-bonded polymers

    NARCIS (Netherlands)

    ten Brinke, Gerrit; Ruokolainen, Janne; Ikkala, Olli; Binder, W

    2007-01-01

    Combining supramolecular principles with block copolymer self-assembly offers unique possibilities to create materials with responsive and/or tunable properties. The present chapter focuses on supramolecular materials based on hydrogen bonding and (block co-) polymers. Several cases will be

  13. Antibacterial properties of nanocomposite materials and compositions on there bases

    International Nuclear Information System (INIS)

    Podol'skaya, V.I.; Vojtenko, O.Yu.; Grishenko, N.I.; Ul'berg, Z.P.; Yakubenko, L.N.

    2012-01-01

    The structured nanobiocomposite materials based on microbial cells and colloidal silver can serve as the new adjuvant systems. These composite materials being filled with active components, in particular the medications allow to prepare the long release preparatio