WorldWideScience

Sample records for dental devices prosthetic

  1. An Evaluation of Dental Prosthetic Status and Prosthetic Needs ...

    African Journals Online (AJOL)

    present cross‑sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs .... who consented to become part of the study guided us to the .... to the reason that our study population comprised of adults with low SES. ... Arora M, Schwarz E, Sivaneswaran S, Banks E. Cigarette smoking.

  2. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  3. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  4. Carbon based prosthetic devices

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, D.J.; Carroll, D.W.; Barbero, R.S.; Archuleta, T. [Los Alamos National Lab., NM (US); Klawitter, J.J.; Ogilvie, W.; Strzepa, P. [Ascension Orthopedics (US); Cook, S.D. [Tulane Univ., New Orleans, LA (US). School of Medicine

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project objective was to evaluate the use of carbon/carbon-fiber-reinforced composites for use in endoprosthetic devices. The application of these materials for the metacarpophalangeal (MP) joints of the hand was investigated. Issues concerning mechanical properties, bone fixation, biocompatibility, and wear are discussed. A system consisting of fiber reinforced materials with a pyrolytic carbon matrix and diamond-like, carbon-coated wear surfaces was developed. Processes were developed for the chemical vapor infiltration (CVI) of pyrolytic carbon into porous fiber preforms with the ability to tailor the outer porosity of the device to provide a surface for bone in-growth. A method for coating diamond-like carbon (DLC) on the articulating surface by plasma-assisted chemical vapor deposition (CVD) was developed. Preliminary results on mechanical properties of the composite system are discussed and initial biocompatibility studies were performed.

  5. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  6. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  7. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Prosthetic Status and Prosthetic Need Among the Patients Attending Various Dental Institutes of Ahmedabad and Gandhinagar District, Gujarat

    OpenAIRE

    Shah, Vrinda R.; Shah, Darshana N.; Parmar, Chaitanya H.

    2012-01-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment ...

  9. Treatment of radiation dental caries with fixed dental prosthetic constructions

    Energy Technology Data Exchange (ETDEWEB)

    Dachev, B [Vissh Meditsinski Inst., Sofia (Bulgaria)

    1974-01-01

    On the basis of clinical observations for many years the author established that the covering of the teeth, progressively developing radiation caries, with crowns of precious metal and plastics is a safe way for their protection. The crown isolates the teeth from the saliva with its changed composition, quantity and changed pH. A prophylactic effect is obtained with the covering of the morbid teeth with radiation caries, concerning the possibilities of osteoradionecrosis development, due to the restriction of the ways of secondary infection penetration. The carried out treatment with fixed crowns preserves the anatomical teeth shape, radiation caries stops its development and the masticatory function of the dentition is recovered. After radiation treatment in the maxillofacial region with hard dental tissues affection which cannot be restored by way of ordinary definite fillings--indications for crown covering exist. The carried out observations reveal that complex cares are necessary in the radiation caries treatment on the part of specialists in therapeutic and orthopedic stomatology with consultations with radiologists. (auth)

  10. Prosthetic status and prosthetic need among the patients attending various dental institutes of ahmedabad and gandhinagar district, gujarat.

    Science.gov (United States)

    Shah, Vrinda R; Shah, Darshana N; Parmar, Chaitanya H

    2012-09-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment form (1997). Prosthetic status and prosthetic treatment need was recorded. Out of 510, any type of Edentulousness was 322 (63 %). Among them, 254 (49.8 %) were partially edentulous while 68 (13.3 %) were completely edentulous. Only 69 (13 %) were having any prosthesis in upper arch while only 80 (16 %) were having any prosthesis in lower arch. Need for any type of prosthesis in upper and lower arch was 55 and 60 % in males and females, respectively. In lower social class group need of prosthesis in upper and lower arch was 62 and 63 %, respectively. It was found that prosthetic status and prosthetic treatment need increased with increase in age. Steps should be taken to overcome this disparity and more emphasis should be given to meet the felt need of the people through government and non government organizations to improve the oral health. The unmet prosthetic treatment need should be met to rehabilitate needy people so that their disability may be limited.

  11. Potentiometric stripping analysis of lead and cadmium leaching from dental prosthetic materials and teeth

    Directory of Open Access Journals (Sweden)

    GORAN M. NIKOLIC

    2004-07-01

    Full Text Available Potentiometric stipping analysis (PSA was applied for the determination of lead and cadmium leaching from dental prosthetic materials and teeth. The soluble lead content in finished dental implants was found to be much lower than that of the individual components used for their preparation. Cadmium was not detected in dental implants and materials under the defined conditions. The soluble lead and cadmium content of teeth was slightly lower than the lead and cadmium content in whole teeth (w/w reported by other researchers, except in the case of a tooth with removed amalgam filling. The results of this work suggest that PSA may be a good method for lead and cadmium leaching studies for investigation of the biocompatibility of dental prosthetic materials.

  12. Prosthetic vision: devices, patient outcomes and retinal research.

    Science.gov (United States)

    Hadjinicolaou, Alex E; Meffin, Hamish; Maturana, Matias I; Cloherty, Shaun L; Ibbotson, Michael R

    2015-09-01

    Retinal disease and its associated retinal degeneration can lead to the loss of photoreceptors and therefore, profound blindness. While retinal degeneration destroys the photoreceptors, the neural circuits that convey information from the eye to the brain are sufficiently preserved to make it possible to restore sight using prosthetic devices. Typically, these devices consist of a digital camera and an implantable neurostimulator. The image sensor in a digital camera has the same spatiotopic arrangement as the photoreceptors of the retina. Therefore, it is possible to extract meaningful spatial information from an image and deliver it via an array of stimulating electrodes directly to the surviving retinal circuits. Here, we review the structure and function of normal and degenerate retina. The different approaches to prosthetic implant design are described in the context of human and preclinical trials. In the last section, we review studies of electrical properties of the retina and its response to electrical stimulation. These types of investigation are currently assessing a number of key challenges identified in human trials, including stimulation efficacy, spatial localisation, desensitisation to repetitive stimulation and selective activation of retinal cell populations. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  13. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  14. 75 FR 33169 - Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation...

    Science.gov (United States)

    2010-06-11

    .... FDA-2008-N-0163] (formerly Docket No. 2001N-0067) RIN 0910-AG21 Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation of Special Controls for Dental Amalgam... the Federal Register of August 4, 2009 (74 FR 38686) which classified dental amalgam as a class II...

  15. Prosthetic joint infection, dental treatment and antibiotic prophylaxis

    Directory of Open Access Journals (Sweden)

    Marthinus J. Kotzé

    2009-06-01

    Full Text Available Current international and national prophylactic antibiotic regimens have been analyzed in respect of the prevention of bacteremia after dental and surgical procedures and, therefore, of joint prosthesis infection. This information was used to formulate guidelines for the Department of Maxillofacial and Oral Surgery. Publications since 2003 were used in this research. In addition, recommendations of accredited institutions and associations were examined. These included the guidelines of the American Dental Association in association with the American Academy of Orthopaedic Surgeons (2003, the American Heart Association (2007, the Working Party of the British Society for Antimicrobial Chemotherapy (2006 and the Australian Dental Guidelines (2005. No guidelines published by any institution in South Africa were found. The general rationale for the use of antibiotic prophylaxis for surgical (including dental interventions is that those procedures may result in a bacteremia that may cause infection in joint prostheses. Antibiotics, however, should therefore be administered to susceptible patients, e.g. immunocompromised patients, prior to the development of bacteremia. The guidelines recommended for use in South Africa are based solely on those used outside South Africa. South Africa is regarded as a developing country with its own population and demographic characteristics. Eleven percent of our population is infected with HIV, and a specific guideline for prophylactic antibiotic treatment is, therefore, essential.

  16. 38 CFR 17.122 - Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices...

    Science.gov (United States)

    2010-07-01

    ... of the expenses of repairs to prosthetic appliances and similar devices furnished without prior... Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices furnished without prior authorization. The expenses of repairs to prosthetic appliances, or similar appliances...

  17. 21 CFR 872.3240 - Dental bur.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental bur. 872.3240 Section 872.3240 Food and... DENTAL DEVICES Prosthetic Devices § 872.3240 Dental bur. (a) Identification. A dental bur is a rotary... materials intended for use in the fabrication of dental devices. (b) Classification. Class I (general...

  18. An evaluation of patient's decisions regarding dental prosthetic treatment

    Directory of Open Access Journals (Sweden)

    Nupur D Shrirao

    2016-01-01

    Full Text Available Introduction: For fabricating dental prostheses that meet patients' demands and have good longevity and function, appropriate treatment planning and decision-making are required. Therefore, not only technical skills and clinical judgment of the dentist are needed, but also patients' attitude toward treatment plays a critical role in posttreatment satisfaction. Aim: The aim of this study is to investigate the factors affecting decision-making and the selection of dental prosthesis by the patients. Materials and Methods: A cross-sectional survey to determine patients' attitudes about replacement of teeth was conducted. This survey was performed with the help of a prevalidated questionnaire, which contained the demographic data of every patient, whether or not they accept the treatment plan proposed by the dentist, and a close-ended multiple choice question stating the reasons cited by them if they decline the proposed treatment plan. Results: The data were subjected to statistical analysis by Chi-square test at a significance level of P< 0.05. A relationship between the demographical information such as age, gender, educational status, marital status, and monthly income of each patient and the single best reason opted by them to not undergo the proposed treatment plan was established. Conclusions: In the sample of population studied, most of the patients declined the proposed treatment plan and accepted the alternate one. High expenditure is the most common reason for this rejection.

  19. Clinical decision - making review on magnetic attachments versus mechanical attachments in dental prosthetics

    Directory of Open Access Journals (Sweden)

    Francesca Fabiano

    2017-11-01

    Full Text Available Background Conventional dentures in edentulous patients show some limitations due to the lack of retention, support and stability thus resulting in difficulty to chew. The modern implantology allows to use different implant overdentures and different attachment systems. The selection of the attachment by practitioners is mainly influenced by the clinical experience or technical preferences. Aims The aim of the present review is to provide an adequate background to the clinicians, in order to select the prosthetic attachments according to the current literature. The mechanical attachments have been compared to the magnetic devices, with the aim to guide the decision of the practitioners. Methods Articles topics selection was based on the use of magnetic attachments in dentistry and the comparison between them and mechanical connectors. The databases used were PubMed/MEDLINE, Google Scholar and ISI Web of Science. A critical evaluation of the selected paper has been made to choose the ones that matched the inclusion criteria. Results Nowadays, few studies have compared different attachments in a manner useful for clinical decision-making. The main problem limiting long-term durability of magnetic attachments in the oral fluid is the poor corrosion resistance of permanent magnets and the consequent leaching of cytotoxic ions. Conclusion Magnetic attachments in comparison with other attaching systems can be useful in patients with special needs, in patients with limited interocclusal space, or in patients with neuromuscular limitations, thanks to the automatic reseating properties. However, it’s important to highlight that the mechanical attachments still represent the best choice in common conditions requiring dental prostheses.

  20. Accuracy of mechanical torque-limiting devices for dental implants.

    Science.gov (United States)

    L'Homme-Langlois, Emilie; Yilmaz, Burak; Chien, Hua-Hong; McGlumphy, Edwin

    2015-10-01

    A common complication in implant dentistry is unintentional implant screw loosening. The critical factor in the prevention of screw loosening is the delivery of the appropriate target torque value. Mechanical torque-limiting devices (MTLDs) are the most frequently recommended devices by the implant manufacturers to deliver the target torque value to the screw. Two types of MTLDs are available: friction-style and spring-style. Limited information is available regarding the influence of device type on the accuracy of MTLDs. The purpose of this study was to determine and compare the accuracy of spring-style and friction-style MTLDs. Five MTLDs from 6 different dental implant manufacturers (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI], and Nobel Biocare) (n=5 per manufacturer) were selected to determine their accuracy in delivering target torque values preset by their manufacturers. All torque-limiting devices were new and there were 3 manufacturers for the friction-style and 3 manufacturers for the spring-style. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (Chatillon Model DFS2-R-ND; Ametek) was used to record the measurements. Statistical analysis used nonparametric tests to determine the accuracy of the MTLDs in delivering target torque values and Bonferroni post hoc tests were used to assess pairwise comparisons. Median absolute difference between delivered torque values and target torque values of friction-style and spring-style MTLDs were not significantly different (P>.05). Accuracy of Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly different than Biohorizons torque-limiting devices (Ptorque value. Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly more accurate than Biohorizons (C) torque-limiting devices (Ptorque-limiting devices fell within ±10% of the target torque value preset by the

  1. 21 CFR 872.3700 - Dental mercury.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental mercury. 872.3700 Section 872.3700 Food and... DENTAL DEVICES Prosthetic Devices § 872.3700 Dental mercury. (a) Identification. Dental mercury is a... dental cavity or a broken tooth. (b) Classification. Class I. ...

  2. 21 CFR 872.3275 - Dental cement.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental cement. 872.3275 Section 872.3275 Food and... DENTAL DEVICES Prosthetic Devices § 872.3275 Dental cement. (a) Zinc oxide-eugenol—(1) Identification... filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or...

  3. Anatomical sciences: A foundation for a solid learning experience in dental technology and dental prosthetics.

    Science.gov (United States)

    Bakr, Mahmoud M; Thompson, C Mark; Massadiq, Magdalena

    2017-07-01

    Basic science courses are extremely important as a foundation for scaffolding knowledge and then applying it in future courses, clinical situations as well as in a professional career. Anatomical sciences, which include tooth morphology, oral histology, oral embryology, and head and neck anatomy form a core part of the preclinical courses in dental technology programs. In this article, the importance and relevance of anatomical sciences to dental personnel with no direct contact with patients (dental technicians) and limited discipline related contact with patients (dental prosthetists) is highlighted. Some light is shed on the role of anatomical sciences in the pedagogical framework and its significance in the educational process and interprofessional learning of dental technicians and prosthetists using oral biology as an example in the dental curriculum. To conclude, anatomical sciences allow dental technicians and prosthetists to a gain a better insight of how tissues function, leading to a better understanding of diagnosis, comprehensive treatment planning and referrals if needed. Patient communication and satisfaction also increases as a result of this deep understanding of oral tissues. Anatomical sciences bridge the gap between basic science, preclinical, and clinical courses, which leads to a holistic approach in patient management. Finally, treatment outcomes are positively affected due to the appreciation of the macro and micro structure of oral tissues. Anat Sci Educ 10: 395-404. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  4. 21 CFR 872.3640 - Endosseous dental implant.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  5. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  6. Using computed tomography and 3D printing to construct custom prosthetics attachments and devices.

    Science.gov (United States)

    Liacouras, Peter C; Sahajwalla, Divya; Beachler, Mark D; Sleeman, Todd; Ho, Vincent B; Lichtenberger, John P

    2017-01-01

    The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities. Prosthetists and engineers perform research and implement digitally designs in collaboration to generate equipment for their patient's rehabilitation needs. 3D printing allows for these devices to be manufactured from an array of materials ranging from plastic to titanium alloy. Many designs require form fitting to a prosthetic socket or a complex surface geometry. Specialty items can be scanned using computed tomography and digitally reconstructed to produce a virtual 3D model the engineer can use to design the necessary features of the desired prosthetic, device, or attachment. Completed devices are tested for fit and function. Numerous custom prostheses and attachments have been successfully translated from the research domain to clinical reality, in particular, those that feature the use of computed tomography (CT) reconstructions. The purpose of this project is to describe the research pathways to implementation for the following clinical designs: sets of bilateral hockey skates; custom weightlifting prosthetic hands; and a wine glass holder. This article will demonstrate how to incorporate CT imaging and 3D printing in the design and manufacturing process of custom attachments and assistive technology devices. Even though some of these prosthesis attachments may be relatively simple in design to an engineer, they have an enormous impact on the lives of our wounded warriors.

  7. Dental impression technique using optoelectronic devices

    Science.gov (United States)

    Sinescu, Cosmin; Barua, Souman; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Duma, Virgil-Florin; Gabor, Alin Gabriel; Zaharia, Cristian; Bradu, Adrian; Podoleanu, Adrian G.

    2018-03-01

    INTRODUCTION: The use of Optical Coherence Tomography (OCT) as a non-invasive and high precision quantitative information providing tool has been well established by researches within the last decade. The marginal discrepancy values can be scrutinized in optical biopsy made in three dimensional (3D) micro millimetre scale and reveal detailed qualitative and quantitative information of soft and hard tissues. OCT-based high resolution 3D images can provide a significant impact on finding recurrent caries, restorative failure, analysing the precision of crown preparation, and prosthetic elements marginal adaptation error with the gingiva and dental hard tissues. During the CAD/CAM process of prosthodontic restorations, the circumvent of any error is important for the practitioner and the technician to reduce waste of time and material. Additionally, OCT images help to achieve a new or semi-skilled practitioner to analyse their crown preparation works and help to develop their skills faster than in a conventional way. The aim of this study is to highlight the advantages of OCT in high precision prosthodontic restorations. MATERIALS AND METHODS: 25 preparations of frontal and lateral teeth were performed for 7 different patients. The impressions of the prosthetic fields were obtained both using a conventional optoelectronic system (Apolo Di, Syrona) and a Spectral Domain using OCT (Dental prototype, working at 860 nm). For the conventional impression technique the preparation margins were been prelevated by gingival impregnated cords. No specific treatments were performed by the OCT impression technique. RESULTS: The scanning performed by conventional optoelectronic system proved to be quick and accurate in terms of impression technology. The results were represented by 3D virtual models obtained after the scanning procedure was completed. In order to obtain a good optical impression a gingival retraction cord was inserted between the prepared tooth and the gingival

  8. Simulating The Technological Movements Of The Equipment Used For Manufacturing Prosthetic Devices Using 3D Models

    Science.gov (United States)

    Chicea, Anca-Lucia

    2015-09-01

    The paper presents the process of building geometric and kinematic models of a technological equipment used in the process of manufacturing devices. First, the process of building the model for a six axes industrial robot is presented. In the second part of the paper, the process of building the model for a five-axis CNC milling machining center is also shown. Both models can be used for accurate cutting processes simulation of complex parts, such as prosthetic devices.

  9. Corynebacterium minutissimum vascular graft infection: case report and review of 281 cases of prosthetic device-related Corynebacterium infection.

    Science.gov (United States)

    Reece, Rebecca M; Cunha, Cheston B; Rich, Josiah D

    2014-09-01

    Corynebacterium spp. have proven their pathogenic potential in causing infections, particularly in the setting of immunosuppression and prosthetic devices. We conducted a PubMed literature review of all cases of Corynebacterium prosthetic device infections published in the English language through December 2013. The majority of cases involved peritoneal dialysis and central venous catheters, but prosthetic joints and central nervous system shunts/drains were also involved. The management of these cases in terms of retention or removal of the device was not uniform; however, the overall mortality remained the same among both groups. All of these prosthetic device infections pose potential problems in management when the device cannot be removed safely for the patient, especially with the lack of data on the pathogenicity of Corynebacterium species. However with better identification of species and sensitivities, successful treatment is possible even with retention of the device.

  10. Control of a powered prosthetic device via a pinch gesture interface

    Science.gov (United States)

    Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.

    2015-06-01

    A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.

  11. Surface EMG and intra-socket force measurement to control a prosthetic device

    Science.gov (United States)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  12. 78 FR 2647 - Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant

    Science.gov (United States)

    2013-01-14

    .... FDA-2012-N-0677] Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant AGENCY: Food...) is proposing to reclassify the blade- form endosseous dental implant, a preamendments class III... proposing to revise the classification of blade-form endosseous dental implants. DATES: Submit either...

  13. Quality Assurance in Custom Dental Devices: A Technologist's Perspective.

    Science.gov (United States)

    Griffin, Anthony

    2017-12-01

    Manufacturing of custom-made dental devices such as removable dentures, fixed prosthodontics and orthodontics are subject to the requirements of the Medical Devices Directive (MDD). Many dental laboratories often enhance these requirements by implementing quality assurance procedures that then provide enhanced consistency. this paper provides a dental technologist's view of some of the systems currently being used in dental laboratories to provide a quality assured product and associated issues.

  14. Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery.

    Science.gov (United States)

    Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter

    New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified

  15. A systematic review of prosthetic restoration in patients with shortened dental arches

    Directory of Open Access Journals (Sweden)

    Kenji Fueki

    2011-08-01

    Full Text Available The literature regarding the effect of prosthetic restoration in patients having distal extension edentulous space in posterior area (shortened dental arch: SDA is reviewed in the following article. Information retrieval followed a systematic approach using PubMed. Articles in English published between 1966 and March 2011 describing the outcome of treatment with various prostheses were evaluated. From the search results of 98 articles, 21 articles met the inclusion criteria. Treatment with removable partial dentures (RPDs improved masticatory function, patient satisfaction and oral health-related quality of life (OHRQoL. However, no significant difference was found in the outcomes between patients with RPDs and with cantilever fixed partial dentures (CFPDs. Caries developed more frequently after treatment with RPDs than CFPDs. The time to survival for CFPDs was not longer than that for RPDs, while more visits to maintain RPDs were required than for CFPDs. No significant difference was found in masticatory function, OHRQoL, and occlusal stability between patients with RPDs and those without restoration of missing molars. Consequently, treatment with RPDs for SDA seems to be less advantageous than CFPDs or no restoration for missing molars. Further research is required to validate treatment with implant-supported fixed partial dentures for SDA.

  16. 21 CFR 872.2050 - Dental sonography device.

    Science.gov (United States)

    2010-04-01

    ... § 872.9. (b) Dental sonography device for interpretation and diagnosis—(1) Identification. A dental sonography device for interpretation and diagnosis is an electrically powered device, intended to interpret temporomandibular joint sounds for the diagnosis of temporomandibular joint disorders and associated orofacial pain...

  17. A new prosthetic alignment device to read and record prosthesis alignment data.

    Science.gov (United States)

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Ali, Sadeeq; Davoodi Makinejad, Majid

    2017-12-01

    Prosthetic alignment is an essential process to rehabilitate patients with amputations. This study presents, for the first time, an invented device to read and record prosthesis alignment data. The digital device consists of seven main parts: the trigger, internal shaft, shell, sensor adjustment button, digital display, sliding shell, and tip. The alignment data were read and recorded by the user or a computer to replicate prosthesis adjustment for future use or examine the sequence of changes in alignment and its effect on the posture of the patient. Alignment data were recorded at the anterior/posterior and medial/lateral positions for five patients. Results show the high level of confidence to record alignment data and replicate adjustments. Therefore, the device helps patients readjust their prosthesis by themselves, or prosthetists to perform adjustment for patients and analyze the effects of malalignment.

  18. [Fragmentary osteotomy of maxilla back parts for dentoalveolar lengthening as preparation stage before dental prosthetics making on implants].

    Science.gov (United States)

    Seniuk, A N; Mokhirev, M A

    2010-01-01

    Conditions for dental implantation are not always ideal that decrease the method possibilities and makes surgeons-implantologists to resort to additional interventions in order to increase the hard and soft tissues volume in the region of the planned implantation. Considerably rare an implantologist comes across with abutment tissues surplus when considerable dentoalveolar lengthening happens with expressed diminution of interalveolar distance. Orthognatic surgery as the method of surgical correction of expressed dentoalveolar lengthening of some teeth group is the most effective when there is no possibility to such deformation elimination by other methods - orthodontic or prosthetic.

  19. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  20. A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants

    Directory of Open Access Journals (Sweden)

    Felipe Miguel Saliba

    2011-02-01

    Full Text Available OBJECTIVES: Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The present study proposes a method for evaluating the screw removal torque in an anti-rotational device independent way, creating an unscrewing load transfer to the entire assembly, not only to the screw. MATERIAL AND METHODS: Twenty hexagonal abutments without the hexagon in their bases were fixed with a screw to 20 dental implants. They were divided into two groups: Group 1 used titanium screws and Group 2 used titanium screws covered with a solid lubricant. A torque of 32 Ncm was applied to the screw and then a custom-made wrench was used for rotating the abutment counterclockwise, to loosen the screw. A digital torque meter recorded the torque required to loosen the abutment. RESULTS: There was a significant difference between the means of Group 1 (38.62±6.43 Ncm and Group 2 (48.47±5.04 Ncm, with p=0.001. CONCLUSION: This methodology was effective in comparing unscrewing torque values of the implant-abutment junction even with a limited sample size. It confirmed a previously shown significant difference between two types of screws.

  1. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment.

    Science.gov (United States)

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-09-25

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug

  2. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment

    Directory of Open Access Journals (Sweden)

    Yu-Jung Li

    2015-09-01

    Full Text Available A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis

  3. Pilot Study for OCT Guided Design and Fit of a Prosthetic Device for Treatment of Corneal Disease

    Directory of Open Access Journals (Sweden)

    Hong-Gam T. Le

    2012-01-01

    Full Text Available Purpose. To assess optical coherence tomography (OCT for guiding design and fit of a prosthetic device for corneal disease. Methods. A prototype time domain OCT scanner was used to image the anterior segment of patients fitted with large diameter (18.5–20 mm prosthetic devices for corneal disease. OCT images were processed and analyzed to characterize corneal diameter, corneal sagittal height, scleral sagittal height, scleral toricity, and alignment of device. Within-subject variance of OCT-measured parameters was evaluated. OCT-measured parameters were compared with device parameters for each eye fitted. OCT image correspondence with ocular alignment and clinical fit was assessed. Results. Six eyes in 5 patients were studied. OCT measurement of corneal diameter (coefficient of variation, %, cornea sagittal height (%, and scleral sagittal height (% is highly repeatable within each subject. OCT image-derived measurements reveal strong correlation between corneal sagittal height and device corneal height ( and modest correlation between scleral and on-eye device toricity (. Qualitative assessment of a fitted device on OCT montages reveals correspondence with slit lamp images and clinical assessment of fit. Conclusions. OCT imaging of the anterior segment is suitable for custom design and fit of large diameter (18.5–20 mm prosthetic devices used in the treatment of corneal disease.

  4. [Prosthetic replacement of missing teeth. Indications for fixed and removable dental prostheses

    NARCIS (Netherlands)

    Witter, D.J.; Gerritsen, A.E.; Baat, C. de; Creugers, N.H.J.

    2014-01-01

    Prosthetic replacement of missing teeth aims to improve health. This can be achieved by improving the patient's well-being and quality of life and by restoring the biological balance in terms ofocclusal and mandibular stability in the occlusal and the orofacial system. In occlusal systems with a

  5. Prosthetic Jamming Terminal Device: A Case Study of Untethered Soft Robotics.

    Science.gov (United States)

    Cheng, Nadia; Amend, John; Farrell, Todd; Latour, Debra; Martinez, Carlos; Johansson, Jen; McNicoll, Anthony; Wartenberg, Marek; Naseef, Samuel; Hanson, William; Culley, William

    2016-12-01

    This article illuminates the major and often overlooked challenge of untethering soft robotic systems through the context of recent work, in which soft robotic gripper technology enabled by jamming of granular media was applied to a prosthetic jamming terminal device (PJTD). The PJTD's technical and market feasibility was evaluated in a pilot study with two upper-limb amputees. A PJTD prototype was tested against a commercial device (Motion Control electric terminal service with a one degree-of-freedom pinching mechanism) using two existing hand function tests: the first quantified the device's speed in picking and placing small blocks and the second evaluated a person's ability to perform activities of daily living (ADLs). The PJTD prototype performed slightly slower than its commercial counterpart in the first test. While both participants successfully completed all the ADLs with both devices in the second test, the commercial device scored marginally higher. Results suggested that PJTD can have potential benefits over existing terminal devices, such as providing the capability to firmly grasp tools due to the ability of PJTD to conform to arbitrary surfaces and reducing compensatory shoulder movements due to its axisymmetric design. Some downsides were that users reported fatigue while operating the PJTD, as most operations require pushing the PJTD against target objects to adequately conform to them. The greatest drawback for the PJTD is also a major roadblock preventing a number of soft robotic research projects from making an impact in real-world applications: pneumatic technology required for operating the PJTD is currently too large and heavy to enable compact untethered operation.

  6. 21 CFR 872.3070 - Dental amalgam, mercury, and amalgam alloy.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam, mercury, and amalgam alloy. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3070 Dental amalgam, mercury... elemental mercury, supplied as a liquid in bulk, sachet, or predosed capsule form, and amalgam alloy...

  7. Antibiotic prophylaxis for dental treatment after prosthetic joint replacement: exploring the orthopaedic surgeon's opinion

    Directory of Open Access Journals (Sweden)

    Clare M. McNally, MPhil(Dent

    2016-09-01

    Conclusions: Australian orthopaedic surgeons continue to recommend antibiotic prophylaxis for dental treatment. The recording of PJI in relation to dental procedures into clinical registries would enable the development of consistent guidelines between professional groups responsible for the care of this patient group.

  8. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  9. The immediate insertion, loading and provisional prosthetic restoration of dental implants.

    Science.gov (United States)

    Sârbu, I

    2008-01-01

    The immediate insertion and loading of dental implants although used in the past as an alternative method for the surgical phase of the dental implant treatment is today becoming more and more popular due to its immediate and spectacular results. With information on bone density and a careful patient selection, this method has increased chances of success. Its main advantage is the high degree of patient comfort with a great aesthetic effect. This article presents the theoretical and practical technique used on two clinical cases of dental implantation and their outcome.

  10. Prevalence of xerostomia and hyposalivation and their association with quality of life in elderly patients in dependence on dental status and prosthetic rehabilitation: a pilot study.

    Science.gov (United States)

    Hahnel, Sebastian; Schwarz, Simone; Zeman, Florian; Schäfer, Lina; Behr, Michael

    2014-06-01

    The aims of this pilot study were to investigate the prevalence of xerostomia and hyposalivation and their impact on quality of life in a cohort of elderly patients including dental status and the character of potential prosthetic restorations as independent variables. Patients aged 60 years or older without any objective or subjective need for prosthodontic treatment taking part in a regular recall programme were included in the trial. Quality of life was assessed using the German version of the GOHAI; prevalence and severity of xerostomia was investigated using the shortened version of the Xerostomia Inventory (XI). Stimulated salivary flow rate was determined using a sialometric approach. Dental status and the character of prosthetic restorations (no/fixed restorations and removable but tooth-supported dentures vs. gum-supported dentures) were assessed in a clinical examination by experienced dentists specialized in prosthodontic treatment. A total of 68 patients were included in the trial; a prevalence of xerostomia of 16% and a prevalence of hyposalivation of 31% were identified. The quality of life in the study cohort decreased significantly as a function of xerostomia severity but not salivary flow; moreover, a significant impact of the number of teeth/implants in the upper jaw and the presence of gum-supported dentures in both jaws on GOHAI scores could be identified. Within the limitations of a pilot study, the results support the assumption that the quality of life in elderly patients is particularly related to their subjective perception of xerostomia. A decline in salivary flow, the dental status and the character of prosthetic restorations appear to play a subordinate role for the quality of life in elderly patients. The quality of life in elderly patients may be severely diminished due to an increased subjective perception of dry mouth. Dental treatment should focus on alleviating xerostomia, whereas the impact of dental status and prosthetic

  11. Cost-effectiveness of antibiotic prophylaxis for dental patients with prosthetic joints: Comparisons of antibiotic regimens for patients with total hip arthroplasty.

    Science.gov (United States)

    Skaar, Daniel D; Park, Taehwan; Swiontkowski, Marc F; Kuntz, Karen M

    2015-11-01

    Clinician uncertainty concerning the need for antibiotic prophylaxis to prevent prosthetic joint infection (PJI) after undergoing dental procedures persists. Improved understanding of the potential clinical and economic risks and benefits of antibiotic prophylaxis will help inform the debate and facilitate the continuing evolution of clinical management guidelines for dental patients with prosthetic joints. The authors developed a Markov decision model to compare the lifetime cost-effectiveness of alternative antibiotic prophylaxis strategies for dental patients aged 65 years who had undergone total hip arthroplasty (THA). On the basis of the authors' interpretation of previous recommendations from the American Dental Association and American Academy of Orthopaedic Surgeons, they compared the following strategies: no prophylaxis, prophylaxis for the first 2 years after arthroplasty, and lifetime prophylaxis. A strategy of foregoing antibiotic prophylaxis before dental visits was cost-effective and resulted in lower lifetime accumulated costs ($11,909) and higher accumulated quality-adjusted life years (QALYs) (12.375) when compared with alternative prophylaxis strategies. The results of Markov decision modeling indicated that a no-antibiotic prophylaxis strategy was cost-effective for dental patients who had undergone THA. These results support the findings of case-control studies and the conclusions of an American Dental Association Council on Scientific Affairs report that questioned general recommendations for antibiotic prophylaxis before dental procedures. The results of cost-effectiveness decision modeling support the contention that routine antibiotic prophylaxis for dental patients with total joint arthroplasty should be reconsidered. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  12. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Trottier, Mikaël; Tessier, Michel

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, mainly in the most difficult cases. Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography (WBC SPECT/CT) have been studied in these situations. In their 2015 guidelines for the management of infective endocarditis, the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE, but not CIED infection since the data were judged insufficient at the moment. This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE, and describes the technical aspects of cardiac radionuclide imaging. It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE, the limitations of these tests, and potential areas of future research. PMID:27721936

  13. Preoperative CT analysis of the mandible and maxilla for permanent dental prosthetic implantation

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Rhodes, M.L.; Schwarz, M.; Chafetz, N.I.

    1987-01-01

    The Branemark technique for permanently implanting dental prostheses is becoming universally accepted. The surgeon requires detailed knowledge of the cross-sectional anatomy of the alveolar ridges and inferior alveolar nerve for safe placement of the titanium fixtures. Axial CT scans of the mandible and maxilla, with oblique and panoramic CT reformations, were obtained in more than 100 patients. This report describes the anatomic variations in the maxilla and mandible as they relate to dental implantation surgery. The authors demonstrate the utility of this technique in preoperative surgical planning and postoperative evaluation

  14. Development and testing of new upper-limb prosthetic devices: research designs for usability testing.

    Science.gov (United States)

    Resnik, Linda

    2011-01-01

    The purposes of this article are to describe usability testing and introduce designs and methods of usability testing research as it relates to upper-limb prosthetics. This article defines usability, describes usability research, discusses research approaches to and designs for usability testing, and highlights a variety of methodological considerations, including sampling, sample size requirements, and usability metrics. Usability testing is compared with other types of study designs used in prosthetic research.

  15. Acceptance of e-learning devices by dental students.

    Science.gov (United States)

    Schulz, Peter; Sagheb, Keyvan; Affeldt, Harald; Klumpp, Hannah; Taylor, Kathy; Walter, Christian; Al-Nawas, Bilal

    2013-01-01

    E-Learning programs and their corresponding devices are increasingly employed to educate dental students during their clinical training. Recent progress made in the development of e-learning software as well as in hardware (computers, tablet PCs, smartphones) caused us to more closely investigate into the habits of dental students in dealing with these learning techniques. Dental students during their clinical training attended a survey compiled in cooperation with biostatisticians. The questionnaire probands were asked to complete based on previous surveys of similar subjects, allowing single as well as multiple answers. The data, which were obtained with respect to the learning devices students commonly employ, were compared with their internet learning activities. The e-learning devices utilized are of heterogeneous brands. Each student has access to at least one hardware type suitable for e-learning. All students held mobile devices, about 90 percent employed laptops, and about 60 percent possess smartphones. Unexceptional all participants of the survey acknowledged an unlimited internet access. In contrast, only 16 percent of students utilized tablet PCs. A detailed analysis of the survey outcome reveals that an increasing use of mobile devices (tablet PC, smartphone) facilitates internet learning activities while at the same time utilization of computers (desktop, laptop) declines. Dental students overwhelmingly accept e-learning during their clinical training. Students report outstanding preconditions to conduct e-learning as both their access to hardware and to the internet is excellent. Less satisfying is the outcome of our survey regarding the utilization of e-learning programs. Depending of the hardware employed only one-third to barely one-half of students comprise learning programs.

  16. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    Science.gov (United States)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  17. 75 FR 16511 - Pentron Clinical Technologies, a Wholly-Owned Subsidiary of Kerr Dental/Sybron Dental...

    Science.gov (United States)

    2010-04-01

    ... produce dental materials such as dental prosthetics, dental composites, dental impressions, dental... materials such as dental prosthetics, dental composites, dental impressions, dental adhesives, and other... Technologies, a Wholly-Owned Subsidiary of Kerr Dental/Sybron Dental Specialities, Formally Known as Customedix...

  18. Dental enamel defect diagnosis through different technology-based devices.

    Science.gov (United States)

    Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini

    2018-06-01

    Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.

  19. Selective interference with pacemaker activity by electrical dental devices.

    Science.gov (United States)

    Miller, C S; Leonelli, F M; Latham, E

    1998-01-01

    We sought to determine whether electromagnetic interference with cardiac pacemakers occurs during the operation of contemporary electrical dental equipment. Fourteen electrical dental devices were tested in vitro for their ability to interfere with the function of two Medtronics cardiac pacemakers (one a dual-chamber, bipolar Thera 7942 pacemaker, the other a single-chamber, unipolar Minix 8340 pacemaker). Atrial and ventricular pacemaker output and electrocardiographic activity were monitored by means of telemetry with the use of a Medtronics 9760/90 programmer. Atrial and ventricular pacing were inhibited by electromagnetic interference produced by the electrosurgical unit up to a distance of 10 cm, by the ultrasonic bath cleaner up to 30 cm, and by the magnetorestrictive ultrasonic scalers up to 37.5 cm. In contrast, operation of the amalgamator, electric pulp tester, composite curing light, dental handpieces, electric toothbrush, microwave oven, dental chair and light, ENAC ultrasonic instrument, radiography unit, and sonic scaler did not alter pacing rate or rhythm. These results suggest that certain electrosurgical and ultrasonic instruments may produce deleterious effects in medically fragile patients with cardiac pacemakers.

  20. SU-E-T-512: Evaluation of Treatment Planning Dose Calculation Accuracy at the Interface of Prosthetic Devices.

    Science.gov (United States)

    Paulu, D; Alaei, P

    2012-06-01

    To evaluate the ability of treatment planning algorithm to accurately predict dose delivered at the interface of high density implanted devices. A high density (7.6 g/cc) Cobalt-Chromium-Molybdenum hip prosthesis was molded into an epoxy-based cylindrical leg phantom. The phantom was designed to be separated in half to access the prosthesis and to place the TLDs. Using MVCT to image the apparatus, a simple treatment plan was developed using the Philips Pinnacle treatment planning system. Wires were placed in the molded epoxy to allow for accurate definition of measurement sites (TLD positions) along the surface of the prosthesis. Micro-cube TLDs (1 mm 3 ) were placed at six measurement locations for which the dose had been calculated by the treatment planning system. An Elekta Synergy linear accelerator was used to deliver a 400 cGy plan to the phantom with 6 MV photons in a single fraction. A total of four 10 cm × 21 cm fields were used at 0, 90, 180, and 270 degree gantry rotations. Initial results indicate that the measured dose is 7-17% lower than the dose calculated by the treatment planning system. Further study using high energy beams are also in progress. Initial results indicate that the treatment planning system does predict the dose near a high density prosthetic device within 10-15% but underestimates the dose. The results of this study could help in designing treatment plans which would reduce the uncertainty of the dose delivered in the vicinity of prosthetic hip implants and similar devices. © 2012 American Association of Physicists in Medicine.

  1. Unilateral lower-limb loss: prosthetic device use and functional outcomes in servicemembers from Vietnam war and OIF/OEF conflicts.

    Science.gov (United States)

    Gailey, Robert; McFarland, Lynne V; Cooper, Rory A; Czerniecki, Joseph; Gambel, Jeffrey M; Hubbard, Sharon; Maynard, Charles; Smith, Douglas G; Raya, Michele; Reiber, Gayle E

    2010-01-01

    Rehabilitation goals following major combat-associated limb loss in World War II and the Vietnam war focused on treatment of the injury and a return to civilian life. The goal for Operation Iraqi Freedom/Operation Enduring Freedom (OIF/OEF) servicemembers is to restore function to the greatest possible degree and, if they desire, return them to Active Duty, by providing them with extensive rehabilitation services and a variety of prosthetic devices. Our study determines the usefulness of these diverse types of prosthetic devices for restoring functional capability and documents prosthesis use and satisfaction. We compare servicemembers and veterans with major combat-associated unilateral lower-limb loss: 178 from the Vietnam war and 172 from OIF/OEF conflicts. Of survey participants with unilateral lower-limb loss, 84% of the Vietnam group and 94% of the OIF/OEF group currently use at least one prosthetic device. Reasons for rejection varied by type of device, but common reasons were pain, prosthesis too heavy, and poor fit. Abandonment is infrequent (11% Vietnam group, 4% OIF/OEF group). Future efforts should aim to improve prosthetic-device design, decrease pain, and improve quality of life for these veterans and servicemembers.

  2. Pre-prosthetic surgery: Mandible

    Directory of Open Access Journals (Sweden)

    Veeramalai Naidu Devaki

    2012-01-01

    Full Text Available Pre-prosthetic surgery is that part of oral and maxillofacial surgery which restores oral function and facial form. This is concerned with surgical modification of the alveolar process and its surrounding structures to enable the fabrication of a well-fitting, comfortable, and esthetic dental prosthesis. The ultimate goal of pre-prosthetic surgery is to prepare a mouth to receive a dental prosthesis by redesigning and smoothening bony edges.

  3. Case Study on Human Walking during Wearing a Powered Prosthetic Device: Effectiveness of the System “Human-Robot”

    Directory of Open Access Journals (Sweden)

    Svetlana Grosu

    2014-01-01

    Full Text Available It is known that force exchanges between a robotic assistive device and the end-user have a direct impact on the quality and performance of a particular movement task. This knowledge finds a special reflective importance in prosthetic industry due to the close human-robot collaboration. Although lower-extremity prostheses are currently better able to provide assistance as their upper-extremity counterparts, specific locomotion problems still remain. In a framework of this contribution the authors introduce the multibody dynamic modelling approach of the transtibial prosthesis wearing on a human body model. The obtained results are based on multibody dynamic simulations against the real experimental data using AMP-Foot 2.0, an energy efficient powered transtibial prosthesis for actively assisted walking of amputees.

  4. 78 FR 9010 - Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis

    Science.gov (United States)

    2013-02-07

    .... FDA-2012-N-1239] Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis AGENCY... condyle prostheses into class III, based on the recommendation of a Dental Products Panel (the Panel... Administration, Dental Products Advisory Panel Meeting Transcript, February 12, 1997; http://www.accessdata.fda...

  5. Post-operative orbital imaging: a focus on implants and prosthetic devices

    International Nuclear Information System (INIS)

    Adams, Ashok; Mankad, Kshitij; Poitelea, Cornelia; Verity, David H.; Davagnanam, Indran

    2014-01-01

    Accurate interpretation of orbital imaging in the presence of either orbital implants requires a sound knowledge of both the surgical approach used and the imaging characteristics of the implanted devices themselves. In this article, the radiological appearance of the various devices used in ophthalmology, and their relationship to other orbital structures, is reviewed. In addition, the intended anatomical location, function of these devices, and clinical indications for their use are provided. (orig.)

  6. Reliability and accuracy of four dental shade-matching devices.

    Science.gov (United States)

    Kim-Pusateri, Seungyee; Brewer, Jane D; Davis, Elaine L; Wee, Alvin G

    2009-03-01

    There are several electronic shade-matching instruments available for clinical use, but the reliability and accuracy of these instruments have not been thoroughly investigated. The purpose of this in vitro study was to evaluate the reliability and accuracy of 4 dental shade-matching instruments in a standardized environment. Four shade-matching devices were tested: SpectroShade, ShadeVision, VITA Easyshade, and ShadeScan. Color measurements were made of 3 commercial shade guides (Vitapan Classical, Vitapan 3D-Master, and Chromascop). Shade tabs were placed in the middle of a gingival matrix (Shofu GUMY) with shade tabs of the same nominal shade from additional shade guides placed on both sides. Measurements were made of the central region of the shade tab positioned inside a black box. For the reliability assessment, each shade tab from each of the 3 shade guide types was measured 10 times. For the accuracy assessment, each shade tab from 10 guides of each of the 3 types evaluated was measured once. Differences in reliability and accuracy were evaluated using the Standard Normal z test (2 sided) (alpha=.05) with Bonferroni correction. Reliability of devices was as follows: ShadeVision, 99.0%; SpectroShade, 96.9%; VITA Easyshade, 96.4%; and ShadeScan, 87.4%. A significant difference in reliability was found between ShadeVision and ShadeScan (P=.008). All other comparisons showed similar reliability. Accuracy of devices was as follows: VITA Easyshade, 92.6%; ShadeVision, 84.8%; SpectroShade, 80.2%; and ShadeScan, 66.8%. Significant differences in accuracy were found between all device pairs (Preliability (over 96%), indicating predictable shade values from repeated measurements. However, there was more variability in accuracy among devices (67-93%), and differences in accuracy were seen with most device comparisons.

  7. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Institute of Scientific and Technical Information of China (English)

    Jean-Fran?ois Sarrazin; Fran?ois Philippon; Mika?l Trottier; Michel Tessier

    2016-01-01

    Cardiovascular implantable electronic device(CIED) infection and prosthetic valve endocarditis(PVE) remain a diagnostic challenge.Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE.Over the past few years,cardiac radionuclide imaging has gained a key role in the diagnosis of these patients,and in assessing the need for surgery,mainly in the most difficult cases.Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography(WBC SPECT/CT) have been studied in these situations.In their 2015 guidelines for the management of infective endocarditis,the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE,but not CIED infection since the data were judged insufficient at the moment.This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE,and describes the technical aspects of cardiac radionuclide imaging.It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE,the limitations of these tests,and potential areas of future research.

  8. Prosthetic Rehabilitation of a Patient with Mandibular Resection Prosthesis Using Mini Dental Implants (MDIs) – Case Report

    OpenAIRE

    Vojvodić, Denis; Čelebić, Asja; Mehulić, Ketij; Žabarović, Domagoj

    2012-01-01

    Physical disfigurement and functional impairments associated with facial trauma are a challenge to a prosthodontist, because even novel sophisticated surgical reconstructive techniques fail to provide adequate support for dental resection prosthesis. Therefore, different endosseous implants are often used as prosthesis-supporting elements. Manufacturers of dental implants have recently presented mini dental implants (MDIs) with diameter of only 1.8–2.4 mm. These implants allow very suitable p...

  9. Prevention of dental anomalies in children by prosthetics defects hard tooth tissues and dentitions: the need to possibilities

    Directory of Open Access Journals (Sweden)

    Suetenkov D.Ye.

    2011-03-01

    Full Text Available This article presents the possibility of restore the function and anatomy of the tooth and replacement of defects of dentition by prosthesis in children under the removable bite as a method of prevention of dentoalveolar anomalies. Identified the need for prosthetic treatment of children and the willingness of dentists as primary health care professional to address the problems identified. A clinical analysis of complex treatment of defects in the teeth with fixed restorations

  10. A case study of technology transfer: Rehabilitative engineering at Rancho Los Amigos Hospital. [prosthetic devices engineering

    Science.gov (United States)

    Hildred, W.

    1973-01-01

    The transfer of NASA technolgy to rehabilitative applications of artificial limbs is studied. Human factors engineering activities range from orthotic manipulators to tiny dc motors and transducers to detect and transmit voluntary control signals. It is found that bicarbon implant devices are suitable for medical equipment and artificial limbs because of their biological compatibility with human body fluids and tissues.

  11. Safety and effectiveness considerations for clinical studies of visual prosthetic devices

    Science.gov (United States)

    Cohen, Ethan D.

    2007-03-01

    With the advent of new designs of visual prostheses for the blind, FDA is faced with developing guidance for evaluating their engineering, safety and patient performance. Visual prostheses are considered significant risk medical devices, and their use in human clinical trials must be approved by FDA under an investigation device exemption (IDE). This paper contains a series of test topics and design issues that sponsors should consider in order to assess the safety and efficacy of their device. The IDE application includes a series of pre-clinical and clinical data sections. The pre-clinical section documents laboratory, animal and bench top performance tests of visual prostheses safety and reliability to support a human clinical trial. The materials used in constructing the implant should be biocompatible, sterile, corrosion resistant, and able to withstand any forces exerted on it during normal patient use. The clinical data section is composed of items related to patient-related evaluation of device performance. This section documents the implantation procedure, trial design, statistical analysis and how visual performance is assessed. Similar to cochlear implants, a visual prosthesis is expected to last in the body for many years, and good pre-clinical and clinical testing will help ensure its safety, durability and effectiveness.

  12. Dental Amalgam

    Science.gov (United States)

    ... Products and Medical Procedures Dental Devices Dental Amalgam Dental Amalgam Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Dental amalgam is a dental filling material which is ...

  13. Diagnosis of prosthetic joint infection with alpha-defensin using a lateral flow device: a multicentre study.

    Science.gov (United States)

    Berger, P; Van Cauter, M; Driesen, R; Neyt, J; Cornu, O; Bellemans, J

    2017-09-01

    The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS). A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery. Based on the MSIS criteria, 34 patients (28%) would have had a PJI, and 87 patients had no PJI. Testing with the lateral flow device had a sensitivity of 97.1% (95% confidence intervals (CI) 84.5 to 99.9) and a specificity of 96.6% (95% CI 90.3 to 99.2). The positive predictive value was 91.7% (95% CI 77.7% to 98.3), and the negative predictive value was 98.8% (95% CI 93.6 to 99.9). Receiver operator characteristics analysis demonstrated an area under the curve for the Synovasure test of 0.97 (95% CI 0.93 to 1.00). Our findings suggest that the Synovasure test has an excellent diagnostic performance to confirm or reject the diagnosis of a PJI. The results are promising for the care of the painful or problematic knee and hip joint arthroplasty and the test should be considered as part of the diagnostic toolbox for PJIs. Cite this article: Bone Joint J 2017;99-B:1176-82. ©2017 The British Editorial Society of Bone & Joint Surgery.

  14. 78 FR 79308 - Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis

    Science.gov (United States)

    2013-12-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 872 [Docket No. FDA-2012-N-1239] Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis AGENCY... delegated to the Commissioner of Food and Drugs, 21 CFR part 872 is amended as follows: PART 872--DENTAL...

  15. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    Science.gov (United States)

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Psychophysical testing of visual prosthetic devices: a call to establish a multi-national joint task force

    Science.gov (United States)

    Rizzo, Joseph F., III; Ayton, Lauren N.

    2014-04-01

    Recent advances in the field of visual prostheses, as showcased in this special feature of Journal of Neural Engineering , have led to promising results from clinical trials of a number of devices. However, as noted by these groups there are many challenges involved in assessing vision of people with profound vision loss. As such, it is important that there is consistency in the methodology and reporting standards for clinical trials of visual prostheses and, indeed, the broader vision restoration research field. Two visual prosthesis research groups, the Boston Retinal Implant Project (BRIP) and Bionic Vision Australia (BVA), have agreed to work cooperatively to establish a multi-national Joint Task Force. The aim of this Task Force will be to develop a consensus statement to guide the methods used to conduct and report psychophysical and clinical results of humans who receive visual prosthetic devices. The overarching goal is to ensure maximum benefit to the implant recipients, not only in the outcomes of the visual prosthesis itself, but also in enabling them to obtain accurate information about this research with ease. The aspiration to develop a Joint Task Force was first promulgated at the inaugural 'The Eye and the Chip' meeting in September 2000. This meeting was established to promote the development of the visual prosthetic field by applying the principles of inclusiveness, openness, and collegiality among the growing body of researchers in this field. These same principles underlie the intent of this Joint Task Force to enhance the quality of psychophysical research within our community. Despite prior efforts, a critical mass of interested parties could not congeal. Renewed interest for developing joint guidelines has developed recently because of a growing awareness of the challenges of obtaining reliable measurements of visual function in patients who are severely visually impaired (in whom testing is inherently noisy), and of the importance of

  17. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  18. Prosthetics in Paediatric Dentistry

    Directory of Open Access Journals (Sweden)

    Vulićević Zoran

    2017-07-01

    Full Text Available Premature loss of teeth in children may lead to both functional and esthetic problems. Missing teeth in both anterior and posterior regions may cause malfunctions in mastication and proper pronunciation. If the missing teeth are not replaced, further complications may occur, including adjacent tooth migration, loss of alveolar bone, and irregular occlusion. Considering the sensitive nature of children, loss of teeth may cause the development of insecurities and low self esteem problems. Due to dynamic nature of growth in children and adolescents, prosthetic appliances must not hinder development of orofacial system, and must meet adequate esthetic and functional standards. Dental prosthetic appliances in paediatrics must be planned with respect to the special conditions that led to tooth loss or damage. Multi-disciplinary approach is needed, under constant supervision of paediatric dentist and orthodontist, as well as regular checkups with clinical and radiographical examinations.

  19. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Minatel, Lurian [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Verri, Fellippo Ramos [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); Kudo, Guilherme Abu Halawa [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); and others

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  20. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    International Nuclear Information System (INIS)

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo

    2017-01-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  1. The effect of surface treatments on the microroughness of laser-sintered and vacuum-cast base metal alloys for dental prosthetic frameworks.

    Science.gov (United States)

    Castillo-Oyagüe, Raquel; Osorio, Raquel; Osorio, Estrella; Sánchez-Aguilera, Fátima; Toledano, Manuel

    2012-09-01

    This study aimed to evaluate the effect of four chemomechanical surface treatments on the surface average microroughness and profile of laser-sintered and vacuum-cast dental prosthetic structures. Square-shaped blocks (10 mm × 10 mm × 1.5 mm) were prepared as follows: (1) laser-sintered CoCr (L) (ST2724G); (2) cast Co-Cr (C) (Gemium-cn); and (3) cast Ni-Cr-Ti (T) (Tilite). Specimens of each alloy group were randomly divided into five subgroups (n = 10 each), depending on the conditioning method used: (1) no treatment (control); (2) sandblasting (125 μm Al₂O₃-particles); (3) silica coating (50 μm silica-modified Al₂O₃-particles); (4) oxidation; and (5) oxidation plus opacification. Subgroups 2 and 3 represent "inner" pretreatments proposed for ceramometal restorations to improve the metal surface area available for luting cements. Subgroups 4 and 5 are the "outer" pretreatments required for bonding the aesthetic veneering ceramics to the underlying metal frameworks. Average surface roughness (Ra/μm) was determined using a surface profilometer. Data were analyzed by two-way ANOVA and Student-Newman-Keuls tests (α = 0.05). Metal surface topography was SEM-analyzed. Despite the inner pretreatment applied, L samples resulted in the highest microroughness (P < 0.001), whereas sandblasting produced a surface-smoothing effect in cast specimens. After oxidation, a significant increase in surface roughness occurred in all groups compared with controls, L specimens being the roughest (P < 0.001). Opacification caused a flattening effect of all oxidized structures; all opacified groups resulting in similar microroughness. Laser sintering of Co-Cr enhances the roughness of metal structures, which may improve the frameworks' microretention of the cements, and of the opaquer before the copings are veneered with the aesthetic ceramics. Copyright © 2012 Wiley Periodicals, Inc.

  2. Advanced Implant-Prosthetic Rehabilitation: How to Obtain a Correct Restoration of Both Functions and Aesthetics in Patients with Complex Combined Dental and Maxillofacial Trauma: A Case Report and Topical Review of the Literature.

    Science.gov (United States)

    Figliuzzi, M M; Giudice, A; Fortunato, L

    2017-01-01

    Aim . This study aims to explain the main steps that characterize the implant-prosthetic rehabilitation in complex combined dental and maxillofacial trauma. Material and Methods . A 20-year-old patient reported an extensive facial trauma which also involved the alveolar process of the maxillary bone. The patient reported a maxillofacial fracture and the loss of teeth 1.3, 1.2, 1.1, and 2.1. A "Le Fort" type 2 fracture was also reported, with the malar bone involvement. After reduction and containment of bone fractures, through appropriate mounting plates, appropriate functional and aesthetic rehabilitation of the patient were replaced thanks to a temporary removable prosthesis. After 6 months, the patient performed numerous clinical investigations, aimed at a proper planning of implant-prosthetic rehabilitation of the upper dental arch. Conclusion . With the planning of the case, as well as respecting the surrounding biological structures, the surgery of implants can be carried out with the most appropriate procedure. Lastly, new dental implants with highly bioactive surfaces have been developed, providing an excellent and rapid bone integration.

  3. About Dental Amalgam Fillings

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...

  4. Laser welding by dental Nd:YAG device

    Science.gov (United States)

    Fornaini, Carlo; Bertrand, Caroline; Merigo, Elisabetta; Bonanini, Mauro; Rocca, Jean-Paul; Nammour, Samir

    2009-06-01

    Welding laser was introduced in jewellery during years 70 and, just after, was successfully used also by dental technicians. Welding laser gives a great number of advantages, versus traditional welding and, for this reason, this procedure had a great diffusion in the technician laboratories and stimulated the companies to put in the market more and more evolutes appliances. Some aspects, such great dimensions, high costs and delivery system today still characterize these machines by fixed lenses, which have strictly limited its use only to technician laboratories. The aim of this study is to demonstrate the possibility, by using a fibber-delivered laser normally utilized in the dental office, to make, by dentist himself in his office, welding on different metals and to evaluate advantages and possibilities of this new technique.

  5. 18F-FDG-PET/CT angiography in the diagnosis of infective endocarditis and cardiac device infection in adult patients with congenital heart disease and prosthetic material.

    Science.gov (United States)

    Pizzi, María N; Dos-Subirà, L; Roque, Albert; Fernández-Hidalgo, Nuria; Cuéllar-Calabria, Hug; Pijuan Domènech, Antonia; Gonzàlez-Alujas, María T; Subirana-Domènech, M T; Miranda-Barrio, B; Ferreira-González, Ignacio; González-López, Juan J; Igual, Albert; Maisterra-Santos, Olga; García-Dorado, David; Castell-Conesa, Joan; Almirante, Benito; Escobar Amores, Manuel; Tornos, Pilar; Aguadé-Bruix, Santiago

    2017-12-01

    Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18 F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  6. Prosthetic Engineering

    Science.gov (United States)

    ... the household and community environments may lead to falls and injuries. This research aims to develop an ankle that can invert and evert and thereby control the center of pressure under the prosthetic foot; enhancing balance and stability of lower limb amputees. Foot-Ankle ...

  7. Theoretical study on the mechanics of the conjunct gnatoprothetic devices in the context of occlusive function rehabilitation.

    Science.gov (United States)

    Popescu, M R; Trană, F; Manolea, H; Rauten, Ane-Marie; Șurlin, Petra; Dragomir, L P

    2014-01-01

    The partially intercalated edentation offers the practitioner the possibility of the functional rehabilitation of the dental arcades through conjunct gnato-prosthetic devices. The functions of the dento-maxilar device, disturbed by the presence of edentation, require a treatment approach so that, without pre-planning or estimating, the result can lead most of the times to failure in terms of functionality. Clinical evaluation associated with pre- and proprosthetic treatment can also impose, in some situations the evaluation of the dental units involved in prosthetic rehabilitation. The association and implementation of the prosthetic construction in the occlusive-articular ensemble, as well as the counterbalancing of the mastication forces per dental unit and whole interarch system, linked to the distribution of the forces at the level of the pillar teeth and prosthetic construction, represent the goal of this theoretical study.

  8. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  9. Advances in dental local anesthesia techniques and devices: An update

    Science.gov (United States)

    Saxena, Payal; Gupta, Saurabh K.; Newaskar, Vilas; Chandra, Anil

    2013-01-01

    Although local anesthesia remains the backbone of pain control in dentistry, researches are going to seek new and better means of managing the pain. Most of the researches are focused on improvement in the area of anesthetic agents, delivery devices and technique involved. Newer technologies have been developed that can assist the dentist in providing enhanced pain relief with reduced injection pain and fewer adverse effects. This overview will enlighten the practicing dentists regarding newer devices and methods of rendering pain control comparing these with the earlier used ones on the basis of research and clinical studies available. PMID:24163548

  10. Advances in dental local anesthesia techniques and devices: An update.

    Science.gov (United States)

    Saxena, Payal; Gupta, Saurabh K; Newaskar, Vilas; Chandra, Anil

    2013-01-01

    Although local anesthesia remains the backbone of pain control in dentistry, researches are going to seek new and better means of managing the pain. Most of the researches are focused on improvement in the area of anesthetic agents, delivery devices and technique involved. Newer technologies have been developed that can assist the dentist in providing enhanced pain relief with reduced injection pain and fewer adverse effects. This overview will enlighten the practicing dentists regarding newer devices and methods of rendering pain control comparing these with the earlier used ones on the basis of research and clinical studies available.

  11. IN VITRO TESTING – AN ESENTIAL METHOD FOR EVALUATING THE PERFORMANCE OF DENTAL MATERIALS AND DEVICES

    Directory of Open Access Journals (Sweden)

    Anca VIŢALARIU

    2015-06-01

    Full Text Available Dentistry is unique among biomaterials specialties as to the large variety of materials used, and nature of the challenges they must resist. Intra-oral service demands materials adapted to a warm and moist environment, resisting the attack of digestive acids and enzymes. The materials subjected to mechanical forces should preserve their strength, fatigue and wear characteristics, for accomplishing their function. The wide range of materials available for restorative dentistry demands knowledge of their relative strengths and trade-offs, and offers the opportunity for many interesting lines of research. The spectrum extensively ranges from elastic impression materials to extremely stiff metal and ceramic appliances, so that familiarity with a variety of mechanical testing situations is required from a well-rounded dental materials laboratory. Evaluating the mechanical and wear characteristics of dental restorative materials and analyzing the durability of adhesives is critical to the development of improved dental devices

  12. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  13. X-ray pick-up device for dental radiography

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    The X-ray tube has got a tabular extension at the front end of which a W-shaped target is mounted. The target hit by electrons emits X-radiation passing through a ceramic window in the surface area. The extension can be inserted into the mouth opening of the patient. For holding down the tongue and for shielding purposes it has got a device shaped like a sleeve with diverging wings fastened to it. Thex leave the ceramic window uncovered. (orig.) [de

  14. Investigation of the medical applications of the unique biocarbons developed by NASA. [compatibility of percutaneous prosthetic carbon devices

    Science.gov (United States)

    Mooney, V.

    1973-01-01

    The biocompatibility of percutaneous endoskeletal fixation devices made from carbon compounds, and their applications are considered. The clinical application of these carbons to solve human problems is demonstrated and the nature of myoelectric simulation by carbon implants is studied.

  15. Evaluation of a new device for sterilizing dental high-speed handpieces

    DEFF Research Database (Denmark)

    Larsen, T; Andersen, H K; Fiehn, N E

    1997-01-01

    Dental high-speed turbines and handpieces can take up and expel microorganisms during operation and thus need regular sterilization. This study established a method for validating devices used to sterilize high-speed turbines and handpieces. The air and water channels and turbine chambers were...... contaminated with suspensions of Streptococcus salivarius or endospores of Bacillus stearothermophilus. The effect of flushing and/or autoclaving performed by a new device combining both procedures was evaluated by counting the number of viable bacteria recovered from these devices. Further, the effect...... on clinically used handpieces was evaluated. In an initial experiment, the device partially reduced S. salivarius, and the endospores survived. In a second experiment, a 5 to 6 log reduction of S. salivarius in air and water channels was obtained. No growth was observed in clinically used high-speed handpieces...

  16. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  17. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  18. Development of a mobile device optimized cross platform-compatible oral pathology and radiology spaced repetition system for dental education.

    Science.gov (United States)

    Al-Rawi, Wisam; Easterling, Lauren; Edwards, Paul C

    2015-04-01

    Combining active recall testing with spaced repetition increases memory retention. The aim of this study was to evaluate and compare students' perception and utilization of an electronic spaced repetition oral pathology-radiology system in dental hygiene education and predoctoral dental education. The study employed an open-source suite of applications to create electronic "flashcards" that can be individually adjusted for frequency of repetition, depending on a user's assessment of difficulty. Accessible across multiple platforms (iOS, Android, Linux, OSX, Windows) as well as via any web-based browser, this framework was used to develop an oral radiology-oral pathology database of case-based questions. This system was introduced in two courses: sophomore oral pathology for dental students and sophomore radiology for dental hygiene students. Students were provided free software and/or mobile tablet devices as well as a database of 300 electronic question cards. Study participants were surveyed on frequency and extent of use. Perception-based surveys were used to evaluate their attitudes towards this technology. Of the eligible students, 12 of 22 (54.5%) dental hygiene and 49 of 107 (45.8%) dental students responded to the surveys. Adoption rates and student feedback were compared between the two groups. Among the respondents, acceptance of this technology with respect to educational usefulness was similar for the dental and dental hygiene students (median=5 on a five-point scale; dental hygiene interquartile range (IQR)=0; dental IQR=1). Only a minority of the survey respondents (25% dental, 33% dental hygiene) took advantage of one of the main benefits of this technology: automated spaced repetition.

  19. A clinical protocol for predicting outcomes with an implantable prosthetic device (Baha) in patients with single-sided deafness.

    Science.gov (United States)

    Snapp, Hillary A; Fabry, David A; Telischi, Fred F; Arheart, Kristopher L; Angeli, Simon I

    2010-01-01

    The Baha implant is increasingly becoming a common form of treatment for individuals with single-sided deafness (SSD). However, evidence-based guidelines for determining candidacy in these patients are not yet established. The purpose of this study was to investigate the clinical utility of speech-in-noise testing as a part of the preoperative evaluation of the Baha device in patients with SSD. The study design was a prospective cohort of 24 English-speaking adults comparing preoperative results on speech-in-noise measures using the Baha Cordelle II headband stimulator to postoperative results using the patient's external Baha processor. Outcome measures included signal-to-noise ratio (SNR) loss as measured by the QuickSIN™ and scores of self-reported disability questionnaires. Wilcoxon signed-rank test resulted in no significant difference between the preoperative and postoperative methods for measuring benefit on listening in noise tasks. Passing Bablok regression analysis showed the preoperative and postoperative results to be statistically equivalent, which suggests that postoperative results can be predicted during preoperative testing. Wilcoxon signed-rank test showed significant improvements in self-reported disability postoperatively. The results support the use of speech-in-noise measures as an accurate predictor of overall benefit in patients with SSD prior to implantation. American Academy of Audiology.

  20. Evaluation of reliability and validity of three dental color-matching devices.

    Science.gov (United States)

    Tsiliagkou, Aikaterini; Diamantopoulou, Sofia; Papazoglou, Efstratios; Kakaboura, Afrodite

    2016-01-01

    To assess the repeatability and accuracy of three dental color-matching devices under standardized and freehand measurement conditions. Two shade guides (Vita Classical A1-D4, Vita; and Vita Toothguide 3D-Master, Vita), and three color-matching devices (Easyshade, Vita; SpectroShade, MHT Optic Research; and ShadeVision, X-Rite) were used. Five shade tabs were selected from the Vita Classical A1-D4 (A2, A3.5, B1, C4, D3), and five from the Vita Toothguide 3D-Master (1M1, 2R1.5, 3M2, 4L2.5, 5M3) shade guides. Each shade tab was recorded 15 continuous, repeated times with each device under two different measurement conditions (standardized, and freehand). Both qualitative (color shade) and quantitative (L, a, and b) color characteristics were recorded. The color difference (ΔE) of each recorded value with the known values of the shade tab was calculated. The repeatability of each device was evaluated by the coefficient of variance. The accuracy of each device was determined by comparing the recorded values with the known values of the reference shade tab (one sample t test; α = 0.05). The agreement between the recorded shade and the reference shade tab was calculated. The influence of the parameters (devices and conditions) on the parameter ΔE was investigated (two-way ANOVA). Comparison of the devices was performed with Bonferroni pairwise post-hoc analysis. Under standardized conditions, repeatability of all three devices was very good, except for ShadeVision with Vita Classical A1-D4. Accuracy ranged from good to fair, depending on the device and the shade guide. Under freehand conditions, repeatability and accuracy for Easyshade and ShadeVision were negatively influenced, but not for SpectroShade, regardless of the shade guide. Based on the total of the color parameters assessed per device, SpectroShade was the most reliable of the three color-matching devices studied.

  1. A newly developed removable dental device for fused 3-D MRI/Meg imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kuboki, Takuo [Okayama Univ. (Japan). Dental School; Clark, G T; Akhtari, M; Sutherling, W W

    1999-06-01

    Recently 3-D imaging techniques have been used to shed light on the role of abnormal brain functions in such conditions as nocturnal bruxism and orofacial pain. In order to achieve precise 3-D image fusion between magnetic resonance images (MRI) and magnetoencephalography (MEG) data, we developed a removable dental device which attaches rigidly to the teeth. Using this device, correlation of MEG and MRI data points was achieved by the co-registration of 3 or more fiducial points. Using a Polhemus 3-space digitizer the locations of the points were registered on MEG and then a small amount of high-water-content material was placed at each point for registering these same points on MRI. The mean reproducibility of interpoint distances, determined for 2 subjects, was between 0.59 and 0.82 mm. Using a Monte Carlo statistical analysis we determined that the accuracy of a posterior projection from the fiducial points to any point within the strata of the brain is {+-}3.3 mm. The value of this device is that it permits reasonably precise and repeatable co-registration of these points and yet it is easily removed and replaced by the patient. Obviously such a device could also be adapted for use in diagnosis and analysis of brain functions related with other various sensory and motor functions (e.g., taste, pain, clenching) in maxillofacial region using MRI and MEG. (author)

  2. A newly developed removable dental device for fused 3-D MRI/Meg imaging

    International Nuclear Information System (INIS)

    Kuboki, Takuo; Clark, G.T.; Akhtari, M.; Sutherling, W.W.

    1999-01-01

    Recently 3-D imaging techniques have been used to shed light on the role of abnormal brain functions in such conditions as nocturnal bruxism and orofacial pain. In order to achieve precise 3-D image fusion between magnetic resonance images (MRI) and magnetoencephalography (MEG) data, we developed a removable dental device which attaches rigidly to the teeth. Using this device, correlation of MEG and MRI data points was achieved by the co-registration of 3 or more fiducial points. Using a Polhemus 3-space digitizer the locations of the points were registered on MEG and then a small amount of high-water-content material was placed at each point for registering these same points on MRI. The mean reproducibility of interpoint distances, determined for 2 subjects, was between 0.59 and 0.82 mm. Using a Monte Carlo statistical analysis we determined that the accuracy of a posterior projection from the fiducial points to any point within the strata of the brain is ±3.3 mm. The value of this device is that it permits reasonably precise and repeatable co-registration of these points and yet it is easily removed and replaced by the patient. Obviously such a device could also be adapted for use in diagnosis and analysis of brain functions related with other various sensory and motor functions (e.g., taste, pain, clenching) in maxillofacial region using MRI and MEG. (author)

  3. Understanding dental CAD/CAM for restorations - dental milling machines from a mechanical engineering viewpoint. Part A: chairside milling machines.

    Science.gov (United States)

    Lebon, Nicolas; Tapie, Laurent; Duret, Francois; Attal, Jean-Pierre

    2016-01-01

    The dental milling machine is an important device in the dental CAD/CAM chain. Nowadays, dental numerical controlled (NC) milling machines are available for dental surgeries (chairside solution). This article provides a mechanical engineering approach to NC milling machines to help dentists understand the involvement of technology in digital dentistry practice. First, some technical concepts and definitions associated with NC milling machines are described from a mechanical engineering viewpoint. The technical and economic criteria of four chairside dental NC milling machines that are available on the market are then described. The technical criteria are focused on the capacities of the embedded technologies of these milling machines to mill both prosthetic materials and types of shape restorations. The economic criteria are focused on investment costs and interoperability with third-party software. The clinical relevance of the technology is assessed in terms of the accuracy and integrity of the restoration.

  4. Simultaneous functional and fixed appliance therapy for growth modification and dental alignment prior to prosthetic habilitation in hypohidrotic ectodermal dysplasia: a clinical report.

    Science.gov (United States)

    Suri, Sunjay; Carmichael, Robert P; Tompson, Bryan D

    2004-11-01

    This clinical report describes the simultaneous use of functional and fixed appliances to modify the pattern of dentofacial development and align teeth in preparation for prosthodontic habilitation of a growing child with hypohidrotic ectodermal dysplasia. The treatment objective was to create a more favorable starting point for the prosthodontic phase of habilitation by improving the sagittal and vertical skeletal relationships and facial esthetics. This was accomplished through growth modification with functional appliances conducted simultaneously with eruption of maxillary and mandibular molars, dental arch expansion, alignment, and space management using fixed orthodontic appliances. Orthodontic retention was accomplished by means of removable partial dentures. A second phase of orthodontics conducted closer to the age of skeletal maturation will aim at definitive tooth alignment in preparation for dental implant-supported restorations.

  5. In vitro performance of DIAGNOdent laser fluorescence device for dental calculus detection on human tooth root surfaces

    Directory of Open Access Journals (Sweden)

    Thomas E. Rams

    2017-10-01

    Conclusions: Excellent intra- and inter-examiner reproducibility of autofluorescence intensity measurements was obtained with the DIAGNOdent laser fluorescence device on human tooth roots. Calculus-positive root surfaces exhibited significantly greater DIAGNOdent laser autofluorescence than calculus-free tooth roots, even with the laser probe tip directed parallel to root surfaces. These findings provide further in vitro validation of the potential utility of a DIAGNOdent laser fluorescence device for identifying dental calculus on human tooth root surfaces.

  6. Responsiveness of the Prosthetic Esthetic Scale

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov

    2017-01-01

    Objectives The aim of the study was to evaluate the responsiveness of the Prosthetic Esthetic Index (PEI) in a population who received prosthetic replacements. Materials and methods Fifty-seven patients who received prosthetic replacement of at least one tooth by means of fixed or removable...... prosthesis were professionally esthetically evaluated using the PEI and the Dental Aesthetic Index (DAI) before and after treatment. The participants further evaluated their oral esthetics using the Oral Health Impact Profile Aesthetic (OHIP-Aes) and Orofacial Esthetic Index (OES). Responsiveness......-Aes and OES scores. The PEI was more consistent in responsiveness than the DAI. Conclusions The PEI shows sufficient responsiveness for use in longitudinal studies and for use as a follow-up measure in clinical practice. Clinical relevance The PEI can in a standardized manner monitor and document esthetic...

  7. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    Science.gov (United States)

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  8. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  9. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  10. Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

    Science.gov (United States)

    Ji, Xue-Yue; Fei, Chun-Nan; Zhang, Ying; Zhang, Wei; Liu, Jun; Dong, Jie

    2016-08-01

    Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment. © 2016 FDI World Dental Federation.

  11. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  12. Effect of the gonadal integrity and the gender on responses of bone crestal levels in dogs with two dental prosthetic abutment types

    Directory of Open Access Journals (Sweden)

    Gilberto Valenzuela Vásquez

    2015-01-01

    Full Text Available Catorce perros mestizos adultos (5 intactos y 9 esterilizados, compuestos por siete machos y siete hembras fueron utilizadas para evaluar el efecto de dos tipos de aditamentos protésicos de implantes dentales sobre el nivel de la cresta ósea alveolar. Los implantes dentales fueron colocados quirúrgicamente en zonas de cuartos premolares inferiores y restaurados con aditamentos protésicos convencionales (CONV y de cambio de plataforma (PFS. Ambos aditamentos protésicos fueron evaluados en cada perro. El estudio duró 180 días, en los que se realizó la restauración al día 60 post-quirúrgicamente colocados los implantes, la evaluación del nivel de la cresta ósea alveolar se realizó en los días 0, 30, 60 y 90 después de la restauración (corona cementada a través de medición indirecta utilizando un sensor radiográfico digital. Los datos experimentales se analizaron mediante un diseño completamente al azar, la unidad experimental fue el perro (efecto aleatorio, el tratamiento era el tipo de pilar protésico (efectos fijos, y el nivel de la cresta ósea de cada lado del implante (mesial y distal fue la observación. Además, factores como la condición gonadal (intactos y castrados y el género (masculino y femenino se incluyeron en el análisis estadístico para evaluar su papel en la magnitud de los cambios (interacciones en los niveles de cresta ósea alveolar. El promedio de pérdida de hueso crestal fue 0.400 ± 0.186 mm. En general, los perros con CONV tuvieron una mayor pérdida de la cresta ósea que los perros con PFS. En los perros intactos que recibieron PFS se observó una menor pérdida ósea, pero en perros castrados, el tipo de aditamento no tuvo efecto (P = 0,98 en el nivel de pérdida de la cresta ósea; por lo tanto, se detectó una interacción (P 0.77 entre el género y el tipo de aditamento, de manera similar, analizado como único factor de variación, el género no tuvo efecto (P = 0,26 en las respuestas del

  13. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  15. Slow-release fluoride devices for the control of dental decay.

    Science.gov (United States)

    Chong, Lee-Yee; Clarkson, Jan E; Dobbyn-Ross, Lorna; Bhakta, Smriti

    2018-03-01

    Slow-release fluoride devices have been investigated as a potentially cost-effective method of reducing dental caries in people with high risk of disease. This is the second update of the Cochrane Review first published in 2006 and previously updated in 2014. To evaluate the effectiveness and safety of different types of slow-release fluoride devices on preventing, arresting, or reversing the progression of carious lesions on all surface types of primary (deciduous) and permanent teeth. Cochrane Oral Health's Information Specialist searched the following electronic databases: Cochrane Oral Health's Trials Register (to 23 January 2018); the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 12) in the Cochrane Library (searched 23 January 2018); MEDLINE Ovid (1946 to 23 January 2018); and Embase Ovid (1980 to 23 January 2018). The US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials (23 January 2018). We placed no restrictions on the language or date of publication when searching the electronic databases. Parallel randomised controlled trials (RCTs) comparing slow-release fluoride devices with an alternative fluoride treatment, placebo, or no intervention in all age groups. The main outcome measures sought were changes in numbers of decayed, missing, and filled teeth or surfaces (DMFT/DMFS in permanent teeth or dmft/dmfs in primary teeth), and progression of carious lesions through enamel and into dentine. We conducted data collection and analysis using standard Cochrane review methods. At least two review authors independently performed all the key steps in the review such as screening of abstracts, application of inclusion criteria, data extraction, and risk of bias assessment. We resolved discrepancies through discussions or arbitration by a third or fourth review author. We found no evidence comparing slow

  16. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Review Resources AT Education Blind Rehab Chiropractic Service Polytrauma/TBI Prosthetics & Sensory Aids Recreation Therapy More Health ... Military Sexual Trauma PTSD Research (MIRECC) Military Exposures Polytrauma Rehabilitation Spinal Cord Injury Telehealth Womens Health Issues ...

  17. Prosthetics / Limb Loss

    Science.gov (United States)

    ... implant to encourage the sealing process. Implanting titanium prosthetic components avoids the need for a socket. But preventing bacterial invasion and infection is a key challenge, one that this research ...

  18. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  19. Prosthetic considerations for orthodontic implant site development in the adult patient.

    Science.gov (United States)

    Holst, Alexandra I; Nkenke, Emeka; Blatz, Markus B; Geiselhöringer, Hans; Holst, Stefan

    2009-11-01

    Proper site development is a key factor for long-term clinical success of dental implants. Whereas surgical and restorative techniques have been refined to ensure predictable functional and esthetic outcome, individual clinical prerequisites do not always allow proper placement of implants when prosthetic and material properties are considered. Orthodontic tooth movement may be a viable and nonsurgical site development treatment option. With the introduction and advancements of minimal invasive and less visible orthodontic appliances, a growing number of adult patients are willing to obtain orthodontic treatment. The spectrum of modern appliances is broad and ranges from clear aligners to lingual brackets. Skeletal anchorage devices such as orthodontic mini-implants often eliminate unpopular external anchorage devices (ie, headgear) in adult patients, This article discusses the selection of an appropriate pretreatment approach by taking patient-specific criteria into account.

  20. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  1. Pre prosthetic reconstruction of alveolar ridge

    Directory of Open Access Journals (Sweden)

    Prabhuji Munivenkatappa Lakshmaiahenkatesh

    2011-01-01

    Full Text Available Dento-alveolar bony defects are common and occur due to a variety of causes, such as, pulpal pathology, traumatic tooth extraction, advanced periodontal disease, implant failure, tumor or congenital anomalies. These defects often cause a significant problem in dental treatment and rehabilitation. Many techniques exist for effective soft and hard tissue augmentation. The approach is largely based on the extent of the defect and specific procedures to be performed for the implant or prosthetic rehabilitation. This article presents case reports of soft and hard tissue ridge augmentation.

  2. [Multiple agenesis and prosthetic restoration].

    Science.gov (United States)

    Renault, P

    1990-03-01

    Cases of multiple agenesia present some difficulties in the treatment planing. Three situations may be encountered: limited agenesia, restored by a fixed, bonded or cemented prosthesis, multiple uni- or bimaxillary agenesia without remaining of deciduous teeth, restored by a fixed, bonded or cemented prosthesis or the partial adjacent prosthesis, multiple uni- or bimaxillary agenesia with remaining of deciduous teeth, restored by means of a supra-dental prosthesis. The first two situations have been described in dental literature and are relatively easy to treat. The same is not true for the third situation, where the decision to keep the temporary teeth considerably increases the difficulty of prosthetic restoration. This subject will be illustrated by the presentation of a clinical case of multiple bi-maxillary agenesia. The patient has: on the maxilla: an absence of 9 permanent teeth (18, 15, 14, 12, 22, 23, 24, 25, 28) and the presence of 4 deciduous teeth (62, 63, 64, 65), on the mandible: an absence of all permanent teeth, with the exception of 36 and 46, and the remaining of 4 deciduous teeth (75, 73, 83, 84). The remaining of deciduous teeth and the presence of a very high inter-arch space led to opting for dental coverage so as to keep the deciduous teeth and a proper vertical dimension. The patient wished to solve his "problem" in the maxilla first, and is not wanting to undergo the extraction of his deciduous teeth. The following therapeutic proposal was adapted: On the maxilla, a three-step procedure: first step: building of metal copings on 13, 16 and 26 and metal-ceramic crowns on 11 and 21, second step: building of telescop crowns on 16 and 26 and clasps on 13, 11 and 21, third step: casting of the removable partial denture framework and soldering to the telescop crowns and clasps. On the mandible, a provisional restoration using a supra-dental resin removable partial denture with ceramic occlusal surfaces was adopted. The aesthetic and functional

  3. Orthodontic Space Closure Versus Prosthetic Replacement of Missing Upper Lateral Incisors in Patients With Bilateral Cleft Lip and Palate

    NARCIS (Netherlands)

    Oosterkamp, Barbara C. M.; Dijkstra, Pieter U.; Remmelink, Hendrik J.; van Oort, Robert P.; Sandham, John

    2010-01-01

    Objective To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate The predominant mode of prosthetic replacement was resin-bonded bridges Patients and Methods The retrospective

  4. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  5. Amputation and Prosthetics

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Amputation and Prosthetics Email to a friend * required ...

  6. New techniques in dental surgical CT

    International Nuclear Information System (INIS)

    Rabin, D.N.; Rabin, H.; Sakowicz, B.A.; Rabin, M.A.; Rabin, S.I.; Schwartz, A.

    1991-01-01

    This paper demonstrates how CT can be used with dental software to evaluate prosthetic failure and for planning dental implants when a stent is used. The Food and Drug Administration issued a safety alert for proplast-coated temporomandibular joint prostheses. Prosthetic failure occurs with migration, fragmentation, or bone erosion. Sagittal CT requiring a special head holder can instead be performed with reformatted sagittal images. The technique of dental implant CT changes when a dental stent is used to provide more accurate implant anchorage and planning. Images must be parallel to the occlusal plane. We will demonstrate these techniques and present their rationale

  7. The Prosthetic Workflow in the Digital Era

    Directory of Open Access Journals (Sweden)

    Lidia Tordiglione

    2016-01-01

    Full Text Available The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010 software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  8. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  9. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  10. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  11. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials.

    Science.gov (United States)

    Vallittu, Pekka K

    2018-01-01

    Fibr-reinforced composites (FRC) have been used successfully for decades in many fields of science and engineering applications. Benefits of FRCs relate to physical properties of FRCs and versatile production methods, which can be utilized. Conventional hand lamination of prefabricated FRC prepregs is utilized still most commonly in fabrication of dental FRC devices but CAD-CAM systems are to be come for use in certain production steps of dental constructions and medical FRC implants. Although metals, ceramics and particulate filler resin composites have successfully been used as dental and medical biomaterials for decades, devices made out of these materials do not meet all clinical requirements. Only little attention has been paid to FRCs as dental materials and majority of the research in dental field has been focusing on particulate filler resin composites and in medical biomaterial research to biodegradable polymers. This is paradoxical because FRCs can potentially resolve many of the problems related to traditional isotropic dental and medical materials. This overview reviews the rationale and status of using biostable glass FRC in applications from restorative and prosthetic dentistry to cranial surgery. The overview highlights also the critical material based factors and clinical requirement for the succesfull use of FRCs in dental reconstructions.

  12. In vitro performance of DIAGNOdent laser fluorescence device for dental calculus detection on human tooth root surfaces.

    Science.gov (United States)

    Rams, Thomas E; Alwaqyan, Abdulaziz Y

    2017-10-01

    This study assessed the reproducibility of a red diode laser device, and its capability to detect dental calculus in vitro on human tooth root surfaces. On each of 50 extracted teeth, a calculus-positive and calculus-free root surface was evaluated by two independent examiners with a low-power indium gallium arsenide phosphide diode laser (DIAGNOdent) fitted with a periodontal probe-like sapphire tip and emitting visible red light at 655 nm wavelength. Laser autofluorescence intensity readings of examined root surfaces were scored on a 0-99 scale, with duplicate assessments performed using the laser probe tip directed both perpendicular and parallel to evaluated tooth root surfaces. Pearson correlation coefficients of untransformed measurements, and kappa analysis of data dichotomized with a >40 autofluorescence intensity threshold, were calculated to assess intra- and inter-examiner reproducibility of the laser device. Mean autofluorescence intensity scores of calculus-positive and calculus-free root surfaces were evaluated with the Student's t -test. Excellent intra- and inter-examiner reproducibility was found for DIAGNOdent laser autofluorescence intensity measurements, with Pearson correlation coefficients above 94%, and kappa values ranging between 0.96 and 1.0, for duplicate readings taken with both laser probe tip orientations. Significantly higher autofluorescence intensity values were measured when the laser probe tip was directed perpendicular, rather than parallel, to tooth root surfaces. However, calculus-positive roots, particularly with calculus in markedly-raised ledges, yielded significantly greater mean DIAGNOdent laser autofluorescence intensity scores than calculus-free surfaces, regardless of probe tip orientation. DIAGNOdent autofluorescence intensity values >40 exhibited a stronger association with calculus (36.6 odds ratio) then measurements of ≥5 (20.1 odds ratio) when the laser probe tip was advanced parallel to root surfaces. Excellent

  13. Prosthetic rehabilitation for a patient with microstomia: a case report

    Directory of Open Access Journals (Sweden)

    Moslehifard E

    2011-04-01

    Full Text Available "nFabrication of dental prosthesis for patients with microstomia has long been a problem for dentists. Microstomia is defined as an abnormally small oral orifice. Prosthetic rehabilitation of microstomia patients presents difficulties at all stages, from the preliminary impressions to fabrication of prosthesis. This study described a method for making impressions for patients with limited opening of the oral cavity which the use of a full-size impression tray was not possible.

  14. The perils of dental vacation: possible anaesthetic and medicolegal consequences.

    Science.gov (United States)

    Feltracco, Paolo; Gaudio, Rosa Maria; Barbieri, Stefania; Tiano, Letizia; Iacobone, Maurizio; Viel, Giovanni; Tonetti, Tommaso; Galligioni, Helmut; Bortolato, Andrea; Ori, Carlo; Avato, Francesco Maria

    2013-01-01

    The aim of this paper is to emphasize anaesthesiologists' difficulty in detecting poor dentition in cases of poorly applied prostheses and/or advanced periodontal disease, and to establish whether it is possible, and in which conditions, to calculate compensation in cases of dental damage postlaryngoscopy and/or intubation. The main complex problem here lies in trying to reconstruct exactly what the dental situation was before the teeth were damaged. For this reason the important preoperative factors (dental prostheses, crown fractures, parodontal disease, etc.) must be clearly shown before surgery on a dental chart. Two cases of interest, both to anaesthesiologists practising intubation and medicolegal physicians who have to deal with potential claims, are briefly reported. The first patient was a 55-year-old diabetic patient, who underwent emergency surgery for acute abdominal pathology. He had gone outside Italy for dental treatment three years previously and now presented with very poor pre-existing dentition, carefully noted on an anaesthetic chart. He now demanded compensation for dental damage due to intubation in Italy; the resulting dental treatment was very expensive because substantial remedial work was required. The second patient had received treatment outside Italy, work which involved cosmetic coating of the teeth. After surgery in Italy, she demanded compensation because one tooth, which had been coated and appeared to be healthy, was broken after emergency intubation. In both cases, the patients demanded very high compensation. Dental tourism alone accounts for more than 250,000 patients each year who combine a holiday with dental treatment in Eastern Europe. However, if prosthetic devices or conservative treatments are not applied correctly, it should be noted that durability may be poorer than expected, but iatrogenic damage may also be caused.

  15. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Amjad Alwaal

    2017-01-01

    Conclusions: There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  16. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  17. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  18. Specialty choice among dental students in Ibadan, Nigeria ...

    African Journals Online (AJOL)

    The majority of dental students at the University of Ibadan preferred the oral and maxillofacial surgery (OMS) specialty above all other dental specialties, while prosthetic dentistry was least preferred. Of all the factors to take into consideration when choosing a dental specialty, personal interest was the only factor considered ...

  19. 21 CFR 872.4130 - Intraoral dental drill.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral dental drill. 872.4130 Section 872.4130...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4130 Intraoral dental drill. (a) Identification. An intraoral dental drill is a rotary device intended to be attached to a dental handpiece to drill holes in...

  20. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  1. Biocompatibility of dental alloys

    Energy Technology Data Exchange (ETDEWEB)

    Braemer, W. [Heraeus Kulzer GmbH and Co. KG, Hanau (Germany)

    2001-10-01

    Modern dental alloys have been used for 50 years to produce prosthetic dental restorations. Generally, the crowns and frames of a prosthesis are prepared in dental alloys, and then veneered by feldspar ceramics or composites. In use, the alloys are exposed to the corrosive influence of saliva and bacteria. Metallic dental materials can be classified as precious and non-precious alloys. Precious alloys consist of gold, platinum, and small amounts of non-precious components such as copper, tin, or zinc. The non-precious alloys are based on either nickel or cobalt, alloyed with chrome, molybdenum, manganese, etc. Titanium is used as Grade 2 quality for dental purposes. As well as the dental casting alloys, high purity electroplated gold (99.8 wt.-%) is used in dental technology. This review discusses the corrosion behavior of metallic dental materials with saliva in ''in vitro'' tests and the influence of alloy components on bacteria (Lactobacillus casei and Streptococcus mutans). The test results show that alloys with high gold content, cobalt-based alloys, titanium, and electroplated gold are suitable for use as dental materials. (orig.)

  2. Orthodontic space closure versus prosthetic replacement of missing upper lateral incisors in patients with bilateral cleft lip and palate.

    Science.gov (United States)

    Oosterkamp, Barbara C M; Dijkstra, Pieter U; Remmelink, Hendrik J; van Oort, Robert P; Sandham, Andrew

    2010-11-01

    To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate. The predominant mode of prosthetic replacement was resin-bonded bridges. The retrospective study group consisted of 17 patients treated with orthodontic space closure (13 men, four women; median age, 27.1 years; interquartile range, 20.6 to 33.3 years) and 10 patients treated with prosthetic replacement (five men, five women; median age, 27.7 years; interquartile range, 20.9 to 39.7 years). Dental aesthetics were evaluated by the patients and by a professional panel. Mandibular function was evaluated by means of the mandibular function impairment questionnaire. The level of mandibular impairment was calculated using the Function Impairment Rating Scale. With respect to dental aesthetics, no significant differences between patients treated with orthodontic space closure and prosthetic replacement were found. With respect to function, the level of mandibular impairment was significantly higher in patients treated with prosthetic replacement compared with patients treated with orthodontic space closure, as indicated by high scores on specific masticatory functions. Orthodontic space closure and prosthetic replacement in bilateral cleft lip and palate patients produce similar results in terms of aesthetics. In terms of function, prosthetic replacement results in significantly more impairment of specific masticatory functions.

  3. Quality improvement program reduces perioperative dental injuries - A review of 64,718 anesthetic patients.

    Science.gov (United States)

    Kuo, Yi-Wei; Lu, I-Cheng; Yang, Hui-Ying; Chiu, Shun-Li; Hsu, Hung-Te; Cheng, Kuang-I

    2016-12-01

    Perioperative dental injury (PDI) is a common adverse event associated with anesthesia that can easily lead to medicolegal litigation. A quality improvement program was conducted with the electronic, standardized dental chart to document dentition before anesthesia and dentist consultation when necessary. This study aimed to reduce PDIs through execution of a quality improvement program. We reviewed the 42-month interval anesthetic records of 64,718 patients who underwent anesthesia. A standardized electronic dental chart was designed to identify any dental prosthetics, fixed and removable dentures, and degree of loose teeth. The incidence of dental injuries associated with anesthesia was separated into three time periods: baseline, initiative (Phase I), and execution (Phase II). Primary outcome measurement was the incidence of PDIs related to anesthesia. The overall incidence of dental injury related to anesthesia was 0.059% (38/64,718 patients). During the baseline period, the dental injury rate was 0.108% (26/24,137 patients), and it decreased from 0.051% in the initiative period (10/19,711 patients) to 0.009% in the execution period (2/20,870 patients) during implementation of the quality improvement program. Most dental injuries were associated with laryngeal mask airway (42.1%) and laryngoscopy (28.9%). The most commonly involved teeth were the upper incisors. Dental injury incidence was significantly reduced and remained at low levels after implementation of the quality improvement program. We suggest the implementation of a standardized dental examination into the preoperative evaluation system adding pathologic teeth fixed or protected devices to minimize dental injury associated with anesthesia. Copyright © 2016. Published by Elsevier Taiwan LLC.

  4. 21 CFR 872.6390 - Dental floss.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental floss. 872.6390 Section 872.6390 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6390 Dental floss. (a) Identification. Dental floss is a...

  5. Use of SIG device to accurately place permanent miniature dental implants to retain mandibular overdenture. A case report.

    Science.gov (United States)

    Sussman, Harold I; Goodridge, Opal F

    2006-01-01

    A case of mini-dental implant insertion for retention of a mandibular overdenture in a hospitalized patient has been documented. The additional use of the SIG (drill guide) directional device in the implant placement protocol gave the practitioner more confidence and resulted in the proper alignment of the three ball-top, one-piece fixtures. The three implants were inserted exactly 1 cm apart and parallel to each other. The distal fixtures were approximately 1 cm away from the mental foramina, thereby eliminating the risk of lip paresthesia. Keeper caps were placed in the denture's intaglio after one month. The keeper caps allowed for proper retention of the overdenture. The caps also enabled the patient to easily insert and withdraw his denture, even though he displayed limited manual dexterity. The tissue response was excellent, and oral hygiene was made easier with adequate spacing of the exposed ball-tops. The overall experience for both the operator and the patient was very positive. General dentists should be able to readily master this technique and add it to their armamentarium for the benefit of all their patients.

  6. Comprehensive dental management in a Hallermann–Streiff ...

    African Journals Online (AJOL)

    2014-09-24

    Sep 24, 2014 ... During the follow‑up period, rapidly progressive root resorption was ... progressive root resorption was detected in the primary maxillary anterior ... dental literature shows that orthodontic/orthognathic, surgical, prosthetic ...

  7. Assessment of the diagnostic accuracy of {sup 18}F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); Delgado-Bolton, Roberto C. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, La Rioja (Spain); Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen [Clinico San Carlos University Hospital, Department of Cardiology, Madrid (Spain); Ferrer, Manuel E.F. [Clinico San Carlos University Hospital, Research Unit, Madrid (Spain)

    2016-12-15

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of {sup 18}F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent {sup 18}F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. {sup 18}F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of {sup 18}F-FDG PET/CT in the diagnosis of suspected IE of PVs

  8. Assessment of the diagnostic accuracy of "1"8F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    International Nuclear Information System (INIS)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L.; Delgado-Bolton, Roberto C.; Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen; Ferrer, Manuel E.F.

    2016-01-01

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of "1"8F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent "1"8F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. "1"8F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of "1"8F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is

  9. In Vivo and in Vitro Evaluations of Repeatability and Accuracy of VITA Easyshade® Advance 4.0 Dental Shade-Matching Device

    Directory of Open Access Journals (Sweden)

    Davor Illeš

    2015-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the intra-device repeatability and accuracy of dental shade-matching device (VITA Easyshade® Advance 4.0 using both in vitro and in vivo models. Materials and methods: For the repeatability assessment, the in vivo model utilized shade-matching device to measure the central region of the labial surface of right maxillary central incisors of 10 people twice. The following tooth colors were measured: B1, A1, A2, A3, C1 and C3. The in vitro model included the same six Vitapan Classical tabs. Two measurements were made of the central region of each shade tab. For the accuracy assessment, each shade tab from 3 Vitapan Classical shade guides was measured once. CIE L*a*b* values were determined. Intraclass correlation coefficients (ICCs were used to analyze the in vitro and in vivo intra-device repeatability of the shade-matching device. The difference between in vitro and in vivo models was analyzed. Accuracy of the device tested was calculated. Results: The mean color differences for in vivo and in vitro models were 3.51 and 1.25 E units, respectively. The device repeatability ICCs for in vivo measurements ranged from 0.858 to 0.971 and for in vitro from 0.992 to 0.994. Accuracy of the device tested was 93.75%. Conclusion: Within the limitations of the experiment, VITA Easyshade®Advance 4.0 dental shade-matching device enabled reliable and accurate measurement. It can be a valuable tool for the determination of tooth colours.

  10. Dental lesions and restorative treatment in molars

    Directory of Open Access Journals (Sweden)

    Gheorghiu Irina-Maria

    2017-08-01

    Full Text Available This article review specific clinical issues of the molar teeth, as well as the therapeutic approach of their pathology. The dental pathology we face in the group of molars is related to: dental caries, dental trauma (crown and crown-root fractures, dental wear phenomena. The therapeutic approach of the molar teeth is represented by: restoration of the loss of hard dental tissues; endodontic treatments of pulpal and periapical complications; surgical treatment. The restorative treatments in molars are: direct restorations, with or without supplementary anchorage for obturations; inlay, onlay; prosthetic crown.

  11. ARM-based visual processing system for prosthetic vision.

    Science.gov (United States)

    Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J

    2011-01-01

    A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.

  12. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Advanced Prosthetic Gait Training Tool

    Science.gov (United States)

    2015-12-01

    modules to train individuals to distinguish gait deviations (trunk motion and lower-limb motion). Each of these modules help trainers improve their...AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool PRINCIPAL INVESTIGATOR: Dr. Karim Abdel-Malek CONTRACTING...study is to produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities

  14. Orientation of handle for successful prosthetic treatment in patients with an anatomic compromise after a maxillectomy.

    Science.gov (United States)

    Sumita, Yuka I; Hattori, Mariko; Elbashti, Mahmoud E; Taniguchi, Hisashi

    2017-05-01

    This clinical technique provides a key procedure for successful prosthetic treatment in patients with an anatomical compromise after a maxillectomy. When making a preliminary impression, the clinician must keep the handle of the stock tray parallel to the patient's interpupillary line extraorally to maintain the correct position of the tray and to make a record of the inclination of the occlusal plane. This simple consideration during this first step of making a preliminary impression can be an important guide for both dentists and dental technicians. Information about the correct positioning of the tray and the inclination of the occlusal plane obtained by using a stock tray handle will greatly reduce the stress experienced by dentists, dental technicians, and patients during the fabrication of the prosthesis and will ultimately lead to successful prosthetic treatment in patients with anatomic compromise resulting from a maxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  16. Nitinol for Prosthetic and Orthotic Applications

    Science.gov (United States)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  17. Can we close large prosthetic space with orthodontics?

    Science.gov (United States)

    Mesko, Mauro Elias; Skupien, Jovito Adiel; Valentini, Fernanda; Pereira-Cenci, Tatiana

    2013-01-01

    For years, the treatment for the replacement of a missing tooth was a fixed dental prosthesis. Currently, implants are indicated to replace missing teeth due to high clinical success and with the advantage of not performing preparations in the adjacent tooth. Another option for space closure is the use of orthodontics associated to miniscrews for anchorage allowing better control of the orthodontic biomechanics and especially making possible closure of larger prosthetic spaces. Thus, this article describes two cases with indications and discussion of the advantages and disadvantages of using orthodontics for prosthetic spaces closure. The cases herein presented show that it is possible to close an space when there are available teeth in the adjacent area. It can be concluded that when a malocclusion is present there will be a strong trend to indicate space closure by orthodontic movement as it preserves natural teeth and seems a more physiological approach.

  18. Surgical templates for dental implant positioning; current knowledge and clinical perspectives

    Directory of Open Access Journals (Sweden)

    Mohammed Zaheer Kola

    2015-01-01

    Full Text Available Dental implants have been used in a variety of different forms for many years. Since the mid-20 th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark was one of the initial pioneers who applied scientifically based research techniques to develop an endosseous implant that forms an immobile connection with bone. The need for a dental implant to completely address multiple physical and biological factors imposes tremendous constraints on the surgical and handling protocol. Metallic dental implants have been successfully used for decades, but they have serious shortcomings related to their bony union and the fact that their mechanical properties do not match those of bone. However, anatomic limitation and restorative demands encourage the surgeon to gain precision in planning and surgical positioning of dental implants. Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is advisable to establish a logical continuity between the planned restoration and the surgical phases, it is essential to use a transfer device that for sure increases the predictability of success. The surgical guide template is fabricated by a dental technician after the presurgical restorative appointments that primarily include determination of occlusal scheme and implant angulations. Here, authors genuinely attempted to review the evolution and clinical applicability of surgical templates used in the placement of dental implants.

  19. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  20. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  1. 21 CFR 872.4630 - Dental operating light.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operating light. 872.4630 Section 872.4630...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4630 Dental operating light. (a) Identification. A dental operating light, including the surgical headlight, is an AC-powered device intended to illuminate...

  2. 21 CFR 872.4620 - Fiber optic dental light.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiber optic dental light. 872.4620 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4620 Fiber optic dental light. (a) Identification. A fiber optic dental light is a device that is a light, usually AC-powered, that consists of glass or...

  3. 21 CFR 872.6890 - Intraoral dental wax.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral dental wax. 872.6890 Section 872.6890...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6890 Intraoral dental wax. (a) Identification. Intraoral dental wax is a device made of wax intended to construct patterns from which custom made metal...

  4. Novel Osteogenic Ti-6Al-4V Device For Restoration Of Dental Function In Patients With Large Bone Deficiencies: Design, Development And Implementation.

    Science.gov (United States)

    Cohen, D J; Cheng, A; Kahn, A; Aviram, M; Whitehead, A J; Hyzy, S L; Clohessy, R M; Boyan, B D; Schwartz, Z

    2016-02-08

    Custom devices supporting bone regeneration and implant placement are needed for edentulous patients with large mandibular deficiencies where endosteal implantation is not possible. We developed a novel subperiosteal titanium-aluminum-vanadium bone onlay device produced by additive manufacturing (AM) and post-fabrication osteogenic micro-/nano-scale surface texture modification. Human osteoblasts produced osteogenic and angiogenic factors when grown on laser-sintered nano-/micro-textured surfaces compared to smooth surfaces. Surface-processed constructs caused higher bone-to-implant contact, vertical bone growth into disk pores (microCT and histomorphometry), and mechanical pull-out force at 5 and 10 w on rat calvaria compared to non surface-modified constructs, even when pre-treating the bone to stimulate osteogenesis. Surface-modified wrap-implants placed around rabbit tibias osseointegrated by 6 w. Finally, patient-specific constructs designed to support dental implants produced via AM and surface-processing were implanted on edentulous mandibular bone. 3 and 8 month post-operative images showed new bone formation and osseointegration of the device and indicated stability of the dental implants.

  5. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  6. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  7. The Role of Virtual Articulator in Prosthetic and Restorative Dentistry

    Science.gov (United States)

    Aljanakh, Mohammad

    2014-01-01

    Virtual reality is a computer based technology linked with the future of dentistry and dental practice. The virtual articulator is one such application in prosthetic and restorative dentistry based on virtual reality that will significantly reduce the limitations of the mechanical articulator, and by simulation of real patient data, allow analyses with regard to static and dynamic occlusion as well as to jaw relation. It is the purpose of this article to present the concepts and strategies for a future replacement of the mechanical articulator by a virtual one. Also, a brief note on virtual reality haptic system has been highlighted along with newly developed touch enabled virtual articulator. PMID:25177664

  8. Is the Prosthetic Homologue Necessary for Embodiment?

    Science.gov (United States)

    Dornfeld, Chelsea; Swanston, Michelle; Cassella, Joseph; Beasley, Casey; Green, Jacob; Moshayev, Yonatan; Wininger, Michael

    2016-01-01

    Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of five hands, and whether the hand selection (regardless of homology) is consistent across multiple exposures to the same (but reordered) set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures). Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation.

  9. Prosthetic management of deciduous teeth

    OpenAIRE

    Bassil, Jean

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária Introduction: Situations of single or multiple edentulous are not an exception during childhood. Prosthetic management is necessary in case of absence of replacing tooth or when its eruption is planned too far in time. Indications of prosthetic rehabilitation for children are multiple and rise from the etiologic factors caus...

  10. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    Science.gov (United States)

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  11. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report

    Directory of Open Access Journals (Sweden)

    R. Somayaji

    2016-11-01

    Full Text Available Abstract Background Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. Case presentation A case of chronic hip prosthetic joint infection (PJI caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. Conclusions We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  12. Myoelectric control of prosthetic hands: state-of-the-art review

    Directory of Open Access Journals (Sweden)

    Geethanjali P

    2016-07-01

    Full Text Available Purushothaman Geethanjali School of Electrical Engineering Department of Control and Automation VIT University, Vellore, Tamil Nadu, India Abstract: Myoelectric signals (MES have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. Keywords: EMG, assistive device, amputee, myoelectric control, electric powered, body ­powered, bioelectric signal control

  13. [Virtual Planning of Prosthetic Treatment of the Orbit].

    Science.gov (United States)

    Veit, Johannes A; Thierauf, Julia; Egner, Kornelius; Wiggenhauser, Paul Severin; Friedrich, Daniel; Greve, Jens; Schuler, Patrick J; Hoffmann, Thomas K; Schramm, Alexander

    2017-06-01

    Optimal positioning of bone-anchored implants in the treatment of patients with orbital prosthesis is challenging. The definition of implant axis as well as the positioning of the implants is important to prevent failures in prosthetic rehabilitation in these patients. We performed virtual planning of enossal implants at a base of a standard fan beam CT scan using the software CoDiagnostiX™ (DentalWings, Montréal, Canada). By 3D-printing a surgical guide for drilling and implant insertion was manufactured (Med-610™, Stratasys, Rehovot, Israel). An orbital exenteration was performed in a patient after shrinkage of the eyelids 20 years after enucleation and radiation of the orbit due to rhabdomyosarcoma. 4 Vistafix-3 implants (Cochlear™, Cochlea, Centennial, USA) were primarily inserted after resection with the help of the 3D-surgical guide. Prosthetic rehabilitation could be achieved as preplanned to a predictable result. The individual prosthesis of the orbit showed good functional and esthetic outcome. The virtual 3D-planning of endosseous implants for prosthetic orbital and periorbital reconstruction is easy to use and facilitates optimal placement of implants especially in posttherapeutically altered anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Self-cleaning skin-like prosthetic polymer surfaces

    Science.gov (United States)

    Simpson, John T [Clinton, TN; Ivanov, Ilia N [Knoxville, TN; Shibata, Jason [Manhattan Beach, CA

    2012-03-27

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  15. Consumer design priorities for upper limb prosthetics.

    Science.gov (United States)

    Biddiss, Elaine; Beaton, Dorcas; Chau, Tom

    2007-11-01

    To measure consumer satisfaction with upper limb prosthetics and provide an enumerated list of design priorities for future developments. A self-administered, anonymous survey collected information on participant demographics, history of and goals for prosthesis use, satisfaction, and design priorities. The questionnaire was available online and in paper format and was distributed through healthcare providers, community support groups, and one prosthesis manufacturer; 242 participants of all ages and levels of upper limb absence completed the survey. Rates of rejection for myoelectric hands, passive hands, and body-powered hooks were 39%, 53%, and 50%, respectively. Prosthesis wearers were generally satisfied with their devices while prosthesis rejecters were dissatisfied. Reduced prosthesis weight emerged as the highest priority design concern of consumers. Lower cost ranked within the top five design priorities for adult wearers of all device types. Life-like appearance is a priority for passive/cosmetic prostheses, while improved harness comfort, wrist movement, grip control and strength are required for body-powered devices. Glove durability, lack of sensory feedback, and poor dexterity were also identified as design priorities for electric devices. Design priorities reflect consumer goals for prosthesis use and vary depending on the type of prosthesis used and age. Future design efforts should focus on the development of more light-weight, comfortable prostheses.

  16. Sensory feedback in upper limb prosthetics.

    Science.gov (United States)

    Antfolk, Christian; D'Alonzo, Marco; Rosén, Birgitta; Lundborg, Göran; Sebelius, Fredrik; Cipriani, Christian

    2013-01-01

    One of the challenges facing prosthetic designers and engineers is to restore the missing sensory function inherit to hand amputation. Several different techniques can be employed to provide amputees with sensory feedback: sensory substitution methods where the recorded stimulus is not only transferred to the amputee, but also translated to a different modality (modality-matched feedback), which transfers the stimulus without translation and direct neural stimulation, which interacts directly with peripheral afferent nerves. This paper presents an overview of the principal works and devices employed to provide upper limb amputees with sensory feedback. The focus is on sensory substitution and modality matched feedback; the principal features, advantages and disadvantages of the different methods are presented.

  17. Neural-Network Control Of Prosthetic And Robotic Hands

    Science.gov (United States)

    Buckley, Theresa M.

    1991-01-01

    Electronic neural networks proposed for use in controlling robotic and prosthetic hands and exoskeletal or glovelike electromechanical devices aiding intact but nonfunctional hands. Specific to patient, who activates grasping motion by voice command, by mechanical switch, or by myoelectric impulse. Patient retains higher-level control, while lower-level control provided by neural network analogous to that of miniature brain. During training, patient teaches miniature brain to perform specialized, anthropomorphic movements unique to himself or herself.

  18. 21 CFR 872.4565 - Dental hand instrument.

    Science.gov (United States)

    2010-04-01

    ... chisel, endodontic broach, dental wax carver, endodontic pulp canal file, hand instrument for calculus... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A...

  19. CRITERIA FOR THE EVALUATION AND ESTIMATION OF IATROGENIC PROSTHETIC FACTORS – SEMIOLOGY AND SYMPTOMATOLOGY

    Directory of Open Access Journals (Sweden)

    G. LUCA

    2013-12-01

    Full Text Available Introduction: The principles lying at the basis of a balanced dental occlusion cannot be analyzed separately, but only if considering the teeth (and, implicitly, dental occlusion as integrated into the masticatory system, which includes the masticatory muscles, the temporo-mandibu‑ lary joint and the maxillary bones. Scope: The scope of the present study was to correlate and establish the interde‑ pendence between the morpholgically-incorrect prosthetic works and the tissular and functional damages suffered by the neighbouring structures, as a result of some incor‑ rectly-made prosthetic works. Also, the study aims at iden‑ tifying the factors and limits responsible for a prolongued maintenance of such irreversible pathological modificati‑ ons within an asymptomatic zone for the patient. Materials and method: The working hypothesis of the present inves‑ tigation started from the analysis of the various objective signs, versus the morphology of the incorrectly performed prosthetic works. The study, initiated as early as 2009, in a private stomatological clinics (DentEstet, Bucuresti, includes a number of 500 patients (250 women and 250 men, selected among the patients having addressed the stomatological office from various reasons (not always related to the prosthetic pathology of the cases here under investigation. Included in the study have been only the patients with fixed prosthetic works associated with one or several of the previously described objective signs, potentially induced by the iatrogeneicity of the prosthetic works. Results: The pathological effects of the iatrogenic works here under analysis, upon both the antagonistic and prosthetic support teeth, may be clinically identified during a minute examination performed prior to produ‑ cing irreversible final effects (abrasions, fractures, dental mobility, etc.. Such noxious effects of the iatrogenic pros‑ thetic works appear as a false masticatory comfort and as a

  20. Dental implants: A boon to dentistry

    Directory of Open Access Journals (Sweden)

    B H Sripathi Rao

    2015-01-01

    Full Text Available The development and use of implants is one of the biggest advances in dentistry in the last few decades. It has helped to give many solutions to tooth loss as well as maxillo facial prosthetics. This article traces the history and evolution of dental implants.

  1. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  2. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    Science.gov (United States)

    2012-12-21

    suspension system, socket- ankle /knee interface, etc.) associated with a complete prosthetic system. More specific, the purpose of these deliverables was...strap. The waist belt consists of an adjustable belt utilizing polypropylene buckles and a 2‖ elastic suspension strap which descends to the anchor ...Superior View. Step 8: The suspension component consists of a 1’ anchor strap with a buckle and a 5’ – 6’ long shoulder strap with hook and

  3. Artifacts by dental materials on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Choi, Deuk Lin; Kim, Ki Jung; Suh, Won Hyuck

    1992-01-01

    Magnetic resonance imaging (MRI) has proved to be a valuable method for evaluation of the head and neck. Unfortunately, metallic devices associated with certain dental fillings and appliances often cause variable artifacts that can obscure normal or pathologic conditions on MR and computed tomography. In this work, we assessed the MR appearance of dental prosthetic materials in vitro and in vivo including precious alloys, nonprecions alloys, resin, amalgam and titanium alloy. For in vivo studies, these materials were placed in healthy volunteer's mouths and then images were assessed. Analysis of the appearance of shape and extent of artifact, and observed influence of these artifacts on the image interpretation at 0.2 Tesla permanent type MR scanner were valuated. Material used as temporary or permanent filling of crowns such as amalgam, precious alloy and, microfilled resin did not cause artifact on the image. The size of the artifact produced by the nonprecious alloys was influenced by the ferromagnetism of the object and the volume prosthesis, and was related to the scanning sequence. Nonprecious alloys produced minimal local signal distortion, where precious alloys, and dental resin had no effect on the MR images in vivo. These results were mainly from a low field strength MR scanner used in this study

  4. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    Science.gov (United States)

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  5. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    Science.gov (United States)

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  6. The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants

    Directory of Open Access Journals (Sweden)

    Ali Fayaz

    2014-01-01

    Full Text Available Background: Mechanical torque limiting devices (MTLDs are necessary tools to control a peak torque and achieving target values of screw component of dental implants. Due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices (F-S MTLDs in achieving their target torque values. Materials and Methods: Peak torque measurements of 15 new F-S MTLDs from three different manufacturers (Astra Tech, BioHorizons, Dr. Idhe were measured ten times before and after 100 steam sterilization using a digital torque gauge. To simulate the clinical situation of aging (number of use target torque application process was repeated 10 times after each sterilization cycle and the peak torque values were registered. Comparison of the mean differences with target torque in each cycle was performed using one sample t test. Considering the type of MTLDs as inter subject comparison, One-way repeated measure ANOVA was used to evaluate the absolute values of differences between devices of each manufacturer in each group (α = 0.05. Results: The results of this study in Dr. Idhe group showed that, mean of difference values significantly differed from the target torque (P = 0.002 until 75 cycles. In Astra Tech group, also mean of difference values with under estimation trend, showed a significant difference with the target torque (P < 0.001. Mean of difference values significantly differed from the target torque with under estimation trend during all the 100 cycles in BioHorizons group (P < 0.05. Conclusion: The torque output of each individual device stayed in 10% difference from target torque values before 100 sterilization cycles, but more than 10% difference from the target torque was seen in varying degrees during these consequent cycles.

  7. Illusory movement perception improves motor control for prosthetic hands

    Science.gov (United States)

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  8. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  9. Augmenting retention and stability of an occlusal device for a partially dentate patient using existing extracoronal attachments: a clinical report.

    Science.gov (United States)

    Al-Rowaieh, Saleh A

    2011-04-01

    Occlusal devices are a valid treatment modality in certain clinical situations. For an occlusal device to be effective, sufficient retention and stability should be derived from coverage of the occlusal and incisal surfaces of the teeth. In the absence of most or all of the posterior teeth, the effectiveness of the device could become compromised as the incisal portions of the anterior teeth are typically not conducive to adequately retaining and stabilizing the device. This clinical report describes an approach to improving the retention and stability of an occlusal device for a patient with shortened dental arches by use of the patient's existing extracoronal attachments. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Science.gov (United States)

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  11. Accuracy of digital impression in dental implants: A literature review

    OpenAIRE

    Sudabe Kulivand; Maryam Moslemion

    2016-01-01

    Restoration of dental implants remains one of the most challenging aspects of implant dentistry. Although it is not clear whether prosthetic misfit could affect osseointegration, mechanical complications of implant-supported prostheses can be avoided by achieving a good passive fit between the framework and the implants. Passive fit is a difficult concept to define. Obtaining absolute passive fit of the prosthetic framework on implants has been reported to be nearly impossible. Because of ...

  12. Esthetic management of compromised ridge in the anterior maxilla, a modified prosthetic approach

    Directory of Open Access Journals (Sweden)

    R Lambodharan

    2017-01-01

    Full Text Available Replacing a missing tooth with an implant, especially in the esthetic zone has been increasing demand for the patient. Placing dental implants in the esthetic zone, especially in the compromised ridge with thin gingival thin biotype is considered to be the ultimate challenge for many dentists. This case report illustrates the implant placement in the traumatic anterior maxilla with thin gingival biotype (Class IV and a modified approach in prosthetic placement.

  13. Prosthetic rehabilitation of a preschooler with induced anodontia - A clinical report

    Directory of Open Access Journals (Sweden)

    Shivayogi M Hugar

    2011-01-01

    Full Text Available A case of prosthetic rehabilitation with complete dentures for a three year nine months old child is presented. Dental prosthesis are frequently used to avoid psychologic, speech, or swallowing problems in preschooler children. The case was followed up for a period of three years. These prosthesis were modified as the child grew and as the permanent teeth erupted into the oral cavity the dentures were trimmed from the areas of erupting teeth to facilitate their eruption.

  14. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    New, P.F.J.; Rosen, B.R.; Brady, T.J.

    1983-01-01

    The risks to patients with metal surgical implants who are undergoing nuclear magnetic resonance (NMR) imaging and the artifacts caused by such implants were studied. Twenty-one aneurysm and other hemostatic clips and a variety of other materials (e.g., dental amalgam, 14 karat gold) were used. Longitudinal forces and torques were found to be exerted upon 16 of the 21 clips. With five aneurysm clips, forces and torques sufficient to produce risk of hemorrhage from dislocation of the clip from the vessel or aneurysm, or cerebral injury by clip displacement without dislodgement were identified. The induced ferromagnetism was shown to be related to the composition of the alloys from which the clips were manufactured. Clips with 10-14% nickel are evidently without sufficient induced ferromagnetism to cause hazard. The extent of NMR imaging artifacts was greater for materials with measurable ferromagnetic properties, but metals without measurable ferromagnetism in our tests also resulted in significant artifacts. Dental amalgam and 14 karat gold produced no imaging artifacts, but stainless steels in dentures and orthodontic braces produced extensive artifacts in the facial region

  15. [The choice of color in fixed prosthetics: what steps should be followed for a reliable outcome?].

    Science.gov (United States)

    Vanheusden, Alain; Mainjot, Amélie

    2004-01-01

    The creation of a perfectly-matched esthetic fixed restoration is undeniably one of the most difficult challenges in modern dentistry. The final outcome depends on several essential steps: the use of an appropriate light source, the accurate analysis and correct evaluation of patient's teeth parameters (morphology, colour, surface texture,...), the clear and precise transmission of this data to the laboratory and the sound interpretation of it by a dental technician who masters esthetic prosthetic techniques perfectly. The purpose of this paper was to give a reproducible clinical method to the practitioner in order to achieve a reliable dental colorimetric analysis.

  16. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials

    Directory of Open Access Journals (Sweden)

    Ennio Bramanti

    2017-01-01

    Full Text Available The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  17. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials.

    Science.gov (United States)

    Bramanti, Ennio; Cervino, Gabriele; Lauritano, Floriana; Fiorillo, Luca; D'Amico, Cesare; Sambataro, Sergio; Denaro, Deborah; Famà, Fausto; Ierardo, Gaetano; Polimeni, Antonella; Cicciù, Marco

    2017-01-01

    The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  18. The method and device for thermoregulation and optimization of dental material′s quality and working time

    Directory of Open Access Journals (Sweden)

    Sajjad Ashnagar

    2016-01-01

    Full Text Available Introduction: No one can cast a shadow of doubt on the fact that temperature is a key element in dentistry. Temperature control enable dentists in a variety of clinical fields to perform more convenient. Frozen slab is a known method for manipulating temperature before mixing cements. But lack of precise temperature and infection control is bolded. Clinical innovation: The present apparatus determines a method for temperature control in routine dentistry tasks; namely restorative dentistry, prosthesis and even injections. This device is capable of whether heating or cooling materials using low voltage electricity. Peltier or thermoelectric effect is the mechanism behind this device. As operator sets a temperature, device would provide it via metal pads arranged on it in seconds. Discussion: Other common methods used in dentistry have some issues regarding power usage, infection control, size and etc. However, this device is small, cost effective, simple to use and has fast action. Infection control can be actively be maintained with it. This device is a promising alternative for this purpose. Present manuscript summarizes device properties and its potential utilities in dentistry.

  19. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.

    Science.gov (United States)

    Romero, Luis; Jiménez, Mariano; Espinosa, María Del Mar; Domínguez, Manuel

    2015-01-01

    This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.

  20. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.

    Directory of Open Access Journals (Sweden)

    Luis Romero

    Full Text Available This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system.From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data.Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.

  1. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations

    Science.gov (United States)

    Romero, Luis; Jiménez, Mariano; Espinosa, María del Mar; Domínguez, Manuel

    2015-01-01

    Aim This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. Method From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Results Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants. PMID:26696528

  2. Consumer satisfaction with the services of prosthetics and orthotics facilities.

    Science.gov (United States)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U

    2009-03-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (P&O) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 P&O facilities in The Netherlands. Consumers (n = 1,364) of these P&O facilities who were fitted with a prosthesis, orthopaedic shoes, an orthosis, or another device, were asked to rate the overall services provided and whether they were satisfied with the device provided and its delivery time. Additionally, they filled in a modified SERVQUAL questionnaire (see Appendix). Consumers gave the service provided by P&O facilities a mean overall rating of 8.1. The highest ratings were given by consumers fitted with a prosthesis (mean overall rating of services: 8.4). In total, 78% of the consumers were satisfied with the device provided and 93% with the delivery time. The results of our study showed that, on the SERVQUAL, 50% of the statements fulfilled the criteria for a satisfactory quality of the services. The overall consumer rating of the service provided by P&O facilities is high and depends on the device provided. The outcomes on the SERVQUAL were moderate. In future, it is important to study consumer satisfaction more extensively in order to improve the quality of P&O services in daily practice. Additionally, specific questionnaires need to be developed to measure all aspects of prosthetic and orthotic care, with the aim to improve the services.

  3. Prosthetic

    Directory of Open Access Journals (Sweden)

    Pokpong Amornvit

    2014-01-01

    Full Text Available Ocular trauma can be caused by road traffic accidents, falls, assaults, or work-related accidents. Enucleation is often indicated after ocular injury or for the treatment of intraocular tumors, severe ocular infections, and painful blind eyes. Rehabilitation of an enucleated socket without an intraocular implant or with an inappropriately sized implant can result in superior sulcus deepening, enophthalmos, ptosis, ectropion, and lower lid laxity, which are collectively known as post-enucleation socket syndrome. This clinical report describes the rehabilitation of post-enucleation socket syndrome with a modified ocular prosthesis. Modifications to the ocular prosthesis were performed to correct the ptosis, superior sulcus deepening, and enophthalmos. The rehabilitation procedure produced satisfactory results.

  4. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    Science.gov (United States)

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  5. An evaluation of prosthetic status and treatment needs among institutionalized elderly individuals of Delhi, India

    Directory of Open Access Journals (Sweden)

    Nisha Yadav

    2017-01-01

    Full Text Available Context: Oral health is essential for elderly person's general health and well-being. The most common oral problem in elderly is tooth loss which results due to periodontal diseases and caries. Prosthetic status is very important as it is related to dietary intake and maintaining nutritional status. Hence, to promote the oral health of the elderly, we need to know their prosthetic status and need. Aims: The aim of this study is to find the prosthetic status and need of 65–74 years old elderly residing in old age homes of Delhi, India. Settings and Design: A cross-sectional study was conducted among a total of 464 residents of 20 old age homes of Delhi, India. Material and Methods: Residents with age group of 64–75 were included in the study. The prosthetic status with treatment need was recorded using the World Health Organization Oral Health Assessment Form (1997. Statistical Analysis Used: Chi-square test and t-test were used to find significance of variables. P < 0.05 was considered significant. Results: Full removable dentures were worn by 7.30% of participants with predominance in upper arch, and one bridge was seen in 9.10% of participants with predominance in lower arch. Full removable denture was required in 25.20% of participants. Most of participants required multiunit prosthesis in both upper as well as lower arch (42.20% and 36.20%, respectively. Conclusion: The present study underlines a considerable need for dental treatment in elderly as the prosthetic status of participants was poor, and prosthetic needs were high.

  6. Maxillofacial prosthetic rehalibilation of the oral cancer patient

    International Nuclear Information System (INIS)

    Wolfaardt, J.F.; Monteith, B.D.

    1982-01-01

    The victim of orofacial cancer is frequently subjected to severe morphological and functional disturbance: a condition which the maxillofacial prosthetist can do much to alleviate through the use of various prosthetic devices. The successful rehabilitation of these patients, however, is often compromised by the presence of psychosocial and other problems, the solution of which extends beyond the limits of a single clinical discipline. The modern approach to orofacial cancer, therefore, is organised within the context of interdisciplinary co-operation: each phase of patient management being planed and executed according to the co-ordinated efforts of the various members of a head and neck cancer team

  7. Development and marketing of a prosthetic urinary control valve system

    Science.gov (United States)

    Tenney, J. B., Jr.; Rabinowitz, R.; Rogers, D. W.; Harrison, H. N.

    1983-01-01

    An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.

  8. Skeletal and dental stability after maxillary distraction with a rigid external device in adult cleft lip and palate patients.

    Science.gov (United States)

    Aksu, Muge; Saglam-Aydinatay, Banu; Akcan, Cenk Ahmet; El, Hakan; Taner, Tulin; Kocadereli, Ilken; Tuncbilek, Gokhan; Mavili, Mehmet Emin

    2010-02-01

    To evaluate skeletal and dental stability in adult cleft lip and palate patients treated with a rigid external distraction system at the end of distraction and during the postdistraction period. Lateral cephalograms of 7 patients were obtained before distraction, at the end of distraction, and during the postdistraction period. The mean age before distraction was 21.56 +/- 4.73 years. The mean follow-up was 37.3 +/- 12.4 months. The assessment of findings showed that skeletal maxillary sagittal movement was achieved in a superoanterior direction. The maxillary depth angle and effective maxillary length increased significantly (2 degrees and 9 mm, respectively) after distraction, whereas the palatal plane angle increased by 8 degrees , resulting in an anterior movement of the maxilla with a counterclockwise rotation. The lower facial height showed no significant changes after distraction. The sagittal movement of the upper incisors and the angulation of the upper first molars increased significantly (4.5 mm and 5.5 degrees , respectively). During the postdistraction period, the maxilla showed a slight relapse (22%). The effective maxillary length decreased by 2 mm. The palatal plane angle almost returned to its original position, showing 7 degrees of clockwise rotation. The lower facial height remained stable. The upper incisors moved anteriorly and the upper first molars showed a significant mesioangular change during follow-up. After distraction, significant maxillary advancement was achieved with a counterclockwise rotation. The upper incisors moved labially, and the upper first molars angulated mesially. After 3 years, a 22% relapse rate was seen in the maxilla. The counterclockwise rotation of the maxilla was returned to its original position. The upper incisors moved more anteriorly. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Zirconia based dental ceramics: structure, mechanical properties, biocompatibility and applications.

    Science.gov (United States)

    Gautam, Chandkiram; Joyner, Jarin; Gautam, Amarendra; Rao, Jitendra; Vajtai, Robert

    2016-12-06

    Zirconia (ZrO 2 ) based dental ceramics have been considered to be advantageous materials with adequate mechanical properties for the manufacturing of medical devices. Due to its very high compression strength of 2000 MPa, ZrO 2 can resist differing mechanical environments. During the crack propagation on the application of stress on the surface of ZrO 2 , a crystalline modification diminishes the propagation of cracks. In addition, zirconia's biocompatibility has been studied in vivo, leading to the observation of no adverse response upon the insertion of ZrO 2 samples into the bone or muscle. In vitro experimentation has exhibited the absence of mutations and good viability of cells cultured on this material leading to the use of ZrO 2 in the manufacturing of hip head prostheses. The mechanical properties of zirconia fixed partial dentures (FPDs) have proven to be superior to other ceramic/composite restorations and hence leading to their significant applications in implant supported rehabilitations. Recent developments were focused on the synthesis of zirconia based dental materials. More recently, zirconia has been introduced in prosthetic dentistry for the fabrication of crowns and fixed partial dentures in combination with computer aided design/computer aided manufacturing (CAD/CAM) techniques. This systematic review covers the results of past as well as recent scientific studies on the properties of zirconia based ceramics such as their specific compositions, microstructures, mechanical strength, biocompatibility and other applications in dentistry.

  10. Tooth loss, prosthetic status and treatment needs among industrial workers in Belgaum, Karnataka, India.

    Science.gov (United States)

    Patil, Vishal V; Shigli, Kamal; Hebbal, Mamata; Agrawal, Neha

    2012-01-01

    The health of industrial workers often goes uncared for due to their stressful working conditions, busy schedules and poor economic conditions. A cross-sectional survey was conducted to determine the prevalence of tooth loss, prosthetic status and treatment needs among industrial workers in Belgaum, Karnataka, India according to the criteria described in the World Health Organization (WHO) Oral Health Assessment form (1997). A total of 614 workers participated in the study. Information was obtained regarding their oral hygiene practice. The presence or absence of habits, and the frequency and duration since the last visit to a dentist were recorded followed by clinical examination. Chi-square test was used to determine the association between the variables and tooth loss. There was a statistically significant difference between the number of missing teeth in different age groups, methods of cleaning, smoking habits and visits to the dentist. Regarding prosthetic status, only one worker had a fixed prosthesis in the mandibular arch. The study revealed that tooth loss was associated with oral hygiene practices, habits and visits to the dentist. Poor prosthetic status and high treatment needs were observed. This study emphasized the need for improved dental health awareness and availability of dental facilities to industrial workers.

  11. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  12. DME Prosthetics Orthotics, and Supplies Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Durable Medical Equipment, Prosthetics-Orthotics, and Supplies Fee Schedule. The list contains the fee schedule amounts, floors, and ceilings for all procedure codes...

  13. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  14. [Application and outlook of three-dimensional printing in prosthetic dentistry].

    Science.gov (United States)

    Sun, Y C; Li, R; Zhou, Y S; Wang, Y

    2017-06-09

    At present, three-dimensional (3D) printing has been applied in many aspects in the field of prosthodontics, such as dental models, wax patterns, guide plates, dental restoration and customized implants. The common forming principles include light curing, sintering and melting-condensation, the materials include pure wax, resin, metal and ceramics. However, the printing precision and the strength of multi-material integrated forming, remains to be improved. In addition, as a technology by which the internal structure of a material can be customized manufacturing, further advantage of 3D printing used in the manufacture of dental restoration lies in the customization functional bionic micro-structures, but the related research is still in its infancy. The review briefly summarizes the commonly used 3D printing crafts in prosthetic dentistry, and details clinical applications and evaluations, provides references for clinical decision and further research.

  15. REFRACTORY CEPHALEA AND RHINITIS FOLLOWING DENTAL IMPLANT

    Directory of Open Access Journals (Sweden)

    ENRIQUE COSCARÓN-BLANCO

    2018-05-01

    Full Text Available INTRODUCTION: Dental implants are prosthetic devices that are inserted into the thickness of the bone of the maxilla for osseointegration using a screw system. They are increasingly used for both functional and aesthetic reasons. As in any medical or surgical procedure, there are some typical risks and possible sequelae that must be explained and prevented. However, sometimes not-associated-with-implantation rare complications that can cause great morbidity and decrease in the quality of life of the implant recipient can occur. A case of an unusual complication is reported,MATERIAL AND METHODS: A 65-year-old woman presented with a permanent mainly right-sided bilateral nasal obstruction with frequent watery rhinorrhea and headache with retro-orbital and infraorbital irradiation refractory to broad-spectrum antibiotic treatment, corticosteroids and analgesics that she associated with a dental implant two weeks before. . Sinusitis or implant-related complication were ruled out by the dentist and her Primary Care Physician, and therefore she was referred to otorhinolaryngological assessment after radiological study with maxillary sinuses free of disease. The physical examination demostrated inferior obstructive hypertrophic turbinates from the anterior third and thick clear rhinorrhea. After topic tetracaine with adrenaline ,retraction of the turbinates revealed a screw that after breaking the floor of the right nostril entered the thickness of the inferior turbinate. In the left nostril, soil procidence is identified with turbinal contact. An orthopantomography demonstrated the findings described above, highlighting also how the implant was inserted into the skeleton of the inferior turbinate. The sympthoms resolved after removal of the implant. Topical oxymetazoline and corticosteroids provided little relief meanwhile. DISCUSSION AND CONCLUSIONS: The functional objectives sought with dental implants can be compromised by complications such as the

  16. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    Directory of Open Access Journals (Sweden)

    Manelle Merad

    2018-02-01

    Full Text Available Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals

  17. Isolated Lactobacillus chronic prosthetic knee infection.

    Science.gov (United States)

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  18. Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction

    NARCIS (Netherlands)

    Schepers, Rutger H.; Raghoebar, Gerry M.; Vissink, Arjan; Lahoda, Lars U.; Van der Meer, W. Joerd; Roodenburg, Jan L.; Reintsema, Harry; Witjes, Max J.

    Background Reconstruction of craniofacial defects becomes complex when dental implants are included for functional rehabilitation. We describe a fully 3-dimensional (3D) digitally planned reconstruction of a mandible and immediate prosthetic loading with a fibula graft in a 2-step surgical approach.

  19. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  20. Cetacean Swimming with Prosthetic Limbs

    Science.gov (United States)

    Bode-Oke, Ayodeji; Ren, Yan; Dong, Haibo; Fish, Frank

    2016-11-01

    During entanglement in fishing gear, dolphins can suffer abrasions and amputations of flukes and fins. As a result, if the dolphin survives the ordeal, swimming performance is altered. Current rehabilitation technques is the use of prosthesis to regain swimming ability. In this work, analyses are focused on two dolphins with locomotive impairment; Winter (currently living in Clearwater Marine Aquarium in Florida) and Fuji (lived in Okinawa Churaumi Aquarium in Japan). Fuji lost about 75% of its fluke surface to necrosis (death of cells) and Winter lost its tail due to amputation. Both dolphins are aided by prosthetic tails that mimic the shape of a real dolphin tail. Using 3D surface reconstruction techniques and a high fidelity Computational Fluid Dynamics (CFD) flow solver, we were able to elucidate the kinematics and hydrodynamics and fluke deformation of these swimmers to clarify the effectiveness of prostheses in helping the dolphins regain their swimming ability. Associated with the performance, we identified distinct features in the wake structures that can explain this gap in the performance compared to a healthy dolphin. This work was supported by ONR MURI Grant Number N00014-14-1-0533.

  1. State of the art of medical devices featuring smart electro-rheological and magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    Jong-Seok Oh

    2017-10-01

    Full Text Available Recently, smart fluids have drawn significant attention and growing a great interest in a broad range of engineering applications such as automotive and medical areas. In this article, two smart fluids called electro-rheological (ER fluid and magneto-rheological (MR fluid are reviewed in terms of medical applications. Especially, this article describes the attributes and inherent properties of individual medical and rehabilitation devices. The devices surveyed in this article include multi-degree-of-freedom haptic masters for robot surgery, thin membrane touch panels for braille readers, sponge-like tactile sensors to feel human tissues such as liver, rehabilitation systems such as prosthetic leg, and haptic interfaces for dental implant surgery. The operating principle, inherent characteristics and practical feasibility of each medical device or system are fully discussed in details.

  2. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand.

    Science.gov (United States)

    Pasquina, Paul F; Evangelista, Melissa; Carvalho, A J; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David

    2015-04-15

    Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. Implantable Myoelectric Sensors (IMES(®)) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electro-magnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. We report the status of the first FDA-approved clinical trial of the IMES(®) System. This study is currently in progress, limiting reporting to only preliminary results. Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. The interim results of this study indicate the feasibility of utilizing IMES(®) technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    Science.gov (United States)

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  4. Oral health-related quality of life and prosthetic status of nursing home residents with or without dementia.

    Science.gov (United States)

    Klotz, Anna-Luisa; Hassel, Alexander Jochen; Schröder, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

    2017-01-01

    The objective of this cross-sectional study was to evaluate the effect of prosthetic status on the oral health-related quality of life (OHRQoL) of nursing home residents with or without dementia. The study was performed in 14 nursing homes across the federal state of Baden-Württemberg, Germany. All eligible participants were included, and general and medical information and information about their dental and prosthetic statuses were collected. The Geriatric Oral Health Assessment Index (GOHAI) was administered to evaluate OHRQoL. The Mini-Mental State Examination (MMSE) served to classify participants into living or not living with dementia according to the established cutoff value for dementia (MMSE health was also similar in both groups ( P >0.05). The number of teeth (odds ratio [OR]: 2.0), the type of prosthetic status (OR: 6.5), and denture-related treatment needs (OR: 2.4) were the major factors significantly affecting OHRQoL ( P nursing home residents is substantially compromised. Several prosthetic treatment needs for residents living with or without dementia were identified. Edentulism without tooth replacement and having <5 teeth resulted in an increased risk of substantially compromised OHRQoL. Further studies should be conducted to determine whether improvements in prosthetic status can increase OHRQoL.

  5. Dental esthetics--instrument for recreating a new facial esthetic to the elderly patient.

    Science.gov (United States)

    Scutariu, Mihaela Monica; Forna, Norina

    2014-01-01

    The major objective of this paper consists in underlining the wide range of possibilities in assessing the elderly patient; it relies on clinical examination in order to exclusively improve the patient's physiognomic aspect. In this context it has been organized a study which included 64 elderly patients aged between 60 and 90 years of age (median age 75), which presented themselves at the Clinical Service of Dental Semiology and Gerontostomatology between 2011-2012; they requested the restoration of the functions affected by odontal coronary lesions, periodontal disorders or edentations more or less expanded, malocclusions, malrelations of the mandible to the skull and unsuccessful or deteriorated dental or prosthetic treatments. The restoration of dental arches has been performed relying on common sense and power of discernment, respecting both facial features and expression by redimensioning the lower part of the face, repositioning the mandible and using gnatoprosthetic devices. Solving the problems elderly patients confront themselves with and the success of the treatment has been possible only after a correct assessment of the involutive phenomena that influence the oral cavity, after understanding the local and general factors that predispose to oral disorders as well as the differences between various techniques and materials.

  6. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  7. The influence of environmental and personal factors on participation of lower-limb prosthetic users in low-income countries: prosthetists' perspectives.

    Science.gov (United States)

    Kam, Season; Kent, Mallory; Khodaverdian, Alin; Daiter, Liane; Njelesani, Janet; Cameron, Debra; Andrysek, Jan

    2015-05-01

    To examine the environmental and personal factors in low-income countries (LICs) that influence prosthetic rehabilitation of adults with lower-limb (LL) amputations and their ability to participate in daily activities. In this qualitative descriptive study, 11 prosthetists participated in semi-structured interviews by telephone or Skype. Qualitative thematic analysis was guided by the International Classification of Function. Facilitating continuity of care, consideration of physical environments and usage, prosthetic quality including durability and socket fit, and minimizing the visibility of disability, were found to be important factors affecting the provision of prosthetic services in LICs. Environmental and personal factors must be considered when providing prosthetic rehabilitation for adults with LL amputations in LICs in order to optimize participation in activities. Results from this study provide new insights about some of the factors that influence the ability of individuals with LL amputations to rehabilitate to a level where they are able to participate in meaningful activities within their communities. There are unique environmental and personal components that can influence activity and participation of lower-limb (LL) prosthetic users in low-income countries (LICs). These components are often overlooked in the design of prosthetic devices and provision of prosthetic services. Continuity of care, condition of the post-surgical residuum, outdoor environments of common occupations, aesthetics and durability of prostheses, and user comfort should all be considered when providing prosthetic rehabilitation to adults with LL amputations in LICs to promote activity and participation. Results of our study can inform the practice of prosthetists in LICs by highlighting their contributions in enabling participation for LL prosthetic users. Our results can also inform the design of durable and comfortable prostheses and the provision of more appropriate

  8. Dynamic Facial Prosthetics for Sufferers of Facial Paralysis

    Directory of Open Access Journals (Sweden)

    Fergal Coulter

    2011-10-01

    Full Text Available BackgroundThis paper discusses the various methods and the materialsfor the fabrication of active artificial facial muscles. Theprimary use for these will be the reanimation of paralysedor atrophied muscles in sufferers of non-recoverableunilateral facial paralysis.MethodThe prosthetic solution described in this paper is based onsensing muscle motion of the contralateral healthy musclesand replicating that motion across a patient’s paralysed sideof the face, via solid state and thin film actuators. Thedevelopment of this facial prosthetic device focused onrecreating a varying intensity smile, with emphasis ontiming, displacement and the appearance of the wrinklesand folds that commonly appear around the nose and eyesduring the expression.An animatronic face was constructed with actuations beingmade to a silicone representation musculature, usingmultiple shape-memory alloy cascades. Alongside theartificial muscle physical prototype, a facial expressionrecognition software system was constructed. This formsthe basis of an automated calibration and reconfigurationsystem for the artificial muscles following implantation, soas to suit the implantee’s unique physiognomy.ResultsAn animatronic model face with silicone musculature wasdesigned and built to evaluate the performance of ShapeMemory Alloy artificial muscles, their power controlcircuitry and software control systems. A dual facial motionsensing system was designed to allow real time control overmodel – a piezoresistive flex sensor to measure physicalmotion, and a computer vision system to evaluate real toartificial muscle performance.Analysis of various facial expressions in real subjects wasmade, which give useful data upon which to base thesystems parameter limits.ConclusionThe system performed well, and the various strengths andshortcomings of the materials and methods are reviewedand considered for the next research phase, when newpolymer based artificial muscles are constructed

  9. Magnetic Oculomotor Prosthetics for Acquired Nystagmus.

    Science.gov (United States)

    Nachev, Parashkev; Rose, Geoff E; Verity, David H; Manohar, Sanjay G; MacKenzie, Kelly; Adams, Gill; Theodorou, Maria; Pankhurst, Quentin A; Kennard, Christopher

    2017-10-01

    Acquired nystagmus, a highly symptomatic consequence of damage to the substrates of oculomotor control, often is resistant to pharmacotherapy. Although heterogeneous in its neural cause, its expression is unified at the effector-the eye muscles themselves-where physical damping of the oscillation offers an alternative approach. Because direct surgical fixation would immobilize the globe, action at a distance is required to damp the oscillation at the point of fixation, allowing unhindered gaze shifts at other times. Implementing this idea magnetically, herein we describe the successful implantation of a novel magnetic oculomotor prosthesis in a patient. Case report of a pilot, experimental intervention. A 49-year-old man with longstanding, medication-resistant, upbeat nystagmus resulting from a paraneoplastic syndrome caused by stage 2A, grade I, nodular sclerosing Hodgkin's lymphoma. We designed a 2-part, titanium-encased, rare-earth magnet oculomotor prosthesis, powered to damp nystagmus without interfering with the larger forces involved in saccades. Its damping effects were confirmed when applied externally. We proceeded to implant the device in the patient, comparing visual functions and high-resolution oculography before and after implantation and monitoring the patient for more than 4 years after surgery. We recorded Snellen visual acuity before and after intervention, as well as the amplitude, drift velocity, frequency, and intensity of the nystagmus in each eye. The patient reported a clinically significant improvement of 1 line of Snellen acuity (from 6/9 bilaterally to 6/6 on the left and 6/5-2 on the right), reflecting an objectively measured reduction in the amplitude, drift velocity, frequency, and intensity of the nystagmus. These improvements were maintained throughout a follow-up of 4 years and enabled him to return to paid employment. This work opens a new field of implantable therapeutic devices-oculomotor prosthetics-designed to modify eye

  10. A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, John Kyle P [ORNL; Ericson, Milton Nance [ORNL; Farquhar, Ethan [ORNL; Lind, Randall F [ORNL; Evans III, Boyd Mccutchen [ORNL

    2011-01-01

    Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

  11. A geometrical optimization of a magneto-rheological rotary brake in a prosthetic knee

    International Nuclear Information System (INIS)

    Gudmundsson, K H; Jonsdottir, F; Thorsteinsson, F

    2010-01-01

    Magneto-rheological (MR) fluids have been successfully introduced to prosthetic devices. One such device is a biomechanical prosthetic knee that uses MR fluids to actively control its rotary stiffness. The brake is rotational, utilizing the MR fluid in shear mode. In this study, the geometrical design of the MR brake is addressed. This includes the design of the magnetic circuit and the geometry of the fluid chamber. Mathematical models are presented that describe the rotary torque of the brake. A novel perfluorinated polyether (PFPE)-based MR fluid is introduced, whose properties are tailored for the prosthetic knee. On-state and off-state rheological measurements of the MR fluid are presented. The finite element method is used to evaluate the magnetic flux density in the MR fluid. The design is formulated as an optimization problem, aiming to maximize the braking torque. A parametric study is carried out for several design parameters. Subsequently, a multi-objective optimization problem is defined that considers three design objectives: the field-induced braking torque, the off-state rotary stiffness and the weight of the brake. Trade-offs between the three design objectives are investigated which provides a basis for informed design decisions on furthering the success of the MR prosthetic knee

  12. Restorative Rehabilitation of a Patient with Dental Erosion.

    Science.gov (United States)

    AlShahrani, Mohammed Thamer; Haralur, Satheesh B; Alqarni, Mohammed

    2017-01-01

    Dental erosion is the chemical dissolution of the tooth structure. Factors like eating disorders and gastrointestinal diseases are recognized as intrinsic factors for dental erosion. Advanced stages of dental erosion extensively damage the tooth morphology, consequently affecting both esthetics and functions. Reports indicate the growing prevalence of erosion, and hence knowledge of restorative rehabilitation of tooth erosion is an integral part of the contemporary dental practice. This clinical report describes an adult patient with gastroesophageal reflux induced dental erosion involving the palatal surface of the maxillary anterior teeth. The extensive involvement of the palatal surfaces compromised the esthetics, incisal guidance, and functional occlusal efficiency. Indirect all-ceramic restorations were utilized to restore the esthetics and occlusal reconstruction. In conclusion, patients affected by severe dental erosion require prosthetic rehabilitation besides the management of the associated medical condition.

  13. Restorative Rehabilitation of a Patient with Dental Erosion

    Directory of Open Access Journals (Sweden)

    Mohammed Thamer AlShahrani

    2017-01-01

    Full Text Available Dental erosion is the chemical dissolution of the tooth structure. Factors like eating disorders and gastrointestinal diseases are recognized as intrinsic factors for dental erosion. Advanced stages of dental erosion extensively damage the tooth morphology, consequently affecting both esthetics and functions. Reports indicate the growing prevalence of erosion, and hence knowledge of restorative rehabilitation of tooth erosion is an integral part of the contemporary dental practice. This clinical report describes an adult patient with gastroesophageal reflux induced dental erosion involving the palatal surface of the maxillary anterior teeth. The extensive involvement of the palatal surfaces compromised the esthetics, incisal guidance, and functional occlusal efficiency. Indirect all-ceramic restorations were utilized to restore the esthetics and occlusal reconstruction. In conclusion, patients affected by severe dental erosion require prosthetic rehabilitation besides the management of the associated medical condition.

  14. Dental Abnormalities in Pituitary Dwarfism: A Case Report and Review of the Literature

    OpenAIRE

    Ferrante, Franco; Blasi, Sergio; Crippa, Rolando; Angiero, Francesca

    2017-01-01

    Hypopituitarism is a disorder caused by a reduced level of trophic hormones that may be consequent on different destructive processes. The clinical manifestations depend on the type of hormone involved. A deficiency of growth hormone (GH) in children causes the lack of growth known as pituitary dwarfism. The case is reported of a patient with pituitary dwarfism, multiple dental anomalies, functional prosthetic problems, and a revision of the literature. She was subjected to prosthetic rehabil...

  15. Development and evaluation of a digital dental modeling method based on grating projection and reverse engineering software.

    Science.gov (United States)

    Zhou, Qin; Wang, Zhenzhen; Chen, Jun; Song, Jun; Chen, Lu; Lu, Yi

    2016-01-01

    For reasons of convenience and economy, attempts have been made to transform traditional dental gypsum casts into 3-dimensional (3D) digital casts. Different scanning devices have been developed to generate digital casts; however, each has its own limitations and disadvantages. The purpose of this study was to develop an advanced method for the 3D reproduction of dental casts by using a high-speed grating projection system and noncontact reverse engineering (RE) software and to evaluate the accuracy of the method. The methods consisted of 3 main steps: the scanning and acquisition of 3D dental cast data with a high-resolution grating projection system, the reconstruction and measurement of digital casts with RE software, and the evaluation of the accuracy of this method using 20 dental gypsum casts. The common anatomic landmarks were measured directly on the gypsum casts with a Vernier caliper and on the 3D digital casts with the Geomagic software measurement tool. Data were statistically assessed with the t test. The grating projection system had a rapid scanning speed, and smooth 3D dental casts were obtained. The mean differences between the gypsum and 3D measurements were approximately 0.05 mm, and no statistically significant differences were found between the 2 methods (P>.05), except for the measurements of the incisor tooth width and maxillary arch length. A method for the 3D reconstruction of dental casts was developed by using a grating projection system and RE software. The accuracy of the casts generated using the grating projection system was comparable with that of the gypsum casts. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Validation of the prosthetic esthetic index

    DEFF Research Database (Denmark)

    Özhayat, Esben B; Dannemand, Katrine

    2014-01-01

    OBJECTIVES: In order to diagnose impaired esthetics and evaluate treatments for these, it is crucial to evaluate all aspects of oral and prosthetic esthetics. No professionally administered index currently exists that sufficiently encompasses comprehensive prosthetic esthetics. This study aimed...... to validate a new comprehensive index, the Prosthetic Esthetic Index (PEI), for professional evaluation of esthetics in prosthodontic patients. MATERIAL AND METHODS: The content, criterion, and construct validity; the test-retest, inter-rater, and internal consistency reliability; and the sensitivity...... furthermore distinguish between participants and controls, indicating sufficient sensitivity. CONCLUSION: The PEI is considered a valid and reliable instrument involving sufficient aspects for assessment of the professionally evaluated esthetics in prosthodontic patients. CLINICAL RELEVANCE...

  18. Ten questions on prosthetic shoulder infection.

    Science.gov (United States)

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  19. Prosthetic rehabilitation in a pediatric patient with hypohidrotic ectodermal dysplasia: a case report.

    Science.gov (United States)

    Quintanilha, Luís Eduardo Lavigne Paranhos; Carneiro-Campos, Luís Eduardo; Antunes, Lívia Azeredo Alves; Antunes, Leonardo Santos; Fernandes, Claudio Pinheiro; Abreu, Fernanda Volpe

    2017-01-01

    Hypohidrotic ectodermal dysplasia (HED) is a rare ectodermal disease with a systemic expression. Oral abnormalities are common and may include hypodontia and shape irregularities in the primary and permanent dentitions. Rehabilitation of the dental arches in pediatric patients with HED is a challenge because HED is a multifactorial disease that demands a complicated treatment approach and most dentists have limited experience or training in the necessary treatment. In addition, pediatric patients often lack the patience or ability to cooperate with complex prosthetic treatment. This case report describes a simplified technique used to fabricate complete dentures for a 4-year-old HED patient in 4 sessions.

  20. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  1. Illusory movement perception improves motor control for prosthetic hands.

    Science.gov (United States)

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  2. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  3. Dental cavities

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001055.htm Dental cavities To use the sharing features on this page, please enable JavaScript. Dental cavities are holes (or structural damage) in the ...

  4. Dental sealants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  5. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  6. Prosthetic clone and natural human tooth comparison by speckle interferometry

    Science.gov (United States)

    Slangen, Pierre; Corn, Stephane; Fages, Michel; Raynal, Jacques; Cuisinier, Frederic J. G.

    2010-09-01

    New trends in dental prosthodontic interventions tend to preserve the maximum of "body" structure. With the evolution of CAD-CAM techniques, it is now possible to measure "in mouth" the remaining dental tissues. The prosthetic crown is then designed using this shape on which it will be glued on, and also by taking into account the contact surface of the opposite jaw tooth. Several theories discuss on the glue thickness and formulation, but also on the way to evolve to a more biocompatible crown and also new biomechanical concepts. In order to validate these new concepts and materials, and to study the mechanical properties and mechanical integrity of the prosthesis, high resolution optical measurements of the deformations of the glue and the crown are needed. Samples are two intact premolars extracted for orthodontics reasons. The reference sample has no modifications on the tooth while the second sample tooth is shaped to receive a feldspathic ceramic monoblock crown which will be glued. This crown was manufactured with a chairside CAD-CAM system from an intra-oral optical print. The software allows to realize a nearly perfect clone of the reference sample. The necessary space for the glue is also entered with ideal values. This duplication process yields to obtain two samples with identical anatomy for further processing. The glue joint thickness can also be modified if required. The purpose is to compare the behaviour of a natural tooth and its prosthetic clone manufactured with "biomechanical" concepts. Vertical cut samples have been used to deal with planar object observation, and also to look "inside" the tooth. We have developed a complete apparatus enabling the study of the compressive mechanical behaviour of the concerned tooth by speckle interferometry. Because in plane displacements are of great interest for orthodontic measurements1, an optical fiber in-plane sensitive interferometer has been designed. The fibers are wrapped around piezoelectric

  7. Dental negligence.

    Science.gov (United States)

    Tay, C S

    2000-02-01

    Medical and dental errors and negligence are again in the spotlight in recent news report. Dead because of doctor's bad handwriting Prescribing drug overdoses Germ-infested soap pumps--infections in hospitals This articles explains dental negligence including dental duty of care and the standard of care expected of dentists in relation to the Bolam principle.

  8. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  9. Tactile Sensing Reflexes for Advanced Prosthetic Hands

    Science.gov (United States)

    2016-10-01

    Jeremy A. Fishel, Member, IEEE Figure 1. A) Custom NumaTac prosthetic fingertip sensor core and foam; B) Ottobock VariPlus Speed hand installed with two...oal – H ardw are P rototype D evelopm ent R   Identify alternatives for outcom e m easures R   E xplore sensor design param eters C Y16 G oals – C

  10. Prosthetic Management of Patients Presenting with Juvenile ...

    African Journals Online (AJOL)

    Eighteen were referred for prosthetic replacement. Their age ranged between 18 and 36 years. A total of 24 removable partial dentures were fabricated, 17[70.8%] were kennedy class III type, of which 11[64.7%] had the bounded saddle located in the anterior segment. Majority 8[44.4%] of the patients had 2-4 teeth replaced ...

  11. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  12. Multimodality Imaging Assessment of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Suchá, D.; Symersky, Petr; Tanis, W; Mali, Willem P Th M; Leiner, Tim; van Herwerden, LA; Budde, Ricardo P J

    Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have

  13. The Prosthetic Experience Between Body and Technology

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2018-01-01

    In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling...

  14. Consumer satisfaction in prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Gankema, H.G.J.; Groothoff, J.W.; Dijkstra, P.U.

    The aim of this study was to assess consumer/patient satisfaction with the services of the prosthetics and orthotics (P&O) facilities in the north of the Netherlands, using a modified SERVQUAL questionnaire. In this questionnaire, consumer interests and experiences are assessed on a 5-point Likert

  15. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  16. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  18. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  19. Method of making self-cleaning skin-like prosthetic polymer surfaces

    Science.gov (United States)

    Simpson, John T.; Ivanov, Ilia N.; Shibata, Jason

    2017-06-06

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  20. Mechanical design of a shape memory alloy actuated prosthetic hand.

    Science.gov (United States)

    De Laurentis, Kathryn J; Mavroidis, Constantinos

    2002-01-01

    This paper presents the mechanical design for a new five fingered, twenty degree-of-freedom dexterous hand patterned after human anatomy and actuated by Shape Memory Alloy artificial muscles. Two experimental prototypes of a finger, one fabricated by traditional means and another fabricated by rapid prototyping techniques, are described and used to evaluate the design. An important aspect of the Rapid Prototype technique used here is that this multi-articulated hand will be fabricated in one step, without requiring assembly, while maintaining its desired mobility. The use of Shape Memory Alloy actuators combined with the rapid fabrication of the non-assembly type hand, reduce considerably its weight and fabrication time. Therefore, the focus of this paper is the mechanical design of a dexterous hand that combines Rapid Prototype techniques and smart actuators. The type of robotic hand described in this paper can be utilized for applications requiring low weight, compactness, and dexterity such as prosthetic devices, space and planetary exploration.

  1. Psychometric evaluation of self-report outcome measures for prosthetic applications

    OpenAIRE

    Hafner, Brian J.; Morgan, Sara J.; Askew, Robert L.; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of impo...

  2. Bulletin of Prosthetics Research. Rehabilitative Engineering Research and Development, Volume 18, Number 2, Fall 1981,

    Science.gov (United States)

    1981-01-01

    of 140 beats per minute Upper limb prosthetic terminal devices have remained un- could either crutch walk at 60 meters per minute or run at 134...Responses During Binaural Stimulation, TN. Decker and S.W. Howe; J. Functional Effectiveness of a Myo-Electric Prosthesis Compared Acoust. Soc. Amer., 69(4...were whether the aid(s) should be fitted monaurally, binaurally or fitted with hearing aids. Of these, roughly 9,000 were CROS. About 95 percent of

  3. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    Science.gov (United States)

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  4. 42 CFR 421.210 - Designations of regional carriers to process claims for durable medical equipment, prosthetics...

    Science.gov (United States)

    2010-10-01

    ..., Arizona, Washington, Oregon, Montana, Idaho, Utah, Wyoming, North Dakota, South Dakota, Nebraska, Kansas... based on sections 1834(a)(12) and 1834(h) of the Act, which authorize the Secretary to designate one... equipment (and related supplies) as defined in section 1861(n) of the Act; (2) Prosthetic devices (and...

  5. Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences.

    Science.gov (United States)

    Zuniga, Jorge; Katsavelis, Dimitrios; Peck, Jean; Stollberg, John; Petrykowski, Marc; Carson, Adam; Fernandez, Cristina

    2015-01-20

    There is an increasing number of children with traumatic and congenital hand amputations or reductions. Children's prosthetic needs are complex due to their small size, constant growth, and psychosocial development. Families' financial resources play a crucial role in the prescription of prostheses for their children, especially when private insurance and public funding are insufficient. Electric-powered (i.e., myoelectric) and body-powered (i.e., mechanical) devices have been developed to accommodate children's needs, but the cost of maintenance and replacement represents an obstacle for many families. Due to the complexity and high cost of these prosthetic hands, they are not accessible to children from low-income, uninsured families or to children from developing countries. Advancements in computer-aided design (CAD) programs, additive manufacturing, and image editing software offer the possibility of designing, printing, and fitting prosthetic hands devices at a distance and at very low cost. The purpose of this preliminary investigation was to describe a low-cost three-dimensional (3D)-printed prosthetic hand for children with upper-limb reductions and to propose a prosthesis fitting methodology that can be performed at a distance. No significant mean differences were found between the anthropometric and range of motion measurements taken directly from the upper limbs of subjects versus those extracted from photographs. The Bland and Altman plots show no major bias and narrow limits of agreements for lengths and widths and small bias and wider limits of agreements for the range of motion measurements. The main finding of the survey was that our prosthetic device may have a significant potential to positively impact quality of life and daily usage, and can be incorporated in several activities at home and in school. This investigation describes a low-cost 3D-printed prosthetic hand for children and proposes a distance fitting procedure. The Cyborg Beast

  6. Prosthetic Need between Different Age and Gender ‎With Patient Attending College of Dentistry,Tikrit ‎University

    Directory of Open Access Journals (Sweden)

    Reem Ahmed Shihab‎

    2017-12-01

    Full Text Available Background: the most important factor that affects speak, mastication and aesthetics is tooth loss which in turn imitated on the quality of life. The goal of our research was to evaluate the prosthetic need in sample attending prosthetic department and compare between age and gender. Material and methods: A sample of 244 patients was randomly chosen for questionnaire in the (Removable Prosthodontics Clinic into College of Dentistry-Tikrit University. All subjects were divided in six groups according to their age and also divided according to gender. Intraoral examinations were performed and reasons for extraction were recorded. All statistic calculations were performed using SPSS 23 (Statistical Package for Social Sciences. Results: The total number of 244 patients was involved in this study: 165 (67.6% males and 79 (32.4% females. We found that the higher percentage of patients were in the age group of (20-29 for males which was (23%, 56 patient, while the higher female percentage was found in the age group of (40-49 which was 11.5% . Reasons for extraction recorded the higher percentage due to Caries for both males (75.2% & females (81 % as suspected. Conclusion:The number of patient attending prosthetic department male more than female. Dental caries were the principal cause for extractions in younger patients followed by periodontitis. Society needs more motivation about dental health and care.

  7. Mitral Prosthetic Valve Obstruction and Its Complications

    Directory of Open Access Journals (Sweden)

    Rajesh Rajan

    2015-12-01

    Full Text Available Prosthetic Valve Obstruction (PVO is a serious complication which is associated with increased morbidity and mortality. This could result from thrombus formation, development of pannus, or a combination of both. Patients with this complication often present with symptoms and signs of heart failure, systemic embolism, acute cardiovascular collapse, and sudden death. Transesophageal echocardiography and cine fluoroscopy play a vital role in diagnosis of this potentially lethal condition. Herein, we reported a 56-year-old male patient who presented with severe heart failure and was found to have obstructed ATS27 bileaflet mitral prosthetic valve. Thrombolysis and redo surgery are two important options for treating this condition although guidelines for choosing between the two are not very definite.

  8. Prosthetic valve obstruction: Redo surgery or fibrinolysis?

    Directory of Open Access Journals (Sweden)

    Avinash Inamdar

    2017-01-01

    Full Text Available Objective: The aim of this study was to compare the efficacy and safety of surgery versus fibrinolytic therapy in patients with prosthetic valve obstruction. Materials and Methods: We compared 15 patients of prosthetic valve thrombosis treated by surgical line of management and another 15 patients treated by thrombolysis. All patients were initially assessed by clinical evaluation and diagnosis confirmed by transthoracic and transesophageal two-dimensional echocardiography. Depending on hemodynamic stability, pannus, or thrombus on transesophageal echocardiography, the patients were assigned surgical or medical line of management. Results: Patients mortality rate was 40% in fibrinolytic group and 13.33% in surgical group. Recurrence was 40% in fibrinolytic group while there was no recurrence till date in surgery group. Complications were more in fibrinolytic group as opposed to surgery group patient. Conclusion: From our experience, we conclude that redo surgery is effective and definitive treatment, especially in patients with stable hemodynamic conditions.

  9. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  10. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    Science.gov (United States)

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  11. Intraoral Laser Welding (ILW in Implant Prosthetic Dentistry: Case Report

    Directory of Open Access Journals (Sweden)

    Carlo Fornaini

    2012-01-01

    Full Text Available The aim of this clinical study was to describe the possibility of using the Nd:YAG laser device utilized in the dental offices to weld metals intraorally. The authors, before applying this technique “in vivo” on human subjects, tested the “in vitro” metal welding efficacy of dental Nd:YAG device firstly by interferometry, SEM, and EDS and subsequently by thermal camera and thermocouples in order to record temperature changes during the welding process on bovine jaws. Four implants were inserted in the edentulous maxillary arch of a 67 years old male patient. Immediately after that, a bar previously made by the dental technician was intraorally welded to the abutments by Nd:YAG laser (Fidelis Plus III, Fotona, Slovenia with these parameters: 9.90 mJ, 1 Hz, 15 msec, 0.6 mm spot. Then the prosthesis was connected to the bar with four OT Caps. This clinical study, even if preliminary, suggests that laser welding technique may be intraorally used without side effects.

  12. Prosthetic management of an ocular defect

    Directory of Open Access Journals (Sweden)

    Siddesh Kumar Chintal

    2010-01-01

    Full Text Available The disfigurement associated with the loss of an eye can cause significant physical and emotional problems. Various treatment modalities are available, one of which is implants. Although implant has a superior outcome, it may not be advisable in all patients due to economic factors. The present article describes the prosthetic management of an ocular defect with a custom-made ocular prosthesis.

  13. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    functional magnetic resonance imaging (f- MRI ) was used to analyze the reciprocal adaptation between the human brain and the prosthetic hand by the...Schmidt PC. Influence of compacted hydrophobic and hydrophilic colloidal silicon dioxide on tableting properties of pharmaceutical excipients. Drug Dev...nanoparticles, and manganese nanoparticles) in magnetic resonance imaging ( MRI ) in the detection and staging of cancer [2]. 2.1 Iron Oxide

  14. Dynamic elasticity measurement for prosthetic socket design.

    Science.gov (United States)

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  15. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Impact of the "Guidelines for infection prevention in dentistry" (2006) by the Commission of Hospital Hygiene and Infection Prevention at the Robert Koch-Institute (KRINKO) on hygiene management in dental practices - analysis of a survey from 2009.

    Science.gov (United States)

    Hübner, Nils-Olaf; Handrup, Stephan; Meyer, Georg; Kramer, Axel

    2012-01-01

    To assess trends in hygiene management in dental practices in comparison to an earlier survey in 2002/2003 and to point out key aspects for future efforts. The infection prevention management of all dental practices in Greifswald (n=35) was determined by a questionnaire in a personal interview in 2008/2009. 26% of the dentists did not use sufficient personal protective equipment during the general examination of the patient. In conservative and prosthetic dentistry, 15% still did not use adequate measures and 9% did not even in surgical interventions. Vaccination coverage was clearly too low, as only 35% of dentists were vaccinated against influenza and coverage with other vaccinations was also quite low. 11% of the dentists did not perform a documented anamnesis and in 29% of the dental practices no appointment system for risk patients existed.There were significant deficiencies in the reprocessing of medical devices and in the equipment needed for reprocessing. The opportunity to participate in further training in this field was rejected by 23% of the dentists.In 10 dental practices, the colony count in the dental unit water-conducting system was five times higher than the limit. A contamination with P. aeruginosa was discovered in 4 practices. All units were renovated. Overall, both the hygiene management and hygiene equipment in the practices have improved considerably compared to the previous survey in 2002/2003. This demonstrates the positive effect of the KRINKO guidelines from 2006. However, the survey again showed relevant deficiences in the hygiene management of dental practices, which agrees with a Germany-wide online survey from 2009. While the study revealed persistent deficiencies in hygiene management, especially in reprocessing, it confirms that the KRINKO guidelines for dental practices from 2006 led to significant improvements in hygiene management. Doubts about the impact of the guidelines are not backed by evidence.

  17. Performance of Optimized Prosthetic Ankle Designs That Are Based on a Hydraulic Variable Displacement Actuator (VDA).

    Science.gov (United States)

    Gardiner, James; Bari, Abu Zeeshan; Kenney, Laurence; Twiste, Martin; Moser, David; Zahedi, Saeed; Howard, David

    2017-12-01

    Current energy storage and return prosthetic feet only marginally reduce the cost of amputee locomotion compared with basic solid ankle cushioned heel feet, possibly due to their lack of push-off at the end of stance. To the best of our knowledge, a prosthetic ankle that utilizes a hydraulic variable displacement actuator (VDA) to improve push-off performance has not previously been proposed. Therefore, here we report a design optimization and simulation feasibility study for a VDA-based prosthetic ankle. The proposed device stores the eccentric ankle work done from heel strike to maximum dorsiflexion in a hydraulic accumulator and then returns the stored energy to power push-off. Optimization was used to establish the best spring characteristic and gear ratio between ankle and VDA. The corresponding simulations show that, in level walking, normal push-off is achieved and, per gait cycle, the energy stored in the accumulator increases by 22% of the requirements for normal push-off. Although the results are promising, there are many unanswered questions and, for this approach to be a success, a new miniature, low-losses, and lightweight VDA would be required that is half the size of the smallest commercially available device.

  18. The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants.

    Science.gov (United States)

    De Pauw, Kevin; Cherelle, Pierre; Roelands, Bart; Lefeber, Dirk; Meeusen, Romain

    2018-04-01

    Evaluating the effectiveness of a novel prosthetic device during walking is an important step in product development. To investigate the efficacy of a novel quasi-passive ankle prosthetic device, Ankle Mimicking Prosthetic Foot 4.0, during walking at different speeds, using physiological determinants in transtibial and transfemoral amputees. Nonrandomized crossover design for amputees. Six able-bodied subjects, six unilateral transtibial amputees, and six unilateral transfemoral amputees underwent a 6-min walk test at normal speed, followed by series of 2-min walking at slow, normal, and fast speeds. The intensity of effort and subjective measures were determined. Amputees performed all walking tests on a treadmill with current and novel prostheses. Shapiro-Wilk normality tests and parametric and nonparametric tests were conducted (p 4.0 is a novel quasi-passive ankle prosthesis with state-of-the-art technological parts. Subjective measures show the importance of this technology, but the intensity of effort during walking still remains higher compared to current passive prostheses, especially in transfemoral amputees.

  19. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  20. Stiffness and hysteresis properties of some prosthetic feet

    OpenAIRE

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the hysteresis, which are the topics of this paper, are not properly prescribed, but could be adapted to improve the prosthetic walking performance. The shape is strongly related to the cosmetic appearance a...

  1. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    Science.gov (United States)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  2. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE

    Directory of Open Access Journals (Sweden)

    Cenk Sarı

    2016-03-01

    Full Text Available Transcatheter aortic valve implantation (TAVI was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE.

  3. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  4. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  5. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  6. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  7. Successful Management of Prosthetic Valve Brucella Endocarditis with Antibiotherapy Alone

    Directory of Open Access Journals (Sweden)

    José Pedro Fonseca

    2018-01-01

    Full Text Available Objectives: To report a case of mechanical aortic prosthesis Brucella endocarditis successfully treated with antibiotics alone. Materials and methods: We describe a clinical case and present a review of the literature. Results: A 60-year-old female farmer with a mechanical aortic prosthetic valve presented with low back pain and fever. She was diagnosed with prosthetic valve Brucella mellitensis endocarditis and was cured with antibiotic therapy alone. Few cases of successfully treated prosthetic valve Brucella endocarditis without surgery have been reported. Conclusion: Prosthetic valve Brucella endocarditis usually requires surgical valve replacement. However, selected patients may be successfully treated with antibiotic therapy alone.

  8. Possibility of magnetic resonance imaging application in teaching preclinical dentistry - endodontic and prosthetic treatment prognosis

    International Nuclear Information System (INIS)

    Tanasiewicz, T.

    2010-01-01

    Background. The necessary condition for successful both endodontic and prosthetic reconstruction treatment is the precise mapping of the shape of dental cavities. The aim of this work is an elaboration and verification of the possibility of using 3D Spin Echo MRI techniques in teaching preclinical dentistry both in endodontic and prosthetics specialty. Objectives. Author' aim was to obtain an elaboration and a verification, whether there exists a possibility to use, at the level of in vitro analysis, techniques of the Magnetic Resonance Imaging, which are based on the 3D sequence of the Spin Echo that may in the future find employment in the teaching of preclinical dentistry, clinical dental therapy and diagnostics within the scope of: a dimensional imaging of the inner topography of teeth and spatial structure of a chamber and root canals of teeth for the therapeutic and didactic aims; introduction of a nondestructive and a non-impressional method of reconstruction of the topography of the inner spaces of the human teeth for the purposes of the reconstructive dentistry. Material and Methods. 6 extracted molar teeth were used for measurements without additional preparation, after endodontic and prosthetic preparation. MR measurements were carried out on a 4.7 T research MRI system equipped with Maran DRX console. Results. Figures show 3D images of outer surface, inner space of the teeth before and after endodontic preparation and internal tooth fixation constructed using both classical methods (polymer mass impression) and non-impressional methods (MRI representation). The sizes of the presented volumes were calculated. Internal tooth volumes were determined before and after endodontic treatment; total tooth volumes were also measured. Research proceedings made it possible to compare the quality of internal tooth space after preparation for inner root canals fixations constructed using both classical methods and non-impressional MRI method. Conclusions. The results

  9. Long-term skeletal and dental changes in patients with cleft lip and palate after maxillary distraction: a report of three cases treated with a rigid external distraction device.

    Science.gov (United States)

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2005-04-01

    We examined long-term skeletal and dental changes in three patients with cleft lip and palate who underwent maxillary distraction using a rigid external distraction device. Two were children, and one was an adult. Changes in the overjet (OJ), overbite (OB), and positions of the anterior nasal spine (ANS), upper incisors (U1), pogonion (Pog), and lower incisors (L1) were measured on preoperative to 36 months postoperative lateral-cephalograms. In the adult, the positions of all examination points were relatively stable from 6 to 36 months postoperatively, and the OJ and OB were maintained at over 2 mm at 36 months. In the children, the positions of ANS and U1 changed inferiorly, Pog and L1 changed anteroinferiorly, and OJ and OB tended to decrease from 6 to 36 months postoperatively. Long-term skeletal and dental stability following maxillary distraction was relatively well maintained in the adult patient. In the children, the maxillomandibular growth was observed after maxillary distraction, but the mandibular overgrowth might have been inhibited by the correction of class III dentoskeletal deformity resulting from the maxillary distraction.

  10. Amputation rehabilitation and prosthetic restoration. From surgery to community reintegration.

    Science.gov (United States)

    Esquenazi, Alberto

    The purpose of this review is to summarize the literature related to the advances that have taken place in the management and rehabilitation care of limb amputation. Prostheses for the lower and upper limb amputee have changed greatly over the past several years, with advances in components, socket fabrication and fitting techniques, suspension systems and sources of power and electronic controls. Higher levels of limb amputation can now be fitted with functional prostheses, which allow more patients to achieve independent life styles. This is of particular importance for the multi-limb amputee. The rehabilitation of more traditional lower limb levels of amputation have also greatly benefited from the technological advances including energy storing feet, electronic control hydraulic knees, ankle rotators and shock absorbers to mention a few. For the upper limb amputee, myoelectric and proportional controlled terminal devices and elbow joints are now used routinely in some rehabilitation facilities. Experimental prosthetic fitting techniques and devices such as the use of osseo-implantation for suspension of the prosthesis, tension control hands or electromagnetic fluids for knee movement control will also be briefly discussed in this paper. It is possible to conclude from this review that many advances have occurred that have greatly impacted the functional outcomes of patients with limb amputation.

  11. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  12. Influence of shape and finishing on the corrosion of palladium-based dental alloys

    NARCIS (Netherlands)

    Milheiro, A.; Muris, J.; Kleverlaan, C.J.; Feilzer, A.J.

    2015-01-01

    PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were

  13. Dynamics of dental check-ups among the population

    Directory of Open Access Journals (Sweden)

    Karimova D.Y.

    2015-09-01

    of countries have not produced any free prosthetics. Conclusion. Reduced the number of patients who received pros-theses, especially for free. The most unfavorable situation is observed in the North Caucasus Federal District (-64.9%, mainly due to the Chechen Republic and the Republic of Dagestan, where the figure is zero. The current situation in the field of dental care, requires a differentiated approach and to adequately address problems from a regional perspective.

  14. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  15. Dental OCT

    Science.gov (United States)

    Wilder-Smith, Petra; Otis, Linda; Zhang, Jun; Chen, Zhongping

    This chapter describes the applications of OCT for imaging in vivo dental and oral tissue. The oral cavity is a diverse environment that includes oral mucosa, gingival tissues, teeth and their supporting structures. Because OCT can image both hard and soft tissues of the oral cavity at high resolution, it offers the unique capacity to identity dental disease before destructive changes have progressed. OCT images depict clinically important anatomical features such as the location of soft tissue attachments, morphological changes in gingival tissue, tooth decay, enamel thickness and decay, as well as the structural integrity of dental restorations. OCT imaging allows for earlier intervention than is possible with current diagnostic modalities.

  16. Prevention of Infection in Orthopedic Prosthetic Surgery.

    Science.gov (United States)

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  17. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  18. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  19. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  20. Prosthetic prescription in the Netherlands: An interview with clinical experts

    NARCIS (Netherlands)

    Van Der Linde, H.; Geertzen, J.H.B.; Hofstad, C.J.; Van Limbeek, Jacques; Postema, K.

    2004-01-01

    In the process of guideline development for prosthetic prescription in the Netherlands the authors made a study of the daily clinical practice of lower limb prosthetics. Besides the evidence-based knowledge from literature the more implicit knowledge from clinical experts is of importance for

  1. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    Directory of Open Access Journals (Sweden)

    Ge Shuzhi

    2011-03-01

    Full Text Available Abstract Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a varying the internal topology of the finger phalanx and (b varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a little, (b ring, and (c middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to

  2. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    Science.gov (United States)

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  3. Infant dental care (image)

    Science.gov (United States)

    ... sugar water. As the child grows, establishing proper dental hygiene will promote healthy teeth and gums which are essential to overall good health. Poor dental development, dental disease, and dental trauma can result ...

  4. Selective Laser Melting Technique of Co-Cr Dental Alloys: A Review of Structure and Properties and Comparative Analysis with Other Available Techniques.

    Science.gov (United States)

    Koutsoukis, Theodoros; Zinelis, Spiros; Eliades, George; Al-Wazzan, Khalid; Rifaiy, Mohammed Al; Al Jabbari, Youssef S

    2015-06-01

    The aim of this study was to review the effect of selective laser melting (SLM) procedure on the properties of dental structures made of Co-Cr alloys and to evaluate its quality and compare it to those produced by conventional casting and milling fabrication techniques. A computerized database search using PubMed and Scopus was conducted for peer-reviewed scientific research studies regarding the use of SLM in Co-Cr dental alloys with no restrictions for publication years. The search engines provided hundreds of results, and only 48 scientific research papers, case studies, or literature reviews were considered relevant for this review. The innovative manufacturing concept of SLM offers many advantages compared with casting and milling fabrication techniques. SLM provides different microstructure from casting and milling with minimal internal porosity and internal fitting, marginal adaptation, and comparable bond strength to porcelain. Mechanical and electrochemical properties of SLM structures are enhanced compared to cast, while clinical longevity of single-metal ceramic crowns is comparable to Au-Pt dental alloy. The SLM technique provides dental prosthetic restorations more quickly and less expensively without compromising their quality compared with restorations prepared by casting and milling techniques. The current SLM devices provide metallic restorations made of Co-Cr alloys for removable and fixed partial dentures without compromising the alloy or restoration properties at a fraction of the time and cost, showing great potential to replace the aforementioned fabrication techniques in the long term; however, further clinical studies are essential to increase the acceptance of this technology by the worldwide dental community. © 2015 by the American College of Prosthodontists.

  5. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  6. Resource-efficient proces chains to manufacture patient-specific prosthetic fingers

    Directory of Open Access Journals (Sweden)

    Hagedorn-Hansen, D.

    2016-05-01

    Full Text Available The high cost of quality prostheses, together with the lack of trained prosthetists, makes it challenging to obtain prosthetic devices in developing communities. Modern 3D digitising techniques and additive manufacturing (AM technologies are gaining popularity in the bio-medical industry and, in the case of prosthesis production, reduce the need for a trained prosthetist. The objective of this research was to develop a new resource-efficient process chain for the manufacturing of prosthetic fingers using additive manufacturing technologies, and to compare it with the traditional (Sculptor process chain. Fused deposition modelling (FDM, open-source FDM, 3-dimensional printing (3DP, and stereolithography (SLA were evaluated in terms of their costs, time, material usage, and aesthetic quality. The surface qualities produced with the different additive manufacturing technologies were also compared. The results showed that 3DP was the preferred technology and was the best candidate for the production of prosthesis in terms of cost, quality, and time for developing communities. SLA produced the highest aesthetic quality prosthesis, but was the most expensive. It was concluded that using the additive manufacturing technology process chain to produce prosthetic fingers is faster and more cost effective than the traditional method.

  7. Biologically inspired multi-layered synthetic skin for tactile feedback in prosthetic limbs.

    Science.gov (United States)

    Osborn, Luke; Nguyen, Harrison; Betthauser, Joseph; Kaliki, Rahul; Thakor, Nitish

    2016-08-01

    The human body offers a template for many state-of-the-art prosthetic devices and sensors. In this work, we present a novel, sensorized synthetic skin that mimics the natural multi-layered nature of mechanoreceptors found in healthy glabrous skin to provide tactile information. The multi-layered sensor is made up of flexible piezoresistive textiles that act as force sensitive resistors (FSRs) to convey tactile information, which are embedded within a silicone rubber to resemble the compliant nature of human skin. The top layer of the synthetic skin is capable of detecting small loads less than 5 N whereas the bottom sensing layer responds reliably to loads over 7 N. Finite element analysis (FEA) of a simplified human fingertip and the synthetic skin was performed. Results suggest similarities in behavior during loading. A natural tactile event is simulated by loading the synthetic skin on a prosthetic limb. Results show the sensors' ability to detect applied loads as well as the ability to simulate neural spiking activity based on the derivative and temporal differences of the sensor response. During the tactile loading, the top sensing layer responded 0.24 s faster than the bottom sensing layer. A synthetic biologically-inspired skin such as this will be useful for enhancing the functionality of prosthetic limbs through tactile feedback.

  8. Dental Calculus Arrest of Dental Caries

    OpenAIRE

    Keyes, Paul H.; Rams, Thomas E.

    2016-01-01

    Background An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human t...

  9. Oral health-related quality of life after prosthetic rehabilitation in patients with oral cancer: A longitudinal study with the Liverpool Oral Rehabilitation Questionnaire version 3 and Oral Health Impact Profile-14 questionnaire.

    Science.gov (United States)

    Dholam, K P; Chouksey, G C; Dugad, J

    2016-01-01

    Prosthodontic rehabilitation helps to improve the oral health-related quality of life (OHRQOL). The Liverpool Oral Rehabilitation Questionnaire (LORQ) and Oral Health Impact Profile (OHIP) are specific tools that measure OHRQOL. The primary objective of this study was to assess the impact of oral rehabilitation on patients' OHRQOL following treatment for cancer of oral cavity using LORQ version 3 (LORQv3) and OHIP-14 questionnaire. Secondary objectives were to identify issues specific to oral rehabilitation, patients compliance to prosthetic rehabilitation, the effect of radiation treatment on prosthetic rehabilitation, to achieve meaningful differences over a time before & after prosthetic intervention, to carryout and document specific patient-deprived problem. Seventy-five oral cancer patients were studied. Patients were asked to rate their experience of dental problems before fabrication of prosthesis and after 1 year using LORQv3 and OHIP-14. The responses were compared on Likert scale. Patients reported with extreme problems before rehabilitation. After 1 year of prosthetic rehabilitation, there was improvement noticed in all the domain of LORQv3 and OHIP-14. Complete compliance to the use of prosthetic appliances for 1 year study period was noted. In response to the question no. 40 (LORQv3), only 15 patients who belonged to the obturator group, brought to notice the problems which were not addressed in the LORQv3 questionnaire. The study showed that the oral cancer patients coped well and adapted to near normal oral status after prosthetic rehabilitation. This contributed to the improved overall health-related quality of life.

  10. Local signaling from a retinal prosthetic in a rodent retinitis pigmentosa model in vivo

    Science.gov (United States)

    Fransen, James W.; Pangeni, Gobinda; Pardue, Machelle T.; McCall, Maureen A.

    2014-08-01

    Objective. In clinical trials, retinitis pigmentosa patients implanted with a retinal prosthetic device show enhanced spatial vision, including the ability to read large text and navigate. New prosthetics aim to increase spatial resolution by decreasing pixel/electrode size and limiting current spread. To examine spatial resolution of a new prosthetic design, we characterized and compared two photovoltaic array (PVA) designs and their interaction with the retina after subretinal implantation in transgenic S334ter line 3 rats (Tg S334ter-3). Approach. PVAs were implanted subretinally at two stages of degeneration and assessed in vivo using extracellular recordings in the superior colliculus (SC). Several aspects of this interaction were evaluated by varying duration, irradiance and position of a near infrared laser focused on the PVA. These characteristics included: activation threshold, response linearity, SC signal topography and spatial localization. The major design difference between the two PVA designs is the inclusion of local current returns in the newer design. Main results. When tested in vivo, PVA-evoked response thresholds were independent of pixel/electrode size, but differ between the new and old PVA designs. Response thresholds were independent of implantation age and duration (⩽7.5 months). For both prosthesis designs, threshold intensities were within established safety limits. PVA-evoked responses require inner retina synaptic transmission and do not directly activate retinal ganglion cells. The new PVA design evokes local retinal activation, which is not found with the older PVA design that lacks local current returns. Significance. Our study provides in vivo evidence that prosthetics make functional contacts with the inner nuclear layer at several stages of degeneration. The new PVA design enhances local activation within the retina and SC. Together these results predict that the new design can potentially harness the inherent processing within

  11. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    Science.gov (United States)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  12. The influence of standards and clinical guidelines on prosthetic and orthotic service quality: a scoping review.

    Science.gov (United States)

    Sadeghi-Demneh, Ebrahim; Forghany, Saeed; Onmanee, Pornsuree; Trinler, Ursula; Dillon, Michael P; Baker, Richard

    2017-06-20

    Standards and guidelines are an integral part of prosthetic and orthotic service delivery in the developed world underpinned by an assumption that they lead to improved services. Implementing them has a cost, however, and that cost needs to be justified, particularly in resource-limited environments. This scoping review thus asks the question, "What is the evidence of the impact of standards and guidelines on service delivery outcomes in prosthetics and orthotics?" A structured search of three electronic databases (Medline, Scopus and Web of Science) followed by manual searching of title, abstract and full text, yielded 29 articles. Four categories of papers were identified: Descriptions and Commentaries (17 papers), Guideline Development (7), Guideline Testing (2) and Standards implementation (3). No articles were explicitly designed to assess the impact of standards and guidelines on service delivery outcomes in prosthetics and orthotics. Studies tended to be commentaries on or descriptions of guideline development, testing or implementation of standards. The literature is not sufficiently well developed to warrant the cost and effort of a systematic review. Future primary research should seek to demonstrate whether and how guidelines and standards improve the outcomes for people that require prostheses, orthoses and other assistive devices. Implications for Rehabilitation International Standards and Clinical Guidelines are now an integral part of clinical service provision in prosthetics and orthotics in the developed world. Complying with standards and guidelines has a cost and, particularly in resource-limited environments, it should be possible to justify this in terms of the resulting benefits. This scoping review concludes that there have been no previous studies designed to directly quantify the effects of implementing standards and guidelines on service delivery.

  13. Prosthetic Oral Rehabilitation of a Child With S-ECC: A Case Report with Histopathologic Analysis.

    Science.gov (United States)

    Tannure, P N; Moraes, G G; Borba, McU; Abrahão, A; Andrade, Mtrc; Fidalgo, Tks

    2015-01-01

    The aim of this case report is to describe the treatment planning of a young child with severe early childhood caries (S-ECC) as well as the prosthetic rehabilitation technique. A 3-year-old female child was referred to the pediatric dentistry clinic with the chief complaint of tooth pain, difficulty in eating and recurrent hospitalizations caused by dental infections. The mother reported intermittent episodes of fever and recurrent swelling of child's face. The girl presented angular cheilitis and was referred to a dietitian. The treatment plain consisted on a behavior changes in oral hygiene habits, exodontias of all primary teeth and oral rehabilitation with a prosthesis. The extracted teeth with periapical lesions were submitted to histopathologic analysis (hematoxilin and eosin staining) and revealed an inflammatory infiltrate. The aesthetic requirement of children with S-ECC has been a challenge to pediatric dentists. In the present case, the oral rehabilitation provided for the children better aesthetic, nutrition, phonation, and functional conditions.

  14. Prosthetic rehabilitation of a marginally resected mandibular arch with a metal reinforced telescopic overdenture.

    Science.gov (United States)

    Rohit, Raghavan; Prathith, Uthappa; Regish, K M; Rupesh, P L; Basavaraj, Salagundi; Padmanabhan, T V

    2014-09-01

    Success of the prosthesis after mandibular resection is related directly to the amount of the remaining bone and soft tissue present. The prognosis for mandibulectomy patients becomes less favorable as the size of the resection increases. Prosthetic rehabilitation for such patients is a challenge for clinicians. Without preprosthetic reconstructive surgery, denture fabrication for mandibulectomy patients becomes extremely difficult. Telescopic dentures is a modality of treatment consisting of an inner or primary telescopic coping which is permanently cemented to an abutment and an outer or secondary telescopic coping which is attached to the prosthesis. These copings protect the abutment from dental caries and thermal irritations and also provide retention and stabilization of the secondary coping. The secondary coping engages the primary copings to form a telescopic unit and it provides retention and stability to the prosthesis. This clinical report aims at utilizing the remaining natural teeth for a mandibular overdenture with telescopic coping.

  15. Oral manifestations and prosthetic rehabilitation in hereditary sensory and autonomic neuropathy (HSAN)type IV: a case report.

    Science.gov (United States)

    Ofluoglu, Duygu; Altin, Nazli; Yaman, Elif; Tuna İnce, Elif Bahar; Aytepe, Zeynep; Tanyeri, Hakki

    2016-01-01

    Hereditary sensory and autonomic neuropathies (HSAN) are rare genetic syndromes of unknown etiology. They are seen in early childhood and are categorized into six different types by their symptoms. HSAN type 4 demonstrates autosomal recessive transmission pattern, with such major characteristics as loss of sense of pain, self-mutilation, anhydrosis and mental retardation. Sympathetic innervations are deficient despite the existence of sweat glands. Sufferers are hypotonic without any tendon reflexes, and neuro-motor development is retarded. In some cases tactile sensation and vibration may be intact. Biting injuries due to lack of pain sensation cause laceration, ulceration and scarring of the tongue, lips and other parts of oral mucosa. Tooth luxation and severe dental attrition have been observed. This case report presents oral and dental findings, surgical treatments and prosthetic rehabilitation of an 11- year-old boy with HSAN type 4.

  16. ORAL MANIFESTATIONS AND PROSTHETIC REHABILITATION IN HEREDITARY SENSORY AND AUTONOMIC NEUROPATHY (HSANTYPE IV:A CASE REPORT*

    Directory of Open Access Journals (Sweden)

    Duygu OFLUOĞLU

    2016-04-01

    Full Text Available Hereditary sensory and autonomic neuropathies (HSAN are rare genetic syndromes of unknown etiology. They are seen in early childhood and are categorized into six different types by their symptoms. HSAN type 4 demonstrates autosomal recessive transmission pattern, with such major characteristics as loss of sense of pain, self-mutilation, anhydrosis and mental retardation. Sympathetic innervations are deficient despite the existence of sweat glands. Sufferers are hypotonic without any tendon reflexes, and neuro-motor development is retarded. In some cases tactile sensation and vibration may be intact. Biting injuries due to lack of pain sensation cause laceration, ulceration and scarring of the tongue, lips and other parts of oral mucosa. Tooth luxation and severe dental attrition have been observed. This case report presents oral and dental findings, surgical treatments and prosthetic rehabilitation of an 11- year-old boy with HSAN type 4.

  17. Getting signals into the brain: visual prosthetics through thalamic microstimulation.

    Science.gov (United States)

    Pezaris, John S; Eskandar, Emad N

    2009-07-01

    Common causes of blindness are diseases that affect the ocular structures, such as glaucoma, retinitis pigmentosa, and macular degeneration, rendering the eyes no longer sensitive to light. The visual pathway, however, as a predominantly central structure, is largely spared in these cases. It is thus widely thought that a device-based prosthetic approach to restoration of visual function will be effective and will enjoy similar success as cochlear implants have for restoration of auditory function. In this article the authors review the potential locations for stimulation electrode placement for visual prostheses, assessing the anatomical and functional advantages and disadvantages of each. Of particular interest to the neurosurgical community is placement of deep brain stimulating electrodes in thalamic structures that has shown substantial promise in an animal model. The theory of operation of visual prostheses is discussed, along with a review of the current state of knowledge. Finally, the visual prosthesis is proposed as a model for a general high-fidelity machine-brain interface.

  18. Microtomography evaluation of dental tissue wear surface induced by in vitro simulated chewing cycles on human and composite teeth

    Directory of Open Access Journals (Sweden)

    Rossella Bedini

    2012-01-01

    Full Text Available In this study a 3D microtomography display of tooth surfaces after in vitro dental wear tests has been obtained. Natural teeth have been compared with prosthetic teeth, manufactured by three different polyceramic composite materials. The prosthetic dental element samples, similar to molars, have been placed in opposition to human teeth extracted by paradontology diseases. After microtomography analysis, samples have been subjected to in vitro fatigue test cycles by servo-hydraulic mechanical testing machine. After the fatigue test, each sample has been subjected again to microtomography analysis to obtain volumetric value changes and dental wear surface images. Wear surface images were obtained by 3D reconstruction software and volumetric value changes were measured by CT analyser software. The aim of this work has been to show the potential of microtomography technique to display very clear and reliable wear surface images. Microtomography analysis methods to evaluate volumetric value changes have been used to quantify dental tissue and composite material wear.

  19. Clinical characteristics of an allergic reaction to a polyether dental impression material.

    Science.gov (United States)

    Rafael, Caroline Freitas; Liebermann, Anja

    2017-04-01

    Allergic and hypersensitivity reactions to dental impression materials may occur throughout dental treatment, with diverse manifestations from slight redness to severe pain and a burning mouth with total stomatitis. Patients are often unaware of these allergic reactions, which makes early identification of the cause almost impossible. In addition, symptoms usually begin after 24 hours and mostly in patients with a preexisting history of allergic responses. This report describes a patient with a suspected allergic reaction to a polyether dental impression material during prosthetic rehabilitation associated with a mandibular telescopic denture. Although instances of such occurrence are rare, clinicians need to be aware of these symptoms and select materials carefully for patients with a history of allergy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  1. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  2. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    Science.gov (United States)

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  3. Trends in prosthetic biomaterials in implant dentistry

    Directory of Open Access Journals (Sweden)

    Saranjit Singh Bhasin

    2015-01-01

    Full Text Available The most important criterion for the success of dental implants is the selection of a suitable implant biomaterial. To improve the biologic performance of an implant, it is necessary to select a material that does not elicit any negative biological response and at the same time maintains adequate function. It is mandatory for a dentist to have a comprehensive knowledge of various biomaterials used for dental implants. The material of choice for fabrication of the dental implant till date is titanium. With the advancements in the field of implants, zirconia seems to be propitious in the future. However, more advanced in vitro and in vivo studies are required before reaching any such conclusion. To increase the success of zirconia implants, care should be taken to reduce the incidence of mechanical failures. Such failures can be taken care of by having a thorough technical knowledge of implant designing and manufacturing defects. This article attempts to compare the advantages and disadvantages of various dental implant biomaterials. Focus is placed on the recent advances in this field with the recently introduced zirconia and its comparison to conventional titanium.

  4. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    Science.gov (United States)

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  5. Design for a three-fingered hand. [robotic and prosthetic applications

    Science.gov (United States)

    Crossley, F. R. E.

    1977-01-01

    This paper describes the construction of a prototype mechanical hand or 'end effector' for use on a remotely controlled robot, but with possible application as a prosthetic device. An analysis of hand motions is reported, from which it is concluded that the two most important manipulations (apart from grasps) are to be able to pick up a tool and draw it into a nested grip against the palm, and to be able to hold a pistol-grip tool such as an electric drill and pull the trigger. One of our models was tested and found capable of both these operations.

  6. Impact of depressive symptoms on prosthetic status--results of the study of health in Pomerania (SHIP).

    Science.gov (United States)

    Samietz, Stefanie A; Kindler, Stefan; Schwahn, Christian; Polzer, Ines; Hoffmann, Wolfgang; Kocher, Thomas; Grabe, Hans Jörgen; Mundt, Torsten; Biffar, Reiner

    2013-05-01

    Previous investigations have confirmed that every fifth dental patient suffers from clinically significant depressive symptoms. However, the putative impact of depressive symptoms on the prosthetic status has not been addressed in these studies. The objective of this study was to investigate the association between depressive symptoms and prosthetic status based on data from the Study of Health in Pomerania (SHIP-0). Data from 2,135 participants aged 30 to 59 years were analyzed. A classification (six classes regarding the number and position of missing teeth per jaw) was used to identify the degree of prosthetic status (no/suboptimal/optimal tooth replacement). The presence of depressive symptoms was assessed with a modified version of von Zerssen's complaints scale. Screening for lifetime diagnoses of mental disorders was performed with the Composite International Diagnostic-Screener (CID-S). Multivariable logistic regressions including several confounders were calculated. A significant protective dose-response effect of depressive symptoms on prosthetic status was found only in men for the lower jaw [0-1 depressive symptoms: odds ratio (OR) = 3.84, 95 % confidence interval (CI, 1.65-8.92), p < 0.01; 2-3: OR = 2.87 (CI, 1.22-6.74), p < 0.05; reference, ≥8; adjusted for age, school education, smoking status, household income, marital status, living without a partner, risky alcohol consumption, obesity, diabetes, and physical activity]. There was no such association in women or for the upper jaw. The analyses using the CID-S confirmed these results. In the lower jaw, men with depressive symptoms had a better prosthetic status than men without depressive symptoms suggesting a higher level of concern regarding their personal health. If dentists might have an opportunity to identify men with depressive symptoms they can provide a wide range of treatment options that may enhance patients' self-esteem and contribute to the patient' well-being. Furthermore, depressive

  7. Dental caries

    DEFF Research Database (Denmark)

    Pitts, Nigel B; Zero, Domenick T; Marsh, Phil D

    2017-01-01

    Dental caries is a biofilm-mediated, sugar-driven, multifactorial, dynamic disease that results in the phasic demineralization and remineralization of dental hard tissues. Caries can occur throughout life, both in primary and permanent dentitions, and can damage the tooth crown and, in later life......, exposed root surfaces. The balance between pathological and protective factors influences the initiation and progression of caries. This interplay between factors underpins the classification of individuals and groups into caries risk categories, allowing an increasingly tailored approach to care. Dental...... caries is an unevenly distributed, preventable disease with considerable economic and quality-of-life burdens. The daily use of fluoride toothpaste is seen as the main reason for the overall decline of caries worldwide over recent decades. This Primer aims to provide a global overview of caries...

  8. Prosthetic joint infection caused by Trueperella bernardiae.

    Science.gov (United States)

    Gilarranz, Raul; Chamizo, Francisco; Horcajada, Iballa; Bordes-Benítez, Ana

    2016-09-01

    Trueperella bernardiae is a Gram-positive coryneform bacilli which role as human pathogen is unknown because it has been usually considered a contaminant. Furthermore its identification by biochemical test was difficult. We describe a prosthetic joint infection in a women who years ago underwent a total knee replacement with superinfection and necrosis of the patellar tendon as major complications. In the sample of synovial fluid collected grew a gram-positive bacilli which was identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) as T. bernardiae. The patient was treated with ciprofloxacin and currently preserves the prosthesis without signs of infection. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Dental Calculus Arrest of Dental Caries.

    Science.gov (United States)

    Keyes, Paul H; Rams, Thomas E

    An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human teeth for the presence and location of dental caries, dental calculus, and dental plaque biofilms. A total of 1,200 teeth were preserved in 10% buffered formal saline, and viewed while moist by a single experienced examiner using a research stereomicroscope at 15-25× magnification. Representative teeth were sectioned and photographed, and their dental plaque biofilms subjected to gram-stain examination with light microscopy at 100× magnification. Dental calculus was observed on 1,140 (95%) of the extracted human teeth, and no dental carious lesions were found underlying dental calculus-covered surfaces on 1,139 of these teeth. However, dental calculus arrest of dental caries was found on one (0.54%) of 187 evaluated teeth that presented with unrestored proximal enamel caries. On the distal surface of a maxillary premolar tooth, dental calculus mineralization filled the outer surface cavitation of an incipient dental caries lesion. The dental calculus-covered carious lesion extended only slightly into enamel, and exhibited a brown pigmentation characteristic of inactive or arrested dental caries. In contrast, the tooth's mesial surface, without a superficial layer of dental calculus, had a large carious lesion going through enamel and deep into dentin. These observations further document the potential protective effects of dental calculus mineralization against dental caries.

  10. Dental Calculus Arrest of Dental Caries

    Science.gov (United States)

    Keyes, Paul H.; Rams, Thomas E.

    2016-01-01

    Background An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human teeth for the presence and location of dental caries, dental calculus, and dental plaque biofilms. Materials and methods A total of 1,200 teeth were preserved in 10% buffered formal saline, and viewed while moist by a single experienced examiner using a research stereomicroscope at 15-25× magnification. Representative teeth were sectioned and photographed, and their dental plaque biofilms subjected to gram-stain examination with light microscopy at 100× magnification. Results Dental calculus was observed on 1,140 (95%) of the extracted human teeth, and no dental carious lesions were found underlying dental calculus-covered surfaces on 1,139 of these teeth. However, dental calculus arrest of dental caries was found on one (0.54%) of 187 evaluated teeth that presented with unrestored proximal enamel caries. On the distal surface of a maxillary premolar tooth, dental calculus mineralization filled the outer surface cavitation of an incipient dental caries lesion. The dental calculus-covered carious lesion extended only slightly into enamel, and exhibited a brown pigmentation characteristic of inactive or arrested dental caries. In contrast, the tooth's mesial surface, without a superficial layer of dental calculus, had a large carious lesion going through enamel and deep into dentin. Conclusions These observations further document the potential protective effects of dental calculus mineralization against dental caries. PMID:27446993

  11. Prosthetic rehabilitation of oral submucous fibrosis patients: A systematic review of published case reports and case series.

    Directory of Open Access Journals (Sweden)

    Shankargouda Patil

    Full Text Available Oral submucous fibrosis (OSF is an insidious chronic condition characterized by restricted mouth opening. Prosthetic rehabilitation is challenging for OSF patients as obtaining a good impression requires adequate mouth opening. The aim of the present review is to systematically present the data from case reports published in the English-language literature.A comprehensive search of the literature databases (PubMed, Medline, SCOPUS, Web of Science and Google Scholar along with the references of published articles on prosthetic rehabilitation in OSF patients published to date was conducted. Keywords included a combination of 'Oral submucous fibrosis', 'prosthesis', 'dentures' and/or 'restricted mouth opening'. Citations from selected references and bibliographic linkages taken from similar cases were included in this review. The inclusion criteria selected for case reports on prosthetic rehabilitation in OSF patients, and cases of restricted mouth opening due to causes other than OSF were excluded from the study.A total of 21 cases were identified and analysed from 17 papers published in the English-language literature. Of these, 9 cases employed the sectional denture technique, 4 cases emphasized the need-based treatment approach in which conventional methods were modified, and 4 cases used mouth exercising devices. Finally, 1 case each involved, flexible denture, oral screen prosthesis, oral stents, surgery in conjunction with dentures.Prosthetic rehabilitation in OSF patients is a multifaceted approach and should be patient specific, although sectional dentures have achieved the best results.

  12. Prosthetic rehabilitation of oral submucous fibrosis patients: A systematic review of published case reports and case series.

    Science.gov (United States)

    Patil, Shankargouda; Sarode, Sachin Chakradhar; Sarode, Gargi S; Bhandi, Shilpa; Awan, Kamran Habib; Ferrari, Marco

    2017-01-01

    Oral submucous fibrosis (OSF) is an insidious chronic condition characterized by restricted mouth opening. Prosthetic rehabilitation is challenging for OSF patients as obtaining a good impression requires adequate mouth opening. The aim of the present review is to systematically present the data from case reports published in the English-language literature. A comprehensive search of the literature databases (PubMed, Medline, SCOPUS, Web of Science and Google Scholar) along with the references of published articles on prosthetic rehabilitation in OSF patients published to date was conducted. Keywords included a combination of 'Oral submucous fibrosis', 'prosthesis', 'dentures' and/or 'restricted mouth opening'. Citations from selected references and bibliographic linkages taken from similar cases were included in this review. The inclusion criteria selected for case reports on prosthetic rehabilitation in OSF patients, and cases of restricted mouth opening due to causes other than OSF were excluded from the study. A total of 21 cases were identified and analysed from 17 papers published in the English-language literature. Of these, 9 cases employed the sectional denture technique, 4 cases emphasized the need-based treatment approach in which conventional methods were modified, and 4 cases used mouth exercising devices. Finally, 1 case each involved, flexible denture, oral screen prosthesis, oral stents, surgery in conjunction with dentures. Prosthetic rehabilitation in OSF patients is a multifaceted approach and should be patient specific, although sectional dentures have achieved the best results.

  13. Swing Phase Control of Semi-Active Prosthetic Knee Using Neural Network Predictive Control With Particle Swarm Optimization.

    Science.gov (United States)

    Ekkachai, Kittipong; Nilkhamhang, Itthisek

    2016-11-01

    In recent years, intelligent prosthetic knees have been developed that enable amputees to walk as normally as possible when compared to healthy subjects. Although semi-active prosthetic knees utilizing magnetorheological (MR) dampers offer several advantages, they lack the ability to generate active force that is required during some states of a normal gait cycle. This prevents semi-active knees from achieving the same level of performance as active devices. In this work, a new control algorithm for a semi-active prosthetic knee during the swing phase is proposed to reduce this gap. The controller uses neural network predictive control and particle swarm optimization to calculate suitable command signals. Simulation results using a double pendulum model show that the generated knee trajectory of the proposed controller is more similar to the normal gait than previous open-loop controllers at various ambulation speeds. Moreover, the investigation shows that the algorithm can be calculated in real time by an embedded system, allowing for easy implementation on real prosthetic knees.

  14. 78 FR 16632 - Medicare Program; Part B Inpatient Billing in Hospitals

    Science.gov (United States)

    2013-03-18

    ... other devices used for reduction of fractures and dislocations. Prosthetic devices (other than dental... rehabilitation facilities (IRFs), CAHs, children's hospitals, cancer hospitals, and Maryland waiver hospitals. We...

  15. Chronological Age as Factor Influencing the Dental Implant Osseointegration in the Jaw Bone

    Directory of Open Access Journals (Sweden)

    Jan Papež

    2018-04-01

    Full Text Available The objectives of this study were to evaluate osseointegration of dental implant in the jaw bone in the young and elderly population and comparing the results to assess indicators and risk factors as age for the success or failure of dental implants. A retrospective study of 107 implants (Impladent, LASAK, Czech Republic was prepared. The patients at implants surgery were divided in three groups. The patients were followed-up for a 7-year period. We evaluated osseointegration from long term point of view as a change of marginal bone levels close to dental implant. Marginal bone levels were recorded and analysed with regard to different patient- and implant-related factors. An influence of chronological age on change of marginal bone levels during 6-year retrospective study vas evaluated. The study examined 47 patient charts and 107 implants from the Second Faculty of Medicine, Charles University and University Hospital Motol. We proved that young healthy patients with long bridges or Branemarks have the same progression of marginal bone levels changes. The chronological age hasn’t therefore direct influence on the osseointegration from long term point of view. But we found that the length of dental suprastrucure-prosthetic construction negatively influences marginal bone changes, though these results weren’t statistically significant. More extensive dental implant suprastrucure undergoes smaller osseointegration. On the other hand the length of dental suprastrucure (prosthetic construction negatively influences dental osseointegration in both groups of patient.

  16. Computational biomechanics of bone's responses to dental prostheses - osseointegration, remodeling and resorption

    International Nuclear Information System (INIS)

    Li Wei; Rungsiyakull, Chaiy; Field, Clarice; Lin, Daniel; Zhang Leo; Li Qing; Swain, Michael

    2010-01-01

    Clinical and experimental studies showed that human bone has the ability to remodel itself to better adapt to its biomechanical environment by changing both its material properties and geometry. As a consequence of the rapid development and extensive applications of major dental restorations such as implantation and fixed partial denture (FPD), the effect of bone remodeling on the success of a dental restorative surgery is becoming critical for prosthetic design and pre-surgical assessment. This paper aims to provide a computational biomechanics framework to address dental bone's responses as a result of dental restoration. It explored three important issues of resorption, apposition and osseointegration in terms of remodeling simulation. The published remodeling data in long bones were regulated to drive the computational remodeling prediction for the dental bones by correlating the results to clinical data. It is anticipated that the study will provide a more predictive model of dental bone response and help develop a new design methodology for patient-specific dental prosthetic restoration.

  17. The Historical Evolution of Dental Impression Materials.

    Science.gov (United States)

    Papadiochos, Ioannis; Papadiochou, Sofia; Emmanouil, Ioannis

    The concept of impression making process in dentistry began in the mid 1800s. Dentists realized that the construction of a prosthetic restoration required both a detailed capture of the oral tissues along with stone cast fabrications. To accomplish these goals, impression materials were essential. Beeswax represents the first impression material, while important bechmarks during the historical evolution of dental impression materials are considered to be the introduction of dental trays in the early 1800s and the invention of the gutta-percha, thermoplastic resins and plaster of Paris. The double (corrective) impression technique, along with the functional impression concept that was established after mid 1800s, are also identified as pivotal innovations. During the 20th century, the advances in material development slowed significantly since the majority of the current impression materials had already been invented. However, the introduction of elastomeric impression materials in the field of prosthodontics that offered the advantages of accuracy and dimensional stability substantially upgraded both the impression accuracy and the quality of the final restoration. Presently, the dental practitioner has access to a variety of impression materials and should be aware of their properties, indications and limitations as well. Futhermore, while continuous attempts are being made to enhance these materials, the ideal impression material has yet to be developed. The purpose of this article was to provide a comprehensive review about the historical development of impression dental materials. Copyright American Academy of the History of Dentistry.

  18. Dental expression and role in palliative treatment

    Directory of Open Access Journals (Sweden)

    Rajiv Saini

    2009-01-01

    Full Text Available World Health Organization defines palliative care as the active total care of patients whose disease is not responding to curative treatment. Palliative care for the terminally ill is based on a multidimensional approach to provide whole-person comfort care while maintaining optimal function; dental care plays an important role in this multidisciplinary approach. The aim of the present study is to review significance of dentist′s role to determine whether mouth care was effectively assessed and implemented in the palliative care setting. The oral problems experienced by the hospice head and neck patient clearly affect the quality of his or her remaining life. Dentist plays an essential role in palliative care by the maintenance of oral hygiene; dental examination may identify and cure opportunistic infections and dental disease like caries, periodontal disease, oral mucosal problems or prosthetic requirement. Oral care may reduce not only the microbial load of the mouth but the risk for pain and oral infection as well. This multidisciplinary approach to palliative care, including a dentist, may reduce the oral debilities that influence the patient′s ability to speak, eat or swallow. This review highlighted that without effective assessment of the mouth, the appropriate implementation of care will not be delivered. Palliative dental care has been fundamental in management of patients with active, progressive, far-advanced disease in which the oral cavity has been compromised either by the disease directly or by its treatment; the focus of care is quality of life.

  19. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  20. Implant Utilization and Time to Prosthetic Rehabilitation in Conventional and Advanced Fibular Free Flap Reconstruction of the Maxilla and Mandible.

    Science.gov (United States)

    Chuka, Richelle; Abdullah, Wael; Rieger, Jana; Nayar, Suresh; Seikaly, Hadi; Osswald, Martin; Wolfaardt, Johan

    Precisely designed jaw reconstruction rehabilitation (JRR) is important to the integrity of the jaw structure and oral functions. Advanced three-dimensional (3D) digital surgical design and simulation (SDS) techniques have the potential to reduce time to reconstructive and dental treatment completion, thereby promoting early functional oral rehabilitation. This study investigated the use of SDS in JRR procedures. A retrospective chart review was conducted on adult head and neck tumor (HNT) participants who completed JRR treatment with a fibular free flap (FFF) reconstruction. Two treatment approaches, advanced 3D SDS technique (with-SDS) and conventional, nondigitally planned technique (without-SDS), included the use of osseointegrated implants. Data were collected from adult patients treated between January 2000 and March 2014 at the Institute for Reconstructive Sciences in Medicine (iRSM). Participants were excluded if they underwent a bone-containing augmentation to the FFF reconstruction. The without-SDS group underwent a conventional, nonguided FFF reconstruction followed by nonguided implant placement. The with-SDS group underwent a guided FFF reconstruction with guided implant placement during the reconstructive surgery. The outcome measures included implant utilization (ratio of implants placed to connected) and time to prosthetic connection after FFF reconstruction. Mann-Whitney U test was used to analyze the data. The digital SDS technique (with-SDS) group completed prosthetic treatment with a significantly higher utilization of implants as well as a significantly shorter time to prosthetic delivery. SDS allows an interdisciplinary treatment team to work together to create a virtual plan that leads to greater efficiency in patient treatment time and utilization of dental implants.

  1. Dental Abnormalities in Pituitary Dwarfism: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Franco Ferrante

    2017-01-01

    Full Text Available Hypopituitarism is a disorder caused by a reduced level of trophic hormones that may be consequent on different destructive processes. The clinical manifestations depend on the type of hormone involved. A deficiency of growth hormone (GH in children causes the lack of growth known as pituitary dwarfism. The case is reported of a patient with pituitary dwarfism, multiple dental anomalies, functional prosthetic problems, and a revision of the literature. She was subjected to prosthetic rehabilitation without surgical intervention, using zirconium substructures, thus eliminating the potential complications that may require trauma surgery. The therapeutic approach adopted led to excellent results and restored an aesthetic smile.

  2. 21 CFR 872.1740 - Caries detection device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Caries detection device. 872.1740 Section 872.1740...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification. The caries detection device is a device intended to show the existence of decay in a patient's tooth...

  3. Fifteen years of follow-up of a removable prosthetic design to maintain two remaining molars in a patient with mandibular reconstruction

    Directory of Open Access Journals (Sweden)

    Ming-Lun Hsu

    2012-06-01

    Full Text Available This clinical report describes a long-term prosthetic solution for a patient who had undergone mandibular reconstruction with a fibular graft, leaving only two right molars. The only retention device for the removable prosthesis design included a telescoping system with an O-ring application, but without fibula graft involvement. This prosthesis design was motivated by the altered bony and muscular architecture resulting in an increased maxillomandibular space and thick soft tissue in the denture-bearing area. This case demonstrates that appropriate denture design, consistent recall maintenance, and oral hygiene motivation minimized periodontal destruction and maximized prosthetic use for the patient despite the unfavorable loading conditions.

  4. Analysis of Vector Models in Quantification of Artifacts Produced by Standard Prosthetic Inlays in Cone-Beam Computed Tomography (CBCT – a Preliminary Study

    Directory of Open Access Journals (Sweden)

    Ingrid Różyło-Kalinowska

    2014-11-01

    Full Text Available Cone-beam computed tomography (CBCT is a relatively new, but highly efficient imaging method applied first in dentistry in 1998. However, the quality of the obtained slices depends among other things on artifacts generated by dental restorations as well as orthodontic and prosthetic appliances. The aim of the study was to quantify the artifacts produced by standard prosthetic inlays in CBCT images. The material consisted of 17 standard prosthetic inlays mounted in dental roots embedded in resin. The samples were examined by means of a large field of view CBCT unit, Galileos (Sirona, Germany, at 85 kV and 14 mAs. The analysis was performed using Able 3DDoctor software for data in the CT raster space as well as by means of Materialise Magics software for generated vector models (STL. The masks generated in the raster space included the area of the inlays together with image artifacts. The region of interest (ROI of the raster space is a set of voxels from a selected range of Hounsfield units (109-3071. Ceramic inlay with zirconium dioxide (Cera Post as well as epoxy resin inlay including silica fibers enriched with zirconium (Easy Post produced the most intense artifacts. The smallest image distortions were created by titanium inlays, both passive (Harald Nordin and active (Flexi Flange. Inlays containing zirconium generated the strongest artifacts, thus leading to the greatest distortions in the CBCT images. Carbon fiber inlay did not considerably affect the image quality.

  5. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  6. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  7. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  8. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  9. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  10. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  11. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  12. Ceramics in Restorative and Prosthetic DENTISTRY1

    Science.gov (United States)

    Kelly, J. Robert

    1997-08-01

    This review is intended to provide the ceramic engineer with information about the history and current use of ceramics in dentistry, contemporary research topics, and potential research agenda. Background material includes intra-oral design considerations, descriptions of ceramic dental components, and the origin, composition, and microstructure of current dental ceramics. Attention is paid to efforts involving net-shape processing, machining as a forming method, and the analysis of clinical failure. A rationale is presented for the further development of all-ceramic restorative systems. Current research topics receiving attention include microstructure/processing/property relationships, clinical failure mechanisms and in vitro testing, wear damage and wear testing, surface treatments, and microstructural modifications. The status of the field is critically reviewed with an eye toward future work. Significant improvements seem possible in the clinical use of ceramics based on engineering solutions derived from the study of clinically failed restorations, on the incorporation of higher levels of "biomimicry" in new systems, and on the synergistic developments in dental cements and adhesive dentin bonding.

  13. Smartphones and dental trauma: the current availability of apps for managing traumatic dental injuries.

    Science.gov (United States)

    Djemal, Serpil; Singh, Parmjit

    2016-02-01

    There is a general consensus regarding the lack of awareness regarding the emergency management of traumatic dental injuries amongst laypersons and dental professionals. This article aims to provide an overview of the apps available for traumatic dental injuries using smartphones. These apps may serve as a gateway for raising awareness of traumatic dental injuries. Three smartphone devices were used to access their respective app stores (Nokia Lumia 635 with Windows Phone OS 8.1; iPhone 5 with iOS 8.1; Samsung Galaxy Ace II with Android OS v2.3.6 Gingerbread). Nine phrases were searched: broken tooth/teeth; chipped tooth/teeth; dental emergency; dental injury; dental trauma; fractured tooth/teeth; knocked-out tooth/teeth; tooth/teeth injury; and tooth/teeth trauma. Seven apps for the Android and one app for the Apple operating system were relevant. The only Apple iOS app retrieved (Dental Trauma) was also found for the Android OS (Dental Trauma First Aid) and had the endorsement of the International Association of Dental Traumatology. AcciDent was the only app dedicated to traumatic dental injuries targeted solely towards dental professionals. Five other apps (Chipped Tooth Solution, Dental Crown Repair, Fixing Cracked Tooth, Repairing the Front Tooth and Solution to Broken Tooth) appeared to come from the same source (KBES). No traumatic dental injury apps were found for the Windows Phone OS. There are apps available for both patients and dentists that range in quality and on the whole lack real-life photographs. Future apps should continue to provide good quality, evidence-based and validated material. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  15. Ergonomics in dental pratice

    Directory of Open Access Journals (Sweden)

    Lucas Quaresemin de Oliveira

    2017-08-01

    Full Text Available The application of ergonomics is critical so that you can get a suitable working environment for professional, it is safe, healthy and comfortable. The objective was to identify whether the dental students followed the principles of ergonomics during clinical visits, evaluating, through photographs, compliance with ergonomic principles applied in dental practice, and finally identify the most affected sites by RSI / WMSDs of students enrolled in the dental clinic of the Faculdade IMED. Snapshots were made and only considered the position of the student operator, the same taken by the researcher using the mobile device. For each clinical procedure were taken two photographs in hidden angles to the student operator so that it did not change its ergonomic position to be observed. After obtaining the photos, they were evaluated and classified in scores from 0 to 3 according to the adequacy of the work placement, and then inserted into Excel and later in a database (SPSS 15.0. The following work is a cross-sectional, observational study, they were conducted in dental clinics IMED college. Among the 66 respondents, 14 were male and 52 female. It was found that 57 (86,3% reported feeling pain somewhere in the body, being the most affected sites neck (36.4%, and consecutively lower back (30.3% and higher than the back (27.3%. The results of the 63 procedures performed by the photographic shots were classified as “inadequate” in 49 procedures, “partially adequate” in 12 and “impossible to evaluate” in 2 procedures. The research results have shown a high prevalence of musculoskeletal pain and do not follow the ergonomic principles, emphasizing the need for more attention to ergonomics of the students.

  16. Esthetic management of anterior dental anomalies: A clinical case.

    Science.gov (United States)

    Chafaie, Amir

    2016-09-01

    Many types of dental abnormality can be observed in the anterior sectors, where they can cause genuine esthetic problems for our patients. While conventional prosthetic treatments offer the best solutions in terms of esthetic result and durability, they involve the sacrifice of significant quantities of mineralized dental material and cannot be undertaken before the periodontal tissues are mature. Other less invasive alternatives should be envisaged as transitional, or sometimes even permanent, solutions for the management of these anomalies in children and adolescents. This article discusses these options and presents a clinical case where composite resin veneers and microabrasion of the enamel were used to treat dental agenesis and enamel dysplasia. Copyright © 2016 CEO. Published by Elsevier Masson SAS. All rights reserved.

  17. Preparation of an Adhesive in Emulsion for Maxillofacial Prosthetic

    Directory of Open Access Journals (Sweden)

    Joaquín Palacios-Alquisira

    2010-10-01

    Full Text Available Maxillofacial prostheses is a dental medicine specialty aimed at restoring anatomical facial defects caused by cancer, trauma or congenital malformations through an artificial device, which is commonly attached to the skin with the help of an adhesive. The purpose of our research was to develop a pressure-sensitive adhesive (PSA based on acrylic monomers, characterizing and determining its drying kinetics, that is to say the time it takes to lose 50 to 90% of its moisture. The adhesive synthesis was realized by means of emulsion polymerization; the composition of formulations was: (AA‑MMA‑EA and (AA‑MMA‑2EHA with different molar ratios. The formulation based on (AA‑MMA‑2EHA with 50 w% of solids, presented good adhesive properties such as tack, bond strength, and short drying time. We propose this formulation as a PSA, because it offers an alternative for systemically compromised patients, by less irritation compared to organic solvent-based adhesives.

  18. The Persian version of satisfaction assessment module of Orthotics and Prosthetics Users' Survey.

    Science.gov (United States)

    Hadadi, Mohammad; Ghoseiri, Kamiar; Fardipour, Shima; Kashani, Reza Vahab; Asadi, Farnoosh; Asghari, Azizeh

    2016-01-01

    Orthotics and Prosthetics User's Survey (OPUS) was developed to measure patient satisfaction in Prosthetic and Orthotic (P&O) field. To translate the satisfaction assessment module of OPUS (OPUS-SM) into Persian language (Persian OPUS-SM) and investigate its psychometric properties. For cross-cultural adaptation of the OPUS-SM, the guideline suggested by the World Health Organization was recruited. A sample of 116 Persian-speaking people who received P&O devices and services, participated in this study. During the first session, participants filled out the Persian OPUS-SM and the Visual Analog Scale (VAS) regarding their satisfaction from delivered devices and services. Drawing from the above sample of 116 participants, 41 participants retook the Persian OPUS-SM 5-7 days after their first time. The results of the first and second administration sessions were analyzed to assess internal consistency, test-retest reliability, item-subscale correlation, minimal detectable change, floor and ceiling effects, criterion validity, and dimensionality of the Persian OPUS-SM. The Cronbach's alphas of the Persian OPUS-SM were 0.71 and 0.89 for device and service satisfaction subscales, respectively. The intraclass correlation coefficients were 0.76 and 0.90 for device and service satisfaction subscales, respectively. The SEM and MDC for device satisfaction were 6.21 and ±17.21, respectively. The SEM and MDC for service satisfaction were 2.25 and ±6.22, respectively. There was a strong correlation between VAS and satisfaction subscales of the Persian OPUS-SM. Dimensionality assessment revealed that Persian OPUS-SM is a unidimensional measure. The adapted and translated Persian OPUS-SM is a reliable and validated measure. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The establishment of the Croatian Dental Crops: the front-line experience of a dentist volunteer.

    Science.gov (United States)

    Jelaca-Bagić, S; Sipina, J; Visković, R; Cakarun, Z; Vlatković, I; Biloglav, D

    1997-01-01

    The establishment of the first dental office of the Croatian Dental Corps (CDC) in the city of Zadar represented at the same time the beginning of the CDC. This article describes the front-line experience of a dentist who volunteered to provide basic medical help, which eventually laid the groundwork for providing general dental care and establishing the first CDC dental office. The office was opened on December 16, 1991, and provided general dental care except prosthetics. Although faced with numerous problems and extremely difficult conditions, the office staff completed 1,913 initial and 1,157 control checkups and performed 4,002 services by treating 12 to 16 patients per day. The main causes for emergencies were caries (59%) and endodontic complications (28%). This variety of services in the proximity of the front line is considered extensive even for advanced medical corps of modern armies.

  20. Clareamento Dental

    OpenAIRE

    Sossai, Najara; Universidade Paranaense - UNIPAR; Verdinelli, Ellen Carla; Universidade Paranaense - UNIPAR; Bassegio, Wagner; Universidade Paranaense - UNIPAR

    2011-01-01

    O clareamento dental já é utilizado há bastante tempo na Odontologia e atualmente é um dos tratamentos odontológicos mais solicitados para obtenção de um sorriso mais estético. Classificado em clareamento caseiro e/ou de consultório, ambas as técnicas são motivo de polêmica quanto aos seus benefícios, riscos, limitações e efeito clareador, bem como sobre qual é a melhor técnica existente para a promoção de um clareamento dental eficaz e seguro. Neste contexto, o presente estudo tem por objeti...

  1. Analytical Study of Active Prosthetic Legs

    Science.gov (United States)

    Ono, Kyosuke; Katsumata, Mie

    Walking with prosthesis has not been well analyzed mathematically and it seems that the design of powered prosthesis has been done empirically so far. This paper presents a dynamic simulation of a normal human walking and walking with an active prosthesis. We also studied the two controlling methods of a powered thigh prosthesis based on multi-body simulation of human walking. First we measured the normal human walking gait, then, we showed that a 3-DOF human walking model can walk on level ground by applying tracking control to the measured walking gait within a certain range of tuned walking period. Next, we applied the tracking control and self-excited control to the powered thigh prosthesis and compared the robustness and efficiency of the two control methods by numerical simulation. As a result, we found that the self-excited control can significantly decrease the hip joint torque and specific cost to 1/3 compared with the tracking control. Moreover, the self-excited control is superior to the tracking control because tuning for the walking period is not needed for the active prosthetic leg.

  2. Surface EMG in advanced hand prosthetics.

    Science.gov (United States)

    Castellini, Claudio; van der Smagt, Patrick

    2009-01-01

    One of the major problems when dealing with highly dexterous, active hand prostheses is their control by the patient wearing them. With the advances in mechatronics, building prosthetic hands with multiple active degrees of freedom is realisable, but actively controlling the position and especially the exerted force of each finger cannot yet be done naturally. This paper deals with advanced robotic hand control via surface electromyography. Building upon recent results, we show that machine learning, together with a simple downsampling algorithm, can be effectively used to control on-line, in real time, finger position as well as finger force of a highly dexterous robotic hand. The system determines the type of grasp a human subject is willing to use, and the required amount of force involved, with a high degree of accuracy. This represents a remarkable improvement with respect to the state-of-the-art of feed-forward control of dexterous mechanical hands, and opens up a scenario in which amputees will be able to control hand prostheses in a much finer way than it has so far been possible.

  3. Peri-prosthetic fracture vibration testing

    Energy Technology Data Exchange (ETDEWEB)

    Cruce, Jesse R [Los Alamos National Laboratory; Erwin, Jenny R [Los Alamos National Laboratory; Remick, Kevin R [Los Alamos National Laboratory; Cornwell, Phillip J [Los Alamos National Laboratory; Menegini, R. Michael [INDIANA UNIV.; Racanelli, Joe [STRYKER ORTHOPARDICS

    2010-11-08

    The purpose of this study was to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer and force response data from an instrumented stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing was conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem was instrumented with an accelerometer. Two impactor designs were compared: a monolithic impactor and a two-piece impactor, each with an integrated load cell and accelerometer. Acceleration and force measurements were taken in the direction of impaction. Comparisons between different methods of applying an impacting force were made, including a drop tower and a surgical hammer. The effect of varying compliance on the data was also investigated. The ultimate goal of this study was to assist in the design of an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental setup and the subsequent results of the comparisons made between impactors, prosthetic geometries, compliances, and impact methods. The results of this study can be used for both future replicate testing as well as in a cadaveric environment.

  4. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  5. American Dental Education Association

    Science.gov (United States)

    ... Interest Groups ADEA Governance Documents and Publications ADEA Dental Faculty Code of Conduct ADEA Bylaws ADEAGies Foundation ... Benefits for Faculty ADEA Member Benefits for Allied Dental Programs ADEA Member Benefits for Dental Schools ADEA ...

  6. Dental Holography

    Science.gov (United States)

    Dirtoft, Ingegerd

    1983-12-01

    Ten years have passed since the first articles appeared in this new field. The qualities of the laser light together with the need of contactless 3-D measurements for different dental purposes seemed to be extremely promising, but still just a few scientists have used the method and mostly for laboratory studies. For some reason there has been a preponderance for orthodontic measurements. This seems to be a bit peculiar from holographic view compared with measurements for engineering purposes, which usually are made on metals. So naturally holography can become a clinical tool for measurements in the field of fixed bridges, removable partial dentures and implants. One of the problems is that the need for holography in dental research must be fulfilled in collaboration with physicists. Only a two-way communication during an entire experiment can balance both technical and odontological demands and thus give practical and clinical important results. The need for an easy way of handling the evaluation to get all required information is another problem and of course the holographic equipment must be converted to a box easy to handle for everyone. At last the position of dental holography today is going to be carefully examined together with an attempt to look into the hopefully exciting and not to utopic future for this research field.

  7. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    Science.gov (United States)

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Danish dental education:

    DEFF Research Database (Denmark)

    Moore, Rod

    1985-01-01

    The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed.......The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed....

  9. Complete oral rehabilitation of a deep bite patient with Ewing’s sarcoma; surgical and prosthetic phases: A clinical report

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available Introduction: Ewings sarcoma (ES is an unusual, aggressive malignant neoplasm occurring primarily in the long bones of the lower and upper extremities followed by pelvis, ribs, vertebrae, skull, and jaws-bones. Patients with ES tumor need long-term complete oral reconstruction. The location of the primary tumor in the face is predominantly in the mandible, and usually in the posterior mandible. Case Report: Here, both surgical procedures and prosthetic reconstruction in three stages of a 10-year-old childs life presented. Definitive prosthetic reconstruction is extremely challenging in such patients after previous excessive surgical resection, especially when the patient has complex dental abnormality. Fixed dental prostheses and implant-supported fixed restorations have been selected as the preferred treatment option in this case after increasing occlusal vertical dimension (OVD to create sufficient interocclusal space (IOS. Discussion: In this case, ES patient treated in three phases. In the first-stage, only surgical resection of tumor and bone graft reconstruction with titanium plate fixation was performed. In the second-stage, Lefort I surgery for maxilla with dental implants insertion in mandible was done simultaneously. For definitive restorations fabrication, it was mandatory to increase occlusal vertical dimension (OVD to create sufficient inter-occlusal space (IOS for the restorations. OVD has been altered to achieve more stable relationship of mandibular teeth with maxillary teeth, and to obtain an optimum esthetic and functional result. Several factors should be considered as determinants for increasing the OVD such as remaining tooth structure, the space available for the restorations such as the current situation, occlusal variables, and esthetics.

  10. 100 top-cited scientific papers in limb prosthetics.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  11. Dental Procedures in Primary Health Care of the Brazilian National Health System

    Directory of Open Access Journals (Sweden)

    Suellen R. Mendes

    2017-12-01

    Full Text Available The aim of this study was to examine the procedures of primary dental health care performed by oral health teams (OHTs adhering to the second cycle of the ‘National Programme for Improving Access and Quality of Primary Care’ (PMAQ-AB in Brazil. A cross-sectional descriptive analysis was performed, across 23 dental procedures comprising preventive, restorative/prosthetic, surgical, endodontic and oral cancer monitoring. Descriptive analysis shows that most of the oral health teams carry out basic dental procedures. However, most of the time, they do not keep adequate records of suspected cases of oral cancer, diagnosis tests or follow-ups, and do not perform dental prosthetic procedures. Data also showed disparities in the average number of procedures performed in each Brazilian geographical region in 2013–2014, ranging from 13.9 in the northern to 16.5 in the southern and south-eastern regions, reinforcing the great social disparities between them. Brazilian regions with the highest volume of dental need deliver the lowest number of dental procedures. The need to tackle inequalities and further shape the supply of appropriate primary health care (PHC is evident.

  12. Dental optical coherence domain reflectometry explorer

    Energy Technology Data Exchange (ETDEWEB)

    Everett, Matthew J. (Livermore, CA); Colston, Jr., Billy W. (Livermore, CA); Sathyam, Ujwal S. (Livermore, CA); Da Silva, Luiz B. (Pleasanton, CA)

    2001-01-01

    A hand-held, fiber optic based dental device with optical coherence domain reflectometry (OCDR) sensing capabilities provides a profile of optical scattering as a function of depth in the tissue at the point where the tip of the dental explorer touches the tissue. This system provides information on the internal structure of the dental tissue, which is then used to detect caries and periodontal disease. A series of profiles of optical scattering or tissue microstructure are generated by moving the explorer across the tooth or other tissue. The profiles are combined to form a cross-sectional, or optical coherence tomography (OCT), image.

  13. Dental students--dental advocates.

    Science.gov (United States)

    Bensch, Brittany

    2010-01-01

    Student advocacy and involvement in the political process is built into the structure of the American Student Dental Association (ASDA), especially in its Legislative Grassroots Network and an internal communication network among students to ensure political awareness. Students are concerned with such issues as a universally accepted, non-patient-based licensure process, mid-level providers, loan availability and tax deductibility, financial support for schools, and service early in one's professional career (giving forward rather than giving back). Through collaboration with the American Dental Education Association and with many state associations, students participate in lobbying, awareness campaigns, and behind the scenes as legislative aids. Although students share the same love for the profession that animates established practitioners, they are perceived by legislators as being different. Students are involved in the legislative process because it represents their future.

  14. 21 CFR 872.1745 - Laser fluorescence caries detection device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Laser fluorescence caries detection device. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries detection device. (a) Identification. A laser fluorescence caries detection device is a laser, a...

  15. Pannus-related prosthetic valve dysfunction. Case report.

    Science.gov (United States)

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  16. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  17. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    Science.gov (United States)

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  18. Transforming Dental Technology Education: Skills, Knowledge, and Curricular Reform.

    Science.gov (United States)

    Bobich, Anita M; Mitchell, Betty L

    2017-09-01

    Dental technology is one of the core allied dental health professions supporting the practice of dentistry. By definition, it is the art, science, and technologies that enable the design and fabrication of dental prostheses and/or corrective devices to restore natural teeth and supporting structures to fulfill a patient's physiological and esthetic needs. Dental technology educational programs are faced with serious challenges, including rapid changes in technology, inadequate funding for educational programs, and the need to develop curricula that reflect current industry needs. Better communications between dental technologists and practitioners are needed to gain greater recognition of the contribution that technologists make to patient health. Amid these challenges, the technology workforce is dedicated to providing patients with the best possible restorative dental prostheses. This article was written as part of the project "Advancing Dental Education in the 21 st Century."

  19. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  20. Dental erozyon

    NARCIS (Netherlands)

    Özen, B.; Yönel, N.; Çetiner, S.

    2015-01-01

    Dental erozyon, plak içermeyen diş yüzeyleri üzerinde içsel ve dışsal asitlerin veya şelatların etkileriyle oluşan kimyasal bir aşınmadır. İçsel ve/veya dışsal kaynaklar nedensel faktörler olarak tanımlanırken tükürük ve pelikıl gibi biyolojik faktörler, yeme ve içme alışkanlıkları ve ağız hijyeni

  1. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  2. Prosthetic replacement vs space closure for maxillary lateral incisor agenesis: A systematic review.

    Science.gov (United States)

    Silveira, Giordani Santos; de Almeida, Natália Valli; Pereira, Daniele Masterson Tavares; Mattos, Cláudia Trindade; Mucha, José Nelson

    2016-08-01

    Defining the best treatment for maxillary lateral incisor agenesis is a challenge. Our aim in this study was to determine, with the evidence available in the literature, the best treatment for maxillary lateral incisor agenesis in the permanent dentition, evaluating the esthetic, occlusal (functional), and periodontal results between prosthetic replacement and orthodontic space closure. Electronic databases (CENTRAL, PubMed, Web of Science, Scopus, and LILACS) were searched in September 2014 and updated in January 2015, with no restriction on language or initial date. A manual search of the reference lists of the potential studies was performed. Risk of bias was assessed by the Newcastle Ottawa Scale. The search identified 2174 articles, of which 1196 were excluded because they were duplicates. Titles and abstracts of 978 articles were accessed, and 957 were excluded. In total, 21 articles were read in full, and 9 case-control studies were included after applying the inclusion and exclusion criteria. Data were extracted from the articles selected, and a table was compiled for comparison and analysis of the results. There were no randomization and blinding, and the risk of bias evaluation found gaps in compatibility and outcome domains in almost all selected studies. Tooth-supported dental prostheses of maxillary lateral incisor agenesis had worse scores in the periodontal indexes than did orthodontic space closure. Space closure is evaluated better esthetically than prosthetic replacements, and the presence or absence of a Class I relationship of the canines showed no relationship with occlusal function or with signs and symptoms of temporomandibular disorders. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  3. Smart dental practice: capitalising on smart mobile technology.

    Science.gov (United States)

    Plangger, K; Bredican, J; Mills, A J; Armstrong, J

    2015-08-14

    To keep pace with consumer adoption of smart mobile devices, such as smartphones and tablets, and the applications ('apps') developed for these devices, dental professionals should consider how this technology could be used to simultaneously improve both patient service experiences and dental practice management. Using U-Commerce as a theoretical lens, this article discusses the potential value of smart mobile technology to the dental practice context, with a particular focus on the unique and customisable capabilities of apps. To take full advantage of this technology, a process is outlined for identifying and designing bespoke dental apps that takes into account the unique advantages of these devices. Dental practices, with increasing financial and competitive pressures, may improve the efficiency and profitability of operations and better manage patients, employees and stakeholders by integrating smart mobile technology.

  4. Dental healthcare reforms in Germany and Japan: A comparison of statutory health insurance policy

    Directory of Open Access Journals (Sweden)

    Mayumi Nomura

    2008-10-01

    Full Text Available This article aims to compare statutory health insurance policy during the dental healthcare reforms in Germany and Japan. Germany and Japan have categorized their statutory health insurance systems. People in both countries have been provided with a wide coverage of dental treatment and prosthetics. To compare the trends of the indicators of oral healthcare systems over time, it has been suggested that the strategic allocation of dental expenditure is more important than the amount of expense. German dental healthcare policy has shifted under political and socio-economic pressures towards a cost-effective model. In contrast, Japanese healthcare reforms have focused on keeping the basic statutory health insurance scheme, whereby individuals share more of the cost of statutory health insurance. As a result, Germany has succeeded in dramatically decreasing the prevalence of dental caries among children. On comparing the dental conditions of both countries, the rate of decline in replacement of missing teeth among adults and the elderly in Germany and Japan has been interpreted as indicating the price-conscious demands of prosthetics. The difference in the decline of DMFT in 12-year-olds in Germany and Japan could be described as being due to the dental health insurance policy being shifted from treatment-oriented to preventive-oriented in Germany. These findings suggest that social health insurance provides people with equal opportunity for dental services, and healthcare reforms have improved people's oral health. A mixed coverage of social health insurance coverage for dental care should be reconsidered in Japan.

  5. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  6. Obtention of a prosthetic group for labelling of radioiodinated proteins

    International Nuclear Information System (INIS)

    Santos, Josefina da S.; Colturato, Maria Tereza; Araujo, Elaine B. de

    2000-01-01

    Antibodies and peptides labeled with radionuclides has been extensively used in radioimmunotherapy and radioimmunodetection. The principal problem with the use of radioiodinated proteins is the in vivo dehalogenation. The use of prosthetic groups for indirect labeling of proteins with radioiodine has showed to be useful on labeling proteins with greater in vivo stability. A procedure is described for the preparation of an radioiodinated prosthetic group (N-succinimidyl 4-radioiodine-benzoate-SIB), using procedure described by Stocklin et al, with the iodination of p-bromo-benzoic acid and subsequent reaction with TSTU. Preliminary labeling results showed that the prosthetic group can be obtained in a good yield. The coupling of the SIB to the protein will be studied using human IgG as protein model. (author)

  7. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    Science.gov (United States)

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  8. Weaker dental enamel explains dental decay.

    Science.gov (United States)

    Vieira, Alexandre R; Gibson, Carolyn W; Deeley, Kathleen; Xue, Hui; Li, Yong

    2015-01-01

    Dental caries continues to be the most prevalent bacteria-mediated non-contagious disease of humankind. Dental professionals assert the disease can be explained by poor oral hygiene and a diet rich in sugars but this does not account for caries free individuals exposed to the same risk factors. In order to test the hypothesis that amount of amelogenin during enamel development can influence caries susceptibility, we generated multiple strains of mice with varying levels of available amelogenin during dental development. Mechanical tests showed that dental enamel developed with less amelogenin is "weaker" while the dental enamel of animals over-expressing amelogenin appears to be more resistant to acid dissolution.

  9. Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications.

    Science.gov (United States)

    Fani, Simone; Bianchi, Matteo; Jain, Sonal; Pimenta Neto, José Simões; Boege, Scott; Grioli, Giorgio; Bicchi, Antonio; Santello, Marco

    2016-01-01

    Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the

  10. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  11. Effects of a 3D segmental prosthetic system for tricuspid valve annulus remodelling on the right coronary artery: a human cadaveric coronary angiography study.

    Science.gov (United States)

    Riki-Marishani, Mohsen; Gholoobi, Arash; Sazegar, Ghasem; Aazami, Mathias H; Hedjazi, Aria; Sajjadian, Maryam; Ebrahimi, Mahmoud; Aghaii-Zade Torabi, Ahmad

    2017-09-01

    A prosthetic system to repair secondary tricuspid valve regurgitation was developed. The conceptual engineering of the current device is based on 3D segmental remodelling of the tricuspid valve annulus in lieu of reductive annuloplasty. This study was designed to investigate the operational safety of the current prosthetic system with regard to the anatomical integrity of the right coronary artery (RCA) in fresh cadaveric human hearts. During the study period, from January to April 2016, the current prosthetic system was implanted on the tricuspid valve annulus in fresh cadaveric human hearts that met the study's inclusion criteria. The prepared specimens were investigated via selective coronary angiography of the RCA in the catheterization laboratory. The RCA angiographic anatomies were categorized as normal, distorted, kinked or occluded. Sixteen specimens underwent implantation of the current prosthetic system. The mean age of the cadaveric human hearts was 43.24 ± 15.79 years, with vehicle accident being the primary cause of death (59%). A dominant RCA was noticed in 62.5% of the specimens. None of the specimens displayed any injury, distortion, kinking or occlusion in the RCA due to the implantation of the prostheses. In light of the results of the present study, undertaken on fresh cadaveric human heart specimens, the current segmental prosthetic system for 3D remodelling of the tricuspid valve annulus seems to be safe vis-à-vis the anatomical integrity of the RCA. Further in vivo studies are needed to investigate the functional features of the current prosthetic system with a view to addressing the complex pathophysiology of secondary tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Prosthetic memory and post-memory: cultural encounters with the past in designing a museum

    Directory of Open Access Journals (Sweden)

    Mălina Ciocea

    2015-07-01

    Full Text Available This paper1 investigates the sources of representations on the communist period and the type of engagement with the past in an experiential museum, in the context of the National Network of Romanian Museums’ project for a laboratory-museum of Romanian Communism. Our analysis of focus-groups in October-November 2012 explores the public’s expectations in terms of museum experience and engagement with objects and the potential of an experiential museum to facilitate deliberation about the past. We use the conceptual framework of recent studies on postmemory (Hirsch, 2008 and prosthetic memory (Landsberg, 2004, 2009 to focus on ways of building the experiential archive needed to produce prosthetic memory. We consider that such an analysis is relevant for two interconnected problems: the bidirectional relationship between a projected museum of communism and a prospective public, and the methodological insights available for investigating this relation. With regard to the first problem, this paper makes a case for treating museums as a memory device rather than a lieu de memoire and analyses the role of the museum in relation to cultural memory. With regard to the second problem, it offers an example of conducting research on prospective publics which departs from traditional marketing approaches, adopting theoretical insights and analytical categories from specific conceptualizations in the field of memory studies.

  13. Lightweight custom composite prosthetic components using an additive manufacturing-based molding technique.

    Science.gov (United States)

    Leddy, Michael T; Belter, Joseph T; Gemmell, Kevin D; Dollar, Aaron M

    2015-01-01

    Additive manufacturing techniques are becoming more prominent and cost-effective as 3D printing becomes higher quality and more inexpensive. The idea of 3D printed prosthetics components promises affordable, customizable devices, but these systems currently have major shortcomings in durability and function. In this paper, we propose a fabrication method for custom composite prostheses utilizing additive manufacturing, allowing for customizability, as well the durability of professional prosthetics. The manufacturing process is completed using 3D printed molds in a multi-stage molding system, which creates a custom finger or palm with a lightweight epoxy foam core, a durable composite outer shell, and soft urethane gripping surfaces. The composite material was compared to 3D printed and aluminum materials using a three-point bending test to compare stiffness, as well as gravimetric measurements to compare weight. The composite finger demonstrates the largest stiffness with the lowest weight compared to other tested fingers, as well as having customizability and lower cost, proving to potentially be a substantial benefit to the development of upper-limb prostheses.

  14. Robotic hand with locking mechanism using TCP muscles for applications in prosthetic hand and humanoids

    Science.gov (United States)

    Saharan, Lokesh; Tadesse, Yonas

    2016-04-01

    This paper presents a biomimetic, lightweight, 3D printed and customizable robotic hand with locking mechanism consisting of Twisted and Coiled Polymer (TCP) muscles based on nylon precursor fibers as artificial muscles. Previously, we have presented a small-sized biomimetic hand using nylon based artificial muscles and fishing line muscles as actuators. The current study focuses on an adult-sized prosthetic hand with improved design and a position/force locking system. Energy efficiency is always a matter of concern to make compact, lightweight, durable and cost effective devices. In natural human hand, if we keep holding objects for long time, we get tired because of continuous use of energy for keeping the fingers in certain positions. Similarly, in prosthetic hands we also need to provide energy continuously to artificial muscles to hold the object for a certain period of time, which is certainly not energy efficient. In this work we, describe the design of the robotic hand and locking mechanism along with the experimental results on the performance of the locking mechanism.

  15. Psychometric evaluation of self-report outcome measures for prosthetic applications.

    Science.gov (United States)

    Hafner, Brian J; Morgan, Sara J; Askew, Robert L; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of importance to people with lower limb loss. Prosthesis users (n = 201) were randomly assigned to groups based on MoA (i.e., paper, electronic, or mixed-mode). Participants completed two surveys 2 to 3 d apart. Instruments included the Prosthetic Limb Users Survey of Mobility, Prosthesis Evaluation Questionnaire-Mobility Subscale, Activities-Specific Balance Confidence Scale, Quality of Life in Neurological Conditions-Applied Cognition/General Concerns, Patient-Reported Outcomes Measurement Information System Profile, and Socket Comfort Score. Intraclass correlation coefficients indicated all instruments are appropriate for group-level comparisons and select instruments are suitable for individual-level applications. Several instruments showed evidence of possible floor and ceiling effects. All were equivalent across MoAs. SEM and MDC were quantified to facilitate interpretation of outcomes and change scores. These results can enhance clinicians' and researchers' ability to select, apply, and interpret scores from instruments administered to prosthesis users.

  16. Development of nylon-based artificial muscles for the usage in robotic prosthetic limb

    Science.gov (United States)

    Atikah, Nurul Anis; Weng, Leong Yeng; Anuar, Adzly; Fat, Chau Chien; Abidin, Izham Zainal; Sahari, Khairul Salleh Mohamed

    2017-09-01

    This paper describes the development of nylon-based artificial muscles that is intended to be used in prosthetic limb for young amputees. Prosthetic limbs are very expensive and this situation is further compounded for young amputees who are very quickly out-grow their prosthesis. The proposed artificial muscles are made of nylon fishing strings from various size such as 0.45mm, 0.55mm, 0.65mm and 1.00mm. These fishing strings were twisted into coils to create Super Coiled Polymers (SCP) and tested using hot air blower. These artificial muscles react counterintuitively, where when it is exposed to heat, contracts, and when cooled, expands. Peltier devices, when switched-on acts as heat pump, where one side is hot and the other is cold. This phenomenon, when affixed in between 2 SCP's, creates tandem motion similar to triceps and biceps. As initial study, the hot side of the Peltier module was tested using these artificial muscles. The string was measured for both its force production, length contraction, the initial results were promising.

  17. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE.

    Science.gov (United States)

    Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  18. An experimental apparatus to simulate body-powered prosthetic usage: Development and preliminary evaluation.

    Science.gov (United States)

    Gao, Fan; Rodriguez, Johanan; Kapp, Susan

    2016-06-01

    Harness fitting in the body-powered prosthesis remains more art than science due to a lack of consistent and quantitative evaluation. The aim of this study was to develop a mechanical, human-body-shaped apparatus to simulate body-powered upper limb prosthetic usage and evaluate its capability of quantitative examination of harness configuration. The apparatus was built upon a torso of a wooden mannequin and integrated major mechanical joints to simulate terminal device operation. Sensors were used to register cable tension, cable excursion, and grip force simultaneously. The apparatus allowed the scapula to move up to 127 mm laterally and the load cell can measure the cable tension up to 445 N. Our preliminary evaluation highlighted the needs and importance of investigating harness configurations in a systematic and controllable manner. The apparatus allows objective, systematic, and quantitative evaluation of effects of realistic harness configurations and will provide insightful and working knowledge on harness fitting in upper limb amputees using body-powered prosthesis. © The International Society for Prosthetics and Orthotics 2015.

  19. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  20. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  1. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    International Nuclear Information System (INIS)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    2014-01-01

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if timely management is started. Literature shows no uniform advise on diagnosis. The EANM organized a consensus meeting with representatives from the involved disciplines in order to develop common flowcharts for the diagnosis of osteomyelitis, spondylodiscitis and prosthetic joint infections. In this report the proceedings of this consensus meeting, including the proposed flowcharts for diagnosis, are published.

  2. Prevalence of dental erosion among people with gastroesophageal reflux disease in China.

    Science.gov (United States)

    Li, Wenhao; Liu, Jingming; Chen, Su; Wang, Yao; Zhang, Zhenting

    2017-01-01

    Gastroesophageal reflux disease (GERD) is typically diagnosed based on symptoms of regurgitation and heartburn, although it may also manifest as asthma-like symptoms, laryngitis, or dental erosion. The purpose of this prospective, cross-sectional study was to assess the prevalence of dental erosion in people with GERD and to evaluate the association between GERD and dental erosion. The presence, severity, and pattern of dental erosion was assessed in 51 participants with GERD and 50 participants without GERD using the Smith and Knight tooth wear index. Medical, dietary, and dental histories were collected by questionnaire. Factors potentially related to dental erosion, including GERD, were evaluated by logistic regression. Dental erosion was observed in 31 (60.8%) participants with GERD and 14 (28%) participants without GERD. Bivariate analysis revealed that participants with GERD were more likely to experience dental erosion (crude odds ratio [cOR]: 2.74; 95% CI: 1.19, 6.32) than participants without GERD. Multivariate analysis also revealed that participants with GERD had a higher risk of dental erosion (adjusted odds ratio [aOR]: 3.97; 95% CI: 1.45, 10.89). Consumption of grains and legumes, the most frequently consumed foods in China, did not correlate with dental erosion. However, carbonated beverage consumption was significantly associated with GERD and dental erosion (aOR: 3.34; 95% CI: 1.01, 11.04; P=.04). GERD was positively correlated with dental erosion. Carbonated beverage consumption can increase the risk of both GERD and dental erosion. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Quality improvement program reduces perioperative dental injuries – A review of 64,718 anesthetic patients

    Directory of Open Access Journals (Sweden)

    Yi-Wei Kuo

    2016-12-01

    Conclusion: Dental injury incidence was significantly reduced and remained at low levels after implementation of the quality improvement program. We suggest the implementation of a standardized dental examination into the preoperative evaluation system adding pathologic teeth fixed or protected devices to minimize dental injury associated with anesthesia.

  4. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    OpenAIRE

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access ...

  5. Adapting to change: influence of a microprocessor-controlled prosthetic knee on gait adaptations

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan

    2016-01-01

    Advancement in prosthetic knee design have led to the introduction of microprocessor-controlled prosthetic knees (MPKs). MPKs incorporate sensors that are able to measure prosthetic loading, the knee angle, and knee angular velocity. Based on the sensor information, MPKs determine the optimal level

  6. Enhancing the online presence of a dental practice.

    Science.gov (United States)

    McLeod, Neil S

    2012-04-01

    This article describes methods for enhancing the online presence of a dental practice to gain market share and facilitate communication with current and prospective patients. Topics discussed include creation of a website that will help patients easily locate the practice. The importance of back links and embedded keywords is stressed. A method for identifying competitors' online marketing strategies also is presented, along with discussions of patient reviews and pay-per-click advertising options. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  7. Oral rehabilitation of segmental mandibulectomy patient with osseointegrated dental implant

    Directory of Open Access Journals (Sweden)

    Archana Singh

    2014-01-01

    Full Text Available Surgical management of oral cancer lesions results in explicit aesthetic and functional disfigurement, including facial deformity, loss of hard and soft tissue, impaired speech, swallowing and mastication, which modify the patient′s self-image and quality-of-life. Recent advances in head and neck reconstruction techniques and dental implant based prosthetic rehabilitation may significantly improve the quality-of-life and self-esteem for such post-surgery patients. This clinical report describes rehabilitation of oral cancer patient having segmental mandibulectomy with implant-supported fixed partial denture.

  8. Noninvasive method for retrieval of broken dental implant abutment screw

    Directory of Open Access Journals (Sweden)

    Jagadish Reddy Gooty

    2014-01-01

    Full Text Available Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.

  9. Dental Management of Ectodermal Dysplasia: Two Clinical Case Reports

    Directory of Open Access Journals (Sweden)

    Somayeh Hekmatfar

    2012-06-01

    Full Text Available Ectodermal dysplasia is a hereditary disorder associated with abnormal development of embryonic ectodermally-derived organs including teeth, nails, hair and sweat glands. Hypodontia of the primary and permanent dentition is the most common oral finding. Therefore, affected patients need dental prosthetic treatments during their developmental years. This report presents two cases of children affected by ectodermal dysplasia with anodontia. Oral rehabilitation was accomplished with removable acrylic prostheses. Treatment had major impacts on self-esteem, masticatory function, speech and facial esthetic.

  10. Enamel microabrasion for aesthetic management of dental fluorosis.

    Science.gov (United States)

    Pandey, Pallavi; Ansari, Afroz Alam; Moda, Preeti; Yadav, Madhulika

    2013-10-11

    Fluorosis has increased in recent times due to fluoridation of drinking water and addition of fluoride to various edible items, which leads to unaesthetic appearance of teeth visible at close quarters. The enamel microabrasion technique is a conservative method that improves the appearance of the teeth by restoring bright and superficial smoothness, without causing significant structural loss. The aim of this article is to describe an easy technique for managing mild to moderate dental fluorosis using Opalustre (Ultradent Products) microabrasion slurry. This conservative approach may be considered an interesting alternative to more invasive prosthetic techniques like composite resin restorations, ceramic veneers or crown fabrications.

  11. Methods to measure stability of dental implants

    Directory of Open Access Journals (Sweden)

    Shruti Digholkar

    2014-01-01

    Full Text Available Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion and secondary stability (bone formation and remodeling at implant-bone interface. However, due to the invasive nature of the histological methods various other methods have been proposed: Radiographs, the surgeon′s perception, Insertion torque (cutting torque analysis, seating torque, reverse torque testing, percussion testing, impact hammer method, pulsed oscillation waveform, implant mobility checker, Periotest, resonance frequency analysis. This review focuses on the methods currently available for the evaluation of implant stability.

  12. Patient satisfaction and prosthetic aspects with mini-implants retained mandibular overdentures. A 5-year prospective study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou

    2016-07-01

    This study aimed to evaluate patient satisfaction and prosthetic aspects during a 5-year prospective clinical study of mini dental implants (MDIs) retaining mandibular overdentures. This observational prospective clinical study was conducted on a group of completely edentulous patients (n = 28) with retention problems of conventional mandibular dentures. All patients received new maxillary and mandibular conventional dentures. A total of 112 MDIs (four per patient) were inserted using the flapless surgical approach and immediately loaded by the new mandibular dentures (overdentures). Patients indicated satisfaction with their prosthesis using a questionnaire and a visual analogue scale (VAS). Patient satisfaction and prosthetic complications were recorded 6 months (T6 m ), 1 (T1), 3 (T3), and 5 (T5) years after overdenture insertion. The patient satisfaction with eating (hard/soft) food (P teeth (n = 10), overdentures relines (n = 10), detachment of the metal housings (n = 9), and fracture of mandibular overdentures (n = 8). Mucositis, soreness, and decubitis ulcer under overdenture occurred most often at T6 m and decreased significantly with time (P = 0.002, 0.005, and 0.024, respectively). Within the limitations of this clinical study, patient satisfaction with mini-implant retained mandibular overdentures increased significantly with time. However, this treatment required a considerable amount of prosthetic maintenance and repair after 5 years of service. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  14. A model to facilitate implementation of the International Classification of Functioning, Disability and Health into prosthetics and orthotics.

    Science.gov (United States)

    Jarl, Gustav; Ramstrand, Nerrolyn

    2017-09-01

    The International Classification of Functioning, Disability and Health is a classification of human functioning and disability and is based on a biopsychosocial model of health. As such, International Classification of Functioning, Disability and Health seems suitable as a basis for constructing models defining the clinical P&O process. The aim was to use International Classification of Functioning, Disability and Health to facilitate development of such a model. Proposed model: A model, the Prosthetic and Orthotic Process (POP) model, is proposed. The Prosthetic and Orthotic Process model is based on the concepts of the International Classification of Functioning, Disability and Health and comprises four steps in a cycle: (1) Assessment, including the medical history and physical examination of the patient. (2) Goals, specified on four levels including those related to participation, activity, body functions and structures and technical requirements of the device. (3) Intervention, in which the appropriate course of action is determined based on the specified goal and evidence-based practice. (4) Evaluation of outcomes, where the outcomes are assessed and compared to the corresponding goals. After the evaluation of goal fulfilment, the first cycle in the process is complete, and a broad evaluation is now made including overriding questions about the patient's satisfaction with the outcomes and the process. This evaluation will determine if the process should be ended or if another cycle in the process should be initiated. The Prosthetic and Orthotic Process model can provide a common understanding of the P&O process. Concepts of International Classification of Functioning, Disability and Health have been incorporated into the model to facilitate communication with other rehabilitation professionals and encourage a holistic and patient-centred approach in clinical practice. Clinical relevance The Prosthetic and Orthotic Process model can support the implementation

  15. A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

    Science.gov (United States)

    Wagner, Martin G; Hatt, Charles R; Dunkerley, David A P; Bodart, Lindsay E; Raval, Amish N; Speidel, Michael A

    2018-04-16

    Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure in which a prosthetic heart valve is placed and expanded within a defective aortic valve. The device placement is commonly performed using two-dimensional (2D) fluoroscopic imaging. Within this work, we propose a novel technique to track the motion and deformation of the prosthetic valve in three dimensions based on biplane fluoroscopic image sequences. The tracking approach uses a parameterized point cloud model of the valve stent which can undergo rigid three-dimensional (3D) transformation and different modes of expansion. Rigid elements of the model are individually rotated and translated in three dimensions to approximate the motions of the stent. Tracking is performed using an iterative 2D-3D registration procedure which estimates the model parameters by minimizing the mean-squared image values at the positions of the forward-projected model points. Additionally, an initialization technique is proposed, which locates clusters of salient features to determine the initial position and orientation of the model. The proposed algorithms were evaluated based on simulations using a digital 4D CT phantom as well as experimentally acquired images of a prosthetic valve inside a chest phantom with anatomical background features. The target registration error was 0.12 ± 0.04 mm in the simulations and 0.64 ± 0.09 mm in the experimental data. The proposed algorithm could be used to generate 3D visualization of the prosthetic valve from two projections. In combination with soft-tissue sensitive-imaging techniques like transesophageal echocardiography, this technique could enable 3D image guidance during TAVR procedures. © 2018 American Association of Physicists in Medicine.

  16. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  17. DEGREE OF AWARENESS OF SOFT RELINING MATERIALS BY DENTAL TECHNICIANS

    Directory of Open Access Journals (Sweden)

    Ilian Hristov

    2017-10-01

    Full Text Available The aim of the current investigation is to analyze the dental-technicians’ awareness of the soft relining materials, their characteristics, advantages, shortcomings and methods for relining. Materials and methods: For the purpose of this investigation a standard questionnaire has been presented. A direct survey method, documentary and statistical method, as well as graphical methods, including tables, charts, graphics and figures, were used. Data were analysed with the help of IBM SPSS Statistics (ver. 19. Results: One hundred and eight dental technicians were included in the survey, evenly distributed by gender. Removable and fixed prosthodontics is the most commonly mentioned spheres of dental activities. Almost all included in the investigation point out the laboratory relining method as the most frequently used. Acrylic and silicone SRM are the most used groups of relining materials. Change of colour and hardness are the most frequently noticed shortcomings of these materials. The majority of the dental technicians declare that they have never done replacement of SRM or the relining has lasted more than a year. Discussion: The correlation between the age and the years of labour service among the participants is quite obvious. Most of them start working soon after their graduation. Removable prosthodontics is among the priorities for the majority of the labs. Conclusion: Although their unambiguous advantages, the soft relining materials have lots of shortcomings as well. The major problems are connected with their change of colour and hardness. Nevertheless, the dental technicians find them useful and reliable in overcoming specific prosthetic problems.

  18. An experimental bioactive dental ceramic for metal-ceramic restorations: Textural characteristics and investigation of the mechanical properties.

    Science.gov (United States)

    Goudouri, Ourania-Menti; Kontonasaki, Eleana; Papadopoulou, Lambrini; Manda, Marianthi; Kavouras, Panagiotis; Triantafyllidis, Konstantinos S; Stefanidou, Maria; Koidis, Petros; Paraskevopoulos, Konstantinos M

    2017-02-01

    The aim of this study was the evaluation of the textural characteristics of an experimental sol-gel derived feldspathic dental ceramic, which has already been proven bioactive and the investigation of its flexural strength through Weibull Statistical Analysis. The null hypothesis was that the flexural strength of the experimental and the commercial dental ceramic would be of the same order, resulting in a dental ceramic with apatite forming ability and adequate mechanical integrity. Although the flexural strength of the experimental ceramics was not statistically significant different compared to the commercial one, the amount of blind pores due to processing was greater. The textural characteristics of the experimental ceramic were in accordance with the standard low porosity levels reported for dental ceramics used for fixed prosthetic restorations. Feldspathic dental ceramics with typical textural characteristics and advanced mechanical properties as well as enhanced apatite forming ability can be synthesized through the sol-gel method. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Prototyping for surgical and prosthetic treatment.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Santos, Murillo Rezende; Pesqueira, Aldiéris Alves; Moreno, Amália; dos Santos, Daniela Micheline; Haddad, Marcela Filié

    2011-05-01

    Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE (PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.

  20. Survey of radiologic practices among dental practitioners

    International Nuclear Information System (INIS)

    Goren, A.D.; Sciubba, J.J.; Friedman, R.; Malamud, H.

    1989-01-01

    The purpose of this study was to determine the factors that influence and contribute to patient exposure in radiologic procedures performed in the offices of 132 staff members within the dental department of a teaching hospital. A questionnaire was prepared in which data were requested on brands of film used, type of x-ray unit used, processing, and use of leaded apron, cervical shield, and film holder. Offices were also visited to evaluate performance of existing dental x-ray equipment. Both the Dental Radiographic Normalizing and Monitoring Device and the Dental Quality Control Test Tool were evaluated. The average exposure was equivalent to the class D film (220 mR), but only 13% of those surveyed used the faster class E film, which would reduce patient exposure in half. The survey indicates that dentists are not using the newer low-exposure class E film in their practices

  1. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  2. Consumer satisfaction with the services of prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U.

    2009-01-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (PO) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 PO facilities in The Netherlands. Consumers (n=1,364) of these PO facilities who

  3. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  4. Esthetics with prosthetics in case of maxillary canine transposition: A ...

    African Journals Online (AJOL)

    Esthetics with prosthetics in case of maxillary canine transposition: A clinical report. ... provides a helpful Frequently Asked Questions about PDFs. Alternatively, you can download the PDF file directly to your computer, from where it can be opened using a PDF reader. To download the PDF, click the Download link above.

  5. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  6. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  7. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    2011-01-01

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  8. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  9. Effect of Modifying Prosthetic Socket Base Materials by Adding Nanodiamonds

    Directory of Open Access Journals (Sweden)

    Lifang Ma

    2015-01-01

    Full Text Available The curing process of prosthetic socket base materials requires attention owing to a series of associated problems that are yet to be addressed and solved. However, to date, few relevant studies have been reported. In this paper, nanodiamonds modified with a silane coupling agent were dispersed into a prosthetic socket base material, and the performance of the modified base materials was investigated. Adding a predetermined amount of nanodiamonds to the prosthetic socket base material increased the glass transition temperature, improved the mechanical properties of the cured base material, and reduced the influence of the volatile gas formed during the curing process on the environment. With increasing nanodiamond contents, the glass transition temperature increased and the mechanical properties improved slightly. Owing to the high thermal conductivity of the nanodiamonds, the localized heat, as a result of the curing process, could be dissipated and released. Thus, adding nanodiamonds led to a more uniform temperature field forming in the curing system. This improved the curing process and reduced the formation of volatile monomers, thereby decreasing the adverse impact of the generated volatile gases on the environment. All of these provide a potential strategy for modifying prosthetic socket base materials.

  10. Prosthetic prescription in the Netherlands : an observational study

    NARCIS (Netherlands)

    van der Linde, H; Geertzen, JHB; Hofstad, CJ; Postema, K; Van Limbeek, Jacques

    2003-01-01

    Prosthetic prescription for lower limb amputees and the methodology used are primarily based on empirical knowledge. Clinical expertise plays an important role that can lead to an adequate prescription; however, a clear evidence based motivation for the choices made cannot be given. This can lead to

  11. Dental students' uptake of mobile technologies.

    Science.gov (United States)

    Khatoon, B; Hill, K B; Walmsley, A D

    2014-06-01

    The aim of this study was to understand how new mobile technologies, such as smartphones and laptops, are used by dental students. A questionnaire was distributed to undergraduate dental students from years 1 to 4, at the University of Birmingham Dental School. Questionnaires were completed between February and April 2013. Two hundred and seventy questionnaires were completed. Laptops 55% (145) and smartphones 34% (88) were the most popular choice of device for connecting to the net and searching information. Laptops were preferred in first and second year. Students in year 3 preferred mobile phones, and by year 4 the use of mobile phones and laptops was similar. The top two application ideas chosen by students as the most useful on their smart phones were a dictionary for dental education (56%) and multiple choice questions (50%). Students who chose smartphones as their first choice or second choice of device strongly agreed that having the Internet on their smartphones had a positive impact on their dental education (55%). With laptops (48%), students preferred to be at home when using them while for smartphones (31%) they used them anywhere with a connection. E-mail (47%) and social networks (44%) were the top two Internet communication tools used most on laptops. Instant messaging was popular on smartphones (17%). Depending on the year in the course, laptops and smartphones are the most popular choice of device and desktop computers are the least popular. Applications on smartphones are very popular and instant messaging is an upcoming form of communication for students.

  12. A new three-dimensional, print-on-demand temporomandibular prosthetic total joint replacement system: Preliminary outcomes.

    Science.gov (United States)

    Dimitroulis, George; Austin, Stephen; Sin Lee, Peter Vee; Ackland, David

    2018-05-16

    The aim of this study is to present the preliminary clinical data on the OMX Temporomandibular Joint (TMJ) Prosthetic total joint replacement system. A prospective, cohort, clinical study was undertaken of consecutive adult patients with Category 5 end-stage joint disease who were implanted with the OMX TMJ prosthesis between May 2015 and April 2017. A total of 50 devices were implanted in 38 patients, with 12 patients receiving bilateral prosthetic joints. There were 31 females and 7 males in this cohort, who ranged in age from 20 to 66 years, with a mean of 43.8 years (±14.0 years). Ten of the 50 prosthetic joints (20%) were fully customized, while the remaining were patient matched using virtual planning software. Based on a mean follow-up period of 15.3 months (range 12-24 months) following the TMJ total joint replacement, preliminary results suggest the OMX TMJ prosthesis has made a positive impact on clinical outcomes, with a mean 74.4% reduction in joint pain levels and significant improvements (p < 0.05) in jaw function as measured by the visual analogue scales for mouth opening (30.8%), diet (77.1%), and function (59.2%). No device failures were reported during the study period. This study suggests that the print-on-demand OMX TMJ prosthesis, designed for rapid delivery of both patient-matched and fully customize devices, represents a safe, reliable and versatile implantable joint replacement system for the treatment of category 5 end-stage TMJ disease. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Detection and identification of microbes in prosthetic joint infections by culture and molecular methods

    DEFF Research Database (Denmark)

    Xu, Yijuan; Schønheyder, Henrik Carl; Ehrlich, Garth

    , indicating biofilm formation. In conclusion, this study indicated that to improve the microbiological diagnosis of prosthetic joint infections molecular methods may be useful supplements to routine cultures, and the current intraoperative sampling strategy needs to be optimized.......Bacterial biofilms have been observed in many device-related infections including orthopedic implants. This mode of growth makes the infection difficult to treat and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study...... uncovered many more species including known pathogens and species not previously reported in orthopedic infections, and polymicrobial communities were commonly observed. Additionally the molecular findings suggested the bacterial composition and yield varied depending on the position and type of samples...

  14. Quality Assessment of Prosthetic Rehabilitation Using Aesthetic Fixed Restorations

    Directory of Open Access Journals (Sweden)

    Zinovii Ozhohan

    2018-04-01

    Full Text Available The objective of the research was to study and assess the quality of prosthetic treatment using aesthetic fixed restorations. Materials and methods. The study included 79 patients without a comorbidity who underwent prosthetic rehabilitation. All the patients were divided into 3 groups: Group I included 25 patients with metal-plastic restorations; Group II comprised 34 patients with porcelain-fused-to-metal restorations; Group III consisted of 20 patients with a combined occlusal surface of prosthetic restorations. The patients were observed 6 months after prosthetic repair. Only patients with single molar and premolar crowns were examined. Bridge prostheses were not taken into account in order to eliminate the effect of masticatory force redistribution on the abutment crowns. Results. In Group I, 11 (44% patients were satisfied with the results of prosthetic treatment. In Group II, 25 (78.12% patients reported that they were satisfied with their treatment. In Group III, there were 17 (85% patients satisfied with their outcome. However, the patients’ complaints are often subjective and do not fully reflect the objective state of the dentoalveolar system. An objective examination revealed that in indirect restorations, marginal periodontium pathology is typical. Conclusions. Aesthetic fixed restorations with a combined occlusal surface have demonstrated good clinical results, even at long-term follow-up. Combining positive properties of two different construction materials, namely zirconium dioxide and ceramics, they reduce the risk of complications such as marginal periodontium pathology and chipping along the occlusal surface as well as contribute to minimal abrasion of the occlusal surfaces of the antagonistic teeth. We cannot recommend metal-plastic restorations due to their low clinical effectiveness, poor aesthetic qualities as well as a high level of marginal periodontium pathology.

  15. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  16. Comparison of multimedia system and conventional method in patients’ selecting prosthetic treatment

    Directory of Open Access Journals (Sweden)

    Baghai R

    2010-12-01

    Full Text Available "nBackground and Aims: Selecting an appropriate treatment plan is one of the most critical aspects of dental treatments. The purpose of this study was to compare multimedia system and conventional method in patients' selecting prosthetic treatment and the time consumed."nMaterials and Methods: Ninety patients were randomly divided into three groups. Patients in group A, once were instructed using the conventional method of dental office and once multimedia system and time was measured in seconds from the beginning of the instruction till the patient had came to decision. The patients were asked about the satisfaction of the method used for them. In group B, patients were only instructed using the conventional method, whereas they were only exposed to soft ware in group C. The data were analyzed with Paired-T-test"n(in group A and T-test and Mann-Whitney test (in groups B and C."nResult: There was a significant difference between multimedia system and conventional method in group A and also between groups B and C (P<0.001. In group A and between groups B and C, patient's satisfaction about multimedia system was better. However, in comparison between groups B and C, multimedia system did not have a significant effect in treatment selection score (P=0.08."nConclusion: Using multimedia system is recommended due to its high ability in giving answers to a large number of patient's questions as well as in terms of marketing.

  17. Dutch evidence-based guidelines for amputation and prosthetics of the lower extremity : Rehabilitation process and prosthetics. Part 2

    NARCIS (Netherlands)

    Geertzen, Jan; van der Linde, Harmen; Rosenbrand, Kitty; Conradi, Marcel; Deckers, Jos; Koning, Jan; Rietman, Hans S.; van der Schaaf, Dick; van der Ploeg, Rein; Schapendonk, Johannes; Schrier, Ernst; Duijzentkunst, Rob Smit; Spruit-van Eijk, Monica; Versteegen, Gerbrig; Voesten, Harrie

    2015-01-01

    Background: A structured, multidisciplinary approach in the rehabilitation process after amputation is needed that includes a greater focus on the involvement of both (para)medics and prosthetists. There is considerable variation in prosthetic prescription concerning the moment of initial prosthesis

  18. High resolution ultrastructure imaging of fractures in human dental tissues

    Directory of Open Access Journals (Sweden)

    Tan Sui

    2014-01-01

    Full Text Available Human dental hard tissues are dentine, cementum, and enamel. These are hydrated mineralised composite tissues with a hierarchical structure and versatile thermo-mechanical properties. The hierarchical structure of dentine and enamel was imaged by transmission electron microscopy (TEM of samples prepared by focused ion beam (FIB milling. High resolution TEM was carried out in the vicinity of a crack tip in dentine. An intricate “random weave” pattern of hydroxyapatile crystallites was observed and this provided a possible explanation for toughening of the mineralized dentine tissue at the nano-scale. The results reported here provide the basis for improved understanding of the relationship between the multi-scale nature and the mechanical properties of hierarchically structured biomaterials, and will also be useful for the development of better prosthetic and dental restorative materials.

  19. Fifteen years of follow-up of a removable prosthetic design to maintain two remaining molars in a patient with mandibular reconstruction

    OpenAIRE

    Ming-Lun Hsu; Jacqueline Chia-Hsuan Wu; Ling-Ming Yu

    2012-01-01

    This clinical report describes a long-term prosthetic solution for a patient who had undergone mandibular reconstruction with a fibular graft, leaving only two right molars. The only retention device for the removable prosthesis design included a telescoping system with an O-ring application, but without fibula graft involvement. This prosthesis design was motivated by the altered bony and muscular architecture resulting in an increased maxillomandibular space and thick soft tissue in the den...

  20. Understanding dental CAD/CAM for restorations--dental milling machines from a mechanical engineering viewpoint. Part B: labside milling machines.

    Science.gov (United States)

    Lebon, Nicolas; Tapie, Laurent; Duret, Francois; Attal, Jean-Pierre

    2016-01-01

    Nowadays, dental numerical controlled (NC) milling machines are available for dental laboratories (labside solution) and dental production centers. This article provides a mechanical engineering approach to NC milling machines to help dental technicians understand the involvement of technology in digital dentistry practice. The technical and economic criteria are described for four labside and two production center dental NC milling machines available on the market. The technical criteria are focused on the capacities of the embedded technologies of milling machines to mill prosthetic materials and various restoration shapes. The economic criteria are focused on investment cost and interoperability with third-party software. The clinical relevance of the technology is discussed through the accuracy and integrity of the restoration. It can be asserted that dental production center milling machines offer a wider range of materials and types of restoration shapes than labside solutions, while labside solutions offer a wider range than chairside solutions. The accuracy and integrity of restorations may be improved as a function of the embedded technologies provided. However, the more complex the technical solutions available, the more skilled the user must be. Investment cost and interoperability with third-party software increase according to the quality of the embedded technologies implemented. Each private dental practice may decide which fabrication option to use depending on the scope of the practice.

  1. Missing Teeth and Prosthetic Treatment in Patients Treated at College of Dentistry, University of Dammam

    Directory of Open Access Journals (Sweden)

    Shaimaa M. Fouda

    2017-01-01

    Full Text Available The percentage of completely and partially edentulous patients and their prosthetic treatment at the Department of Substitutive Dental Sciences (SDS, College of Dentistry, University of Dammam, were investigated. Panoramic radiographs and medical records of adult patients (n=479, mean age 45.9 years, and range 25–96 years treated in 2011–2014 were examined. 6% of the patients were completely edentulous, 8% had single jaw edentulousness, and 74% were partially edentulous. Edentulousness was significantly correlated with age and the number of missing teeth was significantly higher among males (p<0.026. Diabetes was significantly associated with complete edentulousness, single edentulous jaw (p value 0.015, and partial edentulousness (p value 0.023. Kennedy class III was the most frequent class of partial edentulousness in single and/or both jaws (p=0.000. Patients having class I and/or class II were treated most often with removable partial dentures (RPD (p=0.000, while patients having class III were treated with fixed partial dentures (FPD. It was found that complete edentulousness increases in older age and the number of missing teeth was significantly higher among males. Kennedy class III was most common in both upper and lower jaw and was treated more often with FPD than with RPD.

  2. A model of blended learning in a preclinical course in prosthetic dentistry.

    Science.gov (United States)

    Reissmann, Daniel R; Sierwald, Ira; Berger, Florian; Heydecke, Guido

    2015-02-01

    The aim of this study was to evaluate the use of blending learning that added online tools to traditional learning methods in a preclinical course in prosthetic dentistry at one dental school in Germany. The e-learning modules were comprised of three main components: fundamental principles, additional information, and learning objective tests. Video recordings of practical demonstrations were prepared and cut into sequences meant to achieve single learning goals. The films were accompanied by background information and, after digital processing, were made available online. Additionally, learning objective tests and learning contents were integrated. Evaluations of 71 of 89 students (response rate: 80%) in the course with the integrated e-learning content were available for the study. Compared with evaluation results of the previous years, a substantial and statistically significant increase in satisfaction with learning content (from 30% and 34% to 86%, plearning effect (from 65% and 63% to 83%, pblended learning concept. The results showed that the e-learning tool was appreciated by the students and suggest that learning objective tests can be successfully implemented in blended learning.

  3. Material selection for prosthetics of defects of dentitions at patients with functional and inflammatory bowel diseases

    Directory of Open Access Journals (Sweden)

    Myalina Yu.N.

    2012-06-01

    Full Text Available Objective: To study clinical-morphological characteristics of parodontal diseases, markers of density of bone tissue and to define rational approaches to prosthetics of defects of dentitions in patients with colon diseases. Materials and methods: 55 patients with ulcerative colitis, even 80 with the syndrome of the irritable bowel syndrome with defects of dentitions, have been applied metallic, cement prostheses and having prostheses on the intraosseous of implants. Markers of bone metabolism in the blood serum and in the oral liquid, the proliferating activity of the epitheliocytes of periodontium have been evaluated according to the morphometric indices of the markers of the proliferation of ki-67, cyclein D1, the inhibitor of apoptosis of bcl-2 have been inspected. Results: Connection of intensity of periodontitis with the stage of colon disease has been stated. Metallic dental prostheses have been served as additional risk factors of development of parodontal diseases in patients with ulcerative colitis. Conclusion: The diagnostic value of the markers of proliferation has been determined in diagnostics of parodontal disease during the application of prostheses from different materials.

  4. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Directory of Open Access Journals (Sweden)

    Érica Dorigatti de Avila

    2014-01-01

    Full Text Available When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i abutment substitution to compensate the incorrect angulation of the implant, (ii clinical crown lengthening, (iii atraumatic extraction of the left central incisor, and (iv immediate implant placement. Finally, (v a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

  5. Prospective clinical study of prosthetic treatment outcome of implantretained-removable-partial-denture during 5 year-follow-ups

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-11-01

    Full Text Available Background IRRPD offers patients the ability to upgrade their treatment planning to implant-supported-overdentures (ISOs or implant-supported-fixed-prostheses (ISFPs through insertion of more implants in the future after the loss of the remaining natural teeth. Aims The purpose of this prospective-clinical-study was to evaluate the success rate and treatment outcome of IRRPD for 15 patients, during at least 5-year-follow-ups after prosthetic rehabilitation with respect to implant mobility, peri-implant-marginal-bone-levels, and prosthetic complications. Methods 15 successive patients were attended the Department of Implantology and Prosthodontics in TUMS, and received Implant-Retained-Removable-Partial-Dentures (IRRPDs. Two standard-size-dental-implants (Implantium/Dentium system, internal hexagon, Seoul, South Korea were placed in distal-extension-areas for each patient. After the osseointegration period, all patients received IRRPDs using two Ball attachments. All the participated patients were followed-up at least for 5 years, and the survival rate of 30 implants was evaluated. The patients’ satisfaction of function, phonetics, and aesthetics was assessed by means of questionnaire. Results None of the studied patients reported any prosthetic complications during the follow-up-periods such as attachment loosening, metal housing loosening, or denture fracture. No implants failure was recorded, so that the cumulative-implant-survival rate was 100 per cent. The mean marginal-bone-resorption (MBR around the two implants was 0.9mm with a range of 0.5–1.4mm. Teeth aesthetics was judged as excellent or very good by 86.7 per cent of the patients, while phonetics and mastication were considered excellent or very good by 66.7 per cent and 73.3 per cent of the patients, respectively. Conclusion 15 patients received 30 implants for the fabrication of IRRPDs in the posterior-edentulous-sites. The IRRPDs were delivered to the patients by the same

  6. In vitro color evaluation of esthetic coatings for metallic dental implants and implant prosthetic appliances.

    Science.gov (United States)

    Pecnik, Christina M; Roos, Malgorzata; Muff, Daniel; Spolenak, Ralph; Sailer, Irena

    2015-05-01

    The aim of this study was to characterize the optical properties of newly developed esthetic coatings for metallic implants and components for an improved peri-implant soft tissue appearance. Pig maxillae (n = 6) were used for the in vitro color evaluation of coated and uncoated samples. Three different coating systems (Ti-ZrO(2), Ti-Al-ZrO(2), and Ti-Ag-ZrO(2)) were deposited on titanium substrates, which exhibited different roughness (polished, machined, and sand-blasted) and interference colors (pink, yellow, and white). Spectrophotometric measurements were made of samples below three different mucosa thicknesses (1 mm, 2 mm, and 3 mm) and titanium served as negative control. Color difference ΔE was calculated using ΔL, Δa, and Δb values for each sample (in total 30 samples). ΔE values were significantly above the threshold value of 3.70 for sand-blasted Ti and Ti-ZrO(2) samples when tested below 1 mm thick soft tissue, hence resulted in a dark appearance of the soft tissues. In contrast, Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples showed significant ΔL values below 1 mm, which indicates a brightening of the covering tissue. In general, ΔE values decreased with increasing thickness of the tissue. At 3 mm thick tissue, ΔE values were significantly below 3.70 for Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples. The preferable substrate surface should be machined due increased color brightness, good soft tissue integration and improved adhesion between coating and substrates. Improvement of the optical appearance of the metal was achieved with the coating systems Ti-Al-ZrO(2) and Ti-Ag-ZrO(2). Darkening effects could not be observed for these systems, and partially light brightening of the tissue was observed. Advantageous colors were suggested to be pink and yellow. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  8. Dental Care in Scleroderma

    Science.gov (United States)

    Dental Care in Scleroderma People living with scleroderma face unique challenges while trying to maintain their oral ... They are more likely to be affected by dental conditions such as small mouth, dry mouth, jaw ...

  9. American Dental Association

    Science.gov (United States)

    ... CE providers and find CE courses. Commission on Dental Accreditation Explore CODA's role and find accredited schools and programs Joint Commission on National Dental Examinations Learn about the examinations used in licensing ...

  10. Diabetes: Dental Tips

    Science.gov (United States)

    Diabetes: Dental Tips For more copies contact: National Institute of Dental and Craniofacial Research National Oral Health Information Clearinghouse ... damage the gum and bone that hold your teeth in place and may lead to painful chewing ...

  11. American Dental Hygienists' Association

    Science.gov (United States)

    ... Now Autumn Giving: ‘Fall’ into the Future of Dental Hygiene Support the Institute for Oral Health! Give ... best for your patients! Learn More Sidebar Menu Dental Hygiene Programs Continuing Education Career Center Annual Conference ...

  12. Dental Effluent Guidelines

    Science.gov (United States)

    Overview and documents for Dental Office Category regulation (40 CFR Part 441); comprising pretreatment standards for discharges of dental amalgam pollutants, including mercury, into publicly owned treatment works (POTWs).

  13. Dental Encounter System (DES)

    Data.gov (United States)

    Department of Veterans Affairs — Dental Encounter System (DES) is an automated health care application designed to capture critical data about the operations of VA Dental Services. Information on...

  14. Dental Caries (Tooth Decay)

    Science.gov (United States)

    ... Materials Contact Us Home Research Data & Statistics Dental Caries (Tooth Decay) Dental caries (tooth decay) remains the most prevalent chronic disease ... adults, even though it is largely preventable. Although caries has significantly decreased for most Americans over the ...

  15. Dental Caries (Tooth Decay)

    Science.gov (United States)

    ... Contact Us Home Research Data & Statistics Share Dental Caries (Tooth Decay) Dental caries (tooth decay) remains the most prevalent chronic disease ... adults, even though it is largely preventable. Although caries has significantly decreased for most Americans over the ...

  16. Measuring the Impact of Cognitive Prosthetics on the Daily Life of People with Dementia and Their Carers

    Science.gov (United States)

    Meiland, Franka; Dröes, Rose-Marie; Sävenstedt, Stefan

    Assistive technologies to support persons with dementia and their carers are used increasingly often. However, little is known about the effectiveness of most assistive devices. Much technology is put on the market without having been properly tested with potential end-users. To increase the chance that an assistive device is well accepted and useful for the target group, it is important, especially in the case of disabled persons, to involve potential users in the development process and to evaluate the impact of using the device on them before implementing it in the daily care and support. When evaluating the impact, decisions have to be made regarding the selection of measuring instruments. Important considerations in the selection process are the underlying domains to be addressed by the assistive technology, the target group and the availability of standardized instruments with good psychometric properties. In this chapter the COGKNOW project is used as a case example to explain how the impact of cognitive prosthetics on the daily lives of people with dementia and their carers can be measured. In COGKNOW a cognitive prosthetic device is being developed to improve the quality of life and autonomy of persons with dementia and to help them to remember and remind, to have social contact, to perform daily activities and to enhance feelings of safety. For all these areas, potential measuring instruments are described. Besides (standardized) measuring instruments, other data collection methods are used as well, such as semi-structured interviews and observations, diaries and in situ measurement. Within the COGKNOW project a first uncontrolled small-scale impact measurement takes place during the development process of the assistive device. However, it is recommended to perform a larger randomized controlled study as soon as the final product is ready to evaluate the impact of the device on persons with dementia and carers before it is released on the market.

  17. Fabrication of an interim complete removable dental prosthesis with an in-office digital light processing three-dimensional printer: A proof-of-concept technique.

    Science.gov (United States)

    Lin, Wei-Shao; Harris, Bryan T; Pellerito, John; Morton, Dean

    2018-04-30

    This report describes a proof of concept for fabricating an interim complete removable dental prosthesis with a digital light processing 3-dimensional (3D) printer. Although an in-office 3D printer can reduce the overall production cost for an interim complete removable dental prosthesis, the process has not been validated with clinical studies. This report provided a preliminary proof of concept in developing a digital workflow for the in-office additively manufactured interim complete removable dental prosthesis. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Initial Clinical Evaluation of the Modular Prosthetic Limb

    Directory of Open Access Journals (Sweden)

    Briana N. Perry

    2018-03-01

    Full Text Available The Modular Prosthetic Limb (MPL was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedback, and individual digit control. The MPL was successfully fit to a 33-year-old with a trans-radial amputation (TR01 and a 30-year-old with a wrist disarticulation amputation (TR02. To preserve anatomical limb length, we adjusted the powered degrees of freedom of wrist motion between users. Motor training began with practicing sEMG and pattern recognition control within the virtual integration environment (VIE. Prosthetic training sessions then allowed participants to complete a variety of activities of daily living with the MPL. Training and Motion Control Accuracy scores quantified their ability to consistently train and execute unique muscle-to-motion contraction patterns. Each user also completed one prosthetic functional metric—the Southampton Hand Assessment Procedure (SHAP for TR01 and the Jebsen-Taylor Hand Function Test (JHFT for TR02. Haptic feedback capabilities were integrated for TR01. TR01 achieved 95% accuracy at 84% of his VIE sessions. He demonstrated improved scores over a year of prosthetic training sessions, ultimately achieving simultaneous control of 13 of the 17 (76% attempted motions. His performance on the SHAP improved from baseline to final assessment with an increase in number of tasks achieved. TR01 also used vibrotactile sensors to successfully discriminate between hard and soft objects being grasped by the MPL hand. TR02 demonstrated 95% accuracy at 79% of his VIE sessions. He demonstrated improved scores over months of prosthetic training sessions, however there was a significant drop in scores initially following a mid

  19. DENTAL SCHOOL PLANNING.

    Science.gov (United States)

    GALAGAN, DONALD J.

    THIS DISCUSSION PRESENTS A COMPLETE PICTURE OF THE CURRENT STATE OF DENTAL EDUCATION WITH SUGGESTIONS FOR MEETING THE DEMANDS FOR DENTAL STAFF AND FACILITIES. THE AREAS INVESTIGATED ARE (1) OBJECTIVES IN DENTAL EDUCATION--COURSES, TEACHING MODES, INNOVATIONS IN CURRICULUM, COORDINATION OF BASIC AND CLINICAL INSTRUCTION, (2) FACILITY…

  20. Stress Among Dental Students

    NARCIS (Netherlands)

    A.M. Alzahem (Abdullah)

    2015-01-01

    markdownabstractAbstract Dental students are facing many stressors in dental education, causing many negative outcomes. The most common are the exams and the clinical requirements. We suggest exposing the dental students to patient care as early as possible in their curriculum. This can help to

  1. Marketing Dental Services | Tuominen | Tanzania Dental Journal

    African Journals Online (AJOL)

    Tanzania Dental Journal. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 1 (2000) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Marketing Dental Services. R Tuominen. Abstract. No Abstract.

  2. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  3. Antibiotics prescription in Nigerian dental healthcare services.

    Science.gov (United States)

    Azodo, C C; Ojehanon, P I

    2014-09-01

    Inappropriate antibiotics prescription in dental healthcare delivery that may result in the emergence of antibiotic-resistant bacteria, is a worldwide concern. The objective of the study was to determine the antibiotics knowledge and prescription patterns among dentists in Nigeria. A total of 160 questionnaires were distributed to dentists attending continuing education courses organized by two organizations in Southern and Northern parts of Nigeria. Data analysis was done using SPSS version 17.0. A total of 146 questionnaires were returned, properly filled, out of 160 questionnaires, giving an overall response rate 91.3%. The clinical factors predominantly influenced the choice of therapeutic antibiotics among the respondents. In this study, the most commonly prescribed antibiotics among the respondents was a combination of amoxicillin and metronidazole. Of the respondents, 136 (93.2%) of them considered antibiotic resistance as a major problem in Nigeria and 102 (69.9%) have experienced antibiotics resistance in dental practice. The major reported conditions for prophylactic antibiotics among the respondents were diabetic mellitus, HIV/AIDS, history of rheumatic fever, other heart anomalies presenting with heart murmur and presence of prosthetic hip. The knowledge of adverse effects of antibiotics was greatest for tooth discoloration which is related to tetracycline. Data from this study revealed the most commonly prescribed antibiotics as a combination of amoxicillin and metronidazole. There existed gaps in prophylactic antibiotic prescription, consideration in the choice of therapeutic antibiotics and knowledge of adverse effects of antibiotics among the studied dentists.

  4. Dental therapeutic systems.

    Science.gov (United States)

    Iqbal, Zeenat; Jain, Nilu; Jain, Gaurav K; Talegaonkar, Sushama; Ahuja, Alka; Khar, Roop K; Ahmad, Farhan J

    2008-01-01

    The recognition of periodontal diseases as amenable to local antibiotherapy has resulted in a paradigmatic shift in treatment modalities of dental afflictions. Moreover the presence of antimicrobial resistance, surfacing of untoward reactions owing to systemic consumption of antibiotics has further advocated the use of local delivery of physiologically active substances into the periodontal pocket. While antimicrobials polymerized into acrylic strips, incorporated into biodegradable collagen and hollow permeable cellulose acetate fibers, multiparticulate systems, bio-absorbable dental materials, biodegradable gels/ointments, injectables, mucoadhesive microcapsules and nanospheres will be more amenable for direct placement into the periodontal pockets the lozenges, buccoadhesive tablets, discs or gels could be effectively used to mitigate the overall gingival inflammation. Whilst effecting controlled local delivery of a few milligram of an antibacterial agent within the gingival crevicular fluid for a longer period of time, maintaining therapeutic concentrations such delivery devices will circumvent all adverse effects to non- oral sites. Since the pioneering efforts of Goodson and Lindhe in 1989, delivery at gingival and subgingival sites has witnessed a considerable progress. The interest in locally active systems is evident from the patents being filed and granted. The present article shall dwell in reviewing the recent approaches being proffered in the field. Patents as by Shefer, et al. US patent, 6589562 dealing with multicomponent biodegradable bioadhesive controlled release system for oral care products, Lee, et al. 2001, US patent 6193994, encompassing a locally administrable, biodegradable and sustained-release pharmaceutical composition for periodontitis and process for preparation thereof and method of treating periodontal disease as suggested by Basara in 2004via US patent 6830757, shall be the types of intellectual property reviewed and presented in

  5. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  6. Customized mold radiotherapy with prosthetic apparatus for oral cancers

    International Nuclear Information System (INIS)

    Noguchi, Tadahide; Tsuchiya, Yoshiyuki; Hayasaka, Junichi; Itoh, Hiroto; Jinbu, Yoshinori; Kusama, Mikio; Takahashi, Satoru; Nakazawa, Masanori

    2014-01-01

    Eight patients (6 males, 2 females; median age, 78 years; age range, 31-94 years) were treated by mold radiotherapy with a prosthetic apparatus for oral cancers between October 2006 and March 2013. The primary sites were the tongue in 3 cases, hard palate and buccal mucosa in 2 cases each, and oral floor in 1 case. The type of treatment consisted of radical radiotherapy and palliative radiotherapy in 2 cases each, and preoperative radiotherapy, postoperative radiotherapy, additional radiotherapy after external beam radiotherapy and systemic chemotherapy in 1 case each. Patients received 40-50 Gy in 8-10 fractions with mold radiotherapy. Two patients who received radical radiotherapy showed no signs of recurrence or metastasis. The present therapy contributed to patients' palliative, postoperative, and preoperative therapy. Mold radiotherapy with a prosthetic appliance was performed safely and was a useful treatment for several types of oral cancer. (author)

  7. Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Stefano Artiaco

    2013-01-01

    Full Text Available Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty infection, causing a large inflammatory pseudotumor of the hip joint. Fungal periprosthetic joint infections are a rare clinical entity and difficult to diagnose, and a pseudotumor may be part of their clinical presentation. They should be suspected in immunodeficient host patients when clinical symptoms of prosthetic joint infections are observed.

  8. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the temporomandibular...

  9. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    Science.gov (United States)

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. © 2014 Blackwell Verlag GmbH.

  10. A novel polymeric prosthetic heart valve: design, manufacture, and testing

    OpenAIRE

    Brubert, Jacob

    2016-01-01

    In this thesis a flexible leaflet polymeric prosthetic aortic heart valve was designed, manufactured, and tested. The prosthesis was designed with the aim of overcoming the need for anticoagulant therapy, which is required for current mechanical prostheses; while also having lifelong durability, which current bioprosthetic heart valves are not able to achieve. Inspired by the anisotropic architecture of collagen in the natural valve, a shortlist of polystyrene based block copolymers (BCPs), w...

  11. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal

    OpenAIRE

    Nikola Džakula; Josip Kranjčić; Denis Vojvodić

    2016-01-01

    The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The tw...

  13. Indium-111 leukocyte localization in infected prosthetic graft

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V. (Univ. of Arkansas for Medical Sciences, Little Rock (USA))

    1990-08-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection.

  14. Indium-111 leukocyte localization in infected prosthetic graft

    International Nuclear Information System (INIS)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V.

    1990-01-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection

  15. Factors influencing the cost of prosthetic joint infection treatment.

    Science.gov (United States)

    Peel, T N; Cheng, A C; Lorenzo, Y P; Kong, D C M; Buising, K L; Choong, P F M

    2013-11-01

    Prosthetic joint infection (PJI) is associated with significant costs to the healthcare system. Current literature examines the cost of specific treatment modalities without assessing other cost drivers for PJI. To examine the overall cost of the treatment of PJI and to identify factors associated with management costs. The costs of treatment of prosthetic joint infections were examined in 139 patients across 10 hospitals over a 3-year period (January 2006 to December 2008). Cost calculations included hospitalization costs, surgical costs, hospital-in-the-home costs and antibiotic therapy costs. Negative binomial regression analysis was performed to model factors associated with total cost. The median cost of treating prosthetic joint infection per patient was Australian $34,800 (interquartile range: 20,305, 56,929). The following factors were associated with increased treatment costs: septic revision arthroplasty (67% increase in treatment cost; P = 0.02), hypotension at presentation (70% increase; P = 0.03), polymicrobial infections (41% increase; P = 0.009), surgical treatment with one-stage exchange (100% increase; P = 0.002) or resection arthroplasty (48% increase; P = 0.001) were independently associated with increased treatment costs. Culture-negative prosthetic joint infections were associated with decreased costs (29% decrease in treatment cost; P = 0.047). Treatment failure was associated with 156% increase in treatment costs. This study identifies clinically important factors influencing treatment costs that may be of relevance to policy-makers, particularly in the setting of hospital reimbursement and guiding future research into cost-effective preventive strategies. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  17. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  18. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  19. Overview: Mechanism and Control of a Prosthetic Arm.

    Science.gov (United States)

    Kulkarni, Tushar; Uddanwadiker, Rashmi

    2015-09-01

    Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.

  20. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    Science.gov (United States)

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  1. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  3. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  4. Ergonomic workplace assessment in orthotic and prosthetic workshops.

    Science.gov (United States)

    Salmani Nodooshan, H; Koohi Booshehri, S; Daneshmandi, H; Choobineh, A R

    2016-10-17

    In Iranian orthotic and prosthetic workshops, the majority of activities are carried out by manpower and the tasks are labor-intensive. In these workshops, ergonomic aspects of working conditions are seldom considered. This study was conducted in orthotic and prosthetic workshops with the objectives of determination of prevalence rate of MSDs among employees and assessment of ergonomics working conditions. In this cross-sectional study, all employees (n = 42; 29 males and 13 females) in 11 active orthotic and prosthetic production centers of Shiraz city participated. Data were collected using Nordic Musculoskeletal disorders Questionnaire (NMQ) and observational technique by an ergonomics checklist for assessment of working conditions. The means (SD) of age and job tenure (years) in the study individuals were 37.26 (10.21) and 12.8 (9.39), respectively. The most prevalent MSD symptoms in the past 12 months were reported in the lower back (42.9%), shoulders (40.5%) and knees (40.5%). Working conditions assessment showed that the main ergonomic problems in the workshops studied originated from awkward working posture, improper workstation design, poorly designed hand tools and incorrect manual material handling. Any interventional program for working conditions improvement should, therefore, focus on these areas.

  5. Prosthetic Leg Control in the Nullspace of Human Interaction.

    Science.gov (United States)

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  6. In vitro adherence of bacteria to prosthetic grafting materials

    International Nuclear Information System (INIS)

    Brewer, A.R.; Stromberg, B.V.

    1990-01-01

    Adherence of bacteria to prosthetic grafting material is thought to play an important role in the ultimate development of prosthetic infections. To evaluate the role of bacterial adherence in the initiation and colonization of prosthetic materials, Proplast II, Gore-Tex, and silicone were evaluated for adherence of Escherichia coli and Staphylococcus aureus. Bacteria were radiolabeled and incubated with the study material. Adherence was determined by scintillation. Adherence to Proplast II and Gore-Tex reached a maximum at approximately 45 minutes of incubation and demonstrated a detachment phenomenon with E. coli. Similar results were noted with S. aureus, but with a maximal attachment at approximately 30 minutes. Interestingly, bacterial attachment to silicone continued to increase throughout the time of the incubation. In addition, adherence of S. aureus was at a faster rate than E. coli. Attachment of bacteria is a multifactorial process. However, the PTFE graft demonstrates a slower rate of attachment, lower total number of attached bacteria, and faster detachment. The importance of this phenomenon may help explain the foreign body effect of increased susceptibility to infection of foreign materials

  7. Dental education in Peru.

    Science.gov (United States)

    Komabayashi, Takashi; Sato, Manuel; Rodiguez, Lyly; Sato, Doris; Bird, William F

    2008-09-01

    This paper provides information about Peru's dental history and dental school system, including the curriculum and dental licensure. With the increase in the number of dental schools in Peru, the number of dentists is also increasing. Until 1965, Peru had only three dental schools; currently, there are 14. Four of these dental schools are public, and ten are private. A five- or six-year dental program leads to the B.D.S. degree. After successful completion of a thesis defense or competency examination, the D.D.S. degree is awarded. The D.D.S. is mandatory for practicing dentistry in Peru. Currently, there are approximately 14,000 active dentists, with a dentist-patient ratio of approximately 1:2,000.

  8. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  9. Pilot Study on the Influence of Nutritional Counselling and Implant Therapy on the Nutritional Status in Dentally Compromised Patients

    Science.gov (United States)

    Wöstmann, Bernd; Simon, Teresa; Neuhäuser-Berthold, Monika; Rehmann, Peter

    2016-01-01

    Objectives To investigate the impact of implant-prosthetic rehabilitation combined with nutritional counseling on the nutritional status of patients with severely reduced dentitions. Design An explorative intervention study including an intra-individual comparison of 20 patients with severely reduced dentitions in terms of nutrition- and quality of life-related parameters recorded at baseline and at six and twelve months after implant-prosthetic rehabilitation. Participants Twenty patients from the Department of Prosthetic Dentistry of Justus-Liebig University of Giessen, with an mean age of 63 years, who had fewer than ten pairs of antagonists. Measurements The baseline data collection included dental status, a chewing ability test, laboratory parameters, anthropometric data (body mass index), energy supply, a 3-day dietary record, an analysis of the oral health-related quality of life (OHRQoL) with the OHIP-G14, the Mini-Mental Status (MMS) and Mini Nutritional Assessment (MNA). Six months after implantation and prosthetic rehabilitation, individual nutritional counseling was performed by a dietician. Data were again collected and analyzed. A final follow-up was conducted 12 months after prosthetic rehabilitation. Results Despite the highly significant improvement in masticatory ability and OHRQoL after implant-prosthetic rehabilitation, no significant changes were observed regarding MNA, anthropometric data or energy supply. Except for cholinesterase (p = 0.012), ferritin (p = 0.003), folic acid (p = 0.019) and vitamin A (p = 0.004), no laboratory parameter changed significantly during the investigation period. In addition, no general significant differences were observed for nutrient intake or food choice. Conclusion The present study does not confirm the assumption that the implant-prosthetic rehabilitation of patients with severely reduced residual dentitions with or without an individual nutritional counseling influences nutritional status. PMID:26821352

  10. Description and Documentation of the Dental School Dental Delivery System.

    Science.gov (United States)

    Chase, Rosen and Wallace, Inc., Alexandria, VA.

    A study was undertaken to describe and document the dental school dental delivery system using an integrated systems approach. In late 1976 and early 1977, a team of systems analysts and dental consultants visited three dental schools to observe the delivery of dental services and patient flow and to interview administrative staff and faculty.…

  11. Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.

    Science.gov (United States)

    Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T

    2000-04-01

    Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.

  12. Current antibiotic management of prosthetic joint infections in Italy: the 'Udine strategy'.

    Science.gov (United States)

    Bassetti, Matteo; Cadeo, Barbara; Villa, Giovanni; Sartor, Assunta; Cainero, Vanni; Causero, Araldo

    2014-09-01

    The rate of prosthetic joint infections followed and cured at our institution is constantly increasing, in line with epidemiological data from the recent literature. This is probably related to the greater number of knee and hip prostheses implanted every year. For intermediate and late infections, only the two-stage approach is applied, as this demonstrates the best outcome in our experience. Particular attention is paid to microbiological isolation of the pathogen: multiple samples of tissue are collected during the interventions, and kept in culture for a longer period of time than usual. Sonication of prosthetic devices is used to enhance the sensitivity and specificity of the microbiological cultures. Histological examination influences surgical choices either towards implantation of a new prosthesis or replacement of the spacer. An empirical antibiotic backbone of a glycopeptide/lipopeptide and rifampicin is chosen, due to the leading role of Gram-positive bacteria in this setting and the high incidence of methicillin resistance in our centre (>30%), followed by an antibiotic regimen containing linezolid. If specific risk factors are present, an anti-Gram-negative drug is added to the regimen. Duration of therapy depends upon the approach that is chosen, usually being 6 weeks when the prosthesis is removed. Despite at the moment being limited by its small sample size, data from our experience confirms that our empirical approach may represent a valid choice during the early phase of treatment, by keeping linezolid for a step-down therapy of shorter duration (4 weeks). © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. A Prosthetic Hand Body Area Controller Based on Efficient Pattern Recognition Control Strategies.

    Science.gov (United States)

    Benatti, Simone; Milosevic, Bojan; Farella, Elisabetta; Gruppioni, Emanuele; Benini, Luca

    2017-04-15

    Poliarticulated prosthetic hands represent a powerful tool to restore functionality and improve quality of life for upper limb amputees. Such devices offer, on the same wearable node, sensing and actuation capabilities, which are not equally supported by natural interaction and control strategies. The control in state-of-the-art solutions is still performed mainly through complex encoding of gestures in bursts of contractions of the residual forearm muscles, resulting in a non-intuitive Human-Machine Interface (HMI). Recent research efforts explore the use of myoelectric gesture recognition for innovative interaction solutions, however there persists a considerable gap between research evaluation and implementation into successful complete systems. In this paper, we present the design of a wearable prosthetic hand controller, based on intuitive gesture recognition and a custom control strategy. The wearable node directly actuates a poliarticulated hand and wirelessly interacts with a personal gateway (i.e., a smartphone) for the training and personalization of the recognition algorithm. Through the whole system development, we address the challenge of integrating an efficient embedded gesture classifier with a control strategy tailored for an intuitive interaction between the user and the prosthesis. We demonstrate that this combined approach outperforms systems based on mere pattern recognition, since they target the accuracy of a classification algorithm rather than the control of a gesture. The system was fully implemented, tested on healthy and amputee subjects and compared against benchmark repositories. The proposed approach achieves an error rate of 1.6% in the end-to-end real time control of commonly used hand gestures, while complying with the power and performance budget of a low-cost microcontroller.

  14. A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations

    Science.gov (United States)

    2017-09-01

    mobility, prosthetic foot preference and walking ability after two weeks of use in the home and community setting. No exclusions based on sex , race...2012 Page 17 of 33 Data collection Photos and video recording With the participant’s explicit consent, we may take video and photos during portions of...this study, for documentation and use in research publications. All videos and photos will exclue the participant’s face and identifying marks will

  15. A survey of prosthetic eye wearers to investigate mucoid discharge

    Directory of Open Access Journals (Sweden)

    Pine K

    2012-05-01

    Full Text Available Keith Pine1, Brian Sloan2, Joanna Stewart3, Robert J Jacobs11Department of Optometry and Vision Science, 2Department of Ophthalmology, New Zealand National Eye Centre, 3Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New ZealandBackground: This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients.Methods: An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists’ Web sites containing comments on the cause and treatment of discharge were surveyed.Results: Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists’ Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes.Conclusions: A standardized treatment

  16. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    Science.gov (United States)

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  17. Production of radioiodinated prosthetic group for indirect protein labeling

    International Nuclear Information System (INIS)

    Santos, Josefina da Silva

    2001-01-01

    Monoclonal antibodies and their fragments and, more recently, radiolabeled peptides have been extensively studied in order to develop radiopharmaceuticals for diagnostic and therapy in Nuclear Medicine. The radioiodination of proteins can be done by a direct method, with radioiodine being incorporated in to a tyrosine residue of the protein by electrophilic substitution. The main problem in the use of radioiodinated proteins, is that they are often dehalogenated in vivo by the action of specific enzymes, probably because of the structural similarity between iodophenyl groups and thyroid hormones. Several protein radioiodination methods have been developed in order to minimize this in vivo dehalogenation using prosthetic groups for indirect labeling. In this case, the radioiodine is first incorporated in to the prosthetic group that is subsequently attached to a terminal amino group or to a ε-amino group of lysine residue. The aim of this work is to obtain a radioiodinated prosthetic group for indirect labeling of proteins. The prosthetic group selected was the N-succinimidyl-4-radioiodine benzoate (SIB), obtained by the iodination of the p-bromobenzoic acid followed by the reaction with TSTU (0-(N-succinimidyl)-N,N,N',N'-tetramethyl uronium tetrafluoroborate) The results of these studies showed that the p-radio iodobenzoic acid was obtained with a radiochemical purity greater than 92% and a labeling yield of about 65%. Some reaction parameters were studied like temperature, time and Cu Cl mass (cataliser). The SIB was quantitatively obtained from p-radio iodobenzoic acid, using basic medium and after removing the water from the reaction using an nitrogen stream. The kinetic of this reaction is very fast with complete consumption of the p-radioiodebenzoic acid after 5 minutes. The coupling of the SIB prosthetic group to the protein was studied using Human Immunoglobulin (IgG) as a protein model. In a comparative way, the same protein was used on direct labeling

  18. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    OpenAIRE

    Andrii Biben; Zinovii Ozhohan

    2017-01-01

    The objective of the research was to evaluate the clinical effectiveness of using aesthetic fixed prosthetic appliances with combined occlusal surface. Materials and methods. The study included 30 patients who were divided into 2 groups: Group I included 20 patients with combined occlusal surface of the crowns; Group II included 22 patients with ceramic occlusal surface of the crowns. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. 6 months after prosthet...

  19. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  20. Optical investigations of various polymeric materials used in dental technology

    Science.gov (United States)

    Negrutiu, Meda Lavinia; Sinescu, Cosmin; Topala, Florin Ionel; Ionita, Ciprian; Goguta, Luciana; Marcauteanu, Corina; Rominu, Mihai; Podoleanu, Adrian Gh.

    2011-10-01

    Dental prosthetic restorations have to satisfy high stress as well as aesthetic requirements. In order to avoid deficiencies of dental prostheses, several alternative systems and procedures were imagined, directly related to the material used and also to the manufacturing technology. Increasing the biomechanical comportment of polymeric materials implies fiber reinforcing. The different fibers reinforcing products made very difficult the evaluation of their performances and biomechanical properties analysis. There are several known methods which are used to assess the quality of dental prostheses, but most are invasive. These lead to the destruction of the samples and often no conclusion could be drawn in the investigated areas of interest. Using a time domain en-face OCT system, we have recently demonstrated real time thorough evaluation of quality of various dental treatments. The aim of this study was to assess the quality of various polymeric materials used in dental technology and to validate the en face OCT imagistic evaluation of polymeric dental prostheses by using scanning electron microscopy (SEM) and microcomputer tomography (μCT). SEM investigations evidenced the nonlinear aspect of the interface between the polymeric material and the fiber reinforcement and materials defects in some samples. The results obtained by microCT revealed also some defects inside the polymeric materials and at the interfaces with the fiber reinforcement. The advantages of the OCT method consist in non-invasiveness and high resolution. In addition, en face OCT investigations permit visualization of the more complex stratified structure at the interface between the polymeric material and the fiber reinforcement.